Profile metalice pentru sisteme gips-carton Metallic profiles for gypsum boards

Size: px
Start display at page:

Download "Profile metalice pentru sisteme gips-carton Metallic profiles for gypsum boards"

Transcription

1 METAL WORK INDUSTRY Popeºti Leordeni, ªos. de Centurã a Municipiului Bucureºti, Nr. 103, Judeþul Ilfov, Cod Poºtal Tel.: (004) ; (004) ; (004) ; (004) ; Fax: (004) office@metalwork.ro Web-site:

2 pentru plafoane gips-carton Metallic profiles for gypsum board ceilings 21 PROFILE PERIMETRALE PERIMETER PROFILES Profilele perimetrale în formã de U, destinate plafoanelor false ºi pereþilor din gips-carton, sunt elemente metalice realizate din tablã zincatã, prin laminare la rece, cu grosimea de mm sau mm. Utilizãri: realizarea plafoanelor cu schelet de susþinere metalic; placarea pereþilor; montarea bordurilor de margine pentru a prelua inegalitãþile peretelui; înglobarea ºi fixarea de pereþi a profilelor de susþinere la tavanele din gips-carton; realizarea racorduri la tavan; confecþionarea mãºtilor ºi a pereþilor pentru instalaþii; mascarea rosturilor de dilataþie. UD21/05 UD21/06 UD28/05 UD28/ x190x220 x190x220 x190x300 x190x300 Lungimile standard ale profilelor sunt de mm ºi 4000 mm. La cererea clienþilor, aceste produse se pot U-shaped perimeter profiles for fake ceilings and gypsum-board walls, are metallic elements made of zinced metal sheets, cold laminated, 0.5 or 0.6 mm thick. Uses: metallic support structure ceilings; wall plating; mounting side rims for taking over the irregularities of the wall; incorporating and fastening support profiles for gypsum-board ceilings; ceiling connections; making shields and walls for installations; masking dilatation joints. The standard lengths of the profiles are mm and 4000 mm. Upon clients' request, these products may be manufactured also in other sizes. Delivered in packages. 21/

3 pentru plafoane gips-carton Metallic profiles for gypsum board ceilings 22 PROFILE PORTANTE BEARING PROFILES Profilele portante tip CD, realizate din tablã zincatã, prin laminare la rece, cu grosimea de mm sau mm, sunt profilele de susþinere ale plafoanelor false, de ele fiind fixate plãcile din gips-carton. În funcþie de procedeul de suspendare ºi încãrcare, existã diverse soluþii. Dimensiunile acestora se potrivesc cu dimensiunile profilelor perimetrale în formã de U cu care se îmbinã. Utilizãri: realizarea plafoanelor false; mascara rosturilor de dilataþie; realizarea racordurilor la tavan; mascãri din gips-carton. CD 50/ / 15 CD50//15 CD50//27 CD50//27 CD60//15 CD60//15 CD60//27 CD60// x250x400 x250x400 x450x400 x450x400 x250x530 x250x530 x450x530 x450x530 Avantaje: uºor de montat (datoritã sistemului de noduri flexibil, modular); economic (chiar ºi pentru structuri portante cu geometrii complicate); sigur ( datoritã proiectãrii tehnice îmbunatãþite a sistemului). Lungimile standard ale profilelor sunt de mm ºi 4000 mm. La cererea clienþilor, aceste produse se pot 15/27 CD carrying profiles, made of zinced metal sheets, by cold lamination, 0.5 or 0.6 mm thick, are profiles used to support fake ceilings, fastened to gypsum-board plates. Depending on the suspension and loading procedure, there are various solutions. Their sizes match the sizes of the U-shaped perimeter profiles with which they connect. 15/27 50/60 Uses: fake ceilings; masking dilatation joints; ceiling connections; gypsum-board shields. Advantages: easy to mount (due to the flexible and modular node system); economical (even for carrying structures with complicated geometries); safe (due to the enhanced technical design of the system). The standard lengths of the profiles are mm and 4000 mm. Upon clients' request, these products may be manufactured also in other sizes. Delivered in packages. 24 5

4 pentru plafoane gips-carton Metallic profiles for gypsum board ceilings 23 TRAVERSA CLIP 24 CROSSING PATCH PROFILE OMEGA OMEGA TYPE PROFILES Traversa CLIP pentru profilele CD este elementul metalic realizat prin laminare la rece din tabla zincata cu grosimea de mm, utilizat pentru fixarea profilelor CD. Se livreaza în pachete. The CLIP cross for the CD profiles is the metallic element achieved through the cold rolling process of the hot deep galvanized steel, thikness 0.60 mm and it is used for the CD profiles cliping. Delivered in packages. TR CLIP x155x710 Profilele Omega, destinate plafoanelor false ºi pereþilor din gips-carton, sunt elemente metalice realizate din tablã de oþel zincatã, prin laminare la rece, cu grosimea de mm sau mm. Se utilizeazã la placarea pereþilor cu panouri din gips-carton pentru a prelua inegalitãþile peretelui. Lungimile standard ale profilelor sunt de mm ºi 4000 mm. La cererea clienþilor, aceste produse se pot Omega profiles, for fake ceilings and gypsum-board walls, are metallic elements made of zinced metal sheet, by cold lamination, 0.5 or 0.6 mm thick. Used in plating walls with gypsum-board panels for taking over the inequalities of the wall. The standard lengths of the profiles are mm and 4000 mm. Upon clients' request, these products may be manufactured also in other sizes. Delivered in packages Omega 20/05 Omega 20/ x170x700 x170x

5 pentru pereþi despãrþitori Metallic profiles for separating walls 25 GHIDAJE "U" "U" TYPE GUIDES Ghidajele în formã U sunt elemente metalice confecþionate din tablã zincatã, prin laminare la rece, cu grosimea de mm sau mm ºi utilizate pentru scheletul pereþilor despãrþitori din gips-carton. Utilizãri: primirea ºi transmiterea încãrcãrilor din scheletul metalic de susþinere al pereþilor de gips-carton, cãtre structura de rezistenþã a clãdirii; realizarea structurilor pentru pereþi de compartimentare, cu fixarea în podea ºi plafon; placarea pereþilor. UW50 UNI/05 UW50 UNI/06 UW75 UNI/05 UW75 UNI/06 UW100 UNI/05 UW100 UNI/ x360x330 x360x330 x360x450 x360x450 x360x610 x360x610 Lungimile standard ale profilelor sunt de mm ºi 4000 mm. La cererea clienþilor, aceste produse se pot U guides are metallic elements made of zinced metal sheet, by cold lamination, 0.5 or 0.6 mm thick, used for the structure of gypsum-board partitioning walls. Uses: receiving and transmitting loads from the metallic structure for supporting gypsum-board walls, to the resistance structure of the building; making structures for partitioning walls, by fastening to the floor and ceiling; wall plating. 35 The standard lengths of the profiles are mm and 4000 mm. Upon clients' request, these products may be manufactured also in other sizes. Delivered in packages. 50/75/

6 pentru pereþi despãrþitori Metallic profiles for separating walls 26 GHIDAJE "U" NORMA DIN "U" TYPE GUIDES ACCORDING TO DIN Ghidajele în formã U norma DIN sunt elemente metalice cu alte dimensini ale laturilor exterioare, confecþionate din tablã zincatã, prin laminare la rece, cu grosimea de mm sau mm ºi realizate pentru scheletul pereþilor despãrþitori din gips-carton. Utilizãri: primirea ºi transmiterea încãrcãrilor din scheletul metalic de susþinere al pereþilor de gips-carton, cãtre structura de rezistenþã a clãdirii; realizarea structurilor pentru pereþi de compartimentare, cu fixarea în podea ºi plafon; placarea pereþilor. UW50 DIN/05 UW50 DIN/06 UW75 DIN/05 UW75 DIN/06 UW100 DIN/05 UW100 DIN/ x470x330 x470x330 x470x450 x470x450 x470x610 x470x610 Lungimile standard ale profilelor sunt de mm ºi 4000 mm. La cererea clienþilor, aceste produse se pot DIN-norm U guides are metallic elements, with other sizes of the exterior sides, made of zinced metal sheet, by cold lamination, 0.5 or 0.6 mm thick, used for the structure of gypsum-board partitioning walls. Uses: receiving and transmitting loads from the metallic structure for supporting gypsum-board walls, to the resistance structure of the building; making structures for partitioning walls, by fastening to the floor and ceiling; wall plating. The standard lengths of the profiles are mm and 4000 mm. Upon clients' request, these products may be manufactured also in other sizes. Delivered in packages. 50/75/

7 pentru pereþi despãrþitori Metallic profiles for separating walls 27 MONTANÞI "C" "C" TYPE BEAMS Montanþii CW, profile de structurã pentru pereþii despãrþitori din gips-carton, sunt elemente metalice realizate din tablã zincatã, prin laminare la rece, cu grosimea de mm sau mm. Aceºtia se monteazã în ghidajele UW, fiind montaþii verticali ai scheletului pereþilor din gips-carton. Plãcile din gips-carton se fixeazã de montanþii CW a cãror lungime urmãreºte înãlþimile interioare uzuale la clãdiri, astfel, cantitatea pierderilor din tãierea la dimensiune a profilelor sã fie minimã. Pentru o îmbinare perfectã, fãrã elemente speciale, dimensiunile montanþilor CW se potrivesc cu cele ale ghidajelor UW. Montanþii de tip C sunt telescopici (se pot îmbina si prelungi fãrã alte accesorii). Lungimile standard ale profilelor sunt de mm ºi 4000 mm. La cererea clienþilor, aceste produse se pot confecþiona ºi la alte dimensiuni. Se livreazã în pachete. CW50 UNI/05 CW50 UNI/06 CW75 UNI/05 CW75 UNI/06 CW100UNI/05 CW100UNI/ x410x340 x410x340 x410x500 x410x500 x410x645 x410x645 CW stanchions, structural profiles for gypsum-board partitioning walls, are metallic elements made of zinced metal sheet, by cold lamination, 0.5 or 0.6 mm thick. They are mounted in UW guides, being the vertical stanchions of the structure of gypsum-board walls. The gypsum-board plates are fastened to the CW stanchions whose length matches the interior heights used in buildings, thus, the quantity of waste from cutting the profiles to the size is minimum. In order to achieve perfect joining, without special elements, the sizes of the CW stanchions match those of the UW guides. C stanchions are telescopic (they can be joined and extended without other accessories). The standard lengths of the profiles are mm and 4000 mm. Upon clients' request, these products may be manufactured also in other sizes. Delivered in packages /75/

8 pentru pereþi despãrþitori Metallic profiles for separating walls 28 MONTANÞI "C" NORMA DIN "C" TYPE BEAMS ACCORDING TO DIN Montanþii CW norma DIN, profile de structurã a pereþilor despãrþitori din gips-carton, sunt elemente metalice realizate din tablã zincatã, prin laminare la rece, cu grosimea de mm sau mm. Aceºtia se monteazã în ghidajele UW norma DIN, fiind montaþii verticali ai scheletului pereþilor din gips-carton. Plãcile din gips-carton se fixeazã de montanþii CW norma DIN a cãror lungime urmãreºte înãlþimile interioare uzuale la clãdiri, astfel, cantitatea pierderilor din tãierea la dimensiune a profilelor sã fie minimã. Pentru o îmbinare perfectã, fãrã elemente speciale, dimensiunile montanþilor CW norma DIN se potrivesc cu cele ale ghidajelor UW norma DIN. Montanþii de tip C norma DIN sunt telescopici (se pot îmbina si prelungi fãrã alte accesorii). Lungimile standard ale profilelor sunt de mm ºi 4000 mm. La cererea clienþilor, aceste produse se pot CW50 DIN/05 CW50 DIN/06 CW75 DIN/05 CW75 DIN/06 CW100 DIN/05 CW100 DIN/ x475x340 x475x340 x475x500 x475x500 x475x645 x475x645 DIN-norm C stanchions, structural profiles for gypsum-board partitioning walls, are metallic elements made of zinced metal sheet, by cold lamination, 0.5 or 0.6 mm thick. They are mounted in DIN-norm UW guides, being the vertical stanchions of the structure of gypsum-board walls. The gypsum-board plates are fastened to the DIN-norm CW stanchions, whose length matches the interior heights used in buildings, thus, the quantity of waste from cutting the profiles to the size is minimum. In order to achieve perfect joining, without special elements, the sizes of the DIN-norm CW stanchions match those of the DIN-norm UW guides. DIN-norm C stanchions are telescopic (they can be joined and extended without other accessories). The standard lengths of the profiles are mm and 4000 mm. Upon clients' request, these products may be manufactured also in other sizes. Delivered in packages /75/

SECTION NON-STRUCTURAL METAL FRAMING

SECTION NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 22 16 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

TYPICAL BEARING WALL FRAMING

TYPICAL BEARING WALL FRAMING BASIC WOOD FRAMING City of Grand Rapids Building Safety Division 218-326-7601 www.grandrapidsmn.org This handout is intended only as a guide and is based in part on the 2007 Minnesota State Building Code,

More information

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER: 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-3336 Reissued 01/2015 This report is subject to renewal 01/2017. DIVISION: 09 00 00 FINISHES

More information

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN STEEL STUD AND TRACK FOR DRYWALL PARTITIONS TAKE ADVANTAGE OF THE SAVINGS IN TIME

More information

DICTATOR Lift Shaft System

DICTATOR Lift Shaft System DICTATOR Lift Shaft System The Modular Lift Shaft System, also for Retrofitting Certified According to EN 1090 A lift is becoming more and more important for daily life, not only in newly constructed buildings

More information

EDGEWATER, FLORIDA JUNE 14, 2010

EDGEWATER, FLORIDA JUNE 14, 2010 SECTION 09 2116 - NON-LOAD-BEARING STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1

More information

Trellis System Price List. December 17, 2014 Updated February 25,

Trellis System Price List. December 17, 2014 Updated February 25, Trellis System Price List December 17, 2014 Updated February 25, 2015 800-424-2432 Contents Refer to KI Terms & Conditions document or visit ki.com. 1 Trellis General Information 2 Trellis Power and Data

More information

LISTING INFORMATION OF SIPA - Structural Insulated Panels (SIPs) SPEC ID: Structural Insulated Panel Association (SIPA) P.O.

LISTING INFORMATION OF SIPA - Structural Insulated Panels (SIPs) SPEC ID: Structural Insulated Panel Association (SIPA) P.O. LISTING INFORMATION OF SIPA - Structural Insulated Panels (SIPs) SPEC ID: 32805 Structural Insulated Panel Association (SIPA) P.O. Box 39848 Fort Lauderdale, FL 33339 This report is for the exclusive use

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING

SECTION HANGERS AND SUPPORTS FOR PLUMBING SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 13686.00 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 230529-1 SECTION 230529 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 1.1 SUMMARY A. Section Includes: 1. Metal pipe hangers and supports.

More information

system 150 modular hinge-down clip-in tiles (concealed grid) SAS International +44 (0)

system 150 modular hinge-down clip-in tiles (concealed grid) SAS International +44 (0) metal ceilings system 150 modular hinge-down clip-in tiles (concealed grid) SAS International +44 (0) 118 929 0900 www.sasint.co.uk system 150 information System Description SAS System 150 is a range of

More information

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance Pei Evaluation Service is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Assembly Evaluation Report represents a product that Pei ES has Evaluated. This Assembly Evaluation

More information

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1812 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 09 00

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT SECTION 220529 - HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The General Conditions, Special Conditions and Division 1 through Division 22 as set forth in

More information

Protan Exposed Membrane Roof. Your design - Our solution

Protan Exposed Membrane Roof. Your design - Our solution Protan Exposed Membrane Roof Your design - Our solution Exposed membrane roof The principle function of a roof is to provide durable protection against the external environment to a building. Unprotected

More information

SECTION SOUND ISOLATION

SECTION SOUND ISOLATION SECTION 13085 SOUND ISOLATION PART 1 GENERAL 1.1 SECTION INCLUDES A. Resilient sound isolation clips installed with drywall furring channels for support of gypsum board for noise control (de-coupling)

More information

SECTION HANGERS AND SUPPORTS PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

SECTION HANGERS AND SUPPORTS PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section. 1.01 RELATED DOCUMENTS SECTION 15060 HANGERS AND SUPPORTS PART 1 - GENERAL A. Drawings and Division 1 Specification Sections, apply to this Section. 1.02 SUMMARY A. This Section includes hangers and supports

More information

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

SECTION BASIC ELECTRICAL MATERIALS AND METHODS SECTION 26 05 05 BASIC ELECTRICAL MATERIALS PART 1 - GENERAL 1.1 SUMMARY A. Section includes the limited scope construction materials and methods for application with electrical installations as follows:

More information

ETALLODOMI S.A. Head Office: 12, Kastorias str Athens GREECE. Main Warehouse: 49, Agiou Orous str. GREECE

ETALLODOMI S.A. Head Office: 12, Kastorias str Athens GREECE. Main Warehouse: 49, Agiou Orous str. GREECE About the company... METALLODOMI S.A. was founded in 1995 and since then is experiencing a constant growth. The company operates primarily in steel sheet processing sector and in particular the production

More information

Welding Elements Catalogue

Welding Elements Catalogue Quality meets Innovation Welding Elements Catalogue 2017 - Welding Elements Catalogue Welding Elements Welding Elements Catalogue Issue 06/2017 Transmission and duplication of this document, dissemination

More information

easy formwork system

easy formwork system easy formwork system Ponteggi Edilponte S.p.A. was created in 1963 in a small building in Povegliano Veronese. Thanks to the experience acquired in more than 40 years of activity in the national and international

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT Page 220529-1 SECTION 220529 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT SECTION 220529 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Steel pipe hangers and supports. 2. Metal framing systems. 3. Thermal-hanger shield inserts. 4. Fastener systems.

More information

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD SECTION 09250 GYPSUM BOARD PART 1GENERAL 1.1 SUMMARY A. Related Documents: General and Supplementary Conditions of the Contract, Division 1 - General Requirements, and Drawings are collectively applicable

More information

BORTOLOTTO ADDENDUM #2

BORTOLOTTO ADDENDUM #2 BORTOLOTTO ADDENDUM #2 Project LI15-028 English Language Program Lakehead University Chancellor Paterson Library Project # el1606 Location 955 Oliver Road Thunder Bay, Ontario Date June 9, 2016 Pages 1

More information

Mezzanines. Multiply useful surface area by adding one or more additional floors

Mezzanines. Multiply useful surface area by adding one or more additional floors Mezzanines Multiply useful surface area by adding one or more additional floors An intelligent, economical solution to fully utilise warehouse spaces at heights Mecalux mezzanines are steel structures

More information

Cold Rooms Kide

Cold Rooms Kide COLD ROOMS Cold Rooms 2 Cold under control KIDE it is a business Group manufacturer of cold-rooms, insulation panels, insulated doors, refrigeration units and drying units, offering integral solutions

More information

SECTION ACCORDION FOLDING PARTITIONS

SECTION ACCORDION FOLDING PARTITIONS PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 22 26.13 ACCORDION FOLDING PARTITIONS SPEC WRITER NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,

More information

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following: SECTION 10501 PERSONNEL DUTY LOCKERS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 specifications

More information

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System SECTION 13096 RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13096-1 RF WELDED SYSTEM PART 1 GENERAL 1.1 SECTION

More information

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code LEGACY REPORT Reissued January 1, 2000 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900 Montclair

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT SECTION 220529 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 Part 1 General 1.01 Work Included A. The work under this section shall include the furnishing of all items shown on the drawings and as specified,

More information

Simplos. Multi-Purpose Shelving

Simplos. Multi-Purpose Shelving Simplos Multi-Purpose Shelving Simplos shelving The Simplos system provides the best solution for a broad range of storage applications that conform with manually handled light and medium loads. The main

More information

I-STUD Shaftwall System

I-STUD Shaftwall System I-STUD Shaftwall System Summit Tower I-Stud and CertainTeed Shaftliner TM MILL CERTIFIED Steel-Con 00% GALVANIZED Steel Construction Systems UL Evaluation Report No. ER3660-02 Intertek The I-Stud is approved

More information

Concepts. Products. Service. Partitions Lindner Logic

Concepts. Products. Service. Partitions Lindner Logic Concepts Products Service Partitions Lindner Logic Building new solutions. Lindner undertakes major projects worldwide in all areas of interior fit-out, insulation technology, industrial services and building

More information

Light-Duty Cabinet. The Rousseau Advantages LIGHT-DUTY CABINET. For More Information: CABINET

Light-Duty Cabinet. The Rousseau Advantages LIGHT-DUTY CABINET.  For More Information: CABINET Light-Duty Cabinet For More Information: 866-333-0728 The Rousseau Advantages 100 lb capacity per. 100% access to contents. Variety of accessories available : hanging file bars, plastic bins and dividers.

More information

SHAFTWALL C-H STUD FIRE RATING ENGINEERING CATALOG

SHAFTWALL C-H STUD FIRE RATING ENGINEERING CATALOG SHAFTWALL C-H STUD FIRE RATING ENGINEERING CATALOG 1-800-275-2279 STEELER INC. Shaft Walls C-H Studs & J-Track for Shaft Wall Construction 1-800-275-2279 STEELER C-H Studs can be used in the Shaft Wall

More information

WHAT IS CANTILEVER RACK?

WHAT IS CANTILEVER RACK? PRODUCT INFORMATION WHAT IS CANTILEVER RACK? 2946 Larimer St. Denver, CO 80205 303-295-1100 / 800-373-7693 FAX 303-295-2464 Email info@snyderequipment.com www.snyderequipment.com MODERN EQUIPMENT COMPANY,

More information

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 29 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply

More information

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation.

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation. SECTION B Steel Frame Wall Systems. Contents. SUBJECT Steel Stud Selection Tables Introduction Design Considerations Installation Components PAGE B2 B4 B4 B6 B7 System Specifications Single Stud Staggered

More information

Industrial Doors. Hangar Doors. Sliding Type

Industrial Doors. Hangar Doors. Sliding Type Industrial Doors Hangar Doors Sliding Type Alu Line Aluminium Doors Foldy Folding door, ground supported Folding to one or both sides Motor-operated Deadman control Maximum height 13.60m. Industrial door

More information

SELF-CLIMBING SYSTEMS

SELF-CLIMBING SYSTEMS High efficiency for highrise construction Table of content ATR Self-climbing system RKS Rail climbing system HWS Perimeter safety screen Basic components 8 11 14 ATR Self-Climbing Systems Features Formwork

More information

DEKO PF. Profile Free System Partition

DEKO PF. Profile Free System Partition DEKO PF Profile Free System Partition 2 DEKO PF - The Alternative to Conventional Drywalls Even though glazed partitions have become a constituent part of con temporary fitting out, the demand for system

More information

City of Winnipeg BASES, HANGERS AND SUPPORTS Section NEWPCC - Pump Well Isolation Page 1 of 6 Tender No June 2003

City of Winnipeg BASES, HANGERS AND SUPPORTS Section NEWPCC - Pump Well Isolation Page 1 of 6 Tender No June 2003 NEWPCC - Pump Well Isolation Page 1 of 6 PART 1 General 1.1 RELATED SECTIONS.1 Section 01001 General Requirements..2 Section 03300 - Cast-in-Place Concrete..3 Section 05121 - Structural Steel for Buildings..4

More information

1 Technical University of Cluj-Napoca, Faculty of Architecture and Urbanism, 34-36 Observatorului Str., 400500, Cluj-Napoca, Romania Received 12 May 2011; Accepted 20 August 2011 Structure has a manifold

More information

Dynamic Impact Test of the Railing with Dissipative Elements

Dynamic Impact Test of the Railing with Dissipative Elements ANALELE UNIVERSITĂłII EFTIMIE MURGU REŞIłA ANUL XX, NR. 1, 013, ISSN 1453-7397 Eugen-Marius Afronie, Tiberiu Ștefan Mănescu, Constantin Vasile Bîtea Dynamic Impact Test of the Railing with Dissipative

More information

Product Guide Specification

Product Guide Specification PAC International, Inc. December 2007 Las Vegas, NV 89128 Toll Free (866) RSIC-100 (866) 774-2100 Fax (866) 649-2710 Web Site www.pac-intl.com E-Mail info@pac-intl.com Product Guide Specification Specifier

More information

STUDIU COMPARATIV PRIVIND COSTURILE DE FABRICATIE A UNEI PIESE REPREZENTATIVE

STUDIU COMPARATIV PRIVIND COSTURILE DE FABRICATIE A UNEI PIESE REPREZENTATIVE STUDIU COMPARATIV PRIVIND COSTURILE DE FABRICATIE A UNEI PIESE REPREZENTATIVE Gabriela Georgeta NICHITA Universitatea din Oradea, e-mail: gnichita@uoradea.ro Abstract: By comparative study in this paper,

More information

built build to slabs SLABFORM

built build to slabs SLABFORM uilt build to slabs slabform SLABS Company Projects Products It is a modular system of formworks in aluminium for the execution of monolithic or lightened concrete slabs cast in place. is a fully It

More information

SECTION ACCESS PANELS

SECTION ACCESS PANELS SECTION 08310 ACCESS PANELS PART 1: GENERAL 1.01 RELATED DOCUMENTS Drawings and general provisions of the contract, including supplementary conditions and Division 1 specification sections, apply to this

More information

Concepts. Products. Service. Partition - Lindner Logic 670

Concepts. Products. Service. Partition - Lindner Logic 670 Concepts Products Service Partition - Lindner Logic 670 Building new solutions. Lindner undertakes major worldwide projects in all areas of interior finishes, insulation technology, industrial services

More information

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

AND ACCESSORIES FOR DRYWALL CONSTRUCTION STEEL TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION Quality in your corner. THE STRENGTH WITHIN MONTREAL TORONTO CALGARY EDMONTON VANCOUVER STEEL TRIMS AND ACCESSORIES for Construction BAILEY HAS YOUR

More information

Tel: Fax: T2 Website: Proici Website:

Tel: Fax: T2 Website:  Proici Website: Our Mezznine floors are designed and installed to fully comply with all aspects of the Building Regulations, CDM and Health & Safety requirements. Each floor being individually designed to suit specific

More information

BEARING METAL STUD FRAMING

BEARING METAL STUD FRAMING L-1 Section 05410 Long Form Specification LOAD BEARING METAL STUD FRAMING This section includes axially loaded steel studs, with unique slotted top channels, usually of 0.91, 1.2 and 1.5 mm (16, 18, or

More information

Section GYPSUM DRYWALL

Section GYPSUM DRYWALL Section 09250 GYPSUM DRYWALL 1.00 GENERAL: A. Gypsum Association Specification GA216 and manufacturer's instruction (whichever is more stringent). 2.00 DRYWALL MATERIALS: A. Exposed Gypsum Board: ASTM

More information

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION

More information

built build to FORMWORKS CLIMBING, RETAINING WALLS, SPECIAL

built build to FORMWORKS CLIMBING, RETAINING WALLS, SPECIAL uilt build to FORMWORKS Company Projects Products CLIMBING SYSTEMS Pilosio s CLIMBING SYSTEM with mechanical handling enable vertical construction joints to be created in succession without the aid of

More information

FROM: PROPOSED SUBSTITUTION: Use HILTI X-CW Ceiling Wire for Suspended Ceiling Systems

FROM: PROPOSED SUBSTITUTION: Use HILTI X-CW Ceiling Wire for Suspended Ceiling Systems DATE: PROJECT: TO: FROM: SUBJECT: HILTI X-CW CEILING WIRE FASTENER SUBSTITUTION REQUEST SPECIFICATION TITLE: SECTION: PAGE: ARTICLE/PARAGRAPH: DESCRIPTION: DESIGN DETAIL NO.: PROPOSED SUBSTITUTION: Use

More information

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE ICC EVALUATION SERVICE, INC. Evaluate P Inform P Protect ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) AC191 Approved May 2008 Effective June 1, 2008 Previously approved February 2008, October 2007,

More information

M7 Shelving for picking

M7 Shelving for picking M7 Shelving for picking 2 M7 SHELVING FOR MEDIUM AND LARGE LOADS Storage system for manual picking of products following the man-to-goods principle. Its main benefits are: - Possibility of storing medium

More information

I-STUD Shaftwall System

I-STUD Shaftwall System I-STUD Shaftwall System Summit Tower Spokane, WA I-Stud and CertainTeed Shaftliner MILL CERTIFIED 00% GALVANIZED UL Evaluation Report No. ER3660-02 Intertek SCAFCO I-Stud is approved with the following

More information

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION 230529 - HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of Contract, including General Conditions and other Division 1 Specification Sections,

More information

CEILING & WALL SYSTEMS

CEILING & WALL SYSTEMS CEILING & WALL SYSTEMS Axiom Perimeter Trim Commercial Ceilings and Walls Solutions Guide Axiom Perimeter Trim AXIOM Trim The Axiom family of products provide functional and visual options in ceiling design.

More information

e. Cutouts and Holes for Toilet Accessories: Made to template and edge-reinforced.

e. Cutouts and Holes for Toilet Accessories: Made to template and edge-reinforced. TOILET COMPARTMENTS GENERAL INFORMATION 1.1 Unless otherwise directed by CU Facilities toilet compartments shall be floor-supported, and urinal screens shall be wall hung, with anchoring devices and accessories

More information

An innovative and versatile concept offering countless solutions for all your storage needs from simple single bays to multi-tier installations.

An innovative and versatile concept offering countless solutions for all your storage needs from simple single bays to multi-tier installations. S T E E L S H E E T S H E L V I N G An innovative and versatile concept offering countless solutions for all your storage needs from simple single bays to multi-tier installations. Technical characteristics:

More information

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel

More information

PROTAN EXPOSED ROOF SYSTEMS

PROTAN EXPOSED ROOF SYSTEMS PROTAN EXPOSED ROOF SYSTEMS STANDARD OVERLAP SECRET-FIX PROVAC PRE-FABRICATED SHEETS ADHERED PROTAN SOLUTIONS the forefront of membrane technology. Protan (UK) Ltd offers a range of oldest roofs continue

More information

Originally Issued: 03/08/2013 Revised: 03/14/2017 Valid Through: 03/31/2019

Originally Issued: 03/08/2013 Revised: 03/14/2017 Valid Through: 03/31/2019 EVALUATION SUBJECT: ALUR DIVIDING WALL REPORT HOLDER: Modular Architectural Interiors LLC dba MAI 330 Waterloo Valley Road Mount Olive, NJ 07828 Phone: (973) 446-2300 Fax: (973) 446-2399 www.maispace.com

More information

SECTION MODULAR GALVANIZED RF SHIELDING SYSTEM SPECIFICATIONS

SECTION MODULAR GALVANIZED RF SHIELDING SYSTEM SPECIFICATIONS SECTION 13096 MODULAR GALVANIZED RF SHIELDING SYSTEM SPECIFICATIONS Prepared by: NELCO 125 Chenoweth Lane, Ste. 206 Louisville, KY 40207 (502) 899-3726 13096-1 MODULAR GALVANIZED RF SHIELDING SYSTEM PART

More information

FIGURE R502.2 FLOOR CONSTRUCTION

FIGURE R502.2 FLOOR CONSTRUCTION CHAPTER 5 FLOORS 11 I SECTION R501 GENERAL R501.1 Application. The provisions of this chapter shall control the design and construction of the floors for all buildings including the floors of attic spaces

More information

Why Insulate? - Thermal Control Certified Faced Insulation acts as a barrier to slow down the movement of heat, keeping it inside the building in wint

Why Insulate? - Thermal Control Certified Faced Insulation acts as a barrier to slow down the movement of heat, keeping it inside the building in wint Insulation Why Insulate? - Thermal Control Certified Faced Insulation acts as a barrier to slow down the movement of heat, keeping it inside the building in winter and outside in summer. Why Insulate?

More information

Knauf MF Suspended Ceilings

Knauf MF Suspended Ceilings Suspended Ceilings The Suspended Ceiling system is versatile and easy to install. Deep voids are easily created to hide services and the ceiling can be used to provide fire protection. Metal Components

More information

Architectural Specification Manual

Architectural Specification Manual Architectural Specification Manual SteelBuilt Curtainwall INFINITY System The SteelBuilt Curtainwall Infinity System can use as a back mullion almost any type of custom steel member, such as stainless

More information

CHAPTER 6 TYPES OF CONSTRUCTION

CHAPTER 6 TYPES OF CONSTRUCTION CHAPTER 6 TYPES OF CONSTRUCTION SECTION 61 GENERAL 61.1 Scope. The provisions of this chapter shall control the classification of buildings as to type of construction. SECTION 62 CONSTRUCTION CLASSIFICATION

More information

INTRODUCTION. We feel pleasure to introduce ourselves as manufacturers and suppliers of multifarious industrial storage systems and cable tray.

INTRODUCTION. We feel pleasure to introduce ourselves as manufacturers and suppliers of multifarious industrial storage systems and cable tray. T M MFG. & TRADING CORPORATION Super Market Display Rack, Wall Mounted Display System, Slotted Angle Steel Rack, Mezzanine Floor, Heavyduty Pallet Rack, library Stack Rack, Mobile Rack/Compactor, Plastic

More information

Structural vs Nonstructural Members. Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures

Structural vs Nonstructural Members. Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures Structural vs Nonstructural Members Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures Behavior of Cold-Formed Steel Members STEEL DESIGN SPECIFICATIONS Type of steel Specification

More information

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

R CODE CHANGE PROPOSAL FORM (See instructions on page 2) CODE CHANGE PROPOSAL FORM (See instructions on page 2) Code: IRC 12/13 Sections 301.2.2.2.1 Proponent: Charles S. Bajnai, Chesterfield County, VA, ICC Building Code Action Committee 1. Delete as shown

More information

Retain "Preinstallation Conference" Paragraph below if Work of this Section is extensive or complex enough to justify a conference.

Retain Preinstallation Conference Paragraph below if Work of this Section is extensive or complex enough to justify a conference. SECTION 05 40 00 - COLD-FORMED METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

LISTING INFORMATION OF ClarkDietrich Steel 'H' Stud and 'U' Track Fire-resistance-rated Area Separation Wall Assemblies SPEC ID: 26662

LISTING INFORMATION OF ClarkDietrich Steel 'H' Stud and 'U' Track Fire-resistance-rated Area Separation Wall Assemblies SPEC ID: 26662 LISTING INFORMATION OF ClarkDietrich Steel 'H' Stud and 'U' Track Fire-resistance-rated Area Separation Wall Assemblies SPEC ID: 26662 ClarkDietrich Building Systems 9100 Centre Pointe Drive, Suite 210

More information

SECTION OUTLET, PULL, AND JUNCTION BOXES

SECTION OUTLET, PULL, AND JUNCTION BOXES SECTION 16131 OUTLET, PULL, AND JUNCTION BOXES PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16112 - Raceways and Conduits. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:

More information

Series PV. Compact Switchgear Cabinets. Construction subject to change without notice Dimensions in mm

Series PV. Compact Switchgear Cabinets. Construction subject to change without notice Dimensions in mm Series PV Single layer design, thermal conductivity k = 5 W/m 2 K For wall mounting by hanging and standing installation Torsion resistant, self-supporting casing without joints, corrosion and seawater

More information

1. Interior gypsum wallboard. 2. Exterior gypsum board panels for ceilings and soffits. 3. Tile backing panels.

1. Interior gypsum wallboard. 2. Exterior gypsum board panels for ceilings and soffits. 3. Tile backing panels. SECTION 09260 - GYPSUM BOARD ASSEMBLIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS REPORT HOLDER: PANEL REY

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS REPORT HOLDER: PANEL REY 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-3752 Reissued 10/2015 This report is subject to renewal 10/2016. DIVISION: 09 00 00 FINISHES

More information

SECTION COLD-FORMED METAL FRAMING

SECTION COLD-FORMED METAL FRAMING SECTION 05400 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work of this Section shall include all materials and installation necessary to provide all cold formed metal framing. B. This Section includes:

More information

Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components

Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components Moduline Acoustic Enclosure System Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components Lab certified acoustic ratings Broad range of performance levels 63 Hz

More information

LATERAL DRIFT DESIGN IN COLD FORMED STEEL WALL SYSTEMS

LATERAL DRIFT DESIGN IN COLD FORMED STEEL WALL SYSTEMS 1 LATERAL DRIFT DESIGN IN COLD FORMED STEEL WALL SYSTEMS Thomas Castle, S.E. 2 This presentation is published by the Cold-Formed Steel Engineers Institute ( CFSEI ). The information herein shall not constitute

More information

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012) Gaines Charter Township 8555 Kalamazoo Ave SE Caledonia MI 49316 PH: 616 698-6640 Fax: 616 698-2490 www.gainestownship.org Building Department Statement of Special Inspections Michigan Building Code 2012

More information

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015 0 ICC ES Report ICC ES (800) 42 6587 (562) 699 054 www.icc es.orgg 000 Most Widely Accepted and Trusted ESR 2269 Reissued 02/205 This report is subject to renewal 02/207. DIVISION: 0 00 00 CONCRETE SECTION:

More information

MODEL: SIGHT-LINE- COMMAND CENTER CONSOLES

MODEL: SIGHT-LINE- COMMAND CENTER CONSOLES 2015 WINSTED CORPORATION 1) GENERAL DESCRIPTION 1.1 Sight-Line Command Center Consoles. SeeAppendix A - C for typical styles and measurements. 1.2 The contractor shall supply a system capable of supporting

More information

Smarter. Safer. Leaner.

Smarter. Safer. Leaner. Smarter. Safer. Leaner. Fast Installation and Removal Decrease Leading Edge Exposure by 87% OSHA Compliant Versatile and Reusable Use Perimeter Protection Posts During Construction: At Building Perimeter

More information

PROFESSIONAL ROLLING TOWER SYSTEMS

PROFESSIONAL ROLLING TOWER SYSTEMS Relax. It s an Altrex. ROLLING TOWER SYSTEMS Rolling tower Folding frame Relax. It s an Altrex. Working at height has several risks. Choosing Altrex is choosing safety, quality and durability. Altrex access

More information

A. Access doors and frames are part of an access door and frame allowance.

A. Access doors and frames are part of an access door and frame allowance. SECTION 08 31 13 ACCESS DOORS AND FRAMES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

ILKAclean Clean Room Systems

ILKAclean Clean Room Systems ILKAclean Clean Room Systems Systems for Ideas Cleanliness with System ILKAZELL Isoliertechnik GmbH Zwickau is your versatile expert when clean rooms are to meet unique demands. Thanks to the untiring

More information

A. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section

A. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section SECTION 15140 SUPPORTS, ANCHORS, AND SEALS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract including General and Supplementary Conditions, Division 1 Specification

More information

POST AND FRAME STRUCTURES (Pole Barns)

POST AND FRAME STRUCTURES (Pole Barns) POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:

More information

Advantages. - They are quick, clean and. sizes, floor types and construction systems mean the mezzanines can be adapted to meet specific client needs.

Advantages. - They are quick, clean and. sizes, floor types and construction systems mean the mezzanines can be adapted to meet specific client needs. Mezzanine Floors Mezzanine floors enable the working height of a space to be utilised to its full potential by doubling or tripling the surface area. They can be designed as storage areas, changing rooms

More information

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079) WET FILM ± 7.5 ± 5 Design No. CEJ 27 P (HI/JS 20-05) Table. CONCRETE FLOOR ASSEMBLY: Max. two-hour rated concrete floor assembly made from either lightweight or normal weight concrete with a density of 00-50 pcf, with a

More information

DRY CONSTRUCTION SYSTEMS

DRY CONSTRUCTION SYSTEMS DRY CONSTRUCTION SYSTEMS Adrienn LEPEL BUTE Dry construction systems Prefabricated elements assembly on site Minimal use of water dry construction systems Assembled partitions Suspended ceilings Raised

More information