Effect of Built-Form Configuration on Energy and Structural Performance of Skyscraper Buildings

Size: px
Start display at page:

Download "Effect of Built-Form Configuration on Energy and Structural Performance of Skyscraper Buildings"

Transcription

1 April 2-4, 2012 Effect of Built-Form Configuration on Energ and Structural Performance of Skscraper Buildings Mohamed Krem Dr. Simi Hoque Dr. Sanja R. Arwade Universit of Massachusetts Amherst (UMASS) 1

2 Global Population and Tall Building Council on Tall Buildings and Urban Habitat (CTBUH),2011 ; An Analsis of Global Population and Tall Building 2

3 Council on Tall Buildings and Urban Habitat (CTBUH),2011 ; An Analsis of Global Population and Tall Building 3

4 In the US Buildings account for almost 40% of all energ use 68 % of the electricit energ 33 %of the total energ are used to heat, cool, and operate buildings Results Current global energ crisis Non-renewable sources of energ Decreasing the sustainabilit 4

5 Solution Tall and Green Buildings Green Buildings ma be defined as buildings must meet the needs of the present generations without compromising the abilit of future generations to meet their needs as well (brundtland commission) Future Generations compatibilit between the The building Green building components and the environment. Once building construction ends, it becomes a part of its environment, like a tree or stone, and is eposed to the effects of the sun, wind, and rain. If the building is designed with these different environmental conditions in mind, it ma take advantage of available solar or 5

6 Problem statement Building morphologies Energ performance How these three parameters are related to each other. Structural performance 6

7 An Approach It is been suggested that Using the structural sstem of a building to improve energ efficienc in addition to resisting gravit and lateral loads Yeang [The Green Skscraper]. Central Edge Half Sides Sides core wall N Climate Cool Temperate Arid Tropical Aspect ratio Y:X 1:1 1:1.6 1:2 1:3 7

8 e Schematic deformation mode Central Edge Half Sides Sides core Wind pressure P R e P T T R T T Central e= 0 Edge e= 20.3 m Half sides e= 9.18 m Sides e= 0 : Centroid : Center of rigidit e: Eccentricit R: Rotation T: Translation 8

9 Agenda Energ performance Energ demand Operational energ cost Structural performance Structural analsis Material quantities Total Cost Envelope stud Equivalent percentages of opaque surfaces(epo) Update total cost Conclusions /07-01c.jpg 9

10 Energ analsis 10

11 36.75 m 13.5 m 18.4 m 8 m 22 m 21 m 12.6 m 4 m 30 m 41 m 20.5 m 15 m 10.5 m 17 m 1 1 Central Ecotect models Edge 20 m 14 m 20 m 18 m 8 m 19 m 21 m m m Plan view -central configuration [ 100% glazing] Plan view -edge configuration [31% opaque ; 69% glazing] Half Sides Sides 23 m 20 m 28 m 18 m 34 m 28 m 15.6 m 23 m 90 m m Plan view -half sidrs configuration [17% opaque ; 83% glazing] Elevation Plan view -sides configuration [25% opaque ; 75% glazing]

12 Ecotect Analsis : is a comprehensive conceptto-detail sustainable building design tool, with a wide range of simulation and building energ analsis functionalit. Input Building geometr in 3D Building location and orientation Building material use Thermal resistance (Rvalue) for the building s envelope (According to IECC 2009) Thermal analsis conditions Thermal Analsis 12 Output Annual heating/ cooling loads Others

13 Thermal analsis results Tpe Climate Central Edge Half sides Sides % Difference [between Energ Use Intensit (kwh/m 2 ) Energ Use Intensit (kwh/m 2 ) Energ Use Intensit (kwh/m 2 ) Energ Use Intensit (kwh/m 2 ) lowest EUI and highest EUI] Cool % Temperate % Arid % Tropical % 13

14 Operational energ cost of 50 ears life span 14

15 Trade-off Now, we need to know whether the trade-off of placing the structural walls to maimize operating energ efficienc will not cause the total cost to be too great 15

16 Variables Structural wall placements Building shape Supplementar lateral load resistance sstem(sllr) Structural Analsis Output Lateral displacements Amount of Materials used Embodied energ Material used cost 16

17 Structural Analsis 17

18 Structural Analsis 18

19 Structural Analsis 19

20 Configurations Sides Half Sides Edge Central Structural Analsis Results Maimum displacement service wind load P w and 0.75 P w With SLLR - strength checked With SLLRserviceabilit checked Maimum displacement service wind load P w and 0.75 P w With SLLR - strength checked With SLLRserviceabilit checked Serviceabilit threshold (m) (ASCE 7-10) U (m) U (m) SLLR: supplementar lateral load resistance sstem 20

21 configuration Embodied energ of the material used (for BSS & SLLR) Material quantit Steel (t) From SLLR concrete (t) From BSS Embodied energ GJ/t SLLR Steel BSS Concrete Normalized Embodied energ SLLR Steel BSS Concrete Total Central Edge Half Sides Sides The embodied energ is normalized with respect to material embodied energ (BSS) in the Sides configuration. SLLR: supplementar lateral load resistance sstem BSS: base structural sstem 21

22 Total material used cost inde Material quantities Normalized cost configuration Steel (t) From SLLR concrete (m 3 ) From BSS Total material (BSS+SLLR) Central Edge Half Sides Sides The cost is normalized with respect to material cost in the Sides configuration. SLLR: supplementar lateral load resistance sstem BSS: base structural sstem 22

23 Total cost of 50 ears life span 23

24 Edge configuration Envelope stud Half Sidrs configuration 20 m 18 m 17 m m 18.4 m 20 m 12.5 m 41 m 20.5 m 19 m 21 m m 28 m 15.6 m 23 m m m 31% Structural walls (Mass material) 10% framing of 69% glazing walls opaque surfaces 17% Structural walls (Mass material) 10% framing of 65.5% glazing walls % curtain walls opaque surfaces Central configuration m Sides configuration m 20 m 21 m 14 m 15 m 23 m 1.5 m m 30 m 28 m 18 m 34 m m 21 m 90 m 10% framing of 69% glazing walls 31% curtain walls opaque surfaces 25% Structural walls (Mass material) 10% framing of 69.5% glazing walls 5.95% curtain walls opaque surfaces Structural walls : Glazing walls curtain walls 24

25 Results of EPO Climate Envelope Central Edge Half sides Sides EUI ( kwh/m2) Cool Temperate Arid Tropical Initial EPO Initial EPO Initial EPO Initial EPO EUI: Energ Use Intensit EPO: Equivalent Percentages of Opaque surfaces 25

26 Total cost of 50 ears life span 26

27 Conclusions 27

28 Conclusions 1- Building morphologies (footprint shape and the placement of structural vertical core/walls) significantl influences overall energ performance. N Climate Cool Temperate Arid Tropical Aspect ratio Y:X 1:1 1:1.6 1:2 1:3 28

29 2- The structural Conclusions vertical walls in the east and west sides and with an aspect ratio of 1:3, ma lead to a reduction in energ consumption of 5% to 32%, depending on the climatic zone. wall 29

30 Conclusions 3- Significant improvement in energ performance can be gained b adding opaque surfaces in the Central configuration envelope (reduction in energ consumption of 7% to 37%) depending on the climatic zone N 30

31 Conclusions 4- The trade-off of placing the structural walls to maimize operating energ efficienc is too great. The potential irregularit in the rigidit, caused a substantial growth cost (about 40% more than normal cases) in materials that reflected negativel on the total cost. 31

32 Man Thanks 32

Quantifying the impact of passive design on high rise buildings

Quantifying the impact of passive design on high rise buildings Quantifying the impact of passive design on high rise buildings Mohamed A. M. Krem 1, Simi T. Hoque 2,Sanjay R. Arwade 3 1 Department of Civil Engineering, Al-Mergeb University, Al-Khoms, Libya 2 Department

More information

Collapse Simulation for a Super-Tall Mega-braced Frame Core-tube Building

Collapse Simulation for a Super-Tall Mega-braced Frame Core-tube Building Collapse Simulation for a Super-Tall Mega-braced Frame Core-tube Building W.K. Zhang, X. Lu, X.Z. Lu, L.P. Ye & J.R. Qian Department of Civil Engineering, China Ke Laborator of Civil Engineering Safet

More information

DESIGN, SIMULATION AND ANALYSIS OF A HYBRID-TYPE (PV/T) SOLAR AIR HEATER FOR HIGH PERFORMANCE

DESIGN, SIMULATION AND ANALYSIS OF A HYBRID-TYPE (PV/T) SOLAR AIR HEATER FOR HIGH PERFORMANCE DESIGN, SIMULATION AND ANALYSIS OF A HYBRID-TYPE (PV/T SOLAR AIR HEATER FOR HIGH PERFORMANCE Pramod kumar N Research Scholar, Department of Mechanical Engineering, VVCE, Msuru B. Sadashive Gowda Principal,

More information

MODELING STRATEGIES FOR THREE DIMENSIONAL ANALYSIS OF PRECAST PANEL BUILDINGS UNDER SEISMIC LOAD

MODELING STRATEGIES FOR THREE DIMENSIONAL ANALYSIS OF PRECAST PANEL BUILDINGS UNDER SEISMIC LOAD MODELING STRATEGIES FOR THREE DIMENSIONAL ANALYSIS OF PRECAST PANEL BUILDINGS UNDER SEISMIC LOAD Serdar ASTARLIOGLU, Ali M MEMARI And Andrew SCANLON SUMMARY This paper describes a computer program (SNAPS-D)

More information

I. SOURCE AND APPLICABILITY

I. SOURCE AND APPLICABILITY Draft revision to the approved consolidated baseline and monitoring methodolog ACM0006 Consolidated methodolog electricit generation from biomass residues I. SOURCE AND APPLICABILITY Sources This consolidated

More information

CDM Meth Panel AM00XX / Version 01 Sectoral Scope: XX 24 October Draft baseline methodology AM00XX

CDM Meth Panel AM00XX / Version 01 Sectoral Scope: XX 24 October Draft baseline methodology AM00XX Sources Draft baseline methodolog AM00XX Baseline methodolog for conversion from single ccle to combined ccle power generation This baseline methodolog is based on elements from the following methodologies:

More information

I. SOURCE AND APPLICABILITY Sources This consolidated methodology is based on elements from the following methodologies:

I. SOURCE AND APPLICABILITY Sources This consolidated methodology is based on elements from the following methodologies: Draft revision to the approved consolidated baseline and monitoring methodolog ACM0006 Consolidated methodolog for electricit generation from biomass residues in power and heat plants I. SOURCE AND APPLICABILITY

More information

Revision to the approved consolidated baseline methodology ACM0001. Consolidated baseline methodology for landfill gas project activities

Revision to the approved consolidated baseline methodology ACM0001. Consolidated baseline methodology for landfill gas project activities Sources Revision to the approved consolidated baseline methodolog ACM0001 Consolidated baseline methodolog for landfill gas project activities This methodolog is based on elements from the following approved

More information

Indicative simplified baseline and monitoring methodologies for selected small-scale CDM project activity categories

Indicative simplified baseline and monitoring methodologies for selected small-scale CDM project activity categories TYPE I - RENEWABLE ENERGY PROJECTS Project participants shall appl the general guidance to the small-scale CDM methodologies, information on additionalit (attachment A to appendix B) and general guidance

More information

SEISMIC DESIGN AND NUMERICAL VALIDATION OF POST-TENSIONED TIMBER FRAMES

SEISMIC DESIGN AND NUMERICAL VALIDATION OF POST-TENSIONED TIMBER FRAMES The th World Conference on Earthquake Engineering October -7, 8, Beijing, China SEISMIC DESIGN AND NUMERICAL VALIDATION OF POST-TENSIONED TIMBER FRAMES M.P. Newcombe, S. Pampanin, A. Buchanan and A. Palermo

More information

Chapel House- Design Process- Envelope and Energy savings

Chapel House- Design Process- Envelope and Energy savings Colgate - Chapel House Renovation Heating Energy - Summary rev. 9/23/16 With Actual Blower Door Assembly R-Values Other Loads DORMITORY Stone Wall Window Spandrel Sill/Band Slab Edge (below grade) Roof

More information

A Method for Controlling Seismic Damage of RC Bridge Piers Subjected to Strong Aftershocks

A Method for Controlling Seismic Damage of RC Bridge Piers Subjected to Strong Aftershocks A Method for Controlling Seismic Damage of RC Bridge Piers Subjected to Strong Aftershocks Yonggang Shen 1, Chengquan Wang 1, Xu Xie 1, Yan Wang 2* 1 College of Civil Engineering and Architecture, Zhejiang

More information

Financing Energy Efficiency in Malta and Italy

Financing Energy Efficiency in Malta and Italy Financing Energy Efficiency in Malta and Italy Westin Dragonara Resort, St Julians, Malta 22 November 2018 Overview of Energy Performance of the Maltese Housing Stock Prof. Vincent Buhagiar Department

More information

ENERGY PERFORMANCE OF DIFFERENT TYPES OF DOUBLE SKIN FACADES IN VARIOUS CLIMATES

ENERGY PERFORMANCE OF DIFFERENT TYPES OF DOUBLE SKIN FACADES IN VARIOUS CLIMATES ENERGY PERFORMANCE OF DIFFERENT TYPES OF DOUBLE SKIN FACADES IN VARIOUS CLIMATES Ajla Aksamija, PhD, LEED AP BD+C, CDT1 1Department of Architecture, University Of Massachusetts Amherst, Amherst, Massachusetts

More information

DIAGRID STRUCTURAL SYSTEM: STRATEGIES TO REDUCE LATERAL FORCES ON HIGH-RISE BUILDINGS

DIAGRID STRUCTURAL SYSTEM: STRATEGIES TO REDUCE LATERAL FORCES ON HIGH-RISE BUILDINGS DIAGRID STRUCTURAL SSTEM: STRATEGIES TO REDUCE LATERAL FORCES ON HIGH-RISE BUILDINGS Nishith B. Panchal 1, Vinubhai R. Patel 2 1 PG student, Applied Mechanics & Structural Engineering Department, Faculty

More information

INVESTIGATION ON THE LOAD TRANSFER MECHANISM FOR THE JOINT OF REINFORCED CONCRETE COLUMN AND STEEL BEAM

INVESTIGATION ON THE LOAD TRANSFER MECHANISM FOR THE JOINT OF REINFORCED CONCRETE COLUMN AND STEEL BEAM INVESTIGATION ON THE LOAD TRANSFER MECHANISM FOR THE JOINT OF REINFORCED CONCRETE COLUMN AND STEEL BEAM Seng Hn KIM 1, Sang Whan HAN 2 And Li Hng LEE SUMMARY The composite framed strctres, which consist

More information

Approved baseline and monitoring methodology AM0067

Approved baseline and monitoring methodology AM0067 Approved baseline and monitoring methodolog AM0067 Methodolog for installation of energ efficient transformers in a power distribution grid I. SOURCE, DEFINITIONS AND APPLICABILITY Source This methodolog

More information

APPLICATIONS OF STRESS FIELDS TO ASSESS THE BEHAVIOR AND STRENGTH OF COUPLING BEAMS SUBJECTED TO SEISMIC ACTIONS

APPLICATIONS OF STRESS FIELDS TO ASSESS THE BEHAVIOR AND STRENGTH OF COUPLING BEAMS SUBJECTED TO SEISMIC ACTIONS Breña, Fernández Ruiz, Muttoni 3 rd fib International Congress 21 APPLICATIONS OF STRESS FIELDS TO ASSESS THE BEHAVIOR AND STRENGTH OF COUPLING BEAMS SUBJECTED TO SEISMIC ACTIONS Sergio F. Breña, University

More information

Uy Kamal Cambodia DNA

Uy Kamal Cambodia DNA Asia and Pacific Regional Workshop: Promoting CDM and Market Mechanisms 13-15 October 2014 Bangkok, Thailand U Kamal Cambodia DNA This Standardized Baseline (SB) is made available for Cambodia through

More information

Effects of tall building envelope technologies and design strategies on the urban microclimate in hot arid regions

Effects of tall building envelope technologies and design strategies on the urban microclimate in hot arid regions Effects of tall building envelope technologies and design strategies on the urban microclimate in hot arid regions Sameh Monna¹ T2 Mitigation Strategies and Techniques ABSTRACT The effects of tall building

More information

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates Kittitach Pichatwatana, and Fan Wang Abstract This paper examines the TAS computer

More information

IMPACT OF CLIMATE CHANGE

IMPACT OF CLIMATE CHANGE October 10 11, 2016. Over 90 blind-reviewed papers. Register today. http://facadetectonics.org/save-the-date-2016-facade-tectonics-world-congress/ IMPACT OF CLIMATE CHANGE Thermal and energy performance

More information

Delamination initiated by a defect

Delamination initiated by a defect IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Delamination initiated b a defect To cite this article: A Biel and H Toftegaard 2016 IOP Conf. Ser.: Mater. Sci. Eng. 139 012015

More information

Draft revision to the approved consolidated baseline and monitoring methodology ACM0013

Draft revision to the approved consolidated baseline and monitoring methodology ACM0013 Draft revision to the approved consolidated baseline and monitoring methodolog ACM0013 Consolidated baseline and monitoring methodolog for new grid connected fossil fuel fired power plants using a less

More information

Draft approved baseline and monitoring methodology AM00XX. Utilization of ammonia-plant off gas for steam generation

Draft approved baseline and monitoring methodology AM00XX. Utilization of ammonia-plant off gas for steam generation Draft approved baseline and monitoring methodolog AM00XX Utilization of ammonia-plant off gas for steam generation I. SOURCE, DEFINITIONS AND APPLICABILITY Sources This baseline and monitoring methodolog

More information

Waste Heat Recovery using Organic Rankine Cycle turbines

Waste Heat Recovery using Organic Rankine Cycle turbines Nicolas Bernier, 5ft June 2018 Waste Heat Recover using Organic Rankine Ccle turbines Industrial waste heat : the example of France (1) Heat balance, fuel furnace, permanent regime Fumes loss 25 to 60

More information

THEORY AND APPLICATION OF THE GENERAL METHOD OF EUROCODE 3 PART 1-1

THEORY AND APPLICATION OF THE GENERAL METHOD OF EUROCODE 3 PART 1-1 EUROSTEEL 2011, August 31 - September 2, 2011, Budapest, Hungar THEORY AD APPLICATIO OF THE GEERAL METHOD OF EUROCODE 3 PART 1-1 Ferenc Papp a, József Szalai b a Budapest Universit of Technolog and Economics,

More information

Energy Codes and the Building Envelope

Energy Codes and the Building Envelope Energy Codes and the Building Envelope Goal of Energy Efficient Design A Few Acronyms ASHREA = American Society of Heating, Refrigerating, and Air-Conditioning Engineers ICC = International Code Council

More information

EXPERIMENTAL AND ANALYTICAL INVESTIGATIONS OF STEEL AND COMPOSITE TRUSSES

EXPERIMENTAL AND ANALYTICAL INVESTIGATIONS OF STEEL AND COMPOSITE TRUSSES Advanced Steel Construction Vol. 7, No. 1, pp. 17-26 (2011) 17 EXPERIMENTAL AND ANALYTICAL INVESTIGATIONS OF STEEL AND COMPOSITE TRUSSES S.L. Chan 1,* and M. Fong 2 1 Professor, Department of Civil and

More information

A Study on the Evaluation of Heating and Cooling Energy Efficiency in Residential Buildings for Climatic Zones of Turkey

A Study on the Evaluation of Heating and Cooling Energy Efficiency in Residential Buildings for Climatic Zones of Turkey Journal of Energy and Power Engineering 8 (2014) 20452052 D DAVID PUBLISHING A Study on the Evaluation of Heating and Cooling Energy Efficiency in Residential Buildings for Climatic Zones of Turkey Suzi

More information

Chapter 9 Integration of BSA tools in building design tools 909

Chapter 9 Integration of BSA tools in building design tools 909 Chapter 9 Integration of BSA tools in building design tools 99 Integrated Approach for Intelligent Envelope Design: Simulation performance of building envelope design strategies and technologies during

More information

Approved consolidated baseline methodology ACM0001. Consolidated baseline and monitoring methodology for landfill gas project activities

Approved consolidated baseline methodology ACM0001. Consolidated baseline and monitoring methodology for landfill gas project activities Approved consolidated baseline methodolog ACM0001 Consolidated baseline and monitoring methodolog for landfill gas project activities I. SOURCE AND APPLICABILITY Sources This methodolog is based on elements

More information

PROGRAMME OF ACTIVITIES DESIGN DOCUMENT (PoA-DD)

PROGRAMME OF ACTIVITIES DESIGN DOCUMENT (PoA-DD) CDM Executive Board Page 1 PROGRAMME DESIGN DOCUMENT FORM FOR SMALL-SCALE CDM PROGRAMMES OF ACTIVITIES (F-CDM-SSC-PoA-DD) Version 02.0 PROGRAMME OF ACTIVITIES DESIGN DOCUMENT (PoA-DD) SECTION A. General

More information

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies COM Elithis Tower in Dijon, France Elithis Tower, located in Dijon, France, provides strong evidence that net zero energy office buildings are achievable in near future. The building, which was designed

More information

INTERNATIONAL CODE COUNCIL 2009/2010 CODE DEVELOPMENT CYCLE

INTERNATIONAL CODE COUNCIL 2009/2010 CODE DEVELOPMENT CYCLE INTENATIONAL CODE COUNCIL 09/10 CODE DEVELOPMENT CYCLE 09/10 FINAL ACTION AGENDA UPDATE #2 INTENATIONAL ENEGY CONSEVATION CODE Updated 10-22-10 October 25. 27-31, 10 CHALOTTE CONVENTION CENTE CHALOTTE,

More information

A L C H E M # $ % &

A L C H E M # $ % & ALCHEMY! @ # $ % & BUILDING BLOCKS How much space are you looking for? 1x 300-850 SF 2x 1200-1600 SF 3x 1200-2000 SF 4x 1800-2400 SF H 8 or 9 interior 14 or 16 W L up to 60 The maximum dimensions for

More information

Damping Patch Placement on Outdoor Unit of Air- Conditioner by Using Structural Intensity Technique

Damping Patch Placement on Outdoor Unit of Air- Conditioner by Using Structural Intensity Technique Purdue Universit Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 004 Damping Patch Placement on Outdoor Unit of Air- Conditioner b Using Structural

More information

CLEAN DEVELOPMENT MECHANISM PROJECT DESIGN DOCUMENT FORM (CDM-SSC-PDD) Version 03 - in effect as of: 22 December 2006 CONTENTS

CLEAN DEVELOPMENT MECHANISM PROJECT DESIGN DOCUMENT FORM (CDM-SSC-PDD) Version 03 - in effect as of: 22 December 2006 CONTENTS CLEAN DEVELOPMENT MECHANISM PROJECT DESIGN DOCUMENT FORM (CDM-SSC-PDD) Version 03 - in effect as of: 22 December 2006 CONTENTS A. General description of the small scale project activit B. Application of

More information

Uy Kamal Deputy Director, Ministry of Environment Cambodia

Uy Kamal Deputy Director, Ministry of Environment Cambodia Fourth workshop on enhancing the regional distribution of CDM projects in Asia and the Pacific Opportunities for CDM and carbon markets post 2012-4 5 September 2013 ADB Headquarters, Manila, the Philippines

More information

ECMC Skilled Nursing Facility Architectural Engineering Senior Thesis AE 481W Thesis Proposal Dr. Ali Memari January 13 th, 2012

ECMC Skilled Nursing Facility Architectural Engineering Senior Thesis AE 481W Thesis Proposal Dr. Ali Memari January 13 th, 2012 ECMC Skilled Nursing Facility Architectural Engineering Senior Thesis 2011 Class: Subject: Faculty Consultant: Submitted: AE 481W Thesis Proposal Dr. Ali Memari January 13 th, 2012 Table of Contents Executive

More information

10 tips from your Architect

10 tips from your Architect 10 tips from your Architect Within the context of the national week of Energy Efficiency, in collaboration with the Energy Efficiency Management Office, the Mauritius Association of Architects offers you

More information

THE PARAMETERS EFFECT ON SUSTAINABLE BUILT ENVIRONMENT DESIGN

THE PARAMETERS EFFECT ON SUSTAINABLE BUILT ENVIRONMENT DESIGN THE PARAMETERS EFFECT ON SUSTAINABLE BUILT ENVIRONMENT DESIGN M. Tolga Akbulut 1, Dilek Ekþi Akbulut 1, Gül Koçlar Oral 2 1 Faculty of Architecture, Yýldýz Technical University, Turkey, 2 Faculty of Architecture,

More information

Draft baseline and monitoring methodology AM00XX

Draft baseline and monitoring methodology AM00XX Thirt-eighth meeting Draft baseline and monitoring methodolog AM00XX Baseline and monitoring methodolog for new grid connected power plants using waste gas fired Combined Ccle Gas Turbine technolog instead

More information

Exercise 4: Assessing Urban Heat Island Impacts and Evaluating Water Waste and Energy Performance

Exercise 4: Assessing Urban Heat Island Impacts and Evaluating Water Waste and Energy Performance ARCH 5550 Zero+DESIGN Envisioning the Sustainable Campus Integrating carbon, energy, and water management strategies toward zero- and net-positive design "Every eight months, nearly 11 million gallons

More information

THE IMPACT OF BUILDING ORIENTATION ON ENERGY USE: A CASE STUDY IN BUNG HATTA UNIVERSITY, INDONESIA

THE IMPACT OF BUILDING ORIENTATION ON ENERGY USE: A CASE STUDY IN BUNG HATTA UNIVERSITY, INDONESIA International Journal of Real Estate Studies, Volume 11 Number 1 2017 THE IMPACT OF BUILDING ORIENTATION ON ENERGY USE: A CASE STUDY IN BUNG HATTA UNIVERSITY, INDONESIA Rini Mulyani 1*, Inna Kholidasari

More information

Council on Tall Buildings. and Urban Habitat BACKGROUND SECTION STEEL REINFORCED CONCRETE SHEAR WALL STEEL PLATE COMPOSITE SHEAR WALL

Council on Tall Buildings. and Urban Habitat BACKGROUND SECTION STEEL REINFORCED CONCRETE SHEAR WALL STEEL PLATE COMPOSITE SHEAR WALL BACKGROUND CATALOG SECTION STEEL REINFORCED CONCRETE SHEAR WALL STEEL PLATE COMPOSITE SHEAR WALL STEEL PLATE SHEAR WALL CONCLUSION BACKGROUND With the rapid development of our economy and advancement of

More information

The Effect of Geometric Shape and Building Orientation on Minimising Solar Insolation on High-Rise Buildings in Hot Humid Climate

The Effect of Geometric Shape and Building Orientation on Minimising Solar Insolation on High-Rise Buildings in Hot Humid Climate Journal of Construction in Developing Countries, Vol. 12, No. 1, 2007 The Effect of Geometric Shape and Building Orientation on Minimising Solar Insolation on High-Rise Buildings in Hot Humid Climate *Chia

More information

Part 1 Review Questions on material covered in Midterms I & II

Part 1 Review Questions on material covered in Midterms I & II 1 Arch 463 ECS Fall 2001 Name FINAL 40 Multiple Choice Questions Part 1 Review Questions on material covered in Midterms I & II 1. Passive systems for environmental control A. can enhance human comfort

More information

productive architecture Kiss + Cathcart, Architects 44 COURT ST. TOWER C, BROOKLYN, NY t f

productive architecture Kiss + Cathcart, Architects 44 COURT ST. TOWER C, BROOKLYN, NY t f productive architecture Kiss + Cathcart, Architects 44 COURT ST. TOWER C, BROOKLYN, NY 11201 t +1 718 237 2786 f +1 718 237 2025 www.kisscathcart.com the 2020 tower The 2020 Tower is a mixed-use, 150 story,

More information

Parapet Wall Design Brian Erickson, P.E., RRC Ryan Krug - 8:30 am 10:00 am

Parapet Wall Design Brian Erickson, P.E., RRC Ryan Krug - 8:30 am 10:00 am Parapet Wall Design Brian Erickson, P.E., RRC Ryan Krug - 8:30 am 10:00 am NOVEMBER 14, 2017 Speakers Brian D. Erickson, P.E., RRC Vice President Midwest, Pie Consulting & Engineering Licensed PE in 6

More information

EFFECT OF GEAR POSITIONS ON AIRFIELD RIGID PAVEMENT CRITICAL STRESS LOCATIONS

EFFECT OF GEAR POSITIONS ON AIRFIELD RIGID PAVEMENT CRITICAL STRESS LOCATIONS EFFECT OF GEAR POSITIONS ON AIRFIELD RIGID PAVEMENT CRITICAL STRESS LOCATIONS B: Jeffer Roesler, Francisco Evangelista Jr, and Marcelo Domingues Department of Civil and Environmental Engineering Universit

More information

MULTIDISCIPLINARY DESIGN PROCESS: URBAN, ARCHITECTURAL AND TECHNOLOGICAL ANALYSES FOR ENERGY-EFFICIENT RESIDENTIAL BUILDINGS IN NORTHERN ITALY

MULTIDISCIPLINARY DESIGN PROCESS: URBAN, ARCHITECTURAL AND TECHNOLOGICAL ANALYSES FOR ENERGY-EFFICIENT RESIDENTIAL BUILDINGS IN NORTHERN ITALY Int. Journal for Housing Science, Vol.35, No.1 pp. 11-21, 2011 Published in the United States MULTIDISCIPLINARY DESIGN PROCESS: URBAN, ARCHITECTURAL AND TECHNOLOGICAL ANALYSES FOR ENERGY-EFFICIENT RESIDENTIAL

More information

Approved baseline and monitoring methodology AM0063

Approved baseline and monitoring methodology AM0063 Approved baseline and monitoring methodolog AM0063 Recover of CO 2 from tail gas in industrial facilities to substitute the use of fossil fuels for production of CO 2 I. SOURCE, DEFINITIONS AND APPLICABILITY

More information

ELASTIC-PLASTIC BEHAVIOR OF REINFORCED CONCRETE COLUMN-STEEL BEAM JOINTS UNDER BI-DIRECTIONAL LOADING

ELASTIC-PLASTIC BEHAVIOR OF REINFORCED CONCRETE COLUMN-STEEL BEAM JOINTS UNDER BI-DIRECTIONAL LOADING 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 24 Paper No. 135 ELASTIC-PLASTIC BEHAVIOR OF REINFORCED CONCRETE COLUMN-STEEL BEAM JOINTS UNDER BI-DIRECTIONAL LOADING

More information

Draft approved baseline and monitoring methodology AM00XX

Draft approved baseline and monitoring methodology AM00XX Draft approved baseline and monitoring methodolog AM00XX Recover of CO 2 from tail gas in industrial facilities to substitute the use of fossil fuels for production of CO 2 I. SOURCE, DEFINITIONS AND APPLICABILITY

More information

Parametric Louver Design System Based On Direct Solar Radiation Control Performance

Parametric Louver Design System Based On Direct Solar Radiation Control Performance Parametric Louver Design System Based On Direct Solar Radiation Control Performance Jaepil Choi 1, Taekyoung Lee* 2, Euisoon Ahn 2 and Gensong Piao 2 1 Professor, Department of Architecture, Seoul National

More information

I. SOURCE AND APPLICABILITY

I. SOURCE AND APPLICABILITY NOTE: The revision of this methodolog is applicable to project activities where biomass would deca under anaerobic conditions in the baseline scenario, the DOEs shall make publicl available for 30 das

More information

299: Ilan Ramon-Elementary School, Jerusalem

299: Ilan Ramon-Elementary School, Jerusalem 299: Ilan Ramon-Elemar School, Jerusalem Ruth LAHAV Arch. 1* Amos Halfon Eng. 2* * R. Lahav Rigg Architects and Town Planners LTD 1* Tel Aviv, Israel 1* lr_misrd@netvision.net.il Advance Sstems LTD (AES)Institution,

More information

CCHVAC REHVA Workshop in CLIMA nzeb experiences in South Europe and Mediterranean Climate

CCHVAC REHVA Workshop in CLIMA nzeb experiences in South Europe and Mediterranean Climate CCHVAC REHVA Workshop in CLIMA 2019 nzeb experiences in South Europe and Mediterranean Climate Stefano P. Corgnati Aalborg - 2016 Mediterranean climate North Europe South Europe - Control of thermal loads

More information

Comparative Study of Energy Consumption Optimization for. Different Orientations of School`s Buildings in Jordan

Comparative Study of Energy Consumption Optimization for. Different Orientations of School`s Buildings in Jordan Comparative Study of Energy Consumption Optimization for Different Orientations of School`s Buildings in Jordan Main Author: Arch. Tala Samir Awadallah Co.Author: Dr. Omaimah Ali Al-Arja School of Architecture

More information

EXTERNAL SHADING DEVICES

EXTERNAL SHADING DEVICES EXTERNAL SHADING DEVICES External shading devices, such as eaves, awnings, and verandahs, play a critical role in reducing unwanted solar heat gain, especially in cooling-dominant climates and during summer

More information

Evolving Traditional Practices for Sustainable Construction in the Present Paper presented at INTBAU International Conference 11 th 14 th Jan.

Evolving Traditional Practices for Sustainable Construction in the Present Paper presented at INTBAU International Conference 11 th 14 th Jan. Evolving Traditional Practices for Sustainable Construction in the Present Paper presented at INTBAU International Conference 11 th 14 th Jan. 2007 Abstract In India we have entered a phase of urban growth

More information

ECMC Skilled Nursing Facility Architectural Engineering Senior Thesis AE 481W Thesis Proposal Dr. Ali Memari December 12 th, 2011

ECMC Skilled Nursing Facility Architectural Engineering Senior Thesis AE 481W Thesis Proposal Dr. Ali Memari December 12 th, 2011 ECMC Skilled Nursing Facility Architectural Engineering Senior Thesis 2011 Class: Subject: Faculty Consultant: Submitted: AE 481W Thesis Proposal Dr. Ali Memari December 12 th, 2011 Table of Contents Executive

More information

AWERProcedia Information Technology & Computer Science

AWERProcedia Information Technology & Computer Science AWERProcedia Information Technolog & Computer Science Vol 3 (213) 1935-194 3 rd World Conference on Information Technolog (WCIT-212) Finite Element Simulation of Thin Interphase Laer between Two Glass

More information

COUPLING STRATEGY OF HVAC SYSTEM SIMULATION AND CFD PART 2: STUDY ON MIXING ENERGY LOSS IN AN AIR-CONDITIONED ROOM

COUPLING STRATEGY OF HVAC SYSTEM SIMULATION AND CFD PART 2: STUDY ON MIXING ENERGY LOSS IN AN AIR-CONDITIONED ROOM 12th Conference of International Building Performance Simulation Association, Sdne, 14-16 November. COUPLING STRATEGY OF HVAC SYSTEM SIMULATION AND CFD PART 2: STUDY ON MIXING ENERGY LOSS IN AN AIR-CONDITIONED

More information

In the course of the last three

In the course of the last three Laser Doppler Velocimetr (LDV) An Accredited Method for of Large Flow Meters In the course of the last three ears, the Danish Technological Institute has achieved as the onl laborator in the world accreditation

More information

Study on Bending Strength of Web-Bolted Moment Joints of Aluminum Alloy Beam Exposed to Fire

Study on Bending Strength of Web-Bolted Moment Joints of Aluminum Alloy Beam Exposed to Fire Stud on Bending Strength of Web-Bolted oment Joints of Aluminum Allo Beam Eposed to Fire HISASHI ISHII 1, TAKEO HIRASHIA 2, and HIDEKI UESUGI 3 1 Global Business Department JS Group Corporation 3-3-2,

More information

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED Ministry of Municipal Affairs PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED CHANGE NUMBER: SOURCE: B-05-10-03 Ontario-mNBC CODE REFERENCE: Division B / 5.10.3. DESCRIPTION OF THE

More information

A ALYSIS OF STAIRWELLS PERFORMA CE A D DAMAGE DURI G WE CHUA EARTHQUAKE

A ALYSIS OF STAIRWELLS PERFORMA CE A D DAMAGE DURI G WE CHUA EARTHQUAKE A ALYSIS OF STAIRWELLS PERFORMA CE A D DAMAGE DURI G WE CHUA EARTHQUAKE Bixiong Li *, Zhe Wang 2, Khalid M. Mosalam 3, Xuan Wang 4, Zhou Wei 5 Associate Professor, Dept. of Civil Engineering, Sichuan Universit,

More information

Design of Adjustable Width Train Bogie and Structure Finite Element Analysis Jun DAI

Design of Adjustable Width Train Bogie and Structure Finite Element Analysis Jun DAI 017 International Conference on Energ, Power and Environmental Engineering (ICEPEE 017) ISBN: 978-1-60595-456-1 Design of Adjustable Width Train Bogie and Structure Finite Element Analsis Jun DAI Mechanical

More information

Comprehensive Examinations- Spring DESIGN Question

Comprehensive Examinations- Spring DESIGN Question Universit of California, Berkele Department of Civil and Environmental Engineering Structural Engineering, Mechanics and Materials Comprehensive Eaminations- Spring 2014 DESIGN Question Consider ONLY one

More information

SOLAR PASSIVE DESIGN: PRINCIPLES AND PRACTICE

SOLAR PASSIVE DESIGN: PRINCIPLES AND PRACTICE SOLAR PASSIVE DESIGN: PRINCIPLES AND PRACTICE Understanding Climate and Atmosphere Human impact on global weather Energy outlook in India Energy needs in buildings Comfort zone Solar passive design- Case

More information

Development of Al/Cu Dissimilar Joint by New Friction Welding Method

Development of Al/Cu Dissimilar Joint by New Friction Welding Method The The 3rd 3rd International Conference on on Design Engineering and Science, ICDES 214 Pilsen, Czech Pilsen, Republic, Czech August Republic, 31 September 1-3, 214 Development of Al/Cu Dissimilar Joint

More information

Benefits in Speed and Logistics using the RL System. snapnrack.com

Benefits in Speed and Logistics using the RL System. snapnrack.com Benefits in Speed and Logistics using the RL System snapnrack.com Agenda About SnapNrack Overview of Residential Solar Mounting Systems Benefits of railless systems What you should look for in a railless

More information

TRANSSOLAR. 6 th Canadian German Conference on Energy Efficiency Retrofits in Buildings. September 22, 2015 Toronto

TRANSSOLAR. 6 th Canadian German Conference on Energy Efficiency Retrofits in Buildings. September 22, 2015 Toronto 6 th Canadian German Conference on Energy Efficiency Retrofits in Buildings September 22, 2015 Toronto JOSHUA MONK VANWYCK vanwyck@transsolar.com WHO IS? Stuttgart Founded: 1992 Employees: 50 Main Activities:

More information

GENERALIZED CRITERIA OF ENERGY PERFORMANCE EVALUATION IN EARLY DESIGN STAGES OF NEARLY ZERO-ENERGY BUILDINGS

GENERALIZED CRITERIA OF ENERGY PERFORMANCE EVALUATION IN EARLY DESIGN STAGES OF NEARLY ZERO-ENERGY BUILDINGS GENERALIZED CRITERIA OF ENERGY PERFORMANCE EVALUATION IN EARLY DESIGN STAGES OF NEARLY ZERO-ENERGY BUILDINGS Ivanova St. Chief-Asst. Prof. Dr. Arch. Department of Computer-Aided Engineering University

More information

Two Intensities Analysis of London Accord

Two Intensities Analysis of London Accord Two Intensities Analsis of London Accord Hiroshige TANAKA Professor of Facult of Economics, Chuo Universit, Higashinakano 742-1,Hachioi-cit, Toko 192-0393, JAPAN. abstract London Accord is constructed

More information

Architectural Systems for Building Facades. Leader and Expert in High Performance Curtain walls systems

Architectural Systems for Building Facades. Leader and Expert in High Performance Curtain walls systems Architectural s for Building Facades Leader and Expert in High Performance Curtain walls systems STEKAR CURTAIN WALLS SYSTEMS Definition: A SYSTEM IS A SET OF ELEMENTS THAT INTERACT WITH ONE ANOTHER ACCORDING

More information

Compactness ratio : 1.2. Openings ratio : 26% (thermic envelope / inhabitable area) Smaller is better 1.9 = bad < 0.8 = good

Compactness ratio : 1.2. Openings ratio : 26% (thermic envelope / inhabitable area) Smaller is better 1.9 = bad < 0.8 = good ENERGIZED CANOPY Compactness ratio : 1.2 (thermic envelope / inhabitable area) Smaller is better 1.9 = bad < 0.8 = good A good compactness ratio lets to need less material and energy to build the buildings

More information

AEES 2009 Annual Conference Seismic Assessment of Glazed Façade Systems

AEES 2009 Annual Conference Seismic Assessment of Glazed Façade Systems AEES 2009 Annual Conference Seismic Assessment of Glazed Façade Systems Sivanerupan S 1, Wilson JL 2, Gad EF 3, Lam NTK 4 1.Corresponding Author. PhD student, Faculty of Engineering, and Industrial Sciences,

More information

Boilers will be used for space heating, domestic hot water and technical purposes.

Boilers will be used for space heating, domestic hot water and technical purposes. GENERAL INFORMATION Title of NAMA Introduction 1000 MW of small biomass boilers in Serbia of the Mitigation Action The NAMA aims to install new biomass boilers totaling 1,000 MW that can provide around

More information

ULMA S COMPROMISE & CONTRIBUTION TO LEED CERTIFICATION

ULMA S COMPROMISE & CONTRIBUTION TO LEED CERTIFICATION ULMA S COMPROMISE & CONTRIBUTION TO LEED CERTIFICATION UNDERSTANDING LEED Leadership in Energy and Environmental Design- LEED is an internationally recognized green building certification system, providing

More information

Thermal and Energy Performance of Double Skin Facades in Different Climate Types

Thermal and Energy Performance of Double Skin Facades in Different Climate Types University of Massachusetts Amherst From the SelectedWorks of Ajla Aksamija 2017 Thermal and Energy Performance of Double Skin Facades in Different Climate Types Dr. Ajla Aksamija, University of Mass Available

More information

3-Dimensional Thermal Analysis of Lenmak EnvaTherm and SpandrelTherm Backpan Assemblies

3-Dimensional Thermal Analysis of Lenmak EnvaTherm and SpandrelTherm Backpan Assemblies Report Number: 5160440 August 18 th, 2016 3-Dimensional Thermal Analysis of Lenmak EnvaTherm and SpandrelTherm Backpan Assemblies Presented to: Lenmak Exterior Innovations Inc. 10404-176 Street Edmonton,

More information

Intelligent tall building envelope technologies and design alternatives for comfort and energy efficiency in hot, arid climate

Intelligent tall building envelope technologies and design alternatives for comfort and energy efficiency in hot, arid climate Intelligent tall building envelope technologies and design alternatives for comfort and energy efficiency in hot, arid climate Sameh Monna, Building Environment Science & Technology Department, Polytechnic

More information

INTERACTION DIAGRAMS AXIAL FORCE-BENDING MOMENT FOR FIRE EXPOSED STEEL-CONCRETE COMPOSITE SECTIONS

INTERACTION DIAGRAMS AXIAL FORCE-BENDING MOMENT FOR FIRE EXPOSED STEEL-CONCRETE COMPOSITE SECTIONS Proceedings of the International Conference in Dubrovnik, 15-16 October 15 INTERACTION DIAGRAMS AXIAL FORCE-BENDING MOMENT FOR FIRE EXPOSED STEEL-CONCRETE COMPOSITE SECTIONS Milivoje Milanovic a, Meri

More information

Indicative simplified baseline and monitoring methodologies for selected small-scale CDM project activity categories

Indicative simplified baseline and monitoring methodologies for selected small-scale CDM project activity categories CDM Executive Board./Version 14 for selected small-scale CDM proect activit categories Electricit generation b the user (cont) TYPE I - RENEWABLE ENERGY PROJECTS Proect participants shall appl the general

More information

CEN/TC 89 - Thermal performance of buildings and building components

CEN/TC 89 - Thermal performance of buildings and building components CEN/TC 89 - Thermal performance of buildings and building components Standard reference EN 1934:1998 EN 1946-1:1999 EN 1946-2:1999 EN 1946-3:1999 EN 1946-4:2000 EN 1946-5:2000 6946:2007 7345:1995 8497:1996

More information

A STUDY ON DESIGN OPTIMIZATION OF A NEAR NET-ZERO ENERGY HOUSE

A STUDY ON DESIGN OPTIMIZATION OF A NEAR NET-ZERO ENERGY HOUSE Int. Journal for Housing Science, Vol.37, No.1 pp.23-31, 2013 Published in the United States A STUDY ON DESIGN OPTIMIZATION OF A NEAR NET-ZERO ENERGY HOUSE Narghes Doust, Gabriele Masera and Marco Imperadori

More information

Curtainwalls. Brussels Window. Objectives. Windows & Curtainwalls. Curtainwalls. 1 R2 R3. High tech? Low tech?

Curtainwalls. Brussels Window. Objectives. Windows & Curtainwalls. Curtainwalls.  1 R2 R3. High tech? Low tech? Curtainwalls Windows have long been important to buildings Brussels Window Objectives Windows & Curtainwalls This talk aims to Develop awareness of curtainwall performance appreciate impact of performance

More information

Applications of ECOTECT and HEED in building energy analysis - Case study: A typical tube house in Hanoi

Applications of ECOTECT and HEED in building energy analysis - Case study: A typical tube house in Hanoi Applications of ECOTECT and HEED in building energy analysis - Case study: A typical tube house in Hanoi (1) Wei-Hwa Chiang (2) Nguyen Ngoc Tu (3) Jian Sheng Huang (1)whch@mail.ntust.edu.tw (2)M9602806@mail.ntust.edu.tw

More information

THE STRANGE AND SAD STORY OF QATAR S FIRST PASSIVHAUS

THE STRANGE AND SAD STORY OF QATAR S FIRST PASSIVHAUS THE STRANGE AND SAD STORY OF QATAR S FIRST PASSIVHAUS Dr. Alex Amato, Head of Sustainability Dr. Cynthia Skelhorn, Research Specialist Qatar Green Building Council AFFORDABLE HOUSING & SUSTAINABLE COMMUNITIES

More information

/ TABLE OF CONTENTS /

/ TABLE OF CONTENTS / / TABLE OF CONTENTS / INTRODUCTION ///////////////////////////////////////////////////////////////////////////////////////////////////////////// 1 ROOFS WITH INSULATION ENTIRELY ABOVE DECK I-CODE AND ASHRAE

More information

Flexibility in typology, technology, construction and performances: an innovative approach for an open construction kit

Flexibility in typology, technology, construction and performances: an innovative approach for an open construction kit Proceedings of the XVIII IAHS World Congress April 16 19, 2012, Istanbul, Turkey Flexibility in typology, technology, construction and performances: an innovative approach for an open construction kit

More information

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009 Is Your Envelope Effective? Patrick Roppel P Eng Patrick Roppel P.Eng BCBEC Luncheon January 29, 2009 Goals for this Presentation Why we might be concerned with heat loss through the envelope (U-value

More information

Approved consolidated baseline methodology ACM0001. Consolidated baseline and monitoring methodology for landfill gas project activities

Approved consolidated baseline methodology ACM0001. Consolidated baseline and monitoring methodology for landfill gas project activities Approved consolidated baseline methodolog ACM0001 Consolidated baseline and monitoring methodolog for landfill gas project activities I. SOURCE AND APPLICABILITY Sources This methodolog is based on elements

More information

TECHNICAL NOTE No.4 Simulated Windborne Debris Impact Testing of Building Envelope Components (Version 4 Published 10 January 2017)

TECHNICAL NOTE No.4 Simulated Windborne Debris Impact Testing of Building Envelope Components (Version 4 Published 10 January 2017) Cyclone Testing Station College of Science and Engineering James Cook University Townsville QLD 4811 Australia Telephone +61 7 4781 4722 Facsimile +61 7 4781 6788 Email: cts.testing@jcu.edu.au www.jcu.edu.au/cts

More information

Sustainable Development

Sustainable Development Sustainable Development Julian Sutherland Director of Sustainable Development April 2010 What is sustainable development? The Brundtland Commission defined sustainable development as: development that

More information

Composite floor systems in highrise towers A very cost-effective construction using membrane action in fire design

Composite floor systems in highrise towers A very cost-effective construction using membrane action in fire design Composite floor systems in highrise towers A very cost-effective construction using membrane action in fire design Dipl.-Ing. (FH) Martin Stadler * Prof. Dr.-Ing. Dipl. Wirt.-Ing. (NDS) Martin Mensinger

More information

Annex 12 GUIDELINES ON APPORTIONING EMISSIONS FROM PRODUCTION PROCESSES BETWEEN MAIN PRODUCT AND CO- AND BY-PRODUCTS. (Version 01)

Annex 12 GUIDELINES ON APPORTIONING EMISSIONS FROM PRODUCTION PROCESSES BETWEEN MAIN PRODUCT AND CO- AND BY-PRODUCTS. (Version 01) Page 1 GUIDELINES ON APPORTIONING EMISSIONS FROM PRODUCTION PROCESSES BETWEEN MAIN PRODUCT AND CO- AND BY-PRODUCTS I. Scope and rationale of the guidelines (Version 01) 1. The purpose of these guidelines