1 SECTION LIGHTWEIGHT INSULATING CONCRETE PART 1 GENERAL 1.01 SUMMARY A. Related Sections: Cast-In-Place Concrete Steel Deck Multi-Ply Mineral Surfaced Built-Up Roofing SBS Modified Bitumen Mineral Surfaced Roofing Fully Adhered Thermoplastic Sheet roofing Flashing and Sheet Metal Drains, Floor Sinks, and Cleanouts REFERENCES AND CODES A. Florida Building Code (FBC) including FBC Test Protocols TAS 117 and TAS 105. B. Miami-Dade County Product Control. C. American Society for Testing and Materials (ASTM): 1. A653/A-96 Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip process. 2. C Test Method for Unit Weight, Yield, and Air Content (Gravimetric) of Concrete. 3. C Specification for Portland Cement. 4. C177-85(93) Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot- Plate Apparatus. 5. C332-87(91) Specification for Lightweight Aggregates for Insulating Concrete. 6. C495-91a Test Method for Compressive Strength of Lightweight Insulating Concrete. 7. C513-89(95) Test Method for Obtaining and Testing Specimens of Hardened Lightweight Insulating Concrete for Compressive Strength. 8. C Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus. Project No. SPECIFICATION GUIDELINES

2 9. C Specification for Rigid, Cellular Polystyrene Thermal Insulation. 10. C Specification for Foaming Agents Used in Making Preformed Foam for Cellular Concrete. D. Factory Mutual (FM). E. Steel Deck Institute Design Manual, latest edition. F. Underwriters Laboratories (UL) for Class A fire resistance SUBMITTALS A. Product Data: Submit for each product required and application instructions. B. Current Factory Mutual and Miami-Dade County product approvals. C. Shop Drawings: Provide roof plan showing roof slopes, thickness of insulation, roof penetrations, and specific details required for project installation. D. Submit samples of insulation board. E. Quality control submittals: 1. Laboratory results for Thermal Resistance Values based on ASTM C177 or C518. ****** ***** **** *** ** * ** *** **** ***** ****** NOTE TO SPECIFIER: Insert required FM wind uplift classification, in the following paragraph 2, as determined by ASCE 7-98 using a wind speed of 146 mph, exposure category "C", and with a wind importance factor for educational buildings of ****** ***** **** *** ** * ** *** **** ***** ****** 2. Test reports showing compliance with FM 1 - Wind Resistance Classification. 3. Current affidavit from insulating concrete manufacturer approving applicator before installation. 4. UL listing QUALITY ASSURANCE A. Comply with the Florida Building Code (FBC). B. Insulating cellular concrete shall be applied by a manufacturer's certified applicator. Project No. SPECIFICATION GUIDELINES

3 C. Any excess water on the lightweight concrete shall be removed before roof installation by vacuuming, evaporation, or other method complying with membrane manufacturers requirements. D. Applicator shall maintain a job log for submittal to A/E. The job log shall contain cast density recordings taken at a minimum interval of 1 hour. 1. Cast densities shall be measured with a calibrated scale measuring from 1 to 50 pounds in increments of 1/4 pound and be accurately calibrated to 1/16 pound. 2. The measuring bucket shall be 5 quarts or larger. 3. Measurements shall be taken according to ASTM C138. E. A "Walkability Inspection" by the A/E and the Board shall determine the lightweight insulating concrete installation as a satisfactory substrate. 1. If the installation fails the inspection, additional testing shall be required by the A/E to confirm fastener spacing or provide data for the roof system manufacturer to calculate a new fastener pattern. a. Fastener testing shall be required. b. Any areas where fasteners will not hold a minimum of 40 pounds after 5 days of cure shall be removed and recast. F. If continued noncompliance is observed and the roof deck and associated roof system cannot be corrected based on additional testing and attachment calculations, the nonconforming lightweight shall be removed and recast. G. If a denser fastener pattern is required for elevated pressure zones, a Florida registered professional engineer shall recalculate perimeter and corner spacing according to FBC Test Protocols TAS 117. H. Field withdrawal resistance testing of lightweight concrete fasteners shall be conducted according to FBC Test Protocols TAS The average withdrawal resistance values obtained in field testing shall be within 10 percent of the values listed in the Roof Assemblies Limitations. 2. If the values are not achieved, a Florida registered professional engineer can recalculate the fastener density following the procedures outlined in FBC Test Project No. SPECIFICATION GUIDELINES

4 Protocols TAS 117. I. Roofing Contractor shall consult with roofing system manufacturer for compatibility with all surface coatings or treatments. J. Direct-adhered single ply systems shall be installed in strict compliance with manufacturer's specifications and the Miami-Dade County Product Control Notice of Acceptance. K. Installation of this decking component and diaphragm load requirements shall be in strict compliance with application requirements set forth in Chapters 19 and 22 of the Florida Building Code (FBC). L. All coatings or surface preparation materials applied to the lightweight concrete shall be listed as an approved interface material with the roof membrane manufacturer. M. Topping applied over insulation boards and any decking/substrate that allows deflection under normal traffic shall be installed within 4 hours of board installation. 1. If installation is interrupted due to inclement weather or other situations beyond the control of the contractor, the installed insulation board shall be inspected to confirm adhesion to the substrate. 2. Over solid substrates, topping installation shall not be delayed over 24 hours. N. Roof Membrane Application: Contractor shall coordinate commencement of roofing over the lightweight insulating concrete after satisfactorily passing Florida Building Code TAS 105 fastener pullout test. O. Conduct pre-roofing conference before the installation of the roof insulation with A/E and representatives from manufacturer of insulating concrete, roofing membrane materials, and all other related trades in attendance. At the meeting date determined, by mutual agreement, between parties concerned. P. Oven-Dry Density: Determine according to Section 7 of Test for Compressive Strength of Lightweight Insulating Concrete, ASTM C495. Q. Compressive Strength: Determine compressive strength according to requirements of ASTM C495. Project No. SPECIFICATION GUIDELINES

5 1.05 DELIVERY AND STORAGE A. Deliver material in manufacturer's original undamaged packages or acceptable bulk containers. B. Store packaged material to protect them from the elements or physical damage. C. Do not use cement that shows indications of moisture damage, caking, or other signs of deterioration WARRANTY A. Warrant to the Board that for 10 years from the date of the completion of the lightweight insulating concrete that: 1. The roof insulation system shall remain in a reroofable condition should the roof membrane require replacement. 2. The actual resistance to heat flow through the roof insulation system shall be at least 80 percent of design thermal resistance. 3. The roof insulation will remain in place even if the roof membrane sustains wind damage. PART 2 PRODUCTS 2.01 MANUFACTURERS A. Insulating Concrete: 1. Concrecel by Concrecel International. 2. Cellular Hybrid by Elastizell. 3. NVS (Non-Vented Substrate) by Siplast. 4. Zonocel by Siplast. 5. Insulcel by Siplast MATERIALS A. Insulating Concrete Physical Properties: 1. Portland cement and pregenerated foam with water: a. Wet density at point of placement: pcf. b. Minimum oven dry density: pcf. c. Minimum compressive strength: 300 psi. 2. Portland cement and vermiculite concrete with water(1:3.5): Project No. SPECIFICATION GUIDELINES

6 a. Wet density at point of placement: pcf. b. Minimum oven dry density: 35 pcf. c. Minimum compressive strength: 300 psi. B. Insulation Board: One pound density expanded polystyrene board with 25 to 35 bonding and venting slots. Deliver each bundle of 2 foot by 4 foot boards to the job site with clear identification as to the manufacturer and shall carry the FM approval label on each bundle. C. Portland Cement shall comply with ASTM C150, Type I, II, or III. D. Water: Potable, clean, maximum chloride level of 250 ppm, and free from deleterious amount of acid, alkali, and organic material. E. Foaming agent: Liquid concentrate shall be manufactured and be delivered to the job site with clear identification as to manufacturer and type of material according to ASTM C869. F. Admixtures shall not be used unless specifically recommended by the manufacturer. ****** ***** **** *** ** * ** *** **** ***** ****** NOTES TO SPECIFIER: Reinforcing mesh may be required in some fire rated assemblies. ****** ***** **** *** ** * ** *** **** ***** ****** G. Mesh Reinforcement: Keydeck style galvanized mesh or equal. PART 3 EXECUTION 3.01 EXAMINATION A. Surfaces to receive insulating concrete shall be sound, free of loose material, and free from defects affecting application. B. Installation of other work passing through fill or concealed shall be complete and accepted before starting the work. C. The applicator shall be responsible for inspection and approval of the substrate as suitable for roof insulation. D. Installation of curbs, equipment supports, roof drains, Project No. SPECIFICATION GUIDELINES

7 framing for openings, and wood nailers shall be in place before application of material. E. Poured Surface Finish: 1. Surface shall be bonded firmly and free from loose materials. 2. Screeded finish of surface shall be free from extreme roughness capable of interfering with proper bonding of roofing membrane and free from shrinkage and cracks. 3. Surface Dryness: Exposed surface shall look and feel substantially dry, and shall have a uniformly gray cement color INSTALLATION A. Slurry: Cover substrate with a 1/8" slurry coat of the lightweight insulating fill. B. Insulation Board: 1. Place insulation board in the 1/8" slurry coat. 2. Insulation board placement shall be made within 30 minutes of slurry coat placement. 3. Place insulation board in a manner that provides full contact of slurry to board. 4. Lay insulation board in brick paver pattern with joints staggered and side and end joints butted snugly. 5. Under no circumstances shall insulation board be laid dry on substrate. 6. Remove loose boards and immediately re-grout. C. Lightweight Insulating Fill: 1. Within 24 hours of insulation board placement, place a minimum of 2 inches of lightweight insulating fill over the insulation board and screed to an even surface to receive the roofing membrane. 2. Increase thickness as required at 1/4" per foot slope to obtain roof drainage slopes as indicated on Drawings. 3. Roof Crickets: At roof low points between roof drains, between roof drains and parapets and at high side of fan curbs, provide insulation concrete crickets uniformly sloped not less than 1/2" per foot. D. Installed system shall achieve a minimum average R-value of Project No. SPECIFICATION GUIDELINES

8 QUALITY CONTROL A. Check the cast density according to ASTM C869 hourly at the point of placement. B. Testing: Make set of 4 standard cylinders of each day's mix and text according to ASTM C495. When more than 75 cubic yards of concrete are poured in 1 day, make a set of specimens of each 75 yards. C. Drainage Test: After initial set, provide hose test to assure proper drainage slopes with no ponding PROTECTION A. Do not expose insulating concrete to prolonged exposure to the elements more than 7 days. B. Do not use as a temporary working surface without adequate surface protection, nor allow it to function as a temporary dry in. C. Prevent traffic on roof deck until applicator allows such traffic. END OF SECTION Project No. SPECIFICATION GUIDELINES

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500 07503 ROOF ASSEMBLY LIGHTWEIGHT INSULATING CONCRETE (LWIC) ************************************************************************************************************* SPECIFIER: All roof-related items

More information

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500 07503 ROOF ASSEMBLY LIGHTWEIGHT INSULATING CONCRETE SPECIFIER: All roof-related items above or outside the structural roof deck, including such work as blocking, insulation, membrane, sheet metal, hatches,

More information

Lightweight Insulating Concrete Roof Decks

Lightweight Insulating Concrete Roof Decks MeARlCrEte Tm Lightweight Insulating Concrete Roof Decks WWW.AErIXINDUsTrIEs.COm M EARLCRETETM lightweight insulating concrete is produced on the job site by mixing Portland cement -water slurry with the

More information

CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES

CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES PART 1: SCOPE CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES 1.1 An Approved Celcore Applicator shall furnish all labor, materials and supervision

More information

Lightweight Insulating Concrete Systems

Lightweight Insulating Concrete Systems Lightweight Insulating Concrete Systems A sustainable, high performance roof insulation solution. A Siplast Lightweight Insulating Concrete System and Paradiene 20/30 FR Roof System were installed on this

More information

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 075423 - THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including Division 00 Bidding Requirements and other Division

More information

SECTION CLAY BARREL TILE ROOFING. A. American Society for Testing and Materials (ASTM):

SECTION CLAY BARREL TILE ROOFING. A. American Society for Testing and Materials (ASTM): SECTION 07320 CLAY BARREL TILE ROOFING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 02072 - Removals. 2. 07600 - Flashing and Sheet Metal. 1.02 REFERENCES A. American Society for Testing and Materials

More information

SPECIFICATION GUIDELINE

SPECIFICATION GUIDELINE Environmental StoneWorks specification guideline should be used to assist design professionals in the preparation of projects. Edit and delete items that may not be applicable. Verify all referenced section

More information

SPECIFICATION GUIDELINE

SPECIFICATION GUIDELINE SPECIFICATION GUIDELINE Environmental Stoneworks Corporate Office 6300 East Stapleton Drive South Denver, CO 80216 Phone (303) 309-3040 Fax (303) 309-3059 www.estoneworks.com Environmental Stoneworks specification

More information

ACFoam-II HCFC Free "Green" Polyiso Specification

ACFoam-II HCFC Free Green Polyiso Specification ACFoam-II HCFC Free "Green" Polyiso Specification To help owners and specifiers, the following specification strategies are offered as they relate to product performance when including HCFC FREE Green

More information

A. National Roofing Contractors Association (NRCA) Roofing and Waterproofing Manual

A. National Roofing Contractors Association (NRCA) Roofing and Waterproofing Manual SECTION 07 22 16 - ROOF AND DECK INSULATION Specifier Note: There are numerous types of roof insulation, some which are installed in multiple-layer roof assemblies. Specifier to verify Project requirements

More information

SECTION CLAY BARREL TILE ROOFING Removals Flashing and Sheet Metal.

SECTION CLAY BARREL TILE ROOFING Removals Flashing and Sheet Metal. SECTION 07320 CLAY BARREL TILE ROOFING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 02072 - Removals. 2. 07600 - Flashing and Sheet Metal. 1.02 REFERENCES A. American Society for Testing and Materials

More information

Firestone Polyiso Boards

Firestone Polyiso Boards Firestone Polyiso Boards Superior energy efficiency. Superior protection. Firestone Polyiso Boards POLISOBROUK10.indd 1 1/04/10 14:26 Firestone Polyiso Boards Firestone total roofing systems Since Firestone

More information

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO SECTION 07220 - ROOF INSULATION PART 1 - GENERAL 1.01 DESCRIPTION A. Work included: The Roofing Contractor will provide all polyisocyanurate insulation and high density wood fiber roof insulation (tapered

More information

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein. SECTION 10530 - EXTRUDED ALUMINUM WALKWAY COVERS PART I - GENERAL.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General, Supplementary, and Special Conditions and Division

More information

ROOFING APPLICATION STANDARD (RAS) No. 109

ROOFING APPLICATION STANDARD (RAS) No. 109 ROOFING APPLICATION STANDARD (RAS) No. 109 Scope 1.1 This Roofing Application Standard sets the requirements to determine whether a substrate and surrounding environmental conditions are appropriate for

More information

SECTION PREPARATION FOR RE-ROOFING

SECTION PREPARATION FOR RE-ROOFING SECTION 07 01 50.19 PREPARATION FOR RE-ROOFING SPEC WRITER NOTES: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Edit Summary article below after establishing

More information

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

Stonecraft Industies 8300 County Road Holmesville, OH

Stonecraft Industies 8300 County Road Holmesville, OH Stonecraft Industies 8300 County Road Holmesville, OH Tel: (888) 580-6448 e-mail: customercare@stonecraft.com website: www.stonecraft.com SECTION 04 73 00 MANUFACTURED MASONRY VENEER GENERAL NOTES TO SPECIFIER:

More information

SECTION GYPSUM CEMENT UNDERLAYMENT RECOMMENDED SPECIFICATION FOR DURA-CAP FLOOR UNDERLAYMENT OVER EXTRUDED OR EXPANDED POLYSTYRENE FOAM

SECTION GYPSUM CEMENT UNDERLAYMENT RECOMMENDED SPECIFICATION FOR DURA-CAP FLOOR UNDERLAYMENT OVER EXTRUDED OR EXPANDED POLYSTYRENE FOAM SECTION 03 54 00 1 GYPSUM CEMENT UNDERLAYMENT RECOMMENDED SPECIFICATION FOR DURA-CAP FLOOR UNDERLAYMENT OVER EXTRUDED OR EXPANDED POLYSTYRENE FOAM PART 1 GENERAL 1.01 SUMMARY A. This is the recommended

More information

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof SECTION 07550 MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof This section is based on the products of MFM Building Products Corp., which is located at: 525 Orange St. P. O. Box 340 Coshocton, OH 43812

More information

MANUFACTURER S SPECIFICATION

MANUFACTURER S SPECIFICATION MANUFACTURER S SPECIFICATION Eldorado Stone Corporation PO Box 489 Carnation, WA 98014 Tel: (800) 925-1491 Fax: (425) 333-4755 e-mail: general@eldoradostone.com website: www.eldoradostone.com SECTION 04730

More information

SECTION ELASTOMERIC MEMBRANE ROOFING

SECTION ELASTOMERIC MEMBRANE ROOFING SECTION 07 5300 - PART 1 GENERAL 1.01 SECTION INCLUDES A. Elastomeric roofing membrane, mechanically fastened conventional application. B. Insulation, flat and tapered. C. Flashings. D. Roofing cant strips,

More information

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1 Louis Armstrong New Orleans International Airport NOAB Project # 8910-01233 PART 1 - GENERAL SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

SECTION 07530CP EPDM MEMBRANE ROOFING

SECTION 07530CP EPDM MEMBRANE ROOFING PART 1 GENERAL 1.1 SUMMARY SECTION 07530CP EPDM MEMBRANE ROOFING A. Section includes: 1. Adhered membrane roofing and flashing 2. Mechanically fastened roof insulation 3. Walkway pads 1.2 ARCHITECTURAL

More information

1. Clean the existing totally adhered or mechanically attached roof membrane: TPO, EPDM, Hyplon,

1. Clean the existing totally adhered or mechanically attached roof membrane: TPO, EPDM, Hyplon, Summary Specification Re-Skinning Over Two Existing Roofs The Top Roof Being a Totally Adhered Single Ply Over a Built-Up-Roof On A Poured-in-Place Concrete Deck Using the Existing Angle Change Terminations

More information

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS SECTION 075216 - PART 1 - GENERAL 1.1 SUMMARY A. Section includes styrene-butadiene-styrene (SBS) modified bituminous membrane roofing. 1.2 DEFINITIONS A. Hot Roofing Asphalt: Roofing asphalt heated to

More information

SECTION STEEL DECKING

SECTION STEEL DECKING SECTION 05 31 00 STEEL DECKING SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Refer to Section 05 36 00, COMPOSITE METAL DECKING for floor

More information

SECTION MANUFACTURED MASONRY VENEER

SECTION MANUFACTURED MASONRY VENEER TM Dutch Quality Stone 18012 Dover Road Mt. Eaton, OH 44659 Tel: (330) 359-7866 Fax: (330) 359-5990 e-mail: info@dutchqualitystone.com website: www.dutchqualitystone.com SECTION 04 73 00 MANUFACTURED MASONRY

More information

Understanding Wind Uplift Ratings

Understanding Wind Uplift Ratings Page 1 of 5 Home Understanding Wind Uplift Ratings By Stan Choiniere September 1, 2006 What is an FM Approvals wind test, and what do the various wind uplift ratings mean? This question is frequently asked,

More information

SECTION ROOF ACCESSORIES

SECTION ROOF ACCESSORIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 72 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers. SECTION 05 31 33 - STEEL FORM DECKING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the contract, including General and Supplementary Conditions and Division 01 - Specification

More information

GE SCM3500 High Solids Silicone Roof Coating

GE SCM3500 High Solids Silicone Roof Coating GE SCM3500 High Solids Silicone Roof Coating Installation Guide Specification For GRANULATED or SMOOTH MODIFIED BITUMEN / BUR (20 Year Warranty) Warranty PART 1 GENERAL 1.01 SUMMARY A. This specification

More information

Recommended Fastening Patterns for Rmax Insulation in Low Slope Roofing Applications

Recommended Fastening Patterns for Rmax Insulation in Low Slope Roofing Applications Recommended Fastening Patterns for Rmax Insulation in Low Slope Roofing Applications INTRODUCTION Rmax recommends that any insulation which is laid over a steel or wood roof deck be attached with mechanical

More information

B. Coordinate all Roof Assembly components with work before and after. See especially:

B. Coordinate all Roof Assembly components with work before and after. See especially: 07500 ROOF ASSEMBLY ************************************************************************************************************* SPECIFIER: All roof-related items above or outside the structural roof

More information

SECTION RIGID PAVEMENT. 1. Portland Cement Concrete (PCC) pavement. 2. Section Aggregate Base Course.

SECTION RIGID PAVEMENT. 1. Portland Cement Concrete (PCC) pavement. 2. Section Aggregate Base Course. SECTION 02750 RIGID PAVEMENT PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Portland Cement Concrete (PCC) pavement. B. Related Sections: 1.2 REFERENCES 1. Section 02315 Excavation. 2. Section 02721

More information

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500 07721 ROOF ASSEMBLY SUPPORTS FOR ROOFTOP EQUIPMENT ****************************************** SPECIFIER: All roof-related items above or outside the structural roof deck, including such work as blocking,

More information

Sept 30, 2004 Page 1

Sept 30, 2004 Page 1 Sept 30, 2004 Page 1 This section includes a manufacturer's guide specification for TERRAFOAM EPS building insulation. Refer also to Product Description for detailed product properties, options, and other

More information

PRODUCT CONTROL SECTION

PRODUCT CONTROL SECTION MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590

More information

SECTION ROOF PEDESTAL PAVER SYSTEM

SECTION ROOF PEDESTAL PAVER SYSTEM SECTION 07 76 00 ROOF PEDESTAL PAVER SYSTEM ************************************************************************************************************************ Edit entire master to suit project requirements.

More information

DIVISION 3 HEAVY DUTY CONCRETE FLOOR TOPPING SECTION 03340

DIVISION 3 HEAVY DUTY CONCRETE FLOOR TOPPING SECTION 03340 DIVISION 3 HEAVY DUTY CONCRETE FLOOR TOPPING SECTION 03340 PART 1 - GENERAL 1.01 GENERAL REQUIREMENTS A. The General provisions of the contract, including GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS AND

More information

ROXUL Roof and Deck Insulation Section Master Guide Specification (MONOBOARD ) Page 1 April 2016

ROXUL Roof and Deck Insulation Section Master Guide Specification (MONOBOARD ) Page 1 April 2016 Master Guide Specification (MONOBOARD ) Page 1 Click on the pilcrow in the MS Word Toolbar to toggle ROXUL GUIDE NOTES on and off. Delete this text before incorporating the section into a Project Manual.

More information

ROXUL Roof and Deck Insulation Section Master Guide Specification Page 1 April 2016

ROXUL Roof and Deck Insulation Section Master Guide Specification Page 1 April 2016 Master Guide Specification Page 1 Click on the pilcrow in the MS Word Toolbar to toggle ROXUL GUIDE NOTES on and off. Delete this text before incorporating the section into a Project Manual. 1 GENERAL

More information

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM SECTION 13 34 21 - STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM PART 1 - GENERAL 1.1 DESCRIPTION A. The structural retrofit roof sub-framing system will provide support for a new metal roofing system constructed

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING (TO RESTORE EPDM MEMBRANES) PART 1 GENERAL 1.01 DESCRIPTION A. The scope of this design guideline is to describe the installation of the ALDOCOAT Silicone reflective

More information

COMMERCIAL BUILDING APPLICATIONS

COMMERCIAL BUILDING APPLICATIONS EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that

More information

1 Firestone EPDM Roofing Systems

1 Firestone EPDM Roofing Systems 1 Firestone 1. Firestone EPDM Systems To ensure a long-lasting, trouble-free roof today, it is not sufficient to manufacture high quality roofing membranes. Experience learned that roofing membranes need

More information

***************************************************************************************************************

*************************************************************************************************************** 03450 ARCHITECTURAL PRECAST CONCRETE *************************************************************************************************************** SPECIFIER: CSI MasterFormat 2004 number 03 45 13 ***************************************************************************************************************

More information

SECTION G RELIEF VENTS A-0

SECTION G RELIEF VENTS A-0 SECTION G A-0 TABLE OF CONTENTS Thaler Or Equal RV-1A/-RV-1C Relief Vent RV-2A/-RV-2C Relief Vent RV-3A/-RV-3C One Way Relief Vent Relief Vent Specification G-0 G-1 G-2 G-3 G-4, G-5, G-6 WHAT IT TAKES

More information

Exterior Research & Design, L.L.C. Building Science and Envelope Consultants

Exterior Research & Design, L.L.C. Building Science and Envelope Consultants Exterior Research &, L.L.C. Building Science and Envelope Consultants Certificate of Authorization #9503 Evaluation Report 00256.09.06 Evaluation of Roofing s for Florida Product Approval #FL7508 Prepared

More information

Section Pre-Applied Sheet Membrane Waterproofing

Section Pre-Applied Sheet Membrane Waterproofing Section 071324 Pre-Applied Sheet Membrane Waterproofing PART 1 GENERAL 1.01 SUMMARY A. The Work of this Section includes, but is not limited to, pre-applied sheet membrane waterproofing that forms an integral

More information

FOAMULAR Commercial Roofing

FOAMULAR Commercial Roofing Low Slope Insulated Roof Systems Roofing Systems Single-ply roofing s are flexible sheets of compounded synthetic materials that are manufactured in a factory. Single ply roof systems provide strength,

More information

FIVE STAR PRODUCTS, INC. (800)

FIVE STAR PRODUCTS, INC.  (800) FIVE STAR PRODUCTS, INC. www.fivestarproducts.com (800) 243-2206 1 of 12 DESIGN-A-SPEC GUIDELINES FIVE STAR STRUCTURAL CONCRETE V/O CONTENTS PART A - GENERAL CONDITIONS PART B - MATERIAL SPECIFICATIONS

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 07 40 00 Roofing 1. General Several factors repeatedly show up during the inspection of roofs that have failed prematurely. They include inappropriate use of materials, poor drainage systems, poor details

More information

ROOF ASSEMBLIES CHAPTER 9

ROOF ASSEMBLIES CHAPTER 9 CHAPTER 9 ROOF ASSEMBLIES SECTION R901 GENERAL R901.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. SECTION R902 ROOF CLASSIFICATION

More information

Exterior Research & Design, L.L.C. Building Science and Envelope Consultants

Exterior Research & Design, L.L.C. Building Science and Envelope Consultants Exterior Research & Design, L.L.C. Building Science and Envelope Consultants Certificate of Evaluation Report 3520.03.04-R2 Evaluation of Roof s for Florida Product Approval #FL2533-R2 Prepared for: CertainTeed

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3916 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 07 00

More information

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING SECTION 07 13 52 MODIFIED BITUMINOUS SHEET WATERPROOFING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC. 0 Most Widely Accepted and Trusted ICC ES Legacy Report ICC ES 000 (800) 42 6587 (562) 699 054 www.icc es.org ER 520 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 07 00 00 THERMAL

More information

SECTION CONCRETE. B. ACI 318 Building Code Requirements for Structural Concrete and Commentary

SECTION CONCRETE. B. ACI 318 Building Code Requirements for Structural Concrete and Commentary SECTION 03300 CONCRETE PART 1 GENERAL 1.01 SCOPE OF WORK Concrete foundation walls, sanitary structures, pipe encasements, thrust blocking and slabs on grade. 1.02 REFERENCES A. ACI 301 Specification for

More information

Product Guide Specification

Product Guide Specification SofSURFACES, Inc. 4393 Discovery Line PO Box 239 Petrolia, Ontario N0N 1R0 Canada Toll Free (800) 263-2363 Phone (519) 882-8799 Fax (519) 882-2697 Website www.sofsurfaces.com E-mail alltinfo@sofsurfaces.com

More information

Lightweight insulating concrete (LWIC) is one of the most

Lightweight insulating concrete (LWIC) is one of the most Lightweight insulating concrete (LWIC) is one of the most efficient, accommodating roof deck systems available. Its versatility allows for a fast and easy solution for custom drainage designs, working

More information

SECTION PRECAST CONCRETE PAVERS AND PEDESTAL LOK DOWN SYSTEM

SECTION PRECAST CONCRETE PAVERS AND PEDESTAL LOK DOWN SYSTEM SECTION 07555 PRECAST CONCRETE PAVERS AND PEDESTAL LOK DOWN SYSTEM PART ONE: GENERAL 1.1 SUMMARY A. Concrete paver and pedestal support system with Lok Down devices are to be placed over roofing/waterproofing

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 6587 (562) 699 0543 www.icc es.org ESR 3152 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

Corium Brick Rainscreen System Specifications

Corium Brick Rainscreen System Specifications CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated

More information

CS-100 Guide Specifications

CS-100 Guide Specifications MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification

More information

Madewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770)

Madewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770) Madewell Products Corporation December 2014 7561 Industrial Court Alpharetta, GA 30004 Office: (770) 475-8199 Fax: (770) 475-8167 Product Guide Specification SECTION 03935 RESTORATION MORTAR AND EPOXY

More information

UL Evaluation Report UL ER Issued: July 25, UL Category Code: ULFB. CSI MasterFormat

UL Evaluation Report UL ER Issued: July 25, UL Category Code: ULFB. CSI MasterFormat UL Evaluation Report UL ER10167-01 Issued: July 25, 2014 Visit UL s On-Line Certifications Directory: www.ul.com/erdirectory for current status of Report. UL Category Code: ULFB CSI MasterFormat DIVISION:

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3392 Reissued 06/2017 This report is subject to renewal 06/2018. DIVISION: 07 00

More information

FIVE STAR PRODUCTS, INC. (800)

FIVE STAR PRODUCTS, INC.  (800) FIVE STAR PRODUCTS, INC. www.fivestarproducts.com (800) 243-2206 Page 1 of 11 DESIGN-A-SPEC GUIDELINES FIVE STAR RS ANCHOR GEL CONTENTS PART A - GENERAL CONDITIONS PART B - MATERIAL SPECIFICATIONS PART

More information

SECTION Specification for Building Limes Specification For Building Sands from Natural Sources Methods of Tests for Paints.

SECTION Specification for Building Limes Specification For Building Sands from Natural Sources Methods of Tests for Paints. SECTION 09200 PART 1 - GENERAL 1.01 DESCRIPTION A. Extent of Work: The extent of lath and plaster work is shown on the drawings and in schedules and includes interior and exterior plaster work, and fibreglass

More information

(Project Location) (your firm's name)

(Project Location) (your firm's name) SECTION 07 21 00 THERMAL INSULATION PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including the Conditions of the Contract and Division 01 Specification Sections

More information

THE SITUATION WITH STEEL DECKS

THE SITUATION WITH STEEL DECKS THE SITUATION WITH STEEL DECKS Steel roof deck design can affect roof system selection and design by Mark S. Graham 32 www.professionalroofing.net MARCH 2017 teel roof decks commonly are encountered in

More information

TECHNICAL SPECIAL PROVISION FOR CONCRETE REPAIRS. Financial Project ID , &

TECHNICAL SPECIAL PROVISION FOR CONCRETE REPAIRS. Financial Project ID , & TECHNICAL SPECIAL PROVISION FOR CONCRETE REPAIRS Financial Project ID 429140-1-52-01, 429140-2-52-01 & 428267-1-52-01 The official record of this Technical Special Provision is the electronic file signed

More information

SECTION PRECAST STRUCTURAL PRETENSIONED CONCRETE

SECTION PRECAST STRUCTURAL PRETENSIONED CONCRETE PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 03 41 33 PRECAST STRUCTURAL PRETENSIONED CONCRETE SPEC WRITER NOTE: Delete between //--// if not applicable to project. Also delete any other item or paragraph

More information

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers. SECTION 05 31 13 STEEL FLOOR DECKING PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including General and Supplementary Conditions and Division 01 - Specification

More information

Alply CLASSIC WALL Architectural Insulated Panel Wall System

Alply CLASSIC WALL Architectural Insulated Panel Wall System SECTION 07 42 13 INSULATED METAL WALL PANELS ALPLY Insulated Panels Alply CLASSIC WALL Architectural Insulated Panel Wall System PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Smooth, non-embossed steel, insulated

More information

ULTRA-HIGH STRENGTH SHEAR KEY GROUT

ULTRA-HIGH STRENGTH SHEAR KEY GROUT ULTRA-HIGH STRENGTH SHEAR KEY GROUT 187 April 30, 2015 SPECIFICATION FOR ULTRA-HIGH STRENGTH SHEAR KEY GROUT SCOPE This specification consists of the proper material selection and production of Ultra-High-

More information

SECTION CAST IN PLACE CONCRETE FOR FLOOR SLABS ON GRADE THAT WILL RECEIVE SEMI-PERMEABLE OR IMPERMEABLE FLOOR FINISHES

SECTION CAST IN PLACE CONCRETE FOR FLOOR SLABS ON GRADE THAT WILL RECEIVE SEMI-PERMEABLE OR IMPERMEABLE FLOOR FINISHES GUIDE SPECIFICATION SECTION CAST IN PLACE CONCRETE FOR FLOOR SLABS ON GRADE THAT WILL RECEIVE SEMI-PERMEABLE OR IMPERMEABLE FLOOR FINISHES PART 1 - SCOPE 1.01 WORK INCLUDED: 1.1.1 This guide covers the

More information

ITEM NO SLIPLINING GROUT

ITEM NO SLIPLINING GROUT 1101.1 DESCRIPTION ITEM NO. 1101 SLIPLINING GROUT Place grout in the annular space between the sliplining pipe and the host sewer. Completely fill the annular space without deflecting the pipe. Test grout

More information

PRODUCT GUIDE SPECIFICATION

PRODUCT GUIDE SPECIFICATION PRODUCT GUIDE SPECIFICATION Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat,

More information

MASTER GUIDE SPECIFICATION

MASTER GUIDE SPECIFICATION TOTALJOIST (TJ) GUIDE NOTE: This master specification section includes TOTALJOIST GUIDE NOTEs identified as TJ GUIDE NOTE for information purposes and to assist the specification writer in making appropriate

More information

SECTION CONTROLLED LOW STRENGTH MATERIAL

SECTION CONTROLLED LOW STRENGTH MATERIAL SECTION 03300 CONTROLLED LOW STRENGTH MATERIAL PART 1 GENERAL 1.1 DESCRIPTION A. This Section specifies Controlled Low Strength Material (CLSM) to be used as described in this specification, including

More information

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017 SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE Amended 28 August 2017 BRANZ Appraisals Technical Assessments of products for building and construction. Sika (NZ) Ltd PO Box 19 192 Avondale Auckland 1746

More information

Narrow Modular Pavers (NMP) for Sand-Set Installations

Narrow Modular Pavers (NMP) for Sand-Set Installations The following specification refers to the Stepstone, Inc. product known as: Narrow Modular Pavers (NMP) for Sand-Set Installations Narrow Modular Pavers are part of the California Architectural Paver line

More information

SECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system.

SECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system. PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Fusion welded and rackable ornamental steel picket fence system. B. Related sections: 1. Section 03310 Concrete Work for post support. 2. Section 09960

More information

ROOF BALLAST MATERIALS ARCHITECTURAL CONCRETE PAVING SLABS SRS LEVELING BLOCK SYSTEM INSTALLATION PART GENERAL 1.

ROOF BALLAST MATERIALS ARCHITECTURAL CONCRETE PAVING SLABS SRS LEVELING BLOCK SYSTEM INSTALLATION PART GENERAL 1. 07555 - ROOF BALLAST MATERIALS ARCHITECTURAL CONCRETE PAVING SLABS SRS LEVELING BLOCK SYSTEM INSTALLATION PART 1.00 - GENERAL 1.01 SUMMARY: A. The work of this section consists of furnishing and installing

More information

SAM HOUSTON STATE UNIVERSITY DIVISION 07 THERMAL & MOISTURE PROTECTION SECTION ROOFING SYSTEMS DESIGN AND CONSTRUCTION STANDARDS February 2016

SAM HOUSTON STATE UNIVERSITY DIVISION 07 THERMAL & MOISTURE PROTECTION SECTION ROOFING SYSTEMS DESIGN AND CONSTRUCTION STANDARDS February 2016 PART 1: GENERAL 1.01 Scope Of Standard 1.02 Reference Standards 1.03 Quality Control A. This standard provides general guidance concerning the specific preferences of the Sam Houston State University for

More information

SECTION METAL ROOF PANELS

SECTION METAL ROOF PANELS SECTION 07 41 13 PART 1 GENERAL 1.1 SECTION INCLUDES A. Standing-seam roof panels. B. Metal roofing accessories. 1.2 RELATED SECTIONS A. Section 07 62 00 - Sheet Metal Flashing. B. Section 07 72 00 - Roof

More information

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012) Gaines Charter Township 8555 Kalamazoo Ave SE Caledonia MI 49316 PH: 616 698-6640 Fax: 616 698-2490 www.gainestownship.org Building Department Statement of Special Inspections Michigan Building Code 2012

More information

September 1, 2003 CONCRETE MANUAL SPECIAL TYPES OF CONCRETE

September 1, 2003 CONCRETE MANUAL SPECIAL TYPES OF CONCRETE September 1, 2003 CONCRETE MANUAL 5-694.800 5-694.810 GENERAL SPECIAL TYPES OF CONCRETE 5-694.800 In the general use of the word concrete, the idea implied is the conventional placement of the material

More information

02800 SHADE STRUCTURES

02800 SHADE STRUCTURES 02800 SHADE STRUCTURES for PLAY AREAS ****************************************** SPECIFIER: The shade structure shall utilize a four point hypar system with four columns located a minimum of 10 feet from

More information

PRODUCT CONTROL SECTION

PRODUCT CONTROL SECTION MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings. SECTION 03 54 16 - HYDRAULIC CEMENT UNDERLAYMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM ARCHITECTURAL SPECIFICATIONS MANUFACTURER: InterBlock LLC PO Box 1123, Sheboygan, WI 53082 Phone Number 920-207-7234 SECTION 03100 STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM PART 1 GENERAL 1.01 Summary

More information

SECTION HVAC GRAVITY VENTILATORS

SECTION HVAC GRAVITY VENTILATORS SECTION 23 37 23 HVAC GRAVITY VENTILATORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

A. Drawings and general provisions of the contract, including General and Supplementary Conditions, apply to this section.

A. Drawings and general provisions of the contract, including General and Supplementary Conditions, apply to this section. SECTION 03 01 30 MAINTENANCE OF CAST-IN-PLACE CONCRETE SECTION 03 01 40 MAINTENANCE OF PRECAST CONCRETE SECTION 03 01 50 MAINTENANCE OF CAST DECKS AND UNDERLAYMENT SECTION 03 01 60 MAINTENANCE OF GROUTING

More information