2 irectvent Pro Simpson ura-vent Engineered Excellence pplications irectvent Pro is a unitized, coaxial venting system designed for use with direct vent gas or propane stoves, heaters, and fireplaces. Materials and onstruction.020 aluminum inner wall..018 galvanized steel outer wall. Painted outer walls made of laser-welded.018 galvalume steel. Outer pipe brings combustion air to the appliance. Inner pipe exhausts flue gases to the outside. Gaskets or sealants not required (unless specified by the appliance manufacturer). irectvent Pro Stunning design and Engineered Excellence utilizing state-of-the art manufacturing. irectvent Pro features tight inner connections for superb performance, with no gaskets or sealants required (unless specified by the appliance manufacturer). ll black pipe lengths, pipe extensions, and elbows feature laser-welded outer wall seams for a sleek finish. Low-profile locks and no hems or beads allow for a beautiful product that looks elegant in any interior. Engineered Excellence with innovation and style...irectvent Pro. Simpson ura-vent's direct vent is specified exclusively by nearly every major stove and fireplace manufacturer in the U.S. and anada, with the largest choice of termination caps for direct vent available. learances Specified by the appliance manufacturer. iameters 4 x 6 8 and x 8. Listings irectvent Pro, in combination with the gas appliance, has been tested and listed as a decorative gas appliance system or as a direct vent heater system by a major testing agency, such as UL, S, Warnock Hersey, or OMNI. Limited Lifetime Warranty ll irectvent Pro components are compatible with irectvent GS stock, except for the irectvent Pro Pipe Extensions. warranty Limited Lifetime guarantee 130
3 HOT irectvent Pro irect Vent Typical Installations 1 Installation Key 1 Vertical Termination ap 9 90 Elbow Storm ollar 10 Horizontal Termination ap (see listed caps for choices) 3 Flashing 11 Snorkel Termination ap athedral eiling Support ox 12 himney Liner Termination Kit Pipe 13 3 Flex 6 4 Elbow 14 o-xial to o-linear onnector lass himney onversion Kit 1 Masonry himney onversion Kit 8 4 Flex 16 Elbow Strap Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation. athedral eiling Stove Installation Masonry himney onversion Elbow 7 Wall Thimble over or Wall Thimble Sconce Termination ap 6 Straight Pipe Length Fireplace Vertical Termination Metal himney onversion Stove with Snorkel Horizontal Termination o-linear Insert Stove Horizontal Termination 131 Simpson ura-vent
4 irect Vent irectvent Pro Planning Your Installation For vertical gas stove installations, measure the height from the stove outlet to the ceiling to determine the length of black pipe required. Select a ceiling support/wall thimble cover or a cathedral ceiling support box. To determine the length of galvanized pipe required, measure the ceiling thickness and the vertical rise in an attic or second story. Firestops are required at each floor level beyond the first floor ceiling support/wall thimble cover or cathedral ceiling support box. If an offset is required to avoid obstructions, use a pair of 4 elbows. For proper support, use elbow straps with offsets. Use wall straps for long vertical runs. ttic Insulation Shield is required in attic. Measure the roof pitch. Select the proper flashing and storm collar. etermine the minimum height above the roof. For horizontal installations, check the appliance manufacturer s instructions for minimum rise and maximum horizontal run. snorkel termination may be used if height restrictions prevent adequate rise above the appliance. Select the appropriate Horizontal Termination ap (see appliance manufacturer installation instructions). To protect vinyl siding, select vinyl siding standoff. heck appliance manufacturer s instructions for wall thimble and firestop requirements. esign Recommenation The following design recommendations are intended as only a general guideline to assist in the design and selection of venting components for your installation. lways read and follow Simpson ura-vent Installation instructions enclosed with the cap or support box before installing your chimney system. Installation instructions can be viewed online at under atalogs and Instructions. Important: heck the manufacturer s rating plate and instruction manual to confirm that the Simpson ura-vent direct vent system is approved for use on the brand name appliance you have selected. The inner and outer pipe diameters should match the outlet size of the appliance. heck the appliance manufacturer s installation instructions to confirm which types of vent configurations are permitted (i.e. horizontal, vertical, chimney reline, etc.). lso, check for any venting restrictions such as maximum horizontal run, minimum and maximum vertical rise, maximum offset, etc. e fire safe! Maintain at least the minimum clearances (air-space) between the vent pipe and nearby combustibles, as specified in the appliance manufacturer s installation instructions. Use proper support and bracing. Follow local building codes and have your venting system inspected. Vent Termination hart H X 12 Minimum Height Roof Pitch Feet Meters Flat to 7/ Over 7/12 to 8/ Over 8/12 to 9/ Over 9/12 to 10/ Over 10/12 to 11/ Over 11/12 to 12/ Over 12/12 to 14/ Simpson ura-vent 132
5 irectvent Pro irect Vent Horizontal Termination Kit Kit includes: 90 black Elbow, eiling Support/Wall Thimble over, 24 black Pipe, black Pipe Extension. Termination cap not included. For 4 x 6 8 direct vent. hoose termination cap to complete installation. STOK # 46V-KH Horizontal Termination Kit Kit includes: 90 black Elbow, Wall Thimble, eiling Support/Wall Thimble over, 24 black Pipe, black Pipe Extension. Termination cap not included. For 4 x 6 8 direct vent. hoose termination cap to complete installation. STOK # 46V-KH himney Liner Termination Kit / Kit includes: Termination onnector and Flashing. irectvent Pro 4 x 6 8 Termination aps, 3 Flex, and o-linear Flex onnectors are sold separately. irectvent Pro chimney liner termination kit must be tested and listed for each appliance. Refer to stove manufacturer s installation instructions. STOK # 46V-GK 133 Simpson ura-vent
6 irect Vent irectvent Pro Masonry himney onversion Kit 8¼ Kit 46V-KM includes: ap dapter, 18 x 18 Flashing, Round eiling Support/Wall Thimble over, Retro onnector. For 4 x 6 8 direct vent. Termination ap and 4 flex are sold separately. Kit 46V-KT includes: ap dapter and a 18 x 18 Flashing ⅝ Use with 4 x 6 8 direct vent gas stoves. Use existing masonry chimney. Route the exhaust gases and intake air through the side of the masonry chimney. 6⅞ 8⅝ STOK # 46V-KM 46V-KT 2⅛ 3⅜ 6⅝ 8⅝ himney onversion Kit Kits 46V-K, 46V-K, and 46V-K include: ap dapter and a Retro onnector. irectvent Pro 4 x 6 8 Termination ap and 4 flex are sold separately. Use with 4 x 6 8 direct vent gas stoves. Use existing through-theceiling, wood-stove metal chimney. Route the exhaust gases and intake air through the existing wood-stove metal chimney. 3⅜ 8⅝ 6⅝ STOK # 46V-K V-K V-K ONVERSION KIT K FITS: ONVERSION KIT K FITS: ONVERSION KIT K FITS: SIMPSON UR-VENT 6 URTEH SIMPSON UR-VENT 6-8 URPLUS SIMPSON UR-VENT 6 SEURITY HIMNEY 8 SEURITY HIMNEY 7 & 8 URPLUS 6 METLESTOS 7 & 8 METLESTOS 8 MERIN METLS 6 JKES-EVNS 7 & 8 JKES-EVNS 8 IR-JET 6 HRT & OOLEY 7 & 8 HRT & OOLEY 8 METL-F 6 PRO JET 7 & 8 PRO JET 6 & 7 MERIN METLS Simpson ura-vent 134
7 irectvent Pro irect Vent Pipe Length esigned for appliances tested and listed for direct vent. Features a fully unitized twist-lock construction in both 4 x 6 8 and x 8 vent sizes. Use of sealant is optional, unless specified by the appliance manufacturer. To calculate install length, subtract for each joint. No beads or hems. lack pipe lengths feature exterior laser-welded seams. SIZE GLVNIZE LK 4 x V-06 46V x V-09 46V x V-12 46V x V-18 46V x V-24 46V x V-36 46V x V-48 46V x V-60 46V x 8 8V-06 8V-06 6 x 8 8V-09 8V-09 9 x 8 8V-12 8V x 8 8V-18 8V x 8 8V-24 8V x 8 8V-36 8V x 8 8V-48 8V x 8 8V-60 8V Pipe Extension Use to add length to a straight length of irectvent Pro. 8½ pipe adds 3-7 of length, 16 pipe adds 3-14 ½ of length, when used with rigid sections of pipe. irect vent lengths feature a fully unitized, twist-lock construction. Use of sealant is optional, unless specified by the appliance manufacturer. vailable in black or galvalume exterior (both feature laser-welded outer wall seams). oes not fit irectvent GS pipe. SIZE GLVNIZE LK EXTENSION 4 x V-08 46V x V-16 46V ½ x 8 8V-08 8V x 8 8V-16 8V ½ 4 Elbow Use to offset obstructions as needed. Fully unitized, twist-lock construction. Elbows swivel, allowing the lock to remain fully engaged while aligning to the desired direction. The angle will remain fixed at 4. SIZE GLVNIZE LK 4 x V-E4 46V-E x 8 8V-E4 8V-E Simpson ura-vent
8 irect Vent irectvent Pro 90 Elbow Use to offset obstructions as needed. Fully unitized, twist-lock construction. Elbows swivel, allowing the lock to remain fully engaged while aligning to the desired direction. The angle will remain fixed at 90. SIZE GLVNIZE LK 4 x V-E90 46V-E x 8 8V-E90 8V-E Elbow Strap Use for supporting vent pipe between offsets. SIZE STOK # 4 x V-ES 6 8 x 8 8V-ES 8 17 eiling Support/ Wall Thimble over Use as a decorative cover for horizontal (through-wall) installations or for flat ceiling installations. Fits over the Wall Thimble face plate. Sealed with insulation to keep out air leakage. Painted black. SIZE STOK # 4 x V x 8 8V ⅛ athedral eiling Support ox Use to pass through ceiling and support pipe. May be used on vaulted or flat ceilings. Painted black. Trim and clamp included. 14 SIZE STOK # 4 x V-S x 8 8V-S Simpson ura-vent 136
9 irectvent Pro irect Vent Wall Thimble Provides a complete wall-pass-through and firestop. Use with Square Horizontal ap only. May be required in anada. Refer to the appliance manufacturer s installation instructions for requirements. 4 4 SIZE STOK # 4 x V-WT x 8 8V-WT NEW Wall Thimble - Reduced 4 4 Provides a complete wall-pass-through and firestop. Use with Round Horizontal ap and Sconce ap only. May be required in anada. Refer to the appliance manufacturer s installation instructions for requirements. SIZE STOK # 4 x V-WTS x 8 8V-WTS Wall Firestop For horizontal (through-wall) installations. Refer to the appliance manufacturer s installation instructions for requirements. SIZE STOK # 4 x V-WFS x 8 8V-WFS Vinyl Siding Standoff 1⅞ Use as a heat shield on structures with vinyl siding, or other temperature sensitive materials, to prevent warping and or melting of the material. Use only on horizontal terminations and on any irregular surfaced siding (ie: ship lag siding, shake shingle siding) so cap is not imbedded in the siding. Sized for Square Horizontal ap. SIZE STOK # 4 x V-VSS x 8 8V-VSS Simpson ura-vent
10 irect Vent irectvent Pro NEW Vinyl Siding Standoff Kit Use as a heat shield on structures with vinyl siding, or other temperature sensitive materials, to prevent warping and or melting of the material. Use only on horizontal terminations and on any irregular surfaced siding (ie: ship lag siding, shake shingle siding) so cap is not imbedded in the siding. New 4-piece design; sized for Square Horizontal ap only. Stainless steel (SS) kit for copper Square Horizontal ap. SIZE STOK # 4 x V-VSK x V-VSK-SS x 8 8V-VSK x 8 8V-VSK-SS NEW Vinyl Siding Standoff Kit - Reduced Use as a heat shield on structures with vinyl siding, or other temperature sensitive materials, to prevent warping and or melting of the material. Use only on horizontal terminations and on any irregular surfaced siding (ie: ship lag siding, shake shingle siding) so cap is not imbedded in the siding. New 4-piece design; sized for Sconce ap and Round Horizontal ap only. Stainless steel (SS) kit for copper Sconce ap. SIZE STOK # 4 x V-VSKS x V-VSKS-SS eiling Firestop Required for multi-story vertical installations at the second floor and any subsequent floors. SIZE STOK # 4 x V-FS x 8 8V-FS ttic Insulation Shield Required for installations that pass through an attic to prevent insulation and debris from accumulating near the vent. Provides 1 clearance to combustibles. Ø6¾ & Ø8 Ø6¾ djusts SIZE STOK # 4 x V-IS x 8 8V-IS 7 3 / / Simpson ura-vent 138
11 irectvent Pro irect Vent Wall Strap Use to support vent pipe. Provides 1 clearance. Recommend installing Wall Straps at 4-foot intervals on vertical runs. 1 SIZE STOK # 4 x V-WS 6 8 x 8 8V-WS 8 Restrictor isk ¼ 4 9/16 Use only in accordance with specific appliance manufacturer s installation instructions to restrict incoming combustion air. SIZE STOK # 4 x V-R x 8 8V-R 7 6 djustable Roof Flashing E 4 6 F E Use to weather proof the penetration of vent pipe through the roof. Storm ollar required. Select roof flashing based on pitch of roof. For pitches of 0/12-6/12. Made of galvalume. SIZE STOK # E F G 4 x V-F x 8 8V-F Steep Roof Flashing E 4 6 F E Use to weather proof the penetration of vent pipe through the roof. Storm ollar required. For roof pitches of Made of galvalume. SIZE STOK # E F 4 x V-F x 8 8V-F Flat Roof Flashing Use to weather proof the penetration of vent pipe through the roof. Storm ollar required. Use on flat roofs, chase enclosures, or masonry chimney. Made of galvalume. SIZE STOK # 4 x V-FF x 8 8V-FF Simpson ura-vent
12 irect Vent irectvent Pro S Flashings Use with metal or tile roofs. vailable in sizes 4 x 6 8 and x 8, in 0/12-6/12 (shown) and 7/12-12/12 styles. Made of dead soft aluminum. Refer to roof flashings tables (previous page) for dimensions. SIZE STYLE STOK # 4 x 6 8 0/12-6/12 46V-F6S 4 x 6 8 7/12-12/12 46V-F12S x 8 0/12-6/12 8V-F6S x 8 7/12-12/12 8V-F12S ounter Flashing 2 ¼ 2 3 Prevents water intrusion into stucco-sided homes. llows the installer to apply siding material (ie: stucco, brick, etc) over the flanges up to the sides of the flashing for a water-proof seal. 4-piece design; sized for Square Horizontal ap only. SIZE STOK # 4 x V-F x 8 8V-F NEW ounter Flashing - Reduced 2 ¼ 2 3 Prevents water intrusion into stucco-sided homes. llows the installer to apply siding material (ie: stucco, brick, etc) over the flanges up to the sides of the flashing for a water-proof seal. 4-piece design; sized for 4 x 6 8 Sconce ap and Round Horizontal ap only. SIZE STOK # 4 x V-FS Storm ollar Use to maintain a weather tight resistant seal between the pipe and the flashing. SIZE STOK # 4 x V-S x 8 8V-S x 6 8 x Simpson ura-vent 140
13 irectvent Pro irect Vent Round Horizontal Termination ap Use for through-the-wall terminations. heck installation instructions for restrictions on horizontal cap terminations, such as minimum distance from windows and doors. vailable in aluminum only. heck with appliance manufacturer for approval. SIZE STOK # 4 x V-HRS 11 ¾ x 8 8V-HRS 11 ¾ Sconce Termination ap Use for horizontal through-the-wall terminations. heck installation instructions for restrictions on horizontal cap terminations, such as minimum distance from windows and doors. vailable in aluminum, stainless steel (S), and copper (). heck with appliance manufacturer for approval. Patented. SIZE STOK # 4 x V-HS 11" " x V-HS-S 11" " x V-HS " x 8 8V-HS " x 8 8V-HS-S " x 8 8V-HS " Square Horizontal Termination ap Use for standard and high-wind through-the-wall terminations. heck installation instructions for restrictions on horizontal cap terminations, such as minimum distance from windows and doors. vailable in aluminum, stainless steel (S), and copper (). SIZE STOK # 4 x V-H x V-H-S x V-H x 8 8V-H x 8 8V-H-S x 8 8V-H Simpson ura-vent
14 irect Vent irectvent Pro Snorkel Termination ap Use for horizontal through-the-wall terminations when a vertical rise is desired in the system to meet appliance manufacturer recommended minimum heights. o not enclose in the wall or install below grade. Patented. SIZE STOK # 4 x V-SNK x V-SNK x 8 8V-SNK x 8 8V-SNK Horizontal Windguard ½ Use with through-the-wall termination cap where high winds are present. lso use as a safety heat shield to prevent children or others from coming into contact with the vent termination cap. SIZE STOK # 4 x V-WG 12 High-Wind Termination ap Use where high winds are present. For vertical terminations only. vailable in aluminum. SIZE STOK # 4 x V-VH x 8 8V-VH Low-Profile Termination ap Use for vertical terminations only. heck the appliance manufacturer s instructions to determine which caps are approved for use with their appliance. vailable in aluminum and stainless steel (S). SIZE STOK # 4 x V-V x V-V-S x 8 8V-V x 8 8V-V-S Simpson ura-vent 142
15 irectvent Pro irect Vent Extended Vertical Termination ap Use in extremely cold climates. Similar to the Low Profile Termination ap but taller in overall height to separate the air intake vents from the exhaust area. Refer to the appliance manufacturer s installation instructions for requirements. vailable in aluminum. SIZE STOK # 4 x V-VE x 8 8V-VE luminum Flex Length Use 3 flex with the co-linear system and 4 flex with onversion Kits. See uraflex L section for more information. Flexible.010 thick 2-ply aluminum. Pricing for luminum Flex Length are listed under uraflex L. SIZE LENGTH STOK # Flex oupling Use to join flex liner sections together. Pricing for luminum Flex Length are listed under uraflex L. 3 SIZE STOK # o-xial To o-linear ppliance onnector Use o-linear dapter for stoves with 4 X 6 8 co-axial outlets. Refer to appliance manufacturer s installation instructions for approval. Uses 3 aluminum flex for both intake and exhaust. SIZE ONNETOR STOK # 4 x 6 8 STNR 46V-GL x 6 8 TRVIS INUSTRIES 46V-TL x 6 8 VERMONT STINGS 46V-VL Simpson ura-vent
16 irect Vent irectvent Pro ppliance dapter ttaches to appliance outlet allowing pipe to easily connect or disconnect. For Vermont astings appliances. SIZE STOK # 4 x V-P o-linear Flex onnector Use as a flex connector with inserts with 3 co-linear intake and exhaust ports. 4¼ 3 9/16 3 SIZE STOK # 4 x V-F 3 Offset hart OFFSET RISE Elbow egrees SIZE 4 x 6 8 x 8 himney Section Offset Inches Rise Inches Offset Inches Rise Inches Note: Refer to Simpson ura-vent s Hearth Pricebook for conversion from irectvent GS (stock#) to irectvent Pro (order #) sku s Simpson ura-vent 144
Vent Termination Chart. horizontal Termination Kit A. horizontal Termination Kit C. Chimney Liner Termination Kit. DirectVent Pro Direct Vent
irectvent Pro irect Vent Vent Termination hart H X 12 Minimum height Roof Pitch Feet Meters Flat to 7/12 1 0.30 Over 7/12 to 8/12 1.5 0.46 Over 8/12 to 9/12 2 0.61 Over 9/12 to 10/12 2.5 0.76 Over 10/12
More informationDuraPlus. All-fuel, triple-wall chimney system. UL 103 HT.
DuraPlus ll-fuel, triple-wall chimney system. UL 103 HT. Specifications pplications DuraPlus himney is a triple-wall, all-fuel chimney for use with wood stoves, fireplaces, furnaces, boilers, stoves, ranges,
More informationSimpson Dura-Vent Engineered Excellence
DuraLiner Simpson Dura-Vent Engineered Excellence pplications Materials and onstruction DuraLiner DuraLiner ensures safe and efficient venting of heating appliances, while protecting the masonry chimney
More informationGas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth
28-15/16 (735mm) Model P36D-NG10 P36D-LP10 Fuel Type Natural Gas Propane Gas Fireplaces Minimum Supply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.25 kpa) 3.8 W.C. (0.95 kpa) 1.1
More informationInstallation Instructions. Venting System For Direct Vent Gas Stoves and Fireplaces. DirectVent Pro
Installation Instructions Venting System For Direct Vent Gas Stoves and Fireplaces DirectVent Pro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE
More informationDuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.
DuraFlex Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635. Specifications DuraFlex SW Applications DuraFlex SW smooth wall flexible relining for masonry chimney. Use with gas,
More informationGas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth
P33 Zero Clearance Direct Vent Gas Fireplace P33 WITH THE FLUSH OR BAY FRONT Model P33-NG4 P33-LP4 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) Manifold Pressure
More informationFIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS
FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS ENCLOSURE MODEL 90566400 FOR INSERT MODEL 5660NA And ENCLOSURE MODEL 90566000 FOR INSERT MODEL 5660 STANDARD KEEP THESE INSTRUCTIONS FOR FUTURE USE
More informationZ-Vent Model SVE Series III
Special Stainless Steel Venting System for Gas Burning Appliances Category I, II, III, & IV Tested and Listed By Underwriters Laboratories Inc. UL 1738 & BH636 Note the following before installation of
More informationDIRECT-TEMP SELKIRK DIRECT VENT SYSTEM
C I NTERTEK War nock CM Her sey US U L LISTED CAUTION: WEAR GLOES WHILE HANDLING SHEET METAL PARTS TO AOID PERSONAL INJURY. SHARP EDGES OR PROJECTIONS CAN CUT YOU. Selkirk DIRECT-TEMP Direct ent system
More informationDuraFlex AL. Installation Instructions
Installation Instructions Flexible aluminum relining system for relining masonry chimneys for natural gas or liquid propane category I, draft hood equipped appliances, and appliances tested and listed
More informationInstallation Instructions. Air-Cooled Chimney for Isokern Fireplaces
Installation Instructions Air-Cooled Chimney for Isokern Fireplaces A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST
More informationInstallation Instructions. High-Temperature, Factory Insulated Double-Wall Masonry Relining system 5" Round 6", 8" Round and Oval.
Installation Instructions High-Temperature, Factory Insulated Double-Wall Masonry Relining system 5" Round 6", 8" Round and Oval DuraLiner A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED
More informationInstallation Instructions. Converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent System. DirectVent Pro
Installation Instructions Converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent System DirectVent Pro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR
More informationINSTALLATION INSTRUCTIONS
CHIMNEY CONNECTOR WALL THIMBLE MODEL IWT INSTALLATION INSTRUCTIONS Warnock Hersey C US LISTED ULC-S641/UL103 IT IS OF THE UTMOST IMPORTANCE THAT THIS WALL THIMBLE BE INSTALLED ONLY Y IN ACCORD CCORDANCE
More informationConcentric Vent/Air System Supplement
Concentric Vent/Air System Supplement This document is intended to be used by a qualified heating contractor or service technician. Read all instructions within this document and within the CHAL- LENGER
More informationHIGH EFFICIENCY POSITIVE PRESSURE VENTING SYSTEMS FOR CONDENSING APPLIANCES, CATEGORIES II, III AND IV Single & Double Wall Construction
HIGH EFFICIENCY POSITIVE PRESSURE VENTING SYSTEMS FOR CONDENSING APPLIANCES, CATEGORIES II, III AND IV Single & Double Wall Construction Models HEP HEPL HEPL2 28 KJ This symbol shows that CHEMINÉE LINING.E
More informationMETALLIC CHIMNEY LINER SYSTEMS
SINGLE WLL CONSTRUCTION RIGID CHIMNEY LINER METLLIC CHIMNEY LINER SYSTEMS TECHNICL DT ND PRTS SELECTION Models CBI and CBH Commerical/Industrial Stainless Steel Single Wall Construction CONTENTS SECTION...
More informationRediflow Concrete Gas Flue System
Rediflow Concrete Gas Flue System Rediflow Concrete Gas Flue System Rediflow the complete gas flue block system Red Bank s range of Rediflow pre-cast concrete gas flue block system manufactured to BS EN
More informationSUBMITTAL RECORD. Material Selection FLUE (INNER WALL) CASING (OUTER WALL) GALVALUME
SUBMITTAL RECORD UL 1978 - Grease Duct Professional Series Kitchen Ventilation DCL Single Wall DAS1 1-inch Air Insulated DIS1 1-inch Insulated (AES WOOL) DIS2 2-inch Insulated (AES WOOL) DIS4 4-inch Insulated
More informationSI T T FST
SI 440-600-700-700T-780-780T-900-1100 Freestanding TAPER TOP Open Fire - Wood Burner Installation Instructions Note: FLUE SYSTEMS Casing. Flue System may require to be Doubled Lined to Comply. Ref ASNZS:2918:2001
More informationROOF MOUNT KIT OWNERS MANUAL
ROOF MOUNT KIT OWNERS MANUAL Made in the USA by: Primus Wind Power, Inc. 938 Quail St. Lakewood, CO 80215 Phone: (303) 242-5820 www.primuswindpower.com AIR is a trademark of Primus Wind Power, Inc. ROOF
More informationNouveau BBQ Single Flue
Nouveau BBQ 900-1100-1250-1500 Single Flue Outdoor BBQ Cooking Fire Wood Burner Installation Instructions FLUE SYSTEMS Casing. Flue system may require to be doubled lined to comply. Ref ASNZS:2918:2001
More informationMODEL IPIC SERIES 4G GREASE DUCT
INSTALLATION AND MAINTENANCE INSTRUCTIONS WALMART APPLICATION 637N MODEL IPIC SERIES 4G GREASE DUCT 7N71 IT IS OF THE UTMOST IMPORTANCE THAT THIS DUCT BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS.
More informationDunbrik A1 Concrete Flue Liners
Dunbrik A1 Concrete Flue Liners System Guide Firebelly stove FB2 woodburner in pewter domestic flue & chimney systems Certificate No.FM24104 Benefits of a Chimney A chimney adds appeal to a house A real
More informationTaking value to the highest level.
Venting Solutions Taking value to the highest level. Example: 2D Drawings Schebler Chimney Systems is a premier source of custom, modular prefabricated stainless steel chimneys, heavy wall engineered stacks,
More informationPIPE
The highest quality stainless steel liners at the best prices in the industry. The Lifetime Mission At Lifetime Chimney Supply, we make the highest quality stainless steel chimney liners, sell them at
More informationAir flue duct for use with ecotec boilers
For the installer Flue installation instructions Air flue duct for use with ecotec boilers Concentric System Ø 80/5 (Galvanized steel air duct/plastic flue duct) GB Contents Notes on the documentation
More informationSECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:
SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.
More informationQuality Inspection 8618 London Heights San Antonio, TX Phone: (210)
Quality Inspection 8618 London Heights San Antonio, TX 78254 Phone: (210) 240-0476 PRE DRYWALL INSPECTION REPORT Prepared For: DELETED (Name of Client) Concerning: DELETED, San Antonio, TX 78258 (Address
More informationTC54. for architects & designers. Dimensions Clearances Venting
for architects & designers TC54 Series D Dimensions Clearances enting IMPORTANT This booklet is intended as a basic specification guide for architects, designers and builders. Please refer to the Instruction
More informationInstallation Instructions
InnoFlue Single Wall, Flex, Concentric Vent System The installation instructions should be kept with the appliance for maintenance. Examine all components for possible shipping damage prior to installation.
More informationInstallation instructions
Installation instructions Holetherm Double-walled flue gas discharge system (DW) 2016 All information in this release is subject to misprints. No liability is accepted for the consequences of misprints.
More informationInstallation Manual Installation and Fireplace Setup
Installation Manual Installation and Fireplace Setup INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. NOTICE: DO NOT discard this
More informationInstallation Manual Installation and Fireplace Setup
Installation Manual Installation and Fireplace Setup INSTALLER: Leave this manual with party responsible for installation and operation. OWNER: Retain this manual for future reference. Contact your dealer
More informationRadon Vent Pipe System. Labeling Performance Indicators
Section 6 Radon Vent Pipe Labeling Performance Indicators Radon Vent Pipe System Connected after sub-grade system installed Pipe cannot be trapped Provide space in chases Support at each floor level Discharge
More informationThe Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage
The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco
More informationHow to choose the best furnace?
How to choose the best furnace? We assume that the house has an average insulation, quality windows and doors and 8 foot ceilings, with a location in an area where winter temperatures are comparable to
More informationInstallation Manual Installation and Fireplace Setup
Installation Manual Installation and Fireplace Setup INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. This fireplace uses SL1100
More informationMasonry Firebox. Models MM33, MM39, MM44, MM49 and MM63
Instructions Masonry Firebox Models MM33, MM39, MM44, MM49 and MM63 IF FIREPLACE IS TO BE INSTALLED DIRECTLY ON ANY COMBUSTIBLE MATERIAL, A METAL BASE IS REQUIRED. SAVE THIS BOOK This book is valuable.
More informationKAZAN: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2 2. PRE-INSTALLATION 3 3. INSTALLATION 6 4. OPERATION TESTING 11. Keep for future use
KAZAN: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2 2. PRE-INSTALLATION 3 3. INSTALLATION 6 4. OPERATION 10 5. TESTING 11 Keep for future use 1. TECHNICAL DATA WEIGHT AND DIMENSIONS: Dimensions Firebox W642
More informationRoof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208
Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details D-3 Roof Details M-1 Mechanical - Roof Plan M-2 Mechanical - Details Roof Key Plan
More informationThis wood burning fireplace complies with UL127 standard as a FACTORY BUILT APPLIANCE.
INSTALLATION AND OPERATION INSTRUCTIONS GRAND MERIDIAN MASONRY FIREBOX MODELS MM33, MM39, MM44, MM49, MM63 Report No. P125160 01 P/N 125160-01 Rev. B 02/14/14 ICC Evaluation Services Report No. 2401 IF
More informationViking Enviroclad Waterproofing Membrane. EC01 Enviroclad Drip Edge Specify from the above three options
*lum ngle 50x50x1.6mm min. with 20mm lum fixing bar to mechanically secure membrane Enviroclad Waterproofing Membrane Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet
More informationGCI60 Hampton Cast Iron Pellet Insert
CI60 Hampton Cast Iron Pellet Insert 26 7 8 24 ¾ 16 3 8 43 3 16 33 9 16 41 7 8 11 ¾ 22 15 16 12 ¾ FI60 Wood Pellet Insert INSTALLED AS A FIREPLACE INSERT STOVE MODEL (FPI) / A INSTALLE COMME UN MODELE
More information200 Series In-Slab Pool Fittings
230 Series nti-vortex Plate 2-2 231 Series Sump 2-3 234 Series Sump 2-4 236 Series Sump 2-5 253 Series Overflow 2-6 255 Series Overflow/Drain 2-7 261 Series Vacuum Fitting 2-8 263 Series Eyeball Fitting
More informationSECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS
SECTION 270528 PATHWAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Communications equipment coordination and installation. 2. Sleeves for pathways and cables. 3. Raceway
More informationMETALLIC CHIMNEY LINER SYSTEM Single Wall Construction Rigid Chimney Liner. Installation Instructions. Models
METALLIC CHIMNEY LINER SYSTEM Single Wall Construction Rigid Chimney Liner Installation Instructions Models IPP Cat. I: Part 1 HEP Cat I, II, III, IV: Part 2 3STS This symbol shows that Cheminée Lining.E
More informationThe better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs November 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements....................................
More informationPREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and
PREP + INSULATION HOME ENERGY UPGRADES What every contractor needs to know. Copyright 2012 Advanced Energy. All Rights Reserved 103 HOME ENERGY UPGRADES Prep + Insulation Contents Air sealing is a challenging
More informationInstallation Manual Installation and Fireplace Setup
Installation Manual Installation and Fireplace Setup INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. NOTICE: DO NOT discard this
More informationDIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: EARTHCORE INDUSTRIES, LLC
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2316 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 10 00
More informationAdministrative Changes
Revised 11/29/06 Knox County Residential Building Codes Significant Changes From The 1995 CABO One And Two Family Dwelling Code To The 2006 International Residential Code All one and two family dwellings
More informationMODEL N, VSI, IVSI & ZC SINGLE WALL, DOUBLE WALL AIR & CERAMIC FIBER INSULATED POSITIVE PRESSURE PIPING SYSTEMS
INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE MODEL N, VSI, IVSI & ZC SINGLE WALL, DOUBLE WALL AIR & CERAMIC FIBER INSULATED POSITIVE PRESSURE PIPING SYSTEMS BOILER STACK ENGINE EXHAUST GREASE DUCT VENTILATION
More informationKiva Fireplace GAS BURNING INSTALLATION MANUAL
18 24 30 Kiva Fireplace GAS BURNING INSTALLATION MANUAL Frame Models: Orno Santa Fe Navajo Zuni Keep these instructions for future use. C This fireplace is to be installed ONLY by a construction industry
More informationIndex Rigid Chimney Liner, Flex & Insulation. Section 300. Wood
Index 3 4 5 6 7 8 9 Section 3 Wood Page Number Vendor Product Publish Date 3 Z-Flex Heavy Flex Liner & Fittings 5/7 3-3 Z-Flex Flex Stainless Steel Flex Kits 5/7 33-34 ICC Excel Liner 6/6 35-3 Reliance
More informationSEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets
SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets Seismic Frame Two-Post Rack Page 11-3 Seismic Protection Products - Racks Page 11-6 Seismic Protection Products - Runway Page 11-8 Seismic
More informationWood Burning Fireplace
Wood Burning Fireplace OWNER S OPERATION AND INSTALLATION MANUAL ICC-ES #ESR-2542 (V)GM36, (V)GM42 AND (V)GM50 Series and WCM-36G, WCM-42G and WCM-50G Wood Burning Masonry Fireplaces with Insulation SAVE
More informationQuestar ThermWise Duct Technical Specifications
Questar ThermWise Duct Technical Specifications 1. Introduction and Scope: This document sets forth the specifications for duct sealing and duct insulation in accordance to Questar ThermWise Weatherization
More informationSECTION TURBINE VENTILATORS
SECTION 07 72 00 TURBINE VENTILATORS **This is a CSI Three-Part Specification using CSI MasterFormat 2004-2010 Section Numbers and Titles. This specification must be edited to suit your particular project.
More informationModern Rumford. MR 48 fireplaces
Modern Rumford MR 48 fireplaces Construction Guidelines For MR-48-1 Kit System Cellar Building, Suite 300 1124 NW Couch Street Portland, OR 97209 Ph. 503-227-0547 Fax 503-227-0548 info@mobergfireplaces.com
More informationInstallation instruction
Installation instruction Ci51 www.contura.eu 114 CERTIFICATE Declaration of performance according to Regulation (EU) 305/2011 No. Ci51-CPR-150821-SE-2 PRODUCT Product type Type designation Manufacturing
More informationwhere high efficiency is the standard
Access Doors 2016 where high efficiency is the standard Experience Milcor offers years of experience in the manufacture of a broad range of products and services for residential, commercial, institutional
More informationINSTALLATION AND MAINTENANCE INSTRUCTIONS FOR
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR FLEXIBLE STAINLESS STEEL RELINING PIPE Lifetime Warranty UL/ULC Listed Sizes: 3" 8" diameters Manufactured Exclusively for: Copperfield Chimney Supply, 304
More informationALL STEEL SHED FRAMES
ALL STEEL SHED FRAMES ABOVE DISPLAY IS AN 8X8 PORTABLE STEEL SHED FRAME WITH FLOOR STRUTS ON 2 FT CENTER SPACING USING QUICK BUILD CONNECTORS - 3 DOOR IS PLACED IN SHORT WALL (configuration of steel may
More informationthe heart of a warm home
the heart of a warm home INSTALLATION HANDBOOK FOR THE FIRENZO INSERT RU FIRES RURAL WOODFIRE THIS FIRE CAN ONLY BE INSTALLED ON PROPERTIES OVER 2 HECTARES The Appliance and Flue System must be installed
More informationOriginal Scandinavian rainwater system
Original Scandinavian rainwater system Siba Siba Square Contents Siba rainwater systems 3 Measuring 15-16 Siba 4-9 Gutter brackets 18-19 Siba Square 10-11 Gutters 20-23 Materials 12 Angles 24 Technical
More informationFor large capacity, easy installation and
Trenchduct Trenchduct Feeder System for Wallduct, Underfloor Duct, and Cellular Raceways For large capacity, easy installation and future flexibility, trenchduct is the feeder system of choice for infloor
More informationMaterials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.
Pipe clamps offered in this section are designed for support and attachment of pipe to structural members. wide range of pipe clamps are available for various applications. Materials arbon Steel is used
More information170MM 360MM Specifications
170MM 360MM 2016 Specifications EMISSION & EFFICIENCY The National Environmental Standards (NES) require a minimum 65% efficiency and maximum 1.5 grams emission requirement on all wood fires installed
More informationMaterials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.
Pipe clamps offered in this section are designed for support and attachment of pipe to structural members. wide range of pipe clamps are available for various applications. Materials arbon Steel is used
More informationA. Access doors and frames are part of an access door and frame allowance.
SECTION 08 31 13 ACCESS DOORS AND FRAMES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationTHE WORLD LOOKS UP TO COMPOSITE ELEVATED TANK
THE WORLD LOOKS UP TO COMPOSITE ELEVATED TANK or our breadth of capability. Of all the storage tank manufacturers doing business today, no other offers Caldwell s range of capability. We are the only manufacturer
More informationINDUSTRIAL GUARDRAIL SYSTEMS
INDUSTRIAL GUARDRAIL SYSTEMS STRONGEST GUARDRAIL ON THE MARKET MANUFACTURED IN THE U.S.A. BEST PRICES MOST VARIETIES HEAVY DUTY ONE-LINE OR TWO-LINE Posts: 4 Sched 80 pipe Rail: 6 Sched 40 pipe Sleeved
More informationPREFA Aluminiumprodukte GmbH Page 1 of 21
Tender Specifications 120901 PREFA Shingles_2012 ---------------------------------------------------------------------------------- 01. Text GENERAL PRELIMINARY REMARKS Roof ----------------------------------------------------------------------------------
More informationRECONSTRUCTION AND REPLACEMENT OF EARTHQUAKE DAMAGED MASONRY CHIMNEYS
INFORMATION BULLETIN / PUBLIC BUILDING CODE REFERENCE NO.: LABC 2113 and LARC R1001 DOCUMENT NO.: P/BC 2014-070 Previously Issued As: P/BC 2008-070 Effective: 01-01-2014 Revised: 01-16-2014 RECONSTRUCTION
More informationWHERE HIGH EFFICIENCY IS THE STANDARD
ACCESS DOORS 2017 WHERE HIGH EFFICIENCY IS THE STANDARD EXPERIENCE Milcor offers years of experience in the manufacture of a broad range of products and services for residential, commercial, institutional
More informationALLMET CONTINENTAL INSTALLATION GUIDE
ALLMET CONTINENTAL INSTALLATION GUIDE www.allmet.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Allmet Continental
More informationSflue. Twin Wall Flue TOVE TOVE. Economical twin wall, insulated stainless steel chimney system for wood burning/multi fuel stoves
TOVE Sflue TOVE Sflue Twin Wall Flue Economical twin wall, insulated stainless steel chimney system for wood burning/multi fuel stoves 100% Manufactured in the UK Introduction Sflue chimney system has
More informationCasement Windows Montecito New Construction Window
Casement Windows Montecito New Construction Window Full casement Double-bottom casement FULL DOUBLE/SINGLE DOUBLE CASEMENT - Min 1 6 1 0 Max 3 0 5 0 or 2 6 6 0 CASEMENT - Min 3 0 1 6 Max 6 0 5 0 or 5 0
More informationFLUE KIT INSTALLATION MANUAL
FLUE KIT INSTALLATION MANUAL 7 76 9 55 ROOM SEALED TELESCOPIC FLUE 7 76 9 086 PLUME MANAGEMENT SYSTEM GREENSTAR 60/00 HORIZONTAL FLUE FOR USE WITH WORCESTER GREENSTAR GAS-FIRED APPLIANCES: Greenstar FS
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.
0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1143 Reissued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00 THERMAL
More informationEcoteck Amalfi Freestanding. Wood Pellet Burning Heater
coteck Amalfi reestanding Wood Pellet urning Heater c o t e c k A m a l fi r e e s t a n d i n g Wood Pellet urning Heater Installation Specifications Safety testing of the coteck Amalfi reestanding Wood
More information5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More information7520 Casement Windows
Full casement Single casement Double-bottom casement Double casement FULL DOUBLE CASEMENT - Min 1 9 1 6 Max 3 0 5 0 or 2 6 6 0 CASEMENT W/ PICTURE - Min 4 6 1 6 Max 12 0 6 0 with 30 vent set - Minimum
More informationCHECKLIST Inspecting a Garage
CHECKLIST Inspecting a Garage By Ben Gromicko This section deals with the details of the garage or carport inspection that may be performed. At the end of this section, you shall be able to: describe the
More informationSECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System
SECTION 13096 RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13096-1 RF WELDED SYSTEM PART 1 GENERAL 1.1 SECTION
More informationSECTION SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.
More informationSECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection
SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION
More informationSECTION HVAC DUCTS AND CASINGS
SECTION 23 31 00 HVAC DUCTS AND CASINGS PART 1 -GENERAL 1.1 SUMMARY A. Section includes metal ductwork, nonmetallic ductwork, casing and plenums, buried ductwork, kitchen hood ductwork, duct cleaning.
More informationNOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)
NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION MASTERFORMAT SECTION 04818 (Mortarless Concrete Brick Veneer) Spec_USA_En_18102005.doc 12/1/2005 Novabrik Page 2 Section 04818 NOVABRIK MORTARLESS
More informationSECTION METAL DUCTS
SECTION 15815 METAL DUCTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More informationKS SERIES - VERTICAL INSTALLATION
CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV
More informationVertigo Cladding Board
Installation guide Vertigo Cladding Board Geolam: a stunning alternative to wood cladding Vertigo is a composite wood cladding board requiring minimum maintenance. Durable and fade resistant, it will not
More informationComplete Cupola Units
Table of Contents Steeples...3-10 Steeple & Cupola Accessories...11 Cupola...12-14 Lighthouse...15 Domes...16 Finials...17 Steeple & Cupola Installation Guidelines...18-19 Baptistries...20-24 Baptistry
More informationAdvanced Ventilation for Residential applications FBC Res 2010.
Advanced Ventilation for Residential applications FBC Res 2010. Course Description Review of the Residential Ventilation requirements in the Florida Building Code, Residential 2010. I. Introduction Dean
More informationAwning Windows Montecito New Construction Window
Awning Windows Montecito New Construction Window Full awning Double-top awning Double awning Double-bottom awning FULL DOUBLE BOTTOM/TOP DOUBLE AWNING - Min 1 3 1 4 Max 4 6 3 0 AWNING - Min 3 0 1 6 Max
More informationDiffused Aeration Piping Equipment
1.0 General 1.1. The specifications in this section include all components of the Diffused Aeration System with the exception of the individual diffuser units. Refer to additional specification sections
More informationGARAGES/ONE-STORY City of Grand Rapids Building Safety Division
GARAGES/ONE-STORY City of Grand Rapids Building Safety Division 218-326-7601 www.cityofgrandrapidsmn.com This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building
More informationGeneral. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings
application instructions STRAND SUBSTRATE 38, 76 AND 190 SERIES PRIMED PANEL SIDING INCLUDING SILVERTECH & SMARTFINISH General At the time of manufacture, siding meets or exceeds the performance standards
More information