ABBE LEVEL 3 DIPLOMA IN ON CONSTRUCTION ENERGY ASSESSMENT ABBE LEVEL 3 CERTIFICATE IN DOMESTIC ON CONSTRUCTION ENERGY ASSESSMENT (QCF)

Size: px
Start display at page:

Download "ABBE LEVEL 3 DIPLOMA IN ON CONSTRUCTION ENERGY ASSESSMENT ABBE LEVEL 3 CERTIFICATE IN DOMESTIC ON CONSTRUCTION ENERGY ASSESSMENT (QCF)"

Transcription

1 E LEVEL 3 IPLOM IN ON ONSTRUTION ENERGY SSESSMENT E LEVEL 3 ERTIFITE IN OMESTI ON ONSTRUTION ENERGY SSESSMENT (QF) SMPLE EXMINTION QUESTIONS The purpose of this document is to provide examples of typical questions and how they are presented under the main topics covered in the examination. Please note that these questions have come from past examination papers and may reflect legislation and/or specifications that have since been updated; the main purpose is to give an indication of the level and focus of what to expect. nswers are not provided for these questions. We hope that by reviewing this sample you enter the exam room with more confidence as to what to expect. Good luck! Examination duration: 40 minutes

2 SMPLE QUESTION PPER 1 ategory: uilding onstruction (5 questions) Q1. The drawing shown may be provided to you as part of a design scheme. Which ONE of the following is the correct name for this type of drawing? esign drawing Specification drawing Isometric drawing ross section 2

3 Q2. U-value for an insulated element may need adjusting with a correction factor, to include the effect of thermal bridging. Which ONE of the following statements about such adjustments is NOT correct? correction is needed for wall ties in an insulated cavity wall, unless plastic ties are used correction is needed for a loft hatch in an insulated ceiling; the size of the correction depends on the insulation thickness on the loft hatch correction is needed for recessed lighting in an insulated ceiling, where insulation has been removed to allow for heat dissipation from the light fittings correction is needed for air gaps in the insulation layer of an insulated floor 3

4 Q3. The diagram shows a detached house, which will be built with an integral garage and an attached, thermally separated conservatory. In SP calculations, adjustments to fabric U-values are sometimes needed to take account of the sheltering effect of unheated spaces. Which ONE of the following options correctly identifies the fabric U- value adjustments that are required for this dwelling? The SP assessor must make U-value adjustments to the walls separating the dwelling from the conservatory and from the garage The SP assessor must make U-value adjustments to the walls and doors separating the dwelling from the conservatory and from the garage The SP assessor must make U-value adjustments to the walls and doors separating the dwelling from the garage The SP assessor must make U-value adjustments to the walls separating the dwelling from the garage 4

5 Q4 The drawing shows four different types of hatching that may be used in a construction drawing. Which ONE of the following numbers is the correct symbol for soil? Q5. Which ONE of the following is the default timber fraction for timber frame walls using conventional timber studs? 10% 12.5% 15% 20% 5

6 ategory: uilding Regulations (5 questions) Q6. SP 2009 generates a notional dwelling using reference values. standard air permeability figure is given. Identify the correct air permeability figure from the following: 0.1 m 3 /h.m 2 at 50 Pa 5 m 3 /h.m 2 at 50 Pa 10 m 3 /h.m 2 at 50 Pa 100 m 3 /h.m 2 at 50 Pa Q7. ccording to the omestic uilding Services ompliance Guide; external lighting, when automatically controlled, must NOT exceed: 40 Watts 60 Watts 100 Watts 150 Watts Q8. uilding Regulations specify minimum standards for quality of construction of dwellings. Identify the ONE correct statement from the following options relating to the requirement for pressure testing on a development: On each development, regardless of its size, the pproved ocument requires an air pressure test to be carried out on only one unit of each dwelling type For a development with up to 10 homes of a specific dwelling type, one example of that dwelling type must be tested For a development with more than 4 but not more than 40 homes of a specific dwelling type, two examples of that dwelling type must be tested For a development with more than 40 homes of a specific dwelling type, the proportion to be tested can be reduced if the pressure tests on the first 2 units of that type achieve the standard 6

7 Q9. The following statements relate to the design limits for envelope standards in the pproved document relating to conservation of fuel and power in new dwellings. Which ONE of the following statements is NOT correct? The pproved ocument provides design limits for envelope standards in order to limit heat gains and losses through the fabric of the dwelling You must calculate U-values using the methods and conventions set out in R443, onventions for U-value calculations The pproved ocument provides Limiting U-values for both the area weighted average of an element (eg for all walls) and also for individual elements (the worst individual wall) The pproved ocument provides Limiting U-values as an alternative to the calculation of the dwelling's ER, allowing you to show compliance without confirming that the ER meets the TER Q10. ccording to the Energy Performance of uildings (ertificates and Inspections) (England and Wales) (mendment No 2) Regulations 2008 (SI 2008/2363), which ONE of the following statements correctly summarises the responsibilities of uilding ontrol when accepting TER and ER calculations for new dwellings? uilding ontrol may accept a certificate issued by an accredited energy assessor as evidence of compliance with regulation 17 of the uilding Regulations The assessor must be accredited for the category of building concerned uilding ontrol may accept a certificate issued by an accredited energy assessor as evidence of compliance with all aspects of Part L. The assessor must be accredited for the category of building concerned uilding ontrol may accept a certificate issued by any accredited energy assessor as evidence of compliance with regulation 17 of the uilding Regulations 2000 uilding ontrol should check all TER and ER calculations regardless of the competence of the person submitting them 7

8 ategory: Services (5 questions) Q11. To achieve optimum efficiency, a central heating system based on a boiler should be provided with a boiler interlock. For a normal (not combi) boiler, which ONE of the following definitions is correct? boiler interlock is present when the system includes a room thermostat, cylinder thermostat and TRVs boiler interlock is present when the system includes a room thermostat, cylinder thermostat and programmer boiler interlock is present when the system is wired so that the central heating pump turns off when there is no demand for heat boiler interlock is present when the system is wired so that the central heating boiler turns off when there is no demand for heat Q12. Low energy lighting is a possible energy saving technology that may be incorporated in designs for new dwellings. Which, if any, of the two statements is/are correct? Statement 1: Replacing all standard GLS (incandescent) lighting in a dwelling with low energy lighting will lower the carbon dioxide emissions from the dwelling. Statement 2: Replacing all standard GLS (incandescent) lighting in a dwelling with low energy lighting will increase the energy used for heating in the dwelling. Only statement 1 is correct Only statement 2 is correct oth statements are correct Neither statement is correct 8

9 Q13. Identify the ONE correct statement from the options below, describing the predicted carbon dioxide emissions from heating systems using different fuels. Except for the fuel used, the systems are equivalent in terms of their energy efficiency, installed in the same property, and used under standard occupancy conditions. The predicted carbon dioxide emissions from an LPG (Liquefied Petroleum Gas) fired heating system are greater than the predicted carbon dioxide emissions from a mains gas heating system The predicted carbon dioxide emissions from an LPG fired heating system are less than the predicted carbon dioxide emissions from a mains gas heating system The predicted carbon dioxide emissions from an LPG fired heating system are the same as the predicted carbon dioxide emissions from a mains gas heating system The predicted carbon emissions from the system fuelled by LPG and the system fuelled by mains gas are different but from the information provided it is not possible to decide which is greater Q14. Which ONE of the following heating and hot water systems can only be specified with an off-peak electricity tariff? Electric PSU in heated space Immersion heater in hot water cylinder Electric underfloor heating in timber floor Panel, convector or radiant heaters Q15. When identifying the boiler efficiency for a gas boiler, according to the SP 2009 document what is the preferred source of these details? The product characteristics database ertified manufacturer s data Table 4a of the SP 2009 document necdotal evidence from the designer 9

10 ategory: Software protocol (SP conventions) (5 questions) Q16. SP conventions require the primary and secondary heating systems in a dwelling to be separately identified. hoose the ONE statement about secondary heating in SP that is NOT correct. In SP the secondary heating system is always based upon a room heater If there is no provision for secondary heating, and the installed main system comprises electric storage heaters only, the SP is calculated without specifying a secondary heating system If there is no provision for secondary heating, and the installed main system is a mains gas boiler and radiator system, the SP is calculated without specifying a secondary heating system If there is a chimney and hearth present, capable of supporting an open fire, and no other secondary heating is present, the SP is calculated assuming a solid fuel appliance provides secondary heating 10

11 Q17. You are presented with the drawing shown below as part of a scheme. What scale would you expect this drawing to be in? 1:1 1:100 1: :1 11

12 Q18. Which ONE of the following does NOT form part of the definition of a living area according to SP 2009? Marked on plan as lounge or living room Largest public room Includes any cupboards accessed directly from the lounge or living room an extend over more than one storey 12

13 Q19. The diagram shows a section taken from the side of a proposed detached house with dimensions. Which, if any, of the two statements is/are correct? Statement 1: In SP calculations, the upper floor storey height is the total height between the ceiling surface of a given storey and the ceiling surface of the storey below. Statement 2: The storey heights for this house are: ground 2.7m, first 2.325m. Only statement 1 is correct Only Statement 2 is correct oth statements are correct Neither statement is correct 13

14 Q20 Refer to the diagram below showing the rear elevation of a detached house with three door types evident. Each door type has a different glazed area as follows: Type 1: glazed area 20% (top panels only) Type 2: glazed area 90% (top and bottom panels) Type 3: glazed area 65% (single panel) ccording to the SP protocols for treating glazed doors as windows, select the ONE answer from the following options which most accurately describes the correct treatment of doors in this example: oor type 3 is treated as a window in the SP calculation None of these door types are treated as windows in the SP calculation oor types 2 and 3 are treated as windows in the SP calculation ll three door types are treated as windows in the SP calculation 14

15 SMPLE QUESTION PPER 2 ategory: uilding onstruction (5 questions) Q1. Which ONE of the following correctly identifies the material labelled as in the drawing? Timber joists supporting floorboards Insulation Solid concrete Reinforced concrete Q2. You are assessing a domestic property with a timber framed external wall with 38mm timbers at 600mm centres. What is the default fraction of timber in the wall when used for calculation of U values according to R 443:2006? 5% 15% 50% 90% 15

16 Q3. Which ONE of the following is the default timber fraction for timber frame walls using conventional timber studs? 10% 12.5% 15% 20% Q4 When defining a U-value for a window, which ONE of the following options states the correct method? Include the full window frame, but disregard glazing Include the full window frame, and only the thickest layer of glass Include the whole window opening in the wall including glass and frame Include only the glazing and disregard the frame Q5. Which ONE of the following methods would you NOT employ to reduce heat loss? Eliminate air barriers within constructions lign insulation layers in adjacent building elements Keep services within insulated envelope Reduce repeating thermal bridges 16

17 ategory: uilding Regulations (5 questions) Q6. What is the limiting U-value specified for a wall in L1? Q7. pproved ocument L1 recommends a design air permeability of 10m 3 /(h.m 2 ) at a given pressure difference. This pressure difference is: 0.5 Pa 5 Pa 50 Pa 500 Pa Q8. The calculation of the dwelling's Target Emission Rating (TER) includes a Fuel Factor, to allow for the fuel that will be used to heat the dwelling. Which ONE of the following statements about the TER calculation is NOT correct? If the dwelling will be heated by mains gas, the fuel factor used in the TER calculation is 1.0 If the dwelling will be heated using electricity, the primary heating fuel assumed for the notional dwelling is electricity If the dwelling will be heated by an electric heat pump, the fuel factor used in the TER calculation is the same as for other systems using grid electricity If the dwelling will be heated by LPG, the fuel factor used in the TER calculation is

18 Q9. SP 2009 generates a notional dwelling using reference values. Which of the following is NOT a correct reference value for this notional dwelling? Size and shape is the same as actual dwelling The fraction of the property used as living area is the same Windows and glazed doors have a U value of 2.0 W/m 2 K Roofs have a U value of 2.0 W/m 2 K Q10. The omestic uilding Services ompliance Guide provides guidance on lighting in dwellings. Identify the ONE correct statement from the following options: The guidance makes no stipulations regarding external lighting for dwellings The guidance specifies that 30% of fixed light fittings in dwellings should be low energy fittings The calculation of the dwelling's ER assumes that 50% of the installed lighting is low energy Light fittings whose supplied power is less than 5 circuit-watts are excluded from the overall count of the total number of light fittings ategory: Services (5 questions) Q11. When considering the energy performance of ground source heat pumps: The ratio of heat energy output to the electrical energy consumed is usually greater than 1 The ratio of heat energy output to the electrical energy consumed is usually less than 1 The ratio of heat energy output to the electrical energy consumed is usually equal to 1 The ratio of heat energy output to the electrical energy consumed is usually greater than 10 18

19 Q12. You are assessing a dwelling design that has provision for a range cooker. What type of range cooker would NOT be included in the SP 2009 calculation? Twin burner range cooker/boiler Single burner range cooker/boiler Single burner ranger cooker/water heater Single burner dry heat range cooker Q13. Which ONE of the following abbreviations can be described as a fan driven system, often providing ventilation to a dwelling from the loft space? MEV PIV PEV MIV Q14. Which ONE of the following is the least responsive heating system? Modern (slimline) storage heaters Fan storage heaters On peak electric underfloor heating in timber floor Manual feed solid fuel (mineral or wood) boiler Q15. onsider the following statements about heating controls in SP and choose the ONE correct statement. central heating system using a standard boiler is said to have a boiler interlock if it is fitted with a room thermostat and a space heating programmer The absence of a boiler interlock is modelled in SP by increasing the assumed heating efficiency for the system central heating system using a standard boiler is said to have a boiler interlock if it is fitted with TRVs, a space heating programmer and a bypass central heating system using a combi boiler is said to have a boiler interlock if it is fitted with a room thermostat 19

20 ategory: Software protocol (SP conventions) (5 questions) Q16. Your design assessment is missing some information. Which ONE of the following are you allowed to use a default value for? Hot water cylinder insulation Living room area Number of sheltered sides Room in roof height Q17. The drawing shown may be provided to you as part of a design scheme. Which ONE of the following is the correct name for this type of drawing? Map view Orientation drawing Site plan irds eye view 20

21 Q18. Referring to the diagram showing a section taken from the side of a proposed detached house, what are the ground and first floor storey heights for this house? Ground floor 2.7, first floor Ground floor 2.7, first floor 2.55 Ground floor 2.925, first floor Ground floor 2.7, first floor

22 Q19. Referring to the diagram showing the ground floor plan of a detached house, select the ONE correct description of how the living area fraction is calculated for this house. The floor area of the lounge and dining room divided by the total floor area of the house The floor area of the lounge and hall divided by the total floor area of the house The floor area of the lounge divided by the floor area of the ground floor of the house The floor area of the lounge divided by the total floor area of the house 22

23 Q20 In the SP treatment of solar shading by blinds, curtains and external shutters, which ONE of the following provides the greatest degree of shading? Light coloured curtain or roller blind White external shutter, with window closed Net curtain, covering whole window ark-coloured external shutter, with window closed 23

This draft design submission has been prepared from plans and specifications and may not reflect the property as constructed.

This draft design submission has been prepared from plans and specifications and may not reflect the property as constructed. This Design Draft submission has been prepared by a Competent, registered with Faero Ltd. Faero Ltd. Scheme membership covers Criterion 1 of this checklist, that is, the requirement for the predicted carbon

More information

SAP Calculations. Project: Adjacent to Number 7 Dince Hill Close Exeter, Whimple, Devon, EX5 2TE

SAP Calculations. Project: Adjacent to Number 7 Dince Hill Close Exeter, Whimple, Devon, EX5 2TE SAP Calculations Client: Stowford Homes Project: Adjacent to Number 7 Dince Hill Close Exeter, Whimple, Devon, EX5 2TE Contact: Jerry Gilby Coast 2 Coast Property Assessment jerryg@c2cpropertyassess.co.uk

More information

The effect of Building Regulations (Part L1 2002) on existing dwellings

The effect of Building Regulations (Part L1 2002) on existing dwellings GENERAL INFORMATION LEAFLET 70 The effect of Building Regulations (Part L1 2002) on existing dwellings Information for installers and builders for extensions and alterations in England and Wales " Insulation

More information

Full SAP Calculation Printout

Full SAP Calculation Printout Users Ref: Property: 7869-0001-0001158 Standard, 01, Example, example, example Full SAP Calculation Printout Issued on: 29.October.2008 Prop Type Ref: TER: 22.13 DER: 22.10 SAP Rating: 80 C SAP Energy

More information

SAP Calculations. Project: Conversion of the Royal Oak Inn OSWESTRY, Kinnerley Dovaston, Shropshire, SY10 8DP

SAP Calculations. Project: Conversion of the Royal Oak Inn OSWESTRY, Kinnerley Dovaston, Shropshire, SY10 8DP SAP Calculations Mr P Mellor Project: Conversion of the Royal Oak Inn OSWESTRY, Kinnerley Dovaston, Shropshire, SY10 8DP Contact: Julie Lock Energy Surveyor - Shropshire Council 01743 258748 Predicted

More information

The calculation procedure will continue to be known as SAP 2005 but the SAP version number is incremented from 9.80 to 9.81.

The calculation procedure will continue to be known as SAP 2005 but the SAP version number is incremented from 9.80 to 9.81. Amendments to SAP 2005 (version 9.81) April 2008 The calculation procedure will continue to be known as SAP 2005 but the SAP version number is incremented from 9.80 to 9.81. 1 Very little overshading The

More information

Building Control. A Guide to Compliance When Designing Domestic Extensions

Building Control. A Guide to Compliance When Designing Domestic Extensions Building Control Technical Guidance Leaflet No. 18 Approved Document L1B 2010 Conservation of Fuel and Power This leaflet is one of a series produced by the Hertfordshire Building Control Technical Forum

More information

Project name SOLAR HOUSE 80/50 Project summary

Project name SOLAR HOUSE 80/50 Project summary http://lowenergybuildings.org.uk Project name SOLAR HOUSE 80/50 Project summary Project Description Projected build start date 01 Mar 2010 Projected date of occupation 19 Jul 2010 Project stage Under construction

More information

SAP Calculations. M & T Homes Limited. Project: Plot 2, Wombourne Road Wombourne, Swindon, South Staffordshire, DY3 4NB

SAP Calculations. M & T Homes Limited. Project: Plot 2, Wombourne Road Wombourne, Swindon, South Staffordshire, DY3 4NB SAP Calculations Client: M & T Homes Limited Project: Plot 2, Wombourne Road Wombourne, Swindon,, DY3 4NB Contact: Geoff Williams ECCO2 Limited geoffwilliams@ecco2ltd.co.uk Building Regulation Compliance

More information

CHAPTER 13: Sustainability

CHAPTER 13: Sustainability CONTENTS 13.1 THE CODE FOR SUSTAINABLE HOMES 13.2 LOW CARBON / LOW ENERGY HOMES 13.3 AIR TIGHTNESS AND ROBUSTNESS 13.4 RENEWABLE ENERGY SOURCES Chapter 13 FUNCTIONAL REQUIREMENTS FUNCTIONAL REQUIREMENTS

More information

Energy efficiency and the Code for Sustainable Homes

Energy efficiency and the Code for Sustainable Homes CE290 Energy efficiency and the Code for Sustainable Homes Level 3 Also available: Energy efficiency guidance for level 4 Energy efficiency guidance for levels 5 and 6 Contents 1. Introduction 3 1.1 The

More information

Dwellings Energy Assessment Procedure (DEAP) for Building Regulations Compliance. Kevin O Rourke Head, Built Environment Sustainable Energy Ireland

Dwellings Energy Assessment Procedure (DEAP) for Building Regulations Compliance. Kevin O Rourke Head, Built Environment Sustainable Energy Ireland IBCI Conference 2007: Bunratty Shannon Shamrock Hotel 22-23 March 2007 Dwellings Energy Assessment Procedure (DEAP) for Building Regulations Compliance Kevin O Rourke Head, Built Environment Sustainable

More information

SAP. Standard Assessment Procedure for assessing the energy performance of dwellings. As Designed SAP. Redstone House

SAP. Standard Assessment Procedure for assessing the energy performance of dwellings. As Designed SAP. Redstone House SAP Standard Assessment Procedure for assessing the energy performance of dwellings As Designed SAP Redstone House Redstone Road, Narberth SA67 7ES SAP Standard Assessment Procedure for assessing the energy

More information

6.4 Insulation of pipes, ducts and vessels. 6.6 Mechanical ventilation and air conditioning. 6.7 Commissioning building services

6.4 Insulation of pipes, ducts and vessels. 6.6 Mechanical ventilation and air conditioning. 6.7 Commissioning building services domestic energy contents 2007 Contents 6.0 Introduction 6.1 Carbon dioxide emissions 6.2 Building insulation envelope 6.3 Heating system 6.4 Insulation of pipes, ducts and vessels 6.5 Artificial and display

More information

Regulations Compliance Report

Regulations Compliance Report Regulations Compliance Report Approved Document L1A 21 edition assessed by Stroma FSAP 29 program, Version: 1.5..32 Printed on 17 February 213 at 2:25:45 Project Information: Assessed By: Behdad Yazdani

More information

Building Regulation Compliance Page 1 of 11

Building Regulation Compliance Page 1 of 11 Building Regulation Compliance Page 1 of 11 Survey Reference: RNW/09.97 Prop Type Ref: New Build Property: Plot 9, High Trees, The Bailey, Skipton, BD23 SAP Rating: 84 B CfSH Results Version: ENE1 Credits:

More information

6.4 Insulation of pipes, ducts and vessels. 6.6 Mechanical ventilation and air conditioning. 6.7 Commissioning building services

6.4 Insulation of pipes, ducts and vessels. 6.6 Mechanical ventilation and air conditioning. 6.7 Commissioning building services domestic energy contents 2007 Contents 6.0 Introduction 6.1 Carbon dioxide emissions 6.2 Building insulation envelope 6.3 Heating system 6.4 Insulation of pipes, ducts and vessels 6.5 Artificial and display

More information

Project name Gentoo Retrofit Bid 1 Project summary Refurbishment of 2no. Semi Detached houses using Passivhaus principles

Project name Gentoo Retrofit Bid 1 Project summary Refurbishment of 2no. Semi Detached houses using Passivhaus principles http://lowenergybuildings.org.uk Project name Gentoo Retrofit Bid 1 Project summary Refurbishment of 2no. Semi Detached houses using Passivhaus principles Project Description Projected build start date

More information

SAP Report Submission for Building Regulations Compliance

SAP Report Submission for Building Regulations Compliance SAP Report Submission for Building Regulations Compliance Client: BAUHU Project: 1 Final Design South, Plug & Play Modular House Contact: Guy Smith Easy EPC admin@easyepc.org Report Issue Date: 16/03/2017

More information

Department of Finance and Personnel Building Regulations (Northern Ireland) October 2012

Department of Finance and Personnel  Building Regulations (Northern Ireland) October 2012 Department of Finance and Personnel www.dfpni.gov.uk Building Regulations (Northern Ireland) 2012 G u i d a n c e Technical Booklet F1 Conservation of fuel and power in dwellings October 2012 Contents

More information

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Energy Performance Certificate 1 Harts Court Hartshill Oakengates TELFORD TF2 6AL Dwelling type: Detached house Date of assessment: 30 August 2011 Date of certificate: 09 September 2011 Reference number:

More information

Approved Document L1A and L2A

Approved Document L1A and L2A Guide to: Approved Document L1A and L2A For England and Wales NEWBUILD Conservation of fuel and power APPROVED DOCUMENTL1A Conservation of fuel and power APPROVED DOCUMENTL2A Talk to the SIG360 team at

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Woodall, Harthill SHEFFIELD S26 7YJ Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Detached house 1 June 2011 6 June 2011 0598-3002-6376-8779-2900

More information

The effect of Building Regulations (Part L1 2002) on existing dwellings

The effect of Building Regulations (Part L1 2002) on existing dwellings Energy Efficiency Best Practice in Housing The effect of Building Regulations (Part L1 2002) on existing dwellings Information for installers and builders for extensions and alterations in England and

More information

> Performance requirements: Part L UK vs Energiesprong vs Passivhaus.

> Performance requirements: Part L UK vs Energiesprong vs Passivhaus. > Performance requirements: Part L UK vs Energiesprong vs Passivhaus. Introduction The purpose of this paper is to highlight and compare the difference in performance requirements between UK Building Regulations

More information

SAP Calculations. Acheson Construction. Project: Plot 8, Neils View Maiden Newton. Contact: James Frampton Trinity Architecture

SAP Calculations. Acheson Construction. Project: Plot 8, Neils View Maiden Newton. Contact: James Frampton Trinity Architecture SAP Calculations Client: Acheson Construction Project: Plot 8, Neils View Maiden Newton Contact: James Frampton Trinity Architecture james@trinarch.com CODE FOR SUSTAINABLE HOMES - CfSH November 2010 Page

More information

SAP: The Essential Guide For Dwelling Designers And Architects By Mike Andrews

SAP: The Essential Guide For Dwelling Designers And Architects By Mike Andrews SAP: The Essential Guide For Dwelling Designers And Architects By Mike Andrews The overall aim is to give the dwelling designer a better understanding of what SAP is, how it is used to demonstrate compliance

More information

# Limitations Topic Conventions Issue date

# Limitations Topic Conventions Issue date SAP 2012 Conventions 01 September 2018 (v 8.0) Conventions apply to SAP 2012 throughout the UK except where otherwise indicated under 'Limitations'. Conventions applied for design stage calculations submitted

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Mid-floor flat 09 December 2008 11 December 2008 0018-7944-6282-5358-5070 57 m²

More information

Energy Performance Certificate

Energy Performance Certificate 6, Grafton Road, Brigstock, KETTERING, NN14 3EY Dwelling type: Semi-detached house Reference number: 2638-4081-7286-4856-7984 Date of assessment: 27 June 2016 Type of assessment: RdSAP, existing dwelling

More information

49 YEW TREE DRIVE, LAMMACK, BLACKBURN, BB2 7DW. 195,000 GENERAL DESCRIPTION Semi detached house with brick and rendered front, side & rear under a slate roof with a double storey outrigger to rear. Includes

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Woodend, Dwelling type: Detached house Cenarth, Date of assessment: 22 July 2008 NEWCASTLE EMLYN, SA38 9JP Date of certificate: 22 July 2008 Reference number: 0744-2892-6738-0428-4161

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Moreton Lough Church Road Longhope Glos GL17 0LA Dwelling type: Detached house Date of assessment: 28 June 2011 Date of certificate: 13 July 2011 Reference number: 2588-3095-6296-4779-9940

More information

(81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

(81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Energy Performance Certificate Locka Old Hall Cottage Dwelling type: Detached bungalow Arkholme Date of assessment: 01 March 2011 CARNFORTH Date of certificate: 01 March 2011 LA6 1BD Reference number:

More information

Dwelling Energy Assessment Procedure (DEAP) Survey Guide

Dwelling Energy Assessment Procedure (DEAP) Survey Guide Dwelling Energy Assessment Procedure (DEAP) Survey Guide VERSION 2.1 DEAP is the official procedure for the calculation of energy performance of dwellings in Ireland for the purposes of producing Building

More information

Energy Performance Certificate

Energy Performance Certificate 127, Weydon Hill Road, FARNHAM, GU9 8NZ Dwelling type: Semi-detached house Reference number: 8576-7826-4900-2097-2922 Date of assessment: 23 June 2016 Type of assessment: RdSAP, existing dwelling Date

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 6, Chynoweth Gardens, Gulval PENZANCE TR18 3DL Dwelling Type: Semi-detached bungalow Date of Assessment: 05/03/008 Date of Certificate: 05/03/008 Reference Number: 8618-647-4330-4585-500

More information

One Size Fits All. Insulation A GUIDE TO BUILDING REGULATIONS / STANDARDS COMPLIANCE FOR NEW DWELLINGS USING STRUCTURAL INSULATED PANELS (SIPS)

One Size Fits All. Insulation A GUIDE TO BUILDING REGULATIONS / STANDARDS COMPLIANCE FOR NEW DWELLINGS USING STRUCTURAL INSULATED PANELS (SIPS) Insulation Second Issue April 2018 One Size Fits All A GUIDE TO BUILDING REGULATIONS / STANDARDS COMPLIANCE FOR NEW DWELLINGS USING STRUCTURAL INSULATED PANELS (SIPS) Low Energy Low Carbon Buildings 2

More information

SAP WorkSheet: New dwelling design stage

SAP WorkSheet: New dwelling design stage User Details: Assessor Name: Marco Valori Stroma Number: STRO7212 Software Name: Stroma FSAP 29 Software Version: Version: 1.4..72 Address :, Fife, KY11 4HT 1. Overall dwelling dimensions: Property Address:

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Burway House, 3 Westholme Park, Hazler Road, CHURCH STRETTON, SY6 7AF Dwelling type: Detached house Date of assessment: 23 December 2010 Date of certificate: Reference number:

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 101 Kidmore Road Caversham READING RG4 7NH Dwelling type: Detached house Date of assessment: 11 January 2012 Date of certificate: 11 January 2012 Reference number: 0991-2849-6291-9692-6045

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 34, Garner Close, Barwell, LEICESTER, LE9 8NG Dwelling type: Detached house Date of assessment: Date of certificate: Reference number: 0972-3897-6985-9120-5971 Type of assessment:

More information

BRE RdSAP v9.91 software QSAP v9.0.0 April 2012

BRE RdSAP v9.91 software QSAP v9.0.0 April 2012 BRE RdSAP v9.91 software QSAP v9.0.0 April 2012 BREC Accreditation Scheme Part of the BRE Trust Q-SAP software & EPC changes Data Entry New data items Option for U-value entry Recommendations Reduced text

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Little Barn Marley Heights HASLEMERE GU27 3LU Dwelling type: Detached house Date of assessment: 9 March 2009 Date of certificate: 10 March 2009 Reference number: 8591-6927-5100-0861-1006

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 35, Cumberland Street WOODBRIDGE IP1 4AH Dwelling type: End-terrace house Date of assessment: 16 January 009 Date of certificate: 16 January 009 Reference number: 8681-659-5100-966-7096

More information

(81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

(81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Energy Performance Certificate 4 Walnut Court Dwelling type: Detached house Brook Street Date of assessment: 28 January 2011 Soham Date of certificate: 28 January 2011 ELY Reference number: 0681-2838-6494-9329-4151

More information

NEARLY ZERO ENERGY BUILDING RETROFIT SAP Dr Luisa Brotas

NEARLY ZERO ENERGY BUILDING RETROFIT SAP Dr Luisa Brotas NEARLY ZERO ENERGY BUILDING RETROFIT SAP 2012 Dr Luisa Brotas 4-8 July 2016 SAP EDITION 2012 SAP is the Government sstandard Assessment Procedure for Energy Rating of Dwellings. Assesses the energy performance

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 46, Tamar Avenue TORQUAY TQ2 7LP Dwelling type: Semi-detached house Date of assessment: 1 May 2009 Date of certificate: 1 May 2009 Reference number: 0698-6021-6215-6811-4014

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Flat 59 Richmond Court 200 Sloane Street LONDON SW1X 9QU Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Mid-floor flat 24 February

More information

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Energy Performance Certificate 8 Glan Yr Afon Cwmbach ABERDARE CF44 0DD Dwelling type: Detached house Date of assessment: 09 September 2011 Date of certificate: 09 September 2011 Reference number: 8599-6231-8640-5201-8902

More information

Project Description. Projected build start date 15 Aug 2011 Projected date of occupation 19 Dec Existing external wall construction

Project Description. Projected build start date 15 Aug 2011 Projected date of occupation 19 Dec Existing external wall construction http://lowenergybuildings.org.uk Project name Redlands Project summary Deep retrofit of 1955 brick house in Devon based on EnerPHit standard. House had old gas boiler, double glazing, cavity wall insulation

More information

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Energy Performance Certificate 42, Drake Avenue TEIGNMOUTH TQ14 9NA Dwelling type: Detached house Date of assessment: 15 November 2011 Date of certificate: 18 November 2011 Reference number: 9191-3838-6298-9399-6615

More information

conservation of fuel and power

conservation of fuel and power The conservation of fuel and power Approved document Conservation of fuel and power in new dwellings 2013 edition for use in England* main changes in the 2013 edition This approved document, Approved Document

More information

SAP 2012 Conventions. 31 August 2017 (v 7.01) Conventions apply to SAP 2012 throughout the UK except where otherwise indicated under 'Limitations'.

SAP 2012 Conventions. 31 August 2017 (v 7.01) Conventions apply to SAP 2012 throughout the UK except where otherwise indicated under 'Limitations'. SAP 2012 Conventions 31 August 2017 (v 7.01) Conventions apply to SAP 2012 throughout the UK except where otherwise indicated under 'Limitations'. Conventions applied for design stage calculations submitted

More information

SAP Calculations. Draft SAP Project: Bungalow Undercliff. Contact: Sandra Hardwick

SAP Calculations. Draft SAP Project: Bungalow Undercliff. Contact: Sandra Hardwick SAP Calculations FitzArchitects Draft SAP 08.12.2015 Project: Bungalow Undercliff Contact: Sandra Hardwick Predicted Energy Assessment Page 2 of 16 Bungalow, Undercliff, Cleadon, SR6 7UX Dwelling type:

More information

Contact Details: Phone Fax . Work Description: New Building Extensions Refurbishment Change of Use. Yes No Method:

Contact Details: Phone Fax  . Work Description: New Building Extensions Refurbishment Change of Use. Yes No Method: BCA Section J- Energy Efficiency Deemed- to- Satisfy Provisions Assessment Sheet 1. Project Overview Client Name: Address: Contact Person: Contact Details: Phone Fax Email Project: Work Description: New

More information

Conversion SAP Checklist

Conversion SAP Checklist Version 1.0 April 2016 Conversion SAP Checklist Call us today on 0800 917 8922 to speak with an adviser or visit Conversion SAP Checklist This checklist is split into three sections. Section 1 Project/dwelling

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 33, Boundary Place, PLYMOUTH, PL6 7FD Dwelling type: Mid-terrace house Date of assessment: Date of certificate: Reference number: 8110-6232-7299-4469-4902 Type of assessment:

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Flat 65 Colnmore Court, 13, Meath Crescent Dwelling type: Top-floor flat LONDON Date of assessment: August 011 E 0QF Date of certificate: August 011 Reference number: Type

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Apartment 3 Porter House 36, Woodcutter Close WALSALL WS1 3QU Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Ground floor flat

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 6 Bruce Close Dwelling type: Mid-terrace House WISBECH Date of assessment: 16 May 011 PE13 QA Date of certificate: 13 July 011 Reference number: 8959-6335-8760-786-499 Type

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 5, Fountain Crescent Dwelling type: Semi-detached house WOTTON-UNDER-EDGE GL12 7LD Date of assessment: Date of certificate: Reference number: Type of assessment: 08 September

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 106b, Auchinleck Close Dwelling type: Semi-detached House DRIFFIELD Date of assessment: 13 September 010 YO5 9HE Date of certificate: 15 August 011 Reference number: 860-6731-8600-5887-4996

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 12, Grenville Road Dwelling type: Detached house PADSTOW PL28 8EX Date of assessment: Date of certificate: Reference number: Type of assessment: 23 November 2010 23 November

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 10, The Woodlands Tatenhill, BURTONONTRENT DE13 9QZ Dwelling Type: Detached house Date of Assessment: 13/08/2007 Date of Certificate: 10/09/2007 Reference Number: 85336428492092977096

More information

BRE Client Report. Ofgem Deemed Scores Methodology. Prepared for: Ofgem 9 Millbank, London, SW1P 3GE. BRE Watford, Herts WD25 9XX

BRE Client Report. Ofgem Deemed Scores Methodology. Prepared for: Ofgem 9 Millbank, London, SW1P 3GE. BRE Watford, Herts WD25 9XX BRE Client Report Ofgem Deemed Scores Methodology Prepared for: Ofgem Date: 26 Oct 2016 Report Number: P103305-1001 Issue: 4 BRE Watford, Herts WD25 9XX Customer Services 0333 321 8811 Prepared for: Ofgem

More information

Expired Report. (92-plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

Expired Report. (92-plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Energy Performance Certificate 27, Studcross, Dwelling type: Detached house Epworth, Date of assessment: 26 July 2008 DONCASTER, DN9 1DS Date of certificate: 26 July 2008 Reference number: 8309-3564-5920-1726-6383

More information

BUILDING REGULATIONS PART L 2011 PROVISIONS & COSTS (STANDARD 3-BED SEMI-D, CIRCA 120 SQM)

BUILDING REGULATIONS PART L 2011 PROVISIONS & COSTS (STANDARD 3-BED SEMI-D, CIRCA 120 SQM) BUILDING REGULATIONS PART L 2011 PROVISIONS & COSTS (STANDARD 3-BED SEMI-D, CIRCA 120 SQM) NOV 2012 OVERALL PRIMARY ENERGY, CO 2 & RENEWABLES TGD L 2005-2013 2005 2007/8 2011 2013? CO 2 % 100% 69% 46%

More information

Harnett House The Old Post Office NEBO Conwy LL26 0TB

Harnett House The Old Post Office NEBO Conwy LL26 0TB This has been produced for Harnett House The Old Post Office NEBO Conwy LL26 0TB Tel: 01690 750288 www.wmepc.co.uk Mob: 07891103562 enquiries@wmepc.co.uk Old Post Office, Nebo, LLANRWST, LL26 0TB Dwelling

More information

Related party disclosure: Boiler and radiators, mains gas 35 m² 120 kwh/m² per year 20 kg/m/m per year Mid-floor flat

Related party disclosure: Boiler and radiators, mains gas 35 m² 120 kwh/m² per year 20 kg/m/m per year Mid-floor flat Energy Performance Certificate Northern Ireland 117 Lisburn Road BELFAST BT9 7AF Energy Efficiency Rating Date of assessment: Date of certificate: Reference number: Accreditation scheme: Assessor's name:

More information

The Building Regulations, Part L (2013)

The Building Regulations, Part L (2013) Latest Release November 2013 Technical Briefing Note The Building Regulations, Part L (2013) www.xtratherm.com Technical Briefing Note The Building Regulations, Part L (2013) The latest revisions to energy

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Flat 26 Castle Quay, Castle Lane, BEDFORD, MK40 3FE Dwelling type: Midfloor flat Date of assessment: 16 July 2008 Date of certificate: Reference number: 07 November 2008

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Detached house 3 February 2010 3 February 2010 155 m² This home's performance

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 31, St. Johns Road, GUILDFORD, GU2 7UQ Dwelling type: Semidetached house Date of assessment: Date of certificate: Reference number: 87316129428033845026 Total floor area:

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Stoneyrigg House Dwelling type: Detached House Stoney Rigg Date of assessment: 4 January 01 HALTWHISTLE Date of certificate: 01 February 01 NE49 9JJ Reference number: 148-7064-6319-995-940

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 34, Sandygate Park Road, Dwelling type: Detached bungalow SHEFFIELD, S10 5TY Date of assessment: 03 July 2008 Date of certificate: Reference number: 05 July 2008 0678-4033-6283-4288-9074

More information

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Estimated energy use, carbon dioxide (CO ) emissions and fuel costs of this home

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Estimated energy use, carbon dioxide (CO ) emissions and fuel costs of this home Energy Performance Certificate 8, Vishwell Road CARDIFF CF5 1GE England & Wales EU Directive 00/91/EC Dwelling type: Mid-terrace house Date of assessment: 01 December 011 Date of certificate: 05 December

More information

Building Typology Brochure England September 2014

Building Typology Brochure England September 2014 Building Typology Brochure England September 2014 Disclaimer The sole responsibility for the content of this publication lies with the authors. It does not necessarily reflect the opinion of the European

More information

(81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

(81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Energy Performance Certificate 14, Home Farm Court Dwelling type: Semi-detached house Castle Gresley Date of assessment: 20 February 2012 SWADLINCOTE Date of certificate: 20 February 2012 DE11 9JA Reference

More information

SAP Calculations. Project: SITE 1 PHASE 2 MOYLAGH MEADOWS, MOYLAGH ROAD, BERAGH. Contact:

SAP Calculations. Project: SITE 1 PHASE 2 MOYLAGH MEADOWS, MOYLAGH ROAD, BERAGH. Contact: SAP Calculations Client: CHIEFTAN HOMES Project: SITE 1 PHASE 2 MOYLAGH MEADOWS, MOYLAGH ROAD, BERAGH Contact: Building Regulation Compliance Page 2 of 29 Property Reference: MOYLAGH MEADOWS, BERAGH Survey

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 4, Hartwood Crescent WOLVERHAMPTON WV4 5QN Dwelling type: Detached house Date of assessment: 23 June 2010 Date of certificate: 23 Jun 2010 Reference number: 8906 8277 3729

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 94, Hereford Road Dwelling type: Detached house MONMOUTH Date of assessment: 16 November 011 NP5 3HH Date of certificate: 16 November 011 Reference number: 9468-7917-669-9839-3914

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 17 Healdswood Street SUTTON-IN-ASHFIELD Nottinghamshire NG17 3FR Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Semi-detached

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate The Old School Dwelling type: Semi-detached house Immingham Road Date of assessment: 7 April 010 Habrough Date of certificate: 8 April 010 IMMINGHAM Reference number: 0579-853-6643-930-785

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 10b Shop Lane Brewood STAFFORD ST19 9EB Dwelling type: Date of assessment: Date of certificate: Reference number: Type of assessment: Total floor area: Detached bungalow

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Flat 97, Dwelling type: Mid-floor flat Admirals House, Date of assessment: 04 April 2008 Gisors Road, Date of certificate: 04 April 2008 SOUTHSEA, PO4 8GY Reference number:

More information

Working with landlords and tenants to tackle fuel poverty: aka improving energy efficiency

Working with landlords and tenants to tackle fuel poverty: aka improving energy efficiency Working with landlords and tenants to tackle fuel poverty: aka improving energy efficiency Sustainable Homes / EPCs national averages Energy Analysis CROHM People as well as properties Questions Established

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 11, Holcroft Drive Dwelling type: Detached house Abram Date of assessment: 08 April 2009 WIGAN Date of certificate: 08 April 2009 WN2 5YP Reference number: 0488-4033-6224-4661-2070

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Gwaelod, Cwmllinau, MACHYNLLETH, SY20 9NT Dwelling type: Detached bungalow Date of assessment: 10 October 2008 Date of certificate: Reference number: 82950305822072964083

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 106, Tiverton Road Dwelling type: Detached house LOUGHBOROUGH Date of assessment: 13 July 011 LE11 RZ Date of certificate: 19 July 011 Reference number: 880-4578-389-7596-5393

More information

Project name Old Dover Road Project summary Whole house retrofit and formation of new habitable roof structure

Project name Old Dover Road Project summary Whole house retrofit and formation of new habitable roof structure http://lowenergybuildings.org.uk Project name Old Dover Road Project summary Whole house retrofit and formation of new habitable roof structure Project Description Projected build start date Projected

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Hi-View Old Park Road Ketley Bank TELFORD TF2 0DG Dwelling type: Detached bungalow Date of assessment: 12 August 2008 Date of certificate: 14 August 2008 Reference number:

More information

BERS Pro Plus 4.2 New Features and Modelling Changes. Holger Willrath Solar Logic October 2011

BERS Pro Plus 4.2 New Features and Modelling Changes. Holger Willrath Solar Logic October 2011 BERS Pro Plus 4.2 New Features and Modelling Changes Holger Willrath Solar Logic October 2011 BERS Pro Plus V4.2 New Features and Modelling Changes Holger Willrath Solar Logic This document may not be

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Atlantic View, 1, Fore Street St. Dennis, ST. AUSTELL Cornwall PL6 8AD Dwelling Type: End-terrace house Date of Assessment: 10/1/007 Date of Certificate: 10/1/007 Reference

More information

Guidance on U Values from Domestic Heating Design Guide

Guidance on U Values from Domestic Heating Design Guide Guidance on U Values from Domestic Heating Design Guide The following U Values are from the Domestic Heating Design Guide, and the complete publication is available for purchase from members of the Domestic

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 13, Bowood Park, Dwelling type: Detached bungalow Lanteglos, Date of assessment: 19 February 008 CAMELFORD, PL3 9LA Date of certificate: 19 February 008 Reference number:

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Brookside Rand MARKET RASEN Lincolnshire LN8 5NJ Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Detached house 24 October 2008

More information