Los Angeles Unified School District Belmont Learning Complex Request for Proposal IOR Deficiency Report by Specification Number

Size: px
Start display at page:

Download "Los Angeles Unified School District Belmont Learning Complex Request for Proposal IOR Deficiency Report by Specification Number"

Transcription

1 DISCLAIMER: THE DISTRICT PROVIDES INFORMATION ABOUT THE DOCUMENTS AVAILABLE FOR REVIEW. THIS INFORMATION IS INFORMATIONAL ONLY AND THE DISTRICT DOES NOT WARRANT THAT THE INF COMPLETE OR CURRENT. ALTHOUGH EVERY REASONABLE EFFORT HAS BEEN MADE TO MAKE THE INFORMATION AS COMPLETE AS POSSIBLE, ANYONE OR ANY ENTITY UTILIZING OR ACCESSING THIS INFORMAT PERFORM ITS OWN DUE DILIGENCE AND MAY NOT RELY ON THE SUPPLIED INFORMATION ALONE. Los Angeles Unified School District Belmont Learning Complex Request for Proposal IOR Deficiency Report by Specification Number ID Spec. Section <1> Location Trade Description Drawing # Image # <2> 2427 Academy Houses Doors, Frames and Finish Hardware Incorrect door installed in bathrooms, window panels in doors. AB P jpg 890 Academy Houses Drywall/EIFS/SOFP Top of wall above door has not been fire proofed. P jpg 3287 Academy Houses Drywall/EIFS/SOFP Gypsum board openning for electrical receptical exceeds 1/8 max gap on South wall next AB P jpg entrance to room Academy Houses Drywall/EIFS/SOFP Insulation not installed at exterior walls. AB P jpg 5007 Academy Houses Drywall/EIFS/SOFP From elevation to top of parapet EIFS not installed, wall has Hip wrap installed. AB P jpg 2380 Academy Houses Drywall/EIFS/SOFP Plaster stuck to interior floors creating irregular concrete surface, total of 7 locations. AB Size varies Academy Houses Drywall/EIFS/SOFP 4 Holes in fire rated wall require patching or fire stop. East wall at North end. AB P jpg 899 Academy Houses Drywall/EIFS/SOFP Top of walls have not been fire proofed at N line corridor. AB P jpg 2401 Academy Houses Electrical (School) 8 Conduits thru rated wall are not fire stopped. AB P jpg 2437 Academy Houses Electrical (School) Conductors missing in boxes. AB P jpg 2218 Academy Houses Electrical (School) Boxes and conduit have been supported from light gage at roof deck. AB P jpg 2008 Academy Houses Electrical (School) Fire alarm conduit not identified. AB P jpg 2091 Academy Houses Electrical (School) Min. power packs not connected to power in rooms noted. AB P jpg 3087 Academy Houses Electrical (School) Conduit not properly supported. AB3-1.0 P jpg 3084 Academy Houses Electrical (School) Tele data boxes are not identified in the ceiling and the 1" conduit at the 8 x 8 box is not AB3-1.0 P jpg properly supported Academy Houses Electrical (School) Fire rated plywood has not been installed in all electrical rooms as required by plans. AB Academy Houses Electrical (School) 3-4S boxes conductors not pulled, 2-4S boxes conductor pulled, not landed, cover plates AB P jpg not provided Academy Houses Electrical (School) 8 Gray tel-com boxes do not have cables and have not been identified. AB P jpg 878 Academy Houses Electrical (School) Conduit run in contact with rigid duct. Felt pads are required at points of contact. AB P jpg 732 Academy Houses Electrical (School) 3 Gray telcom boxes A) 1 wire pulled no cover no ID B) Cable pull not landed no ID on AB P jpg box C) Box with no cable pulled no ID. 806 Academy Houses Electrical (School) 2-4S boxes over door 302, conductor not pulled and coax cable pulled, no cover plates AB P jpg provided Academy Houses Fire Protection Fire sprinkler main for roof monitor runs through the electrical room in violation of AB P jpg electrical code. 323 Academy Houses Flashing and Sheet Metal Incomplete roof area. Photo taken after temporary roof cover installed. Area of A.H. #2 AB P jpg Cooling tower area. 795 Academy Houses HVAC and Temperature Control Systems 6 by 6 exhaust air register not installed. AB P jpg 907 Academy Houses Plumbing Clamps are loose on acid waste line and felt has not been used at clamps. Also identify P jpg acid waste line. 884 Academy Houses Plumbing 8 Vent 5 gas lines are in contact with duct. Felt pads required at point of contact. AB P jpg 612 Academy Houses Plumbing All control valves and pipe to be ID'ed. AB P jpg 847 Academy Houses Plumbing Lower access panel door not installed. Gas and water shut off valves inaccessible. AB P jpg 629 Academy Houses Plumbing Gas line installed on trapeze for electrical conduit in violation of code. Gas pipe must AB P jpg have its own hangers. 734 Academy Houses Plumbing Access door for water hammer arrestor not installed. AB P jpg 9019 Administration Drywall/EIFS/SOFP Parapet walls North and West elevation have not been installed. Ref. drawings 1-2-AE- 3.01, 3-AE-3.02, 1-AE-2.01 AE-1.03 P jpg Print Date: 7/3/01 Page 1 of 154

2 DISCLAIMER: THE DISTRICT PROVIDES INFORMATION ABOUT THE DOCUMENTS AVAILABLE FOR REVIEW. THIS INFORMATION IS INFORMATIONAL ONLY AND THE DISTRICT DOES NOT WARRANT THAT THE INF COMPLETE OR CURRENT. ALTHOUGH EVERY REASONABLE EFFORT HAS BEEN MADE TO MAKE THE INFORMATION AS COMPLETE AS POSSIBLE, ANYONE OR ANY ENTITY UTILIZING OR ACCESSING THIS INFORMAT PERFORM ITS OWN DUE DILIGENCE AND MAY NOT RELY ON THE SUPPLIED INFORMATION ALONE. Los Angeles Unified School District Belmont Learning Complex Request for Proposal IOR Deficiency Report by Specification Number ID Spec. Section <1> Location Trade Description Drawing # Image # <2> 9020 Administration Drywall/EIFS/SOFP Refer to drawings AE-3.02 detail 2. Parapet walls on east elevation at the radius have AE-1.03 P jpg not been installed Administration Electrical (School) Electrical sub panel with no conductors, no pull strings, no internal hardware. Column AE-1.03 P jpg line 4-A Administration Flashing and Sheet Metal Screws on sheet metal coping not sealed correctly. (Not caulked or no-neoprene washers AE-1.03 P jpg used) Administration General Contracting Cap flashing galvanized tube steel, plywood, roofing material, left on roof. AE-1.03 P jpg 233 Parking Garage Drywall/EIFS/SOFP At South gypsum fire rated wall - Two holes 4" and 7'8" from deck slab AA 1.03 P jpg correction required. 335 Parking Garage Drywall/EIFS/SOFP At South gypsum fire rated wall - Two holes 4" and 7'8" from deck slab AA 1.03 P jpg correction required. 366 Parking Garage Drywall/EIFS/SOFP South wall not completed at EastWest corner. AA 1.09 P jpg 18 Parking Garage Drywall/EIFS/SOFP Wrong size drilled anchors in wall. Correct size not installed. AA Parking Garage Drywall/EIFS/SOFP Shot pins spaced further apart that allowed per detail above. AA-1.03 P jpg 136 Parking Garage Electrical (Parking) Link seals not installed at exterior walls. EA107 P jpg 11 Parking Garage Electrical (School) Box penetration on opposite sides of wall 3" apart need fire safeing. Closer than 24" AA-1.02 P jpg apart. 665 Parking Garage Fire Protection Sprinkler line drops under HVAC duct not properly supported. AA 1.01 AA P jpg Parking Garage Fire Protection 5 Sprinkler 11' drops: Requires support at sprinkler head. AA 1.03 P jpg 262 Parking Garage Fire Protection Fire sprinkler wall penetration not sleeved or fire stop caulked. AA 1.05 P jpg 9 Parking Garage HVAC and Temperature Control Systems Anchor bolts at bracing straps need torque testing. SA Parking Garage Hydraulic Elevators All drilled anchors shall be tension or torque tested. AA-1.04 P jpg 2506 Site-Wide Concrete/Masonry/Reinforcing Steel (Site From station to station concrete starter wall snap-tie holes have not C-1.12 P jpg Retaining Walls) been purged Site-Wide Roofing and Waterproofing From station to station concrete starter wall and masonry retaining wall C-1.12 P jpg has not been water proofed. 562 Triple Gym General Contracting Remove combustible debris between AH # 4 and TGYM at line T&T1 from 1.9 to 7. AC-1.02 P jpg 468 Triple Gym HVAC and Temperature Control Systems Open conduit sleeves in CMU walls required to be firestopped. See note on G-1. AC 1.02 P jpg 1435 Triple Gym Miscellaneous Iron and Steel Stairs Tube steel header for doors not anchored at masonry. AC1.01 P jpg 430 Triple Gym Plumbing Protection shields required at clevis hangers on foam insulated condensate line. AC 1.02 P jpg 576 Triple Gym Plumbing Patch pipe hanger at beams with fire proofing. AC-1.02 P jpg Parking Garage Plumbing A 6" hole has been core drilled thru the ramp slab for a 4" vent line. The cored hole has PA-1.02 cut thru 2 #9 rebar. One looking east and west and one looking north and south. Patometer testing was not asked for Academy Houses Electrical (School) Drilled anchors have not been tested. AB P jpg Academy Houses Electrical (School) Drilled anchors have not been tested in room. AB P jpg Academy Houses Electrical (School) Drilled anchors have not been tested in all rooms noted. AB P jpg Academy Houses Electrical (School) Anchorage for hanger rod for light fixtures and conduit and conduit rack support have AB P jpg not been tested Academy Houses Electrical (School) Anchorage for main breaker, AC4MDL, panels and distributor transformer have not been tested. AB P jpg Print Date: 7/3/01 Page 2 of 154

3 DISCLAIMER: THE DISTRICT PROVIDES INFORMATION ABOUT THE DOCUMENTS AVAILABLE FOR REVIEW. THIS INFORMATION IS INFORMATIONAL ONLY AND THE DISTRICT DOES NOT WARRANT THAT THE INF COMPLETE OR CURRENT. ALTHOUGH EVERY REASONABLE EFFORT HAS BEEN MADE TO MAKE THE INFORMATION AS COMPLETE AS POSSIBLE, ANYONE OR ANY ENTITY UTILIZING OR ACCESSING THIS INFORMAT PERFORM ITS OWN DUE DILIGENCE AND MAY NOT RELY ON THE SUPPLIED INFORMATION ALONE. Los Angeles Unified School District Belmont Learning Complex Request for Proposal IOR Deficiency Report by Specification Number ID Spec. Section <1> Location Trade Description Drawing # Image # <2> Academy Houses Electrical (School) Drilled anchors for anchoring main gear have not been tested. AB P jpg Academy Houses General Contracting Misc. construction materials stored throughout level 1. AB P jpg Academy Houses General Contracting Trash at inside of wall void spaces and stud wall bottom tracks, typical. AB P jpg Academy Houses General Contracting Trash at inside of wall void spaces and stud wall bottom tracks, typical. AB P jpg Academy Houses General Contracting Trash at inside of wall void spaces and stud wall bottom tracks, typical. AB P jpg Parking Garage Electrical (School) All anchor bolts shall be tension or torque tested per above code. AA Parking Garage HVAC and Temperature Control Systems All drilled anchors shall be tension or torque tested. AA-1.02 P jpg Parking Garage Hydraulic Elevators Drilled anchors for fan not torque tested. AA-1.07 P jpg Parking Garage Miscellaneous Iron and Steel Stairs 3/4 Wedge anchors for stair & stair landings supports. AA P jpg Parking Garage Plumbing All drilled anchors shall be tension or torque tested per code above. PA Triple Gym General Contracting Misc. trash inc. lumber and pallets. AC1.01 P jpg Triple Gym General Contracting Top of footing needs to be cleaned, typical. AC1.01 P jpg Triple Gym Plumbing Anchorage for plumbing lines supported to North and South CMU walls require testing AC-1.02 P jpg for shear Academy Houses Electrical (School) No seismic sway bracing provided for busway supports, conduit runs and unistrut AB P jpg supports in electrical room Site-Wide Chain Link Fence and Gates From station 4+96 to fence on top of masonry wall not installed and no cap P jpg block Site-Wide Chain Link Fence and Gates From station to fencing on top of concrete wall not installed. C-1.13 P jpg Parking Garage Cast-in-Place Concrete (Parking) 1) Remove snap ties left at slab ceiling 2) Where concrete column abutts horizontal AA 1.01 P jpg beam cold joint / rock pocket exposed to surface. Correction required. 3) Patch West concrete wall Academy Houses Structural Steel - Detailing Rebar for floor slab and masonry wall rusty and damaged. AB P jpg Parking Garage Cast-in-Place Concrete (Parking) Exposed rebar at shear wall under landing across from Door 206. P jpg Parking Garage Cast-in-Place Concrete (Parking) Rebar from shear on W line is exposed at landing. AA 109 P jpg Parking Garage Reinforcing Steel (Parking) Reinforcing bars are badly bent, rusted and not per plan SA101 P jpg Academy Houses Cast-in-Place Concrete (Parking) Hole chipped into slab to relocate conduits into frame wall area at South East corner of AB P jpg room at C Academy Houses Cast-in-Place Concrete (Parking) Concrete surface out of tolerance, uneven concrete floor at doors AB P jpg Academy Houses Cast-in-Place Concrete (Parking) Concrete surface out of tolerance, floor uneven, doors; , about 32' AB P jpg lineal Academy Houses Cast-in-Place Concrete (Parking) Concrete surface out of tolerance, uneven concrete floor at doors; AB P jpg Academy Houses Cast-in-Place Concrete (Parking) Hole in deck where conduit relocated into 3rd floor short wall and full height. Wall on AB P jpg 2nd floor Academy Houses Cast-in-Place Concrete (Parking) 1' x 1' square opening and 4" diameter hole in floor deck. AB P jpg Academy Houses Cast-in-Place Concrete (Parking) Concrete surface out of tolerance, concrete slab near doors (column AB P jpg line G) uneven Academy Houses Cast-in-Place Concrete (Parking) Concrete surface out of tolerance, concrete slab near drinking fountain uneven. AB P jpg Academy Houses Cast-in-Place Concrete (Parking) Concrete surface out of tolerance, concrete joint going East-West near column line F.4, AB P jpg floor uneven Academy Houses Cast-in-Place Concrete (Parking) 3 Holes in slab used for safety post require repair. AB P jpg Academy Houses Cast-in-Place Concrete (Parking) Holes in slab used for safety hand rail post require patching. Total of 3 in rooms noted. AB P jpg Print Date: 7/3/01 Page 3 of 154

4 DISCLAIMER: THE DISTRICT PROVIDES INFORMATION ABOUT THE DOCUMENTS AVAILABLE FOR REVIEW. THIS INFORMATION IS INFORMATIONAL ONLY AND THE DISTRICT DOES NOT WARRANT THAT THE INF COMPLETE OR CURRENT. ALTHOUGH EVERY REASONABLE EFFORT HAS BEEN MADE TO MAKE THE INFORMATION AS COMPLETE AS POSSIBLE, ANYONE OR ANY ENTITY UTILIZING OR ACCESSING THIS INFORMAT PERFORM ITS OWN DUE DILIGENCE AND MAY NOT RELY ON THE SUPPLIED INFORMATION ALONE. Los Angeles Unified School District Belmont Learning Complex Request for Proposal IOR Deficiency Report by Specification Number ID Spec. Section <1> Location Trade Description Drawing # Image # <2> Academy Houses Cast-in-Place Concrete (Parking) Concrete surface out of tolerance, near drinking fountain, column line N.3 1/4" by 2" AB depression 4 feet long Academy Houses Cast-in-Place Concrete (Parking) Concrete surface out of tolerance, near door 121, voids in concrete slab at construction AB P jpg joint Academy Houses Cast-in-Place Concrete (Parking) Concrete surface out of tolerance, concrete slab outside of door , concrete AB P jpg uneven Academy Houses Cast-in-Place Concrete (Parking) Concrete surface out of tolerance, rough concrete floor finish. AB P jpg Academy Houses Cast-in-Place Concrete (Parking) Concrete surface out of tolerance, rough concrete floor finish near column line N.3 and AB Academy Houses Cast-in-Place Concrete (Parking) Concrete surface out of tolerance, near floor door 112 concrete slab uneven. AB P jpg Academy Houses Cast-in-Place Concrete (Parking) Concrete surface out of tolerance, near door 119 along column line S surface uneven and AB P jpg contains voids in concrete Academy Houses Cast-in-Place Concrete (Parking) Concrete surface out of tolerance, East-West joint at slab, column line P.5 surface AB P jpg uneven Academy Houses Cast-in-Place Concrete (Parking) Concrete surface out of tolerance, rough concrete floor finish near column line N and AB between 3.2 to Academy Houses Cast-in-Place Concrete (Parking) Concrete surface out of tolerance, near door 120 and 118, column line S 1/4" deep by 2" AB P jpg wide depression Academy Houses Cast-in-Place Concrete (Parking) Fill holes in deck slab use for safety post at fire rated West wall. AB P jpg Academy Houses Concrete (School) Slab on grade concrete has not been placed. AB P jpg Academy Houses Concrete (School) All rusted and dirty reinforcing to be cleaned before concrete placement. AB P jpg Academy Houses Concrete (School) All bent and broken reinforcing to be corrected. AB P jpg Academy Houses Concrete (School) Foot prints in concrete full width of corridor column 11.5 to AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance. Concrete 2" to high at door 214.1, about 7 foot by 2 AB P jpg foot Academy Houses Concrete (School) Concrete surface out of tolerance at doors; and at AB P jpg drinking fountain column line 12.2, about 65' lineal Academy Houses Concrete (School) Concrete has not been placed for stairs, rebar exposed at floor. AB P jpg Academy Houses Concrete (School) No concrete placed at corridor floor edge stairs; , about 1 foot AB P jpg by 19 feet (6 locations) and steel stair stringer rebar tie-ins about 18" by 6 ' (12 total) Academy Houses Concrete (School) Concrete surface out of tolerance at doors; AB P jpg Academy Houses Concrete (School) No concrete placed at corridor floors, seismic joint, 2' by full width of corridor, column AB P jpg line Academy Houses Concrete (School) Concrete has not been placed at rebar from stair stringers to landing. AB P jpg Academy Houses Concrete (School) Foot prints between column lines 12.5 to 14 and , full width of corridor. AB P jpg Academy Houses Concrete (School) Corridor entry to door concrete not placed, wire mesh and shear studs exposed. AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance on floor slab; full width of corridor from column line AB P jpg 14 to Academy Houses Concrete (School) Concrete surface out of tolerance full width of corridor, column 18.5 to 19. AB P jpg Academy Houses Concrete (School) Roof pads not installed. AB Academy Houses Concrete (School) Roof pads not installed. AB Academy Houses Concrete (School) At elevation foundation has not been placed for masonry veneer. AB P jpg Academy Houses Concrete (School) Concrete foundation is not placed for block veneer 363 elevation. AB P jpg Academy Houses Concrete (School) At elevation foundation has not been placed for masonry veneer. AB P jpg Academy Houses Concrete (School) Cement droppings on floor slab column 5.7 to 6 and C to C.3. AB P jpg Print Date: 7/3/01 Page 4 of 154

5 DISCLAIMER: THE DISTRICT PROVIDES INFORMATION ABOUT THE DOCUMENTS AVAILABLE FOR REVIEW. THIS INFORMATION IS INFORMATIONAL ONLY AND THE DISTRICT DOES NOT WARRANT THAT THE INF COMPLETE OR CURRENT. ALTHOUGH EVERY REASONABLE EFFORT HAS BEEN MADE TO MAKE THE INFORMATION AS COMPLETE AS POSSIBLE, ANYONE OR ANY ENTITY UTILIZING OR ACCESSING THIS INFORMAT PERFORM ITS OWN DUE DILIGENCE AND MAY NOT RELY ON THE SUPPLIED INFORMATION ALONE. Los Angeles Unified School District Belmont Learning Complex Request for Proposal IOR Deficiency Report by Specification Number ID Spec. Section <1> Location Trade Description Drawing # Image # <2> Academy Houses Concrete (School) Concrete surface out of tolerance. Floor drain, concrete placed too high, one location, AB P jpg column line 7.8 and Academy Houses Concrete (School) Concrete surface out of tolerance. Uneven floor at doors 211 and column line 2.7 from AB P jpg E.7 to F Academy Houses Concrete (School) Concrete structural slab does not slope to drain about 10 x 14 foot area expected. AB Academy Houses Concrete (School) Concrete surface out of tolerance. Uneven concrete floor at doors; AB P jpg Academy Houses Concrete (School) Foot prints in concrete at column B to B.5 full width of corridor. AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance. Uneven floor column line 9 to 10 and C to D. AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance. Floor slab rough and slopes about 1", 4 x 5 foot area AB expected Academy Houses Concrete (School) Concrete surface out of tolerance, floor at doors 317 and 318. AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance, floor at door 317. AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance. Uneven floor at doors; , 18' long. AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance floor; uneven column 5.7 to 6.1 full width. No concrete AB P jpg placed at seismic joint, about 1 foot by full width of corridor Academy Houses Concrete (School) Voids in floor column 10 and G, about 6" x 6" each, 2 locations. Concrete droppings AB P jpg between column line 7& Academy Houses Concrete (School) Concrete surface out of tolerance. Uneven floor column line 5.5 to 6, full width of AB P jpg corridor Academy Houses Concrete (School) Concrete surface out of tolerance. Uneven concrete at doors; AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance. Floor drain, concrete placed too high, 2 locations. AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance. Uneven floor at door 311 and column line 2.7 from E.7 AB P jpg to F Academy Houses Concrete (School) Concrete surface out of tolerance: Rough concrete (#1) at doors , rough concrete AB P jpg with voids (#2) column 5.3 to 6.5. Full width of corridor Academy Houses Concrete (School) Concrete surface out of tolerance. Concrete floor rough column line M to L and 2.7 to AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance: Uneven floor (#1) full width, column F to G.3; foor AB P jpg prints (#2) full width, column F to G Academy Houses Concrete (School) Concrete surface out of tolerance, floor rough at door 221. AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance: Uneven floor (#1) width of corridor, column 3 to 5; AB P jpg foot prints (#2) width of corridor, column 4 to Academy Houses Concrete (School) Concrete surface out of tolerance. Floor drain, concrete placed to high, 1 location. AB P jpg Column L.7 and Academy Houses Concrete (School) Concrete surface out of tolerance: Full width and length uneven (#1) and foot prints (#2). AB Academy Houses Concrete (School) Concrete surface out of tolerance: Rough concrete (#1) at doors Also rough concrete near stairs, column 5.5 to 6.5, 2 foot wire Academy Houses Concrete (School) Concrete surface out of tolerance floors, uneven floor (#1) full width of corridor, column 3 to 5.5, foot prints (#2) full length of corridor column 3 to Academy Houses Concrete (School) Concrete surface out of tolerance. Floor drain concrete placed too high, column line L.5 to Academy Houses Concrete (School) Concrete surface out of tolerance. Uneven finish on floors at doors and Academy Houses Concrete (School) Concrete surface out of tolerance at two locations 1) Col. 7.8 to 7 and R.7 to S about 8 by 30' 2) Col.2.7 to 3.2 and R.7 to S about 8 by 20 feet. AB AB AB AB AB P jpg P jpg P jpg P jpg P jpg Print Date: 7/3/01 Page 5 of 154

6 DISCLAIMER: THE DISTRICT PROVIDES INFORMATION ABOUT THE DOCUMENTS AVAILABLE FOR REVIEW. THIS INFORMATION IS INFORMATIONAL ONLY AND THE DISTRICT DOES NOT WARRANT THAT THE INF COMPLETE OR CURRENT. ALTHOUGH EVERY REASONABLE EFFORT HAS BEEN MADE TO MAKE THE INFORMATION AS COMPLETE AS POSSIBLE, ANYONE OR ANY ENTITY UTILIZING OR ACCESSING THIS INFORMAT PERFORM ITS OWN DUE DILIGENCE AND MAY NOT RELY ON THE SUPPLIED INFORMATION ALONE. Los Angeles Unified School District Belmont Learning Complex Request for Proposal IOR Deficiency Report by Specification Number ID Spec. Section <1> Location Trade Description Drawing # Image # <2> Academy Houses Concrete (School) East-West joint in concrete floor slab at column line P, surface uneven and contains AB P jpg voids Academy Houses Concrete (School) Foot prints in concrete, column line M.2 and 3, about 4 by 8 foot area. AB P jpg Academy Houses Concrete (School) Floor slab placed too high and floor drain will not receive water at column line R.7 and 3- AB P jpg Academy Houses Concrete (School) Cold joint and voids at column line S near doors Total of about 20' lineal. AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance at deck drains, 5 total. Column line 3, 3.5, 4.5, 5.8 and AB P jpg 6.8 at line R Academy Houses Concrete (School) Concrete surface out of tolerance in triangle shaped area, outside rooms 214 & 216. AB P jpg Academy Houses Concrete (School) Concrete slab outside of doors , triangle shaped area, two total, concrete uneven. AB P jpg About 24 square feet total Academy Houses Concrete (School) East-West joint in concrete floor at column line P, surface uneven and contains voids. AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance imperresions in concrete slab, column line 3 to 2.7 and AB P jpg N to N.5 about 10 by 12 foot area Academy Houses Concrete (School) Concrete surface out of tolerance, 2 locations, column line P.3 and Q.3 at 3. AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance, near column line 4.2 and N.3, about 20 square feet. AB P jpg Academy Houses Concrete (School) Foot prints in concrete near column line N, from 6 to 6.6. About 2 by 8 feet. AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance. AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance at floor drains, 5 total. Column line 3, 3.5, 4.5, 5.8 and AB P jpg 6.8 at line R Academy Houses Concrete (School) Concrete surface out of tolerance near stairs, N to N.3 from 6 to 6.8 also uneven (1 1/2") AB P jpg area expected about 120 square feet Academy Houses Concrete (School) Concrete joint irregular and voids column line N near doors AB P jpg Academy Houses Concrete (School) Joint in floor slab with voids, column line S near door AB P jpg Academy Houses Concrete (School) Concrete surface out of tolerance two locations; 1) Column 7.8 to 7 and R.7 to S, about 8 AB P jpg by 30', 2) Column 2.7 to 3.2 and R.7 to S Academy Houses Concrete (School) Concrete surface out of tolerance. Steep sloped elevation change in concrete column line AB P jpg S at doors about 1 1/2" high Academy Houses Electrical (School) 2 Floor penetrations for temporary power require repair of holes and temporary fire AB P jpg stopping at L Academy Houses General Contracting Temporary steel safety rail posts project 1/2" +/- above finish floor, total of 42 locations. AB P jpg Academy Houses General Contracting Hole thru floor slab to floor below, one 2", 2' North of door 218 at corridor to room 218. AB Academy Houses General Contracting Steel safety rail post locations, holes and irregular surfaces at concrete floor slabs. Total AB P jpg of 27 locations Academy Houses General Contracting Steel safety rail posts are not cut off at finish floor. Up about 1/2" at shafts and exterior AB P jpg walls. Total of 27 locations with one post not cut at room Academy Houses General Contracting Hole in slab used for safety rail post to be filled (10) and 6 angles not burnt flush to slab AB P jpg to be ground flush with slab Academy Houses General Contracting Concrete finish irregular room 210, chips in concrete floor 20 locations, holes in slab AB P jpg where safety rail posts removed 23 locations, safety rail posts project above finish floor 9 locations Academy Houses General Contracting Holes in elevated slab need patching. AB P jpg Print Date: 7/3/01 Page 6 of 154

7 DISCLAIMER: THE DISTRICT PROVIDES INFORMATION ABOUT THE DOCUMENTS AVAILABLE FOR REVIEW. THIS INFORMATION IS INFORMATIONAL ONLY AND THE DISTRICT DOES NOT WARRANT THAT THE INF COMPLETE OR CURRENT. ALTHOUGH EVERY REASONABLE EFFORT HAS BEEN MADE TO MAKE THE INFORMATION AS COMPLETE AS POSSIBLE, ANYONE OR ANY ENTITY UTILIZING OR ACCESSING THIS INFORMAT PERFORM ITS OWN DUE DILIGENCE AND MAY NOT RELY ON THE SUPPLIED INFORMATION ALONE. Los Angeles Unified School District Belmont Learning Complex Request for Proposal IOR Deficiency Report by Specification Number ID Spec. Section <1> Location Trade Description Drawing # Image # <2> Academy Houses General Contracting Steel safety posts 1/2"+1- above concrete floor slab with open holes at square tubes, total AB P jpg of 30 locations Academy Houses Roofing and Waterproofing Floor flashing at wall at deck drain too high, not sealed, one location. Column 5.8 and AB P jpg R Administration Concrete (School) Slab on grade concrete has not been placed. AE-1.01 P jpg Administration Concrete (School) Reinforcing steel that is bent or broken to be replaced. All rusty bar to be cleaned. All AE-1.01 P jpg reinforcing bars that are bent, broken and rusty shall be corrected before concrete placement Administration Concrete (School) Concrete surface out of tolerance. Rough floor finish, 2 locations about 20' square each. AE-1.02 P jpg Administration Concrete (School) Concrete surface out of tolerance. Floor out of level up to 3/4" from column line B.5 to D AE-1.02 and 2 to Administration Concrete (School) No floor concrete placed at top of stair, about 6 by 3 feet. AE-1.02 P jpg Administration Concrete (School) Foundation and footing for masonry walls and columns have not been placed. SE-1.1 P jpg Parking Garage Cast-in-Place Concrete (Parking) Finish floor ramp from Parking Level 2 to Parking Level 1. Interior finish slab out of tolerance 1/2". P jpg Parking Garage Cast-in-Place Concrete (Parking) Concrete stair trend do not have warning spripes. AA 1.03 P jpg Parking Garage Cast-in-Place Concrete (Parking) Two block outs at floor slab elev. For door frame remove wood - patch Concrete slab as AA 1.04 P jpg required Parking Garage Cast-in-Place Concrete (Parking) Correction of cold joint where concrete column angle butts with concrete beam North AA 1.05 P jpg wall side at N-2 horizontal joint Parking Garage Cast-in-Place Concrete (Parking) Finish floor to be level 1/8 inch to 10 feet section not acceptable to specification for interior finish slabs (out of tolerance by 1/2") AA 1.07 P jpg Parking Garage Cast-in-Place Concrete (Parking) Finish floor ramp from PL-3 to PL-2. Interior finish slab out of tolerance by 1/2". AA 1.08 P jpg Parking Garage Cast-in-Place Concrete (Parking) Holes in slab on grade concrete. AA-1.01 P jpg Parking Garage Cast-in-Place Concrete (Parking) Concrete stairs to lower Parking Level. Do not have stair tread warning strips per ADA AA-1.02 P jpg requirements Parking Garage Cast-in-Place Concrete (Parking) Concrete stairs to lower Parking Level. Do not have stair tread warning strips per ADA AA-1.02 P jpg requirements Parking Garage Cast-in-Place Concrete (Parking) At concrete column on north-west corner and south-east corner repair damage at 24" max AA-1.07 P jpg from deck Parking Garage Cast-in-Place Concrete (Parking) Snap ties and are exposed in ceiling of stair shaft. P 306 P jpg Parking Garage Electrical (School) Concrete wall on 7.5 line and level # 2 wall and over head in corridor have not been AA P jpg finished. Example: Snap tie holes, form edges uneven and concrete drips Parking Garage Electrical (School) Correction of hole on slab on grade for mislocated conduit into gypsum wall. AA 1.03 P jpg Site-Wide Concrete/Masonry/Reinforcing Steel (Site Retaining Walls) From 2+40 to end of wall 1+00 footing not placed. C-1.12 P jpg Print Date: 7/3/01 Page 7 of 154

8 DISCLAIMER: THE DISTRICT PROVIDES INFORMATION ABOUT THE DOCUMENTS AVAILABLE FOR REVIEW. THIS INFORMATION IS INFORMATIONAL ONLY AND THE DISTRICT DOES NOT WARRANT THAT THE INF COMPLETE OR CURRENT. ALTHOUGH EVERY REASONABLE EFFORT HAS BEEN MADE TO MAKE THE INFORMATION AS COMPLETE AS POSSIBLE, ANYONE OR ANY ENTITY UTILIZING OR ACCESSING THIS INFORMAT PERFORM ITS OWN DUE DILIGENCE AND MAY NOT RELY ON THE SUPPLIED INFORMATION ALONE. Los Angeles Unified School District Belmont Learning Complex Request for Proposal IOR Deficiency Report by Specification Number ID Spec. Section <1> Location Trade Description Drawing # Image # <2> Site-Wide Concrete/Masonry/Reinforcing Steel (Site From station to end of wall at station foundation is not placed. C-1.12 P jpg Retaining Walls) Site-Wide Concrete/Masonry/Reinforcing Steel (Site From 2+40 to end of wall 1+00 footing not placed. C-1.12 P jpg Retaining Walls) Site-Wide Concrete/Masonry/Reinforcing Steel (Site From station 5+72 to station 4+96 footing for masonry wall not placed. C-1.13 P jpg Retaining Walls) Triple Gym Metal Deck and Insulating Concrete Cement stains on block from concrete placed at roof deck typical 3 rooms. Total 5 rooms. P jpg Triple Gym Metal Deck and Insulating Concrete Concrete stains on block walls, typical, from concrete placed at roof deck. Typical this AC1.01 P jpg room Academy Houses Reinforced Masonry and Veneer Systems CMU walls are not complete at stair tower walls. P jpg Academy Houses Reinforced Masonry and Veneer Systems Sprinkler branch lines is embodied in CMU wall 1" clearance is not provided over access AB P jpg door at N and N Academy Houses Reinforced Masonry and Veneer Systems Top of parapet CMU wall not complete. AB P jpg Academy Houses Reinforced Masonry and Veneer Systems Top of spandrel rail at CMU wall not complete. AB P jpg Academy Houses Reinforced Masonry and Veneer Systems CMU veneer at elevator and door 102 is not installed. AB P jpg Academy Houses Reinforced Masonry and Veneer Systems CMU at top of wall has not been installed. AB P jpg Administration Reinforced Masonry and Veneer Systems Masonry wall not built to correct height about 2' short of bottom of roof deck, about 45' AE-1.03 P jpg long. Column line 2.7 to 3 and D to D Parking Garage Drywall/EIFS/SOFP CMU wall not caulked at end and top as required. S-0.4 P jpg Parking Garage Drywall/EIFS/SOFP Compressable material and caulk missing at top and sides of walls. SA-1.3 P jpg Parking Garage Reinforced Masonry and Veneer Systems CMU walls in area exhibit efforcesence required to be corrected. AA 1.09 P jpg Parking Garage Reinforced Masonry and Veneer Systems CMU wall at louver opening top course not complete. AA-1.07 P jpg Academy Houses Reinforced Masonry and Veneer Systems At elevation masonry wall has not been built, rebar bent and rusted. AA-2.05 P jpg Academy Houses Reinforced Masonry and Veneer Systems Concrete floor: Motar droppings (#3) full width of corridor and full length. AB P jpg Academy Houses Reinforced Masonry and Veneer Systems Concrete floors: Motar dropings (#3) full width of corridor, column 4 to 5. AB P jpg Academy Houses Reinforced Masonry and Veneer Systems Concrete floor: Motar droppings (#3) full width of corridor, column 3 to 5.5. AB P jpg Academy Houses Reinforced Masonry and Veneer Systems Mitered corners have poor tooling and mortar missing in corridors S, 3 and N. AB P jpg Academy Houses Reinforced Masonry and Veneer Systems Mitered corners are poorly tooled and missing mortar in corridors S, 3 and N. AB P jpg Academy Houses Reinforced Masonry and Veneer Systems Mitered corners are poorly tooled and missing mortar in corridors S, 3 and N. AB P jpg Administration Drywall/EIFS/SOFP No caulked joints at masonry expansion joints, 7 locations. AE-1.03 P jpg Administration Reinforced Masonry and Veneer Systems Void between thru steel beams and masonry at beam pocket. Typical 12 locations. AE-1.02 P jpg Administration Reinforced Masonry and Veneer Systems Cold joint cracking at corner where two different walls meet. AE-1.02 P jpg Administration Reinforced Masonry and Veneer Systems Beams thru masonry walls have not been grouted in place. AE-1.1 P jpg Parking Garage Drywall/EIFS/SOFP Masonry wall not fire safed at top of wall. AA 1.07 P jpg Parking Garage Drywall/EIFS/SOFP Wood shims left in top of wall and penetrating fire safeing AA-1.06 P jpg Parking Garage Drywall/EIFS/SOFP Masonry walls at top and sides not fire safed. AA-1.07 P jpg Parking Garage Drywall/EIFS/SOFP Compressable material and caulk not done at top and sides of wall. AA-1.07 P jpg Parking Garage Drywall/EIFS/SOFP Edge of deck at masonry not fire safed. AA-1.07 P jpg Parking Garage Drywall/EIFS/SOFP Top of masonry wall has not been fire safed. AA-1.07 P jpg Parking Garage Miscellaneous Iron and Steel Stairs Vehicle corner guards not installed. AA 1.07 P jpg Print Date: 7/3/01 Page 8 of 154

9 DISCLAIMER: THE DISTRICT PROVIDES INFORMATION ABOUT THE DOCUMENTS AVAILABLE FOR REVIEW. THIS INFORMATION IS INFORMATIONAL ONLY AND THE DISTRICT DOES NOT WARRANT THAT THE INF COMPLETE OR CURRENT. ALTHOUGH EVERY REASONABLE EFFORT HAS BEEN MADE TO MAKE THE INFORMATION AS COMPLETE AS POSSIBLE, ANYONE OR ANY ENTITY UTILIZING OR ACCESSING THIS INFORMAT PERFORM ITS OWN DUE DILIGENCE AND MAY NOT RELY ON THE SUPPLIED INFORMATION ALONE. Los Angeles Unified School District Belmont Learning Complex Request for Proposal IOR Deficiency Report by Specification Number ID Spec. Section <1> Location Trade Description Drawing # Image # <2> Parking Garage Reinforced Masonry and Veneer Systems Door sill not complete, missing grout. P jpg Parking Garage Reinforced Masonry and Veneer Systems Top of wall not properly fire caulked at CMU wall. AA 109 P jpg Parking Garage Reinforced Masonry and Veneer Systems Masonry sill solider course not done. AA-1.01 P jpg Parking Garage Reinforced Masonry and Veneer Systems Cap block missing at top of 4' wall. AA-1.01 P jpg Parking Garage Reinforced Masonry and Veneer Systems Dowels and block at store front window sill not done to above print detail. AA Parking Garage Reinforced Masonry and Veneer Systems At entrance to elevator CMU toothed - not per spec. AA-1.03 P jpg Parking Garage Reinforced Masonry and Veneer Systems Veneer work from 6' 6" to 10' above footing chipped off and not replaced. AA-1.03 P jpg Parking Garage Reinforced Masonry and Veneer Systems Block missing under duct work. AA-1.06 P jpg Parking Garage Reinforced Masonry and Veneer Systems Masonry wall I course below window not layed. AA-1.07 P jpg Parking Garage Reinforced Masonry and Veneer Systems Wall over door at generator room incomplete. AA-1.07 P jpg Parking Garage Reinforced Masonry and Veneer Systems Block missing at top of wall where conduit penetrates wall. AA-1.07 P jpg Parking Garage Reinforced Masonry and Veneer Systems CMU top row last course at openings along wall not complete at louvers 14 total. AA P jpg Parking Garage Reinforced Masonry and Veneer Systems Large opening in CMU South and North elevator shaft walls not complete. Note: AB P jpg Structure steel beam penetrates thru both walls of elevator shaft Parking Garage Reinforced Masonry and Veneer Systems Masonry work incomplete. Not to detail above. SA- P jpg Parking Garage Reinforced Masonry and Veneer Systems Masonry work incomplete. Dowles for horizontal bars missing. Work not to detail. SA-1.01 P jpg Bars bent Site-Wide Concrete/Masonry/Reinforcing Steel (Site From elevation to station masonry wall incomplete, not grouted an rebar C-1.12 P jpg Retaining Walls) rusted Site-Wide Concrete/Masonry/Reinforcing Steel (Site From station to station rebar have been cut flush with concrete starter C-1.12 P jpg Retaining Walls) wall Site-Wide Concrete/Masonry/Reinforcing Steel (Site From station to station st course of masonry laid. Vertical reinforcing C-1.12 P jpg Retaining Walls) badly rusted and needs to be cleaned Site-Wide Concrete/Masonry/Reinforcing Steel (Site From station 5+72 to station 4+96 masonry wall not erected. C-1.13 P jpg Retaining Walls) Triple Gym Drywall/EIFS/SOFP Control joint at CMU to CMU North-South walls caulking not completed location at W- AC-1.02 P jpg 3.5 and V Triple Gym Reinforced Masonry and Veneer Systems Beam not grouted at CMU wall 4 locations. P jpg Triple Gym Reinforced Masonry and Veneer Systems Cement stains on block. Typical these rooms. P jpg Triple Gym Reinforced Masonry and Veneer Systems Grout around beam penetration at CMU wall above entrance door and West wall. P jpg Triple Gym Reinforced Masonry and Veneer Systems Beam penetration thru CMU wall has not been grouted. AC 1.00 P jpg Triple Gym Reinforced Masonry and Veneer Systems Wood embedded in CMU wall for openning at North wall. AC Triple Gym Reinforced Masonry and Veneer Systems Grouting and/or dry packing of area under structural steel member where penetration of AC-1.02 P jpg CMU walls occurred has not been completed at East-West-South walls Triple Gym Reinforced Masonry and Veneer Systems Grouting or dry pack of beam past thru CMU wall is not completed at East-South. AC-1.02 P jpg Triple Gym Reinforced Masonry and Veneer Systems Grouting and/or dry packing of area under structural steel beam where penetration of AC-1.02 P jpg CMU wall occures have not been completed total of 4 areas effected in Team room and entrance area Triple Gym Reinforced Masonry and Veneer Systems Block out at CMU wall at line 3.8 correction required. Left space void. AC-1.02 P jpg Triple Gym Reinforced Masonry and Veneer Systems Grouting and/or dry packing of area under structure steel members where penetration of AC-1.02 P jpg CMU wall occures have not been completed. 5 Different areas effected in room Triple Gym Reinforced Masonry and Veneer Systems Grout stain from top of elec. box down typical condition on wall. AC-1.02 P jpg Triple Gym Reinforced Masonry and Veneer Systems CMU block cut out. Penetration at 3.8 line correction required (Left space void). AC-1.02 P jpg Triple Gym Reinforced Masonry and Veneer Systems Wood forms in block wall for 12 by 12 openings, 3 total. AC1.01 P jpg Print Date: 7/3/01 Page 9 of 154

10 DISCLAIMER: THE DISTRICT PROVIDES INFORMATION ABOUT THE DOCUMENTS AVAILABLE FOR REVIEW. THIS INFORMATION IS INFORMATIONAL ONLY AND THE DISTRICT DOES NOT WARRANT THAT THE INF COMPLETE OR CURRENT. ALTHOUGH EVERY REASONABLE EFFORT HAS BEEN MADE TO MAKE THE INFORMATION AS COMPLETE AS POSSIBLE, ANYONE OR ANY ENTITY UTILIZING OR ACCESSING THIS INFORMAT PERFORM ITS OWN DUE DILIGENCE AND MAY NOT RELY ON THE SUPPLIED INFORMATION ALONE. Los Angeles Unified School District Belmont Learning Complex Request for Proposal IOR Deficiency Report by Specification Number ID Spec. Section <1> Location Trade Description Drawing # Image # <2> Triple Gym Reinforced Masonry and Veneer Systems Hair line cracking of CMU parapet wall and CMU wall on at line DD at five different AC1.01 P jpg spots, on line CC at three different spots Triple Gym Reinforced Masonry and Veneer Systems Masonry beam between lines 4.2 to 5.5 at DD line is sagging about 3/4" at roof parapet AC1.01 P jpg elevation Triple Gym Reinforced Masonry and Veneer Systems Hair line cracking at CMU joints and bottom side of CMU joints have not been grouted AC1.01 P jpg or tooled in area noted Triple Gym Reinforced Masonry and Veneer Systems Open beam pocket no masonry or concrete for roof beam, one location East wall. AC1.01 P jpg Triple Gym Reinforced Masonry and Veneer Systems Beam pocket for thru steel roof beam not filled in with masonry/concrete. Typical 2 AC1.01 P jpg locations Triple Gym Reinforced Masonry and Veneer Systems Rebar floor dowels also horizontal bars at door openings coated with cement, typical. AC1.01 P jpg Triple Gym Reinforced Masonry and Veneer Systems Concrete trash not removed. One location, about 3" by 3". AC1.01 P jpg Triple Gym Reinforced Masonry and Veneer Systems Cement stains on concrete block. Typical all walls. AC1.01 P jpg Triple Gym Reinforced Masonry and Veneer Systems Typical condition: Efflorescent on CMU walls North, South, West sides of exterior walls. AC1.01 P jpg Triple Gym Reinforced Masonry and Veneer Systems Concrete stains on block walls, typical this room. AC1.01 P jpg Triple Gym Reinforced Masonry and Veneer Systems Open beam pockets for through the wall steel roof beams. No masonry two openings AC1.01 P jpg (One each East and West walls) Triple Gym Reinforced Masonry and Veneer Systems Cement on block walls, typical. AC1.01 P jpg Triple Gym Reinforced Masonry and Veneer Systems Temp. wood frames not removed from masonry openings, 2 total 8 1/2" by 8 1/2". AC1.01 P jpg Triple Gym Reinforced Masonry and Veneer Systems Concrete stains on block, typical. AC1.01 P jpg Triple Gym Reinforced Masonry and Veneer Systems Cement stains on block, typical. AC1.01 P jpg Triple Gym Reinforced Masonry and Veneer Systems Temp. wood forms not removed from two, 12" by 12" openings in attic. AC1.01 P jpg Triple Gym Reinforced Masonry and Veneer Systems 3/16 Gap-crack found on CMU parapet wall-crack stair steps down from top of parapet SC1.03 P jpg wall landing down under beam ledger angle located at North wall, approx. 1' from West side Triple Gym Reinforced Masonry and Veneer Systems 1/16 Gap crack found on CMU parapet wall. Crack steps down from top of parapet wall, SC1.03 P jpg leading down under beam ledger angle. Located at West wall approx. 1' to 2' from North side Academy Houses Drywall/EIFS/SOFP Door frames not caulked where block veneer abutts, door jambs and door head, typical. AB P jpg Level 1 at 16 doors total Academy Houses Drywall/EIFS/SOFP Backer rod and caulking at top of masonry veneer and EIFS ceiling not started at level 1 AB P jpg and 2. Note: Level 3 veneer not installed. This is a typical condition Academy Houses Reinforced Masonry and Veneer Systems From elevation to top of roof parapet masonry veneer has not been installed. P jpg Academy Houses Reinforced Masonry and Veneer Systems From to masonry veneer is showing efflorescence. P jpg Academy Houses Reinforced Masonry and Veneer Systems From elevation to top of parapet, craft paper and veneer track has not been AA-2.01 P jpg installed Academy Houses Reinforced Masonry and Veneer Systems From elevation to top of parapet no craft or veneer track has been installed. AA-2.02 P jpg Academy Houses Reinforced Masonry and Veneer Systems From elevation to top of parapet craft paper and veneer track has not been AA-2.02 P jpg installed Academy Houses Reinforced Masonry and Veneer Systems Masonry veneer is incomplete. AA P jpg Academy Houses Reinforced Masonry and Veneer Systems From elevation to masonry veneer incomplete from to top of parapet craft paper and veneer track not installed. AA-2.06 P jpg Print Date: 7/3/01 Page 10 of 154

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1 16 May 2014 Page 1 PART 1 GENERAL 1.1 DESCRIPTION This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories

More information

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings Building Safety Department 400-2 nd Street South St. Cloud, MN 56301 (320) 255-7239 A building permit is required for any accessory

More information

SECTION NON-STRUCTURAL METAL FRAMING

SECTION NON-STRUCTURAL METAL FRAMING SECTION 09 22 16 PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories

More information

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. SECTION 06110 WOOD FRAMING PART 1 GENERAL 1.1 SUMMARY A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But Not Supplied

More information

WCU ALUMNI TOWER MASONRY & ENVELOPE REPAIRS

WCU ALUMNI TOWER MASONRY & ENVELOPE REPAIRS SCO #: 8-8-0 TABLE OF CONTE COV DESCRIPTION COVER SHEET ALUMNI TOWER ELEVATIONS & PLAN VIEWS REPAIR DETAILS - M TO REPAIR DETAILS - TO M0 & C TO REPAIR DETAILS - A & F TO F VICINITY MAP ALUMNI TOWER ALUMNI

More information

Residential Building Inspections

Residential Building Inspections Residential Building Inspections Foundations, Grade Beams, Pile Caps, Foundation Pads 1. All trenches or excavations and formwork shall be in accordance with the size(s) and configuration(s) as per approved

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Building Excellence IV Capital Levy Projects Under Construction

Building Excellence IV Capital Levy Projects Under Construction Building Excellence IV Capital Levy Projects Under Construction Project Slide Number Arbor Heights Elementary School 2 Cascadia Elementary School & Robert Eagle Staff Middle School 13 Genesee Hill Elementary

More information

2003 International Residential Building Code

2003 International Residential Building Code 2003 International Residential Building Code Section R305 Ceiling Height Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less

More information

Contractor/Owner initials are verification that items #1 and #2 and items (a) thru (g) above are included in the submitted plan/drawing.

Contractor/Owner initials are verification that items #1 and #2 and items (a) thru (g) above are included in the submitted plan/drawing. FINISH BASEMENT/ADDITION/REMODEL PLAN CORRECTIONS LIST (Based on the current Editions of the International Codes and National Electrical Code) PLAN CHECKED BY: LOT/SUBDIVISION/ADDRESS: CONTRACTOR OR OWNER/BUILDER:

More information

Table of Contents. Page Title

Table of Contents. Page Title Page Title Table of Contents 1 Floor plan/ Room utilization 2 Elevation (EAST) 3 Elevation (SOUTH) 4 Elevation (WEST) 5 Elevation (NORTH) 6 Foundation plan details 7 Foundation cross sections A Main grade

More information

Administrative Changes

Administrative Changes Revised 11/29/06 Knox County Residential Building Codes Significant Changes From The 1995 CABO One And Two Family Dwelling Code To The 2006 International Residential Code All one and two family dwellings

More information

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING

SECTION HANGERS AND SUPPORTS FOR PLUMBING SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage The following list of code requirements is intended to assist you in complying with the Code of Public

More information

NSC North Star Contracting, l.l.c

NSC North Star Contracting, l.l.c NSC North Star Contracting, l.l.c PROCEDURES MANUAL PRELIMINARY DATA REQUEST STRUCTURAL 1. Engineer s Frame, Specs & Schedule 2. Roof and Floor Truss Layout, Bearing Point loads for Beams & Girder Locations

More information

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents. SECTION 06 1100 WOOD FRAMING PART 1 - GENERAL 1.1 SUMMARY A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But

More information

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits. SECTION 09 2216 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and

More information

Building Division Informational Handout

Building Division Informational Handout CITY OF SAN JOSÉ, CALIFORNIA Building Division Informational Handout Conventional Light Frame Construction Design Provisions 2007 CBC Handout No. 2-21 Published: 1/1/08 Page 1 of 3 This document summarizes

More information

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 29 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of work

More information

6'-0" G-4 ADJUSTABLE SHELVING 2'-0" 4'-5" MOP SINK STORAGE '-0" 2'-0" 26'-6" G-4 6' X 4' OPENING WITH SHUTTER BASE CABINETS 34" FOR ADA 20'-0"

6'-0 G-4 ADJUSTABLE SHELVING 2'-0 4'-5 MOP SINK STORAGE '-0 2'-0 26'-6 G-4 6' X 4' OPENING WITH SHUTTER BASE CABINETS 34 FOR ADA 20'-0 2 G1 3'4" 4'0" ROOM FINISH SCHEDULE 4'0" F.F. WINDOW DETAILS GROUT CORES SOLID GROUT CORES SOLID 3 G1 #5 BARS HOLLOW METAL FRAME INSULATED GLASS 1" CLEAR INSULATED (U=0.45) CAULKING & BACKER ROD PREFORMED

More information

TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ S201 TW: 89'-0" TF: 86'-0" S201 TW: 87'-11 1/4" S201 TF: 86'-10 1/4" S201

TP: 89'-0 BP: 86'-6 1/4 2'-0 Typ TP: 89'-0 BP: 86'-6 1/4 2'-0 Typ S201 TW: 89'-0 TF: 86'-0 S201 TW: 87'-11 1/4 S201 TF: 86'-10 1/4 S201 Resource reginc.com 0.. '-" P: '-" 0'-0" " P: '- /" 0'-" '-" '-0" '-0" 0'-0" '-0" '-" '- /" TF: '-0" TW: '-0" TF: '-0" TW: '-0" TF: '-0" TW: '- /" TF: '-" " Typ Sim. P: '-" " TF: '-0" C '- /" '-" Varies

More information

INSTALLATION CHECKLIST 2 ND EDITION. Fox Blocks Abbott Drive Omaha, NE

INSTALLATION CHECKLIST 2 ND EDITION. Fox Blocks Abbott Drive Omaha, NE Fox Blocks INSTALLATION CHECKLIST ND EDITION Fox Blocks Installation Checklist: ND Edition 6110 Abbott Drive Omaha, NE 6110-69-6 WWW.FOXBLOCKS.COM INSTALLATION CHECKLISTS The Checklists on the following

More information

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE: SECTION 07651 FLEXIBLE COPPER SHEET FLASHINGS Advanced Building Products, Inc. manufacturer many types of flexible copper sheet flashings. Due to their ductility, high tensile strength, and resistance

More information

HILLVIEW ELEMENTARY ADDITIONS AND ALTERATIONS Grove City Area School District

HILLVIEW ELEMENTARY ADDITIONS AND ALTERATIONS Grove City Area School District HILLVIEW ELEMENTARY ADDITIONS AND ALTERATIONS Grove City Area School District Facilities and School Safety Committee Meeting October 25, 2018 Progress Update PROGRESS UPDATE Rien Construction (General

More information

ORDINANCE NO BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF BOULDER, COLORADO: CHAPTER 98 - Baled Straw Structures SECTION PURPOSE

ORDINANCE NO BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF BOULDER, COLORADO: CHAPTER 98 - Baled Straw Structures SECTION PURPOSE ORDINANCE NO. 5891 AN ORDINANCE AMENDING CHAPTER 10-5, B.R.C. 1981, CONCERNING ALTERNATIVE BUILDING MATERIALS, INCLUDING ADOBE AND STRAW BALE CONSTRUCTION AND RECYCLED LUMBER. BE IT ORDAINED BY THE CITY

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 260548 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel

More information

TABLE OF CONTENTS Public Safety Building

TABLE OF CONTENTS Public Safety Building DOCUMENT 00 01 10 - TABLE OF CONTENTS VOLUME I DIVISION 00 PROCUREMENT AND CONTRACTING REQUIREMENTS 00 01 10 Table of Contents 00 31 32 Geotechnical Data DIVISION 01 GENERAL REQUIREMENTS 01 10 00 Summary

More information

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING DIVISION 5 METALS SECTION 05 40 00 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Stone and Masonry Veneer

Stone and Masonry Veneer Stone and Masonry Veneer R703.7 Stone and masonry veneer, general. Stone and masonry veneer shall be installed in accordance with this chapter, Table R703.4 and Figure R703.7. These veneers installed over

More information

SITE AND BUILDING INSPECTION CHECKLIST

SITE AND BUILDING INSPECTION CHECKLIST PARISH BUILDING Page 1 of 6 SITE AND GROUNDS DATE INIT COMMENTS DATE INIT COMMENTS Ramps & Provisions for Handicap Designated parking spaces for Handicap Has soil dropped or heaved Is there standing water

More information

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology FLASHING DETAILS FOR CONCRETE MASONRY WALLS TEK 19-5A Water Penetration Resistance

More information

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC) Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC) Plan Check Submittal Date: Plan Check #: Permit App.# Job Address: Applicant: Phone: ( ) Plan Check Engineer:

More information

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016 February 2016 Residential Deck Safety, Construction and Repair Juneau Permit Center, 4 th Floor Marine View Center,(907)586-0770 This handout is designed to help you build your deck to comply with the

More information

SECTION NON-STRUCTURAL METAL FRAMING

SECTION NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 22 16 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE: IRC CODE UPDATES TO: RESIDENTIAL BUILDING CONTRACTORS FROM: GARY STABER, BUILDING OFFICIAL SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE: 6/1/2003 INTERNATIONAL RESIDENTIAL CODE (IRC) APPLICABILITY:

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION ITEM 03100 CONCRETE FORMWORK 1.0 GENERAL 1.1 DESCRIPTION This section defines requirements and limitations for design, construction, erection, and removal of concrete formwork for

More information

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3% CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE EXAM ID: I6 80 multiple-choice questions 3-1/2-hour time limit Open book 01. GENERAL ADMINISTRATION 3 % 0101. Project Administration 3% Verify that plans,

More information

Concrete Framing Systems - Walls and Columns

Concrete Framing Systems - Walls and Columns Concrete Framing Systems - Walls and Columns Casting a Concrete Wall Wall Footing Reinforcing Wall Forms Pouring Concrete Finishing the Concrete Controlling Cracking Insulating Concrete Forms (ICF) Tilt-Up

More information

SECTION UNIT MASONRY

SECTION UNIT MASONRY SECTION 04200 UNIT MASONRY PART 1 GENERAL 1.01 SUMMARY A. Furnish labor, materials, and equipment and perform functions required in the installation and maintenance of the work covered by this Section.

More information

ELECTRICAL SECTION 2

ELECTRICAL SECTION 2 ELECTRICAL SECTION 2 COMMON WORK RESULTS FOR ELECTRICAL PART 1 - GENERAL 1.1 GENERAL REQUIREMENTS A. This Section includes raceways, conductors and cables, grounding materials, boxes, electrical identification

More information

SEISMIC RESTRAINT SYSTEM

SEISMIC RESTRAINT SYSTEM 1. GENERAL 1.1. Description: SECTION 16012 SEISMIC RESTRAINT SYSTEM 1.1.1. This specification covers design and installation of seismic bracing and anchorage required for conduit, cable tray, bus duct,

More information

A. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section

A. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section SECTION 15140 SUPPORTS, ANCHORS, AND SEALS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract including General and Supplementary Conditions, Division 1 Specification

More information

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC) Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC) Plan Check Submittal Date: Plan Check #: Permit App.# Job Address: Applicant: Phone: ( ) P.C. Engineer: Phone:

More information

East Lyme Middle School EAST LYME MIDDLE SCHOOL

East Lyme Middle School EAST LYME MIDDLE SCHOOL Description: N EAST LYME MIDDLE SCHOOL The school consists of a multi story building with lower, main and upper level floors. The typical floor framing for the main and upper levels is wide flange steel

More information

SPECIFICATION & DESIGN MANUAL " AISI 1060 to 1065 Rockwell Hardness 51 to 55 Perma-Seal coated Stick-E Pin 3/4" (Step Shank) 1"

SPECIFICATION & DESIGN MANUAL  AISI 1060 to 1065 Rockwell Hardness 51 to 55 Perma-Seal coated Stick-E Pin 3/4 (Step Shank) 1 Trak-It /Stick-E TM SPECIFICATION & DESIGN MANUAL TM Stick-E Electrical and Mechanical Fastening System PRODUCT DESCRIPTION The Stick-E fastening system uses Trak-It gas technology with specially designed

More information

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories 04 00 00 MASONRY 04 01 00 Maintenance of Masonry 04 01 20 Maintenance of Masonry 04 05 13 Masonry Mortaring 04 05 23 Masonry Accessories 04 20 00 UNIT MASONRY 04 21 00 Clay Unit and Brick Veneer 04 22

More information

Building Excellence IV Capital Levy Projects Under Construction

Building Excellence IV Capital Levy Projects Under Construction Building Excellence IV Capital Levy Projects Under Construction Project Slide Number Arbor Heights Elementary School 2 Cascadia Elementary School & Robert Eagle Staff Middle School 14 Genesee Hill Elementary

More information

Pulaski County, Virginia

Pulaski County, Virginia Pulaski County, Virginia Typical Carport Enclosure Details Based on the 2009 International Residential Code CONTENTS General Requirements... 2 Emergency Escape and Rescue... 2 Foundation and Floor... 3

More information

Plan Check No. Checked by: An Appointment Is Required for Verification

Plan Check No. Checked by: An Appointment Is Required for Verification SUPPLEMENTAL CORRECTION SHEET UNREINFORCED MASONRY (URM) RETROFIT ( 2002 LABC ) Plan Check No. Checked by: Permit Appl. # An Appointment Is Required for Verification Job Address: For appt. call: APPLICATION

More information

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers version 2.5 updated as of 08.04.2017 2 TABLE OF CONTENTS 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers 2.0 ASSEMBLY 2.1 Sequence of Assembly 2.2 Preparation

More information

Table of Contents. 1 Introduction. 2 Description. 3 Tools and materials. 4 Footings or slabs. 5 Coursing placement. 6 Reinforcing steel

Table of Contents. 1 Introduction. 2 Description. 3 Tools and materials. 4 Footings or slabs. 5 Coursing placement. 6 Reinforcing steel Table of Contents 1 Introduction 2 Description 3 Tools and materials 4 Footings or slabs 5 Coursing placement 6 Reinforcing steel 7 Alignment scaffold installation 8 Concrete placement 9 Exterior and interior

More information

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK DIVISION 5 - STRUCTURAL STEEL AND IRON WORK SECTION 05100 STRUCTURAL METAL FRAMING PART 1.00 GENERAL 1.01 SCOPE OF WORK A. Work Included: 1. 2. Structural steel complete in place. Steel joists complete

More information

METATEK POWER HOUSE CONSTRUCTION BUILDER S GUIDE CHECKLIST

METATEK POWER HOUSE CONSTRUCTION BUILDER S GUIDE CHECKLIST BUILDER S GUIDE & CHECKLIST 1 Table of Contents OVERVIEW... 2 CONSTRUCTION GUIDELINES... 2 DO NOT MODIFY LIST... 3 OPTIONAL LIST... 3 BUILDING DRAWINGS... 4 CHECKLIST... 4 MATERIALS LIST... 15 MATERIALS

More information

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC. 320-226.5189 www.101developmentresources.com While every attempt has been made to insure the correctness of this handout, no guarantees are made to its accuracy

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # SECTION 26 0529 - HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2) Inspection of Fabricators (1704.2) Furnish inspection reports (1704.2.1) - Fabricators that have not been approved Provide a Certificate of Compliance (1704.2.2) - Approved Fabricators Steel Construction

More information

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS SECTION 16711-27 05 28.33 PART 1 - GENERAL 1.01 SUMMARY A. This section includes Labor, materials and equipment necessary to complete the installation required for the items specified under this Section,

More information

SUPPORT AND ANCHORS SECTION 15090

SUPPORT AND ANCHORS SECTION 15090 SUPPORT AND ANCHORS SECTION 15090 PART 1 GENERAL 1.1 DESCRIPTION OF WORK A. Work included in this Section: Materials, equipment, fabrication, installation and tests in conformity with applicable codes

More information

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT Page 220548-1 SECTION 220548 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

1. Hangers and supports for electrical equipment and systems.

1. Hangers and supports for electrical equipment and systems. PART 1 - GENERAL... 1 1.1 RELATED DOCUMENTS... 1 1.2 SUMMARY... 1 1.3 DEFINITIONS... 1 1.4 PERFORMANCE REQUIREMENTS... 1 1.5 SUBMITTALS... 2 1.6 QUALITY ASSURANCE... 2 1.7 COORDINATION... 2 PART 2 - PRODUCTS...

More information

0103 Plan Reading 4% Read plans to verify the project conforms with the code, approved plans, and construction documents.

0103 Plan Reading 4% Read plans to verify the project conforms with the code, approved plans, and construction documents. Certification: Commercial Building Inspector Exam ID: B2 Scope: A Commercial Building Inspector will be responsible for performing inspections of structures to determine compliance with the various Building

More information

SECTION 11 Architectural and Nonstructural Elements Field Investigation

SECTION 11 Architectural and Nonstructural Elements Field Investigation SECTION 11 Architectural and Nonstructural Elements Field Investigation Types of Data to Be Collected and Recorded Research in these fields should be directed at determining the effect that architecture

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

30 X 40 POLE BARN 12 HIGH SIDE WALLS 2-12 WIDE X 10 HIGH SECTIONAL GARAGE DOORS OPTIONAL WINDOWS DETAILS INCLUDED

30 X 40 POLE BARN 12 HIGH SIDE WALLS 2-12 WIDE X 10 HIGH SECTIONAL GARAGE DOORS OPTIONAL WINDOWS DETAILS INCLUDED 30 X 40 POLE BARN 12 HIGH SIDE WALLS 2-12 WIDE X 10 HIGH SECTIONAL GARAGE DOORS OPTIONAL WINDOWS DETAILS INCLUDED 3 ENTRY DOOR METAL ROOF METAL SIDING GABLE ROOF, 4/12 PITCH INDEX PAGE DESCRIPTION 1 FRONT

More information

Smarter. Safer. Leaner.

Smarter. Safer. Leaner. Smarter. Safer. Leaner. Fast Installation and Removal Decrease Leading Edge Exposure by 87% OSHA Compliant Versatile and Reusable Use Perimeter Protection Posts During Construction: At Building Perimeter

More information

CITY OF SELMA, TEXAS Inspection Guidelines: Residential

CITY OF SELMA, TEXAS Inspection Guidelines: Residential Selma, Texas, located in Bexar, Comal, and Guadalupe Counties Responsible party: Larry Verner, P.E. City Engineer Ph. (210) 651-7828 lverner@ci.selma.tx.us The Permits and Inspections Department welcomes

More information

Light-Metal Roof Edge, Raised

Light-Metal Roof Edge, Raised NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 0548 - PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

CODE COMPLIANCE GUIDELINE GENERAL BUILDING CODE COMPLIANCE GUIDELINE This guideline has been prepared by The Calhoun County Building Department to assist Homebuilders, General Contractors, and Owner/Builders during the construction process. The

More information

Custom 22' x 40' - 16' Tall Garage Plan #g227 By SDS-CAD Specialized Design Systems

Custom 22' x 40' - 16' Tall Garage Plan #g227 By SDS-CAD Specialized Design Systems P O Box 34 Mendon, Utah Custom 22' x 40' - 16' Tall Garage Plan #g22 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 055113 - METAL PAN STAIRS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS SECTION 270528 PATHWAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Communications equipment coordination and installation. 2. Sleeves for pathways and cables. 3. Raceway

More information

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) PERMIT SUBMITTAL CHECKLIST: Signed and completed Building Permit application form. A separate Electrical permit is required from

More information

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507) Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN 55046 (507) 744-2327 fax (507) 744-5554 2006 RESIDENTIAL CONSTRUCTION CHECKLIST The following checklist has been designed

More information

* RESIDENTIAL PLAN REVIEW *

* RESIDENTIAL PLAN REVIEW * CITY OF DES MOINES, IOWA COMMUNITY DEVELOPMENT DEPARTMENT PERMIT AND DEVELOPMENT CENTER 602 Robert D. Ray Drive DES MOINES, IOWA 50309 Phone: 515.283.4200 Facsimile: 515.283.4270 Based on the scope of

More information

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco

More information

INSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST

INSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST Village of Vernon Hills Community Development Department - Building Division 290 Evergreen Drive, Vernon Hills, IL 60061 Phone 847-367-3704 - Fax 847-367-2541 - http://www.vernonhills.org INSPECTION TIMING

More information

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1% CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE EXAM ID: I1 80 multiple-choice questions 3-1/2-hour time limit Open book 01. GENERAL ADMINISTRATION 6% 0101. Project Administration 1% Verify that

More information

Custom 30 x 48-14' Tall Garage Plan #g226 By SDS-CAD Specialized Design Systems

Custom 30 x 48-14' Tall Garage Plan #g226 By SDS-CAD Specialized Design Systems P O Box 34 Mendon, Utah Custom 30 x 48-14' Tall Garage Plan #g226 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section

More information

1 AND 2 FAMILY DWELLING REQUIREMENTS

1 AND 2 FAMILY DWELLING REQUIREMENTS PLAN REQUIREMENTS: 1 AND 2 FAMILY DWELLING REQUIREMENTS All residential plans including additions and attached garages shall be designed to the current edition of the International Residential Code. Plans

More information

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1 SECTION SUPPORTING DEVICES

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1 SECTION SUPPORTING DEVICES KNOXVILLE, TENNESSEE SECTION 26 05 29 PAGE 1 PART 1 - GENERAL: 1.01 DESCRIPTION OF WORK: SECTION 26 05 29 A. Extent of supports, anchors, sleeves and seals is indicated by drawings and schedules and/or

More information

ThermaSteel Corporation ASSEMBLY MANUAL

ThermaSteel Corporation ASSEMBLY MANUAL ThermaSteel Corporation ASSEMBLY MANUAL TABLE OF CONTENTS 1- INTRODUCTION 1.1 THERMASTEEL TM WALL PANELS 1.2 Drawing and Element Numbers 2- ASSEMBLY 2.1 Sequence of Assembly 2.2 Preparation of Foundation

More information

INSPECTION REQUIREMENTS: FOUNDATIONS

INSPECTION REQUIREMENTS: FOUNDATIONS Foundations Page 1 of 9 Revision Date: 1/2/2018 DEVELOPMENT SERVICES BUILDING INSPECTION INSPECTION REQUIREMENTS: FOUNDATIONS INSPECTION CODE: 204 SCOPE: RESIDENTIAL APPLICABLE CODES: 2016 CBC, CRC, CPC,

More information

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 26 05 48 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel

More information

GENERAL MECHANICAL SYSTEM REQUIREMENTS

GENERAL MECHANICAL SYSTEM REQUIREMENTS CHAPTER 13 GENERAL MECHANICAL SYSTEM REQUIREMENTS SECTION M1301 GENERAL M1301.1 Scope. The provisionsof thischapter shall governthe installation of mechanical systems not specifically covered in other

More information

Preassembled steel stairs with concrete-filled treads.

Preassembled steel stairs with concrete-filled treads. SECTION 055113 - PART 1 - GENERAL 1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this

More information

FIELD COPY ATTACHMENT

FIELD COPY ATTACHMENT FIELD COPY ATTACHMENT The released plans for the project must be on site and available to the inspectors at all times. No inspection will be done without the released field plans. If you have any questions,

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 092216 - COLD FORMED STEEL FRAMING - NON-STRUCTURAL (CFSF-NS) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 ACTION

More information

THE FLORIDA BUILDING CODE

THE FLORIDA BUILDING CODE THE FLORIDA BUILDING CODE 1. According to the Florida Building Code, spiral stairway treads must all be identical and rise must be sufficient enough to provide a headroom of minimum. A. 6'- 4" B. 6'- 6"

More information

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION Page 210500-1 SECTION 210500 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Property Inspection Checklist

Property Inspection Checklist Property Inspection Checklist Use a checklist like this to make sure that you are looking at all parts of the house. Check off those items that are in good condition and make notes about those that are

More information

The Inspection Process. Waxhaw N.C.

The Inspection Process. Waxhaw N.C. The Inspection Process In Waxhaw N.C. This information is provided by the Waxhaw Enforcement Division to assist you in the progression of your project. Nothing in this document should be considered "Code"

More information

RUNNERS (Required to convert to real property)

RUNNERS (Required to convert to real property) HUMBOLDT COUNTY BUILDING DEPARTMENT MANUFACTURED HOUSE/MOBILE HOME RUNNERS & PERIMETER FOUNDATION These requirements apply to the construction of permanent foundations necessary to convert to real property.

More information

SFR SUBMITTAL REQUIREMENTS

SFR SUBMITTAL REQUIREMENTS A. FEES DUE AT TIME OF PERMIT APPLICATION The following non-refundable fees will be collected at the time of application for all residential projects. 1. Building Plan Check Fee B. CODES The City of Oak

More information

UCC Permit Application Procedures

UCC Permit Application Procedures How do I apply for a permit? UCC Permit Application Procedures 1. Please complete the CodeMaster Pan Review Application 2. Please provide the scope of work description and/or construction documents/plans.

More information

Pulaski County, Virginia Typical Carport Enclosure Details Based on the 2012 International Residential Code

Pulaski County, Virginia Typical Carport Enclosure Details Based on the 2012 International Residential Code Pulaski County, Virginia Typical Carport Enclosure Details Based on the 2012 International Residential Code Carports enclosed into one-story garages or living spaces must be constructed in conformance

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued) 2000 IRC 1997 NEHRP Section Provision Section Provision Comments CHAPTER 3 BUILDING PLANNING R301 DESIGN CRITERIA R301.2.2 Seismic Provisions R301.2.2.1 Determination of Seismic Design Category R301.2.2.1.1

More information