1 Gar-Rock Gar-Rock is an all-weather, fast setting, chemical action concrete patching material designed to patch concrete surfaces where quick, permanent repairs are desired. Gar-Rock can be used at below freezing temperatures. It exhibits high compressive and flexural strength, and it forms a permanent bond to ordinary concrete. Gar-Rock is mixed with water only. It can be used in damp areas, and the material does not emit any toxic fumes. PRODUCT ADVANTAGES Reduces Downtime - Sets in 15 minutes. Ready for truck traffic in 45 minutes. Strength - Repaired area is stronger than the original surface. Versatile - Permanent repairs can be made anywhere, in any kind of weather. Easily Applied - Mixes with ordinary tap water. Pours or trowels easily into place. No primers required. Gar-Rock should only be applied to properly prepared surfaces. A sound base is essential for effective repairs. Chip out the area to be repaired approximately 1/4" (6.35 mm) deep. Remove all oil, grease, dust, dirt, and loose concrete material. Dampen the sides and the bottom of the hole. Remove any standing water from the area to be repaired. Use a clean mortar box and hoe or paddle type mortar mixer to mix the Gar-Rock. Only 3 1/2 pints (1.66 liters) of clean water are required to completely mix each 45 pound (20.4 kg) pail. Excess water reduces the strength of the cured product. Gar-Rock should be applied immediately after it is mixed. Place or force the mix into the prepared area and trowel until a smooth level surface has been reached. Work the material well into the base to insure a good bond. Do not overwork or overtrowel, and do not attempt to re-temper the mixture with additional water. For deep repairs, up to 25 lbs. (11.3 kg) of 3/8" (9.53 mm) aggregate can be added to increase yield. The aggregate mix should be applied up to 1/4" (6.35 mm) of the surface. Gar-Rock is then used to smooth and level the repair. USES Gar-Rock Gar-Rock is suitable for virtually all industrial concrete floor repairs. Gar-Rock can also be used to repair sidewalks, curbs, freezer rooms, truck docks and chuckholes. It is ideally suited for in-plant road maintenance and as a floor leveler for both interior and exterior applications. Gar-Rock makes an excellent filler for pitch pockets. Fill the pitch pocket with Gar-Rock 1" (25.4 mm) from the top and the rest is filled with Seal-Tite. Each unit of Gar-Rock will fill 648 cubic inches (0.01 m 3 ). Multiply the size of the pitch pan by the depth to get the cubic inches of the pitch pan, then divide into 648 and that will give you the number of pitch pans you can fill with one unit of Gar-Rock. Flexural Strength 3 x 4 x 16 Prisms Compressive Strength *Set Time & Strength 72 F (22 C) Shelf Life 550 psi 1 hour = 2,000 psi 28 days = 8,500 psi 1 hour = 2,000 psi 24 hours = 6,000 psi 3 days = 7,000 psi 1 Year - properly stored Coverage 36 sq. ft. (3.34m 2 1/8" (3.18 mm) thickness Packaging 45 lbs. (20.4 kg) pail 5 gallon (18.9 l) * Time and strength varies depending on air temperature and humidity. Garland Canada, Inc. The Garland Company UK, LTD. Unit 5 Glevum Works, Upton Street Gloucester, United Kingdom GL1 4LA Tests verified by independent laboratories. Actual roof performance specifications will vary depending on test speed and temperature. Data reflects samples randomly collected. A ± 10% variation may be experienced. The above data supersedes all previously published information. Consult your local Garland Representative or Garland Corporate Office for more information. Gar-Rock is a registered trademark of The Garland Company, Inc Garland Industries, Inc. G-R 0213

2 Seal-Tite Seal-Tite is a two-part, pourable, self-leveling, 100% solids, urethane sealant. It is designed to provide a high performance, elastic, weather resistant, durable seal to pitch pans against water entry. Seal-Tite is asbestos-free. Many problems associated with a building's roof area start with leaks around roof penetrations. Pitch pans are a common source for water entry. As they age and receive constant exposure to damaging weather conditions, materials commonly used in pitch pans shrink due to oil or solvent release. This soon causes areas for water entry that can damage the roofing system and eventually saturate the insulation below. Wet and deteriorating insulation soon loses its insulating value and allows moisture to negatively affect the underlying deck. Seal-Tite is designed to flow and fill every irregularity in the pitch pan. Since it is 100% solids, it will not shrink as it ages. With outstanding elongation and recovery properties, this product provides a long-term, flexible seal that readily resists UV, ozone, and moisture. PERFORMANCE ADVANTAGES 100% Solids - Seal-Tite is a modified urethane sealant that contains no volatiles. It will provide a durable watertight seal that will not shrink as it ages. Seal-Tite outlasts all commonlyused tar or asphalt mastics. Self-leveling - Seal-Tite fills and readily conforms to all irregularly shaped and various sized pitch pans. Mixing - Seal-Tite's two components are colored differently to ensure proper mixing. Mix Part A with Part B until uniform color is achieved. SURFACE PREPARATION Clean the surface of both the newly installed pitch pan and any projections contained within the pitch pan, of all oils, tars, asphalts and other contaminants. After cleaning, scrub the top inside inch of the pan with steel wool. Next, fill the pitch pan with Gar-Rock within two inches of the top of the pan. Allow the Gar-Rock to fully cure (see Gar-Rock instructions). After the Gar-Rock has completely cured, pour the Seal-Tite into the pan until it is level with the top. Apply a hood (when appropriate) over the finished pitch pan and caulk the top of the hood. Gar-Rock Penetration Seal-Tite (2 Deep) For best results, apply Seal-Tite at temperatures between 40 F (4 C) and 90 F (32 C). Seal-Tite is designed to be tack-free within 8 hours. PRECAUTIONS Avoid prolonged breathing of vapors and contact with skin or eyes. Wash hands thoroughly after use. Upon accidental contact with eyes, flush thoroughly with water and seek medical attention. When applying Seal-Tite to an existing pitch pan, remove all existing waterproofing and clean all metal with a wire brush. Seal-Tite may have an adverse affect if it comes in contact with residual asphalt or tar. Seal-Tite should not be used to "top off" existing pitch pans. Do not apply Seal-Tite over wet or oily surfaces or if rain is expected with in 8 hours. Seal-Tite is incompatible with TPO, Hypalon and APP membranes. STORAGE LIFE Approved Pitch Pan (Min. 4 High) Storage life of Seal-Tite is twelve months from date of manufacture when stored below 80 F (27 C) in original unopened containers.

3 Seal-Tite Seal-Tite Eco-Facts Seal-Tite Viscosity A Component - 100,000 to 150,000 cps B Component to 2,000 cps VOC 0 g/l Pot Life End Point 1 million F (37.8 C) - 20 to F (21.1 C) - 40 to 50 minutes Durometer (ASTM D 2240) 40 to 50 shore Elongation F (21.1 C) 250% Specific Gravity Cured Rubber 1.01 Tensile Strength Peel Adhesion (ASTM C 836) Moisture Vapor Transmission (ASTM E 96) Coverage Packaging (Kit) 200 psi at 100 mil Cotton Webbing Bonded to: Aluminum - 15 pli Concrete - 18 pli Steel Galvanized - 19 pli Wood - 20 pli 0.05 Perm. Inches 1gallon (3.8 l) will fill three pitch pans 6 in. x 6 in. x 2 in. depth (15.24 cm x cm x 5.08 cm) Two - 1 gallon (3.8 l) units For specific application recommendations and coverage rates, please contact your local Garland Representative or Garland Technical Service Department. Garland Canada Inc. The Garland Company UK, LTD Unit 5 Glevum Works, Upton Street Gloucester, United Kingdom GL1 4LA Tests verified by independent laboratories. Actual roof performance specifications will vary depending on test speed and temperature. Data reflects samples randomly collected. A ± 10% variation may be experienced. The above data supersedes all previously published information. Consult your local Garland Representative or Garland Corporate Office for more information Garland Industries, Inc. ST 0212

4 Tuff-Stuff MS One-Part Elastomeric Adhesive Sealant Tuff-Stuff MS is a moisture-curing, single-component, non-sag, adhesive sealant that contains no solvents. When cured Tuff- Stuff MS offers the performance of a two-part sealant with the ease of installation associated with a one-part. It is designed to maintain an effective bond and seal between materials of similar and dissimilar surfaces, porosities and coefficients of expansion. Tuff-Stuff MS is designed for use in reglets, precast panels, tilt-up walls, metal curtain walls, copings, window and door perimeters, panel bedding and glazing details. PRODUCT ADVANTAGES Low Odor - Due to its modified silane chemistry, Tuff-Stuff MS is a low-odor product which makes it useful in VOC sensitive areas like hospitals, schools, and food production plants. Extended Life for High Movement - Tuff-Stuff MS high solid content optimizes minimal shrinking unlike heavily solvent based products which will shrink when exposed to UV as the solvent flashes out enabling high flexibility and long-term performance. Environmentally Safe - Tuff-Stuff MS does not use solvents or isocyanates and only contains 19 grams of VOC s per liter. User Friendly/Saves Money - Tuff-Stuff MS can be applied with a normal caulking gun, industrial type, and wet or dry tooled into a joint making it easy for in-house maintenance use. Cures Quickly - Tuff-Stuff MS utilizes a moisture assisted cure type chemistry which enables a fast skin time and is paintable within 3 days of install depending on the sealed joints overall dimensions. INSTALLATION Surface Preparation - Joint surfaces and backer rod must be dry and free of all contaminants such as oil, grease, wax, dust, corrosion, tar, asphalt, loose aggregate, frost, form-release agents, decorative and protective coatings. Precast panels using form release agents other than polyethylene film must be sandblasted or mechanically abraded and blown or brushed dust free. Glass, metal and other nonporous surfaces must be free of any coatings and wiped clean with solvent. Priming - Never a substitute for proper surface preparation, priming is not required on glass or anodized aluminum and usually not necessary on other common building materials. However, varieties of brick, natural stone, plastics, paints, EIFS, coatings and other treatments of surfaces often present difficult substrates at which to adhere. Due to the number and unpredictable nature of these substrates, a field test is recommended to determine the adhesion of Tuff-Stuff MS. Because architectural stones such as marble and granite vary considerably in porosity, some bleeding of the sealant into the substrate is a possibility. A field test to confirm this possibility is recommended. Joint Backing - Backer rods control the depth of the sealant and allows it to be applied under pressure. Use a size that will compress 25%. Open-cell polyurethane or reticulated (soft) polyethylene rod is recommended. Closed-cell polyethylene may be used but care must be taken not to puncture the rod, which can cause outgassing or bubbling/blistering in the sealant. In joints too shallow for backer rod, use a polyethylene bondbreaker tape to prevent three-sided adhesion. Joints should be masked to ensure a neat appearance. Sealant should be applied in a continuous operation using sufficient pressure to fill the joint and make complete contact to the joint sides. Tool the sealant slightly concave using dry-tooling techniques. Do not tool with soap or detergent and water solutions. Joint Design - The width of the joint should be a minimum of four (4) times the anticipated movement. The width or depth of the joint should not be less than 1/4 in. (6 mm). In joints up to 3/8 in. (9 mm) wide, the depth of the sealant should be equal to the width. In joints wider than 3/8 in. (9mm), but not exceeding 1-1/4 in. (31 mm), the depth should be maintained at 3/8 in. (9 mm). For joints wider than 1-1/4 in. (31 mm), please consult Garland s Technical Services Department. Movement Capability - 25% Extension - 25% Compression. Joint sealants do not change volume with expansion or compression, only shape; the greater the change in shape, the greater the stress on the sealant. Tool Time (Initial Skin) hours at 77 F (25 C); 50% relative humidity. Higher temperatures and/or humidity will shorten this time. Cleaning - Use mineral spirits to remove excess sealant before it cures and to clean equipment. Storage Life - One-part MS polymer is extremely moisture and heat sensitive. Tuff-Stuff MS has a warranted shelf life of nine (9) months from the factory shipping date when stored in original unopened cartridges at conditions not exceeding 80 F (27 C), 50% relative humidity. Consistently higher temperatures and/or humidity will shorten the shelf life and valid warranty.

5 Tuff-Stuff MS One-Part Elastomeric Adhesive Sealant Bond Durability-Class 25 (ASTM C 920) Hardness, Shore A (ASTM C 920, 15-50) Tuff-Stuff MS Passes Service Temperature Range -50 F to 300 F (-45 C to 148 C) Stain and Color Change (ASTM C 920) Tack Free 77 F (25 C); 50% RH (ASTM C 679) Tensile Strength Elongation Weep and Sag max 3/16 in. (4 mm) (ASTM C 920) VOC Colors Passes Less than 1 hr. 225 psi % Passes 19 g/l Refer to color chart For specific recommendations and coverage rates, please contact your local Garland Representative or Garland Technical Service Department. Coverage Joints Size Depth x Width 3/8 in. x 1/4 in. (.95 cm x.63 cm) 3/8 in. x 1/2 in. (.95 cm x 1.27 cm) 3/8 in. x 5/8 in. (.95 cm x 1.60 cm) 3/8 in. x 3/4 in. (.95 cm x 1.90 cm) 3/8 in. x 7/8 in. (.95 cm x 2.24 cm) 3/8 in. x 1 in. (.95 cm x 2.54 cm) 3/8 in. x 1 1/4 in. (.95 cm x cm) Shelf Life Packaging LIMITATIONS Tuff-Stuff MS should not be used: As a cap, heel or toe bead in certain glazing installations with high-performance glass or plastic In joints less than 1/4 in. (6 mm) in depth In joints where contact may be made with polysulfide sealants In areas exposed to harsh chemicals Tuff-Stuff MS Lineal ft. (m) per 10.1 oz ft. (4.93 m) 8.0 ft. (2.43 m) 6.4 ft. (1.94 m) 5.4 ft. (1.64 m) 4.6 ft. (1.40 m) 4.0 ft. (1.22 m) 3.2 ft. (.97 m) 9 months 10.3 oz. (305 ml) cartridges 24 cartridges per case On certain architectural paints and finishes without laboratory or field testing In horizontal joints subject to vehicular traffic unless protected by a wearing surface or cap pass of sealant. Garland Canada Inc. The Garland Company UK, LTD Unit 10b Mercia Road Gloucester, United Kingdom GL1 2SQ Tests verified by independent laboratories. Actual roof performance specifications will vary depending on test speed and temperature. Data reflects samples randomly collected. A ± 10% variation may be experienced. The above data supersedes all previously published information. Consult your local Garland Representative or Garland Corporate Office for more information. Garland Greenhouse and Tuff-Stuff are trademarks of 2015 Garland Industries, Inc. Tuff-Stuff MS 0615

6 White-Knight Plus White-Knight Plus White-Knight Plus WC White-Knight Plus is an ENERGY STAR qualified, highly reflective multi-purpose, single-component, aliphatic urethane liquid waterproofing membrane designed to maintain, restore and upgrade the performance of existing, aged single-ply, metal, smooth BUR, and modified bitumen roof systems. It provides a white reflective surface. The White-Knight Plus WC formula is VOC compliant and meets South Coast AQMD standards. PRODUCT ADVANTAGES Energy Efficient - Provides added UV protection to prolong the life of the roof, while helping maintain internal temperatures and reducing cooling costs. Waterproofing Protection - The White-Knight Plus system will provide wet mils (26 53 dry mils) of additional waterproofing protection to an existing roof system. This process will effectively extend the life of the roof system and allow reasonable time to budget for replacement or recoat. UV Resistant - This high-performance aliphatic urethane coating protects the existing roof from the harmful effects of UV, greatly reducing thermal shock. The coating itself is UV resistant due to its aliphatic chemistry. Chemical Resistant - White-Knight Plus is uniquely formulated to provide superior chemical resistance to many oils, acids, and other contaminants. Contact your local Garland Representative for specific chemicals and concentration levels. User Friendly - The ease of application makes White-Knight Plus extremely fast and simple to install. This superior coating can be used to reinforce, without additional reinforcing fabrics and seal laps, make spot repairs, or restore entire roofing systems. USES White-Knight Plus system can be used to coat an entire aged single-ply, metal, smooth BUR, and modified bitumen roof system. It can also be used as a repair material for maintenance applications. White-Knight Plus can be applied by brush, roller or spray. bonded. Prior to coating any surface, be sure the White-Knight Plus Base Coat will adhere by performing an adhesion test (ASTM D 903). Proper coverage rate is critical to the success of all coating projects. Use a wet mil gauge to ensure proper coverage rates. Single-Ply Restoration System - Power wash the entire surface including flashings with TSP or Simple Green and then thoroughly rinse, paying special attention to drains and low spots. The first coat of White-Knight Plus Base Coat should be applied at approximately 32 wet mils stripped in over all seams, flashings, and repaired areas. Any repaired areas must use cured membranes for the repairs. Allow roof system to dry for hours but no more than 72 hours. In the field of the roof, apply an additional 2 gal./100 sq. ft. (0.82 l/m 2 ) of White-Knight Plus (32 wet mils). The first layer may still be tacky at 24 hours; this is normal. Modified/BUR Restoration System - Power wash the entire surface including flashings with TSP or Simple Green. Allow roof system to dry for hours, then prime the entire roof surface with All-Knight Primer at a rate of 1/2 gal./100 sq. ft. (0.21 l/m 2 ). For the field of the roof and flashings, apply 2 gal./100 sq. ft. (0.82 l/m 2 )of White-Knight Plus Base Coat (32 wet mils). Allow roof system to dry for hours but no more than 72 hours. In the field of the roof, apply an additional 2 gal./100 sq. ft. (32 wet mils) of White-Knight Plus (0.82 l/m 2 ). The first layer may still be tacky at 24 hours; this is normal. Metal Restoration System - Power wash the entire surface including flashings with TSP or Simple Green. When coating a metal surface, all rust must be removed and then treated. All surfaces must be sound, dry, clean, and free of oil, dirt, grease, wax, mildew, loose or flaking paint and rust by scraping, sanding, wire brushing or blasting. Apply White-Knight Metal Primer over a small area at 1/4 gal./100 sq. ft. (0.11 l/m 2 ) and let set for twenty (20) minutes. Monitor to ensure adhesion and note if sag occurs. If any sag occurs, adjust coverage as necessary. Once adhesion is confirmed, then apply White-Knight Metal Primer over the entire surface at 1/4 gal./100 sq. ft. (0.11 l/m 2 ). The first coat of White-Knight Plus Base Coat should be applied at approximately 2 gal./100 sq. ft. (0.82 l/m 2 ), 32 wet mils, stripped in over all seams, around penetrations, and fasteners. Allow roof system to dry for hours but no more than 72 hours. Next, install the finish coat of White-Knight Plus at 2 gal./100 sq. ft. (0.82 l/ m 2 ) over the entire roof (32 wet mils). The first layer may still be tacky at 24 hours; this is normal. Restoration Overview - Ensure that all wet insulation is removed. An infrared scan is highly recommended. Remove all dirt, dust, and debris from the roof surface. Make any necessary repairs and also verify that all repairs are securely

7 White-Knight Plus White-Knight Plus White-Knight Plus WC Tensile Strength Tear Resistance (ASTM D 624) Elongation 77 F (25 C) (ASTM D 2939) Flash Point (ASTM D 93) Non-Volatile (ASTM D 75) 77 F (25 C); 10 rpm Brookfield RVT, #4 Spindle Shelf Life Wet Film Coverage Single-ply Basecoat (seams) Modified/BUR Basecoat (entire roof) Metal Basecoat (seams) Packaging White-Knight Plus & White-Knight Plus WC 2100 psi 160 lbs./in 320% 10.4 lb./gal (1.2 g/m 3 ) 110 F min. (43 C) Typical 83% 9200 cp 1 yr. (unopened container) 32 mils (812.8 micros) 5 gallon (18.9 l) pail 55 gallon (208.2 l) drum Eco-Facts White-Knight Plus White-Knight Plus WC VOC 225 g/l 50 g/l Reflectance Emittance SRI PRECAUTIONS Do not apply when temperatures are below 40 F (4.4 C) or if rain is in the forecast within 48 hours. Spray application is not recommended below 50 F (10 C) In areas where the roof is subject to foot traffic, it is recommended to apply a granule walkway surface Excess water on the roof surface can cause the roof to become slippery If spraying, consult the White-Knight/White-Stallion Plus Spray Application Guide Prior to coating any surface, be sure the coating will adhere by performing an adhesion test (ASTM D 903) Not intended to restore glaze coats of asphalt A reinforcement fabric should be used when coating over heavily alligatored areas, areas that pond water, and over any type of surface irregularities For specific application recommendations and coverage rates, please contact your local Garland Representative or Garland Technical Service Department. Approval does not apply to WC version RATED PRODUCT Garland Canada Inc. The Garland Company UK, LTD Unit 5 Glevum Works, Upton Street Gloucester, United Kingdom GL1 4LA Tests verified by independent laboratories. Actual roof performance specifications will vary depending on test speed and temperature. Data reflects samples randomly collected. A ± 10% variation may be experienced. The above data supersedes all previously published information. Consult your local Garland Representative or Garland Corporate Office for more information. White-Knight, All-Knight, and Garland Greenhouse are trademarks of ENERGY STAR is a registered trademark of the U.S. government. The ENERGY STAR program represents a voluntary partnership between businesses and organizations and the federal government to promote energy efficiency and environmental activities (Valid in the U.S. Only). The CRRC mark is a registered trademark of the Cool Roof Rating Council Garland Industries, Inc. WK Plus 0315

8 White-Knight /White-Stallion Metal Primer White-Knight /White-Stallion Metal Primer is a high-performance, single-component all-purpose, aromatic urethane, moisture curing primer for use where rust inhibiting and chemical corrosion resistance are required on metal systems. Its non-lifting properties make it an ideal primer to use with urethane topcoats. White-Knight/White-Stallion Metal Primer has excellent corrosion resistance and should be used as a primer surface with the White-Knight/White-Stallion coating system when used over metal substances. PRODUCT ADVANTAGES Durable - White-Knight/White-Stallion Metal Primer has excellent adhesion to properly prepared metal surfaces. Its resistance to mild industrial fumes and light chemical conditions make it an excellent primer in a restoration coating system. User Friendly - The ease of application makes White-Knight/ White-Stallion Metal Primer fast and simple to install. This primer can be used over a variety of properly prepared metal substrates. Seals & Conditions - White-Knight/White-Stallion Metal Primer combined with the White-Knight/White-Stallion coating system offers the customer the opportunity to protect and to preserve their investments before the roof needs to be replaced due to oxidation and rust. Protect & Maintain - The White-Knight/White-Stallion Metal Primer is designed to maintain and protect metals from rusting and breaking down, while giving you a clean surface for your coating system. USES White-Knight/White-Stallion Metal Primer is used as a primer with the White-Knight/White-Stallion or White-Knight Plus/ White-Stallion Plus coating systems on metal roof systems. It is designed for application to steel, galvanized, galvalume, kynar coated, copper, aluminum, and stainless steel metal roof systems. SURFACE PREPARATION Wearing protective clothing, gloves and glasses, remove any mildew by washing with a solution of three quarts of warm water and TSP or Simple Green solution. It is important to rinse thoroughly to remove any residue left by the cleaner. Repair gaps, holes and joints in the metal roof with appropriate patching materials. Dull all glossy surfaces by sanding to assure maximum adhesion. Wipe galvanized surfaces clean with MEK prior to application. For optimum surface preparation, grit blasting is recommended. Please contact Garland Technical for various substrates when grit blasting is permitted. All surfaces should be cleaned and degreased prior to grit blasting with organic solvents, caustic solutions, or pressure washing with a solution of TSP or Simple Green (2500 psi recommend). NOTE: A spray nozzle of 15 degrees or greater will help eliminate pin point penetration and ensure water does not penetrate the substrate or interior of the structure. Kynar Coated Metal - Recommended 80 mesh or finer grit abrasive. Then wipe surface with solvent. New Galvanized Steel or Galvalume - Brush blast using caution not to remove galvanizing. The surface should be prepared to a SSPC-SP-7 or Nace No. 4 brush blast specification. Steel - The surface should be grit blasted to an SSPC-SP-6 or Nace No. 2 commercial blast. The finish should be free of loose mill scale, rust scale and old coatings. Stainless Steel - There are various types of stainless steel, including 304 (the softest), 316, 316 L, and 904. Use a 120 psi blast nozzle. Do not grit blast with iron or steel grit abrasives. Aluminum - Recommended 80 mesh or finer grit abrasive. Copper - Brush blasting to remove oxides. Follow specifications of SSPC-SP-7 or Nace No. 4 surface preparation. All surfaces must be sound, dry, clean and free of oil, dirt, grease, wax, mildew, loose or flaking paint and rust by scraping, sanding, wire brush or blasting. Mix for 5 minutes before application, ensuring that the product is an even color. Then, apply White-Knight/White-Stallion Metal Primer over a small area at 1/4 gal/100 sq. ft. (0.11 l/m 2 ) and let set for 3 hours before applying top coat. Monitor to ensure adhesion and note if sag occurs. If any sag occurs, adjust coverage as necessary.

9 White-Knight/White-Stallion Metal Primer Brush & Roller - Apply with synthetic brush or roller (short nap) of appropriate size and/or nap for the surface being painted. Spray - Consult the White-Knight/White-Stallion Metal Primer Spray Application Guide. Flash Point (ASTM D 93) White-Knight/White-Stallion Metal Primer 107ºF (41.6ºC) Note: The primer must be top coated within 48 hours of application. If 48 hours passes without being top coated, then the primer must be lightly sanded with an 80 grit paper to rough the surface up. SAFETY It is good practice to wear chemical splash goggles to avoid contact with eyes. Avoid prolonged contact with skin. Wash thoroughly after handling. See Material Safety Data Sheet for additional safety information and specific product analysis. PRECAUTIONS Do not apply when temperatures are below 40 F (4.4 C) Not recommended for use when there is a 40% chance of rain in the forecast Must be top coated within 48 hours of application Not recommended for use on lead roof systems Prior to coating any surface, be sure the coating will adhere by performing an adhesion test Use low-speed mixing equipment to avoid inducing moisture into the primer Solids by Volume 50% Dry 77 F (25 C) 50 RH To Touch To Tack Free To Top Coat Shelf Life Color Clean up Wet Film 1/4 gal. (0.94 l) Dry Mil Coverage 45 min. 1.5 hours 3 hours 12 months in an unopened container Non-leafing aluminum Lacquer Thinner 4 mils (101.6 microns) 2 mils (50.8 microns) 1/4 gal/100 sq. ft. (0.11 l/m 2 ) Packaging 3 gallon pail (10.6 l) Eco-Facts VOC White-Knight/White-Stallion Metal Primer 410 g/l For specific recommendations and coverage rates, please contact your local Garland Representative or Garland Technical Service Department. Garland Canada Inc. The Garland Company UK, LTD Unit 5, Glevum Works, Upton Street Gloucester, United Kingdom GL1 4LA Tests verified by independent laboratories. Actual roof performance specifications will vary depending on test speed and temperature. Data reflects samples randomly collected. A ± 10% variation may be experienced. The above data supersedes all previously published information. Consult your local Garland Representative or Garland Corporate Office for more information. Kynar is a registered trademark of Arkema Inc. White-Knight is a trademark of and The Garland Company UK, LTD. White-Stallion is a trademark of Garland Canada Inc Garland Industries, Inc. WK WS MP 0314

10 White-Knight /White-Stallion Plus Base Coat White-Knight/White-Stallion Plus Base Coat is a gray, multi-purpose, single-component aliphatic urethane, liquid waterproofing membrane, designed as the initial layer of a White-Knight/White-Stallion Plus system to maintain, restore and upgrade the performance of existing, aged single-ply, metal, smooth BUR, and modified bitumen roof systems. PRODUCT ADVANTAGES Waterproofing Protection - White-Knight/White-Stallion Plus Base Coat will provide 32 wet mils (26 dry mils) of additional waterproofing protection to an existing roof system as just a base coat. This process will effectively extend the life of the roof system and allow reasonable time to budget for replacement or recoat. UV Resistant - This high performance aliphatic urethane coating protects the existing roof from the harmful effects of UV, greatly reducing thermal shock. The coating itself is UV resistant due to its aliphatic chemistry. User Friendly - The ease of application makes White-Knight/ White-Stallion Plus Base Coat extremely fast and simple to install. This superior coating can be used to reinforce and seal laps, make spot repairs or restore entire roofing systems. USES White-Knight/White-Stallion Plus Base Coat can be used to coat an entire aged single-ply, metal, smooth BUR, and modified bitumen roof system. It can also be used as a repair material for maintenance applications. It is designed to be the base coat in the White-Knight/White-Stallion Plus system. White-Knight/White-Stallion Plus can be applied by brush, roller or spray. Restoration Overview - Ensure that all wet insulation is removed. An infrared scan is highly recommended. Remove all dirt, dust, and debris from the roof surface. Make any necessary repairs and also verify that all repairs are securely bonded. Prior to coating any surface, be sure the coating will adhere by performing an adhesion test (ASTM D 903). Proper coverage rate is critical to the success of all coating projects. Use a wet mil gauge to ensure proper coverage rates. Single-Ply Restoration System - Power wash the entire surface including flashings with TSP or Simple Green and then thoroughly rinse. The first coat of White-Knight/White- Stallion Plus Base Coat should be applied at approximately, 32 wet mils, stripped in over all seams, flashings, and repaired areas. Allow roof system to dry for hours but no more than 72 hours. In the field of the roof, apply an additional 2 gal./ 100 sq. ft. (0.82 l/m 2 ) for the finish coat (32 wet mils). The first layer may still be tacky at 24 hours; this is normal. Modified/BUR Restoration System - Power wash the entire surface including flashings with TSP or Simple Green. Allow roof system to dry for hours, then prime the entire roof surface with All-Knight /All-Stallion Primer at a rate of 1/2 gal./100 sq. ft. (0.21 l/m 2 ). For the field of the roof and flashings, apply of White- Knight/White-Stallion Plus Base Coat (32 wet mils). Allow roof system to dry for hours but no more than 72 hours. In the field of the roof, apply an additional 2 gal./100 sq. ft. (0.82 l/ m 2 ) for the finish coat. The first layer may still be tacky at 24 hours; this is normal. Metal Restoration System Power wash the entire surface including flashings with TSP or Simple Green. When coating a metal surface, all rust must be removed and then treated. All surfaces must be sound, dry, clean, and free of oil, dirt, grease, wax, mildew, loose or flaking paint, and rust by scraping, sanding, wire brushing or blasting. Apply White-Knight/White-Stallion Metal Primer over a small area at 1/4 gal./100 sq. ft. (0.11 l/m 2 ) and let set for twenty (20) minutes. Monitor to ensure adhesion and note if sag occurs. If any sag occurs, adjust coverage as necessary. Once adhesion is confirmed, then apply White-Knight/White-Stallion Metal Primer over the entire surface at 1/4 gal./100 sq. ft. (0.11 l/m 2 ). The first coat of White-Knight/White-Stallion Plus Base Coat should be applied at approximately 2 gal./100 sq. ft. (0.82 l/ m 2 ), 32 wet mils, stripped in over all seams, around penetrations, and fasteners. Allow roof system to dry for hours but no more than 72 hours. Next, install the finish coat at 2 gal./100 sq. ft. (0.82 l/m 2 ) over the entire roof (32 wet mils). The first layer may still be tacky at 24 hours; this is normal.

11 White-Knight /White-Stallion Plus Base Coat Tensile Strength Tear Resistance (ASTM D 624) Elongation 77 F (25 C) (ASTM D 2939) Flash Point (ASTM D 93) Non-Volatile (ASTM D 75) 77 F (25 C); 10 rpm Brookfield RVT, #4 Spindle Shelf Life Wet Film 2 gal./100 sq. ft. (0.82 l/m 2 ) Color Coverage Single-ply Basecoat (seams) Modified/BUR Basecoat (entire roof) Metal Basecoat (seams) Packaging White-Knight/White-Stallion Plus Base Coat 2100 psi 160 lbs./in. 320% 10.4 lbs./gal. (1.2 g/cm 3 ) 110 F (44 C) Typical 83% 9,100 cp 1 yr. (unopened container) 32 mils (812.8 micros) Gray 5 gallon (18.9 l) pail 55 gallon (208.2 l) drum Eco-Facts VOC PRECAUTIONS White-Knight/White-Stallion Plus Base Coat 225 g/l Do not apply when temperatures are below 40 F (4.4 C) or if rain is in the forecast. Spray application is not recommended below 50 F (10 C) In areas where the roof is subject to foot traffic, it is recommended to apply a granule walkway surface Excess water on the roof surface can cause the roof to become slippery If spraying, consult the White-Knight/White-Stallion Plus spray application guide Prior to coating any surface, be sure the coating will adhere by performing an adhesion test (ASTM D 903) Not intended to restore glaze coats of asphalt A reinforcement fabric should be used when coating over heavily alligatored areas or any type of surface irregularities For specific application recommendations and coverage rates, please contact your local Garland Representative or Garland Technical Service Department. Garland Canada Inc. The Garland Company UK, LTD Unit 5 Glevum Works, Upton Street Gloucester, United Kingdom GL1 4LA Tests verified by independent laboratories. Actual roof performance specifications will vary depending on test speed and temperature. Data reflects samples randomly collected. A ± 10% variation may be experienced. The above data supersedes all previously published information. Consult your local Garland Representative or Garland Corporate Office for more information. White-Knight and All-Knight are trademarks of White-Stallion and All-Stallion are trademarks of Garland Canada Inc Garland Industries, Inc. WK/WS PLUS BASE COAT 0712

MAKE ROOFS LAST LONGER

MAKE ROOFS LAST LONGER MAKE ROOFS LAST LONGER Roof Coatings & Roof Repair Single-Ply Metal Asphalt HIGHEST PERFORMING SYSTEMS. LOWEST APPLIED COST. METAL ROOF RESTORATION Metal Restoration Quick Guide Acrylic Polyurethane High

More information

838 Coatings System Specification Single-Ply Restoration (838 SPR)

838 Coatings System Specification Single-Ply Restoration (838 SPR) 838 Coatings System Specification Single-Ply Restoration (838 SPR) PART 1 General 1.01 System Description The 838 Single-Ply Restoration System (838 SPR) can be applied to a variety of single-ply manufactures.

More information

ROCK-IT XC TECHNICAL DATA SHEET

ROCK-IT XC TECHNICAL DATA SHEET ROCK-IT XC TECHNICAL DATA SHEET DESCRIPTION Rock-It XC is a high quality, urethane, textured coating that provides a durable, chemical and fade resistant, protective finish for truck beds, recreational

More information

ROCK-IT XC TECHNICAL DATA SHEET

ROCK-IT XC TECHNICAL DATA SHEET ROCK-IT XC TECHNICAL DATA SHEET Check local VOC DESCRIPTION Rock-It XC is a high quality, urethane, textured coating that provides a durable, chemical and fade resistant, protective finish for truck beds,

More information

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com TOPCOAT Restoration Specifications

More information

TRUCKBED LINER TECHNICAL DATA SHEET

TRUCKBED LINER TECHNICAL DATA SHEET TRUCKBED LINER TECHNICAL DATA SHEET DESCRIPTION Truckbed Liner is a two component, urethane, textured coating that provides superior adhesion, film build and flexibility to truckbeds and restoration projects.

More information

Technical Bulletin 2400 Boston Street, Suite 200, Baltimore, Maryland Phone: or

Technical Bulletin 2400 Boston Street, Suite 200, Baltimore, Maryland Phone: or Technical Bulletin 2400 Boston Street, Suite 200, Baltimore, Maryland 21224 Phone: 410-675-2100 or 800-543-3840 Revised: 1/28/2016 DAP 3.0 High Performance Gutter & Flashing Sealant Wet or dry surface

More information

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL Part 1. 1.1 Description General Conditions A. Scope of Work Provide all materials, labor and equipment required for the installation

More information

EFFISUS EASYREPAIR MEMBRANE

EFFISUS EASYREPAIR MEMBRANE Effisus Easyrepair Membrane EFFISUS EASYREPAIR MEMBRANE DESCRIPTION For use on virtually all roofs, Effisus Easyrepair Membrane features an UV stable backing that is available in Black, Gray, Tan, and

More information

Pacific Polymers Elasto-Deck 5000MR Guide Specification

Pacific Polymers Elasto-Deck 5000MR Guide Specification 1 071813-1 July 2018 Pacific Polymers Elasto-Deck 5000MR Guide Specification SECTION 071813 TRAFFIC COATINGS ELASTO-DECK 5000MR OVER CONCRETE 2 071813-2 July 2018 Pacific Polymers Elasto-Deck 5000MR Guide

More information

FireShield Restoration Specifications - EPDM

FireShield Restoration Specifications - EPDM FireShield Restoration Specifications - EPDM Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com FIRESHIELD Restoration Specifications EPDM PART 1 GENERAL

More information

- TECHNICAL DATA SHEET

- TECHNICAL DATA SHEET MAKERS OF ADHESIVES, SEALANTS, AND RELATED PRODUCTS SINCE 1958. Multiflex (Co-Polymer Sealant - TECHNICAL DATA SHEET pg1 Phone: (403) 252-7803 Fax: (403) 2522384 www.chemtron.ca - TECHNICAL DATA SHEET

More information

Easy to apply Nonflammable Low odor Castable Make excellent materials of construction

Easy to apply Nonflammable Low odor Castable Make excellent materials of construction SELECTION & SPECIFICATION DATA Generic Type Description Features Color Primer Application Thickness Dry Film Thickness Typical Uses Polymer Concrete polymer concrete is an excellent alternative to acid

More information

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

Pacific Polymers Elasto-Deck 5000X2 Guide Specification 1 071813-1 July 2018 Pacific Polymers Elasto-Deck 5000X2 Guide Specification SECTION 071813 TRAFFIC COATINGS ELASTO-DECK 5000X2 OVER CONCRETE 2 071813-2 July 2018 Pacific Polymers Elasto-Deck 5000X2 Guide

More information

Refer to Substrates & Surface Preparation.

Refer to Substrates & Surface Preparation. SELECTION & SPECIFICATION DATA Generic Type Description Features Color Finish Primer Dry Film Thickness Aliphatic Acrylic Polyurethane Thin film, high gloss finish with exceptional weathering performance

More information

CARLISLE DECK COATING INSTALLATION OVER EXISTING POLYURETHANE COATINGS

CARLISLE DECK COATING INSTALLATION OVER EXISTING POLYURETHANE COATINGS CARLISLE DECK COATING INSTALLATION OVER EXISTING POLYURETHANE COATINGS 1. GENERAL A. When coating over existing coatings, Carlisle can not assume responsibility for the adhesion of the existing coating,

More information

URETHANE. Asphalt Restoration Aged BUR and Modified Bitumen Sample Design Guideline

URETHANE. Asphalt Restoration Aged BUR and Modified Bitumen Sample Design Guideline 1 DG0001-J 05/2017 Asphalt Restoration Aged BUR and Modified Bitumen Sample Design Guideline URETHANE ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving, TX 75060 Tel: 972-438-9111 Fax:

More information

EFFISUS STOPPER M-1 SEALANT

EFFISUS STOPPER M-1 SEALANT EFFISUS STOPPER M-1 SEALANT DESCRIPTION is a moisture curing, polyether adhesive/sealant designed for application in damp, dry, or cold climates. is solvent free and contains no isocyanates. will not shrink

More information

GULF COAST PAINT MFG., INC

GULF COAST PAINT MFG., INC MCU-100 PRIMER/FINISH MOISTURE CURED URETHANE ALUMINUM COATING PRODUCT DESCRIPTION A one component, Moisture Cured Polyurethane Aluminum Coating. Has excellent adhesion to sound, tightly adherent rusty

More information

TYPICAL UNCURED PROPERTIES*

TYPICAL UNCURED PROPERTIES* Bostik Chem-Calk 955-SL Chem-Calk 955-SL is a one-component, self- leveling polyurethane sealant capable of dynamic joint movement totaling 50% of original joint geometry (±25%). The sealant cures to a

More information

Asphalt Maintenance PRODUCTS INFORMATION AND INSTALLATION GUIDE

Asphalt Maintenance PRODUCTS INFORMATION AND INSTALLATION GUIDE Asphalt Maintenance PRODUCTS INFORMATION AND INSTALLATION GUIDE TABLE OF CONTENT About RESISTO 2 Asphalt Cleaner and Degreaser 3 Oil Spot Primer 3 Liquid Crack Filler 4 Rubberized Crack Filler 4 Levelling

More information

Data Sheet Eco-Smart Membrane WS M1

Data Sheet Eco-Smart Membrane WS M1 Water-based Acrylic WS M1 Elastomeric Waterproofing Membrane is a durable, multi-use, extremely durable acrylic coating. At an ideal wet film thickness of 10-14 mils per coat (8-10 mils dry film finish

More information

ACRYLIC Elastek #127 Solar One Plus

ACRYLIC Elastek #127 Solar One Plus 1 EL0017-L 01/2018 AGED (EPDM, TPO, CSPE-HYPALON, PIB) SINGLE-PLY (THERMOSET) MEMBRANE RESTORATION SYSTEM APPLICATION SAMPLE DESIGN GUIDELINE ACRYLIC Elastek #127 Solar One Plus ITW POLYMERS SEALANTS NORTH

More information

TL-280 Sprayable Flake Glass Vinyl Ester Lining System

TL-280 Sprayable Flake Glass Vinyl Ester Lining System TL-280 Sprayable Flake Glass Vinyl Ester Lining System PRODUCT DESCRIPTION TL-280 is a high performance, flake glass vinyl ester lining system, utilizing carefully selected and sized glass flake reinforcement

More information

Sanitile 945 SL PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. 100% solids epoxy

Sanitile 945 SL PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. 100% solids epoxy SELECTION & SPECIFICATION DATA Generic Type Description Features 100% solids epoxy Sanitile 945 SL is a 100% solids, high performance, epoxy coating designed for concrete. Sanitile 945 SL is a selfleveling

More information

A. Submit product data sheets and literature verifying physical properties of materials.

A. Submit product data sheets and literature verifying physical properties of materials. I. GENERAL ACRYSHIELD ROOF MANAGEMENT SYSTEM Installation Guide Specification For Preserving EPDM Roofs 07500 Saving Money, Safeguarding the Environment One Roof at a Time. 1.01 SUMMARY A. Provide labor,

More information

Dist. by: BEST MATERIALS Ph:

Dist. by: BEST MATERIALS Ph: Dist. by: BEST MATERIALS Ph: 800-474-7570 www.bestmaterials.com Email: Sales@BestMaterials.com NOVALINK SL SELF-LEVELING CONSTRUCTION SEALANT DIVISION 7 - THERMAL AND MOISTURE PROTECTION SECTION 07 92

More information

BENEFITS & ADVANTAGES:

BENEFITS & ADVANTAGES: APPLICATION GUIDELINES The following KARNAK Roof Restoration System is intended to be applied over sound metal roofing systems with a weathered Kynar coated metal finish. BENEFITS & ADVANTAGES: Elastomeric

More information

Application Specification:

Application Specification: Application Specification: MR-30-GF20 March 2014 Supersedes 10/11 PART 1 - GENERAL 1.1 SUMMARY DIVISION 07 01 50.61: GACO WESTERN GACOFLEX S-20 ELASTOMERIC SILICONE COATING FOR REHABILITATION OF AGED METAL

More information

CIM IG 13 11/06. Instruction Guide

CIM IG 13 11/06. Instruction Guide 23 Elm St., Peterborough, NH 03458 Tel: (800) 543-3458 (603) 924-9481 Fax: (603) 924-9482 Web site: Instruction Guide APPLICATION OF CIM 2000 TO CONCRETE 1.0 DESCRIPTION This guide covers the installation

More information

Technical Data Sheet NUKOTE SIL HS DESCRIPTION:

Technical Data Sheet NUKOTE SIL HS DESCRIPTION: DESCRIPTION: Nukote SIL HS is a single-component silicone elastomer specifically designed as Cool Roof Tope/Base Coats. It is a pure elastomeric silicone coating system that provides superior weatherproofing,

More information

Ev erguard Adhesiv es Guid e. Updated: 3/ 17

Ev erguard Adhesiv es Guid e. Updated: 3/ 17 Ev erguard Adhesiv es Guid e Updated: 3/ 17 INSULATION ADHESIVES is a two-component polyurethane low-rise foam adhesive used to adhere a variety of board stocks to most roof substrates or other insulation

More information

Technical Bulletin Boston Street, Suite 200, Baltimore, Maryland Phone: or

Technical Bulletin Boston Street, Suite 200, Baltimore, Maryland Phone: or Technical Bulletin 2400 Boston Street, Suite 200, Baltimore, Maryland 21224 Phone: 410-675-2100 or 800-543-3840 Revised: 1/28/16 DAP 3.0 High Performance Window, Door, Trim & Siding Sealant Meets ASTM

More information

Application Specification:

Application Specification: Application Specification: MR-38-GF20 May 2014 Supersedes 10/11 PART 1 - GENERAL 1.1 SUMMARY DIVISION 07 01 50.61: GACO WESTERN GACOFLEX S-20 ELASTOMERIC SILICONE COATING FOR REHABILITATION OF AGED METAL

More information

TL-225-NS Teflon Filled, Vinyl Ester Coating & Lining

TL-225-NS Teflon Filled, Vinyl Ester Coating & Lining TL-225-NS Teflon Filled, Vinyl Ester Coating & Lining PRODUCT DESCRIPTION TYPICAL USES APPLICATION METHODS Blome TL-225-NS is a Teflon filled, sprayable vinyl ester tank lining system. TL-225-NS offers

More information

BENEFITS & ADVANTAGES:

BENEFITS & ADVANTAGES: APPLICATION GUIDELINES WHITE REFLECTIVE The following KARNAK Roof Restoration System is intended to be applied over sound, dry, existing smooth built-up asphalt and smooth or granular modified bitumen

More information

DAP ALEX FAST DRY Acrylic Latex Caulk Plus Silicone

DAP ALEX FAST DRY Acrylic Latex Caulk Plus Silicone DAP ALEX FAST DRY Acrylic Latex Caulk Plus Silicone PRODUCT DESCRIPTION DAP ALEX FAST DRY ACRYLIC LATEX CAULK PLUS SILICONE is specifically formulated to meet the demanding needs of Professional Painters

More information

ACRYLIC. AGED (PVC, CPE, CPA) SINGLE-PLY (Thermoplastic) Membrane Restoration Sample Design Guideline

ACRYLIC. AGED (PVC, CPE, CPA) SINGLE-PLY (Thermoplastic) Membrane Restoration Sample Design Guideline 1 DG0013-J 04/2017 AGED (PVC, CPE, CPA) SINGLE-PLY (Thermoplastic) Membrane Restoration Sample Design Guideline ACRYLIC ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving, TX 75060 Tel:

More information

Commercial Moisture Cure Sealants

Commercial Moisture Cure Sealants Commercial Moisture Cure Sealants 8500 Silicone Sealant High-Solids Neutral Cure Oxime Silicone Sealant. Ideal for exterior joints, metal roofing, windows, siding and doors. Clear and White. 1 gal. pails*

More information

900HA is a two component, hand-applied seamless liquid waterproofing that is typically foottrafficable

900HA is a two component, hand-applied seamless liquid waterproofing that is typically foottrafficable 900HA (US Version) Fast-cure, hand-applied liquid waterproofing membrane Product Description 900HA is a two component, hand-applied seamless liquid waterproofing that is typically foottrafficable after

More information

Blome Sealant 55MT Flexible, Moisture-tolerant Epoxy Novolac Joint Sealant

Blome Sealant 55MT Flexible, Moisture-tolerant Epoxy Novolac Joint Sealant Blome Sealant 55MT Flexible, Moisture-tolerant Epoxy Novolac Joint Sealant PRODUCT DESCRIPTION Blome Sealant 55MT is a two-component, moisture-tolerant, 100% solids epoxy novolac elastomer with excellent

More information

URETHANE. CONCRETE ROOF WATERPROOFING SYSTEM Sample Design Guideline

URETHANE. CONCRETE ROOF WATERPROOFING SYSTEM Sample Design Guideline 1 DG0049-A 052017 CONCRETE ROOF WATERPROOFING SYSTEM Sample Design Guideline URETHANE ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving, TX 75060 Tel: 972-438-9111 Fax: 972-554-3939

More information

TOPCOAT System Specifications Corrugated Transite Panels

TOPCOAT System Specifications Corrugated Transite Panels TOPCOAT System Specifications Corrugated Transite Panels Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com TOPCOAT System Specifications Corrugated Transite

More information

TL-250 Glass Flake Filled, Vinyl Ester Tank Lining System

TL-250 Glass Flake Filled, Vinyl Ester Tank Lining System TL-250 Glass Flake Filled, Vinyl Ester Tank Lining System PRODUCT DESCRIPTION TL-250 is a Vinyl Ester Tank Lining system based on a glass flake filled, trowel-on base coat and a spray applied glass flake

More information

ChemMasters. Installation Guidelines

ChemMasters. Installation Guidelines ChemMasters Installation Guidelines Traz 25 is a state of the art, film forming concrete and masonry waterproofing sealer formulated with methyl methacrylate polymers. 1.0 General 1.1 Scope This specification

More information

MAINTENANCE & REPAIR SOLUTIONS

MAINTENANCE & REPAIR SOLUTIONS MAINTENANCE & REPAIR SOLUTIONS LOW-SLOPE ROOFING WE VE GOT WHAT YOU NEED IN THE SIZES YOU NEED THEM AND THE OPTIONS TO MATCH THE RESULTS THAT BUILDING OWNERS WANT SEAL-FAST TEMPORARY ROOF SEALER Now you

More information

APPLICATION GUIDELINE

APPLICATION GUIDELINE PROVEN ACRYLIC ROOFING SYSTEMdesigned to restore & protect metal roofs METAL To ensure warranty eligibility, each job must be approved by American WeatherStar before it begins. PART 1 GENERAL 1.01 DESCRIPTION

More information

Roof Repair Sealants

Roof Repair Sealants Roof Repair Sealants H.E.R. Flash Grade Polyurethane Sealant Quicket Self-Leveling Sealant 2100 MS Adhesive Sealant Silyl-Modified Adhesive Sealant Permathane 7108 Polyurethane Sealant HIGHEST PERFORMING

More information

Blome Sealant 55MT Flexible, Moisture-tolerant Epoxy Novolac Joint Sealant

Blome Sealant 55MT Flexible, Moisture-tolerant Epoxy Novolac Joint Sealant Blome Sealant 55MT Flexible, Moisture-tolerant Epoxy Novolac Joint Sealant PRODUCT DESCRIPTION Blome Sealant 55MT is a two-component, moisture-tolerant, 100% solids epoxy novolac elastomer with excellent

More information

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY SOLAR COATING SYSTEMS 2-PLY EMULSION MULSION/A /ACRYLIC SYSTEM Specification for Built-Up Roofing 07590 PART 1. GENERAL 1.01 SUMMARY Name Address City, State, zip A. Furnish and install a seamless, reinforced

More information

Application Specification:

Application Specification: Application Specification: MR-22-GF20 March 2014 Supersedes 10/11 PART 1 - GENERAL 1.1 SUMMARY DIVISION 07 01 50.61: GACO WESTERN GACOFLEX S-20 ELASTOMERIC SILICONE COATING FOR REHABILITATION OF AGED METAL

More information

ERSYSTEM ONESTEP PLUS

ERSYSTEM ONESTEP PLUS 1 DG0047-A 05/2017 AGED (EPDM, TPO, CSPE-HYPALON, PIB) SINGLE-PLY (THERMOSET) MEMBRANE RESTORATION SYSTEM APPLICATION SAMPLE DESIGN GUIDELINE ERSYSTEM ONESTEP PLUS ITW POLYMERS SEALANTS NORTH AMERICA,

More information

3,Rothwell Street, Timaru, South Canterbury. ; : Phone or

3,Rothwell Street, Timaru, South Canterbury.  ; : Phone or ECO-SEAL 100 3,Rothwell Street, Timaru, South Canterbury Email; ideaslab64@gmail.com : Phone +64 3 688 5508 or 0275 239888 Two Pack Flexible Self Priming high hysteresis waterproofing membrane designed

More information

BAYBLOCK HT/BAYBLOCK HT BASE

BAYBLOCK HT/BAYBLOCK HT BASE Characterization Properties / Applications Bayblock HT is a technologically advanced, high-solids, alkali resistant, thixotropic,acrylic elastomeric coating. Bayblock HT is formulated for the protection

More information

Copolymer BEFORE. Copolymer DURING. Copolymer AFTER. (800) TRI-CHEM 3

Copolymer BEFORE. Copolymer DURING. Copolymer AFTER.   (800) TRI-CHEM 3 Roof Repair Copolymer BEFORE Copolymer DURING Copolymer AFTER www.tri-chem.com (800) 456-6255 TRI-CHEM 3 TECHNICAL DATA SHEET TRI-MEMBRANE DESCRIPTION Tri-Membrane is an asphalt impregnated cotton membrane

More information

Bridge Preservation Product Advantages:

Bridge Preservation Product Advantages: Specializing in the rail and highway markets, Bridge Preservation manufactures high performance membrane systems designed to permanently protect rail and highway structures. These rapid setting high build

More information

Aliphatic Acrylic-Polyester Polyurethane

Aliphatic Acrylic-Polyester Polyurethane SELECTION & SPECIFICATION DATA Generic Type Description Features Color Finish Primer Dry Film Thickness Aliphatic Acrylic-Polyester Polyurethane High build, low sheen finish that has excellent resistance

More information

ROCK-IT LINER TM TECHNICAL DATA SHEET

ROCK-IT LINER TM TECHNICAL DATA SHEET ROCK-IT LINER TM TECHNICAL DATA SHEET Check local VOC DESCRIPTION Rock-It Liner is a high quality urethane textured coating that provides a durable protective finish for truckbeds and restoration projects.

More information

A. Submit product data sheets and literature verifying fire ratings and physical properties of materials.

A. Submit product data sheets and literature verifying fire ratings and physical properties of materials. I. GENERAL ACRYSHIELD ROOF MANAGEMENT SYSTEM Installation Guide Specification For Preserving BUR & Mod Bit Roofs 07560 Saving Money, Safeguarding the Environment One Roof at a Time. 1.01 SUMMARY A. Provide

More information

DIVISION 7 THERMAL AND MOISTURE PROTECTION Section Traffic Coatings

DIVISION 7 THERMAL AND MOISTURE PROTECTION Section Traffic Coatings Spec Component: SC-720-03/10 Sikalastic 720/745 Traffic System DIVISION 7 THERMAL AND MOISTURE PROTECTION Section 071800 Traffic Coatings Part 1 - General 1.01 Summary A. This specification describes the

More information

EPDM SINGLE-PLY SYSTEM SUMMARY

EPDM SINGLE-PLY SYSTEM SUMMARY EPDM SINGLE-PLY SYSTEM SUMMARY This is a generic summary of EDGE s more detailed EPDM SINGLE-PLY SYSTEM SPECIFICATION. For warranty purposes, Approved Applicators are responsible for studying, understanding,

More information

Henry #1 CHOICE OF PROFESSIONALS

Henry #1 CHOICE OF PROFESSIONALS Henry #1 CHOICE OF PROFESSIONALS GUIDE SPECIFICATION HENRY SPECIFICATION H1-PE-GN 1-PLY EXISTING ROOF SLOPE HENRY 107 Asphalt Em ulsion HENRY 107 Asphalt Em ulsion POLYESTER PLY SHEET GRANULES GUIDE SPEC

More information

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy SELECTION & SPECIFICATION DATA Generic Type Description Features Color Finish Primer Cycloaliphatic Amine Epoxy Highly chemical resistant epoxy mastic coating with exceptionally versatile uses in all industrial

More information

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER GRAVEL SURFACE BUR

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER GRAVEL SURFACE BUR SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER GRAVEL SURFACE BUR Part 1. 1.01 Description General Conditions A. Scope of Work Provide all materials, labor and equipment required for the installation

More information

Traffic Bearing Membrane

Traffic Bearing Membrane 7 07 18 11 Traffic Coatings Qualideck Traffic Bearing Membrane High-solids, 2-component polyurethane waterproofing, traffic bearing systems for vehicular and pedestrian areas PACKAGING Q152 Primer: 3 gal

More information

General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions.

General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions. General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions. Surface Preparation: Surface to be coated should be clean, dry and structurally sound.

More information

POLYMER CONCRETE 800 NON-SHRINK VINYL ESTER POLYMER CONCRETE, CONCENTRATED HYDROFLUORIC ACID RESISTANCE

POLYMER CONCRETE 800 NON-SHRINK VINYL ESTER POLYMER CONCRETE, CONCENTRATED HYDROFLUORIC ACID RESISTANCE RECOMMENDED APPLICATIONS Polymer Concrete 800 is a three-component, vinyl ester polymer concrete used for the construction of chemical resistant floors, pads, curbing, trenches and sumps. Polymer Concrete

More information

Magna Wall. Elastomeric Coatings (Non-Textured) Product Overview, Instructions, & Data

Magna Wall. Elastomeric Coatings (Non-Textured) Product Overview, Instructions, & Data Magna Wall Elastomeric Coatings (Non-Textured) Product Overview, Instructions, & Data s t u c c o D 9 Magna Wall Elastomeric Coatings (Non-Textured) product Overview Magna Wall Elastomeric Coatings are

More information

FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets

FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com FireShield

More information

CP-24CC Potassium Silicate Concrete

CP-24CC Potassium Silicate Concrete CP-24CC Potassium Silicate Concrete PRODUCT DESCRIPTION Blome CP-24CC is a two component, potassium silicate concrete used for acid resistant pump pads, equipment pads, curbing, floors and sumps. CP-24CC

More information

CHEMCURB SYSTEM. Penetration Seals

CHEMCURB SYSTEM. Penetration Seals Tomorrow's Solution for Today's Buildings U. S. Patent No. 5,493,827 U. S. Patent No. 5,768,838 CHEMCURB SYSTEM Penetration Seals DESCRIPTION: The CHEMCURB SYSTEM replaces old-style metal pitch pans with

More information

WPM WATERPROOFING MEMBRANE

WPM WATERPROOFING MEMBRANE WPM 300 - WATERPROOFING MEMBRANE Description WPM 300 Waterproofing Membrane is a single-pack, water based polyurethane modified synthetic rubber polymer, liquid membrane developed specifically as a tough,

More information

TECHNICAL DATA SHEET SIKABOND AT METAL GREY 300CC

TECHNICAL DATA SHEET SIKABOND AT METAL GREY 300CC TECHNICAL DATA SHEET SIKABOND AT METAL GREY 300CC SikaBond AT Metal is based on a new type of hybrid polymer. AT (Advanced Technology) is a combination of the powerful Sika polyurethane (PU) and modified

More information

Pol-E-Base Modified Bitumen Roof System

Pol-E-Base Modified Bitumen Roof System Pol-E-Base Modified Bitumen Roof System Specification Chemicals, Inc. produces the Pol-E-Base Built-up Roofing System as the ultimate in field applied reflective insulation roofing. It has the advantages

More information

Technical Bulletin 2400 Boston Street, Suite 200, Baltimore, Maryland Phone: or

Technical Bulletin 2400 Boston Street, Suite 200, Baltimore, Maryland Phone: or Technical Bulletin 2400 Boston Street, Suite 200, Baltimore, Maryland 21224 Phone: 410-675-2100 or 800-543-3840 Revised: 1/25/16 DAP 3.0 High Performance Concrete & Mortar Sealant Self-leveling, no tooling

More information

THE BRITE THING TO DO

THE BRITE THING TO DO REDUCING ENERGY CONSUMPTION IMPROVING AIR QUALITY THE BRITE THING TO DO BRITE-n-EZ Enhanced Coating Application Process on Black EPDM Roof Membrane BRITE-n-EZ EPDM Application Instructions CLEANING Remove

More information

TECHNICAL DATA SHEET HYDROPOX #2 4:1 EPOXY (MPI #115)

TECHNICAL DATA SHEET HYDROPOX #2 4:1 EPOXY (MPI #115) TECHNICAL DATA SHEET HYDROPOX #2 4:1 EPOXY (MPI #115) DESCRIPTION: A two component water base epoxy amine coating that provides excellent adhesion, solvent resistance and abrasion resistance with water

More information

Henry #1 CHOICE OF PROFESSIONALS

Henry #1 CHOICE OF PROFESSIONALS Henry #1 CHOICE OF PROFESSIONALS GUIDE SPECIFICATION HENRY SPECIFICATION H2-PE-GN 2-PLY EXISTING ROOF SLOPE HENRY 107 Asphalt Em ulsion HENRY 107 Asphalt Em ulsion POLYESTER PLY SHEET GRANULES GUIDE SPEC

More information

GUIDE SPECIFICATION SECTION 07576

GUIDE SPECIFICATION SECTION 07576 GUIDE SPECIFICATION SECTION 07576 TRAFFIC DECK MEMBRANE SYSTEM NOTE TO ARCHITECTS & ENGINEERS: The Oak Ridge traffic membrane system provides for applied high build, durable and waterproof membrane consisting

More information

Pacific Polymers Elasto-Mat D&G Guide Specification

Pacific Polymers Elasto-Mat D&G Guide Specification 1 07141-1 August 2016 Pacific Polymers Elasto-Mat D&G Guide Specification SECTION 07141 FLUID APPLIED WATERPROOFING 2 07141-2 August 2016 Pacific Polymers Elasto-Mat D&G Guide Specification SECTION 07141

More information

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification Product Data Sheet Pondseal Waterproofing Membrane for Ponds and Water Features Description Pondseal is a polyurethane / acrylic co-polymer, water based coating which when fully cured, forms an impervious,

More information

T E C H N I C A L D A T A S H E E T

T E C H N I C A L D A T A S H E E T DESCRIPTION ADSEAL DWS 4580 SERIES is a one-component sealant/adhesive that vulcanizes to a durable elastic rubber silicone in contact with ambient humidity. Due to its rheological and non-sagging characteristics,

More information

TL-250AR Abrasion Resistant, Glass Flake Filled, Vinyl Ester Tank Lining System

TL-250AR Abrasion Resistant, Glass Flake Filled, Vinyl Ester Tank Lining System TL-250AR Abrasion Resistant, Glass Flake Filled, Vinyl Ester Tank Lining System PRODUCT DESCRIPTION TL-250AR is a Vinyl Ester Tank Lining system based on a glass flake filled, trowel-on base coat and a

More information

Distributed by: BEST MATERIALS Ph: , Fax:

Distributed by: BEST MATERIALS Ph: , Fax: ChemCurbs can eliminate the number one cause of roof leaks. Properly Installed ChemCurb Penetration Seals fillers shrink and then leak, allowing water to penetrate and enter the building. These pitchpans

More information

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric Sealant

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric Sealant Spec Component: SC-071NSEZ-03/10 Sikaflex-2c NS EZ Part 1 - General DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section 07900 Joint Sealers Elastomeric and non-elastomeric Sealant 1.01 Summary A. This

More information

Dist. by: BEST MATERIALS Ph:

Dist. by: BEST MATERIALS Ph: Commercial Moisture Cure Sealants 8500 Silicone Sealant High-Solids Neutral Cure Oxime Silicone Sealant. Ideal for exterior joints, metal roofing, windows and doors. Clear and White. 1 gal. pails* 3.5

More information

Commercial Moisture Cure Sealants

Commercial Moisture Cure Sealants Commercial Moisture Cure Sealants 8500 Silicone Sealant High-Solids Neutral Cure Oxime Silicone Sealant. Ideal for exterior joints, metal roofing, windows and doors. Clear and White. 1 gal. pails* 3.5

More information

TECHNICAL DATA SHEET HYDROPOX #4 QD 1:1 EPOXY WATERWHITE CLEAR

TECHNICAL DATA SHEET HYDROPOX #4 QD 1:1 EPOXY WATERWHITE CLEAR TECHNICAL DATA SHEET HYDROPOX #4 QD 1:1 EPOXY WATERWHITE CLEAR DESCRIPTION: A two component water base epoxy amine coating that provides excellent adhesion, solvent resistance and abrasion resistance with

More information

SECTION SELF-ADHERING SHEET WATERPROOFING

SECTION SELF-ADHERING SHEET WATERPROOFING SECTION 07 13 26 SELF-ADHERING SHEET WATERPROOFING This guide specification has been prepared by Polyguard Products Inc., in printed and electronic media, as an aid to specifiers in preparing written construction

More information

3 500-Series Polyurethane Products:

3 500-Series Polyurethane Products: 3 500-Series Polyurethane Products: 3M Polyurethane Construction Sealant 525 3M Polyurethane Construction Sealant 535 3M Polyurethane Sealant 540 3M Polyurethane Adhesive Sealant Fast Cure 550 3M Polyurethane

More information

The Cool Roofing Solution

The Cool Roofing Solution The Cool Roofing Solution & Product Guide BEFORE AFTER The Cool Roofing Solution Before After What is a cool roof? A cool roof is one that reflects and releases the sun s energy away from the building

More information

Refer to Substrates & Surface Preparation.

Refer to Substrates & Surface Preparation. SELECTION & SPECIFICATION DATA Generic Type Description Features Aliphatic Acrylic Polyurethane High gloss finish with exceptional weathering performance characteristics. Used extensively in virtually

More information

MEMBRANE 510/510R Low VOC Flexibilized, Urethane Membrane mils

MEMBRANE 510/510R Low VOC Flexibilized, Urethane Membrane mils GREEN BUILDING FEATURES Contributes towards satisfying Credit 4.2 under LEED Contains recycled post industrial crushed glass Contains rapidly renewable materials Meets California South Coast Air Quality

More information

Technical Bulletin 2400 Boston Street, Suite 200, Baltimore, Maryland Phone: or

Technical Bulletin 2400 Boston Street, Suite 200, Baltimore, Maryland Phone: or Technical Bulletin 2400 Boston Street, Suite 200, Baltimore, Maryland 21224 Phone: 410-675-2100 or 800-543-3840 Revised: 1/25/16 DAP 3.0 High Performance Kitchen, Bath & Plumbing Sealant Gloss White &

More information

TOPCOAT Restoration Specifications Structural Concrete

TOPCOAT Restoration Specifications Structural Concrete TOPCOAT Restoration Specifications Structural Concrete Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com TOPCOAT Restoration Specifications Structural Concrete

More information

Liquid Membrane Systems Product Guide

Liquid Membrane Systems Product Guide Liquid Membrane Systems Product Guide About Armour Proof Coatings Primers, Sealers / Mastics Armour Proof Coatings uses over 3 decades of technology and 5 decades of roofing expertise to provide a solution

More information

Pacific Polymers Elasto-Deck BT Guide Specification

Pacific Polymers Elasto-Deck BT Guide Specification 1 07141-1 August 2016 Pacific Polymers Elasto-Deck BT Guide Specification SECTION 07141 FLUID APPLIED WATERPROOFING 2 07141-2 August 2016 Pacific Polymers Elasto-Deck BT Guide Specification SECTION 07141

More information

DOWSIL ALLGUARD Silicone Elastomeric Coating

DOWSIL ALLGUARD Silicone Elastomeric Coating Technical Data Sheet Water-based silicone elastomer for waterproofing above-grade exterior masonry substrates Features & Benefits Provides long-term waterproofing protection Maintains water protection

More information

Henry #1 CHOICE OF PROFESSIONALS

Henry #1 CHOICE OF PROFESSIONALS Henry #1 CHOICE OF PROFESSIONALS GUIDE SPECIFICATION HENRY SPECIFICATION H1-PC-GN 1-PLY EXISTING ROOF SLOPE HENRY 902 Perm anent Bond or 903 High Solids Adhesive HENRY 902 Perm anent Bond or 903 High Solids

More information

A. This Section includes traffic coatings for the following applications:

A. This Section includes traffic coatings for the following applications: SECTION 071800 - TRAFFIC COATINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes traffic coatings for the following applications: 1. Interior and exterior, pedestrian traffic. 2. Vehicular traffic.

More information