Adhered Roofing Systems with Aqua Base 120 Bonding Adhesive. UL/FM Code Approval Guide Table of Contents February 2012
|
|
- Dustin Horn
- 5 years ago
- Views:
Transcription
1 Adhered Roofing Systems with Aqua Base 120 Bonding Adhesive UL/FM Code Approval Guide Table of Contents February 2012 UNDERWRITERS LABORATORIES (UL) APPROVAL UL Class A... 1 UL Class B... 2 FACTORY MUTUAL (FM) APPROVALS FM Class 1A-90 - Mechanically Attached... 3 FM Class 1A Mechanically Attached... 4 FM Class 1A-945 Direct Application or Polyisocyanurate Attached With DASH/FAST Adhesive to Structural Concrete... 5 FM Class 1A-915 Dens-Deck or Dens-Deck Prime or OSB Attached with DASH/FAST Adhesive to Structural Concrete... 5 FM Class 1A-660 Versico Recovery Board over Polyiso attached with DASH/FAST Adhesive to Structural Concrete... 5 FM Class 1A-645- Versico Recovery Board or Dens-Deck Prime over EPS attached with DASH/FAST Adhesive to Structural Concrete... 5 FM Class 1A-375- OSB/Polyiso Composite and Membrane Attached with DASH/FAST Adhesive to Structural Concrete... 5 FM Class 1A-150 with DASH/FAST Adhesive to Oriented Strand Board (OSB)... 6 FM Class 1A-90 Attachment to Gypsum with FAST 100-LV Adhesive... 6 FM Class 1A-90 - Base Layer of Fastened; Top Layer of Adhered With DASH/FAST Adhesive... 7 FM Class 1A-240 over Tectum... 8 Existing FM Rating Retained - Adhering to Existing Roof With DASH/FAST Adhesive... 9 FM Class 1A Utilizing Versico 725 Vapor Retarder (Steel Decks) FM Class 1A-660, 1A-915 and 1A Utilizing Versico 725 Vapor Retarder and Secured With DASH/FAST Adhesive (Structural Concrete Decks) FM Class 1A-90 and 1A attached with hot asphalt FM Class 1A-300 and 1A attachment to concrete with OlyBond 500 BA Adhesive FM Class 1A attachment to concrete with OlyBond500 BA Adhesive FM Class 1A-90 - attachment to Tectum with OlyBond500 BA Adhesive FM Class 1A-90 - Base Layer of Fastened; Top Layer of Adhered With OlyBond500 BA Adhesive Page
2 Underwriter Laboratories VersiFleece Adhered Roofing Systems with VersiFleece TPO 100 or 115 Membrane (white, tan or gray) UL Class A * Non-Combustible and Combustible (For combustible decks, gypsum wallboard must be installed beneath the insulation listed) (4) (1)(2) (UL Classified) Thickness Versico Recovery Board (3) 1/2-3 Versico Recovery Board(3)/ Polyisocyanurate Versico Recovery Board(3)/Polystyrene ** Versico Polyisocyanurate MP-H, SecurShield 1/2 Min./Any 1/2 Min./Any 1 Any 1/2 Combustible Dens-Deck Prime 1/4 Min. Dens-Deck Prime/Polyisocyanurate Dens-Deck Prime/ Polystyrene 1/4 Min/Any Versico SecurShield Polyisocyanurate (5) Min. 3 1/2" Versico SecurShield CD (5) Min 1" * As an option to adhering the VersiFleece Membrane with Aqua Base 120 Bonding Adhesive, the membrane can be loose-laid and mechanically fastened to the roof deck in accordance with Versico s VersiFleece Specification. ** Assembly not permitted on combustible decks, even with gypsum board underneath. Dens-Deck Prime must be installed over polystyrene as identified in combustible deck listing. (1) When multiple insulation layers are listed (i.e. Versico Recovery Board/Polyisocyanurate), the insulation listed first (Versico Recovery Board) is directly under the membrane. (2) may be mechanically fastened or attached with DASH/FAST Adhesive, OlyBond500 BA or hot asphalt. (3) 7/16 inch thick non-veneer, APA rated oriented strand board (OSB) may be substituted for Versico Recovery Board in all listed assemblies. The fastening pattern for the OSB must conform with Versico Detail FB-27-C (when mechanically fastened). (4) Minimum 1/2 thick gypsum wallboard can be classified or unclassified with a minimum weight of 1.84 pounds per square foot. 1/4 thick Georgia Pacific Dens-Deck or Sound Deadening Board with a minimum weight of 1.09 pounds per square foot may be substituted for 1/2 thick gypsum wallboard beneath the insulation. On Reroof/No Tearoff projects, where the existing roof is Class A rated, the gypsum board may be eliminated. Existing roofs that are Class B or C rated will require the use of gypsum board to achieve a Class A rating, otherwise, the new roofing system will retain the existing UL rating. (5) joints (bottom layer) must be staggered a minimum of 6 inches from joints in wood deck. 2 1 Aqua Base 120 Codes - 2/2012
3 Underwriters Laboratories VersiFleece TPO 100, 115 or 135 Membrane (white, tan or gray) UL Class B * Thickness Combustible Polyisocyanurate (listed on previous page)/g2 Base Sheet (5) Versico Recovery Board(4)/Polyisocyanurate/ G2 Base Sheet(5) Versico Recovery Board(4)/G2 Base Sheet(5) 1-1/2 Min./ G2 Base Sheet 1/2 Min./1 Min./ G2 Base Sheet 1 Min./ G2 Base Sheet 1/2" 1" Versico SecurShield Polyisocyanurate (3) 1.9 Min. 1/2" * As an option to adhering the VersiFleece Membrane with Aqua Base 120 Bonding Adhesive, the membrane can be loose-laid and mechanically fastened to the roof deck in accordance with Versico s VersiFleece Specification. : (1) When multiple insulation layers are listed (i.e. Versico Recovery Board/Polyisocyanurate), the insulation listed first (Versico Recovery Board) is directly under the membrane. (2) may be mechanically fastened or attached with DASH/FAST Adhesive, OlyBond500 BA or hot asphalt. (3) joints (bottom layer) must be staggered a minimum of 6 inches from joints in wood deck. (4) 7/16 thick non-veneer, APA rated oriented strand board (OSB) may be substituted for Versico Recovery Board in all listed assemblies. The fastening pattern for the OSB must conform with Versico Detail A (when mechanically fastened). (5) Acceptable G2 Base Sheets can be one of the following: Celotex Type G2 Vaporbar GB, GAF Gafglas No. 75 Base Sheet, Manville Glasbase, Owens Corning Perma Ply No. 28 or Tamko Glass Base. Versico s FR Base Sheet 2S is also acceptable. 2 Aqua Base 120 Codes - 2/2012
4 VersiFleece TPO 100, 115 or 135 Membrane (white, tan or gray) FM Class 1A-90 Mechanically Attached with Versico Fasteners (1) (2) Thickness New Construction or Steel (Min. 22 gauge) Wood () (6) Structural Concrete Tectum (7) Gypsum (Tearoff only) (8) Retrofit (No Tearoff) (9): Structural Concrete Gypsum (8) Versico Polyisocyanurate MP-H /4" Versico Recovery Board(3) Versico Recovery Board/Polyisocyanurate(3) Versico Recovery Board/XPS (3)(4) Versico Recovery Board/ EPS(3)(4)(5) 1/2 Min. 1/2 /Refer to FM Approval Guide 1 Dens-Deck Prime Dens-Deck Prime/ Above 1/4 Min. 1/4 Min/See Above 1-1/2 Retrofit (No Tearoff) (9): Versico Polyisocyanurate MP-H Steel (min. 22 gauge) or 1 Only 3/4" Tectum Versico Recovery Board 1/2-1 1 When minimum Polyisocyanurate insulation thickness is 1-1/2 (single or top layer) a reduced fastening density of 1 per 4 square feet can be utilized in the field of the roof. (1) Additional insulation fastening is required at perimeter and corners in accordance with FM Loss Prevention Data Sheets 1-28 and (2) Specific information concerning structural deck requirements (brand names, span capacity, securement criteria, etc.) must be referenced in the current FM Approval Guide and FM Loss Prevention Data Sheet 1-28/1-29. (3) 7/16 thick non-veneer, APA rated oriented strand board (OSB) may be substituted for Versico Recovery Board in all assemblies. For applications directly over steel decks, a thermal barrier of 3/4 thick perlite or 5/8 thick type X gypsum board is required beneath OSB. fastening patterns for OSB are identified in the FM Fastening Requirements in this guide. As an alternate, minimum 1/4 thick Georgia Pacific Dens-Deck (minimum 1/2 directly over steel or wood decks) may also be substituted for Versico Recovery Board. (4) On steel decks, a thermal barrier of FM approved perlite or gypsum board (Type X or Type C ) is required under these insulations. For specific thermal barrier requirements, consult the respective insulation manufacturer or refer to current published FM Approval Guide. (5) EPS insulation must be supplied by an FM approved manufacturer. (6) On FM approved wood decks, minimum 1/4 thick gypsum board must be installed beneath the insulations listed. Polystyrene insulations must incorporate 1/4 gypsum board in addition to standard thermal barrier requirements. (7) FM approved Tectum decks must be minimum 2 thick. If mechanical fastening of insulation is specified, insulation fasteners must penetrate the deck a minimum of 2 (minimum 1-1/2 penetration acceptable for FM 1-60 rating). (6) Existing gypsum decks must be FM approved. If mechanical fastening of insulation is specified, insulation fasteners must penetrate deck a minimum of 1-1/2. (7) Existing roof must be FM Class 1 rated. 3 Aqua Base 120 Codes - 2/2012
5 VersiFleece TPO 100, 115 or 135 Membrane (white, tan or gray) FM Class 1A-120 Mechanically Attached with Versico Fasteners (1) New Construction or Steel (Min. 22 gauge) Structural Concrete Retrofit (No Tearoff) (5): Structural Concrete Versico Polyisocyanurate MP-H Thickness (2) (top layer) Min. 2 (3) Min. 1-1/2 (4) Versico Polyiso MP-H/OSB Composite (1) Additional insulation fastening is required at perimeters and corners in accordance with FM Loss Prevention Data Sheets 1-28 and (2) For maximum thickness of insulation permitted, refer to page 4. (3) Testing conducted on 22 gauge standard FM approved steel deck secured as outlined in the FM Approval Guide and FM Loss Prevention Data Sheet 1-28/1-29. Additional deck fastening is required at roof perimeters and corners. (4) Testing conducted on minimum 22 gauge, Grade E steel decking meeting ASTM A611 or A653 Grade 80. (5) Existing roof must be FM Class 1 rated. 3/4 4 Aqua Base 120 Codes - 2/2012
6 VersiFleece TPO 100, 115 or 135 Membrane (white, tan or gray) FM Ratings Secured to Structural Concrete with DASH/FAST Adhesive New Construction or Structural Concrete Thickness Uplift Rating Versico Polyisocyanurate MP-H /4" Dens-Deck Prime Min. 1/4 Dens-Deck Prime/Polyisocyanurate Dens-Deck Prime/XPS ** Oriented Strand Board/Polyisocyanurate Versico Recovery Board Versico Recovery Board/Polyisocyanurate Versico Recover Board/XPS** Versico Recovery Board/EPS * Dens-Deck Prime/EPS * Versico Polyiso Versico MP-H/OSB Composite Min. 1/4 / See Above Min. 1/4 /FM approved 7/16 /See Above 1/2 Min. 1/2 /See Above 1/2 /FM approved 1/2 /FM Approved Min. 1/4 / / / * EPS must be FM approved and manufactured from BASF, Huntsman or Nova Beads. ** Approved Extruded Polystyrene insulation includes Owens Corning Thermapink/Foamular, DOW Styrofoam and Pactiv. Note: (1) SH hail rating with VersiFleece membrane is pending. 5 Aqua Base 120 Codes - 2/2012
7 VersiFleece TPO 100, 115 or 135 Membrane (white, tan or gray) FM Class 1A-150 OSB Mechanically Fastened; Membrane adhered with Aqua Base 120 Bonding Adhesive Thickness New Construction or Steel (1) OSB (2) over Polyiso 7/16 /See Page 5 1 FM Class 1A-90 Rating - Attachment to Gypsum with FAST 100-LV Adhesive Thickness New Construction/ Versico Polyiso MP-H /4" Versico Recovery Board 1/2 Min. Gypsum (3) Min. 1/2 Versico Versico Recovery Board or Min. 1/4 Versico Dens-Deck Prime(6) Over: Polyisocyanurate Extruded Polystyrene(3) 1 Expanded Polystyrene(4) See Above (1) Minimum 22 gauge FM approved steel deck is secured to minimum 1/4 thick steel structural supports spaced a maximum 6 on center with ITW Buildex TRAXX 5 Fasteners spaced 6 on center. Deck side laps secured maximum 30 on center with ITW Buildex TRAXX 1 Fasteners. (2) OSB is mechanically fastened at the rate of 17 fasteners per 4 x 8 board in the field of the roof with fastening enhancements required at perimeters and corners as outlined in the back of this Approval Guide. (3) Existing gypsum deck must be. 6 Aqua Base 120 Codes - 2/2012
8 VersiFleece TPO 100, 115 or 135 Membrane (white, tan or gray) FM Class 1A-90 Base Layer of Mechanically Fastened; Top Layer of Attached with FAST 100 or 100-LV Adhesive; Membrane adhered with Aqua Base Bonding Adhesive (1) New Construction or Wood (2) Tectum (3) Gypsum (4) (Tearoff Only) Base layer of FM approved Polyisocyanurate insulation (minimum thickness listed on page 4) mechanically fastened to the deck per standard FM Class 1-90 requirements (including enhancements at perimeters and corners). Top Layer of minimum 1/2 thick Versico Recovery Board, 1/4 thick Dens-Deck/Dens- Deck Prime or Polyisocyanurate (from page 4) secured over base layer with DASH/FAST Adhesive 1 with top layer of Versico Recovery Board 1-1/2 with top layer of Dens-Deck Prime 3/4 with top layer of Polyiso (1) Specific information concerning structural deck requirements (brand names, span capacity, securement criteria, etc.) must be referenced in the current FM Approval Guide and FM Loss Prevention Data Sheet 1-28/1-29. (2) On FM approved wood decks, minimum 1/4 thick gypsum board must be installed beneath the insulation listed. (3) FM approved Tectum decks must be minimum 2 thick. fasteners must penetrate the deck a minimum 1-1/2 for FM 1-60 ratings. (4) Existing gypsum decks must be FM approved. fasteners must penetrate the deck a minimum of 1-1/2. 7 Aqua Base 120 Codes - 2/2012
9 (Over Lightweight Insulating Concrete and Tectum Substrates) VersiFleece TPO 100, 115 or 135 Membrane (white, tan or gray) FM Class 1A-90 Application Over Tectum Decks Secured with FAST 100 or 100 LV Adhesive; Membrane Adhered with Aqua Base 120 Bonding Adhesive Thickness Tectum (1) Note: Versico Polyisocyanurate MP-H 1 Min 3/4 Versico Recovery Board/Polyiso 1/2 /(See Above) 1 (1) FM approved minimum 2 thick by 31 wide Tectum deck secured to minimum 1/4 thick steel supports spaced a maximum of 3 on center with two Construction Fasteners, Inc. 2 diameter metal plates and #14 Dekfast Fasteners per panel per support. Screws are driven into 7/32 diameter pilot holes and are spaced 7-1/2 from panel edges. Additional deck fastening required at perimeters and corners per FM Loss Prevention Data Sheet 1-28/ Aqua Base 120 Codes - 2/2012
10 VersiFleece TPO 100, 115 or 135 Membrane (white, tan or gray) Existing FM Rating Retained Secured with FAST 100 or 100-LV Adhesive; Membrane Adhered with Aqua Base 120 Bonding Adhesive Thickness Retrofit (No Tearoff) (1): FM approved roof decks: Steel Wood Tectum Versico Polyisocyanurate MP-H 1 Only 3/4" Versico Recovery Board ½ - 1 1" Retrofit (No Tearoff) (1): FM approved roof decks: Structural Concrete Lightweight Insulating Concrete Gypsum Versico Polyisocyanurate MP-H /4" Versico Recovery Board Versico Recovery Board/ Polyisocyanurate ½ Min. ½ Min/See Above 1" (1) Existing wet materials must be removed and blisters shall be cut out. All gravel must be removed from the roof surface. The existing roof must be adequately secured. Refer to FM Loss Prevention Data Sheet 1-29 for specific guidelines. (2) Existing FM Class 1, type III or IV smooth asphalt BUR, mineral surface cap sheet or modified bitumen. 9 Aqua Base 120 Codes - 2/2012
11 (In conjunction with Versico 725 Vapor Retarder) VersiFleece TPO 100, 115 or 135 Membrane (white, tan or gray) FM Class 1A-120 Utilizing Versico 725 TR Vapor Retarder/Cav-Grip Primer Secured with FAST 100 or 100-LV Adhesive; Membrane adhered with Aqua Base 120 Bonding Adhesive New Construction or Steel (1) (Base Layer Below Vapor Retarder) Min. 1/2 Dens-Deck Prime (2) mechanically fastened over steel deck Install Versico 725 TR Vapor Retarder after applying CCW Cav-Grip Primer (Top Layer Above Vapor Retarder) Single or Multiple Layers of Min. 1-1/2 Thick Polyiso (3) or Min. 1-1/2 Thick Polyiso (3) overlaid with 1/2 Thick Versico Recovery Board, min. 1/4 Dens- Deck Prime or 7/16 OSB set in DASH/FAST Adhesive over Versico 725 TR Vapor Retarder (4) 3/4 (over Polyiso) 1" (over Versico Recovery Board or OSB 1-1/2" over Dens-Deck Prime New Construction or Structural Concrete Utilizing Versico 725TR Vapor Retarder/702 LV or Cav-Grip Primer Secured with FAST 100 or 100-LV (5) Adhesive; Membrane adhered with Aqua Base 120 Bonding Adhesive FM Thickness Rating VersiGard White Min. 1 thick Polyiso (3) set in DASH/FAST Adhesive over Versico 725 TR Vapor Retarder (4) 1A-945 3/4" Min. 1/4 Dens-Deck/ Dens-Deck Prime or 7/16 OSB over min. 1 Polyiso (3) set in DASH/FAST Adhesive over Versico 725 TR Vapor Retarder 1A /2" (over Dens-Deck) 1" (over OSB) 1/2 Versico Recovery Board over Minimum 1 Polyiso (3) set in DASH/FAST Adhesive over Versico 725 TR Vapor Retarder (4) 1A-660 1" (1) Testing conducted on Minimum 22 gauge Grade E steel decking meeting ASTM A611 or A653 Grade 80 (2) Minimum 1/2 thick Georgia Pacific Dens-Deck Prime base layer must be mechanically fastened at the minimum rate of 1 per 2 square feet in the field of the roof. Additional insulation fastening is required at perimeters and corners in accordance with FM Loss prevention Data Sheets 1-28 and (3) Approved Polyisocyanurate insulation includes those listed on page 5 in this Code Approval Guide. Attach insulation to the Versico 725 Vapor Retarder with DASH/FAST Adhesive as outlined in Versico s Specifications. (4) Prior to installing Versico 725 Vapor Retarder, apply Versico 702 Primer as outlined in Versico s Specification. 10 Aqua Base 120 Codes - 2/2012
12 VersiFleece Adhered Roofing Systems Membrane adhered with Aquabase 120 Bonding Adhesive VersiFleece TPO 100, 115 or 135 Membrane (white, tan or gray) FM Class 1A-300 Rating - Attachment with Hot Asphalt (1) New Construction/ Structural Concrete Thickness Versico Polyiso MP-H 1-12 Versico Recovery Board Versico Recovery Board or Dens-Deck Prime over Polyiso 1/2 Min. 1/2 Min/ See above Bonding Adhesive Aqua Base 120 3/4" 1 with top layer of Versico Recovery board 1-1/2 with top layer of Dens-Deck Prime (2) New Construction or Steel (Min. 22 gauge) Wood (3) Tectum (4) Gypsum (5) (Tearoff Only) FM Class 1A-90 Ratings Base Layer Mechanically Fastened; Top Layer of Attached with Hot Asphalt (1) Base layer of 1/2 thick Dens-Deck/Dens- Deck Prime (6) or FM approved Polyisocyanurate insulation (minimum thickness listed above) mechanically fastened to the deck per standard FM Class 1-90 requirements (including enhancements at perimeters and corners). 1 with top layer of Versico Recovery Board 3/4 with top layer of Polyiso Top Layer of minimum 1/2 thick Versico Recovery Board, Dens-Deck Prime or FM Approved Polyisocyanurate (listed above) secured over base layer with hot asphalt 1-1/2" with top layer Dens-Deck Prime (1) Hot asphalt must be Type III or IV applied at a temperature within 25 F of EVT at the rate of pounds per square. (2) Specific information concerning structural deck requirements (brand names, span capacity, securement criteria, etc.) must be referenced in the current FM Approval Guide and FM Loss Prevention Data Sheet (3) On FM approved wood decks, minimum 1/4" thick gypsum board must be installed beneath the insulations listed. (4) FM approved Tectum decks must be minimum 2" thick. Fasteners must penetrate the deck a minimum 2". (5) Existing gypsum decks must be FM approved. fasteners must penetrate the deck a minimum of 1-1/2". (6) 1/2 thick Dens-Deck or Dens-Deck Prime must be fastened to the deck at 1 per 2 square feet (enhancements required at perimeters and corners). 11 Aqua Base 120 Codes - 2/2012
13 Design A Fully Adhered Roofing Systems VersiFleece 100, 115 or 135 Membrane (white, tan or gray TPO) FM Class 1A-300 Rating Attachment to Structural Concrete with OlyBond500 BA Adhesive (1) Thickness New Construction/ Structural Concrete Versico Polyiso MP-H /4" Versico Dens-Deck Prime Min. 1/4 / Over Polyisocyanurate See Above 1-1/2 FM Class 1A-555 Ratings Attachment to Structural Concrete with OlyBond500 BA Adhesive (1) Thickness New Construction/ Structural Concrete Versico Dens-Deck Prime/XPS (2) Min. 1/4 / 1-1/2 FM Class 1A-240 Ratings Attachment to Structural Concrete with OlyBond500 BA Adhesive (1) Thickness New Construction/ Structural Concrete Versico Recovery Board 1/2 Min. 1/2 Versico Recovery Board over: Polyisocyanurate See Page 12 XPS (2) EPS * Versico Dens-Deck Min. 1/4 / 1-1/2" Prime/EPS * * EPS must be FM approved and manufactured from Western Insulfoam or Western EPS (Min. 2 thick). 1) OlyBond500 BA Adhesive is applied in continuous 3/4 wide beads spaced a maximum of 12 on center to the substrate in the field of the roof. is placed into adhesive after it is allowed to rise and string prior to walking and rolling the board into place. Reference Versico s Technical Data Bulletin (TDB) for installation requirements. 2) Extruded Polystyrene must be Owens Corning Foamular (Min. 2 thick) Aqua Base 120 Codes - 2/2012
14 Design A Adhered Roofing Systems VersiFleece TPO 100, 115 or 135 Membrane (white, tan or gray) FM Class 1A-90 Rating Attachment to Tectum or Gypsum with OlyBond500 BA Adhesive (1) New Construction/ Tectum (2) (2 min. deck thickness) Gypsum (4) Thickness VersiGard VersiGard White Versico Polyiso MP-H /4" 3/4" 3/4" Versico Recovery Board 1/2 Min. 1 with top layer 1 with top layer of Versico of Versico Recovery Board Recovery Board Min. 1/2 Versico Recovery Board or Min. 1/4 Versico Dens-Deck Prime Over: Polyisocyanurate XPS(3) EPS* See Above 1-1/2" with top layer Dens-Deck Prime 1 with top layer of Versico Recovery Board or Dens-Deck Prime 1-1/2" with top layer Dens-Deck Prime * EPS must be FM approved and manufactured from Western Insulfoam or Western EPS (Min. 2 thick). (1) OlyBond500 BA Adhesive is applied in continuous 1/2 wide beads spaced a maximum of 12 on center to the substrate in the field of the roof. is placed into adhesive after it is allowed to rise and string prior to walking and rolling the board into place. Reference Versico s Technical Data Bulletin (TDB) for installation requirements. (2) FM approved minimum 2 thick by 31 wide Tectum deck secured to minimum 1/4 thick steel supports spaced a maximum of 3 on center with two Construction Fasteners, Inc. 2 diameter metal plates and #14 Dekfast Fasteners per panel per support. Screws are driven into 7/32 diameter pilot holes and are spaced 7-1/2 from panel edges. Additional deck fastening required at perimeters and corners per FM Loss Prevention Data Sheet (3) Extruded Polystyrene must be Owens Corning Foamular (Min. 2 thick). (4) Existing Gypsum deck must be. 13 Aqua Base 120 Codes - 2/2012
15 Design A Adhered Roofing Systems VersiFleece TPO 100, 115 or 135 Membrane (white, tan or gray) FM Class 1A-90 Ratings Base Layer Mechanically Fastened; Top Layer of Attached with OlyBond500 BA Adhesive (1)(2) (2) New Construction or Steel (Min. 22 gauge) Wood (3) Tectum (4) Gypsum (5) (Tearoff Only) Base layer of 1/2 thick Dens-Deck/Dens-Deck Prime (6) or FM approved Polyisocyanurate insulation (minimum thickness listed above) mechanically fastened to the deck per standard FM Class 1-90 requirements (including enhancements at perimeters and corners). Top Layer of minimum 1/2 thick Versico Recovery Board or 1/4 thick Dens-Deck Prime Polyiso-cyanurate (See Page 12) secured over base layer with OlyBond500 BA Adhesive 1 with top layer of Versico Recovery Board 1-1/2" with top layer of Dens-Deck Prime 3/4 with top layer of Polyiso (1) OlyBond500 BA Adhesive shall be applied in accordance with Versico Specifications. (2) Specific information concerning structural deck requirements (brand names, span capacity, securement criteria, etc.) must be referenced in the current FM Approval Guide and FM Loss Prevention Data Sheet (3) On FM approved wood decks, minimum 1/4" thick gypsum board must be installed beneath the insulations listed. (4) FM approved Tectum decks must be minimum 2" thick. Fasteners must penetrate the deck a minimum 2". (5) Existing gypsum decks must be FM approved. fasteners must penetrate the deck a minimum of 1-1/2". (6) 1/2 thick Dens-Deck or Dens-Deck Prime must be fastened to the deck at 1 per 2 square feet (enhancements required at perimeters and corners) Versico Versico, and VersiFleece are Trademarks of Versico 14 Aqua Base 120 Codes - 2/2012
Code Approval Guide Table of Contents February 2012
Code Approval Guide Table of Contents February 2012 Page General Guidelines for UL and FM Code Compliance UL and FM Code Approvals: Sure-Flex/Sure-Flex KEE Mechanically Fastened or RhinoBond Roofing Systems:
More informationCode Approval Guide. Underwriters Laboratories Factory Mutual. March 2005
Code Approval Guide Underwriters Laboratories Factory Mutual March 2005 Versico Incorporated, PO Box 1289, Carlisle, PA 17013 Phone 800-992-7663 Internet Address: http://www.versico.com Code Approval Guide
More informationCode Approval Guide. Underwriters Laboratories FM Approvals. February 2012
Code Approval Guide Underwriters Laboratories FM Approvals February 2012 Carlisle SynTec, a division of Carlisle Construction Materials Incorporated P. O. Box 7000, Carlisle, PA 17013-0925 Phone 800-479-6832
More informationCode Approval Guide January, 2017
Table of Contents Introduction... ii Guidelines... iii SureFlex Mechanically Fastened or Induction Welding Roofing Systems: UL Approvals: NonCombustible ANSI UL Class A... 4 Combustible ANSI UL Class A...
More informationSure-Weld (TPO) Adhered Roofing Systems Code Approval Guide January, Table of Contents
(TPO) Adhered Roofing Systems Code Approval Guide January, 2017 Introduction... ii Guidelines... Mechanically Fastened or Induction Welding Roofing Systems UL Approvals NonCombustible ANSI UL Class A...
More informationC. Applicable building codes should always be checked prior to proposing the application to Mule-Hide or the building owner.
1.0 Insulation Guidelines A. The following is a list of generic insulations acceptable for use with Mule-Hide Single Ply Roofing Systems. Requests to use other types of insulation boards are to be made
More informationROOFING INSTALLATION GUIDELINES
ROOFING INSTALLATION GUIDELINES PREPARATION FOR NEW CONSTRUCTION AND REROOF: ALL DECK TYPES Sweep and remove all loose particles and debris from the roof deck surface. The roof deck should be sound, smooth,
More informationUL Listing: EPDM Roofing Systems
Commercial/Industrial Roofing Systems UL Listing: EPDM Roofing Systems SINGLE PLY MEMBRANE ROOFING SYSTEMS In the fully adhered and mechanically fastened systems described below, the ".045 EPDM" membrane
More informationEXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT (203)
EVALUATION REPORT Mule-Hide Products Co., Inc. 1195 Prince Hall Drive Beloit, WI 53511 (608) 365-3111 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street Oxford, CT
More informationNEMO etc. Certificate of Authorization # Christian Street, Unit #13 Oxford, CT (203)
Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY Mule-Hide Products Co., Inc. 1195 Prince Hall Drive Beloit, WI
More informationSection Property Standard Year Wind FM Physical Properties ASTM D
ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Single Ply Roof Systems Compliance Statement: Carlisle Single Ply Roof Systems, as produced by Carlisle SynTec Incorporated,
More informationESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years.
ICC-ES Evaluation Report ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:
More informationExterior Research & Design, L.L.C. Building Science and Envelope Consultants
Exterior Research & Design, L.L.C. Building Science and Envelope Consultants Certificate of Evaluation Report 3520.03.04-R2 Evaluation of Roof s for Florida Product Approval #FL2533-R2 Prepared for: CertainTeed
More informationMechanically Attached and Fully Adhered Roofing Systems
Mechanically Attached and Fully Adhered Roofing Systems January 2019 TABLE OF CONTENTS Part I General 1.01 Description... 3 1.02 General Design Considerations... 4 1.03 Quality Assurance... 5 1.04 Submittals...
More informationEXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT PHONE: (203) FAX: (203)
EVALUATION REPORT Carlisle SynTec Systems P.O. Box 7000 Carlisle, PA 17013 (717) 245-7264 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street Oxford, CT 06478 PHONE:
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationRecommended Fastening Patterns for Rmax Insulation in Low Slope Roofing Applications
Recommended Fastening Patterns for Rmax Insulation in Low Slope Roofing Applications INTRODUCTION Rmax recommends that any insulation which is laid over a steel or wood roof deck be attached with mechanical
More informationPRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationFOAMULAR Commercial Roofing
Low Slope Insulated Roof Systems Roofing Systems Single-ply roofing s are flexible sheets of compounded synthetic materials that are manufactured in a factory. Single ply roof systems provide strength,
More informationPRODUCT CONTROL SECTION
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3909 Issued 07/2017 This report is subject to renewal 07/2018. DIVISION: 07 00 00
More informationUL Evaluation Report UL ER Issued: June 29, 2015 Revised: July 29, UL Category Code: ULFB. CSI MasterFormat
UL Evaluation Report UL ER1306-01 Issued: June 29, 2015 Revised: July 29, 2015 Visit UL s On-Line Certifications Directory: www.ul.com/erdirectory for current status of Report. UL Category Code: ULFB CSI
More informationEXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT PHONE: (203) FAX: (203)
EVALUATION REPORT Mule-Hide Products Co., Inc. 1195 Prince Hall Drive Beloit, WI 53511 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street Oxford, CT 06478 PHONE: (203)
More informationAdhesive Pull Test Standard Testing Procedures
Determining Adhesive Strength 1. The test sample should include the following components: a. Substrate (bare deck or existing roof). b. Vapor or air barrier if included in the new system. c. First insulation
More information2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (RAS)
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES 1.. 3. Scope
More informationTGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance
1 of 6 5/8/2012 4:19 PM TGIK.R9734 Roofing Systems, Uplift Resistance Page Bottom Roofing Systems, Uplift Resistance See General Information for Roofing Systems, Uplift Resistance KELLY CO-2001 INC 325
More informationMechanically Attached and Fully Adhered Roofing Systems
Mechanically Attached and Fully Adhered Roofing Systems January 2012 TABLE OF CONTENTS Part I General 1.01 Description... 3 1.02 General Design Considerations... 4 1.03 Quality Assurance... 5 1.04 Submittals...
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationPRODUCT CONTROL SECTION
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationPOLYISO Polyisocyanurate Roofing Insulation
POLYISO Polyisocyanurate Roofing Insulation TM Above all. WHEN YOU NEED A GO-TO PRODUCT, STOP RIGHT HERE Polyiso is one of the most effective and economical insulation products in the roofing industry.
More informationPRODUCT CONTROL SECTION
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590
More informationMechanical Attachment of Separation Panels Hot Asphalt Attachment of Separation Panels
Table of Contents Title Number General.01.1 Types and Mandatory Compliances.02.1 Installation.03.1 Attachment.04.1 Mechanical Attachment of.04.1.1 Hot Asphalt Attachment of.04.1.2 Cold Adhesive Attachment
More informationTGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance
UL TGIK.R9734 Roofing Syst. Uplift Resistance * www.2001company.com * 1.800.537.7663 * Page 1 of 6 Page 1 of 6 Page Bottom TGIK.R9734 Roofing Systems, Uplift Resistance Roofing Systems, Uplift Resistance
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationRe-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY
Insulation for Above the Deck WALL SPECIALTY PRODUCT DESCRIPTION Rmax Re-Cover Board-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded
More informationFirestone Polyiso Boards
Firestone Polyiso Boards Superior energy efficiency. Superior protection. Firestone Polyiso Boards POLISOBROUK10.indd 1 1/04/10 14:26 Firestone Polyiso Boards Firestone total roofing systems Since Firestone
More informationUL Evaluation Report UL ER Issued: December 19, 2014 Revised: August 14, UL Category Code: ULFB. CSI MasterFormat
UL Evaluation Report UL ER9516-02 Issued: December 19, 2014 Revised: August 14, 2015 Visit UL s On-Line Certifications Directory: www.ul.com/erdirectory for current status of Report. UL Category Code:
More informationExterior Research & Design, L.L.C. Building Science and Envelope Consultants
Exterior Research &, L.L.C. Building Science and Envelope Consultants Certificate of Authorization #9503 Evaluation Report 00256.09.06 Evaluation of Roofing s for Florida Product Approval #FL7508 Prepared
More informationPRODUCT CONTROL SECTION
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590
More informationMechanically Attached and Fully Adhered Roofing Systems. Part I Design Criteria
Mechanically Attached and Fully Adhered Roofing Systems Part I Design Criteria TABLE OF CONTENTS April 2010 Page A. Description... 2 B. General Design Considerations... 2 C. Quality Assurance... 4 D. Warranty...
More informationUL Evaluation Report UL ER Issued: July 25, UL Category Code: ULFB. CSI MasterFormat
UL Evaluation Report UL ER10167-01 Issued: July 25, 2014 Visit UL s On-Line Certifications Directory: www.ul.com/erdirectory for current status of Report. UL Category Code: ULFB CSI MasterFormat DIVISION:
More informationPRODUCT CONTROL SECTION
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER: POLYGLASS USA, INC.
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2018 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 07 00
More informationEXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT (203)
EVALUATION REPORT Johns Manville Corporation P.O. Box 5108 Denver, CO 80217 (303) 987-4879 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street Oxford, CT 06478 (203)
More informationNEMO etc. Certificate of Authorization # Christian Street, Unit #13 Oxford, CT (203)
Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY Firestone Building Products Company, LLC. 200 4 th Avenue South
More informationB u l l e t i n SOPRABOARD MECHANICALLY FASTENED OVER POLYISOCYANURATE INSULATION BOARD (PARS) PARTIALLY ATTACHED (HYBRIDE) ROOFING SYSTEM
B u l l e t i n File Number: Test Date: 2016-08-23 Publication Date: 2016-12-21 Reappraisal Date: 2019-12-21 SOPRABOARD MECHANICALLY FASTENED OVER POLYISOCYANURATE INSULATION BOARD (PARS) PARTIALLY ATTACHED
More informationPRODUCT CONTROL SECTION
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590
More informationHALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS
SECTION 075216 - PART 1 - GENERAL 1.1 SUMMARY A. Section includes styrene-butadiene-styrene (SBS) modified bituminous membrane roofing. 1.2 DEFINITIONS A. Hot Roofing Asphalt: Roofing asphalt heated to
More informationG October 2018
G-13-18 VacuSeal TM Vent Secured Roofing Systems October 2018 The information contained in this supplement serves as a criteria for Specifiers and Authorized Applicators regarding the design and installation
More informationPRODUCT CONTROL SECTION
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590
More informationICC-ES Evaluation Report. ESR-3297 Reissued March 1, 2013 This report is subject to renewal May 1, 2014.
ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-3297 Reissued March, 203 This report is subject to renewal May, 204. A Subsidiary the International Code Council DIVISION: 07 00
More informationPRODUCT CONTROL SECTION
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590
More informationB u l l e t i n SOPRABOARD MODIFIED BITUMEN SYSTEM (PARS) PARTIALLY ATTACHED (HYBRIDE) ROOFING SYSTEM
B u l l e t i n File Numbers: SOPI-216809-12 SOPI-216809-17 SOPI-233880-08 SOPI-233880-12 Test Dates: 2014-08-18 / 2014-12-12 / 2015-04-30 / 2015-06-26 Publication Date: 2015-08-18 Revision Dates: 2015-09-29(R1)
More informationSPECIFICATION SUBMITTAL
101C AWAPLAN PREMIUM INSULATED DECK TAMKO BASE PLY INSULATION 1/2 m = 50 cm = 19-11/16 inches 1 m = 100 cm = 39-3/8 inches Material Requirements TAMKO GLASS-BASE, TAM-GLASS PREMIUM, TAM- PLY IV, or BASE-N-PLY
More informationEngineering Services Program
RC152 1016 Product Evaluation Engineering Services Program The following product has been evaluated for compliance with the wind loads specified in the International Residential Code (IRC) and the International
More informationCoal Tar Application and Design Considerations
Coal Tar Application and Design Considerations 400 Old Reading Pike, Suite 304 Pottstown, PA 19464 Tel: 610-579-9075 Fax: 610-323-0115 www.durapax.com The proper specification of any roof system is extremely
More informationSubject: NRCA MRCA Joint Technical Bulletin. Date: January 2008 NOT COMPROMISE.
Roofing No. 3001 NRCA MRCA Joint Technical Bulletin Attached is a copy of the NRCA/MRCA Joint Technical Bulletin which was presented at the 1987 MRCA Convention. This document is entitled, In-Service R-Values
More informationSPECIFICATION SUBMITTAL
201FRC AWAPLAN 170 FR INSULATED DECK 1/2 m = 50 cm = 19-11/16 inches 1 m = 100 cm = 39-3/8 inches Material Requirements TAMKO GLASS-BASE, TAM-GLASS PREMIUM, TAM- PLY IV, or BASE-N-PLY Fiberglass Sheet
More informationFully Adhered Roofing Systems
Fully Adhered Roofing Systems July 2018 TABLE OF CONTENTS Part I General Page 1.01 Description... 3 1.02 Design Considerations... 3 1.03 Quality Assurance... 5 1.04 Submittals... 5 1.05 Warranty... 6 Warranty
More informationJ&L Building Materials, Inc. Commercial Roofing
J&L Building Materials, Inc. Commercial Roofing SBS & APP MODIFIED CERTAINTEED MODIFIED BITUMEN FLINTLASTIC GMS SBS MODIFIED BITUMEN ROLL ROOFING PRODUCTS 8 colors match to match Landmark shingles. SBS
More informationShort Form Guide Specification. Specifying Extruded Polystyrene Roof Insulation- STYROFOAM DECKMATE Plus Tapered
07 22 16.13 Short Form Guide Specification Specifying Extruded Polystyrene Roof Insulation- STYROFOAM DECKMATE Plus Tapered June 2006 SPEC NOTE: This guide specification is intended for use when specifying
More informationESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.
ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015. A Subsidiary of the International Code Council DIVISION:
More informationROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL
ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL PART 1 GENERAL 1.1 SECTION INCLUDES A. Insulation, membrane roofing, base flashings roofing membrane accessories joints, and counter flashings.
More informationCREEK Technical Services, LLC
a CREEK Certificate of Authorization 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6 TH EDITION (2017) Manufacturer: FIRESTONE BUILDING PRODUCTS CO.,
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationB u l l e t i n MODIFIED BITUMEN MEMBRANES OVER SOPRABOARD SYSTEM (AARS) ADHESIVE APPLIED ROOFING SYSTEM
B u l l e t i n File Number: Test Date: 2015-09-16 Publication Date: 2017-05-15 Reappraisal Date: 2020-05-15 MODIFIED BITUMEN MEMBRANES OVER SOPRABOARD SYSTEM (AARS) ADHESIVE APPLIED ROOFING SYSTEM Roofing
More informationThermoplastic Single Ply & Multi-Ply Roofing Systems
Thermoplastic Single Ply & Multi-Ply Roofing Systems COMMERCIAL INDUSTRIAL INSTITUTIONAL RESIDENTIAL Specializing in Roof Solutions for over 25 years FlexRoofingSystems.com Thermoplastic Single Ply Roof
More informationPRODUCT CONTROL SECTION
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590
More informationB u l l e t i n SOPRA-ISO MECHANICALLY FASTENED AND SOPRABOARD ADHERED SYSTEM (PARS) PARTIALLY ATTACHED (HYBRIDE) ROOFING SYSTEM
B u l l e t i n File Number: Test Date: 2016-02-19 Publication Date: 2017-03-01 Reappraisal Date: 2020-03-01 SOPRA-ISO MECHANICALLY FASTENED AND SOPRABOARD ADHERED SYSTEM (PARS) PARTIALLY ATTACHED (HYBRIDE)
More informationPRODUCT CONTROL SECTION
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: POLYVINYL CHLORIDE ROOFING REPORT HOLDER: IB ROOF SYSTEMS
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 28 Reissued 02/2018 This report is subject to renewal 02/2019. DIVISION: 07 00 00
More informationBridgeton Research Center Roof Replacement and Related Work December 4, 2000 DSR # C/D
SECTION 07220 ROOF INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions, Special Conditions and Division 1 Specification Sections,
More informationPRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationA. National Roofing Contractors Association (NRCA) Roofing and Waterproofing Manual
SECTION 07 22 16 - ROOF AND DECK INSULATION Specifier Note: There are numerous types of roof insulation, some which are installed in multiple-layer roof assemblies. Specifier to verify Project requirements
More informationACFoam-II HCFC Free "Green" Polyiso Specification
ACFoam-II HCFC Free "Green" Polyiso Specification To help owners and specifiers, the following specification strategies are offered as they relate to product performance when including HCFC FREE Green
More informationFASTENING PATTERN GUIDE CONNECTING FUNCTION WITH FACILITY
ACFoam Polyiso Roof Insulation FASTENING PATTERN GUIDE CONNECTING FUNCTION WITH FACILITY CONTENTS Installation Guidelines...3 BUR-8 Built-up or Selected Modified Bitumen Systems...4 FA-8 Fully Adhered
More informationCITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO
SECTION 07220 - ROOF INSULATION PART 1 - GENERAL 1.01 DESCRIPTION A. Work included: The Roofing Contractor will provide all polyisocyanurate insulation and high density wood fiber roof insulation (tapered
More informationSECTION ADHERED SINGLE PLY MEMBRANE ROOFING
SECTION 07535 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered EPDM elastic sheet single ply membrane roofing. B. Related Sections: 1. Section 06100 - Carpentry: Wood deck and curbs. 2. Section
More information4.2 Materials Membranes: inch, inch or inch thick D General
LEGACY REPORT 2403 Reissued April 1, 2005 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office 900
More informationACFoam -III Specifications Atlas Roofing
Division 07 Thermal and Moisture Protection Section 07 22 00 Roof and Deck Insulation Section 07 22 16 - Roof Board Insulation PART 1 GENERAL 1.1 SECTION INCLUDES A. HCFC FREE Polyiso Rigid board type
More informationAPPROVAL REPORT. Anthony Longabard. Project No: Supplements Project No.: N/A Class: 4451 Product Name:
Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT Project No: 3051337 Supplements Project No.: N/A Class: 4451 Product Name: Name of Listing Company: Address
More informationREPORT HOLDER: CARLISLE SYNTEC POST OFFICE BOX 7000 CARLISLE, PENNSYLVANIA EVALUATION SUBJECT:
0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1184 Reissued 03/2017 This report is subject to renewal 03/2019. DIVISION: 07 00 00 THERMAL
More informationMechanically Fastened and Adhered Roofing Systems TABLE OF CONTENTS
Mechanically Fastened and Adhered Roofing Systems TABLE OF CONTENTS June 2008 Part I General 1.01 Description... 3 1.02 General Design Considerations... 3 1.03 Quality Assurance... 4 1.04 Submittals...
More informationDIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1365 Reissued 04/2018 This report is subject to renewal 04/2020. DIVISION: 06 00
More informationEVALUATION REPORT Soprema, Inc. 310 Quadral Drive Wadsworth, OH 44281
EVALUATION REPORT Soprema, Inc. 310 Quadral Drive Wadsworth, OH 44281 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 2 MATTOON ROAD WATERBURY, CT 06488 PHONE: (203) 596-7884 FAX: (203)
More informationCOMMERCIAL ROOFING SYSTEMS
Flex Membrane International Corp. 2670 Leiscz s Bridge Road, Suite 400, Leesport, PA 19533 Tel: 610-916-9500 Fax: 610-916-9501 COMMERCIAL ROOFING SYSTEMS FLEX FB (Fleece Backed) ELVALOY, FLEX MF/R (Smooth
More informationA. Thermal Conductivity: Thicknesses indicated are for thermal conductivity (k-value at 75 degrees F) specified for each material.
SECTION 07 20 00 - PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply
More informationACFoam CrossVent RB Specifications Atlas Roofing
Division 07 Thermal and Moisture Protection Section 07 22 00 Roof and Deck Insulation Section 07 22 16 - Roof Board Insulation PART 1 GENERAL 1.1 SECTION INCLUDES A. HCFC FREE Polyiso Rigid board type
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMOPLASTIC MEMBRANE ROOFING SECTION: POLYVINYL-CHLORIDE ROOFING
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1456 Reissued 08/2018 This report is subject to renewal 08/2019. DIVISION: 07 00
More informationConstruction Standards PAGE
Construction Standards PAGE 072100-1 SECTION 072100 PART 1 - GENERAL 1.1 M.S.U. ISSUES A. It the intent of MSU that insulation of its projects will comply with LEED NC 3 Credit Requirements EA Prerequisite
More informationSECTION CEMENTITIOUS WOOD FIBER DECKS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 03 51 13 CEMENTITIOUS WOOD FIBER DECKS SPEC WRITE NOTES: 1. Delete between // // if not applicable to project. 2. Also delete any other item or paragraph not applicable
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
More informationLamit Industries, Inc. 710 Marion Road Columbus, Ohio P-(614) F-(614)
Lamit Industries, Inc. 710 Marion Road Columbus, Ohio 43207 P-(614)444-3010 F-(614)444-4264 info@lamitindustries.com www.lamitindustries.com SECTION 06120 STRUCTURAL INSULATED PANELS PART 1 GENERAL 1.01
More informationSECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.
SECTION 06 12 00 STRUCTURAL INSULATED PANELS ------------------------------------------------------------------------------------------------------------ PART 1- GENERAL ----------------------------- 1.1
More informationSECTION TEMPORARY ROOFING MEMBRANE INSTALLATION. A. Areas of the roof deck for asbestos abatement.
PART 1 GENERAL 1.01 APPLICATIONS SECTION 07500 TEMPORARY ROOFING MEMBRANE INSTALLATION A. Areas of the roof deck for asbestos abatement. B. Areas of the roof deck exposed to the structural roof deck substrate.
More information