Separating walls. Countryside Properties, Lock 38, Stoke-on-Trent

Size: px
Start display at page:

Download "Separating walls. Countryside Properties, Lock 38, Stoke-on-Trent"

Transcription

1 Separating walls Countryside Properties, ock 8, Stoke-on-Trent

2 Separating Masonry walls Walls Separating Masonry wallswalls Approved Document E 200 Clause E Approved Document Requirements Walls >> Separating Walls >> Separating Masonry Walls walls Separating wall constructions must be built to comply with Building Regulations Approved Document E clause E and are subject to Pre-Completion Testing unless a Robust Detail construction is used. Clause E of Approved Document E stipulates the following: Dwelling-houses, flats and rooms for residential purposes shall be designed and constructed in such a way that they provide reasonable resistance to sound from other parts of the same building and from adjoining buildings. Approved Document E 200 Performance standards The following table is adapted from Approved Document E and highlights the minimum performance standards required for separating walls. Please note that the requirement is for airborne sound insulation only. Contrary to previous assumptions, Approved Document will no longer treat separating cavity walls as a zero heat loss element, due to the thermal bypass effect The heat loss can be reduced by measures that restrict air movement through the cavity, either by means of fully-filling the cavity and/or by providing effective sealing around the perimeter. Table - U-values for party walls Party wall construction U-value (W/m 2 K) Solid 0.0 Unfilled cavity with no effective edge sealing 0.5 Unfilled cavity with effective edge sealing around all exposed edges and in line with insulation layers in abutting elements 0.2 A fully filled cavity with effective sealing at all exposed edges and in line with insulation layers in abutting elements 0.0 Walls >> Separating Masonry walls Walls Dwelling-houses and flats - performance standards for separating walls that have a separating function Airborne sound insulation D ntw + Ctr db Inpact sound insulation nt, w db New build separating walls 45 - Rooms for residential purposes - performance standards for separating walls that have a separating function Airborne sound insulation D ntw + Ctr db Inpact sound insulation nt, w db New build separating walls 4 - Roof oft Space oft Insulation Roof oft Space oft Insulation What is the thermal bypass effect? Where outside air is able to flow into the separating wall cavity a cold zone is created which results in heat flux through the wall sections on either side. The extent of air flow and heat flux will depend on external conditions such as wind and temperature and also on the setting up of a ventilation stack effect caused by warmed air rising in the cavity to be replaced by cooler air drawn in from outside. The air movements involved can be significant and, if no steps are taken to restrict flows, the resulting heat losses can be large. How to comply Robust Details - All Robust Details have been approved as capable of meeting or exceeding the E performance criteria, providing they are built correctly. Following these specifications means the construction can be exempt from undertaking Pre Completion Testing. The Robust Details scheme applies to new-build houses and apartments only. Plots must be registered with Robust Details imited prior to construction. NB It is important to check the compatibility of the Robust Detail separating walls with the Robust Detail separating floors. Please refer to for more information. Manufacturers Proprietary Systems - These constructions are British Gypsum Approved Systems, which, provided they are built correctly, have the potential to achieve E performance criteria required for new-build houses and apartments separating floor constructions and new-build rooms for residential purposes. Pre-Completion Testing must be executed on a 0% sample (by type) to demonstrate compliance. st Floor Ground Floor st Floor Ground Floor Isover Party Wall Roll Isover Party Wall Roll is a full-fill glass mineral roll for use in 75mm, 00mm, 25mm and mm separating wall cavities. The product meets the full-fill requirement to deliver a zero U-value for separating party walls as defined in Building Regulations (Approved Document A, Table ). See page 56 for Separating Wall Solutions 29 and 0 and also page 97 for further product information The Within category 7 of the, Health and Wellbeing, section states that up to four credits are available for achieving higher standards of sound insulation than those given in Building Regulations Approved Document E and demonstrating it by using either Pre-Completion Testing or Robust Details. This stamp highlights construction details which have the potential to achieve the number of credits stated, provided they are built correctly. Section 5 - Scotland Section 5 (Scotland) stipulates a minimum airbourne sound performance for separating walls of 56 D ntw db. Please be aware that Scottish Regulations do not recognise a correction factor for low frequency sound. Airbourne sound insulation D ntw db Zero U-values Can be used as part of a solution to achieve Zero U-value solutions This stamp highlights construction details which have potential to achieve a zero U-value, provided they are built correctly. Scotland Scottish regulations also recognise that separating walls should no longer be treated as zero heat loss. Section 6 stipulates the following: To limit heat loss, a separating wall cavity should have effective perimeter sealing around all exposed edges and in line with insulation layers in abutting elements which separate the dwelling from another building or from an unheated space. Further reduction in heat loss can be achieved where the cavity separating wall is also fully filled with a material that limits air movement. Separating walls Isover Technical Advice - Tel: Isover technical advice: isover.enquiries@saint-gobain.com 49

3 E-WM-24 E-WM-24 Separating walls Separating walls Walls >> Separating walls Separating wall solutions The separating wall solutions detailed in this section of the guide are Robust Detail or British Gypsum Approved Systems. These constructions have been tested and proved to meet or exceed the sound insulation values given in the table on page 49. Please note that for British Gypsum Approved Systems Pre-Completion Testing must take place to demonstrate compliance. Separating wall solutions (Robust Details) E-WM-8: Masonry ightweight aggregate blockwork (5mm Isover 5 and Gyproc plasterboard) E-WM-4: Masonry ightweight aggregate blockwork with 00mm cavity (5mm Isover 5 and Gyproc plasterboard) E-WM-5: Masonry aircrete blockwork (5mm Isover 5 and Gyproc plasterboard) E-WM-7: Masonry ightweight aggregate blockwork (Isover Party Wall Roll and Gyproc plasterboard) E-WM-20: Masonry ightweight aggregate blockwork (Isover Party Wall Roll and Gyproc plasterboard) E-WM-24: Masonry Masonry aircrete aggregate blockwork (Isover Party Wall Roll and Gyproc plasterboard) E-WT-: Twin Timber without sheathing board E-WT-2: Twin Timber with sheathing board Airborne sound db (D ntw + Ctr) - site test result Separating wall solutions (British Gypsum Approved) GypWall classic With Gypframe 46 AS AcouStuds GypWall classic With Gypframe 46 AS AcouStuds GypWall quiet GypWall quiet with additional service zone created with Gypyner universal Airbourne sound transmission (R w + Ctr db) - lab test result Walls >> Separating 2 E-WS-: Twin Steel E-WS-2: Steel (Non-loadbearing) Isover Products Isover separating wall solutions incorporate the following Isover products Isover Party Wall Roll Isover 5 Isover Acoustic Partition Roll E-WS-: Twin Steel Modular build steel frame 4 E-WS-4: Twin Steel Isover Acoustic Slab Isover Timber Batt Isover Timber Party Wall Roll 5 Masonry Walls Gypyner universal lining 59 Isover technical advice - Tel: Isover technical advice: isover.enquiries@saint-gobain.com 5

4 Separating Masonry masonry Walls walls Separating Masonry masonry Walls walls Walls Walls >> Separating >> Separating Masonry masonry Walls 2 E-WM-8: Masonry ightweight aggregate blockwork (5mm Isover 5 and Gyproc plasterboard) Overall construction nominal width 20mm ightweight aggregate cavity block wall, minimum 00mm blocks (density - 600kg/m³) Minimum 75mm cavity between leaves Isover 5 in the cavity Nominal 8mm (minimum 6mm) Gyproc Soundcoat Plus C 25 E-WM-5: Masonry Aircrete blockwork (5mm Isover 5 and Gyproc plasterboard) Overall construction nominal width 20mm Aircrete cavity block wall, minimum 00mm blocks (density kg/m³) Minimum 75mm cavity between leaves Isover 5 in the cavity Drylined with 2.5mm Gyproc WallBoard ten, 5mm Gyproc WallBoard or 2.5mm Gyproc SoundBloc dot and dabbed (Driyner basic system) B Walls >> Separating Masonry masonry Walls Drylined with 2.5mm Gyproc WallBoard ten, 5mm Gyproc WallBoard or 2.5mm Gyproc SoundBloc dot and dabbed (Driyner basic system) 24 E-WM-4: Masonry ightweight aggregate blockwork with 00mm cavity (5mm Isover 5 and Gyproc plasterboard) Overall construction nominal width 45mm ightweight aggregate cavity block wall, minimum 00mm blocks (density - 600kg/m³) Minimum 00mm cavity between leaves Isover 5 in the cavity Drylined with 2.5mm Gyproc WallBoard ten, 5mm Gyproc WallBoard or 2.5mm Gyproc SoundBloc dot and dabbed (Driyner basic system) C s 26 E-WM-7: Masonry ightweight aggregate blockwork (Isover Party Wall Roll and Gyproc plasterboard) Overall construction nominal width 20mm ightweight aggregate cavity block wall, minimum 00mm blocks (density 600kg/m³) or Plasmor Aglite Ultima 0 kg/m cavity block wall Minimum 75mm cavity between leaves Minimum 75mm Isover Party Wall Roll in the cavity Drylined with dot and dabbed 2.5mm Gyproc WallBoard ten, 5mm Gyproc WallBoard or 2.5mm Gyproc SoundBloc B Zero U-values Can be used as part of a solution to achieve 52 Isover technical advice - Tel: Isover technical advice: isover.enquiries@saint-gobain.com 5

5 E-WM-24 E-WM-24 Separating masonry walls Separating masonry walls Walls >> Separating masonry 27 E-WM-20: Masonry ightweight aggregate blockwork (Isover Party Wall Roll and Gyproc plasterboard) Overall construction nominal width 45mm ightweight aggregate cavity block wall, minimum 00mm blocks (density 600kg/m³) Minimum 00mm cavity between leaves Minimum 00mm Isover Party Wall Roll in the cavity Drylined with dot and dabbed 2.5mm Gyproc WallBoard ten, 5mm Gyproc WallBoard or 2.5mm Gyproc SoundBloc Zero U-values Can be used as part of a solution to achieve B 29 Masonry walls Gypyner universal lining Core masonry element mass per unit area minimum 200Kg/m², e.g. 00mm high density aggregate blocks Gypyner universal wall lining to one side of wall with minimum 85mm cavity (framing at 600mm centres) ined with double layer of 2.5mm Gyproc SoundBloc, mm Isover Acoustic Partition Roll (APR 200) in the cavity Other side lined with either 2.5mm Gyproc WallBoard on the Driyner basic system or mm Thistle plaster finish Nominal width 22mm (drylined) or 22mm (plastered) 59dB R w + Ctr PSR B Rw 66dB Walls >> Separating masonry 28 E-WM-24: Masonry Masonry aircrete blockwork (Isover Party Wall Roll and Gyproc plasterboard) B 0 E-WT-: Timber frame Without sheathing board 60mins BS A+ Aircrete cavity block wall, minimum 00mm blocks (density kg/m ) Minimum 00mm cavity between leaves Minimum 00mm Isover Party Wall Roll in the cavity Overall construction nominal width 00mm Cavity width minimum 240mm, gap of minimum mm between frames 90mm Isover Timber Batt 40 positioned between the studs in each timber frame Drylined with 2.5mm Gyproc WallBoard dot and dabbed (Driyner basic system) - Inner ayer of 9mm Gyproc Plank, outer layer of 2.5mm Gyproc WallBoard each side Double layer of 5mm Gyproc SoundBloc each side, Zero U-values Can be used as part of a solution to achieve Double layer of 5mm Gyproc Fireine each side, Inner layer of 9mm Gyproc Plank, outer layer of 2.5mm Gyproc Fireine each side Isover technical advice - Tel: Isover technical advice: isover.enquiries@saint-gobain.com

6 Separating timber frame walls Separating steel frame walls Walls >> Separating timber frame E-WT-2: Timber frame With sheathing board Overall construction nominal width 00mm Cavity width minimum 240mm, gap of minimum mm between frames Minimum mm gap between sheathing panels 90mm Isover Batt 40 positioned between the studs in each timber frame 60mins BS A+ or A- E-WS-2: Steel frame (non-loadbearing) Overall construction nominal width 2mm Minimum cavity width 90mm Gypframe I Studs minimum 60mm depth (no bracing between leaves) 00mm Isover Acoustic Partition Roll (APR 200) positioned between the frames D - Inner layer of 9mm Gyproc Plank, outer layer of 2.5mm Gyproc WallBoard each side - Double layer of 5mm Gyproc SoundBloc each side, - Double layer of 5mm Gyproc Fireine each side, - Inner layer of 9mm Gyproc Plank, outer layer of 2.5mm Gyproc Fireine each side Depending on sheathing board specified. Please refer to for further information - Double layer of 5mm Gyproc SoundBloc each side (for 90 minutes BS and EN ) - Double layer of 5mm Gyproc SoundBloc each side overboard with one layer of 2.5mm Gyproc Fireine each side (for 20 minutes BS and EN fire resistance) NB: Fully-fill cavity with Isover Timber Party Wall Roll to help achieve a zero U-value wall 2 E-WS-: Steel frame 60mins BS A+ 4 E-WS-: Steel frame Modular build steel frame 60mins BS B or C 2 For use in lightweight steel frame housing or flats / apartments Only for use in lightweight steel frame housing or flats / apartments Minimum cavity width 200mm Overall construction nominal width 264mm oadbearing studs Minimum 72mm or 00mm loadbearing studs Overall construction nominal width 26mm Minimum 40mm gap between sheathing panels mm Isover Batt 2 positioned between the frames 25mm Isover Acoustic Partition Roll (APR 200) between the studs in each frame - Inner layer of 9mm Gyproc Plank, outer layer of 2.5mm Gyproc WallBoard each side - Double layer of 5mm Gyproc SoundBloc each side Subject to manufacturers substantiation based on their loadbearing stud Minimum 75mm minimal Isover TS48 Slab (45Kg/m³) positioned between the studs - 72mm studs - double layer of 5mm Rigidur h - 00mm studs - double layer of 2.5mm Rigidur h Depending on sheathing board specified. Please refer to for further information 56 Isover technical advice - Tel: Isover technical advice: isover.enquiries@saint-gobain.com 57

7 Separating steel frame walls Separating steel frame walls 5 E-WS-4: Steel frame Only for use in lightweight steel frame housing or flats / apartments Minimum cavity width 2mm Overall construction nominal width mm Minimum 75mm loadbearing C studs 60mins BS A s 7 GypWall classic With Gypframe 46 AS AcouStuds Pre-Completion Testing - British Gypsum Approved System Overall construction nominal width 208mm Gypframe 46 AS AcouStuds at 600mm centres mm Isover Acoustic Partition Roll (APR 200) in the cavity ined with a double layer of 5mm Gyproc SoundBloc each side 57dB 90mm Isover Timber Batt 2 positioned between the frames - Inner layer of 9mm Gyproc Plank, outer layer of 2.5mm Gyproc WallBoard each side - Double layer of 5mm Gyproc SoundBloc each side Subject to manufacturers substantiation based on their loadbearing stud ined with a double l ayer of 5mm Gyproc Duraine for 20 minutes PSR A206A255 6 GypWall classic With Gypframe 46 AS AcouStuds 8 GypWall quiet 56dB 5dB Overall construction nominal width 208mm Overall construction nominal width 200mm Gypframe 46 AS AcouStud at 600mm centres mm Isover Acoustic Partition Roll (APR 200) in the cavity ined with a double layer of 5mm Gyproc SoundBloc each side Two frames of 48mm Gypframe C Stud at 600mm centres, cross braced at 200mm centres Cavity width of 40mm mm Isover Acoustic Partition Roll (APR 200) positioned between the frames ined with a double layer of 5mm Gyproc Duraine for 20 minutes PSR A206A24 ined with a double layer of 5mm Gyproc SoundBloc each side ined with a double layer of 5mm Gyproc Fireine for 20 minutes PSR A26009/ Isover technical advice - Tel: Isover technical advice: isover.enquiries@saint-gobain.com 59

8 Separating steel frame walls Separating steel frame walls 9 GypWall quiet Pre-Completion Testing - British Gypsum Approved System Overall construction nominal width 2mm Two frames of 48mm Gypframe C Stud at 600mm centres, cross braced at 200mm centres Cavity width of 90mm 75mm Isover Acoustic Slab positioned between the frames ined with a double layer of 5mm Gyproc SoundBloc each side ined with a double layer of 5mm Gyproc Duraine for 20 minutes 57dB PSR A260 R w 6dB 4 With additional service zone created with Gypyner universal 54dB Base separating wall, A wall lining with: Minimum 70mm cavity Minimum mm Isover Acoustic Partition Roll (APR 200) in the cavity Single layer of 5mm Gyproc SoundBloc installed on one or both sides of the base construction (for base construction refer to ) This solution can be used without lowering the acoustic performance of dB 5dB 20mins BS Overall construction nominal width 48mm Overall construction nominal width 48mm 70mm Gypframe C Studs at 600mm centres with Gypframe RB Resilient Bar at 600mm centres fixed to one side of the studs 70mm Gypframe C Studs at 600mm centres with Gypframe RB Resilient Bar at 600mm centres fixed to one side of the studs mm Isover Acoustic Partition Roll (APR 200) positioned in the cavity mm Isover Acoustic Partition Roll (APR 200) positioned in the cavity ined with a double layer of 5mm Gyproc SoundBloc each side ined with a inner layer of 5mm Gyproc Fireine and an outer layer of 5mm Gyproc Duraine ined with a double layer of 5mm Gyproc Duraine for 20 minutes PSR A6009 PSR Q Isover technical advice - Tel: Isover technical advice: isover.enquiries@saint-gobain.com 6

9 Separating steel frame walls 4 Pre-Completion Testing - British Gypsum Approved System ( 45 db D ntw + Ctr) Overall construction nominal width 200mm Two frames of Gypframe 48 I I Studs at 600mm centres Cavity width of 40mm wide mm Isover Acoustic Partition Roll (APR 200) positioned in the cavity 58dB R w 66dB ined with a double layer of 5mm Gyproc SoundBloc each side A26D4 44 Pre-Completion Testing - British Gypsum Approved System 62dB R w 70dB Overall construction nominal width 2mm Two frameworks of Gypframe 60 I I Stud Cavity width of 90mm wide 00mm Isover Acoustic Partition Roll (APR 200) in the cavity ined with a double layer of 5mm Gyproc SoundBloc each side A Isover technical advice - Tel:

WORK, REST AND PLAY ISOVER MAKES IT POSSIBLE.

WORK, REST AND PLAY ISOVER MAKES IT POSSIBLE. Quiet Living WORK, REST AND PLAY ISOVER MAKES IT POSSIBLE. Isover s built in sound control. Simply building to the minimum sound standards outlined in the Building Regulations won t provide the comfort

More information

Issue date: 1st May Key changes since original publication (July 2005):

Issue date: 1st May Key changes since original publication (July 2005): Issue date: st May 008 Key changes since original publication (July 00): May 008 Pages 0 & tables a & b - spec A06A08 Sound Insulation changed from 0 to 9 Rw db rating. September 00 Pages 66 & 6 tables

More information

June Residential Refurbishment Separating walls

June Residential Refurbishment Separating walls June 2010 Residential Refurbishment 3.6.1 Separating walls Residential refurbishment 3.0 Residential Refurbishment Separating Walls Contents Introduction find online page Solution optimiser and pathfinder

More information

Selecting partitions

Selecting partitions email: bgtechnical.enquiries@bpb.com www.british-gypsum.com/health Introduction 6 Performance matrix 8 Worked examples 0 your partition type Solutions up to R w db This section will guide you through the

More information

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner UNIVERSAL Metal framed wall lining system Metal framed wall lining system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated 0/0/00 Cadbury

More information

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner UNIVERSAL Metal framed wall lining system Metal framed wall lining system Pizza Express, York 30 Metal framed wall lining system wall lining system is a cost-effective, virtually independent metal frame drylining. It is a general purpose system

More information

Loadbearing timber joist floors

Loadbearing timber joist floors C06 Floors and ceilings Internal and separating floor systems Timber joists are widely used within internal floor and separating floor construction, both in residential and coercial applications. Our range

More information

Tiling Tiling Finishes C08

Tiling Tiling Finishes C08 C08 Finishes In rooms subject to high or intermittent moisture conditions, the range of boards available for tiling offers flexibility of design and peace of mind when installed in both wall linings, lightweight

More information

Staggered stud acoustic partition system

Staggered stud acoustic partition system C0 Partitions Staggered stud acoustic partition system All our systems are covered by SpecSure when using genuine Gyproc and Isover products is a non-loadbearing stud partition incorporating a single framework

More information

Tiling Tiling

Tiling Tiling 416 Tiles can be applied to drylined walls or the surface of lightweight partition systems to dado level or above. can be carried out in any type of building either in dry areas or in areas subject to

More information

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products. GypLyner GypLyner Metal framed wall lining system All our systems are covered by SpecSure when using genuine Gyproc and Isover products Linings GypLyner GypLyner is a cost-effective, virtually independent

More information

CasoLine MF Concealed grid MF suspended ceiling system

CasoLine MF Concealed grid MF suspended ceiling system Concealed grid MF suspended ceiling system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated

More information

CasoLine MF Concealed grid MF suspended ceiling system

CasoLine MF Concealed grid MF suspended ceiling system Concealed grid MF suspended ceiling system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated

More information

Staggered stud acoustic partition system

Staggered stud acoustic partition system GypWall STAGGERED GypWall STAGGERED Staggered stud acoustic partition system GypWall STAGGERED is a nonloadbearing metal stud partition which provides very high levels of sound insulation. In public and

More information

GypLyner (walls) Metal framed wall lining system. GypLyner.

GypLyner (walls) Metal framed wall lining system. GypLyner. GypLyner GypLyner (walls) Metal framed wall lining system GypLyner is a cost-effective, virtually independent metal frame drylining system for lining walls. General purpose and suitable for all internal

More information

The extra strong, extra durable, sound resistant system that you can direct fix to

The extra strong, extra durable, sound resistant system that you can direct fix to C0 Partitions The extra strong, extra durable, sound resistant system that you can direct fix to All our systems are covered by SpecSure when using genuine Gyproc and Isover products gyproc.ie Utilising

More information

C05. S03. P02 P08 FireWall

C05. S03. P02 P08 FireWall ! This section includes updated information, added since it was first published in December 2015. Last updated 16/12/2016 C05. S03. P02 P08 Including C05. S01. P02 Specialist partitions introduction C05

More information

ShaftWall. Shaft and duct encasement system. ShaftWall.

ShaftWall. Shaft and duct encasement system. ShaftWall. ShaftWall ShaftWall Shaft and duct encasement system ShaftWall provides a lightweight, non-loadbearing fire-resistant structure to protect elements within the service cores of modern fast-track developments.

More information

Isover Installation Guide

Isover Installation Guide Isover Installation Guide Installing Separating Masonry Cavity Wall Insulation At Saint-Gobain Isover we develop sustainable insulation solutions to protect both your built environment and the natural

More information

Product Information Sheet

Product Information Sheet Product Information Sheet Product Name ISOVER Metac - high performance insulation Metac G3 Touch is a high performance low lambda mineral wool insulation roll with both excellent thermal and acoustic properties.

More information

SOUND SOLUTIONS TO MEET THE APPROVED DOCUMENT E (2003 EDITION) August 2008

SOUND SOLUTIONS TO MEET THE APPROVED DOCUMENT E (2003 EDITION) August 2008 SOUND SOLUTIONS TO MEET THE APPROVED DOCUMENT E (2003 EDITION) August 2008 PART E AT A GLANCE The New Approved Document E, (2003 Edition) was implemented on 1st July 2003. This applies to houses, flats,

More information

Tiling. Capital Gate Hotel, Abu Dhabi - UAE

Tiling.  Capital Gate Hotel, Abu Dhabi - UAE 166 202 Capital Gate Hotel, Abu Dhabi - UAE Tiles can be applied to drylined walls or to the surface of lightweight partition systems. can be carried out in any type of building, either in dry areas or

More information

SOUND INSULATION TESTING IN DWELLINGS

SOUND INSULATION TESTING IN DWELLINGS SOUND INSULATION TESTING IN DWELLINGS Chris Dilworth, AWN Consulting This Presentation Discusses the standards by which we judge sound insulation performance. Presents the results of sound insulation tests

More information

Part E robustdetails. robustdetails. April 2017 Update Pack. Dear Colleague,

Part E robustdetails. robustdetails. April 2017 Update Pack. Dear Colleague, Part E Pack Dear Colleague, Following on from the two new Details already issued this year, this update sees the URSA PARTY WALL ROLL added as a further option in the cavity masonry wall E-WM-22. This

More information

Quantity take-off details

Quantity take-off details Quantitiy take-off details 6 Quantity take-off details Quantities Choose system specification / height or area as required, as given in the left hand column. Read across the columns to determine the quantity

More information

Boards. Products - Boards.

Boards. Products - Boards. Products - Boards Boards Gyproc plasterboards are the ultimate lining solution for today's buildings, providing high levels of fire, sound, thermal, moisture and impact resistance to create modern internal

More information

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague, Part E Pack Dear Colleague, This is the first 2017 update to the Part E Robust Details Handbook. In this update pack, we have focussed on clarifying the situation on incorporating underfloor heating (UFH)

More information

C06. S02. P02 P22 CasoLine mf

C06. S02. P02 P22 CasoLine mf ! This section includes updated information, added since it was first published in December 0. Last updated 6//06 C06. S0. P0 P CasoLine mf Including C06. S0. P0 P08 Floors and ceilings introduction C06

More information

CI/SfB. November Design Guide Concrete block masonry

CI/SfB. November Design Guide Concrete block masonry CI/SfB November 1997 Ff Design Guide Concrete block masonry Design Guide concrete block masonry This Topblock Design Guide contains detailed information on the design and performance of constructions using

More information

C05. S02. P02 P30 ShaftWall

C05. S02. P02 P30 ShaftWall ! This section includes updated information, added since it was first published in December 0. Last updated 0//0 C0. S0. P0 P0 Including C0. S0. P0 Specialist partitions introduction C0 Specialist partitions

More information

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red Plant Areas External plant must meet the following noise suppression requirement as adopted by the Landlord: 1. Air handling units 45db measured at 3metres from source. 2. Heat rejection plant 45db measured

More information

Part E robustdetails. robustdetails. September 2017 Update Pack. Dear Colleague,

Part E robustdetails. robustdetails. September 2017 Update Pack. Dear Colleague, Part E Pack Dear Colleague, 207 has been very busy for us, with this one being the fifth update to the Handbook in one year the first time this has ever happened. In this update pack, we are pleased to

More information

URSA MINERAL WOOL URSA Acoustic Roll

URSA MINERAL WOOL URSA Acoustic Roll - 073_Layout 1 02/10/2017 10:19 Page 1 URSA UK LTD Crest House 102-104 Church Road Teddington, Middlesex TW11 8PY United Kingdom Tel : 020 8977 96 97 Fax : 020 8977 94 56 Web : www.ursa-uk.co.uk E-mail

More information

June Non - Residential Refurbishment Internal lining walls

June Non - Residential Refurbishment Internal lining walls June 2010 Non - Residential Refurbishment 5.3.4 Internal lining walls Non-residential refurbishment 5.0 Non-residential Refurbishment Internal Lining Walls Contents Introduction find online page Solution

More information

CO9. Sound absorbing solutions C09

CO9. Sound absorbing solutions C09 ! This section includes updated information, added since it was first published in December 05. Section Last updated Introduction /0/06 CasoLine mf /05/07 CasoLine curve /05/07 GypLyner universal /05/07

More information

The ecological choice. Besblock STAR PERFORMER. The multi-purpose energy saving block JULY 2014 UNIVERSAL, COST EFFECTIVE, DELIVERABLE

The ecological choice. Besblock STAR PERFORMER. The multi-purpose energy saving block JULY 2014 UNIVERSAL, COST EFFECTIVE, DELIVERABLE Besblock STAR PERFORMER UNIVERSAL, COST EFFECTIVE, DELIVERABLE The multi-purpose energy saving block The ecological choice JULY 2014 UNIVERSAL, COST EFFECTIVE, DELIVERABLE besblock.com Besblock STAR PERFORMER

More information

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for Walls Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification

More information

December 2011 OFF-SITE. Off-site solutions

December 2011 OFF-SITE. Off-site solutions December 2011 Off-site solutions Why choose British Gypsum? Off-site manufacturing demands product that is proven, consistent, reliable and robust. British Gypsum has a package of products and services

More information

SOUND SOLUTIONS FOR YOUR HOME. Controlling the volume of everyday living How to solve a problem you have with noise

SOUND SOLUTIONS FOR YOUR HOME. Controlling the volume of everyday living How to solve a problem you have with noise SOUND SOLUTIONS FOR YOUR HOME Controlling the volume of everyday living How to solve a problem you have with noise How to reduce unwanted noise within your home Improve your home s sound insulation for

More information

CO3. Steel encasements C03. Introduction - FireCase 01/12/2017 GypLyner encase 11/05/2017. Introduction Steel encasements

CO3. Steel encasements C03. Introduction - FireCase 01/12/2017 GypLyner encase 11/05/2017. Introduction Steel encasements ! This section includes updated information, added since it was first published in ecember 05. Section Last updated Introduction - FireCase 0//07 GypLyner encase /05/07 Introduction Steel encasements C03

More information

F L O O R S A N D C E I L I N G S

F L O O R S A N D C E I L I N G S INTRODUCTION Contents Performance Tables 163 Lafarge plasterboard direct to timber ceilings 179 Cormet Dryliner to timber joist floors 187 Cormet Dryliner to concrete floors 193 Cormet Suspended Metal

More information

Acoustic Detailing For Steel Construction

Acoustic Detailing For Steel Construction SCI PUBLICATION P372 Acoustic Detailing For Steel Construction A G J Way MEng CEng MICE G H Couchman MA PhD CEng MICE Published by: The Steel Construction Institute Silwood Park Ascot Berkshire SL5 7QN

More information

9/24/2015. Aalto! / ENG + ARC. Asuinrakennusten rakenneratkaisut. Requirements : Sound insulation requirements : Thermal insulation requirements :

9/24/2015. Aalto! / ENG + ARC. Asuinrakennusten rakenneratkaisut. Requirements : Sound insulation requirements : Thermal insulation requirements : Aalto! / ENG + ARC Asuinrakennusten rakenneratkaisut Requirements : Sound insulation requirements : Thermal insulation requirements : 1 Wall structures : Concrete wall : Concrete outer cover (with cavities)

More information

PITCHED ROOF SOLUTIONS

PITCHED ROOF SOLUTIONS PITCHED ROOF SOLUTIONS, airtightness and moisture management solutions for pitched roof rafter applications. isover.co.uk Pitched Roof Solutions Building extra living space within the attic is a great

More information

Ceiling Attenuation Class Systems SYSTEMS 280

Ceiling Attenuation Class Systems SYSTEMS 280 SYSTEMS 280 Ceiling Attenuation Class Ceiling Attenuation Class (CAC) ceiling systems display resistance to sound passing up and over a wall. The sound insulation rating given for the ceiling system indicates

More information

THE FRAME RESIDENTIAL DEVELOPMENT, SPORTCITY, MANCHESTER THE CONCRETE CENTRE LTD 1.0 INTRODUCTION...2

THE FRAME RESIDENTIAL DEVELOPMENT, SPORTCITY, MANCHESTER THE CONCRETE CENTRE LTD 1.0 INTRODUCTION...2 Concrete Centre Limited The Frame Residential Development, Sport City, Manchester Sound Insulation Test Report 2 August 2005 PROJECT: CLIENT: The Frame Residential Development, Sportcity, Manchester Concrete

More information

Metal Solutions.

Metal Solutions. Metal Solutions www.speedlinedrywall.co.uk Welcome What is? Speedline is a high performance brand of drywall products and accessories available exclusively from SIG plc stockists. Central to the range

More information

URSA MINERAL WOOL URSA Cavity Batts

URSA MINERAL WOOL URSA Cavity Batts s 073_Layout 1 02/10/2017 10:18 Page 1 UK LTD Crest House 102-104 Church Road Teddington, Middlesex TW11 8PY United Kingdom Tel : 020 8977 96 97 Fax : 020 8977 94 56 Web : www.ursa-uk.co.uk E-mail : ursauk@ursa.com

More information

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for Walls Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification

More information

June Residential New Build Render and cladding walls

June Residential New Build Render and cladding walls June 2010 Residential New Build 2.5.4 Render and cladding walls Residential new build 2.0 Residential New Build Render and Clad Contents Introduction find online page Solution optimiser and pathfinder

More information

Thermal Laminate Board.

Thermal Laminate Board. Thermal Laminate Board www.speedlinedrywall.co.uk The Dry Lining and Thermal Insulation Solution The Dry Lining and Thermal Insulation Solution Around a third of all heat lost within un-insulated or poorly

More information

The Revolutionary New Plasterboard TIMBER FRAME GUIDE

The Revolutionary New Plasterboard TIMBER FRAME GUIDE The Revolutionary New Plasterboard TIMBER FRAME GUIDE 2 HABITO BOARD is a stronger plasterboard that provides enhanced sound insulation, extra durability and for the first time, direct fixing capability.

More information

BISON PRECAST FLOORING SPECIFICATION

BISON PRECAST FLOORING SPECIFICATION BISON PRECAST FLOORING SPECIFICATION 1.0 SCOPE OF THE SPECIFICATION 1.01 Relates to: This specification covers the design, manufacture and associated site work of the following types of floors:- Hollowcore

More information

Product Application Guide

Product Application Guide Product Application Guide Contents 4 6 14 22 36 42 52 60 Introduction Building Regulations Floors Walls Pitched Roofs Warm Flat Roofs Cladding Fire Protection Introduction to the ROCKWOOL Group...4 Fire..........................................

More information

Aircrete blocks product guide

Aircrete blocks product guide Hanson Building Products Aircrete blocks Customer Services: T: 08705 626500 F: 08705 626550 E: thermalitesales@hanson.com W: www.hanson.com/uk/thermalite Hanson Building Products 6 Pembroke Road Sevenoaks

More information

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation.

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation. SECTION B Steel Frame Wall Systems. Contents. SUBJECT Steel Stud Selection Tables Introduction Design Considerations Installation Components PAGE B2 B4 B4 B6 B7 System Specifications Single Stud Staggered

More information

CHAPTER 3: Modern Methods of Construction (MMC)

CHAPTER 3: Modern Methods of Construction (MMC) CONTENTS 3.1.1 INTRODUCTION 3.1.2 SUITABILITY OF SYSTEMS AND COMPONENTS 3.1.3 TYPES OF MODERN METHODS OF CONSTRUCTION (MMC) 3.1.4 SUITABILITY OF SYSTEMS TO MEET WARRANTY REQUIREMENTS 3.1.5 INSULATED CONCRETE

More information

HP Partial Fill. Robust, long-lasting protection

HP Partial Fill. Robust, long-lasting protection 1 CONSTRUCTION TYPE: cavity walls HP Partial Fill Cavity Walls Robust, long-lasting protection HP Partial Fill slabs have a robust outer surface, designed to withstand on-site rigours and maintain a clearly

More information

Suspended Timber Floor Applications Can be used with Floorboards or Tongue & Groove floor paneling Aluminium Foil Bubble Insulation Joist end Fitting General Purpose Insulation Dry Lining Insulation System

More information

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications. SECTION D Wall Systems. Contents. SUBJECT Introduction Design Considerations Installation Components PAGE D2 D2 D4 D5 System Specifications Stud One Side Stud Both Sides Stud and Furring Channel Resilient

More information

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Xtratherm Thin-R Thermal Liner (XT/TL Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 4 Xtratherm Thin-R Thermal Liner (XT/TL Grade) PRODUCT DESCRIPTION: This Detail Sheet relates to Xtratherm Thin-R Thermal Liner, as defined in NSAI Agrément Certificate

More information

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW.

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW. AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW www.stromatech.com AIR BARRIER DESIGN PRINCIPLES Building Regulations Approved Document Parts L1A & L2A currently requires that new buildings have to achieve a

More information

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System. Suspended Timber Floor Applications Can be used with Floorboards or Tongue & Groove floor paneling Aluminium Foil Bubble Insulation Joist end Fitting General Purpose Insulation Dry Lining Insulation System

More information

CI/SfB (23) Suspended Timber Floor Applications Can be used with Floorboards or Tongue & Groove floor paneling Joist end Fitting Aluminium Foil Bubble Insulation General Purpose Insulation Dry Lining Insulation

More information

RAINSCREEN DUO SLAB. Non-combustible thermal insulation

RAINSCREEN DUO SLAB. Non-combustible thermal insulation RAINSCREEN DUO SLAB Non-combustible thermal insulation RAINSCREEN DUO SLAB Effective, non-combustible thermal insulation for ventilated rainscreen and overcladding applications RAINSCREEN DUO SLAB is a

More information

TECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9

TECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9 MARKINGWALLING OF SAFETY GLASS SPANDREL CURTAIN PANELS FORMED TO COLDFROM ROOFS STACKED WINDOW 7.2 /25 January ARRANGEMENTS (First Issue) XXXX EXXON QUESTION Which factors should be taken into account

More information

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for Walls Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification

More information

Benefits.

Benefits. PARTITIONING Systems Stud & Track An economical friction-fit system to assemble frames for strong, compact, lightweight non load-bearing partitions. The metal stud partitioning is ideal for use in domestic

More information

appended hereto: E119-10b 252: 2008

appended hereto: E119-10b 252: 2008 CERTIFICATE OF APPROVALL No ME 5050 SAINTGOBAIN GYPROC MIDDLE Office 3302,Saba 1,Jumeirah Lake Towers, Dubai, U.A.E, P.O. Box 261107 Tel: +971 4 881 3515 Tel: 800 GYPROC (497762) Have been assessed against

More information

CERTIFICATE OF APPROVAL No CF 517 FSI LIMITED

CERTIFICATE OF APPROVAL No CF 517 FSI LIMITED CERTIFICATE OF APPROVAL No CF 517 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Westminster Industrial

More information

Acoustic Cradle Levelling System

Acoustic Cradle Levelling System Acoustic Cradle Levelling System CONCRETE FLOOR CRADLE & BATTEN Datasheet 52 01 18mm t&g chipboard @ 400mm centres 02 40mm min directly applied sand & cement or proprietary screed (min 80kg/m 2 ) 03 03

More information

Knauf MF Suspended Ceilings

Knauf MF Suspended Ceilings Suspended Ceilings The Suspended Ceiling system is versatile and easy to install. Deep voids are easily created to hide services and the ceiling can be used to provide fire protection. Metal Components

More information

The Passive Fire Protection Handbook

The Passive Fire Protection Handbook The Passive Fire Protection Handbook The UK s comprehensive guide to passive fire protection Chapter Ceilings, Floors and Roofs AUGUST 0 The Passive Fire Protection Handbook Contents Chapter : Introduction

More information

Floors Walls Roofs. Jablite Premium board Jablite board. APPLICATION: Internally Lined Pitched Roof PRODUCTS: Vencel Resil Limited

Floors Walls Roofs. Jablite Premium board Jablite board. APPLICATION: Internally Lined Pitched Roof PRODUCTS: Vencel Resil Limited Floors Walls Roofs APPLICATION: Internally Lined Pitched Roof PRODUCTS: Jablite Premium board Jablite board Vencel Resil Limited Head Office: Infinity House, Anderson Way, Belvedere, Kent DA17 6BG Tel:

More information

Structural Products. Multideck 50-V3 Galvanised Steel Floor Decking System

Structural Products. Multideck 50-V3 Galvanised Steel Floor Decking System Structural Products & Systems Multideck Multideck 50-V3 Galvanised Steel Floor Decking System Meadowhall Extension, Sheffield UK. Image courtesy of MSW (UK) Ltd. 2 Introduction Structural Products & Systems,

More information

SECTION E Ceiling Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications. Floor/Ceiling Systems

SECTION E Ceiling Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications. Floor/Ceiling Systems SECTION E Ceiling Systems. Contents. SUBJECT Introduction Design Considerations Installation Components PAGE E2 E2 E4 E4 System Specifications Floor/Ceiling Systems Roof/Ceiling Systems E6 E12 Floor or

More information

ACOUSTIC SUPPLIES. For Acoustic Solutions you can SHOUT about

ACOUSTIC SUPPLIES. For Acoustic Solutions you can SHOUT about ACOUSTIC SUPPLIES For Acoustic Solutions you can SHOUT about Soundproofing and Sound Absorption Products for all types of Residential and Commercial Projects Whatever your acoustic problem, we have a solution.

More information

BUILDING INSULATION PRODUCT AND DELIVERY GUIDE

BUILDING INSULATION PRODUCT AND DELIVERY GUIDE April 2018 BUILDING INSULATION PRODUCT AND DELIVERY GUIDE isover.co.uk Building Insulation and Delivery Guide Contents Customer Service Charter Our commitment to you 3 Ordering 4-7 Additional Delivery

More information

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250 FIRE PROTECTION GTEC Shaftwall range uses a specially designed system to protect voids and shafts in buildings. It resists pressure changes and enables installation from one side of the shaft only. GTEC

More information

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185 Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185 GENERAL REQUIREMENTS 185 FRAMING 185 PLASTERBOARD LAYOUT 189 PLASTERBOARD FIXING 190 EXTERIOR

More information

Multi-layer Insulation Blanket for use in Walls

Multi-layer Insulation Blanket for use in Walls To order Superquilt online for free delivery within the UK Mainland visit www.ecohome-insulation.com or call 0844 9919949 To order Superquilt online for delivery within Europe and pay online by Euro visit

More information

Specialists in Acoustic Flooring and House to Flat Conversions

Specialists in Acoustic Flooring and House to Flat Conversions Sound Solution Consultants Ltd Po Box 755 Capel St Mary Ipswich Suffolk IP9 2WF Tel No: 0845 5212096 Fax No: 0845 5212097 Email: mpconsultservice@aol.com Specialists in Acoustic Flooring and House to Flat

More information

URSA 20 Plus and URSA 20

URSA 20 Plus and URSA 20 URSA GLASSWOOL E-mail : ursauk@uralita.com URSA UK LTD Crest House 102-104 Church Road Teddington, Middlesex TW11 8PY United Kingdom Tel : 020 8977 96 97 Fax : 020 8977 94 56 Web : www.ursa-uk.co.uk E-mail

More information

URSA MINERAL WOOL URSA HOMETEC Cladding Roll

URSA MINERAL WOOL URSA HOMETEC Cladding Roll Clad 073_Layout 1 02/10/2017 10:37 Page 1 UK LTD Crest House 102-104 Church Road Teddington, Middlesex TW11 8PY United Kingdom Tel : 020 8977 96 97 Fax : 020 8977 94 56 Web : www.ursa-uk.co.uk E-mail :

More information

CI/Sfb (2 ) Rn7 M2 Fourth Issue June Product Selector INSULATION FOR ROOFS, WALLS & FLOORS. Low Energy Low Carbon Buildings

CI/Sfb (2 ) Rn7 M2 Fourth Issue June Product Selector INSULATION FOR ROOFS, WALLS & FLOORS. Low Energy Low Carbon Buildings Insulation CI/Sfb (2 ) Rn7 M2 Fourth Issue June 2011 Product Selector INSULATION FOR ROOFS, WALLS & FLOORS Visit our brand new website: www.kingspaninsulation.co.uk Low Energy Low Carbon Buildings Kingspan

More information

Plasterboard accessories - Products

Plasterboard accessories - Products www.british-gypsum.com Gyproc plasterboard accessories The Gyproc range of accessories includes everything you need to finish plasterboard linings and partitions ready for decoration. Every stage is catered

More information

September Saddle Flooring Systems

September Saddle Flooring Systems September 2011 Saddle Flooring Systems Saddle Flooring Systems Saddle System Principles CMS Danskin Saddle Flooring Systems are dry floating floors which provide an easily levelled understructure for supporting

More information

Building Design Data

Building Design Data Building Design Data.. 1. Building Design The KORE ICF System is designed to meet the requirements of the Building Regulations 1997-2006, in the case of two storeys, single occupancy dwellings. If the

More information

Important Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA

Important Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA Important Notice In August 1, 2013, PABCO Gypsum, a division of PABCO building products, LLC acquired the QuietRock business and operations from Serious Energy, Inc. Serious Energy, Inc. corporate structure

More information

Important Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA

Important Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA Important Notice In August 1, 2013, PABCO Gypsum, a division of PABCO building products, LLC acquired the QuietRock business and operations from Serious Energy, Inc. Serious Energy, Inc. corporate structure

More information

Hollowcore Floors. The ideal structural floor solution for all building types in all sectors.

Hollowcore Floors. The ideal structural floor solution for all building types in all sectors. Hollowcore Floors Hollowcore Floors The ideal structural floor solution for all building types in all sectors. 2 3 System Overview Prestressed hollowcore units form part of the comprehensive range of precast

More information

AUGUST AUSTRALITE fire, acoustics & thermal technical manual

AUGUST AUSTRALITE fire, acoustics & thermal technical manual AUGUST 07 AUSTRALITE fire, acoustics & thermal technical manual AUSTRALITE CONTENTS Fire Resistance Levels / How to Use Structural Adequacy Charts / N-Loadbearing Structural Adequacy FRL s / 6 Loadbearing

More information

GIB Quiet Clip GIB CBI March Features and Benefits

GIB Quiet Clip GIB CBI March Features and Benefits CBI - 5113 March 2002 GIB Quiet Clip Features and Benefits No special flooring systems required Easy fit Installation Significantly improves low frequency sound transmission Significantly improves low

More information

Fire Resistant: Achieves FRL levels of 90/90/90 for load bearing walls.

Fire Resistant: Achieves FRL levels of 90/90/90 for load bearing walls. ( ) is a new and innovative system designed to provide high performance separating walls between units and apartments in low-rise residential and commercial projects. provides exceptional fire and acoustic

More information

Insulation options. Calculating U-Values

Insulation options. Calculating U-Values April 2017 Data Sheet 8 Aggregate concrete blocks External walls thermal performance Uniclass L3221 :A4 CI/SfB EPIC F611 :X221 Ff2 (Ajv) Concrete Block Association The Old Rectory, 8 Main Street, Glenfield

More information

ONE SCHOOL STREET SEPTEMBER 18, 2008 GOWANDA, NEW YORK ARCH PROJECT NO

ONE SCHOOL STREET SEPTEMBER 18, 2008 GOWANDA, NEW YORK ARCH PROJECT NO SECTION 09265 - GYPSUM BOARD SHAFT-WALL ASSEMBLIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

3.1 Noise Overlay District

3.1 Noise Overlay District 3.1 A. Purpose The purpose of this District is to establish a Noise Overlay Zoning District within the. B. Special Definitions As used in this Article only, the following terms shall be defined as set

More information