As part of this process you are responsible for:

Size: px
Start display at page:

Download "As part of this process you are responsible for:"

Transcription

1 Section 104 application for the adoption of a new sewer The process In order to progress a sewer for adoption you are required to complete the application form following the principles set out in the current Sewers for Adoption guide. You must ensure that your application adequately explains your proposals and that all the relevant information listed on the form is provided. You are also required to complete an application to connect to the public sewer for your proposed adoptable sewer. The completed application form and associated information/drawings will be used to technically assess your application and to prepare the Section 104 adoption agreement. As part of this process you are responsible for: Designing the sewerage system to comply with the current edition of Sewers for Adoption and the Anglian Water additions and deletions document for pumping stations. Obtaining permissions and consents for surface water discharge, including deed or grant of easement for discharge to watercourses. Obtaining easements to construct adoptable sewers in land which is outside of your ownership. Providing all the relevant information that we require to complete the design check. Entering into a Section 104 adoption agreement before work commences on site. Constructing, at your expense the approved adoptable sewerage system. Providing facilities to allow Anglian Water to inspect the adoptable sewerage system on site. Ensuing that your chosen contractor completes and submits to Anglian Water the attached method statement for all direct connections to the public sewer. Consulting Anglian Water regarding any proposed design changes. Ensuring compliance with the Confined Spaces Regulations Paying the upfront fee with the application and the remainder of the 2.5% estimated cost at the appropriate time. Paying zonal charges for each premises connecting to water and/or sewerage services for the first time. Providing accurate as constructed information for the adoptable sewerage system. Maintaining the adoptable sewerage system until such time as adoption takes place. Providing a financial surety, in the form of bank guarantee or a cash deposit during the period of the agreement. Where an adoptable pumping station is constructed you are responsible for transferring the appropriate land into the ownership of Anglian Water and for acquiring the appropriate rights of access for Anglian Water. Section 104 application for the adoption of a new sewer The process

2 As part of the process we are responsible for: Assessing and approving your design and providing assistance with your application. Preparing an estimate for the cost of the adoptable sewerage system to enable the fees and the limit of the financial surety to be determined. Preparing and providing you with the formal offer of a Section 104 adoption agreement. Preparing the Section 104 adoption agreement. Undertaking the inspection of the adoptable sewerage works on site. Assessing and providing feedback regarding any proposed design changes and providing our approval where appropriate. Issuing a permit to enter for all Anglian Water confined spaces. Certifying the completeness of the adoptable sewerage works at the appropriate times. Adopting the sewerage system and operating and maintaining the same after adoption has taken place. Notifying the appropriate bodies regarding the status of the agreement as required. Completion of the method statement for a direct connection to the public sewer. Your are required to submit a sewer connection application form under Section 106 of the Water Industry Act 1991 together with your Section 104 adoption application form. This should identify the total number of direct connections to be made to the public sewer and your contractor is required to complete a method statement for each of these. A method statement form and guidance for contractors is available to download on Anglian Water s website. Payment of the Technical Vetting and Administration Fee (TVA) with your application to connect to the public sewer. As stipulated above you are required to make an application to connect to the public sewer and to pay the TVA. The value of the payment required is dependent upon whether the proposed connection is direct or indirect. If you are proposing to connect to the existing public sewer, you are required to pay the direct TVA; however, if you are proposing to connect to an existing private sewer you are required to pay the indirect TVA. If the sewer you propose to connect to is under your ownership or the ownership of another developer and is or will be subject to a Section 104 Adoption Agreement, the connection is considered to be indirect and the indirect TVA is payable. Section 104 application for the adoption of a new sewer The process

3 Notification number (Anglian Water use only) Application for the adoption of a new sewer This form should be used by the developer and/or the planning supervisor to apply for an agreement to adopt a new sewer under Section 104 of the Water Industry Act Please note that there is an upfront deposit required with this application as shown in Section 5 of this form. Payment can be made by either cheque, payable to: 'Anglian Water Services Ltd' or by credit or debit card by calling us on , option 4, option 1. Please fully complete all sections of the form in BLOCK CAPITALS Section 1 - Applicant and sewer details 1a Company name: For the attention of: Property name/number: Mobile number: address: 1b About you: Developer Landowner Acting on behalf of developer/landowner 1c Will you require more than one Section 104 agreement for the sewers covered by this application? No 1d Type of system offered for adoption: Foul water: No Surface water: No Combined: No Vacuum: No 1e Landowner (if different to 1a) SuDS: * No * If you have ticked '' to SuDS, we will require you to send in two separate sets of design details; one for the foul design and one for the SuDS design. Landowner name: Property name/number: 1f Developer (if different to 1a) Company name: Property name/number: Section 2 - Location of new sewer 2a Site address: Contact: (if different from applicant) Site name: For the attention of: Address: Mobile number: address: 2b Local Authority:

4 Section 3 - Details to be provided for a sewer adoption agreement 3a Information that MUST be supplied to progress vetting (please tick) i) Location plan, 2 copies, 1:2500 scale. ii) Site layout, 2 copies detailing site boundary, road, sewers (coloured as per appendix vi of the current Sewers for Adoption guide), pumping stations and rising mains (if any), including compound, road gullies/highway, drains, water courses and site contours. iii) Drainage area plan, 2 copies showing existing and proposed drainage details (incl. all private drains). iv) Longitudinal sections (sewers and rising mains), 2 copies 1:500 horizontal by 1:100 vertical, showing levels, proposed cover and invert levels, pipe material, pipe strength, pipe diameters, bedding classification and details, air valves and washout. v) Do you intend to use our 'standard adoptable sewerage detail'? No vi) Construction details, 2 copies detailing manholes, pumping station and manhole schedules. To include a declaration on the drawings that all work will comply with the current Sewers for Adoption guide and any Anglian Water amendments to that document. vii) Hydraulic design calculations, foul and surface water, including impermeable area plan*, and design parameters. *The coloured impermeable area plan should clearly show and state the area drained to each length of adoptable suface water sewer. viii) Pumping station information (if required), 2 copies scale 1:20 or 1:50 showing general arrangement details, wet well capacity/storage/time to spillage, rising main capacity, surge calculations, structural calculations and drawings, flotation check. ix) A hard copy of the planning permission and associated conditions. x) Authorising body's proof of approval to discharge surface water. xi) Sewer connection application form. Please supply the following information as soon as available: xii) Evidence of title to all the land through which sewers will be constructed. xiii) Utility drawings for all existing and proposed apparatus. xiv) Ground investigation report. xv) Landscaping drawing. xvi) Other information that may be relevant to Anglian Water in assessing this site. Section 4 - Site details 4a CDM Coordinator Name: Signature: Contact numbers: 4b Principal contractor Contractor name: Property name/number: 4c Please indicate the total number of dwellings/units to be constructed and your period of construction. (Please mark on site plan any proposed phasing). i) Total number of dwellings to be constructed : ii) Period of construction for drainage:

5 Section 5 - Declaration 5a i) ii) iii) By signing this declaration I can confirm that: I wish to apply for a sewer adoption agreement under Section 104 of the Water Industry Act In making this application I agree to pay the standard section 104 fee, which will be 2.5% of the estimated construction cost of the approved design. I acknowledge that part of this fee, listed below, is non-refundable to cover our vetting costs should a section 104 agreement not be entered into. In addition, I agree to pay Anglian Water s connection charges for connecting the new sewer and associated premises to the existing network for the first time, including sewerage zonal charges, where appropriate. I acknowledge that the upfront deposit required with this application is part payment based on the table below. I attach a cheque, payable to 'Anglian Water Services Ltd', for I have made a payment by credit/debit card for Date of payment: Payment reference no: Size of development Foul only Surface Water and/or SuDS Foul and surface water and/or SuDs Up to 50 plots plots 1, , , plus plots 1, , , b i) ii) OWNER: (delete as appropriate) I confirm that I am the owner/occupier of the address to be connected (Section 2) and that: The applicant has approval to act exclusively on my behalf in dealing with Anglian Water regarding the connection to the public sewer at the site. I will pay any charges as per 5a ii) & iii) Print name: Signature: 5c i) ii) APPLICANT: (delete as appropriate) I confirm that I am the applicant acting on behalf of the owner/occupier and that: The owner/occupier will pay any charges as per 5a ii) & iii)* I will pay any charges as per 5a ii & iii)* *delete as appropriate Print name: Company: Signature: Position in company: Date: Please return your completed application form with your payment and all details listed in section 3 by either: Post to: Anglian Water, Developer Services, PO Box 495, Huntingdon, PE29 6YY or to: dsincome@anglianwater.co.uk If you have any questions about this form, please call (Option 3) or developerservices@anglianwater.co.uk For Anglian Water use only Date application received: Upfront deposit paid: No Cheque: Value Chq No: Credit/debit card: Value Reference: BACS: Value Reference: Date payment received: Date payment processed: Processed by: Doc number: Date sent to Drainage Team: Form ref: S104/5/18

6 STANDARD ASSESSMENT CHECKLIST Engineer: Site: Technical Vetting Response No: Our Ref: Developer: SFA6 Compliant Layout Foul Surface Comments Sewer Location Adoptable sewers are laid in Adoptable / Public Highway and/or Public-Open-Space? NB: Sewers serving <10 properties can be located within front gardens if 3m clearance is maintained from buildings Kerb Lines Sewers and manholes are positioned a suitable distance from the kerbline? Sewers are 1m, and manholes are 0.5m, from outside edge to the kerbline Tree Positioning Tree and Landscaping proposals have been submitted and do they comply with our restrictions on planting adjacent to adoptable and/or existing public sewers? Distance to Buildings No buildings should be erected within the protection strip for any existing and/or adoptable public sewers. NB: Size of protection strip stipulated in SFA6. Other Y/N Y/N Y/N Requirement SFA6 Compliant Manholes Foul Surface Comments Manholes are required at all changes in direction, pipe diameter, gradient and where 2 or more sewers connect. Distance between manholes should not exceed 100m Types Appropriate MH Types have been used and detailed? NB: MH Types A, B, C & E permitted. Where manhole depth >6m a special manhole detail will be required Diameters Manhole diameters (Type A & B only) are in accordance with Table 2.2 of SFA6 and take into account minimum benching requirements Covers & Frames Manhole covers and frames are in accordance with Clause of SFA6 and badged 'FW' or 'SW' Rocker Pipes Rocker pipes lengths are in accordance with Table 5.14 of SFA Backdrops Steeper gradients are preferred to the use of backdrops. If required then they should be constructed as external ramped backdrops as per Figure 2.10 in SFA Access / Fittings Minimum access opening sizes and fitting requirements are in accordance with Table 2.3 of SFA6. Other

7 SFA6 Compliant Sewers Foul Surface Comments Depths Do the adoptable sewers have 1.2m cover and if not are the measures taken to protect them in accordance with Table 2.4 of SFA Hydraulic Design - Foul Do sewers achieve a velocity of 0.75m/s at 1/3 design flow? If not, do the gradients satisfy criteria in SFA6? i.e. 100mm dia 2-9 properties connected at 1/80 or 150mm dia >10 properties connected at 1/150. (150mm dia 2-9 properties connected at 1/60 also acceptable) Hydraulic Design - Surface The system does not flood any part of the site in a 1in30 year return period Attenuation Storage for the 1in30 year event is wholly contained within the adoptable system. Storage above the 1in30 year event is private or flood routing provided Surcharging All sewers are designed to run pipe full in a 1in30 year event Bedding The appropriate pipe bedding details have been provided which in most cases would be a Class 'S' bed and surround. Other

8 SFA6 Compliant General Foul Surface Comments Colouring Drawings are coloured as per Appendix VI of SFA6 with highway drains and private laterals uncoloured. Inconsistencies Pipe lengths, gradients and sizes are consistent on layout plans, long sections and design calculations. Long Sections Long section drawings also include bedding details, concrete protection (where applicable), manhole types and manhole diameters Outfalls/Headwalls A detail of the outfall/headwall has been provided and is in accordance with Fig 2.1 and 2.2 of SFA6 which includes water levels Flow control device The relevant head/flow characteristics curve and installation details been provided? Impermeable Area Plan A coloured impermeable area plan has been provided identifying areas discharging to each pipe line. Private Connections Private connections to the adoptable sewers are a minimum 100mm diameter and laid soffit to soffit Connection to the Public Sewer The existing levels of the public sewer and positions of other utility apparatus have been established. Other No works should commence on the adoptable sewerage system until Anglian Water has confirmed compliance with SFA6. SFA6 Compliance Met: Date: / /

Application for adoption of new sewers

Application for adoption of new sewers Application for adoption of new sewers Section 104 WIA 1991 This form should be used to offer proposed drainage systems for adoption by United Utilities under Section 104 of the Water Industry Act 1991.

More information

Developer Services. Building over or near a sewer. DEV 005G Guidance notes and procedure. What is a public sewer?

Developer Services. Building over or near a sewer. DEV 005G Guidance notes and procedure. What is a public sewer? Developer Services DEV 005G Guidance notes and procedure Building over or near a sewer If you are thinking of building a structure (for example, a new building, extension, conservatory, garage etc.) you

More information

New connection to a public sewer

New connection to a public sewer New connection to a public sewer Application form You can go to our website thameswater.co.uk/buildover and apply online or complete this form and return to Thames Water, Developer Services, Clearwater

More information

Building over or close to a public sewer

Building over or close to a public sewer Building over or close to a public sewer Place holder image thameswater.co.uk/developerservices Building over or close to a public sewer Did you know Thames Water is legally responsible for more than 100,000

More information

Application Pack 5. How to apply for a Connection to a Public Sewer/Lateral Drain

Application Pack 5. How to apply for a Connection to a Public Sewer/Lateral Drain Application Pack 5 How to apply for a Connection to a Public Sewer/Lateral Drain Guidance Notes The provisions of the Water Industry Act 1991 (WIA91) take precedence over these notes. We recommend that

More information

New Connections Charging. 1 April 2018 to 31 March 2019

New Connections Charging. 1 April 2018 to 31 March 2019 New Connections Charging 1 April 2018 to 31 March 2019 About this document This Charging Arrangement Document is relevant to all of our customers and defines the way that Severn Trent will charge for all

More information

Water and Sewer connections application form. Section 1. 1a. Applicant details

Water and Sewer connections application form. Section 1. 1a. Applicant details Water and Sewer connections application form Application for new connections to the existing water and/or sewer network. Please use this application to apply for a new water connection(s) and/or sewer

More information

East Ayrshire Council

East Ayrshire Council East Ayrshire Council Construction Consent Checklist (CC9) Developer. Scheme Submitted Drawings East Ayrshire Council 1 CC1 Number(s) Completed correctly?........ Signed by Applicant, not agent?... CC2

More information

Procedure and Specification for the Construction of Vehicle Access Crossings over Footways and Verges April 2016

Procedure and Specification for the Construction of Vehicle Access Crossings over Footways and Verges April 2016 Procedure and Specification for the Construction of Vehicle Access Crossings over Footways and Verges April 2016 (1) Authorisation to work in the Highway Persons wishing to construct a vehicular crossing

More information

Sewer Audit - Design Checklist Gravity sewers, sewage pumping stations and pressure sewers

Sewer Audit - Design Checklist Gravity sewers, sewage pumping stations and pressure sewers Question Relevant Clauses Design checked? Do the drawings show an appropriate revision history, and is 1.1 the design complete, checked and effectively ready for construction? 1.2 Has the whole catchment

More information

Charging Arrangements for New Connection Services

Charging Arrangements for New Connection Services Charging Arrangements for New Connection Services 2018-2019 About South East Water Developer Services Developer Services Department For any new connections requests or issues please contact our Developer

More information

IDAS form 6 Building or operational work assessable against a planning scheme

IDAS form 6 Building or operational work assessable against a planning scheme IDAS form 6 Building or operational work assessable against a planning scheme (Sustainable Planning Act 2009 version 2.0 effective 17 December 2012) This form must be used for development applications

More information

IDAS form 6 Building or operational work assessable against a planning scheme

IDAS form 6 Building or operational work assessable against a planning scheme (Sustainable Planning Act 2009 version 3.0 effective 1 July 2013) This form must be used for development applications for building work or operational work assessable against a planning scheme. You MUST

More information

PALMERSTON NORTH CITY PALMERSTON NORTH STORMWATER DRAINAGE BYLAW. Administration Manual

PALMERSTON NORTH CITY PALMERSTON NORTH STORMWATER DRAINAGE BYLAW. Administration Manual PALMERSTON NORTH CITY PALMERSTON NORTH STORMWATER DRAINAGE BYLAW 2015 Administration Manual 1 Contents Part One Introduction... 4 Part Two Standard Conditions For Stormwater Connections... 5 Appendix 1

More information

Application form AWS2

Application form AWS2 Application form AWS2 For a non-standard (32mm or bigger) connection to an existing water main This form allows you to apply for a non standard (i.e. 32mm or bigger) water service pipe connection. It is

More information

Affinity Water Limited New Supplies

Affinity Water Limited New Supplies 1 of 13 Affinity Water Limited New Supplies Policy and Company Specific Requirements for Water Mains and Service Pipes Constructed by Self-Lay Organisations 2 of 13 CONTENTS 1 Introduction 3 1.1 General

More information

DEVELOPMENT ENGINEERING REVIEW MANUAL (Regional Services)

DEVELOPMENT ENGINEERING REVIEW MANUAL (Regional Services) DEVELOPMENT ENGINEERING REVIEW MANUAL (Regional Services) FEBRUARY, 2005 PLANNING AND TRANSPORTATION SERVICES PLANNING AND PUBLIC WORKS DEPARTMENT TABLE OF CONTENTS Introduction 1 Application Review 1.1

More information

Connection and Developer Services. Code of Practice for Wastewater Infrastructure. (A design and construction guide for customers)

Connection and Developer Services. Code of Practice for Wastewater Infrastructure. (A design and construction guide for customers) Irish Water Connection and Developer Services Code of Practice for Wastewater Infrastructure (A design and construction guide for customers) December 2016 Extract: Section 3.6 Hydraulic Design for Gravity

More information

Company specific addendum

Company specific addendum Self lay policy and Company specific addendum to Code of Practice for the self laying of Water Mains and Services England and Wales 2 nd Edition May 2009 Issue 1.0 - April 2015 life fl ow smoothly helping

More information

your guide to completing an application for a new or replacement water connection from your property to an existing water main

your guide to completing an application for a new or replacement water connection from your property to an existing water main your guide to completing an application for a new or replacement water connection from your property to an existing water main If you wish to apply for a new or replacement water connection you should

More information

TOWAMENCIN TOWNSHIP BUILDING PERMIT PROCEDURES

TOWAMENCIN TOWNSHIP BUILDING PERMIT PROCEDURES TOWAMENCIN TOWNSHIP BUILDING PERMIT PROCEDURES NON-RESIDENTAL BUILDING PERMIT APPLICATION FORM PART I Location of Property Address, Zoning District, Parcel Number and Lot & Block must be provided on all

More information

CHESHIRE EAST COUNCIL. Highways Service. Abridged Conditions, Requirements and Specification of Workmanship and Materials for the Construction of

CHESHIRE EAST COUNCIL. Highways Service. Abridged Conditions, Requirements and Specification of Workmanship and Materials for the Construction of !"#$!%& '( )*& CHESHIRE EAST COUNCIL Highways Service Abridged Conditions, Requirements and Specification of Workmanship and Materials for the Construction of Highways Act 1980: Section 184. C O N T E

More information

your guide to completing an application for a new or replacement water connection from your property to an existing water main

your guide to completing an application for a new or replacement water connection from your property to an existing water main your guide to completing an application for a new or replacement water connection from your property to an existing water main If you wish to apply for a new or replacement water connection you should

More information

Initial Construction Costs For Various Pavement and Drainage Options

Initial Construction Costs For Various Pavement and Drainage Options Interpave Initial Construction Costs For Various Pavement and Drainage Options Final Prepared For Interpave Scott Wilson Ltd Interpave Pavement Design CONTENTS 1. Overview 2. Summary of Pavement Types

More information

COAA EPCM CONTRACT PHILOSOPHY. COAA EPCM Contract Committee

COAA EPCM CONTRACT PHILOSOPHY. COAA EPCM Contract Committee COAA EPCM CONTRACT PHILOSOPHY COAA EPCM Contract Committee 1. Introduction The COAA EPCM Contract Committee, consisting of owner, contractor and affiliate members, has developed a standard form EPCM Contract

More information

3.0 Planning and Submittal Requirements

3.0 Planning and Submittal Requirements October 2003, Revised February 2005 Chapter 3.0, Planning and Submittal Requirements Page 1 3.0 Planning and Submittal Requirements 3.1 Drainage Studies and Drawings The City of Greenwood Village (Village)

More information

GRADING & DRAINAGE PERMIT SOIL EROSION AND SEDIMENTATION CONTROL PERMIT PROGRAM OVERVIEW

GRADING & DRAINAGE PERMIT SOIL EROSION AND SEDIMENTATION CONTROL PERMIT PROGRAM OVERVIEW GRADING & DRAINAGE PERMIT SOIL EROSION AND SEDIMENTATION CONTROL PERMIT PROGRAM OVERVIEW Chapter 8 Building and Building Regulations, Article XIII Grading and Drainage and Article XV Soil Erosion and Sedimentation

More information

Village of Arlington Heights. Sewer Back-up Rebate Program

Village of Arlington Heights. Sewer Back-up Rebate Program Village of Arlington Heights Sewer Back-up Rebate Program (Including Enhanced Program Information) Updated: October 1, 2017 Village of Arlington Heights Building & Life Safety Department 33 S. Arlington

More information

WESTERN WATER DESIGN AND CONSTRUCTION GUIDELINES FOR SUBDIVISIONAL WORKS

WESTERN WATER DESIGN AND CONSTRUCTION GUIDELINES FOR SUBDIVISIONAL WORKS WESTERN WATER DESIGN AND CONSTRUCTION GUIDELINES FOR SUBDIVISIONAL WORKS December 2014 Page 1 Table of contents 1 ROLES AND RESPONSIBILITES... 3 2 GENERAL DESIGN STANDARDS... 8 2.1 Design presentation...

More information

FEES FOR BUILDING REGULATION APPLICATIONS

FEES FOR BUILDING REGULATION APPLICATIONS The Building (Guernsey) FEES FOR BUILDING REGULATION APPLICATIONS The Land Planning and Development (Fees) (Amendment) Regula ons, 2015 Regula ons, 2012 Development & Planning Authority Revised fees for

More information

APPLICATION FOR PUBLIC INFRASTRUCTURE PERMIT

APPLICATION FOR PUBLIC INFRASTRUCTURE PERMIT APPLICATION FOR PUBLIC INFRASTRUCTURE PERMIT Engineering Division 550 Landa Street New Braunfels, Texas 78130 (830) 221-4020 1. Subdivision Plat Name: Location Description/ Nearest Intersection: Acreage:

More information

SPECIFICATION FOR NOISE MITIGATION

SPECIFICATION FOR NOISE MITIGATION SPECIFICATION FOR NOISE MITIGATION 1. SCOPE This specification covers the design, construction, documentation and postconstruction review of state highway road-traffic noise mitigation. This specification

More information

SITE ALTERATION PERMIT INFORMATION PACKAGE FOR LAND OWNERS

SITE ALTERATION PERMIT INFORMATION PACKAGE FOR LAND OWNERS SITE ALTERATION PERMIT INFORMATION PACKAGE FOR LAND OWNERS Revised: June 4, 2014 Requirements for obtaining a site alteration permit vary depending on the type of project being proposed. This information

More information

Dŵr Cymru Welsh Water s Self-lay Policy for Water Mains and Services July 2015

Dŵr Cymru Welsh Water s Self-lay Policy for Water Mains and Services July 2015 Dŵr Cymru Welsh Water s Self-lay Policy for Water Mains and Services July 2015 Introduction This Self-Lay Policy applies when a developer decides to self-lay water mains and services (ie. construct water

More information

Red Fox Run Property Owner s Association, Inc. P.O. Box 194 Tryon, NC 28782

Red Fox Run Property Owner s Association, Inc. P.O. Box 194 Tryon, NC 28782 Red Fox Run Property Owner s Association, Inc. P.O. Box 194 Tryon, NC 28782 Members of the Red Fox Run Property Owner s Association, Inc. Attached are the guidelines of the Architectural Review Committee

More information

CHECKLIST FOR STREETS, INLETS, AND STORM SEWER DESIGN

CHECKLIST FOR STREETS, INLETS, AND STORM SEWER DESIGN CHECKLIST FOR STREETS, INLETS, I. STREET CLASSIFICATION AND DESIGN CRITERIA A. Determine drainage classification for the roadway section using Table 7-1 or Table 7-2. B. Determine the allowable flow depth

More information

Water Connection Application

Water Connection Application Water Connection This application form is to be used for connections to a public water main for the following: Housing Units Site Accommodation Student Accommodation Building Water Guidance section Water

More information

Code of Practice for Exploration Operations

Code of Practice for Exploration Operations Code of Practice for Exploration Operations September 2005 Made under the Environmental Protection and Enhancement Act Published by Alberta Queen s Printer Alberta Queen s Printer Suite 700, Park Plaza

More information

SOLID FUEL HEATER APPLICATION FOR PROJECT INFORMATION MEMORANDUM AND /OR BUILDING CONSENT Section 33 or 45, Building Act 2004

SOLID FUEL HEATER APPLICATION FOR PROJECT INFORMATION MEMORANDUM AND /OR BUILDING CONSENT Section 33 or 45, Building Act 2004 Property File ID #: Civic Centre 1061 Haupapa Street Private Bag 3029 Rotorua Mail Centre Rotorua 3046 P: 07 348 4199 F: 07 346 3143 E: info@rotorualc.nz W: www.rotorualakescouncil.nz Form 2 SOLID FUEL

More information

Index. Composition and Order of Plan Set. Utility Plan... 5

Index. Composition and Order of Plan Set. Utility Plan... 5 City of Des Plaines Public Works and Engineering Department Revised-October 5, 2012 Index Composition and Order of Plan Set Title Page Number Cover Sheet... 1 Requirements for Site Development... 2 Grading

More information

Section 33 or 45. Building Act Please enter National Multiple-Use Approval number below:

Section 33 or 45. Building Act Please enter National Multiple-Use Approval number below: APPLICATION FOR BUILDING CONSENT (Form 2) Section 33 or 45. Building Act 2004. COUNCIL USE ONLY BC Number Receipt Number Amount Paid 1. What are you applying for? Tick all applicable ¹ For PIM only applications

More information

INSPECTION AND ACCEPTANCE FOR MAINTENANCE

INSPECTION AND ACCEPTANCE FOR MAINTENANCE Inspection and Acceptance For Maintenance Page 1 (Last revised 6/29/10) INSPECTION AND ACCEPTANCE FOR MAINTENANCE SELECTED LINKS TO SECTIONS WITHIN THIS SPECIFICATION Acceptance Sewer As Built Drwg Example

More information

Polysewer Gravity Sewer System SPECIFICATION

Polysewer Gravity Sewer System SPECIFICATION Polysewer Gravity Sewer System SPECIFICATION July 2014 SCOPE OF WORKS To meet the specific performance criteria detailed within this specification and accompanying drawings. The completed drainage systems

More information

Policies and Procedures

Policies and Procedures Policies and Procedures Provided by PROGuard The following are policies and procedures which need to be enforced to ensure PCI DSS compliance. In order to answer yes to the questions and pass the SAQ,

More information

Developers Manual. Version 1.23

Developers Manual. Version 1.23 Version 1.23 REVISIONS The following clauses in this manual were revised on the dates shown. Revision Number Issue Date Reason for Change 1.0 4 August 1999 Initial Issue 1.1 6 April 2000 Amendments to

More information

New Water Connection Application (up to 32mm) Article 79 - Water and Sewerage Services (Northern Ireland) Order 2006

New Water Connection Application (up to 32mm) Article 79 - Water and Sewerage Services (Northern Ireland) Order 2006 New Water Connection Application (up to 32mm) Article 79 - Water and Sewerage Services (Northern Ireland) Order 2006 Please note - this form can be used to apply for new or replacement water connections

More information

S.O.P. No. HMD

S.O.P. No. HMD Page: 1 of 9 PURPOSE: To establish (SOP) for submission requirements, review process and approval of applications for Non-vehicular Access Permits for the purpose of connection or discharge to any MassDOT

More information

PART 2 : CONTACT NAMES (PLEASE SUPPLY WHERE APPLICABLE) Managing Director Title: Technical Job title: Sales Job title: Accounts (for invoices etc.) Jo

PART 2 : CONTACT NAMES (PLEASE SUPPLY WHERE APPLICABLE) Managing Director Title: Technical Job title: Sales Job title: Accounts (for invoices etc.) Jo INDUSTRIAL ASSOCIATE SUPPORTER APPLICATION FORM Play a key role in your industry Industrial Associate Supporters play a key role in raising the profile of the industry. By working with the CIPHE you will

More information

This guide only applies for sewer assets up to and including 225mm diameter.

This guide only applies for sewer assets up to and including 225mm diameter. INTRODUCTION This guide only applies for sewer assets up to and including 225mm diameter. These guidelines (subject to change) provide an outline of the requirements which need to be considered when planning

More information

SECTION 6 STORMWATER AND LAND DRAINAGE

SECTION 6 STORMWATER AND LAND DRAINAGE SECTION 6 STORMWATER AND LAND DRAINAGE Final Version, Approved September 2003 Section 6 and Land Drainage Contents 6.1 PERFORMANCE STANDARDS... 2 6.1.1 General... 2 6.2 MEANS OF COMPLIANCE... 3 6.2.1 General...

More information

DIEMERSFONTEIN WINE & COUNTRY ESTATE BUILDING CONTRACTORS CODE OF CONDUCT

DIEMERSFONTEIN WINE & COUNTRY ESTATE BUILDING CONTRACTORS CODE OF CONDUCT DIEMERSFONTEIN WINE & COUNTRY ESTATE BUILDING CONTRACTORS CODE OF CONDUCT 1. CODE OF CONDUCT AGREEMENT The building contractor is a builder/contractor ( the contractor ) appointed by the owner ( the employer

More information

Electricity Supply Agreement

Electricity Supply Agreement Electricity Supply Agreement 1. General 1.1 Mazoon Electricity Company SAOC (the Supplier) shall on or from the Start Date, subject to the satisfactory completion of a Supply Application Form, provide

More information

Last Updated March 15, 2016

Last Updated March 15, 2016 CASS COUNTY, MISSOURI BUILDING CODES, ENVIRONMENTAL HEALTH AND ZONING DEPARTMENT 30508 S. West Outer Road, Harrisonville, MO 64701 P- (816) 380-8134 F- (816) 380-8130 Last Updated March 15, 2016 Information

More information

National TFS Office, Dublin City Council [NTFSO] Guidance for Completing Notification Document (Annex 1A) & Movement Document (Annex 1B)

National TFS Office, Dublin City Council [NTFSO] Guidance for Completing Notification Document (Annex 1A) & Movement Document (Annex 1B) National TFS Office, Dublin City Council [NTFSO] Guidance for Completing Notification Document (Annex 1A) & Movement Document (Annex 1B) Introduction A planned shipment subject to the procedure of prior

More information

Ordinance No Lot Surface Drainage

Ordinance No Lot Surface Drainage Ordinance No. 35-2008 - Lot Surface Drainage The Township has adopted a new Lot Surface Drainage Ordinance which amends Chapter 170, Article IX, Subdivision and Site Plan Review by adding a new Section

More information

Price Conditions for Transferred Customers for the Supply of Water and Sewerage Services

Price Conditions for Transferred Customers for the Supply of Water and Sewerage Services 1. NWG Business Limited Price Conditions for for the Supply of Water and Sewerage Services These Price Conditions are an annex to the Scheme of Terms and Conditions for Transferred Customers and should

More information

Permit for Construction of an Extension to a JEA Drinking Water Distribution System and/or JEA Wastewater Collection/Transmission System

Permit for Construction of an Extension to a JEA Drinking Water Distribution System and/or JEA Wastewater Collection/Transmission System Permit for Construction of an Extension to a JEA Drinking Water Distribution System and/or JEA Wastewater Collection/Transmission System INSTRUCTIONS: This form shall be completed and submitted (in duplicate)

More information

CITY OF BENICIA IMPROVEMENT PLAN REVIEW CHECKLIST

CITY OF BENICIA IMPROVEMENT PLAN REVIEW CHECKLIST CITY OF BENICIA DEPARTMENT OF PUBLIC WORKS ENGINEERING DIVISION 250 EAST L STREET, BENICIA, CA 94510 Phone: (707) 746-4240 CITY OF BENICIA IMPROVEMENT PLAN REVIEW CHECKLIST Tract Map # This checklist is

More information

National Transmission System Gas Connection Application Guide

National Transmission System Gas Connection Application Guide National Transmission System Gas Connection Application Guide Gas Customer Team 1 Welcome Welcome to this guide on how to make a Gas NTS Connection Application. We hope that the information provided will

More information

Residential Sewer Backup Prevention Program

Residential Sewer Backup Prevention Program City of Wheaton Residential Sewer Backup Prevention Program Please Note: The City reserves the right to modify the policies, procedures and rules of this program or discontinue the program in its entirety

More information

CUSTOMER CHARTER A SUMMARY OF YOUR RIGHTS AND RESPONSIBILITIES

CUSTOMER CHARTER A SUMMARY OF YOUR RIGHTS AND RESPONSIBILITIES CUSTOMER CHARTER A SUMMARY OF YOUR RIGHTS AND RESPONSIBILITIES At Queensland Urban Utilities, we are focused on providing accountable, efficient and innovative customer service. As our customers, you

More information

HAUC England Advice Note No. 2014/02. Code of Practice for Inspections: Defects Not Causing Danger Inspections ENGLAND

HAUC England Advice Note No. 2014/02. Code of Practice for Inspections: Defects Not Causing Danger Inspections ENGLAND HAUC England Advice Note No. 2014/02 Code of Practice for Inspections: Defects Not Causing Danger Inspections ENGLAND Version: VI Control Document No.: 1 Document Owner: Roger Culpin and Mark Ostheimer

More information

STORMWATER AND EROSION CONTROL PERMIT

STORMWATER AND EROSION CONTROL PERMIT STORMWATER MANAGEMENT AND EROSION CONTROL PERMIT INSTRUCTIONS AND INFORMATION Any project that involves the disturbance of ANY quantity of land requires the applicant to receive approval for the project

More information

DETAILED TERMS OF REFERENCE. 1.0 Terms Of Reference: I.1 The scope of services of a consultant shall include the following categories:

DETAILED TERMS OF REFERENCE. 1.0 Terms Of Reference: I.1 The scope of services of a consultant shall include the following categories: DETAILED TERMS OF REFERENCE 1.0 Terms Of Reference: I.1 The scope of services of a consultant shall include the following categories: 1. To study existing SWM practice and Drainage system in the city.

More information

ASBESTOS DEMOLITION/RENOVATION NOTIFICATION FORM GENERAL INFORMATION

ASBESTOS DEMOLITION/RENOVATION NOTIFICATION FORM GENERAL INFORMATION ASBESTOS DEMOLITION/RENOVATION NOTIFICATION FORM GENERAL INFORMATION The asbestos NESHAP, 40 CFR, Part 61, Subpart M, requires written notification of demolition or renovation operations under Section

More information

You are also similarly responsible for any part crossing any neighbouring land, including any length of private service pipe in the public highway.

You are also similarly responsible for any part crossing any neighbouring land, including any length of private service pipe in the public highway. Shared supply or lead water pipe replacement connections guidance notes Up to 25mm diameter supplies Introduction Our aim is to deliver an excellent standard of service. In order for us to do this and

More information

COMMISSIONERS OF PUBLIC WORKS of the CITY OF CHARLESTON, SOUTH CAROLINA DEVELOPMENT POLICIES

COMMISSIONERS OF PUBLIC WORKS of the CITY OF CHARLESTON, SOUTH CAROLINA DEVELOPMENT POLICIES COMMISSIONERS OF PUBLIC WORKS of the CITY OF CHARLESTON, SOUTH CAROLINA DEVELOPMENT POLICIES TABLE OF CONTENTS DEFINITIONS WATER POLICIES Water System Extensions.... W88001 Water System Activation / Service

More information

MINIMUM STANDARDS AND CONSTRUCTION SPECIFICATIONS FOR WATER AND WASTEWATER SYSTEMS PREFACE

MINIMUM STANDARDS AND CONSTRUCTION SPECIFICATIONS FOR WATER AND WASTEWATER SYSTEMS PREFACE MINIMUM STANDARDS AND CONSTRUCTION SPECIFICATIONS FOR WATER AND WASTEWATER SYSTEMS PREFACE The Citrus County Water Resources Department, Utilities Division is committed to providing cost effective, quality

More information

The Environmental Management and Protection (Saskatchewan Environmental Code Adoption) Regulations

The Environmental Management and Protection (Saskatchewan Environmental Code Adoption) Regulations ENVIRONMENTAL MANAGEMENT 1 ENVIRONMENTAL CODE ADOPTION) E-10.22 REG 2 The Environmental Management and Protection (Saskatchewan Environmental Code Adoption) Regulations being Chapter E-10.22 Reg 2 (effective

More information

VIENNA JUNE 2017

VIENNA JUNE 2017 EXHIBITION STANDS SPACE ONLY STANDS The space contracted refers solely to the floor and its perimeter. Therefore, exhibitors must decorate this surface area in accordance with their needs. The Organiser

More information

development impact assessment (DIA)

development impact assessment (DIA) application for a development impact assessment (DIA) Form E Important Please te there may have been significant changes to the requirements/process since you last used this form. We only accept electronic

More information

CITY UTILITIES DESIGN STANDARDS MANUAL

CITY UTILITIES DESIGN STANDARDS MANUAL CITY UTILITIES DESIGN STANDARDS MANUAL () September 2017 Page Chapter 1 Acronyms and Definitions 1.01 Purpose 1 1.02 Acronyms 1 1.03 Definitions 3 Chapter 2 Introduction 2.01 Purpose 1 2.02 Applicability

More information

Asbestos Management Plan. Program originated: 02/2000 Last updated: 6/2015. Wendel Reece University Safety Manager

Asbestos Management Plan. Program originated: 02/2000 Last updated: 6/2015. Wendel Reece University Safety Manager Asbestos Management Plan Program originated: 02/2000 Last updated: 6/2015 Wendel Reece University Safety Manager TABLE OF CONTENTS I. Introduction II. Purpose III. Operations and Maintenance Asbestos Related

More information

Northumbrian Water Limited 9 March 2011

Northumbrian Water Limited 9 March 2011 Northumbrian Water Limited 9 March 2011 Flooding - The role of water companies in addressing flooding and SuDs. Les Hall New Development Manager Introduction Northumbrian Water and our sewerage role. Our

More information

TORONTO MUNICIPAL CODE CHAPTER 813, TREES. Chapter 813 TREES. ARTICLE I Inspection; Removal of Infested Trees

TORONTO MUNICIPAL CODE CHAPTER 813, TREES. Chapter 813 TREES. ARTICLE I Inspection; Removal of Infested Trees Chapter 813 TREES ARTICLE I Inspection; Removal of Infested Trees 813-1. Inspection for presence of Asian Long-Horned Beetles and other pests; removal of infested trees. 813-2. Right to enter private property.

More information

UCTURE RESOURCE CENTER

UCTURE RESOURCE CENTER This document has been prepared for the purposes of the PPP IN INFRASTRUCTURE RESOURCE CENTER FOR CONTRACTS, LAWS AND REGULATIONS (PPPIRC) website. It is a sample document FOR REFERENCE PURPOSES ONLY and

More information

Landscaping and Fencing

Landscaping and Fencing Landscaping and Fencing Fences, driveways, paving, retaining walls, landscaping & other garden features To be read in conjunction with General Requirements: A guide to building on properties containing

More information

Table of Contents INTRODUCTION

Table of Contents INTRODUCTION i Blank page ii Table of Contents INTRODUCTION PART A WHOLESALE CHARGING METHODOLOGY... 6 1 SCOPE OF THIS CHARGES SCHEME... 6 2 DEFINITIONS... 8 3 INFORMATION ABOUT NWL... 11 3.2 Contact Details... 11

More information

Drainage By-law. WM-4 Consolidated as of April 18, 2011

Drainage By-law. WM-4 Consolidated as of April 18, 2011 Drainage By-law WM-4 Consolidated as of April 18, 2011 As Amended by By-law No. Date Passed at Council WM-4 September 20, 1993 WM-4-95001 September 18, 1995 WM-4-96002 August 6, 1996 WM-4-97003 May 5,

More information

RESIDENTIAL FIRE SERVICE METERS Addendum #1

RESIDENTIAL FIRE SERVICE METERS Addendum #1 109 WATER METERS (Addendum #1) 109.1 GENERAL All meters to be used for billing purposes shall be provided by the Water Utility. The Water Utility reserves the right to read, inspect, test or replace the

More information

CABONNE COUNCIL DEVELOPMENT CONTROL PLAN NO. 15 RELOCATABLE AND TRANSPORTABLE HOMES

CABONNE COUNCIL DEVELOPMENT CONTROL PLAN NO. 15 RELOCATABLE AND TRANSPORTABLE HOMES CABONNE COUNCIL DEVELOPMENT CONTROL PLAN NO. 15 RELOCATABLE AND TRANSPORTABLE HOMES As approved by Council at the meeting of 20 June 2005 Came into effect on 14 July 2005 I, G. L. P. Fleming, General Manager,

More information

PUMP STATION CHECK LIST

PUMP STATION CHECK LIST PUMP STATION CHECK LIST I. SITE LOCATION D. E. Location of pump station site has to be reviewed and approved by Planning Department and Department of Public Utilities. (II-V-F-1-J-i) The pump station has

More information

Forest (Conservation) Rules, 1981

Forest (Conservation) Rules, 1981 Forest (Conservation) Rules, 1981 (as amended up to May 1992) G.S.R. 719... in exercise of the powers conferred by sub-section (i) of section 4 of the Forest (Conservation) Act, 1980 (69 of 1980), the

More information

Part 148. CAA Consolidation. 10 March Aircraft Manufacturing Organisations - Certification

Part 148. CAA Consolidation. 10 March Aircraft Manufacturing Organisations - Certification Part 148 CAA Consolidation 10 March 2017 Aircraft Manufacturing Organisations - Certification Published by the Civil Aviation Authority of New Zealand DESCRIPTION Part 148 prescribes rules governing the

More information

Postcode: Tel: Fax: 4. Proposed work Description (see note 4):

Postcode: Tel: Fax:   4. Proposed work Description (see note 4): BUILDING NOTICE The Building Act 1984 The Building Regulations 2010 Building Control Place Directorate Stopford House Piccadilly SK1 3XE This form is to be filled in by the person (or his/her agent) who

More information

Guidance for environmental permit applications: Radioactive substances activity Part RSR-A About you and your premises

Guidance for environmental permit applications: Radioactive substances activity Part RSR-A About you and your premises Guidance for environmental permit applications: Radioactive substances activity Part RSR-A About you and your premises Please read these guidance notes carefully before you fill in the forms. All relevant

More information

LANDFORM SuDS not duds Local Authority guidance on SuDS 03/11/2010. Ciria LANDFORM event: SuDS not duds Local Authority Guidance: 3 November 2010

LANDFORM SuDS not duds Local Authority guidance on SuDS 03/11/2010. Ciria LANDFORM event: SuDS not duds Local Authority Guidance: 3 November 2010 Ciria LANDFORM event: SuDS not duds Local Authority Guidance: 3 November 2010 The Regulatory Context for Sustainable Drainage Systems (SuDS): Flood and Water Management Act 2010 Vicky Dawe Defra, Head

More information

I. RELEASE FROM PLANNING PRIOR TO SUBMITTAL TO ENGINEERING DEPARTMENT

I. RELEASE FROM PLANNING PRIOR TO SUBMITTAL TO ENGINEERING DEPARTMENT Revised August 2005 I. RELEASE FROM PLANNING PRIOR TO SUBMITTAL TO ENGINEERING DEPARTMENT Before the applicant submits improvement plans and reports for Engineering plan checking, the applicant shall contact

More information

DRIFFIELD GOLF CLUB - ADMINISTRATIVE ASSISTANT

DRIFFIELD GOLF CLUB - ADMINISTRATIVE ASSISTANT DRIFFIELD GOLF CLUB - ADMINISTRATIVE ASSISTANT Driffield Golf Club (DGC) requires an Administrative Assistant to support the Club and its Management Committee. The post will be part time, working on Tuesday,

More information

Temporary Watercourse Crossing: Culverts

Temporary Watercourse Crossing: Culverts Temporary Watercourse Crossing: Culverts DRAINAGE CONTROL TECHNIQUE Low Gradient Velocity Control Short Term Steep Gradient Channel Lining Medium-Long Term Outlet Control Soil Treatment Permanent Symbol

More information

Form 1: Application for resource consent

Form 1: Application for resource consent Form 1: Application for resource consent All sections must be completed in full and accompanied by the initial fixed application fee (see section 11) and the relevant activity form (see section 7). Failure

More information

UNIFORM DESIGN AND CONSTRUCTION STANDARDS FOR EXTENDING WATER DISTRIBUTION SYSTEMS SECTION 2 DESIGN STANDARDS

UNIFORM DESIGN AND CONSTRUCTION STANDARDS FOR EXTENDING WATER DISTRIBUTION SYSTEMS SECTION 2 DESIGN STANDARDS UNIFORM DESIGN AND CONSTRUCTION STANDARDS FOR EXTENDING WATER DISTRIBUTION SYSTEMS SECTION 2 DESIGN STANDARDS DESIGN STANDARDS SECTION 2 INDEX ITEM DESCRIPTION 2.00 GENERAL STATEMENT 2.01 WATER DISTRIBUTION

More information

TORONTO MUNICIPAL CODE CHAPTER 851, WATER SUPPLY. Chapter 851 WATER SUPPLY

TORONTO MUNICIPAL CODE CHAPTER 851, WATER SUPPLY. Chapter 851 WATER SUPPLY Chapter 851 WATER SUPPLY 851-1. Definitions. 851-2. Administration. 851-3. Use and receipt of water. 851-4. Water service connections. 851-5. Metering of water. 851-6. Water meter inspection. 851-7. Maintenance.

More information

Copyright Notice: Publishers: ISBN: Printed: 30 December BSBFIA304A: Maintain a general ledger

Copyright Notice: Publishers: ISBN: Printed: 30 December BSBFIA304A: Maintain a general ledger A Step by Step Approach to Maintaining a General Ledger using MYOB Accounting v18 Copyright Notice: Copyright 2008 Marian Brown. All rights reserved. No part of this material may be reproduced or copied

More information

BYRON TOWNSHIP BUILDING PERMIT APPLICATION 8085 Byron Center Ave SW., Byron Center, MI /Fax

BYRON TOWNSHIP BUILDING PERMIT APPLICATION 8085 Byron Center Ave SW., Byron Center, MI /Fax BYRON TOWNSHIP BUILDING PERMIT APPLICATION 8085 Byron Center Ave SW., Byron Center, MI 49315 616-878-9155/Fax 616-878-0699 Applicant to complete all items in Section I, II, III, IV, V Note: Separate applications

More information

[A company or firm must apply through an individual in accordance with its Articles of Association or partnership agreement]

[A company or firm must apply through an individual in accordance with its Articles of Association or partnership agreement] Form: EMA/WDR 2 APPLICATION FOR WASTE DISPOSAL PERMIT (Reg. 46) Legal background: 1 A commercial or industrial facility must not dispose of any solid waste, discharge liquid waste, dispose or discharge

More information

GUIDE TO THE PREPARATION OF A WORKING PLAN SCRAPYARD / ELV FACILITY

GUIDE TO THE PREPARATION OF A WORKING PLAN SCRAPYARD / ELV FACILITY GUIDE TO THE PREPARATION OF A WORKING PLAN SCRAPYARD / ELV FACILITY A working plan is an essential document and consists of a written statement accompanied by plans, drawings and specifications detailing

More information

Obtaining water supplies for new developments

Obtaining water supplies for new developments Obtaining water supplies for new developments Guidance notes for developers Issue 1.0 - April 2015 life fow smoothly helping helpin life f ow smoothly hel ping helping life fow smoothly life fow smoothly

More information

SAFE WORK METHOD STATEMENT

SAFE WORK METHOD STATEMENT SWMS 002 Erect / Dismantle Single Bay Towers and/or Multiple Bay Towers Page of 9 ABN: 40 088 478 399 This SWMS has been prepared and authorised by OLDFIELDS ACCESS PTY LTD ACN: 088 478 399 Date: Issue

More information