1 LANDFILL SITE [CLOSED 00] PLAN TITLE LIST OF DRAWINGS EXISTING PROCESS DIAGRAM PROPOSED PROCESS DIAGRAM EXISTING EQUIPMENT LAYOUT PLAN PROPOSED EQUIPMENT LAYOUT PLAN ELEVATION D AND DETAILS
2 TREATMENT ISOLATION VALVE FLOAT VALVE MANIFOLD TO PRESSURE REDUCING VALVE 5Ø PVC 8Ø PVC FILTERED WATER. ALL DIMENSIONS ARE SHOWN IN MILLIMETRES BASKET STRAINER. ITEMS TO BE REMOVED SHALL BE TURNED OVER TO THE. PRESSURE GAUGE 5Ø 5Ø UNION 8Ø PVC INCREASER/DECREASER WATER SUPPLY DRAIN LINE FEATURE FILTER 8Ø PVC TO FOUNTAIN FILTER ITEMS TO BE REMOVED PVC 8Ø PVC Ø HOSE Ø HOSE PRIMING CONNECTIONS 8Ø PVC BACKWASH DISCHARGE Ø MAKE-UP WATER BACK FLOW PREVENTER FLOAT VALVE - COMPARTMENT CONCRETE TANK 000 GALLON WATERMAIN SANITARY SEWER 0// ISSUED FOR TENDER GAP 0/0/ ISSUED FOR APPROVAL GAP ITEM No. ITEM DESCRIPTION REMARKS - COMPARTMENT CONCRETE TANK, 000 GALLON FILTER - JACUZZI MODEL -MAG-U-S, HP 5 55 FT TDH PAC-FAB TAGELUS SAND FILTER MODEL TA0 CHLORINE DISPENSER PENTAIR RAINBOW LIFEGARD MODEL HC-0 5 CHLORINE ANALYZER FEATURE - JACUZZI MODEL 5VMB-T5.5HP 00 0FT TDH PORTABLE TESTER (TAYLOR POOL WATER TEST KIT), APOLLO MODEL RPA, mmø 8 MANIFOLD TO N/A MARCH 0-0- March, dwg
3 / / / / GENERATER TREATMENT 00Ø ST. STL 00Ø ST. STL 5Ø PH ORP 5Ø PVC MANIFOLD TO / / / / FLANGED CONNECTION OR TRANSITION COUPLING (TYP. x) / / STARTER (EXISTING) DRAIN DRAIN 5Ø 5Ø Ø PRIMING LINE / S Ø / / S 5Ø PVC FILTERED WATER BACK FLOW PREVENTER 5Ø 5Ø PVC FM 5Ø CLEAR PVC SIGHT TUBE 500mm LONG. ALL DIMENSIONS ARE SHOWN IN MILLIMETRES. MAIN PROCESS PIPING TO BE SCHEDULE 80 PVC. PLUMBING LINES TO BE TYPE L COPPER UNLESS. PROVIDE PIPE BANDING TAPE WITH FLOW ITEM No. ITEM DESCRIPTION REMARKS - COMPARTMENT CONCRETE TANK, 000 GALLON FILTER REMOVED - COMPARTMENT CONCRETE TANK 000 GALLON WATERMAIN SANITARY SEWER CHLORINE DISPENSER ISOLATION VALVE ARV AIR RELEASE VALVE WATER SUPPLY 0// ISSUED FOR TENDER GAP 0/0/ ISSUED FOR APPROVAL GAP, APOLLO MODEL RPA, mmø S ELECTRIC SOLENOID VALVE FM CHEMICAL FEED LINE MANIFOLD TO FLOAT VALVE BASKET STRAINER DRAIN LINE PRV PRESSURE RELIEF VALVE PRESSURE GAUGE / COMMUNICATION LINE PRESSURE REDUCING VALVE UNION NORMALLY CLOSED INCREASER/DECREASER SAMPLE VALVE mmø HOSE BIB CONNECTION MARCH 0-0- March, dwg
4 OUTSIDE B OUTSIDE WASH DIESEL A A TREATMENT FD FD. ALL DIMENSIONS ARE SHOWN IN MILLIMETRES WATER HEATER MOUNTED ABOVE DOOR SEE NOTE & RELOCATE CORK BOARD RELOCATE SHELF. MAIN PROCESS PIPING TO BE SCHEDULE 80 PVC. PLUMBING LINES TO BE TYPE L COPPER UNLESS. PROVIDE PIPE BANDING TAPE WITH FLOW B ELECTRICAL EMERGENCY LIGHTING CABINETS ELECTRICAL BOXES. REMOVE FILTER, CABLES, CONDUIT, STARTER & ELECTRICAL BOXES. TERMINATE PER ELECTRICAL CODE.. ITEMS TO BE REMOVED SHALL BE TURNED OVER TO THE. 8. EX. CORK BOARD AND SHELF TO BE RELOCATED PER INSTRUCTIONS. SCALE: :5 GYM SCALE: :0 ITEM No. ITEM DESCRIPTION REMARKS - COMPARTMENT CONCRETE TANK, 000 GALLON FILTER - JACUZZI MODEL -MAG-U-S, HP 5 55 FT TDH EXISTING -TO REMAIN EX. INSULATED ROOF DRAIN OUTSIDE TO WALL HYDRANT INSIDE BFP HEATER EX. INSULATED ROOF DRAIN 00 0// ISSUED FOR TENDER GAP 0/0/ ISSUED FOR APPROVAL GAP PAC-FAB TAGIELLIS SAND FILTER MODEL TA0 CHLORINE DISPENSER PENTAIR RAINBOW LIFEGARD MODEL HC-0 5 CHLORINE ANALYZER PORTABLE TESTER USED FEATURE - JACUZZI MODEL 5VMB-T5.5HP 00 0FT TDH EXISTING - TO BE REPLACED 8 N/A 0 MANIFOLD TO SCALE: :0 SCALE: :0 SCALE: :0 MARCH 0-0- March, dwg
5 OUTSIDE C WASH TREATMENT DIESEL OUTSIDE D FROM UV. ALL DIMENSIONS ARE SHOWN IN MILLIMETRES ELECTRICAL PROVIDE UNI-STRUT SUPPORTS UNDER FRONT OF UV CONTROL PANEL & UNDER UV REACTOR ANCHORED TO THE FLOOR D FEATURE H-O-A SWITCH E-STOP MEDIA FILTERS (x) BACKWASH WATER FILTERED WATER TO UV. MAIN PROCESS PIPING TO BE SCHEDULE 80 PVC. PLUMBING LINES TO BE TYPE L COPPER UNLESS. PROVIDE PIPE BANDING TAPE WITH FLOW. UV SYSTEM HAS 00mm ( INCH) FLANGED CONNECTIONS.. ALL MAIN LINE ISOLATION VALVES 00mmØ OR LARGER TO BE FLANGED PVC BUTTERFLY VALVES WITH LEVER OPERATORS. 8. ALL MAIN LINE ISOLATION VALVES 5mmØ OR SMALLER TO BE TRUE UNION PVC BALL VALVES. C ELECTRICAL BOXES (REMOVE ELECTRICAL BOXES FOR FILTER ). CONTRACTOR SHALL ARRANGE AND PAY FOR ESA INSPECTION AND PROVIDE ESA CLEARANCE CERTIFICATION TO PRIOR TO SUBSTANTIAL PERFORMANCE. GYM SCALE: :0 SCALE: :5 ITEM No. ITEM DESCRIPTION REMARKS - COMPARTMENT CONCRETE TANK, 000 GALLON FILTER CHLORINE DISPENSER MANIFOLD TO REMOVED // ISSUED FOR TENDER GAP 0/0/ ISSUED FOR APPROVAL GAP CLEARANCE FOR UV MAINTENANCE SCALE: :0 0 SCALE: :0 MARCH 0-0- March, dwg
6 -00Ø 5S STAINLESS STEEL PIPES FLANGED TRANSITION CONNECTION (TYP. x) - PIPES NEW FILTER METER UV BYPASS VALVE EX. mmø MAKE-UP WATER LINE TO TANK OWSJ TO EX. MANIFOLD TREATMENT FM 5xØ FROM NEW FILTERS NEW FILTER (TYP. x) SEE DETAIL FOR PIPE PENETRATION THROUGH WALL (TYP.) EX. 0 mm THICK CONCRETE PAD (TYP.) EX. EXHAUST FAN EX. INTAKE DAMPER EX. DIESEL CLEARANCE BETWEEN WALL AND TO BE 800mm H x 00mm W NEW UV CONTROL PANEL NEW UV REACTOR PROVIDE UNI-STRUT SUPPORTS UNDER FRONT OF UV CONTROL PANEL & UNDER UV REACTOR ANCHORED TO THE FLOOR CONCRETE FLOOR EX. CONCRETE BLOCK WALL (TYP.) VENT HOLE AT TOP OF PIPE CUT BOTTOM END OF PIPE AT 5 ANGLE AND REMOVE SHARP EDGES TRANSDUCER TO BE ACCESSIBLE FROM ACCESS HATCH 00Ø CONTINUOUS SDR PVC PIPE C/W BLIND FLANGE TO SUIT INSTALLATION OF ULTRASONIC LEVEL TRANSDUCER 50 x 0 SS PIPE SUPPORTS FASTENED TO WALL WITH Ø SS CHEMICALLY BONDED MAX SPACING OF 000mm NOTES:. LOCATE PIPE AND TRANSDUCER NEAR HATCH FOR ACCESSIBLITY. PIPE SHALL HAVE NO HORIZONTAL SEAMS. ALL DIMENSIONS ARE SHOWN IN MILLIMETRES. MAIN PROCESS PIPING TO BE SCHEDULE 80 PVC. PLUMBING LINES TO BE TYPE L COPPER UNLESS. PROVIDE PIPE BANDING TAPE WITH FLOW. UV SYSTEM HAS 00mm ( INCH) FLANGED CONNECTIONS.. ALL MAIN LINE ISOLATION VALVES 00mmØ OR LARGER TO BE FLANGED PVC BUTTERFLY VALVES WITH LEVER OPERATORS. 8. ALL MAIN LINE ISOLATION VALVES 5mmØ OR SMALLER TO BE TRUE UNION PVC BALL VALVES.. CONTRACTOR SHALL ARRANGE AND PAY FOR ESA INSPECTION AND PROVIDE ESA CLEARANCE CERTIFICATION TO PRIOR TO SUBSTANTIAL PERFORMANCE SCALE: :0 5Ø AND 00Ø PIPE 0Ø PLASTIC COATED U-BOLT (EQUAL TO INTERNATIONAL FIG C) 50 x 50 x x 00 LONG ANGLE (TYP. x) Ø WASHER (TYP. x) Ø NUT (TYP. x) CONCRETE ANCHOR BOLT (TYP.) 50 x THICK PLATE WELDED TO ANGLES 5mm LONG SLOT FOR U-BOLTS C 00 L 00 0 x 0 x. SS HSS Ø SS ANCHOR BOLTS SS STRAP mm THICK x 50mm WIDE TO MATCH PIPE OD PIPE RUN 0 x 0 x ANGLE Ø SS HILTI HIT HY50 ANCHORS WITH SS RODS (TYP. x) SS BASE PLATE 50 x 50 x WELDED TO SS HSS TREATMENT/ INVERT EX. CONCRETE WALL STEEL PIPE SLEEVE w/ PUDDLE FLANGE NON-SHRINK GROUT FIRE STOP SEAL PIPE TOP CORD OF JOIST PIPE BOTTOM CORD OF JOIST HEAVY DUTY C-CLAMP (EQUAL TO ANVIL FIG. ) 5 8 " (mmø) THREADED ROD INSULATED CLEVIS HANGER (EQUAL TO ANVIL FIG. 0 ISS) 0// ISSUED FOR TENDER GAP 0/0/ ISSUED FOR APPROVAL GAP (FOR HORIZONTAL PIPE RUNS) (FOR VERTICAL PIPE RUNS) MAX SPACING.5m MAX SPACING.5m MAX SPACING.5m 0 SCALE: :0 MARCH March, dwg
6" RETURN FROM PUMP RESERVOIR LABELED "ph" 6" RECIRCULATION SUCTION (TYP OF 2) 6" BUTTERFLY VALVE (TYP OF 2) 2" RECIRC PUMP TO FILTER RECIRCULATION PUMP 2" PUMP TO WASTE CHLORINE FEEDER ELECTRICAL PANEL
More informationPLUMBING BUILDING SCOPE OF WORK
PLUMBING BUILDING SCOPE OF WORK 1. The Contractor shall furnish all supervision, materials, labor, equipment, tools, supplies, incidental items, including construction cleanup, etc for accomplishing the
More informationISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION
ISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION FIBERGLASS PACKAGE LS SITE PLAN PAGE No. 111 NUMBER: FG-LS-SITE-PLN FIBERGLASS PACKAGE LS PIPING PLAN PAGE No. 112 NUMBER: FG-LS-PIPE-PLN
More informationSECTION PLUMBING PIPING
SECTION 22 1000 PLUMBING PIPING PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Perform Work in accordance with authority having jurisdiction standards. Utilize products as indicated in drawings and as allowed
More informationSUPPORT AND ANCHORS SECTION 15090
SUPPORT AND ANCHORS SECTION 15090 PART 1 GENERAL 1.1 DESCRIPTION OF WORK A. Work included in this Section: Materials, equipment, fabrication, installation and tests in conformity with applicable codes
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping
SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of
More informationEngineering Design Center. Standard Drawings. 1st Edition -January 2016
Engineering Design Center Standard Drawings 1st Edition -January 2016 Golden State Water Company Standard Drawings 1/11/2016 Table of Contents PART A STANDARD DRAWINGS Section I Pipeline Construction P-1
More informationSECTION BASIC FIRE SUPPRESSION MATERIALS AND METHODS. A. Section includes pipe, fittings, valves, and connections for sprinkler systems.
SECTION 210500 - BASIC FIRE SUPPRESSION MATERIALS AND METHODS PART 1 GENERAL 1.1 SUMMARY A. Section includes pipe, fittings, valves, and connections for sprinkler systems. B. Related Sections: 1. Section
More informationADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities
ADDENDUM NO. TO Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities Date of Addendum: December, 00 Hethcoat & Davis, Inc. 78 Franklin Road,
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING
SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationSeptember 6, 2016 Page 1 of 5
September 6, 2016 Page 1 of 5 1. SECTION 16100 Drawing E4.3, Note #39: Reference to the radio fire alarm panel and the fire station alerting master panel does not relate to the building fire alarm system.
More informationBid Opportunity PLUMBING SYSTEMS Section Installation of Boiler Heating Systems Page 1 of 7 Centennial Pool, 90 Sinclair
Installation of Boiler Heating Systems Page 1 of 7 SECTION PAGE PART 1 GENERAL 2 1.1 General 2 1.2 Reference 2 1.3 Work Included 2 1.4 Related Work Specified Elsewhere 2 PART 2 PRODUCTS 3 2.1 Pipe and
More informationSECTION CHEMICAL FEED SYSTEM
SECTION 11800 PART 1 GENERAL 1.1 SUMMARY A. This section includes the requirements for the chemical feed system shall be a complete turnkey system inclusive of all necessary fluid handling and ancillary
More informationYOUR SPLASH PAD RESOURCE
1 Index Permits & Inspections Material List Warnings Splash Pad Types Pre-Site Grading Plumbing Schematic Pressure Testing Concrete Preparation and Pour Housing/Nozzle Installation Above Ground Water Feature
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT
SECTION 220529 - HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The General Conditions, Special Conditions and Division 1 through Division 22 as set forth in
More informationA101 S001 1 SUB-BASEMENT 3/16" = 1'-0" SHEET (906) PH (906) FX 2 S101 NEW CONCRETE WALLS TO FORM WAVE TANK 3' - 0" 5' - 5"
5' - 5" 3' - 0" 2 S0 NEW CONCRETE WALLS TO FORM WAVE TANK 7 SHEET NOTES (906) 487-2303 PH (906) 487-329 FX 9/22/207 :34:03 AM FILE: \\nas2.dcs.it.mtu.edu\sas_homes\desktop\meem wave tank.rvt 7 2' - 4"
More informationUNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:
SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract apply to this Section. 1.2 SUMMARY A. This Section
More informationt y p e V S A S E W A G E P U M P
Pe r fo r m a n ce C h a r t 65 6 55 45 4 35 3 25 2 12 11 1 / 2 11 1 1 / 2 1 9 1 / 2 6% 7% 76% 7 1 HP 1/2 HP HP 76% 7% 6% C u r v e P a g e V S A - 5 1 1 5 R P M M O D E L : V S A - 6 H D I S C H A R G
More informationELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1 SECTION SUPPORTING DEVICES
KNOXVILLE, TENNESSEE SECTION 26 05 29 PAGE 1 PART 1 - GENERAL: 1.01 DESCRIPTION OF WORK: SECTION 26 05 29 A. Extent of supports, anchors, sleeves and seals is indicated by drawings and schedules and/or
More information40'-0" PIPE SUPPORT (TYP.) (SEE DWG. NO. SK-2 OR DWG. NO. SK-4)
SK-1 STANDARD LENGTH 4.301 40'-0" A 6" 2'-0" 9'-0" 9'-0" 9'-0" 9'-0" 2'-0" A 3" OF EXPOSED AT EACH END OF PIPE. PIPE SUPPORT (TYP.) (SEE DWG. NO. SK-2 OR DWG. NO. SK-4) EXPOSED PIPE MINIMUM GAUGE AND THICKNESS
More informationDiffused Aeration Piping Equipment
1.0 General 1.1. The specifications in this section include all components of the Diffused Aeration System with the exception of the individual diffuser units. Refer to additional specification sections
More informationInground Pool Liners
Inground Pool Liners 20 Mil or 30 Mil Pool Liner ALL SIZES AND STYLES AND PATTERNS AVAILABLE PLEASE CALL FOR MEASUREMENT SHEET AND PRICING Pool Safety Stingl Switch When a blockage occurs it shuts down
More informationInground Pool Liners
Inground Pool Liners 20 Mil or 30 Mil Pool Liner ALL SIZES AND STYLES AND PATTERNS AVAILABLE PLEASE CALL FOR MEASUREMENT SHEET AND PRICING Pool Safety Stingl Switch When a blockage occurs it shuts down
More informationInground Pool Liners
Inground Pool Liners 20 Mil or 30 Mil Pool Liner ALL SIZES AND STYLES AND PATTERNS AVAILABLE PLEASE CALL FOR MEASUREMENT SHEET AND PRICING Pool Safety Stingl Switch When a blockage occurs it shuts down
More informationDIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.
PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe and equipment support systems. B. Inserts. 1.02 RELATED SECTIONS A. Section 15890 - Ductwork Supports. 1.03 DEFINITIONS A. Supports: Attachments, hangers,
More informationMAXIMUM TRENCH WIDTH AS REQUIRED SEE MEASUREMENT AND PAYMENT SECTION OF SPECIFICATIONS
REFER TO PAVEMENT PATCHING DETAIL FOR REQUIREMENTS ABOVE FINISHED SUBGRADE EL. MAXIMUM ALLOWABLE WIDTH OF PAVEMENT PATCH, SEE MEASUREMENT AND PAYMENT SECTION OF SPECIFICATIONS MAXIMUM TRENCH WIDTH AS REQUIRED
More informationA. Piping materials shall bear label, stamp, or other markings of specified testing agency.
SECTION 221316- PART 1- GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe, tube, and fittings. 2. Specialty pipe fittings. 1.2 INFORMATIONAL SUBMITTALS A. Field quality-control reports. 1.3 QUALITY ASSURANCE
More informationSECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION
SECTION 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 - GENERAL 1.1 SUMMARY A. This section supplements all sections in this division, including pipe, fittings, valves, and connections for sprinkler
More informationNORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section AUTOMATIC CONTROL VALVE INSULATED ENCLOSURE (HOT BOX)
Section 15959 PART 1 GENERAL 1.01 SUMMARY This Section includes the furnishing and the installation of Automatic Control Valve Insulated Enclosures (Hot Boxes) for control valves installed on water lines
More informationREQUIREMENTS FOR INDOOR INSTALLATION OF PADMOUNTED TRANSFORMERS
REQUIREMENTS FOR INDOOR INSTALLATION OF PADMOUNTED TRANSFORMERS Introduction An applicant applying for permanent electric service who opts to have the padmounted transformers installed inside his building
More informationSECTION COOLING TOWER
PART 1 GENERAL 1.1 SECTION INCLUDES A. Mechanical induced draft Cooling Tower B. Controls C. Ladder and handrails 1.2 REFERENCES SECTION 23 65 00 COOLING TOWER A. ANSI/AFBMA 9 - Load Rating and Fatigue
More informationDIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM
DIVISION 22 PLUMBING PART 1 GENERAL 1.01 DESCRIPTION A. Provide a complete system of soil, waste, and vent piping to fixtures and equipment, including traps, floor drains and cleanouts, extending to a
More informationNORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS
PART 1 GENERAL 1.01 SUMMARY Section 15140 PIPE HANGERS, This Section includes the furnishing and subsequent installation of: A. Pipe and equipment hangers, supports, and associated anchors B. Equipment
More informationSECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT
SECTION 23 05 29 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of work
More informationSection 7: Specifications
Section 7: Specifications 29 31 Building Boundary of Clear Area See Note # 1 8' Shrubs 8' Concrete Pad Equipment 8' TRAVELED WAY M Meter Pedestal 8' Curb Protective Vehicle Posts (Bollards) If Required
More informationBASIC MATERIALS & METHODS
SECTION 15591 BASIC MATERIALS & METHODS 1. SCOPE 1.1 Work Included: 1. SCOPE... 1 2. PIPING SYSTEMS... 1 3. HWS/R PIPING SYSTEM... 2 4. GAS PIPING SYSTEMS... 5 5. PROTECTION OF EXISTING STRUCTURES AND
More informationTable of Contents... 1, 2. (EF) Equipment Floor... VISR EF 102 Water Heater VISR EF 104 Chiller VISR EF 105 End Suction Pump...
VISR Standard Details - TOC VISR-SD File No: T-VISR-SD-00 Supersedes: New Date: 6-Mar-204 Date: New VISR Standard Details: Table of Contents Table of Contents..., 2 (EF) Equipment Floor... VISR EF 0 Tank...
More informationROAD CLOSURE GATE PLAN ESTIMATED QUANTITIES CONCRETE FOOTINGS FOR S. D. DEPT. OF TRANSPORTATION DECEMBER 1996 ELEVATION CABLE TIE DOWN FOOTING
ADMIN. S 1 1 13 199 POST Anchor Bolts (4 Required) 1 Pole Base Plate Footing PLAN POST Chamfer on Footing ESTIMATED QUANTITIES ITEM UNIT QUANTITY Footing & Eyebolt Class M5 Concrete CU.YD. 0.5 The quantity
More informationA. ASTM F Standard Specification for Pressure-rated Polypropylene (PP) Piping Systems.
SECTION 221114 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the water distribution piping system, including potable cold, hot and hot water piping including associated fittings, and specialities
More informationTechnical and Dimensional Data. Saf-T Vent SC
Technical and Dimensional Data Saf-T Vent SC 3"/5" & 4"/7" Concentric Reduced Clearance Double Wall for Special Gas Vent and/or Sealed Combustion Systems Copyright 2003 Saf-T Vent is a registered trademark
More informationSECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 The design guidelines contained herein include the requirements for drainage and vent systems utilized at The University of Texas at Austin. It is the intention of this document to
More informationSECTION WELDED STEEL WATER STORAGE TANKS
SECTION 33 16 20 WELDED STEEL WATER STORAGE TANKS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Elevated tanks. 2. Appurtenances and accessories. B. Related Sections: 1. Section 03 31 20 - Concrete
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT
Page 220529-1 SECTION 220529 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationRoof Replacement. Notes: T-1 (Title Page) 709 Bull Street Columbia, South Carolina. University of South Carolina. Callcott Social Science
Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details S1.0 Safety Anchor Plan Building 709 Bull Street Columbia, 1 10/13 T-1 (Title Page)
More informationSECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
SECTION 260548 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel
More informationDESIGN PACKAGE. COMMONS PARK Twin Falls, Idaho
DESIGN PACKAGE A WATER FEATURE HYDRAULIC DESIGN FOR COMMONS PARK Twin Falls, Idaho P16375-R5 6-16-17 Prepared by FOUNTAIN PEOPLE P.O. Box 807 4600 Highway 123 San Marcos, Texas 78666 SPECIAL DESIGN CONSIDERATIONS
More informationBuilding Permit Application
Building Permit Application Administrative Use Only PARENT PERMIT NUMBER (Required if part of another project) PERMITTEE: PERMITTEE ADDRESS: E-MAIL ADDRESS: ARCHITECT/ENGINEER: ARCHITECT/ENGINEER ADDRESS:
More informationSECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT
SECTION 230548 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Elastomeric Isolation pads. 2. Elastomeric Isolation mounts. 3. [Freestanding] [Restrained] [Freestanding and restrained]
More informationSECTION NON-PENETRATING PORTABLE ROOFTOP SUPPORTS AND WALKWAYS. For best results, display hidden notes to specifier.
SECTION 15062 NON-PENETRATING PORTABLE ROOFTOP SUPPORTS AND WALKWAYS PART 1 GENERAL 1.1 SECTION INCLUDES For best results, display hidden notes to specifier. A. Portable, non-penetrating, rooftop support
More informationProject No
PART 1 - GENERAL 1.1 SECTION INCLUDES A. Seismic Requirements for single rod hanger supports for conduit, pipe and other similar systems. B. Seismic Requirements for trapeze type supports for cable tray,
More informationToll Free Order Line: or Fax: Advantage Leisure Products Ltd. All rights reserved.
Pool Safety Stingl Switch When a blockage occurs it shuts down the pump to prevent injury or death. Works on all single speed pool or spa pumps up to 3 hp. Stock Number: Size: List Price: SR500 Stingl
More informationMODELS: 475 WM & 475 WMSS
Most Dependable Fountains, Inc. OPERATIONS MANUAL MODELS: 475 WM & 475 WMSS Most Dependable Fountains, Inc 5705 Commander Drive Arlington, TN 38002 800-552-6331 FOUNTAINS, MOST DEPENDABLE FOUNTAINS, INC.
More informationMASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping inside the building.
SECTION 221413 - FACILITY STORM DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following storm drainage piping inside the building. 1. Pipe, tube, and fittings. 2. Special pipe
More informationNOTES: 2. THE PIPING CONFIGURATION IS ILLUSTRATIVE. FIELD ADJUSTMENTS TO ACCOMMODATE ACTUAL CONDITIONS ARE ALLOWED WITH APPROVAL FROM JEA.
RTU PANEL GENERATOR W/BELLY FUEL TANK CORE HOLE INTO WET WELL AND INSTALL FLOAT SWITCH WIRE IN CONDUIT ELECTRIC METER ATS PANEL GENERATOR I/O PANEL CONTROL PANEL NOTES: 1. THE CLEARANCES SHOWN AROUND THE
More informationBid Package 22A Plumbing Systems
Bid Package 22A Plumbing Systems The successful Subcontractor acknowledges and agrees to the requirements set forth by this bid package and its descriptions and in conjunction with all other Construction
More informationUPGRADES TO WATER TREATMENT SYSTEMS AT CITY OF GUELPH SPLASH PADS PART A HANLON CREEK PARK AND PART B NORM JARY PARK Reference Number: 12-088 A D D E N D U M NO.1 The following shall form part of the tender
More informationMcDuff WTP High Service Pump Replacement
T E C H N I C A L M E M O R A N D U M 642-03 MCDUFF WTP HIGH SERVICE PUMP REPLACEMENT 642-03 McDuff WTP High Service Pump Replacement PREPARED FOR: PREPARED BY: Capital Budget Planning Craig Jones DATE:
More informationSECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS
SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and
More informationAll our products Quality Assurance QUALITY Ensure quality control and it strive for the following:
ALTOWS COMPANY ABOUT US ALTOWS CO. is a premium supplier of top quality piping components and fittings which include various pipes, tubes, threaded fittings, flanges, fasteners, bars, rods etc. Our products
More informationSECTION FACILITY STORM DRAINAGE PIPING
SECTION 22 1413 FACILITY STORM DRAINAGE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationSECTION GROUNDING AND BONDING
SECTION 16060 GROUNDING AND BONDING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationSECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT
SECTION 230548 - VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary
More informationCITY OF ANDERSON BUILDING AND CODES 601 South Main Street
CITY OF ANDERSON BUILDING AND CODES 601 South Main Street Plan Review Notes (STREET ADDRESS) ANDERSON, SC Plan Review Number: Building Plans prepared by: Plans Signed by: Project Name: Plans Received:
More informationCONSTRUCTION OF ELEVATED WATER TANK & WATER WELL VAULT INTERNATIONAL CAMPUS AUGUST 2018
CONSTRUCTION OF ELEVATED WATER TANK & WATER WELL VAULT INTERNATIONAL CAMPUS AUGUST 2018 E S SEPTIC TANK N W BASKETBALL COURT ELEVATED WATER TANK MAN HOLE WATER WELL VAULT 1 0 SITE PLAN OF NO NAME INITL
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationEast Central College HANSEN HALL LEVEL 300/400 RENOVATIONS CONSTRUCTION PACKAGE
SECTION 220529 - HANGERS AND SUPPORTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationThe University of Texas Health Science at Houston Swimming Pool Renovation Project Phase 1: New Filter System
The University of Texas Health Science at Houston Swimming Pool Renovation Project Phase 1: New Filter System 1.0 Scope of Work Pool Gallons: Approximately 557,000 gallons Turn Over Rate: 6 Hours Pump
More information1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.
INC. ENGINEERING/CONSTRUCTION/MANUFACTURING /WWW.CONTAINWATER.COM SPRINGS, TEXAS. 78620 MODEL SPECIFICATION FOR CONTAIN WATER INC. 30 DEGREE ROOF CORRUGATED STEEL WATER STORAGE Part 1 GENERAL 1.01 SECTION
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC PIPES AND TUBES
SECTION 23 20 00 - HVAC PIPES AND TUBES PART 1 - GENERAL 1.1 SUMMARY: A. Section includes pipe and pipe fittings for: heating water, chilled water, steam and steam condensate, condenser water, glycol,
More information1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.
INC. ENGINEERING/CONSTRUCTION/MANUFACTURING /WWW.CONTAINWATER.COM SPRINGS, TEXAS. 78620 MODEL SPECIFICATION FOR CONTAIN WATER INC. DOME ROOF CORRUGATED STEEL WATER STORAGE TANKS. Part 1 GENERAL 1.01 SECTION
More informationSECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS
SECTION 26 05 26 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationB. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.
SECTION 230529 - HANGERS AND SUPPORTS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Sleeves. 6. Mechanical sleeve seals. 7. Firestopping
More informationSECTION SANITARY WASTE INTERCEPTORS
SECTION 22 13 23 SANITARY WASTE INTERCEPTORS PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable
More informationSection 12 Hydraulics.
Design Guidelines Section 12 Hydraulics. www.canterbury.ac.nz/learningresources Standards in the Design Guidelines Suite Design Standard Guidelines Index: 01 General 02 Architecture 03 Audio Visual 04
More informationANY SPECIFICATION DRAWINGS OR DATED PRIOR TO SEPTEMBER 2015 WILL NOT BE HONORED.
November 30, 2015 Dear STEMC Member and Contractors, Over the years, STEMC has made many changes to its member requirements for new services and specifications associated with those requirements. As a
More informationMODELS: SM & SMSS
Most Dependable Fountains, Inc. OPERATIONS MANUAL MODELS: 410-18 SM & 410-18 SMSS Most Dependable Fountains, Inc 5705 Commander Drive Arlington, TN 38002 800-552-6331 FOUNTAINS, MOST DEPENDABLE FOUNTAINS,
More informationRead Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED
Chapter 17 Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.1.1 Applicability The regulations in this chapter apply to any private potable water supply system where plumbing fixtures are
More informationSECTION PLUMBING SPECIALTIES
PART 1 GENERAL 1.1 SCOPE SECTION 22 20 00 PLUMBING SPECIALTIES A. Work consists of all plumbing work indicated on drawings and specified herein. B. Also included are all fees and permits for installation
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT
SECTION 220529 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationMASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING
SECTION 221316 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following soil and waste, sanitary drainage and vent piping inside the building: 1. Pipe, tube,
More informationC. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationSECTION DUCTS PART 1 GENERAL 1.01 SUMMARY
1 1 1 1 1 1 1 1 0 1 0 1 SECTION 1 DUCTS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Duct Materials.. Insulated flexible ducts.. Single wall spiral round ducts.. Ductwork fabrication.. Duct cleaning.
More informationFig. 1 - Standard Clevis Hanger
Revision 10/24/2007 Fig. 1 - Standard Clevis Hanger Component of State of California OSHPD Approved Seismic Restraints System Size Range Size 1/2" thru 36" pipe. Function Recommended for the suspension
More informationA. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationFiberstars Lighted Laminar Flow Fountains
Fiberstars Lighted Laminar Flow Fountains SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation and operation of Fiberstars Lighted Laminar Flow Fountain. The maximum lighted
More information200 Series In-Slab Pool Fittings
230 Series nti-vortex Plate 2-2 231 Series Sump 2-3 234 Series Sump 2-4 236 Series Sump 2-5 253 Series Overflow 2-6 255 Series Overflow/Drain 2-7 261 Series Vacuum Fitting 2-8 263 Series Eyeball Fitting
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT
SECTION 220529 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Steel pipe hangers and supports. 2. Metal framing systems. 3. Thermal-hanger shield inserts. 4. Fastener systems.
More informationDesign and Construction Standards SECTION HYDRONIC PIPING
SECTION 15510 HYDRONIC PIPING PART 1 GENERAL 1.1 REFERENCES A. ANSI/ASME SEC 9: Welding and Brazing Qualifications. B. ANSI/ASME B16.3: Malleable Iron Threaded Fittings Class 150 and 300. C. ANSI/ASME
More informationElectrical Services Standard Specification Cable Tray Installation. May For ROYAL HOLLOWAY UNIVERSITY OF LONDON
Electrical Services Standard Specification 4.0 - Cable Tray Installation May 2010 For ROYAL HOLLOWAY UNIVERSITY OF LONDON Prepared For The Estates Division By: Hulley & Kirkwood Consulting Engineers Ltd
More informationSECTION GROUND WATER STORAGE TANKS
SECTION 33 16 13 GROUND WATER STORAGE TANKS PART 1: GENERAL 1.01 SCOPE A. Section includes requirements for designing, fabricating, and erecting a welded steel ground storage tank. 1.02 SYSTEM DESCRIPTION
More informationSECTION PLUMBING PIPING
PRT1 GENERL 1.01 SECTION INCLUDES SECTION 22 1005 PLUMBING PIPING Pipe, pipe fittings, specialties, and connections for piping systems. 1. Domestic water. 2. Storm water. 3. Flanges, unions, and couplings.
More informationSECTION HYDRONIC PIPING
PART 1 GENERAL 1.1 REFERENCES SECTION 15510 HYDRONIC PIPING A. ANSI/ASME SEC 9: Welding and Brazing Qualifications. B. ANSI/ASME B16.3: Malleable Iron Threaded Fittings Class 150 and 300. C. ANSI/ASME
More informationVSS S U B M E R S I B L E S E W A G E P U M P S
7 2 9 8 / 2 3 HP % % 64% 7 5 HP HP 5 HP % % C u r v e P a g e V S S - 4 5 R P M M O D E L : V S S - 4 E I M P E L L E R : V S A - 4 C - 2-5 A l s o a p p l i e s t o V S S - 5 E & V S S - 6 E 7 7 65 55
More informationEast Central College
SECTION 221116 - DOMESTIC WATER PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationToll Free Order Line: or Fax: Advantage Leisure Products Ltd. All rights reserved.
Pool Safety Stingl Switch When a blockage occurs it shuts down the pump to prevent injury or death. Works on all single speed pool or spa pumps up to 3 hp. Stock Number: Size: List Price: SR500 Stingl
More informationSECTION PLUMBING SPECIALTIES
SECTION 15430 PLUMBING SPECIALTIES PART 1 GENERAL The requirements of the GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS and Division 1, General Requirements, Apply to the work specified in this section.
More informationGas Station & C Store SECTION CWM Job No
SECTION 211010 - PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in Contract
More informationSECTION SANITARY WASTE INTERCEPTORS
SECTION 22 13 23 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable in the section
More informationStudent Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
SECTION 26 05 48 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel
More information