APPENDIX C SAMPLE ASBESTOS ABATEMENT SPECIFICATION

Size: px
Start display at page:

Download "APPENDIX C SAMPLE ASBESTOS ABATEMENT SPECIFICATION"

Transcription

1 APPENDIX C SAMPLE ASBESTOS ABATEMENT SPECIFICATION The following appendix includes information and standard drawings that are diagrammatic and are used only to convey intent.

2 Guidelines for Use of Sample Asbestos When to use this specification: - University Project Coordinators, Facilities Maintenance staff, and/or Environment, Health, & Safety staff shall use this sample specification for all asbestos abatement projects that are solicited independent of other contracts. - A/E s and/or contractors should reference this document when preparing their specifications for subcontractors. This sample is intended as a template. Sections with italicized red letters shall be replaced with project specific information. Page 2 of 13

3 PROJECT TITLE ASBESTOS ABATEMENT SPECIFICATION PART 1 GENERAL 1.1 ABATEMENT CONTRACTOR'S RESPONSIBILITY The Abatement Contractor shall perform removal of all Asbestos Containing Material (ACM) identified in SPECIAL PROVISIONS 2.1 SCOPE OF WORK. The ACM removal work shall be conducted by a licensed and qualified asbestos abatement contractor. 1.2 ABATEMENT PLAN AND SCHEDULE The Asbestos Abatement Contractor shall plan and schedule asbestos abatement so that the LEAST NUMBER of regulated areas are created as is practicable for project flow. This requirement shall be confirmed by submission of an Abatement Plan prepared by the Abatement Contractor. See Abatement Contractor Submittal requirements in PART 2, SPECIAL PROVISIONS. 1.3 ACCESS DURING ABATEMENT The Asbestos Abatement Contractor shall have access to all abatement areas at the job site. 1.4 UTILITIES FOR ABATEMENT The building's utilities, including power, water, and sanitation may be used during abatement; however, no guarantee as to the reliability of those utilities is made. The Asbestos Abatement Contractor shall be responsible for establishing and maintaining utilities necessary for completion of abatement. PART 2 SPECIAL PROVISIONS 2.1 SCOPE OF WORK The Asbestos Abatement Contractor (Contractor) shall furnish all labor, materials, services, permits, equipment, utility and transportation services required and necessary for the removal, transportation and disposal of ACM and asbestos contaminated materials as specified herein. The asbestos abatement removal items are listed below: Insert abatement items here. Page 3 of 13

4 Abatement shall be completed in conformance with the time schedule requested by the University Project Coordinator. The Contractor shall be responsible for field verifying all conditions and quantities that may affect his work prior to bidding this project. Key items to consider in bidding this work follow: Insert job specific conditions here. Examples include limitations to work hours, occupancy of building or adjacent areas, and unique site conditions. 2.2 BASIS OF BID This is a lump sum project, with the Owner providing opportunities for bidders to access the site during the bid period. The successful bidder shall provide unit prices for all individual abatement items after being notified that they are low bidder. These unit prices shall be used for progress payment purposes and for establishing increases or decreases in the Lump Sum Bid Price due to discovery of changed conditions and/or quantities when the project is proceeding. 2.3 CONTRACTOR QUALIFICATIONS The Owner may accept those Contractors as being qualified if they are licensed as Asbestos Contractors by the State of Nevada, State Board of Contractors, for the appropriate class of work, and who have the appropriate insurance. 2.4 PRE-ABATEMENT CONFERENCE AND JOB BOARD The Contractor s supervisory personnel shall attend a pre-abatement meeting with the Owners Representative at the time and location designated by the Owners Representative. At this meeting the Contractor shall provide three copies of bound submittals, including but not limited to the following: - Schedule: A schedule indicating the approximate dates of all key functions for each abatement area (preparatory work, abatement, clearance, etc.), including shift times. - Abatement Plan and Procedures: The Contractor shall provide an abatement plan with methods and procedures covering each of the identifiable abatement areas. All procedures used shall provide containment of asbestos debris and not allow airborne contamination of adjacent areas. The Abatement Plan shall be approved by the Project Coordinator and the University Environmental, Health, and Safety Department (EH&S) before abatement work may commence. Abatement Plans shall, at a minimum, contain: scope of asbestos related work, containment methods, safe work practices, protection of workers, products to be used, air sampling (personal and area), waste disposal, certification of supervisors/workers, and description of clearance of the abatement area, to include the independent party that will perform clearance inspection and air sampling if removing friable ACM materials greater than ten square feet. The Abatement Plan shall be submitted to the Project Coordinator at least one week prior to commencement of work. If the Pre-abatement conference is less than one week before scheduled work start, the plan must be submitted in advance of the conference. Page 4 of 13

5 - Waste Disposal: The Contractor shall provide the procedure to be followed for handling asbestos waste on removal, packaging, transport and disposal at an approved public asbestos waste disposal site meeting the requirements of CFR 40, Part 61, Subparts A and M. - Emergency Procedures: Emergency procedures, which will be followed at the site in the event of: -- Fire. -- Life-threatening bodily injury inside the containment area. -- A major breach in the containment barrier. -- The detection of unexpected airborne contamination in other parts of the building. -- Splitting or spilling of asbestos debris bags en-route to the dumpster or waste truck. - Safety Data Sheets and Product Data: Contractors shall submit Safety Data Sheets (SDS) and manufacturer s literature for all products they intend to use on the project. - Insurance: The Contractor shall submit insurance certificates verifying insurance coverage as required in Section 2.4, for the Owner's review and approval. - Other Postings: Emergency numbers (24 hours), safety procedures, air monitoring results, and the name and license number of lab performing testing. Dioctylphthalate (DOP) test certifications for Differential Pressure Units (DPUs) and High Efficiency Particulate Air (HEPA) vacuums, shall be conspicuously placed within the near vicinity of containment areas, as directed by the Owner or Owner's Representative. - Project Office Layout: The Contractor shall provide a layout sketch of the project office area which must be located near the Clean Room of the Decontamination Unit if at all possible. The layout shall indicate location of the sign-in log, the job board with posted emergency procedures and the location of a workstation for the Owner. The following documents must be maintained at the site of a project for the abatement of asbestos for the duration of the project and retained by the contractor -- The contract or specifications for the project. -- The plan of the project and the estimated amount of asbestos involved in the project. -- The scheduled and actual dates for commencing and completing the project. If the actual date for completing the project differs from the date originally scheduled, a statement of the reasons for the difference must be included. -- Documentation of compliance with all regulatory requirements related to asbestos. -- Copies of all correspondence with regulatory agencies concerning the project, such as permits for building or demolition or notices of violations. -- The name and address of the authorized disposal facility to which the materials containing asbestos were taken, evidence of the amount of asbestos received for disposal and confirmation that the disposal was made pursuant to regulations adopted by the State Environmental Commission. -- The method by which samples of the air were tested during the abatement process, test results, name and license number of the consultant hired to perform the sampling, and name of the laboratory employed to analyze the testing. Page 5 of 13

6 -- A complete list of the names of abatement workers, supervisors and other employees or agents participating in the project. The Contractor shall provide a report on his staff organization, including licensure, individual experience, training and the chain of command to be utilized on the worksite. -- A description of unplanned releases of asbestos and accidents which occur at the work site. -- A log containing the names of persons who entered and exited the containment area and the times of their exit and entry. - The Contractor shall provide a description of respirators, protective clothing, and Personal protective Equipment (PPE) to be provided by the Contractor to his employees and all visitors to the work site. The description shall include brand names and specifications. - The Contractor shall also provide the step-by-step procedure he will employ and enforce for all individuals to enter and exit the wash area through the decontamination facility. Decontamination procedures for tools and equipment shall also be provided. 2.5 ASBESTOS CONTRACTOR INSURANCE Comprehensive General Liability Insurance: Contractor shall purchase and maintain during the course of this agreement Comprehensive General Liability Insurance which is occurrence basic including coverage for: Premises - operations Products - completed operations Blanket Contractual Broad form property damage Independent Contractors Automobile liability Personal injury Asbestos risks Limits for said insurance policies shall be for amounts of not less than those set forth below. GENERAL $2,000,000 PRODUCTS-COMP/OP $1,000,000 PERSONAL & ADV INJURY $1,000,000 EACH OCCURRENCE $1,000,000 All insurance required under this specification shall be equal to or exceed an A, AA, or AAA rating as listed in Best's Insurance Guide's latest edition. Page 6 of 13

7 In the event that asbestos risks are excluded from the Comprehensive General Liability, the Contractor must provide an additional policy insuring asbestos abatement liability that does not exclude asbestos abatement, asbestos disease or transportation to an Environmental Protection Agency (EPA) approved landfill, with limits of not less than One Million Dollars ($1,000,000.00) per occurrence. Insurance shall be occurrence basic. University of Nevada, Reno and their allied entities shall be named as additionally insured under this policy. With respect to the liability of any such additional insured arising out of this work for that insured by the Asbestos Abatement Contractor or for the Asbestos Abatement Contractor, this insurance is primary. 2.6 UTILITIES It is the responsibility of the Contractor to negotiate with the Owner for the use of water and to provide transportation of the water and the utilities for construction purposes, including but not limited to, electrical power, gas, telephone and sanitary facilities. The Contractor shall pay all costs involved in securing such utilities. 2.7 POST-ABATEMENT SUBMITTAL Upon completion of the work, and prior to the project being considered complete, the Contractor will prepare a report and submit it to the Owner. The report will contain: - A copy of all notifications to or permits received from Federal, State and local agencies for this project. - A copy of the signed waste manifests indicating the place, time and exact quantity of asbestos, received by an approved landfill. - A description of all problems encountered during the work. - A copy of the log maintained at the job site throughout the work containing the names of persons who entered and exited the containment area and the times of their exit and entry. A list of location and quantity of asbestos containing material not removed from the work area. - A copy of the log for any air monitoring performed by the Contractor, and the lab s analysis, including the location and credentials of the laboratory performing the analysis. - The name, title, and signature of the person who prepared the report. The Contractor will certify in writing that the work has been completed in accordance with the job scope given by the UNR Project Coordinator. The Post-Abatement Submittal will provide verification documentation that the project has been completed in accordance with the Contract Documents, and the Submittal shall be provided to, and approved by, the Owner as a project requirement prior to processing any final or phase completion pay request. Page 7 of 13

8 PART 3 TECHNICAL SPECIFICATIONS 3.1 PERSONAL PROTECTIVE EQUIPMENT (PPE) Contractor shall provide all workers with PPE in strict conformance with the OSHA Asbestos Construction Regulation (29 CFR ) requirements. Authorized visitors or inspectors must have fit tested PPE before being granted access to the abatement work area. 3.2 DECONTAMINATION SYSTEM AND WASTE LOAD-OUT Prior to beginning any pre-cleaning activities, Contractor shall construct a worker decontamination enclosure system connected to the existing work area. OSHA Class I abatement area decontamination enclosures will include the following features: An equipment or dirty room with two doorways, one to the work area and one to the decontamination room. A decontamination room with two doorways, one to the equipment room and one to the airlock/clean room. The decontamination room shall contain at least one shower with hot and cold water. Careful attention shall be paid to the shower enclosure to ensure against any leaking and the shower s water source should be disconnected and turned off at the end of each shift. Soap and shampoo will be available in the shower room at all times. Clean and dry towels will be available for employees and any Owner authorized visitors and personnel. A three-stage water filtration system will be employed prior to release of shower water into the local sewage system. An airlock/clean room with one doorway into the shower room and one to the outside area. OSHA Class II abatement area decontamination enclosures will include the following features: An equipment or dirty room with two doorways, one to the work area and one to the clean room. A decontamination room with one doorway into the dirty room and one to the outside area. Wash water, clean and dry towels will be available in this room for employees and any Owner authorized visitors and personnel. A three-stage water filtration system will be employed prior to release of water into the local sewage system. The contractor shall ensure employees enter and exit the regulated area through the decontamination area. Waste load-out shall take place through a two-stage waste load-out enclosure system constructed prior to waste load-out at the end of the abatement project or at the end of daily work. No gross abatement shall be performed while load-out is taking place. If the Contractor requests to use the worker decontamination facility for waste load-out, approval will be based on a no impact judgment on the protection to facilities or the final project provided to the Owner. Page 8 of 13

9 Bags of ACM will be wet wiped, removing all visible material from the exterior of the bags outside of the dirty room. Each bag will then be passed into the dirty room where it will be bagged again with a bag from the decontamination room. Load-out of the bag can then take place, after the bag is inspected to insure no contamination has taken place. Evacuation of excess air by HEPA vacuum is recommended. The waste transfer unit shall be fully lined (except ceiling) with one layer of 6-mil poly. The Contractor shall test the unit leak-tight and lockable. 3.3 ASBESTOS REMOVAL WORK SHALL NOT COMMENCE UNTIL: Arrangements have been made for disposal of waste at an EPA approved dumpsite. Arrangements have been made for containing and/or disposal of wastewater resulting from showering and other abatement activities. Containment, decontamination enclosure system, and waste load-out area are appropriately constructed and approved by the University EH&S Department. Tools, equipment and material waste receptacles are on-site. Suitable barricades and warning signs are established to restrict access to the work area to abatement associated personnel only. All other preparatory steps have been taken and applicable notices posted, and permits are obtained. A visitor and employee log-in log-out system is in place at the job site. All persons entering the site will be required to sign in and sign out. Sufficient differential pressure is established inside containment per Technical Specifications. A minimum of 0.02 column inches of water pressure differential, relative to outside pressure, shall be maintained within the Negative Pressure Enclosure (NPE) as evidenced by manometric measurements for all class I containments. A formal pre-abatement safety and procedure meeting has been held at the site with the University EH&S Department and Contractor's employees present. At this time the Contractor's final abatement plan must be submitted for each abatement area. Written notice to proceed has been given by Owner acknowledging that items above have been accomplished 3.4 MAINTENANCE OF ENCLOSURE SYSTEMS Ensure that barriers and plastic linings are effectively sealed and taped. Repair damaged barriers and remedy defects immediately upon discovery. Visually inspect enclosures and differential pressure units at the beginning of each work period or shift. Details of the inspections are to be included in the Contractor s daily log. Page 9 of 13

10 Use smoke methods to test effectiveness of barriers and the differential pressure containment at each shift, per OSHA regulatory requirements. 3.5 PROHIBITED PRACTICES No high speed abrasive saws without HEPA filters. No compressed air. No dry sweeping, shoveling or other dry clean-up. 3.6 CONTAINMENT CLEARANCE Removal and detail cleaning work will be considered complete when all surfaces inside containment areas have no visible debris or asbestos residue and have passed final clearance visual inspection by the Owner's Representative. The inner poly wall and floor shall be removed after the visual inspection is approved. Any contamination that penetrated the inner poly layer shall be thoroughly decontaminated and cleaned. If the outer poly layer was punctured or material leaked through, then the outer poly shall be removed in the contaminated areas and all contaminated materials cleaned or removed as contaminated materials. Aggressive air samples will be taken for clearance after a visual inspection has been passed. The Contractor will be allowed two visual inspections, and if work is still required after two inspections the Contractor shall pay for any costs associated with the additional inspections. All removals of friable ACM greater than ten square feet shall have aggressive air clearance by a third party consultant per the Nevada Administrative Code. Phase Contract Microscopy (PCM) air clearance testing will be performed by the Owner's Representative collecting a containment size appropriate number of samples inside the work area each with an air volume of at least 1200 liters taken at 10 liters per minute or less. The samples will be analyzed by PCM National Institute of Occupational Safety and Health (NIOSH) Method Any alternate sampling method shall be approved in advance by University EH&S. PCM clearance will be achieved if the average of all five inside sample results are equal to or below 0.01 fibers/cc. If clearance samples fail, the Contractor is responsible for all subsequent consulting and testing costs until the clearance is achieved. The Contractor shall remedy the situation that caused the failure, i.e., filter outside dirty air, re-clean inside surfaces or other, and then the Owner's Representative shall retest the containment area. Once the Visual Inspection and PCM Air Clearance is achieved encapsulation can occur. After encapsulation dries and passes inspection the Contractor shall remove all barriers and equipment. 3.7 DISPOSAL As the work progresses, and to prevent exceeding available dumpster storage capacity on site, remove asbestos waste and dispose of at an EPA approved disposal site in accordance with the requirements of the disposal authority. Submit documentation regarding disposal to the Owner. All ACM and asbestos contaminated material shall be double bagged (or wrapped) in 6-mil bags. ACM shall be wet/damp inside of collection bags. Bags shall not be dropped or handled roughly. If chutes are used, chute angle shall be sufficient to prevent breakage. All bags shall Page 10 of 13

11 be labeled per OSHA and have proper generator labels and information per EPA National Emissions Standards for Hazardous Air Pollutants (NESHAP). All ACM or asbestos contaminated material shall be damp when delivered to the disposal site. All ACM containers which also contain metal or other sharp objects shall be protected from punctures by placing in fiber drums or approved alternative. Sealed plastic bags may be dumped into the burial site unless the bags have been broken or damaged. Damaged bags shall be sealed by placing them in another properly labeled 6-mil bag. Each load must be accompanied by a Uniform Waste Manifest or equivalent and any other certificate required by state or local agencies. Copies of the Waste Manifest shall be provided to the Owner. The Contractor shall be responsible for the safe handling and transportation of all waste generated by this contract to the designated waste disposal site. The Contractor shall bear all costs for all claims, damages, losses and expenses against the Owner, Consultants or the Owner's representatives, including but not limited to attorney's fees arising out of or resulting from spills en-route to the waste disposal site. 3.8 RESTORATION WORK Damaged areas will be repaired or replaced to the satisfaction of the Owner. Any ground areas that may become contaminated with asbestos shall be decontaminated at the Contractor's expense. Decontamination procedures shall require full containment procedures. Removal of soil to a depth of four (4) inches, which shall be disposed of as asbestos waste. All other surfaces shall be free from dust, debris, and contamination. The Contractor shall encapsulate all decontaminated surfaces. 3.9 ASBESTOS ABATEMENT ADDITIONAL REQUIREMENTS A. Containment Full containment shall be established for all work (except glove bag or glove box procedures). Completion of full containment shall include the establishment of critical barriers over grilles, vents or any other penetrations, mechanical and electrical equipment, windows and doors. Critical barriers shall be installed on HVAC system ducting passing through the work area to other building areas. Where ducts exist at the perimeter of containment and interior ducting is to be removed, the remaining duct at the perimeter shall be capped with solid plywood or sheet metal barriers, caulking and any other material necessary to achieve an airtight seal. The airtight seals shall be maintained until clearance is achieved in the work area. The continued use of an adequate number of Differential Pressure Units (DPU) is also required. Air from the work area shall be continuously exhausted, through HEPA Page 11 of 13

12 filtration, to the building exterior via ducting secured by plywood window inserts. The Contractor shall remove exterior windows as necessary to install plywood inserts. Removed window areas shall be boarded up upon removal of containment. DPUs shall be installed immediately at the start of the work and operated continuously thereafter until final clearance is obtained. The Contractor acknowledges that it is his responsibility to install critical barriers and seals, smoke test all barriers daily, and immediately repair any leaks or breeches in these seals to the satisfaction of the Owner or Owner's Representative. The Contractor shall provide additional moveable DPUs inside containment, which shall be located in each active work area during all preparation and abatement work. During above ceiling critical barrier installation, DPU intakes shall be located in close proximity to work with flexible intake ducting. B. Decontamination and Waste Load-out Units Three-stage or two-stage decontamination and waste load-out units shall be constructed with rigid framing where they are exposed to the public. Surfaces exposed to the public or exterior building shall be 1/2-inch thick plywood. Shop drawings of each unit, including connection of shower and drainage filter for contaminated water, shall be made available to the Owner or Owner's representative. C. Electrical The Contractor is responsible for securing the electrical service necessary for completion of abatement activities. All electrical work and materials shall be installed in accordance with the national electric code and all other applicable codes. The Contractor shall retain the services of a licensed electrician who shall be responsible for identification, coordination, installation and maintenance of temporary ground-fault protected electrical power to equipment and circuits inside the work area. The Contractor shall supply power for the Owner's Representative, as necessary, for area and clearance air monitoring. D. Safety/Emergency Exits Emergency exits shall be clearly marked in work areas. Emergency flashlights and signal horns shall be located within containment areas. The Contractor shall provide daily project safety meetings on-site. E. Other Requirements A "Job Board", with SDS, emergency numbers (24 hours), safety procedures, air monitoring results, and DOP test certifications for DPUs and HEPA vacuums, shall be conspicuously placed within the near vicinity of containment areas, as directed by the Owner or Owner's representative. The Contractor shall post perimeter barriers around staging areas with signage indicating, CONSTRUCTION AREA KEEP OUT, and post containment entrances and waste containers as required by OSHA. Page 12 of 13

13 The Contractor shall have a responsible employee on duty at all times outside of the containment during abatement work. END OF SPECIFICATION Page 13 of 13

Asbestos Abatement Standard Procedures Indoor Environment Group, Inc.

Asbestos Abatement Standard Procedures Indoor Environment Group, Inc. The following work procedures are specified on all full containment asbestos abatement projects that we design. A. Preliminary Air Sampling: Many buildings contain background fiber levels prior to, or

More information

CLASS I AND II ABATEMENT PROJECT SUBMITTALS

CLASS I AND II ABATEMENT PROJECT SUBMITTALS 5.1 Pre-Work Submittals CLASS I AND II ABATEMENT PROJECT SUBMITTALS Abatement contractors shall submit the following in a bound notebook to AU or our designated representative at the mandatory pre-construction

More information

SECTION ASBESTOS CONTAINING MATERIALS REMEDIATION

SECTION ASBESTOS CONTAINING MATERIALS REMEDIATION SECTION 13280 ASBESTOS CONTAINING MATERIALS REMEDIATION PART 1 GENERAL 1.1 SECTION INCLUDES A. Furnishing all labor, materials, equipment, and transportation necessary for properly and safely removing,

More information

A. Illinois Asbestos Abatement Act, as amended through Public Act , effective July 14, 1995.

A. Illinois Asbestos Abatement Act, as amended through Public Act , effective July 14, 1995. April 2012, rev. 00 02 8213 Asbestos Abatement 1. General 1.01 Summary of Work A. Contractor 1.02 Definitions 1. The Contractor shall provide removal and proper disposal of asbestos containing materials.

More information

VERTEX Corporate Headquarters 400 Libbey Parkway Weymouth, MA p: f:

VERTEX Corporate Headquarters 400 Libbey Parkway Weymouth, MA p: f: VERTEX Corporate Headquarters 400 Libbey Parkway Weymouth, MA 02189 www.vertexeng.com p: 781.952.6000 f: 781.335.3543 EZRA BAKER ELEMENTARY SCHOOL/GYMNASIUM ASBESTOS ABATEMENT WORK PLAN ASBESTOS CONTAINING

More information

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Materials

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Materials Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Materials Revised November 21, 2013 Application Code of Practice Where asbestos is present or believed to be present in a workplace

More information

DIVISION 02 EXISTING CONDITIONS 2010 Edition, Published January 1, 2010; Document Revision Date: February 7, 2017

DIVISION 02 EXISTING CONDITIONS 2010 Edition, Published January 1, 2010; Document Revision Date: February 7, 2017 2010 Edition, Published January 1, 2010; Document Revision Date: February 7, 2017 02 00 00. EXISTING CONDITIONS 02 30 00. SUBSURFACE INVESTIGATION.1 Architect/Engineer RESPONSIBILITIES: The Architect/Engineer

More information

Work Plan dated February 17, Prepared by Axiom Partners, Inc. Stephen E. Minassian Massachusetts Asbestos Designer License #AD051928

Work Plan dated February 17, Prepared by Axiom Partners, Inc. Stephen E. Minassian Massachusetts Asbestos Designer License #AD051928 ABATEMENT WORK PLAN FOR EMERGENCY ASBESTOS ABATEMENT PROJECT CONSENTINO MIDDLE SCHOOL 685 WASHINGTON STREET HAVERHILL, MASSACHUSETTS Work Plan dated February 17, 2016 Prepared by Axiom Partners, Inc. Stephen

More information

ATTACHMENT A RFP # BH ASBESTOS ABATEMENT REQUIREMENTS

ATTACHMENT A RFP # BH ASBESTOS ABATEMENT REQUIREMENTS 1. DESCRIPTION OF WORK: ATTACHMENT A RFP # 024-0-2016BH ASBESTOS ABATEMENT REQUIREMENTS The work includes pre-cleaning, repair and/or removal and disposal of friable and non-friable asbestos containing

More information

In general, the management plan development process consisted of:

In general, the management plan development process consisted of: NWASCO SCHOOL DISTRICT #21 ASBESTOS MANAGEMENT PLAN PART I: GENERAL PROVISIONS OF THE MANAGEMENT PLAN 1.0 INTRODUCTION This Asbestos Management Plan was developed in accordance with the United States Department

More information

Project 6668 Second beach Concession-Stanley Park Drive,Vancouver, BC Division 02080

Project 6668 Second beach Concession-Stanley Park Drive,Vancouver, BC Division 02080 PART 1 GENERAL 1.0 Instructions To Bidders Hazardous Materials Contractors are responsible for the information as provided in the City of Vancouver Invitation to Tender including all available documents,

More information

Certification Number: NAT Lead Renovation, Repair and Painting Program

Certification Number: NAT Lead Renovation, Repair and Painting Program Certification Number: NAT-117534-2 Lead Renovation, Repair and Painting Program August 2018 Lead Renovation, Repair and Painting Program TABLE of CONTENTS I. Purpose II. Risk Identification III. Responsibilities

More information

1.1 SUMMARY.1 Comply with requirements of this Section when performing the following work:

1.1 SUMMARY.1 Comply with requirements of this Section when performing the following work: 125 Syndicate Avenue, Thunder Bay, Ontario Page 1 of 5 Part 1 General 1.1 SUMMARY.1 Comply with requirements of this Section when performing the following work:.1 Removing asbestos-containing transite

More information

Work Plan for Window Removal and Remediation Rooms: 200 Wing classrooms, Cafeteria and Kitchen Thomas Prince School Princeton, Massachusetts

Work Plan for Window Removal and Remediation Rooms: 200 Wing classrooms, Cafeteria and Kitchen Thomas Prince School Princeton, Massachusetts 1) Introduction Work Plan for Window Removal and Remediation Rooms: 200 Wing classrooms, Cafeteria and Kitchen Thomas Prince School Princeton, Massachusetts Triumvirate Environmental Inc. (TEI) shall perform

More information

A. Prior to commencement of any work, make a complete inspection of all of the facilities listed in this specification

A. Prior to commencement of any work, make a complete inspection of all of the facilities listed in this specification SECTION 028200 - ABESTOS ABATEMENT PART 1 - GENERAL 1.1 SCOPE OF WORK A. The following asbestos-containing materials is known to be present on the First and Second Floor classrooms of the North Wing of

More information

NAVSEA STANDARD ITEM. 1.1 Title: Asbestos-Containing Material (ACM); control

NAVSEA STANDARD ITEM. 1.1 Title: Asbestos-Containing Material (ACM); control NAVSEA STANDARD ITEM ITEM NO: 009-10 DATE: 18 NOV 2016 CATEGORY: I 1. SCOPE: 1.1 Title: Asbestos-Containing Material (ACM); control 2. REFERENCES: 2.1 29 CFR 1915.1001, Occupational Safety and Health Standards

More information

AUBURN UNIVERSITY RISK MANAGEMENT & SAFETY

AUBURN UNIVERSITY RISK MANAGEMENT & SAFETY AUBURN UNIVERSITY RISK MANAGEMENT & SAFETY ASBESTOS CONTROL PROGRAM September 22, 2006 Table of Contents 1.0 Introduction... 4 2.0 Purpose and Applicability... 4 3.0 Roles and Responsibilities... 5 3.1

More information

SECTION POLYCHLORINATED BIPHENYLS (PCB) REMOVAL

SECTION POLYCHLORINATED BIPHENYLS (PCB) REMOVAL SECTION 18200 POLYCHLORINATED BIPHENYLS (PCB) REMOVAL PART 1 GENERAL 1.01 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division

More information

BRIGHAM YOUNG UNIVERSITY IDAHO ENVIRONMENTAL, HEALTH & SAFETY SAFETY DEPARTMENT ASBESTOS MANAGEMENT PROGRAM EH-006-R02

BRIGHAM YOUNG UNIVERSITY IDAHO ENVIRONMENTAL, HEALTH & SAFETY SAFETY DEPARTMENT ASBESTOS MANAGEMENT PROGRAM EH-006-R02 BRIGHAM YOUNG UNIVERSITY IDAHO ENVIRONMENTAL, HEALTH & SAFETY SAFETY DEPARTMENT ASBESTOS MANAGEMENT PROGRAM EH-006-R02 Department Title: Safety Department Page: 2 Department Title: Safety Department Page:

More information

These procedures are to be followed by all persons required to perform the following work:

These procedures are to be followed by all persons required to perform the following work: These procedures are to be followed by all persons required to perform the following work: Entry into any ceiling space above which an asbestos-containing fireproofing or thermal insulation is present.

More information

PROPOSED PILOT PROGRAM WORK PLAN FOR THE REMOVAL OF ALUMINUM COLUMN COVERS AND FASCIA WITH NON-FRIABLE ACM CAULKING MATERIAL

PROPOSED PILOT PROGRAM WORK PLAN FOR THE REMOVAL OF ALUMINUM COLUMN COVERS AND FASCIA WITH NON-FRIABLE ACM CAULKING MATERIAL PROPOSED PILOT PROGRAM WORK PLAN FOR THE REMOVAL OF ALUMINUM COLUMN COVERS AND FASCIA WITH NON-FRIABLE ACM CAULKING MATERIAL At 130 Liberty Street New York, New York Lower Manhattan Development Corporation

More information

LEAD HAZARD CONTROL PROGRAM

LEAD HAZARD CONTROL PROGRAM LEAD HAZARD CONTROL PROGRAM Supervisor s Manual Prepared by Environmental Health and Safety Services Occupational Safety Programs GLOSSARY Abatement or Deleading CFR Control Measure Encapsulation EPA HEPA

More information

Project 6668 Kerrisdale Senoirs Centre-5851 West Boulevard,Vancouver, BC Division 02080

Project 6668 Kerrisdale Senoirs Centre-5851 West Boulevard,Vancouver, BC Division 02080 PART 1 GENERAL 1.0 Instructions To Bidders Hazardous Materials Contractors are responsible for the information as provided in the Invitation to Tender including all available documents, meeting minutes,

More information

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT COMPLIANCE DEPARTMENT COM 2065

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT COMPLIANCE DEPARTMENT COM 2065 SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT COMPLIANCE DEPARTMENT COM 2065 APPROVED: SIGNED DATE: March 8, 2007 Jon Adams Director of Compliance TITLE: SUBJECT: RULE 4002 NATIONAL EMISSION

More information

NORTH DAKOTA DEPARTMENT OF TRANSPORTATION REQUEST FOR PROPOSAL ASBESTOS AIR MONITORING SERVICES

NORTH DAKOTA DEPARTMENT OF TRANSPORTATION REQUEST FOR PROPOSAL ASBESTOS AIR MONITORING SERVICES NORTH DAKOTA DEPARTMENT OF TRANSPORTATION REQUEST FOR PROPOSAL ASBESTOS AIR MONITORING SERVICES September 12, 2008 INTRODUCTION North Dakota Department of Transportation (NDDOT) is seeking an asbestos

More information

DUQUESNE UNIVERSITY ASBESTOS OPERATIONS & MAINTENANCE PROGRAM

DUQUESNE UNIVERSITY ASBESTOS OPERATIONS & MAINTENANCE PROGRAM DUQUESNE UNIVERSITY ASBESTOS OPERATIONS & MAINTENANCE PROGRAM Revised January 2017 Prepared by: Environmental Health and Safety Department TABLE OF CONTENTS Page Introduction 1 Scope 1 Policy Statement

More information

Site Specific Hazardous Material Abatement Work Plan

Site Specific Hazardous Material Abatement Work Plan Site Specific Hazardous Material Abatement Work Plan Jobsite Location: Pier 31 Building and Roof Repair Project Port of San Francisco San Francisco, California Prepared By: North Tower Environmental, Inc.

More information

Post Abatement Project Report - Sample Draft Form:

Post Abatement Project Report - Sample Draft Form: Post Abatement Project Report - Sample Draft Form: 3701-3215 (B) (B) Each lead abatement contractor or lead abatement project designer shall issue a report for each lead abatement project performed. The

More information

EPA s New Renovation, Repair and Painting Rule

EPA s New Renovation, Repair and Painting Rule When is Compliance with the EPA Renovation, Repair, and Painting Rule Required? Scope of Rule: Renovation, repair and painting activities on target housing or child-occupied facility built before 1978

More information

SECTION ADDENDA

SECTION ADDENDA SECTION 00 91 03 ADDENDA ADDENDUM NO. 2 June 14, 2017 RE: Cana Island Light Station Phase 2 Baileys Harbor, WI RA 1372.A FROM: TO: River Architects, Inc. 740 7 th Street North La Crosse, Wisconsin 54601

More information

Asbestos Management Plan. Program originated: 02/2000 Last updated: 6/2015. Wendel Reece University Safety Manager

Asbestos Management Plan. Program originated: 02/2000 Last updated: 6/2015. Wendel Reece University Safety Manager Asbestos Management Plan Program originated: 02/2000 Last updated: 6/2015 Wendel Reece University Safety Manager TABLE OF CONTENTS I. Introduction II. Purpose III. Operations and Maintenance Asbestos Related

More information

GENERIC ASBESTOS OPERATION AND MAINTENANCE (O&M) PLAN

GENERIC ASBESTOS OPERATION AND MAINTENANCE (O&M) PLAN Environmental Sciences Corporation 25 Years of Environmental Excellence National Environmental Assessment, Compliance, Industrial Hygiene, UST/AST, Construction Management and Engineering Services GENERIC

More information

UI Procedures for Asbestos Management

UI Procedures for Asbestos Management UI Procedures for Asbestos Management The University of Iowa Rev.10/22/08, 10/15/09 These procedures apply to employees and contractors involving the identification, work on, removal, or repair of asbestos-containing

More information

Project Monitoring & Air Sampling

Project Monitoring & Air Sampling Project Monitoring & Air Sampling 1. Qualifications of Air Sampling Personnel. The project air sampling shall be conducted by an asbestos project air sampling technician who has been trained in the selected

More information

FRIABLE AND NON-FRIABLE ASBESTOS REMOVAL. Provisions of the General Conditions and Special Conditions are part of this Division.

FRIABLE AND NON-FRIABLE ASBESTOS REMOVAL. Provisions of the General Conditions and Special Conditions are part of this Division. SECTION 02080 FRIABLE AND NON-FRIABLE ASBESTOS REMOVAL PART 1 - GENERAL Provisions of the General Conditions and Special Conditions are part of this Division. 1.1 SCOPE OF WORK 1. General: The work specified

More information

SECTION 2080 ASBESTOS ABATEMENT

SECTION 2080 ASBESTOS ABATEMENT SECTION 2080 ASBESTOS ABATEMENT PART 1 - GENERAL 1.01 SECTION INCLUDES A. Specification for the abatement of identified asbestos-containing materials (ACMs) and asbestos-containing construction materials

More information

SECTION PCB REMEDIATION OF BUILDING MATERIALS

SECTION PCB REMEDIATION OF BUILDING MATERIALS SECTION 020720 PCB REMEDIATION OF BUILDING MATERIALS PART 1 - GENERAL 1.01 GENERAL PROVISIONS A. Attention is directed to the Contract and General Conditions and all Sections within Division 1 - General

More information

Anticipated ICR 56 Revisions. Relating to Fire/Life Safety & Other Significant Issues

Anticipated ICR 56 Revisions. Relating to Fire/Life Safety & Other Significant Issues Anticipated ICR 56 Revisions Relating to Fire/Life Safety & Other Significant Issues Introduction Anticipated Timeframe for ICR 56 Revisions ICR 56 Fire & Life Safety Issues Cleanup of uncontrolled asbestos

More information

ADDENDUM No. 1 July 11, 2013 ASBESTOS ABATEMENT SPECIFICATIONS. Crawlspace Abatement and New Beginnings Academy

ADDENDUM No. 1 July 11, 2013 ASBESTOS ABATEMENT SPECIFICATIONS. Crawlspace Abatement and New Beginnings Academy BID No. 13.01 ADDENDUM No. 1 July 11, 2013 ASBESTOS ABATEMENT SPECIFICATIONS Crawlspace Abatement and Reinsulation @ New Beginnings Academy Owner NEW BEGINNINGS ACADEMY 211 East Michigan Avenue Ypsilanti,

More information

EPA s Lead Program Rule At-A-Glance

EPA s Lead Program Rule At-A-Glance EPA s Lead Program Rule At-A-Glance FLOW CHART 1: Do the Requirements Apply to the Renovation? If you will be getting paid to do work that disturbs painted surfaces in a pre-1978 home, apartment building,

More information

NAVSEA STANDARD ITEM. 1.1 Title: Asbestos-Containing Material (ACM); control

NAVSEA STANDARD ITEM. 1.1 Title: Asbestos-Containing Material (ACM); control NAVSEA STANDARD ITEM ITEM NO: 009-10 DATE: 30 APR 2018 CATEGORY: I 1. SCOPE: 1.1 Title: Asbestos-Containing Material (ACM); control 2. REFERENCES: 2.1 29 CFR 1915.1001, Occupational Safety and Health Standards

More information

DUQUESNE UNIVERSITY ASBESTOS MANAGEMENT PROGRAM

DUQUESNE UNIVERSITY ASBESTOS MANAGEMENT PROGRAM DUQUESNE UNIVERSITY ASBESTOS MANAGEMENT PROGRAM Revised January 2017 Prepared by: Environmental Health and Safety Department TABLE OF CONTENTS Page Purpose 1 Scope 2 Definitions 2 Responsibilities 3 Hazard

More information

WESTERN CONNECTICUT STATE UNIVERSITY ASBESTOS ABATEMENT PROCEDURE E-101

WESTERN CONNECTICUT STATE UNIVERSITY ASBESTOS ABATEMENT PROCEDURE E-101 WESTERN CONNECTICUT STATE UNIVERSITY ASBESTOS ABATEMENT PROCEDURE E-101 Issued 6/1/95 Revised 11/08/2004; 3/6/06 Please direct any questions or comments about the applicability of this document to Luigi

More information

Prepared by: Atlantic Testing Laboratories, Limited 22 Corporate Drive Clifton Park, New York 12065

Prepared by: Atlantic Testing Laboratories, Limited 22 Corporate Drive Clifton Park, New York 12065 ASBESTOS REMOVAL DESIGN FOR PIPE THERMAL SYSTEM INSULATION AND FLOOR TILE AND ASSOCIATED MASTIC LOCKER ROOMS CAPITAL DISTRICT TRANSPORTATION AUTHORITY ALBANY, NEW YORK Prepared for: 110 Watervliet Avenue

More information

Appendix B PROCEDURES FOR REMOVAL OF MOULD-CONTAMINATED MATERIALS

Appendix B PROCEDURES FOR REMOVAL OF MOULD-CONTAMINATED MATERIALS Appendix B PROCEDURES FOR REMOVAL OF MOULD-CONTAMINATED MATERIALS The following procedures are presented as a guide. Comprehensive site-specific technical specifications for the removal of mould-contaminated

More information

3. Asbestos Handling Program

3. Asbestos Handling Program 1.0 Introduction 3. Asbestos Handling Program This program will establish guidelines and procedures in the operations and maintenance of asbestos containing materials at PLU to protect all employees, contractors,

More information

Emergency Asbestos Abatement Project Monitoring September 21, 2013 Peebles Elementary School Bourne, Massachusetts

Emergency Asbestos Abatement Project Monitoring September 21, 2013 Peebles Elementary School Bourne, Massachusetts Emergency Asbestos Abatement Project Monitoring September 21, 2013 Peebles Elementary School Bourne, Massachusetts Bourne Public Schools Bourne, Massachusetts February 5, 2014 Fuss & O Neill EnviroScience,

More information

Asbestos Management Program

Asbestos Management Program Oct. 10/06 Oct 10/06 1/13 Table of Contents 1 INTRODUCTION...2 2 PURPOSE...2 3 SCOPE...2 4 ROLES & RESPONSIBILITIES...2 5 INVENTORY...6 6 ACCESS CONTROL...6 7 INSPECTION...6 8 CLASSIFICATIONS OF ASBESTOS

More information

Asbestos Consulting Radon Measurements Lead Assessments Indoor Air Quality Testing Mold Investigations. Project Number: Page 1 of 22

Asbestos Consulting Radon Measurements Lead Assessments Indoor Air Quality Testing Mold Investigations. Project Number: Page 1 of 22 Page 1 of 22 Asbestos Survey Project Summary Pursuant to your request; Environmental, Inc., has performed an Asbestos Building Survey on 8/13/2014 and limited to the above referenced location. The Interior/Exterior/Roof

More information

ASBESTOS ABATEMENT SPECIFICATIONS FOR GUNN MEMORIAL PUBLIC LIBRARY 161 MAIN STREET EAST YANCEYVILLE, NORTH CAROLINA ECS Project No.

ASBESTOS ABATEMENT SPECIFICATIONS FOR GUNN MEMORIAL PUBLIC LIBRARY 161 MAIN STREET EAST YANCEYVILLE, NORTH CAROLINA ECS Project No. ASBESTOS ABATEMENT SPECIFICATIONS FOR GUNN MEMORIAL PUBLIC LIBRARY 161 MAIN STREET EAST YANCEYVILLE, NORTH CAROLINA 27379 ECS Project No. 49:4798-A Prepared For: Caswell County 161 Main Street East Yanceyville,

More information

BASF Corporation Title: ASBESTOS HANDLING, REMOVAL AND DEMOLITION

BASF Corporation Title: ASBESTOS HANDLING, REMOVAL AND DEMOLITION Procedure No.: IH-6 Page: 1 of 16 Preparer: Owner: Approver: RECORD OF REVISIONS Date Details of Change 11/02/01 Added a Record of Revisions table. 08/14/08 Review of entire procedure. Deleted 4.3.3 and

More information

Section Asbestos Containment Procedures

Section Asbestos Containment Procedures Section Cover Page Section 02 82 05 2017-10-01 Use this Section where full containment will be required, or if a Contractor option, may be required, depending on the removal method(s) selected by the Contractor.

More information

Request for Proposals Westhill Gardens Asbestos Abatement The Housing Authority of the Town of Manchester February 23, 2017

Request for Proposals Westhill Gardens Asbestos Abatement The Housing Authority of the Town of Manchester February 23, 2017 Request for Proposals Westhill Gardens Asbestos Abatement The Housing Authority of the Town of Manchester February 23, 2017 Request for Proposals The Housing Authority of Manchester (MHA herein) is seeking

More information

Asbestos Management Program

Asbestos Management Program ENVIRONMENTAL HEALTH & SAFETY Reed College 3203 Southeast woodstock boulevard Portland, Oregon 97202-8199 Asbestos Management Program Effective Date: 6/16/2009 Revision Dates or Last Date: 2/2016 I. Purpose...

More information

UNIVERSITY OF COLORADO AT BOULDER

UNIVERSITY OF COLORADO AT BOULDER UNIVERSITY OF COLORADO AT BOULDER SPECIFICATION FOR INDUSTRIAL HYGIENE CONSULTING SERVICES ASBESTOS ABATEMENT PROJECTS IN FACILITIES FACILITY ASSESSMENTS- PROJECT SURVEILLANCE-AIR MONITORING PROCEDURES

More information

BARR & CLARK Independent Environmental Testing Asbestos Lead Mold Phase I ASBESTOS REMOVAL SPECIFICATIONS

BARR & CLARK Independent Environmental Testing Asbestos Lead Mold Phase I ASBESTOS REMOVAL SPECIFICATIONS BARR & CLARK Independent Environmental Testing Asbestos Lead Mold Phase I ASBESTOS REMOVAL SPECIFICATIONS OF 5 BUILDINGS 1400 E. MISSION BOULEVARD POMONA, CA PROJECT NO. 3009860 JUNE 23, 2017 Prepared

More information

Asbestos During Brake and Clutch Service Work Self Inspection Checklist

Asbestos During Brake and Clutch Service Work Self Inspection Checklist Optional Information Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Asbestos During Brake and Clutch Service Work Self Inspection Checklist Guidelines: This

More information

"ASBESTOS AWARENESS IN THE WORKPLACE"

ASBESTOS AWARENESS IN THE WORKPLACE MAJOR PROGRAM POINTS "ASBESTOS AWARENESS IN THE WORKPLACE" Training For THE OSHA ASBESTOS STANDARD Quality Safety and Health Products, for Today...and Tomorrow Outline of Major Points Covered in the "Asbestos

More information

University of Colorado at Boulder SOC Asbestos Abatement Specification TABLE OF CONTENTS

University of Colorado at Boulder SOC Asbestos Abatement Specification TABLE OF CONTENTS TABLE OF CONTENTS Asbestos Abatement Specification Pg. 2-3 Schedule of Asbestos-Containing Materials Pg. 3-5 Examination of Site Pg. 5 Work Under Other Contracts Pg. 5-6 Work Sequence Pg. 6 Asbestos-Containing

More information

SECTION ASBESTOS REMOVAL

SECTION ASBESTOS REMOVAL SECTION 02 82 00 ASBESTOS REMOVAL PART 1 GENERAL 1.01 SCOPE OF WORK A. This asbestos abatement Project will consist of the removal and disposal of asbestos containing materials (ACM), debris removal and

More information

Developed and Presented by: Wisconsin Healthcare Engineering Association

Developed and Presented by: Wisconsin Healthcare Engineering Association Infection Control Risk Assessment (ICRA) Developed and Presented by: Wisconsin Healthcare Engineering Association What is an ICRA? An Infection Control Risk Assessment is a tool devised to protect patients

More information

Asbestos Management Program

Asbestos Management Program Asbestos Management Program The University Of Iowa Environmental Health & Safety 122 Grand Avenue Court Iowa City, IA 52242-1000 Phone: 319-335-8501 Date Revised/Reviewed: 5/8/2018 Table of Contents 1.

More information

WASHINGTON DULLES INTERNATIONAL AIRPORT MAIN TERMINAL HISTORIC AIR TRAFFIC CONTROL TOWER EXTERIOR PRESERVATION, PHASE 1

WASHINGTON DULLES INTERNATIONAL AIRPORT MAIN TERMINAL HISTORIC AIR TRAFFIC CONTROL TOWER EXTERIOR PRESERVATION, PHASE 1 SPECIFICATIONS FOR WASHINGTON DULLES INTERNATIONAL AIRPORT MAIN TERMINAL HISTORIC AIR TRAFFIC CONTROL TOWER EXTERIOR PRESERVATION, PHASE 1 PART B CONTRACT DOCUMENTS Prepared for: METROPOLITAN WASINGTON

More information

TSI SAMPLE MANAGEMENT PLANNER INITIAL. Training Services International, Inc. Qualifications & Functions

TSI SAMPLE MANAGEMENT PLANNER INITIAL. Training Services International, Inc. Qualifications & Functions MANAGEMENT PLANNER INITIAL Asbestos Training Course Federal Edition Training Services International www.training.com What management planning qualifications exist? How do I become certified to perform

More information

1.1 SUMMARY.1 Comply with requirements of this Section when performing following work:

1.1 SUMMARY.1 Comply with requirements of this Section when performing following work: Page 1 of 6 Part 1 General 1.1 SUMMARY.1 Comply with requirements of this Section when performing following work:.1 Removing roofing materials that are suspected of containing asbestos using wet material

More information

Asbestos Awareness Program

Asbestos Awareness Program Safety Manual 1 of 9 Safety Manual Sect: 1.0 Purpose 2.0 Scope Rel. Date: Last Review: This program covers Ardent policy related to asbestos, either discovered or suspected in the workplace. Ardent recognizes

More information

INTRODUCTION TO THE PROGRAM

INTRODUCTION TO THE PROGRAM INTRODUCTION TO THE PROGRAM Structure and Organization Information in this program is presented in a definite order, so that employees will see the relationships between the various groups of information

More information

ASBESTOS DISPOSAL INFORMATION (Revised 07/15/18)

ASBESTOS DISPOSAL INFORMATION (Revised 07/15/18) Fairbanks North Star Borough Division 455 Sanduri Street Fairbanks, Alaska 99701 (907) 459-1482 FAX 459-1017 ASBESTOS DISPOSAL INFORMATION (Revised 07/15/18) The FNSB Division accepts asbestos on a scheduled

More information

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 8

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 8 Safety Manual Page 1 of 8 1. Purpose This policy assists in protecting USPL workers from exposure to lead and to gain compliance with state and federal regulations. 2. Scope The OSHA requirements and this

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 02 82 00 Asbestos Remediation I. PROJECT COORDINATION A. General 1. All Asbestos Abatement Contractors will be licensed general contractors in either the specialty interior, building, unclassified or

More information

Standard Operating Procedures for the Control of Lead During Building Maintenance and Construction Activities. Type 1 Lead Operations

Standard Operating Procedures for the Control of Lead During Building Maintenance and Construction Activities. Type 1 Lead Operations Standard Operating Procedures for the Control of Lead During Building Maintenance and Construction Activities Type 1 Lead Operations Lead is a heavy metal that has and continues to be widely used in industry

More information

REMOVAL AND DISPOSAL OF MATERIALS CONTAINING LEAD. A. General provisions of the Contract, including General and Supplementary Conditions.

REMOVAL AND DISPOSAL OF MATERIALS CONTAINING LEAD. A. General provisions of the Contract, including General and Supplementary Conditions. 028333 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions. B. Contract Drawings. 1.2 SUMMARY A. The lead removal work is in support

More information

Asbestos Management Policy University of Wisconsin-Platteville Reviewed 4/2016

Asbestos Management Policy University of Wisconsin-Platteville Reviewed 4/2016 Asbestos Management Policy University of Wisconsin-Platteville Reviewed 4/2016 1.0 Purpose This written program is intended to comply with both state and federal asbestos regulations. Asbestos containing

More information

Chico State- Siskiyou Hall EXHIBIT B REQUIREMENTS FOR DISTURBANCE OF LEAD IN CONSTRUCTION TABLE OF CONTENTS

Chico State- Siskiyou Hall EXHIBIT B REQUIREMENTS FOR DISTURBANCE OF LEAD IN CONSTRUCTION TABLE OF CONTENTS Chico State- Siskiyou Hall EXHIBIT B REQUIREMENTS FOR DISTURBANCE OF LEAD IN CONSTRUCTION TABLE OF CONTENTS PART 1.0 GENERAL REQUIREMENTS.............................................. 1 1.1 Introduction.............................................................

More information

PROCEDURES FOR REMEDIATION OF FUNGI IN INDOOR ENVIRONMENTS LEVEL I:

PROCEDURES FOR REMEDIATION OF FUNGI IN INDOOR ENVIRONMENTS LEVEL I: OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY FACILITIES AND SERVICES PROCEDURES FOR REMEDIATION OF FUNGI IN INDOOR ENVIRONMENTS LEVEL I: SMALL ISOLATED AREA (less than 10sq. ft.) -- e.g. CEILING TILES AND

More information

KELSAY Environmental Consulting

KELSAY Environmental Consulting SPECIFICATIONS FOR FOR THE Eccles Elementary Flooring Remodel Project PREPARED FOR Canby School District Canby, Oregon PREPARED BY KELSAY Environmental Consulting CCB#196361 3693 SE Francis St. Portland,

More information

Adv. 3.2: Asbestos Abatement Rev

Adv. 3.2: Asbestos Abatement Rev ADVISORY NO. 3.2: ASBESTOS ABATEMENT TERMINOLOGY AND DEFINITIONS Abatement: Procedures to control fiber release from asbestos-containing materials, i.e., removal, encapsulation, or enclosure. Air Lock:

More information

Addendum No. 1. June 12, 2017 Renovation of Consuella Carter Music Hall Coahoma Community College

Addendum No. 1. June 12, 2017 Renovation of Consuella Carter Music Hall Coahoma Community College June 12, 2017 Renovation of Consuella Carter Music Hall Coahoma Community College Addendum No. 1 This Addendum forms part of the Contract Documents for the above referenced project. All other requirements

More information

October 1, Ted Sherman Saint Paul Public Schools 360 Colborne Street Saint Paul, MN Dear Ted,

October 1, Ted Sherman Saint Paul Public Schools 360 Colborne Street Saint Paul, MN Dear Ted, October 1, 2009 Ted Sherman Saint Paul Public Schools 360 Colborne Street Saint Paul, MN 55102 Dear Ted, Enclosed please find the Roosevelt Elementary School East Side Asbestos Removal and O & M Final

More information

September 29, Ted Sherman Saint Paul Public Schools 360 Colborne Street Saint Paul, MN Dear Ted,

September 29, Ted Sherman Saint Paul Public Schools 360 Colborne Street Saint Paul, MN Dear Ted, September 29, 2009 Ted Sherman Saint Paul Public Schools 360 Colborne Street Saint Paul, MN 55102 Dear Ted, Enclosed please find the Homecroft Elementary School West Side Asbestos Removal and O & M Final

More information

Assessment Completed by: Asbestos Inspections, LLC 4686 Pee Dee Highway Conway, South Carolina (843)

Assessment Completed by: Asbestos Inspections, LLC 4686 Pee Dee Highway Conway, South Carolina (843) ASBESTOS ABATEMENT PLAN 1814 PRINCE STREET Georgetown, South Carolina Asbestos Inspections, LLC Project # 2017-48 Performed in general accordance with SCDHEC Asbestos Regulation 61.86.1 Assessment Completed

More information

ASBESTOS ABATEMENT CONTRACTOR BID DOCUMENT AND SPECIFICATIONS

ASBESTOS ABATEMENT CONTRACTOR BID DOCUMENT AND SPECIFICATIONS ASBESTOS ABATEMENT CONTRACTOR BID DOCUMENT AND SPECIFICATIONS Highland Park Middle School HVAC Upgrade Project 7000 SW Wilson Avenue Beaverton, OR 97008 Prepared for: Beaverton School District 16550 SW

More information

TECHNICAL SPECIFICATIONS REMOVAL OF HAZARDOUS MATERIALS PROJECT NEON DEMOLITION PACKAGE B LAS VEGAS, NEVADA

TECHNICAL SPECIFICATIONS REMOVAL OF HAZARDOUS MATERIALS PROJECT NEON DEMOLITION PACKAGE B LAS VEGAS, NEVADA TECHNICAL SPECIFICATIONS REMOVAL OF HAZARDOUS MATERIALS PROJECT NEON DEMOLITION PACKAGE B LAS VEGAS, NEVADA Converse Project No.: 12-43224-01 Prepared For Nevada Department of Transportation 1263 South

More information

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 8

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 8 BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 8 1. Purpose This policy assists in protecting USPL workers from exposure to lead and to gain compliance with state and federal regulations.

More information

Addendum No. 2. (i) Issued January 23, 2018 REQUEST FOR PROPSALS FOR GENERAL CONTRACTOR. SHSU CJC AHU Replacement. RFP No.

Addendum No. 2. (i) Issued January 23, 2018 REQUEST FOR PROPSALS FOR GENERAL CONTRACTOR. SHSU CJC AHU Replacement. RFP No. Addendum No. 2 (i) Issued January 23, 2018 REQUEST FOR PROPSALS FOR GENERAL CONTRACTOR SHSU CJC AHU Replacement RFP No.: 753-17-95553H Notice to All Respondents: The following is Addendum No. 2 to the

More information

SOUTHEASTERN PENNSYLVANIA TRANSPORATION AUTHORITY ASBESTOS AND LEAD AIR MONITORING AND SAMPLING SERVICES SCOPE OF WORK

SOUTHEASTERN PENNSYLVANIA TRANSPORATION AUTHORITY ASBESTOS AND LEAD AIR MONITORING AND SAMPLING SERVICES SCOPE OF WORK SOUTHEASTERN PENNSYLVANIA TRANSPORATION AUTHORITY ASBESTOS AND LEAD AIR MONITORING AND SAMPLING SERVICES SCOPE OF WORK I. General Information: The Southeastern Pennsylvania Transportation Authority (SEPTA)

More information

BID SHEET EAST AND WEST TECHNOLOGY ASBESTOS ABATEMENT

BID SHEET EAST AND WEST TECHNOLOGY ASBESTOS ABATEMENT Renovations Asbestos Abatement BID SHEET EAST AND WEST TECHNOLOGY ASBESTOS ABATEMENT Asbestos Material Quantity Unit Price Bid Price Mud Compound Insulation 795 each Floor Tile 10,560 sf Lab Counter Tops

More information

ASBESTOS ABATEMENT CONTRACTOR BID DOCUMENT AND SPECIFICATION

ASBESTOS ABATEMENT CONTRACTOR BID DOCUMENT AND SPECIFICATION ASBESTOS ABATEMENT CONTRACTOR BID DOCUMENT AND SPECIFICATION Aloha High School Auto Tech Remodel Project 18550 SW Kinnaman Road Beaverton, Oregon 97078 Prepared for: Beaverton School District 16550 SW

More information

University of Toronto Asbestos Management Program PROCEDURAL CHECKLIST FOR TYPE 1 ASBESTOS ACTIVITIES

University of Toronto Asbestos Management Program PROCEDURAL CHECKLIST FOR TYPE 1 ASBESTOS ACTIVITIES University of Toronto Asbestos Management Program PROCEDURAL CHECKLIST FOR TYPE 1 ASBESTOS ACTIVITIES Project Description: Date Work Conducted: Completed by: (Name and Dept) NOTIFICATION/AWARENESS: 1.

More information

The City of Waltham. Invites Interested Parties To propose the best offer and or bid For the service or product herewith described:

The City of Waltham. Invites Interested Parties To propose the best offer and or bid For the service or product herewith described: The City of Waltham Invites Interested Parties To propose the best offer and or bid For the service or product herewith described: ASBESTOS REMOVAL AND HYGIENE SERVICES FOR CERTAIN AREAS OF THE FORMER

More information

Appendix F Asbestos Emission Control Plan (on CD-ROM)

Appendix F Asbestos Emission Control Plan (on CD-ROM) Appendix F Asbestos Emission Control Plan (on CD-ROM) rjmmmrmpv Asbestos Emission Control Plan MPCA VIC Project No. VP22480 Dakota County, Minnesota Prepared for the University of Minnesota November 14,

More information

LOWE S INSTALLER LRRP CHECKLIST FOR RENOVATIONS PERFORMED IN PRE-1978 HOUSING AND CHILD-OCCUPIED FACILITIES

LOWE S INSTALLER LRRP CHECKLIST FOR RENOVATIONS PERFORMED IN PRE-1978 HOUSING AND CHILD-OCCUPIED FACILITIES LOWE S INSTALLER LRRP CHECKLIST FOR RENOVATIONS THE PURPOSE OF THIS FORM IS TO DOCUMENT COMPLIANCE WITH THE U.S. ENVIRONMENTAL PROTECTION AGENCY S LEAD RENOVATION, REPAIR, AND PAINTING RULE ( RRP RULE

More information

ESTATES DEPARTMENT. Management of Asbestos Policy and Procedures Document. Rev 9

ESTATES DEPARTMENT. Management of Asbestos Policy and Procedures Document. Rev 9 ESTATES DEPARTMENT Management of Asbestos Policy and Procedures Document Rev 9 Contents SECTION 1: Estates Management of Asbestos Policy 1.1 Introduction 1.2 Policy Statement 1.3 Legal Requirements 1.4

More information

ASBESTOS ABATEMENT C.O.S. - WASTEWATER TREATMENT PLANT PAGE 1 of 10

ASBESTOS ABATEMENT C.O.S. - WASTEWATER TREATMENT PLANT PAGE 1 of 10 ASBESTOS ABATEMENT C.O.S. - WASTEWATER TREATMENT PLANT PAGE 1 of 10 1.0 GENERAL.1 SCOPE The City of Saskatoon intends and this specification covers the removal of Asbestos Containing Material from within

More information

Abatement Scope of Work and Project Requirements for Library Painting Project Bay Shore Library Bret Harte Library Dana Library Long Beach, California

Abatement Scope of Work and Project Requirements for Library Painting Project Bay Shore Library Bret Harte Library Dana Library Long Beach, California for Bay Shore Library Bret Harte Library Dana Library Background Information Site/Building Owner: City of Long Beach Site Contact: The City of Long Beach Public Works Department, 333 West Ocean Blvd. Long

More information

ASBESTOS SCIENCE TECHNOLOGIES, INC.

ASBESTOS SCIENCE TECHNOLOGIES, INC. ASBESTOS SCIENCE TECHNOLOGIES, INC. P.O. Box 505 Bangor, CA 95914 Phone (530) 518-0934 Email - astinc17@yahoo.com Report for Trinity Valley Elem. School Willow Creek, Ca. Mold Report - Rooms 12 through

More information

Asbestos and Lead Considerations in Construction Projects. Sean Purcer Senior Consultant Anthony Price Senior Consultant

Asbestos and Lead Considerations in Construction Projects. Sean Purcer Senior Consultant Anthony Price Senior Consultant Asbestos and Lead Considerations in Construction Projects Sean Purcer Senior Consultant Anthony Price Senior Consultant Who We Are History Founded in 1990 by Environmental, Health and Safety (EHS) managers

More information

Calvin College Asbestos Operations and Maintenance Plan

Calvin College Asbestos Operations and Maintenance Plan Calvin College Asbestos Operations and Maintenance Plan INTRODUCTION Calvin College s Asbestos Operations and Maintenance Plan has three primary objectives: 1) remove existing contamination and remove/repair

More information

Lead Safe Practices and Compliance

Lead Safe Practices and Compliance Lead Safe Practices and Compliance Purpose: The purpose of the Lead Policy is to ensure that activities (e.g. renovations, painting, demo, etc.) that could potentially involve disturbing or removal of

More information