CasoLine MF Concealed grid MF suspended ceiling system

Size: px
Start display at page:

Download "CasoLine MF Concealed grid MF suspended ceiling system"

Transcription

1 Concealed grid MF suspended ceiling system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated 0/09/0 0 Joseph Chamberlain College, Birmingham

2 α w Sound absorption is a suspended ceiling system suitable for most internal drylining applications. The fully concealed grid and ceiling lining can be used in conjunction with Gyproc plasterboards and Gyptone and Rigitone boards to create a seamless, monolithic appearance. R w db Airborne L nw db Impact l l l mins Key facts Monolithic appearance Suspension from concrete or timber floors and purlins Acoustic hangers provide option of resilient suspension GypWall RAPID and RAPID CasoLine db Plus MF A l Durable ceiling lining l Ventilation ducts and other services accommodated in plenum l Simple accommodation of access panels l Easy to create bulkheads and level change l Easily integrated with CasoLine GRID A Gypframe MF7 Primary Support Channel Gypframe MF Perimeter + Support Channel Gyproc Wafer Head Jack- Point Screws + + Gypframe MF Ceiling Section l Fully integrated access hatches Applications A wide range of residential and commercial applications. Sector Education High-rise multi-occupancy Healthcare Apartment buildings 0

3 L SPECSURE System components Gypframe metal products MF Ceiling Section Secondary section below Gypframe MF7 Primary Support Channel. MF Perimeter Channel Perimeter support for Gypframe MF Ceiling Section. MF7 Primary Support Channel Primary support section. MF Strap Hanger Suspension of ceiling grid. or GA Steel Angle Length 00mm Length 00mm Length 00mm Length m (coil) Length 900mm Fixing and finishing products Gyproc Profilex Access Panels For access to the plenum for maintenance purposes. Gyptone Access Panels To integrate with the Gyptone range of ceiling boards - LINE, QUATTRO, and 7. Gyproc Wafer Head Drywall Screws For Gypframe metal-to-metal fixing less than 0.mm thick ( I studs less than 0.mm thick). Gyproc Wafer Head Jack-Point Screws For fixing hanger to Gypframe MF7 Primary Support Channel, and for fixing Gypframe MF Ceiling Section to Gypframe MF7 Primary Support Channel. Gyproc Drywall Screws For fixing boards to Gypframe metal framing less than 0.mm thick ( I studs less than 0.mm thick). Gyproc Sealant Sealing air paths for optimum sound insulation. GAH Acoustic Hanger GAH Acoustic Hanger (supplied with washers). Length mm Length 70mm Gyproc jointing materials For seamless jointing. MF9 Connecting Clip Alternative method for fixing Gypframe MF Ceiling Section to Gypframe MF7 Primary Support Channel. MF Nut and Bolt Joining hanger to soffit cleat. MF Soffit Cleat Suspension point from structural soffit. Board products Gyproc WallBoard Thickness., mm Width 900mm Gyproc SoundBloc Thickness., mm Width 00mm Gyproc FireLine Thickness., mm Width 900mm Glasroc F MULTIBOARD Thickness, 0,.mm Width 00mm Glasroc F FIRECASE Thickness mm Width 00, 00mm Also available in DUPLEX grades where vapour control is required. Rigitone installation tools For installation and finishing of Rigitone boards. Rigitone Vario 0 For jointing of Rigitone boards. Thistle GypPrime For controlling suction on Rigitone board edges. Thistle Multi-Finish or Thistle Board Finish To provide a plaster skim finish. or Thistle Spray Finish Gypsum finish plaster for spray or hand application. Insulation products Isover APR 00 mm and 0mm, for improved acoustic and thermal performance. Isover Spacesaver Ready-Cut 00mm, for improved acoustic and thermal performance. Isover Frame Batt 0mm, for improved acoustic, thermal and fire performance. Isover Sound Deadening Floor Slab For providing sound deadening in timber-based intermediate separating floors. Stone mineral wool (by others) To achieve fire performance. T E F I I M E S Y S T E M W A R R A N T Y Always use genuine branded British Gypsum components to qualify for SpecSure lifetime warranty 0

4 L SPECSURE T F 0 E bgtechnical.enquiries@bpb.com System components (continued) Gyptone board products Gyptone QUATTRO Thickness.mm Gyptone QUATTRO Thickness.mm Length 00mm Length 00mm Width 00mm Width 900mm Rigitone board products Rigitone / Thickness.mm Length 99mm Width mm Rigitone 0/ Thickness.mm Length 00mm Width 9mm Gyptone QUATTRO Thickness.mm Length 00mm Width 00mm Gyptone QUATTRO 7 Thickness.mm Length 00mm Width 00mm Rigitone /0 Thickness.mm Length 00mm Width 00mm Rigitone -0/ Thickness.mm Length 90mm Width mm Gyptone LINE Thickness.mm Length 00mm Width 00mm Gyptone LINE 7 Curve Thickness.mm Length 00mm Width 900mm Rigitone --0 Thickness.mm Length 000mm Width 00mm Rigitone --0 SUPER Thickness.mm Length 90mm Width 00mm Gyptone BASE Curve Thickness.mm Length 00mm Width 900mm T E F I I M E S Y S T E M W A R R A N T Y Always use genuine branded British Gypsum components to qualify for SpecSure lifetime warranty 0

5 Installation overview Suspension from concrete soffit Gypframe MF Perimeter Channel is fixed to the wall at maximum 00mm centres, and Gypframe MF Soffit Cleats secured to the soffit at 00mm centres, using appropriate fixings. Gypframe MF Strap Hanger or Gypframe GA Steel Angles are pre-cut and secured to the soffit cleats with Gypframe MF Nut and Bolt. Gypframe MF7 Primary Support Channels are installed over the Gypframe MF Perimeter Channels. Fix hangers (two per fixing) to Gypframe MF7 Primary Support Channel using Gyproc Wafer Head Jack-Point Screws. Gypframe MF Ceiling Sections are run at right angles to the underside of primary channels to form the secondary grid. The ceiling sections are secured to the primary channels by using two Gyproc Wafer Head Jack-Point Screws. Alternatively, the Gypframe MF Ceiling Sections can be secured to the Gypframe MF7 Primary Support Channels using Gypframe MF9 Connecting Clips. Please refer to Ceiling lift in the Design section. Boards are fixed to the secondary grid to form single or multi-layer linings as specified. Suspension from timber joists The procedure is as for concrete except that soffit cleats are not required hangers are twice fixed directly to the side of the joists. Board fixings Board fixings for Gyproc and British Gypsum specialist boards should be at 0mm centres at board-ends, and at 0mm centres within the field of the board. Board fixings for Gyptone boards should be at 0mm centres across board-ends and through the field of the board. Board fixings for Rigitone boards should be at 0mm centres at perimeters and 0mm through the field of the board. A special procedure is used for fixing and jointing Rigitone boards. Detailed installation notes are given in the current British Gypsum Ceilings Installation Guide, available to download from For full installation details, refer to the British Gypsum SITE BOOK, available to download from For full installation details, refer to the British Gypsum SITE BOOK, available to download from 0

6 T F 0 E bgtechnical.enquiries@bpb.com Performance ( Fire resistance EN Refer to section - Basic principles of system design) Table fire protection to timber floor construction Solutions to satisfy the requirements of BS EN -: 000 L I F E T I M E SPECSURE S Y S T E M W A R R A N T Y Floor boarding of mm minimum t&g softwood or wood particle floor boarding. Solid timber joists x 9mm at 00mm centres. suspended ceiling fixed to joists. Ceiling linings as in table. Floor boarding of mm minimum t&g softwood or wood particle floor boarding. Solid timber joists x 9mm at 00mm centres. suspended ceiling fixed to joists. Ceiling linings as in table. Detail Board Ceiling MF MF7 System type lining support support reference thickness centres centres mm mm mm 0 minutes fire resistance EN FireLine x C minutes fire resistance EN Glasroc F MULTIBOARD x G00 EN Table fire protection to floor or roof cavity above suspended ceiling Solutions to satisfy the requirements of BS EN -: 999 L I F E T I M E SPECSURE S Y S T E M W A R R A N T Y suspended ceiling fixed to structure. mm stone mineral wool slabs (00kg/m ) laid over Gypframe MF Ceiling Section. Ceiling linings as in table. Detail Board Ceiling MF MF7 System type lining support support reference thickness centres centres mm mm mm 0 minutes fire resistance EN FireLine x C00 0 minutes fire resistance EN Glasroc F FIRECASE x 0 00 G000 The requirement for providing cavity barriers in the same plane as fire-resistant walls may not apply to cavities in floors and roofs if the ceiling beneath the floor or roof cavity provides a minimum of a full 0 minutes fire resistance (0 mins. integrity : 0 mins. insulation) in addition to satisfying other requirements. Refer to section 0 Cavity fire barriers. NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. NBS work section K0 - Plasterboard drylinings / partitions / ceilings 07

7 Performance ( BS Refer to section - Basic principles of system design) Table fire protection to timber floor construction Solutions to satisfy the requirements of BS 7: Part : 97 L I F E T I M E SPECSURE S Y S T E M W A R R A N T Y Floor boarding of mm minimum t&g softwood or wood particle floor boarding. Solid timber joists. x 9mm at 00mm centres. suspended ceiling fixed to joists. Ceiling linings as in table. Floor boarding of mm minimum t&g softwood or wood particle floor boarding. Solid timber joists x 9mm at 00mm centres. suspended ceiling fixed to joists. Ceiling linings as in table. Floor boarding of mm minimum t&g softwood or wood particle floor boarding. Solid timber joists x 9mm at 00mm centres. suspended ceiling fixed to joists. Ceiling linings as in table. Detail Board Ceiling Approx. MF MF7 System type lining weight support support reference thickness centres centres mm kg/m mm mm 0 minutes fire resistance BS FireLine x C000 WallBoard x C000 0 minutes fire resistance BS FireLine x C minutes fire resistance BS FireLine x C000 0 minutes fire resistance BS Glasroc F MULTIBOARD x G00 BS Table fire protection to floor or roof cavity above suspended ceiling Solutions to satisfy the requirements of BS 7: Part : 97 L I F E T I M E SPECSURE S Y S T E M W A R R A N T Y suspended ceiling fixed to structure. Normal fixing centres for Gypframe MFs and MF7s (0mm and 00mm respectively). Insulation laid over Gypframe MF Ceiling Section. 00mm Isover General Purpose Roll laid over Gypframe MF Ceiling Section. Ceiling linings as in table. suspended ceiling fixed to structure. Normal fixing centres for Gypframe MFs and MF7s (0mm and 00mm respectively). 0mm stone mineral wool slab kg/m laid over Gypframe MF Ceiling Section. Ceiling linings as in table. Detail Board Ceiling MF MF7 System type lining support support reference thickness centres centres mm mm mm 0 minutes fire resistance BS WallBoard x C00 0 minutes fire resistance BS FireLine x 0 00 C00 The requirement for providing cavity barriers in the same plane as fire-resistant walls may not apply to cavities in floors and roofs if the ceiling beneath the floor or roof cavity provides a minimum of a full 0 minutes fire resistance (0 mins. integrity : 0 mins. insulation) in addition to satisfying other requirements. Refer to section 0 Cavity fire barriers. NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. NBS work section K0 - Plasterboard drylinings / partitions / ceilings 0

8 T F 0 E bgtechnical.enquiries@bpb.com BS Table fire protection to steel beams supporting concrete floors Solutions to satisfy the requirements of BS 7: Part : 97 L I F E T I M E SPECSURE S Y S T E M W A R R A N T Y ceiling suspended beneath steel beams supporting a concrete floor. Ceiling linings as in table. ceiling suspended beneath steel beams supporting a concrete floor. Ceiling linings as in table. Detail Board Ceiling Approx. MF MF7 System type lining weight support support reference thickness centres centres mm kg/m mm mm 0 minutes fire resistance BS WallBoard x C000 0 minutes fire resistance BS FireLine x C000 Glasroc F MULTIBOARD x G000 0 minutes fire resistance BS Glasroc F MULTIBOARD x G000 FireLine x C000 Concrete floors as described in BS 7: Part. The steel beams subjected to test had a section factor A/V (Hp/A) of 0m - calculated on the basis of three sided profiled exposure. The suspended ceiling will also provide adequate protection to steel beams with a lower section factor. NBS work section K0 - Plasterboard drylinings / partitions / ceilings 09

9 Performance ( Refer to section - Basic principles of system design) Sound insulation Table upgrading the sound insulation of concrete floors L I F E T I M E SPECSURE S Y S T E M W A R R A N T Y ceiling suspended beneath basic floor to give 0mm cavity. Ceiling linings as in table. ceiling suspended beneath basic floor to give 0mm cavity. Ceiling linings as in table. ceiling suspended beneath basic floor to give 0mm cavity, with 00mm Isover Spacesaver Ready-Cut in cavity. Ceiling linings as in table. ceiling suspended beneath basic floor to give 0mm cavity, with 00mm Isover Spacesaver Ready-Cut in cavity. Ceiling linings as in table. Detail Board Ceiling Approx. Sound insulation System type lining weight Airborne Impact reference thickness R w (R w + Ctr) L nw mm kg/m db db WallBoard x. 0 (0) C000 WallBoard x. () C0007 SoundBloc x. () 0 C000 SoundBloc x. () 7 C0009 Basic floor construction is lightweight concrete joist floor with insulated concrete infill panel (surface density of infill is 90kg/m ) and total depth 0mm. Sound insulation is R w db (airborne) and L nw 9 db (impact). NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. NBS work section K0 - Plasterboard drylinings / partitions / ceilings 0

10 T F 0 E bgtechnical.enquiries@bpb.com EN BS Table 7 upgrading the fire resistance and sound insulation of timber floors Solutions to satisfy the requirements of BS EN -: 000 (where applicable) and BS 7: Part : 97 L I F E T I M E SPECSURE S Y S T E M W A R R A N T Y ceiling suspended beneath basic floor (ceiling removed) to give 77mm cavity. 00mm Isover Spacesaver Ready-Cut laid on ceiling boards. Ceiling linings as in table. ceiling suspended beneath basic floor (ceiling removed) with a layer of Gyproc Plank fixed to the underside of the chipboard to give a mm cavity. 00mm Isover Spacesaver Ready-Cut laid on ceiling boards. Ceiling linings as in table. ceiling suspended beneath basic floor (ceiling removed) using Gypframe Acoustic Hangers to give 77mm cavity. 00mm Isover Spacesaver Ready-Cut laid on ceiling boards. Ceiling linings as in table. New floating floor laid over joists. ceiling suspended beneath 9mm x mm timber joists at 00mm centres to give 77mm cavity. 00mm Isover Spacesaver Ready-Cut laid on ceiling boards. Ceiling linings as in table. ceiling suspended beneath GypFloor SILENT using Gypframe Acoustic Hangers to give 77mm cavity. 00mm Isover Spacesaver Ready-Cut laid on ceiling boards. Ceiling linings as in table. Detail Board Ceiling Approx. Floor Sound insulation System type lining weight depth Airborne Impact reference thickness R w (R w + Ctr) L nw mm kg/m mm db db 0 minutes fire resistance BS SoundBloc x C0007 SoundBloc x. 0 () 7 C0009 SoundBloc x. 0 () C00 SoundBloc x. 7 () 0 C00 0 minutes fire resistance EN BS SoundBloc x C00 FireLine x. 0 () C00 SoundBloc x 7 () C00 SoundBloc x 7 () 0 C00 SoundBloc x 7 () C00 90 minutes fire resistance BS FireLine x 9 C000 FireLine x () C00 Basic floor construction is mm x 9mm timber joists at 00mm centres with mm t&g wood chipboard flooring. mm t&g wood chipboard spot bonded to Gyproc Plank on Isover Sound Deadening Floor Slab laid on overlining of mm plywood. NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. NBS work section K0 - Plasterboard drylinings / partitions / ceilings

11 Table Sound absorption data for Gyptone boards - tested on a 00mm plenum QUATTRO Gyptone QUATTRO 0 00 k k k α w AC NRC C 0.70 C0A09 QUATTRO Gyptone QUATTRO Gyptone QUATTRO plus 0mm Isover APR k k k α w AC NRC C C 0.7 C0A0 C0A07 QUATTRO C0A0 C0A0 Gyptone QUATTRO Gyptone QUATTRO plus 00mm Isover Spacesaver Ready-Cut 0 00 k k k α w AC NRC (L) D (L) D 0. QUATTRO C0A0 C0A07 Gyptone QUATTRO 7 Gyptone QUATTRO 7 plus 0mm Isover APR k k k α w AC NRC (L) D 0. (L) D 0. AC Absorption Class. NRC Noise Reduction Coefficient. NB For further information on sound absorption performance of Gyptone boards, refer to British Gypsum Ceiling Products Acoustic Performance Data publication, available to download from NB All products have been tested to BS EN 0 and ISO. The single figure rating practical sound absorption coefficient α w is calculated in accordance with EN ISO. Suffix letters indicate where performance is limited at either low, medium or high frequencies.

12 T F 0 E bgtechnical.enquiries@bpb.com Table (continued) Sound absorption data for Gyptone boards - tested on a 00mm plenum LINE C0A00 C0A00 Gyptone LINE Gyptone LINE plus 00mm Isover Spacesaver Ready-Cut 0 00 k k k α w AC NRC (L) D (L) D 0. LINE 7 Curve C0A0 C0A09 Gyptone LINE 7 Curve Gyptone LINE 7 Curve plus 00mm Isover Spacesaver Ready-Cut 0 00 k k k α w AC NRC (L) D (L) D 0. AC Absorption Class. NRC Noise Reduction Coefficient. NB For further information on sound absorption performance of Gyptone boards, refer to British Gypsum Ceiling Products Acoustic Performance Data publication, available to download from NB All products have been tested to BS EN 0 and ISO. The single figure rating practical sound absorption coefficient α w is calculated in accordance with EN ISO. Suffix letters indicate where performance is limited at either low, medium or high frequencies.

13 Table 9 Sound absorption data for Rigitone boards / Rigitone / (plenum depth 0mm) Rigitone / (plenum depth 00mm) Rigitone / (plenum depth 00mm plus 0mm Isover Frame Batt ) 0 00 k k k α w AC NRC (M) D 0. C0A0 C0A07 C0A (LM) D (LM) C 0. 0/ Rigitone 0/ (plenum depth 0mm) Rigitone 0/ (plenum depth 00mm) Rigitone 0/ (plenum depth 00mm plus 0mm Isover Frame Batt ) 0 00 k k k α w AC NRC (M) D C0A0 C0A09 C0A (LM) D (LM) C 0. /0 Rigitone /0 (plenum depth 0mm) Rigitone /0 (plenum depth 00mm) Rigitone /0 (plenum depth 00mm plus 0mm Isover Frame Batt ) 0 00 k k k α w AC NRC (M) D 0. C0A00 C0A0 C0A (LM) D (LM) C 0. AC Absorption Class. NRC Noise Reduction Coefficient. NB For further information on sound absorption performance of Gyptone boards, refer to British Gypsum Ceiling Products Acoustic Performance Data publication, available to download from NB All products have been tested to BS EN 0 and ISO. The single figure rating practical sound absorption coefficient α w is calculated in accordance with EN ISO. Suffix letters indicate where performance is limited at either low, medium or high frequencies.

14 T F 0 E bgtechnical.enquiries@bpb.com Table 9 (continued) Sound absorption data for Rigitone boards -0/ Rigitone -0/ (plenum depth 0mm) Rigitone -0/ (plenum depth 00mm) Rigitone -0/ (plenum depth 00mm plus 0mm Isover Frame Batt ) 0 00 k k k α w AC NRC (M) D 0. C0A0 C0A0 C0A (LM) D (LM) C Rigitone --0 (plenum depth 0mm) Rigitone --0 (plenum depth 00mm) Rigitone --0 (plenum depth 00mm plus 0mm Isover Frame Batt ) 0 00 k k k α w AC NRC (LM) E 0. C0A0 C0A07 C0A (LM) D (LM) D SUPER Rigitone --0 SUPER (plenum depth 0mm) Rigitone --0 SUPER (plenum depth 00mm) Rigitone --0 SUPER (plenum depth 00mm plus 0mm Isover Frame Batt ) 0 00 k k k α w AC NRC (LM) D 0. C0A0 C0A09 C0A (LM) D (LM) D 0.70 AC Absorption Class. NRC Noise Reduction Coefficient. NB For further information on sound absorption performance of Gyptone boards, refer to British Gypsum Ceiling Products Acoustic Performance Data publication, available to download from NB All products have been tested to BS EN 0 and ISO. The single figure rating practical sound absorption coefficient α w is calculated in accordance with EN ISO. Suffix letters indicate where performance is limited at either low, medium or high frequencies.

15 Design Cavity barriers Where cavity barriers are required, these can be formed using Gyproc FireLine or Glasroc F MULTIBOARD screw-fixed to a simple metal or timber frame. The framing should be fixed to the structure to avoid undue loading of the ceiling suspension grid or, alternatively, additional hangers should be incorporated to support the ceiling alongside the cavity barrier. Refer to section 0 Cavity fire barriers. Relative humidity ceilings lined with Gyproc, Gyptone, Rigitone or British Gypsum specialist boards are suitable for use under normal occupancy conditions. Buildings in which they are used should be dry, glazed and enclosed, with environmental conditions of no greater than 70% RH at 0 C to 0 C. For high humidity / high moisture conditions use Gyproc plasterboard MR variants or Glasroc F MULTIBOARD. Vapour control For areas other than where perforated Gyptone or Rigitone boards are used, a face layer of DUPLEX grade plasterboard or two coats of Gyproc Drywall Sealer applied to the face of the lining will provide water vapour control. Acoustic performance Gyptone and Rigitone boards are perforated and designed to provide sound absorption when used in conjunction with an airspace behind the ceiling. Increased levels of sound absorption can be achieved by including insulation over the back of the ceiling. Where sound insulation room-to-room is required, sound attenuation (D ncw ) of 9 db can be achieved by the inclusion of 00mm Isover Spacesaver Ready-Cut over the back of the ceiling. Alternatively, other design considerations should be adopted such as extending adjoining partitions into the plenum void or installing a plenum barrier. Thermal performance Isover insulation can be laid over the suspension grid to provide the required standard of thermal insulation. Contact the British Gypsum Drywall Academy for further guidance. Suspension - Gyproc, British Gypsum specialist and Gyptone board linings Fixing points for suspending the metal grid are required at 00mm centres in each direction. Suitable fixing devices should be employed when fixing to the structure. The ceiling grid can be suspended from a concrete soffit using Gypframe MF Soffit Cleats and Gypframe MF Strap Hanger, or alternatively, Gypframe GA Steel Angle. The latter provides a more robust suspension support, which restricts any flexing of the lining when pressure is applied from below. Gypframe GA Steel Angle is thus the preferred suspension option when a plaster finish is specified to Gyproc boards. If Gypframe GA Steel Angle is used, it is recommended that it is fixed to the soffit via Gypframe MF Soffit Cleats. If fixing Gypframe GA Steel Angle direct to the soffit, the angle is cut and bent to fit. However, this will reduce the maximum loads that the grid is capable of supporting by %. Furthermore, fixing Gypframe GA Steel Angles direct is not suitable if the ceiling is likely to deflect due to varying pressures and is not suitable for fixing to a sloping substrate. Gypframe Acoustic Hangers can be used to suspend the grid from timber joists to maximise the degree of acoustic isolation (see Construction details 7). In a comparative test a db improvement in airborne sound insulation and a db improvement in impact sound insulation were achieved. See Table 7, Construction details and, relating to double layer Gyproc SoundBloc linings. With concrete floors the high mass of the construction means that high levels of acoustic performance can be achieved when the ceiling is suspended by conventional means, i.e. Gypframe MF Strap Hangers or Gypframe GA Steel Angle. Suspension - Rigitone board linings Gypframe MF7 Primary Support Channels are fixed at 000mm centres. Fixing points to the structure for the Gypframe MF7 Primary Support Channels are required at 900mm centres. In addition to this, the Gypframe MF Ceiling Section should be installed at nominal 0mm centres. Ceiling lift Changes to Building Regulations Approved Document L, airtightness requirements within dwellings, can lead to greater changes in air pressure when a door is opened. The ceiling is normally the lightest fixed element in the room, and therefore most likely to be affected by this change in pressure. This can cause the ceiling to lift, which may create a noise. Whilst this noise can be annoying to the occupier, it has no detrimental effect on the performance of the ceiling. The designer should consider incorporating a pressure release system to minimise the risk of ceiling lift. Where sufficient pressure relief cannot be designed in, it is recommended that the Gypframe MF Ceiling Section and the Gypframe MF7 Primary Support Channel should be screw-fixed together using two Gyproc Wafer Head Jack-Point Screws at each intersection, particularly where non-perforated board linings are specified. Partition to suspended ceiling junction In situations where a GypWall metal stud partition passes through a ceiling, which is to both sides of the partition and appropriately fixed to both this partition and perimeter partitions / walls, consideration can be given to the lateral restraint provided by the ceiling when developing the partition specification. The relevant maximum height is the greater of the floor to ceiling or ceiling to structural soffit height. Care should be taken during installation of tall partitions so as to not adversely affect their performance. Contact the British Gypsum Drywall Academy for further guidance. Where a GypWall metal stud partition is fixed to the framework of a ceiling, in accordance with British Gypsum s installation instructions, the permissible maximum height is equal to that of where it is fixed direct to a structural soffit of the same height. Please refer to section - Basic principles of system design for general guidance

16 T F 0 E bgtechnical.enquiries@bpb.com Imposed loads Tables, and provide loading data for the suspension grid for Gyproc, British Gypsum specialist, Gyptone and Rigitone boards respectively. Maximum loads will be reduced by % when Gypframe GA Steel Angle is fixed directly to the soffit (modified loads are shown in brackets). Table 0 Maximum recommended loads on with Gyproc or British Gypsum specialist board linings Maximum load including Suspension MF7 weight of board and any point channel insulation centres centres MF at 0mm centres kg/m (modified load) mm mm Services The plenum can be used to route all service requirements including ducting, pipework, electrical cables and conduit. Where light fittings, access panels and similar components are incorporated as part of the design requirements, consideration must be given to maintaining the integrity of the ceiling to meet fire resistance and sound insulation requirements. Fixtures Fixings to the system should always be made into the metal grid or to supplementary framing. Some adjustment of the primary grid may be required to support particularly heavy loads, see Tables, and. Where loads outside this range are anticipated, independent suspension should be provided from the structure. 0 () (0) () () Gypframe MF Ceiling Section. Gypframe MF7 Primary Support Channel. Table Maximum recommended loads on with Gyptone board linings Maximum load including Suspension MF7 weight of board and any point channel insulation centres centres MF at 00mm centres kg/m (modified load) mm mm Control joints Gyproc Control Joints may be required in the ceiling to relieve stresses induced by expansion and contraction of the structure. It is recommended that they coincide with movement joints within the surrounding structure. Rigitone expansion joints Rigitone boards should be cut 0mm short of the perimeter wall and should not be fixed to the perimeter channel, see Construction details -. Board finish Additional care and attention should be exercised when jointing Rigitone boards so as not to fill the perforations and impair the acoustic performance of the finished ceiling. Refer to section Finishing systems and decorative effects. () () (9) Gypframe MF Ceiling Section. Gypframe MF7 Primary Support Channel. Table Maximum recommended loads on with Rigitone board linings Maximum load including Suspension MF7 weight of board and any point channel insulation centres centres MF at 0mm centres kg/m (modified load) mm mm 0 () Gypframe MF Ceiling Section. Gypframe MF7 Primary Support Channel. Please refer to section - Basic principles of system design for general guidance 7

17 Construction details Perimeter parallel to Gypframe MF Ceiling Section - screw-fixed Perimeter perpendicular to Gypframe MF Ceiling Section - screw-fixed Bulkhead - screw-fixed Change of level - screw-fixed Max. 0mm 7 Max. 00mm Max. 0mm Max. 00mm Max. 0mm 7 Gyproc plasterboard or British Gypsum specialist board Gypframe MF Ceiling Section Gypframe MF Perimeter Channel Gypframe MF7 Primary Support Channel Gypframe MF Strap Hanger or Gypframe GA Steel Angle Gyproc Wafer Head Jack-Point Screw Gypframe MF Nut and Bolt Gypframe MF Soffit Cleat

18 T F 0 E bgtechnical.enquiries@bpb.com Reflected ceiling plan - single layer Reflected ceiling plan - double layer Gyproc plasterboard or British Gypsum specialist board Gypframe MF Ceiling Section Gypframe MF Perimeter Channel Gypframe MF7 Primary Support Channel Gypframe MF Strap Hanger or Gypframe GA Steel Angle 9

19 7 Suspension from timber joist using Gypframe Acoustic Hangers 0 9 mm 7 Gyproc Profilex Access Panel installation 7 Gyproc plasterboard or British Gypsum specialist board Gypframe MF Ceiling Section Gypframe MF Perimeter Channel Gypframe MF7 Primary Support Channel Gypframe MF Strap Hanger or Gypframe GA Steel Angle Gyproc Wafer Head Jack-Point Screw Gypframe MF Nut and Bolt Gypframe MF Soffit Cleat 9 Gypframe Acoustic Hanger fixed with two Gyproc Drywall Timber Screws 0 M bolt and locking nut (by others) Timber joist floor Isover insulation Gypframe GA Steel Angle Gyproc Profilex Access Panel 0

20 T F 0 E bgtechnical.enquiries@bpb.com 9 Perimeter parallel to Gypframe MF Ceiling Section - Gyptone 0 Perimeter perpendicular to Gypframe MF Ceiling Section - Gyptone Reflected ceiling plan - Gyptone Gyptone boards Gypframe MF Ceiling Section Gypframe MF Perimeter Channel Gypframe MF7 Primary Support Channel Gypframe MF Strap Hanger or Gypframe GA Steel Angle Gypframe MF9 Connecting Clip

21 Perimeter parallel to Gypframe MF Ceiling Section - Rigitone Max. 0mm Perimeter perpendicular to Gypframe MF Ceiling Section - Rigitone Max. 0mm 7 7 Reflected ceiling plan - Rigitone Rigitone boards Gypframe MF Ceiling Section Gypframe MF Perimeter Channel Gypframe MF7 Primary Support Channel 7 Gypframe MF Strap Hanger or Gypframe GA Steel Angle Gypframe MF9 Connecting Clip Rigitone Vario 0 filler NB A special procedure is used for fixing and jointing Rigitone boards. Detailed installation notes are given in the current British Gypsum Ceilings Installation Guide, available to download from

22 T F 0 E bgtechnical.enquiries@bpb.com

CasoLine MF Concealed grid MF suspended ceiling system

CasoLine MF Concealed grid MF suspended ceiling system Concealed grid MF suspended ceiling system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated

More information

C06. S02. P02 P22 CasoLine mf

C06. S02. P02 P22 CasoLine mf ! This section includes updated information, added since it was first published in December 0. Last updated 6//06 C06. S0. P0 P CasoLine mf Including C06. S0. P0 P08 Floors and ceilings introduction C06

More information

CO9. Sound absorbing solutions C09

CO9. Sound absorbing solutions C09 ! This section includes updated information, added since it was first published in December 05. Section Last updated Introduction /0/06 CasoLine mf /05/07 CasoLine curve /05/07 GypLyner universal /05/07

More information

Loadbearing timber joist floors

Loadbearing timber joist floors C06 Floors and ceilings Internal and separating floor systems Timber joists are widely used within internal floor and separating floor construction, both in residential and coercial applications. Our range

More information

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner UNIVERSAL Metal framed wall lining system Metal framed wall lining system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated 0/0/00 Cadbury

More information

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner UNIVERSAL Metal framed wall lining system Metal framed wall lining system Pizza Express, York 30 Metal framed wall lining system wall lining system is a cost-effective, virtually independent metal frame drylining. It is a general purpose system

More information

Issue date: 1st May Key changes since original publication (July 2005):

Issue date: 1st May Key changes since original publication (July 2005): Issue date: st May 008 Key changes since original publication (July 00): May 008 Pages 0 & tables a & b - spec A06A08 Sound Insulation changed from 0 to 9 Rw db rating. September 00 Pages 66 & 6 tables

More information

Quantity take-off details

Quantity take-off details Quantitiy take-off details 6 Quantity take-off details Quantities Choose system specification / height or area as required, as given in the left hand column. Read across the columns to determine the quantity

More information

Tiling Tiling

Tiling Tiling 416 Tiles can be applied to drylined walls or the surface of lightweight partition systems to dado level or above. can be carried out in any type of building either in dry areas or in areas subject to

More information

C05. S03. P02 P08 FireWall

C05. S03. P02 P08 FireWall ! This section includes updated information, added since it was first published in December 2015. Last updated 16/12/2016 C05. S03. P02 P08 Including C05. S01. P02 Specialist partitions introduction C05

More information

The extra strong, extra durable, sound resistant system that you can direct fix to

The extra strong, extra durable, sound resistant system that you can direct fix to C0 Partitions The extra strong, extra durable, sound resistant system that you can direct fix to All our systems are covered by SpecSure when using genuine Gyproc and Isover products gyproc.ie Utilising

More information

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products. GypLyner GypLyner Metal framed wall lining system All our systems are covered by SpecSure when using genuine Gyproc and Isover products Linings GypLyner GypLyner is a cost-effective, virtually independent

More information

C05. S02. P02 P30 ShaftWall

C05. S02. P02 P30 ShaftWall ! This section includes updated information, added since it was first published in December 0. Last updated 0//0 C0. S0. P0 P0 Including C0. S0. P0 Specialist partitions introduction C0 Specialist partitions

More information

Staggered stud acoustic partition system

Staggered stud acoustic partition system GypWall STAGGERED GypWall STAGGERED Staggered stud acoustic partition system GypWall STAGGERED is a nonloadbearing metal stud partition which provides very high levels of sound insulation. In public and

More information

ShaftWall. Shaft and duct encasement system. ShaftWall.

ShaftWall. Shaft and duct encasement system. ShaftWall. ShaftWall ShaftWall Shaft and duct encasement system ShaftWall provides a lightweight, non-loadbearing fire-resistant structure to protect elements within the service cores of modern fast-track developments.

More information

Staggered stud acoustic partition system

Staggered stud acoustic partition system C0 Partitions Staggered stud acoustic partition system All our systems are covered by SpecSure when using genuine Gyproc and Isover products is a non-loadbearing stud partition incorporating a single framework

More information

GypLyner (walls) Metal framed wall lining system. GypLyner.

GypLyner (walls) Metal framed wall lining system. GypLyner. GypLyner GypLyner (walls) Metal framed wall lining system GypLyner is a cost-effective, virtually independent metal frame drylining system for lining walls. General purpose and suitable for all internal

More information

Knauf MF Suspended Ceilings

Knauf MF Suspended Ceilings Suspended Ceilings The Suspended Ceiling system is versatile and easy to install. Deep voids are easily created to hide services and the ceiling can be used to provide fire protection. Metal Components

More information

Boards. Products - Boards.

Boards. Products - Boards. Products - Boards Boards Gyproc plasterboards are the ultimate lining solution for today's buildings, providing high levels of fire, sound, thermal, moisture and impact resistance to create modern internal

More information

Tiling Tiling Finishes C08

Tiling Tiling Finishes C08 C08 Finishes In rooms subject to high or intermittent moisture conditions, the range of boards available for tiling offers flexibility of design and peace of mind when installed in both wall linings, lightweight

More information

CO3. Steel encasements C03. Introduction - FireCase 01/12/2017 GypLyner encase 11/05/2017. Introduction Steel encasements

CO3. Steel encasements C03. Introduction - FireCase 01/12/2017 GypLyner encase 11/05/2017. Introduction Steel encasements ! This section includes updated information, added since it was first published in ecember 05. Section Last updated Introduction - FireCase 0//07 GypLyner encase /05/07 Introduction Steel encasements C03

More information

Selecting partitions

Selecting partitions email: bgtechnical.enquiries@bpb.com www.british-gypsum.com/health Introduction 6 Performance matrix 8 Worked examples 0 your partition type Solutions up to R w db This section will guide you through the

More information

ting Join Jointing Finishes C08

ting Join Jointing Finishes C08 C08 Finishes Gyproc jointing materials produce durable joint reinforcement and a smooth, continuous, crack-resistant surface ready for priming and final decoration All our systems are covered by SpecSure

More information

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250 FIRE PROTECTION GTEC Shaftwall range uses a specially designed system to protect voids and shafts in buildings. It resists pressure changes and enables installation from one side of the shaft only. GTEC

More information

WORK, REST AND PLAY ISOVER MAKES IT POSSIBLE.

WORK, REST AND PLAY ISOVER MAKES IT POSSIBLE. Quiet Living WORK, REST AND PLAY ISOVER MAKES IT POSSIBLE. Isover s built in sound control. Simply building to the minimum sound standards outlined in the Building Regulations won t provide the comfort

More information

F L O O R S A N D C E I L I N G S

F L O O R S A N D C E I L I N G S INTRODUCTION Contents Performance Tables 163 Lafarge plasterboard direct to timber ceilings 179 Cormet Dryliner to timber joist floors 187 Cormet Dryliner to concrete floors 193 Cormet Suspended Metal

More information

Plasterboard accessories - Products

Plasterboard accessories - Products www.british-gypsum.com Gyproc plasterboard accessories The Gyproc range of accessories includes everything you need to finish plasterboard linings and partitions ready for decoration. Every stage is catered

More information

Tiling. Capital Gate Hotel, Abu Dhabi - UAE

Tiling.  Capital Gate Hotel, Abu Dhabi - UAE 166 202 Capital Gate Hotel, Abu Dhabi - UAE Tiles can be applied to drylined walls or to the surface of lightweight partition systems. can be carried out in any type of building, either in dry areas or

More information

SOUND SOLUTIONS TO MEET THE APPROVED DOCUMENT E (2003 EDITION) August 2008

SOUND SOLUTIONS TO MEET THE APPROVED DOCUMENT E (2003 EDITION) August 2008 SOUND SOLUTIONS TO MEET THE APPROVED DOCUMENT E (2003 EDITION) August 2008 PART E AT A GLANCE The New Approved Document E, (2003 Edition) was implemented on 1st July 2003. This applies to houses, flats,

More information

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague, Part E Pack Dear Colleague, This is the first 2017 update to the Part E Robust Details Handbook. In this update pack, we have focussed on clarifying the situation on incorporating underfloor heating (UFH)

More information

June Residential Refurbishment Separating walls

June Residential Refurbishment Separating walls June 2010 Residential Refurbishment 3.6.1 Separating walls Residential refurbishment 3.0 Residential Refurbishment Separating Walls Contents Introduction find online page Solution optimiser and pathfinder

More information

SOUND INSULATION TESTING IN DWELLINGS

SOUND INSULATION TESTING IN DWELLINGS SOUND INSULATION TESTING IN DWELLINGS Chris Dilworth, AWN Consulting This Presentation Discusses the standards by which we judge sound insulation performance. Presents the results of sound insulation tests

More information

Benefits.

Benefits. PARTITIONING Systems Stud & Track An economical friction-fit system to assemble frames for strong, compact, lightweight non load-bearing partitions. The metal stud partitioning is ideal for use in domestic

More information

Product Information Sheet

Product Information Sheet Product Information Sheet Product Name ISOVER Metac - high performance insulation Metac G3 Touch is a high performance low lambda mineral wool insulation roll with both excellent thermal and acoustic properties.

More information

The Revolutionary New Plasterboard TIMBER FRAME GUIDE

The Revolutionary New Plasterboard TIMBER FRAME GUIDE The Revolutionary New Plasterboard TIMBER FRAME GUIDE 2 HABITO BOARD is a stronger plasterboard that provides enhanced sound insulation, extra durability and for the first time, direct fixing capability.

More information

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red Plant Areas External plant must meet the following noise suppression requirement as adopted by the Landlord: 1. Air handling units 45db measured at 3metres from source. 2. Heat rejection plant 45db measured

More information

Specialists in Acoustic Flooring and House to Flat Conversions

Specialists in Acoustic Flooring and House to Flat Conversions Sound Solution Consultants Ltd Po Box 755 Capel St Mary Ipswich Suffolk IP9 2WF Tel No: 0845 5212096 Fax No: 0845 5212097 Email: mpconsultservice@aol.com Specialists in Acoustic Flooring and House to Flat

More information

RMF Intercell. NBS Specification 2013 K41

RMF Intercell. NBS Specification 2013 K41 RMF Intercell NBS Specification 2013 K41 InterfaceFLOR BV. K41 Specification 40mm, 60mm, 80mm, 90mm and 110mm K41 Raised access floors To be read with Preliminaries/ General conditions. TYPES OF RAISED

More information

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Xtratherm Thin-R Thermal Liner (XT/TL Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 4 Xtratherm Thin-R Thermal Liner (XT/TL Grade) PRODUCT DESCRIPTION: This Detail Sheet relates to Xtratherm Thin-R Thermal Liner, as defined in NSAI Agrément Certificate

More information

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD SECTION 09250 GYPSUM BOARD PART 1GENERAL 1.1 SUMMARY A. Related Documents: General and Supplementary Conditions of the Contract, Division 1 - General Requirements, and Drawings are collectively applicable

More information

Plaster systems. Plaster systems.

Plaster systems. Plaster systems. Plaster systems Plaster systems Gyproc plasters have been formulated to suit a wide variety of background types including concrete, brick, blockwork, sand / cement, Gyproc Plasterboards and expanded metal

More information

SECTION E Ceiling Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications. Floor/Ceiling Systems

SECTION E Ceiling Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications. Floor/Ceiling Systems SECTION E Ceiling Systems. Contents. SUBJECT Introduction Design Considerations Installation Components PAGE E2 E2 E4 E4 System Specifications Floor/Ceiling Systems Roof/Ceiling Systems E6 E12 Floor or

More information

Product Information Sheet

Product Information Sheet Product Information Sheet Product Name ISOVER Spacesaver Roll A mineral wool roll for domestic attic floors. Rolls pre-perforated to 3 x 386cm and 2 x 580cm widths to fit between common joist spacings.

More information

CI/SfB. November Design Guide Concrete block masonry

CI/SfB. November Design Guide Concrete block masonry CI/SfB November 1997 Ff Design Guide Concrete block masonry Design Guide concrete block masonry This Topblock Design Guide contains detailed information on the design and performance of constructions using

More information

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW.

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW. AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW www.stromatech.com AIR BARRIER DESIGN PRINCIPLES Building Regulations Approved Document Parts L1A & L2A currently requires that new buildings have to achieve a

More information

HOW TO: BOARD ROOMS WITH HIGH HUMIDITY AND CONDENSATION GTEC MOISTURE AND VAPOUR BOARD WITH PLASTERBOARD

HOW TO: BOARD ROOMS WITH HIGH HUMIDITY AND CONDENSATION GTEC MOISTURE AND VAPOUR BOARD WITH PLASTERBOARD HOW TO: BOARD ROOMS WITH HIGH HUMIDITY AND CONDENSATION WITH PLASTERBOARD GTEC MOISTURE AND VAPOUR BOARD 3 MOISTURE AND HUMIDITY Kitchens, utility rooms and cloak rooms are areas of high humidity, modern

More information

September Saddle Flooring Systems

September Saddle Flooring Systems September 2011 Saddle Flooring Systems Saddle Flooring Systems Saddle System Principles CMS Danskin Saddle Flooring Systems are dry floating floors which provide an easily levelled understructure for supporting

More information

V1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide

V1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide V1/0715/AI/TDO1 KORE Loft Insulated Flooring System Design Guide KORE Loft Insulated Flooring System Key Features Excellent thermal performance for the lifetime of the building Sheets tongue and grooved

More information

Gyptone edge D1 system Installation manual

Gyptone edge D1 system Installation manual Installation manual Design and technique Product description Gyptone edge D is a pre-painted, demountable suspended acoustic ceiling, mounted in a concealed grid system (T-). Gyptone ceilings can be used

More information

Plastering. Holiday Inn - Sultanate of Oman

Plastering.  Holiday Inn - Sultanate of Oman 1 208 Holiday Inn - Sultanate of Oman Gyproc GypFine Plasters provide the ultimate skimming solutions for today s high-end finish. They are formulated to suit a wide variety of backgrounds including plasterboard,

More information

icore HR outperforms other building boards in many important ways including the following:

icore HR outperforms other building boards in many important ways including the following: icore HR is a new and innovative system designed to provide high performance separating walls between units and apartments in high-rise commercial projects. icore HR system provides exceptional fire and

More information

ROCKFON SYSTEM T24 A/E

ROCKFON SYSTEM T24 A/E System description ROCKFON SYSTEM T24 A/E Versatile ceiling system Quick and easy to install Visible grid Easy integration with services and fittings Ceiling comprising Chicago Metallic T24 Click 2890

More information

HOW TO: INSULATE YOUR HOME AND UNDERSTAND U-VALUES GTEC THERMAL BOARD WITH PLASTERBOARD

HOW TO: INSULATE YOUR HOME AND UNDERSTAND U-VALUES GTEC THERMAL BOARD WITH PLASTERBOARD HOW TO: INSULATE YOUR HOME AND UNDERSTAND U-VALUES WITH PLASTERBOARD GTEC THERMAL BOARD 1 BUILDING INSULATION THE REGULATIONS Building regulations are in place to drive improvements in thermal efficiency,

More information

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

AND ACCESSORIES FOR DRYWALL CONSTRUCTION STEEL TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION Quality in your corner. THE STRENGTH WITHIN MONTREAL TORONTO CALGARY EDMONTON VANCOUVER STEEL TRIMS AND ACCESSORIES for Construction BAILEY HAS YOUR

More information

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD ASSEMBLIES SECTION 09 21 16 GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Metal stud wall and ceiling framing, 20 gauge. B. Metal channel suspended ceiling framing. C. Gypsum board. D. Gypsum sheathing.

More information

GypLyner universal. Internal wall insulation (IWI) installation guide

GypLyner universal. Internal wall insulation (IWI) installation guide GypLyner universal Internal wall insulation (IWI) installation guide i GypLyner universal Internal wall insulation Pre-Installation survey requirements It is important to note that the survey should be

More information

TILING SPECIFICATIONS

TILING SPECIFICATIONS TILING SPECIFICATIONS SPECIFICATION NUMBER: NR204-16 PREPARED BY: Mike Cubley PREPARED FOR: Porcelain Plus ATTENTION: Kirk Pollock INSTALLATION: 712 Turner Floor and Wall Tiling Specification. M40 STONE/

More information

URSA MINERAL WOOL URSA Acoustic Roll

URSA MINERAL WOOL URSA Acoustic Roll - 073_Layout 1 02/10/2017 10:19 Page 1 URSA UK LTD Crest House 102-104 Church Road Teddington, Middlesex TW11 8PY United Kingdom Tel : 020 8977 96 97 Fax : 020 8977 94 56 Web : www.ursa-uk.co.uk E-mail

More information

HOW TO: BOARD BATHROOMS, WET ROOMS & SHOWERS

HOW TO: BOARD BATHROOMS, WET ROOMS & SHOWERS HOW TO: BOARD BATHROOMS, WET ROOMS & SHOWERS 1 FOCUS ON GETTING IT RIGHT As with any building project the quality of finish is determined by the foundation upon which it is installed. The most important

More information

The World of Floor Technology

The World of Floor Technology The World of Floor Technology THE POSI-JOIST TECHNICAL HANDBOOK FEATURING An Introduction to Posi-Joist Installation Guidance Posi-Joist Applications throughout your building Acoustic Performance & Separating

More information

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,

More information

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No. SECTION 092900 GYPSUM BOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Assessment Number BTC 14254FA

Assessment Number BTC 14254FA Assessment Number BTC 14254FA A FIRE TEST ASSESSMENT ON A LOADBEARING WALL CONSISTING OF OSB FACE AND POLYURETHANE CORE, CLAD ON THE EXPOSED FACE WITH 19mm GYPROC PLANK AND 12.5mm GYPROC FIRELINE, CONDUCTED

More information

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction Walls And Ceilings Single- And Double-Layer Construction 09 9 00/NGC Single-Layer Construction The single-layer construction system consists of a single layer of Gold Bond brand Gypsum Board applied to

More information

Garage Conversion - Between and Under Joist Applications

Garage Conversion - Between and Under Joist Applications Issue 1, August 2013 CI/SfB (2 -) Rn7 (M2) Garage Conversion - Between and Under Joist Applications Flat Roof Insulation Introduction Celotex is the brand leading manufacturer of PIR insulation boards,

More information

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation.

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation. SECTION B Steel Frame Wall Systems. Contents. SUBJECT Steel Stud Selection Tables Introduction Design Considerations Installation Components PAGE B2 B4 B4 B6 B7 System Specifications Single Stud Staggered

More information

December 2011 OFF-SITE. Off-site solutions

December 2011 OFF-SITE. Off-site solutions December 2011 Off-site solutions Why choose British Gypsum? Off-site manufacturing demands product that is proven, consistent, reliable and robust. British Gypsum has a package of products and services

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 092500 - GYPSUM BOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

BISON PRECAST FLOORING SPECIFICATION

BISON PRECAST FLOORING SPECIFICATION BISON PRECAST FLOORING SPECIFICATION 1.0 SCOPE OF THE SPECIFICATION 1.01 Relates to: This specification covers the design, manufacture and associated site work of the following types of floors:- Hollowcore

More information

June Non - Residential Refurbishment Internal lining walls

June Non - Residential Refurbishment Internal lining walls June 2010 Non - Residential Refurbishment 5.3.4 Internal lining walls Non-residential refurbishment 5.0 Non-residential Refurbishment Internal Lining Walls Contents Introduction find online page Solution

More information

Fire Resistant: Achieves FRL levels of 90/90/90 for load bearing walls.

Fire Resistant: Achieves FRL levels of 90/90/90 for load bearing walls. ( ) is a new and innovative system designed to provide high performance separating walls between units and apartments in low-rise residential and commercial projects. provides exceptional fire and acoustic

More information

GIB Quiet Clip GIB CBI March Features and Benefits

GIB Quiet Clip GIB CBI March Features and Benefits CBI - 5113 March 2002 GIB Quiet Clip Features and Benefits No special flooring systems required Easy fit Installation Significantly improves low frequency sound transmission Significantly improves low

More information

DriLyner rf. Internal wall insulation (IWI) installation guide

DriLyner rf. Internal wall insulation (IWI) installation guide DriLyner rf Internal wall insulation (IWI) installation guide i DriLyner rf Internal wall insulation Pre-Installation survey requirements It is important to note that the survey should be carried out by

More information

The GlasRoc Shaftliner Type X advantage...

The GlasRoc Shaftliner Type X advantage... C e r t a i n T e e d SHAFTLINER F o r A r e a S e p a r a t i o n F i r e w a l l s Shaftliner S Type X for Area Separation GlasRoc Shaftliner is a specially formulated product for applications where

More information

Building Design Data

Building Design Data Building Design Data.. 1. Building Design The KORE ICF System is designed to meet the requirements of the Building Regulations 1997-2006, in the case of two storeys, single occupancy dwellings. If the

More information

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation Recommended Design Considerations and Guide Specifications For Commercial Building Insulation Date of Issue: October 1, 2004 Recommended Design Considerations and Guide Specifications For Commercial Building

More information

Acoustic Cradle Levelling System

Acoustic Cradle Levelling System Acoustic Cradle Levelling System CONCRETE FLOOR CRADLE & BATTEN Datasheet 52 01 18mm t&g chipboard @ 400mm centres 02 40mm min directly applied sand & cement or proprietary screed (min 80kg/m 2 ) 03 03

More information

Gyptone BIG system Installation manual

Gyptone BIG system Installation manual Installation manual Design and specifications Use of the product Gyptone BIG is a gypsum based acoustic ceiling with high design value since no joints are visible. The ceiling can be used for many applications

More information

SINTEF Building and Infrastructure confirms that. Separating floors with Hunton Silencio 36 / Hunton Silencio Thermo

SINTEF Building and Infrastructure confirms that. Separating floors with Hunton Silencio 36 / Hunton Silencio Thermo SINTEF Certification No. 2330 Issued t: 18.02.2002 Revised: 17.06.2013 Valid until: 01.07.2018 Page: 1 of 5 SINTEF Building and Infrastructure confirms that Separating floors with Hunton Silencio 36 /

More information

GenieMat FF. Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation. It s not magic, it s engineering. Impact Sound Control

GenieMat FF. Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation. It s not magic, it s engineering. Impact Sound Control It s not magic, it s engineering. Impact Sound Control GenieMat FF Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation Patents: US 8240430, US8556029, CA 2500956, CA 2503420 GenieMat

More information

PITCHED ROOF SOLUTIONS

PITCHED ROOF SOLUTIONS PITCHED ROOF SOLUTIONS, airtightness and moisture management solutions for pitched roof rafter applications. isover.co.uk Pitched Roof Solutions Building extra living space within the attic is a great

More information

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN STEEL STUD AND TRACK FOR DRYWALL PARTITIONS TAKE ADVANTAGE OF THE SAVINGS IN TIME

More information

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications. SECTION D Wall Systems. Contents. SUBJECT Introduction Design Considerations Installation Components PAGE D2 D2 D4 D5 System Specifications Stud One Side Stud Both Sides Stud and Furring Channel Resilient

More information

WALL CEILING FACADE ACCESSORIES ACCESS PANELS CONTACT CLICK TO START

WALL CEILING FACADE ACCESSORIES ACCESS PANELS CONTACT CLICK TO START CLICK TO START About Knauf Metal Knauf Metal is part of the Knauf Group, leaders in lightweight construction materials, and a major supplier and manufacturer of metal building systems to the Australian

More information

Thermal Laminate Board.

Thermal Laminate Board. Thermal Laminate Board www.speedlinedrywall.co.uk The Dry Lining and Thermal Insulation Solution The Dry Lining and Thermal Insulation Solution Around a third of all heat lost within un-insulated or poorly

More information

Knauf Safeboard. X-ray partitions. Lead-free X-ray shielding plasterboard. 100% lead-free board. Economical radiation protection.

Knauf Safeboard. X-ray partitions. Lead-free X-ray shielding plasterboard. 100% lead-free board. Economical radiation protection. X-ray partitions 100% lead-free board Economical radiation protection Fire resistant Easy to install Excellent acoustic performance Knauf Safeboard Lead-free X-ray shielding plasterboard Introduction Knauf

More information

1. Interior gypsum wallboard. 2. Exterior gypsum board panels for ceilings and soffits. 3. Tile backing panels.

1. Interior gypsum wallboard. 2. Exterior gypsum board panels for ceilings and soffits. 3. Tile backing panels. SECTION 09260 - GYPSUM BOARD ASSEMBLIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Metal ceilings. OWAtecta. OWAtecta Why metal ceilings. Planning with OWAtecta Variety formation of the ceiling

Metal ceilings. OWAtecta. OWAtecta Why metal ceilings. Planning with OWAtecta Variety formation of the ceiling Metal ceilings Why metal ceilings Metal ceilings are different. The density of their surface and the aesthetic restraint of their design offer the architect and builder particular creative options and

More information

Oakdale Primary School Expansion Project

Oakdale Primary School Expansion Project FOR TENDER Page 1 of 200 Table of Contents 15-05-15 Concrete foundation systems... 6 20-10-10 Board ceiling and soffit systems... 7 20-10-20 Demountable suspended ceiling systems... 10 20-15-35 Acrylic

More information

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT MAY 2009 prepared by N. A. JACOBSEN, P.Eng. CIVIL ENGINEERING CONSULTANT Whitehorse, Yukon ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT MAY

More information

LISTING INFORMATION OF Weyerhaeuser - TJI Joists SPEC ID: 26948

LISTING INFORMATION OF Weyerhaeuser - TJI Joists SPEC ID: 26948 LISTING INFORMATION OF Weyerhaeuser - TJI Joists SPEC ID: 26948 Weyerhaeuser NR Company 33663 Weyerhaeuser Way S PO Box 9777, WTC 1K5 Federal Way, WA 98063 This report is for the exclusive use of Intertek

More information

Most products will act differently when installed over an UFH system than when installed on a standard unheated subfloor.

Most products will act differently when installed over an UFH system than when installed on a standard unheated subfloor. Guidance Note on Underfloor Heating DRAFT FOR COMMENT Overview Underfloor heating (UFH) is now an established and appealing and potentially cost effective source of heating, hence its increased popularity

More information

Cavity ShAftwall System

Cavity ShAftwall System 09 9 00/NGC Cavity shaftwall systems are non-load-bearing, -hour to -hour, fire-rated partitions constructed from one side used to enclose elevator shafts, stairs and mechanical shafts where the design

More information

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for Walls Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification

More information

Metal Solutions.

Metal Solutions. Metal Solutions www.speedlinedrywall.co.uk Welcome What is? Speedline is a high performance brand of drywall products and accessories available exclusively from SIG plc stockists. Central to the range

More information

Civil Engineering Construction Chapter 5

Civil Engineering Construction Chapter 5 Civil Engineering Construction Chapter 5 Introduction to Floor Dr Mohamad Syazli Fathi Department of Civil Engineering UTM RAZAK School of Engineering & Advanced Technology UTM International Campus August

More information