Specifications. Rated Speed Maximum number of stops. Maximum travel (ft.) 6'-11" Minimum floor height (ft.) 7'-4" 8'-0" 7'-11 1/4"

Size: px
Start display at page:

Download "Specifications. Rated Speed Maximum number of stops. Maximum travel (ft.) 6'-11" Minimum floor height (ft.) 7'-4" 8'-0" 7'-11 1/4""

Transcription

1 ASI SPEIFIATIONS APAITY: lbs ~ lbs, Rated Speed, Door Type, ar Inside & Hoistway Dimensions* 1 Specifications <Rated Speed fpm to 500fpm> & Rear <Rated Speed fpm and fpm> & Rear (ft./in.)* 5,7 5'-5 1/2" <Rated Speed 400fpm and 500fpm> & Rear (ft./in.)* 5, 7 6'-3" 6'-5" Door type* 2 SS SS or O O fpm 14'-3" 15'- 400fpm WT Location Rear Side Rear 15'-8 11/16" 16'-6 11/16" ar inside clear dimensions Entrance Minimum hoistway dimensions* 3 Width Depth width : Width H: Depth (ft./in.) (ft./in.) (ft./in.) (ft./in.)* 4 (ft./in.)* 7 6'-8" 7'-8" Minimum hoistway dimensions* 3 15'-3" 16'-8 11/16" (ft./in.)* 5, 7 5'-11 1/2" 6'- Minimum hoistway dimensions* 3 OH* 6, 8 (ft./in.) (ft./in.)* 5, 7 7'-5" 7'-6 1/2" 4'-3 3/ 4'-8 3/ 5'-4 3/ 5'-8 3/16" 5'-4 3/ fpm 14'-6" 15'-5" 500fpm OH* 6, 8 (ft./in.) 3'-6" 15'-11 11/16" 16'-10 11/16" 16'- 17'-6 11/16" 7'-6" 8'-6" 9'-7" 9'-7" 6'-1 7'- 7'-11 1/ *1. The contents of these tables are standard specifications. They are based on ASME A17.1 and applicable to both seismic and non-seismic zones. Please consult your local sales office for other specifications. ( EEDSALES@meus.mea.com) *2. SS: Single-Slide door, O: enter-open doors *3. Hoistway dimensions (, H,, OH) are for standard specifications. *4. The dimensions indicate for one car. For dimensions of 2 and 3 car, please refer to left table. dimension in 2 and 3 car layout is same as of 1 car. These are values after waterproofing and do not include plumb tolerance. *5. Pit depth in this drawing is obtained when floor recess is 3/. When floor recess is greater than 3/, extend pit depth as well. Max. floor recess is 1 1/. *6. The minimum OH dimensions are obtained on condition that: A. =. OH dimensions does not include the hoisting beams.. Please consult your structural engineer for hoisting beam sizing (typically a 6" to 8" beam plus 2" gap on top of the beam). *7. If occupied space below hoistway is provided, required hoistway dimensions will be changed. Please consult your local sales office for details. *8. For alifornia projects, please add 2 to OH dimensions shown in the table above for elevator travel between and Rated Speed Maximum number of stops Maximum travel (ft.) Minimum floor height (ft.) dimension for 2 and 3 ar & Rear ~ fpm 7 dimension (ft./in.) 2 ar 3 ar 15'- 23'-2" 17' '-10" Power Feeder Data for One ar* Traction motor (HP) '-2" 29'-5" fpm 98'-5" FLU (A) '-1 * 9 400fpm urrent at 480V* '-5" For travel greater than shown above, please consult your local sales office or EEDSALES@meus.mea.com. - FLAcc (A) fpm Power supply capacity (kva) Heat emission of control panel (TU/hr) *9. Some of specifications require more than the value 8'-1 as a minimum height. Please consult your local sales office if floor height is less than 8'-1. *10. If power supply voltage is other than 480V, FLU and FLAcc current are obtained by the following formulas. FLU, FLAcc current (A) at E = (urrent at 480V) x (480 / E) (E: Power supply voltage (V)) *11. Start / hour (time) is as follows. fpm: 0 times fpm: 150 times 400 and 500fpm: 180 times 13 14

2 ASI LAYOUTS APAITY: lbs ~ lbs APAITY: lbs Hoistway Plan (example) & Rear Hoistway Plan FOR 1 AR FOR 2 AR FOR 3 AR 7'-2" Shown for Single-Slide door Shown for enter-open doors H H H : Refer to page 21. Overhead OH Refer to page 14. Pit depth Minimum floor height 8'-1 Hoisting beams ab height (STD) FOR 1 AR FOR 2 AR Shown for Single-Slide door H Shown for enter-open doors H Overhead OH Refer to page 14. Pit depth : Refer to page 21. Minimum floor height 8'-1 Hoisting beams ab height (STD) Shown for enter-open doors 15 16

3 ASI SPEIFIATIONS APAITY: lbs ~ lbs, Rated Speed, Door Type, ar Inside & Hoistway Dimensions* 1 Specifications <Rated Speed fpm and fpm> Service & Rear <Rated Speed fpm and fpm> onfiguration onfiguration onfiguration Service & Rear Door type* 2 2S (ft./in.)* 5,7 6'- 6'- WT Location Side fpm 15'- 15'-2" ar inside clear dimensions Entrance Minimum hoistway dimensions* 3 Width width : Width (ft./in.) (ft./in.) (ft./in.)* 4,7 5'-10" 5'-10" Depth (ft./in.) 7'-3 1/ 7'-11 1/ 8'-6 1/ 8'-4 1/ 8'-7" 8'-5" Minimum hoistway dimensions* 3 16'-6 11/16" 16'-7 11/16" (ft./in.)* 5,7 6'- 6'-2"* 8 6'- 4'-6" 4'-6" fpm 15'-5" 15'-10" 8'-7 1/2" 8'-9 1/2" 8'-7 1/2" 8'-9 1/2" 16'-10 11/16" 17'-3 11/16" H: Depth (ft./in.)* 7 9'- 9'-8" 10'-3" 10'- 10'-8 3/ 11'-3 3/ 11'-1 3/ *1. The contents of these tables are standard specifications. They are based on ASME A17.1 and applicable to both seismic and non-seismic zones. Please consult your local sales office for other specifications. ( EEDSALES@meus.mea.com) *2. 2S: 2-Speed side-open doors *3. Hoistway dimensions (, H,, OH) are for standard specifications. *4. The dimensions indicate for one car. For dimensions of 2 and 3 car, please refer to left table. dimension in 2 and 3 car layout is same as of 1 car. These are values after waterproofing and do not include plumb tolerance. *5. Pit depth in this drawing is obtained when floor recess is 3/. When floor recess is greater than 3/, extend pit depth as well. Max. floor recess is 1 1/. *6. The minimum OH dimensions are obtained on condition that: A. =. OH dimensions does not include the hoisting beams.. Please consult your structural engineer for hoisting beam sizing (typically a 6" to 8" beam plus 2" gap on top of the beam). *7. If occupied space below hoistway is provided, required hoistway dimensions will be changed. Please consult your local sales office for details. *8. If the travel is below 98'-5", some reduction of pit depth is available. Please consult your local sales office for details. Maximum number of stops Maximum travel (ft.) Minimum floor height (ft.) dimension for 2 and 3 ar Service / & Rear Entrance width (ft./in.) 4'-6" dimension (ft./in.) 2 ar 3 ar 17'-7" 17'-1 26'-6 1/2" 27'-0 1/2" Power Feeder Data for One ar* 11 fpm fpm 196'-10" 8'-1 * 9 For travel greater than shown above, please consult your local sales office or EEDSALES@meus.mea.com. Traction motor (HP) FLU (A) urrent at 480V* 10 FLAcc (A) *9. Some of specifications require more than the value 8'-1 as a minimum height. Please consult your local sales office if floor height is less than 8'-1. *10. If power supply voltage is other than 480V, FLU and FLAcc current are obtained by the following formulas. FLU, FLAcc current (A) at E = (urrent at 480V) x (480/ E) (E: Power supply voltage (V)) *11. Start / hour (time) is as follows. fpm: 0 times fpm: 150 times Power supply capacity (kva) Heat emission of control panel (TU/hr)

4 ASI LAYOUTS APAITY: lbs ~ lbs APAITY: lbs ~ lbs & Rear Hoistway Plan (example) Hoistway Plan (example) FOR 1 AR FOR 2 AR H H Refer to page 18. Overhead OH Pit depth : Refer to page 22. 8'-1 Hoisting beams ab height (STD) FOR 1 AR FOR 2 AR H H Refer to page 18. Overhead OH Pit depth : Refer to page 22. Minimum floor height 8'-1 Hoisting beams ab height (STD) 19 20

5 AR HITH EAM APAITY: lbs ~ lbs APAITY: lbs ~ lbs (Min. 4 1/8") Hoistway plan R For oncrete and Masonry Wall onstruction A A For Dry Wall onstruction Min. 2 15/16" HH HH = > 5 1/2" < 5 1/2" 1 (Min. 4 1/8") Section - Hoistway section Through hole for car hitch beam Height of through hole for car hitch beam [HH] HH* (ft./in.) lbs~lbs lbs 11'-10 1/8" '-1 1/8" '-4 7/8" '-8 15/16" 400 '-10 1/8" '-7 1/8" - *1: The HH dimensions are obtained when canopy height =. *2: For alifornia projects, please add 2 to HH dimensions shown in the table above for elevator travel between and Reaction loads <Rated Speed fpm and fpm> & Rear Embedded steel plate Min. 2 15/16" HH Static Dynamic <Rated Speed 400fpm and 500fpm> Static Dynamic & Rear (Min.4 1/8") 1 R Static Dynamic /8" Section R Static Dynamic Through hole for car hitch beam 8"X13"X3/8" For oncrete and Masonry Wall onstruction For Dry Wall onstruction A A (Min. 4 13/16") Hoistway plan R Min. 3 15/16" HH HH Hoisting beam = > 5 7/8" < 5 7/8" (Min. 4 13/16" ) 1 Hoistway section Section - Through hole for car hitch beam Height of through hole for car hitch beam [HH] HH* 1 (ft./in.) '-4 7/8" '-8 15/16" *1: The HH dimensions are obtained when canopy height = 8-0. Reaction loads & Rear Embedded steel plate WT Location Min. 3 15/16" HH Side R Static Dynamic Static Dynamic (Min.4 13/16") 1 7 7/8" Section - Through hole for car hitch beam 8"X13"X3/8" 6 1/2" 6 1/2" HH 3 15/16" 2-3/X2 1/16" Elongated holes HH 3 15/16" 2-3/X2 1/16" Elongated holes Section - Section - Section - Section

6 ENTNE LAYOUTS For oncrete and Masonry Wall onstruction For Dry Wall onstruction Single-Slide door (section -) Single-Slide door (section -) enter-open doors (section -) 2-Speed side-open doors (section - ) /2 enter-open doors (section -) 2-Speed side-open doors (section -) 6 1/2 23

Freight Elevator Series GFM-T

Freight Elevator Series GFM-T Freight Elevator Series GFM-T Mitsubishi Freight Elevators Can Improve our Goods-Handling Ability Elevator Selection 1. Rated capacity and car size What is the maximum weight or size of goods to be transported

More information

Introduction. Disclaimer. Table of contents

Introduction. Disclaimer. Table of contents Updated July 18, 2012 Introduction The Cambridge Elevating Limited-Use / Limited-Application Elevator is designed to service schools, libraries, low rise, low occupancy commercial buildings, churches and

More information

Machine-roomless holeless hydraulic elevator

Machine-roomless holeless hydraulic elevator Machine-roomless holeless hydraulic elevator Design freedom for low-rise buildings. The HydroFit system: a machine-roomless holeless hydraulic elevator. Otis HydroFit Delivers: Design freedom Minimal

More information

MACHINE ROOM-LESS PERFORMANCE IN A HYDRAULIC ELEVATOR HOISTWAY. KONE EcoSpace

MACHINE ROOM-LESS PERFORMANCE IN A HYDRAULIC ELEVATOR HOISTWAY. KONE EcoSpace MACHINE ROOM-LESS PERFORMANCE IN A HYDRAULIC ELEVATOR HOISTWAY KONE EcoSpace The revolutionary machine room-less elevator concept KONE s machine room-less (MRL) technology eliminates the need for a machine

More information

2. Cab, interior finishes, control panel and facings including cab doors. 3. Fire rated hoistway doors, sills, and frames.

2. Cab, interior finishes, control panel and facings including cab doors. 3. Fire rated hoistway doors, sills, and frames. PART 1: GENERAL 1.01 Summary Section Includes: 1. Electric traction Dumbwaiter system. 2. Cab, interior finishes, control panel and facings including cab doors. 3. Fire rated hoistway doors, sills, and

More information

SECTION HYDRAULIC DRIVE MACHINE ROOM (MR) RESIDENTIAL ELEVATORS

SECTION HYDRAULIC DRIVE MACHINE ROOM (MR) RESIDENTIAL ELEVATORS SECTION 14 20 10 HYDRAULIC DRIVE MACHINE ROOM (MR) RESIDENTIAL ELEVATORS PART 1 - GENERAL 1.1 CONDITIONS AND REQUIREMENTS A. The General Conditions, Supplementary Conditions, and Division 01 General Requirements

More information

Raised Basement. Mechanical Installation Guide

Raised Basement. Mechanical Installation Guide R Raised Basement Mechanical Installation Guide Ensure masonry work is correct. If recessed, the depth must be 14 inches deep unless otherwise specified for a custom application. Width and length may vary

More information

Residential Elevator Design Guide

Residential Elevator Design Guide Residential Elevator Design Guide All Models - Elmira, Heritage & Cambrian 1261 Industrial Rd Cambridge, ON N3H 4W3 (p) 1.800.265.3579 (p) 519.653.4222 (fl 519.653.9927 www.cambridgeelevating.com Table

More information

You dream it. We build it. ELEVATORS

You dream it. We build it. ELEVATORS You dream it. We build it. ELEVATORS RAM can help you tailor your Crystal Elevator to be a focal point in your home with stunning architectural features or it can be tucked away for seamless and simple

More information

Savaria Eclipse Home Elevator

Savaria Eclipse Home Elevator Savaria Eclipse Home Elevator Luxury and convenience customized for you About Savaria In business for over 30 years, Savaria designs, engineers and manufactures products to help people gain personal mobility.

More information

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

1. Vertical reciprocating conveyor, Hydraulic straddle VRC. PART 1: GENERAL 1.01 Section Includes: 1. Vertical reciprocating conveyor, Hydraulic straddle VRC. a. Machine, controller, platform, structural steel hoist frame. b. Wire mesh enclosure and gates. Related

More information

Cantilevered Rail System

Cantilevered Rail System Knight Global's Cantilevered Rail Systems are designed to eliminate the need for a four post floor structure system. It provides an alternative to workstations with minimal floor space. A wide range of

More information

Beautifully Crafted, Expertly Engineered, Thoughtfully Constructed

Beautifully Crafted, Expertly Engineered, Thoughtfully Constructed Symmetry Residential Home Elevator Systems Table of Contents Component Identification...3 Equipment for Symmetry Residential...5 Typical Hoistway Options...8 Typical Hoistway Construction...11 Typical

More information

VIBRAPAC 3 AT A TIME INSTALLATION MANUAL F9801US OCTOBER 1999 US$250

VIBRAPAC 3 AT A TIME INSTALLATION MANUAL F9801US OCTOBER 1999 US$250 VIBRAPAC 3 AT A TIME 466365F9801US OCTOBER 1999 US$250 World Headquarters 801 Johnson St. Alpena, Michigan, 49707 U.S.A. Phone (517) 354-4111 COMPANY NAME:... SERIAL NUMBER:... ASSEMBLY NUMBER:... WIRING

More information

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd RAM ELEVATORS Elevator Electrical Planning Guide This guide is intended for people with an understanding of electricity. If you are not, please consult a licensed electrician as errors in application of

More information

Electric Service Standards

Electric Service Standards V: 1 of 6 A. Padmounted Requirements Complete requirements are contained in FPL specifications given to Customers for individual projects. Typical pad mounted transformer requirements include, but are

More information

DICTATOR Lift Shaft System

DICTATOR Lift Shaft System DICTATOR Lift Shaft System The Modular Lift Shaft System, also for Retrofitting Certified According to EN 1090 A lift is becoming more and more important for daily life, not only in newly constructed buildings

More information

Design Guidelines Technology

Design Guidelines Technology VERTICAL TRANSPORTATION Design Guidelines Technology 7/1/09 Building Insight 1 Elevator Design Guidelines AIA Los Angeles is a Registered Provider with The American Institute of Architects Continuing Education

More information

Buderus SB745WS/1550 Stainless Steel Condensing Boiler

Buderus SB745WS/1550 Stainless Steel Condensing Boiler Stainless Steel Condensing Boiler Engineering Submittal Sheet Boiler Components R Engineering Specifications The boiler(s) shall have a full three pass fire tube design to allow complete combustion of

More information

SERVICES. About Us. EDS Company Ethos. Services. Categories

SERVICES. About Us. EDS Company Ethos. Services. Categories About Us EDS don t just make stuff. We use our engineering and product development experience to design and develop innovative, practical and cost effective solutions. We work closely with our customers

More information

UNIVERSITY OF ALASKA FAIRBANKS DIVISION 14 - CONVEYING EQUIPMENT DESIGN STANDARDS SECTION

UNIVERSITY OF ALASKA FAIRBANKS DIVISION 14 - CONVEYING EQUIPMENT DESIGN STANDARDS SECTION PART 1 - GENERAL 1.01 Elevator manufacturer to provide equipment and installation warranty and maintenance services for at least one year after acceptance. This requires routine monthly inspection, emergency

More information

Planning Guide (Imperial)

Planning Guide (Imperial) P.A.L.TM VERTICAL PLATFORM LIFT Planning Guide (Imperial) For Vertical Platform Lifts P.A.L. - S (Unenclosed or Hoistway Models) P.A.L. - EN (Fully Enclosed Models) Applicable Codes: ASME A18.1 CAN/CSA

More information

ELEVATORS, LULAS AND PLATFORM LIFTS

ELEVATORS, LULAS AND PLATFORM LIFTS ELEVATORS City of Los Angeles Plan Check No: 1. Elevators provided for passengers shall comply with 11B-407 Elevators. Where multiple elevators are provided, each elevator shall comply with 11B-407 Elevators;

More information

STAINLESS STEEL SHEETS

STAINLESS STEEL SHEETS STAINLESS & NICKEL ALLOY CHATHAM STEEL CORPORATION 59 STAINLESS STEEL SHEETS TYPE 04, 04L, 6, 6L No. 2B Finish Cold Rolled, Annealed *No. 2D Finish No. Finish Polished One Side No. 4 Finish Polished One

More information

Vertical Transportation Planning Retail/Mixed-Use

Vertical Transportation Planning Retail/Mixed-Use Fortune Consultants LTD Elevator Consulting Vertical Transportation Planning Retail/Mixed-Use This paper is to provide design guidance for the initial planning of vertical transportation in either a standalone

More information

Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout

Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout Building Department 200 W. Oak Street 3 rd Floor Fort Collins, CO 80521 970-498-7700 DEFINITIONS High Wind Areas Those areas

More information

SECTION ALTERNATES

SECTION ALTERNATES SECTION 01 23 00 - ALTERNATES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco

More information

Click to edit Master text styles

Click to edit Master text styles LB, GB & OB Zoning District Architectural and Building Design Standards GB & LB OB Overview of items to consider: Design Standards General Requirements 1. Buildings should Second be parallel to street

More information

Power Zone Center. Your solution for power distribution and control systems

Power Zone Center. Your solution for power distribution and control systems Power Zone Center Your solution for power distribution and control systems The Strength of One Powerful When you need to install a new power distribution center in your facility, you need it done in fastest

More information

Buderus SB625WS/640 Stainless Steel Condensing Boiler

Buderus SB625WS/640 Stainless Steel Condensing Boiler Stainless Steel ondensing Boiler Engineering Submittal Sheet Boiler omponents R Engineering Specifications The boiler(s) shall have a full three pass fire tube design to allow complete combustion of the

More information

SPECIFICATIONS. Part 1- General

SPECIFICATIONS. Part 1- General 1.1 SCOPE Part 1- General To furnish all labor, materials and equipment necessary or required to fully complete the installation of the elevator as shown on the drawings and specifications. This suggested

More information

Full-Cab A18.1/B355 Lifts An Alternative to LU/LA Elevators

Full-Cab A18.1/B355 Lifts An Alternative to LU/LA Elevators Continuing Education Full-Cab A18.1/B355 Lifts An Alternative to LU/LA Elevators How to differentiate between lifts and elevators in North America and choose between a traditional or LU/LA elevator, stairlift,

More information

Enhanced energy-efficiency, safety and design contextualism drive forward our mission to create the escalators of the future, utilizing our advanced

Enhanced energy-efficiency, safety and design contextualism drive forward our mission to create the escalators of the future, utilizing our advanced ESCATORS For USA Enhanced energy-efficiency, safety and design contextualism drive forward our mission to create the escalators of the future, utilizing our advanced technologies. 1 2 Principle Based on

More information

CHEMICAL /4" 3/8" to 5/8" /8" 3/4" to 1-1/4" 1 10

CHEMICAL /4 3/8 to 5/8 /8 3/4 to 1-1/4 1 10 194 ASTM A193 GRADE B7 HIGH-STRENGTH CARBON, ZINC PLATED (ASTM B 633 YELLOW DICHROMATE) B7 (AISI 414) anchor rod is supplied with nuts meeting the requirements of ASTM Specification A 194, Grade 2H (ASTM

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 14 2100 - MACHINE-ROOM-LESS (MRL) TRACTION ELEVATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING 7160 Krick Rd., Walton Hills, OH 44146 800-321-3827 - Tel 440-439-8650 - Fax 440-439-6889 SECTION 12 48 16 ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING PART 1. GENERAL 1.01 SUMMARY: This section includes

More information

- 2 - GUIDELINES FOR SAFE UNLOADING OF 20 LINED BOX CONTAINERS CONTENTS

- 2 - GUIDELINES FOR SAFE UNLOADING OF 20 LINED BOX CONTAINERS CONTENTS GUIDELINES FOR SAFE UNLOADING OF 20 FOOT LINED ISO BOX CONTAINERS V1 September 2016 - 2 - CONTENTS 1: INEOS O&P CUSTOMER COMMITMENT 3 2: INEOS O&P SAFETY POLICY 4 3:TYPE OF DELIVERY 5 4:RISKS 8 4: UNLOADING

More information

Check-List of General Building Services

Check-List of General Building Services Check-List of General Building Services AREAS Land Area 2 Acres Usage IT / ITES plus facilities Build up Area Office space 2,35,001 sq.ft. plus double basement of 1,03,374sq.ft. Floor Plate 30,000sq.ft

More information

Tri-Star MAX Spill Containment System - 7' x 16' x 9" Panel

Tri-Star MAX Spill Containment System - 7' x 16' x 9 Panel Export date: Sun Dec 10 6:41:03 2017 / +0000 GMT Tri-Star MAX Spill Containment System - 7' x 16' x 9" Panel SKU: CST-MAX071609 Product Categories: Tri-Star MAX - Fuel Tank Containment - Tanker Containment

More information

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION PLATE CONNECTED WOOD TRUSSES SECTION 06173 PLATE CONNECTED WOOD TRUSSES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Shop fabricated wood trusses for roof and floor framing. 2. Bridging, bracing, and anchorage. B. Related Sections:

More information

CHAPTER 9 STAIR CASES 9.1 GENERAL FEATURES 9.2 TYPES OF STAIR CASES

CHAPTER 9 STAIR CASES 9.1 GENERAL FEATURES 9.2 TYPES OF STAIR CASES CHAPTER 9 STAIR CASES 9.1 GENERAL FEATURES Stair cases are provided for connecting successive floors. It is comprised with flights of steps with inter mediate landings which provides rest to the user and

More information

BUILDING STRENGTH ACCUBRACE TOTAL BRACING SYSTEM CONCRETE CONSTRUCTION SOLUTIONS

BUILDING STRENGTH ACCUBRACE TOTAL BRACING SYSTEM CONCRETE CONSTRUCTION SOLUTIONS BUILDING STRENGTH ACCUBRACE TOTAL BRACING SYSTEM CONCRETE CONSTRUCTION SOLUTIONS A Total Bracing System An integrated, in-line total bracing system designed to decrease labor costs and increase project

More information

DIVISION 14 CONVEYING SYSTEMS

DIVISION 14 CONVEYING SYSTEMS DIVISION 14 CONVEYING SYSTEMS A. GENERAL TO ALL ELEVATORS AND EQUIPMENT 1. ALL elevator equipment, without exception, installed on this campus shall be non- proprietary. a) Any elevator company shall be

More information

Loads and Load Paths. "Architecture is inhabited sculpture." -Constantin Brancusi

Loads and Load Paths. Architecture is inhabited sculpture. -Constantin Brancusi Loads and Load Paths "Architecture is inhabited sculpture." -Constantin Brancusi Loads and Load Paths Structural Design Design Loads Dead Load Live Load Snow Load Lateral Loads Load Types Load Combinations

More information

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS SECTION 08 32 20 CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

Section Subparts T. Cleveland State University Work Zone Safety and Efficiency Transportation Center. Demolition

Section Subparts T. Cleveland State University Work Zone Safety and Efficiency Transportation Center. Demolition Demolition 1926.252(a) Whenever materials are dropped more than 20 feet to any point lying outside the exterior walls of the building, an enclosed chute of wood, or equivalent material, shall be used.

More information

Elevating your standard of living

Elevating your standard of living Elevating your standard of living March 2015 WELCOME TO REI Dear Prospective Client, I would like to personally thank you for considering Residential Elevators, Inc. (REI) for your home elevator purchase.

More information

ASSEMBLY INSTRUCTION.

ASSEMBLY INSTRUCTION. INSTALLATION OF BUILT-IN BOX brickwork plastering sealing tape built-in box with flange height adjustment sealing tile adhesive tiles LED technology cover silicon joints aluminium profiles The built-in

More information

UNIFIED FACILITIES CRITERIA (UFC) ELEVATORS

UNIFIED FACILITIES CRITERIA (UFC) ELEVATORS UNIFIED FACILITIES CRITERIA (UFC) ELEVATORS PRE-DECISIONAL; DRAFT UNIFIED FACILITIES CRITERIA (UFC) ELEVATORS Any copyrighted material included in this UFC is identified at its point of use. Use of the

More information

Quentor Ltd. Q-Shacks CASES. Clearly a case of excellence

Quentor Ltd. Q-Shacks CASES. Clearly a case of excellence Quentor Ltd Q-Shacks CASES Clearly a case of excellence Introduction Q-Shacks were developed by Quentor as lightweight freight solutions for world-wide air travel. The Q-Shack is a lightweight module that

More information

Manufacturing Facilities Proposal

Manufacturing Facilities Proposal Manufacturing Facilities Proposal Construction proposal To assist business owners with expansion projects, Wisconsin Public Service has compiled information and renderings of common building types in business

More information

Installation Guide and Safety Manual

Installation Guide and Safety Manual Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips) REQUIRED FURRING CHANNEL REQUIRED FURRING CHANNEL* 1 4" 2 2" Minimum f" Gauge:...25 Gauge With Hemmed Edge (Do Not

More information

OVERHEAD SERVICE DISTRIBUTION

OVERHEAD SERVICE DISTRIBUTION OVERHEAD SERVICE DISTRIBUTION Overhead Service Carriers Our service distribution solutions have been designed to be compatible with a wide range of furniture and fume hood products, allowing you to create

More information

Decommissioning Group Ketut Kamajaya

Decommissioning Group Ketut Kamajaya Decommissioning Group Ketut Kamajaya Contents of presentation Briefly history of Bandung TRIGA reactor Location of the facility Decommissioning options Characterization of System, Structure and Component

More information

hors Anc Eaton's B-Line series fasteners 183

hors Anc Eaton's B-Line series fasteners 183 183 Glossary Prefix - Description Screw Dia. Length Suffix ACB - Concrete Anchor Bolt 4 - #4 75-3 /4" AN - Acorn Nut ACPD - Bang-IT 6 - #6 81-13 /16" CH - Combo Head ACPW - Wood-Knocker 8 - #8 87-7 /8"

More information

Part Rod Design Maximum Iron. No. Size B C Load Pipe Size Per UL Approx. Wt./100. Part Rod Design Maximum Iron

Part Rod Design Maximum Iron. No. Size B C Load Pipe Size Per UL Approx. Wt./100. Part Rod Design Maximum Iron eam lamps 351L - Steel -lamp With Locknut (TOLO ig. 64) Size Range: 3 /8"-16 thru 7 /8"-9 rod Material: Steel unction: or attachment to I-beams, channels, and wide flange beams where the thickness does

More information

Florida Accessibility Code for Building Construction

Florida Accessibility Code for Building Construction Florida Accessibility Code for Building Construction Accessibility Training Course Florida Building Commission 1 Introduction Course will review the Florida Accessibility Code for Building Construction

More information

Schindler CLIMB LiftTM Transportation Solution For Your Construction Site

Schindler CLIMB LiftTM Transportation Solution For Your Construction Site Transportation Solution For Your Construction Site Speed up construction Save expense Safe operation with higher transportation efficiency from material through to manpower under all conditions Fast development

More information

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

RESIDENTIAL CONSTRUCTION New Dwellings and Additions How to Obtain a Building Permit For RESIDENTIAL CONSTRUCTION New Dwellings and Additions MIAMI COUNTY, KANSAS CODE SERVICES DEPARTMENT 201 South Pearl Street, Suite 201 Paola, Kansas 66071-1777 Phone:

More information

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project. SECTION 14651 FREE STANDING JIB CRANE ***** Gorbel, Inc. manufacturers a broad range of material handling cranes including monorail, bridge, gantry, and jib cranes. Numerous work station and industrial

More information

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members. SECTION 10155 TOILET COMPARTMENTS PART 1 GENERAL 1.1 SECTION INCLUDES A. Plastic laminate partitions. 1.2 RELATED SECTIONS A. Section 05500 - Metal Fabrications: Concealed steel support members. B. Section

More information

For the 2008 Code, the minimum clear distances were revised to reflect an accurate metric conversion (also known as a soft conversion).

For the 2008 Code, the minimum clear distances were revised to reflect an accurate metric conversion (also known as a soft conversion). II. 600 Volts, Nominal, or Less 110.26 Spaces About Electrical Equipment. Sufficient access and working space shall be provided and maintained about all electrical equipment to permit ready and safe operation

More information

Building a Detached Garage

Building a Detached Garage Building a Detached Garage A Guide through the Process The purpose of this handout is to help you prepare a complete building permit application package and answer many of your FAQ s for a detached garage

More information

LIST OF STRUCTURAL DRAWINGS FOR THE PROPOSED G+3 CLASS IV QUARTER (TWO BEDROOM) AT PHUNTSHOLING

LIST OF STRUCTURAL DRAWINGS FOR THE PROPOSED G+3 CLASS IV QUARTER (TWO BEDROOM) AT PHUNTSHOLING STRUCTURAL DRAWINGS LIST OF STRUCTURAL DRAWINGS FOR THE PROPOSED G+ CLASS IV QUARTER (TWO EDROOM) AT PHUNTSHOLING DRG. NO. DRAWING TITLE DATE OF ISSUE STR/00 STR/00 STR/0 STR/0 STR/0 STR/04 STR/05 STR/06

More information

Structural vs Nonstructural Members. Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures

Structural vs Nonstructural Members. Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures Structural vs Nonstructural Members Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures Behavior of Cold-Formed Steel Members STEEL DESIGN SPECIFICATIONS Type of steel Specification

More information

The advantages of resistance welding versus Mig welding are: Weld consistency Weld strength Floor cleanliness.

The advantages of resistance welding versus Mig welding are: Weld consistency Weld strength Floor cleanliness. self-supported tri Flooring Systems Self-Supported TriDEK floors have a truss system that eliminates the need for floor frames or other support methods. TriDEK self-supported floors can be used to span

More information

Material Report - [Trade Contractors] for plan: [E:\SoftPlan14\Projects\Sample Drawings.spf\2-Storey sqft.spf] Page 1 of 5

Material Report - [Trade Contractors] for plan: [E:\SoftPlan14\Projects\Sample Drawings.spf\2-Storey sqft.spf] Page 1 of 5 Material Report - [Trade Contractors] for plan: [E:\SoftPlan14\Projects\Sample Drawings.spf\2-Storey 01-2320 sqft.spf] Page 1 of 5 PREPARATION PRELIM PERMITS & FEES Building Permit 1 each 2200.00 _ 2200.00

More information

SECTION SIXTEEN VERTICAL CIRCULATION

SECTION SIXTEEN VERTICAL CIRCULATION Source: BUILDING DESIGN AND CONSTRUCTION HANDBOOK SECTION SIXTEEN VERTICAL CIRCULATION Steven D. Edgett and Allen M. Williams Edgett-Williams Consulting Group, Mill Valley, California Circulation, as usually

More information

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project. GORBEL PRODUCT SPECIFICATIONS 2010 Gorbel, Inc., P.O., Box 593, Fisher, New York 14453-0593 PHONE: 800-821-0086, FAX: 585-924-6273; WEBSITE: www.gorbel.com November SECTION 41 22 31PRIVATE FREE STANDING

More information

A/E Design Deliverable Checklist

A/E Design Deliverable Checklist A/E Design Deliverable Checklist Design deliverables for the Design Development phase shall include all items listed in the Design Development column as well as those all items listed in the Schematic

More information

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT 1 East Franklin Street Phone: 301-790-4163 Third Floor Hagerstown, MD 21740 Fax: 301-791-2650 BUILDING PERMIT APPLICATION FOR RESIDENTIAL ACCESSORY

More information

TABLE OF CONTENTS 4.5.1

TABLE OF CONTENTS 4.5.1 TABLE OF CONTENTS General Mezzanine Information and Specifications... 2 SM0010PE Mezzanine Plan Information... 3 Information Required for Mezzanine Structures... 4 Floor And/Or Mezzanine Design Information

More information

FEATURES APPLICATIONS. Technical data sheet SSW - STEEL STRONG-WALL FOR TIMBER FRAME RACKING RESISTANCE.

FEATURES APPLICATIONS. Technical data sheet SSW - STEEL STRONG-WALL FOR TIMBER FRAME RACKING RESISTANCE. The Steel Strong-Wall is a corrugated steel panel which is designed to be fixed directly to the concrete foundations of a building, within the external or internal wall, via a bolted connection. FEATURES

More information

The Building Codes A.R.E. Building Design and Construction Exam Prep

The Building Codes A.R.E. Building Design and Construction Exam Prep Know Thy Codes! The Building Codes Building Codes The Code of Hammurabi 4000bc Developed 19 th and 20 th c. Codes define what you can and can t do Allowable area and height based on degree of danger Fire

More information

Applying the Building Code During Design

Applying the Building Code During Design Applying the Building Code During Design A Step-By-Step Process AIA Learning Units The Salt Lake City CSI Chapter is a Registered Provider with The American Institute of Architects Continuing Education

More information

Child Friendly Schools in Rwanda

Child Friendly Schools in Rwanda Child Friendly Schools in Rwanda Typical drawings of school building and toilet block Approved by MINEDUC/UCEFS Eng. Warren Habimana UNICEF Rwanda PO Box 381, Kigali Education section: tel. +250 592750-55

More information

Following are the NMHC/NAA Recommendations for the ICC Online Consensus Voting which opens on February 8 th, 2016:

Following are the NMHC/NAA Recommendations for the ICC Online Consensus Voting which opens on February 8 th, 2016: Following are the NMHC/NAA Recommendations for the ICC Online Consensus Voting which opens on February 8 th, 2016: These recommendations are only for those issues that are of concern to the multifamily

More information

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division GARAGES/ONE-STORY City of Grand Rapids Building Safety Division 218-326-7601 www.cityofgrandrapidsmn.com This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building

More information

FREIGHT ELEVATOR. Safe and reliable control system. Variable Voltage Variable Frequency (VVVF) traction machine. Wide door opening

FREIGHT ELEVATOR. Safe and reliable control system. Variable Voltage Variable Frequency (VVVF) traction machine. Wide door opening FREIGHT ELEVATOR Wide door opening FUJI-YIDA freight elevator possesses multi-panel door to get the widest door opening, which will facilitate the passing in and out of large goods. Light Curtain Protection

More information

Cold-Formed Steel Special Bolted Moment Frames: Cyclic Testing and Numerical Modeling of Moment Connections

Cold-Formed Steel Special Bolted Moment Frames: Cyclic Testing and Numerical Modeling of Moment Connections Cold-Formed Steel Special Bolted Moment Frames: Cyclic Testing and Numerical Modeling of Moment Connections by Chia-Ming Uang 1, Jong-Kook Hong 2, Atsushi Sato 3 and Ken Wood 4 ABSTRACT Cyclic tests on

More information

Concrete Block Machines Typical Fixed Block Machine

Concrete Block Machines Typical Fixed Block Machine SEAOG 2016 Masonry Workshop Concrete Masonry Units and Terminology Concrete Masonry in Georgia Georgia World Congress Center Reference: Inspector s Handbook Masonry Institute of America Roy Keck, FACI

More information

ZS880 Linear Shower Drain Installation Instructions

ZS880 Linear Shower Drain Installation Instructions Introduction PATENT PENDING The Zurn ZS880 Stainless Steel Linear Shower Drain incorporates a simple approach to bathroom shower design, when compared to traditional point-drain applications. The linear

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 14 2410 - HYDRAULIC FREIGHT ELEVATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Hansen Pole Buildings Planning Guide. Toll Free / Toll Free FAX

Hansen Pole Buildings Planning Guide. Toll Free / Toll Free FAX Hansen Pole Buildings Planning Guide Toll Free 866-200-9657 / Toll Free FAX 866-200-9658 While we strive to earn your business, whether you purchase from us or not, we would hope you would utilize this

More information

Inlets & Catch Basins

Inlets & Catch Basins A Delivering Reliability Inlets & Catch Basins Water-Conveyance & Drainage A Environmentally Responsible Oldcastle Precast to the Rescue All of our products are produced in a controlled environment helping

More information

Types Of Roofs - Vault

Types Of Roofs - Vault 1 Types Of Roofs - Vault Implementation Of the Concrete On Vault Implementation Of Vault Earthquake Damage 2 Types Of Roofs - Joist And Block 3 Types Of Coverage Roofs-Composite 4 5 Building Structure

More information

Concrete Plant International

Concrete Plant International Concrete Plant International Worldwide English Edition AUGUST 2014 4 NEWS Extensive research confirms the safety of hollow core floors under fire CONCRETE TECHNOLOGY Production System for Precast concrete:

More information

Elevator Product Guide

Elevator Product Guide levator echnology levator roduct uide levator systems, options and finishes catalog 2 3 thyssenkrupp moves people the future of urban mobility. View from ne World rade enter In 40 short years, we ve become

More information

HOTEL NORTHEAST U.S. JORDAN RUTHERFORD STRUCTURAL OPTION FACULTY ADVISOR DR. THOMAS BOOTHBY AE SENIOR THESIS APRIL 8, 2013

HOTEL NORTHEAST U.S. JORDAN RUTHERFORD STRUCTURAL OPTION FACULTY ADVISOR DR. THOMAS BOOTHBY AE SENIOR THESIS APRIL 8, 2013 HOTEL NORTHEAST U.S. JORDAN RUTHERFORD STRUCTURAL OPTION FACULTY ADVISOR DR. THOMAS BOOTHBY AE SENIOR THESIS APRIL 8, 2013 HOTEL N.E.U.S. BUILDING INFORMATION SITE Located in the Northeast United States

More information

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity System Codes and Criteria Design Codes and Standards The design code used is the Wisconsin Administrative Code along with the State of Wisconsin Department of Commerce-Safety & Buildings Chapters Comm

More information

ALUMINUM STOP LOGS MODEL GENERAL DESCRIPTION

ALUMINUM STOP LOGS MODEL GENERAL DESCRIPTION GENERAL DESCRIPTION The Orbinox model Aluminum Stop Log is designed for open channel installations for temporary isolation and flow control. Stop Logs are ideal for maintenance and repair works or flood

More information

ANSI/ ASME HST Performance Standard For Overhead Electric Wire Rope Hoists

ANSI/ ASME HST Performance Standard For Overhead Electric Wire Rope Hoists SECTION 412213- BRIDGE CRANES Part 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

HANDSET WALL FORM. Handset Wall Form. Quick Assembly - can be built using only a hammer. Reduced weight increases productivity

HANDSET WALL FORM. Handset Wall Form. Quick Assembly - can be built using only a hammer. Reduced weight increases productivity HANDSET WALL FORM Quick Assembly - can be built using only a hammer Reduced weight increases productivity Unsurpassed flexibility in design and availability of panels for a wide variety of applications

More information

SMART FIXING SYSTEMS

SMART FIXING SYSTEMS SMART FIXING SYSTEMS REAR-VENTILATED FACADE The hung, rear-ventilated facade (RVF) covers the load bearing wall of a building. With a RVF, the facade elements are mounted with the help of a fixing system

More information

standard features Power Exhaust Fans w/light - Both Baths GFCI Receptacles Upgrade Light Fixture - Bath 1 Vanity - Per Lav GFCI Receptacles

standard features Power Exhaust Fans w/light - Both Baths GFCI Receptacles Upgrade Light Fixture - Bath 1 Vanity - Per Lav GFCI Receptacles 2017 standard features INTERIOR Cornice w / Full Length Drapes Panels-Main Living Areas only Shaw Moxie Carpet with Pad and Tack Designer Select Congoleum No Wax Vinyl Flooring 8 Flat Ceilings Throughout

More information

RB WEIR GATES MODEL GENERAL DESCRIPTION DESIGN CONSTRUCTION

RB WEIR GATES MODEL GENERAL DESCRIPTION DESIGN CONSTRUCTION GENERAL DESCRIPTION The Orbinox model RB Weir Gate is designed for downward opening applications where a more accurate flow control is required. The water flows over the top of the slide permitting a constant

More information

Telecommunication Spaces

Telecommunication Spaces Telecommunication Spaces October 19, 2016 Page 1 Revision History Telecommunication Spaces Standard Effective Date Email Version Contact Phone OIT-TS strevena@csustan.edu 1.0 Stan Trevena 209.667.3137

More information

Shown with optional high capacity air conditioning system and exterior quartz lights. New style exterior mounted quartz lights.

Shown with optional high capacity air conditioning system and exterior quartz lights. New style exterior mounted quartz lights. Custom designed cabinetry at the forward end of the car tread plates. The photo at the left shows the end cabinets in the stored position while the right photo features the cabinets in the raised position

More information

LIFE SCIENCES BUILDING STRUCTURAL CONCEPTS AND EXISTING CONDITIONS

LIFE SCIENCES BUILDING STRUCTURAL CONCEPTS AND EXISTING CONDITIONS Structural Technical Report 1 LIFE SCIENCES BUILDING STRUCTURAL CONCEPTS AND EXISTING CONDITIONS Prepared for: Dr. Aly M. Said Dr. Thomas Boothby Professor Kevin Parfitt Dr. Charles D. Cox Prepared by:

More information