OPTISENS TUR Quick Guide. The documentation is only complete when used in combination with the relevant documentation for the signal converter.

Size: px
Start display at page:

Download "OPTISENS TUR Quick Guide. The documentation is only complete when used in combination with the relevant documentation for the signal converter."

Transcription

1 OPTISENS TUR 2000 Quick Guide The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE 08/2012 TD OPTISENS TUR 2000 R01 en

2 Turbidity sensor for water and waste water application Turbidity measurement is widely used in drinking water and wastewater applications. Therefore the turbidity measurement will be used for filter monitoring and quality control of water in waste water plants. The turbidity sensor OPTISENS TUR 2000 from KROHNE has a standardized robust design for open channel measurement and a long lifespan. Therefore the sensor is especially designed for small and medium-sized wastewater treatment plants. The integrated spray cleaning system minimizes the need for manual cleaning, which means longer intervals between maintenance and calibration. Highlights OPTISENS TUR 2000 Precise turbidity measurement <40 FNU/NTU through the 90 scattered light method Measurement according to ISO 7027/US EPA Short response time for all application Long-term stability due to reduced clogging by integrated spray cleaning system Low cost of ownership Suitable for installation with telescopic rod SENSOFIT IMM 2000 Industry Waste water industry Applications SENSOFIT IMM 2000 Water quality control in the outlet Filter monitoring

3 1. Dimension (1) Attached cable (2) Air input (3) Thread (4) Air nozzle (5) Sensing element

4 2. Electrical Connections Safety instructions DANGER! All work done on the electrical connections may only be carrier out with the power disconnected. Take note of the voltage data on the nameplate! DANGER! Observe the national regulations for electrical installations! WARNING! Observe without fail the local occupational health and safety regulations. Any work done on the electrical components of the measuring device may only be carried out by properly trained specialists. INFORMATION! Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. Connecting sensor cable to signal converter J Q Y V W Sensor connection terminals MAC 100 (1) Sensor connection terminals (2) Terminal block S (protective earth) (3) Terminal block A: terminals for sensor and temperature

5 INFORMATION! For OPTISENS TUR 2000 there is only the single channel version is available and the interface "Pos.A" is populated. INFORMATION! Connecting the sensor cable to the MAC 100 signal converter Thread the sensor cable through the cable gland (1). To connect the cable to the signal converter, press down the wire (7) on the corresponding terminal. To remove a cable, press down the white clip (8) on the corresponding terminal and pull the cable out. Wire J Q Y V W Terminal block A White Green Yellow Grey Not connected

6 3. Power supply Open the cover of the electrical terminal compartment by pressing down and pulling forwards at the same time. 1. Figure 1: Power supply connection (1) VAC (-15%/+10%), 8 VA (3) 24 VAC/DC (AC: -15%/+10%; DC: -25%/+30%) Close the cover after the power has been connected. 24 VAC/DC (tolerance range: AC: -15% / +10%; DC: -25% / +30%) AC: Note the power supply voltage and frequency (50 60 Hz) on the nameplate. DC: When connecting to functional extra-low voltages, provide a facility for protective separation (PELV) (acc. To VDE 0100 / VDE 0106 and IEC 364 / IEC 536 or relevant national regulations). INFORMATION 12 V is not included in the tolerance range.

7 4. Calibration INFORMATION! The calibration of OPTISENS TUR 2000 is a 2-point calibration. The calibration of the zero standard value (zero point) takes place in distilled water. Please consider that the given value of the zero standard should not deviate more than ±0.400 NTU from the measured value. The calibration of the sensitivity takes place in a media with defined turbidity value. As an alternative also formazine can be used. The deviation should not be more than ±30 % of the measuring range. 1. Calibration of the zero standard value Press > for 2,5 sec., then release the button. You are now on the main menu level. You are on the main menu level. In the upper line on the right side of the display "A" appears, beneath the main menu quick setup is highlighted. Press the or until the main menu setup is highlighted. Main menu A quick Setup B test > C setup D service Press > to enter the chosen menu. The submenu process input A is highlighted. Press > to enter the chosen menu. Press or until the menu product cal. is highlighted. Press > to enter the chosen menu. On the display the actual turbidity value is highlighted. Please wait till the value is stabel and then press to start the calibration. Press or to set the zero standard value in NTU. Press to confirm the entered value. The menue Start calib. is highlighted. Start the calibration with the zero standard value and press.

8 The message zero point calibration successful is highlighted if the calibration was successful. In this case press and proceed with the calibration of the sensitivity standard value. The message zero point calibration unsuccessful is highlighted if the calibration has failed. Press and answer the question to repeat the calibration with yes or no. Press or and confirm with. 2. Calibration of the sensitivity standard value If the zero standard value calibration was successful press to start the calibration of the sensitivity. On the display the actual turbidity value is highlighted. Wait till the value is stable and then press to start the calibration. Press or to set the sensitivity standard value in NTU. Press to confirm the entered value. The menu start calib. is highlighted. Press to Start the calibration for the sensitivity standard value. The message calibration sensitivity standard value successful is highlighted, if the calibration was successful. In this case press several times to leave the calibration menu. The message calibration sensitivity standard value unsuccessful is highlighted if hte calibration has failed. Press and answer the question to repeat the calibration with yes or no. Press or and confirm with.

9 5. Technical data Parameter Measuring principle Type Electrode Measuring range 90 stray light sensor for turbidity measurements with NIR-LED for long-term stability and automatic cleaning OPTISENS TUR 2000 Turbidity 90 straylight Digital sensor with 4 20 ma current output for connection to MAC 100 Near Infrared (NIR) - LED NTU/FNU NTU/FNU NTU/FNU measuring range is preconfigured at KROHNE (40 NTU is standard) Accuracy < 1 % or Process temperature Process pressure Installation conditions Materials C/ F 1 bar; 14.5 psi Immersion installation PVC Enclosure rating IP 68 Cleaning system Connector Cables Others Integrated cleaning nozzle for compressed air core ends 10 m/33 ft. attached cable Integrated temperature sensor

10 6. Order Code Order Code OPTISENS TUR 2000 Sensors and cable - Turbidity VGAW 4 Sensor type A* OPTISENS TUR 2000 Measuring Range NTU/FNU 2* NTU/FNU NTU/FNU Sensor Features A* 1x 4..20mA/RS485 Process conditions 1* C/ F Enclosure type B* Submersible w ith flush nozzle Body material 1* PVC Process connection A* Submersible; 2"NPT threat for mounting Pow er supply 1* VDC/loop pow ered cable B* cable TUR-W 2000 cable Features A* Attached cable cable length 3* 10 m (33 ft.) cable Options 1* core sleeves ends Sensor Options 1* Flush nozzel plus 10 m/33ft. flush hose Documentation 0 none 1* English 2 German (available from Q2 2012) 3 French (available from Q2 2012) 4 Spanish (available from Q2 2012) VGAW 4 Order code

Calibration and Standards. AMCO Standards for use in Drinking Water Analysis

Calibration and Standards. AMCO Standards for use in Drinking Water Analysis Quality Control using Measurements measurements are of extreme importance in quality monitoring in water, wastewater, beverage production, electroplating and petrochemical applications. Typical turbidity

More information

Technical Information Turbimax CUS52D

Technical Information Turbimax CUS52D TI01136C/07/EN/01.13 71237018 Products Solutions Services Technical Information Turbimax CUS52D Turbidity sensor Installation and immersion sensor for low to medium turbidity Application Turbimax CUS52D

More information

Drinking Water Monitoring. Ready-to-use systems for monitoring of quality relevant parameters in

Drinking Water Monitoring. Ready-to-use systems for monitoring of quality relevant parameters in Drinking Water Monitoring Ready-to-use systems for monitoring of quality relevant parameters in drinking water Single-parameter - Systems Single-parameter Systems Single-parameter systems for measurement

More information

Vibranivo Mononivo. Series VN 4000 MN Series. Instruction manual

Vibranivo Mononivo. Series VN 4000 MN Series. Instruction manual Vibranivo Mononivo Series Series VN 4000 MN 4000 Instruction manual 010516 1 UWT GmbH Westendstraße 5 Tel.: +49 (0)831 57123-0 Internet:www.uwt.de D-87488 Betzigau Fax: +49 (0)831 76879 E-Mail: info@uwt.de

More information

RANGE DIGISENS PHEHT:PH, REDOX & TEMPERATURE

RANGE DIGISENS PHEHT:PH, REDOX & TEMPERATURE RANGE DIGISENS PHEHT:PH, REDOX & TEMPERATURE Digital Technology for optimized measures Combination ph/redox/temp sensor Digital Sensor : Modbus RS 485 / SDI-12 Calibration data inside ph/orp Cartridge

More information

INSULATION MONITORING RELAIS

INSULATION MONITORING RELAIS October 2010 RELAIS industrial applications for use in medical rooms e l e t t ro n i c a www.contrel.it HRI series GENERAL Devices allow insulation monitoring for IT systems in medical use rooms, as well

More information

Turbimax CUE25 / CUE26

Turbimax CUE25 / CUE26 Technical Information Turbimax CUE25 / CUE26 Handheld turbidimeter for field measurement Application Turbimax CUE25 / CUE26 are compact handheld meters for the measurement of turbidity in the field. They

More information

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4 SENSORS FOR FOOD AND BIOPHARMA. Product Information ITM-4 FOOD 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring

More information

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4 SENSORS FOR AND BIOPHARMA. Product Information ITM-4 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring Phase

More information

RANGE DIGISENS PHEHT : PH, REDOX & TEMPERATURE

RANGE DIGISENS PHEHT : PH, REDOX & TEMPERATURE RANGE DIGISENS PHEHT : PH, REDOX & TEMPERATURE Digital Technology for optimized measures Combination ph/redox/temp sensor Digital Sensor : Modbus RS 485 / SDI-12 Calibration data inside ph/orp Cartridge

More information

Series 5000 Analyzers Low Range Phosphate Model and High Range Phosphate Model 60001

Series 5000 Analyzers Low Range Phosphate Model and High Range Phosphate Model 60001 Series 5000 Analyzers Low Range Phosphate Model 60005 and High Range Phosphate Model 60001 D epending upon your analysis needs, you can choose from two continuous-reading process analyzers to measure phosphate.

More information

POWER FACTOR REGULATOR. Computer-12e-xx INSTRUCTION MANUAL ( M / 02A ) (c) CIRCUTOR S.A.

POWER FACTOR REGULATOR. Computer-12e-xx INSTRUCTION MANUAL ( M / 02A ) (c) CIRCUTOR S.A. POWER FACTOR REGULATOR Computer-12e-xx INSTRUCTION MANUAL ( M 981 606 / 02A ) (c) CIRCUTOR S.A. -------- POWER FACTOR REGULATOR COMPUTER- 12e --------- Page 2 POWER FACTOR REGULATOR COMPUTER- 12e 1.- POWER

More information

Analyze IT Single and Dual Input Dissolved Organics Monitor

Analyze IT Single and Dual Input Dissolved Organics Monitor Data Sheet Analyze IT Single and Dual Input Dissolved Organics Monitor Dual input enables two measurements from one instrument, each input can be either high range or low range cost effective Surrogate

More information

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4 1 Product Information ITM-4 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Authorizations Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring Phase separation

More information

Q u a l i t y C o n t r o l U s i n g Tu r b i d i t y Measurements

Q u a l i t y C o n t r o l U s i n g Tu r b i d i t y Measurements Turbidity Measurements Q u a l i t y C o n t r o l U s i n g Tu r b i d i t y Measurements Turbidity measurements are of extreme importance in quality monitoring in water, wastewater, beverage production,

More information

4690 Series Turbidity systems. Accurate, reliable turbidity measurement

4690 Series Turbidity systems. Accurate, reliable turbidity measurement Data sheet DS/4690 EN Rev. B 4690 Series Turbidity systems Accurate, reliable turbidity measurement Flow-through turbidity design Fast response to process turbidity changes due to minimal sample residence

More information

PD662 LOOP-POWERED METER

PD662 LOOP-POWERED METER PD662 LOOP-POWERED METER 4-20 ma Input Loop-Powered -1999 to 2999 Display Easy Four-Button Programming NEMA 4X Enclosure Programmable Noise Filter Loop-Powered Backlight Option 1.7 Volt Drop without Backlight

More information

Triton TR8 Turbidity Analyzer

Triton TR8 Turbidity Analyzer Triton TR8 Turbidity Analyzer The Clear Choice Water to Sludge ELECTRO-CHEMICAL DEVICES What is Turbidity? Standard Methods for the Examination of Water and Wastewater describes Turbidity as an expression

More information

FIXED-WINDOW POWER DEMAND CONTROLLER BY ENERGY PULSES CVM-R8D-CPP INSTRUCTION MANUAL

FIXED-WINDOW POWER DEMAND CONTROLLER BY ENERGY PULSES CVM-R8D-CPP INSTRUCTION MANUAL FIXED-WINDOW POWER DEMAND CONTROLLER BY ENERGY PULSES CVM-R8D-CPP INSTRUCTION MANUAL ( M 981 316 / 99B ) (c) CIRCUTOR S.A. ------ Power demand controller by energy pulses - CVM-R8D-CPP ---------- Page

More information

PD662 LOOP-POWERED METER Instruction Manual

PD662 LOOP-POWERED METER Instruction Manual PD662 LOOP-POWERED METER C US 4-20 ma Input Loop-Powered -1999 to 2999 Display Easy Four-Button Programming NEMA 4X Enclosure Programmable Noise Filter Loop-Powered Backlight Option 1.7 Volt Drop without

More information

Zirconia Oxygen Analyzer

Zirconia Oxygen Analyzer Data Sheet SS/ZDT/GP_6. Zirconia Oxygen Analyzer High Temperature Version ZDT GP Series Cost-effective solution for high temperature applications NEMA 4X/IP66 protection reliable operation in demanding

More information

UV300 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

UV300 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE- ON LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, 38240 MEYLAN -FRANCE- TEL : +33 4 76 41 86 39 - FAX : +33 4 76 41 92 27 MAIL : SALES@TETHYS-INSTRUMENTS.COM - WEB : WWW.TETHYS-INSTRUMENTS.COM

More information

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring Level Measurement and Monitoring FN04 Liquid level sensor with continuous detection Level measurement unaffected by foam formation, conductivity, pressure or temperature Remote indication over very long

More information

Turbimax CUS51D. Technical Information

Turbimax CUS51D. Technical Information Technical Information Turbimax CUS5D Sensor for turbidity and solids content Installation and immersion sensor for low, middle and high turbidity and solids concentrations Application Turbimax CUS5D is

More information

Tintometer -Group. MicroDirect (IP 67 waterproof) Optional temperature measurement Celsius/ Fahrenheit

Tintometer -Group. MicroDirect (IP 67 waterproof) Optional temperature measurement Celsius/ Fahrenheit Tintometer -Group MicroDirect (IP 67 waterproof) Optional temperature measurement Celsius/ Fahrenheit ph ORP/Redox Conductivity TDS Salinity Temperature 110 Regularly updated information: www.tintometer.com

More information

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A. FAST POWER FACTOR REGULATOR Computer-14df - xx - 144a INSTRUCTION MANUAL ( M 981 611 / 00A ) (c) CIRCUTOR S.A. -------- POWER FACTOR REGULATOR COMPUTER- 14f --------- Page 2 POWER FACTOR REGULATOR COMPUTER-

More information

INSULATION GUARD MEG (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

INSULATION GUARD MEG (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A. INSULATION GUARD MEG-1000 (Code 2 28 981) INSTRUCTION MANUAL ( M 981 220 / 99A ) (c) CIRCUTOR S.A. ----- Insulation guard MEG-1000 -------- M - 981 220 --- Page nº 1 Insulation guard MEG-1000 1.- BASIC

More information

Differential pressure measuring instrument

Differential pressure measuring instrument Differential pressure measuring instrument testo 521 Precise Pitot tube measurement Temperature-compensated differential pressure sensor in instrument Additional 2 probe inputs for the connection of further

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Supplementary electronics for 4-wire connection Structural design Dimensions (W x H x D) in mm (inch) Electrical connection 80x10x60 (3.15x4.7x.36) Screw terminals (Pg 13.5 cable inlet) or Han

More information

SPECIFICATION SHEET FLUORIDE ION MONITOR SYSTEM CONFIGURATION. Model: FBM Fluoride Ion Monitor - Issue: FBM R1 Page 1

SPECIFICATION SHEET FLUORIDE ION MONITOR SYSTEM CONFIGURATION. Model: FBM Fluoride Ion Monitor - Issue: FBM R1 Page 1 ISO-14001 ISO-9001 SPECIFICATION SHEET FLUORIDE ION MONITOR Model: FBM-300 The Model FBM-300 provides fast and continuous detection of free fluoride ion concentration in water. It is widely used for monitoring

More information

Lovibond Water Testing Tintometer Group

Lovibond Water Testing Tintometer Group Lovibond Water Testing Tintometer Group Process Turbidimeters & Accessories PTV Series Smart Interface - Rethink the Controller Simplified and Streamlined Processes Innovative, Low Maintenance Design Unsurpassed

More information

ENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument

ENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument Datasheet ENGLISH Platinum Resistance Thermometer Pt100 Outdoor/Cold Store Temperature Sensors IP67 Weatherproof Housing, 4 wire single or dual element, or 4-20mA option Weatherproof IP67 rated wall mounting

More information

Galaxy 300. Operation 05/

Galaxy 300. Operation 05/ Galaxy 300 60 80 kva Operation 05/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred to in this guide

More information

Expert SUBMERSIBLE LEVEL TRANSMÍTTERS BROCHURE US 2.75 EXPERT BROCHURE 1401

Expert SUBMERSIBLE LEVEL TRANSMÍTTERS BROCHURE US 2.75 EXPERT BROCHURE 1401 Expert SUBMERSIBLE LEVEL TRANSMÍTTERS BROCHURE US 2.75 EXPERT BROCHURE 1401 OUTSTANDING DURABILIT Y AND HIGH PRECISION 2 MJK level transmitters are designed for level measurement by immersion in open channels,

More information

TB100 Portable Turbidity Meter Instruction Manual

TB100 Portable Turbidity Meter Instruction Manual TB100 Portable Turbidity Meter Instruction Manual BANTE INSTRUMENTS CO., LTD TB100 Portable Turbidity Meter 1 Introduction Thank you for selecting the TB100 portable turbidity meter. This manual provides

More information

Turbimax CUE25 / CUE26

Turbimax CUE25 / CUE26 Technical Information Turbimax CUE25 / CUE26 Handheld turbidity meter for field measurement Application Turbimax CUE25 / CUE26 are compact handheld meters for the measurement of turbidity in the field.

More information

The New Turb 430 T according to US EPA

The New Turb 430 T according to US EPA The New Turb 430 T according to US EPA Turb 430 T is the new portable turbidimeter with tungsten lamp for the measuring range from 0 1100 NTU according to US EPA 180.1. It covers the measurement range

More information

VAC measuring instrument

VAC measuring instrument Data sheet VAC measuring instrument The service instrument for ventilation and air conditioning systems Point and timed mean value calculation Direct display of the volume flow Automatic allocation of

More information

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features EE300ExHT The EE300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone

More information

HOBO Plug Load Logger (UX ) Manual

HOBO Plug Load Logger (UX ) Manual HOBO Plug Load Logger (UX120-018) Manual The HOBO Plug Load logger is designed to monitor energy consumption of AC-powered plug in loads. This compact device can be used as a power meter with its built-in

More information

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features EE300ExHT The EE300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. AW400 Residual chlorine monitor

ABB MEASUREMENT & ANALYTICS DATA SHEET. AW400 Residual chlorine monitor ABB MEASUREMENT & ANALYTICS DATA SHEET AW400 Residual chlorine monitor 2 AW 400 RESI DUAL CH LORI N E MO NITOR DS/AW400-E N RE V. F Measurement made easy For the measurement of free and total residual

More information

EPA Compliant Turbidity & Chlorine Meter

EPA Compliant Turbidity & Chlorine Meter EPA Compliant Turbidity & Chlorine Meter New Turbidity Technology from HANNA HANNA s new HI 98703 and HI 93414 utilize an EPA compliant tungsten light source and state-of-the-art optical system that allow

More information

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter HI 98703 EPA Compliant Turbidity Meter HI 93414 EPA Compliant Turbidity and Chlorine Meter SPECIFICATIONS Turbidity (HI 93414 & HI 98703) Range Range Selection ACCESSORIES HI 710005 Voltage adapter HI

More information

1 analogue output. 4Programmable for measurement. 4 The limits of the outputs are freely programmable within the measuring range.

1 analogue output. 4Programmable for measurement. 4 The limits of the outputs are freely programmable within the measuring range. 35 series The 35 series developed by Chemitec is dedicated to the water treatment and industry sectors, and enables the following parameters to be measured: Process control device 4pH/REDOX 4Dissolved

More information

Pressure transducers DMU 02 Vario (flush)

Pressure transducers DMU 02 Vario (flush) Process engineering (flush) Ideal for hygienic processes Connection technology with numerous versions Extremely resistant to shock, pulsation and vibration Best dynamic pressure resistance at high load

More information

Online data sheet MCS100E HW-C CEMS SOLUTIONS

Online data sheet MCS100E HW-C CEMS SOLUTIONS Online data sheet MCS100E HW-C A B C D E F H I J K L M N O P Q R S T Ordering information Type MCS100E HW-C Part no. On request The exact device specifications and performance data of the product may deviate

More information

Besides measurement of humidity and temperature EE30EX series calculate the values of the following physical quantities:

Besides measurement of humidity and temperature EE30EX series calculate the values of the following physical quantities: Series 0EX series transmitters from Automatikprodukter are designed for the accurate measurement of humidity and temperature in the range between 0...0% RH and -40...180 C (-40... ). Models for pressure

More information

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua Dr. Oliveira Salazar, nº 88 4780-453 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 809 124 Fax. +351 252 859 298

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. AV410, AV411, AV420, AV412 and AV422 Single and dual input dissolved organics monitor

ABB MEASUREMENT & ANALYTICS DATA SHEET. AV410, AV411, AV420, AV412 and AV422 Single and dual input dissolved organics monitor ABB MEASUREMENT & ANALYTICS DATA SHEET AV410, AV411, AV420, AV412 and AV422 Single and dual input dissolved organics monitor 2 AV 410, AV 411, AV 4 20, AV 41 2 AN D AV4 2 2 DISSOLV E D ORGANIC S MONITOR

More information

HLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

HLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features HLX300ExHT The HLX300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone

More information

PDO2 Precision Dissolved Oxygen Measurement

PDO2 Precision Dissolved Oxygen Measurement PDO2 Precision Dissolved Oxygen Measurement For Municipal and Industrial Waste Water Treatment Fluorescent Dissolved Oxygen Monitoring System Designed for use in the Harshest Environments Barben Analyzer

More information

HRI-R22t series GENERAL FUNCTIONS AND OPERATORS - LEGENDA INSULATION MONITORING VERSIONS FOR USE IN MEDICAL ROOMS

HRI-R22t series GENERAL FUNCTIONS AND OPERATORS - LEGENDA INSULATION MONITORING VERSIONS FOR USE IN MEDICAL ROOMS HRI-R22t series GENERAL HRI-R22t series The device has similar characteristics of previous model but it s more cheap and it has less functions. There is measuring signalling and it is able to verify temperature

More information

online measurement electrodes

online measurement electrodes online measurement electrodes ph Conductivity ORP Turbidity Optical Dissolved Oxygen Dissolved Ozone Dissolved Oxygen Free Chlorine For three decades HF scientific has developed specialized expertise in

More information

Turbimax CUE25 / CUE26

Turbimax CUE25 / CUE26 Technical Information Turbimax CUE25 / CUE26 Handheld turbidity meter for field measurement Application Turbimax CUE25 / CUE26 are compact handheld meters for the measurement of turbidity in the field.

More information

PD662 Loop-Powered Meter Instruction Manual

PD662 Loop-Powered Meter Instruction Manual PD662 Loop-Powered Meter C US 4-20 ma Input Loop-Powered -1999 to 2999 Display Easy Four-Button Programming NEMA 4X Enclosure Loop-Powered Backlight Option 1.7 Volt Drop without Backlight 32-Point and

More information

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or

More information

Carbon Dioxide Controller

Carbon Dioxide Controller User Guide Carbon Dioxide Controller Horticultural Carbon Dioxide GAS FLOW RATE O.17 lpm H Introduction Thank you for purchasing the Ecotechnics Carbon Dioxide Controller. In order to take full advantage

More information

Total Suspended Solids Systems

Total Suspended Solids Systems Total Suspended Solids Systems Model 711 Portable MLSS/ILA System Applications Model 711 Remote monitoring Environmental / Conservation Aeration basin monitoring Education / Classroom studies Clarifier

More information

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email:

More information

Model PD656 Large Display Process Meter with Rate/Totalizer/Batch Control Features Instruction Manual

Model PD656 Large Display Process Meter with Rate/Totalizer/Batch Control Features Instruction Manual with Rate/Totalizer/Batch Control Features Easy Single Button Scaling (SBS) 4-20 ma, 1-5 V, 0-5 V, or 0-10 V Field Selectable Inputs Large 0.8" (20.3 mm) High LEDs Full Six Digit Display for Total, 4½

More information

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass flow, volume flow, temperature and density and consequently can replace different

More information

Model SUP-PH4.0/PH6.0. Supmea SUP-PH4.0 Supmea SUP-PH6.0. Features SUP-PH4.0

Model SUP-PH4.0/PH6.0. Supmea SUP-PH4.0 Supmea SUP-PH6.0. Features SUP-PH4.0 Supmea SUP-PH4.0 Supmea SUP-PH6.0 The SPE-PH200 is a true multivariable analyzer used for measuring/controlling the ph with temperature and ORP. The function is switchable on the device itself. Depending

More information

ENGLISH Datasheet JIS Miniature Thermocouple Connector Panel Fascia Sockets Types K, J, T, E, R/S & B (JIS Colour Code)

ENGLISH Datasheet JIS Miniature Thermocouple Connector Panel Fascia Sockets Types K, J, T, E, R/S & B (JIS Colour Code) ENGLISH Datasheet JIS Miniature Thermocouple Connector Panel Fascia Sockets Types K, J, T, E, R/S & B (JIS Colour Code) Miniature thermocouple fascia mounting sockets with clip All fascia mounting sockets

More information

Intelligent SUNTEX PC-3310 ph/orp Transmitter

Intelligent SUNTEX PC-3310 ph/orp Transmitter ph ORP C Intelligent SUNTEX PC-3310 ph/orp Transmitter Intelligent ph/orp Transmitter PC-3310 High quality, high performance, high safety Intuitive menu driven operation Extremely protection ability PC-3110,

More information

3 PHASE ENERGY ELECTRONIC METERS MKB-363-M INSTRUCTION MANUAL ( M / 00 B

3 PHASE ENERGY ELECTRONIC METERS MKB-363-M INSTRUCTION MANUAL ( M / 00 B 3 PHASE ENERGY ELECTRONIC METERS MKB-363-M INSTRUCTION MANUAL ( M 981 198 / 00 B ) (c) CIRCUTOR S.A. -- MKB-363-M ELECTRONIC METERS -- M-981198 -- Page Nº 2 THREE-PHASE THREE-WIRE ACTIVE ENERGY ELECTRONIC

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Output

More information

VAC measuring instrument

VAC measuring instrument VAC measuring instrument testo 445 The service instrument for ventilation and air conditioning systems Point and timed mean value calculation C Direct display of the volume flow Automatic allocation of

More information

VAC measuring instrument

VAC measuring instrument VAC measuring instrument testo 445 The service instrument for ventilation and air conditioing systems Point and timed mean value calculation C Direct display of the volume flow Automatic allocation of

More information

Model Product Description and Specifications

Model Product Description and Specifications Model 900403 Product Description and Specifications Winner of PTEN Innovation Award The Model 900403 Handheld All 4 Gases in a 5 Lb Battery Powered Gas Analyzer! Full-featured gas analyzer that you can

More information

MICROSTAT-M. Page 1/7. Data Sheet Type /2160. Type / /

MICROSTAT-M. Page 1/7. Data Sheet Type /2160. Type / / 3639 Fulda, Germany Postal address: 3635 Fulda, Germany Phone: +49 661 63- Fax: +49 661 63-67 Harlow - Essex CM2 2DY, UK Data Sheet 6851 Page 1/7 MICROSTAT-M Particularities Electromechanical temperature

More information

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200 ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200 The GRD 4200 is an electronic earthing equipment for tankers during loading and unloading operations of flammable liquids in places with danger of explosion.

More information

ProODO Optical Dissolved Oxygen Meter for the Lab or Field SPECIFICATIONS

ProODO Optical Dissolved Oxygen Meter for the Lab or Field SPECIFICATIONS ProODO Optical Dissolved Oxygen Meter for the Lab or Field SPECIFICATIONS ProODO Digital Optical Dissolved Oxygen Meter YSI ODO technology reduces the time required to calibrate and maintain your sensors.

More information

Q & A on Moisture in Transformer Oil

Q & A on Moisture in Transformer Oil Q & A on Moisture in Transformer Oil A unique opportunity to answer your specific questions about Moisture in Transformer Oil Behavior Steven Jiroutek Business Development Manager - Industrial Measurements

More information

Data sheet HYGROPHIL H 4230 process hygrometer

Data sheet HYGROPHIL H 4230 process hygrometer Data sheet HYGROPHIL H 4230 process hygrometer Continuous humidity measurement in industrial processes. HYGROPHIL H For very high demands in terms of being resistant to corrosion and dirt. Particularly

More information

This Specification Data Sheet brought to you by: Trinity Blvd. Fort Worth, Texas /

This Specification Data Sheet brought to you by: Trinity Blvd. Fort Worth, Texas / This Specification Data Sheet brought to you by: 15825 Trinity Blvd. Fort Worth, Texas 76155 817/465-9494 equipment@technicaldiagnostic.com www.technicaldiagnostic.com www.test-equipment-rental.com The

More information

200CR Two-Channel Conductivity/Resistivity Measurement System THORNTON. Leading Pure Water Analytics

200CR Two-Channel Conductivity/Resistivity Measurement System THORNTON. Leading Pure Water Analytics THORNTON Leading Pure Water Analytics - Two channels of conductivity/resistivity - Calibration with NIST traceability - Accurate three-wire temperature measurement 200CR Two-Channel Conductivity/Resistivity

More information

Model Product Description and Specifications

Model Product Description and Specifications Model 900503 Product Description and Specifications Winner of PTEN Innovation Award The Model 900503 Handheld 5 Gases in a 5 Lb Battery Powered Gas Analyzer! Full-featured gas analyzer that you can hold

More information

Introduction Bench Meters Portable Meters TURBIDITY

Introduction Bench Meters Portable Meters TURBIDITY S E C T I O N 12 C O N T E N T S N A V I G A T I O N Introduction....................12.2 Bench Meters...................12.4 Portable Meters................12.9 www.hannainst.com 12.1 12 HI 93414 Turbidity

More information

UV400 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

UV400 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE- ON LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, 38240 MEYLAN -FRANCE- TEL : +33 4 76 41 86 39 - FAX : +33 4 76 41 92 27 MAIL : SALES@TETHYS-INSTRUMENTS.COM - WEB : WWW.TETHYS-INSTRUMENTS.COM

More information

INSULATION MONITORING RELAIS

INSULATION MONITORING RELAIS October 2010 RELAIS industrial applications for use in medical rooms e l e t t ro n i c a www..it RI se rie s The RI isolation monitor series, are designed to permanently monitor the isolation to earth,

More information

Operator Manual. OHAUS Aviator 7000

Operator Manual. OHAUS Aviator 7000 Operator Manual OHAUS Aviator 7000 2 OHAUS Operator Manual Aviator 7000 Order number 72246392 Contents 1 Your new retail scale 5 1.1 Most important functions 5 1.2 Device overview 5 1.3 Safety instructions

More information

Introduction. Equipment Required. Procedure A. Blank Measurement. Cyclops In Vivo Chlorophyll Calibration Procedure

Introduction. Equipment Required. Procedure A. Blank Measurement. Cyclops In Vivo Chlorophyll Calibration Procedure Introduction Cyclops sensors provide an analog output voltage proportional to the sample concentration being measured. This procedure describes how to calibrate Cyclops sensors to approximate chlorophyll

More information

Omnicomm LLS 4 Fuel Level Sensors

Omnicomm LLS 4 Fuel Level Sensors Omnicomm LLS 4 Fuel Level Sensors User Manual 23.03.2018 Contents 3 4 5 5 7 General Specifications Preparation Fuel Tank Preparation Sensor Preparation 8 10 11 Setting Empty/Full Calibration Omnicomm LLS

More information

SABRE T MODEL PD743 TEMPERATURE METER Instruction Manual

SABRE T MODEL PD743 TEMPERATURE METER Instruction Manual SABRE T MODEL PD743 TEMPERATURE METER J, K, T, E Thermocouple & 100 Ω Pt RTD Pre-Calibrated for All Input Types Type 4X, NEMA 4X, IP65 Front Shallow Depth Case 3.2" Behind Panel 4 Digit Display, 0.56"

More information

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIA-G, DIS-G. Gas warning systems for Cl2, ClO2, O3, NH3, HCl

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIA-G, DIS-G. Gas warning systems for Cl2, ClO2, O3, NH3, HCl GRUNDFOS ALLDOS DATA BOOKLET Gas warning systems for Cl2, ClO2, O3, NH3, HCl Contents Product features Conex DIA-G gas warning systems 3 Conex DIS-G gas warning systems 3 Identification Type key, gas warning

More information

INSTRUCTION MANUAL FOR WIRE WELDING MACHINE

INSTRUCTION MANUAL FOR WIRE WELDING MACHINE INSTRUCTION MANUAL FOR WIRE WELDING MACHINE IMPORTANT: BEFORE STARTING THE EQUIPMENT, READ THE CONTENTS OF THIS MANUAL, WHICH MUST BE STORED IN A PLACE FAMILIAR TO ALL USERS FOR THE ENTIRE OPERATIVE LIFE-SPAN

More information

Sabre P Model PD603 Process Meter Instruction Manual

Sabre P Model PD603 Process Meter Instruction Manual Sabre P Model PD603 Process Meter 0-20, 4-20 ma, 0-5, 1-5, 0-10, ±10 V Inputs Type 4X, NEMA 4X, IP65 Front Shallow Depth Case 3.6" Behind Panel 4 Digit Display, 0.56" (14 mm) High, Red LEDs Easy Front

More information

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS Portable Industrial Chilled Mirror Hygrometer Fundamental drift free humidity measurement Integral frost/dew point measuring head Internal sample pump Optimal Response Injection System for fast measurement

More information

Technical Information Memosens CPS31D and Ceratex CPS31

Technical Information Memosens CPS31D and Ceratex CPS31 TI00030C/07/EN/13.13 71201979 Products Solutions Services Technical Information Memosens CPS31D and Ceratex CPS31 ph electrodes, analog and digital with Memosens technology For drinking water and swimming

More information

HotSwap MBP Maintenance Bypass

HotSwap MBP Maintenance Bypass ENGLISH HotSwap MBP Maintenance Bypass MBP6K208 MBPK208 Installation and user manual Copyright 202 EATON All rights reserved. Service and suort: Call your local service representative SAFETY INSTRUCTIONS

More information

GAA330-M Emission monitoring system for marine applications

GAA330-M Emission monitoring system for marine applications Data sheet DS/GAA330--EN Rev. A GAA330- Emission monitoring system for marine applications easurement made easy We are on your wavelength Continuous measurement of SO2, CO2 and NOx (option) with a single

More information