Radon and the Alberta Building Code 2014

Size: px
Start display at page:

Download "Radon and the Alberta Building Code 2014"

Transcription

1 Radon and the Alberta Building Code 2014 Presented by: Karin Dumais, B.Sc. President, Radon West Ltd. Director, Canadian National Radon Training Centre Ph RADON OK ( )

2 If Levels Are Still High After Occupancy It is fixable Basic system - ~cost under $ Mitigations are effective Our avg. post mit. #s are 42 Bq/m³

3 Today s Agenda Quick introduction to radon Breaking radon myths Implementing ABC 2014 in the field Things to think about

4 Looks Safe But It Wasn t

5 What is radon? - Radioactive gas - Comes from the soil - Can t see it, taste it or smell it

6 Bq/m³ (Becquerel per meter cubed) The unit of measure used in Canada = 1 radioactive decay / second /meter³

7 Why do we care about radon? 16% of all lung cancers are radon induced in Canada Ionizing radiation

8

9 Breaking Myths

10 MYTH: The health risk is a Healthy DNA long term exposure Radiation damage Broken DNA replicates DNA damage is immediate Diagnosis is later DNA may heal itself wrong Broken Replicates Broken DNA over and over This is how cancer starts

11 MYTH: We don t have radon here

12 Home in the Calgary Area ,194 dental X-rays per year If you worked in a nuclear plant for 5 years at this level of radiation you would only have been allowed to be there 4 months of each year due to maximum dosage levels being reached for OHS reasons Home in Calgary Area Health Canada Action Level USA EPA Action Level WHO Action Level Avg. Indoor Levels Avg.Outdoor Levels Bq/m

13 MYTH: I can test for radon before I build my house

14 MYTH: My house is old so I won t have high levels My house is new so I won t have high levels Source: Dwight Burdette

15 Unless you live in one of these

16 Or one of these

17 MYTH: My neighbour had low levels so I won t test high Low Radon? High Radon?

18 MYTH: Houses have one radon level

19 MYTH: You can seal radon out of It is just too small - radon is a single atom 1 million radon atoms side by side equals the width of a single strand of human hair a building

20 MYTH: Radon is only a basement issue

21 MYTH: Radon in the home is natural House tests at 654 Bq/m³ 10 Bq/m³ outdoor avg. Source E. Walker

22 MYTH: Radon fans need to be outside and the piping vented above the eavestrough TOO COLD!

23

24 What is the end goal of the building code changes? Easier and more effective retro-fits for active radon mitigation systems if required in the future

25 Differences from Existing Code Part 9 Soil Gas Control 2006 ABC 2014 ABC (prescriptive) - Clean gravel (opt) - Clean gravel - Poly under slab - Perimeter sealed - Penetrations sealed - Radon pipe under slab - Labelled and capped - Sump pit airtight Note: There are also allowances for some performance measures

26 Also Includes Appendix Notes and Illustrations

27 Requirements for ground cover

28 -Min. 100 mm of granular fill under slab - Less than 10% of material through a 4 mm sieve

29

30 There are performance options

31 Air barrier required under slab Source: cottonwood passivehouse.ca

32 Foundation Sealed to the Foundation - Extended Vapour Barrier Footing Slab Pros: - Easy visual inspection that air barrier and seal are there Cons: - Time and time = $ - Risk of barrier being compromised and radon finding paths into the building

33 Poly compromised within 48 hours

34 Expect to see sealing on footing instead of at foundation wall

35 Foundation Sealed to the Footing Footing Slab Pros: - Fast - that means < $ Cons: - No visual inspection that air barrier and seal are there - Critical to have a good perimeter seal at slab and foundation joint once the slab is poured

36 Foundation Sealed to the Foundation Cut Vapour Barrier at Slab Pros: Elastomeric polyurethane seals together foundation, slab and air barrier Footing Slab Cons: - Time and time = $ - Can only see air barrier before perimeter seal is completed

37 Slab to wall joint caulked (5)

38 Prepare the joint

39 Elastomeric Polyurethane Choose materials that are fit for purpose e.g. green concrete

40 Not enough caulk

41 Should use about one 300 ml tube of elastomeric polyurethane caulk approx. every 7 feet

42 Flattening and pushing against the walls to force caulk against surfaces

43 All penetrations (i.e. pipes, utilities) sealed

44

45 Radon collection systems - Not Good!

46 Pipe Inlet/outlet

47 Various acceptable - Prescriptive inlet and outlet configurations

48 Straight and braced

49 Loops of perforated pipe increase air flow and reduce pipe blockage

50 Loop of perforated 4 weeping tile

51 Perforated pipe off a T in a loop with Schedule 40 4 pipe

52 Sump lids can also be the inlet and outlet (Performance) Very effective mitigation systems No additional holes space savers Already need sealed sump lids add some perforated pipe from the pit to the centre of building Some models allow for sump maintenance without disturbing the installed radon mitigation system

53

54

55 Outlet is capped airtight and labeled

56 Not good. Temporary caps and not airtight

57 Not a sewer line it has happened.

58 Sump pit cover required to be airtight

59 Not good. Not sealed around pipe Large horseshoe opening

60 Prescriptive (Deemed to Comply) Perimeter sealing at slab and foundation

61

62 Task Completed - % Compliant Accessible Capped Labelled Sump Perimeter Sealed

63 Things we have seen Source: Hash Milhan

64 Cap them!

65 VENT TERMINAL CLEARANCES CSA-B149.1 Natural Gas and Propane Installation Code

66 Rough-in outlet not in a useable location Likely to be abandoned if future active mitigation system required

67 Furnace placed too close to radon rough-in Rough in Furnace

68 Hung furnace

69 --- Large opening to sub-slab left under furnace

70 Place Radon Pipe Through Interior Strip Footings

71 If Levels Are Still High After Occupancy It is fixable Basic system - ~cost under $ Mitigations are effective Our avg. post mit. #s are 42 Bq/m³

72 Thank you and wishing you all low levels of radon in your homes and workplaces. Karin Dumais Ph.403. RADON OK ( )

Radon Demonstration: Application of Building Code Changes in Winnipeg New Home Construction. April 2014

Radon Demonstration: Application of Building Code Changes in Winnipeg New Home Construction. April 2014 Radon Demonstration: Application of Building Code Changes in Winnipeg New Home Construction April 2014 Contents Summary... 2 Background... 3 Project Details... 4 The Stakeholders... 4 Parameters... 4 Findings...

More information

RADON ABATEMENT FROM THE GROUND UP

RADON ABATEMENT FROM THE GROUND UP RADON ABATEMENT FROM THE GROUND UP The solution for a dry, comfortable, and durable basement! CLOSED-CELL 2018 Demilec, 3315 E. Division St., Arlington, TX 76011 Phone: 817.640.4900 Fax: 817.633.2000 Info@Demilec.com

More information

Annex A STATEMENT OF WORK Radon Mitigation

Annex A STATEMENT OF WORK Radon Mitigation Annex A STATEMENT OF WORK Radon Mitigation OBJECTIVE Royal Canadian Mounted Police (RCMP) requires reduction of the annual radon concentration levels within the noted 15 properties (found on Appendix B)

More information

Radon Resistant New Construction. Topic 8 - Audio 64

Radon Resistant New Construction. Topic 8 - Audio 64 Topic 8 - Audio 64 EPA Map of Radon Zones Designations drawn in by county boundary to match code jurisdictions Indicates the potential for a short-term measurement in the lowest portion of the home to

More information

Chapter 2: Foundation

Chapter 2: Foundation Chapter 2: Foundation Crawlspace [V502.1.2] [V502.1.2] [V502.1.3] Vents. Vents in the crawlspace help keep floor insulation and floor framing dry. Crawlspace vents also reduce the potential for radon buildup

More information

Radon Control Methods for Existing and New Residential Structures

Radon Control Methods for Existing and New Residential Structures Delivered at the October 2006 Meeting of the Colorado Chapter of the International Code Council Presented by: Douglas L. Kladder Center for Environmental Research & Technology, Inc. Through a grant from

More information

Managing Radon PRESENTATION BY: KEITH, ROB, LISA, & WILLEM

Managing Radon PRESENTATION BY: KEITH, ROB, LISA, & WILLEM Managing Radon PRESENTATION BY: KEITH, ROB, LISA, & WILLEM MARCH 2018 INTRODUCTIONS BY WILLEM The focus for our presentation is requesting support for improvements to Building Code performance requirements

More information

Radon Vent Pipe System. Labeling Performance Indicators

Radon Vent Pipe System. Labeling Performance Indicators Section 6 Radon Vent Pipe Labeling Performance Indicators Radon Vent Pipe System Connected after sub-grade system installed Pipe cannot be trapped Provide space in chases Support at each floor level Discharge

More information

Paul V. Jennemann MARYLAND RADON LABORATORY, INC E Corporate Court Ellicott City, MD

Paul V. Jennemann MARYLAND RADON LABORATORY, INC E Corporate Court Ellicott City, MD Radon Mitigation Standards, 2000 International Residential Code vs. EPA Mitigation Standards Paul V. Jennemann MARYLAND RADON LABORATORY, INC. 3220-E Corporate Court Ellicott City, MD 2 1042 ABSTRACT This

More information

City of Grand Island Tuesday, March 25, 2014 Council Session (Corrected)

City of Grand Island Tuesday, March 25, 2014 Council Session (Corrected) City of Grand Island Tuesday, March 25, 2014 Council Session (Corrected) Item F-4 #9481 - Consideration of Amending Chapter 8-14 of the Grand Island City Code Relative to Buildings Staff Contact: Craig

More information

CONSEQUENCES OF INCORRECT DESIGN AND UNQUALIFIED REALIZATION ON RELIABILITY AND EFFECTIVENESS OF RADON REDUCTION MEASURES

CONSEQUENCES OF INCORRECT DESIGN AND UNQUALIFIED REALIZATION ON RELIABILITY AND EFFECTIVENESS OF RADON REDUCTION MEASURES CONSEQUENCES OF INCORRECT DESIGN AND UNQUALIFIED REALIZATION ON RELIABILITY AND EFFECTIVENESS OF RADON REDUCTION MEASURES Martin Jiránek, Czech Technical University, Faculty of Civil Engineering, Praha

More information

INSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST

INSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST Village of Vernon Hills Community Development Department - Building Division 290 Evergreen Drive, Vernon Hills, IL 60061 Phone 847-367-3704 - Fax 847-367-2541 - http://www.vernonhills.org INSPECTION TIMING

More information

APPENDIX C. Chapter 9B-53 STANDARD FOR MITIGATION OF RADON IN EXISTING BUILDINGS

APPENDIX C. Chapter 9B-53 STANDARD FOR MITIGATION OF RADON IN EXISTING BUILDINGS Chapter 9B-53 STANDARD FOR MITIGATION OF RADON IN EXISTING BUILDINGS 9B-53.001 9B-53.002 9B -5 3.003 9B-53.004 Purpose and Intent. (Repealed) Definitions. Department Activities. Florida Standard for Mitigation

More information

What We Have Learned From Retrofit Studies. Stacy Gloss, research specialist Indoor Climate Research and Training University of Illinois

What We Have Learned From Retrofit Studies. Stacy Gloss, research specialist Indoor Climate Research and Training University of Illinois What We Have Learned From Retrofit Studies Stacy Gloss, research specialist Indoor Climate Research and Training University of Illinois 1 2 Identify radon zones on EPAs radon zone map. Describe differences

More information

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION Town of Hague Building Inspector: Dale Wagner Home #: 306-225-2265 Cell #: 306-241-4741 Fill all part of the permit application including the date and signature.

More information

VILLAGE OF DOWNERS GROVE REPORT FOR THE VILLAGE COUNCIL MEETING APRIL 1, 2014 AGENDA

VILLAGE OF DOWNERS GROVE REPORT FOR THE VILLAGE COUNCIL MEETING APRIL 1, 2014 AGENDA VILLAGE OF DOWNERS GROVE REPORT FOR THE VILLAGE COUNCIL MEETING APRIL 1, 2014 AGENDA ITEM ORD 00-05506 SUBJECT: TYPE: SUBMITTED BY: Adoption of Radon Mitigation Standards for New Residential Construction

More information

Inspection of New One- and Two- Family Dwellings

Inspection of New One- and Two- Family Dwellings Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Inspection of New One- and Two- Family Dwellings Planning and Development

More information

TABLE OF CONTENTS

TABLE OF CONTENTS DIVISION 33: SEWER AND SEPTIC SYSTEMS 33 3633 UTILITY SEPTIC TANK DRAINAGE FIELD TABLE OF CONTENTS 33 0000-1 SECTION 33 3633-- UTILITY SEPTIC TANK DRAINAGE FIELD PART 1 - GENERAL 1.1 SUMMARY A. Includes

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS The following instructions are provided for the installation of Radon Guard rigid board sub-slab insulation and radon gas mitigation. Radon Guard should be installed by a professional

More information

Section 10 Design Criteria: Components

Section 10 Design Criteria: Components 1. Tanks and Vaults Section 10 Design Criteria: Components a. Watertightness i. Septic tanks, vaults, dosing tanks, other treatment components, risers and lids must not allow infiltration of ground water

More information

Attic Access Hatch to have an area not less than 0.32m²/3.4ft² and no dimension less than 500mm with a min R-15 insulation value Crawlspace

Attic Access Hatch to have an area not less than 0.32m²/3.4ft² and no dimension less than 500mm with a min R-15 insulation value Crawlspace NOTABLE CODE REQUIREMENTS the following list represents important code requirements that shall be implemented into construction while still maintaining full compliance with all other requirements within

More information

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012 2012 Ontario Building Code Requirements for New Construction Bradford West Gwillimbury Building Division March 5, 2012 1 Ontario Building Code changes Applicable to permits applied for after December 31,

More information

Supplementary Standard SB-12. Energy Efficiency For Housing

Supplementary Standard SB-12. Energy Efficiency For Housing OBC Excerpt: SB 12 Ministry of Municipal Affairs and Housing Building and Development Branch 2006 Building Code - Supplementary Standards Supplementary Standard SB-12 Energy Efficiency For Housing November

More information

Foundations. Issue. Slab-On-Grade Liquid Water Control (See Figure 2-2) Goals. Guidance

Foundations. Issue. Slab-On-Grade Liquid Water Control (See Figure 2-2) Goals. Guidance www.epa.gov/iaq/moisture Foundations Issue Building foundations are vulnerable to moisture problems for a number of reasons, including: Water from rain and from plumbing leaks is drawn by gravity to foundations,

More information

Homeowner s Guide Foundation Water PenetrationTips TIPS TO IDENTIFY WATER PENETRATION PROBLEMS / CRACKING BASEMENTS

Homeowner s Guide Foundation Water PenetrationTips TIPS TO IDENTIFY WATER PENETRATION PROBLEMS / CRACKING BASEMENTS Homeowner s Guide Foundation Water PenetrationTips TIPS TO IDENTIFY WATER PENETRATION PROBLEMS / CRACKING BASEMENTS MAINTAINING YOUR HOME BASEMENT FOUNDATION BY HOMEOWNER PREVENTATIVE MAINTENANCE LUX WATERPROOF

More information

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested.

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested. Purpose 355 West Queens Road Single Family New Construction Required Inspection Stages Master Requirement GEN 110 Building Department: 604-990-2480, building@dnv.org, fax: 604-984-9683 The following procedure

More information

Florida Energy Extension Service

Florida Energy Extension Service Florida Energy Extension Service Radon: The Gas, Threat, Detection, and Control 1 Gary D. Cook 2 THE GAS Radon is a potentially dangerous radioactive gas occurring naturally in the environment. It is one

More information

Testing Is Easy And Inexpensive

Testing Is Easy And Inexpensive Doug Kladder Center for Environmental Research and Technology, Inc. Testing Is Easy And Inexpensive Short And Long-Term Testing Devices Help Determine the Need for, and Effectiveness of, Radon Mitigation

More information

Request for Proposal

Request for Proposal 12 E 4 th St, Duluth MN 55805 July 17, 2018 Request for Proposal BID #: Grand Marais Phase 2 2018 PROJECT NAME: Nordic Star Housing Development Phase 2 ANNOUNCEMENT DATE: July 17, 2018 DUE DATE: July 24,

More information

RADON REDUCTION GUIDE FOR CANADIANS

RADON REDUCTION GUIDE FOR CANADIANS RADON REDUCTION GUIDE FOR CANADIANS RADON RADON Health Canada is the federal department responsible for helping the people of Canada maintain and improve their health. We assess the safety of drugs and

More information

FirstEnergy Program Overview

FirstEnergy Program Overview FirstEnergy Program Overview Builder incentives $400 per unit + $0.10/kWh in projected savings Eligibility Located in service area of a FirstEnergy Utility Certificate of Occupancy Dates: FirstEnergy Ohio

More information

Estimated Cost Ranges for Completing Residential Flood Protection Projects

Estimated Cost Ranges for Completing Residential Flood Protection Projects Estimated Ranges for Completing Residential Flood Protection Projects Introduction to the Home Flood Protection Program The Home Flood Protection Program is an educational service designed to help homeowners

More information

Introduction. Installation

Introduction. Installation ADVANCE CONCRETE & PRE-CAST HOLDING PTY LTD A.C.N.083 235 536 50 Victoria street Riverstone N.S.W. P.O Box130 Riverstone n.s.w. 2765 Phone 02 96276476 fax 02 96276478 Introduction To supply Grease Traps

More information

2014 British Columbia Building Code Changes

2014 British Columbia Building Code Changes 2014 British Columbia Building Code Changes A City of Prince George interpretation of the 2014 Building Code Changes for 9.32 & 9.36 The following changes reflect the most notable revisions and staff interpretations.

More information

9.36 Energy Efficiency

9.36 Energy Efficiency 9.36 Energy Efficiency Housing 1 Credits and Source Material National Research Council of Canada Manitoba Office of the Fire Commissioner City of Brandon Planning & Building Safety Department Canadian

More information

2010 National Building Code Adoption and Associated Process Changes

2010 National Building Code Adoption and Associated Process Changes Building Inspection City of Moncton 655 Main Street Moncton, NB E1C 1E8 Phone: (506) 856-4375 Fax: (506) 856-4348 Bulletin No. 14 From: Randy Richard Date: February 9, 2015 Subject: 2010 National Building

More information

NEWS LETTER. May 9, 2011

NEWS LETTER. May 9, 2011 PLANNING, BUILDING & DEVELOPMENT SERVICES DEPARTMENT 580-1 Street S.E. Medicine Hat, Alberta T1A 8E6 Telephone: 529-8374 FAX 502-8038 NEWS LETTER May 9, 2011 GENERAL As per requests from the construction

More information

Complete and simple system!

Complete and simple system! System Platon RadonStop 400 Complete and simple system! Platon RadonStop 400 is a non-reinforced polyethylene film with high strength and flexibility. The film is supplied in 4m widths and is installed

More information

2/23/2009 R15-R20R20

2/23/2009 R15-R20R20 Foundations What is important to know about foundations? You (probably) won t design it What are the components that make up a properly designed and built foundation? Determine whether house has a good

More information

SUB-SLAB DIAGNOSTICS

SUB-SLAB DIAGNOSTICS SUB-SLAB DIAGNOSTICS John W. Anderson, Jr. Quality conservation Spokane, WA ABSTRACT Sub-slab diagnostics have eluded most radon contractors because 90% of installed systems work OK. the contractors are

More information

radon A Guide for Canadian Homeowners Health Canada Santé Canada

radon A Guide for Canadian Homeowners Health Canada Santé Canada radon A Guide for Canadian Homeowners Health Canada Santé Canada CMHC Home to Canadians Canada Mortgage and Housing Corporation (CMHC) has been Canada s national housing agency for more than 60 years.

More information

Encapsulated, Sealed & Closed Crawlspace Installation Manual

Encapsulated, Sealed & Closed Crawlspace Installation Manual YourCrawlSpace, Inc. 1007 Johnni4 Dodds Blvd. Mt. Pleasant, SC 29464 Toll Free: 877-44-CRAWL (27295) Local: (843) 593-1115 Encapsulated, Sealed & Closed Crawlspace Installation Manual Copyright 2017 Your

More information

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection EFFECTIVE FEBRUARY 2014 note: drainage permit required to call for a dampproof inspection PERMITS & INSPECTIONS 750 17th Street West Vancouver BC V7V 3T3 westvancouver.ca/permits t: 604-925-7040 f: 604-925-7234

More information

female pipe. A Wall Support must be installed just above the tee and at least every 8 feet thereafter. If the pipe is to be run through a roof overhang then a Flashing, Storm Collar and Vertical Rain Cap

More information

Evergreen Project Implementation Plan Instructions Low Income Housing Tax Credit Program

Evergreen Project Implementation Plan Instructions Low Income Housing Tax Credit Program Evergreen Project Implementation Plan Instructions Low Income Housing Tax Credit Program The following table provides a brief description of the documentation that will be required of successful LIHTC

More information

Pilot Project on Radon Gas

Pilot Project on Radon Gas PROJECT REPORT: PILOT PROJECT ON RADON GAS OCTOBER 2018 PROJECT REPORT: Pilot Project on Radon Gas Background The Co-operative Housing Federation of Canada and the Agency for Co-operative Housing recently

More information

Testing Is Easy And Inexpensive

Testing Is Easy And Inexpensive Radon Resistant New Construction Doug Kladder Center for Environmental Research and Technology, Inc. November 2012 Testing Is Easy And Inexpensive Page 1 Short And Long-Term Testing Devices Help Determine

More information

The Inspection Process. Waxhaw N.C.

The Inspection Process. Waxhaw N.C. The Inspection Process In Waxhaw N.C. This information is provided by the Waxhaw Enforcement Division to assist you in the progression of your project. Nothing in this document should be considered "Code"

More information

Building Envelope Solutions, Inc. Identifying solutions for better building performance

Building Envelope Solutions, Inc. Identifying solutions for better building performance Building Envelope Solutions, Inc. Identifying solutions for better building performance The BES/FOAM-TECH AVID System (Air/Vapor/Insulation/Drainage) The AVID System was developed by Building Envelope

More information

Installation Guidelines VBC Products

Installation Guidelines VBC Products Installation Guidelines VBC Products Composite STEP 1A: Ground Surface Preparation Earth Base Select the suitable product (VBC-350, 31 mil) and ensure the installation surface is relatively smooth. Barrier-Bac

More information

SEWER BACKUP. The facts about. A guide to protecting what matters most. For more information, talk to your broker or insurance adjuster.

SEWER BACKUP. The facts about. A guide to protecting what matters most. For more information, talk to your broker or insurance adjuster. The facts about For more information, talk to your broker or insurance adjuster. Economical Insurance includes the following companies: Economical Mutual Insurance Company, The Missisquoi Insurance Company,

More information

Notes. Lesson overview. This lesson discusses how radon enters a home, where people can be exposed to unhealthy levels.

Notes. Lesson overview. This lesson discusses how radon enters a home, where people can be exposed to unhealthy levels. Lesson 3: How does radon enter a home? Lesson overview This lesson discusses how radon enters a home, where people can be exposed to unhealthy levels. Lesson objectives By the end of this lesson, the learners

More information

NORTH CAROLINA ENERGY STAR CONFERENCE

NORTH CAROLINA ENERGY STAR CONFERENCE NORTH CAROLINA ENERGY STAR CONFERENCE NOVEMBER 16, 2007 ENERGY STAR INDOOR AIR PACKAGE OUTLINE What s so important about IAQ? What is the Indoor Air Package? How does it work? WHAT ARE BUILDINGS FOR? People

More information

Radon in civil engineering building code, building standards, guidelines for building professionals

Radon in civil engineering building code, building standards, guidelines for building professionals Radon in civil engineering building code, building standards, guidelines for building professionals STUK - Radiation and nuclear safety authority Finland IAEA Regional Workshop, Sofia, Bulgaria Oct 16,

More information

An Introduction to Radon

An Introduction to Radon An Introduction to Radon Kristian James MPH CEnvH Principal Environmental Public Health Specialist Public Health Wales Specialist content provided by the Radon Group - Programmes Team, PHE Centre for Radiation,

More information

Section 02 SUBSTRUCTURE

Section 02 SUBSTRUCTURE 02 Section 02 SUBSTRUCTURE 1. Trenches to be level, square and free from loose material and standing water. Steps and sides of foundations must be plumb. 2. All tree roots must be removed. Trench depths

More information

Finding the Balance Defining the Responsibilities of Utility, Insurance, Disaster Recovery Agencies and Property Owners to Address Flooding Challenges

Finding the Balance Defining the Responsibilities of Utility, Insurance, Disaster Recovery Agencies and Property Owners to Address Flooding Challenges Attachment 1 Finding the Balance Defining the Responsibilities of Utility, Insurance, Disaster Recovery Agencies and Property Owners to Address Flooding Challenges Recommendation: Utility Committee receives

More information

Canadian Supplement to CERTI Radon Mitigation Course

Canadian Supplement to CERTI Radon Mitigation Course Canadian Supplement to CERTI Radon Mitigation Course Everything you have learned PLUS! Assumes you have viewed the Canadian Measurement Course Supplement 2013 Center for Environmental Research and Technology,

More information

High River, Okotoks & MD of Foothills Builders Forum Highlights to Part 9 of the Alberta Building Code 2014

High River, Okotoks & MD of Foothills Builders Forum Highlights to Part 9 of the Alberta Building Code 2014 High River, Okotoks & MD of Foothills Builders Forum Highlights to Part 9 of the Alberta Building Code 2014 Highlights of the Alberta Building Code 2014 Introduction Presentation topics Geoff Brownlie,

More information

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu INSTALLATION INSTRUCTIONS Note: The following installation instructions are based off of ASTM E 1643 (Standard Practice for Installation of Water Vapor Retarders Used in Contact with Earth or Granular

More information

RADON WELLISUMP BASIN FOR NEW HOME CONSTRUCTION

RADON WELLISUMP BASIN FOR NEW HOME CONSTRUCTION RADON WELLISUMP BASIN FOR NEW HOME CONSTRUCTION Paul V. Jennemann Maryland Radon Laboratory, Inc. Ellicott City, MD ABSTRACT This paper will describe a radon-well/sump-basin (patent applied for) for installation

More information

Andy Schreder CBO Building Official for St Francis, Nowthen

Andy Schreder CBO Building Official for St Francis, Nowthen Andy Schreder CBO Building Official for St Francis, Nowthen Voluntary Compliance Webster says: Voluntary means from one s own choice or consent. Of their own free will Compliance is conformity in fulfilling

More information

Request for Proposal

Request for Proposal March 23, 2018 Request for Proposal BID #: Lutsen #1 2018 PROJECT NAME: Lutsen Apartments, Lutsen, MN ANNOUNCEMENT DATE: March 23, 2018 DUE DATE: April 6, 2018 at Noon PUBLIC BID OPENING: April 6, 2018

More information

RESIDENTIAL FIRE SERVICE METERS Addendum #1

RESIDENTIAL FIRE SERVICE METERS Addendum #1 109 WATER METERS (Addendum #1) 109.1 GENERAL All meters to be used for billing purposes shall be provided by the Water Utility. The Water Utility reserves the right to read, inspect, test or replace the

More information

Building and Inspection Services Building Codes

Building and Inspection Services Building Codes Building and Inspection Services Building Codes Scott Ford, Manager Building Safety Codes October 2015 Presentation Team - Wayne Olsen, Safety Codes Officer, Field Supervisor - Annie Arsenault, Safety

More information

PLUMBING BUILDING SCOPE OF WORK

PLUMBING BUILDING SCOPE OF WORK PLUMBING BUILDING SCOPE OF WORK 1. The Contractor shall furnish all supervision, materials, labor, equipment, tools, supplies, incidental items, including construction cleanup, etc for accomplishing the

More information

Radon Mitigation Technology

Radon Mitigation Technology Radon Mitigation Technology Field Exercise Package Includes: Description of Mentoring Program Mentor Selection Criteria Field Exercises Field Exercise Verification Form Course Evaluation This field exercise

More information

Gas Protection System Components

Gas Protection System Components Page 1 Visqueen Gas Protection Visqueen Building Products is recognised as the leader in the development, production and supply of high quality construction related ground gas protection membranes. The

More information

Welcome to this continuing education seminar. This is the first of three parts of the Building Enclosure Fundamentals series.

Welcome to this continuing education seminar. This is the first of three parts of the Building Enclosure Fundamentals series. Welcome to this continuing education seminar. This is the first of three parts of the Building Enclosure Fundamentals series. 1 3 6 7 8 The primary reasons to build airtight buildings are to avoid drafts

More information

Healthier Home Environments Benefit Everyone

Healthier Home Environments Benefit Everyone Healthier Home Environments Benefit Everyone ALA Health House Mission To improve the way homes are built, renovated and maintained in America to be: Healthier More energy efficient More resource efficient

More information

Distribution Restriction Statement

Distribution Restriction Statement DEPARTMENT OF THE ARMY U.S. Army Corps of Engineers CEMP-ET Washington, DC 20314-1000 ETL 1110-3-438 Technical Letter No. 1110-3-438 15 September 1993 Engineering and Design INDOOR RADON PREVENTION AND

More information

Radon & Methane Gas IMPORTANT

Radon & Methane Gas IMPORTANT Radon & Methane Gas Radon Gas is everywhere - it is the extent that varies and structures are required to be built so radon exposure risk is minimised. IMPORTANT Every building must be designed and constructed

More information

FIELD COPY ATTACHMENT

FIELD COPY ATTACHMENT FIELD COPY ATTACHMENT The released plans for the project must be on site and available to the inspectors at all times. No inspection will be done without the released field plans. If you have any questions,

More information

Building codes and corrective actions

Building codes and corrective actions WORKSHOP ON THE CONTROL OF PUBLIC EXPOSURE IN COMPLIANCE WITH THE INTERNATIONAL BASIC SAFETY STANDARDS Cape town 5-7 May 2016 Building codes and corrective actions Martin Jiránek CZECH TECHNICAL UNIVERSITY,

More information

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs November 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements....................................

More information

CITY OF GAINESVILLE DEPARTMENT OF WATER RESOURCES

CITY OF GAINESVILLE DEPARTMENT OF WATER RESOURCES CITY OF GAINESVILLE DEPARTMENT OF WATER RESOURCES BACKFLOW PREVENTION PROGRAM SPECIFICATIONS AND DETAILS FOR INSTALLATION OF BACKFLOW ASSEMBLIES TABLE OF CONTENTS Introduction I General Information 1 Category

More information

Below Grade Moisture Management Drain Field-Drain Tile Installation

Below Grade Moisture Management Drain Field-Drain Tile Installation Below Grade Moisture Management Drain Field-Drain Tile Installation 1 So, you thought our Sump Basket ideas and instructions were worth sump-thing? (Well, you ended up here at least!) If you installed

More information

Commonwealth of Massachusetts City/Town of Septic System Installation Checklist

Commonwealth of Massachusetts City/Town of Septic System Installation Checklist Important: When filling out forms on the computer, use only the tab key to move your cursor - do not use the return key. DEP has provided this form for use by local Boards of Health if they wish to do

More information

BRINGING RADON BACK ON THE RADAR

BRINGING RADON BACK ON THE RADAR BY GORD COOKE BRINGING RADON BACK ON THE RADAR In the indoor air quality (IAQ) business the current pressing concern seems to be mould. Mould and moisture issues dominate articles in industry journals

More information

2010 NATIONAL BUILDING CODE

2010 NATIONAL BUILDING CODE 2010 NATIONAL BUILDING CODE 2010 NBC The 2010 Building and Fire codes will be adopted and in place as of September 1 st, 2011. There are many changes to both codes. Due to the number of changes this presentation

More information

10 EXTREME BASEMENT PANELS

10 EXTREME BASEMENT PANELS 10 EXTREME BASEMENT PANELS On Granular Footings 1. The type of soil is a factor in determining foundation construction details such as footing design, backfill, and drainage provisions. Soils are classified

More information

Public Notice New BC Building Code Requirements

Public Notice New BC Building Code Requirements Public Notice New BC Building Code Requirements November 27, 2014 The City of Revelstoke Chief Building Official advises that as of December 19, 2014 a number of new BC Building Code requirements will

More information

Mention of firms, trade names, or commercial products in this document does not constitute endorsement or recommendation for use.

Mention of firms, trade names, or commercial products in this document does not constitute endorsement or recommendation for use. Radon Mitigation Standards (RMS) Office of Air and Radiation Office of Radiation and Indoor Air Indoor Environments Division (6609J) EPA 402-R-93-078, October 1993 (Revised April 1994) Disclaimer The U.S.

More information

Radon. Precautions for New Buildings

Radon. Precautions for New Buildings Radon Precautions for New Buildings 2 Properties, Occurrence and Effect of Radon Properties and occurrence Radon is a natural, ubiquitous radioactive noble gas that is colourless, odourless and tasteless.

More information

IMPROVING THE DURABILITY OF FLAT ROOF CONSTRUCTIONS Durability of flat roof construction

IMPROVING THE DURABILITY OF FLAT ROOF CONSTRUCTIONS Durability of flat roof construction IMPROVING THE DURABILITY OF FLAT ROOF CONSTRUCTIONS Durability of flat roof construction C. RUDBECK, S. SVENDSEN Technical University of Denmark, Department of Buildings and Energy, Lyngby, Denmark Durability

More information

STEP UP TO THE ENERGY STAR INDOOR AIR PACKAGE. A new opportunity for leading builders to create better environments inside and out

STEP UP TO THE ENERGY STAR INDOOR AIR PACKAGE. A new opportunity for leading builders to create better environments inside and out STEP UP TO THE ENERGY STAR INDOOR AIR PACKAGE A new opportunity for leading builders to create better environments inside and out WHY DOES INDOOR AIR QUALITY MATTER? People are increasingly concerned about

More information

Crawl Space Moisture Control

Crawl Space Moisture Control Crawl Space Moisture Control Crawl space foundations are found in many homes. Typically, these foundation types are equipped with operable vents designed to provide ventilation for moisture control. Unfortunately,

More information

Evaluation of Effectiveness of Breathe EZ Air Cleaner in Reducing Risks Associated with Indoor Radon Gas. November 20, 2012

Evaluation of Effectiveness of Breathe EZ Air Cleaner in Reducing Risks Associated with Indoor Radon Gas. November 20, 2012 PGP G L Progeny Group Ltd. Evaluation of Effectiveness of Breathe EZ Air Cleaner in Reducing Risks Associated with Indoor Radon Gas November 20, 2012 This report provides pertinent data gathered to date

More information

Training Certification Categories

Training Certification Categories Training Certification Categories Residential Residential Building Inspector structures are free from hazardous structural conditions and comply with the UCC. Duties include inspection of footings and

More information

4 EXTREME FOUNDATION PANELS

4 EXTREME FOUNDATION PANELS 4 EXTREME FOUNDATION PANELS For House Crawl Space On Concrete Footings 1. The type of soil is a factor in determining foundation construction details such as footing design, backfill, and drainage provisions.

More information

Initial House Assessments & Sealing Options:

Initial House Assessments & Sealing Options: Initial House Assessments & Sealing Options: July 2017 Dave Bohac, PE Center for Energy and Environment Ed VonThoma Building Knowledge Initial House Assessments and Sealing Options Contents Summary...

More information

PLAN CHECK CORRECTION SHEET FOR METHANE MITIGATION SYSTEMS 2014 LAPC

PLAN CHECK CORRECTION SHEET FOR METHANE MITIGATION SYSTEMS 2014 LAPC PLAN CHECK CORRECTION SHEET FOR METHANE MITIGATION SYSTEMS 2014 LAPC This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

More information

Permit Posting and Inspection Procedures

Permit Posting and Inspection Procedures Permit Posting and Inspection Procedures Boone County Area Plan Commission 116 Washington Street Room 101 * Lebanon, IN 46052 * (765) 482-3821 * www.boonecounty.in.gov/apc 1. Permit. The following permit

More information

Napa County Building Officials Coalition

Napa County Building Officials Coalition Napa County Building Officials Coalition Striving to provide clear and consistent building code information and handouts for all Napa County jursidictions. (Please check with each jursidiction for any

More information

Adding Radon Control Techniques to New Homes

Adding Radon Control Techniques to New Homes Adding Radon Control Techniques to New Homes Sponsored by: The North Dakota Department of Health North Dakota Association of Builders January 2012 Presented by: Doug Kladder Center for Environmental Research

More information

Residential Construction Minimum Required Inspections

Residential Construction Minimum Required Inspections Residential Construction Minimum Required Inspections The permit which you have been issued gives authority for work to commence. The stamped, approved plans, returned with this permit, shall be retained

More information

STANDARD SPECIFICATIONS

STANDARD SPECIFICATIONS TOWN OF COLONIE DEPARTMENT OF PUBLIC WORKS DIVISION OF PURE WATERS STANDARD SPECIFICATIONS for RESIDENTIAL SANITARY SEWER CONNECTIONS Latest Revision Date: November 2017 TABLE OF CONTENTS Section Page

More information

General Requirements for Mobile Homes

General Requirements for Mobile Homes Mobile homes shall conform in all respects to the CAN/CSA-Z240 MH Series of Standards and shall be complete structurally with the entire plumbing, electrical, and heating services installed. Prior to moving

More information

CertainTeed. Canadian Installation Guide. 3-in-1 Solution. Forms Footings Drains Foundations Vents Radon

CertainTeed. Canadian Installation Guide. 3-in-1 Solution. Forms Footings Drains Foundations Vents Radon CertainTeed Canadian Installation Guide 3-in-1 Solution Forms Footings Drains Foundations Vents Radon STEP-BY-STEP INSTRUCTIONS Rough Layout Begin with the rough layout of the required number of standard

More information

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date ORDINANCE AN ORDINANCE OF THE COMMISSION OF KNOX COUNTY, TENNESSEE RESCINDING ARTICLE III. CABO ONE- AND TWO-FAMILY DWELLING CODE, SEC. 10-56, SEC. 10-57 AND SEC. 10-58 AND ADOPTING THE 2006 INTERNATIONAL

More information