Good (4 points each) > mg/m Bq m Bq m Bq m -3 < ,000 1,000-10,000 10, ,000

Size: px
Start display at page:

Download "Good (4 points each) > mg/m Bq m Bq m Bq m -3 < ,000 1,000-10,000 10, ,000"

Transcription

1 Rating (5 points each) (4 points each) (3 points each) (2 points each) (1 point each) Temperature ( C) C Plus or minus 1 C (including Plus or minus 2 C (including Plus or minus 3 C (including Plus or minus 4 C or more (including Carbon Dioxide (PPM) Relative Humidity (% RH) < > < 40 / > 60 < 30 / > 70 < 20 / > 80 < 10 / > 90 Carbon Monoxide > mg/m 3 Nitrogen Dioxide TVOC < > < > Formaldehyde Radon (Bq m3) Particulate matter < mg/m3 > Bq m Bq m Bq m > Laser Particle counter 0.3 ug 0.5 ug 1.0 ug 2.5 ug 5.0 ug 10.0 ug 0 100, , , ,001-50,000 35,201 87,500 8,321 20, , ,001 > 87,501 > 20,801 > 1,363 > 484 > 171 > Viable air sampling (CFUs) < ,000 1,000-10,000 10, ,000 > 100,000 Occupant s perception of comfort (%) 100% of 90-99% of 80-89% of 70-79% of Under 70% of Odour odours as Clearly acceptable odours as Acceptable odours as Neutral odours as Just not acceptable odours as Clearly not acceptable Overall Rating < 25 The above data provides indicators for a healthy indoor environment; however, specific contaminates that present a risk should be investigated, such as specific species of mould, fibrous materials and particular chemical compounds. Reference to be made to relevant documentation, such as the HSE s EH40 document. Synergistic effects should be considered.

2 18-21 C The Building Research Establishment. Temperature ( C) Plus or minus 1 C (including. Plus or minus 2 C (including. Plus or minus 3 C (including. Plus or minus 4 C or more (including occupied rooms,. Below 600 PPM Carbon Dixoide (PPM) PPM PPM PPM 1800 PPM % RH < 40 / > 60 % RH Relative Humidity (% RH) < 30 / > 70 % RH < 20 / > 80 % RH < 10 / > 90 % RH 0 mg/m 3 (0.8 ppm) - - Carbon monoxide 1-7 mg/m 3 (5.6 ppm) WHO European guidelines recommend not exceeding 7 mg/m mg/m 3 (5.6 ppm) >

3 < 0.2 mg/m Nitrogen mg/m 3 annual average indoor nitrogen dioxide of 40 WHO air quality guideline recommends an μg/m > mg/m 3 3 < 0.1 mg/m mg/m TVOC mg/m ng/l as the upper TVOC limit mg/m 3 TVOC levels between 500 and 1,500 ng/l indicate that air quality is marginal and some effect on the is possible. 1.0 > mg/m 3 levels above 1,500 ng/l indicate that IAQ should definitely be improved. 3 < 0.02 mg/m mg/m 3 LEED / BREAM. Formaldehyde mg/m mg/m mg/m 3 > No standards, however WHO proposed guideline of 0.21 mg/m3 for the protection of long-term health effects, including cancer.

4 0 Bq m Radon (Bq m -3 ) -3 The average level in UK homes is 20 Bq m Bq m Public Health England Bq m -3 Target Level of 100 Bq m-3 is the ideal outcome - Public Health England. Above 100 Bq m -3 levels should be reduced in homes where the average is more than 200 becquerels per Public Health England recommends that radon metre cubed (200 Bq m -3 ). Particulate matter > Laser Particle counter 0.3 µm 0 100, µm 0 35, µm 0 8, µm µm µm µm 100, , µm 35,201-87, µm 8,321-20, µm 546-1, µm µm µm 250,001 > 0.5 µm 87,501 > 1.0 µm 20,801 > 2.5 µm 1,363 > 5.0 µm 484 > 10.0 µm 171 >

5 Viable air sampling (CFUs) Below 1,000 CFUs of mould per gram in a culture sample plate. 1,000-10,000 CFUs of mould per gram in a culture sample plate equals low mould contamination level. 10, ,000 CFUs of mould per gram in a culture sample plate equals medium mould contamination level. 100,000-1,000,000 CFUs of mould per gram in a culture sample plate equals medium to heavy mould contamination level. Interministerial Committee on Indoor Air Quality. Ministry of Labour (MOL) Ontario, Canada, Report. > 1,000,000 CFUs of mould per gram in a culture sample plate equals heavy. 100% of with 90-99% of with Perception of comfort (%) 80-89% of with ASHRAE Standard 55, Thermal Environmental Conditions for Human Occupancy % of with Under 70% of with No standard, however, research indicates 69% of people dis with their indoor environment (Riggs, 2014). Odour (%) odours as Clearly acceptable. odours as Acceptable. odours as Neutral. odours as Just not acceptable. odours as Clearly not acceptable.

Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017

Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017 Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017 What is Indoor Air Quality? Appropriate IAQ can be defined as a function of three different components: 1) appropriate thermal comfort,

More information

Mechanical vs. Natural Ventilation in Schools: Less Can Be More

Mechanical vs. Natural Ventilation in Schools: Less Can Be More Mechanical vs. Natural Ventilation in Schools: Less Can Be More Brad Stanley Purafil, Inc. Seminar 5 -Natural Ventilation in Schools: Boon or Bust? ASHRAE Annual Meeting Long Beach, California June 24-27,

More information

Analysis of VOCs & Formaldehyde

Analysis of VOCs & Formaldehyde Analysis of VOCs & Formaldehyde Indoor air quality testing in homes, schools & offices Tim Robinson Waverton Analytics Ltd Tim_Robinson@wavertonanalytics.com Preview Factors that define or influence indoor

More information

What s in the Air - Truths, Myths & Simple Strategies

What s in the Air - Truths, Myths & Simple Strategies What s in the Air - Truths, Myths & Simple Strategies Presented By: Marek Plawinski, M.Sc., MPH, R.Kin. About Inc. Workshop Objectives 1. What is indoor Air Quality 2. IAQ Investigation 3. Simple Field

More information

Thermal Comfort and Indoor Air Quality Evaluation of Hospital Patient Ward in Malaysia

Thermal Comfort and Indoor Air Quality Evaluation of Hospital Patient Ward in Malaysia Thermal Comfort and Indoor Air Quality Evaluation of Hospital Patient Ward in Malaysia F. AZIZPOUR, S. MOGHIMI, E. SALLEH, S.MAT, C.H.LIM, K. SOPIAN Solar Energy Research Institute, Universiti Kebangsaan

More information

Indoor Air Quality Assessments during Renovations at Waverly Elementary School Project #J (January 4, 12, 15, 25 and 29, 2018)

Indoor Air Quality Assessments during Renovations at Waverly Elementary School Project #J (January 4, 12, 15, 25 and 29, 2018) March 29, 2018 Mr. Jeff Klenk Howard County Public School System (HCPSS) 10910 Route 108 Ellicott City, MD 21043 RE: Indoor Air Quality Assessments during Renovations at Waverly Elementary School Project

More information

Do European standards for indoor air quality take into account outdoor air quality? Professor Bjarne W. Olesen, PhD, Department of Civil Engineering

Do European standards for indoor air quality take into account outdoor air quality? Professor Bjarne W. Olesen, PhD, Department of Civil Engineering Do European standards for indoor air quality take into account outdoor air quality? Professor Bjarne W. Olesen, PhD, Department of Civil Engineering Technical University of Denmark Global impact on people

More information

INDOOR AIR QUALITY AND ENERGY EFFICIENCY IN THE DESIGN OF BUILDING SERVICES SYSTEMS FOR SCHOOL CLASSROOMS

INDOOR AIR QUALITY AND ENERGY EFFICIENCY IN THE DESIGN OF BUILDING SERVICES SYSTEMS FOR SCHOOL CLASSROOMS INDOOR AIR QUALITY AND ENERGY EFFICIENCY IN THE DESIGN OF BUILDING SERVICES SYSTEMS FOR SCHOOL CLASSROOMS KL Tam * Architectural Services Department, the Government of Hong Kong Special Administrative

More information

AIR QUALITY ASSESSMENT FOR TAYLOR STANLEY MARKETING PTE LTD 71, TANNERY LANE #-7-07, CITY INDUSTRIAL BUILDING SINGAPORE

AIR QUALITY ASSESSMENT FOR TAYLOR STANLEY MARKETING PTE LTD 71, TANNERY LANE #-7-07, CITY INDUSTRIAL BUILDING SINGAPORE Our Ref: ATS/IH/84/05KKL Date: 26 August, 2005 Page 1 of 33 AIR QUALITY ASSESSMENT FOR TAYLOR STANLEY MARKETING PTE LTD 71, TANNERY LANE #-7-07, CITY INDUSTRIAL BUILDING SINGAPORE 347807 Date of Survey

More information

ISO INTERNATIONAL STANDARD. Building environment design Indoor air quality Methods of expressing the quality of indoor air for human occupancy

ISO INTERNATIONAL STANDARD. Building environment design Indoor air quality Methods of expressing the quality of indoor air for human occupancy INTERNATIONAL STANDARD ISO 16814 Fist edition 2008-10-15 Building environment design Indoor air quality Methods of expressing the quality of indoor air for human occupancy Conception de l'environnement

More information

International Perspective on Clean Air and Energy Efficiency in Buildings. Morad R. Atif, PhD. Director, Architectural Engineering

International Perspective on Clean Air and Energy Efficiency in Buildings. Morad R. Atif, PhD. Director, Architectural Engineering International Perspective on Clean Air and Energy Efficiency in Buildings Morad R. Atif, PhD. Director, Architectural Engineering Architectural Engineering at Texas A&M New Bachelor of Science in Interdisciplinary

More information

INDOOR AIR QUALITY OF AIR-CONDITIONED FOOD COURTS: PRELIMINARY FINDINGS IN A TROPICAL CITY STATE

INDOOR AIR QUALITY OF AIR-CONDITIONED FOOD COURTS: PRELIMINARY FINDINGS IN A TROPICAL CITY STATE Proceedings: Indoor Air 2 INDOOR AIR QUALITY OF AIR-CONDITIONED FOOD COURTS: PRELIMINARY FINDINGS IN A TROPICAL CITY STATE HM Yap * and PL Ooi 1 1 Department of Quarantine & Epidemiology, Ministry of The

More information

INVESTIGATION OF INDOOR ENVIRONMENTAL QUALITY AND PRODUCTIVITY IN MONITORED OFFICES IN SLOVAKIA

INVESTIGATION OF INDOOR ENVIRONMENTAL QUALITY AND PRODUCTIVITY IN MONITORED OFFICES IN SLOVAKIA Proceedings of the 14 th International Conference on Environmental Science and Technology Rhodes, Greece, 3-5 September 2015 INVESTIGATION OF INDOOR ENVIRONMENTAL QUALITY AND PRODUCTIVITY IN MONITORED

More information

A Study of Indoor Environmental Quality Parameters in a South Central Kentucky Daycare Facility

A Study of Indoor Environmental Quality Parameters in a South Central Kentucky Daycare Facility A Study of Indoor Environmental Quality Parameters in a South Central Kentucky Daycare Facility Emmanuel Iyiegbuniwe, Ph.D. Western Kentucky University Bowling Green, KY 42101 Introduction Rapid advances

More information

Indoor Environmental Quality Policy

Indoor Environmental Quality Policy University of Florida Indoor Environmental Quality Policy For New Construction and Renovation Environmental Health and Safety Division June 2009 Introduction Effective management of the indoor environmental

More information

Performance Indicators for Health, Comfort and Safety of the Indoor Environment (PERFECTION)

Performance Indicators for Health, Comfort and Safety of the Indoor Environment (PERFECTION) Performance Indicators for Health, Comfort and Safety of the Indoor Environment (PERFECTION) Paul Steskens Jan Desmyter Pierre-Henri Lefèbvre Belgian Building Research Institute (BBRI) Contents Introduction

More information

Indoor Air Quality. Basic Management for Healthy Office Environments. Peter A Shelling CSP CIEC

Indoor Air Quality. Basic Management for Healthy Office Environments. Peter A Shelling CSP CIEC Indoor Air Quality Basic Management for Healthy Office Environments Peter A Shelling CSP CIEC Why is Indoor Air Quality (IAQ) a problem now? People spend more time indoors than ever before (90% for most

More information

Overview of Dynamic Control of Lab ACH s

Overview of Dynamic Control of Lab ACH s A Comprehensive Review of the Indoor Environmental Quality and Energy Impacts of Dynamically Varying Air Change Rates at Multiple Laboratory Facilities Overview of Dynamic Control of Lab ACH s Background

More information

Comparison of indoor air quality on a passenger ship and a chemical ship

Comparison of indoor air quality on a passenger ship and a chemical ship Indoor Air 28, 17-22 August 28, Copenhagen, Denmark - Paper ID: 49 Comparison of indoor air quality on a passenger ship and a chemical ship Sun-Sook Kim 1,*, Yoon-Kyung Kang 1, Geun-Young Doe 2 and Yun-Gyu

More information

Chapter 14 Indoor Air Quality

Chapter 14 Indoor Air Quality Chapter 14 Indoor Air Quality 1 Indoor Environment and Built Environment Buildings Transportations vehicles 2 1 Indoor Air Quality (IAQ) Indoor air quality (IAQ) is the quality of air in an indoor environment.

More information

UBC Social Ecological Economic Development Studies (SEEDS) Student Report

UBC Social Ecological Economic Development Studies (SEEDS) Student Report UBC Social Ecological Economic Development Studies (SEEDS) Student Report Indoor Air Quality Assessment CHBE building Second floor Bojosi Gamontle, Jackie Law, Navid Taherdin University of British Columbia

More information

Indoor Air Quality Solutions

Indoor Air Quality Solutions Indoor Air Quality Solutions Ultimate Solutions for Indoor Air Quality Investigation Demand for quality indoor air continues to increase as we are spending more time indoors than ever before. Indoor air

More information

Post-occupancy Evaluation of Green Buildings Are they as green as we thought? Guy Newsham, Ph.D. and colleagues

Post-occupancy Evaluation of Green Buildings Are they as green as we thought? Guy Newsham, Ph.D. and colleagues Post-occupancy Evaluation of Green Buildings Are they as green as we thought? Guy Newsham, Ph.D. and colleagues Introduction How do green buildings perform when occupied? Indoor Environment Quality, Occupant

More information

ISO INTERNATIONAL STANDARD. Building environment design Indoor air quality Methods of expressing the quality of indoor air for human occupancy

ISO INTERNATIONAL STANDARD. Building environment design Indoor air quality Methods of expressing the quality of indoor air for human occupancy INTERNATIONAL STANDARD ISO 16814 Fist edition 2008-10-15 Building environment design Indoor air quality Methods of expressing the quality of indoor air for human occupancy Conception de l'environnement

More information

Indoor Air Quality Assessment Report

Indoor Air Quality Assessment Report Indoor Air Quality Assessment Report For M&W Business Centre At Unit B, 19/F, Kyoto Plaza, 491-499 Lockhart Road, Causeway Bay, Hong Kong Tel: 3896 0399 Attn: Melody Ko Tested and prepared by: Carman Lam

More information

IAQ benchmarks of air-conditioned offices in Hong Kong

IAQ benchmarks of air-conditioned offices in Hong Kong Indoor Air 2008, 7-22 August 2008, Copenhagen, Denmark - Paper ID: 20 IAQ benchmarks of air-conditioned offices in Hong Kong K.W. Mui *, L.T. Wong ** and P.S. Hui Department of Building Services Engineering,

More information

Visible emissions were not observed in the school in the vicinity of the construction containment.

Visible emissions were not observed in the school in the vicinity of the construction containment. April 23, 2018 To: Waverly Elementary School From: Christopher Madden, CIH Indoor Environmental Quality Manager Re: Indoor Air Quality Testing During Renovations - March As Waverly Elementary School is

More information

White paper: Indoor air quality and carbon dioxide sensors

White paper: Indoor air quality and carbon dioxide sensors White paper: Indoor air quality and carbon dioxide sensors January 30, 2017 Author: Markku Rouvala, Hardware Design manager, New Nordic Engineering. Email: mr@n.build Indoor air quality depends mostly

More information

Visible emissions were not observed in the school in the vicinity of the construction containment.

Visible emissions were not observed in the school in the vicinity of the construction containment. June 22, 2018 To: Waverly Elementary School From: Christopher Madden, CIH Indoor Environmental Quality Manager Re: Indoor Air Quality Testing During Renovations - May As Waverly Elementary School is currently

More information

Assessment of Indoor Environment Quality on Occupant Wellbeing and Educational Outcomes

Assessment of Indoor Environment Quality on Occupant Wellbeing and Educational Outcomes Assessment of Indoor Environment Quality on Occupant Wellbeing and Educational Outcomes 20 th September 2017 TEMC www.cetec.com.au Authors Ben Lindsay CETEC Pty Ltd Consultant Vyt Garnys CETEC Group of

More information

AIRBORNE PARTICULATE MATTER WITHIN 100 RANDOMLY SELECTED OFFICE BUILDINGS IN THE UNITED STATES (BASE)

AIRBORNE PARTICULATE MATTER WITHIN 100 RANDOMLY SELECTED OFFICE BUILDINGS IN THE UNITED STATES (BASE) Proceedings of Healthy Buildings, Vol. 1 157 AIRBORNE PARTICULATE MATTER WITHIN 1 RANDOMLY SELECTED OFFICE BUILDINGS IN THE UNITED STATES (BASE) L.E. Burton, J.G. Girman, S.E. Womble Indoor Environments

More information

Development of WHO guidelines on indoor air quality

Development of WHO guidelines on indoor air quality Indoor Air 2008, 17-22 August 2008, Copenhagen, Denmark - Paper ID: Tu9K1 Development of WHO guidelines on indoor air quality Michal Krzyzanowski * WHO European Centre for Environment and Health, Bonn,

More information

ASHRAE s. Indoor Air Quality Procedure. in Ventilation Design

ASHRAE s. Indoor Air Quality Procedure. in Ventilation Design Elliott Horner, PhD UL Environment elliott.horner@ul.com M: 678-249-8856 ASHRAE s Indoor Air Quality Procedure Jim Dennison, CIH, PhD Century Environmental Hygiene jim@centuryenvironmental.com O: 970-266-8000

More information

Indoor Air Quality (IAQ) Requirements

Indoor Air Quality (IAQ) Requirements University of New Hampshire University of New Hampshire Scholars' Repository Division 01 General Requirements Chapter 5 Technical Construction and Renovation Standards 1-25-2013 013560 - Indoor Air Quality

More information

Scope of application. Definitions. Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Social Affairs and Health

Scope of application. Definitions. Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Social Affairs and Health Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Social Affairs and Health Decree of the Ministry of Social Affairs and Health on Health-related Conditions of Housing and

More information

Quality and Performance in Construction Delivered by Trusted expertise for the product manufacturing sector

Quality and Performance in Construction Delivered by Trusted expertise for the product manufacturing sector Quality and Performance in Construction Delivered by Building responsibly World-class high performing supply chains & products you can build on Trusted expertise for the product manufacturing sector www.bregroup.com

More information

Can we rely on good ventilation? IAQ and ventilation effectiveness

Can we rely on good ventilation? IAQ and ventilation effectiveness FM Nectar Can we rely on good ventilation? IAQ and ventilation effectiveness Presented by Ian Mawditt February 2017 London Healthy Buildings Conference slide 2 Slide from Tom Woolley presentation, October

More information

IAQ Workshop. Assessing Common IAQ Contaminants and Ventilation Systems. Dru Sahai

IAQ Workshop. Assessing Common IAQ Contaminants and Ventilation Systems. Dru Sahai IAQ Workshop Assessing Common IAQ Contaminants and Ventilation Systems Dru Sahai Public Health Ontario Indoor air quality workshop CIPHI National Meeting Winnipeg, MB June 22, 2013 Outline Introduction

More information

A Comparison of the Approaches in the Implementation of Good Indoor Air Quality Practices in Malaysia

A Comparison of the Approaches in the Implementation of Good Indoor Air Quality Practices in Malaysia A Comparison of the Approaches in the Implementation of Good Indoor Air Quality Practices in Malaysia Anuar Mohd. Mokhtar* Department of Occupational Safety & Health, Malaysia *Corresponding email: anumokh@hotmail.com

More information

Demand-Based Control of Laboratory Air Change Rates

Demand-Based Control of Laboratory Air Change Rates Demand-Based Control of Laboratory Air Change Rates Gordon P. Sharp Chairman Aircuity,, Inc. Aircuity Project: Bank of America Tower, NYC Research Laboratory Energy: Why Do We Care? Lab Energy Usage: 5

More information

A SURVEY OF INDOOR AIR QUALITY PROBLEMS IN AIR-CONDITIONED BUILDINGS IN INDIA

A SURVEY OF INDOOR AIR QUALITY PROBLEMS IN AIR-CONDITIONED BUILDINGS IN INDIA A SURVEY OF INDOOR AIR QUALITY PROBLEMS IN AIR-CONDITIONED BUILDINGS IN INDIA S Kalaiselvam 1, * JR Robin 1, S Jose 2,S Iniyan 1, AA Samuel 3 1 Department of Mechanical Engineering, Anna University, Chennai

More information

Aircuity Installation

Aircuity Installation Aircuity Installation Project Team Project Services Allen Shiroma Asst. Director Renovations Matt Gudorf Campus Energy Manager Adam Feuerstein Project Manager EH&S Lisa Mahar - Senior Mgr, Occupational

More information

THE IMPACTS OF HUMAN ACTIVITIES ON INDOOR AIR QUALITY IN PASSIVE HOUSES. Ryan Militello-Hourigan, PE Shelly Miller, PhD

THE IMPACTS OF HUMAN ACTIVITIES ON INDOOR AIR QUALITY IN PASSIVE HOUSES. Ryan Militello-Hourigan, PE Shelly Miller, PhD THE IMPACTS OF HUMAN ACTIVITIES ON INDOOR AIR QUALITY IN PASSIVE HOUSES Ryan Militello-Hourigan, PE Shelly Miller, PhD PERSONAL BACKGROUND Ryan Militello-Hourigan, PE (CA) Graduate Researcher Previously,

More information

Air STANDARD. FOR COMMERCIAL INTERIORS v2.0. RESET Air STANDARD for Commercial Interiors v2.0. Copyright 2018 RESET

Air STANDARD. FOR COMMERCIAL INTERIORS v2.0. RESET Air STANDARD for Commercial Interiors v2.0. Copyright 2018 RESET Air STANDARD FOR COMMERCIAL INTERIORS v2.0 Table of Contents 2.2.0 Preface 2.2. Certification Approach 2.2.2 Indoor Air Quality Performance Targets 2.2.3 Data Analysis Algorithm 2.2.4 Data Provider Requirements

More information

AUSTRIAN RISK ASSESSMENT CONCEPT FOR INDOOR AIR CHEMICALS. istockphoto.com/bea

AUSTRIAN RISK ASSESSMENT CONCEPT FOR INDOOR AIR CHEMICALS. istockphoto.com/bea AUSTRIAN RISK ASSESSMENT CONCEPT FOR INDOOR AIR CHEMICALS istockphoto.com/bea OVERVIEW The Austrian Working Group on Indoor Air Mission & Members Indoor Air Guidance Risk Assessment Concept Other Activites

More information

Ventilation and Indoor Air Quality in Schools Guidance Report Building Research Technical Report 20/2005

Ventilation and Indoor Air Quality in Schools Guidance Report Building Research Technical Report 20/2005 Ventilation and Indoor Air Quality in Schools Guidance Report 202825 Building Research Technical Report 20/2005 March 2006 Ventilation and Indoor Air Quality in Schools Guidance Report 202825 Building

More information

THE EFFECT OF DUCT CLEANING ON INDOOR AIR QUALITY IN OFFICE BUILDINGS

THE EFFECT OF DUCT CLEANING ON INDOOR AIR QUALITY IN OFFICE BUILDINGS THE EFFECT OF DUCT CLEANING ON INDOOR AIR QUALITY IN OFFICE BUILDINGS S Kolari 1*, M Luoma 1, M Ikäheimo 2 and P Pasanen 2 1 VTT Technical Research Centre of Finland, Espoo, Finland 2 University of Kuopio,

More information

Comfortable and Healthy Indoor Climate EEN-E4001

Comfortable and Healthy Indoor Climate EEN-E4001 Comfortable and Healthy Indoor Climate EEN-E4001 Lecture 3: Indoor Air Quality Risto Kosonen Aalto University, Espoo, Finland Presentation outline Factors affecting indoor air quality Indoor air pollutants

More information

Indoor Air Quality Assessment Morell Consolidated School Morell, PEI

Indoor Air Quality Assessment Morell Consolidated School Morell, PEI Project No. 14602 Indoor Air Quality Assessment Morell Consolidated School Morell, PEI Prepared for: PEI Dept. Transportation & Infrastructure Renewal P.O. Box 2000 Charlottetown, PE C1A 7N7 Attention:

More information

An Introduction to Radon

An Introduction to Radon An Introduction to Radon Kristian James MPH CEnvH Principal Environmental Public Health Specialist Public Health Wales Specialist content provided by the Radon Group - Programmes Team, PHE Centre for Radiation,

More information

VENTILATION REQUIREMENTS IN A RETAIL STORE

VENTILATION REQUIREMENTS IN A RETAIL STORE - VENTILATION REQUIREMENTS IN A RETAIL STORE D.T. Grimsrud, B.B. Bridges, N.G. Carlson, D.E. Hadlich University of Minnesot~ USA ABSTRACT This field study was organized to determine the ventilation required

More information

TITLE: POLICY ON INDOOR AIR QUALITY IN BUILDINGS. July 14, 2017 Material Resources Department Material Resources Department ROADMAP

TITLE: POLICY ON INDOOR AIR QUALITY IN BUILDINGS. July 14, 2017 Material Resources Department Material Resources Department ROADMAP ID CODE POL17-043 TITLE: POLICY ON INDOOR AIR QUALITY IN BUILDINGS EFFECTIVE DATE APPROVAL REQUIRED RESPONSIBILITY FOR FOLLOW- UP July 14, 2017 Material Resources Department Material Resources Department

More information

VENTILATION RATES AND IAQ IN EUROPEAN STANDARDS AND NATIONAL REGULATIONS

VENTILATION RATES AND IAQ IN EUROPEAN STANDARDS AND NATIONAL REGULATIONS VENTILATION RATES AND IAQ IN EUPEAN STANDARDS AND NATIONAL REGULATIONS Nejc Brelih *1, Olli Seppänen 1 1 REHVA Federation of European heating, ventilation and air conditioning associations Rue Washington,

More information

Web Seminar. Indoor Air Quality. Indoor Air Quality and Air Cleaning 19 November Peter DYMENT Camfil Ltd

Web Seminar. Indoor Air Quality. Indoor Air Quality and Air Cleaning 19 November Peter DYMENT Camfil Ltd Indoor Air Quality Indoor Air Quality and Air Cleaning 19 November 2013 Peter DYMENT Camfil Ltd Indoor Air Quality Indoor Air Quality perception is different for each individual Clean air of the correct

More information

THE REVISION OF STANDARD 62: WHAT A DIFFERENCE A DECADE MAKES

THE REVISION OF STANDARD 62: WHAT A DIFFERENCE A DECADE MAKES THE REVISION OF STANDARD 62: WHAT A DIFFERENCE A DECADE MAKES A Persily * National Institute of Standards and Technology, Gaithersburg, MD, USA ABSTRACT The American Society of Heating, Refrigerating and

More information

Indoor Air Quality Program

Indoor Air Quality Program Indoor Air Quality Program Table of Contents I. Program Goals and Objectives... 2 II. Scope and Application... 2 III. Definitions... 2 IV. Responsibilities... 2 V. Reporting Procedures... 3 VI. Investigation

More information

Indoor air quality and ventilation

Indoor air quality and ventilation Indoor air quality and ventilation requirements Guangyu Cao (guangyu.cao@ntnu.no) Department of Energy and Process Engineering, NTNU (November, 10, 2016, Hainan, China) Have you used e-clicker or any audience

More information

TEXAS FACILITIES COMMISSION Edit Date: 4/13/2012 ARCHITECTURAL/ENGINEERING GUIDELINES

TEXAS FACILITIES COMMISSION Edit Date: 4/13/2012 ARCHITECTURAL/ENGINEERING GUIDELINES General The following guidelines must be met by both the Architect/Engineer (A/E) consultant and the contractor to assure indoor air quality of the building being provided. At the direction of the Project

More information

How We Obtained LEED Certification pertaining to the Indoor Environmental Quality Category. Ron Fields, CAFS, NCT General Dynamics C4 Systems

How We Obtained LEED Certification pertaining to the Indoor Environmental Quality Category. Ron Fields, CAFS, NCT General Dynamics C4 Systems How We Obtained LEED Certification pertaining to the Indoor Environmental Quality Category Ron Fields, CAFS, NCT General Dynamics C4 Systems Outline What is LEED EB? GD LEED Costs and savings IEQ Prerequisites

More information

AirRenew Gypsum Board Products - Frequently Asked Questions

AirRenew Gypsum Board Products - Frequently Asked Questions AirRenew Gypsum Board Products - Frequently Asked Questions What is AirRenew? AirRenew is a family of innovative gypsum board products that helps clean the air and improve indoor air quality. The gypsum

More information

A. The project is intended to achieve LEED Certification at the Silver Level per the U.S. Green Building Council LEED for Schools 2007 rating system.

A. The project is intended to achieve LEED Certification at the Silver Level per the U.S. Green Building Council LEED for Schools 2007 rating system. SECTION 23 01 01 HVAC LEED REQUIREMENTS PART 1 -GENERAL 1.1 WORK INCLUDES A. Compliance with LEED project requirements. B. Coordination of LEED construction phase activities. C. Data gathering of construction

More information

LATEST DEVELOPMENTS IN HEALTH CANADA'S RESIDENTIAL INDOOR AIR QUALITY GUIDELINES

LATEST DEVELOPMENTS IN HEALTH CANADA'S RESIDENTIAL INDOOR AIR QUALITY GUIDELINES Topic: B11. Policy, codes and guidelines LATEST DEVELOPMENTS IN HEALTH CANADA'S RESIDENTIAL INDOOR AIR QUALITY GUIDELINES Annie St-Amand 1,*, Marie-Ève Héroux 1, Brian Giles 1, Deborah Schoen 1 1 Air Quality

More information

Indoor Air Quality Commissioning of a New Office Building. Synopsis. About the Authors

Indoor Air Quality Commissioning of a New Office Building. Synopsis. About the Authors Indoor Air Quality Commissioning of a New Office Building W Stuart Dols, Andrew K Persily, and Steven J Nabhger * National Institute of Standards and Technology (NIS~ Building and Fire Research Laboratory

More information

BREATHE A LITTLE EASIER WITH TSI

BREATHE A LITTLE EASIER WITH TSI BREATHE A LITTLE EASIER WITH TSI PROFESSIONAL MEASUREMENT SOLUTIONS THAT HELP YOU SAVE ENERGY, INCREASE OCCUPANT COMFORT AND ASSURE A HEALTHY ENVIRONMENT Indoor air quality (IAQ) is a growing concern.

More information

Measurement Procedures for Gaseous Contaminants in Commercial Buildings

Measurement Procedures for Gaseous Contaminants in Commercial Buildings ASHRAE Guideline 27P Public Review Draft Measurement Procedures for Gaseous Contaminants in Commercial Buildings Third Public Review (July 2016) (Complete Draft for Full Review) This draft has been recommended

More information

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS INDOOR AIR QUALITY INSTRUMENTS UNDERSTANDING, ACCELERATED BREATHE A LITTLE EASIER WITH TSI Indoor air quality is a growing concern. With the increasing

More information

Washington State Department of Health Division of Environmental Health

Washington State Department of Health Division of Environmental Health Washington State Department of Health Division of Environmental Health School Indoor Air Quality Monitoring Project Washington Resource Conservation Manager (RCM) Meeting July 19, 2007 Washington Middle

More information

January 20, Mr. Marty Foutch Facilities Director Bixby Public Schools 109 N. Armstrong Bixby, OK 74008

January 20, Mr. Marty Foutch Facilities Director Bixby Public Schools 109 N. Armstrong Bixby, OK 74008 January 0, 0 Mr. Marty Foutch Facilities Director Bixby Public Schools 09 N. Armstrong Bixby, OK 0 RE: Bixby th, th, and 6 th Elementary Indoor Air Quality CO and % Liberty OHM File Number 0-09 Dear Mr.

More information

Technology Company. About Technology Company. The Challenge. Research Headquarters Building. 1. enverid Case Study

Technology Company. About Technology Company. The Challenge. Research Headquarters Building.  1. enverid Case Study enverid Case Study Technology Company Research Headquarters Building About Technology Company This U.S.-based multinational corporation, and member of the Fortune 25 list, is dedicated to making high quality

More information

Indoor Air Quality Assessments

Indoor Air Quality Assessments HS13_IAQ_SOP 1. Purpose and Requirements Symptoms arising from poor indoor air quality often mimic those symptoms commonly associated with a cold, flu or allergies. These symptoms may include upper respiratory

More information

Air pollution is caused by high concentrations of gases and particles emitted form combustion sources (vehicles, power plants, industries)

Air pollution is caused by high concentrations of gases and particles emitted form combustion sources (vehicles, power plants, industries) AIR POLLUTION Clean Air Act & Criteria Pollutants 7.1-7.5 Motor Vehicle Emissions: 7.8 Indoor Air and Box Models: 7.12 Air Pollution Meteorology: 7.10 Gaussian Plume Modeling: 7.11 1 Air pollution is caused

More information

OSHA Act of 1970 Section 5(a)(1) Duties, as may be amended.

OSHA Act of 1970 Section 5(a)(1) Duties, as may be amended. TO: FROM: PREPARED BY: SUBJECT: PPM #: ALL COUNTY PERSONNEL VERDENIA C. BAKER COUNTY ADMINISTRATOR RISK MANAGEMENT INDOOR AIR QUALITY (IAQ) PROGRAM CW-L-037 ====================================================================

More information

Assessment of Mold Resistance Performance for Building Materials in Humid Subtropical Zone

Assessment of Mold Resistance Performance for Building Materials in Humid Subtropical Zone Assessment of Mold Resistance Performance for Building Materials in Humid Subtropical Zone (1)Shih-Chi Lo (2)Jyh-Tyng Yau (1)losc@abri.gov.tw (2)jyhtyng@abri.gov.tw Architecture and Building Research Institute,

More information

Civil Engineering Research Exchange Symposium Session I STRUCTURES AND MATERIALS

Civil Engineering Research Exchange Symposium Session I STRUCTURES AND MATERIALS Session I STRUCTURES AND MATERIALS 1 Indoor Air quality and human activities in buildings Perera T.M. 1,*, Jayasinghe C. 2, Perera S.A.S 3, Rajapaksa S.W. 4 Abstract People spend most of their time indoors

More information

Period of Time Contaminant is Measured. 1 - hour average 8 - hour average 20 (17) Guideline Micrograms per cubic metre of air 1 - hour average 4.

Period of Time Contaminant is Measured. 1 - hour average 8 - hour average 20 (17) Guideline Micrograms per cubic metre of air 1 - hour average 4. Units of is Ammonia Milligrams per cubic metre (parts 1.4 (2.0) 7 Arsenic Micrograms per cubic metre of air 0.3 20 Cadmium Micrograms per cubic metre of air 2 20 Carbon Monoxide Objective Milligrams per

More information

On The Quest For Indices Defining Indoor Air Quality. What Is A Reasonable Approach? Pawel Wargocki

On The Quest For Indices Defining Indoor Air Quality. What Is A Reasonable Approach? Pawel Wargocki On The Quest For Indices Defining Indoor Air Quality. What Is A Reasonable Approach? Pawel Wargocki International Centre for Indoor Environment and Energy Department of Civil Engineering Technical University

More information

Classification of Indoor Climate, Construction, and Finishing Materials

Classification of Indoor Climate, Construction, and Finishing Materials Classification of Indoor Climate, Construction, and Finishing Materials 0. Seppiinen Department of Mechanical Engineering, Helsinki University of Technology, Espoo, Finland Abstract Good indoor climate

More information

Notes on Indoor Air Quality

Notes on Indoor Air Quality Notes on Indoor Air Quality Indoor Air Quality (IAQ) a Health and Safety Concern? Indoor air quality has become an important occupational health and safety concern. Energy conservation measures instituted

More information

JONIX minimate NON THERMAL PLASMA TECHNOLOGY

JONIX minimate NON THERMAL PLASMA TECHNOLOGY Food Technology JONIX minimate NON THERMAL PLASMA TECHNOLOGY MOBILE DEVICE FOR INDOOR AIR PURIFICATION AND DECONTAMINATION MADE IN ITALY JONIX minimate Wheeled version JONIX minimate Wall mounted version

More information

Dr. Fabrice Didier Group Director - Marketing

Dr. Fabrice Didier Group Director - Marketing Dr. Fabrice Didier Group Director - Marketing AGENDA 1. RESIDENTIAL AND NON RESIDENTIAL BUILDINGS: TOWARDS DIVERGENT REQUIREMENTS? 2. WHY COMFORT AND SUSTAINABILITY MATTER EVERYWHERE 3. HOW TO PUT THIS

More information

NABERS Indoor Environment

NABERS Indoor Environment NABERS Indoor Environment For the next generation of sustainability leaders A guide to the NABERS Indoor Environment rating tool for building owners, managers & tenants [November 2015] About this Guide

More information

INDOOR AIR QUALITY AND MATERIAL EMISSIONS IN NEW BUILDINGS

INDOOR AIR QUALITY AND MATERIAL EMISSIONS IN NEW BUILDINGS INDOOR AIR QUALITY AND MATERIAL EMISSIONS IN NEW BUILDINGS H Järnström * and K Saarela VTT Building and Transport, Service Centre, P.O. Box. 141, FIN-244 VTT, Finland ABSTRACT A research project was established

More information

Radon Levels and Indoor Air Quality in Northern Ireland Certified Passive House Buildings

Radon Levels and Indoor Air Quality in Northern Ireland Certified Passive House Buildings Radon Levels and Indoor Air Quality in Northern Ireland Certified Passive House Buildings CIBSE Technical Symposium London 2018 Thursday 12th Friday 13th April Introduction CREST since 2013 Passive House

More information

Coggins, Marie; Broderick, Aine; Byrne, Miriam. https://doi.org/ /s8f92c

Coggins, Marie; Broderick, Aine; Byrne, Miriam. https://doi.org/ /s8f92c Provided by the author(s) and NUI Galway in accordance with publisher policies. Please cite the published version when available. Title Indoor air quality and thermal comfort in Irish retrofitted energy

More information

Technical Guide Towards Energy Smart HOTEL. Energy Sustainability Unit. Department of Building National University of Singapore.

Technical Guide Towards Energy Smart HOTEL. Energy Sustainability Unit. Department of Building National University of Singapore. Technical Guide Towards Energy Smart HOTEL Energy Sustainability Unit Department of Building National University of Singapore Sponsored by Table of Contents 1 Introduction 1.1 Aim 1.2 Overview of Energy

More information

FOLLOW-UP TOTAL VOLATILE ORGANIC COMPOUND SAMPLING SIR WILFRED GRENFELL COLLEGE CORNER BROOK, NL. Prepared for:

FOLLOW-UP TOTAL VOLATILE ORGANIC COMPOUND SAMPLING SIR WILFRED GRENFELL COLLEGE CORNER BROOK, NL. Prepared for: FOLLOW-UP TOTAL VOLATILE ORGANIC COMPOUND SAMPLING SIR WILFRED GRENFELL COLLEGE CORNER BROOK, NL Prepared for: SIR WILFRED GRENFELL COLLEGE 1 UNIVERSITY DRIVE CORNER BROOK, NL A2H 6P9 ATTENTION: MR. DAVID

More information

According to our research and study most occupant complaints relating to IAQ are attributable to the following factors:

According to our research and study most occupant complaints relating to IAQ are attributable to the following factors: Report pertaining to the Duct Cleaning of ICU! &ICU2 at Hospital 5 th & 6 th Floor. The IAQ Report documents by Photograph (at random) photo shots of the various ducting systems & AHU Systems for work

More information

U.S. INDOOR AIR QUALITY MARKET

U.S. INDOOR AIR QUALITY MARKET U.S. INDOOR AIR QUALITY MARKET ENV003D July 2012 Andrew McWilliams Project Analyst ISBN: 0-89336-058-9 BCC Research 49 Walnut Park, Building 2 Wellesley, MA 02481 Phone: 866-285-7215 (sales) Web Address:

More information

Ball State Architecture ENVIRONMENTAL SYSTEMS 2 Grondzik 1 Indoor Air Quality

Ball State Architecture ENVIRONMENTAL SYSTEMS 2 Grondzik 1 Indoor Air Quality INDOOR AIR QUALITY OPR IAQ: one of the key outcomes along with thermal comfort of a climate control system www.todaysfacilitymanager.com/ Ball State Architecture ENVIRONMENTAL SYSTEMS 2 Grondzik 1 Indoor

More information

INDOOR AIR QUALITY ASSESSMENT. Department of Developmental Services & Department of Mental Health Service Center 35 Nagog Park Acton, Massachusetts

INDOOR AIR QUALITY ASSESSMENT. Department of Developmental Services & Department of Mental Health Service Center 35 Nagog Park Acton, Massachusetts INDOOR AIR QUALITY ASSESSMENT Department of Developmental Services & Department of Mental Health Service Center 35 Nagog Park Acton, Massachusetts Prepared by: Massachusetts Department of Public Health

More information

Indoor Air Quality Monthly Testing Services, Corcoran Gallery of Art, th Street NW, Washington, DC December 2017

Indoor Air Quality Monthly Testing Services, Corcoran Gallery of Art, th Street NW, Washington, DC December 2017 Mr. Dan Janniello, LEED AP The George Washington University 2025 F Street NW, Suite 200 Washington, DC 20052 djanniel@email.gwu.edu ECS Project No. 47:2199-A Reference: Indoor Air Quality Monthly Testing

More information

Health and Environmental Aspects Linked to Home Ventilation (HEALTH-V Study) -Preliminary data

Health and Environmental Aspects Linked to Home Ventilation (HEALTH-V Study) -Preliminary data Health and Environmental Aspects Linked to Home Ventilation (HEALTH-V Study) -Preliminary data Dave Jacobs 1 2, Salvatore Cali, 1 Loreen Targos 1, Paul Francisco 3, William B. Rose, Zachary Merrin 3, Steve

More information

Indoor Air Quality and Rodent Droppings Assessment

Indoor Air Quality and Rodent Droppings Assessment Indoor Air Quality and Rodent Droppings Assessment Pacific Highway Border Crossing, Traffic and Commercial Operations Building 26 176th Street, Surrey, BC April 28, 2016 Prepared for: Public Works and

More information

SECTION SUSTAINABILITY CERTIFICATION REQUIREMENTS LEED NC V3

SECTION SUSTAINABILITY CERTIFICATION REQUIREMENTS LEED NC V3 PART 1 - GENERAL 1.1 DESCRIPTION SECTION 01 81 13.01 SUSTAINABILITY CERTIFICATION REQUIREMENTS LEED NC V3 A. This section describes requirements and procedures which are additive to and compatible with

More information

BIU Büro für integrierten Umweltschutz

BIU Büro für integrierten Umweltschutz Eurofins VOC Seminar 2015 for Manufacturers at Frankfurt Airport 28 th October 2015 Eco-friendly and low emitting building products for sustainable and green buildings certified by LEED, BREEAM & DGNB

More information

University of Rochester Environmental Health & Safety Indoor Air Quality Program March 23, 2005

University of Rochester Environmental Health & Safety Indoor Air Quality Program March 23, 2005 University of Rochester Environmental Health & Safety Indoor Air Quality Program March 23, 2005 1. Purpose: The purpose of this program is to inform the University community about indoor air quality (IAQ).

More information

ANALYSIS OF INDOOR AIR QUALITY IN HIGH-SPEED TRAIN PASSENGER CABIN IN KOREA

ANALYSIS OF INDOOR AIR QUALITY IN HIGH-SPEED TRAIN PASSENGER CABIN IN KOREA ANALYSIS OF INDOOR AIR QUALITY IN HIGH-SPEED TRAIN PASSENGER CABIN IN KOREA Youngmin Cho 1, Soon-Bark Kwon 1, and Duck-Shin Park 1 1 Environment & Fire Control Research Team, Korea Railroad Research Institute,

More information

Current Status of Research Activity for Industrial Ventilation and Future Problem in Japan

Current Status of Research Activity for Industrial Ventilation and Future Problem in Japan Current Status of Research Activity for Industrial Ventilation and Future Problem in Japan Nobuyuki Kobayashi a, Kazuhide Ito b a Dr. Eng., Professor, Tokyo Polytechnic University, Japan b Dr. Eng., Assistant

More information

Central Michigan University Indoor Air Quality Response Procedure

Central Michigan University Indoor Air Quality Response Procedure Central Michigan University Indoor Air Quality Response Procedure This procedure has been developed for the purpose of preventing or reducing the incidence of indoor air quality concerns by providing an