2 Systems Guide For decades USG exterior ceiling systems have been utilized in a wide variety of exterior applications. USG exterior ceiling systems satisfy stringent performance requirements and design criteria while providing beauty and durability. Page Introduction 2 Systems Overview Exterior Ceiling Applications 5 Paraline Linear Metal Ceiling System Paraline Plus Linear Metal Ceiling Systems 17 Celebration Metal Panel Ceiling System 25 ZXLA with Sheetrock Lay-In Ceiling Panel ClimaPlus 31 USG Drywall Suspension System Other Considerations 42 Accessories Seismic Perimeter Applications For More Information Technical Service 800 USG.4YOU Web Site usg.com

3 Systems Overview USG Exterior Ceiling Applications USG provides five exterior systems for use in exterior environments that are not directly exposed to the weather such as under a soffit, parking garages, covered entrance or drivethrough. They include the: Paraline II Linear Metal Ceiling System 1 Paraline Plus Linear Metal Ceiling System Celebration Metal Panel Ceiling System ZXLA with Sheetrock Lay-In Ceiling Panel ClimaPlus USG Drywall Suspension System These ceiling systems combine traditional modules, elegant linear pans, or metal panels combined with a specially engineered suspension system to create dynamic ceilings with clean, contemporary planes. These guidelines outline the design considerations, test results and construction details for the installation of each USG exterior ceiling system. USG exterior assemblies were tested per: UL 580, UL 1897, TAS 202 and TAS 203, and listed in PEI Evaluation Report, PER For more information about UL Standards please visit For more information about Florida Building Code Testing Application Standards (TAS) please visit Celebration 1 Paraline II closed-reveal linear metal ceiling is the Paraline system appropriate for exterior ceiling applications. 2 USG Exterior Ceiling Applications

4 Systems Overview Performance Selector Paraline II Linear Metal Ceiling System Paraline Plus Linear Metal Ceiling System Main Tee / Carrier System Symmetrical Carrier Spacing Uplift Class Test Standard Maximum Load Rating¹ Main Tee Cross Tee Compression (w) Post Equivalent Wind Speed² (v) 48 in N/A 24 in N/A UL psf 134 mph 24 in N/A 24 in Class 90 UL psf 188 mph Paralock Carrier 48 in 24 in 24 in Class 30 UL psf 108 mph 48 in 24 in 24 in N/A UL psf 147 mph 24 in 24 in 30 in Class 60 UL psf 153 mph 24 in 24 in 24 in Class 90 UL psf 188 mph 24 in 24 in 24 in N/A UL psf 200 mph Fineline DXFEV with Celebration Metal Ceiling Panels ZXLA with Sheetrock Lay-in Ceiling Panel ClimaPlus USG Drywall Suspension System DXFEVH in 24 in 24 in Class 30 UL psf 108 mph 24 in 48 in 48 in Class 30³ Engineering 30 psf 108 mph Analysis 24 in 24 in 24 in Class 90 UL psf 188 mph 24 in 24 in 24 in N/A UL psf 200 mph DXFEVH in 30 in 30 in N/A UL psf 163 mph 30 in 30 in 30 in Class 60 UL psf 153 mph ZXLA26 48 in 24 in 24 in N/A UL psf 101 mph 24 in 48 in 24 in Class 30 UL psf 108 mph 24 in 48 in 24 in N/A UL psf 182 mph 48 in 24 in 24 in N/A UL psf 91 mph DGLW26 48 in 24 in 24 in Class 15 UL psf 77 mph 48 in 16 in 30 in Class 15 UL psf 77 mph 48 in 24 in 30 in Class 15 UL psf 77 mph 24 in 24 in 30 in Class 30 UL psf 108 mph 24 in 24 in 42 in Class 60 UL psf 108 mph 24 in 24 in 30 in Class 90 UL psf 188 mph 24 in 16 in 24 in Class 90 UL psf 188 mph 24 in 16 in 24 in N/A Miami Dade TAS202& psf 171 mph ¹ Ultimate loads per UL 1897 are 15% greater than the values presented. The values presented for UL 1897 have a 0.85 coefficient applied to account for possible installation deficiencies. 2 Calculated using simplified formula on page four. 3 Value derived through engineering calculation 3 USG Exterior Ceiling Applications

5 System Overview USG Exterior Ceiling Applications Wind Design Notes Miles per hour (MPH) versus pounds per square foot (PSF) ASCE 7-10, Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers/ Structural Engineering Institute (ASCE/SEI), contains a formula that converts wind speed into static pressure. The formula is a comprehensive approach to include factors such as height or location of the building, or directionality of wind loads affecting the structure expressed as: q z = K z K z t K d V 2 q z = velocity pressure evaluated at height z above the ground K z = velocity pressure exposure coefficient K z t = topographic factor K d = wind directionality factor V = basic wind speed The approximate value of wind pressure (PSF) can be calculated without knowing all of the factors described above by utilizing the simplified formula shown below. p = V 2 p is the pressure (measured in psf) V is the wind speed (measured in mph) Wind load provisions of ASCE 7-10, are recognized in the 2012 International Residential Code (IRC) and the 2012 International Building Code (IBC). The information presented is correct to the best of our knowledge at the date of issuance. Because codes continue to evolve, check with a local official prior to designing and installing a ceiling system. Other restrictions and exemptions may apply. Note: All systems shall comply with local wind load requirements. The engineer of record shall determine the final recommendation for the design wind pressure 4 USG Exterior Ceiling Applications

6 Linear Metal Ceiling Systems Paraline II Paraline Plus Technical Data Spacing Uplift Class Test Standard Maximum Load Rating Main Tee Cross Tee Compression (w) Post Equivalent Wind Speed (v) Paraline II Page 9 48 in N/A 24 in N/A UL psf 134 mph Page in N/A 24 in Class 90 UL psf 188 mph Paraline Plus Page in 24 in 24 in Class 30 UL psf 108 mph 48 in 24 in 24 in N/A UL psf 147 mph Page in 24 in 30 in Class 60 UL psf 153 mph Page in 24 in 24 in Class 90 UL psf 188 mph 24 in 24 in 24 in N/A UL psf 200 mph 5 USG Exterior Ceiling Applications

7 Paraline II and Paraline Plus Wind Resistance Paraline ceiling systems may be used for sheltered exterior applications not directly exposed to the weather. The Paraline II and Paraline Plus systems have been tested for wind load resistance. The two units of measure commonly used are miles per hour (mph) and pounds per square foot (psf), equated by the methods in ASCE 7, Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers/ Structural Engineering Institute (ASCE/SEI). 1 Limitations: Finish is not UV-resistant; Paraline should not be installed where direct exposure to sun or weather will occur, such as fascias or facades. Not suitable for areas subject to high concentrations of acid rain. Indirect exposure to severe environmental conditions may shorten the lifespan of the product. The specific design of exterior ceiling installations requires the review and approval of the architect or engineer of record. Please refer to IC463 for more information about Paraline ceiling systems. Technical Data Guidelines Panel Size Wind pressure presented in accordance with applicable test standards. Compression posts used for the tests were 3/49 EMT conduit with adapters. Building structure from which the Paraline system is suspended and spaced, as well as hanger wire and attachment methods, must be capable of withstanding the loads applied during wind conditions. Compression post shall be positively attached to the structure. For further information on the USG Donn Brand Compression Post, see pages Other materials can be used for s, provided the compressive strength and attachment method are approved for use by a local structural engineer. Architect s details must cover design and location of expansion joints in addition to meeting all applicable building code requirements. The Paraline and Paraline Plus systems presented in this guide can accommodate all available panel sizes. The performance values are not limited to a particular panel size. All available panel sizes will meet the performance values presented. ¹ System is to comply with local wind load requirements. The engineer of record shall determine the final recommendation for the design wind pressure requirements of each project. For more information about Paraline Linear Metal Ceiling System, visit 6 USG Exterior Ceiling Applications

8 Paraline II Application Details Layout 48" 48" hanger wires PARALINE pan splice staggered symmetrical carrier compression post adapter and EMT (4' o.c.) carrier splice hanger reinforcement clip 48" PARALINE pan max. 12" from wall trim channel finished wall or soffit Symmetrical Carrier Run structure spring clip compression post std. 3 /4" dia. EMT conduit hanger reinforcement clip top clip (mechanically fastened) compression post adapter spring clip hanger reinforcement clip top clip (mechanically fastened) symmetrical carrier Adjustable Post Detail 12 ga. hanger wire compression post adapter maximum 48" o.c. s and hanger wires hanger reinforcement clip symmetrical carrier 7 USG Exterior Ceiling Applications

9 Paraline II Application Details Pans Perpendicular to Wall Pans Parallel to Wall Wall Intersection ( 3 /4" EMT conduit with compression post adapter) hanger reinforcement clip 12" maximum symmetrical carrier ( 3 /4" EMT conduit with compression post adapter) 12 ga. hanger wire 12" maximum symmetrical carrier PARALINE II pan U-2-3/32 perimeter molding and hold-down clip PARALINE II pan hanger reinforcement clip U-2-3/32 perimeter molding and hold-down clip Note: Pop rivets shall be suitable for exterior use. 8 USG Exterior Ceiling Applications

10 Paraline II UL psf Main Tees: 48 in. o.c. Compression Posts: 24 in. o.c. Hanger & Compression Post Paraline Symmetrical Carrier 24" o.c. 12" max. 12" max. 48" o.c. Paraline II Assembly 12 ga. hanger wire ( 3 /4" EMT conduit with end plug) 12 ga. hanger wire ( 3 /4" EMT conduit with adapter) U-2-3/32 perimeter molding hanger reinforcement clip symmetrical carrier PARALINE II pan symmetrical carrier PARALINE II pan 9 USG Exterior Ceiling Applications

11 Paraline II UL 580 Class 90 Main Tees: 24 in. o.c. Compression Posts: 24 in. o.c. Hanger & Compression Post Paraline Symmetrical Carrier 24" o.c. 12" max. 12" max. 24" o.c. Paraline II Assembly 12 ga. hanger wire ( 3 /4" EMT conduit with end plug) 12 ga. hanger wire ( 3 /4" EMT conduit with adapter) U-2-3/32 perimeter molding hanger reinforcement clip symmetrical carrier PARALINE II pan symmetrical carrier PARALINE II pan 10 USG Exterior Ceiling Applications

12 Paraline Plus Application Details Layout 48" 48" PARALINE PLUS pan splice staggered PARALOCK main tee hanger wires 48" PARALINE PLUS pan max. 12" from wall trim channel finished wall or soffit Paralock Carrier Run structure spring clip ( 3 /4" EMT conduit with end plug) top clip (mechanically fastened) spring clip top clip (mechanically fastened) PARALOCK main tee PARALOCK main tee Post Detail 12 ga. hanger wire ( 3 /4" EMT conduit with end plug) maximum 48" o.c. s and hanger wires 12 ga. hanger wire ( 3 /4" EMT conduit with end plug) PARALOCK Main tee 11 USG Exterior Ceiling Applications

13 Paraline Plus Application Details Pans Perpendicular to Wall Pans Parallel to Wall Wall Intersection ( 3 /4" EMT conduit with end plug) cross tee 12" maximum MAC2 clip ( 3 /4" EMT conduit with end plug) 12 ga. hanger wire 12" maximum MAC2 clip PARALOCK main tee PARALOCK main tee snap-loc insert PARALINE PLUS pan U-2-3/32 perimeter molding and hold-down clip snap-loc insert PARALINE PLUS pan U-2-3/32 perimeter molding and hold-down clip Notes: Pop rivets shall be suitable for exterior use. Field notch top flange of molding at grid intersection. 12 USG Exterior Ceiling Applications

14 Paraline Plus UL 580 Class 30 Main Tees: 48 in. o.c. Compression Posts: 24 in. o.c. Cross Tees: 24 in. o.c. Hanger & Compression Post Paralock Carrier ZXLA424 (48 in. Cross Tee) 24" o.c. 12" max. 12" max. 48" o.c. Paraline Plus Assembly ( 3 /4" EMT conduit) 12 ga. hanger wire ( 3 /4" EMT conduit) 12 ga. hanger wire PARALOCK main tee snap-loc insert PARALINE II pan ZXLA 4ft. cross tee PARALOCK main tee PARALINE PLUS pan snap-loc insert 13 USG Exterior Ceiling Applications

15 Paraline Plus UL 580 Class 60 Main Tees: 24 in. o.c. Compression Posts: 30 in. o.c. Cross Tees: 24 in. o.c. Hanger & Compression Post Paralock Carrier ZXLA224 (24 in. Cross Tee) 24" o.c. 30" o.c. 12" max. 12" max. 24" o.c. Paraline Plus Assembly 12 ga. hanger wire ( 3 /4" EMT conduit) 12 ga. hanger wire ( 3 /4" EMT conduit) PARALOCK main tee snap-loc insert PARALINE II pan ZXLA 2ft. cross tee PARALINE PLUS pan snap-loc insert PARALOCK main tee 14 USG Exterior Ceiling Applications

16 Paraline Plus UL 580, UL psf, 102 psf Main Tees: 24 in. o.c. Compression Posts: 24 in. o.c. Cross Tees: 24 in. o.c. Hanger & Compression Post Paralock Carrier ZXLA224 (24 in. Cross Tee) 24" o.c. 12" max. 12" max. 24" o.c. Paraline Plus Assembly 12 ga. hanger wire ( 3 /4" EMT conduit) 12 ga. hanger wire ( 3 /4" EMT conduit) PARALOCK main tee snap-loc insert PARALINE II pan ZXLA 2ft. cross tee PARALINE PLUS pan snap-loc insert PARALOCK main tee 15 USG Exterior Ceiling Applications

17

18 Celebration Metal Ceiling Panels Fineline DXFEV Technical Data Spacing Uplift Class Test Standard Maximum Load Rating Main Tee Cross Tee Compression Post (w) Equivalent Wind Speed (v) DXFEVH 2924 Page in 24 in 24 in Class 30 UL psf 108 mph Page in 48 in 48 in Class 30¹ Engineering Analysis 30 psf 108 mph Page in 24 in 24 in Class 90 UL psf 188 mph 24 in 24 in 24 in N/A UL psf 200 mph DXFEVH 2930 Page in 30 in 30 in N/A UL psf 163 mph 30 in 30 in 30 in Class 60 UL psf 153 mph 1 Value derived through engineering calculation 17 USG Exterior Ceiling Applications

19 Celebration Wind Resistance Celebration ceiling systems may be used for sheltered exterior applications not directly exposed to the weather. Celebration systems have been tested for wind load resistance. The two units of measure commonly used are miles per hour (mph) and pounds per square foot (psf), equated by methods in ASCE 7, Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers/Structural Engineering Institute (ASCE/SEI).¹. Limitations: Finish is not UV-resistant; Celebration should not be installed where direct exposure to sun or weather will occur, such as fascias or facades. Not suitable for areas subject to high concentrations of acid rain. Indirect exposure to severe environmental conditions may shorten the lifespan of the product. The specific design of exterior ceiling installations requires the review and approval of the architect or engineer of record. Please refer to IC415 for more information about Celebration ceiling systems. Technical Data Guidelines Panel Size Wind pressure presented in accordance with applicable test standards. Compression posts used for the tests were 3/49 EMT conduit. Building structure from which the Celebration system is suspended and spaced, as well as hanger wire and compression post attachment methods, must be capable of withstanding the loads applied during wind conditions. Compression post shall be positively attached to the structure. For further information on the USG Donn Brand Compression Post, see pages Heavy duty main tees shall be used. Other materials can be used for s, provided the compressive strength and attachment method are approved for use by a local structural engineer. Architect s details must cover design and location of expansion joints in addition to meeting all applicable building code requirements. The Celebration systems presented in this guide can accommodate all available panel sizes. The performance values are not limited to a particular panel size. All available panel sizes will meet the performance values presented. ¹ System is to comply with local wind load requirements. The engineer of record shall determine the final recommendation for the design wind pressure requirements of each project. For more information about Celebration Metal Panel Ceiling Systems, visit 18 USG Exterior Ceiling Applications

20 Celebration Wind Resistance Perimeter Molding U-2-3/ /8" 2 3 /32" 7 /8" Accessories U-2-3/32 Hold Down Clip 3 /4" 2 3 /32" 11 /32" CA1 Arrowhead Reveal Spacer 1 /4" 1 /4" 19 USG Exterior Ceiling Applications

21 Celebration UL 580 Class 30 Main Tees: 48 in. o.c. Cross Tees: 24 in. o.c. Compression Posts: 24 in. o.c. Hanger & Compression Post DXFEVH2924 (Heavy Duty Main Tee) DXFEV429N (48 in. Cross Tee) DXFEV229 (24 in. Cross Tee) Note: Celebration panels cannot be installed across a main tee and a 4ft. cross tee. 24" o.c. 12" max. 12" max. 48" o.c. Perimeter Conditions 12" max. 12 ga. hanger wire DXFEVH FINELINE main tee arrowhead spacer for cut perimeter panels into first reveal row Celebration perimeter panel U-2-3/32 molding U-2-3/32 hold down clip min. 2 per perimeter panel Note: U-2-3/32 molding is designed to receive the perimeter tees and the tee ends are not cut back at an angle. Back blocking is not required. Fastener attachment through the top leg of molding inth the tee bulb is required. Item Number Hold-Down Clip U-2-3/32HDC Channel Molding U-2-3/ Commodity Code 20 USG Exterior Ceiling Applications

22 Celebration UL 580 Class 30 Main Tees: 24 in. o.c. Cross Tees: 48 in. o.c. Compression Posts: 48 in. o.c. Hanger & Compression Post DXFEVH2924 (Heavy Duty Main Tee) DXFEV229 (24 in. Cross Tee) Note: Celebration panels cannot be installed across a main tee. 48" o.c. 12" max. 12" max. 24" o.c. Perimeter Conditions 12" max. 12 ga. hanger wire DXFEVH FINELINE main tee arrowhead spacer for cut perimeter panels into first reveal row Celebration perimeter panel U-2-3/32 molding U-2-3/32 hold down clip min. 2 per perimeter panel Note: U-2-3/32 molding is designed to receive the perimeter tees and the tee ends are not cut back at an angle. Back blocking is not required. Fastener attachment through the top leg of molding inth the tee bulb is required. Item Number Hold-Down Clip U-2-3/32HDC Channel Molding U-2-3/ Commodity Code 21 USG Exterior Ceiling Applications

23 Celebration UL 580 Class 90 Main Tees: 24 in. o.c. Cross Tees: 24 in. o.c. Compression Posts: 24 in. o.c. Hanger & Compression Post DXFEVH2924 (Heavy Duty Main Tee) DXFEV229 (24 in. Cross Tee) Note: Celebration panels cannot be installed across a main tee. 24" o.c. 12" max. 12" max. 24" o.c. Perimeter Conditions 12" max. 12 ga. hanger wire DXFEVH FINELINE main tee arrowhead spacer for cut perimeter panels into first reveal row Celebration perimeter panel U-2-3/32 molding U-2-3/32 hold down clip min. 2 per perimeter panel Note: U-2-3/32 molding is designed to receive the perimeter tees and the tee ends are not cut back at an angle. Back blocking is not required. Fastener attachment through the top leg of molding inth the tee bulb is required. Item Number Hold-Down Clip U-2-3/32HDC Channel Molding U-2-3/ Commodity Code 22 USG Exterior Ceiling Applications

24 Celebration UL 580 Class 60 Main Tees: 30 in. o.c. Cross Tees: 30 in. o.c. Compression Posts: 30 in. o.c. Hanger Wire & Compression Post DXFEVH2930 (Heavy Duty Main Tee) DXFEV30 (30 in. Cross Tee) 1 1 Special Order Note: Celebration panels cannot be installed across a main tee. 30" o.c. 15" max. 15" max. 30" o.c. Perimeter Conditions 12" max. 12 ga. hanger wire DXFEVH FINELINE main tee arrowhead spacer for cut perimeter panels into first reveal row Celebration perimeter panel U-2-3/32 molding U-2-3/32 hold down clip min. 2 per perimeter panel Note: U-2-3/32 molding is designed to receive the perimeter tees and the tee ends are not cut back at an angle. Back blocking is not required. Fastener attachment through the top leg of molding inth the tee bulb is required. Item Number Hold-Down Clip U-2-3/32HDC Channel Molding U-2-3/ Commodity Code 23 USG Exterior Ceiling Applications

25

26 Sheetrock Lay-In Ceiling Panel ClimaPlus ZXLA Technical Data Spacing Uplift Class Test Standard Maximum Load Rating Main Tee Cross Tee Compression Post (w) Equivalent Wind Speed (v) ZXLA26 Page in 24 in 24 in N/A UL psf 101 mph Page in 48 in 24 in Class 30 UL psf 108 mph 24 in 48 in 24 in N/A UL psf 182 mph Page in 24 in 24 in N/A UL psf 91 mph 25 USG Exterior Ceiling Applications

27 ZXLA with Sheetrock Lay-In Ceiling Panel ClimaPlus Wind Resistance ZXLA Suspension Systems with Sheetrock Lay-In Ceiling Panel ClimaPlus may be used for sheltered exterior applications not directly exposed to the weather. These systems have been tested for wind load resistance. The two units of measure commonly used are miles per hour (mph) and pounds per square foot (psf), equated by methods in ASCE 7, Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers/Structural Engineering Institute (ASCE/SEI).¹ Limitations: Should not be installed where direct exposure to sun or weather will occur, such as fascias or facades. Not suitable for areas subject to high concentrations of acid rain. Indirect exposure to severe environmental conditions may shorten the lifespan of the product. The specific design of exterior ceiling installations requires the review and approval of the architect or engineer of record. Technical Data Wind pressure arrived in accordance with applicable test standards. Compression posts used for the tests were 3/49 EMT conduit. Available Panels Edge Panel Size Item No. Sheetrock Lay-In Ceiling Panel ClimaPlus, Vinyl Square 28 x 28 x 1/ Square 28 x 48 x 1/ Guidelines Building structure from which the Sheetrock Lay-In Ceiling Panel system is suspended and spaced, as well as hanger wire and attachment methods, must be capable of withstanding the loads applied during wind conditions. Other materials can be used for s, provided the compressive strength and attachment method are approved for use by a local structural engineer. Min. 6d common hold down nails or similar device shall be installed at regular intervals to prevent uplift. Min. 6 for each 28 x 48 panel module and min. 4 for each 28 x 28 panel module. Min. 6d common hold down nails or similar device shall be inserted in alternating directions. Min. 6d common hold down nails or similar device may be installed through the hanger wire holes, cross tee clip holes and through a field-punched hole in the web of the tee. Architect s details must cover design and location of expansion joints in addition to meeting all applicable building code requirements. 1 System is to comply with local wind load requirements. The engineer of record shall determine the final recommendation for the design wind pressure requirements of each project. 26 USG Exterior Ceiling Applications

28 ZXLA with Sheetrock Lay-In Ceiling Panel ClimaPlus 28 x 48 System UL psf Main Tees: 48 in. o.c. Cross Tees: 24 in. o.c. Compression Posts: 24 in. o.c. Hanger & Compression Post ZXLA26 (Heavy Duty Main Tee) ZXLA424 (48 in. Cross Tee) Hold-Down Nail 24" o.c. 12" max. 12" max. 48" o.c. Perimeter Conditions 12" max. 12 ga. hanger wire hold-down nail to prevent panel uplift (see accompanying section detail) screw attached wall molding ZXLA main tee Sheetrock Lay-In Ceiling Panel ClimaPlus M7Z molding pop rivet or MAC2 molding attachment clip Hold-Down Nail tee min. 6d common hold-down nails or similar device shall inserted in alternating directions Note: Pop rivets shall be suitable for exterior use. Sheetrock Lay-In Ceiling Panel ClimaPlus 27 USG Exterior Ceiling Applications

29 ZXLA with Sheetrock Lay-In Ceiling Panel ClimaPlus 28 x 48 System UL 580 Class 30 Main Tees: 24in. o.c. Cross Tees: 48 in. o.c. Compression Posts: 24 in. o.c. Hanger & Compression Post ZXLA26 (Heavy Duty Main Tee) ZXLA224 (24 in. Cross Tee) Hold-Down Nail 24" o.c. 12" max. 12" max. 24" o.c. Perimeter Conditions 12" max. 12 ga. hanger wire hold-down nail to prevent panel uplift (see accompanying section detail) screw attached wall molding ZXLA main tee Sheetrock Lay-In Ceiling Panel ClimaPlus M7Z molding pop rivet or MAC2 molding attachment clip Hold-Down Nail tee min. 6d common hold-down nails or similar device shall inserted in alternating directions Note: Pop rivets shall be suitable for exterior use. Sheetrock Lay-In Ceiling Panel ClimaPlus 28 USG Exterior Ceiling Applications

30 ZXLA with Sheetrock Lay-In Ceiling Panel ClimaPlus 28 x 28 System UL psf Main Tees: 48 in. o.c. Cross Tees: 24 in. o.c. Compression Posts: 24 in. o.c. Hanger & Compression Post ZXLA26 (Heavy Duty Main Tee) ZXLA424 (48 in. Cross Tee) ZXLA224 (24 in. Cross Tee) Hold-Down Nail 24" o.c. 12" max. 12" max. 48" o.c. Perimeter Conditions 12" max. 12 ga. hanger wire hold-down nail to prevent panel uplift (see accompanying section detail) screw attached wall molding ZXLA main tee Sheetrock Lay-In Ceiling Panel ClimaPlus M7Z molding pop rivet or MAC2 molding attachment clip Hold-Down Nail tee min. 6d common hold-down nails or similar device shall inserted in alternating directions Note: Pop rivets shall be suitable for exterior use. Sheetrock Lay-In Ceiling Panel ClimaPlus 29 USG Exterior Ceiling Applications

31 ZXLA with Sheetrock Lay-In Ceiling Panel ClimaPlus 28 x 48 System UL psf Main Tees: 24 in. o.c. Cross Tees: 48 in. o.c. Compression Posts: 24 in. o.c. Hanger & Compression Post ZXLA26 (Heavy Duty Main Tee) ZXLA224 (24 in. Cross Tee) Hold-Down Nail 48" o.c. 12" max. 12" max. 24" o.c. Perimeter Conditions 12" max. 12 ga. hanger wire hold-down nail to prevent panel uplift (see accompanying section detail) screw attached wall molding ZXLA main tee Sheetrock Lay-In Ceiling Panel ClimaPlus M7Z molding pop rivet or MAC2 molding attachment clip Hold-Down Nail tee min. 6d common hold-down nails or similar device shall inserted in alternating directions Note: Pop rivets shall be suitable for exterior use. Sheetrock Lay-In Ceiling Panel ClimaPlus 30 USG Exterior Ceiling Applications

32 USG Drywall Suspension System DGLW26 Technical Data Spacing Uplift Class Test Standard Main Tee Cross Tee Compression Post Test Record Maximum Load Rating (w) Equivalent Wind Speed (v) DGLW26 Page in 24 in 24 in Class 15 UL580 UL psf 77 mph Page in 16 in 30 in Class 15 UL580 UL526A 15 psf 77 mph 48 in 24 in 30 in Class 15 UL580 UL526B 15 psf 77 mph Page in 24 in 30 in Class 30 UL580 UL526C 30 psf 108 mph Page in 24 in 42 in Class 60 UL580 UL526D 30 psf 108 mph Page in 24 in 30 in Class 90 UL580 UL526E 90 psf 188 mph Page in 16 in 24 in Class 90 UL580 UL526F 90 psf 188 mph Page in 16 in 24 in N/A Miami Dade TAS202&203 NOA psf 171 mph 31 USG Exterior Ceiling Applications

33 USG Drywall Suspension System Wind Uplift Resistance for Exterior Soffits USG has a selection of Drywall Suspension assemblies to accommodate the wind loads for most applications. The system has been tested using applicable industry standards for wind uplift resistance when installed in exterior soffits and canopies. For more information regarding test standards and online resources, please refer to the Systems Overview section of this catalogue. Only Sheetrock brand exterior ceiling board, Durock cement board and Securock Glass Mat Sheathing are suitable for exterior applications. Specific information for gypsum panel applications can be found at usg.con and usgdesignstudio.com. The following pages detail the components and their spacing which are necessary to achieve the different uplift classifications, including spacing, limiting plenum depths, and construction details for the installation. The structure that the USG Drywall Suspension System is attached to shall be designed to withstand the applicable wind loads and carry the soffit system total weight. Note: Design wind loads vary with geographic region and building conditions, and must be determined by a professional engineer or architect of record. 32 USG Exterior Ceiling Applications

34 USG Drywall Suspension System Wind Uplift Resistance for Exterior Soffitts C D compression post hanger wire main tee cross tee A B Test Record UL526 page 36 UL Class Max Uplift Load (PSF) Equivalent Wind Speed, (MPH) Component Spacing Max Spacing (in.) (A) Main Runner (B) Cross Tee (C) 12 Gauge Hanger Wire (D) Compression Post Exterior soffit Panels Single layer 5/89 gypsum panels Plenum Height¹ (in) Max compression post load (lbs) Test Standard UL 580 UL526A, B page (526A) 24 (526B) single layer 1/29 gypsum panels UL 580 UL526C page 38 UL526D page 39 UL526E page 40 UL526F page single layer 1/29 gypsum panels double layer 5/89 gypsum panels double layer 5/89 gypsum panels Single layer 5/89 gypsum panels, single layer 3/89 plywood UL UL UL UL 580 NOA No page 42 N/A +75, single layer 1/29 or 5/89 glass mat sheathing w/ direct applied EFIS TAS 202, TAS Larger plenum heights require size and gauge to be determined by a quaified structural engineer. 33 USG Exterior Ceiling Applications

35 USG Drywall Suspension System Test Record UL526 Class 15 Uplift System Components Main runners Cross Tees Perimeter Molding Gypsum Panels DGL26 or DGLW26 DGL424 or DGLW424 DGWM24 angle mold or DGCM27 channel mold. When angle mold is used, main runners and cross tees attached to molding with 1/29 type S screws. 5/8 in. thick, 4 ft wide, installed with long dimension perpendicular to cross tees. End joints centered along cross tees, side joints to be centered along main runners. Gypsum board fastened to each cross tee with No. 8 by 1 in. long bugle head screws with one screw located at midspan of cross tee and with additional screws located 12 in. o.c. beginning from center screw and with screws located 1-1/2 in. from each gypsum board side joint. At gypsum board butt ends, a total of seven screws used, with one screw located at midspan of cross tee and additional screws spaced 8 in. o.c. with one screw located 1-1/2 in. from wall board side joint. All screws located max 1/2 in. from edge. End joints of adjacent sheets staggered min. 4 ft. Sheets fastened to lower leg of wall channel with screws spaced max 12 in. o.c. Type Max Unbraced Length (in) Compression Posts 3/49 x 1/29 x channel 31 3/49 x 1/29 x channel (Back-to-back) /29 x 7/329 x channel /29 x 7/329 x channel (Back-to-back) 41 3/49 EMT conduit, wall thickness /89 25 gauge steel studs, min /89 25 gauge steel studs, min (Back-to-back) 141 Back to back types shall be connected with stitch welds at 129 OC or with 1/49 dia bolts at 129 OC, first connection within 69 of each end. Compression posts to be located within 69 of expansion joints if applicable. All notched at ends to fit over bulb of main runner. Compression post fastened to main runners with type S coated steel screw or equivalent 33 ksi min steel. 34 USG Exterior Ceiling Applications

36 USG Drywall Suspension System Test Record UL526A, B Class 15 Uplift System Components Main runners Cross Tees Perimeter Molding Gypsum Panels DGL26 or DGLW26 DGL424 or DGLW424, or DGCL4 hat shaped cross channels (record UL526B) DGWM24 angle mold or DGCM27 channel mold. When angle mold is used, main runners and cross tees attached to molding with 1/2 type S screws. 1/2 in. thick, 4 ft wide, installed with long dimension perpendicular to cross tees. End joints centered along cross tees, side joints to be centered along main runners. Gypsum board fastened to each cross tee with No. 8 by 1 in. long bugle head screws with one screw located at midspan of cross tee and with additional screws located 12 in. o.c. beginning from center screw and with screws located 1-1/2 in. from each gypsum board side joint. At gypsum board butt ends, a total of seven screws used, with one screw located at midspan of cross tee and additional screws spaced 8 in. o.c. with one screw located 1-1/2 in. from wall board side joint. All screws located max 1/2 in. from edge. End joints of adjacent sheets staggered min. 4 ft. Sheets fastened to lower leg of wall channel with screws spaced max 12 in. o.c. Type Max Unbraced Length (in) Compression Posts 3/49 x 1/29 x channel 31 3/49 x 1/29 x channel (Back-to-back) /29 x 7/329 x channel /29 x 7/329 x channel (Back-to-back) 41 3/49 EMT conduit, wall thickness /89 25 gauge steel studs, min /89 25 gauge steel studs, min (Back-to-back) 128 Back to back types shall be connected with stitch welds at 129 OC or with 1/49 dia bolts at 129 OC, first connection within 69 of each end. Compression posts to be located within 69 of expansion joints if applicable. All notched at ends to fit over bulb of main runner. Compression post fastened to main runners with type S coated steel screw or equivalent 33 ksi min steel. 35 USG Exterior Ceiling Applications

37 USG Drywall Suspension System Test Record UL526C Class 30 Uplift System Components Main runners Cross Tees Perimeter Molding Gypsum Panels DGL26 or DGLW26 DGL26 or DGLW26 DGWM24 angle mold or DGCM27 channel mold. When angle mold is used, main runners and cross tees attached to molding with 1/29 type S screws. 5/8 in. thick, 4 ft wide, installed with long dimension perpendicular to cross tees. End joints centered along c1/2 in. thick, 4 ft wide, installed with long dimension perpendicular to cross tees. End joints centered along cross tees, side joints to be centered along main runners. Gypsum board fastened to each cross tee with No. 8 by 1 in. long bugle head screws with one screw located at midspan of cross tee and with additional screws located 12 in. o.c. beginning from center screw and with screws located 1-1/2 in. from each gypsum board side joint. At gypsum board butt ends, a total of seven screws used, with one screw located at midspan of cross tee and additional screws spaced 8 in. o.c. with one screw located 1-1/2 in. from wall board side joint. All screws located max 1/2 in. from edge. End joints of adjacent sheets staggered min. 4 ft. Sheets fastened to lower leg of wall channel with screws spaced max 12 in. o.c. Type Max Unbraced Length (in) Compression Posts 3/49 x 1/29 x channel 31 3/49 x 1/29 x channel (Back-to-back) /29 x 7/329 x channel /29 x 7/329 x channel (Back-to-back) 41 3/49 EMT conduit, wall thickness /89 25 gauge steel studs, min /89 25 gauge steel studs, min (Back-to-back) 1130 Back to back types shall be connected with stitch welds at 129 OC or with 1/49 dia bolts at 129 OC, first connection within 69 of each end. All notched at ends to fit over bulb of main runner. Compression posts to be located within 69 of expansion joints if applicable. Compression post fastened to main runners with type S coated steel screw or equivalent. 33 ksi min steel. 36 USG Exterior Ceiling Applications

38 USG Drywall Suspension System Test Record UL526D Class 60 Uplift System Components Main runners Cross Tees Perimeter Molding Gypsum Panels DGL26 or DGLW26 DGL224 or DGLW224 DGWM24 angle mold or DGCM27 channel mold. When angle mold is used, main runners and cross tees attached to molding with 1/29 type S screws. Two layers of 5/8 in. thick, 4 ft wide gypsum board. Inner layer installed with long dimension perpendicular to cross tees. End joints centered along cross tees. Side joints centered along main runners. Gypsum board fastened to each cross tee with no. 8, 1 in. long bugle head screws with one screw located at midspan of cross tee and with additional screws spaced 12 in. o.c. beginning from center screw with screws located 1-1/2 in. from gypsum board side joint. At butt ends, a total of seven screws used with one screw located at midspan of cross tee and additional screws spaced 8 in. o.c. with one screw located 1-1/2 in. from side joints. All screws located 1/2 in. from edge. End joints of adjacent sheets staggered min 4ft. Outer layer rotated 90 degree from inner layer and attached to cross tees and main runners through inner layer using 1-5/8 in. long screws spaced 8 in. o.c. at butt ends. and 12 in. o.c. in the field. (Same spacing as inner layer). Butt joints centered along main runners and staggered min 4 ft. Gypsum board attached to lower leg of wall channel with fasteners spaced 12 in. o.c. for both layers. Type Max Unbraced Length (in) Compression Posts 3/49 x 1/29 x channel 28 3/49 x 1/29 x channel (Back-to-back) /29 x 7/329 x channel /29 x 7/329 x channel (Back-to-back) 41 3/49 EMT conduit, wall thickness /89 25 gauge steel studs, min /89 25 gauge steel studs, min (Back-to-back) 76 Back to back types shall be connected with stitch welds at 129 OC or with 1/49 dia bolts at 129 OC, first connection within 69 of each end. Compression posts to be located within 6 of expansion joints if applicable. All notched at ends to fit over bulb of main runner. Compression post fastened to main runners with type S coated steel screw or equivalent 33 ksi min steel. 37 USG Exterior Ceiling Applications

39 USG Drywall Suspension System Test Record UL526E Class 90 Uplift System Components Main runners Cross Tees Perimeter Molding Gypsum Panels DGL26 or DGLW26 DGL424 or DGLW424 DGWM24 angle mold or DGCM27 channel mold. When angle mold is used, main runners and cross tees attached to molding with 1/29 type S screws. Two layers of 5/8 in. thick, 4 ft wide gypsum board. Inner layer installed with long dimension perpendicular to cross tees. End joints centered along cross tees. Side joints centered along main runners. Gypsum board fastened to each cross tee with no. 8, 1 in. long bugle head screws with one screw located at midspan of cross tee and with additional screws spaced 12 in. o.c. beginning from center screw with screws located 1-1/2 in. from gypsum board side joint. At butt ends, a total of seven screws used with one screw located at midspan of cross tee and additional screws spaced 8 in. o.c. with one screw located 1-1/2 in. from side joints. All screws located 1/2 in. from edge. End joints of adjacent sheets staggered min 4ft. Outer layer rotated 90 degree from inner layer and attached to cross tees and main runners through inner layer using 1-5/8 in. long screws spaced 8 in. o.c. at butt ends. and 12 in. o.c. in the field. (Same spacing as inner layer). Butt joints centered along main runners and staggered min 4 ft. Gypsum board attached to lower leg of wall channel with fasteners spaced 12 in. o.c. for both layers. Type Max Unbraced Length (in) Compression Posts 3/49 x 1/29 x channel 28 3/49 x 1/29 x channel (Back-to-back) /29 x 7/329 x channel /29 x 7/329 x channel (Back-to-back) 41 3/49 EMT conduit, wall thickness /89 25 gauge steel studs, min /89 25 gauge steel studs, min (Back-to-back) 76 Back to back types shall be connected with stitch welds at 129 OC or with 1/49 dia bolts at 129 OC, first connection within 69 of each end. Compression posts to be located within 69 of expansion joints if applicable. All notched at ends to fit over bulb of main runner. Compression post fastened to main runners with type S coated steel screw or equivalent 33 ksi min steel. 38 USG Exterior Ceiling Applications

40 USG Drywall Suspension System Test Record UL526F Class 90 Uplift System Components Main Runners Cross Tees Perimeter Molding Plywood Gypsum Panels DGL26 or DGLW26 DGL224 or DGLW224 DGWM24 angle mold or DGCM27 channel mold. When angle mold is used, main runners and cross tees attached to molding with 1/29 type S screws. 4 ft wide by 8 ft long by nom 3/8 in. thick (11/32 in.), B-C Group 1 exterior grade. Installed with long dimension perpendicular to main runner and centered along cross tees with end joints centered along main runners. Plywood fastened to cross tees and main runners with 1-1/4 in. long steel screws spaced 8 in. o.c. End joints of adjacent plywood sheets staggered not less than 2 ft o.c. Plywood sheet screws attached to lower leg of wall channel with screws spaced 12 in. o.c. 5/8 in. thick, 4 ft wide, installed with long dimension parallel with main runners with end joints centered along cross tees and with side joints centered along main runners. Wallboard fastened to each cross tee and main runner through plywood with 1-5/8 in. long no. 8 bugle head steel screws spaced 8 in. o.c. One screw located at the midspan of the cross tee, with screws spaced 8 in. o.c. from each side of the cross tee midspan with screws located 1-1/2 in. from each gypsum board side joint. At butt ends joints of adjacent wallboard staggered 48 in. Gypsum board fastened to cross tees with 14 wallboard screws, seven per each end of wallboard. Wallboard sheets screw attached to lower leg of wall channel with wallboard screws spaced 12 in. o.c. Type Max Unbraced Length (in) Compression Posts 3/49 x 1/29 x channel 28 3/49 x 1/29 x channel (Back-to-back) /29 x 7/329 x channel /29 x 7/329 x channel (Back-to-back) 41 3/49 EMT conduit, wall thickness /89 25 gauge steel studs, min /89 25 gauge steel studs, min (Back-to-back) 76 Back to back types shall be connected with stitch welds at 129 OC or with 1/49 dia bolts at 129 OC, first connection within 69 of each end. Compression posts to be located within 6 of expansion joints if applicable. All notched at ends to fit over bulb of main runner. Compression post fastened to main runners with type S coated steel screw or equivalent 33 ksi min steel. 39 USG Exterior Ceiling Applications

41 USG Drywall Suspension System NOA No psf uplift, for High Velocity Hurricane Zones System Components Main Runners Main Runner Splice (in required) DGLW26 DGSC-180, attached to main runner on each side with two no. 8, S12 screws. Hanger wire and located within 69 of splice. Cross Tee DGLW 224 Perimeter Channel Molding DGCM2, fastened to structure with #8 screws (or equivalent) at 89 OC Compression Posts Sheathing panels Direct Applied Exterior Finish System (by others) Size and gauge to be determined by a qualified structural engineer depending on project conditions, such as plenum height and supporting structure type. One layer Securock Glass Mat sheathing panels, 1/29 or 5/89 thick, installed with long dimensions parallel with main runners, attached to main runners and cross tees with #8, 1-1/49 truss head screws spaced 89 OC, end joints staggered. Fiberglass reinforcing mesh imbedded with acrylic modified cementitious basecoat, acrylic finish. For complete installation details, see Miami-Dade County Notice of Acceptance no at miamidade.gov/economy. 40 USG Exterior Ceiling Applications

42 Other Considerations Accessories Seismic Perimeter Applications 41 USG Exterior Ceiling Applications

43 Accessories Compression Post The USG Donn Brand Compression Post provides rigid support for ceiling suspension systems in exterior applications. The telescoping s attach to the main tees and Paraline symmetrical carriers ¹ preventing upward movement of the system. Features Factory-engineered solution provides rigid support for ceiling suspension systems in exterior applications and offers quick installation thus reducing field labor time. Availabe in six different telescoping sizes that meet requirements and includes fast delivery. Item No. Size VSA 18/ to 309 VSA 30/ to 489 VSA 48/ to 849 VSA 84/ to 1029 VSA 102/ to 1209 VSA 120/ to 1449 Injection-molded, high-impact clip snaps onto the bulb of the main tee for a secure, positive connection. When used with Paraline systems, Paraline adapters¹ connect the post to the Paraline symmetrical carrier for a secure, positive connection. Heavy-wall galvanized steel tubing, no-rust telescoping post locks into permanent support length. Injection-molded guide ring prevents rattling. Spring steel top clip for attachment to vertical hanger wire adjacent to post The adjustable self-locking connection has been tested and certified to a minimum compressive load of 900 lb. Meets UL797 Components End Plug Top Clip Hanger Wire Spring Clip Attachment Spring Clip Holes (Top of Post) Note: The end plug, top clip and hanger wire spring clip are included with each post. ¹ When used with Paraline systems, Paraline adapters must be purchased. The end plug of the compression post is removed and replaced with the Paraline adapter prior to installation. The Paraline adapter is not included with each and must be purchased separately. 42 USG Exterior Ceiling Applications

44 Accessories Compression Post Application 1 Step 1 Fit top clip into the opening of the post. Step 2 Step 3 Step 4 Step 5 Step 6 Snap onto main tee bulb next to vertical hanger wire. Bring to vertical with hanger and extend post for snug fit against structure. Loop spring clip around vertical hanger wire and connect to holes on top of post. Mechanically fasten end plug of post to main tee bulb. Fasten to structure with the appropriate mechanical fastener. structure spring clip attachment holes hanger wire top clip top clip (mechanically fastened) spring clip bulb clip (mechanically fastened) ceiling ¹ When used with Paraline systems, Paraline adapters must be purchased. The end plug of the compression post is removed and replaced with the Paraline adapter prior to installation. The Paraline adapter is not included with each and must be purchased separately. 43 USG Exterior Ceiling Applications

45 Celebration Seismic Perimeter Applications Perimeter Conditions 1 Fixed 8" max. 12 ga. hanger wire DXFEV FINELINE main or cross tee ACM7 clip arrowhead spacer for cut perimeter panels into first reveal row Celebration perimeter panel fasten one through either top hole and one through the wing into the wall M7Z molding Floating 8" max. 12 ga. hanger wire DXFEV FINELINE main or cross tee ACM7 clip 3 /4" arrowhead spacer for cut perimeter panels into first reveal row Celebration perimeter panel fasten one through center of slot and one through the wing into the wall M7Z molding Note: 3/49 gap shown for typical seismic design categories D-F. 3/89 gap is typical for seismic design category C. ¹Other seismic detailing may be required. Please visit or for more information. 44 USG Exterior Ceiling Applications

46 ZXLA with Sheetrock Lay-In Ceiling Panel ClimaPlus Seismic Perimeter Applications Fixed Perimeter Treatment Options 1 ACM7 Seismic Clip 12 ga. hanger wire AX or ZXLA main or cross tee 8" max. attach ACM7 clip to wall through the top holes of the clip wings screw attach through either top hole into bulb Sheetrock Lay-In Ceiling Panel ClimaPlus hold-down nail to prevent panel uplift (see accompanying section detail) ACM7 clip M7A molding 29 Wall Molding 12 ga. hanger wire AX or ZXLA main or cross tee 8" max. blocking for perimeter ends of tees to prevent uplift stabilizer bar Sheetrock Lay-In Ceiling Panel ClimaPlus hold-down nail to prevent panel uplift (see accompanying section detail) M20A molding 1 Hold-Down Nail tee min. 6d common hold-down nails or similar device shall inserted in alternating directions Sheetrock Lay-In Ceiling Panel ClimaPlus Note: Min. 6d common hold down nails or similar device shall be inserted in alternating directions. ¹Other seismic detailing may be required. Please visit or for more information. 45 USG Exterior Ceiling Applications

47 ZXLA with Sheetrock Lay-In Ceiling Panel ClimaPlus Seismic Perimeter Applications Floating Perimeter Treatment Options 1 ACM7 Seismic Clip 8" max. attach ACM7 clip to 12 ga. hanger wire wall through the top holes of the clip wings AX or ZXLA main or cross tee screw attach through center of slot into bulb 3 /4" Sheetrock Lay-In Ceiling Panel ClimaPlus hold-down nail to prevent panel uplift (see accompanying section detail) ACM7 clip M7A molding 29 Wall Molding 12 ga. hanger wire AX or ZXLA main or cross tee 8" max. blocking for perimeter ends of tees to prevent uplift stabilizer bar Sheetrock Lay-In Ceiling Panel ClimaPlus hold-down nail to prevent panel uplift (see accompanying section detail) M20A molding 1 3 /4" Note: 3/49 gap shown for typical seismic design categories D-F. 3/89 gap is typical for seismic design category C. Hold-Down Nail tee min. 6d common hold-down nails or similar device shall inserted in alternating directions Sheetrock Lay-In Ceiling Panel ClimaPlus Note: Min. 6d common hold down nails or similar device shall be inserted in alternating directions. ¹Other seismic detailing may be required. Please visit or for more information. 46 USG Exterior Ceiling Applications

48

49 Product Information DXFEV Data Sheet AC3304. See usg.com for the most up-to-date product information. Installation Must be installed in compliance with ASTM C636, ASTM E580, CISCA, and standard industry practices. Code Compliance The information presented is correct to the best of our knowledge at the date of issuance. Because codes continue to evolve, check with a local official prior to designing and installing a ceiling system. Other restrictions and exemptions may apply. This is only intended as a quick reference. Progressive Engineering Inc. Evaluation Report Compliance Wind load tested and listed in PEI Evaluation Report, PER Purpose This technical guide is intended as a resource for design professionals, to promote more uniform criteria for plan review and jobsite inspection of projects. This technical guide indicates an acceptable method for achieving compliance with applicable codes and regulations, although other methods proposed by design professionals may be considered and adopted. The renderings and details provided are for illustrative purposes only and are not a substitute for certified architectural and engineering drawings. ICC Evaluation Service, Inc., Report Compliance Suspension systems manufactured by USG Interiors, LLC, have been reviewed and are approved by listing in ICC-ES Evaluation Report Evaluation Reports are subject to reexamination, revision and possible cancellation. Please refer to usgdesignstudio.com or usg.com for current reports. L.A. Research Report Compliance Donn brand suspension systems manufactured by USG Interiors, LLC, have been reviewed and are approved by listing in the following L.A. Research Report number: Notice We shall not be liable for incidental and consequential damages, directly or indirectly sustained, nor for any loss caused by application of these goods not in accordance with current printed instructions or for other than the intended use. Our liability is expressly limited to replacement of defective goods. Any claim shall be deemed waived unless made in writing to us within thirty (30) days from date it was or reasonably should have been discovered. Trademarks The following are trademarks of USG Interiors, LLC. or a related company: Aqua-Tough, AX, Celebration, ClimaPlus, Donn, Durock, Fiberock, Fineline, Paraline, Paraline Plus, Securock, Sheetrock, USG, USG in stylized letters, and ZXLA. Safety First! Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read SDS and product literature before specification and installation. Manufactured by USG Interiors, LLC 550 West Adams Street Chicago, IL usg.com seismicceilings.com sustainableceilings.com usgdesignstudio.com SC2561/rev , USG Corporation and/or its affiliates. All rights reserved. Printed in U.S.A.

Code Compliance Meets the requirements for suspended ceilings in accordance with the 2012 International Building Code.

Code Compliance Meets the requirements for suspended ceilings in accordance with the 2012 International Building Code. Pei Evaluation Service is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Product Evaluation Report represents a product that Pei ES has Evaluated and this product has a

More information

Seismic Technical Guide

Seismic Technical Guide Technical Document Seismic Technical Guide Light Duty Suspension Systems ASTM C635 1 addresses the load carrying capability of main tees, categorizing them as Light, Intermediate or Heavy Duty. This is

More information

Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F

Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F NWCB Technical Document SUSPENDED CEILINGS 401 Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F 10/09 This document has been revised based on current Building Code standards.

More information

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance Pei Evaluation Service is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Assembly Evaluation Report represents a product that Pei ES has Evaluated. This Assembly Evaluation

More information

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER: 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-3336 Reissued 01/2015 This report is subject to renewal 01/2017. DIVISION: 09 00 00 FINISHES

More information

Technical Services Information Bureau

Technical Services Information Bureau Technical Services Information Bureau INSTALLING ACOUSTICAL LAY-IN TYPE CEILINGS IN SEISMIC REGIONS AUGUST 2009 UPDATED MAY 2017 TECHNICAL BULLETIN This document covers the installation practices recognized

More information

SEISMIC CEILING SUSPENSION

SEISMIC CEILING SUSPENSION Better. Faster. Easier. Reliable. Efficient. Compliant. SEISMIC CEILING SUSPENSION Fast. Easy. Customer Focused. Seismic Codes: Development and Adoption Purpose of Installation Requirements for Suspended

More information

Suspension System Data Center Ceiling Solutions

Suspension System Data Center Ceiling Solutions Hardware That Needs to be Purchased Separately Screws are fine listed as shown: Min 1-1/4" or longer #8 Truss head self-tapping screws for attaching structural wall angle, lateral support bar 16" or 4"

More information

USG Tile & Flooring Solutions. Lightweight cement board. Easy to cut and fasten. Faster installation USG DUROCK BRAND CEMENT BOARD INSTALLATION GUIDE

USG Tile & Flooring Solutions. Lightweight cement board. Easy to cut and fasten. Faster installation USG DUROCK BRAND CEMENT BOARD INSTALLATION GUIDE USG Tile & Flooring Solutions Lightweight cement board Easy to cut and fasten Faster installation USG DUROCK BRAND CEMENT BOARD INSTALLATION GUIDE USG DUROCK BRAND CEMENT BOARD For more than 30 years,

More information

Set Your Design Apart. Drywall. Suspension System

Set Your Design Apart. Drywall. Suspension System Set Your Design Apart Drywall Suspension System Offices Lobbies Conference Rooms Schools Drywall ceilings take a dramatic new shape with the USG drywall suspension system. This advanced system is pre-engineered

More information

Basic Suspension Systems

Basic Suspension Systems CEILING & WALL SYSTEMS Commercial Ceilings and Walls Solutions Guide Installing Armstrong Suspended Ceilings The ceiling system is made up of Armstrong panels which are supported by a suspension system

More information

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD ASSEMBLIES SECTION 09 21 16 GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Metal stud wall and ceiling framing, 20 gauge. B. Metal channel suspended ceiling framing. C. Gypsum board. D. Gypsum sheathing.

More information

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131 ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 Subject to Renewal: 10/27/09 Issued: 10/27/08 Visit for current status Revised 11/5/08 Page 1 of 10 Solatube International, Inc 2210 Oak

More information

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS REPORT HOLDER: WORTHINGTON ARMSTRONG VENTURE (WAVE)

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS REPORT HOLDER: WORTHINGTON ARMSTRONG VENTURE (WAVE) 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2311 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 09 00

More information

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 07/13/2014 Issued: 07/13/2012 Visit www.ati-es.com for current status Revised: 08/22/2012 Page 1 of

More information

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel

More information

stucco/ plaster GrId systems HanGInG and FramInG stucco/plaster CeIlInGs

stucco/ plaster GrId systems HanGInG and FramInG stucco/plaster CeIlInGs Stucco/ Plaster Grid SystemS Hanging and Framing Stucco/Plaster Ceilings faster. easier. better. Armstrong Drywall Framing Systems install faster than traditional methods, which helps you complete jobs

More information

Gold Bond BRAND Gypsum Sheathing

Gold Bond BRAND Gypsum Sheathing BRAND 09 06 29 16 00/NGC 43/NGC brand is a moisture-resistant sheathing installed on the outside of exterior framing as a substrate for exterior claddings. It is manufactured with a treated water-resistant

More information

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN STEEL STUD AND TRACK FOR DRYWALL PARTITIONS TAKE ADVANTAGE OF THE SAVINGS IN TIME

More information

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1812 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 09 00

More information

SECTION GYPSUM WALLBOARD. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION GYPSUM WALLBOARD. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. SECTION 092116 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting

More information

Shaftwall & Stairwell Systems Fire protection & sound isolation for shafts & stairwells

Shaftwall & Stairwell Systems Fire protection & sound isolation for shafts & stairwells Shaftwall & Stairwell Systems Fire protection & sound isolation f shafts & stairwells what the job demands Shaftwall & Stairwell Systems Fire protection & sound isolation systems f elevat shafts, stairwells

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3462 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 07 00

More information

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No. SECTION 092900 GYPSUM BOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

AND ACCESSORIES FOR DRYWALL CONSTRUCTION STEEL TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION Quality in your corner. THE STRENGTH WITHIN MONTREAL TORONTO CALGARY EDMONTON VANCOUVER STEEL TRIMS AND ACCESSORIES for Construction BAILEY HAS YOUR

More information

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016. ICC-ES Evaluation Report ESR-894 Reissued April 04 This report is subject to renewal April, 0. www.icc-es.org (800) 4-87 () 99-04 A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL

More information

A. This Section includes ceilings consisting of acoustical panels and exposed suspension systems.

A. This Section includes ceilings consisting of acoustical panels and exposed suspension systems. SECTION 09 51 13 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

I-STUD Shaftwall System

I-STUD Shaftwall System I-STUD Shaftwall System Summit Tower I-Stud and CertainTeed Shaftliner TM MILL CERTIFIED Steel-Con 00% GALVANIZED Steel Construction Systems UL Evaluation Report No. ER3660-02 Intertek The I-Stud is approved

More information

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: HOMASOTE COMPANY

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: HOMASOTE COMPANY 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1374 Reissued 06/2017 This report is subject to renewal 06/2018. DIVISION: 09 00

More information

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,

More information

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 NOTICE OF ACCEPTANCE

More information

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD SECTION 09250 GYPSUM BOARD PART 1GENERAL 1.1 SUMMARY A. Related Documents: General and Supplementary Conditions of the Contract, Division 1 - General Requirements, and Drawings are collectively applicable

More information

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008 SECTION 092900 - GYPSUM BOARD 1.1 SUMMARY A. This Section includes the following: 1. Interior gypsum board. 2. Tile backing panels. B. Related Sections include the following: 1. Division 06 Section "Rough

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: EQUITONE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: EQUITONE 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3910 Issued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00

More information

USG Ceiling Solutions. LOGIX Integrated Ceiling Systems SYSTEMS GUIDE

USG Ceiling Solutions. LOGIX Integrated Ceiling Systems SYSTEMS GUIDE USG Ceiling Solutions LOGIX Integrated Ceiling Systems SYSTEMS GUIDE SYSTEMS GUIDE Logix Brand Integrated Ceiling Systems from USG allow you to design ceilings that meet building requirements without

More information

SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM. U.L. FIRE RATED Head-of-Wall Joint Systems

SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM. U.L. FIRE RATED Head-of-Wall Joint Systems SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM U.L. FIRE RATED Head-of-Wall Joint Systems 1-800-275-2279 STEELER INC. SLOTTED STUD 1-800-275-2279 The STEELER SLOTTED STUD is an innovative

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: PACIFIC WOODTECH CORPORATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: PACIFIC WOODTECH CORPORATION 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1225 Reissued 10/2017 This report is subject to renewal 10/2019. DIVISION: 06 00

More information

CEILING SYSTEMS. DRYWALL GRID and FRAMING SYSTEM. Between us, ideas become reality

CEILING SYSTEMS. DRYWALL GRID and FRAMING SYSTEM. Between us, ideas become reality CEILING SYSTEMS Between us, ideas become reality DRYWALL GRID and FRAMING SYSTEM Pre-engineered systems from Armstrong are designed so you know what the details of finished installations will look like

More information

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700 SECTION 09 5113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3340 Reissued 05/2017 This report is subject to renewal 05/2018. DIVISION: 07 00 00 THERMAL

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1015 Reissued 04/2017 This report is subject to renewal 04/2019. DIVISION: 07 00

More information

HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction.

HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction. HACKER SOUND MAT II HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction. HACKER SOUND MAT II, a recycled rubber sound

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 6587 (562) 699 0543 www.icc es.org ESR 3152 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

The GlasRoc Shaftliner Type X advantage...

The GlasRoc Shaftliner Type X advantage... C e r t a i n T e e d SHAFTLINER F o r A r e a S e p a r a t i o n F i r e w a l l s Shaftliner S Type X for Area Separation GlasRoc Shaftliner is a specially formulated product for applications where

More information

Fire protection for townhouses that share a common wall. AreaSeparationWall Systems

Fire protection for townhouses that share a common wall. AreaSeparationWall Systems Fire protection for townhouses that share a common wall AreaSeparationWall Systems Area separation walls between adjoining townhouses must provide fire-resistive ratings to ensure the safety of occupants

More information

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS REPORT HOLDER: PANEL REY

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS REPORT HOLDER: PANEL REY 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-3752 Reissued 10/2015 This report is subject to renewal 10/2016. DIVISION: 09 00 00 FINISHES

More information

ESR-2015P* Reissued April 2014 This report is subject to renewal April 1, 2015.

ESR-2015P* Reissued April 2014 This report is subject to renewal April 1, 2015. ICC-ES Evaluation Report ESR-2015P* Reissued April 2014 This report is subject to renewal April 1, 2015. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 095113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 DEFINITIONS A. AC: Articulation

More information

SECTION ACOUSTICAL PANEL CEILINGS

SECTION ACOUSTICAL PANEL CEILINGS SECTION 095113 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER: 0 Most idely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-687 (62) 699-043 www.icc-es.org ESR-199 Reissued 0/2017 This report is subject to renewal 0/2019. DIVISION: 07 00 00 THERMAL AND MOISTURE

More information

PER See all Pei ES Listings at:

PER See all Pei ES Listings at: Pei Evaluation Service is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Product Evaluation Report represents a product that Pei ES has Evaluated and has a Follow-up Service

More information

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (00) 423-657 (562) 699-0543 www.icc-es.org ESR-2064 Reissued 11/2017 This report is subject to renewal 11/201. DIVISION: 07 00 00

More information

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SUPERWALL MANUFACTURING, INC.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SUPERWALL MANUFACTURING, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2214 Reissued 08/2017 This report is subject to renewal 07/2019. DIVISION: 09 00

More information

APPLICATION AND FINISHING OF GYPSUM PANEL PRODUCTS

APPLICATION AND FINISHING OF GYPSUM PANEL PRODUCTS GYPSUM ASSOCIATION SPECIFICATIONSI I 6525 Belcrest Road, Suite 480, Hyattsville MD 20782 APPLICATION AND FINISHING OF GYPSUM PANEL PRODUCTS GA-216-2013 This document may be revised or withdrawn from circulation

More information

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1 GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials and services to furnish and install SECURITY

More information

Integrated LIGHTING. Solutions

Integrated LIGHTING. Solutions Integrated LIGHTING Solutions Lighting INTEGRATION Made Easy We understand the pain points of trying to integrate lighting into the ceiling plane, while being able to specify and maintain the crisp, clean

More information

Soar to New Heights. Curvatura. 3-Dimensional System

Soar to New Heights. Curvatura. 3-Dimensional System Soar to New Heights Curvatura 3-Dimensional System Offices Retail Entertainment High-bay Areas The Curvatura 3-D System gives you the freedom to create dramatic three-dimensional curved designs that combine

More information

USG Drywall Grid. Suspension System

USG Drywall Grid. Suspension System USG Drywall Grid Suspension System Apartments Hotels Retail Malls Banks Lobbies Schools Medical Industrial Food Preparation Areas The USG Boral Drywall Grid Suspension System is expressly designed for

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 092500 - GYPSUM BOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

1. Interior gypsum wallboard. 2. Exterior gypsum board panels for ceilings and soffits. 3. Tile backing panels.

1. Interior gypsum wallboard. 2. Exterior gypsum board panels for ceilings and soffits. 3. Tile backing panels. SECTION 09260 - GYPSUM BOARD ASSEMBLIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

REPORT HOLDER: WARE INDUSTRIES, INC. (DBA Marino\WARE) 400 METUCHEN ROAD SOUTH PLAINFIELD, NEW JERSEY EVALUATION SUBJECT:

REPORT HOLDER: WARE INDUSTRIES, INC. (DBA Marino\WARE) 400 METUCHEN ROAD SOUTH PLAINFIELD, NEW JERSEY EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2620 Reissued 07/2017 This report is subject to renewal 07/2019. DIVISION: 05 00

More information

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM SECTION 13 34 21 - STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM PART 1 - GENERAL 1.1 DESCRIPTION A. The structural retrofit roof sub-framing system will provide support for a new metal roofing system constructed

More information

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3831 Reissued 12/2017 This report is subject to renewal 12/2018. SECTION: 09 29 00

More information

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 689 Reissued 07/206 This report is subject to renewal 07/208. DIVISION: 07 00 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC. 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2937 Reissued 05/2016 This report is subject to renewal 05/2018. DIVISION: 07 00 00 THERMAL

More information

ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95

ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95 ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95 TEST PROCEDURE FOR STATIC UPLIFT RESISTANCE OF MECHANICALLY ATTACHED, CLIPPED, RIGID, ROOF SYSTEMS (For Methods of Mechanical Attachment Excluding Clips,

More information

AC R1 # Triangle Parkway Suite 100 Norcross, Ga Phone: Fax: AC R1. September 11, 2012

AC R1 # Triangle Parkway Suite 100 Norcross, Ga Phone: Fax: AC R1. September 11, 2012 AC70-1012-R1 #12 AC70-1012-R1 #12 AC70-1012-R1 September 11, 2012 Mr. Brian Gerber Ms. Elyse Levy International Code Council Evaluation Service (ICC ES) 5360 Workman Mill Road Whittier, CA 90601 2256 RE:

More information

SECTION ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL

SECTION ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL SECTION 09511 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.01 DESCRIPTION: A. Work under this section is subject to requirements of the Contract Documents including the General Conditions and Supplementary

More information

Optima Vector Plank. Installation Instructions. Ceiling

Optima Vector Plank. Installation Instructions. Ceiling Ceiling Systems Between us, ideas become reality Optima Vector Plank Installation Instructions 1. GENERAL 1.1. Product Description The Vector products referenced in these instructions are made from fiberglass.

More information

POST FRAME BUILDING STANDARDS

POST FRAME BUILDING STANDARDS CASS COUNTY, MISSOURI BUILDING CODES, ENVIRONMENTAL HEALTH AND ZONING DEPARTMENT 30508 S. West Outer Road, Harrisonville, MO 64701 P- (816) 380-8134 F- (816) 380-8130 POST FRAME BUILDING STANDARDS 201.3

More information

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal March 1, 2015

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal March 1, 2015 ICC-ES Evaluation Report ESR-1694 Reissued March 2014 This report is subject to renewal March 1, 201 www.icc-es.org (800) 423-687 (62) 699-043 A Subsidiary of the International Code Council DIVISION: 07

More information

SHORTSPAN. Features. Components

SHORTSPAN. Features. Components Armstrong DGS ShortSpan is a fast and easy solution for framing short spans and an economical alternative to TCR and Furring Channel constructions. Features ShortSpan enables framing without suspension

More information

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California *Revised April 2003

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California *Revised April 2003 PFC-5804* Reissued February 1, 2003 ICBO Evaluation Service, Inc. 5360 Workman Mill Road, Whittier, California 90601 www.icboes.org Filing Category: DESIGN Wood PACIFIC WOODTECH CORPORATION PWI JOISTS

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2653 Reissued 09/2016 This report is subject to renewal 09/2018. DIVISION: 07 00

More information

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2732 Reissued 11/2017 This report is subject to renewal 11/2019. DIVISION: 09 00

More information

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1530 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 03 00

More information

Endure 900 Suspended Ceiling Installation Guide

Endure 900 Suspended Ceiling Installation Guide Endure 900 Suspended Ceiling Installation Guide World Commerce Center 2000 Ring Way Road, St. Augustine, FL 32092 Phone: 800-227-8566 or 904-584-1400 www.rulonco.com Receipt and Storage: a. All material

More information

Integrated. Solutions

Integrated. Solutions Integrated Lighting Solutions Lighting Integration Made Easy We understand the pain points of trying to integrate lighting into the ceiling plane, while being able to specify and maintain the crisp, clean

More information

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC. 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-3720 Reissued 09/2016 This report is subject to renewal 09/2018. DIVISION: 09 00 00 FINISHES

More information

TECHNICAL NOTE On Cold-Formed Steel Construction

TECHNICAL NOTE On Cold-Formed Steel Construction TECHNICAL NOTE On Cold-Formed Steel Construction $5.00 6a 1996 Light Gauge Steel Engineers Association Washington, D.C. Toll-Free: 1 (866) 465-4732 www.lgsea.com DESIGN GUIDE FOR PERMANENT BRACING OF COLD-FORMED

More information

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS WOOD CHAPTER 3 301 SCOPE This chapter prescribes construction requirements for buildings where all exterior walls above the foundation are wood framed

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR THE TESTING AND ANALYSIS OF STEEL SHEET SHEATHING FOR WOOD AND COLD FORMED STEEL LIGHT

More information

LP OSB Sheathing & Structural 1 Sheathing

LP OSB Sheathing & Structural 1 Sheathing Rated OSB Sheathing Roof Panels Span Ratings Max. Live Load Thickness Span Rating for Roofs (lbs)** 3/8" 24/0 30 7/16" 24/16 40 15/32" 32/16 70 1/2" 32/16 70 19/32" 40/20 130 23/32" 48/24 175 1-1/8" 48

More information

PinkWood Ltd. Revised September 29, 2017

PinkWood Ltd. Revised September 29, 2017 Fire-Rated Assemblies PR-S315 PinkWood Ltd. Revised September 29, 2017 Products: Series I-Joists PinkWood Ltd., 5929 6 th St. NE, Calgary, Alberta, Canada T2K 5R5 (403) 279-3700 www.pinkwood.ca 1. Basis

More information

FROM: PROPOSED SUBSTITUTION: Use HILTI X-CW Ceiling Wire for Suspended Ceiling Systems

FROM: PROPOSED SUBSTITUTION: Use HILTI X-CW Ceiling Wire for Suspended Ceiling Systems DATE: PROJECT: TO: FROM: SUBJECT: HILTI X-CW CEILING WIRE FASTENER SUBSTITUTION REQUEST SPECIFICATION TITLE: SECTION: PAGE: ARTICLE/PARAGRAPH: DESCRIPTION: DESIGN DETAIL NO.: PROPOSED SUBSTITUTION: Use

More information

Retain "Preinstallation Conference" Paragraph below if Work of this Section is extensive or complex enough to justify a conference.

Retain Preinstallation Conference Paragraph below if Work of this Section is extensive or complex enough to justify a conference. SECTION 05 40 00 - COLD-FORMED METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

METALWORKS Blades Classics

METALWORKS Blades Classics METALWORKS Blades Classics Assembly and Installation Instructions Sold by the: Pcs/Ctn METALWORKS BLADES CLASSICS ITEMS: Item # Item Name Incl with Blades Classics 8155 22.5 x 4 x 1" with two factory installed

More information

Originally Issued: 05/20/2013 Revised: 07/07/2017 Valid Through: 05/31/ Design

Originally Issued: 05/20/2013 Revised: 07/07/2017 Valid Through: 05/31/ Design BRADY INNOVATIONS, LLC. PROX HEADER SYSTEM CSI Section: 05 05 23 Metal Fastenings 05 40 00 Cold-formed Metal Framing 1.0 RECOGNITION Brady Innovations, LLC s ProX Header System recognized in this report

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1517 Reissued 11/2016 This report is subject to renewal 11/2018. DIVISION: 07 00

More information

CI/SfB (35) Xy [ Between us, ideas become reality. ] September 2005 FLAT. DrywallGridSystem. Technical Guide CURVED

CI/SfB (35) Xy [ Between us, ideas become reality. ] September 2005 FLAT. DrywallGridSystem. Technical Guide CURVED CEILING SYSTEMS CI/SfB (35) Xy [ Between us, ideas become reality. ] September 2005 FLAT Technical Guide CURVED Index Page FEATURES and BENEFITS 1 COMPONENTS 2 Main Runners Cross Tees Perimeter Treatment

More information

SECTION COLD-FORMED METAL FRAMING

SECTION COLD-FORMED METAL FRAMING SECTION 05400 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work of this Section shall include all materials and installation necessary to provide all cold formed metal framing. B. This Section includes:

More information

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1663 Reissued 03/2017 This report is subject to renewal 03/2019. DIVISION: 03 00 00 CONCRETE

More information

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3428 Reissued 07/2017 This report is subject to renewal 07/2019. DIVISION: 07 00

More information

Code Compliance Research Report CCRR-0194

Code Compliance Research Report CCRR-0194 Code Compliance Research Report CCRR-0194 Issued: 09-16-2013 Renewal Due: 09-16-2018 Revised: 10-12-2017 DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 05 23 Wood, Plastic, and Composite

More information

where high efficiency is the standard

where high efficiency is the standard Access Doors 2016 where high efficiency is the standard Experience Milcor offers years of experience in the manufacture of a broad range of products and services for residential, commercial, institutional

More information

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

A. This Section includes acoustical panel ceilings installed with exposed suspension systems. SECTION 09511 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3145 Reissued 02/2017 This report is subject to renewal 02/2018. DIVISION: 05 00 00 METALS SECTION:

More information

2000 POCKET DOOR TECHNICAL DATA

2000 POCKET DOOR TECHNICAL DATA 2000 POCKET DOOR TECHNICAL DATA KWIK-WALL... One Source for Wall Systems. KWIK-WALL s s for the 2000 Series - Steel Panel operable wall systems answer the challenge for space division needs posed by multi-purpose

More information

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590

More information