Vent Termination Chart. horizontal Termination Kit A. horizontal Termination Kit C. Chimney Liner Termination Kit. DirectVent Pro Direct Vent

Size: px
Start display at page:

Download "Vent Termination Chart. horizontal Termination Kit A. horizontal Termination Kit C. Chimney Liner Termination Kit. DirectVent Pro Direct Vent"

Transcription

1 irectvent Pro irect Vent Vent Termination hart H X 12 Minimum height Roof Pitch Feet Meters Flat to 7/ Over 7/12 to 8/ Over 8/12 to 9/ Over 9/12 to 10/ Over 10/12 to 11/ Over 11/12 to 12/ Over 12/12 to 14/ horizontal Termination Kit Kit includes: 90 black Elbow, eiling Support/Wall Thimble over, 2 black Pipe, black Pipe Extension. Termination cap not included. For x direct vent. hoose termination cap to complete installation. STOK # 46V-KH horizontal Termination Kit Kit includes: 90 black Elbow, Wall Thimble, eiling Support/ Wall Thimble over, 2 black Pipe, black Pipe Extension. Termination cap not included. For x direct vent. hoose termination cap to complete installation. STOK # 46V-KH himney Liner Termination Kit Kit includes: Termination onnector and Flashing. irectvent Pro x Termination aps, 3 Flex, and o-linear Flex onnectors are sold separately. irectvent Pro chimney liner termination kit must be tested and listed for each appliance. Refer to stove manufacturer s installation instructions. STOK # V-GK V-T Simpson ura-vent

2 irect Vent irectvent Pro Masonry himney onversion Kit 8¼ ⅝ Kit 46V-KM includes: ap dapter, 18 x 18 Flashing, Round eiling Support/Wall Thimble over, Retro onnector. For x direct vent. Termination ap and flex are sold separately. Kit 46V-KT includes: ap dapter and a 18 x 18 Flashing. Use with x direct vent gas stoves. Use existing masonry chimney. Route the exhaust gases and intake air through the side of the masonry chimney. 6⅞ 8⅝ STOK # 46V-KM 46V-KT 3⅜ 2⅛ 6⅝ 8⅝ himney onversion Kit Kits 46V-K, 46V-K, and 46V-K include: ap dapter and a Retro onnector. irectvent Pro x Termination ap and flex are sold separately. Use with x direct vent gas stoves. Use existing throughthe-ceiling, wood-stove metal chimney. Route the exhaust gases and intake air through the existing wood-stove metal chimney. 3⅜ 8⅝ 6⅝ STOK # 46V-K V-K V-K V-K FITS: 46V-K FITS: 46V-K FITS: SV 5-6 URTEH SV 6 URPLUS & 7-8 URTEH SV 7-8 URPLUS 6 SEURITY HIMNEY 8 SEURITY HIMNEY 7 & 8 URPLUS 6 METLESTOS 7 & 8 METLESTOS 8 MERIN METLS 6 JKES-EVNS 7 & 8 JKES-EVNS 8 IR-JET 6 HRT & OOLEY 7 & 8 HRT & OOLEY 8 METL-F 6 PRO JET 7 & 8 PRO JET 6 & 7 MERIN METLS Simpson ura-vent 166

3 irectvent Pro irect Vent Pipe Length esigned for appliances tested and listed for direct vent. Features a fully unitized twist-lock construction in both x and 5 x 8 vent sizes. Use of sealant is optional, unless specified by the appliance manufacturer. To calculate install length, subtract for each joint. No beads or hems. lack pipe lengths feature exterior laser-welded seams. SIZE GLVNIZE LK x V-06 46V-06 6 x V-09 46V-09 9 x V-12 46V x V-18 46V x V-24 46V-24 2 x V-36 46V x V-48 46V x V-60 46V x 8 58V-06 58V x 8 58V-09 58V x 8 58V-12 58V x 8 58V-18 58V x 8 58V-24 58V x 8 58V-36 58V x 8 58V-48 58V x 8 58V-60 58V Pipe Extension Use to add length to a straight length of irectvent Pro. 8 ½ pipe adds 3-7 of length, 16 pipe adds 3-14 ½ of length, when used with rigid sections of pipe. irect vent lengths feature a fully unitized, twist-lock construction. Use of sealant is optional, unless specified by the appliance manufacturer. vailable in black or galvalume exterior (both feature laser-welded outer wall seams). oes not fit irectvent GS pipe. SIZE GLVNIZE LK EXTENSION x V-08 46V x V-16 46V ½ 5 x 8 58V-08 58V x 8 58V-16 58V ½ 167 Simpson ura-vent

4 irect Vent irectvent Pro 45 Elbow Use to offset obstructions as needed. Fully unitized, twist-lock construction. Elbows swivel, allowing the lock to remain fully engaged while aligning to the desired direction. The angle will remain fixed at 45. SIZE GLVNIZE LK x V-E45 46V-E x 8 58V-E45 58V-E Elbow Use to offset obstructions as needed. Fully unitized, twist-lock construction. Elbows swivel, allowing the lock to remain fully engaged while aligning to the desired direction. The angle will remain fixed at 90. SIZE GLVNIZE LK x V-E90 46V-E x 8 58V-E90 58V-E Elbow Strap Use for supporting vent pipe between offsets. SIZE STOK # x V-ES x 8 58V-ES 8 17 eiling Support/ Wall Thimble over Use as a decorative cover for horizontal (through-wall) installations or for flat ceiling installations. Fits over the Wall Thimble face plate. omes with an insulation ring to reduce air infiltration where the pipe slips through the thimble. Painted black. SIZE STOK # x V x 8 58V ⅛ Simpson ura-vent 168

5 irectvent Pro irect Vent athedral eiling Support ox Use to pass through ceiling and support pipe. May be used on vaulted or flat ceilings. Painted black. Trim and clamp included. 1 SIZE STOK # x V-S x 8 58V-S Wall Thimble Provides a complete wall-pass-through and firestop. Use with Square horizontal ap only. May be required in anada. Refer to the appliance manufacturer s installation instructions for requirements. SIZE STOK # x V-WT x 8 58V-WT Wall Thimble - Small Provides a complete wall-pass-through and firestop. Use with Round horizontal ap and Sconce ap only. May be required in anada. Refer to the appliance manufacturer s installation instructions for requirements. SIZE STOK # x V-WTS x 8 58V-WTS Universal Wall Thimble 4 Provides a complete wall-pass-through and interior firestop. Features an adjustable sleeve for an exact fit. Eliminates visible trim on exterior or wall near cap. Sized to fit all Simpson ura-vent irectvent Pro s termination caps. SIZE STOK # x V-WTU x 8 58V-WTU Simpson ura-vent

6 irect Vent irectvent Pro Wall Firestop For horizontal (through-wall) installations. Refer to the appliance manufacturer s installation instructions for requirements. SIZE STOK # x V-WFS x 8 58V-WFS Vinyl Siding Standoff 1⅞ Use as a heat shield on structures with vinyl siding, or other temperature sensitive materials, to help prevent warping and or melting of the material. Use only on horizontal terminations and on any irregular surfaced siding (ie: ship lap siding, shake shingle siding) so cap is not imbedded in the siding. Sized for Square horizontal ap. SIZE STOK # x V-VSS x 8 58V-VSS Vinyl Siding Standoff Kit Use as a heat shield on structures with vinyl siding, or other temperature sensitive materials, to help prevent warping and or melting of the material. Use only on horizontal terminations and on any irregular surfaced siding (ie: ship lag siding, shake shingle siding) so cap is not imbedded in the siding. Kit includes 4-pieces; sized for Square horizontal ap only. Stainless steel (SS) and opper () available. SIZE STOK # x V-VSK x V-VSK-SS x V-VSK x 8 58V-VSK x 8 58V-VSK-SS x 8 58V-VSK Simpson ura-vent 170

7 irectvent Pro irect Vent Vinyl Siding Standoff Kit - Small Use as a heat shield on structures with vinyl siding, or other temperature sensitive materials, to help prevent warping and or melting of the material. Use only on horizontal terminations and on any irregular surfaced siding (ie: ship lag siding, shake shingle siding) so cap is not imbedded in the siding. Kit includes 4-pieces; sized for Sconce ap and Round horizontal ap only. Stainless steel (SS) and opper () available. SIZE STOK # x V-VSKS x V-VSKS-SS x V-VSKS ounter Flashing Prevents water intrusion into stucco-sided homes. llows the installer to apply siding material (ie: stucco, brick, etc) over the flanges up to the sides of the flashing for a water-tight seal. Kit includes 4-pieces; sized for Square horizontal ap only. SIZE STOK # x V-FK x V-FK-S x 8 58V-FK ounter Flashing - Small Prevents water intrusion into stucco-sided homes. llows the installer to apply siding material (ie: stucco, brick, etc) over the flanges up to the sides of the flashing for a water-tight seal. Kit includes 4-pieces; sized for x Sconce ap and Round horizontal ap only. lso available in stainless steel (S). SIZE STOK # x V-FKS x V-FKS-S eiling Firestop Required for multi-story vertical installations at the second floor and any subsequent floors. x style may vary. SIZE STOK # x V-FS x 8 58V-FS Simpson ura-vent

8 irect Vent irectvent Pro ttic Insulation Shield Ø6¾ & Ø8 Ø6¾ djusts Required for installations that pass through an attic to prevent insulation and debris from accumulating near the vent. Provides 1 clearance to combustibles. SIZE STOK # x V-IS 5 x 8 58V-IS 7 3 / /16 Wall Strap Use to support vent pipe. Provides 1 clearance. Recommend installing Wall Straps at 4-foot intervals on vertical runs. 1 SIZE STOK # x V-WS x 8 58V-WS 8 Restrictor isk Use only in accordance with specific appliance manufacturer s installation instructions to restrict incoming combustion air. 5¼ 49/16 SIZE STOK # x V-R x 8 58V-R 7 6 djustable Roof Flashing Use to weather proof the penetration of vent pipe through the roof. Storm ollar required. Select roof flashing based on pitch of roof. For pitches of 0/12-6/12. Made of galvalume. 6 SIZE STOK # x V-F x 8 58V-F Simpson ura-vent 172

9 irectvent Pro irect Vent Steep Roof Flashing Use to weather proof the penetration of vent pipe through the roof. Storm ollar required. For roof pitches of Made of galvalume. 6 SIZE STOK # x V-F x 8 58V-F Flat Roof Flashing Use to weather proof the penetration of vent pipe through the roof. Storm ollar required. Use on flat roofs, chase enclosures, or masonry chimney. Made of galvalume. SIZE STOK # x V-FF x 8 58V-FF S Flashings Use with metal or tile roofs. vailable in sizes x and 5 x 8, in 0/12-6/12 (shown) and 7/12-12/12 styles. Made of dead soft aluminum. Refer to roof flashings tables (previous page) for dimensions. SIZE STYLE STOK # x /12-6/12 46V-F6S x /12-12/12 46V-F12S 5 x 8 0/12-6/12 58V-F6S 5 x 8 7/12-12/12 58V-F12S Storm ollar Use to maintain a weather tight resistant seal between the pipe and the flashing. SIZE STOK # x V-S x 8 58V-S Simpson ura-vent

10 irect Vent irectvent Pro Round horizontal Termination ap Use for through-the-wall terminations. heck installation instructions for restrictions on horizontal cap terminations, such as minimum distance from windows and doors. vailable in aluminum only. heck with appliance manufacturer for approval. SIZE STOK # x V-HR 11 5 ¾ x 8 58V-HR 11 5 ¾ Sconce Termination ap Use for horizontal through-the-wall terminations. heck installation instructions for restrictions on horizontal cap terminations, such as minimum distance from windows and doors. vailable in aluminum, stainless steel (S), and copper (). heck with appliance manufacturer for approval. Patented. SIZE STOK # x V-HS 11" " x V-HS-S 11" " x V-HS " x 8 58V-HS " x 8 58V-HS-S " x 8 58V-HS " high-wind Sconce Termination ap Use for horizontal through-the-wall terminations. Provides improved performance in high wind conditions. heck installation instructions for restrictions on horizontal cap terminations, such as minimum distance from windows and doors. vailable in aluminum, stainless steel (S), and copper (). heck with appliance manufacturer for approval. Patented. HOT SIZE STOK # x V-HSH 11" " x V-HSH-S 11" " x V-HSH " x 8 58V-HSH " x 8 58V-HSH-S " x 8 58V-HSH " Simpson ura-vent 174

11 irectvent Pro irect Vent Square horizontal Termination ap Use for standard and high-wind through-the-wall terminations. heck installation instructions for restrictions on horizontal cap terminations, such as minimum distance from windows and doors. vailable in aluminum, stainless steel (S), and copper (). SIZE STOK # x V-H x V-H-S x V-H x 8 58V-H x 8 58V-H-S x 8 58V-H Snorkel Termination ap Use for horizontal through-the-wall terminations when a vertical rise is desired in the system to meet appliance manufacturer recommended minimum heights. o not enclose in the wall or install below grade. Patented. SIZE STOK # x V-SNK x V-SNK x 8 58V-SNK x 8 58V-SNK horizontal Windguard Use with through-the-wall termination cap where high winds are present. lso use as a safety heat shield to prevent children or others from coming into contact with the vent termination cap. Fits both x and 5 x 8 terminations ½ STOK # 46V-WG 175 Simpson ura-vent

12 irect Vent irectvent Pro high-wind Termination ap Use for horizontal through-the-wall terminations. Provides improved performance in high wind conditions. For vertical terminations only. vailable in aluminum. SIZE STOK # x V-VH x 8 58V-VH Low-Profile Termination ap Use for vertical terminations only. heck the appliance manufacturer s instructions to determine which caps are approved for use with their appliance. vailable in aluminum and stainless steel (S). SIZE STOK # x V-V x V-V-S x 8 58V-V x 8 58V-V-S Extended Vertical Termination ap Use in extremely cold climates. Similar to the Low Profile Termination ap but taller in overall height to separate the air intake vents from the exhaust area. Refer to the appliance manufacturer s installation instructions for requirements. vailable in aluminum. SIZE STOK # x V-VE x 8 58V-VE luminum Flex Length Use 3 flex with the co-linear system and flex with onversion Kits. See uraflex L section for more information. Flexible.010 thick 2-ply aluminum. Pricing for luminum Flex Length are listed under uraflex L. SIZE LENGTh STOK # Simpson ura-vent 176

13 irectvent Pro irect Vent Flex oupling Use to join flex liner sections together. Pricing for luminum Flex Length are listed under uraflex L. 3 SIZE STOK # o-xial To o-linear ppliance onnector Use o-linear dapter for stoves with X co-axial outlets. Refer to appliance manufacturer s installation instructions for approval. Uses 3 aluminum flex for both intake and exhaust. SIZE ONNETOR STOK # x STNR 46V-GL x TRVIS INUSTRIES 46V-TL x VERMONT STINGS 46V-VL ppliance dapter ttaches to appliance outlet allowing pipe to easily connect or disconnect. For Vermont astings appliances SIZE STOK # x V-P o-linear Flex onnector ¼ Use as a flex connector with inserts with 3 co-linear intake and exhaust ports. SIZE STOK # x V-F Simpson ura-vent

DirectVent Pro. Simpson Dura-Vent Engineered Excellence

DirectVent Pro. Simpson Dura-Vent Engineered Excellence irectvent Pro Simpson ura-vent Engineered Excellence pplications irectvent Pro is a unitized, coaxial venting system designed for use with direct vent gas or propane stoves, heaters, and fireplaces. Materials

More information

Simpson Dura-Vent Engineered Excellence

Simpson Dura-Vent Engineered Excellence DuraPlus Simpson Dura-Vent Engineered Excellence pplications DuraPlus himney is a triple-wall, all-fuel chimney for use with wood stoves, fireplaces, furnaces, boilers, stoves, ranges, water heaters, or

More information

DuraPlus. All-fuel, triple-wall chimney system. UL 103 HT.

DuraPlus. All-fuel, triple-wall chimney system. UL 103 HT. DuraPlus ll-fuel, triple-wall chimney system. UL 103 HT. Specifications pplications DuraPlus himney is a triple-wall, all-fuel chimney for use with wood stoves, fireplaces, furnaces, boilers, stoves, ranges,

More information

Gas venting. Table of Contents. DirectVent 4 x 6 5/ DirectVent 5 x DirectVent Pro Kits DirectVent CVS... 7

Gas venting. Table of Contents. DirectVent 4 x 6 5/ DirectVent 5 x DirectVent Pro Kits DirectVent CVS... 7 Gas venting DIRECT VENT PRO CVS CHIMNEY LINER B-VENT CO-LINEAR CAPS Table of Contents DirectVent 4 x 6 5/8... 2 DirectVent 5 x 8... 4 DirectVent Pro Kits... 6 DirectVent CVS... 7 DirectVent Liner Kits...

More information

Simpson Dura-Vent Engineered Excellence

Simpson Dura-Vent Engineered Excellence DuraLiner Simpson Dura-Vent Engineered Excellence pplications Materials and onstruction DuraLiner DuraLiner ensures safe and efficient venting of heating appliances, while protecting the masonry chimney

More information

DuraLiner. Insulated, double-wall masonry relining. UL 1777, ULC S635, and ULC S640.

DuraLiner. Insulated, double-wall masonry relining. UL 1777, ULC S635, and ULC S640. DuraLiner Insulated, double-wall masonry relining. UL 1777, ULC S635, and ULC S640. Specifications pplications DuraLiner is a high-temperature, insulated double-wall masonry relining system for use with

More information

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8. Model P36-NG10 P36-LP10 P36E-NG10 P36E-LP10 Fuel Type Natural Gas Propane Natural Gas Propane Gas Fireplaces P36-10 / P36E-10 Gas Fireplace Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa)

More information

DVL. DuraBlack. Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC S641.

DVL. DuraBlack. Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC S641. Duralack Single-wall interior stovepipe for connecting woodstoves to chimney. Specifications DVL pplications

More information

Installation Instructions. Venting System For Direct Vent Gas Stoves and Fireplaces. DirectVent Pro

Installation Instructions. Venting System For Direct Vent Gas Stoves and Fireplaces. DirectVent Pro Installation Instructions Venting System For Direct Vent Gas Stoves and Fireplaces DirectVent Pro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE

More information

Installation Instructions. Venting System For Direct Vent Gas Stoves and Fireplaces. DirectVent Pro

Installation Instructions. Venting System For Direct Vent Gas Stoves and Fireplaces. DirectVent Pro Installation Instructions Venting System For Direct Vent Gas Stoves and Fireplaces DirectVent Pro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE

More information

female pipe. A Wall Support must be installed just above the tee and at least every 8 feet thereafter. If the pipe is to be run through a roof overhang then a Flashing, Storm Collar and Vertical Rain Cap

More information

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth 28-15/16 (735mm) Model P36D-NG10 P36D-LP10 Fuel Type Natural Gas Propane Gas Fireplaces Minimum Supply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.25 kpa) 3.8 W.C. (0.95 kpa) 1.1

More information

Technical and Dimensional Data. Saf-T Vent SC

Technical and Dimensional Data. Saf-T Vent SC Technical and Dimensional Data Saf-T Vent SC 3"/5" & 4"/7" Concentric Reduced Clearance Double Wall for Special Gas Vent and/or Sealed Combustion Systems Copyright 2003 Saf-T Vent is a registered trademark

More information

Regency Horizon HZ30E Gas Fireplace

Regency Horizon HZ30E Gas Fireplace Specifications: Framing Dimensions: Model HZ3E-NG HZ3E-LP Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High Approved Venting Systems Flex Vent Systems: Rigid Pipe Vent

More information

B36XTCE Gas Fireplace

B36XTCE Gas Fireplace Model B3XTCE-NG1 B3XTCE-LP1 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C./C.E. (1.5 kpa) 11 W.C./C.E. (.7 kpa) Manifold Pressure - High 3.5 W.C./C.E. (.7 kpa) 1 W.C./C.E. (.9 kpa) Manifold

More information

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE Model P33-NG10 P33-LP10 P33E-NG10 P33E-LP10 Fuel Type Natural Gas Propane Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 11 W.C. (2.74 kpa) 5 W.C. (1.25 kpa) 11 W.C. (2.74 kpa) Manifold

More information

P36 / P36E Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.35 kw)

P36 / P36E Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.35 kw) P36 / P36E Gas Fireplace Model P36-NG10 P36-LP10 P36E-NG10 P36E-LP10 Fuel Type Natural Gas Propane Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) 5 W.C. (1.25 kpa) 11

More information

P36 - P36D Zero Clearance Direct Vent Gas Fireplace. 12 W.C. (3.00 kpa) 11 W.C. (2.74 kpa) 2.9 W.C. (0.72 kpa) 15,000 BTU/h (3.

P36 - P36D Zero Clearance Direct Vent Gas Fireplace. 12 W.C. (3.00 kpa) 11 W.C. (2.74 kpa) 2.9 W.C. (0.72 kpa) 15,000 BTU/h (3. P36 - P36D Zero Clearance Direct Vent Gas Fireplace Model P36-NG4 P36-LP4 P36D-NG1 P36D-LP1 Fuel Type Natural Gas Propane Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3. kpa)

More information

B41XTCE Gas Fireplace

B41XTCE Gas Fireplace B1XTCE Gas Fireplace Model B1XTCE-NG1 B1XTCE-LP1 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C./C.E. (1.5 kpa) 11 W.C./C.E. (.7 kpa) Manifold Pressure - High 3.5 W.C./C.E. (.7 kpa) 1 W.C./C.E.

More information

Contemporary Collection

Contemporary Collection HZ5E Gas Fireplace Model HZE-NG HZ5E-LP Fuel Type Natural Gas Propane Gas Minimum Supply Pressure 5 W.C.(1.5 kpa) 1 W.C. (.9 kpa) Manifold Pressure - High 3.5 W.C. (.7 kpa) 1 W.C. (.9 kpa) Manifold Pressure

More information

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635. DuraFlex Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635. Specifications DuraFlex SW Applications DuraFlex SW smooth wall flexible relining for masonry chimney. Use with gas,

More information

Gas Fireplaces. B41XTE-10 Gas Fireplace. Framing Dimensions: Unit Dimensions: Non-Combustible 1012mm Requirements: V Opening for gas connection

Gas Fireplaces. B41XTE-10 Gas Fireplace. Framing Dimensions: Unit Dimensions: Non-Combustible 1012mm Requirements: V Opening for gas connection 1XTE-1 Gas Fireplace Model 1XTE-NG1 1XTE-LP1 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.5 kpa) 3.5 W.C. (.7 kpa) 1. W.C. (. kpa)

More information

Dur aflex stainless steel

Dur aflex stainless steel Dur aflex stainless steel Simpson Dura-Vent Engineered Excellence DuraFlex SW DuraFlex SW is a smooth inner-wall, flexible stainless steel chimney liner. The smooth inner wall provides for no output reduction

More information

Light Stainless Flexible Liner

Light Stainless Flexible Liner Light Stainless Flexible Liner Dalsin Line light flexible liner is listed for chimney relining and is suitable for wood, pellet, gas, oil, and coal applications. This liner is manufactured using.006 thick

More information

Gas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth

Gas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth P33 Zero Clearance Direct Vent Gas Fireplace P33 WITH THE FLUSH OR BAY FRONT Model P33-NG4 P33-LP4 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) Manifold Pressure

More information

DIRECT-TEMP SELKIRK DIRECT VENT SYSTEM

DIRECT-TEMP SELKIRK DIRECT VENT SYSTEM C I NT ER T EK Wa r noc k CM He r sey US U L LISTED CAUTION: WEAR GLOES WHILE HANDLING SHEET METAL PARTS TO AOID PERSONAL INJURY. SHARP EDGES OR PROJECTIONS CAN CUT YOU. Selkirk DIRECT-TEMP Direct ent

More information

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635. DuraFlex Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635. Specifications DuraFlex Pro Applications DuraFlex Pro ultra flexible relining for masonry chimney. Use with gas, wood

More information

APPLICATION AND LISTING

APPLICATION AND LISTING DURALINER (SDL) 6"-8" DIAMETER (ROUND & OVAL) INSTALLATION INSTRUCTIONS MH14420 CMH1329 THESE INSTALLATION AND OPERATION INSTRUCTIONS COVER DURALINER MASONRY RELINING SYSTEM A MAJOR CAUSE OF CHIMNEY RELATED

More information

PelletVent Cornvent. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

PelletVent Cornvent. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y Installation Instructions Venting System For Pellet and Corn Stoves PelletVent Cornvent C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y A MAJOR CAUSE OF VENT RELATED

More information

Installation Instructions

Installation Instructions Installation Instructions SAVE THESE INSTRUCTIONS Please read this entire manual before you install and use your room heater. Failure to follow instructions may result in property damage, bodily injury,

More information

PolyPro Polypropylene venting products for high-efficiency condensing appliance installations. Listed to ULC-S636.

PolyPro Polypropylene venting products for high-efficiency condensing appliance installations. Listed to ULC-S636. PolyPro Polypropylene venting products for high-efficiency condensing appliance installations. Listed to ULC-S636. Specifications pplications PolyPro is a polypropylene vent pipe for use with NSI Category

More information

Ventinox. Welded, flexible and rigid relining for masonry chimney. UL 1777, ULC S635 and ULC S640.

Ventinox. Welded, flexible and rigid relining for masonry chimney. UL 1777, ULC S635 and ULC S640. Ventinox Welded, flexible and rigid relining for masonry chimney. UL 1777, ULC S635 and ULC S640. Specifications Applications VFT flexible liners are used for upgrading or restoring masonry chimneys that

More information

INSTALLATION INSTRUCTIONS OPERATION AND MAINTENANCE MANUAL Models event SD, event, Event Plus, and event Plus2 (Condensing Boiler Systems)

INSTALLATION INSTRUCTIONS OPERATION AND MAINTENANCE MANUAL Models event SD, event, Event Plus, and event Plus2 (Condensing Boiler Systems) C US INSTALLATION INSTRUCTIONS OPERATION AND MAINTENANCE MANUAL Models event SD, event, Event Plus, and event Plus2 (Condensing Boiler Systems) A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN

More information

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS ENCLOSURE MODEL 90566400 FOR INSERT MODEL 5660NA And ENCLOSURE MODEL 90566000 FOR INSERT MODEL 5660 STANDARD KEEP THESE INSTRUCTIONS FOR FUTURE USE

More information

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section ) 8-1200. International Residential Code. ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section 6-9-40) NOTE-This article

More information

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of

More information

WeatherSmart Air Barrier Installation Guide

WeatherSmart Air Barrier Installation Guide WeatherSmart Air Barrier Installation Guide 1 The intent of this document is to provide a guide for the installation of WeatherSmart as both a Weather Resistive Barrier (W.R.B.) and an Air Barrier Material

More information

TYPICAL ROOF CONDITION LAYOUT

TYPICAL ROOF CONDITION LAYOUT FIXED POINTS TYPICAL ROOF CONDITION LAYOUT 15 17 9 16 29 12 14 11 3 7 35 20 6 23 30 31 24 13 18 Typical Roof Condition Layout... 1 Low Eave Isometric View - Fixed/ Floating... 2 Low Eave Section - Fixed/

More information

Online Update 10/2011 Current Print Version L820 1/2011

Online Update 10/2011 Current Print Version L820 1/2011 Online Update 10/2011 Current Print Version L820 1/2011 Product Catalog 2011-2012 eing Green, eing Responsible. DuraVent looks for feasible ways of doing business in an ecologically sound way. DuraVent

More information

ICC - Model VIP+ Positive Pressure Chimney System and Grease Duct

ICC - Model VIP+ Positive Pressure Chimney System and Grease Duct Scope and Recommendations ICC - Model VIP+ Positive Pressure Chimney System and Grease Duct INSTALLATION AND MAINTENANCE INSTRUCTIONS The ICC Model VIP+ is a double wall construction listed venting system

More information

Installation Instructions. Pellet-fuel venting system. PelletVent

Installation Instructions. Pellet-fuel venting system. PelletVent Installation Instructions Pellet-fuel venting system. PelletVent A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST

More information

ROOF MOUNT KIT OWNERS MANUAL

ROOF MOUNT KIT OWNERS MANUAL ROOF MOUNT KIT OWNERS MANUAL Made in the USA by: Southwest Windpower, Inc. 1801 W. Route 66 Flagstaff, Arizona 86001 Phone: (928) 779-9463 Fax: (928) 779-1485 E-mail: info@windenergy.com Web: www.windenergy.com

More information

Roof Replacement. Notes: T-1 (Title Page) 709 Bull Street Columbia, South Carolina. University of South Carolina. Callcott Social Science

Roof Replacement. Notes: T-1 (Title Page) 709 Bull Street Columbia, South Carolina. University of South Carolina. Callcott Social Science Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details S1.0 Safety Anchor Plan Building 709 Bull Street Columbia, 1 10/13 T-1 (Title Page)

More information

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS ULEB 150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS WARNING: THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F. TO ENSURE SAFETY THIS

More information

ROOF MOUNT KIT OWNERS MANUAL

ROOF MOUNT KIT OWNERS MANUAL ROOF MOUNT KIT OWNERS MANUAL Made in the USA by: Primus Wind Power, Inc. 938 Quail St. Lakewood, CO 80215 Phone: (303) 242-5820 www.primuswindpower.com AIR is a trademark of Primus Wind Power, Inc. ROOF

More information

Z-Vent Model SVE Series III

Z-Vent Model SVE Series III Special Stainless Steel Venting System for Gas Burning Appliances Category I, II, III, & IV Tested and Listed By Underwriters Laboratories Inc. UL 1738 & BH636 Note the following before installation of

More information

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS 150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS WARNING: THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F. TO ENSURE SAFETY THIS FLUE

More information

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS 150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS WARNING: THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F. TO ENSURE SAFETY THIS FLUE

More information

SECURE STACK PRO POSITIVE PRESSURE SYSTEMS MODELS

SECURE STACK PRO POSITIVE PRESSURE SYSTEMS MODELS SECURITY CHIMNEYS INTERNATIONAL SECURE STACK PRO POSITIVE PRESSURE SYSTEMS MODELS Boiler Breeching and Stack Generator Engine Exhaust Fume Venting Fireplace Venting CAX1 1 INCH AIR INSULATED CIX1 1 INCH

More information

DIRECT-TEMP SELKIRK DIRECT VENT SYSTEM

DIRECT-TEMP SELKIRK DIRECT VENT SYSTEM C I NTERTEK War nock CM Her sey US U L LISTED CAUTION: WEAR GLOES WHILE HANDLING SHEET METAL PARTS TO AOID PERSONAL INJURY. SHARP EDGES OR PROJECTIONS CAN CUT YOU. Selkirk DIRECT-TEMP Direct ent system

More information

O B R O U N D G R E A S E D U C T

O B R O U N D G R E A S E D U C T TM O B R O U N D G R E A S E D U C T SlimVent OBROUND GREASE DUCT SlimVent is a UL Classified zero-clearance grease duct system with the space saving profile of a field fabricated rectangular product.

More information

PROJECT: PREPARED BY: PREPARED FOR: Boiler Breeching and Stack Generator Engine Exhaust Fume Venting Fireplace Venting

PROJECT: PREPARED BY: PREPARED FOR: Boiler Breeching and Stack Generator Engine Exhaust Fume Venting Fireplace Venting M&G DURAVENT DURASTACK PRO POSITIVE PRESSURE SYSTEMS MODELS DAS1 1 INCH AIR INSULATED DIS1 1 INCH CERAMIC FIBER INSULATED DIS2 2 INCH CERAMIC FIBER INSULATED DIS4 4 INCH CERAMIC FIBER INSULATED DCL SINGLE

More information

CHIMNEYS AND FIREPLACES

CHIMNEYS AND FIREPLACES CHAPTER 10 CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY FIREPLACES R1001.1 General. Masonry fireplaces shall be constructed in accordance with this section and the applicable provisions of Chapters 3

More information

Chimney Lining Systems

Chimney Lining Systems R Chimney Lining Systems Gas or Propane Fired Appliances Table of Contents 1. General Instructions and Warnings U.L. and Manufacturers Specifi cations...2 2. Types of Liner Systems...3 3. FLEXJET Installation

More information

Installation Instructions

Installation Instructions Installation Instructions Flue Gas System Basic Kit GA-K - Chimney Flue Gas System for GB125 Oil Condensing Boiler For trained and certified installers Please read carefully prior to installation. 6 720

More information

DIRECT-TEMP METALBESTOS DIRECT VENT SYSTEM

DIRECT-TEMP METALBESTOS DIRECT VENT SYSTEM C Wa I NT ERT EK r nock CM He r sey US U L LISTED CAUTION: WEAR GLOES WHILE HANDLING SHEET METAL PARTS TO AOID PERSONAL INJURY. SHARP EDGES OR PROJECTIONS CAN CUT YOU. Selkirk Metalbestos DIRECT-TEMP Direct

More information

GAF EnergyGuard Polyiso Wall Sheathing

GAF EnergyGuard Polyiso Wall Sheathing From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include:

More information

SECTION PLUMBING PIPING SYSTEM

SECTION PLUMBING PIPING SYSTEM SECTION 15410 - PLUMBING PIPING SYSTEM PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, are a part of this Section. 1.02 SUMMARY

More information

Chimney and Fireplace Inspection Report

Chimney and Fireplace Inspection Report Chimney and Fireplace Inspection Report 91406 Inspection prepared for: Mr. and Mrs. Client Inspector: Greg Butler 27943 Seco Canyon Road, 560, Santa Clarita, CA 91350 NOTICE TO THIRD PARTIES: This report

More information

SAFETY PRECAUTIONS. Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer.

SAFETY PRECAUTIONS. Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer. SAFETY PRECAUTIONS Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer. Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter

More information

Gas Fireplaces. B36XTE Gas Fireplace. Unit Dimensions with Vignette: Model B36XTE-NG10 B36XTE-LP10 M O S S. V Opening for gas connection

Gas Fireplaces. B36XTE Gas Fireplace. Unit Dimensions with Vignette: Model B36XTE-NG10 B36XTE-LP10 M O S S. V Opening for gas connection Model B36XTE-NG10 B36XTE-LP10 Fuel Type Natural Gas Propane Gas Fireplaces B36XTE Gas Fireplace Minimum upply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.5 kpa) 3.5 W.C. (0.87 kpa)

More information

InoxSabiana 25 Flues. Stainless Steel Double Wall

InoxSabiana 25 Flues. Stainless Steel Double Wall Cert. n 0545/5 Flues Stainless Steel Double Wall Introduction and main constructional characteristics Double Wall, Stainless Steel Flues The is the result of innovative development based on over 0 years

More information

SECTION DUCTS PART 1 GENERAL 1.01 SUMMARY

SECTION DUCTS PART 1 GENERAL 1.01 SUMMARY 1 1 1 1 1 1 1 1 0 1 0 1 SECTION 1 DUCTS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Duct Materials.. Insulated flexible ducts.. Single wall spiral round ducts.. Ductwork fabrication.. Duct cleaning.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Boiler and Engine Exhaust Chimney Systems Grease Duct Systems (CIX only) Double Wall Construction Positive Pressure Chimney Systems P/N 506065-03 REV. N 02/2015 MODELS CIX / CAX

More information

CHIMNEYS AND FIREPLACES

CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY FIREPLACES R1001.1 General. Masonry fireplaces shall be constructed in accordance with this section and the applicable provisions of Chapters 3 and 4. R1001.2 Footings and foundations.

More information

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights 1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights These 1 Exam Prep tabs are based on the 2012 Sheet Metal and Air Conditioning Contractors' National Association, Inc., seventh edition.

More information

Natrona County Development Department 200 North Center Street, Room 205 Casper, WY Phone: Fax:

Natrona County Development Department 200 North Center Street, Room 205 Casper, WY Phone: Fax: Natrona County Development Department 200 North Center Street, Room 205 Casper, WY 82601 Phone: 307-235-9435 Fax: 307-235-9436 The purpose of the Natrona County Development Department is to provide necessary

More information

Rediflow Concrete Gas Flue System

Rediflow Concrete Gas Flue System Rediflow Concrete Gas Flue System Rediflow Concrete Gas Flue System Rediflow the complete gas flue block system Red Bank s range of Rediflow pre-cast concrete gas flue block system manufactured to BS EN

More information

Flue gas systems for oil and gas condensing boilers. Flue gas kit DN60 rigid in the duct. Accessories DN60 (additionally available to gas flue kit)

Flue gas systems for oil and gas condensing boilers. Flue gas kit DN60 rigid in the duct. Accessories DN60 (additionally available to gas flue kit) Flue gas kit DN60 rigid in the duct 100193 Flue gas kit No Outlet set plastic 1 x Set 100193 39.10 (Quantities in the image differ from the set) 1003253 1001938 Spacer set * ( pieces) Top inspection opening

More information

Midtherm Vitrelux flue pipe is available from stock, in the following standard colours and diameters, unless otherwise stated:

Midtherm Vitrelux flue pipe is available from stock, in the following standard colours and diameters, unless otherwise stated: Introduction Midtherm Flue Systems Limited is an independent ritish manufacturing company producing a wide range of flue and chimney products, along with associated components and services. Established

More information

Installation Instructions. High-Temperature, Factory Insulated Double-Wall Masonry Relining system 5" Round 6", 8" Round and Oval.

Installation Instructions. High-Temperature, Factory Insulated Double-Wall Masonry Relining system 5 Round 6, 8 Round and Oval. Installation Instructions High-Temperature, Factory Insulated Double-Wall Masonry Relining system 5" Round 6", 8" Round and Oval DuraLiner A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED

More information

Installation Instructions

Installation Instructions Installation Instructions Flue Gas System Basic Kit HT-K - Horizontal Flue Gas System For GB125 Oil Condensing Boiler For trained and certified Installers Please read carefully prior to installation. 6

More information

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED. WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED. Build walls and ceilings with a strong base, sturdy reinforcements and much more with Phillips extensive line of high quality products. As a single source

More information

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS SECTION 16711-27 05 28.33 PART 1 - GENERAL 1.01 SUMMARY A. This section includes Labor, materials and equipment necessary to complete the installation required for the items specified under this Section,

More information

EPV Pellet Vent Pellet Stove Venting System Installation Instructions

EPV Pellet Vent Pellet Stove Venting System Installation Instructions EPV Pellet Vent Pellet Stove Venting System Installation Instructions A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE

More information

HIGH EFFICIENCY POSITIVE PRESSURE VENTING SYSTEMS FOR CONDENSING APPLIANCES, CATEGORIES II, III AND IV Single & Double Wall Construction

HIGH EFFICIENCY POSITIVE PRESSURE VENTING SYSTEMS FOR CONDENSING APPLIANCES, CATEGORIES II, III AND IV Single & Double Wall Construction HIGH EFFICIENCY POSITIVE PRESSURE VENTING SYSTEMS FOR CONDENSING APPLIANCES, CATEGORIES II, III AND IV Single & Double Wall Construction Models HEP HEPL HEPL2 28 KJ This symbol shows that CHEMINÉE LINING.E

More information

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS PART 1 - GENERAL 01.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification sections, apply to work of this Section.

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208 Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details D-3 Roof Details M-1 Mechanical - Roof Plan M-2 Mechanical - Details Roof Key Plan

More information

Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual

Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual Please see IB series product installation guide for details of installing the gas fire into this preformed metal cavity. Important: The appliance

More information

Standard practice for installing cellulose building insulation

Standard practice for installing cellulose building insulation TECHNICAL BULLETIN Standard practice for installing cellulose building insulation Cellulose insulation can be installed in attics, walls, ceilings, floors, and other building assemblies using a variety

More information

Mechanically Fasten Duct Sections. Code Reference: 2013 Title 24, Part 6 Standards 120.4(a) Sealed Openings. Drawbands

Mechanically Fasten Duct Sections. Code Reference: 2013 Title 24, Part 6 Standards 120.4(a) Sealed Openings. Drawbands DUCTS - SEALING R-H-DS1 Mechanically Fasten Duct Sections Sections of metal duct should be mechanically fastened together after taping seams with UL 181 duct tape. Use sheet metal screws for rigid duct

More information

SUBMITTAL RECORD. Material Selection FLUE (INNER WALL) CASING (OUTER WALL) GALVALUME

SUBMITTAL RECORD. Material Selection FLUE (INNER WALL) CASING (OUTER WALL) GALVALUME SUBMITTAL RECORD UL 1978 - Grease Duct Professional Series Kitchen Ventilation DCL Single Wall DAS1 1-inch Air Insulated DIS1 1-inch Insulated (AES WOOL) DIS2 2-inch Insulated (AES WOOL) DIS4 4-inch Insulated

More information

Installation Instructions. Converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent System. DirectVent Pro

Installation Instructions. Converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent System. DirectVent Pro Installation Instructions Converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent System DirectVent Pro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of

More information

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210) Quality Inspection 8618 London Heights San Antonio, TX 78254 Phone: (210) 240-0476 PRE DRYWALL INSPECTION REPORT Prepared For: DELETED (Name of Client) Concerning: DELETED, San Antonio, TX 78258 (Address

More information

Thimbles and Roof Jacks

Thimbles and Roof Jacks Industrial Silencer, Heat Recovery and Catalytic Specialists Maxim Silencers Thimbles and Roof Jacks Installation and Operation Manual NOTICE The instructions herein must be expressly carried out in order

More information

Concentric Vent/Air System Supplement

Concentric Vent/Air System Supplement Concentric Vent/Air System Supplement This document is intended to be used by a qualified heating contractor or service technician. Read all instructions within this document and within the CHAL- LENGER

More information

SELECT APPROPRIATE SECTIONS FOR BELOW; DELETE OTHERS

SELECT APPROPRIATE SECTIONS FOR BELOW; DELETE OTHERS Master Specifications 03440-1 SECTION 03440 REINFORCED AUTOCLAVED AERATED CONCRETE PANELS Date: 04-19-07 SECTION REQUIRES EDITOR TO MAKE SELECTIONS - GENERALLY SELECTIONS ARE PRECEDED BY **. SPEC EDITOR

More information

Architect & Builder s Guide. ORTAL Heating Systems Ltd.

Architect & Builder s Guide. ORTAL Heating Systems Ltd. Architect & Builder s Guide ORTAL Heating Systems Ltd. Welcome to ORTAL and ORTAL USA. ORTAL, providing heating solutions for over 25 years, is well known for its wide selection of modern gas fireplaces,

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES

RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES Prepared By Office of State Fire Marshal Maine Office of Energy Resources 52 State House Station 55 Capital Street Augusta, ME 04333 Augusta,

More information

Spec-Tech-Sales September 15, 2014

Spec-Tech-Sales September 15, 2014 Page 1 of 6 Spec-Tech-Sales September 15, 2014 Integrated Boiler Room Solutions Commercial Technical Sales and Service For the Rocky Mountain Region 14652 West Vassar Drive Lakewood, CO 80228 Colorado

More information

Installation Manual Installation and Fireplace Setup

Installation Manual Installation and Fireplace Setup Installation Manual Installation and Fireplace Setup INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. NOTICE: DO NOT discard this

More information

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco

More information

Property Inspection Checklist

Property Inspection Checklist Property Inspection Checklist Use a checklist like this to make sure that you are looking at all parts of the house. Check off those items that are in good condition and make notes about those that are

More information

Masonry Thimble Chimney Serving Appliance

Masonry Thimble Chimney Serving Appliance Job #3097931 Masonry Thimble Chimney Serving Appliance Customer Name Location Address Location of the appliance in the home - Appliance Information 1A What type of appliance is installed? Stove 1B What

More information

Installation Instructions

Installation Instructions InnoFlue Single Wall, Flex, Concentric Vent System The installation instructions should be kept with the appliance for maintenance. Examine all components for possible shipping damage prior to installation.

More information

CONTINUOUS VENTILATORS

CONTINUOUS VENTILATORS CONTINUOUS VENTILATORS used on metal roofing systems roofs conform to high standards and specifications which have been developed, tested and proven over many years. They provide an excellent value for

More information

Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood

Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood Please Note: This checklist should not be relied upon as a home inspection report, nor should it be considered a substitute for a home inspection. This list is representative, but NOT exhaustive. If you

More information