DML-Series. Pelton wheel flow meter
|
|
- Magnus Carpenter
- 6 years ago
- Views:
Transcription
1 DML-Series Pelton wheel flow meter
2 Flow meter manufacture As a specialist in flow measurement technology, TrigasDM supplies high-quality measuring instruments, electronics and calibrators for liquids and gases. Made in Germany Our products are exclusively developed and manufactured in Neufahrn, 20 km north of Munich, ensuring world-class technical knowhow for our customers. Contact We are proud of our high-quality products and friendly customer service and welcome you as a valued customer to our growing family. You can benefit from our long-standing experience and our comprehensive technical support. TrigasDM GmbH Tel.: Erdinger Str. 2b Fax: info@trigasdm.com Neufahrn, Germany TrigasDM GmbH - June
3 Technical data Flow range: Response time: see "Measuring ranges" table <4 ms Temperature range: -50 C to +150 C Operating pressure: Viscosity: up to 400 bar, Depending on connection, optionally also higher pressures possible Each turbine is calibrated according to customer specifications and delivered with individual calibration protocols. (Standard viscosity: 1.3 mm²/s) Liquid Calibration accuracy: Repeatability: Accuracy: Linearity: ±0,05% of measured value ±0,01% of measured value ±0,25% of measured value in the linear flow range ±0.1% of the measured value in the linear flow range Gas Calibration accuracy: Repeatability: Accuracy: Linearity: ±0, 3% of measured value ±0,2% of measured value ±0,60% of measured value in the linear flow range ±0,1% of the measured value in the linear flow range Standard material: Stainless steel TrigasDM GmbH - June
4 Measuring ranges a) Gas Linear Extended max. Range Flowrange K-Faktor 1) Frequenz 1) [ml/min] [ml/min] Model min. max. min. max. [Pulse/ml] [Hz] DML , DML , DML , DML , DML , , ) The K-factors and frequency data are average values. Each turbine is calibrated according to customer specifications and delivered with individual calibration protocols. b) Liquid Linear Extended max. K-Faktor 1) Range Flowrange Frequenz 1) [ml/min] [ml/min] Model min. max. min. max. [Pulse/ml] [Hz] DML 0.6 7,57 75,7 3, DML , DML , DML , DML , ) The K-factors and frequency data are average values. Each turbine is calibrated according to customer specifications and delivered with individual calibration protocols. TrigasDM GmbH - June
5 Dimensions, Align while installing align Model InnerØ DML0.6 0,6 DML1.0 1,0 DML2.0 2,0 DML4.0 4,0 DML5.0 5,0 length A Housing height/depth B 1) Measuring sensor (pickoff) Screw in depth Thread Type 76,2 SW 36* 17,7 5/8-18UNF-2B 1) The total height is calculated from the height (B) of the flow meter plus measuring element minus the screw-in depth. *) AF = Width across flats TrigasDM GmbH - June
6 End Fitting types and operating pressure Female threads (GF) Model DML0.6 - DML5.0 A B [Zoll] 76,2 G1/2 (20,955mm) C max. operating pressure [bar] 0,6 400 NOTE Other end fittings can be supplied on request TrigasDM GmbH - June
7 Piping Configuration Turbine flow meters can be affected by the velocity profile of the fluid being measured. Installation with proper pipe runs will reduce or completely eliminate flow profile induced measurement errors during calibration and operation. Inlet section and outlet section, schematic diagram A straight run of pipe of at least 10 times the pipe diameter in an upstream direction, and 5 times the pipe diameter in a downstream direction are recommended (see figure and table). The upstream section should be fitted with flow straightening vane. Appropriate flow straightening sets (up- and downstream) are available on request. Contamination / filter All pipe sections and components in the metering line must be cleaned prior to the installation of the flow meter. Pipe Sealants, metal shavings and slag can damage the flow meter. If the cleanliness of the fluid cannot be guaranteed, a filter should be installed upstream of the flow meter, subject to the diameter of the flow meter. The selection of the filter depends on the precision opening of the flow meter and the bearing of the rotor. Contamination between the inside of the housing and Pelton wheel can lead to a blockage of the flow. A filter must always be used for gas measurements Model InnerØ Filter mesh size for Jewels Pivot bearing Filter mesh size for Ball bearings DML0.6-0,6 min.100 Mikrometer min.10 Mikrometer DML5.0 TrigasDM GmbH - June
8 Explosion protection (ATEX) All DM-Series turbine flow meters are available in intrinsically safe design. The design consists of the turbine flow meter and the ATEX Pickoff. The following type of protection applies to this construction: - Flow Sensor ATEX: II 1G Ex ia IIC (Zone 0,1,2) - Temperature Sensor ATEX: EX II 2G Ex ib IIC T4 Gb (Zone 1,2) The turbine flow meter is installed in the hazardous area. The mounting of the barrier and the TriLIN is carried out in the safe area. Without barriers, the turbine flow meter must not be operated in the hazardous area. Cable lengths of up to 400 m are possible depending on the safety barrier used. TrigasDM GmbH - June
9 Model Numbering key DML - Serie (z.b. DML-0.6GF-BA-1) DML -0.6 GF -BA -1 Pickoff (f.e. L02 L5 T) L 02 L5 T Construction Material - 1 stainless steel Bearing -BA = Ball bearings, standard -BC = Ball bearings, ceramic -JP = Jewel Pivot Bearing -BA = Ball Bearing End Fitting AN = threaded connection HS = hose connection GF = ½ G Female threads Temperature Sensor T = Integrated in Pickoff 0 = without Connector C2 = MS Connector 2 Pins C3 = MS Connector 3 Pins C4 = MS Connector 4 Pins L1 = 1m cable outlet L3 = 3m cable outlet L5 = 5m cable outlet Thread 01 = 5/8-16, High Profile 02 = 5/8-16, Low Profile 03 = 5/8-16, High Profile, Explosion Proof 04 = 5/8-16, High Profile, High Temp. 06 = 11/16-24, High Profile 07 = 11/16-24, Low Profile 08 = 11/16-24, High Profile, Explosion Proof 09 = 11/16-24, High Profile, High Temp. Base Model Model R = Frequenzmoduliert (RF) M = Magnetisch (Mag) L = Lysis SMART-RF Product Name TrigasDM GmbH - June
TURBINE METER SERIES FMT-S
TURBIN MTR SRIS FMT-S The best way to predict the future is to create it Introduction Typical metrological characteristics 2 1.5 The FMT-S turbine meters are robust and designed to perform on the highest
More informationTurbine Meter. P e
Turbine Meter P 402.003e Turbine Flow Meters Table of Contents Applications of the Turbine Meter RQ Series Page 3 Type RQ for Liquids Page 4 RQ Turbine Meter with UST Universal Transmitter Page 7 RQ Turbine
More informationData Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.
Data Sheet Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology Application Metering and recording of volume or mass flow of gases, liquids and steam. Vortex meter trikon EDZ
More informationVortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)
Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Fluid temperatures up to 400 C (752 F) High accuracy Short inlet
More informationFLUIDISTOR GAS FLOWMETER GD 100 (EX)
FLUIDISTOR GAS FLOWMETER GD 100 (EX) for measuring of all technical and medical gases DN25 - DN400 Oscillating measuring principle, without moving parts Resistent to dirt, e.g. oil and rust residues in
More informationABB Kent-Taylor. Turbine Meter PTF. PTF meter for guaranteed reliability and high accuracy in a turbine meter. Wide flow range up to 40:1
Turbine Meter PTF Wide flow range up to :1 Intrinsically Safe and Flameproof versions available increases range of applications Excellent linearity and repeatability meets fiscal metering standards Linear
More informationData Sheet ANO. Hygienic Type Turbine Flowmeter. Supplied by. .com. Call us on +44 (0)
Data Sheet ANO Hygienic Type Turbine Flowmeter Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com ANO Hygienic Type Turbine Flowmeter Introduction The ANO series flowmeters have been
More informationModel 5100 Model 5400 Insertion Turbine Flowmeters for Liquid and Gas
Model 5100 Model 5400 Insertion Turbine Flowmeters for Liquid and Gas Thermo Scientific insertion turbine flowmeters have provided highly accurate and repeatable flow measurements for large pipeline applications
More informationXMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor
Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Output
More informationCoriolis Mass Flow Meter
Coriolis Mass Flow Meter P Series High Precision Coriolis Mass Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com;
More informationXMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor
Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 00 bar Output
More informationTURBINE METER RQ Series 1 and 2
1. IDENTIFICATION Manufacturer Bopp & Reuther Messtechnik Am Neuen Rheinhafen 4 67346 Speyer / Germany Phone: +49 6232 657-0 Fax: +49 6232 657-505 Product type Indirect volume meter Product name Turbine
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationIntrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables
Data Sheet 907025 Page 1/12 Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables The hygrothermal transducers measure the relative air humidity and temperature
More informationProcess Inline Filter, Change-Over
Process Inline Filter, Change-Over -503-130x -520x 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL Inline filters, types PRFL and duplex inline filters are designed for process engineering and chemical plants.
More informationGas Sample Probe Series SP
Embracing Challenge Gas Sample Probe Series SP Version SP3110V and SP3110 for sampling from zones with explosive gas with different options for calibration gas feeding, back purging and shut-off SP3110V/RS/HE4-135
More informationx act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.
Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output
More informationx act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.
Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output
More informationEUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call
EUROPE S LARGEST SELECTION OF TEST & MEASUREME EQUIPME FOR HIRE INLEC.COM Nationwide Low Call 0333 6000 600 WHY BUY WHEN YOU CAN HIRE Introduction The N ixon range of turbine flowmeters offers high accuracy
More informationSCS-AMM15 : ADMIX SHOTCRETE MEASUREMENT SYSTEM
SCS-AMM15 : ADMIX SHOTCRETE MEASUREMENT SYSTEM Congratulations on choosing a ManuFlo (Manu Electronics) liquid admixture magflow shotcrete measurement system. You will now join many thousands of satisfied
More informationCOMBIMASS. Technical Data COMBIMASS GA-m / GA-e Version
COMBIMASS Technical Data / GA-e Version 2013-05 _- PORTABLE GAS ANALYZER COMBIMASS GA-m/ GA-e For decades now, Binder has been supplying leading plant manufacturers with innovative systems for industrial
More informationFlowmeters. Positive Displacement meter. Coriolis mass flowmeter. Turbine flowmeter. Ultrasonic flowmeter
The Satam range is used for the custody transfer measurement of liquid hydrocarbons, liquid gas and liquid chemicals. Consisting of four distinct families, the range is able to meet the needs of most industrial
More informationField case for temperature transmitter Model TIF11
Electrical temperature measurement Field case for temperature transmitter Model TIF11 WIKA data sheet TE 62.02 Applications Plant construction Process engineering General industrial applications Energy
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO from 0... 00 mbar up to 0... 0 bar Output signals
More informationAPT3200 SMART PRESSURE TRANSMITTER. Range and Sensor Limits Refer to Table 1. Isolation Input/output isolated to 500Vrms (707 Vdc)
Range and Sensor Limits Refer to Table 1 Zero and Span Adjustment Limits Zero and span values can be set anywhere within the range limits stated in Table 1. Span must be greater than or equal to the minimum
More informationVortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam
Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Cost savings due to high accuracy Low investment cost through
More informationSwirl flowmeter FS4000 Compact, reliable and robust
Measurement made easy Swirl flowmeter FS4000 Compact, reliable and robust Simply fi ts your purpose The most important data at a glance Accuracy for liquids ± 0.5% of rate Accuracy for gases and steam
More informationSystem Components. The Top Performers in Material Flow. Components With Experience
System Components The Top Performers in Material Flow Components With Experience Discharging Metering Diverting Sifting Filtering Optimize your Raw Material Handling! 1 Perfectly coordinated raw material
More informationEC type-examination certificate UK/0126/0094 Revision 5
UK/0126/0094 MI-001 EC type-examination certificate UK/0126/0094 Revision 5 issued by: The National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments
More informationGilflo flowmeters. for steam, liquids and gases
Gilflo flowmeters for steam, liquids and gases The Gilflo spring loaded variable area flowmeter... offers an unrivalled 1:1 turndown and can be used to meter most industrial fluids including steam and
More informationLutz Flow Meter Program
Lutz Flow Meter Program A flexible friend: Lutz flow meter TS Mixing and Matching: The modular flow meter system TS offers almost unlimited application possibilities. You are free to select the basic meter,
More informationVERIS Accelabar. Superior Flow Measurement Accuracy
VERIS Superior Flow Measurement Accuracy Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. ...A New Idea in Flow
More informationLMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.
Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma -wire: 0 0 V others on request
More informationThe Unique Accelabar Flow Meter
The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.
More informationTUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU
TUFFy T3 side Mounting level controls Tuffy liquid level switches are float actuated devices designed for horizontal mounting in a tank or vessel through threaded or flanged pipe connections. The compact
More informationProsonic Flow B 200. For reliable flow measurement of biogas without limitations
Prosonic Flow B 200 For reliable flow measurement of biogas without limitations Specially designed ultrasonic flowmeter for measuring biogas, landfill or digester gas One-of-a-kind direct measurement of
More informationILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.
ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma
More informationPressure transducers DMU 02 Vario (flush)
Process engineering (flush) Ideal for hygienic processes Connection technology with numerous versions Extremely resistant to shock, pulsation and vibration Best dynamic pressure resistance at high load
More informationCALDON LEFM Ultrasonic Flowmeters for Gas Applications. Integrating experience, proven technology, and innovation
CALDON LEFM Ultrasonic Flowmeters for Gas Applications Integrating experience, proven technology, and innovation Four-path CALDON LEFM 340Ci ultrasonic flowmeter. Contents Count on Cameron........................................................................3
More informationQUALITY INDUSTRIAL FLOWMETERS
QUALITY INDUSTRIAL FLOWMETERS COMPANY PROFILE Trimec Industries is an Australian owned ISO9001:2008 quality certified company specializing in the design and manufacture of a proprietary range of positive
More informationLIQUID METER TYPE FMO
LIQUID METER TYPE FMO INNOVATORS IN FLOW TECHNOLOGY FLUX LIQUID METER TYPE FMO OVAL ROTOR DESIGN FLUX liquid meters type FMO are positive displacement flowmeters according to the oval rotor design. They
More informationOM... Screw-Type Volumetric Flow Meter. for Viscous Media. Measuring ranges: l/min liquid
Screw-Type Volumetric Flow Meter for Viscous Media measuring monitoring analysing OM... Measuring ranges: 0.-0... 0-000 l/min liquid OMeasuring O accuracy: ± 0.% of span : 00 ± 0.% of span : 0 p max :
More informationKRAL Volumeter - OME Series Economy Flowmeters
KRAL Volumeter - OME Series Economy Flowmeters OME - Economy OME A unique concept for economical flow measurement Operating Conditions and Materials Flow Range: 0.03 to 40 gpm Max. Pressure: 600 psi Temperature
More informationCertified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationKRAL Volumeter - OMG Series Universal Flowmeters
KRAL Volumeter - OMG Series Universal Flowmeters OMG - Universal OMG Flowmeters for a Wide Range of Applications Operating Conditions and Materials Flow Range: 0,1 to 7500 l/min Max. Pressure: 250 bar
More informationHandling Fluid Fertilizers Selecting the Right Equipment Components
Handling Fluid Fertilizers Selecting the Right Equipment Components 9/2/2010 1 Considerations Systematic approach Compatible components Short term vs. long term Plan ahead for future expansion 9/2/2010
More informationPresentation Overview
Presentation Overview 1. Who is Hoffer Flow Controls? 2. Show me the money (benefits)! 3. Aren t t there other flowmeters that are better? 4. How Hoffer flowmeters can help you. 1 Hoffer has supplied flowmeters
More informationRUNYI GROUP. Main Features. STLU Vortex Flow Meter
STLU Vortex Flow Meter Main Features STLU Intelligent Vortex Flow Transducer is piezocrystal built in bluff body to avoid fluid turbulence caused by external type, no zero drift, and high reliability.
More informationOPTIMASS 7400 Technical Datasheet
OPTIMASS 7400 Technical Datasheet Sensor for mass flow The optimum meter for demanding applications A single straight measuring tube Choice of 4 tube materials The documentation is only complete when used
More informationVLM10 In-line Vortex Mass Flow Meter
VLM10 In-line Vortex Mass Flow Meter Description The VLM10 in-line vortex flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process
More informationPlastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases
Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or
More informationFlow measurement of Liquids and Gases
Flow measurement of Liquids and Gases Metallic construction Operates horizontally or vertically DN 40 to DN 500 Flow rate: - Water: 0.8 m 3 /h up to 1600 m 3 /h. - Air: 45 Nm 3 /h up to 24000 Nm 3 /h.
More informationKDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...
All Metal Variable Area Flowmeter for liquids and gases measuring monitoring analysing : 0.1-1 l/h... 20-200 l/h water 5 - Nl/h... 600-6000 Nl/h Accuracy: ±3 % of full p max : 420 bar; t max : 130 C OConnection:
More informationKRAL Volumeter - OMG Series Universal Flowmeters
KRAL Volumeter - OMG Series Universal Flowmeters OMG - Universal OMG Flowmeters for a Wide Range of Applications Operating Conditions and Materials Flow Range: 0.03 to 2000 gpm Max. Pressure: 3600 psi
More informationDischarge systems for difficult to handle bulk materials
Discharge systems for difficult to handle bulk materials Difficult to handle bulk materials SHW Schwäbische Hüttenwerke is a traditional company that has been trading for 640 years and since the 1960s
More informationGilflo ILVA flowmeters for steam, liquids and gases
Gilflo ILVA flowmeters for steam, liquids and gases The Gilflo in-line variable area (ILVA) flowmeter... is a revolutionary development of the well established family of Gilflo flowmeters that has been
More informationEE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features
EE300ExHT The EE300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Serving the Gas Industry Worldwide
Turbine Meter TRZ 0 PRODUCT INFORMATION Serving the Gas Industry Worldwide TURBINE METER TRZ 0 Methode of operation, Construction Methode of operation The TRZ 0 turbine meter is a flow meter suitable for
More informationRHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits
RHM80 High Flow Coriolis Mass Flow Meter Features Standard pressure ratings up to 341 bar (4946 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down to 0.15% Density uncertainty
More informationContrans P Transmitter. Integral Orifice Assembly / EN. Measuring section for the measurement of small flow quantities
Contrans P Transmitter Integral Orifice Assembly Measuring section for the measurement of small flow quantities 10/ 1460.BMP Measuring Media: Liquids, Gases (Vapors) Flow Measurement from 1.5 l/h (at =
More informationTRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY
Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass flow, volume flow, temperature and density and consequently can replace different
More informationProline Prosonic Flow B 200 For reliable biogas flow measurement without compromise
HAASE Energietechnik AG, Neumünster Proline Prosonic Flow B 200 For reliable biogas flow measurement without compromise Process monitoring and energy balancing made easy Innovative measurement industry-optimized
More informationRHM60. Coriolis Mass Flow Meter with Uncompromising Performance. Features. Applications. Benefits
RHM60 Coriolis Mass Flow Meter with Uncompromising Performance Features Standard pressure ratings up to 490 bar (7107 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down
More informationEE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features
EE300ExHT The EE300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone
More informationHTM series. The Helical Turbine Meter for Custody Transfer Application
series // Page LE Leaflet The Helical Turbine Meter for Custody Transfer Application Features & benefits Applications Low to high viscosity design for single or FSO's & FPSO's custody transfer multiviscosity
More informationProduct Data Sheet. Turbine Flow Meters. Precision Series Gas Meters DESCRIPTION OPERATION APPLICATION CALIBRATIONS
Turbine Flow Meters Precision Series Gas Meters ESCRIPTION Cox Precision Gas Flow Meters are designed for precise and repeatable flow measurement of all compressible fluids, with the added benefit of minimal
More informationT.E. (Mech., Mech. S/W) (Semester II) Examination, 2011 TURBOMACHINES (New) (2008 Pattern)
*4063218* [4063] 218 T.E. (Mech., Mech. S/W) (Semester II) Examination, 2011 TURBOMACHINES (New) (2008 Pattern) Time : 3 Hours Marks : 100 Instructions : 1) Answer any three questions from each Section.
More informationSERIES OVAL GEAR FLOWMETER MOGF
SERIES OVAL GEAR FLOWMETER MOGF Fluidex series MOGF is a Positive Displacement Flow Meter with medium capacity. The meters have two rotating gears in oval-shape. A fixed amount of the liquid passes between
More informationHigh Temperature Pressure Sensor
Pressure High Temperature Pressure Sensor for Gas Turbine- and Thermoacoustics Applications Differential, acceleration compensated, piezoelectric pressure sensor for operation temperatures up to 700 C.
More informationInstruction Manual. Pressure Relief Valve. PRV22 (All Models) PRV16 (All Models)
Pressure Relief Valve PRV22 (All Models) PRV6 (All Models) Page 2 of 20 Issue: 4.0 General Description The Binks mechanical Pressure Relief Valve offers a practical solution for the prevention of Smart
More informationCHAPTER 6 : GAS SAMPLING SYSTEMS
CHAPTER 6 : GAS SAMPLING SYSTEMS 1 Scope : 1.1 This Chapter describes two types of gas sampling systems in paragraphs 2.1 and 2.2 meeting the requirements specified in para 4.2 of Chapter 3 of this Part.
More informationPro-V Multivariable Flowmeter Model M23 Insertion Vortex
Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationModule 8 Its Not Just About the Meter and Regulator
Station Types Point of Delivery (POD) Point of Receipt (POR) Industrial Commercial Residential OGA 2015 Regulator Fundamentals Seminar 2 Station Design Information Upstream pipeline MAOP Inlet pressure
More information7000 Series Liquid Turbine Meters
BARTON 000 Series Liquid Turbine Meters Models 1xx, xx, & 3xx Barton 000 series turbines are designed for a broad range of precise liquid measurement applications. Based on 35 years of turbine manufacturing,
More informationE 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min
Return Filters E 9 E E Tank top mounting Connection up to G Nominal flow rate up to l/min Description Application In the return line circuits of hydraulic systems. Performance features Protection against
More informationMulti Ejector Solution TM for R744 (CO 2 ) Type - CTM 6 High Pressure (HP)
Data sheet Multi Ejector Solution TM for R744 (CO 2 ) - CTM 6 High (HP) Multi Ejector Solution TM, consists of a CTM 6 High valve and an AK-PC 782A controller. This solution makes CO 2 refrigeration systems
More informationFlow & process measurement solutions
Flow & process measurement solutions UK Flowtechnik Specialists in flow metering, pumps, couplings and process measurement equipment Flow & process measurement solutions Flow Temperature Pressure Level
More informationEletta Flow Monitor for use in explosive atmospheres
NEWThe V-Ex Eletta Flow Monitor for use in explosive atmospheres For some time there has been a demand from the market to offer explosion proof versions. An increasing number of customers and end users
More informationDatasheet Rev.4 Jan 2015 Orifice plate - Overview
Datasheet Rev.4 Jan 2015 Orifice plate - Overview Orifice plate design based on ISO5167, BS1042, ASME.MFC.3M and ISO TR15377 :2007 industry standards Accuracy, repeatability and reliability of the flow
More informationMulti Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low Pressure (LP)
Data sheet Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low (LP) Danfoss Multi Ejector Solution TM, consists of a CTM 6 Low valve and an AK-PC 782A controller. This solution makes CO
More informationFilling Systems. Conception Engineering Service
Filling Systems Conception Engineering Service Knowledge and skills are tradition at FRICKE FRICKE Dosing + Filling Systems prove themselves worldwide on a daily basis. In addition to German-made, fully
More informationDiaphragm pressure gauge
Diaphragm pressure gauge with switch function, NS 00/60,Type series BE2 Features Diaphragm pressure gauge with switch function High quality case with bajonet ring NS 00/60 per EN 837-3 S, alternative safety
More informationzahnrad_neu_gb :46 Uhr Seite 1 Gear Pumps
Gear Pumps Kreyenborg Gear Pumps - An Addition to our Range The best guarantee for continuous and economic machine performance is a closed loop system with well-matched units. The Kreyenborg system, right
More information12 Temperature measurement SCT analogue
12 Temperature measurement SCT analogue Temperature measurement SCT analogue High-pressure-resistant temperature sensors For measuring temperatures up to 1,000 C Flexible operation Inline or probe-type
More informationQSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses
Flowmeters QSE MAG FLOW METER Non-Intrusive (No moving parts) Electromagnetic Flow Meter Turf / Irrigation Agriculture Irrigation Turf Irrigation Systems Micro Irrigation Systems Institutional Chilled
More informationheliflu tm The Dedicated Turbine Flowmeter for Custody Transfer Measurement Proven Performance Main Applications
heliflu tm tzn The Dedicated Turbine Flowmeter for Custody Transfer Measurement Proven Performance Main Applications Oil Production Allocation FSO, FPSO Metering Tanker Loading/Offloading Storage Management
More informationHLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features
HLX300ExHT The HLX300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone
More informationRobust flue gas probes for industrial emissions measurements.
Robust flue gas probes for industrial emissions measurements. For reliable measurements using testo 340 and testo 350, even in the harshest of conditions. Robust flue gas probes for industrial emissions
More informationSentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications
GE Sensing & Inspection Technologies Sentinel LNG Panametrics Ultrasonic Flowmeter for Cryogenic Liquids Benefits Improved performance, reduced maintenance and dynamic flow measurement is now available
More informationHumidity/temperature measuring instrument
Humidity/temperature measuring instrument testo 645 Highly precise measurements for industry Highly accurate humidity measurement up to ±1 %RH %RH Connection of 2 plug-in probes Measurement of temperature,
More informationPitot tube Model FLC-APT-E, extractable version Model FLC-APT-F, fixed version
Flow measurement Pitot tube Model FLC-APT-E, extractable version Model FLC-APT-F, fixed version WIKA data sheet FL 10.05 FloTec Applications Oil production and refining Water treatment and distribution
More informationSITRANS P measuring instruments for pressure
Overview Supplementary electronics for 4-wire connection Structural design Dimensions (W x H x D) in mm (inch) Electrical connection 80x10x60 (3.15x4.7x.36) Screw terminals (Pg 13.5 cable inlet) or Han
More informationFlow Assembly for ph and Redox Sensors FlowFit P CPA 240
Technical Information TI 179C/07/en Flow Assembly for ph and Redox Sensors FlowFit P CPA 40 ph flow assembly for demanding processes with high requirements. Sensor holder with three electrode mounting
More informationSPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE
SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE C20 C21 C26-2 C26-2 1 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded configuration
More informationDorot Irrigation Meter
DIM-A Irrigation Meter Application The DIM meter is designed for agriculture control applications. The turbine is located at the top of the pipe. Major section of the pipe is free for water flow. Features
More informationSPRING LOADED THERMOCOUPLE CONFIGURATIONS
SPRING LOADED THERMOCOUPLE CONFIGURATIONS FOR USE WITH THERMOWELLS II 3G Ex na/nl TCRN/WN/TN S30 S31 S36-1 S36-2 1 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded configuration guarantees
More informationSentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications
GE Sensing & Inspection Technologies Sentinel LNG Panametrics Ultrasonic Flowmeter for Cryogenic Liquids Benefits Improved performance, reduced maintenance and dynamic flow measurement is now available
More informationMoisture analyzers (moisture meters) FIZEPR-SW100
www.fizepr.ru Design Bureau FIZELEKTRONPRIBOR Moisture analyzers (moisture meters) FIZEPR-SW100 for liquid, paste-like and bulk materials including petroleum, fuel oil, sand, coal, ore, concrete mixture,
More informationDifferential pressure measuring instrument
Differential pressure measuring instrument testo 521 Precise Pitot tube measurement Temperature-compensated differential pressure sensor in instrument Additional 2 probe inputs for the connection of further
More informationPresented By. NicolScales.com Contact Us
Presented By Dallas Ft Worth ustin Houston NicolScales.com 800.225.8181 Contact Us Nicol Scales & Measurement is an ISO ccredited Calibration Company that has provided calibration, repair and sales of
More information