1 Armacell Product Selection Guide Guide for selecting fiber-free, mold-resistant mechanical insulation from the makers of Armaflex The IAQ Insulation Exclusive EPA-registered antimicrobial Supports LEED initiatives advanced insulation

2 2 Armacell Product Selector Product Selector Application REFRIGERATION, HOT & COLD LINES, CHILLED WATER HVAC Interior & exterior DUCT SYSTEMS MECHANICAL SYSTEMS, CHILLERS Product Energy saving Code compliant Thermally efficient Moisture resistant Mold resistant 25/50 rating Low VOC, formaldehyde free Fiber free Energy saving Code compliant 25/50 rating Tough, durable Flexible Energy saving Code compliant Moisture resistant Mold resistant 25/50 rating Fiber free Noise blocking Outdoors: Maintenance-free, UV-resistant Energy saving Code compliant Thermally efficient Moisture resistant Mold resistant 25/50 rating Sheet & roll forms Easy to cut and fabricate Recommended Product AP Armaflex, AP Armaflex SS (Self-Seal) Armaflex Coil AP Armaflex W AP Armaflex, AP Armaflex SS AC Accoflex Armaflex Coil AP Armaflex Self-Adhering (SA) Duct Liner/Wrap and AP Armaflex SA Sheet AP Coilflex AP Armaflex AP Armaflex Sheet and Rolls Armacell Product Specs Specifications Test Method Btu in./h ft 2 F (W/mK) 75 F mean temperature (24 C) 90 F mean temperature (32 C) ASTM C 177 or C 518 AP Armaflex FS Tubes, Sheet & Rolls 0.28 (0.040) (0.041) AP Armaflex Tubes 0.25 (0.036) (0.037) Perm-inch. [Kg/(s m Pa)] ASTM E 96, Procedure A 0.08 [1.16 x ] 0.05 [0.725 x ] AP Armaflex Sheet, Rolls, Duct Liner/Wrap AP Coilflex 0.25 (0.036) (0.037) 0.05 [0.725 x ] (AP Armaflex) Flame Spread and Smoke Developed Index ASTM E 84 CAN ULC S /2" and 2" Thick 25/50 25/50 UL94 V-5VA 25/50 Microban Antimicrobial Protection Yes Yes Yes Water Absorption, % by Volume ASTM C 209 Meets Meets Meets Upper Use Limit 220 F (105 C) 220 F (105 C) 180 F (82 C) Lower Use Limit ➀ -297 F (-183 C) -297 F (-183 C) -297 F (-183 C) Ozone Resistance ASTM C 1071 Excellent Good Good Ultraviolet (UV) Resistance QUV Chamber Test Excellent Third Party Certification Factory Mutual Approvals Yes Yes Yes GREENGUARD Certified IAQ Yes Yes Yes GREENGUARD Certified for Children and Schools Yes Yes Yes ➀ At temperatures below -20 F (-29 C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation. For applications of -40 F to -297 F (-40 C to -183 C) contact Armacell.

3 Armacell Product Selector 3 MECHANICAL SYSTEMS, CHILLERS INDUSTRIAL, PHARMACEUTICAL, MARINE & OFFSHORE SOLAR residential PLUMBING Energy saving Code compliant Thermally efficient Moisture resistant Mold resistant 25/50 rating Sheet & roll forms Easy to cut and fabricate Energy saving Thermally efficient Moisture resistant 25/50 rating Flexible Durable, UV-resistant outdoors Energy saving Code compliant Thermally efficient High temperature range for solar collectors Mold resistant Flexible Energy saving Economical Thermally efficient Moisture resistant 25/50 rating Fiber free Noise blocking AP Armaflex AP Armaflex Sheet and Rolls AP Armaflex Arma-Chek NH Armaflex UT Solaflex Tubolit AC Accoflex Tubes NH Armaflex UT Solaflex ArmaTuff Tubolit 0.27 (0.039) (0.040) 0.27 (0.039) (0.040) 0.28 (0.046) (0.041) 0.08 [1.16 x ] 0.05 [0.725 x ] 0.08 [1.16 x ] 25/50 30/200 Meets EB 4013, SOLAS,USN test. Toxicityfree* UL94 V-O 0.25 (0.036) (0.037) 0.25 (0.036) 0.05 [7.25 x ] 0.00 Laminate 25/50 UL-94-V-0 (for exterior application) 25/50 No No No No No Meets Meets Meets Meets Laminate [0.0 x ] Meets 220 F (105 C) 250 F (120 C) 300 F (150 C) 180 F (82 C) 200 F (93 C) -297 F (-183 C) -297 F (-183 C) -297 F (-183 C) -297 F (-183 C) -200 F (-129 C) Good Excellent Excellent Excellent Good Excellent Excellent Excellent Yes Excellent Yes Yes Yes Yes Yes Yes Yes

4 4 Armacell Product Selector AP Armaflex, AP Armaflex W and AP Armaflex SS (Self-Seal) Pipe Insulation through 1 Wall Factory Mutual (FM) Approvals AP Armaflex is approved through continuing supervision by Factory Mutual Approvals: Thermal Conductivity: 0.25 BTU-in/hr. ft 2 F Water Vapor Transmission: 0.05 perm-inch Fire Rating: will not contribute significantly to fire (simulated end-use testing) Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. AP Armaflex, AP Armaflex W and AP Armaflex SS (Self-Seal) Pipe (Tube) Insulation is a black or white closed cell, fiber-free elastomeric foam and the world s most recognized brand of flexible mechanical insulation. Self-seal version enables faster, labor saving installation. Code Compliant: 25/50-rated through 1 wall. Acceptable for use in air plenums. Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required. Mold resistant: Made with EPA-registered Microban antimicrobial product protection. Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes. Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools. Durable: No fragile vapor retarder and lasts the life of the mechanical system. Retards heat gain and controls condensation drip from chilledwater and refrigeration systems. Reduces heat flow for hot-water plumbing, liquid-heating and dual temperature piping. Acceptable for use in air plenums. 25/50-rated through 1 (25 mm). Normally requires no supplemental vapor-retarder protection. Armaflex insulation installs with Armaflex 520 Adhesive. However, Self-Seal (SS) saves labor and installed costs only the butt joints require adhesive coating. For below ground applications, contact Armacell or see Technical Bulletin No. 7 on our website, Outdoors, a weather-resistant protective finish is to be applied. Armaflex WB Finish is recommended. ASTM C 534, Type I Tubular Grade 1 ASTM E 84, NFPA 255, UL 723 CAN/ULC S102 UL 94 5V-5A, V-O, File E NFPA 90A, 90B UL 181 ASTM G-21/C1338, ASTM G-22 ASTM D 1056, 2B1 MIL-P-15280J, FORM T (Black) MIL-C-3133C (MIL STD 670B), Grade SBE 3* Black only MEA M* City of LA RR 7642* * Non-SS (Self-Seal) only BTU in./h ft 2 F (W/mK) 75 F mean temperature (24 C) 90 F mean temperature (32 C) 0.25 (0.036) (0.037) ASTM C 177 or ASTM C 518 Perm-inch. [Kg/(s m Pa)] 0.05 [0.725 x ] ASTM E 96, Procedure A Flame Spread and Smoke Developed Index 25/50* ASTM E 84 CAN/ULC S102 ➂ Water Absorption, % by Volume 0.2% ASTM C 209 Upper Use Limit ➀ 220 F (-183 C)** Lower Use Limit ➁ -297 F (-183 C)* Ozone Resistance Good Sizes Wall thickness, (nominal) Inside diameter, tubular Length of sections, tubular 3/8, 1/2, 3/4, 1, (10, 13, 19 and 25mm) 3/8 ID to 8 ID* (10mm ID to 203mm) 6 (1.8m) ➀ On the heating cycle, AP Armaflex SS Pipe Insulation withstand temperatures as high as 220 F (105 C). 520, 520 Black or 520 BLV Adhesive may be used with pipe insulation applications up to 220 F (105 C). ➁ At temperatures below -20 F (-29 C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation. ➂ AP Armaflex Black tested for CAN/ ULC. AP Armaflex White determined to be comparable. * For applications of -40 F to -297 F (-40 C to -183 C), contact Armacell.

5 Armacell Product Selector 5 AP Armaflex FS Pipe Insulation 1-1/2 and 2 (38 mm and 50 mm) Wall Factory Mutual (FM) Approvals AP Armaflex is approved through continuing supervision by Factory Mutual Approvals: Thermal Conductivity: 0.28 BTU-in/hr. ft2 F Water Vapor Transmission: 0.08 perm-inch Fire Rating: will not contribute significantly to fire (simulated end-use testing) Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. Retards heat gain and controls condensation drip from chilledwater and refrigeration systems. Reduces heat flow for hot-water plumbing, liquid-heating and dual temperature piping. Acceptable for use in air plenums. 25/50-rated through 2. Normally requires no supplemental vapor-retarder protection. For below ground applications, contact Armacell or see Technical Bulletin No. 7 on our website, Outdoors, a weather-resistant protective finish is to be applied. Armaflex WB Finish is recommended. AP Armaflex FS Insulation is a black or white closed cell, fiber-free elastomeric foam, a code compliant 1-1/2 and 2 thick EPDM version of the world s most recognized brand of mechanical insulation. Code Compliant in greater thicknesses: 25/50-rated in 1-1/2 and 2 wall. Acceptable for use in air plenums. Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required. Mold resistant: Made with EPA-registered Microban antimicrobial product protection. Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes. Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools. Durable: No fragile vapor retarder and lasts the life of the mechanical system. ASTM C 534, Type I and II Tubular Grade 1 ASTM C 1534 ASTM E 84, NFPA 255, UL 723 UL 94 5VA, File E NFPA 90A, 90B UL 181 ASTM G-21/C1338 ASTM G-22 ASTM D 1056, 2B1 MEA M City of LA RR 7642 BTU in./h ft 2 F (W/mK) 75 F mean temperature (24 C) 90 F mean temperature (32 C) 0.28 (0.040) (0.037) ASTM C 177 or ASTM C 518 Perm-inch. [Kg/(s m Pa)] 0.08 [1.16 x ] ASTM E 96, Procedure A Flame Spread and Smoke 25/50 ASTM E 84 Water Absorption, % by Volume 0.2% ASTM C 209 Upper Use Limit ➀ 220 F (105 C) Lower Use Limit ➁ -297 F (-183 C) ASTM C 534 Ozone Resistance Good Sizes Tubes Wall Thickness (nominal) Form Inside Diameter Tubular Form Length 1-1/2 and 2 (38mm and 50mm) 3/8 to 6 IPS (10mm - 173mm) 6 (1.8m) ➀ On the heating cycle, AP Armaflex Pipe Insulation will withstand temperatures as high as 220 F (105 C). 520, 520 Black or 520 BLV Adhesive may be used with pipe insulation applications up to 220 F (105 C). ➁ At temperatures below -20 F (-29 C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency and resistance to water vapor permeability of Armaflex insulation. For applications of -40 F to -297 F (-40 C to -183 C), contact Armacell.

6 6 Armacell Product Selector AP Armaflex Sheet & Roll Insulation and AP Armaflex SA Self-Adhering Sheet & Roll Insulation Factory Mutual (FM) Approvals AP Armaflex is approved through continuing supervision by Factory Mutual Approvals: Thermal Conductivity: 0.25 BTU-in/hr. ft 2 F Water Vapor Transmission: 0.05 perm-inch Fire Rating: will not contribute significantly to fire (simulated end-use testing) Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. AP Armaflex and AP Armaflex SA Self-Adhering Sheet & Roll Insulation is a black closed cell, fiber-free elastomeric foam and the world s most recognized brand of flexible mechanical insulation. Selfadhering version enables faster, labor saving installation. Code Compliant: 25/50-rated through 1 wall. Acceptable for use in air plenums. Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required. Mold resistant: Made with EPA-registered Microban antimicrobial product protection. Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes. Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools. Durable: No fragile vapor retarder and lasts the life of the mechanical system. Retards heat gain and controls condensation drip from chilled-water and refrigeration systems. Reduces heat flow on hot systems. Acceptable for use in air plenums. 25/50-rated through 1 (25 mm). Normally requires no supplemental vapor-retarder protection. Armaflex insulation installs with Armaflex 520 Adhesive. However, Self-Adhering (SA) saves labor and installed costs only the joints require adhesive coating. For below ground applications, contact Armacell or see Technical Bulletin No. 7 on our website, Outdoors, a weather-resistant protective finish is to be applied. Armaflex WB Finish is recommended. ASTM C 534, Type II Sheet Grade 1 ASTM C 1534 ASTM E 84, NFPA 255, UL 723 CAN/ULC S102 (25 mm) UL 94 5V-5A, V-O, File E NFPA 90A, 90B UL 181 ASTM G-21/C1338, ASTM G-22 ASTM D 1056, 2B1 MIL-P-15280J, FORM S MIL-C-3133C (MIL STD 670B), Grade SBE 3 MEA M City of LA RR 7642 BTU in./h ft 2 F (W/mK) 75 F Mean Temperature (24 C) 90 F Mean Temperature (32 C) 0.25 (0.036) (0.037) ASTM C 177 or ASTM C 518 Perm-inch. [Kg/(s m Pa)] 0.05 [0.725 x ] ASTM E 96, Procedure A Flame Spread and Smoke Developed Index through 1 (25mm)* 25/50 ASTM E 84 CAN/ULC S102 Water Absorption, % by Volume 0.2% ASTM C 209 Upper Use Limit ➀ 180/220 F (82/105 C) Lower Use Limit ➁ -297 F (-183 C)** Ozone Resistance Good Sizes: Sheet Width Thickness (nominal) x Length Sizes: Roll Width Thickness (nominal) x Length 36 x 48 (.915m x1.22m) 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/2 & 2 (3, 6, 10, 13, 19, 25, 38 & 50mm) 48 (1.22mm) 60 (1.53m) in 1 thickness only 3/8 x 100 (10mm x 30.5m) 1/2 x 70 (13mm x 21.4m) 3/4 x 50 (19mm x 15.2m) 1 x 35 (25mm x 10.7m) 1-1/2 x 25 (38mm x 7.6m) 2 x 18 (50mm x 5.4m) ➀ When AP Armaflex Sheet is installed by adhering butt joints and seams only, the upper temperature limit is 220 F (105 C) using 520, 520 black, or 520 BLV Adhesive. AP Armaflex Sheet adhered with complete adhesive coverage on flat or curved metal surfaces may be applied to surfaces that will operate as high as 180 F (82 C) using 520, 520 Black, 520 BLV or Armaflex Low VOC Spray Contact Adhesive. ➁ At temperatures below -20 F (-29 C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation. ➂ Reference only. * For 25/50 above 1 (25mm), Please see AP Armaflex FS submittal. 1-1/2 and 2 available in 25/50 and non 25/50. ** For applications of -40 F to -297 F (-40 C to -183 C), contact Armacell.

7 Armacell Product Selector 7 AP Armaflex FS Sheet & Roll Insulation 1-1/2 and 2 (38 mm and 50 mm) Thickness Factory Mutual (FM) Approvals AP Armaflex is approved through continuing supervision by Factory Mutual Approvals: Thermal Conductivity:.28 BTU-in/hr. ft 2 F Water Vapor Transmission: 0.08 perm-in Fire Rating: 25/50 through 2 thickness Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. Retards heat gain and controls condensation drip from chilled-water and refrigeration systems. Reduces heat flow on hot systems. Acceptable for use in air plenums. 25/50-rated through 2 (50 mm). Normally requires no supplemental vapor-retarder protection. Armaflex insulation installs with Armaflex 520 Adhesive. For below ground applications, contact Armacell or see Technical Bulletin No. 7 on our website, Outdoors, a weather-resistant protective finish is to be applied. Armaflex WB Finish is recommended. AP Armaflex FS Sheet & Roll Insulation is a black closed cell, fiberfree elastomeric foam, a code compliant 1-1/2 and 2 thick EPDM version of the world s most recognized brand of mechanical insulation. Code Compliant in greater thicknesses: 25/50-rated in 1-1/2 and 2. Acceptable for use in air plenums. Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required. Mold resistant: Made with EPA-registered Microban antimicrobial product protection. Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes. R-Value rated R-8 at 2 thickness. Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools. Durable: No fragile vapor retarder and lasts the life of the mechanical system. ASTM C 534, Type II Sheet Grade 1 ASTM C 1534 ASTM E 84, NFPA 255, UL 723 UL 94 5VA, File E NFPA 90A, 90B UL 181 ASTM G-21/C1338, ASTM G-22 ASTM D 1056, 2B1 MEA 96-85M City of LA RR 7642 BTU in./h ft 2 F (W/mK) 75 F mean temperature (24 C) 0.28 (0.040) ASTM C 177 or ASTM C 518 Perm-inch. [Kg/(s m Pa)] 0.08 [1.16 x ] ASTM E 96, Procedure A Flame Spread and Smoke Developed Index through 2 (50mm) 25/50 ASTM E 84 Water Absorption, % by Volume 0.2% ASTM C 209 Upper Use Limit 180 F (82 C) Lower Use Limit ➀ -297 F (-183 C) Ozone Resistance Good Sizes: Sheet Width Thickness (nominal) x Length Sizes: Roll Width Thickness (nominal) x Length 36 x 48 (.915m x 1.22m) 1-1/2 and 2 (38 and 50mm) 48 (1.22mm) and 60 (1.53m) 1-1/2 x 25 (38mm x 7.6m) 2 x 18 (50mm x 5.4m) ➀ At temperatures below -20 F (-29 C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency and resistance to water vapor permeability of Armaflex insulation. ➁ Reference Only * For applications of -40 F to -297 F (-40 C to -183 C), contact Armacell.

8 8 Armacell Product Selector AP Armaflex SA and AP Armaflex FS Duct Liner Factory Mutual (FM) Approvals AP Armaflex is approved through continuing supervision by Factory Mutual Approvals: Thermal Conductivity: AP Armaflex: 0.25, AP Armaflex FS 0.08 BTU-in/hr. ft 2 F Water Vapor Transmission: AP Armaflex: 0.05, AP Armaflex FS 0.08 perm-in Fire Rating: 25/50 through 2 thickness ➀ Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. AP Armaflex SA (Self-Adhering) and AP Armaflex FS Black Duct Liners are patented*, non-fibrous duct liner with an advanced pressure sensitive adhesive system for non-pinned applications. They can also be applied as a duct wrap to existing duct work. Code Compliant in greater thicknesses: 25/50-rated through 2. Acceptable for use in air plenums. Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required. Mold resistant: Made with EPA-registered Microban antimicrobial product protection. Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes. Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools. Durable: No fragile vapor retarder and lasts the life of the mechanical system. Self-Adhering (SA) system saves labor and installed costs only the joints require adhesive coating. Ideal for air handling systems, VAV units, ducts and other air system components requiring condensation control, or resistance to moisture, damage or heat gain. Excellent for reducing HVAC noise, especially in low frequency ranges. Performance peaks at 500 Hz, a critical frequency in a duct system. Application areas include schools, hospitals, hotels, commercial and public buildings. Acceptable for use in air plenums. AP Armaflex SA 25/50-rated through 1 (25 mm). Where 25/50-rated R-6 or R-8 is required, select AP Armaflex FS in 1-1/2 or 2 thicknesses. ASTM C 534, Type II Sheet Grade 1 ASTM C 1534 ASTM E 84, NFPA 255, UL 723 CAN/ULC S102 (25 mm) UL 94 5VA, File E NFPA 90A, 90B UL 181 Btu in./h ft 2 F (W/mK) 75 F mean temperature (24 C) 90 F mean temperature (32 C) Perm-inch. [Kg/(s m Pa)] Flame Spread and Smoke Developed Index ➀ AP Armaflex 0.25 (0.036) (0.037) ASTM G-21/C1338, ASTM G-22 ASTM D 1056, 2B1 MIL-P-15280J, FORM S MIL-C-3133C (MIL STD 670B), Grade SBE 3 MEA M City of LA RR 7642 US Patent Thermal Duct Lining Insulation for lining variable air volume boxes, air handling units, and ducts for heat ventilation and air conditioning AP Armaflex FS 0.05 [0.725 x ] 0.08 [1.16 x ] Through 1 (25 mm) 25/ (0.040) (0.041) ASTM C 177 or C /2 and 2 25/50 ASTM E 96, Procedure A ASTM E 84 CAN ULC S-102 AP through 1 Water Absorption, % by Volume 0.2% ASTM C 209 Upper Use Limit ➁ Lower Use Limit ➂ Erosion Resistance 180 F (82 C) -297 F (-183 C) Does not break away, flake off or show evidence or delamination at velocities of 10,000 ft/min ASTM C 1071 Corrosiveness Noncorrosive ASTM C 665 Odor Emissions No objectionable odors ASTM C 665 ➀ AP Armaflex SA Duct Liner has a flame spread index of less than 25 and a smoke developed index of less than 50 for all thicknesses up to and including 1 (25 mm) when tested according to ASTM E 84 and CAN ULC S-102. AP Armaflex FS has a flame spread index of less than 25 and a smoke developed index of less than 50 for all thicknesses up to and including 1-1/2 and 2 when tested according to ASTM E 84 and CAN ULC S-102. Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. ➁ Withstands temperature of 250 F (121 C) when tested according to ASTM C 411. Test Method for Surface Performance of High-Temperature Insulations. At this temperature, AP/ Armaflex SA Duct Liner insulation shows no evidence of flaming, glowing, smoldering, delamination, melting or insulation collapse. Although this insulation will withstand high temperatures, continuous use temperature should be limited to 180 F (82 C). ➂ At temperatures below -20 F (-29 C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation.

9 Armacell Product Selector 9 Sound Absorption Coefficients at Frequency Thickness 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC Nom. 1 (25 mm) ASTM C 423 with ASTM E 795 Type A Mounting Sound Transmission Class (STC) Sizes Thickness STC Class Sheet Width / Length 36 x 48 Nom. 1/2 (13 mm) 25 Nom. 1 (25 mm) 25 Roll Width Wall Thickness 48 (all thicknesses) and 60 (1 only) AP Armaflex: 3/8, 1/2, 3/4 and 1 AP Armaflex FS: 1-1/2 and 2 AP Armaflex SA and AP Armaflex FS Black Duct Liners / Wraps Patented* for Air Systems that Require an Alternative Duct Liner / Wrap Features Advanced, aggressive PSA Closed cell structure Made with Microban antimicrobial product protection Smooth surface that reduces dirt and debris accumulation Elastomeric material Inherent vapor retarder Benefits No pinning required, faster installation Resists moisture, nonwicking Reduced water presence in system and insulation Noise blocking Nondusting Longer life Won t contribute to air quality problems Resists mold on the insulation EPA registered for use in air duct insulation Inhibits amplification of biological contaminants Basis for continuing system hygiene Fiber free Resistant to incidental damage No special tools; no dust mask required during fabrication and installation Requires no mastics Competitive total installed cost * US Patent Thermal Duct Lining Insulation for lining variable air volume boxes, air handling units, and ducts for heat ventilation and air conditioning.

10 10 Armacell Product Selector AP Coilflex Conformable Duct Liner Ratings Thermal Conductivity: 0.25 BTU-in/hr. ft 2 F Fire Rating: will not contribute significantly to fire (simulated end-use testing) Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. Ideal for air handling systems, VAV units, ducts and other air system components requiring condensation control, or resistance to moisture, damage or heat gain. Excellent for reducing HVAC noise, especially in low frequency ranges. Performance is twice as effective as fiberglass at 500 Hz, a critical frequency in a duct system. Application areas include schools, hospitals, commercial buildings. AP Coilflex Duct Liner is a patent-pending*, cost-effective, and highly conformable non-fibrous acoustic duct liner created for automated applications with water-based adhesives in accordance with SMACNA pinning and spacing guidelines, or unpinned applications using an Armaflex 520 Adhesive. It can also be applied as a duct wrap to existing duct work. Practical and Cost Saving: Easily conforms to fabricated duct corners without stiffness or bulging and compression; requires fewer cuts and expensive encapsulation or inner wall. Exceptional Acoustic Performance: Superior sound absorption at low frequencies critical top speech intelligibility. Mold resistant: Made with EPA-registered Microban antimicrobial. Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes. R-Value of 4.2. Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools. Durable: No fragile vapor retarder and lasts the life of the mechanical system. Acceptable for use in air plenums. 25/50-rated through 1 (25 mm). Normally requires no supplemental vapor-retarder protection. ASTM C 534, Type II Sheet Grade 1 ASTM C 1534 ASTM E 84, NFPA 255, UL 723 CAN/ULC S102 (25 mm) UL 94 5VA, File E NFPA 90A, 90B UL 181 ASTM G-21/C1338, ASTM G-22 ASTM D 1056, 2B1 * US Patent Thermal Duct Lining Insulation for lining variable air volume boxes, air handling units, and ducts for heat ventilation and air conditioning Btu in./h ft 2 F (W/mK) 75 F mean temperature (24 C) 90 F mean temperature (32 C) 0.25 (0.036) (0.037) ASTM C 177 or C 518 Flame Spread and Smoke Developed Index ➀ Through 1 (25 mm) 25/50 ASTM E 84 Upper Use Limit ➁ 180 F (82 C) Lower Use Limit ➂ -297 F (-183 C) Erosion Resistance Does not break away, flake off or show evidence or delamination at velocities of 10,000 ft/min ASTM C 1071 Corrosiveness Noncorrosive ASTM C 665 Odor Emissions No objectionable odors ASTM C 665 Sound Absorption Coefficients at Frequency Thickness 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC Nom. 1 (25mm) Sound Transmission Class (STC) Thickness STC Class Nom. 1/2 (13 mm) 25 Nom. 1 (25mm) 25 Sizes Roll Width 46, 47, 48, 56-1/4, 59 and 60 Wall Thickness 1 1/2 (special order) ➀ AP Coilflex Duct Liner has a flame spread index of less than 25 and a smoke developed index of less than 50 for all thicknesses up to and including 1 (25 mm) when tested according to ASTM E 84. Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. ➁ Withstands temperature of 250 F (121 C) when tested according to ASTM C 411. Test Method for Surface Performance of High-Temperature Insulations. At this temperature, AP Coilflex Duct Liner insulation shows no evidence of flaming, glowing, smoldering, delamination, melting or insulation collapse. Although this insulation will withstand high temperatures, continuous use temperature should be limited to 180 F (82 C). ➂ At temperatures below -20 F (-29 C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency of Coilflex insulation. ASTM C 423 with ASTM E 795 Type A Mounting

11 Armacell Product Selector 11 NH Armaflex Pipe, Sheet & Roll Insulation and NH Armaflex SA Roll Insulation Closed-cell material that eliminates toxic gases that may threaten personnel and sensitive electronic equipment including effects from chlorines, bromines and PVC. Used as insulation and protection for piping, tanks, and air ducts, and to prevent stress corrosion with stainless steel pipes in the following applications: US Navy applications General shipbuilding IMO (International Maritime Organization) Nuclear power plants Other areas where nonhalogenated or chlorine-free materials may be required NH Armaflex Insulation is a nonhalogen elastomeric insulation developed for sweat control in environments that require specific protection against smoke containing acid gases. It is also available selfadhering (SA) in roll form. Innovative: The first nonhalogen flexible insulation introduced for shipboard use. Safety first: Fire tested at the Naval Research Laboratory (NRL) in controlled comparisons with baseline materials. Further testing through DDG-51 and NSSN produced references that NH Armaflex scored better than MIL-P-15280J materials such as AP Armaflex. Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required. Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. SA (Self-adhering) is the reduced VOC version. Durable: No fragile vapor retarder and lasts the life of the mechanical system. Electric Boat Corporation Specification EB 4013 Antisweat and Refrigerant Insulation Systems (Sheets and Tubes) International Maritime Organization (IMO) SOLAS United States Coast Guard * Nominal Sizes 1/2 (13 mm) NH Armaflex is currently specified for use on US Navy vessels UL-V-O and HF-1 File Number E55798 ASTM C534 Type 1 (Tubular) Grade 3, Type II (Sheet) Grade 3 ASTM C795 Nuclear Regulatory Commission Regulatory Guide /4 (19 mm) Thickness 1 (25 mm) Tube 6 (1.8 m) in length Available in nominal pipe sizes from 3/8 to 8 (1 thickness special order) Sheet 3 x 4 (0.915 m X 1.22 m) Roll 4 (1.22 m) width *Available special order only. 70 (21.4 m) length 50 (15.2 m) length Available 35 (10.7 m) length 1-1/2 (38 mm) Not Available 25 (7.6 m) length BTU in./h ft 2 F (W/mK) 32 F mean temperature (0 C) 75 F mean temperature (24 C) 104 F mean temperature (40 C) (0.036) 0.27 (0.039) (0.041) ASTM C 177 or ASTM C 518 Perm-inch. [Kg/(s m Pa)] 0.05 [0.725 x ] ASTM E 96, Procedure A Water Absorption, % by Volume 0.2% ASTM C 209 Upper Use Limit 250 F (120 C) Lower Use Limit ➀ -297 F (-183 C) ASTM C 534 Ozone Resistance Excellent ASTM D 1149 Toxicity IMO (International Organization) Behavior in Fire Free from Halogen/Dioxin/CFC/Mercury/Carbon Black/Heavy Metal Combustion Gas Concentration (Pass) Smoke Density (Pass) Heat Release Rate (Pass) Flame Spread (Pass) Does not support progressive flaming, will not melt or drip. Meets EB 4013 Meets IMO SOLAS requirements Navy Large Marinetime Scale Pipe Insulation Room/ Corner Test ➀ At temperatures below -20 F (-29 C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation. Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified.

12 12 Armacell Product Selector UT Solaflex Pipe Insulation Closed-cell structure provides low thermal conductivity, excellent fire and smoke behavior, low temperature flexibility and excellent protection against water vapor diffusion. No painting is necessary for performance of the product. (However, all elastomeric-based cellular insulation will show surface defects after prolonged exposure to UV radiation. Painting will minimize these defects.) Performs on a broad range of metal pipes and tubing in piping and collectors, refrigeration-hot gas and dual temperature piping, automotive (under hood) and low pressure steam lines. Oil-resistant as tested by ASTM Oil No. 1 and No. 3. UT Solaflex Tube and Roll Insulation is a UL-listed closed cell, fiberfree, 25/50-rated flexible EPDM elastomeric foam insulation for high temperature, UV-resistant and oil-resistant applications. Innovative: New generation of insulation for solar collectors, refrigeration (including hot gas piping) and automotive. High temperature: Remains flexible at temperatures up to +300 F (+150 C), with intermittent exposure to +350 F (+175 C). Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, resists mold. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools. Durable: No fragile vapor retarder and lasts the life of the mechanical system. ASTM C 534, Type I Tubular Grade 2, Type II (Sheet), Grade 2 UL 94 UL 94 5VA, V-P, File E BTU in./h ft 2 F (W/mK) 75 F mean temperature (24 C) 0.28 (0.040) ASTM C 177 or ASTM C 518 Perm-inch. [Kg/(s m Pa)] 0.08 [1.16 x ] ASTM E 96, Procedure A Flame Spread and Smoke Developed Index through 1 (25mm) UV Weather Resistance 25/50 ASTM E 84 Excellent Upper Use Limit ➀ 300 F (150 C) Lower Use Limit ➁ -297 F (-183 C) Ozone Resistance Excellent ASTM D 1149 Sizes: Tubes Wall thickness, (nominal) Inside diameter, tubular Length of sections, tubular Sizes: Rolls Width Thickness x Length 1/2, 3/4, 1 (13, 19, 25mm) 1/2 through 2-1/2 IPS (13mm to 63.5mm) 6 (1.8m) 48 (1.2m) 1/2 x 70 (13mm x 21.3m) 3/4 x 50 (19mm) x 15.2 m) 1 x 35 (25mm x 10.7m) QUV Chamber Test ASTM G90 (EMMAQUA) ➀ Suitable for systems with occasional or intermittent temperatures to 350 F (175 C), with a recommended exposure limit of one 30 minute period at 350 F (175 C) over 24 hours of operation. ➁ At temperatures below -20 F (-29 C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of UT Solaflex insulation.

13 Armacell Product Selector 13 ArmaTuff Laminated Sheets and Rolls Uses and Applications ArmaTuff is designed to be used for all exterior applications: Exterior ducts, tanks, vessels, large pipes and fittings. The laminate is resistant to UV, ozone, acid rain and most industrial pollutants. No painting is required. Application ArmaTuff is the premiere Armacell Coating System for outdoor applications. It provides a tough metal surface on Armaflex insulation for superior protection against ultraviolet radiation and punctures. Maintenance-free: UV- and damage resistant 10 mil laminate Long-lasting protection: 10-year membrane limited warranty Flexible application: Available with or without PSA Color: White Description ArmaTuff is installed using Armaflex Adhesives or with pre-applied pressure sensitive adhesive (PSA) for application to large, flat or curved metal surfaces such as ducts, vessels, very large pipes or tanks. The seams must be installed in compression and sealed with Armaflex Adhesives. Cover the seam with ArmaTuff Seal Tape. Armaflex 520 Adhesive is a contact adhesive: therefore it must be applied to both surfaces, allowed to get tacky, and the surfaces joined with pressure. Exterior duct work must be pitched to allow rain water to run off the insulation. ArmaTuff is designed for installation in above ground applications. Armaflex insulation products must be installed according to Installation of Armaflex Insulations brochure. Proper installation is required to assure Armaflex insulation performance. The application temperature should be above 40 F (+4 C) and 100 F (+38 C). Finishing the Installation with ArmaTuff Seal Tape ArmaTuff is a complete insulation system providing durable, UVresistant and maintenance-free outdoor performance. Tape is backed with pressure sensitive adhesive and designed to provide protection along the seams and exposed edges of the insulation. Tape is supplied in rolls 6 -wide for sealing seams and exposed edges of ArmaTuff. ArmaTuff is Armaflex insulation with a 12 mil laminated covering membrane. The membrane has a 10-year limited warranty against break-down due to UV radiation. Armaflex is a mold-resistant flexible elastomeric thermal insulation. Its closed-cell structure prevents condensation and moisture wicking, and makes it an efficient insulation. It is manufactured without the use of CFCs, HFCs or HCFCs. It is available in 36 x 48 sheets (with or without pressure sensitive adhesive) and in rolls 48 wide (without PSA), in 1, 1-1/2, 2 thicknesses. Btu in./h ft 2 F (W/mK) 75 F Mean Temperature (24 C) 90 F Mean Temperature (32 C) Perm-in. [Kg/(s m Pa)] 0.25 (0.036) (0.037) ASTM C 177 or C 518 Laminate 0.00 Foam 0.05 ASTM E 96, Procedure A Water Absorption, % by Volume 0.2% / 0.0% laminate ASTM C 209 Upper Use Limit 180 F (82 C) ➀ At temperatures below -20 F (-29 C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of ArmaTuff. ➁ Reference only. * For applications of -40 F to -297 F (-40 C to -183 C), contact Armacell. Lower Use Limit ➀ -297 F (-183 C)* UltraViolet (UV) Resistance Excellent Chemical Resistance Excellent ASTM G 90 QUV Chamber Weatherability Excellent ASTM D471 Durability Excellent Sizes: Sheet With or Without Adhesive Width and Length Thickness (nominal) Sizes: Roll Without Adhesive Width Thickness (nominal) x Length 36 x 48 (0.915 m x 1.22 m) 1, 1-1/2 and 2 (25, 38 and 50 mm) 48 (1.22 m) 1 x 35 (25 mm x 10.7 m) 1-1/2 x 25 (38 mm x 7.6 m) 2 x 18 (50 mm x 5.4 m)

14 14 Armacell Product Selector Tubolit Pipe Insulation, Tubolit SS Self Seal, Tubolit White SS, Tubolit W Tape Ratings Thermal Conductivity: 0.25 BTU-in/hr. ft 2 F Water Vapor Transmission: 0.00 perm-inch Fire Rating: 25/50 Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. Reduces heat loss on hot water plumbing and heat gain on coldwater plumbing systems. Recommended for use on lines operating from -200 F (-129 C) to 200 F (93 C). Normally requires no supplemental vapor-retarder protection. Tubolit insulation installs with Armaflex 520 Adhesive. However, Self-Seal (SS) products save labor and installed costs only the butt joints require adhesive coating. Outdoors, a weather-resistant protective finish is to be applied. Armaflex WB Finish is recommended. Tubolit Pipe (Tube) Insulation is an economical thermal solution from Armacell, the makers of Armaflex and the world s leading supplier of tubular polyethylene insulation. Self-seal versions enable faster, labor saving installation. Proven: Used worldwide for insulating domestic hot and cold plumbing lines. Economical: Cost-saving polyethylene. Tubolit White SS is a costcompetitive fiber-free 6 alternative to 3 fiberglass. The associated Tubolit W Tape is compatible with standard fitting covers. Energy efficient: Reduces heat loss and gain. Moisture resistant: Closed cell structure prevents condensation and wicking; no supplemental vapor retarder required. Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOCs. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools. Quiet: Reduces plumbing noise. Resists Mold and Mildew ASTM C 1427, Type I MEA 6-02M BTU in./h ft 2 F (W/mK) 75 F (24 C) mean temperature 0.25 (0.036) ASTM C 177 or ASTM C 518 Perm-inch. [Kg/(s m Pa)] 0.0 ASTM E 96, Procedure A Flame Spread and Smoke Developed Index through 1 (25 mm) Thickness ➁ 25/50 ASTM E 84 Upper Use Limit ➀ 180 F (-129 C) Lower Use Limit ➁ -200 F (-129 C) Ozone Resistance Good Sizes Wall Thickness (nominal) Inside Diameter, Tubular Length of Sections, Tubular Tape 3/8, 1/2, 3/4 and 1 (10, 13, 19 and 25 mm) 3/8 to 4 IPS ID (10 mm to 114 mm ID) 6 (1.83 m) 2 wide x 60 ➀ Average values are not to be used for writing material specifications. Contact Armacell for specification ranges. ➁ Cellular plastics and thermoplastics, such as polyethylene/polyolefin insulation, that may drip, melt, delaminate or draw away from the fire, present unique problems and require careful interpretation of the test results. ➂ For reference only.

15 Armacell Product Selector 15 Insulation Products for Mechanical Systems Armaflex Adhesives Armaflex 520 and Armaflex 520 Black Adhesives are air-drying contact adhesives that are excellent for joining seams and butt joints of AP and NH Armaflex Pipe and Sheet Insulation and Tubolit Pipe Insulation. Where a low V.O.C. adhesive is required, use Armaflex 520 BLV Adhesive. 520 Adhesives meet MIL-A-24179A and Amend-2 as Type II, Class Adhesives when dried to a film meet codes and specifications of less than 25 for flame spread and less than 50 for smoke (ASTM E 84). Armaflex WB Finish Armaflex WB Finish is a white water-based latex enamel for use over all forms of Armaflex insulations. It provides a protective semi-gloss finish for both indoor and outdoor applications. Armaflex WB Finish brushes or rolls on easily. Its water base formulation makes it fastdrying without solvent fumes. Cleans up with soap and warm water. Armaflex WB Finish is supplied in gallon and quart containers. Impervious to moisture. Outdoors, is exceptionally durable and weather resistant to ultraviolet (UV) and ozone. Outdoor surfaces should be recoated every 2-4 years. Armacell Fabricated Fittings Armacell Fabricated Fittings are madeto-order and prefabricated using the world s highest quality, closed cell insulation. Available in wall thicknesses up to 2, these fittings are labor saving, easy to work with and apply, and provide total Armaflex system integrity. Options include 90-degree elbows (2-piece and 3-piece), T s, 45-degree elbows, grooved fittings (AP Armaflex black) and grooved couplings Armaflex Low VOC Spray Contact Adhesive, green in color, is supplied in 27 pound aerosolized canisters. The product contains no chlorinated solvents such as methylene chloride and does not contain ozone depleting compounds. Complies with SCAQMD rule 1168 for volatile organic compound content less than <5 g/l. Dried film meets the fire building codes of flame spread index of less than 25 and smoke developed index of less than 50. Excellent for bonding Armaflex sheet and roll insulations to vessels, tanks, ducts and mechanical equipment operating at temperatures below 180 F (82 C). Armafix IPH, NPH Pipe Hangers Armafix is used to support Armaflex and Armaflex NH (nonhaogen)insulated pipes with pre-insulated hangers that retard heat gain and control condensation drip from chilledwater and refrigeration systems. See Armafix Submittal Sheet for details. Insulation Tape AP Armaflex Insulation Tape is made of high-quality AP Armaflex insulation. Available in tape dispenser form, the expanded closedcell structure makes it an efficient insulation. Made with Microban antimicrobial product protection, our tape is also formaldehyde free, low VOCs, fiber free, dust free and resists mold and mildew. Provides a fast, easy method for insulating pipes and fittings. Reduces heat loss when applied to hot-water lines that operate up to 180 F (82 C). AP Armaflex Tape may be used with AP Armaflex Pipe and Sheet Insulation.

16 The Armacell Advantage Building Relationships That Endure Armacell is an easyaccess organization that values customers as business partners. Support is available for help with installation, clarifying technical and code compliance issues, and specification assistance. Customer Service: The Armacell Customer Service Team has earned a reputation as the best in our industry. Teams from manufacturing, logistics and customer service meet daily to anticipate surges in demand, monitor service levels, and promptly resolve any customer inconveniences. Application Assistance: Guidance and training for installers, from the experts who trained an industry. Technical Assistance: Expertise to help solve application problems and clarify technical and code compliance issues. Specification Assistance: Expertise in helping with specifications and providing the right solutions for the most demanding specification criteria. Call :00 a.m. 4:30 p.m. EST M-F for assistance. World Leader in Mechanical Insulation Armacell is the global leader in mechanical insulation and foam technologies. Armacell developed Armaflex, the world s first elastomeric thermal insulation and continues to provide product solutions to meet the challenges of thermal efficiency, condensation control, indoor air quality, sound attenuation and long-lasting performance. Armacell has unrivaled global capabilities bolstered by 20 manufacturing facilities in 13 countries. Globally integrated research and development allows our scientists and technicians to benchmark global practices and adapt them to either global or regional requirements, codes or specifications. ARMACELL LLC 7600 Oakwood Street Extension Mebane, NC TEL: FAX: info.us@armacell.com INTERNET: advanced insulation NA NA 2011 Armacell LLC Printed in United States of America MICROBAN is a registered trademark of Microban Products Company. The GREENGUARD INDOOR AIR QUALITY CERTIFIED Mark is a registered certification mark used under license through the GREENGUARD Environmental Institute.

PRODUCT SELECTION GUIDE

PRODUCT SELECTION GUIDE Fiber Free PRODUCT SELECTION GUIDE Quick guide for selecting fiber-free, mold-resistant mechanical insulation from the makers of Armaflex GREENGUARD Certified products are certified to GREENGUARD standards

More information

Tube Insulation. Fiber Free

Tube Insulation. Fiber Free Fiber Free Tube Insulation Fiber-free, flexible, elastomeric pipe insulation for reliable protection against condensation, mold, energy loss and ultraviolet radiation in residential and commercial applications

More information

We solved the science of safely insulating air ducts.

We solved the science of safely insulating air ducts. We solved the science of safely insulating air ducts. Patented duct liners eliminate fibers, stop mold, reduce noise while they insulate. Armaflex : The IAQ Insulation AP Armaflex SA Black Duct Liner Mold

More information

We solved the science of safely insulating air ducts.

We solved the science of safely insulating air ducts. We solved the science of safely insulating air ducts. Patented duct liners eliminate fibers, stop mold, reduce noise while they insulate. Armaflex : The IAQ Insulation Now you can safely insulate & quiet

More information

GUIDE SPECIFICATION: DUCT LINER

GUIDE SPECIFICATION: DUCT LINER GUIDE SPECIFICATION: DUCT LINER This specification guide includes thermal & acoustical insulation for ductwork and air handling systems. This section is based on the format recommended by MICA (Midwest

More information

Master Insulation Guide Specification for Mechanical Systems

Master Insulation Guide Specification for Mechanical Systems for Mechanical Systems AP Armaflex Pipe Insulation AP Armaflex W Pipe Insulation AP Armaflex SS Pipe Insulation AP Armaflex Sheet and Roll Insulation AP Armaflex SA Sheet and Roll Insulation ArmaTuff Laminated

More information

K-FLEX DUCT LINER GRAY

K-FLEX DUCT LINER GRAY K-FLEX DUCT LINER GRAY Flexible, Closed Cell Elastomeric Foam Insulation Responsive to Market Industry & Product Expertise 3rd Party Certified Products 25/50-rated up to 2 thick Systems Approach Factory-applied

More information

TOTALINE COPPER TUBING

TOTALINE COPPER TUBING TOTALINE COPPER TUBING TOTALINE COPPER TUBE AIR CONDITIONING & REFRIGERATION P744 WEIGHT PER TUBE 3/8.030 2.30 ACR-20 x 3/8 1/2.035 3.70 ACR-20 x 1/2 5/8.040 5.30 ACR-20 x 5/8 3/4.042 6.70 ACR-20 x 3/4

More information

GUIDE SPECIFICATION: MECHANICAL SYSTEMS

GUIDE SPECIFICATION: MECHANICAL SYSTEMS GUIDE SPECIFICATION: MECHANICAL SYSTEMS This specification guide includes thermal & acoustical insulation for piping, equipment, vessels, and air handling systems. This section is based on the format recommended

More information

The Right Insulation for Indoor Air Quality

The Right Insulation for Indoor Air Quality AP Armaflex The Closed Cell Solution The Right Insulation for Indoor Air Quality ADDED PROTECTION FOR COLD SYSTEMS AND AIR HANDLING SYSTEMS Prevents moisture intrusion Inhibits mold and mildew Fiber free,

More information

The Right Insulation for Cold Systems

The Right Insulation for Cold Systems AP Armaflex The Closed Cell Solution The Right Insulation for Cold Systems PREVENTS MOISTURE INTRUSION AND ITS CONSEQUENCES Ensures long-term thermal performance Inhibits mold and mildew, protects IAQ

More information

Chilled Water. Product performance for insulation of chilled water piping

Chilled Water. Product performance for insulation of chilled water piping Chilled Water Product performance for insulation of chilled water piping ABOUT K-FLEX USA K-FLEX USA IS A LEADING MANUFACTURER of flexible, closed cell elastomeric insulation for mechanical piping, air

More information

Plumbing Pipe Insulation Specification Submitted by: Armacell LLC. Plumbing Pipe Insulation Specification Armacell LLC 1

Plumbing Pipe Insulation Specification Submitted by: Armacell LLC. Plumbing Pipe Insulation Specification Armacell LLC 1 Plumbing Pipe Insulation Specification 2005 Armacell LLC 1 Part 1 General 1.01 Scope of Work: A. Provide piping insulation as specified below. The purpose of the thermal pipe insulation is for condensation

More information

Insulation engineered to prevent condensation and energy loss

Insulation engineered to prevent condensation and energy loss Insulation engineered to prevent condensation and energy loss Triple security: effective condensation control, FM Approved and excellent fire performance Highly energy efficient to give long-term energy-saving

More information

Ammonia. Product performance for insulation of ammonia piping

Ammonia. Product performance for insulation of ammonia piping Ammonia Product performance for insulation of ammonia piping ABOUT K-FLEX USA K-FLEX USA IS A LEADING MANUFACTURER of flexible, closed cell elastomeric insulation for mechanical piping, air handling units

More information

Knauf Data Sheet AH-DS-5E Friendly Feel. Duct Wrap. with ECOSE Technology

Knauf Data Sheet AH-DS-5E Friendly Feel. Duct Wrap. with ECOSE Technology Knauf Data Sheet AH-DS-5E 07-09 Friendly Feel with ECOSE Technology Duct Wrap For cooling, heating or dual temperature service. Friendly Feel Duct Wrap meets the most stringent IAQ tests GREENGUARD Children

More information

SECTION PIPING INSULATION

SECTION PIPING INSULATION SECTION 23 07 19 PIPING INSULATION PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Piping insulation for refrigerant piping within building envelope. 2. Furnishing and installation of insulation.

More information

K-FLEX USA MECHANICAL INSULATION CONTENTS: SPECIFICATION GUIDE PRODUCT SELECTION GUIDE LEED CONTRIBUTION GUIDE

K-FLEX USA MECHANICAL INSULATION CONTENTS: SPECIFICATION GUIDE PRODUCT SELECTION GUIDE LEED CONTRIBUTION GUIDE CONTENTS: SPECIFICATION GUIDE PRODUCT SELECTION GUIDE LEED CONTRIBUTION GUIDE SPECIFICATION GUIDE This specification guide includes thermal & acoustical insulation for piping, equipment and vessels, and

More information

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket.

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket. SECTION 230719 - HVAC PIPING INSULATION PART 1 GENERAL 1.1 SECTION INCLUDES A. Piping insulation. B. Jackets and accessories. 1.2 RELATED REQUIREMENTS A. Section 07813 - Fire Procection, HVAC & Plumbing

More information

FM APPROVED. FIRE PERFORMANCE Differences Between Elastomeric and Polyethylene/Polyolefin Insulations

FM APPROVED. FIRE PERFORMANCE Differences Between Elastomeric and Polyethylene/Polyolefin Insulations FIRE PERFORMANCE Differences Between Elastomeric and Polyethylene/Polyolefin Insulations Why a 5/50 rating alone does not assure fire safety FM APPROVED FIRE PERFORMANCE: A 5/50 RATING DOES NOT ASSURE

More information

Standard and Mini Split Line Sets

Standard and Mini Split Line Sets For HVACR Applications Job Name Job Location Engineer Contractor Wholesaler Linesets, Inc. Rep Product Description: Linesets, Inc. Standard and Mini Split Line Sets are available in either an elastomeric,

More information

SECTION HVAC INSULATION

SECTION HVAC INSULATION PART 1 GENERAL 1.1 SUMMARY SECTION 23 07 00 HVAC INSULATION A. Section Includes: 1. Ductwork insulation. 2. Duct liner. 3. Insulation jackets. 4. Equipment insulation 5. Piping system insulation. 6. Insulation

More information

Friendly Feel Duct Wrap with KwikStretch Markings. Knauf Data Sheet AH-DS

Friendly Feel Duct Wrap with KwikStretch Markings. Knauf Data Sheet AH-DS Friendly Feel Duct Wrap with KwikStretch Markings Knauf Data Sheet AH-DS-5 05-07 For cooling, heating or dual temperature service. Friendly Feel Duct Wrap meets the most stringent IAQ tests GREENGUARD

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

EXPERIENCE COUNTS! Specializing in more than just products we put the competitive advantage at your fingertips.

EXPERIENCE COUNTS! Specializing in more than just products we put the competitive advantage at your fingertips. EXPERIENCE COUNTS! Specializing in more than just products we put the competitive advantage at your fingertips. Armaflex is a flexible, closed cell, elastomeric, nitrile rubber, insulation. It is a highly

More information

ArmAcell solutions for systems refrigeration, Air- conditioning & VeNtilAtioN

ArmAcell solutions for systems refrigeration, Air- conditioning & VeNtilAtioN ARMACELL SOLUTIONS FOR SYSTEMS REFRIGERATION, AIR- CONDITIONING & VENTILATION AF/Armaflex Armafix AF NH/Armaflex Armafix NH HT/Armaflex Armaflex Duct tubolit Split & duosplit Arma-Chek D Arma-Chek R Arma-Chek

More information

DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION HVAC INSULATION

DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION HVAC INSULATION DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) PART 1 GENERAL 1.01 DESCRIPTION A. Insulate the following: 1. Piping: a. Heating water b. Chilled water c. Condenser water (outdoors with heat

More information

RELIABLE, FLEXIBLE INSULATION TRUSTED TO PREVENT CONDENSATION

RELIABLE, FLEXIBLE INSULATION TRUSTED TO PREVENT CONDENSATION Closed-cell structure increases resistance to water vapor Reduce long-term heat gain and reduce energy loss Engineered wall thickness operates with the same line temperature in the same environment Thermal

More information

HIGH PERFORMANCE ACOUSTIC INSULATING MATERIAL FOR A QUIETER ENVIRONMENT

HIGH PERFORMANCE ACOUSTIC INSULATING MATERIAL FOR A QUIETER ENVIRONMENT HIGH PERFORMANCE ACOUSTIC INSULATING MATERIAL FOR A QUIETER ENVIRONMENT Excellent at reducing the transmission of airborne sound Enhances the insertion loss performance of pipe insulation Flexible, easy

More information

B C M T e c h n i c a l, L L C A v o n I n d u s t r i a l D r. R o c h e s t e r H i l l s, M I P h o n e : T o l

B C M T e c h n i c a l, L L C A v o n I n d u s t r i a l D r. R o c h e s t e r H i l l s, M I P h o n e : T o l P r o d u c t C a t a l o g w w w. p i p e i n s u l a t i o n. n e t B C M T e c h n i c a l, L L C 2 1 7 5 A v o n I n d u s t r i a l D r. R o c h e s t e r H i l l s, M I 4 8 3 0 9 P h o n e : 2 4

More information

Aluminum Lagging Roll Jacketing Fittings

Aluminum Lagging Roll Jacketing Fittings Product Catalog Aluminum Lagging DESCRIPTION ITW Pabco/Childers Aluminum Jacketing is the premier protective outer surface for mechanical insulation systems including pipe, vessels, and equipment. It protects

More information

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SECTION DUCT INSULATION

SECTION DUCT INSULATION SECTION 23 07 13 - DUCT INSULATION PART I - GENERAL 1.1 SECTION INCLUDES A. Ductwork Insulation B. Fan and Equipment Insulation C. Insulation Jackets D. Insulation Lagging 1.2 RELATED SECTIONS A. Section

More information

Knauf Data Sheet AH-DS-12e Sonic XP Duct Liner. with ECOSE Technology

Knauf Data Sheet AH-DS-12e Sonic XP Duct Liner. with ECOSE Technology Knauf Data Sheet AH-DS-12e 09-09 Sonic XP Duct Liner with ECOSE Technology Consistent blanket thickness and uniform fiber distribution provides efficient and hassle-free cutting and pinning on all fabrication

More information

PRODUCT CATALOGUE PROFLEXR. Thermal Insulation. CFC free HCFC free Zero Ozone Depletion Potential (ODP) Taking care of energy and Environment

PRODUCT CATALOGUE PROFLEXR. Thermal Insulation. CFC free HCFC free Zero Ozone Depletion Potential (ODP) Taking care of energy and Environment PRODUCT CATALOGUE PROFLEXR Thermal Insulation CFC free HCFC free Zero Ozone Depletion Potential (ODP) Taking care of energy and Environment PROFLEX Proflex polyolefin foam thermal insulation for AirConditioning,

More information

University of Delaware

University of Delaware University Contact: Energy & Engineering Group (302) 831-1744 SECTION 23 07 00_ HVAC INSULATION PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Piping system insulation. 2. Equipment insulation. 3.

More information

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION SECTION 230713 DUCT INSULATION PART 1 GENERAL 1.1 SUMMARY A. Related Sections: 1. 233113 Ductwork and Accessories 1.2 REFERENCES A. American Society for Testing and Materials (ASTM): 1. E84-96a Test Method

More information

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

B. Refer to Section : Air Distribution for lined ductwork requirements.

B. Refer to Section : Air Distribution for lined ductwork requirements. SECTION 230700 MECHANICAL INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

FIRE STATION 55 June 14, 2010

FIRE STATION 55 June 14, 2010 SECTION 15250 MECHANICAL INSULATION PART 1 - GENERAL 1.01 DESCRIPTION A. Work Includes 1. Insulation of Domestic Water Piping. 2. Pipe Insulation of refrigerant piping. 3. Insulation of ductwork. 4. Aluminum

More information

PRODUCT SELECTION GUIDE. HVAC Insulation

PRODUCT SELECTION GUIDE. HVAC Insulation PRODUCT SELECTION GUIDE HVAC Insulation TABLE OF CONTENTS DUCT LINER INSULATION Linacoustic RC 3 Linacoustic RC-HP 3 Linacoustic R-300 3 Spiracoustic Plus 4 Spiral SG 4 LinaTex 4 DUCT BOARD INSULATION

More information

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SECTION SPRAY FOAM INSULATION

SECTION SPRAY FOAM INSULATION SECTION 07 21 29 SPRAY FOAM INSULATION PART 1 GENERAL 1.1 SECTION INCLUDES A. Spray-in-place, light-density, semi-rigid, open-cell polyurethane foam insulation in assemblies indicated on the Drawings,

More information

Air Handling Products

Air Handling Products Full Line Catalog AH-FL-11 05-07 Air Handling Products Air Duct Board-M and AGM, Duct Liner E M, Textile Duct Liner, Rigid Plenum Liner and Duct Wrap A Full Line of Air Handling Products Delivering greater

More information

AIR DISTRIBUTION SOLUTIONS QUIETR ECOTOUCH SOFTR PROCAT

AIR DISTRIBUTION SOLUTIONS QUIETR ECOTOUCH SOFTR PROCAT AIR DISTRIBUTION SOLUTIONS QUIETR ECOTOUCH SOFTR PROCAT Owens Corning Air Distribution Solutions 3 EcoTouch Insulation for Flexible Duct 4 QuietR Duct Board 5 ProCat Blown-in Insulation System 6 QuietR

More information

Insulation Board. Knauf Data Sheet PE-DS

Insulation Board. Knauf Data Sheet PE-DS Insulation Board Knauf Data Sheet PE-DS-2 12-06 Insulation Board Description Knauf Insulation Board is a thermal and acoustical insulation product made from inorganic glass fibers preformed into boards

More information

ARIFLEX. Rubber Insulation Foam Tube & Foam Sheet

ARIFLEX. Rubber Insulation Foam Tube & Foam Sheet ARIFLEX Rubber Insulation Foam Tube & Foam Sheet General Amiantit Group of Companies The Amiantit Group is a leading industrial organization that was established in Dammam, Saudi Arabia in year 1968. Today,

More information

COMPARISON GUIDE TO NON-FIBROUS LINER PERFORMANCE

COMPARISON GUIDE TO NON-FIBROUS LINER PERFORMANCE COMPARISON GUIDE TO NON-FIBROUS LINER PERFORMANCE Performance Counts Selection of a duct lining can be a challenging step in the design process of a building s HVAC system today. Fibrous liners like Johns

More information

TAPE SOLUTIONS FOR HVAC SHURTAPE.COM TAPE

TAPE SOLUTIONS FOR HVAC SHURTAPE.COM TAPE TAPE SOLUTIONS FOR HVAC SHURTAPE.COM 1.888.442.TAPE YOU DEMAND FULL SYSTEM CLOSURE. And rely on tape to get the job done quickly and efficiently. That s why we offer a full portfolio of foil, film and

More information

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology Knauf Data Sheet PE-DS-2e 8-09 Insulation Board with ECOSE Technology Insulation Board with ECOSE Technology Description Knauf Insulation Board with ECOSE Technology is a thermal and acoustical insulation

More information

Redi-Klad 1000 Pipe Insulation

Redi-Klad 1000 Pipe Insulation Knauf Data Sheet PE-DS-16e 12-09 Redi-Klad 1000 Pipe Insulation with ECOSE Technology Knauf Redi-Klad 1000 F Pipe Insulation with ECOSE Technology is offered across a wide range of sizes. For iron pipe

More information

EFRIGERATION INSTALLATION GUIDE

EFRIGERATION INSTALLATION GUIDE R EFRIGERATION INSTALLATION GUIDE Golden Rules for Working with INSTALLATION Armaflex and good adhesive brushes1 fittings. mitered fabricated Use good quality tools and, in particular, fresh 520, 520 Black

More information

SECTION MECHANICAL INSULATION. A. Types of insulation specified in this section include the following:

SECTION MECHANICAL INSULATION. A. Types of insulation specified in this section include the following: SECTION 15250 PART I - GENERAL 1.01 WORK INCLUDED A. Types of insulation specified in this section include the following: 1. Piping System Insulation: a. Domestic Cold Water b. Domestic Hot water c. Heating

More information

Eclipse TM Air Duct Board. Knauf Data Sheet AH-DS

Eclipse TM Air Duct Board. Knauf Data Sheet AH-DS Eclipse TM Air Duct Board Knauf Data Sheet AH-DS-10 01-08 Eclipse Air Duct Board Description Knauf Eclipse Air Duct Board is a rigid fiber glass board faced on one side with a foil-scrim-kraft (FSK) vapor

More information

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation.

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation. SECTION 15083 HVAC DUCT PROTECTION OVER INSULATION FlexClad This section is based on the products of MFM Building Products Corp., which is located at: 525 Orange St. P. O. Box 340 Coshocton, OH 43812 Toll

More information

SECTION SPRAY FOAM INSULATION

SECTION SPRAY FOAM INSULATION SECTION 07 21 29 SPRAY FOAM INSULATION PART 1 GENERAL 1.1 SECTION INCLUDES A. Spray-in-place, light-density, semi-rigid, open-cell polyurethane foam insulation in assemblies indicated on the Drawings,

More information

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE PART 1 - GENERAL 1.1 SUMMARY SECTION 07 27 26 FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit

More information

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

1. Division 23 Section Hangers and Supports for HVAC Piping and Equipment for pipe insulation shields and protection saddles. SECTION 23 07 19 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Praval Adhaulia K-FLEX INDIA PVT LTD

Praval Adhaulia K-FLEX INDIA PVT LTD Praval Adhaulia K-FLEX INDIA PVT LTD IK Insulation Group - Corporate - 2009 Thermal and Acoustic Products Thermal Insulation Is a material having relatively high resistance to heat flow Stationary air

More information

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS I N SULROCK FIRE RATED METAL PANELS GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS 1. GENERAL 1.1. Summary Fire-rated panels as shown on the drawings shall be INSULROCK brand panels as supplied by Green

More information

Vapor-Clear. The high-performance, low-cost, eco-friendly, aesthetically-pleasing alternative to high-build epoxy floors and boring

Vapor-Clear. The high-performance, low-cost, eco-friendly, aesthetically-pleasing alternative to high-build epoxy floors and boring advanced moisture control, inc. The high-performance, low-cost, eco-friendly, aesthetically-pleasing alternative to high-build epoxy floors and boring 250 polished concrete slabs! Made in Southern California,

More information

Mechanical Insulation for Refrigeration Systems

Mechanical Insulation for Refrigeration Systems Mechanical Insulation for Refrigeration Systems INDUSTRIAL REFRIGERATION CONSORTIUM RESEARCH & TECHNOLOGY FORUM MAY 2-3, 2012 Peter Gauchel, President/CEO L&C Insulation Inc. Overview Current trends in

More information

LT/ArmaFlex. Industrial INSULATION FOR THE OIL AND GAS INDUSTRY. High density industrial grade FEF installation

LT/ArmaFlex. Industrial INSULATION FOR THE OIL AND GAS INDUSTRY. High density industrial grade FEF installation INSULATION FOR THE OIL AND GAS INDUSTRY LT/ArmaFlex Industrial High density industrial grade FEF installation // Built-in water vapour barrier mitigates risk of corrosion under insulation (CUI) // Low

More information

ARMAFLEX SHEET AL / KY / AL-KY

ARMAFLEX SHEET AL / KY / AL-KY ARMAFLEX SHEET AL / KY / AL-KY Condensation Control Thermal Insulation It is an elastomeric rubber based insulation material in the form of sheet with closed cell structure. It is manufactured to be used

More information

Pipe & Equipment Insulations Product Selection Guide

Pipe & Equipment Insulations Product Selection Guide Fiber Glass Insulation Pipe & Equipment Insulations Product Selection Guide Icon Key Thermal Acoustical Fire Resistance Moisture Control Formaldehyde-free products for improved indoor air quality For more

More information

Air Duct Board-M with Hydroshield Technology. Knauf Data Sheet AH-DS

Air Duct Board-M with Hydroshield Technology. Knauf Data Sheet AH-DS Air Duct Board-M with Hydroshield Technology Knauf Data Sheet AH-DS-6 08-06 Knauf Air Duct Board-M is faced with a tightly bonded black mat for greater airstream surface durability. Available in both EI-475

More information

A. Deliver material to job site in original, nonbroken, factory packaging, labeled with manufacturer's density and thickness.

A. Deliver material to job site in original, nonbroken, factory packaging, labeled with manufacturer's density and thickness. SECTION 15250 PIPING AND EQUIPMENT INSULATION PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract including General and Supplementary Conditions, Division 1 Specification

More information

a d v a n c e d e l a s t o m e r i c t h e r m a l a n d a c o u s t i c i n s u l a t i o n m a t e r i a l s

a d v a n c e d e l a s t o m e r i c t h e r m a l a n d a c o u s t i c i n s u l a t i o n m a t e r i a l s a d v a n c e d e l a s t o m e r i c t h e r m a l a n d a c o u s t i c i n s u l a t i o n m a t e r i a l s G E N E R A L O V E RV I E W O F P R O D U C T S A N D S Y S T E M S CFC and HCFC-free insulation

More information

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology Knauf Data Sheet PE-DS-2e 4-10 Insulation Board with ECOSE Technology o Shrinkage (ASTM C 356) Less than 0.3% linear shrinkage. Resists Microbial Growth (ASTM C 1338, G21) Does not promote or support the

More information

SECTION SELF-ADHERING SHEET FLASHING

SECTION SELF-ADHERING SHEET FLASHING MANUFACTURER S GUIDE SPECIFICATIONS SECTION 076526 SELF-ADHERING SHEET FLASHING 900 Hensley Lane Wylie TX 75098 800-527-7092 www.carlisleccw.com 604129 03.24.15 Carlisle, Flexphalt, Sure-Seal and CAV-GRIP

More information

SECTION PLUMBING INSULATION

SECTION PLUMBING INSULATION SECTION 22 07 00 PLUMBING INSULATION PART 1 - GENERAL 1.1 SUMMARY A. Section includes equipment insulation, covering, and thermal insulation for piping systems including vapor retarders, jackets and accessories.

More information

THE FIRST CHOICE FOR PROFESSIONAL INSTALLATIONS

THE FIRST CHOICE FOR PROFESSIONAL INSTALLATIONS Powered by TCPDF (www.tcpdf.org) Powered by TCPDF (www.tcpdf.org) THE FIRST CHOICE FOR PROFESSIONAL INSTALLATIONS Increases equipment life cycle High flexibility and ease of installation Reliable condensation

More information

InSuLATInG YouR WoRLd SInCE 1979

InSuLATInG YouR WoRLd SInCE 1979 SPRAY-on InSuLATIon PRoduCTS InSuLATInG YouR WoRLd SInCE 1979 www.monoglass.com CommerCial Residential SportS facilities IndustrIal Marine SPRAY-APPLIEd InSuLATIon Monoglass Spray-On is an engineered product

More information

All Low VOC All the Time

All Low VOC All the Time All Low VOC All the Time DUIT Electrical / Utility Product Guide OUR COMPANY Established in 1954, IPS Corporation has consistently grown over the past 0+ years. Today, we are the trusted leader in manufacturing

More information

SECTION MULTI-USE COMPOSITE ALUMINUM PANELS

SECTION MULTI-USE COMPOSITE ALUMINUM PANELS SECTION 07416 MULTI-USE COMPOSITE ALUMINUM PANELS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Insulation for VRF/VRV HVAC Systems. Variable Refrigerant Flow(VRF) and Variable Refrigerant Volume(VRV) System Insulation Needs

Insulation for VRF/VRV HVAC Systems. Variable Refrigerant Flow(VRF) and Variable Refrigerant Volume(VRV) System Insulation Needs Insulation for VRF/VRV HVAC Systems Variable Refrigerant Flow(VRF) and Variable Refrigerant Volume(VRV) System Insulation Needs Well Sealed, Skill/Detail High Level of Craftsmanship Complete Insulation

More information

Foil-Faced Fiberglass Fabric 84215/9480 HT

Foil-Faced Fiberglass Fabric 84215/9480 HT Foil-Faced Fiberglass Fabric 84215/9480 HT Description Foil-Faced Fiberglass Fabric 84215/9480 HT has been specifically designed as shipboard lagging and jacketing material for use over insulation where

More information

Eclipse Air Duct Board

Eclipse Air Duct Board Knauf Data Sheet AH-DS-10e 03-12 Eclipse Air Duct Board with ECOSE Technology Eclipse Air Duct Board with ECOSE Technology Description Knauf Insulation Eclipse Air Duct Board with ECOSE Technology is a

More information

Eclipse Air Duct Board

Eclipse Air Duct Board Knauf Data Sheet AH-DS-10e 08-09 Eclipse Air Duct Board with ECOSE Technology Knauf s unique blackening process provides a deeper black surface than other standard boards, minimizing visibility at venting

More information

.1 Thermal insulation for insulated piping and piping accessories affected by construction and new pipe sections as indicated on drawings.

.1 Thermal insulation for insulated piping and piping accessories affected by construction and new pipe sections as indicated on drawings. BID OPPORTUNITY NO. 253-2011 PAGE 1 OF 8 PART 1 GENERAL 1.1 SUMMARY.1 Section Includes: 1.2 REFERENCES.1 Thermal insulation for insulated piping and piping accessories affected by construction and new

More information

Knauf Data Sheet CI-DLS-DS Sonic XP. Duct Liner. with ECOSE Technology

Knauf Data Sheet CI-DLS-DS Sonic XP. Duct Liner. with ECOSE Technology Knauf Data Sheet CI-DLS-DS 04-14 Sonic XP with ECOSE Technology Duct Liner Sonic XP Duct Liner with ECOSE Technology Description Knauf Insulation Sonic XP Duct Liner is a flexible, mat-faced insulation

More information

Atmosphere Duct Liner

Atmosphere Duct Liner Data Sheet CI-DLA-DS 02-15 Atmosphere Duct Liner with ECOSE Technology Atmosphere Duct Liner with ECOSE Technology Description Knauf Insulation Atmosphere Duct Liner is a flexible, mat-faced insulation

More information

SECTION ACOUSTICAL PLASTER CEILINGS

SECTION ACOUSTICAL PLASTER CEILINGS SECTION 098316 ACOUSTICAL PLASTER CEILINGS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Division 15 INSULATION Section 15100

Division 15 INSULATION Section 15100 Page 1 of 5 SECTION PAGE PART 1 GENERAL 2 1.1 General 2 1.2 References 2 1.3 Work Included 2 1.4 Related Work 2 1.5 Quality Assurance 3 PART 2 PRODUCTS 3 2.1 Description 3 PART 3 EXECUTION 3 3.1 Workmanship

More information

Thermal Insulation. Physically Crosslinked closed cell polyolefin foam insulation for ducts PHYSICALLY SEKISUI TECHNOLOGY

Thermal Insulation. Physically Crosslinked closed cell polyolefin foam insulation for ducts PHYSICALLY SEKISUI TECHNOLOGY Thermal Insulation LS Physically Crosslinked closed cell polyolefin foam insulation for ducts PHYSICALLY C R O S S L I N K E D SEKISUI TECHNOLOGY The New Standard in Polyolefin Insulation Thermobreak is

More information

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section PIPE AND EQUIPMENT INSULATION

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section PIPE AND EQUIPMENT INSULATION PART 1 GENERAL 1.01 SUMMARY Section 15145 This Section includes insulation for piping and equipment as called out on the Plans. 1.02 MEASUREMENT AND PAYMENT No separate payment will be provided for the

More information

Roxul RHT. Board Roxul RHT. Flex Roxul RHT. Wrap. High Temperature Insulation for Industrial/Mechanical Applications

Roxul RHT. Board Roxul RHT. Flex Roxul RHT. Wrap. High Temperature Insulation for Industrial/Mechanical Applications HigH TemperaTure industrial/mechanical insulation Roxul RHT Board Roxul RHT Flex Roxul RHT Wrap High Temperature Insulation for Industrial/Mechanical Applications roxul rht Protecting High Temperature

More information

LEED POINT ELIGIBLE, AIRTIGHT GREEN POINT CONTRIBUTORS SHURTAPE.COM TAPE

LEED POINT ELIGIBLE, AIRTIGHT GREEN POINT CONTRIBUTORS SHURTAPE.COM TAPE LEED POINT ELIGIBLE, AIRTIGHT GREEN POINT CONTRIBUTORS SHURTAPE.COM 1.888.442.TAPE THE JOB IS COMPLETE once everything is installed, connected, sealed and tested. When building codes require materials

More information

SUPAFLEX SUPAFLEX DESCRIPTION TUBING:

SUPAFLEX SUPAFLEX DESCRIPTION TUBING: SUPAFLEX SUPAFLEX SUPAFLEX DESCRIPTION SUPAFLEX Closed Cell Tubing & Sheet Insulation is a flexible and light weight elastomeric thermal insulation designed for insulating liquid cooling and heating lines,

More information

Thermasheath-XP. Insulation for Exposed Use

Thermasheath-XP. Insulation for Exposed Use Insulation for Exposed Use PRODUCT DESCRIPTION Rmax Thermasheath-XP is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (Polyiso) foam bonded to durable, embossed

More information

Thermoplastic Single Ply & Multi-Ply Roofing Systems

Thermoplastic Single Ply & Multi-Ply Roofing Systems Thermoplastic Single Ply & Multi-Ply Roofing Systems COMMERCIAL INDUSTRIAL INSTITUTIONAL RESIDENTIAL Specializing in Roof Solutions for over 25 years FlexRoofingSystems.com Thermoplastic Single Ply Roof

More information

KwikFlex Pipe & Tank Insulation. Knauf Data Sheet PE-DS

KwikFlex Pipe & Tank Insulation. Knauf Data Sheet PE-DS KwikFlex Pipe & Tank Insulation Knauf Data Sheet PE-DS-15 04-07 Knauf KwikFlex offers a unique combination of fl exibility and compressive strength in a blanket form. Tough and durable, yet easy to handle

More information

International Fireproof Technology Inc.

International Fireproof Technology Inc. International Fireproof Technology Inc. The Ultimate in Firestop Solutions and Fire Protective Coatings www.painttoprotect.com 949-975-8588 Guide Specifications Alternate Thermal and Ignition Barrier IFRM

More information

KwikFlex Pipe & Tank Insulation

KwikFlex Pipe & Tank Insulation Knauf Data Sheet PE-DS-15e 12-09 KwikFlex Pipe & Tank Insulation with ECOSE Technology Knauf KwikFlex offers a unique combination of flexibility and compressive strength in a roll form. Tough and durable,

More information

THE HIGH PERFORMANCE INSULATION FOR AIR CONDITIONING, HEATING, REFRIGERATION AND PLUMBING

THE HIGH PERFORMANCE INSULATION FOR AIR CONDITIONING, HEATING, REFRIGERATION AND PLUMBING THE HIGH PERFORMANCE INSULATION FOR AIR CONDITIONING, HEATING, REFRIGERATION AND PLUMBING Fire tested for vertical pipe chases to NFPA274 Complies with National Construction Code (NCC) Low thermal conductivity,

More information

ProRox 400 Series. Fabricated Industrial Solutions

ProRox 400 Series. Fabricated Industrial Solutions ProRox 400 Series Fabricated Industrial Solutions ROXUL Fabricated Insulation Solutions The ProRox 400 Series fabricated product line offers board (slab) insulation solutions that can be fabricated into

More information

HVAC Piping Insulation FIBERGLAS Insulation. General Specification Guide SECTION

HVAC Piping Insulation FIBERGLAS Insulation. General Specification Guide SECTION HVAC Piping Insulation FIBERGLAS Insulation General Specification Guide PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals,

More information