TECHNICAL INFORMATION

Size: px
Start display at page:

Download "TECHNICAL INFORMATION"

Transcription

1 TECHNICAL INFORMATION HOW TO SELECT THE TRAY FOR YOUR JOB SITE TERMS & CONDITIONS DEFINITIONS 548 Nicola Place Port Coqutilam, BC V3B 0K4 Canada Direct Tel: Main Tel: Toll Free: Tel:

2 HOW TO SELECT CABLE TRAY 1. MATERIAL AND FINISH CODE Tray is offered in a variety of material types and finishes - aluminum, steel, stainless steel, paint ready. Refer to the material and finishes pages for more detail. Consideration should be given to environmental concerns, cost and application. 2. TRAY LOAD RATING CLASS The table to the right is the CSA load/span class designation. The classes are C1, D1, and E and you will note that the maximum load rating varies depending on the class and support spacing. Note: C,D and E are the conventional CSA designations. 8A / B/C, 12A / B/C, 16A / B/C AND 20A / B/C are the traditional NEMA designations. It is important to consider the load your cable tray will endure. Consider the following when calculating the load: cable weight, snow, ice and wind. 3. STYLES OF TRAY There are three different styles of cable tray: Ladder / Ventilated / Solid LOAD / SPAN CLASS DESIGNATION (CSA C22.2 # ) Span m (ft) Load kg/m 2.4(8) 3.0(10) 3.7(12) 4.9(16) 6.0(20) (lb/ft) 37 (25) A 67 (45) D 74 (50) 8A 12A 16A 20A 97 (65) C 112 (75) 8B 12B 16B E 149 (100) 8C 12C 16C 20C 179 (120) D 299 (200) E CODE cable tray systems are manufactured to conform to the standard load classes of CSA as follows: CSA Class Designation CODE Designation Side Rail Height Rated Load (Kg / m) Rated Span (m) C1 C C D1 D D3m D E E SELECT TRAY SIZE WIDTH E AND HEIGHT There are different widths and heights of cable tray and what you require will depend on number, size, and weight of the cables in the tray. CODE standard widths are available in 15cm, 30cm, 45cm, 60cm, 75cm, and 90cm. Height is available for the siderail as follows: C1-102mm (4 ) D1, D3m & E1 = 115mm (4 1/2) C6, D6, E6 = 150mm (6 ) 5. FITTINGS Cable tray fittings are designed to change the size or direction of the cable tray. One must consider the Tel:

3 HOW TO SELECT CABLE TRAY radius of the bend, whether vertical or horizontal. Standard radius are available in 30cm, 60cm, 90cm. Custom sizes can be factory ordered. Fittings are also used for angle situations and are available in 30, 45, 60, and CONSIDER THERMAL EXPANSION & CONTRACTION A cable tray my be affected by thermal expansion and contraction, which must be taken into account during installation. To determine the number of expansion splice plates you need, decide the length of the straight cable tray runs and the total difference between the minimum winter and maximum summer temerpatures. To function properly, expansion splice plates require accurate gap settings between trays. Reference: NEMA VE National Electrical Manufactures Association Expansion Splice Plates 7. CONSIDER ELECTRICAL GROUNDING CAPACITY The National Electrical Code, Article allows cable tray to be used as an equipment conductor. It is important to note that cable tray is not designed to support personnel. CODE tray is a mechanical support system for cables and is not to be used as a walkway, lifting apparatus or ladder. The use should display warnings to prevent the use of cable tray for purposes other than its original intent Tel:

4 CABLE TRAY DIAGRAM *Call your CODE Sales Rep for all your box requirements 1 Ladder Tray 2 Ventilated Tray 3 Solid Tray 4 90 Horizontal Bend 5 45 Horizontal Bend 6 Horizontal Tee 7 Horizontal Cross 8 90 Vertical Inside Bend 9 90 Vertical Outside Bend 11 Vertical Tee Down 12 Frame Box Connector 13 Flat Cover 14 Peaked Cover 15 Instrumentation Channel 16 Instrumentation Channel Fitting 17 Barrier Strip 18 Right Reducer SPYDERLOK - Connection Plate The original quick connector included with all fittings and tray. Tel:

5 MATERIAL - DESCRIPTIONS ALUMINUM STEEL (PRE-GALVANIZED) STAINLESS STEEL Aluminum Steel (Pre-Galvanized) Stainless Steel Paint Ready Aluminum cable trays are fabricated from structural grade copper free (marine grade) aluminum extrusions. Aluminum s excellent corrosion resistance is due to its ability to form an aluminum oxide film that when scratched or cut, reforms the original protective film. Aluminum has excellent resistance to weathering in most outdoor applications. Aluminum cable trays can perform indefinitely, with little or no degradation over time, making it ideal for many wet environments. The resistance to chemicals, indoor and outdoor, can best be determined by tests conducted by the user with exposure to the specific conditions for which it is intended. Pre-galvanized steel, is produced in a rolling mill by passing steel coils through molten zinc. These coils are then slit to size and fabricated. Fabricated by roll forming, shearing, punching or forming to produce cable tray. Using structural quality steel assures that the material will meet the minimum yield and tensile strengths of applicable ASTM standards. The corrosion resistance of steel varies widely with coating and alloy. The pure zinc (galvanized) coating exhibits a high degree of galvanie protection to exposed steel such as at sheared edges. Stainless steel cable trays are fabricated AISI Type 304 or AISI Type 316/316L stainless steel. Both are non-magnetic and belong to the group called austenitic stainless steels. Like carbon steel, they exhibit increased strength when cold worked by roll-forming or bending. Galvanneal steel is produced in a rolling mill by passing through molten zinc directly above coating bath at 1000 F F. The final coating is with an alloy coating of 90% zinc and 10% iron. Galvanneal is used in applications to allow for ease of painting and improved coating adhesion. Galvanneal coating is very hard and not easily scratched during handling. The product can be stretched and drawn with proper manufacturing techniques. Galvanneal coating is about 10% less galvanically active in most environments because it contains 10% iron. Specific needs of the application and corrosion performance requirements tend to dictate which type of coating will perform best. Typical application: indoor & outdoor. Typical application: chemical, refrigeration, paper and food applications. Typical application: indoor, low thermal expansion, & cost effective. PAINT READY Typical application: Indoor, astetic-open ceiling. 227 Tel:

6 CABLE TRAY RAIL PROFILES - DESCRIPTION ALUMINUM CODE offers a variety of rail heights and weight loads to meet all in field applciations. I-beam construction used in the design of side rails ensure maximum transverse and longitudinal strength. Extruded aluminum ensure smooth edges, providing protection for cables. CODE cable tray systems are manufactured to conform to the standard load classes of CSA as follows: CSA Class Designation CODE Designation Side Rail Height mm in Rated Load (Kg / m) Rated Span (m) C1 C C D1 D / D3m / D E E / ALUMINUM LADDER TRAY E C D D3m D6 102mm 115mm 115mm 150mm C6 E E mm I-beam side rail design - maximize strength-to-weight ratio - smooth edges 2 Welding bead - positive rung lock - added material dispereses heat 3 Bottom flange inside - positive rung support 115mm 150mm Tel:

7 STRUCTURAL DESIGN DESIGN CODE cable tray and fittings are manufactured to CSA standard C22.2 Nn (latest version) from designs offering unprecedented attention to detail and ease of installation. All CODE designs are symmetrical, achieving maximum strength from minimum mass and feature reinforcing ribs on the side rail for strength. In addition, CODE side rails combined with the low profile rung design, offer the greatest usable inside height available in the industry. CODE unique SPYDERLOK connector requires only four fasteners per tray. No bolts or washers are required. The speed with which SPYDERLOK can be installed reduces labour costs over competitive coupling devices and ensures swift installation of tray and fittings, while providing continuity of side rail alignment and strength. In short, CODE s careful designs have been engineered from improvements and input from the industry and on exceeding all existing specifications. CONSTRUCTION The I-Beam configuration used in the design of side rails for CODE Aluminum Tray ensures maximum transverse and longitudinal strength. In ladder and ventilated designs, rung spacing is uniform both between rungs and between sections. Steel Tray side rails and rungs are continuously roll formed for added strength and to ensure smooth edges to protect cables. Our steel rungs are slotted to accommodate pipe and cable clamps. All CODE cable tray and fittings ensure optimal strength and bonding characteristics by means of welding. Metal Inert Gas (M.I.G.) welding is a semiautomatic process using inert-gas shroud over a consumable wire electrode which transfers current to melt the base material. A filler metal is also added for reinforcement. CODE cable trays offer superior welding strength because our rungs are welded on both the front as well as the back of the rungs. This is unique to CODE tray and adds additional strength to every piece of CODE tray. Our side rails and rungs are designed to allow users to attach a UC clamp without drilling or tapping the side rail. SMOOTH EDGES All aspects of both tray and rungs feature rounded edges and flat smooth surfaces to prevent damage when in contact with cables. FUTURE EXPANSION REQUIREMENTS Easily add cables to an existing system with barrier tray. Future expansion should always be considered when selecting a cable tray, and allowance should be made for additional fill area and load capacity. A minimum of 50% expansion allowance is recommended. SPACE LIMITATIONS Any obstacles which could interfere with a cable tray installation should be considered when selecting a cable tray width and height. Adequate clearances should be allowed for installation of supports and for cable accessibility. Note: The overall cable tray dimensions typically exceed the nominal tray width and loading depth. Standard length is 3m (10ft) & 6m (20ft) Depth 100mm (4 ), 150mm (6 ) and custom SPECIAL ORDERS CODE cable tray systems have been designed to easily accept special orders to suit the specification of your job. From connectors to join CODE tray to competitive products, to custom tray widths, to covers for any cable tray system on the market. Our manufacturing facility has full CAD design and CNC punching and forming capabilities. CODE s customer service staff will handle your request for quotation and delivery lead times quickly and efficiently there is nothing too custom! Tel:

8 DEFINITIONS Accessories Barrier Strip Cable Tray Support Span Cable Tray System Channel Cable Tray Connector Fitting Galvanic Corrosion Horizontal Cross Horizontal Elbow Horizontal Tee Instrumentation Channel Ladder Cable Tray Reducer Reducer Left-hand A component that is used to supplement the function of a straight section or fitting. Examples include, but are not limited to, dropout, cover, conduit adapter, hold-down devices, and barrier strip. To separate cables carrying dissimilar voltages. The distance between the centerlines of supports. A unit or assembly of units or sections, and associated fittings, forming a mechanical system used to support cable and raceways. A fabricated structure consisting of a one-piece ventilated bottom or solid bottom channel section. A component that joins a combination of cable tray straight sections and fittings. The basic types of connectors include rigid, expansion, adjustable, adnd reducer. A component that is used to change the size, direction, elevation or width of a cable tray system. Fittings are not subject to Nema/C.S.A. load ratings. Galvanic corrosion results from the electrochemical reaction that occurs in the presence of an electrolyte when two dissimilar metals are in contact. A fitting that joins cable trays in four directions at 90 degree intervals in the same plane. A fitting that changes the direction of cable tray on the same plane. A fitting that joins cable trays in three directions at 90 degree intervals in the same plane. One-piece channel section; solid or ventilated. Typically used to carry instrumentation, control, data, telephone, or cables. A fabricated structure consisting of two longitudinal side rails connected by individual transverse members (rungs). A fitting that joins cable trays of different widths in the same plane. A reducer; when viewed from the large end, a straight side on the left. Tel:

9 DEFINITIONS Reducer Right-hand Reducer Straight A reducer; when viewed from the large end, has a straight side on the right. A reducer; two symmetrical offset sides. Solid-Bottom Straight Section Support A fabricated structure consisting of a one-piece solid bottom channel section that may include louvers on the bottom face. A length of cable tray that has no change in direction or size. A component that provided a means for supporting a cable tray, including, but not limited to, cantilever bracket, trapeze, and individual rod suspension. Thermal Expansion & Contraction Accurate gap setting at time of installation when using expansion connectors. Trough or Ventilated Cable Vertical Elbow Vertical Inside Elbow Vertical Outside Elbow Vertical Tee A fabricated structure consisting of integral or separate longitudinal rails and a bottom having openings sufficient for the passage of air and utilizing 75% or less of the plane area of the surface to support cables. The maximum spacing between cable support surfaces of transverse elements do not exceed 102mm (4 ) in the direction parallel to the tray side rails. (On horizontal bends only, the maximum distance between transverse elements is measured at the centerlineof the bend.) A fitting that changes the direction of cable tray upward or downard from the horizontal plane. A fitting that changes the direction of cable tray upward from the horizontal plane. A fitting that changes direction of cable tray downward from the horizontal plane. A fitting that joins cable trays in three directions at 90 degree intervals in different planes Tel:

10 TERMS AND CONDITIONS TERMS: Net 30 days, unless otherwise stated. Interest on overdue accounts is calculated at 2% per month. In the event the customer requests a delay in shipment, payment becomes due 30 days following the originally scheduled shipping date. Federal and Provincial Sales Taxes are extra where applicable. PRICING: Goods will be billed at the price effective at the time of the order. All prices are subject to change without notice. TAXES: Any applicable taxes are extra. MINIMUM BILLING: Minimum billing is $ net of freight and taxes. SPECIAL ORDERS: For items not normally stocked by CODE Manufacturing Ltd. we reserve the right to ship and charge 10% above or below the quantity specified on the order. Special orders cannot be cancelled. If cancellation occurs, CODE will insist on payment for work performed, costs incurred and loss of profits. SHIPPING: 1. Cable Tray is always shipped F.O.B. our plant, Port Coquitlam, B.C. regardless of freight payment terms. 2. F.O.B. Freight On Board denotes that title to the shipment passes to the purchaser at the instant that the carrier signs the bill of lading. It is the responsibility of the purchaser to ensure that the shipment is received in good order, and to file a Damaged in Transport Claim with the carrier should there be damages. CODE is not responsible for any liability arising thereof, and cannot be involved in any recover process. 3. CODE will not accept any return shipment due to transport damage. 4. Should repair or replacement of goods be necessary a new purchase order must be issued to CODE Manufacturing Ltd. The purchaser is responsible for payment of both purchase orders SHIPPING DATES: Wherever and whenever possible CODE Manufacturing Ltd. (the Company) will endeavor to ship the goods on the specified date(s). At no time shall the purchaser hold CODE responsible for any delay or damage incurred due to acts of God, priorities, orders or restriction imposed by the Government, delays in transport, delays from our suppliers or delays due to labour and all delays beyond the control of CODE Manufacturing Ltd. PACKAGING: Crating is charged extra when required. Special packaging may also be charged extra. CLAIMS: Claims for errors or shortages must be made within five (5) days of receipt of goods. CANCELLATIONS: After an order has been accepted it may be cancelled only with CODE Manufacturing s written approval. RETURN MATERIAL POLICY: Only unused products in new condition and not more than one-year-old will be considered for return. Permission to return material must be obtained IN WRITING from the Company prior to return. Upon approval and issue of an RMA (return merchandise authorization) products may be returned for exchange for other goods of equal value. Request for return must give the date and invoice number covering the original shipment. A service charge will apply to all goods accepted for return. All returns are to be shipped prepaid to our plant at the risk of the consignor. The RMA must accompany the material(s). Custom and or items not stocked by CODE are non-returnable. Tel:

11 TERMS AND CONDITIONS DISCLAIMER: Ensure ladder tray system performs as designed, it is important that it is properly installed. Everything must be done in accordance with the Canadian Electric Code (CEC), Occupational Health & Safety procedures, as well as local and customer building codes. WARRANTY: In the event a product is deemed defective to CODE, such products shall be repaired or replaced. Repair or replacement is at the discretion of CODE. Under no circumstances will a credit be issued for unauthorized rework of any materials. ERRORS, OMMISSION, & CORRECTIONS: The CODE catalogue s price list, website, flyers, and any other printed or electronic literature are subject to errors and omissions. Data included in the material is subject to change without notice. All literature is updated as needed and posted online at This information is updated at CODE s discretion. Issue Date: August 2016 Revision Number: Tel:

9ZN1204NB Clamp Guide. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit Product Category

9ZN1204NB Clamp Guide. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit Product Category 9ZN1204NB Clamp Guide Cooper B-Line/Cable Tray Catalog Number 9ZN1204NB Manufacturer Cooper B-Line/Cable Tray Description ZNC CBL Tray CLMP Weight per unit N/A Product Category 20120123130154 Descriptions

More information

Com-Tray. Under Floor

Com-Tray. Under Floor Com-Tray Chalfant, a leading supplier of cable trays and systems for utilities, industrial plants, and commercial service, offers Com-Tray, a unique modular, cost-saving system for routing and protecting

More information

PATHWAYS FOR COMMUNICATIONS SYSTEMS

PATHWAYS FOR COMMUNICATIONS SYSTEMS 270528 PATHWAYS FOR PART 1 GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, and equipment for the complete installation of work called for in the Contract Documents. 1.2 SCOPE OF WORK A. This

More information

CABLE TRAY SOLUTIONS OIL & GAS

CABLE TRAY SOLUTIONS OIL & GAS CABLE TRAY SOLUTIONS OIL & GAS Maximize Returns with Innovative System Solutions Oil & Gas Industry The oil and gas industry demands performance from components used in electrical infrastructure. Thomas

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING

SECTION HANGERS AND SUPPORTS FOR PLUMBING SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

City and County of San Francisco CONTRACT No A SFO - Data Center, Building 60 SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

City and County of San Francisco CONTRACT No A SFO - Data Center, Building 60 SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SCOPE OF WORK A. Cable Trays for Communications Cabling 1. Cable Trays 2. Cable Runways 3. Basket Tray B. Cable Tray Support

More information

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017 SECTION 055213 - PIPE AND TUBE RAILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Trench Duct Class Catalog 5230CT9601R10/08

Trench Duct Class Catalog 5230CT9601R10/08 5230CT9601R10/08 2009 Class 5230 CONTENTS Application.................................................5 Unassembled Trench Duct Components.........................6 Factory Assembled Trench Duct..............................11

More information

Stainless Steel Aeration Equipment Specification

Stainless Steel Aeration Equipment Specification Section 15 Stainless Steel Aeration Equipment Specification Part 1 - General 1.01 Description A. Scope of Work 1. Furnish, install and test aeration system including air mains, drop pipes, valves, expansion

More information

Flotation Docking Systems, Inc.

Flotation Docking Systems, Inc. GENERAL SPECIFICATIONS The following data outlines the design calculations and specifications around which Flotation Docking Systems, Inc. products are constructed. The use of such information for contract

More information

Model # BARK-358-RDP

Model # BARK-358-RDP Model # BARK-358-RDP 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic/Canine coated elements. guarantees all

More information

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION CHAIN-LINK FENCES AND GATES 02821/1 SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/1 PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Chain-Link Fences: 2. Gates: horizontal slide or swing. 3. Fences installed where

More information

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

Model # 800SM-PS3. 8/3/2016 Page 1 of 8 Model # 800SM-PS3 8/3/2016 Page 1 of 8 /3/2016 Page 2 of 8 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

Model # 158-P4. 12/12/2013 Page 1 of 11

Model # 158-P4. 12/12/2013 Page 1 of 11 Model # 158-P4 12/12/2013 Page 1 of 11 2/12/2013 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

Model # 238HS-P8. 4/27/2011 Page 1 of 11

Model # 238HS-P8. 4/27/2011 Page 1 of 11 Model # 238HS-P8 4/27/2011 Page 1 of 11 4/27/2011 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM Page 1 of 6 SECTION 08 32 20 LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS SLIDING DOORS. SECTION INCLUDES OVERHEAD SLIDING TUBE ASSEMBLY, MOUNTING

More information

SECTION DECORATIVE METAL AND GLASS RAILING

SECTION DECORATIVE METAL AND GLASS RAILING SECTION 05 73 00 DECORATIVE METAL AND GLASS RAILING PART 1 GENERAL 1.1 SUMMARY A) This section includes both standard and custom handrails as shown in the contract drawings. B) These include aluminum,

More information

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification

More information

Model # 358H-PR. 4/8/2011 Page 1 of 12

Model # 358H-PR. 4/8/2011 Page 1 of 12 Model # 358H-PR 4/8/2011 Page 1 of 12 4/8/2011 Page 2 of 12 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying perforated

More information

Westgate Entrematic, Parking Security Gates Section OVERHEAD SECURITY GATE Prepared by: Digicon Information Inc. Page 1

Westgate Entrematic, Parking Security Gates Section OVERHEAD SECURITY GATE Prepared by: Digicon Information Inc. Page 1 Prepared by: Digicon Information Inc. Page 1 This section includes overhead type Parking Security Gates, as manufactured by Westgate Entrematic, a division of Helton Group of Companies. DISCLAIMER: This

More information

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

B. Polyethylene samples shall be submitted for Owner approval of color and quality. Glass Rail ENGINEERED DASHERBOARD SPECIFICATIONS PART 1 - GENERAL 1.01 PROJECT SCOPE A. Contractor shall furnish and install one complete set of steel framed dasherboards as indicated on the drawings and

More information

All panels can be supplied in a range of styles, to suit the applications pictured below.

All panels can be supplied in a range of styles, to suit the applications pictured below. Evolution Radiant panel system LPHW up to 90 C Suspended ceiling grid or soffit mounting Vertical wall surface mounting Standard widths 150mm to 900mm 1 Description Introduction Evolution by Dunham-Bush

More information

SECTION HVAC GRAVITY VENTILATORS

SECTION HVAC GRAVITY VENTILATORS SECTION 23 37 23 HVAC GRAVITY VENTILATORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

TRANSPORT II " 10.5" MOUNTING POSTS FENCE LINE POST. Classic gate shown GATE OPENING CANTILEVER GATE SAFETY WARNING

TRANSPORT II  10.5 MOUNTING POSTS FENCE LINE POST. Classic gate shown GATE OPENING CANTILEVER GATE SAFETY WARNING TRANSPORT ESTATE TRANSPORT IS TRANSPORT LINK ADAPTRACK 2"sq x.25" UPRIGHTS & DIAGONAL BRACES 1"sq x.125" PICKETS GATE TRACKS PRE-DRILLED FOR LEFT OR RIGHT OPENINGS FENCE LINE POST 13.8125" 10.5" MOUNTING

More information

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS Model # 349S-P6 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic coated elements. Ultra Play guarantees all

More information

Model # 922-S4. 12/18/2013 Page 1 of 8

Model # 922-S4. 12/18/2013 Page 1 of 8 Model # 922-S4 12/18/2013 Page 1 of 8 2/18/2013 Page 2 of 8 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

SPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide

More information

Details of technical leaflets/write-up on various pieces of equipment.

Details of technical leaflets/write-up on various pieces of equipment. Details of technical leaflets/write-up on various pieces of equipment. (1) Insulator Designs: The insulators are provided in one, two, three, or four insulator designs per location and spaced to provide

More information

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and

More information

E-Series Steel Gantry Crane

E-Series Steel Gantry Crane SPANCO PRODUCT SPECIFICATIONS 1 E-Series Steel Gantry Crane This guide can be used to prepare a bid specification for the incorporation of an E-Series Gantry Crane into a competitive bid project or application.

More information

Price Egg Crate Grille

Price Egg Crate Grille Price Egg Crate Grille Division 23 Heating, Ventilating, and Air Conditioning Section 23 37 13 Diffusers, Registers, and Grilles The following specification is for a defined application. Price would be

More information

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System SECTION 13096 RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13096-1 RF WELDED SYSTEM PART 1 GENERAL 1.1 SECTION

More information

Model # 338S-OP. 9/30/2011 Page 1 of 13

Model # 338S-OP. 9/30/2011 Page 1 of 13 Model # 338S-OP 9/30/2011 Page 1 of 13 9/30/2011 Page 2 of 13 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

Aluminum Component Pipe Railings

Aluminum Component Pipe Railings 1 SECTION 05 7360 ALUMINUM COMPONENT PIPE RAILINGS PART 1 GENERAL 1.01 SECTION INCLUDES A. Aluminum component pipe handrails and railings. 1.02 RELATED REQUIREMENTS A. Section 02 9000: Landscaping: Installation

More information

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS PART 1 GENERAL 1.01 SUMMARY Section 15140 PIPE HANGERS, This Section includes the furnishing and subsequent installation of: A. Pipe and equipment hangers, supports, and associated anchors B. Equipment

More information

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders Welcome to the O Keeffe s Guide Specification System prepared as an aid to specify in preparing written construction documents. For specification assistance with specific product applications, please contact

More information

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work. SECTION 10 5113 - METAL LOCKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

WALL MOUNTED ARTICULATING JIB CRANE

WALL MOUNTED ARTICULATING JIB CRANE SECTION 14656 WALL MOUNTED ARTICULATING JIB CRANE ***** Gorbel, Inc. manufacturers a broad range of material handling cranes including monorail, bridge, gantry, and jib cranes. Numerous work station and

More information

Industry Standard Terms & Definitions Of The Steel Deck Institute

Industry Standard Terms & Definitions Of The Steel Deck Institute Industry Standard Terms & Definitions Of The Steel Deck Institute A specialized set of jargon to describe common terms used by manufacturers and other professionals associated with the usage of Steel Deck

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

BEARING METAL STUD FRAMING

BEARING METAL STUD FRAMING L-1 Section 05410 Long Form Specification LOAD BEARING METAL STUD FRAMING This section includes axially loaded steel studs, with unique slotted top channels, usually of 0.91, 1.2 and 1.5 mm (16, 18, or

More information

DBI-SALA Uni 8 Overhead Horizontal Lifeline Cable System SECTION HORIZONTAL FALL PROTECTION - OVERHEAD CABLE

DBI-SALA Uni 8 Overhead Horizontal Lifeline Cable System SECTION HORIZONTAL FALL PROTECTION - OVERHEAD CABLE SECTION 112429.18 - HORIZONTAL FALL PROTECTION - OVERHEAD CABLE PART 1 - GENERAL 1.1 SECTION INCLUDES A. Provide overhead horizontal cable fall protection system, including end anchors, energy absorbers,

More information

A-Series Aluminum Gantry Crane

A-Series Aluminum Gantry Crane SPANCO PRODUCT SPECIFICATIONS 1 A-Series Aluminum Gantry Crane This guide can be used to prepare a bid specification for the incorporation of an A-Series Gantry Crane into a competitive bid project or

More information

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS SECTION 08 32 20 CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

SPECIFICATIONS: Architectural Aluminum Railings

SPECIFICATIONS: Architectural Aluminum Railings PART ONE: GENERAL 1.1 SUMMARY SPECIFICATIONS: Architectural Aluminum Railings A. Work in this section includes custom and standard Interior and Exterior aluminum railings and guardrails. 1.2 PERFORMANCE

More information

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck) SECTION 13125 ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

SECTION ALUMINUM GATES

SECTION ALUMINUM GATES P.O. Box 1058 370 South Athol Rd. Athol, Massachusetts 01331 Phone: (978) 249-7924 Fax: (978) 249-3072 SECTION ALUMINUM GATES PART 1 GENERAL 1.01 SCOPE OF WORK A. The CONTRACTOR shall furnish all labor,

More information

Model # 358-R48. 7/7/2011 Page 1 of 11

Model # 358-R48. 7/7/2011 Page 1 of 11 Model # 358-R48 7/7/2011 Page 1 of 11 7/7/2011 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION

More information

SECTION TURBINE VENTILATORS

SECTION TURBINE VENTILATORS SECTION 07 72 00 TURBINE VENTILATORS **This is a CSI Three-Part Specification using CSI MasterFormat 2004-2010 Section Numbers and Titles. This specification must be edited to suit your particular project.

More information

SECTION 1043 FENCE MATERIAL

SECTION 1043 FENCE MATERIAL SECTION 1043 FENCE MATERIAL 1043.1 Scope. This specification covers the material required in the construction of chainlink fence and woven wire fence. 1043.2 Basis of Acceptance. The basis of acceptance

More information

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1 GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials and services to furnish and install SECURITY

More information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions Specifiers: Click on the icon in the WD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying metal wall panels

More information

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700 SECTION 09 5113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT SECTION 220529 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Daytona Beach Pier Building Renovation Jun 2010

Daytona Beach Pier Building Renovation Jun 2010 SECTION 15060 - HANGERS AND SUPPORTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Engineers guide to structural steel savings with B-Line series cable ladder system

Engineers guide to structural steel savings with B-Line series cable ladder system Structural steel savings SSS-17 B-LINE SERIES Engineers guide to structural steel savings with B-Line series cable ladder system Table of Contents Cable Ladder Best Practice...3-4 Evolution of Project

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT Page 220529-1 SECTION 220529 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Standard Specification for Steel Welded Wire Fabric, Plain, for Concrete Reinforcement 1

Standard Specification for Steel Welded Wire Fabric, Plain, for Concrete Reinforcement 1 Designation: A 185 97 Standard Specification for Steel Welded Wire Fabric, Plain, for Concrete Reinforcement 1 This standard is issued under the fixed designation A 185; the number immediately following

More information

FORMDECK. constructions. constructions

FORMDECK. constructions. constructions FORMDECK constructions constructions Introduction Formdeck300 (FD300) is a very efficient and durable permanent metal tray formwork, reinforcement and ceiling system used for suspended concrete slab construction.

More information

STATE UNIVERSITY CONSTRUCTION FUND. UNIVERSITY CON DIRECTIVE 5-1 Issue date: October 2014

STATE UNIVERSITY CONSTRUCTION FUND. UNIVERSITY CON DIRECTIVE 5-1 Issue date: October 2014 STATE STRUCTION FUND DIRECTIVE 5-1 Issue date: October 2014 STRUCTURAL STEEL 1. General: It is the Fund's policy that the design of the structural steel is the prime responsibility of the project's Structural

More information

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS Model # BARK-420 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic/Canine coated elements. guarantees all items

More information

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems. PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe and equipment support systems. B. Inserts. 1.02 RELATED SECTIONS A. Section 15890 - Ductwork Supports. 1.03 DEFINITIONS A. Supports: Attachments, hangers,

More information

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 13686.00 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 230529-1 SECTION 230529 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 1.1 SUMMARY A. Section Includes: 1. Metal pipe hangers and supports.

More information

Specifications for FL-100 Soffit Panel

Specifications for FL-100 Soffit Panel Union Corrugating Company Specifications for FL-100 Soffit Panel SECTION 07410 METAL SOFFIT PANELS PART 1 GENERAL 1.1 DESCRIPTON A. Section Includes: 1. Preformed metal soffit panel system 2. Associated

More information

1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures.

1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures. BID OPPORTUNITY NO. 253-2011 PAGE 1 OF 7 PART 1 GENERAL 1.1 REFERENCES.1 American Society of Mechanical Engineers (ASME).1 ASME B31.1, Power Piping, B31.3 Process Piping, B31.9 Building Services Piping..2

More information

Installation Guidelines for ITW Insulation Systems Metal Jacketing Used on Insulated Pipe

Installation Guidelines for ITW Insulation Systems Metal Jacketing Used on Insulated Pipe Installation Guidelines for ITW Insulation Systems Metal Jacketing Used on Insulated Pipe 1 SCOPE 1.1 This guideline covers the installation of ITW Insulation Systems Pabco-Childers brand aluminum and

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT SECTION 220529 - HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The General Conditions, Special Conditions and Division 1 through Division 22 as set forth in

More information

A. Access doors and frames are part of an access door and frame allowance.

A. Access doors and frames are part of an access door and frame allowance. SECTION 08 31 13 ACCESS DOORS AND FRAMES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Soffitto System A track-based, vertically-suspended system for display

Soffitto System A track-based, vertically-suspended system for display Soffitto System A track-based, vertically-suspended system for display B&N Industries, Inc. Main office: 1409 Chapin Avenue, 2nd Floor Burlingame, California 94010 (800) 350-4127 www.bnind.com New York

More information

A. Product Data shall be provided for each type of product indicated.

A. Product Data shall be provided for each type of product indicated. 32 31 13 CHAIN LINK FENCES AND GATES SECTION 1 GENERAL 1.1 SUMMARY This Section includes the following: 1. Chain Link Fences 2. Gates for Chain Link Fences. See electrical specifications for electrical

More information

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets Seismic Frame Two-Post Rack Page 11-3 Seismic Protection Products - Racks Page 11-6 Seismic Protection Products - Runway Page 11-8 Seismic

More information

Section 906. STRUCTURAL STEEL

Section 906. STRUCTURAL STEEL 906.01 Section 906. STRUCTURAL STEEL 906.01. General Requirements. Finished rolled shapes must be free from imperfections that affect strength and durability in accordance with ASTM A 6. Rolled shapes

More information

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE This specification is intended to describe the general requirements applicable to a proper structural cantilever rack design. In addition, it is

More information

Division 11 - Equipment Section 11401

Division 11 - Equipment Section 11401 PART 1 - GENERAL 1.1 GENERAL A. Division 1 General Requirements applies and becomes a part of this Section of the Specification as fully as if repeated herein. B. Items of equipment which are included

More information

8.1.2 Under no circumstances shall a service entrance be left unmetered. Notify the Company if an unmetered service is encountered.

8.1.2 Under no circumstances shall a service entrance be left unmetered. Notify the Company if an unmetered service is encountered. 2012 Edition Redbook 8.0 REVENUE METERING 8.1 INTRODUCTION The purpose of this section is to outline requirements of the Customer, as set forth herein by LIPA, as they pertain to Electric Revenue Metering

More information

SECTION PIPE AND TUBE RAILINGS PART 1- GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY 1.3 PERFORMANCE REQUIREMENTS

SECTION PIPE AND TUBE RAILINGS PART 1- GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY 1.3 PERFORMANCE REQUIREMENTS SECTION 055213- PIPE AND TUBE RAILINGS PART 1- GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

GUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION REROOFING ADJUSTABLE FRAMING SYSTEM

GUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION REROOFING ADJUSTABLE FRAMING SYSTEM - --- -- ----..-------~------------------------------------ GUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION 07415 REROOFING ADJUSTABLE FRAMING SYSTEM PART 1 - GENERAL 1.01 SCOPE A.

More information

Specifications Electrical Metallic Tubing (EMT)

Specifications Electrical Metallic Tubing (EMT) T& Fittings Specifications Electrical Metallic Tubing (EMT) Ref. CEC Rule 12-000 not exceeding 750 Volts Electrical Metallic Tubing (EMT) is similar to rigid steel conduit but is much lighter, weighing

More information

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS Page 1 of 6 SECTION 08 32 20 HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED BI-FOLD GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

Power Electronics, Inc. Packaged Equipment Center Standard Construction and Design Features

Power Electronics, Inc. Packaged Equipment Center Standard Construction and Design Features DESIGN CRITERIA FOR STANDARD CONSTRUCTION: These standard design elements of the P.E.I. Power Equipment Center are utilized to meet the following design criteria per ASCE 7-05 as adopted by the IBC (International

More information

1470 Dale Court Austell, GA Phone: Fax:

1470 Dale Court Austell, GA Phone: Fax: 1470 Dale Court Austell, GA 30168 Phone: 404-351-2202 Fax: 404-351-2203 LC METALS, INC. PRODUCT INDEX Page # STUD GUARDS...3 FHA STRAPS...3 BOCA PLATES (Nail Plates)...4 PLUMBERS TAPE (Banding Iron)...4

More information

Residential Commercial Industrial

Residential Commercial Industrial Enhance your property with the elegance, beauty and durability of high strength aluminum fencing. Residential Commercial Industrial www.gemstonealuminum.com Why... We ship you what you order! We ve looked

More information

RIGID LIFELINES PRODUCT SPECIFICATIONS 1

RIGID LIFELINES PRODUCT SPECIFICATIONS 1 RIGID LIFELINES PRODUCT SPECIFICATIONS 1 This guide can be used to prepare a bid specification for the incorporation of a Ceiling-Mounted Monorail Anchor Track System into a competitive bid project or

More information

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following: SECTION 10501 PERSONNEL DUTY LOCKERS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 specifications

More information

SECTION BASIC ELECTRICAL REQUIREMENTS

SECTION BASIC ELECTRICAL REQUIREMENTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions, apply to work of this section. 1.2 SUMMARY A. This section specifies

More information

SECTION EXTERIOR GRILLS AND SCREENS

SECTION EXTERIOR GRILLS AND SCREENS SECTION 10 82 13 PART 1 GENERAL PART 1 1 SUMMARY A. Section Includes: 1. Exterior perforated aluminum screen wall system with Ombrae TM Optical Tile imaging technology. 2. Accessories including attachments,

More information

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein. SECTION 10530 - EXTRUDED ALUMINUM WALKWAY COVERS PART I - GENERAL.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General, Supplementary, and Special Conditions and Division

More information

DARTMOUTH COLLEGE DESIGN September 15, 2004 &CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN September 15, 2004 &CONSTRUCTION GUIDELINES PART 1 DESIGN DIRECTIVE 1.1 RELATED DOCUMENTS SECTION 15240 SEISMIC RESTRAINT AND VIBRATION CONTROL A. This section shall be considered as a part of each DC Standards, Part 15. 1.2 QUALITY ASSURANCE A.

More information

SECTION LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS

SECTION LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS Page 1 of 9 SECTION 10 2238.13 LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED FOLDING GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500 07721 ROOF ASSEMBLY SUPPORTS FOR ROOFTOP EQUIPMENT ****************************************** SPECIFIER: All roof-related items above or outside the structural roof deck, including such work as blocking,

More information

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING 7160 Krick Rd., Walton Hills, OH 44146 800-321-3827 - Tel 440-439-8650 - Fax 440-439-6889 SECTION 12 48 16 ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING PART 1. GENERAL 1.01 SUMMARY: This section includes

More information

PRICES: DESIGN: TAXES:

PRICES: DESIGN: TAXES: CLICK HERE TO START TERMS AND CONDITIONS AGREEMENTS: All agreements are subject to strikes, accidents or other causes beyond our control. GUARANTEE: We guarantee for one year from date of delivery our

More information

CURTAINWALL DEFLECTION SOLUTIONS

CURTAINWALL DEFLECTION SOLUTIONS l l l l l CURTAINWALL DEFLECTION SOLUTIONS Provides lateral support for curtain wall systems. One of the highest tested load capacities available. Direct attachment to web and support. Most clips are reversible.

More information

D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4" x 4" x 3/8" Brace. C8 x 4.25 Strut. WT9 x 17.5.

D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4 x 4 x 3/8 Brace. C8 x 4.25 Strut. WT9 x 17.5. Sign length minus Adjust to avoid interference with sign legend A Deck fascia A 6" Equal Equal 6" Sign length (L) varies 6 to 12 PLAN 0 CONNECTION (DECK FASCIA) Angle connection assembly F Face of concrete

More information