DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0.

Size: px
Start display at page:

Download "DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0."

Transcription

1 Magnetic Inductive Flowmeter for conductive fluids measuring monitoring analysing MH Measuring range: m 3 /h ccuracy: ± 0.3% of reading ± 0.01% x Q max p max : PN40; t max : C O O Connection: flange , NSI ½"... 48" ining material: hard rubber, soft rubber, PTFE / PF Outputs: analogue with HRT, pulses and status S5 KOBO companies worldwide: RGENTIN, USTRI, USTRI, BEGIUM, BUGRI, CN, CHIE, CHIN, COoMBI, CZECHI, EGYPT, FRNCE, GERMNY, GRET BRITIN, HUNGRY, INI, INONESI, ITY, MYSI, MEXICO, NETHERNS, PERU, PON, Republic of Korea, ROMNI, SINGPORE, SPIN, SWITZERN, TIWN, THIN, TUNISI, turkey, US, VIETNM KOBO Messring GmbH Nordring Hofheim/Ts. Head Office: +49(0) (0) info.de@kobold.com 1

2 escription The KOBO MH flowmeter is used to measure and monitor the volume flow rate of fluids, pulps, pastes and other electrically conductive materials, without loss of pressure. When an electrically conductive medium passes through a directional magnetic field, a voltage is induced in accordance with Faraday s aw of Induction. The size of this measurement voltage is proportional to the mean rate of flow and consequently also to the volume flow rate. flowmeter consists of a sensor that picks up the measuring signal generated from the induced voltage, and a transducer that converts this signal into a standardised output signal (4-20 m or pulses). The measurement transducer can be affixed to the sensor or mounted separately. Pressure, temperature, density and viscosity do not affect the volume measurement. Solid fractions and gas bubbles should be avoided. The significant properties exhibited by MH include: Great choice of linings O O Stainless, Hastelloy, tantalum or platinum electrodes Wide variety of process connections Can be used in rough ambient conditions Fields of pplication cids, alkalis Pastes rinking water, waste water etc. Technical etails djustable measuring range terminal values: m /s Minimum conductivity: 5 µs /cm (for fluids in general) 20 µs/cm (demineralised water) ccuracy: ±0.3% of read. ± 0.01% x Q max Repeat accuracy: ±0.15% of read. ± 0.005% x Q max (reference conditions: water, measured medium temperature of 22 C ±4K, ambient temperature 22 C ±2K, inlet path 10 x, outlet path 5 x, Q max at 10 m/s) Process temperature: C (hard rubber, soft rubber) C (PTFE); PF C (E-CTFE) mbient temperature: C, depending on process temperature Rated pressure: PN 40, (40 bar) (½"-12") PN 16, (16 bar) (½"-24") PN 10, (10 bar) PN 6, (6 bar) higher pressures on request Sensor materials inings: Hard rubber, soft rubber, PTFE, PF, E-CTFE Electrodes: Stainless, Hastelloy C4, tantalum, platinum, earth ring and other materials on request Housing: Enamelled (MH-1,MH-2, MH-5) stainless (MH-6) Process connection: Steel or stainless flange EN1092 and SME B16.5, wafer version, foodstuff, screw seal IN11851, Tri-Clamp, other connections on request Nominal sizes: other nominal sizes on request Protection type: IP 67, IP /

3 Technical etails(continued) Transducer UMF2(B) ssembly type: Compact or separate Housing: Enamelled die-cast aluminium Power supply: 115 V C, 50 / 60 Hz, 10 V 230 V C, 50 / 60 Hz, 10 V 24 V C 10 W Outputs nalogue: 1 x 0(4)-20 m, active, galvanically isolated Pulse output: Passive, galvanically isolated 24 V, 60 m Status: Passive, galvanically isolated 24 V, 60 m mbient temperature: C, depending on process temperature for compact version Protection type: IP 68 (EN60529) Communication: HRT iagnosis functions: Empty pipe recognition, flushing flow monitoring Electromagnetic compatibility: EMV directive 2004/108/EG 3

4 Measuring Range Flange Pressure rating PN Min. measuring range [m³/h] Max. measuring range [m³/h] 10* * * / / /16/ / / / / / / / SME lbs ½* ½* ½* ½ ¾ ¼ ½ ½ * Unit with PF-lining, with 6, 8 and 10 mm tube 4 1/

5 Order etails (Example: MH-1 15 H ) Model/ flangematerial MH-2 = stainless MH-1= enamelled MH-2 = stainless MH-5 2) = wafer version MH-6 3) = food connection Process connection 1) (flange acc. to EN Form B1) 06 5) = 10 / 6 mm, PN ) = 10 / 8 mm, PN ) = 10 / 10 mm, PN ) = 15, PN = 20, PN = 25, PN = 32, PN = 40, PN = 50, PN 40 C65 = 65, PN = 65, PN = 80, PN 40 C1H = 100, PN 16 1H = 100, PN 40 C1Z = 125, PN 16 1Z = 125, PN 40 C80 = 80, PN 16 C1F = 150, PN 16 1F = 150, PN 40 2H = 200, PN 10 C2H = 200, PN 16 2H = 200, PN 40 2F = 250, PN 10 2F = 250, PN 40 3H = 300, PN 10 C3H = 300, PN 16 3H = 300, PN 40 3F = 350, PN 10 C3F = 350, PN 16 4H = 400, PN 10 C4H = 400, PN 16 4F = 450, PN 10 5H = 500, PN 10 C5H = 500, PN 16 6H = 600, PN 10 C6H = 600, PN 16 E7H = 700, PN 6 E8H = 800, PN 6 E9H = 900, PN 6 ET0 = 1000, PN 6 ET2 = 1200, PN 6 H 4) 15 = 15 H 4) 20 = 20 H 4) 25 = 25 H 4) 32 = 32 H 4) 40 = 40 H 4) 50 = 50 H 4) 65 = 65 H 4) 80 = 80 H 4) 1H = 100 1) SME-flange class 150: code xx, SME-flange class 300: code Mxx (up to 1½ / 40), NSI flange not available for sizes 700, other process connections on request 2) Wafer version only for nominal width ; standard flange rating PN40 from and PN16 from ) Only valid with PTFE coating 4) For Tri-Clamp connection replace H with T 5) Only with PF and 3 x HC4 electrode 6) Only available with stainless electrode and stainless grounding electrode 11 7) Standard with electrode material and grounding electrode material 33. Not with stainless electrode. Process connection 300/12" with E- CTFE lining instead of PTFE, T max : 130 C 8) Only for PTFE liner and electrode material option 4, 5, and 7 9) Measuring electrode material and grounding electrode material should be identical ining H 6) = hard rubber W 6) = soft rubber T 7) = PTFE/ PF Measuring electrode material 9) 1 = stainless 3 = Hastelloy C4 4 = Titan 5 = tantalum 7 = platinum Earth electrode material 9) 0 8) = without 1 = stainless 3 = Hastelloy C4 4 = Titan 5 = tantalum 7 = platinum Versions/ cable lengths = compact, IP 67 B... H, IP 67 B = separate version/2.5 m C = separate version/5 m = separate version/10 m E = separate version/15 m F = separate version/ 20 m G = separate version/ 30 m H = separate version/ 50 m K... R, IP 68 K = separate version/2.5 m = separate version/5 m M = separate version/10 m N = separate version/15 m P = separate version/ 20 m Q = separate version/ 30 m R = separate version/ 50 m Electronics 1 = UMF2(B)- electronics with control unit, without HRT 2 = UMF2(B)- electronics with control unit, with HRT Power supply/ cable entry point 0 = 230 V C 4 = 115 V C 3 = 24 V C 5 = 230 V C 6 = 115 V C 8 = 24 V C 5

6 Order etails (Example: MH-1 J25 H ) Model/ flangematerial Process connection 1) (flange acc. to JIS RF flange B2220) ining Measuring electrode material 9) Earth electrode material 9) Versions/ cable lengths Electronics Power supply/ cable entry point J15 3) = 15,10K K15 3) = 15, 20K J20 = 20,10K K20 = 20,20K J25 = 25,10K K25 = 25, 20K J32 = 32, 10K K32 = 32, 20K J40 = 40, 10K = compact, IP 67 B... H, IP 67 B = separate version/2.5 m C = separate version/5 m MH-1= enamelled MH-2 = stainless MH-5 2) = wafer version K40 = 40, 20K J50 = 50, 10K K50 = 50, 20K J65 = 65, 10K K65 = 65, 20K J80 = 80, 10K K80 = 80, 20K J100 = 100, 10K K100 = 100, 20K J125 = 125, 10K K125 = 125, 20K J150 = 150, 10K K150 = 150, 20K J200 = 200, 10K H 4) = hard rubber W 4) = soft rubber 5) = PTFE/ PF 1 = stainless 3 = Hastelloy C4 4 = Titan 5 = tantalum 7 = platinum 0 8) = without 1 = stainless 3 = Hastelloy C4 4 = Titan 5 = tantalum 7 = platinum = separate version/10 m E = separate version/15 m F = separate version/ 20 m G = separate version/ 30 m H = separate version/ 50 m K... R, IP 68 K = separate version/2.5 m = separate version/5 m M = separate version/10 m N = separate version/15 m 1 = UMF2(B)- electronics with control unit, without HRT 2 = UMF2(B)- electronics with control unit, with HRT 0 = 230 V C 4 = 115 V C 3 = 24 V C 5 = 230 V C 6 = 115 V C 8 = 24 V C K200 = 200, 20K J250 = 250, 10K K250 = 250, 20K P = separate version/ 20 m Q = separate version/ 30 m J300 = 300, 10K K300 = 300, 20K R = separate version/ 50 m J350 = 350, 10K K350 = 350, 20K 1) bove 350mm & other rating on request 2) Wafer version only for nominal width ; JIS flange type on request 3) Only valid with PTFE coating 4) Only available with stainless electrode and stainless grounding electrode 11 5) Standard with electrode material and grounding electrode material 33. Not with stainless electrode. Process connection 300/12" with E-CTFE lining instead of PTFE, T max : 130 C 6

7 imensions Transducer UMF2(B) Connection box for sensor, separate version d M20x1,5 Sensor, flange connection I PN SME NSI d I Weight* [kg] 10/6 40 ½" /8 40 ½" ½" ½" ¾" " ¼" ½" " /40 2½" /40 3" /40 4" /40 5" /40 6" /16/40 8" /40 10" /16/40 12" /16 14" /16 16" /16 18" on request on request on request on request on request /16 20" /16 24" " on request " " on request " " * Weights of the sensors are only approximate values, including the weight of the electronics approx. 2.4 kg 7 1/

8 imensions (continuation) Sensor, wafer flange PN Weight* [kg] * Weights of the sensors are only approximate values, including the weight of the electronics approx. 2.4 kg Food connection acc. to IN PN Connection Tri-Clamp (ISO) PN10 (ISO mm) (ISO Inch) ½" ¾" " ½" " ½" " "

DMH. Magnetic Inductive Flowmeter. for conductive fluids

DMH. Magnetic Inductive Flowmeter. for conductive fluids Magnetic Inductive Flowmeter for conductive fluids measuring monitoring analysing MH Measuring range: 0.05 40376 m 3 /h ccuracy: ± 0.3% of reading ± 0.01% x Q max p max : PN40; t max : -20... +150 C Connection:

More information

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application: SI-02 Electromagnetic Flowmeter for General Applications Description: Features / Universally applicable / Separate or compact measuring transmitter / Variety of lining material / DN15 to DN2000 / DIN-

More information

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max Flap Flowmeter for liquids measuring monitoring analysing TSK Range: 0.5-3.5 200-1500 m 3 /h Accuracy: ± 2.0 of reading p max : PN 40, t max: -40 +300 C Connection: wafer flange DN 25 500 Material: stainless

More information

Electromagnetic flowmeters. dg: NEW. Sensor MUT 2200 EL DS100-2-ENG 1/12

Electromagnetic flowmeters. dg:   NEW. Sensor MUT 2200 EL DS100-2-ENG 1/12 Electromagnetic flowmeters dg: www.oryana.com.ar NEW Sensor MUT EL DSENG 1/ Sensor MUT EL MUT EL sensors represent the state of the art of EUROMAG INTERNATIONAL production for water cycle and process applications.

More information

TSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max

TSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max Flap Flow Meter for Liquids measuring monitoring analysing TSK Range: 0.5-3.5 200-1500 m 3 /h Accuracy: ± 2.0 of reading p max : PN 40, t max: -40 +300 C Connection: wafer flange DN 25 500 Material: stainless

More information

Electromagnetic Flange Type BTU METERS. eflow 800H SERIES. Size DN10 to DN1200 DESCRIPTION APPLICATION FEATURES

Electromagnetic Flange Type BTU METERS. eflow 800H SERIES. Size DN10 to DN1200 DESCRIPTION APPLICATION FEATURES DESCRIPTION eflow 800H series is flange type Electromagnetic Heat or BTU meter that can be used for measuring energy consumption in heating or cooling application for HVAC and other energy measurement

More information

ALTOFLUX IFS 4000/4005

ALTOFLUX IFS 4000/4005 KROHNE 03/2002 7.02351.22.00 GR ALTOFLUX IFS 4000/4005... result of more than 40 years experience with electromagnetic flowmeters Liner made of KROHNE Teflon -PFA or other fluorines Dimensionally stable,

More information

Bypass Level Indicators

Bypass Level Indicators Bypass Level Indicators measuring monitoring analysing NBK -03/ -06/ -07/ -10/ -31/ -32/ -33 OO Measuring length: single-part max. 5500 mm over 5500 mm two-part or multipart OO Pressure: max. PN 320 /

More information

FLOMID FX Electromagnetic Flowmeter

FLOMID FX Electromagnetic Flowmeter FLOMID FX Electromagnetic Flowmeter Introduction Modular design in two versions: Compact, sensor and electronics unit forming a single unit Separate, sensor and electronics separated, joined by a cable

More information

OM... Screw-Type Volumetric Flow Meter. for Viscous Media. Measuring ranges: l/min liquid

OM... Screw-Type Volumetric Flow Meter. for Viscous Media. Measuring ranges: l/min liquid Screw-Type Volumetric Flow Meter for Viscous Media measuring monitoring analysing OM... Measuring ranges: 0.-0... 0-000 l/min liquid OMeasuring O accuracy: ± 0.% of span : 00 ± 0.% of span : 0 p max :

More information

CATALOG HHD ELECTROMAGNETIC FLOWMETER

CATALOG HHD ELECTROMAGNETIC FLOWMETER HHD ELECTROMAGNETIC FLOWMETER DESCRIPTION OF PRODUCTS Electromagnetic flowmeter is a kind of inductional instrument designed by Faraday s law of electromagnetic induction to measure flow of conductive

More information

CIRRUS MAGNETIC FLOW METER CLA1-MF

CIRRUS MAGNETIC FLOW METER CLA1-MF CLA1-MF CLA1-MF MAGNETIC FLOW METER DESCRIPTION CLA1-MF Electromagnetic flow meters as they are called, operates on Faraday's law of electromagnetism to measure flow of conductive liquids. These flow meters

More information

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES The manufacturer guarantees only English text. Available on our web site:

More information

SENSOR MUT1000EL. Electromagnetic flowmeter. The wafer electromagnetic flowmeter DS120-2-ENG

SENSOR MUT1000EL. Electromagnetic flowmeter. The wafer electromagnetic flowmeter DS120-2-ENG SENSOR MUT1000EL Electromagnetic flowmeter The wafer electromagnetic flowmeter DS120-2-ENG Sensor MUT1000EL MUT1000EL sensors represent the state of the art of Euromag International production for water

More information

High-Performance Magnetic Flowmeter

High-Performance Magnetic Flowmeter MESURE TODY. ENSURE TOMORROW. SpireMag Series MG888 No Moving Parts! Plug &Play! Minimal Straight Pipe! Telemetry Ready! SpireMag Series MG888 high-performance magnetic flowmeter accurately measures the

More information

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring Level Measurement and Monitoring FN04 Liquid level sensor with continuous detection Level measurement unaffected by foam formation, conductivity, pressure or temperature Remote indication over very long

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available

More information

ISI Marked Class-A & Class-B Water Meters as per IS: 779 / 1994 Conforming to ISO 4064 Standard for Cold Water Meters

ISI Marked Class-A & Class-B Water Meters as per IS: 779 / 1994 Conforming to ISO 4064 Standard for Cold Water Meters Product Range ISI Marked Class-A & Class-B Water Meters as per IS: 779 / 1994 Conforming to ISO 4064 Standard for Cold Water Meters Electromagnetic flow meters for water & waste water applications IBR

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available

More information

OPTIMASS 7400 Technical Datasheet

OPTIMASS 7400 Technical Datasheet OPTIMASS 7400 Technical Datasheet Sensor for mass flow The optimum meter for demanding applications A single straight measuring tube Choice of 4 tube materials The documentation is only complete when used

More information

PCL Series Electromagnetic Flowmeters

PCL Series Electromagnetic Flowmeters PCL Series Electromagnetic Flowmeters Introduction PCL series electromagnetic flowmeters, composed of sensor and converter, work based on Faraday s law of electromagnetic induction. It is used to measure

More information

PCL Series Electromagnetic Flowmeters

PCL Series Electromagnetic Flowmeters PCL Series Electromagnetic Flowmeters Introduction PCL series electromagnetic flowmeters, composed of sensor and converter, work based on Faraday s law of electromagnetic induction. It is used to measure

More information

PCL Series Electromagnetic Flowmeters

PCL Series Electromagnetic Flowmeters PCL Series Electromagnetic Flowmeters Introduction PCL series electromagnetic flowmeters, composed of sensor and converter, work based on Faraday s law of electromagnetic induction. It is used to measure

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 May 2009 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available

More information

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h... All Metal Variable Area Flowmeter for liquids and gases measuring monitoring analysing : 0.1-1 l/h... 20-200 l/h water 5 - Nl/h... 600-6000 Nl/h Accuracy: ±3 % of full p max : 420 bar; t max : 130 C OConnection:

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The MAG is an electromagnetic flow sensor in a large variety that meets the demands of almost every flow application. Benefits Wide range of sizes: DN 15 to DN 2000 (½ to 78 ) The flexible design

More information

Electromagnetic Flowmeter

Electromagnetic Flowmeter LMF LMF11 General Applications LMF11B Battery Operated LMF12 Heat Meter (BTU) LMF13 Sanitary Type LMF14 Insertion Type LMF14B Insertion Type Battery Operated Products Performance & Features Product Description

More information

Battery-Powered Magnetic Flow Meter

Battery-Powered Magnetic Flow Meter MEASURE TODAY. ENSURE TOMORROW. SpireMag Series MAG888-DC Standalone No Wiring Plug & Play Telemetry Ready Integral type Integral type with GPRS Wireless Remote Type The SpireMag series MAG888-DC flowmeter

More information

Battery-Powered Magnetic Flow Meter

Battery-Powered Magnetic Flow Meter MEASURE TODAY. ENSURE TOMORROW. SpireMag Series MAG888-DC Standalone No Wiring Plug & Play Telemetry Ready Integral type Integral type with GPRS Wireless Remote Type The SpireMag series MAG888-DC flowmeter

More information

TTL-Exd. Thermocouple Thermometers. Ignition Protection Exd. NiCr-Ni or Fe-CuNi thermocouples. Output: sensor or analogue 4-20 ma

TTL-Exd. Thermocouple Thermometers. Ignition Protection Exd. NiCr-Ni or Fe-CuNi thermocouples. Output: sensor or analogue 4-20 ma Thermocouple Thermometers Ignition Protection Exd measuring monitoring analysing TTL-Exd T2 O O Measuring ranges: max. 1100 C OO NiCr-Ni or Fe-CuNi thermocouples OO Output: sensor or analogue 4-20 ma O

More information

Continuous Level Sensor CONDURIX 31.1

Continuous Level Sensor CONDURIX 31.1 Continuous Level Sensor CONDURIX CONDURIX The Continuous Measurement of Filling Levels according to the Potentiometric Measuring Principle The CONDURIX Sensor supplies information on filling levels of

More information

DON-H. Oval Gear Flowmeter for High Pressures. for Low and High Viscosity Liquids

DON-H. Oval Gear Flowmeter for High Pressures. for Low and High Viscosity Liquids Oval Gear Flowmeter for High Pressures for Low and High Viscosity Liquids measuring monitoring analyzing DON-H Measuring : 0.13 9.5 GPH to 0.26 10.6 GPM Viscosity : up to 1000 cp (Higher on Request) ccuracy:

More information

MAN-U. Differential Pressure Gauges. for high static pressures up to 200 bar. Housing: 100 mm, 150 mm

MAN-U. Differential Pressure Gauges. for high static pressures up to 200 bar. Housing: 100 mm, 150 mm Differential Pressure Gauges for high static pressures up to 200 bar measuring monitoring analysing MAN-U Housing: 100 mm, 150 mm Material Housing: stainless steel Connection: stainless steel Movement:

More information

SpireMag Series MAG888

SpireMag Series MAG888 MEASURE TODAY. ENSURE TOMORROW. SpireMag Series MAG888 No Moving Parts! Plug & Play! Minimal Straight Pipe Required! Telemetry Ready! The SpireMag Series MAG888 highperformance magnetic flowmeter accurately

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Supplementary electronics for 4-wire connection Structural design Dimensions (W x H x D) in mm (inch) Electrical connection 80x10x60 (3.15x4.7x.36) Screw terminals (Pg 13.5 cable inlet) or Han

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO from 0... 00 mbar up to 0... 0 bar Output signals

More information

SpireMag Series MAG888

SpireMag Series MAG888 MEASURE TODAY. ENSURE TOMORROW. SpireMag Series MAG888 No Moving Parts Plug &Play Minimal Straight Pipe Required Telemetry Ready The SpireMag Series MAG888 highperformance magnetic flowmeter accurately

More information

DATA SHEET MS2500_EN-IT_DS006REV14

DATA SHEET MS2500_EN-IT_DS006REV14 DATA SHEET MS 2500 INDEX TECHNICAL DATA 2 97/23/CE PED DIRECTIVE 3 OVERALL DIMENSIONS 4 SENSOR VERSIONS/JUNTION BOX 7 SEPARATE VERSION 8 INSTALLATION RECOMMENDATIONS 9 RECOMMENDED INSTALLATION PROCEDURE

More information

DATA SHEET MS2500_EN-IT_DS006REV17

DATA SHEET MS2500_EN-IT_DS006REV17 DATA SHEET MS 2500 INDEX TECHNICAL DATA 2 97/23/CE PED DIRECTIVE 3 OVERALL DIMENSIONS 4 SENSOR VERSIONS/JUNTION BOX 7 SEPARATE VERSION 8 INSTALLATION RECOMMENDATIONS 9 RECOMMENDED INSTALLATION PROCEDURE

More information

POLYPROPYLENE SENSOR LIGHT WEIGHT SENSOR COMPLETELY IN POLYPROPYLENE

POLYPROPYLENE SENSOR LIGHT WEIGHT SENSOR COMPLETELY IN POLYPROPYLENE POLYPROPYLENE SENSOR LIGHT WEIGHT SENSOR COMPLETELY IN POLYPROPYLENE The manufacturer guarantees only English text. Available on our web site: www.isomag.eu INDEX TECHNICAL DATA... 3 OVERALL FEATURES...

More information

VersaFlow Coriolis 200 Sensor for Mass Flow Specifications

VersaFlow Coriolis 200 Sensor for Mass Flow Specifications VersaFlow Coriolis 200 Sensor for Mass Flow Specifications 34-VF-03-12 June 2011 The Solution for Bulk Mass Flow Measurement The VersaFlow Coriolis 200 has been developed to meet the demanding transfer

More information

OPTIMASS 7400 Technical Datasheet

OPTIMASS 7400 Technical Datasheet OPTIMASS 7400 Technical Datasheet Sensor for mass flow The optimum meter for demanding applications A single straight measuring tube Choice of 4 tube materials The documentation is only complete when used

More information

MFR / MFF / MFT. Magnetic Filters and Dirt Traps : PN 40. p max. t max. : +200 C OScrew O thread: G ¼... G 4

MFR / MFF / MFT. Magnetic Filters and Dirt Traps : PN 40. p max. t max. : +200 C OScrew O thread: G ¼... G 4 Magnetic Filters and Dirt Traps measuring monitoring analysing MFR / MFF / MFT OO p max : PN 40 OO t max : +200 C OScrew O tread: G ¼... G 4 OScrew O tread: Rp 1... Rp 2 OFlanges: O DN 50... DN 200 OSolder

More information

ELECTROMAGNETİC FLOWMETERS

ELECTROMAGNETİC FLOWMETERS ELECTROMAGNETİC FLOWMETERS DN Working principle based on electromagnetic induction law Ability to measure with variable diameter of 151200mm Long-term perfect work Stainless body construction Suitable

More information

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

Diaphragm seal with flange connection With internal diaphragm, threaded design Model Diaphragm seals Diaphragm seal with flange connection With internal diaphragm, threaded design Model 990.12 WIKA data sheet DS 99.31 for further approvals see page 7 Applications Aggressive, contaminated,

More information

EMF-B split type EMF-A integrative type EMF-A integrative type Product applicability

EMF-B split type EMF-A integrative type EMF-A integrative type Product applicability WP-MF-/(integrative /split) universal type electromagnetic flow meter MF- split type MF- integrative type MF- integrative type Product applicability lectromagnetic flow meter is constitut by the primary

More information

Oval Wheel Meter Innovations from 1932 until today. Description. Measuring Ranges. Technical Data. OR ,03-1 l/min G¼. OR ,2-7 l/min G¼

Oval Wheel Meter Innovations from 1932 until today. Description. Measuring Ranges. Technical Data. OR ,03-1 l/min G¼. OR ,2-7 l/min G¼ Oval Wheel Meter Innovations from 1932 until today Positive Displacement Meter: Flowal Series OR-MFE Measurement of flowrate, volume or mass ccuracy 0,5% of actual value Pulse and analog output Noiseless

More information

ZDM. Positive Displacement Flowmeter

ZDM. Positive Displacement Flowmeter Positive Displacement Flowmeter measuring monitoring analyzing ZDM Viscosities up to 100,000 cst Accuracy: ±0.3% of Flow Pressure: to 6500 PSIG Can Detect Flow Direction Handles a Variety of Lubricating

More information

Coriolis Mass Flowmeter serving thousands of worldwide applications

Coriolis Mass Flowmeter serving thousands of worldwide applications RHM 08 - A standard Coriolis Mass Flowmeter serving thousands of worldwide applications The RHM 08 can measure flow rates up to 50 kg/min (110 lb/min) with temperatures in excess of 400 C and pressures

More information

DeltaMass MT Series Mass Flow & Density Sensor

DeltaMass MT Series Mass Flow & Density Sensor EMCO UniMag TM Magnetic Flowmeters DeltaMass MT Series Mass Flow & Density Sensor 4-24 in. (100-600 mm) The DeltaMass Flowmeter combines a UniMag magnetic flowmeter and a low level gamma ray density sensor

More information

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2. SITRANS P DSIII Pressure Transmitters All versions of the SITRANS P transmitter, DS III series, are smart two-wire transmitters The output signal is a load-independent direct current of 4 to 20 ma proportional

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Technical Datasheet. Specification. The superior solution. Highlights. Applications.

VersaFlow Coriolis 1000 Mass Flow Sensor Technical Datasheet. Specification. The superior solution. Highlights. Applications. VersaFlow Coriolis 1000 Mass Flow Sensor Technical Datasheet 34-VF-03-03 29 th May, 2009 Specification The superior solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight

More information

Coriolis Mass Flowmeter FCM2000

Coriolis Mass Flowmeter FCM2000 Data Sheet Coriolis Mass Flowmeter Coriolis Mass Flowmeters are used for the measurement of the mass flow and density to the highest accuracy. The fluid need not be electrically conductive. No moving parts,

More information

Rotating Vane Level Monitor

Rotating Vane Level Monitor Rotating Vane Level Monitor measuring monitoring analysing Fixed shaft or cable shaft Bulk materials: 0.2 to 2.5 t/m 3 Max. particle sizes: 50 mm Temperature: max. 85 C Max. filling level: 5 m pmax: 0

More information

TOPAS PMG / PMH Hydraulic sensor Hot water

TOPAS PMG / PMH Hydraulic sensor Hot water TOPAS PMG / PMH Hydraulic sensor Hot water Applications The hydraulic sensors form part of a heat meter and operate according to the multiple-jet measuring principle. Features Insensitive to turbulences

More information

BM ULTRA COMPACT/REMOTE UC SERIES ULTRASONIC LEVEL INSTRUMENTS (Compact/Remote version)

BM ULTRA COMPACT/REMOTE UC SERIES ULTRASONIC LEVEL INSTRUMENTS (Compact/Remote version) M ULTR COMPCT/REMOTE UC SERIES ULTRSONIC LEVEL INSTRUMENTS (Compact/Remote version) ESCRIPTION The ultrasonic impulses generated from transducers antenna system, which travel at the speed of sound, come

More information

VLM10 In-line Vortex Mass Flow Meter

VLM10 In-line Vortex Mass Flow Meter VLM10 In-line Vortex Mass Flow Meter Description The VLM10 in-line vortex flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process

More information

TURBINE METER RQ Series 1 and 2

TURBINE METER RQ Series 1 and 2 1. IDENTIFICATION Manufacturer Bopp & Reuther Messtechnik Am Neuen Rheinhafen 4 67346 Speyer / Germany Phone: +49 6232 657-0 Fax: +49 6232 657-505 Product type Indirect volume meter Product name Turbine

More information

All Stainless Steel Bourdon Tube Pressure Gauges

All Stainless Steel Bourdon Tube Pressure Gauges All Stainless Steel Bourdon Tube Pressure Gauges acc. to N 871 for Industrial Applications measuring monitoring analysing Housing: 6 mm, 1 mm, 16 mm (option: 8 mm) onnection: G 1 (6 mm housing) G 1 2 (1,

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Output

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 00 bar Output

More information

MFR / MFF / MFT. Magnetic Filters and Dirt Traps : PN40 : +200 C. Rp1...Rp2. OO p max. OO t max. OO Screw thread: G¼...G4. OO Flanges: DN50...

MFR / MFF / MFT. Magnetic Filters and Dirt Traps : PN40 : +200 C. Rp1...Rp2. OO p max. OO t max. OO Screw thread: G¼...G4. OO Flanges: DN50... Magnetic Filters and Dirt Traps measuring monitoring analysing MFR / MFF / MFT OO p max : PN40 OO t max : +200 C OO Screw tread: G¼...G4 OO Screw tread: Rp1...Rp2 OO Flanges: DN50...DN200 OO Solder connections:

More information

Large selection of standard versions. Special versions at customer request. Nominal sizes: 100, 125 and 150 mm

Large selection of standard versions. Special versions at customer request. Nominal sizes: 100, 125 and 150 mm Bi-metal Thermometers all Stainless Steel Construction measuring monitoring analysing TBE Fast response times Large selection of standard versions Special versions at customer request Nominal sizes: 100,

More information

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or

More information

All Stainless Steel Bourdon Tube Pressure Gauges

All Stainless Steel Bourdon Tube Pressure Gauges All Stainless Steel Bourdon Tube Pressure Gauges acc. to N 871 for Industrial Applications measuring monitoring analysing Housing: 6 mm, 1 mm, 16 mm (option: 8 mm) onnection: G 1 (6 mm housing) G 1 2 (1,

More information

Diaphragm pressure gauge

Diaphragm pressure gauge Diaphragm pressure gauge with switch function, NS 00/60,Type series BE2 Features Diaphragm pressure gauge with switch function High quality case with bajonet ring NS 00/60 per EN 837-3 S, alternative safety

More information

Diaphragm seal with flange connection With internal diaphragm Model

Diaphragm seal with flange connection With internal diaphragm Model Diaphragm seals Diaphragm seal with flange connection With internal diaphragm Model 990.26 WIKA data sheet DS 99.26 for further approvals see page 7 Applications Aggressive, highly viscous, crystallising

More information

Diaphragm seal with threaded connection Threaded design Model

Diaphragm seal with threaded connection Threaded design Model Pressure Diaphragm seal with threaded connection Threaded design Model 990.10 WIKA data sheet DS 99.01 for further approvals see page 6 Applications For aggressive, hot, corrosive, environmentally hazardous

More information

QGO Oxygen Sensor. Building Technologies HVAC Products

QGO Oxygen Sensor. Building Technologies HVAC Products 7 842 QGO20.000D17 QGO20.000D27 Oxygen Sensor QGO20.000... The QGO20... is an oxygen sensor designed for acquiring the residual oxygen content of flue gases in heat generation plant burning natural gas

More information

DVH. Multivariable Vortex Flowmeter

DVH. Multivariable Vortex Flowmeter Multivariable Vortex Flowmeter measuring monitoring analyzing DVH Measuring Ranges: 0.9...22 to 142...4270 GPM Water 1.8...18 to 2071...203,000 SCFM Air 6.5...52 to 6014...380,148 Lb/Hr Steam Accuracy:

More information

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass

More information

With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos.

With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos. průmyslová elektronika Capacitive level meters CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and

More information

Diaphragm Seal with flush diaphragm and flange acc.to EN or ASME B 16,5 Pressure gauge in stainless steel

Diaphragm Seal with flush diaphragm and flange acc.to EN or ASME B 16,5 Pressure gauge in stainless steel Ed.17.01 Design Diaphragm Seal with flush diaphragm and flange acc.to EN 1092-1 or ASME B 16,5 Pressure gauge in stainless steel Type Lower body Flush diaphragm with flange connection acc.to EN 1092-1

More information

LIQUID METER TYPE FMO

LIQUID METER TYPE FMO LIQUID METER TYPE FMO INNOVATORS IN FLOW TECHNOLOGY FLUX LIQUID METER TYPE FMO OVAL ROTOR DESIGN FLUX liquid meters type FMO are positive displacement flowmeters according to the oval rotor design. They

More information

Flow measurement of Liquids and Gases

Flow measurement of Liquids and Gases Flow measurement of Liquids and Gases Metallic construction Operates horizontally or vertically DN 40 to DN 500 Flow rate: - Water: 0.8 m 3 /h up to 1600 m 3 /h. - Air: 45 Nm 3 /h up to 24000 Nm 3 /h.

More information

VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features.

VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features. VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet 34-VF-03-12 October 2009 Specification The solution for bulk mass flow measurement The VersaFlow Coriolis 200 has been developed to meet

More information

Field IT Electromagnetic Flowmeter FSM4000

Field IT Electromagnetic Flowmeter FSM4000 ata Sheet 1S7U Field IT Electromagnetic Flowmeter FSM Level : Information Function Electromagnetic flowmeters can be used to accurately measure the flowrate of liquids, slurries, pastes and sludges with

More information

Field IT Electromagnetic Flowmeter FSM4000

Field IT Electromagnetic Flowmeter FSM4000 ata Sheet 1S7U Field IT Electromagnetic Flowmeter FSM Level : Information Function Electromagnetic flowmeters can be used to accurately measure the flowrate of liquids, slurries, pastes and sludges with

More information

Diaphragm seal with flange connection With internal diaphragm, threaded design Model , large working volume

Diaphragm seal with flange connection With internal diaphragm, threaded design Model , large working volume Pressure Diaphragm seal with flange connection With internal diaphragm, threaded design Model 990.41, large working volume WIKA data sheet DS 99.32 for further approvals see page 7 Applications Aggressive,

More information

ENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument

ENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument Datasheet ENGLISH Platinum Resistance Thermometer Pt100 Outdoor/Cold Store Temperature Sensors IP67 Weatherproof Housing, 4 wire single or dual element, or 4-20mA option Weatherproof IP67 rated wall mounting

More information

Process Inline Filter, Change-Over

Process Inline Filter, Change-Over Process Inline Filter, Change-Over -503-130x -520x 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL Inline filters, types PRFL and duplex inline filters are designed for process engineering and chemical plants.

More information

Liquid level switch BW 17

Liquid level switch BW 17 KROHNE 09/2001 7.02369.21.00 GR/PRINTO Liquid level switch Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level

More information

Standard features. Service intended. Design Internal diaphragm. Accuracy Refer to gauge model

Standard features. Service intended. Design Internal diaphragm. Accuracy Refer to gauge model Pressure gauge with diaphragm seal Model: P761 (Pressure gauge with inline type diaphragm seal) P762 (Pressure gauge with extension type diaphragm seal) P763 (Pressure gauge with pad type diaphragm seal)

More information

Bourdon Tube Pressure Gauges

Bourdon Tube Pressure Gauges Bourdon Tube Pressure Gauges acc. to N 87 for Industrial Applications measuring monitoring analysing Housing: 6 mm, 8 mm, 1 mm, 16 mm Rectangular asing: 96 x 96 mm, 1 x1 mm Options: mm, mm, mm, mm onnection:

More information

Resistance Temperature Detectors Mineral Insulated Thermocouples Thermoelements, Accessories and Service All-round supplier

Resistance Temperature Detectors Mineral Insulated Thermocouples Thermoelements, Accessories and Service All-round supplier Resistance Temperature Detectors Mineral Insulated Thermocouples Thermoelements, Accessories and Service All-round supplier of temperature sensors and component parts for all industrial applications Manufactured

More information

Pressure transducers DMU 02 Vario (flush)

Pressure transducers DMU 02 Vario (flush) Process engineering (flush) Ideal for hygienic processes Connection technology with numerous versions Extremely resistant to shock, pulsation and vibration Best dynamic pressure resistance at high load

More information

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma -wire: 0 0 V others on request

More information

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass flow, volume flow, temperature and density and consequently can replace different

More information

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications GE Sensing & Inspection Technologies Sentinel LNG Panametrics Ultrasonic Flowmeter for Cryogenic Liquids Benefits Improved performance, reduced maintenance and dynamic flow measurement is now available

More information

Mechatronic pressure measurement. Applications. Special features. Description

Mechatronic pressure measurement. Applications. Special features. Description Mechatronic pressure measurement Diaphragm pressure gauge with switch contacts Model 432.56, high overload safety up to 100 bar Model 432.36, safety version, high overload safety up to 400 bar WIKA data

More information

Field IT Coriolis Mass Flowmeter FCM2000

Field IT Coriolis Mass Flowmeter FCM2000 Data Sheet Field IT Coriolis Mass Flowmeter Coriolis Mass Flowmeters are used for the measurement of the mass flow and density to the highest accuracy. The fluid need not be electrically conductive. No

More information

TOPAS PMG Hydraulic sensor hot water

TOPAS PMG Hydraulic sensor hot water TOPAS PMG Hydraulic sensor hot water O f c c b a b d a d 5657244 5657264 565139.4 The hydraulic sensors form part of a heat meter and operate according to the multiple-jet measuring principle. Applications

More information

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits RHM80 High Flow Coriolis Mass Flow Meter Features Standard pressure ratings up to 341 bar (4946 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down to 0.15% Density uncertainty

More information

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma

More information

Turbine Meter. P e

Turbine Meter. P e Turbine Meter P 402.003e Turbine Flow Meters Table of Contents Applications of the Turbine Meter RQ Series Page 3 Type RQ for Liquids Page 4 RQ Turbine Meter with UST Universal Transmitter Page 7 RQ Turbine

More information

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches. PRESSURE SWITCHES 8D-LT Electro-mechanical pneumatic pressure switches 8D-LT x Electro-mechanical pneumatic pressure switches Page -0 Page -0-0 8D-LT G/, / NPT or flange Microswitch with gold plated contacts

More information

12 Temperature measurement SCT analogue

12 Temperature measurement SCT analogue 12 Temperature measurement SCT analogue Temperature measurement SCT analogue High-pressure-resistant temperature sensors For measuring temperatures up to 1,000 C Flexible operation Inline or probe-type

More information