Natural gas transport contract. Appendix B1: Rules for subscription and allocation on the Main Grid

Size: px
Start display at page:

Download "Natural gas transport contract. Appendix B1: Rules for subscription and allocation on the Main Grid"

Transcription

1 Natural gas transport contract Appendix B1: Rules for subscription and allocation on the Main Grid Version of 1st January 2016

2 Contents 1. DESCRIPTION OF THE CAPACITY OFFER ON THE MAIN GRID GENERAL RULES REGARDING SUBSCRIPTION REQUESTS SUBSCRIPTION OF CAPACITIES ON THE MAIN GRID Transport Transport Interconnection Points (PIR and PE) GRTgaz South/TIGF interconnection Pirineos VIP Procedure for returning capacities of one or more months At the storage interconnection points (PITS) At the exit points (PS) SECONDARY CAPACITIES MARKET Transfer arrangements Complete transfer Sale of the usage right Common arrangements Time frame for carrying out a capacity exchange on the TIGF grid LONG-TERM USE-IT-OR-LOSE-IT (LT-UIOLI) PRINCIPLE USE IT AND BUY IT (UBI) PRINCIPLE Natural gas transport contract Appendix B.1: Rules for subscription and allocation on the Main Grid 2

3 1. DESCRIPTION OF THE CAPACITY OFFER ON THE MAIN GRID The daily capacities marketed on the main grid relate to the entries into the transmission network (PE), the exits to the regional grid (PS), the exits to the adjacent grids (PIR) and the interconnections with storage (PITS). They can be subscribed for a day, a month (or several months at the PIR and PE), one or more seasons, or one or more years. From 1 st March 2014, capacities sold by TIGF at the Pirineos virtual interconnection point are subject to the CAM (Capacity Allocation Mechanisms) network rules: the maturities of products sold are henceforth annual, quarterly, monthly and daily. Existing (thus already subscribed) capacities remain valid until they expire, in accordance with the CRE deliberation of 29 January 2014 deciding on changes in prices for the use of natural gas transmission systems from 1 st April 2014 (paragraph VI.B.4). TIGF sells capacities in the following order of priority: - Firm technical capacities made available by TIGF, - Capacities offered by shippers under article 3.1.4, - Capacities retroceded by shippers under article 5, - Additional capacities, - Interruptible capacities. 2. GENERAL RULES REGARDING SUBSCRIPTION REQUESTS Rule 1 All subscription requests must be made through the TETRA subscription site at the disposal of Shippers, apart from capacities auctioned on the PRISMA platform, capacities returned to the PITTs, daily capacities at the PITSs and PITDs, and hourly capacities at the PICs that are different from the reference hourly capacities. Rule 2 Requests made via TETRA are binding on the Shippers. To be taken into account by TIGF, the subscription request must include: a) The grid in question (Main or Regional) b) The daily capacity value, c) The transport grid point in question (point type, point code and point description) d) The period of validity (start and end dates) e) The nature of the capacity (Firm or Interruptible), f) The frequency (annual, multi-annual, quarterly, multi-quarter, monthly, multi-month, daily). Rule 3 For subscription requests with an annual, multi-year, quarterly or multi-quarter, monthly or multi-month frequency on the main or regional grid, TIGF undertakes to respond within 5 business days. Rule 4 For a subscription request with a daily frequency, TIGF undertakes to respond: - Within five (5) business days if a subscription request is submitted between the 21st Day of Month M-1 and D-6, Natural gas transport contract Appendix B.1: Rules for subscription and allocation on the Main Grid 3

4 Rule 5 - At the latest by 6:30 PM on D-1 if a subscription request is submitted between D-6 and 2.30 PM on D-1. TIGF accepts capacity reservations without a Transport contract, provided that such a contract is in effect on the earliest of the following dates: Rule 6-15 business days before the beginning of the validity period for the capacities business days after the reservation, whether it is made within the general framework of the First Come, First Served rule or after an allocation at the end of an Open Subscription Period (OSP). If the Transport contract does not take effect within the time frames specified in the previous rule, the reservation is cancelled and the corresponding capacities are again made available to Shippers. 3. SUBSCRIPTION OF CAPACITIES ON THE MAIN GRID 3.1 Transport Transport Interconnection Points (PIR and PE) On its web site ( TIGF publishes: the marketable, subscribed and available firm and interruptible capacities at the PE and PIR, over a period of 18 sliding months marketable capacities returned, capacities returned and reallocated, available returned capacities, for illustrative purposes, the firm marketable capacities at the PE and PIR over 10 years This publication is updated as the need arises GRTgaz South/TIGF interconnection The GRTgaz South/TIGF PITT disappeared on 1 st April 2015 with the creation of the Trading Region South. Existing capacities already allocated in previous OSPs and valid at this point thus lapse as of this date Pirineos VIP On 1 st October 2014, the PITT Larrau and Biriatou PITTs were merged in commercial terms to form a single virtual interconnection point called "Pirineos". All capacities at the Larrau PITT and the Biriatou PITT were automatically transferred to the Pirineos PITT on 1 st October 2014, in accordance with CRE deliberation of 13 February 2014 deciding on the staggered implementation of the European gas networks code regarding allocation of gas transmission capacities at interconnection points between entry-exit zones. Natural gas transport contract Appendix B.1: Rules for subscription and allocation on the Main Grid 4

5 ENAGAS and TIGF sell capacities in a coordinated manner to the Pirineos PITT in accordance with the rules set out in Appendix E.1 " Procedure for marketing capacities at the Pirineos virtual interconnection point" Procedure for returning capacities of one or more months TIGF accepts any request for returning Firm Capacity of one or more months held by the shipper. The request must be ed to backoffice-atr@tigf.fr ten (10) calendar days before the beginning of the monthly capacity subscriptions marketing period. The request for returning Firm Capacity specifies the interconnection point in question, the quantity and the start and end dates, and must be made by a person duly empowered for the purpose. Requests for return of capacity will be handled in the order in which they are received. A capacity return request does not discharge the Shipper of its rights and obligations under this Contract. The portion of the capacity covered by the return request that has been allocated to shippers marketing Firm Monthly Capacities is deemed a Returned Capacity. The Shipper assigns all its rights and obligations regarding the Returned Capacity, apart from the obligation to pay the price differential, if positive, between the amount owing by the Shipper for this Returned Capacity if it had not been returned and the amount owing by shippers in respect of this Returned Capacity. Where applicable, TIGF informs the Shipper three (3) Business Days after the end of the sales period for Returned Capacities. The Shipper retains its rights and obligations under the Contract until the capacity has been allocated. 3.2 At the storage interconnection points (PITS) Rule 1 A Shipper can benefit from Firm capacities that are: annual, multi-year and daily; according to the provisions shown below. Rule 2 TIGF automatically allocates the annual capacity at the PITS-E (respectively at the PITS-L) that matches the maximum withdrawal (or injection) capacity of the Storage Contract held by the Shipper. These capacities are modified with each modification of the Storage Contract. Rule 3 For capacities whose frequency is daily that start on day D, subscription requests must be made between the twenty-first (21) day of Month M-1 and noon (12.00) on Day D-1. Rule 4 Pursuant to arrangements made during CRE deliberations on 29 January 2014, quarterly and monthly capacities can be sold on the initiative of the storage facility operator. 3.3 At the exit points (PS) Natural gas transport contract Appendix B.1: Rules for subscription and allocation on the Main Grid 5

6 The rate rules for the usage of the TIGF grid indicate that: Each exit zone from the main TIGF grid is defined by all of the delivery points attached to it. For each Shipper and in each exit zone, the firm annual subscription for exit capacity from the main grid must be greater than or equal to the sum of the firm annual subscriptions for delivery capacity in this exit zone. Consequently: Rule 1 At the Exit Point, TIGF automatically allocates, to each Shipper, a quantity equal to the sum of the firm subscriptions made by the Shipper or sold to the Shipper for an annual or longer period at the Delivery Points attached to this Exit Point. Rule 2 For a PITD (Transmission/Distribution Interconnection Point): If the firm annual subscription is modified at a Transmission/Distribution Interconnection Point, the firm subscription at the PS to which this Transmission/Distribution Interconnection Point is attached will be automatically adjusted by TIGF, in compliance with the new firm subscription at this Transmission/Distribution Interconnection Point. For a firm monthly subscription at the Transmission/Distribution Interconnection Point, the firm monthly subscription at the PS to which this Transmission/Distribution Interconnection Point is attached will be automatically adjusted by TIGF, in compliance with the new firm monthly subscription at this Transmission/Distribution Interconnection Point. For a PIC: (Consumer Interconnection Point) If the firm annual subscription is modified at a PIC, the firm subscription at the PS to which this PIC is attached will be automatically adjusted by TIGF, in compliance with the new firm subscription at this PIC. Rule 3 In case of a firm monthly or daily subscription at the PLs, the firm subscription at the PSs must be made by the Shipper on TETRA in compliance with the new firm subscription at the PL, in keeping with the time frames indicated in the present paragraph s rule 6. Rule 4 If it wishes to obtain capacities in addition to the ones anticipated in rule 1, a Shipper can request a subscription of capacities at the PS according to the time frames indicated in rule 6 in this paragraph. Rule 5 Firm: annual, multi-year, monthly and daily; Interruptible: daily No interruptible annual or monthly capacity can be marketed at the main grid exit point. Rule 6 For capacities for which the frequency is: Annual or multi-year starting on the 1st day of a month M of year N, subscription requests must be made no later than the 20 th of month M-1. Quarterly starting on the 1 st day of a month M, subscription requests must be made no later than the 20 th of month M-1. Natural gas transport contract Appendix B.1: Rules for subscription and allocation on the Main Grid 6

7 Monthly starting on the first day of month M, subscription requests must be made between the 1 st and the 20 th day of month M-1 inclusive. Daily starting on day D, subscription requests must be made between the twenty-first (21) day of Month M-1 and 2.30 PM on Day D SECONDARY CAPACITIES MARKET TIGF offers Shippers that have signed a Transport Contract with TIGF the option of buying or selling multi-year, annual, multi-season, seasonal, quarterly, monthly and daily capacities, on the secondary market at the PITTEs and PITTLs (excluding the Transport/Storage Interconnection Point). The Shipper can sell subscribed capacities to another Shipper having a valid Transport Contract, subject to the following provisions: A. Usage right, B. Complete sale For Complete Sales, transactions are signed on a bilateral basis (private contract), before the deadline. For Sales of Usage Rights, transactions are made unilaterally, but while so informing the counterparty. Capacities available for sale include Entry or Exit capacities, Firm or interruptible at the Network Interconnection Points (Pirineos PITT). The practical arrangements for selling capacities at the Pirineos PITT are describe in Appendix E.1 "Procedure for marketing capacities at the Pirineos virtual interconnection point". 4.1 Transfer arrangements Complete transfer When the same concerns complete or partial annual seasonal, quarterly or monthly subscriptions, via a complete number of calendar months, the sale is termed "complete": the TNO transfers the rights and obligations for the Subscribed Capacities to the acquiring Shipper, including the payment of the Price. As such, the acquiring Shipper will have to validate the sale request prepared by the transferor. For a complete sale, the transferring Shipper provides the TNO with a capacity sale request entered in TETRA, specifying: The Network Interconnection Point in question, The identity of the counterparty acquiring the capacity, The Daily Entry or Exit Capacity (MWh/d at 0 C) transferred, The starting and ending dates of the transfer, The Nature (Firm or interruptible) of the transferred capacity, The frequency of the transferred capacity (annual, seasonal, quarterly, monthly). Transactions are initiated by the transferring Shipper who enters its request in TETRA; the Shipper (assignee) and the Transmission Network Operator are so informed, the Shipper (assignee) must then either approve or refuse the transfer. Natural gas transport contract Appendix B.1: Rules for subscription and allocation on the Main Grid 7

8 Daily subscribed capacities cannot be the subject of a complete capacity sale Sale of the usage right A sale is said to relate to a usage right when the transfer of the assignor Shipper s capacity to the assignee Shipper does not result in the transfer of the Price s payment. Sales of usage right concern all frequencies and periods, except for complete annual transfers (annual capacity transferred for exactly one year). Usage right sales can therefore relate to the following capacities: 1. annual, one or more complete months or consecutive days, for a period of less than one year, 2. seasonal, for periods of one or more complete months or consecutive days, 3. quarterly, for exact periods of one or more quarters, or one or more complete months or consecutive days, 4. monthly, for a duration of one or several complete months or consecutive days, 5. daily, for a duration of one day or several consecutive days. For a usage right sale, the assignor Shipper uses TETRA to enter a capacity sale request, while stipulating: The Network Interconnection Point in question, The counterparty benefiting from the capacity, The Daily Entry or Exit Capacity (MWh/d at 0 C) transferred, The starting and ending dates, The Nature (Firm or interruptible) of the transferred capacity. The sale request submitted by the assignor Shipper will simply be declared to the assignee Shipper by the TNO, though it requires no validation by the latter. 4.2 Common arrangements The TNO undertakes to respond to a capacity sale request within three (3) business days of receipt thereof. Capacity sale requests, confirmation of the sales by the acquiring Shipper as well as responses from the TNO are made via the TNO s TETRA Internet site, and should the latter be unavailable, by or fax. Subject to a confirmation from the counterparty in the event of a complete sale, and within the established time frames, the TNO accepts capacity sale requests. At the Pirineos interconnection, a procedure common to TIGF and ENAGAS handles grouped transfers of capacities (see Appendix E.1 "Procedure for marketing capacities at the Pirineos virtual interconnection point"). 4.3 Time frame for carrying out a capacity exchange on the TIGF grid Natural gas transport contract Appendix B.1: Rules for subscription and allocation on the Main Grid 8

9 Until 1 PM on D-1 for an exchange relating to a single day D. Until 1 PM on D-5 for an exchange relating to any other period that begins on a day D of a month M. Here is a recap diagram of the types of sales per product: 5. LONG-TERM USE-IT-OR-LOSE-IT (LT-UIOLI) PRINCIPLE TIGF can implement a LT-UIOLI procedure, the purpose of which is to provide shippers with subscribed capacities unused by one or more shippers at the interconnection points. The LT-UIOLI procedure can be implemented if the following conditions are met: 1. For two successive periods of six (6) consecutive Months, starting on the first (1 st ) of October or the first (1 st ) of April, the Daily Scheduled Quantities of withdrawal (or delivery) for the Shipper at an Interconnection point are on average less than eighty percent (80%) of the Daily Entry (Exit) Capacity subscribed by the Shipper according to Interconnection point for a period greater than or equal to one Natural gas transport contract Appendix B.1: Rules for subscription and allocation on the Main Grid 9

10 year that has not been sold to another shipper under the Contract or returned pursuant to article above; 2. TIGF has not been able to satisfy at least one duly justified request from another shipper for an annual subscription for a Daily Entry (Exit) Capacity according to Network Interconnection Point. Further to a request from a shipper under the conditions set out in paragraph 2 above, and as provided for by paragraph 1 above, TIGF checks whether one or more shippers are likely to retrocede Daily Entry (Exit) Capacity according to Interconnection point. TIGF informs the Energy Regulatory Commission of the situation. If the Shipper is affected by the LT-UIOLI procedure, TIGF notifies to the Shipper concerned a maximum retrocession request for all or part of the Daily Entry (Exit) Capacity at the Interconnection point subscribed by the Shipper. The Shipper, if affected by the LT-UIOLI procedure, undertakes where applicable to justify under-use of its subscribed capacities within ten (10) Business Days of TIGF's notification of the maximum retrocession request. TIGF then forwards this justification to the Energy Regulatory Commission. Should the Energy Regulatory Commission decide to implement the LT-UIOLI procedure for the Shipper, TIGF then notifies to the Shipper a final retrocession request on the basis of the Energy Regulatory Commission's decision. The portion of the capacity covered by the final retrocession request that has been allocated to shippers marketing Firm Capacities at the Network Interconnection Point is deemed a Returned Capacity. The Shipper assigns all its rights and obligations regarding the Returned Capacity, apart from the obligation to pay the price differential, if positive, between the amount owing by the Shipper for this Returned Capacity if it had not been returned and the amount owing by shippers in respect of this Returned Capacity. Where applicable, TIGF informs the Shipper of the quantities of Returned Capacities three (3) Business Days after the end of the corresponding sales period. The Shipper retains its rights and obligations under the Contract until the capacity has been allocated. 6. USE IT AND BUY IT (UBI) PRINCIPLE As soon as the UBI system is in place, the following rules apply: Rule 1 The Use-It-and-Buy-It (UBI) offer allows a Shipper to request additional capacities over and above its subscriptions (firm and interruptible). These capacities can be allocated to it (in whole or in part) if another Shipper does not use all of its capacities on a given day. The UBI offer is available when at least 98% of the total firm capacity has been subscribed. The Shipper asks for this UBI capacity by means of notifications, by notifying over and above its rights: the difference between the notification and the subscribed capacity is considered to be a UBI request. Rule 2 The following points are concerned by the UBI offer: Entry points: Pirineos. Natural gas transport contract Appendix B.1: Rules for subscription and allocation on the Main Grid 10

11 Exit points: Pirineos. The UBI offer is only offered in the physical (or forward) direction of the flow. The UBI service does not exist for the opposite direction. The physical direction is determined by the algebraic sum of the notifications carried out at these points (the incoming notifications having a positive sign, and the outgoing nominations having a negative sign). Rule 3 Should no further firm daily capacity be available (including capacity reduction period), the capacities reserved by a Shipper for annual, seasonal and monthly subscriptions not notified the previous day can be allocated by TIGF to other Shippers present at this point and that have made a request for UBI capacities. This request is considered equal to the difference between the Shipper s actual notification and the rights that it holds. Rule 4 The Shipper originally holding the capacity retains the right to carry out re-notifications that have priority relative to the newly allocated capacity. Consequently, the UBI allocated capacities are interruptible. Rule 5 Only notifications in excess of rights that are made between 2 PM the day before day D and 3 AM on day D are deemed UBI capacity requests for day D. Should it not be possible to completely deliver the UBI requested capacities, the capacities are allocated in proportion to the requests received. Rule 6 When UBI requests are handled on D-1 for D, the capacities are attributed in proportion to the requests. With each re-notification/rescheduling cycle, each Shipper can recoup its subscribed capacity. Consequently, on D-1 a Shipper cannot be guaranteed a UBI capacity it has requested for day D. Rule 7 When UBI requests are handled intra-d, the following principle applies: a Shipper can recoup its reserved capacity, within the limits of the intra-d UBI capacities already allocated. The UBI capacities already allocated on a proportional basis are taken into account. Once day D begins, A Shipper that has made a notification greater than its subscribed capacity (and has therefore become a UBI requester ) may not make an intra-day re-notification of less than its subscribed capacity (which would then make it a UBI assignor ) Symmetrically, a Shipper that is a UBI assignor cannot become a UBI requester : it cannot carry out an intra-day re-notification greater than its subscribed capacity. Rule 8 The available UBI capacities are published on the site every day. Quantified example 1: The Shipper has not subscribed any capacity at the point in question. Natural gas transport contract Appendix B.1: Rules for subscription and allocation on the Main Grid 11

12 A Shipper requests 240 MWh/d of UBI capacity at 6 AM in intra-d. In the 1st hour it is assigned 1/24 x 240 MWh/d = 10 MWh/d. If it maintains its request for 240 MWh/d for 8 hours, at 2 pm it will already have used 80 MWh/d of UBI capacity:. If at 2 pm it requests MWh/d, it will already have used 80 MWh/d of UBI capacity: its allocated UBI capacity cannot drop below the UBI capacity that has been used, prorated to past hours. Quantified example 2: The Shipper has subscribed for 100 MWh/d of capacity at the point in question. For the first 8 hours of the day, the Shipper notifies 124 MWh/d. It thus requests 24 MWh/d of UBI capacity. It is therefore allocated 24/24 = 1 MWh/d of UBI capacity for each hour that has passed. At 2 PM, it will therefore already have used 8 MWh/D of UBI capacity. At 2 PM, it notifies 80 MWh/d, which is therefore below its subscribed capacity. It is then potentially an UBI assignor. However, its used UBI capacity is still 8 MWh/d and accordingly its assigned UBI capacity is 8 MWh/d. This is the value recorded on its capacity form. Natural gas transport contract Appendix B.1: Rules for subscription and allocation on the Main Grid 12

APPENDIX B.1: RULES FOR SUBSCRIPTION AND ALLOCATION ON THE MAIN NETWORK. Version dated [01/11/2017]

APPENDIX B.1: RULES FOR SUBSCRIPTION AND ALLOCATION ON THE MAIN NETWORK. Version dated [01/11/2017] APPENDIX B.1: RULES FOR SUBSCRIPTION AND ALLOCATION ON THE MAIN NETWORK Version dated [01/11/2017] 1 Description of the capacity offer on the main network The daily capacities marketed on the main network

More information

APPENDIX B 2: RULES FOR SUBSCRIPTION AND ALLOCATION ON THE REGIONAL NETWORK. Version dated [01/04/2018]

APPENDIX B 2: RULES FOR SUBSCRIPTION AND ALLOCATION ON THE REGIONAL NETWORK. Version dated [01/04/2018] APPENDIX B 2: RULES FOR SUBSCRIPTION AND ALLOCATION ON THE REGIONAL NETWORK Version dated [01/04/2018] 1 Table of Content 1 Table of Content... 2 2 Description of the capacity offer on the Regional Network...

More information

GRTGAZ NETWORK TRANSMISSION CONTRACT

GRTGAZ NETWORK TRANSMISSION CONTRACT GRTGAZ NETWORK TRANSMISSION CONTRACT SECTION B UPSTREAM NETWORK VERSION APPLICABLE AS OF 1ST APRIL 2016 English translation for information. Disclaimer The present translation is not binding and is provided

More information

TRANSMISSION CONTRACT ON THE NATURAL GAS TRANSMISSION SYSTEM

TRANSMISSION CONTRACT ON THE NATURAL GAS TRANSMISSION SYSTEM TRANSMISSION CONTRACT ON THE NATURAL GAS TRANSMISSION SYSTEM Appendix 1 GENERAL TERMS AND CONDITIONS Version of June 1, 2010 NON BINDING The English translation of the General Terms and Conditions of the

More information

Natural Gas Storage Contract APPENDIX D Rules for the allocation of storage capacities

Natural Gas Storage Contract APPENDIX D Rules for the allocation of storage capacities Natural Gas Storage Contract APPENDIX D Rules for the allocation of storage capacities Version approved by the Direction Générale de l Energie et du Climat (DGEC) on 23 January 2017 The allocation rules,

More information

Interconnector (UK) Limited IUK Access Code

Interconnector (UK) Limited IUK Access Code Interconnector (UK) Limited IUK Access Code Issue 2 May 2015 subject to NRA approval Contents SECTION A INTRODUCTION... 1 1. IUK Access Code... 1 2. Capacity... 1 3. Nominations and Matching Procedures...

More information

Interconnector (UK) Limited. IUK Access Code

Interconnector (UK) Limited. IUK Access Code Interconnector (UK) Limited IUK Access Code Issue 5 March 2018 Contents SECTION A INTRODUCTION... 1 1. IUK Access Code... 1 2. Transportation Services... 1 3. Nominations and Matching Procedures... 1 4.

More information

APPENDIX C Storage Operational Conditions

APPENDIX C Storage Operational Conditions Natural Gas Storage Contract APPENDIX C Storage Operational Conditions Version of 1 April 2017 CONTENTS ARTICLE 1. PURPOSE OF THE APPENDIX... 3 ARTICLE 2. EXCHANGES OF INFORMATION: TRANSPORT/STORAGE EQUIVALENCY...

More information

where implicit capacity allocation methods are applied, national regulatory authorities may decide not to apply Articles 8 to 37.

where implicit capacity allocation methods are applied, national regulatory authorities may decide not to apply Articles 8 to 37. System Operator's METHODOLOGY OF GAS TRANSMISSION CAPACITY ALLOCATION AND CONGESTION MANAGEMENT PROCEDURE AND STANDARD TERMS FOR ACCESSING THE CROSS-BORDER INFRASTRUCTURE 30 th June 2017 1. General provisions...

More information

Version dated [01/11/2017] SPECIAL TERMS

Version dated [01/11/2017] SPECIAL TERMS Version dated [01/11/2017] SPECIAL TERMS 1 INTRODUCTION A. The Transmission System Operator has a network of pipelines on French territory for carrying natural gas; B. The Shipper has asked the TSO to

More information

Find out more about. Capacity subscriptions at Obergailbach, Virtualys, Taisnières B and Oltingue PIR

Find out more about. Capacity subscriptions at Obergailbach, Virtualys, Taisnières B and Oltingue PIR Find out more about Capacity subscriptions at Obergailbach, Virtualys, Taisnières B and Oltingue PIR + + You are active on GRTgaz upstream network and want to subscribe for capacity at Network Interconnection

More information

APPENDIX E.1: PROCEDURE FOR THE MARKETING OF CAPACITIES AT THE PIRINEOS VIRTUAL INTERCONNECTION POINT

APPENDIX E.1: PROCEDURE FOR THE MARKETING OF CAPACITIES AT THE PIRINEOS VIRTUAL INTERCONNECTION POINT APPENDIX E.1: PROCEDURE FOR THE MARKETING OF CAPACITIES AT THE PIRINEOS VIRTUAL INTERCONNECTION POINT Version dated [01/04/2017] NOTICE The purpose of this document is to describe in detail the procedures

More information

2 nd Technical Workshop: Gas Market Design and Natural Gas Transmission Grid Codes

2 nd Technical Workshop: Gas Market Design and Natural Gas Transmission Grid Codes 2 nd Technical Workshop: Gas Market Design and Natural Gas Transmission Grid Codes Practices for Grid Code Harmonization Examining Capacity Allocation and Congestion Management Fotis Thomaidis Partner,

More information

Shippers' guide to maintenance-related capacity reductions

Shippers' guide to maintenance-related capacity reductions Shippers' guide to maintenance-related capacity reductions Table of contents 1. Introduction... 4 2. Chosen principles... 5 2.1 Summary of the principles... 5 2.2 Calculating the reduction rates due to

More information

GRTGAZ NETWORK TRANSMISSION CONTRACT

GRTGAZ NETWORK TRANSMISSION CONTRACT Disclaimer The present translation is not binding and is provided by GRTgaz exclusively for information purposes. GRTgaz disclaims any warranty of any kind as to the accuracy and completeness of the present

More information

Exhibit G to the General Terms and Conditions Forward Flow November 2015

Exhibit G to the General Terms and Conditions Forward Flow November 2015 CAM and CMP implementation and general rules Introduction In this Exhibit G BBL Company sets out the conditions following from the implementation of CAM and CMP. This exhibit G is not exhaustive because

More information

CAMG Gestion Opérationnelle des Contrats Tariff Operational rules

CAMG Gestion Opérationnelle des Contrats Tariff Operational rules 29 Tariff Operational rules A simplified transmission system and new services for shippers New point codes North-South link New Short-Term Use-It-or-Lose-It service (UIOLI 29) -2- A simplified transmission

More information

AB AMBER GRID RULES FOR ACCESS TO THE NATURAL GAS TRANSMISSION SYSTEM

AB AMBER GRID RULES FOR ACCESS TO THE NATURAL GAS TRANSMISSION SYSTEM TRANSMISSION SYSTEM OPERATOR AB AMBER GRID AB AMBER GRID RULES FOR ACCESS TO THE NATURAL GAS TRANSMISSION SYSTEM Version 3.0 Vilnius, 2015 TABLE OF CONTENTS 1. GENERAL PROVISIONS... 3 2. DEFINITIONS AND

More information

UNOFFICIAL TRANSLATION

UNOFFICIAL TRANSLATION UNOFFICIAL TRANSLATION REPUBLIC OF LATVIA PUBLIC UTILITIES COMMISSION COUNCIL RESOLUTION Riga, 13.04.2017 No. 1/16 (Minutes No. 15, para. 4) Rules of Use of the Natural Gas Transmission System 1. The regulations

More information

UNOFFICIAL TRANSLATION

UNOFFICIAL TRANSLATION UNOFFICIAL TRANSLATION REPUBLIC OF LATVIA PUBLIC UTILITIES COMMISSION COUNCIL RESOLUTION Riga, 13.04.2017 No. 1/16 (Minutes No. 15, para. 4) Rules of Use of the Natural Gas Transmission System 1. The regulations

More information

Exhibit G to the General Terms and Conditions Forward Flow as of 2018

Exhibit G to the General Terms and Conditions Forward Flow as of 2018 CAM and CMP implementation and general rules General provisions Terms defined in the Conditions shall have the same meaning when used herein. This Exhibit G shall form part of the Conditions as amended

More information

PUBLIC CONSULTATION INTERCONNECTION AGREEMENT VIP PIRINEOS

PUBLIC CONSULTATION INTERCONNECTION AGREEMENT VIP PIRINEOS PUBLIC CONSULTATION INTERCONNECTION AGREEMENT VIP PIRINEOS IN: VIP PIRINEOS BETWEEN: TIGF, AND ENAGAS TRANSPORTE, S.A.U. AND ENAGAS GTS, S.A.U. 1 This Interconnection Agreement is made on December 19 th,

More information

Introduction of Entry Capacity to Northern Ireland Transitional Arrangements

Introduction of Entry Capacity to Northern Ireland Transitional Arrangements Introduction of Entry Capacity to Northern Ireland Transitional Arrangements Business Rules Revised Post-Consultation Version 1.1 13 th October 2014 Contents 1. Introduction: Background and Purpose...

More information

Coordinated implementation of the Network Code on Capacity Allocation Mechanisms. Information Memorandum

Coordinated implementation of the Network Code on Capacity Allocation Mechanisms. Information Memorandum Coordinated implementation of the Network Code on Capacity Allocation Information Memorandum February 2014 INDEX Disclaimer... 4 1 Background... 5 2 Auctions... 6 2.1 2014 auctions... 6 2.2 2015 auctions

More information

Decision. on 1 st April Decision of 30 October 2014 forming a ruling on the changes to the ATRT5 tariff concerning the interim measures

Decision. on 1 st April Decision of 30 October 2014 forming a ruling on the changes to the ATRT5 tariff concerning the interim measures Decision Deliberation of the French Regulatory Commission of Energy of 19 March 2015 deciding on the evolution of the tariffs for the use of natural gas transmission networks as of 1 April 2015 Present

More information

Exhibit G to the General Terms and Conditions Forward Flow as of 2018

Exhibit G to the General Terms and Conditions Forward Flow as of 2018 CAM and CMP implementation and general rules General provisions Terms defined in the Conditions shall have the same meaning when used herein. This Exhibit G shall form part of the Conditions as amended

More information

ENTSOG s Capacity conversion model

ENTSOG s Capacity conversion model 2017-07-24 ENTSOG AISBL; Av. de Cortenbergh 100, 1000-Brussels; Tel: +32 2 894 5100; Fax: +32 2 894 5101; info@entsog.eu, www.entsog.eu, VAT No. BE0822 653 040 Background On October 13 th, 2016 the amendment

More information

SASOL GAS NETWORK CODE FOR THE TRANSMISSION SYSTEM

SASOL GAS NETWORK CODE FOR THE TRANSMISSION SYSTEM SASOL GAS NETWORK CODE FOR THE TRANSMISSION SYSTEM Table of Contents Section A: INTRODUCTION... A-1 1 Network Code A-1 2 System Definition A-1 2.1 Definitions... A-1 2.2 System Points... A-2 Section B:

More information

CODE OPERATIONNEL DE RESEAU TRANSMISSION

CODE OPERATIONNEL DE RESEAU TRANSMISSION CODE OPERATIONNEL DE RESEAU TRANSMISSION PART E1.3 SCHEDULING EXCEPT ON TITLE TRANSFERT POINTS Disclaimer The present translation is not binding and proposed by GRTgaz exclusively for information purposes.

More information

Entry Point Registrations

Entry Point Registrations Entry Point Registrations Business Rules Revised Post-Consultation Version 1.1 13 th October 2014 Contents 1. Introduction... 3 2. Relevant Context... 3 3. Entry Point Registrations - Principles... 4 4.

More information

Interconnector (UK) Limited

Interconnector (UK) Limited Interconnector (UK) Limited IUK Access Code Consultation Version October 2013 Contents SECTION A TRANSPORTATION SYSTEM GENERAL PRINCIPLES 1. Transportation... 1 SECTION B CAPACITY 1. Transportation System

More information

EU Gas Balancing Code - Daily Nominations at Interconnection Points (IP)

EU Gas Balancing Code - Daily Nominations at Interconnection Points (IP) UNC MODIFICATION PROPOSAL 0493 EU Gas Balancing Code - Daily Nominations at Interconnection Points (IP) COMMERCIAL BUSINESS RULES Text in red [BC 12(3)] [INT 12(3)] Key to format convention is reference

More information

to the general terms and conditions for access to the natural gas storage facilities operated by innogy Gas Storage NWE GmbH (igsnwe)

to the general terms and conditions for access to the natural gas storage facilities operated by innogy Gas Storage NWE GmbH (igsnwe) Annex Balancing, Version of 01/12/2016 Annex: Balancing to the general terms and conditions for access to the natural gas storage facilities operated by innogy Gas Storage NWE GmbH (igsnwe) 1 Allocation

More information

8.1. GENERAL RULES OF CAPACITY BOOKING

8.1. GENERAL RULES OF CAPACITY BOOKING 8.1. GENERAL RULES OF CAPACITY BOOKING (a) Pursuant to the provisions of the Gas Supply Act and the Implementation Decree the free capacities of the natural gas network may and shall be offered to network

More information

Framework Guidelines on Capacity Allocation Mechanisms for the European Gas Transmission Network FG-2011-G August 2011

Framework Guidelines on Capacity Allocation Mechanisms for the European Gas Transmission Network FG-2011-G August 2011 Framework Guidelines on Capacity Allocation Mechanisms for the European Gas Transmission Network FG-2011-G-001 3 August 2011 Agency for the Cooperation of Energy Regulators Trg Republike 3 1000 Ljubljana

More information

Applicable TSO Terms for Use of the PRISMA Capacity Platform. 01 November 2015

Applicable TSO Terms for Use of the PRISMA Capacity Platform. 01 November 2015 Applicable TSO Terms for Use of the PRISMA Capacity Platform 01 November 2015 TERMS APPLICABLE FOR BAYERNETS GMBH, FLUXYS DEUTSCHLAND GMBH, FLUXYS TENP GMBH, GASTRANSPORT NORD GMBH, GASCADE GASTRANSPORT

More information

Exhibit G to the General Terms and Conditions Forward Flow as of 2018November 2015

Exhibit G to the General Terms and Conditions Forward Flow as of 2018November 2015 CAM and CMP implementation and general rules General provisions Terms defined in the Conditions shall have the same meaning when used herein. This Exhibit G shall form part of the Conditions as amended

More information

Winter Outlook

Winter Outlook Winter Outlook 2016-2017 GRTgaz SA and TIGF SA may not be held liable for direct or indirect prejudice of any type that results from the use or processing of the information contained herein, in particular

More information

CODE OPERATIONNEL DE RESEAU TRANSMISSION

CODE OPERATIONNEL DE RESEAU TRANSMISSION CODE OPERATIONNEL DE RESEAU TRANSMISSION PART B3.1 CONDITIONS OF CAPACITY AVAILABILITY AT ENTRY/EXIT POINTS OF GRTGAZ TRANSMISSION SYSTEM EXCLUDING MAINTENANCE PERIODS Disclaimer The present translation

More information

EU Network Code Implementation Project

EU Network Code Implementation Project EU Network Code Implementation Project Frequently Asked Questions Version 3.0 1 Contents 1. Introduction... 3 1.1. New Questions... 3 2. General... 3 2.1. CAM Network Code: Background and Scope... 3 2.2.

More information

Energie-Control Austria Executive Board Ordinance on Provisions for the Gas Market Model (Gas Market Model Ordinance 2012) Title 1 Principles

Energie-Control Austria Executive Board Ordinance on Provisions for the Gas Market Model (Gas Market Model Ordinance 2012) Title 1 Principles Energie-Control Austria Executive Board Ordinance on Provisions for the Gas Market Model (Gas Market Model Ordinance 2012) In exercise of section 41 Gaswirtschaftsgesetz (Natural Gas Act) 2011, BGBl. (Federal

More information

PETRONAS GAS BERHAD NETWORK CODE FOR PENINSULAR GAS UTILISATION TRANSMISSION SYSTEM

PETRONAS GAS BERHAD NETWORK CODE FOR PENINSULAR GAS UTILISATION TRANSMISSION SYSTEM PETRONAS GAS BERHAD NETWORK CODE FOR PENINSULAR GAS UTILISATION TRANSMISSION SYSTEM 2014 PETRONAS GAS BERHAD All rights reserved. No part of this document may be reproduced, stored in a retrieval system

More information

Financial Transmission Rights

Financial Transmission Rights PJM Manual 06 Financial Transmission Rights Revision: 12 Effective Date: July 1, 2009 Prepared by Market Simulation Department PJM 2009 PJM Revision 05, Effective Date: 12/30/03 iii Table of Contents PJM

More information

Winter Outlook

Winter Outlook Winter Outlook 2016-2017 GRTgaz SA and TIGF SA may not be held liable for direct or indirect prejudice of any type that should result from the use or processing of any of the information herein, in particular

More information

Official Journal of the European Union. (Non-legislative acts) REGULATIONS

Official Journal of the European Union. (Non-legislative acts) REGULATIONS 17.3.2017 L 72/1 II (Non-legislative acts) REGULATIONS COMMISSION REGULATION (EU) 2017/459 of 16 March 2017 establishing a network code on capacity allocation mechanisms in gas transmission systems and

More information

Appendix 1 Entry/Exit Contract Terms & Conditions (entry/exit system) Section 1 Conclusion of contract

Appendix 1 Entry/Exit Contract Terms & Conditions (entry/exit system) Section 1 Conclusion of contract Appendix 1: Entry/Exit General Terms & Conditions (entry/exit system) The document is available in German and English. Only the original German version is legally binding. Section 1 Conclusion of contract

More information

Locational Spread: a market mechanism

Locational Spread: a market mechanism Locational Spread: a market mechanism Context The locational spread arises from the works with shippers during the construction of the Single Marketplace, within the Concertation Gaz working group. This

More information

Network Code. on Capacity Allocation Mechanisms

Network Code. on Capacity Allocation Mechanisms 6 March 2012 Network Code on Capacity Allocation Mechanisms An ENTSOG Network Code for ACER review and Comitology Procedure This document constitutes the Capacity Allocation Mechanisms Network Code developed

More information

Appendix 1: General Terms & Conditions for Entry/Exit Contracts (entry/exit sys- tem) Contents

Appendix 1: General Terms & Conditions for Entry/Exit Contracts (entry/exit sys- tem) Contents Contents Appendix 1: General Terms & Conditions for Entry/Exit Contracts (entry/exit system) 1 Section 1 Conclusion of contract 3 Section 2 Definitions of terms 4 Section 2a Admission to the primary capacity

More information

Pricelist for Services Provided by POZAGAS a.s. and Terms and Conditions of Prices Application

Pricelist for Services Provided by POZAGAS a.s. and Terms and Conditions of Prices Application Pricelist for Services Provided by POZAGAS a.s. and Terms and Effectiveness: from 6 February 2017 Storage Operator: POZAGAS a.s. Malé námestie 1 901 01 Malacky Slovak Republic Company ID: 31 435 688 Recorded

More information

Virtual Workshop on PJM ARR and FTR Market 2017/2018

Virtual Workshop on PJM ARR and FTR Market 2017/2018 Virtual Workshop on PJM ARR and FTR Market 2017/2018 PJM State & Member Training Dept. Webex February 10, 2017 PJM 2017 Disclaimer: PJM has made all efforts possible to accurately document all information

More information

Gas Transmission Charging Methodology Statement. Gas Year 2016/17

Gas Transmission Charging Methodology Statement. Gas Year 2016/17 Gas Transmission Charging Methodology Statement Gas Year 2016/17 Contents 1. Introduction... 3 Part A - POSTALISED CHARGES... 6 2. Process for setting Forecast Postalised Charges... 6 3. Calculation of

More information

Gas Transmission Charging Methodology Statement. Gas Year 2017/18

Gas Transmission Charging Methodology Statement. Gas Year 2017/18 Gas Transmission Charging Methodology Statement Gas Year 2017/18 Contents 1. Introduction... 3 Part A - POSTALISED CHARGES... 6 2. Process for setting Forecast Postalised Charges... 6 3. Calculation of

More information

UNC 0616: Capacity Conversion Mechanism for Interconnection Points. UNC Modification. 01 Modification. 02 Workgroup Report

UNC 0616: Capacity Conversion Mechanism for Interconnection Points. UNC Modification. 01 Modification. 02 Workgroup Report UNC Modification UNC 0616: Capacity Conversion Mechanism for Interconnection Points At what stage is this document in the process? 01 Modification 02 Workgroup Report 03 04 Draft Modification Report Final

More information

NATURAL GAS TRANSPORTATION SERVICES PROVIDED BY IUK BETWEEN GB AND BELGIUM

NATURAL GAS TRANSPORTATION SERVICES PROVIDED BY IUK BETWEEN GB AND BELGIUM NATURAL GAS TRANSPORTATION SERVICES PROVIDED BY IUK BETWEEN GB AND BELGIUM Issue 5 March 2018 www.interconnector.com DISCLAIMER This IUK Access Agreement Summary ( IAAS ) has been prepared by Interconnector

More information

APPENDIX D TO GAS TRANSPORTATION TARIFF OF NOVA GAS TRANSMISSION LTD. TERMS AND CONDITIONS RESPECTING CUSTOMER S INVENTORIES AND RELATED MATTERS

APPENDIX D TO GAS TRANSPORTATION TARIFF OF NOVA GAS TRANSMISSION LTD. TERMS AND CONDITIONS RESPECTING CUSTOMER S INVENTORIES AND RELATED MATTERS NOVA Gas Transmission Ltd. APPENDIX D TO GAS TRANSPORTATION TARIFF OF NOVA GAS TRANSMISSION LTD. TERMS AND CONDITIONS RESPECTING CUSTOMER S INVENTORIES AND RELATED MATTERS NOVA Gas Transmission Ltd. Page

More information

Relevant changes will be made to corresponding sections of OA and RAA.

Relevant changes will be made to corresponding sections of OA and RAA. PJM Interconnection - Intra-PJM Tariffs - OPEN ACCESS TRANSMISSION TARIFF PJM OPEN ACCESS TRANSMISSION TARIFF Relevant changes will be made to corresponding sections of OA and RAA. Effective Date: 9/17/2010

More information

Implementation of the Balancing Network Code: an overview of TSOs main challenges

Implementation of the Balancing Network Code: an overview of TSOs main challenges Implementation of Balancing Network Code 20 November 2013 Rev 1 Implementation of the Balancing Network Code: an overview of TSOs main challenges ENTSOG AISBL; Av. de Cortenbergh 100, 1000-Brussels; Tel:

More information

Description of the nature and purpose of the modification

Description of the nature and purpose of the modification 160 th January 2014 Transportation Network Code Proposed Modifications No. 12 Congestion Management Procedures Final Modification Report BGE (NI) ( The Transporter ) has prepared this report in accordance

More information

ELECTRONIC COMMERCE SERVICE GENERAL TERMS AND CONDITIONS

ELECTRONIC COMMERCE SERVICE GENERAL TERMS AND CONDITIONS ELECTRONIC COMMERCE SERVICE GENERAL TERMS AND CONDITIONS 1. Company data: Name: Magyar Posta Zártkörűen Működő Részvénytársaság Registered office: 1138 Budapest, Dunavirág u. 2-6. Trade register no.: Cg.

More information

Ellund capacity. - Creating new capacity at Ellund (DE) Maja Klejs Pedersen and Poul Johannes Jacobsen. 11 December 2014 User Group 1

Ellund capacity. - Creating new capacity at Ellund (DE) Maja Klejs Pedersen and Poul Johannes Jacobsen. 11 December 2014 User Group 1 Ellund capacity - Creating new capacity at Ellund (DE) Maja Klejs Pedersen and Poul Johannes Jacobsen 11 December 2014 User Group 1 Capacity maximisation CAM Article 6 Energinet.dk sees two options We

More information

CAPACITY BOOKING... 1 PART I - REQUIREMENTS FOR ACCESS TO THE TRANSPORTATION SERVICE ) REQUIREMENTS... 5

CAPACITY BOOKING... 1 PART I - REQUIREMENTS FOR ACCESS TO THE TRANSPORTATION SERVICE ) REQUIREMENTS... 5 CAPACITY BOOKING CAPACITY BOOKING... 1 PART I - REQUIREMENTS FOR ACCESS TO THE TRANSPORTATION SERVICE... 5 1) REQUIREMENTS... 5 1.1) REQUIREMENTS IN ACCORDANCE WITH RESOLUTION NO. 137/02... 5 1.1.1) Possession

More information

Operating Agreement. [contractlegalname] under the. between. [buyerlegalname] and [ENTITY] Version [docversion] Status: [docstatus]

Operating Agreement. [contractlegalname] under the. between. [buyerlegalname] and [ENTITY] Version [docversion] Status: [docstatus] Preamble Operating Agreement under the between [buyerlegalname] and [ENTITY] Version [docversion] Status: [docstatus] [docreleasedate] Preamble Preamble This Operating Agreement is made [oadayofweek],

More information

FERC GAS TARIFF FIRST REVISED VOLUME NO. 1. (Superseding Original Volume No. 1) SOUTHERN STAR CENTRAL GAS PIPELINE, INC.

FERC GAS TARIFF FIRST REVISED VOLUME NO. 1. (Superseding Original Volume No. 1) SOUTHERN STAR CENTRAL GAS PIPELINE, INC. FERC Gas Tariff FERC GAS TARIFF FIRST REVISED VOLUME NO. 1 ( Original Volume No. 1) Of SOUTHERN STAR CENTRAL GAS PIPELINE, INC. Filed With FEDERAL ENERGY REGULATORY COMMISSION Communications Covering Rates

More information

BOOKING MANUAL. Valid from 1 January 2016

BOOKING MANUAL. Valid from 1 January 2016 BOOKING MANUAL Valid from 1 January 2016 Booking Manual Page 1 of 14 TABLE OF CONTENTS 1 APPLICABILITY AND DEFINITIONS... 3 1.1 Applicability... 3 1.2 Definitions... 3 2 QUALIFIED NEED PROCEDURE... 4 2.1

More information

BOOKING MANUAL. Valid from 1 October 2017

BOOKING MANUAL. Valid from 1 October 2017 BOOKING MANUAL Valid from 1 October 2017 Booking Manual Page 1 of 15 TABLE OF CONTENTS 1 October 2017 1 APPLICABILITY AND DEFINITIONS... 3 1.1 Applicability... 3 1.2 Definitions... 3 2 QUALIFIED NEED PROCEDURE...

More information

CRE consultation on the implementation of regulated access to underground gas storage in France

CRE consultation on the implementation of regulated access to underground gas storage in France CRE consultation on the implementation of regulated access to underground gas storage in France n EFET response 23 January 2018 The European Federation of Energy Traders (EFET) thanks CRE for the opportunity

More information

Fluxys natural gas transport services in Belgium Indicative Conditions & Tariffs

Fluxys natural gas transport services in Belgium Indicative Conditions & Tariffs Fluxys natural gas transport services in Belgium Indicative Conditions & Tariffs Page 1 of 51 Contents 1. Introduction 4 1.1 Natural gas transport services in Belgium: scope 4 1.2 Regulated tariffs 4 1.3

More information

ERGEG Guidelines for Good Practice on Open Season Procedures (GGPOS) Ref: C06-GWG-29-05c 21 May 2007

ERGEG Guidelines for Good Practice on Open Season Procedures (GGPOS) Ref: C06-GWG-29-05c 21 May 2007 ERGEG Guidelines for Good Practice on Open Season Procedures (GGPOS) Ref: C06-GWG-29-05c 21 May 2007 European Regulators Group for Electricity and Gas Contact: Council of European Energy Regulators ASBL

More information

LNG TERMINALLING PROGRAMME

LNG TERMINALLING PROGRAMME LNG TERMINALLING PROGRAMME Based on Article 203 of the Royal Decree of 23 December 2010 on the Code of Conduct regarding access to natural gas transmission networks TABLE OF CONTENTS 1 INTRODUCTION...

More information

(proliferated in FLG II no 171/2012, as amended in 2016, FLG II no XXX/2016; as of 1 October 2016)

(proliferated in FLG II no 171/2012, as amended in 2016, FLG II no XXX/2016; as of 1 October 2016) Energie-Control Austria Executive Board Ordinance on Provisions for the Gas Market Model as amended in 2016 (2016 Gas Market Model Amendment Ordinance 2012) (proliferated in FLG II no 171/2012, as amended

More information

Locational Spread. For network congestion management Winter 17/18

Locational Spread. For network congestion management Winter 17/18 Locational Spread For network congestion management Winter 17/18 Contents Congestions General process of congestion management Locational Spread Call for Tenders Supplier s obligations Penalties Contractual

More information

Evolution of the ATM5 offer Proposals from Elengy and Fosmax LNG

Evolution of the ATM5 offer Proposals from Elengy and Fosmax LNG Evolution of the ATM5 offer Proposals from Elengy and Fosmax LNG Contents 1 Background... 2 2 Regasification services... 2 2.1 Core service... 2 2.2 Uniform option... 3 2.3 Spot service... 4 2.4 Management

More information

9.3.6 Maintenance Outage Planning. [The changes below will be effective July 1, 2018 so that CAISO can incorporate the outages in the

9.3.6 Maintenance Outage Planning. [The changes below will be effective July 1, 2018 so that CAISO can incorporate the outages in the 9.3.6 Maintenance Outage Planning [The changes below will be effective July 1, 2018 so that CAISO can incorporate the outages in the Formatted: Highlight CRR processes for 2019] 9.3.6.1 CRR Transmission

More information

ACCESS CODE FOR TRANSMISSION. Attachment B: Subscription & Allocation of Services

ACCESS CODE FOR TRANSMISSION. Attachment B: Subscription & Allocation of Services NON BINDING DOCUMENT FOR CONSULTATION PURPOSES ONLY ACCESS CODE FOR TRANSMISSION Attachment B: Subscription & Allocation of Services Based on version approved by CREG on 26 March 2015 1 of 72 Table of

More information

MISO MODULE B FERC Electric Tariff TRANSMISSION SERVICE MODULES Effective On: November 19, 2013

MISO MODULE B FERC Electric Tariff TRANSMISSION SERVICE MODULES Effective On: November 19, 2013 MISO MODULE B TRANSMISSION SERVICE MISO I INTRODUCTION The Transmission Provider shall provide Point-To-Point and Network Integration Transmission Service pursuant to the applicable terms and conditions

More information

RPO Roles and Responsibilities Customer Operations

RPO Roles and Responsibilities Customer Operations Customer Operations, BC Pipeline and Field Services RPO Roles and Responsibilities Customer Operations Prepared by: Gas Accounting Revision Tracking Date Created September 2002 Last Updated September 2015

More information

LNG TERMINALLING PROGRAMME.

LNG TERMINALLING PROGRAMME. LNG TERMINALLING PROGRAMME Based on Article 203 of the Royal Decree of 23 December 2010 on the Code of Conduct regarding access to natural gas transmission networks www.fluxys.com TABLE OF CONTENTS TABLE

More information

Present: Jean-François CARENCO, President, Catherine EDWIGE, Hélène GASSIN, Jean-Laurent LASTELLE et Jean-Pierre SOTURA, commissioners.

Present: Jean-François CARENCO, President, Catherine EDWIGE, Hélène GASSIN, Jean-Laurent LASTELLE et Jean-Pierre SOTURA, commissioners. DECISION NO. 2018-022 Deliberation of the French Energy Regulatory Commission of 7 February 2018 deciding on the evolution of the tariff for the use of GRTgaz and TIGF natural gas transmission networks

More information

FLUXYS STORAGE SERVICES : ISP - SC

FLUXYS STORAGE SERVICES : ISP - SC FLUXYS STORAGE SERVICES : ISP - SC Shippers Day CREG (June 22 th 2005) Indicative Storage Program (ISP( ISP) ISP LOENHOUT & PSP : INTRODUCTION Indicative Storage Program : first introduction (time frame

More information

Virtual Reverse Flow: at Interconnection Points. Implementing EU Regulations. Code Modification No. A064. Business Rules. Version 2.

Virtual Reverse Flow: at Interconnection Points. Implementing EU Regulations. Code Modification No. A064. Business Rules. Version 2. Virtual Reverse Flow: at Interconnection Points Implementing EU Regulations Code Modification No. A064 Business Rules 16 th January 2015 Version 2.0 i VERSION CONTROL Version Date Description 1.0 19 th

More information

Stakeholder Workshop II

Stakeholder Workshop II Brussels, 30 June 2015 Stakeholder Workshop II On issues related to bundling of capacities Brussels, 30 June 2015 Disclaimer This presentation does not reflect a commitment content wise nor time wise for

More information

LNG TERMINALLING PROGRAMME.

LNG TERMINALLING PROGRAMME. LNG TERMINALLING PROGRAMME Based on Article 203 of the Royal Decree of 23 December 2010 on the Code of Conduct regarding access to natural gas transmission networks www.fluxys.com TABLE OF CONTENTS 1 INTRODUCTION...

More information

ALLIANCE PIPELINE LIMITED PARTNERSHIP by its General Partner, ALLIANCE PIPELINE LTD. ( Alliance Canada or Alliance )

ALLIANCE PIPELINE LIMITED PARTNERSHIP by its General Partner, ALLIANCE PIPELINE LTD. ( Alliance Canada or Alliance ) ALLIANCE PIPELINE LIMITED PARTNERSHIP by its General Partner, ALLIANCE PIPELINE LTD. ( Alliance Canada or Alliance ) BINDING OPEN SEASON March 28 May 30, 2018 For: Capacity Expansion, Capacity Turn Backs,

More information

Table of Contents. Great Lakes Gas Transmission Limited Partnership. Third Revised Volume No. 1. Third Revised Volume No. 1 1 TABLE OF CONTENTS

Table of Contents. Great Lakes Gas Transmission Limited Partnership. Third Revised Volume No. 1. Third Revised Volume No. 1 1 TABLE OF CONTENTS Great Lakes Gas Transmission Limited Partnership Table of Contents 1 TABLE OF CONTENTS 2 PRELIMINARY STATEMENT 3 MAPS 4 STATEMENT OF RATES 4.1 Rate Schedules FT, LFT & EFT 4.2 Reserved for Future Use 4.3

More information

Virtual Reverse Flow: at Interconnection Points. Implementing EU Regulations. Code Modification No. A064. Business Rules. 17 th July Version 3.

Virtual Reverse Flow: at Interconnection Points. Implementing EU Regulations. Code Modification No. A064. Business Rules. 17 th July Version 3. Virtual Reverse Flow: at Interconnection Points Implementing EU Regulations Code Modification No. A064 Business Rules 17 th July 2015 Version 3.0 i VERSION CONTROL Version Date Description 1.0 19 th September

More information

National Grid Grain LNG Ltd. Third Party Access Arrangements. Guide for prospective Secondary Capacity customers 2017/18

National Grid Grain LNG Ltd. Third Party Access Arrangements. Guide for prospective Secondary Capacity customers 2017/18 National Grid Grain LNG Ltd Guide for prospective Secondary Capacity customers 2017/18 Disclaimer This document is produced as a guide only. The full terms and conditions for Third Party Access to the

More information

Vector Pipeline L.P. Original Sheet No. 30 FERC Gas Tariff First Revised Volume No. 1 v0.0.0 RATE SCHEDULE FT-1 FIRM TRANSPORTATION SERVICE

Vector Pipeline L.P. Original Sheet No. 30 FERC Gas Tariff First Revised Volume No. 1 v0.0.0 RATE SCHEDULE FT-1 FIRM TRANSPORTATION SERVICE Vector Pipeline L.P. Original Sheet No. 30 1. AVAILABILITY RATE SCHEDULE FT-1 FIRM TRANSPORTATION SERVICE This FT-1 Rate Schedule is available to any party (hereinafter called "Shipper"), for firm transportation

More information

AUCTION OF THE BUNDLED PRODUCT AT IP LASÓW

AUCTION OF THE BUNDLED PRODUCT AT IP LASÓW AUCTION OF THE BUNDLED PRODUCT AT IP LASÓW SHIPPE ERS MANUAL for information purposes only Warsaw/ Leipzig, March 2013 PAGE 1 / 15 CONTENTS: I. GENERAL INFORMATION... 3 II. DEFINITIONS... 3 III. REQUIREMENTS

More information

Northern Illinois Gas Company d/b/a Nicor Gas Company

Northern Illinois Gas Company d/b/a Nicor Gas Company Il1.C.C. No. 16 - Gas 6th Revised Sheet No.75.2 (Canceling 4th Sheet No.75.2, Effective January 18, 2002) Rider 15 Customer Select (Continued From Sheet No. 75.1) Customer may terminate their participation

More information

RATE SCHEDULE IT-S INTERRUPTIBLE - ACCESS TO STORAGE

RATE SCHEDULE IT-S INTERRUPTIBLE - ACCESS TO STORAGE Page 1 RATE SCHEDULE INTERRUPTIBLE - ACCESS TO STORAGE 1.0 DEFINITIONS 1.1 The capitalized terms used in this have the meanings attributed to them in the General Terms and Conditions of the Tariff unless

More information

GLOSSARY OF DEFINITIONS

GLOSSARY OF DEFINITIONS Disclaimer: This document representing the glossary of definitions has been prepared for information purposes only. While every effort has been made to attain complete accuracy herein, the user of this

More information

GENERAL TERMS AND CONDITIONS. for Storage Services ("GTCS") Uniper Energy Storage GmbH, Ruhrallee 80, Essen

GENERAL TERMS AND CONDITIONS. for Storage Services (GTCS) Uniper Energy Storage GmbH, Ruhrallee 80, Essen GENERAL TERMS AND CONDITIONS for Storage Services ("GTCS") of Uniper Energy Storage GmbH, Ruhrallee 80, 45136 Essen (hereinafter referred to as "Uniper Energy Storage") April 2017 General Terms and Conditions

More information

Reliability Pricing Model (RPM) DRAFT Business Rules

Reliability Pricing Model (RPM) DRAFT Business Rules Definition and Purpose of Reliability Pricing Model (RPM) 1. The purpose of the RPM is to develop a long term pricing signal for capacity resources and LSE obligations that is consistent with the PJM Regional

More information

UNC B5.2.2 stipulates that Users are permitted to propose a System Capacity Transfer at any point during a Day but no later than 04:00.

UNC B5.2.2 stipulates that Users are permitted to propose a System Capacity Transfer at any point during a Day but no later than 04:00. CODE MODIFICATION PROPOSAL No xxxx < Change System Capacity Transfers Notification Time Limit from 04:00 to 03:00> Version 0.1 Date: 02/02/2010 Proposed Implementation Date: 30/06/2010 Urgency: Non Urgent

More information

on the conditions for the application of FDA UIOLI pursuant to paragraph a) - d) of the CMP Guidelines

on the conditions for the application of FDA UIOLI pursuant to paragraph a) - d) of the CMP Guidelines Case Id: c8d4ee05-ccfc-464f-a253-4c5fad681ae0 Date: 13/09/2016 11:53:22 ACER Call for Evidence on the conditions for the application of FDA UIOLI pursuant to paragraph 2.2.3.1 a) - d) of the CMP Guidelines

More information

FERC GAS TARIFF. Second Revised Volume No. 1 CROSSROADS PIPELINE COMPANY FILED WITH THE FEDERAL ENERGY REGULATORY COMMISSION

FERC GAS TARIFF. Second Revised Volume No. 1 CROSSROADS PIPELINE COMPANY FILED WITH THE FEDERAL ENERGY REGULATORY COMMISSION FERC GAS TARIFF Second Revised Volume No. 1 Of CROSSROADS PIPELINE COMPANY FILED WITH THE FEDERAL ENERGY REGULATORY COMMISSION Communications concerning this Tariff should be addressed to: James R. Downs,

More information

Shippers meeting. Maintenance schedule. 2011, February 11 th

Shippers meeting. Maintenance schedule. 2011, February 11 th Shippers meeting Maintenance schedule 2011, February 11 th 1 2 Welcome Agenda Le t s have a look back on 2010 Sophie Ménard Marketing & Sales 2011 maintenance schedule Marie Benoit Gas System Direction

More information