BASICS OF LIGHTNING PROTECTION
|
|
- Nathaniel Dalton
- 5 years ago
- Views:
Transcription
1 sabo BASICS OF LIGHTNING PROTECTION Lightning is an important phenomenon, which one cannot resist without danger, but which is easily led if one lets it have its way. It possesses millions of volts, capable of shattering insulating obstacles, but flows meekly through small-diameter conductors. Since it is curious during its descent to explore neighboring metal structures and conductors, where, rightly or wrongly, it hopes to find an easier outlet, it is wiser to pave its way with appropriate interconnections than to bar its way with obstacles that are ineffective. The essential idea behind every Lightning Protection System is to avoid situations in which these forces get diverted to vulnerable points of a building / installation. In other words the Lightning Protection Systems should be able to provide the favourable path for the lightning to go to the ground thereby preventing it to strike any unwanted area. Every year lightning causes millions of Rupees worth of damages to structures and electronics as a result of over voltages and thermal damages. The awesome natural phenomenon of lightning, which strikes the earth an estimated 6,000 times per minute, is an ever present and unpredictable enemy. It is a danger to humanity and a danger to all the equipments and structures. THE EFFECTS OF LIGHTNING: The main effects of Lightning are as follows: i. Thermal effects: These effects are linked to the quantity of charges involved when lightning Strikes. For materials with high resistivity, they cause various melting points at the places of impact. On poorly materials, a large amount of energy is released in the form of heat. The moisture they contain causes sudden overpressure that may result in explosion. ii. Effect due to arching: The resistivity of the soil makes earthing resistant and therefore unable to prevent a sudden rise in the facility s potential when lightning current passes through it. This creates differences in potential between the various metal parts. iii. Electrodynamics effects: These effects are produced if part of the path along which the lightning current travels is within the magnetic field of another part. This may produce repulsion and attraction forces when lightning travels through conductors situated close to each other. iv. Induction effects: Induction effects are often the biggest challenge to protection systems. When lightning approaches a site, it creates a magnetic flux that produces high, and sometimes destructive, induced voltages. v. Indirect effects: Offset potential or pace voltage. Dispersion of lightning currents in the soil depends on the nature of the terrain. A heterogeneous soil may create dangerous differences of potential between two neighboring points.
2 sabo Introduction to Lightning Protection Technology Lightning Conductor s function is to divert to itself a lightning discharge, which might otherwise strike a vulnerable part of the structure/facility to be protected. Before proceeding with the detailed design of a lightning protective system, the following essential steps should be taken: i. Decide whether or not the structure needs protection and, it, so, what are the special requirements. ii. Ensure a close liaison between the architect, the builder, the lightning protection system engineer so that the appropriate design is made which provides the complete protection cover to the building / facility. iii. Ensure the correct the procedures for erection, commissioning, testing and future maintenance. Conventional Lightning Arrester These are oldest concept in Lightning protection. The ability of the conventional rod is to concentrate electric field under the electric storm condition around the corona. The corona is observed in the near vicinity of the tip, as the field concentration created by its geometric shape will decrease rapidly with distance, provided the tips are really sharp. The conventional rod offers a cone of protection based upon its installed height above the structure.it assume a positive angle from projections and structural components within are deemed to be protected against direct strikes. Angles of 45 are the general case protection angle for these rods. With a Conventional Lightning Rod of height 1 meter installed at the roof top of the building will be able to give an area of protection of meters sq. So for a building with top area of say 5 m x 5 m = 25 sq meter, approximately 8-9 Lightning Conductors shall have to be used. However, limitations of this concept particularly manifest themselves when applied to very tall structures. Normally Conventional rod is commanded non-effective above m height and continuously reduces the protection angles with increased structure height. Also when we are installing these lightning conductors on the building we have to install maximum nos. of conventional rods to cover maximum area and each rod requires separate down conductor with earthing and each earthing has be bonded with each other. This makes the system very complicated and costly. It also will require more maintenance and typically considering the Building protection against the lightning, the use of multiple numbers of rods defaces the buildings. Advanced Technology based on Ion generator The result of many years of ongoing field research is the Advanced Lightning protection system. This unit provides the design engineer with an air termination relatively free of space charges, which is capable of creating ionization and which concentrate electric field to release free electron on the approach of a lightning leader. As a result mostly only one lightning conductor is required against a large number of Conventional Lightning conductors. This Advanced Lightning conductor is a dynamic device which has a very strong central ion generating system that is able to generate ions and requires no external source of power supply. This remarkable terminal has the ability to concentrate only the electric field, which occur in microsecond time slot as the leader charges approach to ground. The unique lightning protection system has been designed to provide repetitive electrical discharge only during the time of approach of the downward Leader. If we have to install this protection device to a certain Building, we require only One Lightning conductor, only one down conductor with 3 earth pit and which will protect the entire buildings, monuments and surrounding area from direct lightning damages. CONSTRUCTION: Metal Used: Stainless steel, wheather proof, chemical reaction proof and non corrosive, making it a fit and forget installation. Lightning Intercepting Rod: It is again a stainless steel portion which intercepts lightning. Electro-atmospheric Energy Block: The portion within the high tension stroke generator Ion Electrodes: These provides high tension strokes which are produced in high tension stroke generator to form ion. Earth Connector: Stainless steel portion which transfers the lightning discharge to ground conductor. Pipe Connection Adaptor: Portion through which lightning rod is connected to 2 pipe which is used to as shaft to raise the lightning conductor.
3 TESTS AND CERTIFICATIONS: sabo 1. METU Electric Electronic high tension Lab test certificate as per NFC Lightning conductor lab of Beijing Lightning protection device test center 3. GOST certificate 4. CE certificate 5. ISO certificate All LIVA lightning conductors are serial numbered and each carry 30 years Warranty. In house test certificate for each lightning conductor can also be submitted on request. Live Test Video is also available. PROTECTION RADIUS: Lightning conductor is categorised based on area or radius within which it provides protection. Radius of protection of lightning conductors is calculated based on following formula derived by NFC : Rp= h(2d-h)+δl(2d+δl) Where Rp Radius of protection in a horizontal plane situated at a vertical distance h of lightning conductor h - Height of top of lightning conductor above area to be protected D - Lightning advancement step or leaping interval of lightning along the way. D=20m for Level I protection, D=30m for Level II, D=45m for Level III protection and D=60m for Level III protection as per NFC standard. ΔL Distance to catch lightning in ΔT period ΔT Early Ionisation time period / Initiation advance time / Early Streamer Warning Time ΔL (m) = V (m/µsec) X ΔT (µsec) For calculation purpose, V to be considered as 1 m/µsec. So, higher ΔT active reaction time of lightning conductor is better. Lightning conductors with higher ΔT intercepts lightning faster and provides wider protection area. It is recommended to used lightning conductors with ΔT > 60 µsec. Level of protection: It is defined as the risk of lightning strike on a structure. It depends upon the various factors like Dimensions of building, structural & environmental coefficients, structure contents & occupancy, lightning density or number of lightning or thunderstorm days, etc.
4 sabo C=C2.C3.C4.C5
5 sabo Steps to ensure Correct Lightning Protection System with the Advanced Ion generating Lightning Conductor Step 1 Calculation of Risk Assessment or The Protection Level for the Building / structure The Lightning risk is assessed using various criteria for determining the protection need and required protection level. The various factors taken into consideration are as follows: - --Environment of building (Coefficient C1) -- Type of construction (Coefficient C2) -- Structure Contents (Coefficient C3) -- Structure occupancy (Coefficient C4) --Consequence of lightning strikes (Coefficient C5) Separate application form is enclosed for user to send us the data so that the protection level can be calculated. This risk assessment / protection level calculation is done as per the International Standards i.e. NFC, IEC etc. In case the user needs the details, the same can provided on request.
6 LIVA LIGHTNING CONDUCTOR APPLICATION FORM sabo CUSTOMER DETAILS: Customer: Address: Dimension of the Building Length of the building: Date: Contact Name: Telephone: Fax: Place/city where building is located Width of the Building: Height of the building: ENVIRONMENTAL COEFFICIENT (Tick the Appropriate Box) Surrounded by structure or tress of the same height or higher : Surrounded by Smaller Structure : Isolated: No other structure within a distance equal to 3 times height : STRUCTURAL COEFFICIENT (Tick the Appropriate Box): Metallic Common Flammable Roof Walls STRUCTURAL CONTENTS COEFFICIENT OF THE BUILDING (Tick the Appropriate Box): No value : Standard Value or normally flammable : High value or particularly Flammable : Exceptional value, irreplaceable or highly flammable, explosive : STRUCTURE OCCUPANCY OF THE BUILDING (Tick the Appropriate Boxes): Unoccupied : Normally Occupied : Difficult Evacuation : LIGHTNING CONSEQUENCE (Tick the Appropriate Boxes): Service Continuity not required : Consequences on the environment : Service continuity required without consequences on the environment : Detail of any other structure/mast etc installed on the roof:
7 Step 2: Ensure the correct selection of the Advanced Lightning Protection Conductor sabo Protection against direct lighting strikes is designed to capture the lighting impact, channel it and discharge it to the earth for a particular dimensional area of the structure. After evaluating the lightning risk and choosing the protection level, the second phase involves choosing the kind of Lightning Conductor which shall be able to cover the required dimensions. The following is the table that defines the radius of protection that can be achieved by the various models of Lightning Conductor. One model out of these have to be selected which can cater to the protection Level calculated in Step 1 and as per this level is able to cover the dimensions to be protected. On the basis of the data received from the customer as per the step 1, the radius of the protection for the building is calculated as per the table given below: - ORDER CODE LENGTH (MM), WEIGHT (KG) PACKING DIMENSIONS(M M) ΔT (µsec) PROTECTION RADIUS (M) AT 4M. LEVEL IV LEVEL I LEVEL II LEVEL III LAP-DX MM, 5KG 250*250* LAP-AX MM, 5KG 170*170* LAP-BX MM, 4.8KG 170*170* LAP-BX MM, 4.2KG 130*130* LAP-CX MM, 2.4KG 130*130* LAP-CX MM, 2.3KG 130*130* ESE CUM PIEZOELECTRIC ADVANCE LIGHTNING CONDUCTOR LAP-PEX MM, 15KG 160*160* Example: - Suppose the parameter, which we have selected for the building protection, is as below: - Length of the building = 30 m Width of the building = 30 m Height of the building = 5 m Suppose the Level of Protection on the basis of the calculation comes to be as Protection Level - I and radius of protection required is 43 m to provide complete protection to the building. Then if we use the LAP CX 040 model to install at a 4 m height above the roof of the building, then the radius of the protection will be 39 m, which will, not able to provide the complete protection to the building. So we have to suggest the installation of LAP CX 070 lightning conductor at height of 4 m to cover a radius of 47 m so that it will be able to provide the complete protection for the building which has a radius of 43 m.
8 Step 3: Using correct procedures for Erecting, commissioning, testing and future maintenance. sabo 1. As per NFC standard, if width of building is more than 2 times height of the building or building height is more than 28m, then 2 down conductors should be routed from the nearest opposite path of the lightning conductor. 2. Care should be taken in routing the down conductor. It should be routed through the straight and shortest path to earth and also such that all gas pipes, water pipes, wires & cables, etc. should be minimum 1-2m far from it. Sharp bends should be avoided. In any case, bends should have radius of 20cm. External open routing of down conductor is better. 3. In case, metallic pipes / wires /cables are unavoidable then it should be separated by placing them inside a metallic screen which should extend 1m beyond the point of crossing. Such metallic screen should be connected to down conductor. 4. Down conductors should be attached to the side wall of the structure to be protected by means of 2-3 fixings per m. All the down conductors are also connected by same material. 5. Drilling on down conductors should be avoided. 6. Each down conductor should be routed to Rubber or PVC pipe or sleeves in order to avoid risk of impact. 7. When external routing of down conductor is impracticable, then a dedicated duct should be made. Such duct should not be more than 2000sq.mm. If it is more than it or in case other wires, pipes / cables also pass through it then insulated non inflammable duct should cover down conductor. 8. When outside of the building or structure has a metal cladding or stone or glass curtain walls then the down conductor should be attached behind the cladding to the concrete wall or the load bearing structure. In such cases, conductive cladding components and supportive structure must be bonded to the down conductor at the top and bottom ends. 9. If external structure is completely metallic like a telecom or transmission tower and if electrical continuity is there, then, it is not necessary to use separate down conductor. Steel metallic structure can be used as down conductor as they are conductive and their internal resistance is <0.01Ohm. In such cases, ESE lightning conductors should be connected directly to the metallic frame which at the ground level is connected to earth termination system. In such cases, equipotential bonding should properly be done. 10. Down conductor should be earthed at minimum 2-3m apart from building and other earthing. Down conductor should be buried by minimum 1 feet below the ground. Non corrosive earthing compound should be poured below and above the down conductor to avoid corrosion. All the joints should be exothermically welded to avoid any weak joints and increasing life of complete lightning protection system. Preferred Installation Points: It is preferred to install lightning conductor over the topmost portion of the structure to be protected. However, the architectural aspects should be taken into consideration for fixing location of lightning conductor.
9 SPECIFICATIONS OF LAP-CX 070 ADVANCED ACTIVE ESE ION GENERATING TYPE LIGHTNING PROTECTION SYSTEM sabo Complete Lightning Protection System consists of following: 1. Active ESE Early Streamer Emission Air Terminal 2. Elevation Shaft / mast for raising Air terminal minimum 2m above the top of the structure to be protected. Ideally lightning air terminal should be installed at 4m height above the structure to be protected so that complete protection radius capacity of air terminal can be utilized. 3. Down conductor 4. Lightning counter 5. Earthing
10 sabo ADVANCED ACTIVE ION GENRATING ESE EARLY STREAMER EMISSION AIR TERMINAL / LIGHTNING CONDUCTOR LAP-CX070 SPECIFICATIONS: 1. Stainless steel material body, 700mm long and 3.1 Kg nett weight with pointed tip. 2. Based on Active Early Streamer Emission principle and consists of Ion Generator. 3. High early streamer warning time of ΔT31 µsec. 4. Provides protection radius of 72m in Level IV area / 64m in Level III area/ 55m in Level II area/ 47m in Level I at 4m height in accordance with NFC standard. 5. METU Electrical & Electronics test report as per NFC standard. 7. In each lightning conductor Serial number, model no., CE mark, hologram & OEM name is printed. 8. Every lightning conductor carries 30 years warranty. 9. Internal last inspection report of manufacturer will be provided with every serial numbered lightning arrester, if required. 10. Sigma test report 11. Temperature withstand test of -40ºC to +125ºC. 12. QA technic conformity certificate 13. TS EN ISO 9001:2008 certificate 14. BS EN ISO 14001:2004 certificate 15. Certificate of registration from World Intellectual Property Organisation 16. CE certification 17. Testable by means of external tester. 18. Designed as per NFC standard. 17. Suitable for all types of lightning discharges. 19. Suitable for all whether and climatic conditions and can be used in any terrain. 20. No use of battery or power source is required. Elevation Rod: The Advance lightning conductor height may be increased by means of an elevation rod of GI/ SS/ FRP with GI/Aluminium. The lightning conductor tip should be at least 2 meters higher than the highest point of the building that it protects, including antenna, cooling towers, roofs, tanks, etc. The Down conductor is attached to the Advance Lightning conductor by a connecting system located on the support rod. This connecting system consists of suitable mechanical devices providing long-lasting contact. The Down conductor should comply with the data as below: Down Conductor Material Remarks Minimum Dimensions Bare/Tin plated electrolytic Recommended for its good Strip: 30 x 2mm Copper conductivity and corrosion resistance Round section: 8mm Dia 18/ stainless steel Recommended in certain corrosive environments Strip: 30 x 2mm Round section: 8mm Dia A 5/L To be used on aluminum surfaces (cladding, curtain walls) Strip: 30 x 3mm Round section: 10mm Dia When Advance lightning conductors protect open areas such as playing fields, golf courses, swimming pools, camping sites, etc., they should be installed on specific supports such as lightning poles, pylons or any other nearby structures which enables in Advance lightning conductor to cover the maximum area to be protected.
11 sabo LIGHTNING COUNTER Lightning counter is of 6 digits of stainless steel material and have IP65 protection. It also comes in testable/ SMS / options. It is used to provide the information of no. of lightning strikes our lightning protection system has safely discharged. It should be installed at eye level. Technical specifications: Range: to Current discharge capacity >1KA Conductor size: 2.5sq.mm. to 70 sq.mm. Temp: - 50ºC to + 80ºC Degree of Protection: IP 65 / SMS transmission device needed to be installed in case lightning discharge records are needed in remote computer or mobile automatically during lightning strike. The device immediately send the or sms as desired in case of lightning event.
12 LIGHTNING CONDUCTOR & TESTABLE LIGHTNING COUNTER TESTER sabo
13 sabo TEST CLAMP / JOINT: Each down conductor should have a test joint for disconnecting it with earth for measuring the earth resistance. It should be installed generally at 2m height above the ground level. EARTHING: Each earth should consist following: 1. Copper bonded rod 17.2mm dia 1.8m long of 254 microns 1no. 2. NABL tested EREC having resistivity of Ώ-m 20kg 3. Earth chamber of 300mm approx. of CI / concrete / Brick / Polyplastic should be used as earth pit cover. Polyplastic earth pit is preferred since it can withstand all climatic conditions. 3 sets of above earthing should be made each minimum 2m apart and joined by 30*2mm / 8mm dia bare copper rope / 30*3.5mm dia braided copper cable. Suitable non corrosive clamps for connecting strip or cable to copper bonded rods may also be used. All the nuts and bolts should be of stainless steel. Exothermic welding should be done for connecting all joints of strip / cable / rod. POLYPLASTIC EARTH PIT CHAMBER (SABO-PEPC) MAIN FEATURES: Factory- built long holes for accessing pipes easily at site Made of heavy duty polyethylene for extra durability. Resistant materials- assuring long life. Green top cap matches the environment. DIMENSIONS At Top : 10 inches (254mm) At Bottom : 13 inches (330mm) Height : inches (260mm)
14 LIGHTNING CONDUCTOR INSTALLATION DETAILS WITH /SMS OPTION sabo
15 sabo
16 sabo LIGHTNING CONDUCTOR INSTALLATION ACCESSORIES
SECTION LIGHTNING PROTECTION SYSTEM
SECTION 16670 - LIGHTNING PROTECTION SYSTEM PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationInstallation Guide TSP MODEL 20/30/40/50/60
Installation Guide TSP MODEL 20/30/40/50/60 TerraStreamer TSP ESE Terminal Installation Guide Table of Contents Warranty... 2 Supplied Items... 3 TerraSteamer TSP Early Streamer Emission (ESE) Terminals...
More informationSECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 28 05 26 GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY SPEC WRITER NOTE: Delete // // if not applicable to project. Also delete any other item or paragraph
More informationSECTION FACILITY LIGHTNING PROTECTION
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 41 00 FACILITY LIGHTNING PROTECTION SPEC WRITER NOTE: Delete between //----//if not applicable to project. Also delete any other item or paragraph not applicable
More informationEarthing in electrical network purpose, methods and measurement
Earthing in electrical network purpose, methods and measurement Earth / Ground Conductive ground whose electrical potential at each point is set equal to zero, It is a conductor which provides a low impedance
More informationTender No.:- RITES/CO/B&A/EE/CUK- Gulbarga/External/E-2/2012.
Amendment No. 1. Sub. : Tender: Supply, Erection, Testing & Commissioning of 11kV/440 V substation, Transformers, DG Sets, HT/ LT panels, HT/LT Cables, Street Lighting etc at University Campus at Khadaganchki
More informationRepair Maintenance Hangar Phase II August 2010 SECTION LIGHTNING PROTECTION SYSTEM PART 1 GENERAL
SECTION 16601 LIGHTNING PROTECTION SYSTEM PART 1 GENERAL 1.1 SCOPE A. Furnish and install all materials and labor required to provide a complete functional lightning protection and common ground system
More informationComplies with NF C Standard
Complies with NF C 17-102 Standard Who is LPI? Lightning Protection International Pty Ltd (LPI) is a fully owned Australian manufacturer and supplier of direct strike lightning, surge & transient protection
More informationSpecification Lightning Protection Systems
Specification Lightning Protection Systems General: Summary A) This Section specifies the lightning protection system for the building(s) or structure(s). This system provides safety for the building and
More informationUNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:
SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract apply to this Section. 1.2 SUMMARY A. This Section
More informationEssex County College - West Essex Campus Addition And Renovations dlb # / 11-14
SECTION 270526 - GROUNDING AND BONDING FOR COMMUNICATIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationSABO EARTHING SOLUTION
SABO SABO EARTHING SOLUTION The installation and maintenance of an effective low resistance earthing system is essential due to the following- - Efficiently dissipate heavy fault currents and electrical
More informationSECTION GROUNDING
SECTION 16450 GROUNDING PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies general grounding and bonding requirements of electrical and telecommunication installations for personnel safety, equipment
More informationA. Product Data shall be provided for each type of product indicated.
32 31 13 CHAIN LINK FENCES AND GATES SECTION 1 GENERAL 1.1 SUMMARY This Section includes the following: 1. Chain Link Fences 2. Gates for Chain Link Fences. See electrical specifications for electrical
More informationPARTICULAR SPECIFICATION E11: GENERAL ELECTRICAL EARTHING AND LIGHTNING PROTECTION
E11 : General Electrical Earthing and LIGHTNING Protection PARTICULAR SPECIFICATION E11: GENERAL ELECTRICAL EARTHING AND LIGHTNING PROTECTION 1 2009-05-12 Review of Mechanical / Electrical and Control
More informationSession Two: SANS 10313:2010 & IEC Part 2 & 3 Explained
Session Two: SANS 10313:2010 & IEC 62305 Part 2 & 3 Explained T.J. Manas Managing Director Pontins (Pty) Ltd SANS Code 10313:2010 Protection against Lightning Physical Damage and Life Hazard The South
More informationGeneral instructions on lightning protection for shelters
928 General instructions on lightning protection for shelters About 1.5 million lightning incidents are registered in Germany each year. Lightning is fascinating to watch, but also extremely dangerous.
More informationA. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).
16450 GROUNDING ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 05 26 An optional keynote to the
More informationWind Power Solutions. Company Registration No: Vat Registration No.:
Wind Power Solutions Foundation Grounding and Construction, Bonding, Power Connections, Surge Protection, and Lightning Protection ERICO offers a complete range of foundation grounding and construction,
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards
Date Description of Change Pages / Sections Modified ID 6/15/16 Updated format, division title, and removed references to other sections. - mgl44 A. Summary This section contains design criteria for the
More informationSECTION GROUNDING AND BONDING
SECTION 16060 GROUNDING AND BONDING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationElectrical Services Standard Specification Cable Tray Installation. May For ROYAL HOLLOWAY UNIVERSITY OF LONDON
Electrical Services Standard Specification 4.0 - Cable Tray Installation May 2010 For ROYAL HOLLOWAY UNIVERSITY OF LONDON Prepared For The Estates Division By: Hulley & Kirkwood Consulting Engineers Ltd
More informationSECTION CHAIN-LINK FENCES AND GATES 02821/1
SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/1 PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Chain-Link Fences: 2. Gates: horizontal slide or swing. 3. Fences installed where
More informationSECTION EARTHING AND EARTH FAULT PROTECTION
SECTION 16660 PART 1 - GENERAL 1.01 DESCRIPTION A. The work to be performed includes, but is not necessarily limited to, all work involved with the construction and assembly of a complete electrical earthing
More informationCignal-owned Tower Sites Tower Operations & Rigging Policy
Cignal-owned Tower Sites Tower Operations & Rigging Policy June 2016 Table of Contents 1 Introduction... 3 2 Process for Equipment Addition or Amendment... 4 2.1 Application for Equipment Addition or Amendment...
More informationComplies with NF C Standard
Complies with NF C 17-102 Standard LPI Product Offering Lightning Protection International Pty Ltd Lightning Protection International Pty Ltd is a fully owned Australian manufacturer and supplier of direct
More informationCONTENTS. B. System Design and Performance Requirements
16060 Grounding and Bonding This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or
More informationGROUNDING SPECIFICATIONS FOR thermoweld EXOTHERMIC WELDING SYSTEM
GROUNDING SPECIFICATIONS FOR thermoweld EXOTHERMIC WELDING SYSTEM 1. Purpose This specification recommends criteria for use of thermoweld products to provide reliable permanent connections for utility,
More informationGrounding Principles. The need to ground! Definitions. Introduction. Grounding Codes and Standards. 2 Ph:
Introduction Grounding and bonding are an integral part of any modern electrical protection system design. An effective, low-impedance ground system is a key element of this system. It is crucial in ensuring
More informationPetroleum Production and Disposal Facility Static and Lightning Mitigation
Overview Petroleum Production and Disposal Facility Static and Lightning Mitigation Over the years, there have been an inordinately high number of ignitions caused by lightning and static at petroleum
More informationHam Monograph - Tower Grounding
This will be an overview of what I consider to be the minimum requirements for Amateur Radio Station tower grounding. The best document on site grounding is by Motorola 1. Few Hams have the time or the
More informationFoundation Specifications for 3.6-/3.7-Meter Earth Station Antennas
Installation Instructions Foundation Specifications for 3.6-/3.7-Meter Earth Station Antennas Bulletin 37835A Revision E Introduction This document specifies typical foundation characteristics, designs,
More informationSECTION GROUNDING AND BONDING
SECTION 16060 PART 1 GENERAL 1.01 DESCRIPTION A. Section includes requirements for an electrical grounding system, including electrodes, grounding rods, connectors, insulators, equipment grounding and
More informationGB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA
Translated English of Chinese Standard: GB50169-2016 www.chinesestandard.net Buy True-PDF Auto-delivery. Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA UDC P GB 50169-2016
More informationTHE OFFICIAL TRADE JOURNAL OF BICSI
ICT TODAY THE OFFICIAL TRADE JOURNAL OF BICSI January/February 2017 PLUS + + Information Security and ESS in the Age of the Internet of Things + Grounding System Design and Testing for Critical Facilities
More informationSECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS
SECTION 26 05 26 GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide labor, materials, equipment, and incidentals as shown, specified, and
More informationNew Product Flyer Introduction
Dec. 5, 2013 New Product Flyer Introduction Preferred Lightning Protection, Inc. is excited to introduce our newest products and capabilities. Following are several new products with current inventories
More informationWind Power Solutions CADDY ERICO HOFFMAN RAYCHEM SCHROFF TRACER
Wind Power Solutions CADDY ERICO HOFFMAN RAYCHEM SCHROFF TRACER Foundation Grounding and Construction, Bonding, Power Connections, Surge Protection, and Lightning Protection nvent offers a complete range
More informationEarth-termination system for concrete and hybrid towers of wind turbines
Contents Standards for earth-termination systems Earth-termination system Concrete foundation Example of an earth-termination system for a tower www.dehn-international.com Standards for earth-termination
More informationLightning Protection and Trees
Lightning Protection and Trees By Ben Fuest INTRODUCTION This research was established for the purpose of developing a better understanding of lightning protection systems specifically designed to be fitted
More information2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING
2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING E3305.3: now reads The space equal to the width and depth of the panelboard and extending
More information(Condensed from National Electric Code)
WIRING, SPECIFICATIONS, INSPECTION, AND METER INSTALLATION PROCEDURES FOR RESIDENTIAL CUSTOMERS SERVED BY SOUTHWEST ARKANSAS ELECTRIC COOPERATIVE CORPORATION Effective April 1, 1974 Revised February 3,
More informationMATERIAL STANDARD FOR ELECTRICAL HEAT TRACING ORIGINAL EDITION JAN. 1996
MATERIAL STANDARD FOR ELECTRICAL HEAT TRACING ORIGINAL EDITION JAN. 1996 This Standard is the property of Iranian Ministry of Petroleum. All rights are reserved to the owner. Neither whole nor any part
More informationCONDUITS AND FITTINGS
CONDUIT AND FITTINGS Rigid Steel Conduit 3801 Rigid PVC Conduit 3803 HDPE Conduit 3803 Flexible Non Metallic Liquid Tight Conduit Type LFNC-B 3804 PVC Coated Urethane Lined Galvanized Rigid Steel Conduit
More informationEssex County College - West Essex Campus Addition And Renovations dlb # / SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
SECTION 270536 - CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationSECTION CONDUITS AND BOXES PART 1- GENERAL. A. Work covered by this section includes the furnishing and installation of conduits and boxes.
SECTION 16111 CONDUITS AND BOXES 1.01 DESCRIPTION PART 1- GENERAL A. Work covered by this section includes the furnishing and installation of conduits and boxes. 1.02 SUBMITTALS A. The Contractor shall
More informationElectric Service Standards
V: 1 of 6 A. Padmounted Requirements Complete requirements are contained in FPL specifications given to Customers for individual projects. Typical pad mounted transformer requirements include, but are
More informationWhite Paper SV62/E/0712. General instructions on lightning safety for shelters.
www.dehn.de ty due to a lack or insufficient number of lightning-proof-shelters or their insufficient equipment, for example by a relevant notice or a written agreement on limitation of liability, shall
More informationRESIN FILLING TYPE JOINTING KITS FOR LOW VOLTAGE UNDERGROUND CABLES
CEB STANDARD 030-1 : 1996 Specification for RESIN FILLING TYPE JOINTING KITS FOR LOW VOLTAGE UNDERGROUND CABLES CEYLON ELECTRICITY BOARD SRI LANKA Specification for RESIN FILLING TYPE JOINTING KITS FOR
More informationEarth-termination system for concrete and hybrid towers of wind turbines
Contents Standards for earth-termination systems Earth-termination system Concrete foundation Example of an earth-termination system in a concrete tower www.dehn-international.com Standards for earth-termination
More informationDBI-SALA Uni 8 Overhead Horizontal Lifeline Cable System SECTION HORIZONTAL FALL PROTECTION - OVERHEAD CABLE
SECTION 112429.18 - HORIZONTAL FALL PROTECTION - OVERHEAD CABLE PART 1 - GENERAL 1.1 SECTION INCLUDES A. Provide overhead horizontal cable fall protection system, including end anchors, energy absorbers,
More informationCONSTRUCTION SPECIFICATION FOR GROUNDING
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 609 NOVEMBER 2001 CONSTRUCTION SPECIFICATION FOR GROUNDING TABLE OF CONTENTS 609.01 SCOPE 609.02 REFERENCES 609.03 DEFINITIONS - Not Used 609.04 DESIGN
More informationERICO SYSTEM 1000 ESE LIGHTNING PROTECTION PRODUCTS
ERICO SYSTEM 1000 ESE LIGHTNING PROTECTION PRODUCTS Active Protection Pentair is a trusted world leader for providing high-quality grounding solutions, lightning protection and surge protection technologies.
More information6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.
6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4. 6.2 OVERHEAD SERVICES Wiring of any premises for connection
More informationCHAPTER 11 CONDUITS AND FITTINGS
CONDUITS AND FITTINGS CHAPTER 11 CONDUITS AND FITTINGS The standards and requirements for conduits and fittings used for traffic control signal and lighting systems are presented in this chapter. 11.1
More information6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.
6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4. 6.2 OVERHEAD SERVICES Wiring of any premises for connection
More informationFoundation Specifications
Installation Instructions Bulletin 237731 Revision E Foundation Specifications for 3.5-Meter Earth Station Antennas 1.0 INTRODUCTION 1.1 This document specifies typical foundation characteristics, designs,
More informationNYULMC AMBULATORY CARE CENTER FIT-OUT PHASE 1 Perkins & Will Architects PC 222 E 41st ST, NYC Project: Issued for GMP March 15, 2017
SECTION 27 05 26 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationNORTHEASTERN REMC ELECTRIC STANDARDS MANUAL
NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL WARNING Before digging or trenching... Call 811 Indiana Underground Protection Service 1-800-382-5544 AVOID BURIED POWER CABLES 4901 East Park 30 Drive P.O.
More informationMaharashtra State Electricity Distribution Company Limited. SPECIFICATION NO. MMC: MSC-II/Multi Meter box/smc/2018/10 TECHNICAL SPECIFICATION FOR
Maharashtra State Electricity Distribution Company Limited SPECIFICATION NO. MMC: MSC-II/Multi Meter box/smc/2018/10 TECHNICAL SPECIFICATION FOR FOR MULTI-METER BOX SUITABLE FOR HOUSING 4/8/12/18 NOS.OF
More informationNPS/002/001 Technical Specification for Earthing Materials
Version:- 6.0 Date of Issue:- October 2017 Page 1 of 14 NPS/002/001 Technical Specification for Earthing Materials 1. Purpose The purpose of this document is to detail the requirements of Northern Powergrid
More informationA. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.
ALLIANT ENERGY CENTER PAVILIONS Project No. 2013 027 SECTION 27 05 28 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationFoundation Specifications
Installation Instructions Foundation Specifications for 3.6-/3.7-Meter Earth Station Antennas ulletin 37835A Revision L Introduction This document specifies typical foundation characteristics, designs,
More informationOVERHEAD SERVICES - SECONDARY
OVERHEAD SERVICES - SECONDARY Contents - Overhead Services... O-1 General Requirements for Overhead Service... O-2 Names of Parts for Overhead Service... O-3 Service Attachment on an Unguyed Service Mast...
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationPART 7 Technical Specification for Overhead and Underground Service Connection works for the Year
PART 7 Technical Specification for Overhead and Underground Service Connection works for the Year 2016-17 Technical Specification for Overhead and Underground Service Connection works for the Year 2016-17
More informationLightning Conduction System Design Concepts & Components For
Lightning Conduction System Design Concepts & Components For Trees Dr. Kim D. Coder, Professor of Tree Biology & Health Care, Warnell School, UGA Trees have great value. The architectural, ecological,
More informationSECTION CHAIN LINK FENCING
SECTION 02835 - CHAIN LINK FENCING 1.0 GENERAL 1.1 Furnish and install chain link fencing complete in place with gates and accessories as specified herein and as shown on the Contract Drawings. 1.2 Reference
More informationSUPPLY ERECTION TOTAL RATE AMOUNT RATE AMOUNT AMOUNT (Rs.) (Rs.) (Rs.) (Rs.) (Rs.)
SBI-AO2 Project Residency Rd Br-elect/RBO-4 SCHEDULE OF QUANTITIES FOR ELECTRICAL WORKS. DATE : 24/4/2018 Sl. No. DESCRIPTION OF WORK UNIT QTY 1 READYMADE FINAL DISTRIBUTION BOARDS Supply, Instillation,
More informationF4P lay-in lugs SERIES SPECIFICATION
F4P lay-in lugs SERIES SPECIFICATION Lay-in lugs are ideal for both grounding and continuous loop applications. Made of aluminum alloy and tin plated for low contact resistance, they are suitable for use
More informationENGINEERING SPECIFICATION EE SPEC
/. Company Directive ENGINEERING SPECIFICATION EE SPEC : 84/1 Relating to Surge Arresters EE SPEC : 84/1 20 December 2013-1 of 7 - IMPLEMENTATION PLAN Introduction This document defines the surge arresters
More informationPractical Checklists of Best Practices Frank Donovan, W3LPL
Design, Construction and Maintenance of Antennas and Towers for Storm Survival and Long Term Reliability Practical Checklists of Best Practices Frank Donovan, W3LPL Typical A Typical Guyed Guyed Tower
More informationGLENWOOD PLACE 2 MAR 2015
PART 1 - GENERAL 1.01 SUMMARY: SECTION 16110 RACEWAYS A. Description: 1. Provide continuous conduit systems - beginning at the service point, to all distribution equipment and to every outlet and piece
More informationLIGHTNING PROTECTION SYSTEM EARTHING SYSTEM ELECTRICAL ACCESSORIES
LIGHTNING PROTECTION SYSTEM EARTHING SYSTEM ELECTRICAL ACCESSORIES AIR TERMINAL AIR TERMINAL FIXING BASE (flat) Material Aluminium / Copper Model Al-300-16 / Cu-300-16 Model Al-16 / GM-16 Diameter 16mm
More informationSECTION PART 1 GENERAL
SECTION 16060 GROUNDING AND BONDING PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Grounding of electrical systems and equipment and basic requirements for ground for equipment, circuits, and systems.
More informationEffective June, Eaton-Durham Model # UTRS223ACH. Siemens, Model # SUAS877-PG. (or Landis & Gyr # UAS877-PG) Milbank. Model # U1980-O.
Siemens, Model # SUAS877-PG (or Landis & Gyr # UAS877-PG) Eaton-Durham Model # UTRS223ACH Milbank Midwest Model # U980-O UTRS223AMEP These are some examples of the single meter sockets we require for underground
More informationEXTERNAL GROUNDING (EARTHING)
EXTERNAL GROUNDING (EARTHING) CHAPTER 4 This chapter provides requirements and guidelines for designing and installing the external grounding (earthing) electrode system at a communications site. This
More informationEARTHING & LIGHTING PROTECTION
EARTHING & LIGHTING PROTECTION RELIABLE CONNECTION SOLUTIONS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Introduction Legrand Seico, an ISO certified and approved vendor in
More informationSECTION ORNAMENTAL ALUMINUM RAILING
SECTION 05730 ORNAMENTAL ALUMINUM RAILING PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Pipe Railing 1.2 RELATED SECTIONS A. Section 03300 Cast-In-Place Concrete: Placement of sleeves cast in concrete.
More informationSECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS
SECTION 26 05 26 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationCHAPTER 13 GROUNDING AND BONDING
GROUNDING AND BONDING CHAPTER 13 GROUNDING AND BONDING Grounding and bonding must be in accordance with Article 250 of the National Electrical Code (NEC). Bonding is defined in the NEC as the permanent
More informationStack Parking Surface Mounted Stackers
1 / 6 Stack Parking Surface Mounted Stackers swiss-park V-2 Comfort The V-2 is designed to park cars of any size thanks to its vertical adjustability. It will accommodate cars as tall as the garage ceiling
More informationFacility and Equipment Grounding
Facility and Equipment Grounding - 2005 Course: PQE203 Presented by: PowerCET Corporation 3350 Scott Blvd. Bldg. 55 Unit 1 Santa Clara, CA 95054 408/988-1346 Fax 408/988-4869 E-mail: training@powercet.com
More informationTECHNICAL SPECIFICATIONS OF LAYING OF UNDER GROUND POWER CABLE FOR TRANSMISSION LINE
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS OF LAYING OF UNDER GROUND POWER CABLE FOR TRANSMISSION LINE GETCO/E/TS LUC058/R1
More informationWATER METER SPECIFICATIONS
City of Langley WATER METER SPECIFICATIONS Page i January 2010 CONTENTS SECTION TITLE PAGE 1. Preamble 1 2. Definitions 1 3. Services to be Metered 2 4. Location of Meters 2 5. Meter Types 2 6. Registers
More informationSr. No. Description Qty Unit Rate Amount. S e t
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TRANSMISSION CIRCLE OFFICE, NADIAD SCHEDULE -B Name of work : ARC for Erection of Structure, Equipments, Earthing, Termination, Laying Control Cables 66/11KV
More informationRead Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED
Chapter 17 Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.1.1 Applicability The regulations in this chapter apply to any private potable water supply system where plumbing fixtures are
More informationCONSTRUCTION SPECIFICATION FOR TRAFFIC ACTUATION EQUIPMENT
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 623 JANUARY 1990 CONSTRUCTION SPECIFICATION FOR TRAFFIC ACTUATION EQUIPMENT 623.01 SCOPE 623.02 REFERENCES 623.05 MATERIALS TABLE OF CONTENTS 623.05.01
More informationGROUNDING MATERIAL PROTECTION BY GROUNDING 3.2
GROUNDING MATERIAL PROTECTION BY GROUNDING Woertz AG Hofackerstrasse 47, P.O. Box 948, CH-4132 Muttenz 1, Switzerland Phone ++41 (0)61 466 33 33, Fax ++41 (0)61 461 96 06 www.woertz.ch Woertz USA 151 Discovery
More informationwww.eaton.eu\busbars Power Xpert XP2 Aluminium Eaton Power Xpert XP2 is a 1000 Volt totally encased, non-ventilated, low impedance sandwich construction. The range is available from 800A - 5000A with multiple
More informationNPS/001/024 Technical Specification for Low Voltage Aerial Bundled Conductor Fittings
Version:- 5.0 Date of Issue:- July 2017 Page 1 of 12 NPS/001/024 Technical Specification for Low Voltage Aerial Bundled Conductor Fittings 1. Purpose The purpose of this document is to outline the technical
More informationSECTION ALUMINUM HANDRAIL SYSTEMS
SECTION 05520 ALUMINUM HANDRAIL SYSTEMS PART 1 - GENERAL 1.01 SUMMARY A. Section includes aluminum handrails and railings. B. Related Work: 1. Section 03300 - Cast-in-Place Concrete C. References: 1. American
More informationTHATCH STRUCTURES LIGHTNING PROTECTION INNOVATION ISOLATED LIGHTNING PROTECTION USING HVI CONDUCT
THATCH STRUCTURES LIGHTNING PROTECTION INNOVATION ISOLATED LIGHTNING PROTECTION USING HVI CONDUCTORS PREPARED BY : LIGHTNING PROTECTION CONCEPTS PONTINS REFERENCE : D001-THATCH-051 ISSUE : A DATE : 4 March
More informationOntario ENGINEERING STANDARD SPECIFICATION 1/10 REV. ELECTRICAL DISTRIBUTION HIGH VOLTAGE SUBSTATION GROUNDING AND BONDING. Approved by.
/0 Rev Description Revision by Approved by Issue Date YYYY/MM/DD New Format Replaces 5322-0.0. T.C. 206/02/09 T.C. 206/03/02 206/03/02 2/0.0 PURPOSE This specification describes the minimum requirements
More informationA. The work consists of furnishing a Chiller Noise Reduction System as listed in the specifications.
SECTION 32 31 14 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply
More informationSPECIAL REPAIRS TO EXTERNAL SANITARY ARRANGMENTS AND STREET LIGHTS IN ESI DISPENSARY I & II CAMPUS AT PERAMBUR
SPECIAL REPAIRS TO EXTERNAL SANITARY ARRANGMENTS AND STREET LIGHTS IN ESI DISPENSARY I & II CAMPUS AT PERAMBUR FINANCIAL BID Item DSR Item Description Qty Units No No. Total 1.1.1 Excavating trenches of
More informationSECTION 2831 ITEM F-162 CHAIN-LINK FENCES
SECTION 2831 ITEM F-162 CHAIN-LINK FENCES PART 1 - GENERAL 1.1 DESCRIPTION. This item shall consist of furnishing and erecting a chain-link fence in accordance with these specifications and the details
More informationIET Wiring Regulations (BS 7671:2008+A3:2015) - SECTION 705 AGRICULTURAL AND HORTICULTURAL PREMISES
IET Wiring Regulations (BS 7671:2008+A3:2015) - SECTION 705 AGRICULTURAL AND HORTICULTURAL PREMISES 705.1 Scope The particular requirements of this section apply to fixed electrical installations indoors
More information