STANDARD TIMBER KIT SPECIFICATION
|
|
- Bethanie Mills
- 6 years ago
- Views:
Transcription
1 STANDARD TIMBER KIT SPECIFICATION Our specification provides a superior level of thermal efficiency and the insulation exceeds the requirements of the Scottish Building Standards Section 6 - Energy for the floor, walls and roof. Other important factors that impact on compliance to these requirements are the heating systems along with microrenewable technologies. We can assist you to achieve the most economical solution to this mandatory requirement info@ptarmiganhomes.com GROUND FLOOR Concrete ground floor construction Damp proof course Wallplate 0.16 W/m²K (or better) By others 150mm PVC DPC 45 x 145 treated whitewood EXTERNAL WALLS & GABLE SPANDREL 0.18 W/m²K Breather & thermal reflective Pre-fixed TF200 Thermo reflective membrane membrane Structural sheathing Pre-fixed 9mm OSB Structural framing Pre-fabricated 45 x 145 treated stress graded timber Headbinder Supplied loose 45 x 145 treated stress graded timber of walls Insulation to window/door ingos, head & beneath 12mm rigid insulation (0.022 W/m²K) cills Vapour control & thermal reflective membrane Reflectatherm foil & tape Service zone to internal face of walls Porch external finish Scottish Larch or White upvc horizontal cladding Window apertures 450mm PVC DPC MID FLOOR 1.5, 1.75 & 2.0 STOREY Flooring Mid floor construction 1.5 & 1.75 Storey Mid floor construction 2.0 Storey Acoustic insulation Insulation to integral garage ceiling to integral garage ceiling ROOF Tile battens 22mm V313 moisture resistant T&G chipboard flooring c/w screws & glue Formed by attic truss bottom chord 22mm JJI Engineered Midfloor System (Manufacturer Design) 100mm sound deadening roll (10kg/m³) 200mm Earthwool insulation (0.044 W/m²K) to ground floor ceiling (2 layers if attic trusses) 15mm fireline taper edged plasterboard to ground floor ceiling (2 layers if attic trusses) Tiles only - 25 x 50 treated whitewood (to suit 300mm centres)
2 Counter battens Tiles only - 12 x 38 treated whitewood Roof membrane Protect VP400 Structure Covering Tiles - 9mm OSB or Natural Slate - 22mm whitewood treated Sarking boards to suit roof covering Structure Prefabricated treated roof trusses, valleys, beams / (Manufacture to suit shipping restrictions) rafters and structural timbers to suit the roof design Bracing 22 x 100mm treated whitewood Gable ladders Prefabricated in sizes to suit roof design Fascia 18mm White upvc supplied in 5m lengths or 20mm treated redwood Eaves ventilation Over fascia strip ventilators Rafter ventilation proprietary eaves rafter vent/tray to maintain ventilation flow to loft space Bargeboard 18mm White upvc supplied in 5m lengths or 20mm treated redwood Soffit 9mm White upvc supplied in 5m lengths or 9mm WBP plywood Soffit framing 38 x 50 treated whitewood HORIZONTAL CEILINGS Insulation between & over ceiling ties COOMB CEILINGS 1.5 & 1.75 STOREY Rafters Insulation between rafters Vapour control & thermal reflective membrane Service zone HANGING POSTS 1.5 STOREY Insulation between hanging posts Vapour control & thermal Reflective membrane Service zone 0.11 W/m²K 400mm Earthwool insulation (0.044 W/m²K) 0.14 W/m²K minimum 47 x 197 treated stress graded timber 150mm rigid insulation (0.022 W/m²K) Reflectatherm foil & tape 0.19 W/m²K Reflectatherm foil & tape DORMER HAFFITS 1.5 & 1.75 STOREY 0.21 W/m²K External finish Scottish Larch or White upvc horizontal cladding Breather & thermal reflective Pre-fixed TF200 Thermo reflective membrane membrane Structural sheathing Pre-fixed 9mm OSB Structural framing re-fabricated 45 x 145 treated stress graded timber 100mm rigid insulation (0.022 W/m²K) Vapour control & thermal reflective membrane Reflectatherm foil & tape
3 INTERNAL WALLS Loadbearing partitions Pre-fabricated 45 x 95/145 treated stress graded timber Headbinder Supplied loose 45 x 95/145 treated stress graded timber Internal partitions Pre-fabricated 45 x 75 treated stress graded timber Acoustic insulation 25mm sound deadening roll (10kg/m³) GARAGE PARTY WALLS (where applicable) to garage side 15mm Fireline taper edged plasterboard Structural framing Pre-fabricated 45 X 145 treated stress graded timber Insulation to house side 25mm Rigid insulation (0.022 W/m²K) Vapour control & reflective thermal membrane Reflectatherm foil & tape Service zone to house side to house side GARAGE DOOR (where applicable) Up & over garage door Pedestrian Door Steel framed vertical lined door Factory finished white White upvc high performance door Low E toughened/laminate double glazing units ANCILLARY COMPONENTS / IRONMONGERY / FIXINGS Ancillary components 38 x 50 treated timber firestops 38 x 50 treated ceiling dwangs for plasterboard 22 x 100 treated service dwangs Treated timber flooring dwangs as required All required ironmongery/fixings for items listed Wallplate hammer fixings, galvanised holding down straps, stainless steel wall ties, truss clips, truss shoes, all necessary fixing nails, collated flooring screws and flooring glue, collated screws for plasterboard, staples for roofing membranes, Paslode gun nails/gas for kit erect including loose stitching nails and Paslode gun nails/gas for finishings, screws for fixing service zone battens WINDOWS & ROOFLIGHTS 1.40 W/m²K Windows (Secure by design) White upvc casement Low E double glazed windows (toughened/laminate & stippolyte obscure where required) Night vents as required Handles Supplied loose Brass or chrome Rooflights Velux rooflights complete with flashing kits to suit roof tiles EXTERNAL DOORS Front door (Secure by Design) 1.60 W/m²K Diamond DMM2 style composite door set with RG25 Linear decorative glass or equivalent
4 Brass or chrome letter plate and spy viewer fitted Back door (Secure by Design) Diamond DMG3 style white composite door set with SQL Square Lead decorative glass or equivalent Side Lights Diamond Composite or equivalent Low "E" clear/stippolyte backing double glazed units French/Patio doors (Secure by design) White upvc high performance door Low E toughened/laminate double glazing units (Restrictors and 2 handle operation to french doors only) Handles Supplied loose Brass or chrome FINISHING COMPONENTS Hinged door sets Prefabricated door sets c/w redwood frames & locks/latches installed (full depth door stops) Threshold plates Oak threshold plates Sliding door sets Doors as below with plates/thresholds to match the hinged door sets complete with sliding door gear all supplied loose Pass doors Primed white moulded smooth 990 doors or prefinished flush oak or equivalent Fire doors (FD30) Primed white moulded smooth 990 doors or prefinished flush oak or equivalent Glass doors Primed white moulded smooth 991 doors with clear flat glass or 15 glazed pane pine for staining or equivalent Cupboard doors To match pass doors Wardrobe doors To match pass doors (hinged/sliding) or sliding mirror wardrobe doors to suit floor plans Double doors Rebated with concealed slip bolts to slave leaf handles to each leaf Door handles Carlisle Calla, Oakley or Apollo style door handles supplied loose Door handle finish Brass or chrome Skirtings 95mm redwood or primed MDF (ogee/splayed/pencil round moulding) Facings 70mm redwood or primed MDF (ogee/splayed/pencil round moulding) Window cills Redwood or white primed MDF Window aprons Redwood or white primed MDF Stair Redwood stringer (Balustrading supplied loose) MDF treads/plywood risers Redwood stop chamfered newel posts c/w newel caps Redwood stop chamfered 41mm spindles Loft hatch Glidevale LA1 insulated push up loft hatch (0.77 W/m²K) Ancillary components Brass or Chrome wardrobe rails and support hangers
5 Ironmongery/fixings blockboard and sparred shelving hot water cylinder stool pipe box framing meter board All necessary nails and fixings including paslode gun nails/gas for finishings All structural timbers and roof trusses are pressure treated against rot and fungal attack. Supplied with each house kit is a complete set of kit erection drawings and a components checklist.
MATERIAL & COMPONENT SPECIFICATION DATE: 1 ST AUGUST 2018
SCANDIA-HUS FACT SHEET NO. 3 MATERIAL & COMPONENT SPECIFICATION DATE: 1 ST AUGUST 2018 THIS FACT SHEET SHOULD BE READ IN CONJUNCTION WITH OUR SHELL ERECTION SCHEDULE - FACT SHEET NO. 12 - WHICH CLEARLY
More informationMATERIAL & COMPONENT SPECIFICATION DATE: 1 ST JANUARY 2019
SCANDIA-HUS FACT SHEET NO. 3 MATERIAL & COMPONENT SPECIFICATION DATE: 1 ST JANUARY 2019 THIS FACT SHEET SHOULD BE READ IN CONJUNCTION WITH OUR SHELL ERECTION SCHEDULE - FACT SHEET NO. 12 - WHICH CLEARLY
More informationMATERIAL & COMPONENT SPECIFICATION DATE: 1 ST FEBRUARY 2015 ISSUE NO: 19
SCANDIA-HUS FACT SHEET NO. 4 MATERIAL & COMPONENT SPECIFICATION DATE: 1 ST FEBRUARY 2015 ISSUE NO: 19 THIS FACT SHEET SHOULD BE READ IN CONJUNCTION WITH OUR SHELL ERECTION SCHEDULE FACT SHEET NO. 13 -
More informationTYPICAL SCHEDULE OF COMPONENTS
TYPICAL SCHEDULE OF COMPONENTS ~ Site name ~ Detached 2 storey, 4 bedroom house with integral garage. Fully hipped roof, bedroom 1 to have a raised collar profile and hipped end. ~ 142 m2 gross Timber
More informationAffordable Quality - Easy Build. Building Specifications. Kitset Homes. latitudehomes.co.nz
Building Specifications Kitset Homes KITSET MATERIAL & SERVICE LIST (specifications are subject to change from time to time) PERMIT PLANS Permit Plans Ready to submit to local council based on information
More informationMr. A Sample Foxes Cottage Bolton Road Bury St Edmunds IP32 2DB 6th January 2014
Mr. A Sample Foxes Cottage Bolton Road Bury St Edmunds IP32 2DB TY MI PI NI CA AT L UR QU E OT SA AT MP IO N LE 6th January 2014 Dear Mr. A Sample, We are pleased to submit the following quotation as requested
More informationQuanti-Mate Professional Edition Material Estimation Software. Designed specifically for the Building Industry. Simplicity Itself.
Quanti-Mate Professional Edition Material Estimation Software. Designed specifically for the Building Industry. Simplicity Itself. Trewint, Main St, Shap, Cumbria, CA10 3NH. Contact Peter Ferguson on Tel
More informationTECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9
MARKINGWALLING OF SAFETY GLASS SPANDREL CURTAIN PANELS FORMED TO COLDFROM ROOFS STACKED WINDOW 7.2 /25 January ARRANGEMENTS (First Issue) XXXX EXXON QUESTION Which factors should be taken into account
More informationCustomer Specification
Customer Specification Hamilton Gardens, Elgin Plots 55-59, 87, 201-223 & 260-305 Page 1 Walls External walls will be of timber frame construction with external leaf of render block-work, or feature timber
More informationCustomer Specification
Customer Specification Hamilton Gardens, Elgin Plots 60-62 Page 1 Walls Timber frame construction with external leaf of render block-work. Timber studs with insulation and plasterboard finish internally.
More informationT I M B E R E N G I N E E R E D S O L U T I O N S
T I M B E R E N G I N E E R E D S O L U T I O N S self build background Frame UK established in 1974 have built an enviable reputation in the design, manufacture and construction of environmentally friendly
More informationSection 11 FIRE STOPPING
Section 11 This section highlights the key points relating to Fire Stopping. It is imperative that sites teams understand the importance of fire stopping and check it is completed correctly. It is to be
More informationSECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.
SECTION 06 1100 WOOD FRAMING PART 1 - GENERAL 1.1 SUMMARY A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But
More informationCustomer Specification
Customer Specification Dubford, Bridge of Don Houses & self-contained apartments Plots 107-129, 136-140, 226-231, 802-810, 1505-1522, 1607-1610, 1616-1618, 1621-1624, 1707, 1711-1714, 1717 & 1907-1908
More informationTIMBER BARNS AND GARAGES
CURRENT PRICE LIST TIMBER BARNS AND GARAGES TIMBER MINI BARNS Due to demand we offer some great value Mini Barns complete with stable fronts and partitions allowing you to work under cover at all times.
More informationEXW3 EXISTING DOWEL NEW FOOTING TO EXISTING WALL WITH 3-15M DOWELS, DOWEL THE NEW
-4 /4" 8" 4'-9 /" 6'-4" '-8" DEPRESS TO ACCOMODATE DOOR ABOVE DOWEL NEW FOOTING TO WITH 3-5M DOWELS, DOWEL THE NEW S TO THE S WITH 5M @ 4" O.C. VERTICALLY, PROVIDE -5M BARS 6" LONG IN THE FOOTING 4'-9"
More informationGuidance on U Values from Domestic Heating Design Guide
Guidance on U Values from Domestic Heating Design Guide The following U Values are from the Domestic Heating Design Guide, and the complete publication is available for purchase from members of the Domestic
More informationSelecting floors and ceilings
floors and ceilings email: bgtechnical.enquiries@bpb.com www.british-gypsum.com/health 89 floors and ceilings Introduction 9 Solutions - key systems 9 Solutions for concrete floors 9 - Dense slab 9 This
More informationBuilding Regulations for the Conservation of Fuel and Power
Insulation Second Issue (b) December 2012 Building Regulations for the Conservation of Fuel and Power EXISTING DWELLINGS 2010 Health Check Low Energy Low Carbon Buildings Contents Page Introduction 3 Approved
More informationRange Guide. Design Options in PVC Roofline and Cladding. The Specifier s Choice for Cellular PVC Roofline & Cladding BBA BRITISH BUILDING PRODUCTS
Uniclass L5:P7113 CI/SfB (4-) Hn7 10.08 Range Guide Design Options in PVC Roofline and Cladding BBA BRITISH BOARD OF AGRÉMENT CERTIFICATE NO.91/2620 CERTIFICATE NO.91/2622 BS 7619 Licence No. KM33730 FM
More informationCASE 1 : SINGLE FAMILY HOUSE. VIA / TCU 3rd semester workshop A2015. Building. Component Technical Course. VIA/ TCU workshop A2015
VIA / TCU 3rd semester workshop A2015 Building CASE 1 : SINGLE FAMILY HOUSE Component Technical Course VIA/ TCU workshop A2015 1 Aim of the Course: Discovery of Building component in Denmark & China Understanding
More informationConstruction details:
Extension Specifications, 23 Nightingale Avenue Floor area (internal): 27.6m 2 Gross floor area: 31.9m 2 Construction details: Walls Construction from inside: (Option A) wet plaster (airtightness layer
More informationCarpenter Level 2 Rev. September 2017
Level 2 A5 Site Layout II Duration: 14 hours 7 hours 7 hours Upon completion of this unit the apprentice will demonstrate knowledge of site layout tools and equipment and their applications and procedures
More informationDRY CONSTRUCTION SYSTEMS
DRY CONSTRUCTION SYSTEMS Adrienn LEPEL BUTE Dry construction systems Prefabricated elements assembly on site Minimal use of water dry construction systems Assembled partitions Suspended ceilings Raised
More informationSECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.
SECTION 06110 WOOD FRAMING PART 1 GENERAL 1.1 SUMMARY A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But Not Supplied
More informationWall lining Inner leaf blockwork. K106 Cavity Board. Flexible sealant STANDARD DETAILS FOR 115 MM INSULATION BOARD IN A 125 MM CAVITY
Insulation CI/SfB (21.9) Rn7 M2 First Issue May 2017 oltherm Board rick outer leaf d retaining clip amp proof course om K106 Cavity Board y fill K106 Cavity Board STANDARD DETAILS FOR 115 MM INSULATION
More informationPROJECT IDEA CATALOG. FREE! Take one. Get inspired! 84LUMBER.COM
PROJECT IDEA CATALOG FREE! Take one. Get inspired! 84LUMBER.COM Gambrel Barns These oversized barns maximize your storage space. They re easy to build, using our engineered truss brackets, providing a
More informationThe Celotex Handy Guide
The Celotex Handy Guide celotex.co.uk When you choose Celotex, you re choosing a unique level of service, support and online tools. In fact, some of that support is in your hands right now. This little
More informationCarroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage
Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage The following list of code requirements is intended to assist you in complying with the Code of Public
More informationApartments. for. Mr. Client. at: London
Apartments for Mr. Client at: London Mr. Client Site address: London 28 June 2013 Dear Mr. Client, Subject: Apartments Thank you for your valued enquiry and instructions to quote for the above project.
More informationSection B Detailed Draw ings
Section Detailed Draw ings b 1 cut roofs 139 b.1.1 Stability and load transfer 139 b 1.2 rafter details 139 b 1.3 purlin details 140 b 1.4 water cistern support 141 b 2 trussed rafter roofs 145 b 2.1 general
More informationBuilding Specifications
Building Specifications NZB60 Wairoa NZB70 Motu NZB80 Akaroa NZB90 Te Mata NZB100 Waiheke NZB105 Waipa NZB112 Tamaki NZB140 Fox NZB153 Tekapo NZB180 Kaikoura NZB200 Buller NZB220 Milford latitudehomes.co.nz
More informationHomeowners complain about having too much storage space about as often as they do about having an overabundance of cash. It just doesn't happen.
Homeowners complain about having too much storage space about as often as they do about having an overabundance of cash. It just doesn't happen. Nearly every home, regardless of its size, has a shortage
More informationCarpentry. The following describes the scope and sequence of instruction for Carpentry.
Carpentry The Montgomery County Students Construction Trades Foundation, Inc has developed a comprehensive construction technology program designed to prepare students for a rewarding career in the construction
More informationCalculated Quantities and Details
Estimate # 8/14/2007 Estimate For: Bill Johnston Finest Quality Homes 1234 Heght Blvd #204 Houston Tx 77079- Ph: (281) 555-5555 Fax: (281) 555-5556 P.O. Box 323 Simonton Tx. 77476 Phone: (281) 346-2462
More informationEnergy Panel Structures, Inc
Energy Panel Structures, Inc. 712-859-3219 www.epsbuildings.com 1. General Information The information provided in this manual is to be used as a general guide. Refer to detailed drawings provided by EPS
More informationThis document has been prepared to assist in the preparation of construction certificate plans and specifications in respect to BAL 12.5.
ABN 26 807 194 868 Suite 1 146 Oak Road KIRRAWEE NSW Phone 8880 4480 Email: info@mybuildingcertifier.com.au Construction Standards to Comply with Australian Standard 3959 2009 & Appendix 3 of Planning
More informationNo 18 DIAMOND GARDENS Finaghy, Belfast BT10 0HE
No 18 DIAMOND GARDENS Finaghy, Belfast BT10 0HE This most attractive pre 1945 semi detached home with modern matching detached garage and private gardens is well situated in a highly regarded residential
More informationPRELIMINARIES / GENERAL conditions
24 Pages Close, Histon PC AND PROVISIONAL SUMS PRELIMINARIES / GENERAL conditions A54: PROVISIONAL WORK Include the following Provisional Sums:- For defined work A work to existing adjoining flat roof
More informationTW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork
Insulation CI/SfB (21.9) Rn7 M2 First Issue May 2017 e with retaining clip TW50 STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY 25 mm / 50 mm residual cavity Kingspan Thermawall TW50 Outer
More informationMetal Web Floor System
Metal Web Floor System Contents Contents Introduction and benefits 3 easi-joist definitions 4 easi-joist webs 5-6 Mechanical services 7 Loading and design 8 Floor stiffness 9 Internal non-loadbearing wall
More informationLP SMARTSIDE P R I C E L I S T* *Prices effective January 2019 and subject to change
LP SMARTSIDE P R I C E L I S T* *Prices effective January 2019 and subject to change www.barnraisersheds.com WITHIN 30 MILES ON MOST STRUCTURES! Some photos shown with Mini Barn High Wall Barn Super Barn
More informationGARAGE MAIN FLOOR PLAN
12'-0" 4'-6" 3'-0" 4'-6" 3040 14'-0" LADDER LT LINE BUNK CABIN 11'-4" x 13'-4" 14'-0" BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS.
More informationRefurbishment site guidance for solid-walled houses ground floors
GOOD PRACTICE GUIDE 294 Refurbishment site guidance for solid-walled houses ground floors What energy savings to aim for Key points to consider Energy savings and SAP ratings Environmental considerations
More informationB and H Cedar Log Homes, L.L.C. 65 Nottingham Dr.
Page:1 Sandy's Joy - List of materials needed to construct a weather tight home. Additional materials needed to complete the rough-in framing are also listed. PLEASE NOTE: 1. 'While every attempt has been
More informationURSA TF Roll URSA GLASSWOOL.
URSA GLASSWOOL E-mail : ursauk@uralita.com URSA UK LTD Crest House 102-104 Church Road Teddington, Middlesex TW11 8PY United Kingdom Tel : 020 8977 96 97 Fax : 020 8977 94 56 Web : www.ursa-uk.co.uk E-mail
More informationAffordable Quality - Easy Build. Building Specifications. Full Build Homes. latitudehomes.co.nz
Building Specifications Full Build Homes FULL BUILD SERVICE MATERIAL & SERVICE LIST (specifications are subject to change from time to time) FOUNDATIONS Engineer designed concrete floor to NZ Building
More informationPROPOSED ERECTION AND COMPLETION OF CEREAL STORE.
PROPOSED ERECTION AND COMPLETION OF. AB/1 STORE ELEMENT NO. 1 A B SUBSTRUCTURES (ALL PROVISIONAL) Excavations Clear site of small bushes and grub roots of small trees and cart away Excavate average 150mm
More informationANNEXURE B SECTION 1
ANNEXURE B SECTION 1 HOUSING SPECIFICATIONS 1. Houses 1.1. Roofs Material: Architect approved concrete tiles @ 17,5 degree pitch on SABS approved underlay Colour: As per Architects. 1.2. Rainwater goods
More informationLP SMARTSIDE P R I C E L I S T* *Prices effective January 1st 2018 and subject to change
Some Photos Shown With Options Mini Barn High Wall Barn Super Barn Workshop Workshop Quaker A- Frame Super Barn 4' Wall (Dutch Barn) 6' Wall 7½' Wall Garage Garage 6 x 6 - - - - - - - - 6 x 8 1795 - -
More information206 Basic Construction Management
7024_CH13_APP2.QXP_pz 10/23/08 10:13 AM Page 206 206 Basic Construction Management Framing Trade Contractor Job Name, Number Pass/Fail/NA All work complies with locally adopted codes and International
More informationTYPICAL QUOTATION MINIATURE SAMPLE
Client Documents Mr. A Sample Foxes Cottage Bolton Road Bury St Edmunds IP DB Dear Mr. A Sample, We are pleased to submit the following quotation as requested for works to be carried out at Foxes Cottage,
More informationPRELIMINARY INSPECTION FRAMEWORK
PRELIMINARY INSPECTION FRAMEWORK 1. Oversite Striping of topsoil Forming site entrance Clearing off topsoil for service roadway Roadside drainage continued under entrance bay Any mature trees in vicinity
More informationGypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.
GypLyner GypLyner Metal framed wall lining system All our systems are covered by SpecSure when using genuine Gyproc and Isover products Linings GypLyner GypLyner is a cost-effective, virtually independent
More informationCI/SfB (37.5) Xn6 Uniclass L416 May LOFT ACCESS TRAPS ...
...... CI/SfB (37.5) Xn6 Uniclass L416 May 2002 ...... The new 2002 energy conservation requirements of Approved Documents L1 and L2 mean that a loft trap needs to be a highperformance product. Site-constructed
More informationGAF EnergyGuard Polyiso Wall Sheathing
From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include:
More informationIntroduction to timber frame construction
CI/SfB 81 (2.2) Yi Uniclass JB1 : JG2 Wood Information Sheet WIS 0-3 Subject: Timber frame Reviewed: April 2016 with minor corrections Introduction to timber frame construction Modern methods of timber
More informationMAIN FLOOR PLAN. #G x 14 x 8 Shed - Chicken Coop By SDS-CAD Specialized Design Systems 10'-0" 3'-0" 1'-0" 14'-0" 14'-0" 1'-0" 6'-0" 3'-0"
10'-0" BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. BARN TO BE BUILT AS PER LOCAL CODE REQUIREMENTS 14'-0" BWP BWP BWP ABWP 101
More informationContents P/ 3. Ensuring Optimal Results P/ 4. Roof Insulation SF40 P/ 5. Roof Insulation Over Rafter Application P/ 6
Installation Guide Contents P/ 3 Ensuring Optimal Results P/ 4 Roof Insulation SF40 P/ 5 Roof Insulation Over Rafter Application P/ 6 Roof Insulation Under Rafter Application P/ 7 Roof Insulation Duet
More informationChapter 32 - Garage. June 2015 Garages 32-1
Chapter 32 - Garage Contents Chapter 32 - Garage... 32-1 Foundation... 32-3 Walls... 32-3 Roof Framing... 32-4 Roofing... 32-4 Exterior Dow Board... 32-5 Doors... 32-5 Siding... 32-5 Gutters... 32-6 Painting...
More informationLonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)
Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN 55046 (507) 744-2327 fax (507) 744-5554 2006 RESIDENTIAL CONSTRUCTION CHECKLIST The following checklist has been designed
More informationSTRUCTURAL TIMBER ASSOCIATION
Version 2.0 - August 2016 STRUCTURAL TIMBER ASSOCIATION Building solutions in timber Delivering building control through local authorities Technical support for the STA pocket guide kindly provided by
More informationOverview. Dimensions
Overview Completed for (inc. VAT, delivery and installation) This project includes a treehouse on a raised platform and three additional raised platforms with a variety of access points to ensure that
More informationConcrete Soffit Direct Fix
Installation Guide Concrete Soffit Direct Fix Recommended Pattern insulation boards may be installed in any pattern. The recommended pattern is a square-set pattern, for simplest and quickest configuration
More informationQUALITY GARDEN BUILDINGS. Bespoke Cedar Garden Rooms and Offices HANDMADE IN WORCESTERSHIRE FOR OVER 40 YEARS
QUALITY GARDEN BUILDINGS Bespoke Cedar Garden Rooms and Offices HANDMADE IN WORCESTERSHIRE FOR OVER 40 YEARS Welcome to The Malvern Collection Handmade Quality Garden Buildings for over 40 years The company
More informationSIDE ELEVATION AS PROPOSED (SOUTH)
Existing cladding to be replaced under permitted development SIDE EXTENSION SIDE EXTENSION Vertical timber cladding to match the existing house Existing slatted fence on boudary REAR ELEVATION AS PROPOSED
More informationPart 6 Superstructure (excluding roofs) Chapter 6.2. External timber framed walls
Part 6 Superstructure (excluding roofs) Chapter External timber d walls External timber d walls CONTENTS SCOPE DESIGN Clause Page Design standards D1 1 Statutory requirements D2 1 Load bearing walls D3
More informationTRISO-SUPER 10 INSTALLATION GUIDELINES
2009 Edition ACTIS THIN MULTIFOIL INSULATION INSTALLATION GUIDELINES ROOFS ATTICS EUROPEAN TECHNICAL APPROVAL IN PROCESS Registration N 12.01/12 2 Contents Technical characteristics 2 Essential rules of
More informationThe Earth Friendly Board
VIVA CEMENT BOARD The Earth Friendly Board VIVA WOOD CEMENT BOARD is manufactured from wood, cement and mineralising agent. The combination of these raw materials resulted in a board with unique properties
More informationV1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide
V1/0715/AI/TDO1 KORE Loft Insulated Flooring System Design Guide KORE Loft Insulated Flooring System Key Features Excellent thermal performance for the lifetime of the building Sheets tongue and grooved
More informationCI/Sfb (2 ) Rn7 M2 Fourth Issue June Product Selector INSULATION FOR ROOFS, WALLS & FLOORS. Low Energy Low Carbon Buildings
Insulation CI/Sfb (2 ) Rn7 M2 Fourth Issue June 2011 Product Selector INSULATION FOR ROOFS, WALLS & FLOORS Visit our brand new website: www.kingspaninsulation.co.uk Low Energy Low Carbon Buildings Kingspan
More informationGARAGE MAIN FLOOR PLAN
BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. SHED TO BE BUILT AS PER IRC, UBC OR CURRENT LOCAL CODE To the best of my knowledge
More informationChapter 7. Roof Framing
Chapter 7. Roof Framing 7.1 ROOFING PREP WORK 7.2 INSTALLING ROOF TRUSSES 7.3 INSTALLING PORCH TRUSSES 7.4 SHEATHING ROOF 7.5 INSTALLING SUB-FASCIA 7.6 BUILDING AND INSTALLING SCUTTLE BOX 7.7 INSTALLING
More informationTOFT HOUSE, THRESHFIELD Heritage Statement Feature: Window frames in South Elevation - windows 5,6,7,12,13 Description Softwood painted casements with side hung opening lights. Single glazed. Simply constructed
More informationfire, thermal & acoustic insulation
fire, thermal & acoustic insulation PRODUCT BROCHURE INTRODUCTION With over 45 years experience in insulation conversion, Mayplas is a market-leading manufacturer of fire stopping, thermal and acoustic
More information2003 International Residential Building Code
2003 International Residential Building Code Section R305 Ceiling Height Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less
More informationGAZEBOS GARAGES CAR PORTS OUT BUILDINGS
GAZEBOS GARAGES CAR PORTS OUT BUILDINGS Timeless Buildings is a division of BSW Timber Group, the most technically advanced and progressive sawmilling company in the UK. We have the latest techniques to
More information(Text with EEA relevance) (2017/C 10/02)
C 10/2 EN Official Journal of the European Union 13.1.2017 Commission communication in the framework of the implementation of Regulation (EU) No 305/2011 of the European Parliament and of the Council laying
More informationNew versatile and effective dry fix solutions for the roofline and above
Cavity trays Access panels Loft access doors Gas barrier and damp proofing accessories Under floor and through wall ventilation Cavity closers and stops Air leakage solutions New versatile and effective
More informationThe Homeowner s Building Application Checklist for Constructing a Residential Addition
The Homeowner s Building Application Checklist for Constructing a Residential Addition This checklist provides homeowners a summary of the Building Permit submission requirements for constructing a residential
More informationThe Total Service. Scotts of Thrapston is one of the country s leading suppliers of specialist timber products for the construction industry.
Roof Structures The Total Service Scotts of Thrapston is one of the country s leading suppliers of specialist timber products for the construction industry. As a leading member of the Trussed Rafter Association,
More informationFOREST PLACE 59 UNITS ERF 5586 PARKLANDS
ANNEXURE "C" MATERIAL AND FINISHES SPECIFICATION FOREST PLACE 59 UNITS ERF 5586 PARKLANDS 1. FOUNDATIONS AND STRUCTURE Foundation walls are to be built in strict accordance with the municipal building
More informationLABC REGISTERED THERMAL SYSTEMS TO PART L
LABC REGISTERED THERMAL SYSTEMS TO PART L 2006 AND 2010 MULTI-FOIL INSULATION AND BREATHER MEMBRANES Contents 1 Foreword...4 2 How TLX Multi-foils Work...5 3 The TLX Range...6 4 U Values and Condensation
More informationButte County Fire Department Fire Prevention Bureau 176 Nelson Avenue Oroville, CA Office (530)
2016 CBC Chapter 7A and CRC Section R337 (The use of paints, coatings, stains, or other surface treatments are not an approved method of protection as required in this chapter.) The Wildland Urban Interface
More informationLUXURY LOG CABINS. Built under caravan regulations act 1960, 1968 Amendment 2006 BS VAT Zero rated 701/20
CARPENTRY & CONSTRUCTION LUXURY LOG CABINS Built under caravan regulations act 1960, 1968 Amendment 2006 BS 3632-2005 VAT Zero rated 701/20 Building Regulation 2010 Intro All the cabins built by PG Carpentry
More informationBILLS OF QUANTITIES FOR CONSTRUCTION OF MODEL DISPENSARY BLOCK AT MGUNGANI / SALAITA
BILLS OF QUANTITIES FOR CONSTRUCTION OF MODEL DISPENSARY BLOCK AT MGUNGANI / SALAITA CONSTRUCTION OF MODEL DISPENSARY BLOCK Item DESCRIPTION QTY UNIT RATE TOTAL(KS ELEMENT : SUBSTRUCTURE (ALL PROVISIONAL):
More informationTYPICAL DETAILS MANUAL
TYPICAL ETAILS MANUAL ETAIL LIST AN ESCRIPTION ETAIL LIST RAWING NUMBER ETAIL NUMBER ETAIL ESCRIPTION ISION 01 ETAIL LIST 101 etail 101 Concrete Slab Edge etailing 102 etail 102 Concrete Set own etailing
More informationLABC RegisteRed thermal systems to PARt L 2006 And 2010 multi-foil insulation And BReAtheR membranes
LABC Registered Thermal Systems to Part L 2006 and 2010 multi-foil insulation and breather membranes Contents 1 Foreword...4 2 How TLX Multi-foils Work...5 3 The TLX Range...6 4 U Values and Condensation
More informationJune Residential New Build Timber Frame Walls
June 2010 Residential New Build 2.5.2 Timber Frame Walls Residential new build 2.0 Residential New Build Timber Frame Walls Contents Introduction find online page Solution optimiser and pathfinder 186
More information20 THINGS YOU NEED TO KNOW ABOUT LOFT CONVERSIONS
01 IS THERE A MINIMUM HEADROOM REQUIREMENT TO THE NEW LOFT ROOM? Not to the room itself, although of course you need to be able to use the space. However, the new stairs will need a minimum 2.0m clear
More informationRefurbishment site guidance for solid-walled houses windows and doors
GOOD PRACTICE GUIDE 295 Refurbishment site guidance for solid-walled houses windows and doors What energy savings to aim for Key points to consider Energy savings and SAP ratings Environmental considerations
More informationPAGE 415. Part 9. External works. 9.1 Garages. 9.2 Drives, paths and landscaping
PAGE 415 Part 9 External works 9.2 Drives, paths and landscaping Part 9 External works Chapter CONTENTS SCOPE Clause DESIGN Design standards D1 1 Statutory requirements D2 1 Garage foundations D3 1 Garage
More informationNEWS LETTER MARCH 27, 2009
PLANNING, BUILDING & DEVELOPMENT SERVICES DEPARTMENT 580-1 Street S.E. Medicine Hat, Alberta T1A 8E6 Telephone: 529-8374 FAX 502-8038 1 NEWS LETTER MARCH 27, 2009 GENERAL As you are probably aware there
More informationPORCH PLAN. Existing House. New Porch. Page A.1. Boxed Beams. 5/4x6 Cedar Decking. Roof Overhang. Wood Columns. Hip Roof. Step
Porch Plan 28 68 2'-0" 7'-8" 2'-0" 7'-0" PORCH PLAN SCALE: /4" = '-0" CD24 0 SECT D A.6 7 /4" 7 /4" Boxed Beams Existing House 23'-2 /4" 30 68 New Porch Step Wood Columns 8'-0" 2'-0 /2" 2'-0 /2" 8'-0"
More informationTHE FLORIDA BUILDING CODE
THE FLORIDA BUILDING CODE 1. According to the Florida Building Code, spiral stairway treads must all be identical and rise must be sufficient enough to provide a headroom of minimum. A. 6'- 4" B. 6'- 6"
More informationBISHOP GARAGE Specifications & Construction Details
BISHOP GARAGE Specifications & Construction Details TABLE OF CONTENTS Introduction 3 1 Material Specification Charts 4 2 Dimensions 21 Elevations 22 Plan (Footprint) 5 6 3 Construction Details 31 Foundations
More informationARCHER GARAGE Specifications & Construction Details
ARCHER GARAGE Specifications & Construction Details TABLE OF CONTENTS Introduction 3 1 Material Specification Charts 4 2 Dimensions 21 Elevations 22 Plan (Footprint) 5 6 3 Construction Details 31 Foundations
More informationCARPENTRY TRADE SPECIFICATION
CARPENTRY TRADE SPECIFICATION GENERAL a) BDW Trading Limited Barratt Homes and David Wilson Homes are all trading names of BDW Trading Limited the Company. b) Clearing Contractor is responsible for clearing
More informationDoc Ref: AT_CHECKLIST Title: Residential Air Permeability Checklist Issue: V4
Doc Ref: AT_CHECKLIST Title: Residential Air Permeability Checklist Issue: V4 Please tape all ventilation within the build; this will enable the engineer adequate time onsite to assist in any small remediation
More informationA Handbook of thermal bridging details incorporating aircrete blocks
A Handbook of thermal bridging details incorporating aircrete blocks Book 2 Thermal bridging solutions for external wall full fill cavity details Prepared for the Aircrete Products Association by the BBA
More information