1 Square and Rectangular Directional Diffusers Product Overview Price offers a complete line of square and rectangular directional diffusers for a velocity of. Models SMD / AMD This series of louvered face directional diffusers is available in steel (SMD) and aluminum (AMD) construction with a wide variety of air pattern core styles in square and rectangular neck styles. They can supply large volumes of air at low sound levels and pressure drops. Complete with a wide selection of frames for flush, T-bar and drop mounting, the SMD / AMD is the diffuser of choice for most architectural applications. Models SMDA / AMDA Matching the styling of the SMD / AMD line of diffusers, these are designed for field adjustment from horizontal to vertical air pattern and are available in steel (SMDA) or aluminum (AMDA) construction. Models SMX / AMX Matching the styling of the SMD / AMD line of diffusers, these are designed for high induction and rapid mixing with the addition of internally mounted discharge vanes. Model SMDP The SMDP design is intended to blend harmoniously with most ceiling systems while the louvered slots supply large volumes of air at relatively low sound levels and pressure drops. Models AMDSR / CSRD These combination supply / return directional diffusers are available in louvered face extruded aluminum construction (AMDSR) as well as aluminum egg crate core (CSRD) return air sections. Models SMCD / AMCD / AMCDP Designed for air pattern adjustment through field modification of louvered modular pattern controllers, PRICE modular core directional diffusers are available in steel (SMCD) and aluminum (AMCD) construction, as well as with a perforated face panel version (AMCDP) for smooth integration with the ceiling. Model CVD / SCVD / ACVD Individually adjustable curved vanes direct supply air precisely to suit the desired application in PRICE model CVD/SCVD/ACVD directional diffusers. A clean, functional appearance with excellent performance characteristics, the CVD/ SCVD/ACVD provides a wide range of application versatility. Types Louvered Face Directional Fixed Pattern Adjustable Pattern Combination Supply / Return, Egg Crate Core High Induction Fixed Pattern Steel Frame Plaque Face Directional Fixed Pattern Modular Core Steel Construction, Perforated Face Screen Curved Vane Extruded formed Steel Construction Formed SMD AMD SMDA AMDA AMDSR CSRD SMX AMX SMDP SMCD AMCD AMCDP CVD SCVD ACVD CEILING DIFFUSERS Copyright E.H. Price Limited All Metric dimensions ( ) are soft conversion. C-85

2 Square and Rectangular Directional Diffusers Types SMD / AMD SMX / AMX SMCD / AMCD / AMCDP CVD / SCVD / ACVD SMDA / AMDA High Induction Modular Core Curved Vane AMDSR / CSRD fixed Pattern Louvered Face Directional Pages C88 - C110 Pages C111 - C118 Pages C119 - C128 Pages C129 - C135 SMDP Plaque Face Directional Pages C106 Quick Selection Guide Diffuser Type Ceiling Type Recommended Border / Panel Louvered Face Lay-In (All diffuser types) SMD / AMD Inverted Tee 1"(25) 3 3P Modular Core Narrow Tee Bar 9/16" (14) 17 17P SMCD / AMCD Concealed Spline 4 4P Curved Vane surface Mount CVD / SCVD / ACVD flush Frame 1 C-86

3 Louvered Face Directional Diffusers CSRD Series Combination Supply / Return Product Information PRICE CSRD Series combination supply / return directional diffusers are available with extruded aluminum louvered blades for supply air and an egg crate core for return air. Extruded aluminum construction matches in detail and styling the Series AMD. The performance characteristics are excellent; the diffuser handles a large amount of air for a given set of outside dimensions with low pressure drop and noise levels. The CSRD is sized to match rooftop air conditioners in the most popular capacities. Features Extruded aluminum construction. Return air core is aluminum egg crate, minimizing see through and maximizing free area Surface mounting flange is applicable to most ceiling types. Finish White Powder Coat B12 For optional and special finishes see color matrix. CEILING DIFFUSERS Product Selection Checklist 1] Select Supply Inlet size L x W based on desired performance characteristics. 2] Select Outlet type by model number. 3] Select Finish. Example: 12" x 12" / CSRD 30 / B12 Product Information Index Performance Data... C110 Suggested Specification...C184 CSRD Selection Criteria Imperial (inches) / Metric (mm) D R Supply Return CSRD / Core Duct Size Duct Opening Ceiling Opening 20 Removable 21 x 21 (533 x 533) 12 x 12 (305 x 305) 24 1 /2 x 24 1 /2 (622 x 622) 30 Removable 24 x 24 (610 x 610) 15 x 15 (381 x 381) 27 1 /2 x 27 1 /2 (698 x 698) 40 Removable 28 1 /2 x 28 1 /2 (724 x 724) 16 1 /2 x 16 1 /2 (419 x 419) 32 x 32 (813 x 813) 50 Removable 33 x 33 (838 x 838) 18 x 18 (457 x 457) 36 1 /2 x 36 1 /2 (927 x 927) 75 Removable 36 x 36 (914 x 914) 21 x 21 (533 x 533) 39 1 /2 x 39 1 /2 (1003 x 1003) 100 Removable 48 x 48 (1219 x 1219) 27 x 27 (686 x 686) 51 1 /2 x 51 1 /2 (1308 x 1308) 150 Fixed 57 x 57 (1448 x 1448) 33 x 33 (838 x 838) 60 1 /2 x 60 1 /2 (1537 x 1537) 200 Fixed 66 x 66 (1676 x 1676) 39 x 39 (991 x 991) 69 1 /2 x 69 1 /2 (1765 x 1765) Copyright E.H. Price Limited All Metric dimensions ( ) are soft conversion. C-109

4 Louvered Face Directional Diffusers CSRD Series Performance Data cfm / ton cfm CSRD 20 Throw, ft T.P. Supply TONS (-S.P.) Return NC cfm CSRD 30 Throw, ft T.P. Supply TONS (-S.P.) Return NC cfm CSRD 40 Throw, ft T.P. Supply TONS (-S.P.) Return NC cfm CSRD 50 Throw, ft T.P. Supply TONS (-S.P.) Return NC cfm CSRD 75 Throw, ft T.P. Supply TONS (-S.P.) Return NC cfm CSRD 100 Throw, ft T.P. Supply TONS (-S.P.) Return NC cfm CSRD 150 Throw, ft T.P. Supply TONS (-S.P.) Return NC cfm CSRD 200 Throw, ft T.P. Supply TONS (-S.P.) Return NC Performance Notes: 1. Tested in accordance with ASHRAE Standard Method of Testing for Rating the Performance of Air Outlets and Inlets. 1. Pressure: All pressures are in inches of water. TP = Total Pressure (-SP) = Negative Static Pressure 2. Throw: Maximum throws are to a terminal velocity of 50 fpm, middle to 100 fpm, and minimum to 150 fpm. 3. Throw data is based on supply air and room air being at isothermal conditions. 4. Sound: The NC values are based on a room absorption of 8 db, re watts and one diffuser. 5. Blanks ( ) indicate an NC level below 15. C-110

5 Suggested Specification Square / Rectangular Directional SMDA-FR AMDSR SMX Supply - Louvered Face, Adjustable Air Pattern, Fire Rated Furnish and install PRICE model SMDA-FR directional louvered face diffusers of the sizes and mounting types shown on the plans and air distribution schedule. Diffusers shall be Fire Rated Assemblies listed in the UL, Underwriters Laboratories Fire Resistance Directory and in the ULC, Underwriters Laboratories of Canada Equipment and Materials Directory. Diffusers shall meet UL time vs. temperature test criteria and NFPA 90A requirements. This design is intended for use in an exposed grid suspended ceiling (T-Bar lay-in) with up to a three-hour rating and must be installed in accordance with installation instructions. assembly which facilitates mounting in the application shown. A collar that allows connection to the square (or rectangular) duct size indicated shall be an integral part of the assembly. An inner core assembly consisting of fixed louvers capable of producing the airflow discharge pattern indicated on the plans shall be fully removable from the installed diffuser frame for access to any dampers or other ductwork components located in or near the diffuser neck. The inner core assemblies shall be identically constructed so that directional core assemblies providing different airflow discharge patterns may be interchanged between frames, provided the frame duct connections are of the same size. A set of adjustment vanes shall be provided on each side of the diffuser which allows field adjustment from horizontal to vertical airflow discharge. Diffuser shall incorporate a nonadjustable butterfly-type ceiling radiation damper, a 165 F (74 C) fusible link, and a non-asbestos thermal blanket. Finish shall be B12 White Powder Coat. Return Furnish and install PRICE model AMDSR (extruded aluminum) square or rectangular neck directional supply and return air combination diffusers of sizes and capacities as shown on the drawings (on the diffuser schedule). Diffuser shall supply air to the space with horizontal air flow pattern through outer slots. Diffuser inner (central) slots shall provide for return air outlet. sub-assembly and removable inner core sub-assembly. Inner core sub-assembly shall be easily and quickly removable to allow access to inside of supply and return air ducts. CSRD Furnish and install PRICE model CSRD square or rectangular neck directional supply and return air combination diffusers of sizes and capacities as shown on the drawings (or the diffuser schedule). Diffuser shall supply air to the space with horizontal air flow pattern through outer slots and return air through a center mounted core of 1 /2" x 1 /2" x 1 /2" aluminum egg crate. Supply section of diffuser shall provide ceiling blanketing air pattern and shall adapt to variable volume roof top units. (flanged) sub-assembly for surface mounting, and removable* inner core along with center egg crate (*on most sizes). Steel Construction Furnish and install Price model SMX louvered rapid mixing diffusers of the sizes and frame types shown on the plans and schedules. Diffusers shall consist of a formed steel outer frame (except frames 6 and 33 which shall have an extruded aluminum frame) assembly which facilitates mounting in the application shown. A collar that allows connection to the square (or rectangular) duct size indicated shall be an integral part of the frame assembly. This collar fits inside the duct. Optional Provide a connecting collar, sized to fit outside the supply duct for a low leakage joint. The formed steel collar shall be welded or clinch locked to the diffuser frame. The inner core assembly shall consist of formed steel fixed louvers capable of producing the airflow discharge pattern indicated on the plans. Steel mixing vanes shall be fastened to the back of the fixed louvers. Vanes shall be designed to produce high induction and rapid mixing of the primary and room air. Inner core assemblies shall be easily removable from the installed diffuser frame for access to any dampers or other ductwork components located in or near the diffuser neck. Options Opposed blade damper shall be of steel construction painted black. Corners of core shall be rounded to facilitate cleaning. Square to round adaptor shall be of coated steel construction. Options volume adjustment for balancing 212 F (100 C) fusible link optional finishes available optional T-Bar Lay-in Panel C-184

Price Egg Crate Grille

Price Egg Crate Grille Price Egg Crate Grille Division 23 Heating, Ventilating, and Air Conditioning Section 23 37 13 Diffusers, Registers, and Grilles The following specification is for a defined application. Price would be

More information

Price Perforated Supply Diffuser

Price Perforated Supply Diffuser Price Perforated Supply Diffuser Division 23 Heating, Ventilating, and Air Conditioning Section 23 37 13 Diffusers, Registers, and Grilles The following specification is for a defined application. Price

More information

Steel Louvered Supply/Return Grille

Steel Louvered Supply/Return Grille 500 Steel Louvered Supply/Return Grille Typical Applications Most commonly used in sidewall applications, 500 Series grilles are available with both supply and return constructions options. With a variety

More information

University of Houston Master Construction Specifications Insert Project Name SECTION AIR DISTRIBUTION DEVICES PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION AIR DISTRIBUTION DEVICES PART 1 - GENERAL SECTION 23 37 13 - AIR DISTRIBUTION DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 01

More information

A. This Section includes ceiling- and wall-mounted diffusers, registers, grilles and louvers.

A. This Section includes ceiling- and wall-mounted diffusers, registers, grilles and louvers. SECTION 23 37 13 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

YORK BULKHEAD MOUNTED CHILLED BEAMS ENGINEERING GUIDE

YORK BULKHEAD MOUNTED CHILLED BEAMS ENGINEERING GUIDE YORK BULKHEAD MOUNTED CHILLED BEAMS ENGINEERING GUIDE Contents YORK Bulkhead Active Chilled Beams 3 CB-ABB-YK / CB-ABC-YK Performance Data 5 CB-ABB-YK Dimensions 10 CB-ABC-YK Dimensions 11 Specifications

More information

10200/ARR Buyline 4822 ARROW LOUVERS. The Preferred Line PUBLICATION

10200/ARR Buyline 4822 ARROW LOUVERS. The Preferred Line PUBLICATION 10200/ARR ARROW LOUVERS The Preferred Line PUBLICATION 697 03 ARROW LOUVERS Arrow Louvers are custom-built, quality assemblies manufactured to meet your design specifications. Our louvers are constructed

More information

PRODUCT BROCHURE. Fixed Helical Swirl Diffuser HSC-FD HSC-FD : smartemp.com

PRODUCT BROCHURE. Fixed Helical Swirl Diffuser HSC-FD HSC-FD : smartemp.com PRODUCT BROCHURE Fixed Helical Swirl Diffuser HSC-FD HSC-FD : 07 smartemp.com DESCRIPTION The SMARTEMP Fixed Helical Swirl Diffuser, type HSC-FD, produces highly inductive swirl discharge, diffusing the

More information

SP Standard Profile. Flanged to Duct Install Type THERMAL BREAKS OPPOSED ACTION PARALLEL ACTION. T.A. Morrison & Co. Inc.

SP Standard Profile. Flanged to Duct Install Type THERMAL BREAKS OPPOSED ACTION PARALLEL ACTION.  T.A. Morrison & Co. Inc. 1 SUBMITTAL DATA Series 9000 BF Thermally Insulated Damper with Thermally Broken Frames & Blades SP Standard Profile Flanged to Duct Install Type THERMAL BREAKS OPPOSED frame is 4 (101.6 mm) deep x 1 (25.4

More information

1.02 Related Sections A. Section Heating, Ventilation and Air Conditioning (HVAC). C. Section Pneumatic and Electric Control HVAC.

1.02 Related Sections A. Section Heating, Ventilation and Air Conditioning (HVAC). C. Section Pneumatic and Electric Control HVAC. PART 1: GENERAL 1.01 Section Includes A. Dual duct terminal units. B. Variable volume regulators. C. Integral damper motor operators. D. Integral controls. 1.02 Related Sections A. Section 23 00 00 Heating,

More information

A. Air diffusers, grilles, and registers: Ratings certified by Air Diffusion Council.

A. Air diffusers, grilles, and registers: Ratings certified by Air Diffusion Council. SECTION 23 33 00 PART 1 - GENERAL 1.01 WORK INCLUDED A. Air distribution registers, grilles, and diffusers B. Fire dampers C. Smoke dampers D. Combination fire and smoke dampers E. Access doors F. Outside

More information

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

AFJ-601. Acoustical Louver J Blade. Application and Design. Standard Construction. Options (at additional cost)

AFJ-601. Acoustical Louver J Blade. Application and Design. Standard Construction. Options (at additional cost) Application and Design Acoustical Louver J Blade is an acoustical weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates J style insulated acoustical

More information

6 Drainable Louver. Update to Louvers Catalog C-1.0. Catalogue Page 2 Page 7. Page LP-13. Submittals Drawing

6 Drainable Louver. Update to Louvers Catalog C-1.0. Catalogue Page 2 Page 7. Page LP-13. Submittals Drawing 6 Drainable Louver Section Page Number Catalogue Page 2 Page 7 Performance Data Page LP-12 Page LP-13 Submittals Drawing 237947 Update to Louvers Catalog C-1.0 April 2010 Louvers General Product Overview

More information

ESD-635. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

ESD-635. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost) Application and Design Stationary Louver Drainable Blade is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates drain gutters in the head

More information

ACBC Floor Mounted Active Beam

ACBC Floor Mounted Active Beam Floor Mounted Active Beam The Price Floor Mounted Active Beam,, is designed for occupant comfort. It provides high cooling and heating capacities while simultaneously supplying ventilation air from a DOAS

More information

ESD-403. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

ESD-403. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost) Application and Design Stationary Louver Drainable Blade is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member

More information

EDD-601. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

EDD-601. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member and stationary horizontal blades to

More information

where high efficiency is the standard

where high efficiency is the standard Access Doors 2016 where high efficiency is the standard Experience Milcor offers years of experience in the manufacture of a broad range of products and services for residential, commercial, institutional

More information

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

A. This Section includes acoustical panel ceilings installed with exposed suspension systems. SECTION 09511 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Fire Dampers. Required information:

Fire Dampers. Required information: Fire Dampers Description: Fire dampers are designed to restrict the spread of fire through ventilation systems by snapping shut when the fusible link melts. 1. What are the dimensions of the damper? Width

More information

EDK-402. Stationary Louver K Blade. Application and Design. Standard Construction. Options (at additional cost)

EDK-402. Stationary Louver K Blade. Application and Design. Standard Construction. Options (at additional cost) Application and Design Stationary Louver K Blade is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates drainable head, K style blades,

More information

EHH-201. Wind-Driven Rain Louver Horizontal Blade. Application and Design. Standard Construction. Options (at additional cost)

EHH-201. Wind-Driven Rain Louver Horizontal Blade. Application and Design. Standard Construction. Options (at additional cost) Application and Design is a Wind-Driven Rain louver designed to protect air intake and exhaust openings in building exterior walls that are sensitive to direct water penetration. Design incorporates a

More information

UNDERFLOOR DISTRIBUTION PRODUCTS UFAD

UNDERFLOOR DISTRIBUTION PRODUCTS UFAD PRODUCTS Round Diffusers Rectangular Diffusers Segmented Linear Diffuser Continuous Linear Plenum Power Supply Module Extruded Aluminum Grille Perimeter Heat/Cool Convector System Airflow Panel UNDERFLOOR

More information

SED-501. Sightproof Louver Drainable Blade. Application and Design

SED-501. Sightproof Louver Drainable Blade. Application and Design Application and Design is a sightproof weather louver designed to protect air intake and exhaust openings in building exterior walls when visual see through prevention is needed. Design incorporates a

More information

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19 Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19 Page 1 or 8 APPLICATION This fi re damper is intended to restrict the passage of fl ame. The standard installation requires that the

More information

ELM6375DX DRAINABLE ADJUSTABLE LOUVER EXTRUDED ALUMINUM

ELM6375DX DRAINABLE ADJUSTABLE LOUVER EXTRUDED ALUMINUM RUSKIN 3900 Dr. Greaves Rd. Grandview, MO 64030 (816) 761-7476 FAX (816) 966-1655 ELM6375DX DRAINABLE ADJUSTABLE LOUVER EXTRUDED ALUMINUM STANDARD CONSTRUCTION FRAME 6 (152) deep, 6063T5 extruded aluminum

More information

ESJ-401RM. Stationary Louver J Blade. Application and Design. Standard Construction. Options (at additional cost)

ESJ-401RM. Stationary Louver J Blade. Application and Design. Standard Construction. Options (at additional cost) Stationary Louver J Blade Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates J style blades, sloped sill and

More information

ACBC Floor Mounted Active Beam

ACBC Floor Mounted Active Beam Floor Mounted Active Beam The Price Floor Mounted Active Beam,, is designed for occupant comfort. It provides high cooling and heating capacities while simultaneously supplying ventilation air from a DOAS

More information

OS-ALD ACOUSTIC LOUVERS

OS-ALD ACOUSTIC LOUVERS OPTIMA Acoustic Louvers Overview OPTIMA Acoustic Louvers are designed to provide optimal acoustic performance (noise reduction) with minimal airflow restrictions. OS-ALD acoustic Louvers are typically

More information

EACA-601. Combination Louver/Damper Airfoil Blade. Application and Design. Standard Construction

EACA-601. Combination Louver/Damper Airfoil Blade. Application and Design. Standard Construction Application and Design is a combination louver/damper designed to protect air intake and exhaust openings in building exterior walls that, at times, require tight air shut off. Design incorporates a drainable

More information

DPG. Low velocity terminal for small airflows QUICK FACTS

DPG. Low velocity terminal for small airflows QUICK FACTS Low velocity terminal for small airflows QUICK FACTS Theatre diffuser for mounting in floor Fixed spread pattern Simple installation Requires no maintenance Cleanable Is available as special order in alternative

More information

WHERE HIGH EFFICIENCY IS THE STANDARD

WHERE HIGH EFFICIENCY IS THE STANDARD ACCESS DOORS 2017 WHERE HIGH EFFICIENCY IS THE STANDARD EXPERIENCE Milcor offers years of experience in the manufacture of a broad range of products and services for residential, commercial, institutional

More information

EACC-601. Combination Louver/Damper Concealed Actuator. Application and Design. Standard Construction

EACC-601. Combination Louver/Damper Concealed Actuator. Application and Design. Standard Construction Application and Design Concealed Actuator is a combination louver/damper designed to protect air intake and exhaust openings in building exterior walls that, at times, require tight air shut off. Design

More information

LOUVER PRODUCTS. Architectural Blade Louvers Drainable Blade Louvers Wind-Driven Rain Louvers Sightproof Louvers Acoustical Louvers Thinline Louvers

LOUVER PRODUCTS. Architectural Blade Louvers Drainable Blade Louvers Wind-Driven Rain Louvers Sightproof Louvers Acoustical Louvers Thinline Louvers LOUVER PRODUCTS Archives of Ontario Building, York University, Toronto, Ontario Architectural Blade Louvers Drainable Blade Louvers Wind-Driven Rain Louvers Sightproof Louvers Acoustical Louvers Thinline

More information

Achieving acoustical standards in the classroom Study of HVAC systems and classroom acoustics

Achieving acoustical standards in the classroom Study of HVAC systems and classroom acoustics Achieving acoustical standards in the classroom Study of HVAC systems and classroom acoustics Trane believes the facts and suggestions presented here to be accurate. However, final design and application

More information

ESD-435X. Florida Product Approved Drainable Blade Louver. Application and Design. Standard Construction. Qualified Shapes

ESD-435X. Florida Product Approved Drainable Blade Louver. Application and Design. Standard Construction. Qualified Shapes Application and Design Florida Product Approved Drainable Blade Louver is a Florida Product Approved stationary drainable blade extruded aluminum louver designed to protect air intake and exhaust openings

More information

EAD-635. Adjustable Louver Drainable Blades. Application and Design. Standard Construction. Options (at additional cost)

EAD-635. Adjustable Louver Drainable Blades. Application and Design. Standard Construction. Options (at additional cost) Application and Design Adjustable Louver Drainable Blades is an adjustable louver designed to protect air intake and exhaust openings in building exterior walls that require tight air shut off. Design

More information

B. Provide fire-rated access doors where indicated or scheduled.

B. Provide fire-rated access doors where indicated or scheduled. SECTION 08305 ACCESS DOORS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

INDIA HABITAT CENTRE New Delhi

INDIA HABITAT CENTRE New Delhi INDIA HABITAT CENTRE New Delhi Tender For Renovation of Exhaust Air Ducting Works in Basements Date: January, 2014 Prepared by Sterling India Consulting Engineers New Delhi, India TABLE OF CONTENTS S.No.

More information

SECTION AIR FILTERS

SECTION AIR FILTERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

SPECIFICATIONS SECTION UL LISTED HEAT AND SMOKE VENTS

SPECIFICATIONS SECTION UL LISTED HEAT AND SMOKE VENTS SPECIFICATIONS SECTION 07 72 00 PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Prefabricated UL Listed heat and smoke vents, with Skypro UL 972 Impact resistant Skywave Arc domed lids, curbs, hardware

More information

Price Single Duct Terminal Units

Price Single Duct Terminal Units Price Single Duct Terminal Units Division 23 Heating, Ventilating, and Air Conditioning Section 23 36 00 Air Terminal Units The following specification is for a defined application. Price would be pleased

More information

SECTION HVAC DUCTS AND CASINGS

SECTION HVAC DUCTS AND CASINGS SECTION 23 31 00 HVAC DUCTS AND CASINGS PART 1 -GENERAL 1.1 SUMMARY A. Section includes metal ductwork, nonmetallic ductwork, casing and plenums, buried ductwork, kitchen hood ductwork, duct cleaning.

More information

SECTION ACCORDION FOLDING PARTITIONS

SECTION ACCORDION FOLDING PARTITIONS PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 22 26.13 ACCORDION FOLDING PARTITIONS SPEC WRITER NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

ESF-145. Thin-line Louver Flat Blade. Application and Design. Standard Construction. Options (at additional cost)

ESF-145. Thin-line Louver Flat Blade. Application and Design. Standard Construction. Options (at additional cost) Application and Design Flat Blade is a thin-line stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow depth makes

More information

EME6325D WIND-DRIVEN RAIN RESISTANT STATIONARY LOUVER

EME6325D WIND-DRIVEN RAIN RESISTANT STATIONARY LOUVER 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 EME6325D WIND-DRIVEN RAIN RESISTANT STATIONARY LOUVER MIAMI-DADE APPROVED MIAMI-DADE COUNTY, FLORIDA NOTICE OF ACCEPTANCE NUMBER:

More information

SECTION METAL DUCTS

SECTION METAL DUCTS SECTION 15815 METAL DUCTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Noise Control. Commercial, Industrial, and Environmental Products and Solutions.

Noise Control. Commercial, Industrial, and Environmental Products and Solutions. Noise Control Commercial, Industrial, and Environmental Products and Solutions www.kineticsnoise.com Commercial Duct Silencers Kinetics Noise Control offers the design and engineering assistance to integrate

More information

PLASTIC DIFFUSERS AND GRILLES LINEAR ELITE DIFFUSER

PLASTIC DIFFUSERS AND GRILLES LINEAR ELITE DIFFUSER LINEAR ELITE DIFFUSER Clips supplied separately. Please specify. FEATURES Two 2mm slots provides high flow rates with low noise levels. One piece construction of the diffuser eliminates unsightly joins.

More information

IntelliPak Ton and IntelliPak II Ton Rooftops

IntelliPak Ton and IntelliPak II Ton Rooftops IntelliPak 20-130 Ton and IntelliPak II 90-150 Ton Rooftops Subject: Indoor Sound Issued by: Clarksville Large Commercial Unitary June 2008 RT-PRB022-EN Table of Contents Engineering Bulletin....................................................

More information

EACA-601D. Miami-Dade Qualified Combination Louver

EACA-601D. Miami-Dade Qualified Combination Louver Miami-Dade Qualified Combination Louver Application and Design is a Florida Product Approved and Miami-Dade Qualified combination louver/damper designed to protect air intake and exhaust openings in building

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 095113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 DEFINITIONS A. AC: Articulation

More information

ESU-150. Thin-line Louver Thin-line Blade. Application and Design. Standard Construction. Options (at additional cost)

ESU-150. Thin-line Louver Thin-line Blade. Application and Design. Standard Construction. Options (at additional cost) Application and Design Thin-line Blade is a thin-line stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow depth

More information

ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION

ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION RUSKIN sand trap louvers are specially designed to separated the sand and dust from the air. It is effective and necessary to apply for ventilations and inlet

More information

SECTION (FORMERLY 11610)

SECTION (FORMERLY 11610) PART 1 GENERAL SECTION 11 53 13 (FORMERLY 11610) OBSERVATION2 STYLE GLASS WALLED FUME HOODS Display hidden notes to specifier by using "Tools/Options/View/Hidden Text Summary: This Specification identifies

More information

PRODUCT BROCHURE. Linear Multistream Ceiling Diffuser LMC-AD LMC-AD : smartemp.com

PRODUCT BROCHURE. Linear Multistream Ceiling Diffuser LMC-AD LMC-AD : smartemp.com PRODUCT BROCHURE Linear Multistream Ceiling Diffuser LMC-AD LMC-AD : 07 smartemp.com DESCRIPTION The SMARTEMP Linear Multistream Ceiling Diffuser, type LMC-AD (figure ), is a multi-nozzle linear slot diffuser

More information

ESU-154. Thinline Louver Thinline Blade. Application and Design. Standard Construction. Options (at additional cost)

ESU-154. Thinline Louver Thinline Blade. Application and Design. Standard Construction. Options (at additional cost) Application and Design Thinline Blade is a thinline stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow depth makes

More information

A. Access doors and frames are part of an access door and frame allowance.

A. Access doors and frames are part of an access door and frame allowance. SECTION 08 31 13 ACCESS DOORS AND FRAMES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm mm

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm mm DESCRIPTION The Define series by Neo-Ray characterizes the ultimate in minimalist simplicity by providing clean, uniform lines of illumination in virtually any architectural environment. Powered by s most

More information

DIVISION 11 - EQUIPMENT FOOD SERVICE EQUIPMENT LABORATORY FUME HOODS. A. Design Considerations

DIVISION 11 - EQUIPMENT FOOD SERVICE EQUIPMENT LABORATORY FUME HOODS. A. Design Considerations DIVISION 11 - EQUIPMENT 11400 FOOD SERVICE EQUIPMENT A. Design Considerations 1. The A/E shall use the services of a food service equipment specialist in preparation of kitchen areas and other food preparation

More information

ANSI/ASHRAE STANDARD , METHODS OF TESTING CHILLED BEAMS

ANSI/ASHRAE STANDARD , METHODS OF TESTING CHILLED BEAMS ANSI/ASHRAE STANDARD 200-2015, METHODS OF TESTING CHILLED BEAMS NEMIC 2017 Agenda 1. Foreword 2. Purpose & Scope 3. Definitions 4. Instrumentation & Facilities 5. Test Methods 6. Reporting 7. Normative

More information

SECTION AIR DUCT CLEANING

SECTION AIR DUCT CLEANING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

Portable Ventilator Product Catalog

Portable Ventilator Product Catalog Portable Ventilator Product Catalog WELCOME For more than 0 years, COPPUS portable ventilators and cooling products have been recognized as leaders in providing reliable, ventilation to meet the demands

More information

Request for Bids. At The Greenville-Spartanburg International Airport

Request for Bids. At The Greenville-Spartanburg International Airport Request for Bids At The Greenville-Spartanburg International Airport Addendum No. 2 June 27, 2011 All Bidders shall include with their bid submittal a signed statement indicating they have reviewed and

More information

FFU-HE High Efficiency Fan Filter Unit

FFU-HE High Efficiency Fan Filter Unit FFU-HE High Efficiency Fan Filter Unit Price High-Efficiency Fan Filter Units (FFU-HE) are the most energy efficient line of fan filter units (fan filter modules) on the market today. Designed specifically

More information

SECTION Manufactured Metal Casework FLEXIBLE LABORATORY FURNITURE SYSTEM (OPTIMA) USA VERSION

SECTION Manufactured Metal Casework FLEXIBLE LABORATORY FURNITURE SYSTEM (OPTIMA) USA VERSION SECTION 12 31 00.4 Manufactured Metal Casework FLEXIBLE LABORATORY FURNITURE SYSTEM (OPTIMA) USA VERSION PART 1 GENERAL Summary: This Specification identifies the minimum material and construction standards

More information

LARGO. Angle sound attenuator with recessed connection for rectangular ducts QUICK FACTS

LARGO. Angle sound attenuator with recessed connection for rectangular ducts QUICK FACTS Angle sound attenuator with recessed connection for rectangular ducts QUICK FACTS Remarkably space-saving rectangular sound attenuator Excellent aerodynamic characteristics Very low pressure drop acoustic

More information

Cooling Tower Noise Control

Cooling Tower Noise Control Providence, Rhode Island Acoustical Society of America 5-9 June 2006 Cooling Tower Noise Control Tom Paige, P.Eng. Products Application Engineer Kinetics Noise Control, Inc. Vibron Products Group Mississauga,

More information

GUIDE SPECIFICATION: DUCT LINER

GUIDE SPECIFICATION: DUCT LINER GUIDE SPECIFICATION: DUCT LINER This specification guide includes thermal & acoustical insulation for ductwork and air handling systems. This section is based on the format recommended by MICA (Midwest

More information

SECTION HVAC GRAVITY VENTILATORS

SECTION HVAC GRAVITY VENTILATORS SECTION 23 37 23 HVAC GRAVITY VENTILATORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

B. Qualification Data: For installers specified in Quality Assurance article.

B. Qualification Data: For installers specified in Quality Assurance article. SECTION 233113 METAL DUCTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS. References are in agreement with UMRL dated 9 October 2006

UNIFIED FACILITIES GUIDE SPECIFICATIONS. References are in agreement with UMRL dated 9 October 2006 USACE / NAVFAC / AFCESA / NASA UFGS-23 30 13.00 20 (July 2006) ------------------------------ Preparing Activity: NAVFAC Superseding UFGS-23 30 13.00 20 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

STACK AND BREECHING GUIDELINE

STACK AND BREECHING GUIDELINE TECHNICAL BULLETIN 1004 DECEMBER 1, 2007 STACK AND BREECHING GUIDELINE Common stacks and breechings can be designed as follows: 1. Determine volume of flue gases from Chart 1. Chart shows flue gas CFM

More information

Noise-Foil Acoustic Metal Panels Sound Absorption Systems for Industry & Commerce

Noise-Foil Acoustic Metal Panels Sound Absorption Systems for Industry & Commerce Noise-Foil Acoustic Metal Panels Sound Absorption Systems for Industry & Commerce Abuse resistant metal jacketed constructions Lab certified acoustic performances Suitable for interior and exterior installations

More information

Manufacturers of Custom Acoustical Ceiling and Wall Products

Manufacturers of Custom Acoustical Ceiling and Wall Products Manufacturers of Custom Acoustical Ceiling and Wall Products I N N O V A T I O N D E S I G N S E R V I C E Q U A L I T Y For over 30 years, Decoustics has been the international leader in design, engineering

More information

SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS

SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS PART 1 GENERAL 1.01 SUMMARY Specifier Note: Revise paragraphs below to suit project requirements. A. Section Includes: Custom fabricated acoustical

More information

Brise Soleil Fixed Sunshades

Brise Soleil Fixed Sunshades Brise Soleil Fixed Sunshades Introduction Linel is headquartered in Mooresville, Indiana and is part of the Mestek Architectural Group. In addition to Linel, Mestek s architectural activities include American

More information

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700 SECTION 09 5113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION SECTION 230713 DUCT INSULATION PART 1 GENERAL 1.1 SUMMARY A. Related Sections: 1. 233113 Ductwork and Accessories 1.2 REFERENCES A. American Society for Testing and Materials (ASTM): 1. E84-96a Test Method

More information

SECTION ORNAMENTAL ALUMINUM FENCING

SECTION ORNAMENTAL ALUMINUM FENCING SECTION 032300 ORNAMENTAL ALUMINUM FENCING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION (FORMERLY 11610)

SECTION (FORMERLY 11610) SECTION 11 53 13 (FORMERLY 11610) LABORATORY FUME HOODS PART 1 GENERAL Summary: This Specification identifies the minimum material and construction standards that are required to deliver a quality installation

More information

SECTION AIR DUCT ACCESSORIES

SECTION AIR DUCT ACCESSORIES SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Patent No. 9,045,900 Technical Glass Products Architectural Specification Manual

Patent No. 9,045,900 Technical Glass Products Architectural Specification Manual Technical Glass Products Architectural Specification Manual 800.426.0279 fireglass.com FIREFRAMES ALUMINUM SERIES INTERIOR APPLICATION ONLY Fireframes Aluminum Series combined with Pilkington Pyrostop

More information

BORTOLOTTO ADDENDUM #2

BORTOLOTTO ADDENDUM #2 BORTOLOTTO ADDENDUM #2 Project LI15-028 English Language Program Lakehead University Chancellor Paterson Library Project # el1606 Location 955 Oliver Road Thunder Bay, Ontario Date June 9, 2016 Pages 1

More information

Wall Louvers (10200)

Wall Louvers (10200) Wall Louvers 08 90 00 (10200) PART 1 GENERAL SECTION INCLUDES A. Fixed, extruded-aluminum horizontal storm resistant louver RELATED SECTIONS A. Section 05120 - Structural Steel: Supports for penthouses.

More information

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466 BUSWAY LOW VOLTAGE (POW-R-WAY III) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein

More information

SECTION (FORMERLY 11610)

SECTION (FORMERLY 11610) SECTION 11 53 13 (FORMERLY 11610) LABORATORY FUME HOODS PART 1 GENERAL Summary: This Specification identifies the minimum material and construction standards that are required to deliver a quality installation

More information

STANDARD PRODUCTS - CUSTOM LOOK

STANDARD PRODUCTS - CUSTOM LOOK AXIOM ClOUDS STANDARD PRODUCTS - CUSTOM LOOK AXIOM AXIOM can give your next space a unique and crisp feel. The AXIOM family offers dramatic visuals with a variety of flat vertical trims and design profiles.

More information

Optimizing Ceiling Systems and Lightweight Plenum Barriers

Optimizing Ceiling Systems and Lightweight Plenum Barriers Optimizing Ceiling Systems and Lightweight Plenum Barriers Gary S. Madaras, ROCKFON, Chicago, Illinois Andrew E. Heuer, NGC Testing Services, Buffalo, New York Acoustics is one of the lowest scoring indoor

More information

Acoustic Louvres. Product and Technical Data

Acoustic Louvres. Product and Technical Data Acoustic Louvres Product and Technical Data INDUSTRIAL & ENVIRONMENTAL NOISE CONTROL SOLUTIONS WORLDWIDE PRODUCT DESCRIPTION Wakefield Acoustics specialises in the design and fabrication of a wide range

More information

ASHRAE Chapter Meeting HVAC Noise & Vibration Control Specifications & Best Practices

ASHRAE Chapter Meeting HVAC Noise & Vibration Control Specifications & Best Practices ASHRAE Chapter Meeting HVAC Noise & Vibration Control Specifications & Best Practices Industrial Presented By OEM Architectural Noise & Vibration Control, Inc. 610-863-6300 www.brd-nonoise.com HVAC Marine

More information

LINEAR METAL CEILINGS Section

LINEAR METAL CEILINGS Section PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information

BGR-SA Series. features: 19 gangable enclosures. what great systems are built on.

BGR-SA Series. features: 19 gangable enclosures. what great systems are built on. GR-S Series 19 gangable enclosures next generation rack, designed with significant installation and performance benefits features: Provides more rackspace in a smaller overall height than similar racks

More information

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 Part 1 General 1.01 Work Included A. The work under this section shall include the furnishing of all items shown on the drawings and as specified,

More information

Architectural Specification Manual

Architectural Specification Manual Architectural Specification Manual SteelBuilt Curtainwall INFINITY System The SteelBuilt Curtainwall Infinity System can use as a back mullion almost any type of custom steel member, such as stainless

More information

SECTION TURBINE VENTILATORS

SECTION TURBINE VENTILATORS SECTION 07 72 00 TURBINE VENTILATORS **This is a CSI Three-Part Specification using CSI MasterFormat 2004-2010 Section Numbers and Titles. This specification must be edited to suit your particular project.

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 095133 - ACOUSTICAL METAL PAN CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

The System Slotted Deflection Track (pat# 5,913,788)

The System Slotted Deflection Track (pat# 5,913,788) The System Slotted Deflection Track (pat# 5,913,788) UBC 1997/CBC 1997 Section 702. Definitions A FIRE-RESISTIVE JOINT SYSTEM is an assemblage of specific materials or products that are designed, tested,

More information

Discussion of the Use of Transfer Grilles to Facilitate Return Air Flow in Central Return Systems

Discussion of the Use of Transfer Grilles to Facilitate Return Air Flow in Central Return Systems building science.com 2008 Building Science Press All rights of reproduction in any form reserved. Discussion of the Use of Transfer Grilles to Facilitate Return Air Flow in Central Return Systems Building

More information