ph Flexibility Expands Robustness and Reproducibility
|
|
- Rosemary Cook
- 6 years ago
- Views:
Transcription
1 ph Flexibility Expands Robustness and Reproducibility High Efficiency Excellent Lifetime ph Stable -
2 Setting the Standard for ph Method Development Gemini columns are rugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible, high efficiency separations. Take full advantage of high and low ph conditions (ph -) to manipulate selectivity Expect longer column lifetime with patented TWIN-NX technology Phase NX-C C-Phenyl C Description The most rugged Gemini column, offering times the durability of previous generation hybrid columns A low bleed phenyl phase for UV and MS detection, which offers an aromatic selectivity complementary to C phases Selectivity, high structural integrity and increased loadability for preparative and purification applications in pre-packed columns and bulk media USP Classification L L L For analytical and preparative separations of basic and acidic compounds TWIN (Two-In-ne) Technology Gemini C and C-Phenyl During the final stage of silica manufacturing a unique silicaorganic layer is grafted to create a completely new composite particle. nce the internal base silica is unaltered by this manufacturing process, the particle retains its mechanical strength and rigidity along with excellent efficiency, while the silica-organic shell protects the particle from chemical attack. Second-Generation TWIN-NX Technology Gemini NX-C TWIN-NX technology uses an improved patented organosilica grafting process which incorporates highly stabilizing ethane cross-linking. These organic groups are evenly incorporated into the grafted layers on the silica surface while maintaining a pure silica core. This not only provides resistance to high ph attack, but also maintains the high efficiency and mechanical strength of a silica particle. H H H R H R R H R H H R H R R R H R H R R R R H H R H R H R R R R R R R R R R R R R CH CH S CH CH CH CH CH CH CH C CH CH CH CH CH CH CH CH C C CH CH CH CH CH CH CH CH CH Phenomenex, Inc. All rights reserved.
3 How It Works Gemini NX-C Ethane Cross-Linking Resists High ph Attack NX-C ph stable - for durability Consistent performance in both volatile and non-volatile buffers High sample loading capacity for metabolite identification and preparative purification Gemini NX-C USP: L LC/MS Certified ph Stability:.. Particle ze: µm, µm, and μm Phase: C Application: Small molecules, basic compounds Strength: Most durable ph stable particle Pore ze (Å): Surface Area (m /g): Carbon Load %: End Capping: TMS Multi-Point Ligand Attachment Resists Low ph Ligand Cleavage Gemini NX-C Tested for Extreme Durability in Changing Mobile Phase ph Column Efficiencies Maintained in High ph Testing for Cycles Vs. Standard lica lica Dissolution % of Initial Efficiencies Stable Efficiencies After Exposure to, Column Volumes of High and Low ph Buffers Diphenhydramine Cycles of Exposure Tetracaine Retention Times of Four Probes Maintained in Neutral ph Testing for Cycles Ligand Cleavage Retention in Minutes Retention Times Maintained After Exposure to, Column Volumes of High and Low ph Buffers Cycles of Exposure Acetophenone Benzene Toluene Acenaphthene Column Used: Column: Gemini µm NX-C Dimensions: x. mm Part No.: F--E
4 NX-C Polar Bases at Low ph (ph.) Phenomenex Gemini µm NX-C Waters XBridge µm C } } Applications The incredible durability across low and high ph ranges for Gemini NX-C analytical and preparative columns gives scientists the ability to get more performance from their "basic" separations. Polar Bases at High ph (ph.) Phenomenex Gemini µm NX-C Waters XBridge µm C App ID, App ID min min Y-axis normalized for all chromatograms Polar Bases (Beta Blockers) at High ph Dimensions: x. mm Mobile Phase: A: mm Ammonium Bicarbonate ph. B: Acetonitrile Gradient: A/B (:) to (:) in min to (:) in min, Hold for min Flow Rate:. ml/min Detection: nm Sample:. Bisoprolol Contaminant. Sotalol. Atenolol. Labetalol (Diastereoisomeric Pair). Nadolol (Diastereoisomeric Pair). Pindolol. Metoprolol. Bisoprolol. Propranolol. Alprenolol App ID, App ID min min Y-axis normalized for all chromatograms Polar Bases (Antihistamines) in Formic Acid Dimensions: x. mm Mobile Phase: A:. % Formic Acid in Water B:. % Formic Acid in Acetonitrile Gradient: A/B (:) to (:) in min Flow Rate:. ml/min Detection: nm Sample:. Pyrilamine. Tripelennamine. Chlorpheniramine. Brompheniramine. Chloropyramine. Diphenhydramine. Loratadine Comparative separations may not be representative of all applications.
5 NX-C Applications Hydrophobic Basic Drugs at Low ph (ph.) Phenomenex Gemini µm NX -C Waters XBridge µm C App ID App ID min min Y-axis normalized for all chromatograms Agilent Technologies ZRBAX µm Extend-C Thermo Scientific Hypersil GLD µm C App ID App ID min min Y-axis normalized for all chromatograms Hydrophobic Bases (Diltiazem, Promethazine) in Formic Acid Columns: Gemini µm NX-C XBridge µm C ZRBAX µm Extend-C Hypersil GLD µm C Dimensions: x. mm Mobile Phase: A:. % Formic Acid in Water B:. % Formic Acid in Acetonitrile Gradient: A/B (:) to (:) in min Flow Rate:. ml/min Detection: nm Sample:. Diltiazem. Promethazine Comparative separations may not be representative of all applications.
6 NX-C Applications Performance in Volatile Buffers With the widespread adoption of LC/MS and LC/MS/MS techniques, column performance in volatile buffers is critical. Phenomenex Gemini µm NX-C Waters XBridge µm C App ID App ID min min Y-axis normalized for all chromatograms Agilent Technologies ZRBAX µm Extend-C Thermo Scientific Hypersil GLD µm C, App ID App ID min min Y-axis normalized for all chromatograms Mixtures of Acids, Neutrals, and Bases in Formic Acid (ph.) Columns: Gemini µm NX-C XBridge µm C ZRBAX µm Extend-C Hypersil GLD µm C Dimensions: x. mm Mobile Phase: A:. % Formic Acid in Water B:. % Formic Acid in Acetonitrile Gradient: A/B (:) to (:) in min, Hold for min Flow Rate:. ml/min Detection: nm Sample:. Pyridine. Quinidine. Sulfathiazole. Triprolidine. Benzyl alcohol. Nortriptyline. Phenol. -Methyl--nitrobenzoic acid. Methylsalicylaldehyde. Hexanophenone Comparative separations may not be representative of all applications.
7 NX-C Applications Performance in Non-Volatile Buffers Gemini was engineered to be the column of choice for pharmaceutical scientists who work with difficult sample mixtures and harsh mobile phase conditions. The consistent performance and rugged phase will provide simplified method development and long column lifetimes. Phenomenex Gemini µm NX-C Waters XBridge µm C App ID App ID min min Y-axis normalized for all chromatograms Agilent Technologies ZRBAX µm Extend-C Thermo Scientific Hypersil GLD µm C,, App ID App ID min min Sample:. Pyridine. Quinidine. Sulfathiazole. Triprolidine. Benzyl alcohol Y-axis normalized for all chromatograms Mixtures of Acids, Neutrals, and Bases in Potassium Phosphate (ph.) Columns: Gemini µm NX-C XBridge µm C ZRBAX µm Extend-C Hypersil GLD µm C Dimensions: x. mm Mobile Phase: A: mm Potassium Phosphate ph. B: Acetonitrile Gradient: A/B (:) to (:) in min, Hold for min Flow Rate:. ml/min Detection: nm. Phenol. Nortriptyline. -Methyl--nitrobenzoic acid. Methylsalicylaldehyde. Hexanophenone Comparative separations may not be representative of all applications.
8 C Increased loading and retention of basic compounds lica efficiency and mechanical strength ph stable for durability Chromatographic Comparisons Phenomenex Gemini µm C Gemini C USP: L LC/MS Certified ph Stability:.. Particle ze: µm, µm, and μm Phase: C Application: Small molecules, basic compounds Strength: Wide ph stability, high efficiency Pore ze (Å): Surface Area (m /g): Carbon Load %: End Capping: TMS Agilent Technologies ZRBAX µm Extend-C Virtually no silanol interactions! min Tricyclic Antidepressants at Neutral ph Dimensions: x. mm Mobile Phase: mm Phosphate buffer, ph./acetonitrile/ Methanol (::) Flow Rate:. ml/min Detection: nm Sample:. Nortriptyline. Imipramine. Amitriptyline. Clomipramine App ID min Advanced Chromatography Technologies ACE µm C min App ID App ID Batch-to-Batch Reproducibility Extended Column Lifetime The TWIN Technology engineering of Gemini provides stability and increased column lifetime. Whether used under isocratic or gradient conditions, Gemini out-performs and outlasts ph stable columns. This is illustrated below. App ID Lifetime and Efficiency Comparison. times increased column lifetime and still going! Batch Batch Batch Batch min Efficiency (N) Columns fail after % loss in efficiency. Gemini Fail Line XTerra Fail Line Conditions for all separations: Column: Gemini µm C Dimension: x. mm Part No.: F--E Mobile Phase: mm Ammonium Bicarbonate, ph./ Acetonitrile (:) Flow Rate:. ml/min Detection: nm Sample:. Pindolol. Metoprolol. Propranolol Days Efficiency and lifetime comparison based on average of two columns each run in parallel. Columns: Gemini µm C Waters XTerra µm MS C Dimensions: x. mm Mobile Phase: Acetonitrile/ mm Methylpyrrolidine Buffer, ph. (:) Flow Rate: ml/min Detection: nm Sample: Diphenhydramine Gemini C Waters XTerra MS C Comparative separations may not be representative of all applications.
9 C-Phenyl ph stable - for durability Great aromatic selectivity Extremely low UV and MS bleed Gemini C-Phenyl USP: L LC/MS Certified ph Stability:.. Particle ze: µm and µm Phase: Phenyl with C linker Application: Aromatic, polar or basic compounds Strength: High aromatic selectivity with exceptional peak shape even in neutral conditions. Extremely low bleed phenyl column. Pore ze (Å): Surface Area (m /g): Carbon Load %: End Capping: TMS Enhanced Performance for Aromatic Compounds Sulfa Drug Application Pursuit µm Diphenyl Gemini µm C-Phenyl Resolution Rs,.. Rs,.. Dimensions: x. mm Mobile Phase:. % Formic Acid in Water/ Methanol (:) Flow Rate:. ml/min Detection: nm Sample:. Sulfathiazole. Sulfamerazine. Sulfamethoxazole mau mau mau mau Phenomenex Gemini µm C-Phenyl Agilent Technologies Pursuit μm Diphenyl App ID min min App ID min min Reproducible Phenyl Phase Low Bleed Phenyl Phase Aliphatic Acid Application.e.e Popular C Intensity cps.e.e.e.e.e.e.e Gemini C-Phenyl Blank min. min Column: Gemini µm C-Phenyl Dimensions: x. mm Part No.: F--E Mobile Phase: mm Phosphate buffer, ph./methanol (:) Flow Rate:. ml/min Detection: nm Sample:. Tartaric Acid. Acetic Acid. Malic Acid. Citric Acid. Lactic Acid. Propionic Acid Dimensions: x. mm Mobile Phase: A:. % Formic acid in Water B:. % Formic acid in Acetonitrile Gradient: % B to % B in min, then hold % B for min Flow Rate:. ml/min MS Detection: ESI + ion mode, M/Z - Comparative separations may not be representative of all applications.
10 Seamlessly Scale-Up to Gemini Axia Packed Prep Columns Axia Packing Technology Axia packed preparative columns involve a single axial compression step unlike conventional packed preparative columns. The ideal column bed density is custom calculated and automated for each specific media and column size. Computer control of the entire process ensures both proper bed density and column uniformity every time. During the Axia packing process, the packing piston is locked in place, eliminating any decompression and then recompression of the media sorbent, thus maintaining media and column bed integrity. This solves common lifetime and performance problems associated with conventional packing processes for preparative columns. Axia Packing Process Involves: Compression Final Column The packing piston head is integrated into the column and locked by the piston retainers, so the pressure is never released. Media packed under ideal pressure Media is never allowed to relax, eliminating voids and dramatically improving reproducibility, column-to-column. Axia Technology vs. Traditional BD Prep Column Packing Traditional Slurry Packing Traditional slurry packing processes, like the Waters BD (ptimum Bed Density) column packing approach, involve the column being removed from the column packing station once it is packed. Several potential problems with this packing method are: Variability in column performance due to increased number of manual operations required for assembly Potential silica media damage during recompression Level of process control is based on traditional slurry packing technology Conventional Packing Process Involves: Compression Decompression Recompression Final Column Pump Column Media escapes from disconnected column Removal of escaped media Media density disruption and potential media crushing lica media packed under liquid pressure Violent recompression of silica media Diagram from Waters Corporation U.S. Patent No.,,
11 See the Difference with Gemini Axia Packed Prep Columns Axia packed columns produce uniform media bed with intact particles The highly tuned patented process and hardware eliminates potential decompression ensuring bed stability and optimal packing density. The media found on the inlet frit of the Axia packed column shows no signs of damage unlike the media found on inlet frit of traditionally packed prep columns. *SEM of Axia inlet frit Intact media at frit surface after packing *SEM of Waters BD inlet frit Traditional packed preparative columns produce non-uniform media beds with sheared and crushed particles Decompression and then recompression during packing can damage the media and lead to increased columnto-column variability, flow disturbances, and decreased column lifetimes. Crushed media or silica fines at frit surface after packing *The images are believed to be representative, but individual columns may vary. Dramatically improve sample resolution, productivity and performance of any preparative column media with Axia column hardware and packing technology. Axia packed prep column offers the opportunity for longer lifetime, higher loading and increased throughput. Phenomenex Gemini µm NX-C Axia Packed Waters XBridge µm C Prep BD % increase in resolution App ID App ID min min Conditions for both columns: Column: Gemini µm NX-C Axia Packed Waters µm XBridge Dimensions: x. mm (Gemini) x mm (XBridge) Mobile Phase: A: mm Ammonium bicarbonate ph. B: Acetonitrile Gradient: Time (min) % B.... Flow Rate: ml/min Temperature: C Detection: nm Sample:. Reserpine. Unknown Key: Best Suited Very Good Packing Material Particle ze (µm) Pore ze (Å) Surface Area (m /g) Carbon Load (%) ph Range Gemini C,,.-. Small Molecules Peptides Proteins Chiral Applications Type of Compounds Loading ligonucleotides Acids Polar Hydrophobic Bases Available Surface Area Gemini C-Phenyl,.-. Gemini NX-C,,.-. Comparative separations may not be representative of all applications.
12 ph Flexibility Allows for Increased Purification Performance Separating basic compounds at higher ph levels produces dramatic changes when compared to low ph conditions. At ph., the basic compounds become neutralized and are more hydrophobic. The retention for the uncharged basic compounds increases providing an increase in separation along with superior peak shapes. Gemini NX-C with. % TFA Gemini NX-C with. % NH H Low ph High ph.. mg in µl App ID. mg in µl App ID min min Column: Gemini µm NX-C Axia Packed Dimensions: x. mm Mobile Phase: A:. % TFA in Water B: Acetonitrile Gradient: % to % B in min Flow Rate: ml/min Detection: nm Sample:. Diphenhydramine. Propranolol Column: Gemini µm NX-C Axia Packed Dimensions: x. mm Mobile Phase: A:. % NH H in Water B: Acetonitrile Gradient: % to % B in min Flow Rate: ml/min Detection: nm Sample:. Diphenhydramine. Propranolol Separation shape improvement provides opportunity for increased loading Gemini NX-C with. % TFA Gemini NX-C with. % NH H Low ph App ID High ph. App ID mg in µl min Column: Gemini µm NX-C Axia Packed Dimensions: x. mm Mobile Phase: A:. % TFA in Water B: Acetonitrile Gradient: % to % B in min Flow Rate: ml/min Detection: nm Sample:. Diphenhydramine. xybutynin. Terfenadine mg in µl min Column: Gemini µm NX-C Axia Packed Dimensions: x. mm Mobile Phase: A:. % NH H in Water B: Acetonitrile Gradient: % to % B in min Flow Rate: ml/min Detection: nm Sample:. Diphenhydramine. xybutynin. Terfenadine ur Phenomenex Gemini and Luna Axia packed columns are the workhorses in our lab. These columns exhibit outstanding performance for challenging separations while also handling a high workload for standard separations. Longevity has also been excellent with some columns lasting years or more. Dependability is so important in my line of work and these columns never disappoint!! -Major Pharmaceutical Company, USA Tip: If you want longer Gemini NX-C Axia packed column lifetimes, request technical note: TN- Increase Column Performance and Lifetime in Peptide and Protein Purification using Aggressive Wash Conditions
13 Core-Shell Technology For Far Greater Performance Use Kinetex Core-Shell Technology! Kinetex EV C: Superior Core-Shell Upgrade Higher sensitivity and efficiency without increase in backpressure Superior peak shape for bases Greater cost savings The unique organo-silica layer of ethane cross-linking found within each Kinetex EV C particle creates a highly inert surface which provides the additional benefit of better peak shape for bases. With the combination of rugged ph stability from - and the core-shell performance advantage, you can easily replace old hybrid silica columns and gain immediate method improvements without increasing backpressure! UHPLC HPLC PREP. µm % higher efficiency than fully porous. µm columns. µm Achieve sub- µm performance on HPLC and UHPLC systems µm µm or better efficiencies at µm pressures for HPLC and PREP LC methods When Compared to Waters XBridge C: Phenomenex Kinetex µm EV C Waters XBridge. µm C mau mau Pressure: bar Pressure: bar EV APP ID APP ID min min What an increase in sensitivity and peak shape! Waters XBridge µm C Column: Kinetex µm EV C XBridge µm C XBridge. µm C Dimensions: x. mm Mobile Phase: A:. % Formic acid in Water B:. % Formic acid in Acetonitrile Gradient: % to % B over minutes Flow Rate:. ml/min Detection: nm Sample:. Uracil. Pindolol. Chlorpheniramine. Nortriptyline. -Methyl--Nitrobenzoic acid. -Methyl Salicyl Aldehyde. Hexaphenone Pressure: bar APP ID min Comparative separations may not be representative of all applications. For rdering Information and to Learn More about the Kinetex Family visit:
14 HPLC Column Protection Protect your Columns from Contaminants Extends HPLC column lifetime Won t alter chromatography Compatible with virtually all HPLC columns Easy to determine when to change cartridge mple to use How Does It Work? The SecurityGuard analytical cartridge holder (patented) directly fingertightens into virtually any manufacturer s column with a female/inverted endfitting. Contaminants are retained by an inexpensive disposable cartridge instead of damaging your valuable HPLC column investment. Cut-away view showing cartridge can be easily inspected for contaminants Increases HPLC Column Lifetime, Guaranteed! mply replace SecurityGuard cartridges instead of your expensive HPLC columns. In this graph, once the expired SecurityGuard cartridge was replaced, the pressure immediately dropped and the column performance was restored allowing for extended column use. Backpressure (Bar) Cartridge Replaced From Injector HPLC Column to Detector - Column returns to initial backpressure Injections Accelerated lifetime test using endogenous biomolecule matrix on a reversed phase C column, µm, x. mm with SecurityGuard C cartridges. Backpressure values represent additional backpressure contributed by SecurityGuard. Universal fingertight quick connection to HPLC column no wrenches required See it in Action! Visit:
15 rdering Information μm Microbore, Minibore and MidBore Columns (mm) SecurityGuard Cartridges (mm) Phases x. x. x. x. x. x. x. x. x. x.* /pk C B--A M--B A--B B--B D--B F--B B--Y D--Y F--Y AJ- C-Phenyl B--A A--B B--B D--B F--B B--Y D--Y F--Y AJ- /pk NX-C B--A M--B A--B B--B D--B F--B B--Y D--Y F--Y AJ- for ID:.-. mm μm Analytical Columns (mm) SecurityGuard Cartridges (mm) Phases x. x. x. x. x. x. x.* /pk C M--D A--E B--E D--E F--E G--E AJ- C-Phenyl A--E B--E D--E F--E G--E AJ- /pk NX-C B--E D--E F--E G--E AJ- for ID:.-. mm μm Minibore and MidBore Columns (mm) SecurityGuard Cartridges (mm) Phases x. x. x. x. x. x. x. x. x.* /pk C A--B B--B F--B G--B B--Y D--Y F--Y G--Y AJ- C-Phenyl A--B B--B F--B B--Y F--Y G--Y AJ- /pk NX-C A--B B--B F--B B--Y D--Y F--Y G--Y AJ- μm Analytical Columns (mm) SecurityGuard Cartridges (mm) Phases x. x. x. x. x. x.* /pk C A--E B--E D--E F--E G--E AJ- C-Phenyl B--E D--E F--E G--E AJ- /pk NX-C B--E D--E F--E G--E AJ- for ID:.-. mm μm Semi-Prep Columns (mm) SecurityGuard Cartridges (mm) Phases x x x /pk C F--N G--N AJ- C-Phenyl G--N AJ- /pk NX-C F--N G--N AJ- for ID: - mm Axia Packed Preparative Columns (mm) for ID:.-. mm For Gemini Capillary HPLC Columns, Guards, and Adapter, contact your Phenomenex technical consultant or local distributor. SecurityGuard Cartridges (mm) Phases x. x. x. x. x x x.** x. μm ea ea C B--P-AX D--P-AX F--P-AX G--P-AX B--U-AX C--U-AX AJ- AJ- C-Phenyl D--P-AX F--P-AX G--P-AX C--U-AX AJ- AJ- μm ea ea NX-C B--P-AX D--P-AX F--P-AX G--P-AX B--U-AX C--U-AX AJ- AJ- μm ea ea C B--P-AX D--P-AX F--P-AX G--P-AX AJ- AJ- μm ea ea NX-C B--P-AX D--P-AX F--P-AX G--P-AX AJ- AJ- for ID: - mm - mm Axia Packed Preparative Columns (mm) continued Axia Packed Preparative Columns (mm) continued SecurityGuard Cartridges (mm) Phases x x x x x x x x. μm Inquire Inquire Inquire ea C D--U-AX F--U-AX G--U-AX B--V-AX AJ- C-Phenyl D--U-AX AJ- μm Inquire Inquire ea NX-C D--U-AX F--U-AX G--U-AX AJ- μm Inquire Inquire Inquire Inquire Inquire Inquire ea C D--U-AX F--U-AX G--U-AX B--V-AX D--V-AX F--V-AX G--V-AX AJ- μm Inquire Inquire Inquire Inquire Inquire Inquire ea NX-C D--U-AX F--U-AX G--U-AX B--V-AX D--V-AX F--V-AX G--V-AX AJ- for ID: - mm If Gemini analytical columns do not provide at least an equivalent separation as compared to a competing column of the same particle size, similar phase and dimensions, return the column with comparative data within days for a full refund. *SecurityGuard Analytical Cartridges require holder, Part No.: KJ- SecurityGuard SemiPrep Cartridges require holder, Part No.: AJ- ** SecurityGuard PREP Cartridges require holder, Part No.: AJ- SecurityGuard PREP Cartridges require holder, Part No.: AJ-
16 ph Flexibility Expands Robustness and Reproducibility Australia t: + ()-- f: + ()-- auinfo@phenomenex.com Austria t: + ()-- f: + ()-- anfrage@phenomenex.com Belgium t: + () (French) t: + () (Dutch) f: + ()- beinfo@phenomenex.com Canada t: + () - f: + () - info@phenomenex.com China t: + () - f: + () - chinainfo@phenomenex.com Denmark t: + f: + nordicinfo@phenomenex.com Finland t: + () f: + nordicinfo@phenomenex.com France t: + () f: + () franceinfo@phenomenex.com Germany t: + ()-- f: + ()-- anfrage@phenomenex.com India t: + ()- f: + ()- indiainfo@phenomenex.com Ireland t: + () f: + - eireinfo@phenomenex.com Luxembourg t: + ()- f: + ()- nlinfo@phenomenex.com Mexico t: --- f: --- tecnicomx@phenomenex.com The Netherlands t: + ()- f: + ()- nlinfo@phenomenex.com New Zealand t: + ()- f: + ()- nzinfo@phenomenex.com Norway t: + f: + nordicinfo@phenomenex.com Puerto Rico t: + () -HPLC f: + () - info@phenomenex.com Spain t: + -- f: + -- espinfo@phenomenex.com Sweden t: + () f: + nordicinfo@phenomenex.com United Kingdom t: + ()- f: + ()- ukinfo@phenomenex.com USA t: + () - f: + () - info@phenomenex.com All other countries Corporate ffice USA t: + () - f: + () - info@phenomenex.com Italy t: + f: + italiainfo@phenomenex.com Terms and Conditions Subject to Phenomenex Standard Terms and Conditions which may be viewed at Trademarks Gemini, Kinetex, and Phenomenex are registered trademarks of Phenomenex. Axia, MidBore, SecurityGuard, TWIN Technology, and TWIN-NX are trademarks of Phenomenex. Hypersil GLD is a registered trademark of Thermo Hypersil-Keystone, Inc. Thermo Scientific is a registered trademark of Thermo Fisher Scientific, Inc. Agilent, Agilent Technologies, Pursuit, and ZRBAX are registered trademarks of Agilent Technologies, Inc. ACE is a registered trademark of Advanced Chromatography Technologies (ACT). Waters, XBridge, and XTerra are registered trademarks and BD is a trademark of Waters Corporation. Disclaimers Comparative separations may not be representative of all applications. Phenomenex is in no way affiliated with Agilent Technologies, Waters Corporation, Thermo Fisher Scientific, or Advanced Chromatography Technologies (ACT). Axia column and packing technology is patented by Phenomenex. U.S. Patent No,,. Gemini and Kinetex EV C are patented by Phenomenex. U.S. Patent Nos.,, and,, and foreign counterparts. Phenomenex, Inc. All rights reserved. BR_W Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com
CHARACTERIZATION & PURIFICATION
Ultra-High Efficiency GFC/SEC BIOMOLECULE CHARACTERIZATION & PURIFICATION AT EXTREMELY AFFORDABLE PRICES AGGREGATES ADC mab BIOSIMILARS NEW 1.8 µm SEC-X1 Replace Waters BEH 1.7 µm SEC columns to: Save
More informationThe New Standard in High Resolution Size Exclusion
The New Standard in High Resolution Size Exclusion Introducing Yarra, Ultra-High Resolution Size Exclusion Columns for Biomolecules 2012 Phenomenex, Inc. All rights reserved. EFFICIENT 3 µm particle size
More informationSee. Beyond HALO. and Sigma-Aldrich Biotechnology. Advanced Materials Technology. Ascentis. Express
See Beyond Advanced Materials Technology HALO and Sigma-Aldrich Biotechnology Ascentis Express See the Performance Difference Decreased secondary interactions with a more inert base material Sharper peaks
More informationNo Lab-Drama Llama is Here
1 No Lab-Drama Llama is Here To Help You Have an Awesome Year! Cool discounts! Details inside... Offers Expire: 29 March 2019 Offer code: CATAF19 HURRY! Place your order and mention the secret code to
More informationPreparative / Process
Preparative / Process HPLC SFC SMB MPLC Capture Concentrate Purify Polish The Bulk Media Partner You Need Phenomenex USA Reception Trust Reliability Performance Welcome to Phenomenex Since 1982 we have
More informationAPPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology
Determination of Impurities and Related Substances for (Ph. Eur. Monograph 8): Increased Sensitivity, Improved Resolution and Faster Analysis Using Kinetex.6 µm Core-Shell LC Columns Ellie Abbasi, Jeff
More informationAPPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology
TN-7 Determination of Impurities and Related Substances for Glibenclamide (EP Monograph 78). Increased Sensitivity, Improved Resolution and Faster Analysis Using Kinetex.6 µm Core-Shell LC Columns Elli
More informationScaling from Analytical to Preparative Chiral Chromatography While Balancing Purity, Yield, and Throughput under HPLC and SFC Conditions
APPLICATINS Scaling from Analytical to Preparative Chiral Chromatography While Balancing Purity, Yield, and Throughput under HPLC and SFC Conditions J Preston, J.T. Presley III, Michael McCoy, Michael
More informationFinally an Easier Solution for Protein Precipitation
Revision: 0 PHEN-RUO-00052 Finally an Easier Solution for Protein Precipitation Rapid Protein Precipitation without the Complications Fast Analysis Save time and increase efficiency by performing precipitation
More informationClarity BioSolutions For Synthetic DNA/RNA Advance Your. Oligonucleotide Work. From Sample Preparation to Analysis and Purification
Clarity BioSolutions For Synthetic DNA/RNA Advance Your Oligonucleotide Work From Sample Preparation to Analysis and Purification Optimized Oligonucleotide Purification and Analysis Designed to efficiently
More informationExtraction and Dispersive Kits User Guide
Extraction and Dispersive Kits User Guide QuEChERS Kits Selection Chart... p. 3 AOAC 2007.01 Method Protocol... p. 4 EN I5662 Method Protocol... p. 5 Original Non-Buffered Protocol... p. 6 Ordering Information...
More informationCLARICEP FLASH. Irregular & Spherical Silica Columns. Consistent High Performance. Wide Range of Selectivities. High Pressure Tolerance
CLARICEP FLASH Irregular & Spherical Silica Columns Consistent High Performance Wide Range of Selectivities High Pressure Tolerance Excellent Availability High Quality Switch to CLARICEP for IMMEDIATE
More informationLet s Clear the Air...
NEW LC SOLVENT SAFETY PRODUCTS Let s Clear the Air... Protect Your Lab Protect Your Results Reduce Costs LC SOLVENT SAFETY PRODUCTS Time to Make a Change The SecurityCAP mobile phase and solvent waste
More informationEffective Scaling of Preparative Separations Using Axial Compression Columns
Effective Scaling of Preparative Separations Using Axial Compression Columns Peter Rahn, Gareth Friedlander, Graham Osborn, and Emmet Welch Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA Introduction
More information* Strata-X is patented by Phenomenex, Inc. Oasis is a registered trademark of Waters Corporation. Phenomenex is not affiliated with Waters
* Strata-X is patented by Phenomenex, Inc. asis is a registered trademark of Waters Corporation. Phenomenex is not affiliated with Waters Corporation. 2010 Phenomenex, Inc. All rights reserved. Fact: *Strata
More informationBIOANALYSIS CONSUMABLE SOLUTIONS. Sample Preparation and Liquid Chromatography Solutions for Quantitative BIOANALYSIS
BIOANALYSIS CONSUMABLE SOLUTIONS Sample Preparation and Liquid Chromatography Solutions for Quantitative BIOANALYSIS At Waters, we understand the unique challenges faced by the bioanalytical community,
More informationNew Core-Shell Technology
New Core-Shell Technology Fortis Speedcore columns are the very latest in core-shell technology. Incorporating our optimised bonding and packing practices with a core-shell particle provides the analyst
More informationAPPLICATIONS TN Automated Method Development of Oligonucleotide in Tissues Using Clarity OTX 96-Well Plate and High Resolution Mass Spectrometry
APPLICATIONS Automated Method Development of Oligonucleotide in Tissues Using Clarity OTX 96-Well Plate and High Resolution Mass Spectrometry Xianrong (Jenny) Wei 1, David M. Good 2, Sean Orlowicz 1, Michael
More informationOn-Line. User s Guide SPE CARTRIDGES. for Rapid Cleanup and Extraction of Analytes
On-Line SPE CARTRIDGES for Rapid Cleanup and Extraction of Analytes User s Guide What is the strata-x on-line SPE cartridge? The strata-x on-line cartridge combines the revolutionary benefits of the patent
More informationULTIMATE PRE-PACKED PREPARATIVE COLUMN GUARANTEED! NEW PHASES! THE FOR HPLC AND SFC. Axia PREP LC columns offer:
THE ULTIMATE PRE-PACKED PREPARATIVE CLUMN FR HPLC AND SFC GUARANTEED! Axia PREP LC columns offer: Increased Performance Groundbreaking Lifetimes ptimized Loadability Increased Reproducibility NEW PHASES!
More informationBiotherapeutic Method Development Guide
Biotherapeutic Method Development Guide HALO BIOCLASS 1000 Å PROTEIN SELECTIVITY KIT Fused-Core Particle Technology BIOCLASS Strategy for Optimizing Protein Separations Using Reversed-phase Liquid Chromatography
More informationAgilent Prep LC Columns for Small Molecules and Biomolecules MAINTAIN RAPID, RELIABLE SEPARATIONS AS YOU SCALE-UP
Agilent Prep LC Columns for Small Molecules and Biomolecules MAINTAIN RAPID, RELIABLE SEPARATIONS AS YOU SCALE-UP AGILENT PREP COLUMNS FOR HPLC FLEXIBLE, COST-EFFECTIVE OPTIONS FOR SCALING AND PREPARATIVE
More informationBiotherapeutic Method Development Guide
Biotherapeutic Method Development Guide HALO BIOCLASS 1000 Å PROTEIN SELECTIVITY KIT Fused-Core Particle Technology BIOCLASS Strategy for Optimizing Protein Separations Using Reversed-phase Liquid Chromatography
More informationBivalirudin Purification:
Bivalirudin Purification: Sorbent Screening and Overload Experiments Marc Jacob, Joshua Heng, and Tivadar Farkas Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA PO94190412_W Abstract In this
More informationImproved Peptide Maps Using Core-Shell Media: Explaining Better Biopharmaceutical Applications With Kinetex C18 Columns
Improved Peptide Maps Using Core-Shell Media: Explaining Better Biopharmaceutical Applications With Kinetex C18 Columns Michael McGinley, Jeff Layne, and Vita Knudson Phenomenex, Inc., 411 Madrid Ave.,Torrance,
More informationKromasil Eternity Designed for long life
1 Kromasil Eternity Designed for long life 2 Outline of the presentation Introduction of the Kromasil Eternity p Modifying the silica p Functionalizing the silica: C18 and PhenylHexyl Product characteristics/assortment
More informationLiner Style* Function Advantages Disadvantages Recommended For Straight Low surface area for less activity Least expensive Low activity
LINER SELECTION GUIDE Liner Style* Function Advantages Disadvantages Recommended For Straight Low surface area for less activity Simple to use Least expensive Low activity Possible inlet discrimination
More information2015 CATALOG. Discover the Advantages of HALO and HALO BioClass Fused-Core Columns
01 CATALOG Discover the Advantages of HALO and HALO BioClass Fused-Core Columns Table of Contents Key Advantages of HALO Fused-Core Columns 3 Selecting the Appropriate Pore Size BIOCLASS COLUMNS 4 HALO
More informationFast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover
columns ProSwift Reversed-Phase Monolith Columns for Protein Analysis ProSwift reversed-phase columns use a unique monolith technology for fast, high-resolution HPLC and LC/MS separations of proteins.
More informationImproving Retention Time Precision and Chromatography of Early Eluting Peptides with Acetonitrile/Water Blends as Solvent B
Improving Retention Time Precision and Chromatography of Early Eluting Peptides with Acetonitrile/Water Blends as Solvent B Stephan Meding, Aran Paulus, and Remco Swart ¹Thermo Fisher Scientific, Germering,
More informationAgilent SD-1 Purification System. Purify your way SD-1
Agilent SD-1 Purification System Purify your way SD-1 AGILENT SD-1 PURIFICATION SYSTEM PURIFY YOUR WAY WITH HIGH QUALITY SEPARATIONS AT ANY SCALE The Agilent SD-1 Purification System achieves better gradient
More informationAgilent 218 Purification System. Purify your way
Agilent 218 Purification System Purify your way 218 AGILENT 218 PURIFICATION SYSTEM PURIFY YOUR WAY WITH A FLEXIBLE SYSTEM WITHIN REACH OF YOUR BUDGET The Agilent 218 Purification System has the flexibility
More informationLux hiral olumns Dependable. Scalable. Affordable. Stable in ormal Phase (P), Polar rganic (P), Reversed Phase (RP), and Supercritical Fluid hromatogr
Dependable. Scalable. Affordable. Affordable hiral olumns, Brilliant Separation Power Guaranteed alternatives to IRALEL and IRALPAK columns EW Amylose-- Lux Amylose- Guaranteed Alternative to IRALPAK AD
More informationTake A Deep Breath. Set down that multi-channel pipette. And let us take you to a new state of biologics Zen.
Take A Deep Breath Set down that multi-channel pipette And let us take you to a new state of biologics Zen Peptide Mapping Peptide Quantitation Intact Mass Intact and Fragment Analysis Aggregate Analysis
More informationSwitch to BioSep GFC Columns for Protein Analysis
Switch to BioSep GFC Columns for Protein Analysis Expanded Resolution Windows vs. Other GFC Columns Batch-to-Batch Reproducibility Highly Inert Material for Better Recovery and Quantitation Designed for
More informationNano LC at 20 nl/min Made Easy: A Splitless Pump Combined with Fingertight UHPLC Nano Column to Boost LC-MS Sensitivity in Proteomics
Nano LC at 20 nl/min Made Easy: A Splitless Pump Combined with Fingertight UHPLC Nano Column to Boost LC-MS Sensitivity in Proteomics Rieux L 1., De Pra M 1., Köcher T 2., Mechtler K 2., Swart R 1 1 Thermo
More informationThe Ultimate Pre-Packed Preparative Column for HPLC and SFC GUARANTEED!
The Ultimate Pre-Packed Preparative Column for PLC and SFC GUARANTEED! Axia PREP LC columns offer: Increased Performance Groundbreaking Lifetimes ptimized Loadability Increased Reproducibility The Ultimate
More information[ Care and Use Manual ] Waters AccellPlus QMA and CM Bulk Media. I. calculating bulk media needs. II. packed column use. IIi.
[ Care and Use Manual ] Waters AccellPlus QMA and CM Bulk Media I. calculating bulk media needs II. packed column use a. Slurry Column Packing b. Dry Column Packing c. Column Equilibration d. Packed Column
More informationGC Columns GC COLUMN INSTALLATION GUIDE.
GC Columns GC COLUMN INSTALLATION GUIDE www.phenomenex.com/gc TROUBLESHOOTING TOOLS Flow meter Leak detector New syringe Column performance test sample Methane or other non-retained compound Reference
More informationSize Exclusion BioHPLC columns Ion Exchange BioHPLC columns
Confidently separate and characterize bio-molecules with Agilent BioHPLC columns Size Exclusion BioHPLC columns Ion Exchange BioHPLC columns "It's a struggle to isolate and identify charge variants of
More informationcolumns PepSwift and ProSwift Capillary Monolithic Reversed-Phase Columns
columns PepSwift and ProSwift Capillary Monolithic Reversed-Phase Columns PepSwift and ProSwift monolithic columns are specially designed for high-resolution LC/MS analysis in protein identification, biomarker
More information4/4/2013. BioHPLC columns. Paul Dinsmoor Biocolumn Technical Specialist. April 23-25, Size Exclusion BioHPLC Columns
BioHPLC columns Paul Dinsmoor Biocolumn Technical Specialist April 23-25, 2013 Size Exclusion BioHPLC Columns 1 NEW Size Exclusion Columns 5 m Particle 100Å, 150Å, 300Å, 500Å, 1000Å, 2000Å pore sizes High
More informationZORBAX StableBond HPLC Columns
ZORBAX HPLC Columns Longest column lifetime and best reproducibility for low ph separations down to ph 1 Patented stable column chemistry allows use at high temperature and low ph without degradation Six
More informationEvaluation of Sub-2µm Zirconia-PBD Particles for Multi-Modal UHPLC
Evaluation of Sub-2µm Zirconia-PBD Particles for Multi-Modal UHPLC Dan Nowlan, B. Yan, C. V. McNeff and R. A. Henry ZirChrom Separations, Inc., 617 Pierce St., Anoka, MN 55303 Horvath 2009 1 Introduction
More informationColumns for Biomolecules BioLC Column Lines
Columns for Biomolecules BioLC Column Lines Monoclonal Antibodies Glycans GlycanPac Nucleic Acids DNAPac Protein A Accucore Amide-HILIC DNAPac PA1 SEC-1 GlycanPac AXH-1 DNAPac PA2 SCX-1 GlycanPac AXR-1
More informationAccucore. Ultimate Core Performance LC Column Technology to Maximize Your Investment. Dave Jarzinski. October 2011
Accucore Ultimate Core Performance LC Column Technology to Maximize Your Investment Dave Jarzinski Thermo Fisher Scientific Account Manager Greater Boston/Cambridge & North Phone: 978-408-1576 Email: dave.jarzinski@thermofisher.com
More informationRAM DIRECT INJECTION (RESTRICTED ACCESS MEDIA)
RAM CHROMATOGRAPHY RAM DIRECT INJECTION (RESTRICTED ACCESS MEDIA) A Tool for the Separation of Small Molecules in the Presence of Large Biomolecules Conventional Sample Precipitate proteins Centrifuge
More informationBIOANALYTICAL STRATEGY FOR IN VITRO METABOLITE SCREENING WITH EXACT MASS USING THE Q-Tof micro. Jose M. Castro-Perez 1, Carina Leandersson 2
In metabolism studies, it is vital to understand how a particular drug is absorbed, distributed, metabolised, and eliminated by the body. Metabolite identification is a very important part of the drug
More informationA Brief Overview of HPLC & UHPLC Method Development and Optimization. Dr. Chris Message UHPLC/HPLC Product Specialist Phenomenex
A Brief Overview of HPLC & UHPLC Method Development and Optimization Dr. Chris Message UHPLC/HPLC Product Specialist Phenomenex Poll Question 1 What learning objectives most attracted you to this webinar?
More informationFood and Environmental Analysis. A Quicker. and Easier. Sample Preparation Choice.
A Quicker and Easier Sample Preparation Choice Food and Environmental Analysis /roq QuEChERS 1 What is QuEChERS? QuEChERS is a Sample Preparation Technique for: Complex sample matrices Wide range of compounds
More informationfor water and beverage analysis
Thermo Scientific EQuan MAX Plus Systems Automated, high-throughput LC-MS solutions for water and beverage analysis Pesticides Pharmaceuticals Personal care products Endocrine disruptors Perfluorinated
More informationCombining High Temperature and Small Particles: The Advantages of Zirconia
Combining High Temperature and Small Particles: The Advantages of Zirconia EAS 9 Dan owlan 1, Bingwen Yan 1, Clayton V. Mceff 1, R.A. Henry 1 ZirChrom Separations, Inc. 617 Pierce St., Anoka, M 5533 Independent
More informationReversed Phase Solutions for the Analysis of Proteins, Peptides, and Oligonucleotides
Reversed Phase Solutions for the Analysis of Proteins, Peptides, and Oligonucleotides The line, which includes and Proteo, offers various reversed phase solutions for biochromatography. With these two
More informationDiscovery BIO Wide Pore
Discovery BIO Wide Pore Solutions to Protein and Peptide Separation Challenges T403118 2 Agenda: What is Discovery BIO Wide Pore Physical characteristics Why we developed it and for whom Performance demonstrations
More informationMartin Gilar Waters Corporation, Milford, MA, U.S. Origins of synthetic oligonucleotides impurities. Lab-scale isolation options
LIGNUCLETIDE SEPARATIN TECHNLGY: SYNTHESIS CHALLENGES AND HPLC ISLATIN PTINS Martin Gilar Waters Corporation, Milford, MA, U.S. INTRDUCTIN rigins of synthetic oligonucleotides impurities Use of synthetic
More informationThe Ultimate Pre-Packed Preparative Column for HPLC and SFC
The Ultimate Pre-Packed Preparative Column for PLC and SFC GUARANTEED! Axia PREP LC columns offer: Increased Performance Groundbreaking Lifetimes Optimized Loadability Increased Reproducibility The Ultimate
More informationADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS
Agilent AdvanceBio Columns ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS with Agilent ZORBAX RRHD 3Å 1.8 µm columns ns Rapid resolution high definition columns for UHPLC protein and peptide separations
More informationA method to pack Agilent Prep C18 Media on Load & Lock Column
A method to pack Agilent Prep C18 Media on Load & Lock Column Application Note Author Liqin Chen, Rong An Life Science and Chemical Analysis Agilent Technologies Shanghai, China Abstract The successful
More informationA Fast and Effective Approach for Running EPA Method 539: Determination of Hormones in Drinking Water using SPE and LC/MS/MS
A Fast and Effective Approach for Running EPA Method 539: Determination of Hormones in Drinking Water using SPE and LC/MS/MS Xianrong (Jenny) Wei 1, Matthew Trass 1, Ali Haghani 2, Andy Eaton 2 1 Phenomenex,
More informationNew Stable Chemically Bonded Carbon Stationary Phases for HPLC
New Stable Chemically Bonded Carbon Stationary Phases for HPLC Angelos Kyrlidis, Lynn Toomey, and Elena Khmelnitskaia, Cabot Corporation Dwight Stoll, Clayton V. McNeff, and Peter W. Carr ZirChrom Separations,
More informationPreparative, Pilot & Process Columns
Preparative, Pilot & Process Columns 321 Preparative, Pilot & Process Columns Contents Prep Columns... 322-323 Dynamic Axial Compression Columns (DAC)... 324-325 Pilot Columns... 326-327 Chromatography
More informationEVOLUTE ABN SPE Columns for Solid Phase Extraction of Environmental Samples
TN136 EVOLUTE ABN SPE Columns for Solid Phase Extraction of Environmental Samples This Chemistry Data Sheet provides guidelines for the simultaneous extraction of acidic, basic and neutral compounds from
More informationSOURCE 15HIC. GE Healthcare. SOURCE 15ETH, SOURCE 15ISO, SOURCE 15PHE, SOURCE 15PHE 4.6/100 PE (Tricorn ), Characteristics
GE Healthcare Data file 18-1128-86 AC High-performance hydrophobic interaction chromatography SOURCE 15HIC SOURCE 15ETH, SOURCE 15ISO, SOURCE 15PHE, SOURCE 15PHE 4.6/100 PE (Tricorn ), Resource ETH, Resource
More informationAgilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility
Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility Technical Overview Introduction Agilent AdvanceBio SEC columns are a new family of size exclusion chromatography (SEC) columns
More informationReversed-Phase HPLC Columns
Reversed-Phase HPLC Columns Hamilton reversed-phase HPLC columns combine the best characteristics of silica-based and polymeric columns to arrive at a product that is highly inert and long-lasting. Hamilton
More informationRAM Direct Injection. (Restricted Access Media) A Tool for the Separation of Small Molecules in the Presence of Large Biomolecules
RAM Direct Injection (Restricted Access Media) A Tool for the Separation of Small Molecules in the Presence of Large Biomolecules HPLC analysis of small molecules contained within a protein matrix can
More informationIntroducition of a new product from Inertsil Series
Introducition of a new product from Inertsil Series is a C8 column developed focusing on superb inertness to basic, acidic, neutral and chelating compounds, which can virtually provide perfect peak shapes
More informationNuvia HR-S Strong Cation Exchange Media Instruction Manual
Nuvia HR-S Strong Cation Exchange Media Instruction Manual Catalog numbers 156-0511 156-0513 156-0515 156-0517 Please read these instructions before you use Nuvia HR-S cation exchange media. If you have
More informationMethod Optimisation in Bottom-Up Analysis of Proteins
Method Optimisation in Bottom-Up Analysis of Proteins M. Styles, 1 D. Smith, 2 J. Griffiths, 2 L. Pereira, 3 T. Edge 3 1 University of Manchester, UK; 2 Patterson Institute, Manchester, UK; 3 Thermo Fisher
More informationorder:
HPLC Guard Column Cartridges (Prepacked) ES Industries guard column cartridges offer excellent protection for your analytical column. Adding a guard column to your HPLC system extends the life of your
More informationBÜCHI Labortechnik AG
BÜCHI Labortechnik AG Purification BUCHI Chromatography History 1977: BUCHI Fraction Collector 1978: 1 st preparative chromatography system 2008: automated chromatography system 2014: automated high performance
More informationTake A Deep Breath. And let us take you to a new state of biologics Zen. Peptide Mapping (RP) Aggregate Analysis (SEC)
Take A Deep Breath And let us take you to a new state of biologics Zen Peptide Mapping (RP) Aggregate Analysis (SEC) NEW Charge Variant Analysis (IEX) Glycan Analysis (HILIC) Peptide Quantitation (RP)
More informationDevelopment of Analysis Methods for Therapeutic Monoclonal Antibodies Using Innovative Superficially Porous Particle Biocolumns
Development of Analysis Methods for Therapeutic Monoclonal Antibodies Using Innovative Superficially Porous Particle Biocolumns Anne Blackwell Bio Columns Product Support Scientist Suresh Babu Senior Application
More informationBioHPLC columns. Tim Rice Biocolumn Technical Specialist
BioHPLC columns Tim Rice Biocolumn Technical Specialist AU Typical Application Areas Size Exclusion: Aggregation Analysis Ion Exchange: Charge Isoform Analysis 0.035 Monomer 0.030 0.025 0.020 0.015 Dimer
More informationThermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance
Thermo Scientific EASY-nLC 1200 System Leading in simplicity and performance Peak performance made EASY Effortless ultra high performance for everybody A straightforward LC-MS solution Optimized and integrated
More informationof peptide mapping chemistries, 130Å or 300Å with tunable UV, photodiode array, or mass spectrometry
UPLC PEPTIDE ANALYSIS SOLUTION UPLC Peptide Analysis Solution: n ACQUITY UPLC System n Peptide Separation Technology chemistries, 130Å or 300Å n Flexible detection capabilities, with tunable UV, photodiode
More informationADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS
Agilent AdvanceBio Columns ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS with Agilent ZORBAX RRHD 3Å 1.8 µm columns ns Rapid resolution high definition columns for UHPLC protein and peptide separations
More informationProtein-Pak Hi Res HIC Column and HIC Protein Standard
Protein-Pak Hi Res HIC Column and HIC Protein Standard CONTENTS I. INTRODUCTION II. a. Mobile Phase b. Flow Direction CONNECTING COLUMN TO LC SYSTEM I. INTRODUCTION This offering contains non-porous, polymethacrylate-based
More informationGet Your Fill. A full line of empty chromatography columns and accessories. Protein Purification
Get Your Fill. A full line of empty chromatography and accessories. Protein Purification Bio-Rad s Empty Line Is Packed With Options From low-pressure chromatography to high-resolution separations, we
More informationErstellt mit einer Testversion von PDF Annotator - FLUIDIC & OPTICAL PRODUCTS AND INFORMATION
Erstellt mit einer Testversion von PDF Annotator - www.pdfannotator.de FLUIDIC & OPTICAL PRODUCTS AND INFORMATION 156 Column Hardware We offer an extensive line of HPLC and UHPLC Column Hardware that has
More informationQuantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS
Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 12 Series RRLC and 641B Triple Quadrupole LC/MS Application Note Manufacturing Process Development Author Siji Joseph Agilent
More informationNew Roc LC Columns The Reliable Cornerstone for Your LC Lab
Product Launch Training New Roc LC Columns The Reliable Cornerstone for Your LC Lab Paul Connolly Business Manager Liquid Chromatography Objectives What is Roc The competition Where to position Roc Product
More informationOnline LC Sample Preparation with BioTrap 500 C18
Online LC Sample Preparation with BioTrap 500 C18 Jörgen Hermansson Anders Grahn Inger Hermansson ChromTech AB Stockholm, Sweden Phone: 08-464-8020 Fax: 08-464-7020 E-mail: ct@chromtech.se http://www.chromtech.
More informationAPPLICATIONS TN Detection and Identification of Gulf Oil Dispersants (COREXIT 9527 and 9500) by GC/MS and LC/MS/MS
Detection and Identification of Gulf Oil Dispersants (COREXIT 9527 and 9500) by GC/MS and LC/MS/MS Sky Countryman, Matthew Trass, Seyed Sadjadi, and Jeff Layne Phenomenex, Inc., 411 Madrid Ave., Torrance,
More informationComparison Guide. Comparison Data on Commonly Used C18 Phases TO C18 REVERSED P HASE HPLC COLUMNS. Stationary Phase Specifications
Comparison Guide TO C8 REVERSED P HASE HPLC COLUMNS Comparison Data on Commonly Used C8 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Comparison of Column
More informationAgilent 1290 Infinity Binary LC System with ISET - Emulation of the Waters Alliance 2695 LC system analyzing b-blockers
Agilent 1290 Infinity Binary LC System with ISET - Emulation of the Waters Alliance 2695 LC system analyzing b-blockers Application Note mau Author A. G. Huesgen Agilent Technologies, Inc. Waldbronn, Germany
More informationPuzzled About LCMS? Sample. Sensitivity in Mass Spec Analysis. Prep. Adapting LC-UV. Optimizing and Maintaining Your Mass Spec LCMS
Puzzled About LCMS? Sensitivity in Mass Spec Analysis Sample Prep Adapting LC-UV Optimizing and Maintaining Your Mass Spec To LCMS Paul Altiero Alex Ucci Applications Phone Support Chemistry and Supplies
More informationPLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC
PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC Analysis of Intact and Fragmented mabs and ADC Application Note Biotherapeutics and Biologics Author Suresh Babu C.V. Agilent
More informationChromatography Column Performance and Data Analysis Success Guide. Hints and Tips for Better Purifications
Chromatography Column Performance and Data Analysis Success Guide Hints and Tips for Better Purifications This Chromatography Success Guide provides practical advice on preparative chromatography and protein
More informationfor Acclaim Carbamate Column
for Acclaim Carbamate Column Product Manual for Acclaim Carbamate Page 1 of 13 Product Manual for Acclaim Carbamate Analytical Columns 5 µm, 4.6 x 250 mm, P/N 072924 3 µm, 4.6 x 150 mm, P/N 072925 3 µm,
More informationHigh Throughput Sub-4 Minute Separation of Antibodies using Size Exclusion Chromatography
High Throughput Sub-4 Minute Separation of Antibodies using Size Exclusion Chromatography TSKgel APPLICATION NOTE Introduction Gel Filtration Chromatography (GFC) is a powerful analytical tool in the separation
More informationEVOLUTE ABN FOR EXTRACTION OF DRUGS FROM BIOLOGICAL FLUIDS
Technical ote 3 EVLUTE AB FR EXTRACTI F DRUGS FRM BILGICAL FLUIDS EVLUTE Sample Preparation Products are a new generation of advanced polymeric solid phase extraction sorbents for the high throughput extraction
More informationBioSolutions for Synthetic DNA/RNA
DNA/RNA PURIFICATION & characterization CLARITY BIOSOLUTIONS Clarity U.S. Patent No. 7, 119, 14 Optimized Oligo Purification and Analysis RPC, HPLC, prep LC, desalting, and extraction solutions DNA, RNA/RNAi,
More informationR R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013
5-100 Innovation Way Newark, DE 19711, USA Tel:302-3661101 Fax:302-3661151 Website: www.sepax-tech.com Published in November 2013 P/N SECKIT-7830 These Phases are developed based on innovative surface
More informationSSENTIALS RESTEK. Must-Have Solutions for Your Lab Leverage 3-in-1 Technology for Outstanding Inertness Low Bleed High Reproducibility
RESTEK SSENTIALS Must-Have Solutions for Your Lab 2014.2 Leverage 3-in-1 Technology for Outstanding Inertness Low Bleed High Reproducibility ALSO IN THIS ISSUE: Raptor Columns: Biphenyl & ARC-18 Sky Inlet
More informationThermo Scientific MAbPac HIC Columns. Novel Hydrophobic Interaction HPLC Columns. Designed for Monoclonal Antibody Analysis
Thermo Scientific MAbPac HIC Columns Novel Hydrophobic Interaction HPLC Columns Designed for Monoclonal Antibody Analysis Introduction The Thermo Scientific MAbPac HIC column family is designed for separations
More informationCustomized systems to meet your lab s needs
WATERS PURIFICATION SYSTEMS Compound purification and isolation can be more efficient and more productive With Waters systems, purify using multiple detection choices: n Ultraviolet/Visible (UV/Vis) Absorbance
More informationPreparative Purification of Corticosteroids by HPLC; Scalability and Loadability Using Agilent Prep C18 HPLC Columns Application
Preparative Purification of Corticosteroids by PLC; Scalability and Loadability Using Agilent Prep C18 PLC Columns Application Pharmaceuticals Authors Cliff Woodward and Ronald Majors Agilent Technologies,
More informationPhysical Stability of a Silica- Based Size Exclusion Column for Antibody Analysis
Physical Stability of a Silica- Based Size Exclusion Column for Antibody Analysis Atis Chakrabarti* and Roy Eksteen + Tosoh Bioscience LLC, King of Prussia, PA 19406 *Corresponding Author. + Current address:
More informationTemperature and ph Stability of a New High Temperature C18 Polydentate Silica Column
Temperature and ph Stability of a New High Temperature C18 Polydentate lica Column Stephanie J. Marin 1, Brian A. Jones 1 Jody Clark 1, Nathan L. Porter 1 J. Andreas Lippert 2, and Todd M. Johnson 2 1.
More information