Issue date: 1st May Key changes since original publication (July 2005):

Size: px
Start display at page:

Download "Issue date: 1st May Key changes since original publication (July 2005):"

Transcription

1 Issue date: st May 008 Key changes since original publication (July 00): May 008 Pages 0 & tables a & b - spec A06A08 Sound Insulation changed from 0 to 9 Rw db rating. September 00 Pages 66 & 6 tables a & b - specs A066 & A069 changed from Medium to Heavy duty rating; spec A0608 Sound Insulation changed from to 8 Rw db rating. Pages 0 & tables a & b - additional detail SoundBloc spec included (A06A) and new drawing inserted. Specs and have now become and 6. Pages & tables a & b - spec A06 changed from Medium to Heavy duty rating. January 00 Page 8 Deflection head detail 8 - downward deflection text in heading deleted. October 006 Page 0 Spec changed from 8dB to db on the 0 mins fire resistance section. Page Spec changed from 8dB to db on the 0 mins fire resistance section. Page 8 Gyproc Sealant corrected on all drawings. August 006 Whole section Isowool branding changed to Isover. Page 6 Services installation image changed. Page 6 60 minute multiboard spec duty rating changed from Heavy to Severe. Page 80 Construction detail 6 changed to illustrate single layer boards. April 006 Pages 0,, 6, Various maximum partition heights changed. December 00 Page Maximum partition height of A0609 changed from 000mm to 600mm. Gyproc, Thistle, Gypframe, Glasroc and Arteco are all registered trade names of BPB United Kingdom imited. Isover is a registered trade name of Saint-Gobain. British Gypsum reserve the right to revise product specification without notice. The information given is correct to the best of our knowledge at the time of publication, but it is the users responsibility to ensure it remains current prior to use. Please refer to our Product Data Sheet which is available on request. For a comprehensive and up to date library of information visit our website at: Technical enquiries British Gypsum imited, Drywall Academy Technical Advice Centre, East eake, oughborough, eicestershire E 6JT Telephone: # (iterature), # (Specifiers), # (Merchants), # (Contractors) For quality and security reasons, calls may be recorded. Fax: bgtechnical.enquiries@bpb.com Training enquiries: Gypwall-classic-0.pdf British Gypsum THE WHITE BOOK 00

2 The definitive metal stud partition system John ewis, Southampton 60

3 Partitions for a wide range of applications partitions are cost-effective, multi-purpose partitions, which have provided the industry standard for many years. They are suitable for all types of buildings, including residential, healthcare and commercial, and are approved for use in hospitals by the Department of Health and the Welsh Office (refer to HTM 6, Partitions) db mins Sector Office / commercial Educational Residential Healthcare eisure Industrial Gypframe C Stud Gypframe AcouStud Key facts Range of stud options to match performance requirements Acoustic stud option for enhanced acoustic performance Satisfy BS strength and robustness requirements up to Severe Duty 0-0 minutes fire resistance to BS and EN standards Achieve high levels of sound insulation up to R w 6 db Accommodate services within stud cavity Can allow for deflection at the head Gypframe metal framework will not twist, warp or rot 6

4 System components Gypframe metal products 8 S 0 C Stud ength 00, 00mm 000, 00, 600mm 0 S 0 C Stud ength 00, 00mm 000, 00mm 600, 00mm 0 AS 0 AcouStud ength 00, 00mm 000, 600mm 600, 00mm 9 S 0 C Stud ength 600, 00mm 6 S 0 C Stud ength 00, 00mm 000, 00mm 00mm 6 AS 0 AcouStud ength 600, 00mm Floor & Ceiling Channels Standard, Deep Flange Floor & Ceiling Channel (DC) and Extra Deep Flange Floor & Ceiling Channel (EDC). All channels are available in 600mm only. 99 FC 0 Fixing Channel ength 00mm Gyproc and Glasroc board products (cont d) Gyproc SoundBloc Thickness., mm Width 00mm Gyproc Plank Thickness 9mm Width 600mm Glasroc MultiBoard Thickness 6, 0,.mm Width 00mm Moisture resistant boards are specified in intermittent wet use areas e.g. shower cubicles. Fixing and finishing products Gyproc Wafer Head Drywall Screws For metal-to-metal fixing up to 0.9mm thick. or Gyproc Wafer Head Jack-Point Screws For metal-to-metal fixing 0.8mm thick or greater and I studs greater than 0.mm thick. Gyproc Drywall Screws For fixing boards to stud framing up to 0.9mm thick. or Gyproc Jack-Point Screws For fixing boards to stud framing 0.8mm thick or greater and I studs greater than 0.mm thick. Gyproc Sealant Sealing air paths for optimum sound insulation. Gyproc jointing materials For seamless jointing. GFS Fixing Strap or GFT Fixing T GA Internal Fixing Angle ength 00mm ength 00mm ength 600mm Gyproc edge beads To protect and enhance board edges. Gyproc Control Joint To accommodate structural movement. GA6 Splayed Angle ength 00, 600mm Gyproc and Glasroc board products Gyproc FireStrip For fire-stopping deflection heads. Thistle Board Finish or Thistle Multi-Finish To provide a plaster skim finish. Gyproc WallBoard Thickness Width., mm 00mm Isover APR 00 mm and 0mm, for improved acoustic performance. Gyproc Fireine Thickness Width., mm 00mm Stone Mineral Wool For providing acoustic / thermal insulation. Always use genuine branded British Gypsum components to qualify for SpecSure lifetime warranty 6

5 T F E bgtechnical.enquiries@bpb.com Installation overview Gypframe Floor & Ceiling Channel is fixed at the head and base. Gypframe studs are fitted vertically to a friction-fit within the channel sections, and to abutments, to form the framework. This allows for adjustment during boarding. Studs are fitted so as to all face the same way. Additional framing is installed as required to support heavy fixtures. Boards are screw-fixed to framing members to form the lining. Horizontal board-end joints of face lining boards should be backed with Gypframe GFS Fixing Strap (double layer) or Gypframe GFT Fixing T (single layer). Openings Details for openings differ according to Duty requirements. See Design - Openings for further details. Services Electrical and other services are normally installed after one side is boarded. Horizontal runs are routed through cut-outs in the studs. Gypframe 99 FC 0 Fixing Channel can be installed between studs to support recessed switch boxes / socket outlets, or a high performance socket box detail used where higher acoustic performance is required. For full installation details, refer to the British Gypsum SITE BOOK or visit 6

6 Performance ( EN One layer of board each side of 8mm Gypframe C Studs at 600mm centres. Refer to - Basic principles of system design) Table a 8mm Gypframe C Studs - single and double layer board linings One layer of board each side of 8mm Gypframe C Studs at 600mm centres. mm Isover APR 00 in the cavity. Two layers of board each side of 8mm Gypframe C Studs at 600mm centres. Two layers of board each side of 8mm Gypframe C Studs at 600mm centres. mm Isover APR 00 in the cavity. type thickness thickness weight partition height R w rating reference mm mm kg/m mm db 0 minutes fire resistance EN WallBoard x Medium A0600 WallBoard x Medium A0600 SoundBloc x. 00 Medium A06 SoundBloc x Medium A06 WallBoard x Medium A060 WallBoard x Medium A060 SoundBloc x. 00 Medium A068 SoundBloc x Medium A068 WallBoard x Severe A0600 WallBoard x Severe A minutes fire resistance EN Fireine x Heavy A06066 MultiBoard x Severe G0600 Fireine x Heavy A06098 SoundBloc x Severe A06 WallBoard x 0 00 Severe A0600 SoundBloc x Severe A minutes fire resistance EN SoundBloc x Severe A06 Fireine x Severe A0606 SoundBloc x Severe A068 0 minutes fire resistance EN Fireine x Severe A0606 Fireine x Severe A066 Fireine x Severe A06099 The maximum heights quoted are limited by the fire state field of application or by limiting deflection of /0 at 00Pa, whichever is the more onerous. NBS work section K0 - Plasterboard drylinings / partitions / ceilings 6

7 T F E bgtechnical.enquiries@bpb.com BS One layer of board each side of 8mm Gypframe C Studs at 600mm centres. Table b 8mm Gypframe C Studs - single and double layer board linings One layer of board each side of 8mm Gypframe C Studs at 600mm centres. mm Isover APR 00 in the cavity. One layer of board each side of 8mm Gypframe C Studs at 600mm centres. 0mm Isover APR 00 in the cavity. Two layers of board each side of 8mm Gypframe C Studs at 600mm centres. Two layers of board each side of 8mm Gypframe C Studs at 600mm centres. mm Isover APR 00 in the cavity. type thickness thickness weight partition height R w rating reference mm mm kg/m mm db 0 minutes fire resistance BS MultiBoard x Heavy G06006 WallBoard x Medium A0600 WallBoard x Medium A0600 SoundBloc x. 00 Medium A06 SoundBloc x Medium A06 WallBoard x Medium A060 WallBoard x Medium A060 SoundBloc x. 00 Medium A068 SoundBloc x Medium A minutes fire resistance BS MultiBoard x Severe G0600 Fireine x Heavy A06066 Fireine x Heavy A06098 MultiBoard x Heavy G06008 WallBoard x Severe A0600 SoundBloc x Severe A06 WallBoard x Severe A060 SoundBloc x Severe A minutes fire resistance BS WallBoard x 0 00 Severe A0600 SoundBloc x Severe A06 WallBoard x Severe A0606 SoundBloc x 0 00 Severe A068 0 minutes fire resistance BS MultiBoard x Severe G060 Fireine x Severe A0606 Fireine x Severe A06099 Based on a limiting deflection of /0 at 00Pa. NBS work section K0 - Plasterboard drylinings / partitions / ceilings 6

8 Performance ( EN Refer to - Basic principles of system design) Table a 0mm Gypframe C Studs - single layer board linings One layer of board each side of 0mm Gypframe C Studs at 600mm centres. One layer of board each side of 0mm Gypframe C Studs at 600mm centres. mm Isover APR 00 in the cavity. One layer of board each side of 0mm Gypframe C Studs at 600mm centres. 0mm Isover APR 00 in the cavity. type thickness thickness weight partition height R w rating reference mm mm kg/m mm db 0 minutes fire resistance EN WallBoard x Medium A060 WallBoard x Medium A060 SoundBloc x Medium A066 The maximum heights quoted are limited by the fire state field of application or by limiting deflection of /0 at 00Pa, whichever is the more onerous. SoundBloc x Heavy A066 WallBoard x Medium A060 WallBoard x Medium A0606 SoundBloc x Medium A0696 SoundBloc x Heavy A069 WallBoard x Medium A068 WallBoard x Medium A069 SoundBloc x Medium A minutes fire resistance EN Fireine x Heavy A0608 Fireine x Heavy A060 Fireine x Heavy A06 NBS work section K0 - Plasterboard drylinings / partitions / ceilings 66

9 T F E bgtechnical.enquiries@bpb.com BS Table b 0mm Gypframe C Studs - single layer board linings One layer of board each side of 0mm Gypframe C Studs at 600mm centres. One layer of board each side of 0mm Gypframe C Studs at 600mm centres. mm Isover APR 00 in the cavity. One layer of board each side of 0mm Gypframe C Studs at 600mm centres. 0mm Isover APR 00 in the cavity. One layer of board each side of 0mm Gypframe C Studs at 600mm centres. 0mm stone mineral wool (min. kg/m ) in the cavity. type thickness thickness weight partition height R w rating reference mm mm kg/m mm db 0 minutes fire resistance BS WallBoard x Medium A060 WallBoard x Medium A060 SoundBloc x Medium A066 SoundBloc x Heavy A066 WallBoard x Medium A060 SoundBloc x Heavy A069 SoundBloc x Medium A0696 WallBoard x Medium A0606 SoundBloc x Medium A068 WallBoard x Medium A069 WallBoard x Medium A minutes fire resistance BS Fireine x Heavy A0608 Fireine x Heavy A060 Fireine x Heavy A06 Fireine x Medium A060 Based on a limiting deflection of /0 at 00Pa. NBS work section K0 - Plasterboard drylinings / partitions / ceilings 6

10 Performance ( EN Refer to - Basic principles of system design) Table a 0mm Gypframe C Studs - double layer board linings Two layers of board each side of 0mm Gypframe C Studs at 600mm centres. Two layers of board each side of 0mm Gypframe C Studs at 600mm centres. mm Isover APR 00 in the cavity. Two layers of board each side of 0mm Gypframe C Studs at 600mm centres. 0mm Isover APR 00 in the cavity. type thickness thickness weight partition height R w rating reference mm mm kg/m mm db 0 minutes fire resistance EN WallBoard x. 600 Severe A060 SoundBloc x Severe A0666 WallBoard x Severe A060 SoundBloc x. 600 Severe A0698 SoundBloc x. 600 Severe A060 WallBoard x Severe A06 60 minutes fire resistance EN WallBoard x Severe A0606 SoundBloc x 900 Severe A066 SoundBloc x Severe A0666 SoundBloc x. 000 Severe A0698 WallBoard x Severe A0608 SoundBloc x 000 Severe A0699 SoundBloc x. 000 Severe A060 WallBoard x Severe A06 90 minutes fire resistance EN SoundBloc x 000 Severe A066 Fireine x Severe A0609 SoundBloc x 000 Severe A0699 Fireine x Severe A06 SoundBloc x Severe A06 Fireine x Severe A06 0 minutes fire resistance EN Fireine x Severe A0609 Fireine x Severe A06 Fireine x Severe A06 Fireine x Severe A06 Fireine x Severe A06 The maximum heights quoted are limited by the fire state field of application or by limiting deflection of /0 at 00Pa, whichever is the more onerous. NB For heights between 00mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel (DC) should be used at head and base. NBS work section K0 - Plasterboard drylinings / partitions / ceilings 68

11 T F E bgtechnical.enquiries@bpb.com BS Table b 0mm Gypframe C Studs - double layer board linings Two layers of board each side of 0mm Gypframe C Studs at 600mm centres. Two layers of board each side of 0mm Gypframe C Studs at 600mm centres. mm Isover APR 00 in the cavity. Two layers of board each side of 0mm Gypframe C Studs at 600mm centres. 0mm Isover APR 00 in the cavity. type thickness thickness weight partition height R w rating reference mm mm kg/m mm db 60 minutes fire resistance BS WallBoard x. 600 Severe A060 SoundBloc x Severe A0666 WallBoard x Severe A060 SoundBloc x. 600 Severe A0698 WallBoard x Severe A06 SoundBloc x. 600 Severe A minutes fire resistance BS Based on a limiting deflection of /0 at 00Pa. WallBoard x Severe A0606 SoundBloc x 900 Severe A066 WallBoard x Severe A0608 SoundBloc x 900 Severe A0699 SoundBloc x Severe A06 0 minutes fire resistance BS MultiBoard x Severe G060 Fireine x Severe A0609 Fireine x Severe A06 Fireine x Severe A06 NB For heights between 00mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel (DC) should be used at head and base. NBS work section K0 - Plasterboard drylinings / partitions / ceilings 69

12 Performance ( EN Refer to - Basic principles of system design) Table a 0mm Gypframe AcouStuds - single and double layer board linings One layer of board each side of 0mm Gypframe 0 AS 0 AcouStuds at 600mm centres. One layer of board each side of 0mm Gypframe 0 AS 0 AcouStuds at 600mm centres. mm Isover APR 00 in the cavity. One layer of board each side of 0mm Gypframe 0 AS 0 AcouStuds at 600mm centres. 0mm Isover APR 00 in the cavity. 6 One layer of board each side of 0mm Gypframe 0 AS 0 AcouStuds at 600mm centres. x mm Isover APR 00 in the cavity. Two layers of board each side of 0mm Gypframe 0 AS 0 AcouStuds at 600mm centres. Two layers of board each side of 0mm Gypframe 0 AS 0 AcouStuds at 600mm centres. mm Isover APR 00 in the cavity. type thickness thickness weight partition height R w rating reference mm mm kg/m mm db 0 minutes fire resistance EN WallBoard x Medium A06A0 WallBoard x Medium A06A0 SoundBloc x Medium A06A6 SoundBloc x Medium A06A96 WallBoard x Medium A06A8 WallBoard x Medium A06A9 SoundBloc x Medium A06A8 SoundBloc x Heavy A06A WallBoard x. 00 Severe A06A0 60 minutes fire resistance EN Fireine x Heavy A06A08 SoundBloc x. 00 Severe A06A66 6 SoundBloc x Severe A06A98 90 minutes fire resistance EN 6 SoundBloc x 000 Severe A06A6 Fireine x Severe A06A09 Fireine x Severe A06A 0 minutes fire resistance EN 6 Fireine x Severe A06A09 Fireine x Severe A06A Fireine x Severe A06A The maximum heights quoted are limited by the fire state field of application or by limiting deflection of /0 at 00Pa, whichever is the more onerous. NB For heights between 00mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel (DC) should be used at head and base. NBS work section K0 - Plasterboard drylinings / partitions / ceilings 0

13 T F E bgtechnical.enquiries@bpb.com BS Table b 0mm Gypframe AcouStuds - single and double layer board linings One layer of board each side of 0mm Gypframe 0 AS 0 AcouStuds at 600mm centres. One layer of board each side of 0mm Gypframe 0 AS 0 AcouStuds at 600mm centres. mm Isover APR 00 in the cavity. One layer of board each side of 0mm Gypframe 0 AS 0 AcouStuds at 600mm centres. 0mm Isover APR 00 in the cavity. 6 One layer of board each side of 0mm Gypframe 0 AS 0 AcouStuds at 600mm centres. x mm Isover APR 00 in the cavity. Two layers of board each side of 0mm Gypframe 0 AS 0 AcouStuds at 600mm centres. Two layers of board each side of 0mm Gypframe 0 AS 0 AcouStuds at 600mm centres. mm Isover APR 00 in the cavity. type thickness thickness weight partition height R w rating reference mm mm kg/m mm db 0 minutes fire resistance BS 6 WallBoard x Medium A06A0 SoundBloc x Medium A06A6 SoundBloc x Medium A06A96 WallBoard x Medium A06A8 SoundBloc x Medium A06A8 SoundBloc x Heavy A06A 60 minutes fire resistance BS Fireine x Heavy A06A08 SoundBloc x. 00 Severe A06A66 WallBoard x. 00 Severe A06A0 SoundBloc x Severe A06A98 90 minutes fire resistance BS SoundBloc x 000 Severe A06A6 0 minutes fire resistance BS 6 Fireine x Severe A06A09 Fireine x Severe A06A Based on a limiting deflection of /0 at 00Pa. NB For heights between 00mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel (DC) should be used at head and base. NBS work section K0 - Plasterboard drylinings / partitions / ceilings

14 Performance ( EN Refer to - Basic principles of system design) Table a 9mm Gypframe C Studs - single and double layer board linings One layer of board each side of Two layers of board each side of 9mm Gypframe C Studs at 9mm Gypframe C Studs at 600mm centres. x mm 600mm centres. x mm Isover APR 00 in the cavity. Isover APR 00 in the cavity. type thickness thickness weight partition height R w (R w + Ctr) rating reference mm mm kg/m mm db 0 minutes fire resistance EN SoundBloc x Medium A06 The maximum heights quoted are limited by the fire state field of application or by limiting deflection of /0 at 00Pa, whichever is the more onerous. NB SoundBloc x 000 Heavy A06 60 minutes fire resistance EN SoundBloc x () Severe A06 90 minutes fire resistance EN SoundBloc x (0) Severe A06 For heights between 00mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel (DC) should be used at head and base. NBS work section K0 - Plasterboard drylinings / partitions / ceilings

15 T F E bgtechnical.enquiries@bpb.com BS Table b 9mm Gypframe C Studs - single and double layer board linings One layer of board each side of Two layers of board each side of 9mm Gypframe C Studs at 9mm Gypframe C Studs at 600mm centres. x mm 600mm centres. x mm Isover APR 00 in the cavity. Isover APR 00 in the cavity. type thickness thickness weight partition height R w (R w + Ctr) rating reference mm mm kg/m mm db 0 minutes fire resistance BS SoundBloc x Medium A06 SoundBloc x 00 Heavy A06 60 minutes fire resistance BS SoundBloc x () Severe A06 90 minutes fire resistance BS SoundBloc x (0) Severe A06 Based on a limiting deflection of /0 at 00Pa. NB For heights between 00mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel (DC) should be used at head and base. NBS work section K0 - Plasterboard drylinings / partitions / ceilings

16 Performance ( EN Two layers of board each side of 6mm Gypframe C Studs at 600mm centres. Refer to - Basic principles of system design) Table 6a 6mm Gypframe C Studs - double layer board linings Two layers of board each side of 6mm Gypframe C Studs at 600mm centres. mm Isover APR 00 in the cavity. Two layers of board each side of 6mm Gypframe C Studs at 600mm centres. 0mm Isover APR 00 in the cavity. Inner layer of Gyproc Plank fixed horizontally, and outer layer of Gyproc Fireine fixed vertically each side of 6mm Gypframe C Studs at 600mm centres. mm Isover APR 00 in the cavity. type thickness thickness weight partition height R w (R w + Ctr) rating reference mm mm kg/m mm db 0 minutes fire resistance EN WallBoard x Severe A060 SoundBloc x Severe A068 WallBoard x Severe A0609 SoundBloc x (9) Severe A060 WallBoard x Severe A minutes fire resistance EN SoundBloc x Severe A068 WallBoard x Severe A0608 SoundBloc x (0) Severe A069 SoundBloc x (9) Severe A060 WallBoard x Severe A06060 Fireine x Severe A06 WallBoard x Severe A060 WallBoard x Severe A069 Plank+Fireine Severe A minutes fire resistance EN SoundBloc x (0) Severe A069 Fireine x Severe A0609 SoundBloc x () Severe A06 Fireine x Severe A06 SoundBloc x () Severe A06 Fireine x Severe A06 Plank+Fireine Severe A600 0 minutes fire resistance EN Fireine x Severe A0609 Fireine x Severe A0680 Fireine x Severe A06 Fireine x Severe A068 Fireine x Severe A06 Fireine x Severe A06 The maximum heights quoted are limited by the fire state field of application or by limiting deflection of /0 at 00Pa, whichever is the more onerous. NB For heights between 00mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel (DC) should be used at head and base. NBS work section K0 - Plasterboard drylinings / partitions / ceilings

17 T F E bgtechnical.enquiries@bpb.com BS Table 6b 6mm Gypframe C Studs - double layer board linings Two layers of board each side of 6mm Gypframe C Studs at 600mm centres. Two layers of board each side of 6mm Gypframe C Studs at 600mm centres. mm Isover APR 00 in the cavity. Two layers of board each side of 6mm Gypframe C Studs at 600mm centres. 0mm Isover APR 00 in the cavity. Inner layer of Gyproc Plank fixed horizontally, and outer layer of Gyproc Fireine fixed vertically each side of 6mm Gypframe C Studs at 600mm centres. mm Isover APR 00 in the cavity. type thickness thickness weight partition height R w (R w + Ctr) rating reference mm mm kg/m mm db 60 minutes fire resistance BS WallBoard x Severe A060 SoundBloc x Severe A068 WallBoard x Severe A0609 SoundBloc x (9) Severe A060 WallBoard x Severe A069 SoundBloc x (0) Severe A06 90 minutes fire resistance BS WallBoard x Severe A0608 SoundBloc x (0) Severe A069 WallBoard x Severe A06060 SoundBloc x () Severe A06 SoundBloc x () Severe A06 Plank+SoundBloc Severe A600 0 minutes fire resistance BS Fireine x Severe A0609 MultiBoard x Severe G060 Fireine x Severe A06 Fireine x Severe A06 Plank+Fireine Severe A600 Based on a limiting deflection of /0 at 00Pa. NB For heights between 00mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel (DC) should be used at head and base. NBS work section K0 - Plasterboard drylinings / partitions / ceilings

18 Performance ( EN Refer to - Basic principles of system design) Table a 6mm Gypframe AcouStuds - double layer board linings Two layers of board each side of 6mm Gypframe 6 AS 0 AcouStuds at 600mm centres. Two layers of board each side of 6mm Gypframe 6 AS 0 AcouStuds at 600mm centres. 0mm Isover APR 00 in the cavity. type thickness thickness weight partition height R w (R w + Ctr) rating reference mm mm kg/m mm db 60 minutes fire resistance EN The maximum heights quoted are limited by the fire state field of application or by limiting deflection of /0 at 00Pa, whichever is the more onerous. NB WallBoard x () Severe A06A08 SoundBloc x () Severe A06A9 90 minutes fire resistance EN SoundBloc x () Severe A06A9 SoundBloc x (6) Severe A06A Fireine x (8) Severe A06A09 0 minutes fire resistance EN Fireine x (8) Severe A06A09 Fireine x () Severe A06A80 For heights between 00mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel (DC) should be used at head and base. NBS work section K0 - Plasterboard drylinings / partitions / ceilings 6

19 T F E bgtechnical.enquiries@bpb.com BS Table b 6mm Gypframe AcouStuds - double layer board linings Two layers of board each side of 6mm Gypframe 6 AS 0 AcouStuds at 600mm centres. Two layers of board each side of 6mm Gypframe 6 AS 0 AcouStuds at 600mm centres. 0mm Isover APR 00 in the cavity. type thickness thickness weight partition height R w (R w + Ctr) rating reference mm mm kg/m mm db 90 minutes fire resistance BS Based on a limiting deflection of /0 at 00Pa. NB WallBoard x Severe A06A08 SoundBloc x Severe A06A9 SoundBloc x (6) Severe A06A 0 minutes fire resistance BS Fireine x Severe A06A09 For heights between 00mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel (DC) should be used at head and base. NBS work section K0 - Plasterboard drylinings / partitions / ceilings

20 Design Planning - key factors The position of services and heavy fixtures should be pre-determined and their installation planned into the frame erection stage. Wind loading GypWall partitions are non-loadbearing but can accept a degree of wind loading, for example when used in buildings with large or multiple external doors. Refer to. Robustness. Cavity fire barriers Minimum.mm Gyproc plasterboard, screw-fixed into the web of perimeter channels or vertical studs, will provide a satisfactory closure to flame or smoke. Refer to Cavity fire barriers. Services Penetrations Penetrations of fire-resistant or sound-insulating constructions for services need careful consideration to ensure that the performance of the element is not downgraded and also that the services themselves do not act as the mechanism of fire spread or sound transmission. Refer to. Service installations. Independent support When designing for the installation of services such as fire dampers and associated ductwork through a GypWall partition, consideration should be given to the size and weight of the damper - this will determine whether it can be supported directly from the partition or needs to be independently supported from the structure. Refer to. Service installations. Electrical The installation of electrical services should be carried out in accordance with the recommendations of the Institution of Electrical Engineers. The cut-outs in the studs can be used for routing electrical and other small services (see Construction details - ). Switch boxes and socket outlets can be supported from Gypframe 99 FC 0 Fixing Channel fixed horizontally between studs, or a high performance socket box detail used where higher acoustic performance is required. Where Gypframe AcouStuds are used, services are routed through 0mm x 8mm H shaped push-outs, at the same centres as shown in Construction details - for conventional cut-outs. Cables should be protected by conduit, or other suitable precautions taken to prevent abrasion when they pass through the metal frame. Fixing floor and ceiling channels Floor channels must be securely fixed with a row of fixings at 600mm maximum centres. With 9mm and 8mm channels, two rows of staggered fixings are required, each row at 600mm centres and each fixing mm in from the flange. If the floor is uneven, a 8mm thick timber sole plate equal to the width of the channel should be used. If the concrete or screeded floor is new, consideration should be given to the installation of a damp proof membrane between the floor surface and the channel or sole plate. Ceiling channels must be securely fixed at 600mm maximum centres. With 9mm and 8mm channels, two rows of staggered fixings are required, each row at 600mm centres and each fixing mm in from the flange. Extra support may be necessary to provide positive fixing points with some constructions. Door openings The designer should consider thickness tolerances of the partition types in relation to the proposed door frame detail. Standard door frame detailing to suit BS ight and Medium Duty applications is shown in Construction details -. Detailing to satisfy BS : 99 requirements for Heavy and Severe Duty is shown in Construction details -. Where additional provision is required to support heavy doorsets contact the British Gypsum Drywall Academy Technical Advice Centre for guidance. The door manufacturer should also be consulted in relation to door details. Framing surround for openings Where services such as horizontal ducts, fire dampers and access panels are required to penetrate the wall, their position should be predetermined in order that a framed opening can be provided. The openings should be constructed using established metal stud procedures. See Construction details - -. Control joints Control joints may be required in the partition to relieve stresses induced by expansion and contraction of the structure (see Construction details - ). They should coincide with movement joints within the surrounding structure. Deflection heads Partition head deflection designs may be necessary to accommodate deflections in the supporting floor. Deflection heads may also be required to the underside of roof structures subjected to positive and negative pressures. Refer to Construction details For special detailing which minimises the loss of acoustic performance: Refer to Basic principles of system design. Access for maintenance Where access is required within the partition, to maintain services for example, Gyproc Profilex Access Panels should be used. Fixtures ightweight fixtures can be made directly to the partition linings. Medium weight fixtures can be made to Gypframe 99 FC 0 Fixing Channel. Heavy fixtures should be made to the metal studs or independent framing installed before boarding. Refer to.. Robustness, Fixings into drywall systems. Board finishing Refer to 0 Finishing systems and decorative effects. Please refer to - Basic principles of system design for general guidance. 8

21 T F E bgtechnical.enquiries@bpb.com Construction details Service cut-outs (all dimensions in mm) 00 Centres at 600mm thereafter a Service cut-outs - Gypframe AcouStuds 00 Centres at 600mm thereafter mm stud Head and base 60mm stud 0mm stud 9mm stud 6mm stud mm AcouStud 0mm AcouStud 6mm AcouStud Internal wall junction - stud to wall and stop end detail Gyproc Sealant Internal blockwork Gyproc or Glasroc plasterboard Where partition / ceiling junction is not finished apply Gyproc Sealant. Gypframe stud (fixed at 600mm centres) Bulk fill with Gyproc jointing materials NB Service cut-out dimensions are the same for Gypframe C and I Studs. 9

22 T junction detail when acoustic performance is a key consideration - helps to reduce flanking transmission Junction with external wall 6 6 Standard T junction (single layer) Gypframe 99 FC 0 Fixing Channel (short legs flattened at stud positions) 8 Corner detail (single layer) 9 Corner detail (double layer) 6 Gypframe GA Internal Fixing Angle Gypframe Wafer Head Screw (two fixings per stud position) Gyproc or Glasroc plasterboard Gypframe stud Isover insulation Gyproc Dri-Wall Adhesive Gyproc Thermaine laminate 80

23 T F E bgtechnical.enquiries@bpb.com 0 Splayed corner detail. Gypframe GA6 Splayed Angle is also required on the inside of the splayed corner of a fire-rated partition. Typical control joint (dimensions in mm) Crimped Gypframe 6 S 0 C Stud to Gypframe Deep Typical sound resisting wall head detail (e.g. Gypframe Flange Floor & Ceiling Channel (DC) when partition heights 6 S 0 C Stud, Gyproc Plank and Gyproc SoundBloc are greater than 00mm linings) Stone mineral wool (minimum density kg/m ) 6 Roof trusses Gyproc Control Joint Gyproc or Glasroc plasterboard Isover insulation 8 Gypframe C Stud 9mm plywood 9 Skirting Ceiling Channel (Gypframe 8 DC 60 Deep Flange Floor 0 Gypframe GA6 Splayed Angle & Ceiling Channel) ock using a Gyproc crimping tool Isover insulation used as a cavity barrier NB Where 6mm studs are used at heights greater than 000mm, lock into floor and ceiling channels using a Gyproc crimping tool. 8

24 Standard door frame to satisfy BS : Parts & : 99 - ight and Medium Duty Standard door frame to satisfy BS : Parts & : 99 - Heavy and Severe Duty Head of door frame Base of door frame Section A-A 6 A 0mm A Gypframe C Stud Gypframe Standard Floor & Ceiling Channel (to sleeve stud) Gypframe Standard Floor & Ceiling Channel snipped and bent to 90º, crimped or screw-fixed to the stud Gyproc or Glasroc plasterboard Timber door frame (by others) 6 Floor channel fixings NB The studs each side of the opening are sleeved to full door height with Gypframe Standard Floor & Ceiling Channel. The Gypframe channel is cut 00mm short to allow for the extension of floor channel, which is cut, bent, and interleaved as shown in section A-A, and then fixed twice to each side. At the head, the channel is cut and bent to extend 0mm down the face of the studs, and fixed twice to each side. NB Advice should be sought from the door manufacturer prior to the construction of these details. 8

25 T F E bgtechnical.enquiries@bpb.com 6 Deflection head 60 minutes fire resistance, mm downward deflection 8 mm mm 0mm Deflection head up to 0 minutes fire resistance, mm downward deflection 8 mm mm 0 mm (bottom of channel to top of stud nogging) 6 8 Deflection head 60 minutes, plus or minus mm 9 Deflection head 60 minutes fire resistance, 0mm downward deflection mm mm 0mm 0mm 9 9 0mm mm 0 Deflection head 60 minutes, plus or minus mm Deflection head 60 minutes, 0mm downward deflection 8 8 mm mm 0mm 0mm 0mm mm Gyproc FireStrip (continuous line) Gyproc CoreBoard Gypframe Deep Flange Floor & Ceiling Channel (DC) Gypframe GFS Fixing Strap 8 9 Head channel fixing through firestop into structure at 600mm max. centres Gypframe Extra Deep Flange Floor & Ceiling Channel (EDC) fixed to timber head plate at 600mm centres 6 Timber head plate (softwood) Stone mineral wool (minimum kg / m ) retained by stud nogging Gyproc or Glasroc plasterboard 0 Nogging cut from Gypframe C Stud Head plate fixing to structure mm Glasroc FireCase S Gypframe Extra Deep Flange Floor & Ceiling Channel (EDC) NB No fixings should be made through the boards into the flanges of the head channel The arrow ( ) denotes the position of the uppermost board fixing, which should be made into Gypframe GFS Fixing Strap (or stud nogging in Construction details - ). Continuous Gyproc FireStrip must be installed as shown in order to maintain fire performance. Where there is a need for a deflection head in a 90 minute wall, the 0 minute solution can be used (refer to Construction details - ) or alternatively, please contact the British Gypsum Drywall Academy Technical Advice Centre for further guidance. 8

26 Opening for service penetrations in fire-rated partitions Elevation Section X Section Y Fire tested construction in which the damper is supported by the partition (isometric view) Stone mineral wool (80kg/m ) Gyproc or Glasroc plasterboard Damper (by others). Maximum weight of damper should not exceed kg. Maximum size of damper should not exceed 00 x 00mm. Gypframe stud Gypframe Floor & Ceiling Channel (cloaking stud in Section Y) NB Consult British Gypsum for guidance on independent support requirements for service penetrations. 8

27 T F E bgtechnical.enquiries@bpb.com Board layout - typical configuration Inner layer board Face (second layer) board Gypframe GFS Fixing Strap or Gypframe GFT Fixing T Gypframe metal framing Gyproc Drywall Screws 8

GypWall QUIET Acoustic separating wall system

GypWall QUIET Acoustic separating wall system Acoustic separating wall system Putney Wharf, South London Acoustic separating wall system is a lightweight, non-loadbearing, twin-framed acoustic separating wall. Primarily used as sound resisting walls

More information

GypLyner IWL Independent wall lining system

GypLyner IWL Independent wall lining system Independent wall lining system Photograph courtesy of Philip Brier 0 Independent wall lining system independent wall lining is a lightweight, nonloadbearing drylining which is erected independently of

More information

The extra strong, extra durable, sound resistant system that you can direct fix to

The extra strong, extra durable, sound resistant system that you can direct fix to C0 Partitions The extra strong, extra durable, sound resistant system that you can direct fix to All our systems are covered by SpecSure when using genuine Gyproc and Isover products gyproc.ie Utilising

More information

GypWall AUDIO The ultimate sound insulating wall system

GypWall AUDIO The ultimate sound insulating wall system The ultimate sound insulating wall system Cineworld, Ilford 8 The ultimate sound insulating wall system is a non-loadbearing, twin frame high performance wall system that provides exceptionally high levels

More information

GypWall QUIET Acoustic separating wall system

GypWall QUIET Acoustic separating wall system Acoustic separating wall system 90 Al Mafraq Hospital, Abu Dhabi 0 R w db 90 0 mins is a lightweight, non-loadbearing, twin framed acoustic separating wall, primarily used as a sound resisting wall in

More information

Staggered stud acoustic partition system

Staggered stud acoustic partition system GypWall STAGGERED GypWall STAGGERED Staggered stud acoustic partition system GypWall STAGGERED is a nonloadbearing metal stud partition which provides very high levels of sound insulation. In public and

More information

GypWall RAPID db Plus

GypWall RAPID db Plus Metal stud housing partition system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated 0/0/00

More information

GypWall AUDIO The ultimate cinema wall system

GypWall AUDIO The ultimate cinema wall system The ultimate cinema wall system 9 Vox Cinemas, Muscat City Centre - Sultanate of Oman 7 0 R w db 0 0 mins is a non-loadbearing, twin frame high performance wall system that provides exceptionally high

More information

GypWall TM ROBUST 4.4. GypWall ROBUST. Durable impact resistant partition system. Key facts. Sector Guide

GypWall TM ROBUST 4.4. GypWall ROBUST. Durable impact resistant partition system. Key facts. Sector Guide GypWall TM ROBUST GypWall ROBUST is a high impact resistant partition system for use where a more durable structure is required. The system provides a lightweight, cost-effective, non-loadbearing partition

More information

C05. S03. P02 P08 FireWall

C05. S03. P02 P08 FireWall ! This section includes updated information, added since it was first published in December 2015. Last updated 16/12/2016 C05. S03. P02 P08 Including C05. S01. P02 Specialist partitions introduction C05

More information

C04. S05. P02 P14 GypWall quiet sf

C04. S05. P02 P14 GypWall quiet sf ! This section includes updated information, added since it was first published in December 0. Last updated 0//07 C0. S0. P0 P Including C0. S0. P0 P8 Partitions introduction C0 Partitions Single frame

More information

Staggered stud acoustic partition system

Staggered stud acoustic partition system C0 Partitions Staggered stud acoustic partition system All our systems are covered by SpecSure when using genuine Gyproc and Isover products is a non-loadbearing stud partition incorporating a single framework

More information

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner UNIVERSAL Metal framed wall lining system Metal framed wall lining system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated 0/0/00 Cadbury

More information

Single frame acoustic separating wall system

Single frame acoustic separating wall system C0 Partitions Single frame acoustic separating wall system All our systems are covered by SpecSure when using genuine Gyproc and Isover products gyproc.ie is a non-loadbearing partition, which provides

More information

C05. S03. P02 P08 FireWall

C05. S03. P02 P08 FireWall ! This section includes updated information, added since it was first published in December 2015. Last updated 29/03/2018 C05. S03. P02 P08 Including C05. S01. P02 Specialist partitions introduction C05

More information

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner UNIVERSAL Metal framed wall lining system Metal framed wall lining system Pizza Express, York 30 Metal framed wall lining system wall lining system is a cost-effective, virtually independent metal frame drylining. It is a general purpose system

More information

Independent twin frame high performance acoustic separating wall system

Independent twin frame high performance acoustic separating wall system C04 Partitions Independent twin frame high performance acoustic separating wall system All our systems are covered by SpecSure when using genuine Gyproc and Isover products is a lightweight, non-loadbearing

More information

C04. S11. P02 P13 Non-loadbearing timber stud

C04. S11. P02 P13 Non-loadbearing timber stud ! This section includes updated information, added since it was first published in December 0. Last updated 6//06 C0. S. P0 P Non-loadbearing timber stud Including C0. S0. P0 P8 Partitions introduction

More information

Curved partition and wall lining system

Curved partition and wall lining system C05 Specialist partitions Curved partition and wall lining system All our systems are covered by SpecSure when using genuine Gyproc and Isover products is a lightweight system specifically designed to

More information

The ultimate impact resistant partition

The ultimate impact resistant partition GypWall EXTREME GypWall EXTREME The ultimate impact resistant partition GypWall EXTREME is Gypsum Industries ultimate impact resistant partition system for use where even severe duty won t suffice. It

More information

Single frame acoustic separating wall system

Single frame acoustic separating wall system GypWall QUIET SF GypWall QUIET SF Single frame acoustic separating wall system GypWall QUIET SF metal stud partition is a lightweight, non-loadbearing, single frame wall system. Subject to Local Authority

More information

The ultimate sound insulating wall system

The ultimate sound insulating wall system C0 Partitions The ultimate sound insulating wall system All our systems are covered by SpecSure when using genuine Gyproc and Isover products is a non-loadbearing, twin-frame high performance wall system

More information

GypWall TM EXTREME. GypWall EXTREME 4.5. Ultimate impact and abrasion resistant partition system. Key facts. Sector Guide

GypWall TM EXTREME. GypWall EXTREME 4.5. Ultimate impact and abrasion resistant partition system. Key facts. Sector Guide GypWall TM EXTREME GypWall EXTREME is an ultimate impact resistant partition system for use where even severe duty will not suffice. The system provides a lightweight, cost-effective, non-loadbearing partition

More information

FireWall. High performance fire-resistant wall system. FireWall.

FireWall. High performance fire-resistant wall system. FireWall. FireWall FireWall High performance fire-resistant wall system FireWall is a non-loadbearing wall which provides up to 240 minutes fire resistance. It is used in certain ground floor basement situations

More information

GypLyner UNIVERSAL Concealed grid ceiling lining system

GypLyner UNIVERSAL Concealed grid ceiling lining system Concealed grid ceiling lining system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated 0/07/00

More information

ShaftWall. Shaft and duct encasement system. ShaftWall.

ShaftWall. Shaft and duct encasement system. ShaftWall. ShaftWall ShaftWall Shaft and duct encasement system ShaftWall provides a lightweight, non-loadbearing fire-resistant structure to protect elements within the service cores of modern fast-track developments.

More information

GypLyner UNIVERSAL (Ceilings)

GypLyner UNIVERSAL (Ceilings) (Ceilings) Concealed grid ceiling lining system ceiling is a general purpose ceiling lining system suitable for most internal applications. It is used in all types of buildings, from residential properties

More information

C05. S02. P02 P30 ShaftWall

C05. S02. P02 P30 ShaftWall ! This section includes updated information, added since it was first published in December 0. Last updated 0//0 C0. S0. P0 P0 Including C0. S0. P0 Specialist partitions introduction C0 Specialist partitions

More information

GypLyner UNIVERSAL Concealed grid ceiling lining system

GypLyner UNIVERSAL Concealed grid ceiling lining system Concealed grid ceiling lining system The Sage, Gateshead 9 Concealed grid ceiling lining system ceiling is a general purpose ceiling lining system suitable for most internal applications. It is used in

More information

CO5. Specialist partitions C05. Introduction - ShaftWall 29/03/2018 FireWall 29/03/2018 GypWall curve 16/12/2016 GypWall secure 29/03/2018 BlastWall -

CO5. Specialist partitions C05. Introduction - ShaftWall 29/03/2018 FireWall 29/03/2018 GypWall curve 16/12/2016 GypWall secure 29/03/2018 BlastWall - ! This section includes updated information, added since it was first published in December 05. Section Last updated Introduction - ShaftWall 9/0/08 FireWall 9/0/08 GypWall curve 6//06 GypWall secure 9/0/08

More information

Tiling Tiling

Tiling Tiling 416 Tiles can be applied to drylined walls or the surface of lightweight partition systems to dado level or above. can be carried out in any type of building either in dry areas or in areas subject to

More information

CasoLine MF Concealed grid MF suspended ceiling system

CasoLine MF Concealed grid MF suspended ceiling system Concealed grid MF suspended ceiling system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated

More information

ShaftWall. Shaft and duct encasement system. ShaftWall.

ShaftWall. Shaft and duct encasement system. ShaftWall. ShaftWall ShaftWall Shaft and duct encasement system ShaftWall provides a lightweight, non-loadbearing fire-resistant structure to protect elements within the service cores of modern fast-track developments.

More information

October Plasterboard baffle. Hilti CP617 Putty Pad. Socket detailing. White Book supplement

October Plasterboard baffle. Hilti CP617 Putty Pad. Socket detailing. White Book supplement October 006 Plasterboard baffle Hilti CP67 Putty Pad White Book supplement Internal partition system socket detailing Internal partition system socket detailing Fixing electrical socket boxes into British

More information

CasoLine MF Concealed grid MF suspended ceiling system

CasoLine MF Concealed grid MF suspended ceiling system Concealed grid MF suspended ceiling system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated

More information

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products. GypLyner GypLyner Metal framed wall lining system All our systems are covered by SpecSure when using genuine Gyproc and Isover products Linings GypLyner GypLyner is a cost-effective, virtually independent

More information

Issue date: 15th January Key changes since original publication (July 2005):

Issue date: 15th January Key changes since original publication (July 2005): Issue date: th January 007 Key changes since original publication (July 00): January 007 Page 7 MultiBoard detail (G00) deleted from 0 minute specs in Table. Page 7 Floor depth column deleted from table.

More information

GypLyner (walls) Metal framed wall lining system. GypLyner.

GypLyner (walls) Metal framed wall lining system. GypLyner. GypLyner GypLyner (walls) Metal framed wall lining system GypLyner is a cost-effective, virtually independent metal frame drylining system for lining walls. General purpose and suitable for all internal

More information

Internal walls. Creating perfect living spaces. Technical Advice Centre Tel:

Internal walls. Creating perfect living spaces. Technical Advice Centre Tel: Internal walls 174 Technical Advice Centre Tel: 0844 800 1991 Legislation and guidance - National Building Regulations Approved Document E Approved Document E (ADE) gives guidance on how to provide reasonable

More information

Cavity fire barriers. Cavity fire barriers. Fire separation within concealed spaces. C06 Floors and ceilings

Cavity fire barriers. Cavity fire barriers. Fire separation within concealed spaces. C06 Floors and ceilings Fire separation within concealed spaces Regulatory requirements demand that cavities and concealed spaces, in the structure or fabric of a building, are sub-divided or sealed by means of cavity barriers

More information

Selecting floors and ceilings

Selecting floors and ceilings floors and ceilings email: bgtechnical.enquiries@bpb.com www.british-gypsum.com/health 89 floors and ceilings Introduction 9 Solutions - key systems 9 Solutions for concrete floors 9 - Dense slab 9 This

More information

C08. S04. P02 P08 Tiling

C08. S04. P02 P08 Tiling ! This section includes updated information, added since it was first published in December 2015. Last updated 29/03/2018 C08. S04. P02 P08 Including C08. S01. P02 Finishes introduction C08 Finishes Introduction

More information

GypLyner (Ceilings) Concealed grid ceiling lining system. GypLyner UNIVERSAL.

GypLyner (Ceilings) Concealed grid ceiling lining system. GypLyner UNIVERSAL. GypLyner UNIVERSAL GypLyner (Ceilings) Concealed grid ceiling lining system GypLyner ceiling is a general purpose ceiling lining system suitable for most internal applications. It is used in all types

More information

C06. S05. P02 P12 GypFloor silent

C06. S05. P02 P12 GypFloor silent ! This section includes updated information, added since it was first published in December 05. Last updated 6//06 C06. S05. P0 P GypFloor silent Including C06. S0. P0 P08 Floors and ceilings introduction

More information

C06. S05. P02 P12 GypFloor silent

C06. S05. P02 P12 GypFloor silent ! This section includes updated information, added since it was first published in December 05. Last updated 30/06/06 C06. S05. P0 P GypFloor silent Including C06. S0. P0 P08 Floors and ceilings introduction

More information

Quantity take-off details

Quantity take-off details Quantitiy take-off details 6 Quantity take-off details Quantities Choose system specification / height or area as required, as given in the left hand column. Read across the columns to determine the quantity

More information

Loadbearing timber joist floors

Loadbearing timber joist floors C06 Floors and ceilings Internal and separating floor systems Timber joists are widely used within internal floor and separating floor construction, both in residential and coercial applications. Our range

More information

Selecting partitions

Selecting partitions email: bgtechnical.enquiries@bpb.com www.british-gypsum.com/health Introduction 6 Performance matrix 8 Worked examples 0 your partition type Solutions up to R w db This section will guide you through the

More information

GypLyner framed structural steel encasement system

GypLyner framed structural steel encasement system GypLyner framed structural steel encasement system is a steel encasement system which provides a rapid method of cladding structural steel sections to provide up to 10 minutes fire resistance. The system

More information

C06. S06. P02 P20 Loadbearing timber joist floors

C06. S06. P02 P20 Loadbearing timber joist floors ! This section includes updated information, added since it was first published in December 05. Last updated 6//06 C06. S06. P0 P0 Loadbearing timber joist floors Including C06. S0. P0 P08 Floors and ceilings

More information

Gypframe profiles. Dimensional specifications

Gypframe profiles. Dimensional specifications Dimensional specifications Dimensional specifications data sheet Introduction Characteristics This data sheet contains the dimensional specification of the following Gypframe components Gypframe Studs,

More information

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250 FIRE PROTECTION GTEC Shaftwall range uses a specially designed system to protect voids and shafts in buildings. It resists pressure changes and enables installation from one side of the shaft only. GTEC

More information

Technical performance and principles of system design

Technical performance and principles of system design Service installations Technical Service installations Services within partitions and lining cavities The installation of electrical services must always be carried out strictly in accordance with the National

More information

Gypwall systems. incorporating Gyproc Habito

Gypwall systems. incorporating Gyproc Habito Gypwall systems incorpo Gyproc Habito Introduction Gyproc Habito is the next generation in plasterboard. Innovative technology combined with an exceptionally strong solid gypsum core have produced a board

More information

Separating walls. Countryside Properties, Lock 38, Stoke-on-Trent

Separating walls. Countryside Properties, Lock 38, Stoke-on-Trent Separating walls Countryside Properties, ock 8, Stoke-on-Trent Separating Masonry walls Walls Separating Masonry wallswalls Approved Document E 200 Clause E Approved Document 200 - Requirements Walls >>

More information

C07. S04. P02 P10 GypLyner universal

C07. S04. P02 P10 GypLyner universal ! This section includes updated information, added since it was first published in December 05. Last updated 4/06/07. S04. P0 P0 GypLyner universal Including. S0. P0 P04 Linings introduction Linings Introduction

More information

FlameLyner Industrial fire-resistant lining system

FlameLyner Industrial fire-resistant lining system 20 FlameLyner Industrial fire-resistant lining system FlameLyner Industrial fire-resistant lining system FlameLyner is used to line the external walls of steel framed industrial buildings. The system is

More information

Creating perfect living spaces. Shaping spaces for living, with internal lining solutions that enhance lifestyles. Creating perfect living spaces

Creating perfect living spaces. Shaping spaces for living, with internal lining solutions that enhance lifestyles. Creating perfect living spaces O7 Shaping spaces for living, with internal lining solutions that enhance lifestyles 171 Discover how we are working within the residential industry to facilitate differentiation, through new, innovative,

More information

DriLyner 5.2. DriLyner. Drywall masonry lining systems. Key facts. Sector Guide

DriLyner 5.2. DriLyner. Drywall masonry lining systems. Key facts. Sector Guide systems provide simple and effective techniques for fixing Gyproc plasterboards or Gyproc thermal laminates to brick, block, and concrete walls. They can be used in all building types in both new-build

More information

C09. S02. P02 P14 CasoLine mf

C09. S02. P02 P14 CasoLine mf ! This section includes updated information, added since it was first published in December 0. Last updated 9/0/08 C09. S0. P0 P Including C09. S0. P0 P08 Sound absorbing solutions introduction C09 Sound

More information

CO3. Steel encasements C03. Introduction - FireCase 01/12/2017 GypLyner encase 11/05/2017. Introduction Steel encasements

CO3. Steel encasements C03. Introduction - FireCase 01/12/2017 GypLyner encase 11/05/2017. Introduction Steel encasements ! This section includes updated information, added since it was first published in ecember 05. Section Last updated Introduction - FireCase 0//07 GypLyner encase /05/07 Introduction Steel encasements C03

More information

GypFloor SILENT 6.4. Sound insulating floor system. Key facts. Sector Guide

GypFloor SILENT 6.4. Sound insulating floor system. Key facts. Sector Guide is a sound insulating floor system designed for use in the residential sector. It is specified in conversion or improvement work to upgrade an existing timber joist floor to meet the acoustic requirements

More information

Tiling Tiling Finishes C08

Tiling Tiling Finishes C08 C08 Finishes In rooms subject to high or intermittent moisture conditions, the range of boards available for tiling offers flexibility of design and peace of mind when installed in both wall linings, lightweight

More information

Plasterboard selector guide Dedicated to plasterboard

Plasterboard selector guide Dedicated to plasterboard GYPROC Plasterboard selector guide Dedicated to plasterboard Dedicated to Plasterboard British Gypsum manufactured the first plasterboard in the UK over 90 years ago. Since then, we have developed this

More information

Gypframe profiles. Dimensional specifications

Gypframe profiles. Dimensional specifications Gypframe profiles Dimensional specifications Gypframe profiles Dimensional specifications data sheet Introduction This data sheet contains the dimensional specification of the following Gypframe components

More information

Gypframe profiles. Dimensional specifications

Gypframe profiles. Dimensional specifications Gypframe profiles Dimensional specifications Gypframe profiles Dimensional specifications data sheet Introduction This data sheet contains the dimensional specification of the following Gypframe components

More information

C06. S02. P02 P22 CasoLine mf

C06. S02. P02 P22 CasoLine mf ! This section includes updated information, added since it was first published in December 0. Last updated 6//06 C06. S0. P0 P CasoLine mf Including C06. S0. P0 P08 Floors and ceilings introduction C06

More information

CasoLine mf. Concealed monolithic metal frame suspended ceiling system

CasoLine mf. Concealed monolithic metal frame suspended ceiling system C0 Floors and ceilings Concealed monolithic metal frame suspended ceiling system All our systems are covered by SpecSure when using genuine Gyproc and Isover products is a suspended ceiling system suitable

More information

CasoLine GRID. Suspended grid ceiling system. The Manchester Academy

CasoLine GRID. Suspended grid ceiling system. The Manchester Academy Suspended grid ceiling system The Manchester Academy 0 Suspended grid ceiling system is a lightweight ceiling system available in concealed or eposed grid options. It presents an attractive pre-finished

More information

FireCase. Frameless structural steel encasement system. FireCase.

FireCase. Frameless structural steel encasement system. FireCase. Frameless structural steel encasement system frameless encasement system provides a high quality cladding to structural steel, and offers up to 10 minutes fire protection. The system affords protection

More information

22 The Lowry Centre, Salford

22 The Lowry Centre, Salford The Lowry Centre, Salford Glasroc F fire protection solutions Glasroc F board products FireCase GypWall CLASSIC 7 FireWall 88 Timber stud 9 GypWall CURVE 96 GypWall SECURE 99 BlastWall 0 FlameLyner 0 Cavity

More information

June Non - Residential New Build Partition walls

June Non - Residential New Build Partition walls June 2010 Non - Residential New Build 4.6.3 Partition walls Non-residential new build 4.0 Non-residential New Build Partition Walls Contents Introduction find online page Solution optimiser and pathfinder

More information

CO9. Sound absorbing solutions C09

CO9. Sound absorbing solutions C09 ! This section includes updated information, added since it was first published in December 05. Section Last updated Introduction /0/06 CasoLine mf /05/07 CasoLine curve /05/07 GypLyner universal /05/07

More information

Tiling. Capital Gate Hotel, Abu Dhabi - UAE

Tiling.  Capital Gate Hotel, Abu Dhabi - UAE 166 202 Capital Gate Hotel, Abu Dhabi - UAE Tiles can be applied to drylined walls or to the surface of lightweight partition systems. can be carried out in any type of building, either in dry areas or

More information

SOUND SOLUTIONS FOR YOUR HOME. Controlling the volume of everyday living How to solve a problem you have with noise

SOUND SOLUTIONS FOR YOUR HOME. Controlling the volume of everyday living How to solve a problem you have with noise SOUND SOLUTIONS FOR YOUR HOME Controlling the volume of everyday living How to solve a problem you have with noise How to reduce unwanted noise within your home Improve your home s sound insulation for

More information

GypWall Secure Systems

GypWall Secure Systems GypWall Secure Systems This is a lightweight, non load bearing security wall system, offering high resistance to determined attack. Key facts Minimal wall thickness Tested in accordance with SANS 10177:2

More information

SOUND SOLUTIONS FOR YOUR HOME. Controlling the volume of everyday living How to solve a problem you have with noise

SOUND SOLUTIONS FOR YOUR HOME. Controlling the volume of everyday living How to solve a problem you have with noise SOUND SOLUTIONS FOR YOUR HOME Controlling the volume of everyday living How to solve a problem you have with noise How to reduce unwanted noise within your home Improve your home s sound insulation for

More information

promise Comprises only the highest quality components, designed to work individually and together to deliver the specified level of performance.

promise Comprises only the highest quality components, designed to work individually and together to deliver the specified level of performance. Trade Catalogue 2012 SpecSure Contacts SpecSure SpecSure is a unique 'off the shelf' warranty to end users that confirms British Gypsum proprietary systems will perform to the parameters published in our

More information

WALLS GYPWALL FIRESTOP WALLS 25 GYPWALL FIRESTOP KEY FACTS

WALLS GYPWALL FIRESTOP WALLS 25 GYPWALL FIRESTOP KEY FACTS WALLS GYPWALL FIRESTOP Is a non-load bearing high performance fire resistance system providing a fire rating of up to 60 minutes. Used in retail environments, storage areas and residential applications.

More information

Assessment Number BTC 16422FA

Assessment Number BTC 16422FA Assessment Number BTC 16422FA A FIRE TEST ASSESSMENT TO BS EN 1364-1:1999 ON A 5M GYPWALL CLASSIC PARTITION OF 92 S 50 STUDS INCORPORATING A DOUBLE LAYER 15mm GYPROC SOUNDBLOC AND ISOVER APR 1200 IN THE

More information

Separating walls. Separating walls. Creating quiet, comfortable and safe living environments between adjoining homes.

Separating walls. Separating walls. Creating quiet, comfortable and safe living environments between adjoining homes. O4 Creating quiet, comfortable and safe living environments between adjoining homes. 51 Discover more on legislation throughout England, Wales and Scotland in this section, and how our systems can help

More information

Tiling. Tiling.

Tiling. Tiling. Tiles can be applied to drylined walls or the surface of lightweight partition systems to dado level or above. can be carried out in any type of building either in dry areas or in areas subject to intermittent

More information

Boards. Products - Boards.

Boards. Products - Boards. Products - Boards Boards Gyproc plasterboards are the ultimate lining solution for today's buildings, providing high levels of fire, sound, thermal, moisture and impact resistance to create modern internal

More information

SOUND INSULATION ASSESSMENT RANELAGH MULTI-DENOMINATIONAL SCHOOL, DUBLIN October 2014

SOUND INSULATION ASSESSMENT RANELAGH MULTI-DENOMINATIONAL SCHOOL, DUBLIN October 2014 SOUND INSULATION ASSESSMENT RANELAGH MULTI-DENOMINATIONAL SCHOOL, DUBLIN 6 22 October 2014 Project: Sound Insulation Assessment Ranelagh Multi-Denominational School, Dublin 6 7 Osborne Promenade Warrenpoint

More information

WORK, REST AND PLAY ISOVER MAKES IT POSSIBLE.

WORK, REST AND PLAY ISOVER MAKES IT POSSIBLE. Quiet Living WORK, REST AND PLAY ISOVER MAKES IT POSSIBLE. Isover s built in sound control. Simply building to the minimum sound standards outlined in the Building Regulations won t provide the comfort

More information

Report Number BTC 14020A

Report Number BTC 14020A Report Number BTC 14020A AN ACOUSTIC TEST REPORT COVERING A LABORATORY SOUND INSULATION TEST TO BS EN ISO 140-3:1995 ON A BRITISH GYPSUM GYPWALL QUIET SF PARTITION. TWO SETS OF TWO GANG CAVITY WALLBOXES

More information

Wall Linings. As well as complete dry lining solutions we also provide fast-drying parge coat to ensure airtightness,

Wall Linings. As well as complete dry lining solutions we also provide fast-drying parge coat to ensure airtightness, Wall Linings Our versatile range of wall lining systems makes it easy to produce a high-quality, high-performance finished wall regardless of the background. Whether your priority is acoustic control,

More information

A corridor ceiling system that combines acoustics, aesthetics and accessibility

A corridor ceiling system that combines acoustics, aesthetics and accessibility A corridor ceiling system that combines acoustics, aesthetics and accessibility All our systems are covered by SpecSure when using genuine British Gypsum and Saint-Gobain Isover products The provides the

More information

Knauf Wall Liner. Head Track. Brackets. Wall Lining Stud. Fixings. Knauf Plasterboard. Floor Track. 98 Wall Liner

Knauf Wall Liner. Head Track. Brackets. Wall Lining Stud. Fixings. Knauf Plasterboard. Floor Track. 98 Wall Liner The Knauf Wall Liner System is extremely versatile and can be specified for application on masonry backgrounds with moderate irregularities between 20mm and 125mm. It can accommodate any of the range of

More information

Separating walls. Separating walls. Creating quiet, comfortable and safe living environments between adjoining homes.

Separating walls. Separating walls. Creating quiet, comfortable and safe living environments between adjoining homes. O4 Creating quiet, comfortable and safe living environments between adjoining homes. 51 Discover more on legislation throughout England, Wales and Scotland in this section, and how our systems can help

More information

Sheathing Board Xtra protection, built in.

Sheathing Board Xtra protection, built in. Sheathing Board Xtra protection, built in. Introducing Glasroc X Sheathing Board Glasroc X is a high performance sheathing board which provides up to 6 months weather protection as certified by the British

More information

SoffitLine. Thermal lining system for semi-exposed soffits. SoffitLine.

SoffitLine. Thermal lining system for semi-exposed soffits. SoffitLine. Thermal lining system for semi-exposed soffits combines the aesthetic benefits of Glasroc MultiBoard with thermally efficient phenolic foam insulation. It can be directly fixed to the underside of semiexposed

More information

HOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES

HOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES HOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES 1 METAL OR TIMBER? When creating stud partitions, wall linings and suspended ceilings the traditional method of installation has been

More information

Gyproc Lay-in Grid Ceilings

Gyproc Lay-in Grid Ceilings are a lightweight ceiling system available in concealed or exposed grid options. They present an attractive pre-finished white ceiling and a range of decorative effects are possible by selecting the desired

More information

How glass or rock mineral wool works in a wall or floor cavity

How glass or rock mineral wool works in a wall or floor cavity Internal Walls Background to sound insulation Sound insulation Sound Insulation, otherwise known as sound reduction, is the prevention of sound being transmitted from one part of a building to another,

More information

Insulation - Products

Insulation - Products www.british-gypsum.com Isowool insulation The Isowool glass mineral wool insulation range from British Gypsum-Isover provides fire-safe thermal and acoustic insulation for masonry, steel frame and timber

More information

C07. S03. P02 P24 DriLyner basic, tl, mf, rf

C07. S03. P02 P24 DriLyner basic, tl, mf, rf ! This section includes updated information, added since it was first published in December 05. Last updated 9/0/08 C07. S0. P0 P DriLyner basic, tl, mf, rf Including C07. S0. P0 P0 Linings introduction

More information

Report Number BTC 16234A

Report Number BTC 16234A Report Number BTC 16234A An acoustic test report covering laboratory sound insulation testing to BS EN ISO 140-3:1995 on a British Gypsum GypWall Partition, incorporating Gypframe 92mm Studs (92S50) at

More information

Demountable suspended grid ceiling system

Demountable suspended grid ceiling system C06 Floors and ceilings CasoLine quicklock grid t5 CasoLine quicklock grid t5 Demountable suspended grid ceiling system All our systems are covered by SpecSure when using genuine Gyproc and Isover products

More information

Plaster skimming. Plaster skimming to plasterboard is a popular method of providing a smooth, seamless surface ready to receive decorative treatment

Plaster skimming. Plaster skimming to plasterboard is a popular method of providing a smooth, seamless surface ready to receive decorative treatment C08 Finishes to plasterboard is a popular method of providing a smooth, seamless surface ready to receive decorative treatment All our systems are covered by SpecSure when using genuine Gyproc and Isover

More information