EESTI AKREDITEERIMISKESKUS ESTONIAN ACCREDITATION CENTRE
|
|
- Dorthy Bryan
- 5 years ago
- Views:
Transcription
1 1/9 1. Akrediteerimisulatus on: Accreditation scope is: EESTI AKREDITEERIMISKESKUS ESTONIAN ACCREDITATION CENTRE LISA 7 OÜ Eesti Keskkonnauuringute Keskuse akrediteerimistunnistusele nr L008 ANNEX 7 to the accreditation certificate No. L008 of Estonian Environmental Research Centre LLC 1.1 Keskkonnaanalüüsid (Jõhvi) Environmental analyses Analysed parameters 7.1 Ammooniumioon ( NH4 + ) Ammonium ion 7.2 Nitraatioon (NO3 - ) Nitrate ion 7.3 Nitritioon (NO2 - ) Nitrite ion 7.4 Sulfaatioon (SO4 2- ) Sulfate ion 7.5 Üldfosfor (Püld) Total phosphorus (Ptot) 7.6 Ortofosfaatioon (PO4 3- ) Ortophosphate ion 7.7 Hägusus Turbidity Fotomeetria Photometry Põhja-, pinna- ja joogivesi Ground, surface and drinking water SFS 3032 ISO ISO 6777 AOAC EVS-EN ISO 6878 Sec. 7 EVS-EN ISO 6878 Sec. 4 EVS-EN ISO ,01 mg/l 0,09 mg/l 0,007 mg/l 5 mg/l 0,01 mg/l 0,015 mg/l 0,5 NHÜ
2 2/9 Nr Määratavad näitajad Analysed parameters 7.8 Üldlämmastik (Nüld) (oksüdeerimine peroksodisulfaadiga) Total nitrogen (Ntot) (digestion with peroxodisulfate) 7.9 Üldraud (Fe); kahevalentne raud (Fe 2+ ) Total iron and iron (II) 7.10 Kuuevalentne kroom (Cr 6+ ) Chromium (Cr 6+ ) 7.11 Lahustunud silikaadid Dissolved silicate 7.12 Klorofüll-a Chlorophyll-a Pinna-, põhja ja joogivesi Surface ground and drinking water Pinna- ja merevesi Surface and sea water EVS - EN ISO ,04 mg/l ISO 6332 SM 3500-Cr B, APHA 2011 Method of Seawater Analysis, K.Grasshoff, 1999 ISO ,04 mg/l 0,00 0,02 mgsi/l 1,5 µg/l 7.13 Värvus Colour 7.14 Lõhnaläve ja maitseläve indeks Threshold odour number and threshold flavour number 7.15 Kuivjääk Dry residue 7.16 Hõljuvaine Suspended solids 7.17 Naftasaadused ja rasvad Oil products and fats Füüsikalis-keemilised katsed Physical - chemical tests Põhja-, pinna- ja joogivesi EVS-EN ISO 7887 Ground, surface and drinking water sec D Joogivesi EVS-EN 1622 Drinking water Gravimeetria Gravimetric determination SFS 3008 EVS-EN 872 EPA Method mgpt/l
3 3/9 Nr Määratavad näitajad Analysed parameters 7.18 Kaltsiumioon (Ca 2+ ) Calcium ion Tiitrimeetria Titrimetric determination ISO Üldkaredus Total hardness ISO ,1 mg-ekv/l 7.20 Ammooniumioon (NH4 + ) Ammonium ion Heit-, reo- ja pinnavesi Waste and surface water 7.21 Leelisus Alkalinity 7.22 Keemiline (dikromaatne) hapnikutarve (KHTCr) Chemical oxygen demand(codcr) 7.23 Keemiline (permanganaatne) Põhja-, pinna- ja joogivesi hapnikutarve e. oksüdeeritavus Ground, surface and drinking water (KHTMn) Chemical oxygen demand (CODMn) 7.24 Üldlämmastik (Nüld) (modifitseeritud Kjeldahl meetod) Total nitrogen (Ntot) ( modified Kjeldahl method) 7.25 Kloriid ioon (Cl - ) Chloride ion 7.26 ph ph 7.27 Elektrijuhtivus Electrical conductivity SFS 5505 EVS - EN ISO ISO 6060 SFS 3036 SFS 5505 SM 4500-Cl D, APHA 2011 Elektrokeemilised määramised Electrochemical determinations ISO EVS-EN mg/l 0,1 mg-ekv/l 25 mgo2/l 1 mgo/l 1 mg/l 3,5 mg/l (1,0 13,0) ph ühikut 1,0 µs/cm
4 4/9 Nr Määratavad näitajad Analysed parameters 7.28 Biokeemiline hapnikutarve (BHTn) Biochemical oxygen demand (BODn) 7.29 Fenoolsed ühendid Phenolic compounds 7.30 Proovivõtt Sampling Põhja- ja pinnavesi EVS-EN Ground and surface water ISO EVS-EN ISO Vedelikkromatograafia Liquid chromatography Reovesi STJnrU12C Proovivõtt Sampling Vesi, reoveesetted, setted Water, sewage sludge, sediments 0,7 mgo2/l 3 mgo2/l 34 µg/l (1-aluselised) 14 µg/l (2-aluselised) ISO 5667 (1;3;4;5;6,9; 10;11;12;13;15;19) STJnrP7 Elektrokeemilised määramised mõõtmised proovivõtul Electrochemical determinations in-situ measurements 7.31 ph ph Vesi Water 7.32 Elektrijuhtivus Vesi Electrical conductivity Water 7.33 Lahustunud hapnik Vesi Dissolved oxygen Water 1.2 Õhu ja gaaside analüüsid, sisekliima parameetrite mõõtmine (Jõhvi) Air and gas analyses, measurement of indoor climate parameters Analysable parameters 7.34 Vääveldioksiid (SO2) Sulfur dioxide 7.35 Lämmastikdioksiid ( NO2) Nitrogen dioxide Fotomeetria Photometry ISO EVS-EN EVS-EN ISO 5814 STJnrA7 STJnrA1 (1,0 13,0) ph ühikut 1,0 µs/cm (0,1 20) mg/l 0,01 mg/m 3 0,01 mg/m 3
5 5/9 Analysable parameters 0,001 mg/m Väävelvesinik (H2S) Hydrogen sulfide STJnrA Fenoolid STJnrA3 0,002 mg/m 3 Phenols 7.38 Ammoniaak (NH3) STJnrA4 0,01 mg/m 3 Ammonia 7.39 Formaldehüüdid STJnrA5 0,005 mg/m 3 Formaldehyde 7.40 Osakeste fraktsioonid (PM1, PM Välis- ja siseõhk STJnrÕ138 1,0 µg/m mg/m 3 2,5, PM10) and indoor air Fractions of particulate matter (PM1, PM 2,5, PM10) Gravimeetria Gravimetric determination 7.41 Tolm Välis- ja siseõhk STJnrÕ9 0,2 mg/m 3 10 mg/ m 3 Dust Ambient and indoor air ASTM D Tolmu osakeste kontsentratsioon Emissioonigaasid STJnrÕ104 0,005 g/m 3 10 g/m 3 (PM sum) Emission gases ISO 9096 Dust (PM-sum) Elektrokeemilised määramised Electrochemical determinations 7.43 Süsinikmonooksiid (CO), Siseõhk STJnrÕ ppm väävelvesinik (H2S) Indoor air ppm Hapnik (O2) 1 25 mahu % Metaan (CH4) LEL % CO, H2S, O2 and CH Prügilagaasid (CH 4, CO 2, H 2S, CO, O 2) (automaatanalüsaatoriga GA 5000) Landfill gases (CH 4 CO 2 H 2S, CO, O 2) (by automatic analyzer GA 5000) Emissioonigaasid Emission gases STJnrÕ119 ( ) % (CH4) ( ) % (CO2) ( ) % (O2) ( ) ppm (CO) ( ) ppm (H2S)
6 6/9 Analysable parameters 7.45 Suitsugaasid (SO2, NO, NO2, CO, CO2 ja O2 ) (Testo 350 gaasianalüsaator) Flue gases (SO2, NO, NO2, CO, CO2 and O2) (Testo 350 gases analyser) 7.46 Väävelvesinik (H2S) (kullakihiline absorbeerumise meetodil, JEROM 631X) Sulphur hydrogen (H 2S) (by gold film sensor, JEROM 631X) 7.47 Gaaside liikumise kiirus. Mahtkiirus Velocity and flow rate 7.48 Temperatuur, suhteline niiskus ja õhu liikumiskiirus Temperature, relative humidity and velocity Müra Noise 7.50 Valgustatus Illuminance 7.51 Proovivõtt Sampling 7.52 Proovivõtt Sampling Emissioonigaasid Emission gases EVS-EN STJnrÕ131 Kulonomeetria Culonometry STJnrÕ111 Termoanemomeetria Termoanemometric determination Gaasivood STJnrÕ12 Gas stream Füüsikalised mõõtmised Physical measurements Sisekliima STJnrF2 Indoor climate EVS-EN ISO EVS-EN ISO 7726 Sisekliima Indoor climate Sisekliima Indoor climate Proovivõtt Sampling ja siseõhk and indoor air Emissioonigaasid Emission gases STJnrF1 EVS ISO STJnrF3 EVS 891 STJnrÕ112 STJnrÕ123 EVS-EN ( ) ppm (SO2) ( ) ppm (NO) ( ) ppm (NO2) ( ) ppm (CO) (0, ) % (O2) (0, ) % (CO2) (0, ) ppm (0,1 20) m/s 1 (m 3 /s) ( 0,1 50) C (10 95) % ( 0,1 20 ) m/s ( ) db ( ) 1ux
7 7/9 1.3 Keskkonnaanalüüsid (Kohtla-Järve) Environmental analyses Analysable parameters 7.53 Nitiritioon (NO2 - ) Nitrite ion 7.54 Nitraatioon (NO3 - ) Nitrate ion 7.55 Üldfosfor (Püld) Total phosphorus (Ptot) 7.56 Sulfaatioon (SO4 2- ) Sulfate ion 7.57 Fenoolindeks Phenol index 7.58 Kahealuselised fenoolid Phenols 7.59 Formaldehüüdid Formaldehyde 7.60 Õlid Oils 7.61 Hõljuvaine Suspended solids 7.62 Kuivjääk Dry residue Kuivaine, niiskus Dry matter, moisture Põletusjääk, orgaaniline aine Ignition residue, organic matter Fotomeetria Photometry ISO 6777 ISO EVS-EN ISO 6878, sec 7 AOAC ISO 6439 STJnrV12 STJnrV24 STJnrV31 Gravimeetria Gravimetric determination EVS-EN 872 SFS 3008 Muda, reoveesetted SFS 3008 Mud, sewage sludge EVS-EN 12880, SFS 3008 muda, reoveesetted EVS-EN 12879, mud, sewage sludge 0,0 0,01 mg/l 0,04 mg/l 15 mg/l 0,1 mg/l 0,1 mg/l 0,08 mg/l 3,5 mg/l 4%
8 8/9 Nr Määratavad näitajad Analysable parameters 7.63 Naftasaadused ja rasvad Oil products and fats 7.64 Ammooniumioon (NH4 + ) Ammonium ion 7.65 Üldlämmastik (Nüld) (modifitseeritud Kjeldahli meetod) Total nitrogen (Ntot) (modified Kjeldahl method) 7.66 Sulfiid (S 2- ) Sulfide 7.67 Kloriid (Cl - ) (Mohr'i meetod) Chloride 7.68 Keemiline (dikromaatne) hapnikutarve (KHTCr) Chemical oxygen demand (CODCr) 7.69 ph ph 7.70 Biokeemiline hapnikutarve (BHTn) Biochemical oxygen demand (BODn) 7.71 Pindaktiivsed ained Surfactant content EPA Method 1664 Tiitrimeetria Titrimetric determination SFS 5505 SFS 5505 SM 4500 S 2 F, APHA 2011 ISO 9297 ISO 6060 Elektrokeemilised määramised Electrochemical determinations ISO ISO Muud Others ISO ,4 mg/l 1 mg/l 0,4 mg/l 8 mg/l 30 mgo2/l (1,0 13,0) ph ühikut 3 mgo2/l 0,1 mg/l
9 9/9 2. Katsetamist teostav struktuuriüksus: Virumaa osakond Part of legal entity that provides testing: Virumaa Department Aadressid: Pargi 15, Jõhvi; Uus-Tehase 3, Kohtla Järve Addresses: 3. Labor on akrediteeritud standardi EVS-EN ISO/IEC 17025:2006 nõuete suhtes Laboratory is accredited against the requirements of standard EVS-EN ISO/IEC 17025:2006 Märkus: käesolev lisa asendab välja antud lisa seoses akrediteerimisulatuse kitsendamisega võtmisega. Note: this annex replaces annex issued on due to reduction in the accreditation scope. Kristiina Saarniit Maia Valm EAK juhataja Peaassessor Director of EAK Lead Assessor Tallinnas,
Joogi-, põhja-, pinna-, mere-, heitja reovesi, sademed Drinking, ground, surface and seawater, effluent, waste water, precipitation
LISA 1 OÜ Eesti Keskkonnauuringute Keskuse akrediteerimistunnistusele L008 of Estonian Environmental Research Centre LLC 1. Akrediteerimisulatus on: Accreditation scope is: 1.1. Keskkonna analüüsid Environmental
More informationPrakruti Environmental Engineers (Environmental Laboratory), 1, Utkanth Society, B/H Alkapuri Club, Alkapuri, Vadodara, Gujarat
Prakruti Environmental Engineers (Environmental ), Last Amended on - Page 1 of 7 I. WATER 1. Water (Ground Water/ Surface Water/ Drinking Water/ Treated Water) ph APHA 4500-H + B, Temperature APHA 2550
More informationLISA G.W.Berg OÜ akrediteerimistunnistusele nr K014 ANNEX to the accreditation certificate No K014 of G.W.Berg Ltd
LISA G.W.Berg OÜ akrediteerimistunnistusele nr K014 ANNEX to the accreditation certificate K014 of G.W.Berg Ltd 1. Akrediteerimisulatus on: Accreditation scope is: Labori asukoht: Laki tn 25, Tallinn Location
More informationKKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana
Last Amended on - Page 1 of 7 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Monitoring RSPM ( PM 10) IS 5182 (Part 23): 2006 (RA ) 5 µg/m 3 to 750 µg/m 3 PM 2.5 SOP 11 dated 17.11.2014 12.5 µg/m 3 to 500 µg/m
More informationDiscipline Chemical Testing Issue Date Certificate Number T-3553 Valid Until Last Amended on - Page 1 of 9
Last Amended on - Page 1 of 9 I. ORES & MINERALS 1. Iron Ore Total Iron IS 1493: 1981 (RA 2006) 10 % to 70 % Silicon IS 1493: 1981 (RA 2006) 0.5 % to 25 % Aluminum IS 1493: 1981 (RA 2006) 0.5 % to 20 %
More informationWinmet Technologies Private Limited, Plot No. E-65, Site-IV, UPSIDC, Greater Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date
Last Amended on - Page 1 of 8 I. AIR, GASES & ATMOSPHERE 1. Ambient Air PM 2.5 PM10 (RSPM) WMN/ENV/AIR/03, Issue no. 1 dated 01.10.2013 IS: 5182 (Part -23)-2006, 10 500 µg/m 3 10 1000 µg/m 3 Suspended
More informationENVIPRO Laboratories, 2nd Floor, Sy. No. 63/4, Site No. 5, P&T Layout Road, Ashwath Nagar, Srigandhada Kaval, Sunkadakatte, Bangalore, Karnataka
Certificate Number TC-6325 Page 1 of 5 Range ing / CHEMICAL TESTING I. WATER 1. Surface Water, Ground Water, Industrial Water, Drinking Water, Irrigation Water, Water From Purifiers & Swimming Pool Water
More informationDiscipline Chemical Testing Issue Date Certificate Number T-3790 Valid Until Last Amended on - Page 1 of 5
Last Amended on - Page 1 of 5 AT LABORATORY I. WATER 1. Drinking Water, Colour IS 3025 (Part 4): 1983 (RA 2002) Spectrometer method 2120C Odour IS 3025 (Part 5): 1983 (RA 2002) 2 Hazen units to 500 Hazen
More informationNichrome Testing Laboratory and Research Private Limited, No nd Main, German Hospital Road, Narayanpur, Dharwad, Karnataka
Last Amended on - Page 1 of 9 I. WATER 1. Drinking Water Colour 2120 B 1 to 100 Hazen Units ph 4500 H+, B 3 to 12 Electrical conductivity 2510 B 5 to 10,000 µs/cm Turbidity 2130 B 1 to 100 NTU Chloride
More informationRECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed
Sl Product / Material of test 1 Wastewater Colour, true colour units, 2 Turbidity, NTU 3 Total dissolved solids mg/1, IS-3025 (Part 4) -1983 2005: 2120 /C IS-3025 (Part 10)-1984 2005: 2130/B IS-3025 (Part
More informationSuperintendence Company of India Private Limited, Plot Y-23, Block-EP, Sector-V, Salt Lake City, Kolkata, West Bengal
Last Amended on - Page 1 of 16 I. WATER 1. Drinking Water ph IS 3025 (Part 2): 2004, Colour APHA (22 nd Edition) 2120 B: Turbidity (NTU) IS 3025 (Part 10): 1984 Residual, Free Chlorine IS 3025 Part 26/1986
More informationDiscipline Chemical Testing Issue Date Certificate Number T-3617 Valid Until Last Amended on
Last Amended on 18.01.2016 Page 1 of 8 I. WATER 1. Potable, Domestic and Bore-well Water ph IS 3025 (Part 11): 1983 Electrometric Method Colour IS 3025 (Part 4): 1983 Specific Conductance IS 3025 (Part
More informationBord Na Móna Environmental Ltd trading as ANUA
trading as ANUA Technical Services Analytical Laboratory, Main Street, Newbridge, Co. Kildare Testing Laboratory Registration number: 083T is accredited by the Irish National Board (INAB) to undertake
More informationEnvironment Laboratory, Central Mine Planning & Design Institute Limited, Regional Institute-IV, Kasturba Nagar, Jaripatka, Nagpur, Maharashtra
Last Amended on - Page 1 of 9 I. POLLUTION & ENVIRONMENT 1 Effluent / Waste Water (As per EPA 2000) Ammonical Nitrogen / Free Ammonia IS 3025(Part 34):1988, RA 2009, Nessler s Method 0.02-2.5 mg/l, B.O.D
More informationMadhya Pradesh Waste Management Project Laboratory, Plot No. 104, Industrial Area No. II, Pithampur, Dhar, Madhya Pradesh
Madhya Pradesh Waste Management Project, Certificate Number TC-5022 (in lieu of T-2449) Page 1 of 8 CHEMICAL TESTING I. POLLUTION AND ENVIRONMENT 1. Waste Water (Effluent & Sewage) ph APHA 22nd Edition,
More informationEnvironment Laboratory, Central Mine Planning and Design Institute Limited, Gondwana Place, Kanke Road, Ranchi, Jharkhand
Environment, Central Mine Planning and Design Institute Last Amended on - Page 1 of 9 1. POLLUTION & EFFLUENTS 1. Effluent / Waste Water Ammonical Nitrogen Free Ammonia IS 3025 (Part 34):1988, Nessler
More informationDeep Testing Laboratories, Plot No.- 338, Sector-58, Ballabhgarh, Faridabad, Haryana. Discipline Chemical Testing Issue Date
Last Amended on - Page 1 of 6 I. METALS & ALLOYS 1. Plain Carbon & Low Alloy Steels Carbon IS 228 (Part-1) 1987, RA 2007 0.05% to 2.5% Mn IS 228 (Part-2) 1987, RA 2002 0.1% to 2.5% Si IS 228 (Part-8) 1989,
More informationNexus Test Labs Pvt. Ltd., No. 29, 2 nd Floor, 3 rd Cross, Singaiahnapalya, Mahadevapura, Bangalore, Karnataka
Certificate Number TC-5069 (in lieu of T-3362 & T-3363) Page 1 of 17 Range ing / BIOLOGICAL TESTING I. WATER 1. Drinking Water R.O. Water, Ground Water, Surface Water, Treated Water. 2. Waste Water/ Effluents
More informationGLOBAL TECH. ENVIRO EXPERTS PVT. LTD. (FORMERLY GLOBAL EXPERTS) An ISO-9001:2008 Certified Company
STACK MONITORING RESULT Name of Industry & Address Date of Monitoring 08-11-17 Date of Analysis 12-11-17 Reference No Stk-05/11/17 M/s SHIVA CEMENT LIMITED: Sl. No. Parameters Cement Mill 1 Kiln (Result)
More informationMahabal Enviro Engineers Pvt. Ltd. Pollution monitoring, Engineers & Contractors in Environmental Management
PROPOSED RESIDENTIAL CUM COMMERCIAL PROJECT WITH MCGM PARKING LOT, AT LOWER PAREL, MUMBAI, MAHARASHTRA GROUND WATER ANALYSIS October, 2017 Parameter Units Sample 1 Source Location Date of collection of
More informationSchedule of Accreditation
Schedule of Accreditation Organisation Name TMS Environment Ltd INAB Reg No 150T Contact Name Marian Brady Address 53 Broomhill Drive, Tallaght, Dublin Contact Phone No 01-4626710 Email mbrady@tmsenv.ie
More informationSchedule. Type of Test/ Properties Measured/ Range of Measurement. Biochemical Oxygen Demand (BOD) Calcium as Ca. Chromium, Hexavalent
LABORATORY LOCATION: (PERMANENT LABORATORY) Page: 1 of 12 SPECTRUM LABORATORIES (PENANG) SDN. BHD. 1904 TINGKAT 1, JALAN BUKIT MINYAK TAMAN SRI MANGGA, 14000 BUKIT MERTAJAM SEBERANG PRAI TENGAH PULAU PINANG
More informationAUTOMATED WATER ANALYSIS
APPLICATION NOTE - CFA AUTOMATED WATER ANALYSIS APPLICATIONS OF CONTINUOUS-FLOW ANALYZERS In laboratories around the world, the SEAL Analytical analyzers measure all types of water - quickly, accurately
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELICROM CÍA. LTDA. Cdla. Guayaquil, Mz 21 Calle Primera, Solar 10 Guayaquil, Ecuador 090506 Camilo Moreno Phone: 593 4 2282007 CHEMICAL Valid To: August 31,
More informationWest Virginia Department of Environmental Protection hereby certifies Microbac - Ohio Valley Division
West Virginia Department of Environmental Protection hereby certifies Microbac - Ohio Valley Division to perform analyses for the purpose of determining compliance with the requirements of the state's
More informationHaryana Test House & Consultancy Services, 50-C, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date
Last Amended on 15.09.2014 Page 1 of 12 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Particulate Matter (PM 10 ) IS: 5182 (Part-23) : 2006 (RA2012) 10 to 200 g/m 3 Particulate Matter (PM 2.5 ) Carbon Monoxide
More informationEnvironmental Protection Agency
PO Box 3000, Johnstown Castle Estate, Wexford Testing Laboratory Registration number: 113T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule bearing the
More informationCALA Directory of Laboratories
CALA Directory of Laboratories Membership Number: 2907 Laboratory Name: Avalon Laboratories Inc. Parent Institution: Avalon Laboratories Inc. Address: 85C Bremigens Blvd Paradise NL A1L 4A2 Contact: Ms.
More informationCALA Directory of Laboratories
CALA Directory of Laboratories Membership Number: 4114 Laboratory Name: African Assay Laboratories Ltd (Tanzania)- Environmental Laboratory Parent Institution: Address: Balewa Road Mwanza 255 Contact:
More informationANALYTES available for testing
ANALYTES available for testing codes WS = water supply, drinking water, potable water WP = wastewater, general water quality, ODA OK = Oklahoma DEQ ODA = Oklahoma Department of Agriculture KS = Kansas
More informationChemical characteristics of natural watercourses in the Gurahont Depression
Volume 15(3), 115-122, 2011 JOURNAL of Horticulture, Forestry and Biotechnology Chemical characteristics of natural watercourses in the Gurahont Depression Balaşcău G. D. 1* 1 U.S.A.M.V.B.Timişoara, Faculty
More informationSCOPE OF ACCREDITATION TO ISO GUIDE 34:2009
SCOPE OF ACCREDITATION TO ISO GUIDE 34:2009 SCP SCIENCE 21800 Clark Graham Baie d'urfe, Quebec H9X 4B6 CANADA David Smith Phone: 514 457 0701 dsmith@scpscience.com REFERENCE MATERIAL PRODUCER Valid To:
More informationENVIRONMENTAL GUIDANCE NOTES: ENVIRONMENTAL STANDARDS AND LIMITS
ENVIRONMENTAL GUIDANCE NOTES: ENVIRONMENTAL STANDARDS AND LIMITS Disclaimer: The information contained in this communication document is intended solely for the use of guidance cannot be considered as
More informationAPPENDIX I. LAMPIRAN I - RKL DAN RPL KEGIATAN TERPADU PROYEK PENGEMBANGAN TANGGUH LNG i
APPENDIX I Table 1 Emission Standards from Flare, Gas Turbine, Boiler, Acid Gas Incinerator and Internal Combustion Engine... 1 Table 2 n-hazardous Waste Incinerator Standard... 3 Table 3 Hazardous Waste
More informationAnnex 7.1 National Ambient Air Quality Standards for Nepal, 2003
Annex 7.1 National Ambient Air Quality Standards for Nepal, 2003 Parameters Units Averaging Time TSP (Total Suspended Particulars) Concentration in Ambient Air, maximum Test method µg/m 3 Annual - 24-hours*
More informationSchedule of Accreditation
Schedule of Accreditation Organisation Name Bord Na Mona Environmental Ltd Trading As INAB Reg No 83T Contact Name Roisin Kavanagh Address Main Street, Newbridge, Kildare Contact Phone No 045-439754 Email
More informationCALA Directory of Laboratories
CALA Directory of Laboratories Membership Number: 2635 Laboratory Name: Taiga Environmental Laboratory Parent Institution: Government of Northwest Territories (GNWT) Address: P.O. Box 1320 4601-52nd Avenue
More information2014 ASSINIBOINE RIVER MONITORING REPORT
October 15, 2014 Temperature º C 9.7 9.6 9.6 9.6 9.7 9.7 10.1 10.2 10.1 Dissolved Oxygen mg/l 10.3 10.2 10.2 10.3 10.1 10.2 10.2 10.2 10.2 Conductivity ms/cm 1.262 1.235 1.253 1.307 1.315 1.307 1.322 1.32
More informationEnvironmental Laboratory Accreditation Program Scope of Certification
Environmental Laboratory Accreditation Program Scope of Certification THIS LISTING OF FIELDS OF ACCREDITATION MUST BE ACCOMPANIED BY CERTIFICATE NUMBER: 822620 State Laboratory ID: 027-005-336 EPA Lab
More informationThis annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation
Location(s) where activities are performed under accreditation Head Office Wenkebachstraat 1 1951 JZ Velsen-Noord The Netherlands Location Abbreviation/ location code Wenkebachstraat 1 1951 JZ Velsen-Noord
More informationTE Laboratories Ltd.
TE Laboratories Ltd. Loughmartin Business Park, Tullow, Co. Carlow. Testing Laboratory Registration number: 106T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the
More informationDR 1900 PORTABLE SPECTROPHOTOMETER
DR 1900 PORTABLE SPECTROPHOTOMETER Applications Drinking Water Wastewater Field Use Industrial Water Power Carry more water methods with you wherever you need them most. The DR 1900 combines the ruggedness
More informationCALA Directory of Laboratories
CALA Directory of Laboratories Membership Number: 1429 Laboratory Name: Saint John Laboratory Services Ltd. Parent Institution: Address: 1216 Sand Cove Rd. Saint John NB E2M 5V8 Contact: Dr. Apollos Ikejiani
More informationAppendix I. Agreement on National Environmental Standards of Lao PDR, 2009
Appendix I Agreement on National Environmental Standards of Lao PDR, 2009 I.1 DRINKING WATER QUALITY STANDARDS Lao PDR current standards for drinking water of the Lao PDR are provided below for reference.
More informationIndependent Analytical Supplies Ltd (Trading as) IAS Laboratories
Independent Analytical Supplies Ltd (Trading as) IAS Laboratories Unit 4 Bagenalstown Business Park, Bagenalstown, Co Carlow Testing Laboratory Registration number: 275T is accredited by the Irish National
More informationState of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation
Matrix: CWA (Non Potable Water) Discipline: Chemistry ASTM D516-07 ASTM D6888-09 ASTM D7511-09e2 EPA 160.4 EPA 1631E EPA 1664A EPA 1664A (SGT-HEM) EPA 180.1 Sulfate 8/1/2018 Cyanide, Amenable 8/1/2018
More informationQUESTIONNAIRE FOR GENERAL WTP REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : groundwater (well pit); urban wastewater;
REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : ENVIRONMENTAL DATA - Temperature min. : C - Temperature max. : C - Altitude (m.a.s.l) : m - Plant location (geographic area, seismic zone,
More informationState of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation
Matrix: CWA (Non Potable Water) Discipline EPA 120.1 Chemistry Conductivity 8/1/2015 Aluminum 8/1/2015 Antimony 8/1/2015 Arsenic 8/1/2015 Barium 8/1/2015 Beryllium 8/1/2015 Boron 8/1/2015 Cadmium 8/1/2015
More informationSCOPE OF ACCREDITATION TO ISO 17034:2016
SCOPE OF ACCREDITATION TO ISO 17034:2016 SCP SCIENCE 21800 Clark Graham Baie d'urfe, Quebec H9X 4B6 CANADA David Smith Phone: 514 457 0701 dsmith@scpscience.com REFERENCE MATERIAL PRODUCER Valid To: November
More informationSpecifies test methods that cover the determination of chloride ion in water, wastewater and brines.
: 2018-03-22 List of Standards and Abstracts Page No : 1 Of 16 Title Abstract Corr SANS 163-1 SABS ISO 10304-1 2015 2.00 ST Specifies a method for the determination of dissolved (ISO 10304-1:2007, IDT,
More informationEnvironmental Laboratory Accreditation Program Scope of Certification
Environmental Laboratory Accreditation Program Scope of Certification THIS LISTING OF FIELDS OF ACCREDITATION MUST BE ACCOMPANIED BY CERTIFICATE NUMBER: 1385666 State Laboratory ID: 027-005-336 EPA Lab
More informationSchedule of Accreditation
Schedule of Accreditation Organisation Name Sourn Scientific Services INAB Reg No 194T Contact Name Catriona Donovan Address Unit 4, 4Park Business Centre, Farranfore, Kerry Contact Phone No 0669763588
More informationKits. Item Product name Article Number 1 ACIDITY TEST AQUAMERCK ALCOHOL TEST MG/L REFLECTOQUANT
Kits Item Product name Article Number 1 ACIDITY TEST AQUAMERCK 1.11108.0001 2 ALCOHOL TEST 15-150 MG/L REFLECTOQUANT 1.17946.0001 3 ALKALINITY TEST AQUAMERCK 1.11109.0001 4 ALUMINIUM TEST 0.020-1.20 MG/L
More informationSchedule. This laboratory has demonstrated its technical competence to operate in accordance with MS ISO/IEC 17025:2005 (ISO/IEC 17025:2005).
LABORATORY LOCATION: (PERMANENT LABORATORY) EUROFINS NM LABORATORY SDN. BHD. NO. 27, JALAN IMPIAN EMAS 5 TAMAN IMPIAN EMAS 81300 SKUDAI, JOHOR MALAYSIA Page: 1 of 6 FIELD OF TESTING: CHEMICAL This laboratory
More informationQUALITY ASSESSMENT of WATER and WASTEWATER
QUALITY ASSESSMENT of WATER and WASTEWATER Mamta Tomar LEWIS PUBLISHERS Boca Raton London New York Washington, D.C. Contents Chapter 1 Introduction 1 Chapter 2 Safety in the Laboratory 5 2.1 Basic Rules
More informationSIX MONTHLY REPORT OF EMP CLEARANCE J11015/536/2008- IA-II(M) FOR THE PERIOD OCTOBER-2014 TO MARCH-2015 (1 ST June 2015)
SIX MONTHLY REPORT OF EMP CLEARANCE J11015/536/2008- IA-II(M) FOR THE PERIOD OCTOBER-2014 TO MARCH-2015 (1 ST June 2015) ARA OCP (ARA SARUBERA GROUP OF MINES) KUJU AREA CENTRAL COALFIELDS LIMITED (A Miniratna
More informationAccredited Laboratory
Accredited Laboratory A2LA has accredited MICROBAC LABORATORIES, INC., KTL Louisville, KY for technical competence in the field of Chemical Testing This laboratory is accredited in accordance with the
More informationWarm Mineral Springs Sampling by Sarasota County
Warm Mineral Springs Sampling by Sarasota County John Ryan, Kathryn Meaux, Rene Janneman and Jon S. Perry Sarasota County Environmental Services Sarasota, Florida September 11 Warm Mineral Springs is a
More informationMicro Methods Laboratory Quality Assurance Manual
15.2 List of Approved Methods Petroleum Analysis Methodology Reference Table Method ASTM 977 ASTM C25 ASTM C39 ASTM D129 ASTM D1298 ASTM D156 ASTM D1744 ASTM D189 ASTM D2159 ASTM D2270 ASTM D2276 ASTM
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MICROBAC LABORATORIES, INC., KTL DIVISION 3323 Gilmore Industrial Blvd. Louisville, KY 40213 Megan Rothgerber Phone: 502 962 6400 CHEMICAL Valid To: December
More informationAs a reminder, continued participation in the Ecology Lab Accreditation Program requires the lab to:
April 11, 2017 Mr. Brad Barfuss 350 Hills Street Suite 107 Richland, WA 99354 Dear Mr. Barfuss: Thank you for your application for renewal in the Environmental Laboratory Accreditation Program. Enclosed
More informationCE 370. Wastewater Characteristics. Quality. Wastewater Quality. The degree of treatment depends on: Impurities come from:
CE 37 Wastewater Characteristics Quality Wastewater Quality The degree of treatment depends on: Influent characteristics Effluent characteristics Impurities come from: Domestic activities Industrial activities
More informationMethod Analytical principle Relation to standards. Ammonium Gas diffusion/ ph-indicator DIN EN ISO (Ammonia)
FIA List of Methods Release: 24.03.2016 Total Pyrocatechol violet APHA 3500 Al modified Aluminium 0.01 mg/l 0.05... 0.5 mg/l Al-T Water / Wastewater 0.2... 2 mg/l Al-T Ammonium Gas diffusion/ ph-indicator
More informationMECON LIMITED RANCHI , INDIA
ORISSA MINING CORPORATION LIMITED BANGUR CHROMITE MINING PROJECT POST CLEARANCE ENVIRONMENTAL MONITORING REPORT FOR THE MONTH OF JULY 2011 MECON LIMITED RANCHI 834 002, INDIA 11.S2.2011 SEPTEMBER, 2011
More informationPoint wise compliance for the conditions stipulated in Environmental Clearance of (Phase- I & II)
SIX MONTHLY ENVIRONMENTAL COMPLIANCE STATUS REPORT (PERIOD : OCT, 2017 to MARCH, 2018) Ref: J-13011/23/2007-IA-II (T) Dated: 17/07/2007 (as amended in the Year, 2013 & 2014) and J-13011/46/2007-IA-II (T)
More informationENVIRONMENTAL LABORATORY LICENSE. ACZ Laboratories, Inc. AZ0102
ARIZONA DEPARTMENT OF HEALTH SERVICES ENVIRONMENTAL LABORATORY LICENSE Issued to: Laboratory Director: Owner/Representative: Brett Dalke Matt Sowards ACZ AZ0102 is in compliance with Environmental Laboratory
More informationhaving examined Legislative Decree No.21 of 1996 with respect to the and Ministerial Order No.10 of 1999 with respect to the Environmental
MINISTERIAL ORDER NO.3 OF 2001 WITH RESPECT TO AMENDING CERTAIN SCHEDULES ATTACHED TO MINISTERIAL ORDER NO.10 OF 1999 WITH RESPECT TO ENVIRONMENTAL STANDARDS (AIR AND WATER) AS AMENDED BY MINISTERIAL ORDER
More information1. Introduction. 2. Scope and application. 3. Objectives
MANUAL 2 4 1. Introduction 2. Scope and application 3. Objectives 4. Location of measurements and sampling 6 Layer type Soil Soil Solution Soil properties Moisture probe Zerotension Tension lysimeter
More informationKirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent
Kirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent wastewater requirements. In Russia, there are strict
More informationSWANA 2017 Leachate Basics and Quality Changes with Organics Removal. Steve Johnson M.Eng., P.Eng.
SWANA 2017 Leachate Basics and Quality Changes with Organics Removal Steve Johnson M.Eng., P.Eng. May 2017 2 Landfills that take over 10,000 tonnes per year? How many of you have leachate collection systems?
More informationCALA Directory of Laboratories
CALA Directory of Laboratories Membership Number: 2749 Laboratory Name: Metro Vancouver - Quality Control Laboratory Parent Institution: Metro Vancouver Address: 1299 Derwent Way Delta BC V3M 5V9 Contact:
More informationSCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS
SCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS UNIT TOLERANCE LIMIT NO. PARAMETER TYPE OF LIMIT VALUES 01 Total suspended solids mg/1,
More informationWEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month
WEATHER MONITORING ELE Weather Sensors 411 E 215 pw 646 pm Wide ranging expandable air monitoring system, particularly suitable for ambient air analysis Includes sensors for: Wind speed Wind direction
More informationPRICE LIST EFFECTIVE JANUARY 1ST 2018
Metals Single Metal (excluding Mercury) EPA 200.7/6010/200.8/6020 $15.00 Precious Metals (Call to confirm the metal) EPA 200.7/6010/200.8/6020 $50.00 Metals Digestion (per sample) EPA 3010/3050 $10.00
More informationNational Association of Testing Authorities, Australia SCOPE OF ACCREDITATION
National Association of Testing Authorities, Australia SCOPE OF ACCREDITATION Environmental Analysis Laboratory Division of Research, Southern Cross University SOUTHERN CROSS UNIVERSITY Accreditation Number:
More informationEESTI AKREDITEERIMISKESKUS LISA I OÜ Tepso Labor akrediteerimistunnistusele K003 ANNEX 1 to accreditation certificate K003 of Tepso Labor Ltd
Leht Page 1(3) EESTI AKREDITEERIMISKESKUS LISA I OÜ Tepso Labor akrediteerimistunnistusele K3 ANNEX 1 to accreditation certificate K3 of Tepso Labor Ltd 1. Akrediteerimisulatus kalibreerimiste osas on
More informationDR1000 Flying Laboratory, Drone Environmental Monitoring
cccc DR1000 Flying Laboratory, Drone Environmental Monitoring 1 P a g e Mission Statement The Scentroid DR1000 is a fully capable flying laboratory, used to sample and analyze ambient air at heights of
More informationSABS Water Check. Inorganic Chemical proficiency testing provider for water laboratories. NLA 20 September 2011
SABS Water Check Inorganic Chemical proficiency testing provider for water laboratories NLA 20 September 2011 Presenter biography Chris Fouché Current Manager of SABS Food & Water Chemistry/ PTS Provider
More informationMECON LIMITED RANCHI , INDIA
ORISSA MINING CORPORATION LIMITED BANGUR CHROMITE MINING PROJECT POST CLEARANCE ENVIRONMENTAL MONITORING REPORT FOR THE MONTH OF SEPTEMBER 2011 MECON LIMITED RANCHI 834 002, INDIA 11.S2.2011 OCTOBER, 2011
More informationFate and Transport of Wheat in the Athabasca River: R&D in the context of a grain derailment response strategy. Karla Graf Loni Waldner, P.Eng.
Fate and Transport of Wheat in the Athabasca River: R&D in the context of a grain derailment response strategy Karla Graf Loni Waldner, P.Eng. Objectives Provide sustainable remediation by minimizing the
More informationCALA Directory of Laboratories
CALA Directory of Laboratories Membership Number: 3573 Laboratory Name: AGAT Laboratories (Grande Prairie) Parent Institution: AGAT Laboratories Ltd. Address: 10203B - 123 Street Grande Prairie AB T8V
More informationCALIFORNIA STATE ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing
CALIFORNIA STATE ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing Basic Laboratory, Inc. 2218 Railroad Avenue Redding, CA 96001 Phone: (530) 243-7234 Field of Testing: 101 -
More informationEnvironmental Performance Test of Hazardous Waste Incinerator in Indonesia
Environmental Performance Test of Hazardous Waste Incinerator in Indonesia Prof. Kardono, Ph.D. Environmental Technology Center Agency for the Assessment and Application of Technology (BPPT) Jakarta, INDONESIA
More informationParameter monitored Standard methodology used Detection limit
A. Water sampling and analysis ph Potentiometry 0.0 ph units No Temperature Electrometer probe (in-situ) 0.05 o C No Dissolved oxygen Electrometer probe (in-situ) % No Salinity Electrometer probe (in-situ)
More informationLIST OF TESTING SERVICES CHEMICAL
-MATERIAL A. Soil LIST OF TESTING SERVICES 1 Water Soluble Chloride Content in Soil BS 1377 Part 3 2 Acid Soluble Chloride Content in Soil BS 1377 Part 3 3 Water Soluble Sulphate Content in Soil BS 1377
More informationDublin City Council. Central Laboratory, Eblana House, Marrowbone Lane, Dublin 8. Testing Laboratory Registration number: 079T
Dublin City Council Central Laboratory, Eblana House, 68-70 Marrowbone Lane, Dublin 8 Testing Laboratory Registration number: 079T is accredited by the Irish National Board (INAB) to undertake testing
More informationDetroit Water and Sewerage Department Water Quality Division Laboratory Analysis of Water Samples Collected at Lake Huron Plant 6/9/2015
Lake Huron Plant Turbidity NTU 0.35 0.05 0.3/95% (1) Total Solids mg/l 136 162 500 10 Total Dissolved Solids mg/l 145 136 500 10 Aluminum Al mg/l 0.510 0.142 0.05-0.2 0.005 Iron Fe mg/l 0.082 0.118 0.3
More informationREPORT NUMBER REPORT DATE SEND TO ISSUE DATE Apr 18, Apr 18, 2017 RECEIVED DATE Apr 05, 2017
PAGE 1/7 Sample ID: EWA PELLETS Lab Number: 2653281 Date Sampled: 2017-04-04 0850 Carbon nitrogen ratio C/N 6 : 1 0.1 Calculation Auto-2017/04/12 Auto-2017/04/18 Carbon (total) 38.53 % 0.050 ASTM D 5373
More informationEPA USGS I EPA SM 4500-NH 3 B [18 th, 19 th, 20 th ] AOAC SM 4500 NH 3 C [19 th, 20 th ] SM 4500 NH 3 E [18 th ]
2. Alkalinity, as CaCO 3, mg/l 1. Electrometric or Colorimetric titration to ph 4.5, manual or EPA 310.1 1 SM 2320 B [18 th, 19 th, 20 th ] ASTM D1067-92 USGS I-1030-85 2 AOAC 973.43 3 FR 3/12/07 SM 2320
More informationAs a reminder, continued participation in the Ecology Lab Accreditation Program requires the lab to:
April 9, 2015 Ms. Elisa Nguyen Energy Northwest Environmental Services Lab 350 Hills Street Suite 107 Richland,WA 99354 Dear Ms. Nguyen: Thank you for your application for renewal in the Environmental
More information1. How many moles of calcium chloride are there in a sample containing x particles? l
1. How many moles of calcium chloride are there in a sample containing 1.0038x 10 22 particles? l 2. A sample of water contains 3.01x10 23 water molecules a. How many moles of water molecules are present
More informationPanasonic India Pvt. Ltd.
Panasonic India Pvt. Ltd. December-2014 FOR Industrial Building of Panasonic India Ltd At Jhajjar, Haryana 1 Details of Environmental Monitoring INTRODUCTION M/s Panasonic India Pvt Ltd granted its Environmental
More informationEmission Testing June 2014 Ingal Civil Products Minto Plant
Page: 1 of 8 57-65 Airds Rd MINTO NSW 2566 June 2014 Minto Plant Dear Amit, Tests were performed 17 June 2014 to determine emissions to air from 2 locations at the Minto plant of. LICENCE COMPARISON...
More informationDrinking Water Analyses
Environmental & Analytical Services 350 Hills Street, Suite 107, Richland, WA 99354 (509) 377-8058 FAX (509) 377-8464 ANALYSES AND PRICE LIST, JANUARY 2016 TO DECEMBER 2016 Drinking Water Analyses BACTERIOLOGICAL
More informationNew Standard Methods and ASTM Methods for the Determination of Total Nitrogen in Aqueous Samples
New Standard Methods and ASTM Methods for the Determination of Total Nitrogen in Aqueous Samples William Lipps Analytical & Measuring Instrument Division August 2016 1 / 9 The current EPA definition for
More informationCertificate of Analysis
Town of Niverville ATTN: RYAN DYCK/ANDREW REMPEL PO Box 267 Niverville MB R0A 1E0 Date Received: Report Date: Version: 27-APR-16 14:57 (MT) FINAL Client Phone: 204-392-3012 Certificate of Analysis Lab
More informationZZK/CLAB-KSPCB/04/ Environmental Officer,
ZZK/CLAB-KSPCB/04/ 5491 09-10-2017 Environmental Officer, Regional Office, Karnataka State Pollution Control Board Parisara Bhavan, LIG II, B 217 B-1, Main Road, A-16th Cross Near Hari Om Trust, Habbuwadaa
More informationEurofins Food Testing Ireland Limited (Cork)
Eurofins Food Testing Ireland Limited (Cork) Glanmire Industrial Estate, Glanmire, Co. Cork. Testing Laboratory Registration number: 368T is accredited by the Irish National Board (INAB) to undertake testing
More information