Model Tubing O.D. (mm) Tubing I.D. (mm) 5 32 " 5 16 " Specifications

Size: px
Start display at page:

Download "Model Tubing O.D. (mm) Tubing I.D. (mm) 5 32 " 5 16 " Specifications"

Transcription

1 Nylon Tubing Series T/TIA For general pneumatic tubing, Nylon tubing Max. Operating Pressure Max. operating pressure (MPa) T0 T00 Series TIA T3 T003 Other metric size Operating temperature ( C) How to measure the minimum bending radius. Fixed end At a temperature of 0 C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure ter's rate of change is %. Precautions. Applicable for general industrial water. Please consult with SMC if using other kinds of fluid. Surge pressure must be under the max. operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to fittings and tubes..please exercise caution when using this item in a clean room. There is a possibility of plasticizer and other materials precipitating on the tube surface and detracting from the cleanliness level of the room. Tubing O.D. (mm) Tubing I.D. (mm) White (W) Red (R) Blue (BU) Yellow (Y) Green (G) 0 C or less Max. operating 0 C pressure Note ) 0 C (MPa) 0 C 0 C Applicable fittings Note ) Note ) Min. bending radius (mm) Note 3) Min. bending radius Bending value (Reference) Operating temperature Note ) Metric size (Series T) Inch size (Series TIA) T0 T003 T00 T0 T00 T7 T09 T3 TIA0 TIA0 TIA07 TIA TIA " " m roll 0 m roll (T3 is reel.) Tubing size Air/Water to +0 C, Water: 0 to +70 C (No freezing) Nylon One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings Nominal size (inch) " 3 " " 3 " " Nominal size (mm) 3. Note ) Be sure to operate under the maximum operating pressure conditions using the lower maximum operating specification of either the tubing or fittings. Note ) Mount an inner sleeve when using metal One-touch fittings in high-temperature environments of 0 C or more. Use self-align fittings at a temperature of 0 C or less. Note 3) The minimum bending radius is the representative value measured as shown in the left figure. Therefore, refer to the refraction value and make sure that the tubing is not bent or flattened. by the method in the left figure if the tubing is bent or flattened, etc. T0 B Tubing model Color Symbol Color B Black (Translucent) W White ( color) R (Translucent) BU Blue (Translucent) Y Yellow (Translucent) G Green (Translucent) 0 0 Length per roll Symbol Length 0 0 m roll 0 0 m roll 3 0

2 For general pneumatic tubing Pliable soft nylon tubing Max. Operating Pressure Max. operating pressure MPa. TS0.0. TS00... Other than.0 TS0, TS Operating temperature C Precautions. Compatible with water due to a change in materials. Compatible fluid types are printed on the tube body for differentiation, so please be sure to check this. Note) If using the previous TS/TISA series with water, the tube may shrink and cause air leakage or the tube may fall out.. The products which changed the material are applicable for general industrial water. Please contact SMC if using other kinds of fluid. Surge pressure must be under the max. operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to fittings and tubes. 3. Please exercise caution when using this item in a clean room. There is a possibility of plasticizer and other materials precipitating on the tube surface and detracting from the cleanliness level of the room. How to measure the minimum bending radius R At a temperature of 0 C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure R at the point where the outside diameter's rate of change is %. Fixed end Made to Order Soft Nylon Tubing Series TS/TISA 0 m roll 0 m roll (TS is reel.) Tubing size Metric size (Series TS) Inch size (Series TISA) TS0 TS00 TS00 TS7 TS09 TS TISA0 TISA0 TISA07 TISA TISA3 Tubing O.D. (mm) Tubing I.D. (mm) White (W) Red (R) Blue (BU) Yellow (Y) Green (G) Printing/ Previous NEW TS00 W Tubing model 3 " " Air/Water Note ) Max. 0 C or less operating 0 C pressure 0 C MPa 0 C Note ) 0 C Applicable fittings Note ) 3) Min. bending Min. bending radius radius mm Note ) Bending value (Reference) Operating temperature Note ) Print code SMC TS 00 SOFTNYLON x SMC TS 00 SOFTNYLON x 0 Length per roll Symbol Length 0 0 m roll 0 0 m roll (Black and white only) Nominal size (inch) " 3 " " 3 " " Air Air/Water Color Symbol Color B Black (Translucent) W White ( color) R Red (Translucent) BU Blue (Translucent) Y Yellow (Translucent) G Green (Translucent) (Please contact SMC for specifications in detail, dimensions, delivery and specifications other than those mentioned above.) 0 m reel Metric size and Inch size except ø: Suffix -X3 to the end of part number. Ex.) TS0R-0-X3 Longer length reel Metric size: Suffix -X3 to the end of part number. Ex.) TS0G-00-X3 0 m roll Inch size: Suffix -X to the end of part number. Ex.) TISA0BU-0-X Made to Order Availability Part no. Length TS0 TS00 TS00 TS7 TS09 TISA0 TISA0 TISA07 TISA TISA3 Color X3 0 m reel Black, White, 0 m reel Red, Blue, 00 m reel Yellow, Green 00 m reel X 0 m roll Red, Blue, Yellow, Green Nominal size (mm) One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings to +0 C, Water: 0 to +0 C (No freezing) Nylon Note ) Refer to the Printing/. Note ) Be sure to operate under the maximum operating pressure and operating temperature conditions using the lower specifications of either the tubing or fittings. Note 3) Mount an inner sleeve when using metal One-touch fittings in high-temperature environments of 0 C or more. Use self-align fittings at a temperature of 0 C or less. Note ) The minimum bending radius is the representative value measured as shown in the left figure. sure that the tubing is not bent or flattened. the method in the left figure if the tubing is bent or flattened, etc. 0

3 Soft Polyurethane Tubing Series TUS Suitable for piping in confined spaces Extremely flexible Soft Polyurethane Tubing TUS related accessories lnner Sleeve Series TJ Reinforces soft polyurethane tubing. Insert an inner sleeve into soft polyurethane tubing when used with a One-touch fitting. Series Table Tube O.D. (mm) Tube I.D. (mm) White (W) Red (R) Blue (BU) Yellow (Y) Green (G) Opaque (N) () Yellow brown (YB) TUS0. TUS00 TUS00 : 0m roll TUS. : 0m roll TUS0 Part No. TJ-0 TJ-00 TJ-00 TJ- TJ-0 Wall thickness Applicable tube model TUS0 TUS00 TUS00 TUS TUS0 Length C700T (Nickel plated) 0.mm Precautions quse nylon or polyurethane tubing for general industry water to prevent the tubing from coming out or bursting due to possibility of surge pressure generation. wthe value of the max. operating pressure is at a temperature of 0 C. Refer to the burst pressure characteristics curve for other temperatures. Avoid abnormal temperature rise which may burst the tubing. ethe value of the min. bending radius is at a temperature of 0 C. Higher temperatures allows the tubing to bend more. ruse inner sleeve taking the removing force into consideration when used with Onetouch fittings. Max. operating pressure Burst pressure Applicable tube fitting Min. bending radius (mm) Operating temperature () Tube drawing Without strenght N inner sleeve (Using One-touch fitting) With inner sleeve Air 0.MPa at 0 C Refer to burst pressure characteristics curve. One-touch fitting, Insert tube fitting, Hose nipple (3) 9 0 to +0 C (No freezing) Polyurethane Note) Not clear but opaque due to material. Note) Min. bending radius is measured as shown in the figure below. Note3) Always use inner sleeve (Series TJ) in safety circuit or critical area. TUS B Indication of tube model Bend the tube into U-form at a temperature of 0 C. Fix one end and close loop gradually. Measure R when the tube breaks or is crushed. 0 Burst Pressure Characteristics Curve Length per roll Symbol Roll size Colour indication 0 0m roll Symbol Colour 0 0m roll (Black, Blue only) B Black W White R Red BU Blue Y Yellow G Green N Opaque YB Yellow brown

4 Hard Polyurethane Tubing Series TUH TUS Soft Polyurethane TU Polyurethane Hard Polyurethane TUH (Standard Type) Soft Hard Maximum effective area increased nearly % TUH/Standard Type (Compared to polyurethane tubing TU00: O.D. mm, length m) O.D. (ød) I.D. (ød) Tubing inside diameter comparison Tubing O.D. (ød) TUH/Standard type Tubing TUH/High pressure type I.D. (ød) TU (mm). Operating pressure.0mpa (at 0 C) TUH/High Pressure Type Has the same operating pressure as series TS soft nylon tubing, and a bending radius equivalent to series TU polyurethane tubing. Can be restored even after folding Restoration is outstanding compared to nylon tubing, leaving no creases from folding.

5 Hard Polyurethane Tubing/Standard Type Series TUH Series 0m bundle 0m bundle TUH0 TUH0 TUH0 TUH73 TUH O.D. mm I.D. mm White (W) Blue (BU) Translucent (N) Max. operating pressure (at 0 C) Air Note ) 0.MPa Note ) Min. bending radius mm 30 3 Burst pressure Refer to the burst pressure characteristics curve. R Operating temperature 0 to 0 C Fixed side At a temperature of 0 C bend the tubing into a U shape. Then with one side fixed, gradually close the other side and measure R at the point where the tubing folds or flattens, etc. Polyurethane Note ) Consult SMC regarding other fluids. Water cannot be used due to the occurrence of hydrolysis. Note ) The maximum operating pressure is the value at 0 C. Refer to the burst pressure characteristic curve for other temperatures. Furthermore, an abnormal temperature increase due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius is measured at 0 C using the method shown in the figure at the left. At higher temperatures, breakage or flattening, etc., may occur at more than the minimum bending radius. Burst Pressure Characteristic Curve and Operating Pressure TUH0 B 0 Burst pressure MPa 3 Maximum operating pressure Operating temperature C Tubing model Color Symbol B W BU N Symbol 0 0 Color Black White Blue Translucent Bundle length Length 0m bundle 0m bundle

6 Hard Polyurethane Tubing/High Pressure Type Series TUH Series 0m bundle 0m bundle TUH0 TUH00 TUH00 TUH TUH0 O.D. mm I.D. mm.. White (W) Blue (BU) Translucent (N) Max. operating pressure (at 0 C) Air Note ).0MPa Note ) Min. bending radius mm Fixed side R At a temperature of 0 C bend the tubing into a U shape. Then with one side fixed, gradually close the other side and measure R at the point where the tubing folds or flattens, etc. Burst pressure Operating temperature Refer to the burst pressure characteristics curve. 0 to 0 C Polyurethane Note ) Consult SMC regarding other fluids. Water cannot be used due to the occurrence of hydrolysis. Note ) The maximum operating pressure is the value at 0 C. Refer to the burst pressure characteristic curve for other temperatures. Furthermore, an abnormal temperature increase due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius is measured at 0 C using the method shown in the figure at the left. At higher temperatures, breakage or flattening, etc., may occur at more than the minimum bending radius. Burst Pressure Characteristic Curve and Operating Pressure 7 TUH00 B 0 Burst pressure MPa 3 Maximum operating pressure Tubing Color Symbol B W BU N Bundle length Symbol Length 0 0m bundle 0 0m bundle Color Black White Blue Translucent Operating temperature C

7 Series TUH/ Specific Product Precautions Be sure to read before handling. Precautions on Usage. Water cannot be used due to the occurance of hydrolysis. Use nylon or polyurethane tubing for general industrial water. Furthermore, consult SMC regarding use with any fluids other than air.. The maximum operating pressure is the value at 0 C. Refer to the burst pressure characteristic curve for other temperatures. Furthermore, an abnormal temperature increase due to adiabatic compression can cause tubing to burst. 3. The minimum bending radius indicates the value at which the tubing will fold at a temperature of 0 C. At higher temperatures, the tubing may fold at more than the minimum bending radius.. Store away from direct sunlight in a location at no more than 0 C. 7

8 FEP Tubing (Fluoropolymer) Heat resistance:00 C It changes according to the operating pressure. Refer to the graph of the max. operating pressures on page. Colour variations Translucent Black Red Blue Size variations Metric size: ø to ø Applicable fittings One-touch fittings (Series KQ,KJ) Miniature fittings (Series M,MS) (Hose nipple type) Insert fittings (Series KF) High Purity Fluoropolymer fittings (Series LQ) Series TH Applications General pneumatic piping Food Semiconductor Medical care Automobile Certified to current Food Sanitation Legislation Ministry of Japanese Health and Safety, directive #370,99

9 FEP Tubing (Fluoropolymer) Series TH Series Tubing O.D. (mm) Tubing I.D. (mm) -0m roll -0m roll Metric size TH00 TH0 TH00 TH00 TH7 TH0 TH09 TH Colour Symbol Translucent N Red (Translucent) R Blue (Translucent) BU Black (Opaque) B How to measure the minimum bending radius. Fixed end R At a temperature of 0 C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure R at the point where the outside diameter's rate of change is %. Max. Operating Pressure Max. Operating Pressure MPa 3 0. TH00 TH0 TH00 TH0/TH TH00/TH7/TH Operating Temperature C Note) The maximum operating pressure varies dependant on the I.D. bore size even if the O.D. is the same. Applicable fittings Note ) Note ) Metric size Inch nominal size /3" Inch nominal size /" One-touch fittings: Series KQ, KJ Insert fittings: Series KF Fluoropolymer fittings: Series LQ Miniature fittings: Series M, MS (Hose nipple type) Max. operating pressure Refer to below Max. Operating Pressure. Min. bending Note 3) radius (mm) Note ) Operating temperature Air, Inert gas: -0 to 00 C Water: 0 to 0 C (No freezing) FEP (Fluorinated Ethylene Propylene Resin) Note ) When using a fluid in liquid form, the surge pressure must not exceed the maximum operating pressure. A surge pressure higher than the maximum operating pressure can cause breakage of the fittings, or rupture of the tubing. Furthermore, an abnormal temperature increase due to adiabatic compression can also result in ruptured tubing. Note ) Do not use in locations where the FEP tubing will move. Be sure to operate under the maximum operating pressure conditions using the lower maximum operating specification of either the tubing or fittings. After long term use or under high temperatures, some fittings leakage may occur due to material deterioration with age. Perform periodic inspections, and if any leakage is detected, replace with a new product immediately. (Refer to maintenance part of "Tubing Precautions " on the page 7-.) Refer to Best Pneumatics in "Fittings and Tubing" for all other precautions. For High Purity Fluoropolymer, refer to the precautions of CAT.ES70-7, "High Purity Fluoropolymer Fittings & Tubing." Note 3) Minimum bending radius is measured as shown left as representative values. Allow extra length when piping since the tubing may crush if bent more than the min. bending radius. Note ) Consult SMC if using any other fluids. TH00 N 0 Indication of tubing model Colour indication Symbol Colour N Translucent R Red (Translucent) BU Blue (Translucent) B Black (Opaque) Air, Water Note ), Inert gas Length per roll Symbol Roll size 0 0m roll 0 0m roll ) ) The 0m roll is only in the colour natural as standard available 9

10 Chemical Resistance of the Fluoropolymer FEP Chemicals in this table are inactive against FEP material Note ), however physical properties may be effected by temperature or pressure change. Please make sure that operating conditions do not cause problems since the use of FEP tubing under chemical environment is unsecured. -nitro--methyl propanol -nitrobutanol Pentabasic benzamide N-butylamine N-octadecanol N-butyl acetate O-cresol Di-isobutyl adipate Acetophenone Acetone Alniline Abietic acid Sulphuric chloride Isooctane Liquid ammonia Ethyl alcohol Ethyl ether Ethylene glycol Ethylenediamine Zinc chloride Aluminum chloride Ammonium chloride Calcium chloride Sulphuric chloride Iron chloride (III) Benzoyl chloride Magnesium chloride Hydrochloric acid Chlorine (absolute) Aqua regia Ozone Hydrogen peroxide Natrium peroxide Gasoline Permanganate Formic acid Xylene Chromic acid Chlorosulfonic acid Chloroform Paraffinum liquidum Allyl acetate Ethyl acetate Potassium Butyl acetate Sodium hypochlorite Carbon tetrachloride Dioxane Cyclohexanone Cyclohexane Dimethyl ether Dimethylsulfoxide Dimethylformamide Bromine Deionized water Nitric acid Mercury Ammonium hydroxide Potassium hydroxide Sodium hydroxide Cetane Soap, detergent Dibutyl sebacate Diethyl carbonate Tetrachloroethylene Tetrahydrofuran Tetrabromoethane Triethanolamine Trichloroethylene Trichloroacetic acid Toluene Naphtha Naphthalene Naphthol Lead Carbon dioxide Nitrogen dioxide Nitrobenzene Nitromethane Perchloroethylene Perphloroxylene Unsymmetrical dimethylhydrazine Hydrazine Pinene Piperidine Glacial acetic acid (Acetic acid) Pyridine Phenol Phthalic acid Dybutyl phthalate Dimethyl phthalate Hydrofluoric acid Naphthalene fluoride Nitrobenzene fluoride Furan Hexachlorethane Hexane Ethyl hexanoate Phenylcarbinol Benzaldehyde Benzonitrile Borax Boric acid Formic aldehyde (Formalin) Acrylic anhydride Acetic anhydride Methacrylic acid Allyl methacrylate Vinyl methacrylate Methyl alcohol Methyl ethyl ketone Methylene chloride Sulphuric acid Phosphoric acid Iron phosphate (III) Tri-n-butyl phosphate Tricresyl phosphate Note ) Inactive in chemistry terminology means - not to cause any chemical reaction. Reference cited: Teflon, the fluoropolymer handbook, Manual for the chemical applications of Teflon. Du Pond-Mitsui Fluorochemicals Co., Ltd. Teflon is a registered trademark for the fluoropolymer produced by E.I du Pond de Nemours & Company (Inc.) and Du Pond-Mitsui Fluorochemicals Co., Ltd.

11 Series TH Tubing Precautions Be sure to read before handling. Selection Warning. Confirm the specifications. The products appearing in this catalogue are designed for use only in compressed air systems (including vacuum). Do not use outside the specified ranges of pressure, temperature, etc., as this may cause damage or malfunction. (Refer to specifications.) SMC cannot assure the product quality when fluids other than air, water and inert gas are used. Consult with SMC for details.. In case of using the product for medical care This product is designed for use with compressed air system applications for medical care purposes. Do not use in contact with human bodily fluids, body tissues or transfer applications to a human living body.. Do not use in locations where the connecting threads and tubing connection will slide or rotate. The connecting theads and tubing connection will come apart under these conditions. Use rotary type one-touch fittings (Series KS, KX) in cases where sliding or rotation will occur. Only air can be used as the operating fluid, when using rotary type one-touch fittings.. Use tubing at or above the minimum bending radius. Using below the minimum bending radius can cause breakage or flattening of the tubing. 3. Never use the tubing for anything flammable, explosive or toxic such as, gas, fuel gas, or cooling mediums, since the contents can penetrate outward. Mounting. Before mounting confirm the model and size, etc. Also, confirm that there are no blemishes, nicks or cracks in the product.. When tubing is connected, consider factors such as changes in the tubing length due to pressure, and allow sufficient leeway. 3. Mount so that fittings and tubing are not subjected to twisting, pulling or moment loads. This can cause damage to fittings and flattening, bursting or disconnection of tubing, etc.. Mount so that tubing is not damaged due to tangling and abrasion. This can cause flattening, bursting or disconnection of tubing, etc. Piping. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe. Do not allow chips of the piping thread or the seal material to go in. Air Supply Warning. Types of fluid This product is designed for use with compressed air. Consult SMC if a different fluid is to be used. Consult SMC regarding products for use with general purpose fluids, to confirm which fluids can be used.. When there is a large amount of drainage. Compressed air containing a large amount of drainage can cause the malfunction of pneumatic equipment. An air dryer or Drain Catch should be installed upstream from filters. 3. Drain management If air filter drains are not flushed regularly, the drainage will flow downstream leading to the malfunction of pneumatic equipment. In cases where the management of drain flushing will be difficult, the use of filters with automatic drains is recommended. For details on the quality of compressed air mentioned above, refer to SMC's "Best Pneumatics" catalogue vol.. Operating Environment Warning. Do not operate in locations in an explosive atmosphere.. Do not operate in locations where vibration or impact occurs. 3. In locations near heat resources, block off radiant heat. Maintenance. Check for the following during regular maintenance, and replace components as necessary. a) Scratches, gouges, abrasion, corrosion b) Leakage c) Twisting, flattening or distortion of tubing d) Hardening, deterioration or softness of tubing. Do not repair or patch the replaced tubing or fittings for reuse. 3. When using insert or miniature fittings over a long period, some leakage may occur due to age deterioration of the materials. Perform periodic inspections, and if any leakage is detected, correct the problem by additional tightening. If tightening becomes ineffective, replace the fittings with a new product immediately.

12 Polyurethane Coil Tubing Series TCU For flexible tubing Compact piping possible Burst Pressure Characteristics Curve Number of tubes Tube O.D. (mm) Tube I.D. (mm) Max. operating pressure () Burst prssure Operating temperature Colour TCU 0B- TCU 0B- TCU 0B-3 TCU 00B Air () TCU 00B- 0.MPa at 0 C Refer to pressure characteristics curve. 0 to +0 C Polyurethane Black Note ) Consult SMC if using for other fluids than air. Note ) Refer to burst pressure characteristics curve for other temperatures. Avoid abnormal temperature rises. Dimensions TCU 00B-3 TCU 00B- Spec. Part No. TCU0B- TCU0B- TCU0B-3 TCU00B- TCU00B- TCU00B-3 TCU00B- Made to Order Change of coil turns, Color change Tube size (mm) O.D. I.D.. Dimensions are changeable due to material. Dimension of coil (mm) No. of tubes No. coil windings per tube length L ød (Consult SMC for detailed specifications, dimensions and delivery.) Max. operating length (m).. Standard unit of packing tubes/ case Spec. Tube size (mm) Coil (mm) No. coil No. of windings Max. operating Part No. O.D. I.D. L ød tubes per tube length length (mm) TCU0 -- N -X N X 3 to 90 L X TCU0 -- N -X. N X 3 to 90 L X TCU0-3- N -X N X 3 3 to 3 L X TCU00 -- N -X N X 3 to 90 L X TCU00 -- N -X N X 37 3 to L X TCU00-3- N -X N X to L X B (Black), W (White), R (Red), BU (Blue), Y (Yellow), G (Green), C (Clear), YR (Orange) N Coil turns Spec. Part No. TCU00 -- N -X TCU00 -- N -X TCU -- N -X TCU -- N -X TCU0 -- N -X TCU0 -- N -X Tube size (mm) Coil (mm) O.D. I.D. L ød N X 3 N X. N X N X 0 N X 7 N X 7 No. of tubes No. coil windings per tube length 3 to 90 L X to 0 3 to 3 to 3 3 to 3 3 to 30 Max. operating length (mm) L X L X + 00 L X L X + 00 L X

13 Polyurethane Flat Tubing Series TFU Compact piping possible Burst Pressure Characteristics Curve Part No. Number of tubes Tube O.D. (mm) Tube I.D. (mm) Max. operating pressure () Burst prssure Operating temprature Colour Min. bending radius (mm) Tube length per roll (m) TFU 0B- TFU 0B-3 3 TFU 00B- TFU 00B-3 3 Air () TFU 00B-. 0.MPa at 0 C Refer to burst pressure characteristics curve 0 to +0 C (No freezing) Polyurethane Black 0 Note) Consult SMC if using for other fluids than air. Note) Refer to burst pressure characteristics curve for other temperatures. Avoid abnormal temperature rises. TFU 00B-3 3 TFU0 B Indication of tube model Colour indication Symbol Colour B Black Number of tubes Symbol Number 3 3 Made to Order q Colour change (m roll) Suffix X to the end of part number. Ex.) TFU00BU--- X W: White, R: Red, BU: Blue, Y: Yellow, G: Green, C: Clear, YR: Orange (All tubes are same colour.) w Longer roll length (0m or 0m roll) Suffix X3 to the end of part number. Ex.) TFU0B--0- X3 e Number of tubes (m roll) Suffix X to the end of part number. Ex.) TFU00B--- X TFU0 TFU00 TFU00 TFU TFU0 Tube O.D. (mm) Tube I.D. (mm).. Number of tubes 3 7 (Consult SMC for detailed specifications, dimensions and delivery.) : m roll : 0m roll : 0m roll 3

14 Flame Resistance (Equivalent to UL-9 Standard V-0) FR Soft Nylon Tubing Series TRS Applicable for general air pressure and water in a spark atomosphere such as spot welding. Flame resistance tube Series Table Tube O.D. (mm) Tube I.D. (mm) White (W) TRS003 3 TRS00 : 0m roll : 0m roll TRS TRS0. Burst Pressure Characteristics Curve Red (R) Blue (BU) Green (G) Max. operating pressure Burst pressure Min. bending radius (mm) 7 Air, Water.MPa at 0 C Refer to burst pressure characteristics curve Operating temperature 0 to +0 C (Water: 0 to 0 C)(No freezing) Flame resistance nylon (UL-9 Standard V-0) Precautions qapplicable for general industry water. Consult SMC if using for other kinds of fluid. Surge pressure must be under the max. operating pressure. If exceeding that value, fitting may be damaged and tubing may be burst. wthe value of the max. operating pressure is at a temperature of 0 C. Refer to the burst pressure characteristics curve for other temperatures. Avoid abnormal temperature rises which may burst the tubing. ethe value of the min. bending radius is at a temperature of 0 C and O.D. variable rate % max. In case that operating temperature is higher than 0 C, O.D. variable rate may be over % even if bending radius is within the specified range. TRS B Indication of tube model 0 Colour indication Symbol Colour B Black W White R Red BU Blue G Green Length per roll Symbol Roll size 0 0m roll 0 0m roll

15 Flame Resistance (Equivalent to UL-9 Standard V-0) FR Double Layer Tubing Series TRB Suitable for air and water piping in environments where sparks from spot welders, etc., may be a problem. Double layer design using flame resistant resin (equivalent to UL-9 Standard V-0) for outer layer. Series Table Inner tube O.D. (mm) Inner tube I.D. (mm) Outer layer thickness (mm) () Outer layer colour White (W) Red (R) Blue (BU) Yellow (Y) Green (G) : 0m roll : 0m roll TRB00 TRB00 TRB7 TRB Minimum bending () radius (mm) 3 Burst Pressure Characteristics Curve Air, Water () Max. operating pressure (3) Burst pressure Ambient and fluid temperature Inner tube Outer layer.0mpa at 0 C Refer to burst pressure characteristics curve. 0 to +0 C (Water: 0 to 0 C) (No freezing) Nylon PVC (Equivalent to UL-9 Standard V-0) Note) The colour of all inner tube is black. Note) Applicable for general industry water. Consult SMC if using for other kinds of fluid. Surge pressure must be under the max. operating pressure. Note3) Refer to burst pressure characteristics curve for other temperatures. Avoid abnormal temperature rises. Note) The value for a temperature of 0 C and O.D.variable rate % max. TRB7 B 0 Indication of tube model Colour indication Symbol Colour Symbol Colour B W R Black White Red BU Y G Blue Yellow Green Length per roll Symbol 0 0 Roll size 0m roll 0m roll

16 FR Double Layer Tubing Series TRB How to Install to One-touch Fitting Length of tube to be inserted into One-touch fitting is indicated on the outer layer of TRB tubing. Cut the tube according to this indication. (Procedureq) and then strip off the outer layer. (Procedurew) for installing tube. Precautions qapplicable for general industrial water. Consult SMC if using for other kinds of fluid. Surge pressure must be under the max. operating pressure. If exceeding that value, fitting may be damaged and tubing may be burst. wthe value of the max. operating pressure is at a temperature of 0 C. Refer to the burst pressure characteristics curve for other temperatures. Avoid abnormal temperature rises which may burst the tubing. ethe value of the min. bending radius is at a temperature of 0 C and O.D. variable rate % max. In case that operating temperature is higher than 0 C, O.D. variable rate may be over % even if bending radius is within the specified range.

17 Flame Resistant (Equivalent to UL-9 Standard V-0) FR Double Layer Polyurethane tubing SeriesTRBU Series Table - 0m bundle - 0m reel TRBU00 Internal tube O.D. mm Internal tube I.D. mm External layer thickness mm TRBU00 TRBU TRBU0. Internal tube External layer Note ) External layer colour White (W) Red (R) Blue (BU) Yellow (Y) Green (G) Sectional view of FR double layer tube Note ) Minimum bend radius mm Note ) Air, Water Note 3) Maximum operating pressure (at 0 C) Burst pressure Ambient and fluid temperature 0.MPa {.kgf/cm } Refer to burst pressure characteristics curve 0 to 0 C For water 0 to 0 C (without freezing) Burst Pressure Characteristics Curve and Operating Pressure.0 s Internal tube External layer Polyurethane PVC (equivalent to UL-9 standard V-0) Note ) The colour of all internal tubes is black. Note ) Can be used with general industrial water. Contact SMC if used with other fluids. Also keep surge pressure at or below the maximum operating pressure. Note 3) In case of other temperatures, refer to the burst pressure characteristics curve. In addition, operate so that abnormal temperature rise due to adiabatic compression does not occur. Note ) Indicates the bending value of the tubing at a temperature of 0 C. TRBU B 0 Burst pressure MPa Burst pressure Maximum operating pressure Operating temperature C Tube model Colour Symbol B W R Colour Black White Red Roll length Symbol 0 0 Symbol BU Y G Length 0m bundle 0m reel Colour Blue Yellow Green 7

18 FR Double Layer Polyurethane Tubing Series TRBU Installation on One-touch Fittings Since the pitch length for installation on a One-touch fitting is indicated on the external layer of TRBU tubing, cut the tubing according to this indication (Step ), strip off the external layer only (Step ), and then install on the One-touch fitting. x SMC FR TUBE TRBU00 x Pitch indication: All installation lengths with same pitch Step x SMC FR TUBE TRBU00 x Step Cut internal and external layers x SMC FR TUBE Strip off external layer only Precautions on Useage. Useage is possible with general industrial water. Contact SMC if product will be used with other fluids. Also, keep surge pressure at or below the maximum operating pressure. If surge pressure exceeds the maximum operating pressure, this can cause damage to fittings or bursting of the tubing.. The maximum operating pressure is the value when at 0 C. In case of other temperatures, refer to the burst pressure characteristics curve. Furthermore, bursting of the tubing can be caused by an abnormal temperature rise due to adiabatic compression. 3. The minimum bend radius indicates the bending value of the tubing at a temperature of 0 C. The tubing may bend beyond the minimum bend radius at higher temperatures.. Tubing should be stored in a location out of direct sunlight and at 0 C or below.

19 Antistatic Tubing Series TA Conductive tubing prevents troubles caused by static electricity. Antistatic soft nylon tubing/series TAS For air pressure piping to product or assembly while preventing static electricity. Flame resistant tube (UL-standard, V-0) Burst Pressure Characteristics Curve Series Table Tube O.D. (mm) Tube l.d. (mm) TAS3 3.. TAS0. TAS00 : 0m roll : 0m roll TAS00 TAS. TAS0 () Max. operating pressure.mpa at 0 C Burst pressure Refer to burst pressure characteristics curve. Min. bending radius (mm) () Operating temperature 0 to 0 C Surface resistance Conductive nylon + Flame resistant nylon (UL-9standard, V-0) to 7 Ω Note) Refer to burst pressure characteristics curve for other temperatures. Avoid abnormal temperature rises. Note) The value at temperature of 0 C and O.D. variable rate % max. TAS B 0 Indication of tube model Colour indication Symbol Colour B Black Length per roll Symbol Roll size 0 0m roll 0 0m roll For air pressure piping to product or assembly while preventing static electricity. Flexible tube Antistatic polyurethane tubing/se ries TAU Series Table Tube O.D. (mm) Tube l.d. (mm) TAU30 3. TAU0. TAU00 : 0m roll : 0m roll TAU00 TAU. TAU0 Burst Pressure Characteristics Curve () Max. operating pressure Burst pressure 0.9MPa at 0 C Refer to burst pressure characteristics curve. Min. bending radius (mm) () Operating temperature 0 to 0 C Conductive polyurethane Surface resistance to 7 Ω Note) Refer to burst pressure characteristics curve for other temperatures. Avoid abnormal temperature rises. Note) The value at temperature of 0 C. TAU B 0 Indication of tube model Colour indication Symbol Colour B Black Length per roll Symbol Roll size 0 0m roll 0 0m roll 9

Fabrics for Flexible Connections

Fabrics for Flexible Connections Value Based On Quality Fabrics for Flexible Connections toll-free 800.621.1207 fax 773.775.5065 www.ventfabrics.com Ventglas Recommended for Conventional HVAC Systems Ventglas, a heavy glass fabric, double-coated

More information

Fluoropolymer Tubing Variations

Fluoropolymer Tubing Variations Fluoropolymer Tubing Variations TL/TIL/TLM/TILM/TH/TIH/TD/TID Series High Purity Fluoropolymer Tubing TL/TIL Series Super PFA It is suitable for applications which require a highly smooth internal surface

More information

RYTON (PPS) Chemical Compatibility & Chemical Resistance Chart

RYTON (PPS) Chemical Compatibility & Chemical Resistance Chart RYTON (PPS) Chemical Compatibility & Chemical Resistance Chart Explanation of Footnotes 1. Satisfactory to 72 F (22 C) 2. Satisfactory to 120 F (48 C) Ratings -- Chemical Effect A = Excellent. B = Good

More information

Fluoropolymer Tubing Variations

Fluoropolymer Tubing Variations Fluoropolymer Tubing Variations TL/TIL/TLM/TILM/TH/TIH/TD/TID Series High Purity Fluoropolymer Tubing TL/TIL Series Super PF It is suitable for applications which require a highly smooth internal surface

More information

Chemical Resistance and Material Selection Guide for Drum Pumps

Chemical Resistance and Material Selection Guide for Drum Pumps esistance and Material Selection Guide for Drum Pumps The information in the following guide lists the corrosion resistance of four materials used in the drum pump outer tubes. Additional wetted materials

More information

Applications / Compatibility Guide

Applications / Compatibility Guide Applications / Compatibility Guide Hunsworth Lane, Cleckheaton, West Yorkshire. BD19 3UJ Telephone: +44 1274 878787 Fax: +44 1274 862588 e.mail: smith@novussealing.com Website: www.novussealing.com If

More information

Chemical Resistance and Material Selection Guide for FTI Drum Pumps

Chemical Resistance and Material Selection Guide for FTI Drum Pumps esistance and Material Selection Guide for FTI Drum Pumps The information in the following guide lists the corrosion resistance of four materials used in FTI drum pump outer tubes. Additional wetted materials

More information

Preferred. Steel, Epoxy Powder Coated. Satisfactory. Limited

Preferred. Steel, Epoxy Powder Coated. Satisfactory. Limited Corrosion Resistance We manufactures enclosures from a wide range of materials, offering varying degrees of resistance against chemical corrosion. All materials are affected by corrosion in some manner.

More information

technical tubes and hoses

technical tubes and hoses technical s and hoses technical s and hoses Legris policy is to be able to offer its customers a complete range of fittings, and in addition, a full range of s and hoses, compatible with the different

More information

Stainless Steel 316 Insert Fittings

Stainless Steel 316 Insert Fittings Stainless Steel 1 Insert Fittings Series KFG A reliable seal Holds the tube tightly Insert An insert mechanism can provide reliable retaining force on tubes made of a wide variety of materials Superior

More information

material chemical Note ) This data is subject to change for update of specifications and availability of newer formation.

material chemical Note ) This data is subject to change for update of specifications and availability of newer formation. Note: The following tables are intended to serve only as your reference of s, and are not intended to using s, please exercise your own judgment based on the verification with your real machine. For s

More information

Polystone G (HDPE) Polystone P (Polypropylene) Shaping the Future through Innovation.

Polystone G (HDPE) Polystone P (Polypropylene) Shaping the Future through Innovation. Polystone G (HDPE) Polystone P (Polypropylene) Shaping the Future through Innovation. Innovation. 11/2011 Competence. Quality. Semi-Finished Thermoplastics Röchling A World Leader in Engineering Plastics

More information

technical information

technical information CHEMICAL RESISTANCE TABLES Version: 19-08-10 ADD Resins and Chemicals (Pty) Ltd Distribute a comprehensive range of unsaturated polyester resins for chemical resistance applications. The resins recommended

More information

Guide to Safe Handling & Storage of Hazardous Materials

Guide to Safe Handling & Storage of Hazardous Materials Guide to Safe Handling & Storage of Hazardous Materials I. ACIDS VI. PYROPHORICS II. BASES (CAUSTICS) VII. PEROXIDE FORMING CHEMICALS III. FLAMMABLES VIII. TOXIC CHEMICALS IV. OXIDIZERS IX. CARCINOGENS

More information

Teflon. The FACTS. Teflon PFA Coatings. Nonstick & Industrial Coatings Green Brown Green MP-310 Clear MP-610 Black

Teflon. The FACTS. Teflon PFA Coatings. Nonstick & Industrial Coatings Green Brown Green MP-310 Clear MP-610 Black PFA Coatings Primers Low-Build Topcoat High-Build Topcoat 420-703 Black 420-704 Green 420-705 Brown 857-110 Clear 857-114 Green MP-310 Clear MP-610 Black 532-5450 Powder, Clear 532-13054 Powder, Ruby Red

More information

Chemical Resistance Table Polypropylene

Chemical Resistance Table Polypropylene Description: Polypropylene Chemical Resistance Table Polypropylene Introduction The table in this document summarises the data given in a number of polypropylene chemical resistance tables at present in

More information

Chemical Resistance Table KPC Polypropylene

Chemical Resistance Table KPC Polypropylene Scope and Field Application This document establishes a provisional classification of the chemical resistance of polypropylene with respect to about 180 fluids. It is intended to provide general guidelines

More information

4 SPRINGS 6 SPRINGS 8 SPRINGS 10 SPRINGS 12 SPRINGS 14 SPRINGS

4 SPRINGS 6 SPRINGS 8 SPRINGS 10 SPRINGS 12 SPRINGS 14 SPRINGS Sheet No.: 4.201 Rev. A INSTALLATION OF SPRINGS OF P-SERIES ACTUATOR P 4 SPRINGS 6 SPRINGS 8 SPRINGS SPRING 10 SPRINGS 12 SPRINGS 14 SPRINGS Sheet No.: 4.202 Rev. A INSTALLATION OF SPRINGS OF E-SERIES

More information

ATTACHMENT 3. Firestone Geomembrane Chemical Resistance Chart

ATTACHMENT 3. Firestone Geomembrane Chemical Resistance Chart ATTACHMENT 3 Firestone Geomembrane Chemical Resistance Chart Firestone Geomembrane exposure to these chemicals causes no swelling, softening or surface deterioration of the membrane. Acetamide Acryimide

More information

PRODUCT DATA SHEET (rev. 2.12/2017)

PRODUCT DATA SHEET (rev. 2.12/2017) PRODUCT DATA SHEET (rev. 2.12/2017) 1. Name PE-RT/EVOH/PE-RT floor-heating multilayer pipe 2. Product features and intended use The multilayer pipe PE-RT/EVOH/PE-RT is designed and manufactured by Capricorn

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION PRODUCT SPECIFICATION Resco s ChemLab is the ultimate laboratory benchtop for high chemical use. The Electro Beam Cured (EBC) surface, gives it an extra stain resistance and high hygiene, making it the

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS SeamTek Type 4 Epoxy Quartz Flooring System (1/8 ) Section 09700 800-638-9874 www.lspinc.com Part 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract,

More information

Temperature Sensing Standard Thermowells for Industrial Applications. Velocity Ratings of Wells. View Product

Temperature Sensing Standard Thermowells for Industrial Applications. Velocity Ratings of Wells. View Product Standard for Industrial Applications Well failures, in most cases, are not due to the effects of pressure and temperature. The calculations necessary to provide adequate strength under given conditions

More information

LIGHTBLOCKS BOARD. stress cracking. chemical

LIGHTBLOCKS BOARD. stress cracking. chemical e info@ chemical stress cracking LIGHTBLOCKS BOARD Contents This brochure provides a summary of the chemical behavior of our semifinished product groups by listing the chemical substances ed on these materials

More information

PRODUCT DATA SHEET (rev. 2.12/2017)

PRODUCT DATA SHEET (rev. 2.12/2017) PRODUCT DATA SHEET (rev. 2.12/2017) 1. Name PE-RT/EVOH/PE-RT installation multilayer pipe 2. Product features and intended use The multilayer pipe PE-RT/EVOH/PE-RT is designed and manufactured by Capricorn

More information

compared to other tubing. It is 5 to 10 times more wear resistant and lighter in weight than any rubber hose. ATP Surethane NSF 51

compared to other tubing. It is 5 to 10 times more wear resistant and lighter in weight than any rubber hose. ATP Surethane NSF 51 Surethane NSF 51 polyurethane (PUR) Shore 98 tubing is made from the highest quality raw materials available. It is etherbased to provide excellent hydrolysis, oil and cold resistance. Surethane NSF 51

More information

Profiles in thermoplastics rubber TPeRX

Profiles in thermoplastics rubber TPeRX Profiles in thermoplastics rubber TPeRX 30 22 Rubber Technology Edge protectors Available on Stock Sidesight 60 38 38 Elastomer joint with adhesive Colour: yellow Packaging: 10 x 2 meters Reference: F1123

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS 800-638-9874 www.lspinc.com Part 1 - GENERAL SeamTek Type 3 Healthcare Epoxy Quartz Flooring System (3/16 ) Section 09700 1.01 RELATED DOCUMENTS A. Drawings and general provisions

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS Part 1 - GENERAL TECHNICAL SPECIFICATIONS SeamTek Type 3 Epoxy Quartz Flooring System (3/16 ) Section 09700 800-638-9874 www lspinc com 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract,

More information

DELIVER TO END USER AFTER INSTALLATION IS COMPLETED

DELIVER TO END USER AFTER INSTALLATION IS COMPLETED PRODOME TM SKYLIGHT DELIVER TO END USER AFTER INSTALLATION IS COMPLETED RECOMMENDED TOOLS PARTS LIST 1. #12 x 1-1/2 Hex Washer Head Screw (Other sizes and types available) 2. (Appearance may vary depending

More information

CORROSION DATA GUIDE

CORROSION DATA GUIDE CORROSION DATA GUIDE This guide was developed from general corrosion literature, standard references and field experiences. Recommendations for corrosive service are given to assist the user in making

More information

Industrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax:

Industrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax: 08-13-2003 Page #1 of 13 Temperature ( o F) for Acetaldehyde --- 100 100 Acetic Acid #10 150 150 Acetic Acid 10-100 CM CM Acetic Anhydride --- 100 120 Acetone --- 120 120 Acetonitrile --- 120 120 Acetophonone

More information

Polypropylene Chemical Resistance Table Polypropylene

Polypropylene Chemical Resistance Table Polypropylene ART 006 11.07.2001 Ed. 4 Introduction The table in this document summarises the data given in a number of polypropylene chemical resistance tables at present in use in various countries, derived from both

More information

ADVANTAGES OF POLYETHYLENE PIPES COMPARED TO PVC PIPES

ADVANTAGES OF POLYETHYLENE PIPES COMPARED TO PVC PIPES 1 ADVANTAGES OF POLYETHYLENE PIPES COMPARED TO PVC PIPES The main advantages and improvements in drainage networks that will be obtained by the use of PE MAGNUM pipes, in comparison to PVC pipes are: 1.

More information

CHEMICALS ALCOHOLS BASES

CHEMICALS ALCOHOLS BASES ACIDS Acetic Acid Acetic Acid Glacial Acetic Acid, Acrylic Acid Aqua Regia Benzene Sulfonic Acid Benzoic Acid Boric Acid Carbolic Acid Carbonic Acid Chloroacetic Acid Chlorosulfonic Acid D D D Chromic

More information

indicates possibility of environmental stress cracking

indicates possibility of environmental stress cracking CHEMCAL RESSTANCE CHART This Resistance chart is to be used as a guide to assist you in determining the suitability of LLDPE Rotathene for storing the chemical indicated. Storage is a critical application

More information

DuPont FEP Film FLUOROCARBON FILM. Information Bulletin. Description. FEP Is Unique Among Plastics. DuPont FEP Film Is Offered

DuPont FEP Film FLUOROCARBON FILM. Information Bulletin. Description. FEP Is Unique Among Plastics. DuPont FEP Film Is Offered DuPont FEP Film FLUOROCARBON FILM Information Bulletin Description DuPont FEP fluorocarbon film offers the outstanding properties of FEP fluoropolymer in a convenient, easy-to-use form. It can be heat-sealed,

More information

Clean Speed Controller with One-touch Fitting

Clean Speed Controller with One-touch Fitting Clean Speed Controller with One-touch Fitting Series -FPQ/-FPG Series -FPG Series -FPQ P N Speed controllers for clean room use V S R Q -FPQ: (electroless nickel plated) and -FPG: are now available as

More information

Perfection in Liquid Handling HIGHEST RELIABILITY IN DISPENSING

Perfection in Liquid Handling HIGHEST RELIABILITY IN DISPENSING Perfection in Liquid Handling HIGHEST RELIABILITY IN DISPENSING 13 VITLAB Dispenser line: genius 2, simplex 2, and TA 2 VITLAB genius 2 and simplex 2 bottle-top dispensers are a family of instruments with

More information

AGC Chemicals, Fluoropolymers Group

AGC Chemicals, Fluoropolymers Group AGC Chemicals, Fluoropolymers Group Shin-Marunouchi Bldg.,1-5-1 Marunouchi Chiyoda-ku,Tokyo -845 Japan Phone: +81-3-3218-5875 Facsimile: +81-3-3218-7856 http://www.agc.com/ Fluon Website http://www.fluon.jp/

More information

CHEMCAST is the only high quality acrylic sheet that can provide you with short runs capability and color selection to fit your specific needs.

CHEMCAST is the only high quality acrylic sheet that can provide you with short runs capability and color selection to fit your specific needs. INTRODUCTION What makes CHEMCAST acrylic sheet notably different is: CHEMCAST is the only high quality acrylic sheet that can provide you with short runs capability and color selection to fit your specific

More information

Validation Guide. GBPES-series 0.2, 0.45, & 0.65 Micron Membrane Elements F517A_160901

Validation Guide. GBPES-series 0.2, 0.45, & 0.65 Micron Membrane Elements F517A_160901 Validation Guide GBPES-series 0.2, 0.45, & 0.65 Micron Membrane Elements F517A_160901 Table of Contents I. Technical Specifications... 3 1. Mechanism of Filtration... 3 2. Pore Size... 3 3. Materials of

More information

DMR Srl Telefono:

DMR Srl Telefono: Anti-Slip ANTI SLIP PRODUCT Product Specification SPECIFICATION Identification of the Product & the Company Product Name: Company Name: Anti-Slip Category - Glass Reinforced Plastic (GRP) safe access products

More information

3M Dyneon Fluoropolymers. Product Information. Dyneon solutions. for the Chemical Processing Industry

3M Dyneon Fluoropolymers. Product Information. Dyneon solutions. for the Chemical Processing Industry Fluoropolymers Product Information Dyneon solutions for the Chemical Processing Industry Fluoroplastics Chemical Resistance (Aging Duration of 1000 Hours) Chemicals Concen. % Temp. C PTFE & TFM Modified

More information

Super Erecta Wall Mount Technical Data T10.40 TIM CAMPBELL

Super Erecta Wall Mount Technical Data T10.40 TIM CAMPBELL Wilkes-Barre, PA 18705 www.metro.com Super Erecta Wall Mount Technical Data T10.40 Finish Temp. Abrasion Chip Res. Nickel Chrome Brite Metroseal II Stainless Designer Very Good Very Good Application

More information

Balston Liquid Filters

Balston Liquid Filters Balston Vacuum Pump Exhaust and Inlet Filters Balston Liquid Filters Filtration to 0.22 micron with exceptional filter life, even for the dirtiest liquids Excellent chemical and solvent resistance Compliance

More information

Liquid Filters. Filter Cartridge and Housing Selection. How To Select The Filter Cartridge. How To Select The Filter Housing

Liquid Filters. Filter Cartridge and Housing Selection. How To Select The Filter Cartridge. How To Select The Filter Housing Filter Cartridge and Housing Selection How To Select The Filter Cartridge 1 Specify the level of final filtration required, within the range of 75 micron to 0.22 micron. 2 Select the filter system using

More information

Stainless Steel 316 One-touch Fittings

Stainless Steel 316 One-touch Fittings Stainless Steel 6 One-touch Fittings Series KQG aterial etal parts: parts: Special FK Grease-free Fluid temperature 5 to 0 C Can be used with steam. pplicable material FEP, PF, Nylon, Soft nylon, Polyurethane

More information

Company Introduction.

Company Introduction. Company Introduction www.notedome.com Our Production Facility Utilising a modular approach to our production facility, we planned to maximise our flexibility by having a selection of reaction/blending

More information

Filament wound Plastic Self-lubricating Bearings

Filament wound Plastic Self-lubricating Bearings Filament wound Plastic Self-lubricating Bearings Filament wound Plastic Self-lubricating Bearings CSB-CRB: Glass fiber epoxy-impregnated with PTFE and high strength fibers CSB-CRG: Glass fiber epoxy-impregnated

More information

Properties of standard Bal Spring canted coil spring materials

Properties of standard Bal Spring canted coil spring materials Custom components that drive tomorrow s technologies. Properties standard Bal Spring canted coil spring materials Technical Report TR-9 (Rev. Q; 10-19-17) (100-44) 19650 Pauling Foothill Ranch, CA USA

More information

DESCRIPTION RECOMMENDATIONS CHEMICALLY RESISTANT TO: PTFE Tape

DESCRIPTION RECOMMENDATIONS CHEMICALLY RESISTANT TO: PTFE Tape PTFE Tape DESCRIPTION Black Swan PTFE Tape is a clean, self-lubricating tape, which is used to make threaded connections. It offers a positive pressure seal to 10,000 lbs. PSI from a temperature range

More information

PRODUCT DATA SHEET PDS A133_E. Metric thread M 1.5 pitch CEI EN CEI EN Pg thread DIN Dimensions DIN

PRODUCT DATA SHEET PDS A133_E. Metric thread M 1.5 pitch CEI EN CEI EN Pg thread DIN Dimensions DIN Metric thread M 1.5 pitch CEI EN 60423 CEI EN 50262 Ref. Hole min-max Spanner Spanner min-max Quantity Nickel Head Body Box/Bag Plated Brass 2003M1221N M12x1,5 12,5 4-6 13 14 5 13-16 500/100 2003M1621N

More information

Chemical resistance of Saniclad PVC products

Chemical resistance of Saniclad PVC products resistance of Saniclad PVC products The table that appears in the following pages lists the resistance of SAI CLAD PVC sheets to a number of commonly encountered chemicals and other corrosive media at

More information

Polystone M (UHMW-PE) Shaping the Future through Innovation.

Polystone M (UHMW-PE) Shaping the Future through Innovation. (UHMW-PE) Shaping the Future through Innovation. Innovation. 11/2015 Competence. Quality. Semi-Finished Thermoplastics Röchling A World Leader in Engineering Plastics Röchling World Leader in Engineering

More information

Chem-Stud CHEMICAL SPIN TYPE CAPSULE ADHESIVE PRODUCT DESCRIPTION CHEM-STUD ADHESIVE PROPERTIES

Chem-Stud CHEMICAL SPIN TYPE CAPSULE ADHESIVE PRODUCT DESCRIPTION CHEM-STUD ADHESIVE PROPERTIES 192 Chem-Stud SPIN TYPE CAPSULE ADHESIVE BASE MATERIAL Solid Concrete SIZE RANGE 3" to 1-1" Anchor Rod, No. 3 to No.10 Reinforcing Bar ANCHOR MATERIAL Ester Based Resin PRODUCT DESCRIPTION The Chem-Stud

More information

PPH Rod Extruded. Product information. Applications. This document contains. Product full identity: Properties.

PPH Rod Extruded. Product information. Applications. This document contains. Product full identity: Properties. Product information Product full identity: Polypropylene Homopolymer PPH is light weight (SG 0.91) has improved chemicalresistance, stiffness, improved higher working temperature compared to PPC (0 C to

More information

Diaphragm Liquid Pumps

Diaphragm Liquid Pumps Diaphragm Liquid Pumps MODELS 52 F F 12 FP 21 52 F F 12 FP 21 FEATURES Self priming Dry running Oil-less, non lubricated Suitable for continuous operation Chemical resistent pump materials for aggressive

More information

Gas Sampling Bags. Cost-Effective Alternatives for Air Sampling. Restek Air

Gas Sampling Bags. Cost-Effective Alternatives for Air Sampling. Restek Air Restek Air Gas Sampling Bags Cost-Effective Alternatives for Air Sampling Ideal for whole air sampling at ppb-ppm levels. Select from Tedlar, ALTEF, and multi-layer foil bags in a wide range of sizes.

More information

Diaphragm Liquid Pumps

Diaphragm Liquid Pumps Diaphragm Liquid Pumps Series 52 F F 12 FP 21 52 F F 12 FP 21 Product Features Self priming Dry running Oil-less, non lubricated Suitable for continuous operation (motor shaft should be horizontal) Chemical

More information

Chemical Resistance-VF 105

Chemical Resistance-VF 105 Chemical Resistance-VF 105 1= Suitable for constant immersion, constant flow, and/or areas with frequent spills and/or poor drainage. 2 = Suitable for at least 72 hours of containment and for intermittent

More information

Industry Standards & Definitions

Industry Standards & Definitions NEMA Designation Underwriters Laboratories Inc. UL 50 and UL 508 Canadian Standards Association CSA Standard C22.2 No 94 404 90 ADALET NEMA Designation Underwriters Laboratories Inc. UL 50 and UL 508 Canadian

More information

Power-Bond CHEMICAL PUMP & DUAL CARTRIDGE PRODUCT DESCRIPTION PRODUCT DESCRIPTION MIXING GUIDELINES POWER-BOND MATERIAL PROPERTIES

Power-Bond CHEMICAL PUMP & DUAL CARTRIDGE PRODUCT DESCRIPTION PRODUCT DESCRIPTION MIXING GUIDELINES POWER-BOND MATERIAL PROPERTIES 184 Power-Bond PUMP & DUAL CARTRIDGE BASE MATERIAL Solid Concrete, Block, Brick, Stone or Masonry SIZE RANGE 3" to Anchor Rod. No. 3 to No. 8 Reinforcing Bar Upon completion of mixing, pull the plunger

More information

DIVISION OF WASTE MANAGEMENT RESIDENTIAL VAPOR INTRUSION SCREENING CONCENTRATIONS (March, 2016)

DIVISION OF WASTE MANAGEMENT RESIDENTIAL VAPOR INTRUSION SCREENING CONCENTRATIONS (March, 2016) Note: The Residential screening level below or site specific screening concentrations (utilizing site specific attenuation and exposure factors) can be used. In either case the site s remedy must include

More information

Ocal. PVC-Coated Products. Products for corrosive environments

Ocal. PVC-Coated Products. Products for corrosive environments Ocal TM Products for corrosive environments Polymeric Fixtures for Class I, Zone 2, Groups IIC, IIB, IIA, Wet and Marine Locations Hazlux 1 HID, Mogul Base, 50-175W Enclosed and gasketed Polymeric (fiberglass-reinforced

More information

Technical Tubing and Hose

Technical Tubing and Hose Technical Tubing and Hose Flexible Calibrated Tubing Calibrated Multi-Tubing Recoil Tubing and Hose Calibrated Braided Hose Accessories 4-2 4-3 Technical Tubing and Hose Technical Tubing & Hose Technical

More information

Thermo Scientific Syringes and Filters

Thermo Scientific Syringes and Filters Thermo Scientific Syringes and Filters Titan3 and Target2 Syringe Filters Sample preparation with Thermo Scientific Titan3 and Thermo Scientific Target2 syringe filters help provide consistent and reliable

More information

Tubes et tuyaux techniques Polígono Indutrial O Rebullón s/n Mos - España -

Tubes et tuyaux techniques Polígono Indutrial O Rebullón s/n Mos - España - Technical Tubes et tuyaux techniques Tubing & Hose Flexible Tubes souples Calibrated calibrés Tubing 3-13 Polígono Indutrial O Rebullón s/n. 31 - Mos - España - rodavigo@rodavigo.com Fireproof High Resistance

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of death, injury or property damage from fire, electric shock,

More information

Surface drainage systems introduction. Area (m2) Fig. 4 31,5 28,5 25,5 22,5 19,5 16,5 13,5 10,5 7,5 4,5 1,5

Surface drainage systems introduction. Area (m2) Fig. 4 31,5 28,5 25,5 22,5 19,5 16,5 13,5 10,5 7,5 4,5 1,5 31,5 30 125 mm/hours 100 mm/hours 75 mm/hours 28,5 27 25,5 24 22,5 50 mm/hours 40 mm/hours 21 19,5 18 16,5 15 13,5 12 7. catch BaSinS covers GrillS 8. rainwater GullieS Area (m2) Total discharge qt (l/sec)

More information

HDPE Chemical Resistance Guide

HDPE Chemical Resistance Guide A Acetaldehyde S O Acetic acid (1-10%) S S Acetic acid (10-60%) S O Acetic acid (80-100%) S O Acetic anhydride S S Acetone S S Acids (aromatic) S S Acrylic emulsions S S Adipic acid S S Aluminum chloride

More information

Plastic Extruders Limited Russell Gardens, Wickford, Essex,SS11 8DN England. TEL: +44 (0) FAX: +44 (0)

Plastic Extruders Limited Russell Gardens, Wickford, Essex,SS11 8DN England. TEL: +44 (0) FAX: +44 (0) Plastic Extruders Limited Russell Gardens, Wickford, Essex,SS11 8DN England. TEL: +44 (0)1268 571116 FAX: +44 (0)1268 560027 sales@plastex.co.uk THE CHEMICAL RESISTANCE OF P.V.C. November 2003 Introduction

More information

DuPont Zytel 73G30HSL BK261

DuPont Zytel 73G30HSL BK261 Product Information PRODUCT INFORMATION Common features of Zytel nylon resin include mechanical and physical properties such as high mechanical strength, excellent balance of stiffness and toughness, good

More information

Polyethylene High Integrity Container Overpack Handling Procedure

Polyethylene High Integrity Container Overpack Handling Procedure Polyethylene High Integrity Container Overpack Handling Procedure Revision 14 Authored By: Signature on File 5/5/08 Carl McGovern, Principal Engineer Date Reviewed By: Signature on File 5/12/08 Sam Pearson,

More information

Epoxy Resin Specification Information

Epoxy Resin Specification Information Epoxy Resin Specification Information Epoxy Resin products are generally specified in sections 11600 and 12345 of most equipment specifications. Architectural Specification EPOXY RESIN WORK SURFACES shall

More information

PPH Pressed and Planed Sheet

PPH Pressed and Planed Sheet Product information Product full identity: Polypropylene Homopolymer PPH is light weight (SG 0.91) has improved chemicalresistance, stiffness, improved higher working temperature compared to PPC (0 C to

More information

PE300 Profiles Extruded

PE300 Profiles Extruded Product information Product full identity: High Density Polyethylene PE300 is a lightweight (SG 0.96) and strong material that has excellent sliding properties, good chemical resistance, low moisture absorption

More information

Draeger-Tubes and accuro Pump

Draeger-Tubes and accuro Pump Draeger-Tubes and accuro Pump Trusted Technology that s ahead of its time Accurate Easy to read Flexible Fast Specific Easy to use Maintenance free Multi-Gas Detector accuro pump One handed operation What

More information

INTRODUCTION CHEMCAST PMG ULTRA

INTRODUCTION CHEMCAST PMG ULTRA INTRODUCTION CHEMCAST PMG ULTRA is a unique high impact, fabricator friendly acrylic sheet with an improved formulation designed to accommodate the needs of the most demanding fabricators and builders.

More information

Altaflo is an innovative producer of high performance fluoropolymer and fluoroplastic tubing and pipe.

Altaflo is an innovative producer of high performance fluoropolymer and fluoroplastic tubing and pipe. Altaflo is an innovative producer of high performance fluoropolymer and fluoroplastic tubing and pipe. All Altaflo products are manufactured using 100% virgin grade high performance resins to provide the

More information

Compact and Light. Stainless Steel 316 Fittings. 65 to 260 C (Swivel elbow: 5 to 150 C) 24 g. 9 models 5 models Inch sizes have been added. Approx.

Compact and Light. Stainless Steel 316 Fittings. 65 to 260 C (Swivel elbow: 5 to 150 C) 24 g. 9 models 5 models Inch sizes have been added. Approx. Stainless Steel 31 Fittings Series Compact and ight Dimensions pprox.44% 00-02 pprox.3% 00-02 ore configuration variations models models sizes have been added. aterial Rubber material is not used. (Except

More information

PE300 Sheet Extruded. Product information. Applications. This document contains. Product full identity: Properties.

PE300 Sheet Extruded. Product information. Applications. This document contains. Product full identity: Properties. Product information Product full identity: High Density Polyethylene PE300 is a lightweight (SG 0.96) and strong material that has excellent sliding properties, good chemical resistance, low moisture absorption

More information

PE300 Rod Extruded. Product information. Applications. This document contains. Product full identity: Properties.

PE300 Rod Extruded. Product information. Applications. This document contains. Product full identity: Properties. Product information Product full identity: High Density Polyethylene PE300 is a lightweight (SG 0.96) and strong material that has excellent sliding properties, good chemical resistance, low moisture absorption

More information

MaxCell Technical Manual. Design Parameters 4G Product Line

MaxCell Technical Manual. Design Parameters 4G Product Line MaxCell Technical Manual Design Parameters 4G Product Line 4G Materials of Construction 4G Fabric Warp - Polyester Monofilament Diameter = 0.23 +/- 0.02 mm Denier = 520 +/- 25 Filling - Nylon 6 Monofilament

More information

THE RIGHT GLOVE FOR THE JOB SM

THE RIGHT GLOVE FOR THE JOB SM THE RIGHT GLOE FOR THE JOB SM PERMEATION & DEGRADATION TEST DATA Provided data and recommendations are intended as guides only. Work practices and conditions vary and are beyond our control. It is impossible

More information

Appendix F: Hazardous Gases and Vapors

Appendix F: Hazardous Gases and Vapors Appendix F: Hazardous Gases and Vapors The following pages contain excerpts from the National Fire Protection Association (NFPA) publication NFPA 497M Classification of Gases, Vapors, and Dusts for Electrical

More information

Spectra/Por Biotech Dialysis Membranes Cellulose Ester (CE) Regenerated Cellulose (RC)

Spectra/Por Biotech Dialysis Membranes Cellulose Ester (CE) Regenerated Cellulose (RC) Spectra/Por Biotech Dialysis Membranes Cellulose Ester (CE) Regenerated Cellulose (RC) Product Information & Operating Instructions Table of Contents Introduction................................2 Applications......................................2

More information

Balston OEM Disposable Filter Solutions

Balston OEM Disposable Filter Solutions Balston OEM Disposable Filter Solutions Parker Hannifin Corporation, the leader in separation and filtration technologies, is pleased to present a brochure designed to help OEM customers choose the best

More information

Rigid PVC Pipes (upvc Rigid Pipes)

Rigid PVC Pipes (upvc Rigid Pipes) Rigid PVC Pipes (upvc Rigid Pipes) Advantages of PVC Pipes PVC due to non-corrosive in nature and unaffected by chemicals, electrolytic and ironic corrosion can stay for very long time than other pipes

More information

Hammer-Capsule CHEMICAL PRODUCT DESCRIPTION SUGGESTED SPECIFICATION APPROVALS AND LISTINGS HAMMER CAPSULE SPECIFICATIONS

Hammer-Capsule CHEMICAL PRODUCT DESCRIPTION SUGGESTED SPECIFICATION APPROVALS AND LISTINGS HAMMER CAPSULE SPECIFICATIONS 22 INSTALLATION OF ANCHORS OVERHEAD Prior to installing adhesive anchors overhead or in walls, consult with the governing building authority to determine the requirements for fire safety guidelines. The

More information

SENSORS LIGHT CURTAINS SG-IP69K SERIES SAFETY ACCESSORIES FEATURES APPLICATIONS CARATTERISTICHE

SENSORS LIGHT CURTAINS SG-IP69K SERIES SAFETY ACCESSORIES FEATURES APPLICATIONS CARATTERISTICHE LIGHT CURTAINS SAFETY ACCESSORIES SG-IP69K SERIES The SG-IP69K accessory, is a PMMA acrylic tube used to protect and seal the safety light curtains of SG2, SG4 and SG BODY COMPACT series. Thanks to SG-

More information

SIGRAFLEX Gaskets P Resistance to Chemical Media

SIGRAFLEX Gaskets P Resistance to Chemical Media SIGRAFLEX Gaskets P Resistance to Chemical Media Chemical Resistance of SIGRAFLEX Flexible Graphite, Stainless Steel and PTFE A distinction is made between four cases: 1. Resistant 2. Not resistant 3.

More information

Manufacturers declaration of performance

Manufacturers declaration of performance Trespa International B.V. P.O. Box 110, 6000 AC Weert Wetering 20, 6002 SM Weert, The Netherlands Tel.: 31 (0) 495 458 358, Fax: 31 (0) 495 458 570 www.trespa.com Manufacturers declaration of performance

More information

260 c. Fluoropolymer Tubing. Max. operating temperature: 22 size variations. 4 color variations. New. Series TLM/TILM PFA. 1/8" to 1 1/4" (9 sizes)

260 c. Fluoropolymer Tubing. Max. operating temperature: 22 size variations. 4 color variations. New. Series TLM/TILM PFA. 1/8 to 1 1/4 (9 sizes) Fluoropolymer ew PFA RoHS Max. operating temperature: 20 c 22 size variations Metric size Straight ø2 to ø25 (13 sizes) m, m, 50 m, 0 m Inch size 2m Straight 4 color variations 1/8" to 1 1/4" (9 sizes)

More information

AP Chemistry Reaction Set

AP Chemistry Reaction Set Class: Date: AP Chemistry Reaction Set 2009-2010 Other 1. Pure solid phosphorus (white form) is burned in air. (2002) 2. Sulfur dioxide gas is bubbled into distilled water. (2001) 3. A drop of potassium

More information

Balston OEM Disposable Filter Solutions

Balston OEM Disposable Filter Solutions Balston OEM Disposable Filter Solutions Parker Hannifin Corporation, the leader in separation and filtration technologies, is pleased to present a brochure designed to help OEM customers choose the best

More information

Using PVC Sheet Piling for Organic Chemical Cut-off and Containment Barriers. A Whitepaper by: Steve Hargrave

Using PVC Sheet Piling for Organic Chemical Cut-off and Containment Barriers. A Whitepaper by: Steve Hargrave Using PVC Sheet Piling for Organic Chemical Cut-off and Containment Barriers A Whitepaper by: Steve Hargrave Using PVC Sheet Piling for Organic Chemical Cut-off and Containment Barriers Polyvinyl chloride

More information

CATALOG HHD ELECTROMAGNETIC FLOWMETER

CATALOG HHD ELECTROMAGNETIC FLOWMETER HHD ELECTROMAGNETIC FLOWMETER DESCRIPTION OF PRODUCTS Electromagnetic flowmeter is a kind of inductional instrument designed by Faraday s law of electromagnetic induction to measure flow of conductive

More information

TPU CHEMICAL RESISTANCE CHART

TPU CHEMICAL RESISTANCE CHART TPU CHEMICAL RESISTANCE CHART Ratings Guide Good Should have little or no effect on the material at the given concentration and temperature Moderate Some effect on the material at the given concentration

More information

DuPont Zytel 73G45 BK263

DuPont Zytel 73G45 BK263 Product Information PRODUCT INFORMATION Common features of Zytel nylon resin include mechanical and physical properties such as high mechanical strength, excellent balance of stiffness and toughness, good

More information