a.: \ \ I I I I I \ \ \ \ \ \ \ \ (i) ~ = MechanicSt E-23/12 - T-90/12 Proposed River Crossing Lancaster, NH ""-- -,:)

Size: px
Start display at page:

Download "a.: \ \ I I I I I \ \ \ \ \ \ \ \ (i) ~ = MechanicSt E-23/12 - T-90/12 Proposed River Crossing Lancaster, NH ""-- -,:)"

Transcription

1 New Hampshire Optical Systems U New Hampshire Optical Systems, nc. 99 Pine Hill Rd. Nashua, NH 363 ( ) ~ G) -,:) - <. Q)... PROPOSED NHOS FBER OPTC CROSSNG N MechanicSt E T-912 W E 76' S (i) E T-NT12-1 ""-- ~ = a.: ~ 1 2-1" = 2' E T-NT12-2 Project # TD Primary 7 Drawing # AC-LANC-RV Mechanic St., Nearest cross street- Pleasant St. 1" = 5' Sheet 1 of 2 K: Pro jectsusnhdwgslancasterriver_xingtid-138tid-138.dwg

2 STE Notes: 1. The heights of structures shown hereon are based on field measurements taken with a Nikon 362 total station during a site survey on The horizontal distance between the nearest bridge edge and the existing overhead wires ranges from 5' to 8'. LOCUS MAP (Not to ) 3. Because of the close horizontal proximity to the existing bridge structure, the simplified drawing is submitted with vertical distances measured to the structure. This process simplifies the preparation and review of the crossing without jeopardizing its intent to protect the safe usage of the waterway 4. The smallest vertical distance from the top of existing bridge deck to the lowest existing overhead wires is 16'. 5. The vertical distance between the top of water and bridge deck is approximately 18'. 6. Vertical distances are representative of attachment heights after utility make ready moves are completed. Project # TD Primary 7 Drawing # AC-LANC-RV-2 Construction Notes: NHOS proposes to install a ¼ inch metal supporting strand between the existing utility poles shown above that will traverse the river. The strand will be installed at the proposed height (see above). The supporting strand will be secured to each pole using double dead end attachments to prevent any sag in the wire and maintain proper clearances. NHOS will lash a one inch diameter fiber optic cable (PVC jacket) to the strand using a dual lash method to provide security of the fiber over the right of way. The fiber will be tagged with twenty four hour contact information at each pole clamp. NHOS will employ the proper safety personnel during the crossing installation. The proposed install will meet all proper clearances from other Utilities. (see above). Additional pole guys will be added per NESC Rule 264 and as directed by pole owners. Mechanic St., Nearest cross street- Pleasant St. Sheet 2 of 2

3 New Hampshire Optical Systems New Hampshire Optical Systems, nc. 99 Pine Hill Rd. Nashua, NH 363 ( ).,. ~~ ~~ fbt '"< PROPOSED NHOS FBER OPTC CROSSNG N W E S ' 2 1" = 2' " = 5' 1 Project # TD-14 - Primary 7 Drawing # AC-JEF-RV-1 '' '' ' Presidential Highway, Nearest cross street- Turnpike Rd. Sheet 1 of 2 K:ProjectsUSNHdwgsJeffersonriver...xlng11D-1411D-14.dwg

4 STE Notes: 1. The heights of structures shown hereon are based on field measurements taken with a Nikon 362 total station during a site survey on The horizontal distance between the nearest bridge edge and the existing overhead wires ranges from 75' to 78'. LOCUS MAP (Not to ) 3. The smallest vertical distance from the top of existing bridge deck to the lowest existing overhead wires is 5'. 4. The vertical distance between the top of water and bridge deck is approximately 36'. 5. The waterway is classified as not suitable for sail boating and per NESC Table a vertical clearance of 14' must be maintained between the lowest conductor and 1 year floodplain. 6. Based on the FEMA Flood nsurance Rate map 1-16 (Community number 3333C) Effective April 16, 1986, there is no 1 year, or 1 year, flood event information currently available for this area. 7. Vertical distances are representative of attachment heights after utility make ready moves are completed. Project # TD-14 - Primary 7 Drawing # AC-JEF-RV-1 Construction Notes: NHOS proposes to install a ¼ inch metal supporting strand between the existing utility poles shown above that will traverse the river. The strand will be installed at the proposed height (see above). The supporting strand will be secured to each pole using double dead end attachments to prevent any sag in the wire and maintain proper clearances. NHOS will lash a one inch diameter fiber optic cable (PVC jacket) to the strand using a dual lash method to provide security of the fiber over the right of way. The fiber will be tagged with twenty four hour contact information at each pole clamp. NHOS will employ the proper safety personnel during the crossing installation. The proposed install will meet all proper clearances from other Utilities. (see above). Additional pole guys will be added per NESC Rule 264 and as directed by pole owners. Presidential Highway, Nearest cross street- Turnpike Rd. Sheet 2 of 2

5 MAROS AV MAROS AV HAMLN AV SPRU N MAN ST W E CROSS ST SPRUCE ST PNE ST Moose Brook MAN ST S MCLEOD ST 1 2 MAN ST Project # TD Primary 7 Drawing # Engineering AC-GOR-RV " = 2' US 2 US KEENAN ST MASON HLL LARY ST 1" = 5' Main St., Nearest cross street- Spruce St. Sheet 1 of 2

6 STE LOCUS MAP (Not to ) Notes: 1. The heights of structures shown hereon are based on field measurements taken with a Nikon 362 total station during a site survey on The horizontal distance between the nearest bridge edge and the existing overhead wires is approximately 1' or less. 3. Because of the close horizontal proximity to the existing bridge structure, the simplified drawing is submitted with vertical distances measured to the structure. This process simplifies the preparation and review of the crossing without jeopardizing its intent to protect the safe usage of the waterway 4. The smallest vertical distance from the top of existing bridge deck to the lowest existing overhead wires is 17'. 5. The vertical distance between the top of water and bridge deck is approximately 9'. 6. Vertical distances are representative of attachment heights after utility make ready moves are completed. Project # TD Primary 7 Drawing # Engineering AC-GOR-RV-1 Construction Notes: NHOS proposes to install a ¼ inch metal supporting strand between the existing utility poles shown above that will traverse the river. The strand will be installed at the proposed height (see above). The supporting strand will be secured to each pole using double dead end attachments to prevent any sag in the wire and maintain proper clearances. NHOS will lash a one inch diameter fiber optic cable (PVC jacket) to the strand using a dual lash method to provide security of the fiber over the right of way. The fiber will be tagged with twenty four hour contact information at each pole clamp. NHOS will employ the proper safety personnel during the crossing installation. The proposed install will meet all proper clearances from other Utilities. (see above). Additional pole guys will be added per NESC Rule 264 and as directed by pole owners. 1 Main St., Nearest cross street- Spruce St. Sheet 2 of 2

Peabody River. White Mtn. Rd. Route 16. Proposed River Crossing Gorham, NH. Peabody River WHITE BIRCH LN. Mt. Carter Dr.

Peabody River. White Mtn. Rd. Route 16. Proposed River Crossing Gorham, NH. Peabody River WHITE BIRCH LN. Mt. Carter Dr. Gorham, NH WHITE BIRCH LN Peabody River Mt. Carter Dr. White Mtn. Rd. Route 16 Peabody River White Mtn. Rd. Route 16 W N S Project # TID-157 - Primary 10 Drawing # AC-GOR-RIV-4 E Date: 11/28/11 Gorham,

More information

Proposed Stream Crossing Franklin, NH. Scale 1" = 200' Scale 1" = 50' Project #TID-11 - Primary 15 Drawing #AC-FRA-RIV-1. Date 01/25/12 Revision # 1

Proposed Stream Crossing Franklin, NH. Scale 1 = 200' Scale 1 = 50' Project #TID-11 - Primary 15 Drawing #AC-FRA-RIV-1. Date 01/25/12 Revision # 1 N W E S Project #TID-11 - Primary 15 Drawing #AC-FRA-RIV-1 Date 01/25/12 100 0 200 25 0 50 Proposed Stream Crossing Franklin, NH 1" = 200' 1" = 50' Central St, Franklin NH Nearest cross street-peabody

More information

Proposed Railroad Crossing Lancaster, NH

Proposed Railroad Crossing Lancaster, NH N W E S Project # TID-304 - Primary 16 Drawing # AR-LAN-RR-1 Date: 04/24/12 100 0 200 1" = 200' 25 0 50 1" = 50' Route 3 (Lancaster Rd.), Nearest cross street- Industrial Park Dr. Sheet 1 of 2 SITE LOCUS

More information

THE STATE OF NEW HAMPSHIRE BEFORE THE PUBLIC UTILITIES COMMISSION

THE STATE OF NEW HAMPSHIRE BEFORE THE PUBLIC UTILITIES COMMISSION THE STATE OF NEW HAMPSHIRE BEFORE THE PUBLIC UTILITIES COMMISSION PETITION OF PUBLIC SERVICE COMPANY OF NEW HAMPSHIRE FOR A LICENSE TO CONSTRUCT AND MAINTAIN ELECTRIC LINES, STATIC WIRES AND FIBER OPTIC

More information

ATTACHMENT 13 NORTHEAST-POCONO RELIABILITY PROJECT PPL DESIGN CRITERIA AND SAFETY PRACTICES

ATTACHMENT 13 NORTHEAST-POCONO RELIABILITY PROJECT PPL DESIGN CRITERIA AND SAFETY PRACTICES ATTACHMENT 13 NORTHEAST-POCONO RELIABILITY PROJECT PPL DESIGN CRITERIA AND SAFETY PRACTICES The National Electrical Safety Code (NESC) is a set of rules to safeguard people during the installation, operation,

More information

STATE OF NEW HAMPSHIRE Inter-Department Communication. Tf~ Tom Frantz - Director, Electric Division

STATE OF NEW HAMPSHIRE Inter-Department Communication. Tf~ Tom Frantz - Director, Electric Division STATE OF NEW HAMPSHIRE Inter-Department Communication FROM: \"""' Tf~ Tom Frantz - Director, Electric Division DATE: 15 October 2010 AT (OFFICE): NHPUC SUBJECT: DE 10-224: Petition by PSNH for a License

More information

Interpretation. Section 23. Clearances

Interpretation. Section 23. Clearances Interpretation Section 23. Clearances Rule 232.A. Table 1 Vertical clearance of wires above ground or rails Basic clearances Minimum vertical clearance of wires above ground or rails (1961, 6th Edition;

More information

APPENDIX E DISTRIBUTION LINE MINIMUM DESIGN REVIEW INFORMATION AND SUGGESTED WORKSHEET

APPENDIX E DISTRIBUTION LINE MINIMUM DESIGN REVIEW INFORMATION AND SUGGESTED WORKSHEET APPENDIX E DISTRIBUTION LINE MINIMUM DESIGN REVIEW INFORMATION AND SUGGESTED WORKSHEET The following guidelines are provided, and corresponding information must be submitted with each Permit application

More information

RESIDENTIAL QUICK REFERENCE

RESIDENTIAL QUICK REFERENCE RESIDENTIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR

More information

Grant PUD. Joint Use Standards. For Pole Attachments including: Cable Television Fiber Optics Telecommunications

Grant PUD. Joint Use Standards. For Pole Attachments including: Cable Television Fiber Optics Telecommunications Grant PUD Joint Use Standards For Pole Attachments including: Cable Television Fiber Optics Telecommunications REVISED: July 25, 2018 INTRODUCTION AND OVERVIEW The information contained in these Joint

More information

SECTION 200 CLEARANCES

SECTION 200 CLEARANCES SECTION 200 CLEARANCES 200.01 Texas Law & OSHA Regulations To ensure safety and the protection of the public, Chapter 752 of the Texas Health and Safety Code makes it unlawful for unauthorized persons

More information

APPLICATION FOR PIPE OR WIRE OCCUPANCY

APPLICATION FOR PIPE OR WIRE OCCUPANCY APPLICATION FOR PIPE OR WIRE OCCUPANCY Please answer all questions and direct cover letter / project description, completed application, application fee, and three (3) copies of project plans to: AECOM

More information

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL WARNING Before digging or trenching... Call 811 Indiana Underground Protection Service 1-800-382-5544 AVOID BURIED POWER CABLES 4901 East Park 30 Drive P.O.

More information

Joint Use. Guidelines and Construction Standards

Joint Use. Guidelines and Construction Standards Joint Use Guidelines and Construction Standards July 7, 2017 Table of Contents Page Definitions...3 Purpose and Scope...5 General Requirements...6 Joint Use Attachment Application Process...9 Pole Attachment

More information

Underground Conduit Systems

Underground Conduit Systems Section 32 Underground Conduit Systems Note 1 under the title of Sec. 32 defines how the NESC uses the following terms: Duct Conduit Conduit system The common trade use of these terms is slightly different

More information

Summary of Major 1997 NESC Changes

Summary of Major 1997 NESC Changes Summary of Major 1997 NESC Changes Rule Description of Changes 012C Clarification. It was made more clear that good practice must be applied for these expected conditions that are known at the time of

More information

SECTION 5 CLEARANCES. Unless otherwise noted, all clearances are from surface-to-surface and all distances are measured center-to-center.

SECTION 5 CLEARANCES. Unless otherwise noted, all clearances are from surface-to-surface and all distances are measured center-to-center. SECTION 5 The electric line clearances shown in Tables 5-1 are required for buildings, structures, and surfaces to comply with requirements of the National Electric Safety Code, the Wisconsin Administrative

More information

Electric Service Handbook

Electric Service Handbook Electric Service Handbook Revised August 2017 Contact Information Telephone (253): Electrical Inspection Office 502-8277 7:30 am - 4:30 pm Electrical Inspectors Area Map on Website 7:30 am - 8:30 am Automated

More information

ANY SPECIFICATION DRAWINGS OR DATED PRIOR TO SEPTEMBER 2015 WILL NOT BE HONORED.

ANY SPECIFICATION DRAWINGS OR DATED PRIOR TO SEPTEMBER 2015 WILL NOT BE HONORED. November 30, 2015 Dear STEMC Member and Contractors, Over the years, STEMC has made many changes to its member requirements for new services and specifications associated with those requirements. As a

More information

TS 804 CABLES TABLE OF CONTENTS TRAFFIC SIGNAL EQUIPMENT POLE WIRING DIAGRAM LOCATIONS WITH CENTRE MEDIANS

TS 804 CABLES TABLE OF CONTENTS TRAFFIC SIGNAL EQUIPMENT POLE WIRING DIAGRAM LOCATIONS WITH CENTRE MEDIANS TORONTO TRANSPORTATION January 2012 TS 804 CABLES TABLE OF CONTENTS 1. DRAWINGS TTD 804.001 TTD 804.002 TTD 804.003 TTD 804.005 TTD 804.006 TTD 804.007 TTD 804.010 TTD 804.015 TTD 804.020 TTD 804.025 TTD

More information

Basic Service. This Section provides information regarding a. Introduction

Basic Service. This Section provides information regarding a. Introduction Basic Service Introduction This Section provides information regarding a new electric Basic Service for a single phase service less than or equal to 400 amps, and a three phase service less than 50kW.

More information

An altered service that is moved, upgraded (ex., 200 to 400 amp) or changed to meet today's standards for electric service.

An altered service that is moved, upgraded (ex., 200 to 400 amp) or changed to meet today's standards for electric service. ALTERED SERVICE An altered service that is moved, upgraded (ex., 200 to 400 amp) or changed to meet today's standards for electric service. Customer Responsibilities Provide, install and maintain all required

More information

TEMPORARY FACILITIES

TEMPORARY FACILITIES MUNICIPAL LIGHT & POWER & CHUGACH ELECTRIC ASSOCIATION ELECTRIC SERVICE REQUIREMENTS EXCERPT TEMPORARY FACILITIES 2015 EDITION Effective August 3, 2015 This is an EXCERPT; the complete book is available

More information

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11 Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11 Underground Residential Distribution (URD) Index General Discussion... 1-2 Description... 3-7 Drawings (Available

More information

ELECTRICAL SERVICE UPGRADE RESIDENTIAL AND COMMERCIAL QUICK INFORMATION REFERENCE

ELECTRICAL SERVICE UPGRADE RESIDENTIAL AND COMMERCIAL QUICK INFORMATION REFERENCE ELECTRICAL SERVICE UPGRADE RESIDENTIAL AND COMMERCIAL QUICK INFORMATION REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2015 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION.

More information

Ameren Illinois Electric Quality Assurance Program Keith Lowry Superintendent, Electric Quality Assurance

Ameren Illinois Electric Quality Assurance Program Keith Lowry Superintendent, Electric Quality Assurance Ameren Illinois Electric Quality Assurance Program Keith Lowry Superintendent, Electric Quality Assurance May 15, 2015 Development of Quality Assurance Process Illinois Commerce Commission Reliability

More information

Indianapolis Power & Light Company

Indianapolis Power & Light Company Indianapolis Power & Light Company Electric Service and Meter Manual The Electric Service & Meter Manual is not copyrighted and permission is hereby given to reproduce this document. However, the Indianapolis

More information

UNITED COOPERATIVE SERVICES. SPECIFICATIONS FOR SELF-CONTAINED METER INSTALLATIONS August 2014

UNITED COOPERATIVE SERVICES. SPECIFICATIONS FOR SELF-CONTAINED METER INSTALLATIONS August 2014 UNITED COOPERATIVE SERVICES SPECIFICATIONS FOR SELF-CONTAINED METER INSTALLATIONS August 2014 A member may obtain a new, single phase service from the Cooperative by providing or purchasing a meter loop.

More information

OVERHEAD SERVICES - RESIDENTIAL & GENERAL SERVICE. See Chapter 3, Section 3.01 for more information about point of entrance (POE).

OVERHEAD SERVICES - RESIDENTIAL & GENERAL SERVICE. See Chapter 3, Section 3.01 for more information about point of entrance (POE). 6.01 GENERAL OVERHEAD SERVICES - RESIDENTIAL & GENERAL SERVICE See Chapter 3, Section 3.01 for more information about point of entrance (POE). In all cases, the customer installs, owns, and maintains the

More information

Homework 3 Perspectives on the Evolution of Structures (Analysis 2 and GWB Study) George Washington Bridge Structural Study and Analysis

Homework 3 Perspectives on the Evolution of Structures (Analysis 2 and GWB Study) George Washington Bridge Structural Study and Analysis Homework 3 Perspectives on the Evolution of Structures (Analysis 2 and GWB Study) George Washington Bridge Structural Study and Analysis In this assignment you will learn how to calculate the force in

More information

OVERHEAD SERVICE. Table of Contents - Section 400

OVERHEAD SERVICE. Table of Contents - Section 400 OVERHEAD SERVICE Table of Contents - Section 400 PARAGRAPH 400.0 OVERHEAD SERVICES (0-600 VOLTS)... 1 400.1 GENERAL 1 400.2 IDENTIFICATION OF CONDUCTORS. 1 400.3 MAXIMUM SERVICE ENTRANCE CONDUCTOR SIZE

More information

Specifications for Residential Overhead Electric Service Installation

Specifications for Residential Overhead Electric Service Installation Specifications for Residential Overhead Electric Service Installation This brochure addresses most typical residential overhead service installations. Variances for the following specifications must be

More information

NESC Subcommittee 5 Changes to the 2017 NESC. Joseph Rempe 18 October 2016

NESC Subcommittee 5 Changes to the 2017 NESC. Joseph Rempe 18 October 2016 NESC Subcommittee 5 Changes to the 2017 NESC Joseph Rempe 18 October 2016 Re-format Rule 241.C. At Crossings 241. Application of grades of construction to different situations 2012 version 2 Re-format

More information

Post Office Box 500 Carson, WA Phone (509) Fax (509) Toll Free (800)

Post Office Box 500 Carson, WA Phone (509) Fax (509) Toll Free (800) Public Utility District No. 1 of Skamania County Post Office Box 500 Carson, WA 98610 Phone (509) 427-5126 Fax (509) 427-8416 Toll Free (800) 922-5329 ELECTRIC LINE EXTENSION If you are purchasing property

More information

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL WARNING Before digging or trenching... Call Indiana Underground Protection Service 1-800-382-5544 AVOID BURIED POWER CABLES CONTENTS Page # 100-200 OR 400 AMP

More information

For the 2008 Code, the minimum clear distances were revised to reflect an accurate metric conversion (also known as a soft conversion).

For the 2008 Code, the minimum clear distances were revised to reflect an accurate metric conversion (also known as a soft conversion). II. 600 Volts, Nominal, or Less 110.26 Spaces About Electrical Equipment. Sufficient access and working space shall be provided and maintained about all electrical equipment to permit ready and safe operation

More information

Residential Electric Policy

Residential Electric Policy Residential Electric Policy 7/19/16 1 Table of Contents General Information..3 Construction.3 Ownership....3 Underground Service...3 Apartments/Multi-Unit Dwellings..3 Modular and Manufactured Homes...3

More information

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Color Light Stream Lighted Rain Waterfall Installation Manual Part number Description CLSRW24-8 Color Light Stream Lighted Rain Waterfall 24 CLSRW36-8 Color Light Stream Lighted Rain Waterfall 36 CLSRW48-8

More information

Strength & Loading. Of Wood Utility Poles. Webinar

Strength & Loading. Of Wood Utility Poles. Webinar Strength & Loading Of Wood Utility Poles. Webinar Overview Benefits of Wood as a Utility Pole Material Defining Wood Pole Strength Loading Criteria In-Service Analysis Upcoming NESC 2017 Changes Pole Material

More information

General Symbols, Ducts and Cables

General Symbols, Ducts and Cables DIVISION 2000 ABBREVIATIONS 2009 11 2000.001 0 Abbreviations, General 2009 11 2011.101 0 General Symbols, Ducts and Cables 2009 11 2011.201 0 General Symbols, Maintenance Holes, Junction Boxes, Pads, and

More information

General Symbols, Ducts and Cables

General Symbols, Ducts and Cables DIVISION 2000 - ABBREVIATIONS 2009 11 2000.001 0 Abbreviations, General 2009 11 2011.101 0 General Symbols, Ducts and Cables 2009 11 2011.201 0 General Symbols, Maintenance Holes, Junction Boxes, Pads,

More information

TECHNICAL SPECIFICATIONS LAYING OF DIFFERENT WIRES & CABLES MOUNTED ON POLES FOR BRPL/BYPL

TECHNICAL SPECIFICATIONS LAYING OF DIFFERENT WIRES & CABLES MOUNTED ON POLES FOR BRPL/BYPL TECHNICAL SPECIFICATIONS OF LAYING OF DIFFERENT WIRES & CABLES MOUNTED ON POLES FOR BRPL/BYPL SPECIFICATION NO- GN101-03-SP-13-02 INDEX 1.0 SCOPE 4 2.0 DESIGN..4 3.0 REQUIREMENT...5 4.0 DESIGN ( DISTRIBUTION

More information

TEMPORARY METER POLE INSTALLATION

TEMPORARY METER POLE INSTALLATION TEMPARY METER POLE INSTALLATION MEMBER PROVIDED Location to be made by REMC within 50' of our transformer or existing service Temporary pole to be properly braced 24" 3 wire weatherhead (located 24" from

More information

General Symbols, Ducts and Cables

General Symbols, Ducts and Cables MUNICIPAL AND COMMON DIVISION 2000 ABBREVIATIONS 2009 11 2000.001 0 Abbreviations, General 2009 11 2011.101 0 General Symbols, Ducts and Cables 2009 11 2011.201 0 General Symbols, Maintenance Holes, Junction

More information

Douglas County Traffic Signal Installation Guidelines (January 2013)

Douglas County Traffic Signal Installation Guidelines (January 2013) Douglas County Traffic Signal Installation Guidelines (January 2013) The following guidelines are minimum requirements for equipment installation. Section A. Poles and Foundations ( Wood, Concrete, Mast

More information

EXCERPTS OF MERALCO GUIDELINES FOR CUSTOMER-OWNED POLES

EXCERPTS OF MERALCO GUIDELINES FOR CUSTOMER-OWNED POLES EXCERPTS OF MERALCO GUIDELINES FOR CUSTOMER-OWNED POLES Introduction This is a general overview of the policies, standards and guidelines of Meralco s existing Service Standards on Customer-Owned Poles.

More information

DESIGN & CONSTRUCTION STANDARD SPECIFICATIONS. Wireline Occupancies

DESIGN & CONSTRUCTION STANDARD SPECIFICATIONS. Wireline Occupancies DESIGN & CONSTRUCTION STANDARD SPECIFICATIONS Wireline Occupancies OFFICE OF: VICE PRESIDENT ENGINEERING JACKSONVILLE, FLORIDA ISSUED: September 15, 2003 REVISED: December 16, 2016 THIS PAGE BLANK DESIGN

More information

Applying for a Kinder Morgan Cochin Canada / UTOPIA Canada Proximity & Crossing Permit. Design and Construction Guidelines

Applying for a Kinder Morgan Cochin Canada / UTOPIA Canada Proximity & Crossing Permit. Design and Construction Guidelines Applying for a Kinder Morgan Cochin Canada / UTOPIA Canada Proximity & Crossing Permit Design and Construction Guidelines A Guide to Applying for a Kinder Morgan Cochin Canada / UTOPIA Canada Proximity

More information

Dynamic Analysis of Transmission Tower

Dynamic Analysis of Transmission Tower Dynamic Analysis of Transmission Tower Sk.Musthafa Department of Civil Engineering, Amara Institute of Engineering and Technology. Sk.Yusuf Basha Department of Civil Engineering, Amara Institute of Engineering

More information

Garland Power & Light

Garland Power & Light Garland Power & Light Pole Attachment Guidelines and Procedures Updated: October 11, 2017 Page 1 of 59 Table of Contents Section 1 - Purpose... 3 Section 2 - Pole Attachment Terminology... 5 Section 3

More information

SECTION 4 - SECONDARY CONSTRUCTION OVERHEAD TABLE OF CONTENTS

SECTION 4 - SECONDARY CONSTRUCTION OVERHEAD TABLE OF CONTENTS 4. GENERAL SECONDARIES & SERVICES 4.- INDIVIDUAL PHASE SECONDARY OVERHEAD LINE EXTENSIONS 4.- SECONDARY AND SERVICE CABLE SPLICES 4.- INSULATED SERVICE ENTRANCE COMPRESSION CONNECTORS 4.- 4. POLE ATTACHMENTS

More information

PRIMARY LINE EXTENSION

PRIMARY LINE EXTENSION PRIMARY LINE EXTENSION Installation of new electric service to an empty parcel/lot or extending a transformer to within 150' of proposed meter location. This includes installing a permanent branch, addition,

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. AFC Cable Systems, Inc. Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519.13 METAL CLAD CABLE-MC

More information

New Construction Units. a. Includes the furnishing of all labor and equipment for the installation of new construction units.

New Construction Units. a. Includes the furnishing of all labor and equipment for the installation of new construction units. 1 All construction is to follow design and construction documents approved by the Engineer and marked approved for construction. All construction shall also follow the National Electrical Safety Code,

More information

ISO Rules Part 500, Facilities Division 502, Technical Requirements Section Bulk Transmission Technical Requirements

ISO Rules Part 500, Facilities Division 502, Technical Requirements Section Bulk Transmission Technical Requirements Part 500, Facilities Division 502, Technical Requirements Section 502.2 Bulk Transmission Technical Requirements Applicability 1 This section 502.2 applies to: Requirements the legal owner of any bulk

More information

NESC 2017 Changes Subcommittee 4 Clearances

NESC 2017 Changes Subcommittee 4 Clearances NESC 2017 Changes Subcommittee 4 Clearances NESC Workshop San Antonio October 11, 2016 Eric Engdahl Chairman SC4 Mickey Gunter Secretary SC4 Sub-Committee 4 SC4 Development of the NESC 2017 ¾310 Change

More information

MOTI -- Five Strand Barbed Wire & Paige Wire Fence Specifications

MOTI -- Five Strand Barbed Wire & Paige Wire Fence Specifications MOTI -- Five Strand Barbed Wire & Paige Wire Fence Specifications SCHEDULE 8 (and attached drawings) FIVE STRAND BARBED-WIRE FENCE SPECIFICATIONS Rocky Mountain District General If equipment is used at

More information

Electrical Service Guidelines

Electrical Service Guidelines Electrical Service Guidelines Middle Tennessee Electric Membership Corporation Revised: Feb 9, 2018 2/9/2018 MTEMC's Electrical Service Guidelines TABLE OF CONTENTS Right-of-Way Clearance Guide 4 MTEMC

More information

SMALL CELL DESIGN GUIDELINES

SMALL CELL DESIGN GUIDELINES Section 1: Collocations on Existing Wireless Support Structures (Type I and II Requests) 1.1 Collocations Encouraged. The collocation of wireless facilities on existing support structures engineered to

More information

Duke Energy Carolinas Distribution Construction Standards Reference Guide

Duke Energy Carolinas Distribution Construction Standards Reference Guide Duke Energy Carolinas Distribution Construction Standards Reference Guide The Duke Energy Carolinas (DEC) Distribution Construction Standards are available on the My Duke Energy Contractor Portal. Access

More information

Central Lincoln PUD Single-Family Residential Guidelines & Standards April 21, 2017

Central Lincoln PUD Single-Family Residential Guidelines & Standards April 21, 2017 Central Lincoln PUD Single-Family Residential Guidelines & Standards April 21, 2017 Overview of Hook-Up Procedures: The following is a general outline of how you get a new electrical service for a single-family

More information

V. Design, Application, Maintenance & Operation Technical Requirements

V. Design, Application, Maintenance & Operation Technical Requirements V. Design, Application, Maintenance & Operation Technical Requirements V.A PJM Design & Application of Overhead Transmission Lines 69 kv & Above These design criteria have been established to assure acceptable

More information

Homework 3 Perspectives on the Evolution of Structures (Analysis 2 and GWB Study) George Washington Bridge Structural Study and Analysis

Homework 3 Perspectives on the Evolution of Structures (Analysis 2 and GWB Study) George Washington Bridge Structural Study and Analysis Homework 3 Perspectives on the Evolution of Structures (Analysis 2 and GWB Study) George Washington Bridge Structural Study and Analysis In this assignment you will learn how to calculate the force and

More information

CHAPTER 12 INSTALLATION OF UTILITIES AND OTHER SYSTEMS TABLE OF CONTENTS

CHAPTER 12 INSTALLATION OF UTILITIES AND OTHER SYSTEMS TABLE OF CONTENTS CHAPTER 12 INSTALLATION OF UTILITIES AND OTHER SYSTEMS TABLE OF CONTENTS Section Title Page 12.1 General... 12-1 12.2 Design Standards... 12-1 12.2.1 General Requirements...12-1 12.2.2 Minimum Depth...12-1

More information

New Conduit Specification

New Conduit Specification New Conduit Specification Combines Portions of Sections 715, 783 & 992 into New Section 630. Coordinated Effort Between Traffic Operations, ITS, Lighting, Construction, and Industry New Conduit Specification

More information

ELECTRICAL SAFETY Information Bulletin

ELECTRICAL SAFETY Information Bulletin ELECTRICAL SAFETY Information Bulletin March 2014 CEC-12 [rev-6] Page 1 of 6 CANADIAN ELECTRICAL CODE SUBJECT: Section 12 Wiring Methods Conductors General Insulation Thickness on Conductors Used in Ungrounded

More information

ANCHORAGE MUNICIPAL LIGHT & POWER ENGINEERING DIVISION

ANCHORAGE MUNICIPAL LIGHT & POWER ENGINEERING DIVISION ANCHORAGE MUNICIPAL LIGHT & POWER ENGINEERING DIVISION ML&P ELECTRICAL FACILITY CLEARANCE REQUIREMENTS FOR CONSTRUCTION OR MAINTENANCE NEAR ELECTRICAL FACILITIES July 31, 2014 MUNICIPAL LIGHT & POWER ELECTRICAL

More information

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION SECTION 74 AIRPORT OBSTRUCTION LIGHTS (FAA L-119) 74-1 GENERAL The Contractor shall perform all work required by the plans and specifications for construction of obstruction lights in accordance with the

More information

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings November 2017 contents General Information... 3

More information

Please check with your local inspection authority for any additional requirements before installation.

Please check with your local inspection authority for any additional requirements before installation. Specifications for Residential Underground Electric Service Installation This brochure addresses most typical residential underground service installations. Variances for the following specifications must

More information

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service.

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service. CHAPTER3 Clark Public Utilities Commercial Electric Service Handbook Commercial Underground Services Preparing for the installation The following checklist will assist in preparing a project for the installation

More information

WIRING METHODS CHAPTER 38

WIRING METHODS CHAPTER 38 CHAPTER 38 WIRING METHODS SECTION E3801 GENERAL REQUIREMENTS E3801.1 Scope. This chapter covers the wiring methods for services, feeders and branch circuits for electrical power and distribution. E3801.2

More information

JHU Department of Civil Engineering : Perspectives on the Evolution of Structures

JHU Department of Civil Engineering : Perspectives on the Evolution of Structures JHU Department of Civil Engineering 560.141: Perspectives on the Evolution of Structures Spring 2005 Homework #4: The George Washington Bridge Due in class on Tuesday March 29th Your task in this assignment

More information

Kissimmee Utility Authority Storm Hardening Report to the Florida Public Service Commission Pursuant to Rule , F.A.C.

Kissimmee Utility Authority Storm Hardening Report to the Florida Public Service Commission Pursuant to Rule , F.A.C. Kissimmee Utility Authority Storm Hardening Report to the Florida Public Service Commission Pursuant to Rule 25-6.0343, F.A.C. 1) Introduction This report is filed in response to the above referenced rule

More information

EGRESS CHAPTER ,500 3 Over 2,500 4 OCCUPANT LOAD REQUIRED MEANS OF EGRESS

EGRESS CHAPTER ,500 3 Over 2,500 4 OCCUPANT LOAD REQUIRED MEANS OF EGRESS CHAPTER 4 EGRESS SECTION 401 GENERAL 401.1 General. The means of egress for new bleachers, folding and telescopic seating, and grandstands shall comply with this chapter. SECTION 402 TRAVEL 402.1 Exit

More information

Fracture Critical Bridge Inspection. Presented by MN/DOT Bridge Safety Inspections

Fracture Critical Bridge Inspection. Presented by MN/DOT Bridge Safety Inspections Fracture Critical Bridge Inspection Presented by MN/DOT Bridge Safety Inspections MN/DOT s s fracture critical bridge inspection team performs in-depth and special inspections for State, County and City

More information

Wood Decks. Please call for further information. Municipality of Roblin Planning Department st Ave. NW Roblin, Manitoba R0L 1P0

Wood Decks. Please call for further information. Municipality of Roblin Planning Department st Ave. NW Roblin, Manitoba R0L 1P0 Every effort has been made to ensure the accuracy of the information contained in this pamphlet. However, in case of a discrepancy between this pamphlet and the respective By-laws, the By-law will take

More information

MIPSYCON Duane Phillips Stanley Consultants, Inc.

MIPSYCON Duane Phillips Stanley Consultants, Inc. MIPSYCON 2014 Duane Phillips Stanley Consultants, Inc. Presentation of process and design considerations associated with design & engineering of long spans on transmission lines. Basis: 2700 ft crossing

More information

Building Attachments and Services

Building Attachments and Services Part Four. Other Electrical Procedures CHAPTER 11 Building Attachments and Services All electrical energy supplied to power-consuming devices and appliances within a building must pass through the electrical

More information

CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION

CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 604 NOVEMBER 2004 CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION TABLE OF CONTENTS 604.01 SCOPE 604.02 REFERENCES 604.03 DEFINITIONS - Not Used

More information

Title Transmission Line Maintenance Standards. Reference Number PMP 17 - (RIC Standard: EP SP)

Title Transmission Line Maintenance Standards. Reference Number PMP 17 - (RIC Standard: EP SP) Discipline Engineering Standard - NSW Category Electrical Title Reference Number PMP 17 - (RIC Standard: EP 10 01 00 02 SP) Document Control Status Date Prepared Reviewed Endorsed Approved Mar 05 Standards

More information

From the ADA and ABA Accessibility Guidelines for Buildings and Facilities

From the ADA and ABA Accessibility Guidelines for Buildings and Facilities From the ADA and ABA Accessibility Guidelines for Buildings and Facilities Published in the Federal Register on July 23, 2004 1003 Recreational Boating Facilities 1003.1 General. Recreational boating facilities

More information

1) Introduction. a) Name of city/utility: City of Jacksonville Beach, Florida/dba Beaches Energy Services

1) Introduction. a) Name of city/utility: City of Jacksonville Beach, Florida/dba Beaches Energy Services City of Jacksonville Beach, Florida dba/beaches Energy Services Report to the Florida Public Service Commission Pursuant to Rule 25-6.0343, F.A.C. Calendar Year 2014 1) Introduction a) Name of city/utility:

More information

GENERAL NOTES PEDERNALES ELECTRIC COOPERATIVE, INC. RESIDENTIAL AND COMMERCIAL AMP METER LOOP SPECIFICATIONS

GENERAL NOTES PEDERNALES ELECTRIC COOPERATIVE, INC. RESIDENTIAL AND COMMERCIAL AMP METER LOOP SPECIFICATIONS GENERAL NOTES 1. Residential and commercial meter loops are typically used when constructing facilities for permanent service. It is important that all guidelines outlined in this document be followed

More information

SPECIFICATION. for LOCAL DISTRIBUTION LINE CLEARANCE. TREE WORK and BRUSH CONTROL

SPECIFICATION. for LOCAL DISTRIBUTION LINE CLEARANCE. TREE WORK and BRUSH CONTROL SPECIFICATION for LOCAL DISTRIBUTION LINE CLEARANCE TREE WORK and BRUSH CONTROL Revision 2014-B Table of Contents Section Page Number General Requirements... 1 Scope of Work... 2 Scheduled Maintenance

More information

(Condensed from National Electric Code)

(Condensed from National Electric Code) WIRING, SPECIFICATIONS, INSPECTION, AND METER INSTALLATION PROCEDURES FOR RESIDENTIAL CUSTOMERS SERVED BY SOUTHWEST ARKANSAS ELECTRIC COOPERATIVE CORPORATION Effective April 1, 1974 Revised February 3,

More information

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4. 6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4. 6.2 OVERHEAD SERVICES Wiring of any premises for connection

More information

FLAMABILITY TESTS FOR ELECTRICAL CABLES

FLAMABILITY TESTS FOR ELECTRICAL CABLES Tests on electric and optical fibre cables under fire conditions Description E 60332-1-2 E 60332-2-2 acc. to IEC 60332-1-2 acc. to IEC 60332-2-2 Tests for flame Tests for flame propagation for a single

More information

2 FINDING OF THE POTENTIAL SITES

2 FINDING OF THE POTENTIAL SITES EXECUTIVE SUMMARY 1 Background S-1 2 User of Manual S-1 3 Applicable Range of Micro-hydro power in the Indonesia S-2 4 How to use this Manual S-2 Chapter 1 INTRODUCTION 1-1 1.1 Purpose of the Manual

More information

Good Practice Guide. Technical Guidance: Flood risk activity exemptions Date Published: April GPG 221 Document Owner: Flood Risk Strategy

Good Practice Guide. Technical Guidance: Flood risk activity exemptions Date Published: April GPG 221 Document Owner: Flood Risk Strategy Good Practice Guide Technical Guidance: Flood risk activity exemptions Date Published: April 2016 GPG 221 Document Owner: Flood Risk Strategy Page 1 of 41 Version History: Document Date Summary of Changes

More information

Signage Code. H101.2 Signs exempt from permits. The following signs are exempt from the requirements to obtain a permit before erection:

Signage Code. H101.2 Signs exempt from permits. The following signs are exempt from the requirements to obtain a permit before erection: Signage Code ICC Code: Appendix H: Signs SECTION H101 GENERAL H101.1 General. A sign shall not be erected in a manner that would confuse or obstruct the view of or interfere with exit signs required by

More information

NORFOLK SOUTHERN CORPORATION UNDERPASS GRADE SEPARATION DESIGN CRITERIA

NORFOLK SOUTHERN CORPORATION UNDERPASS GRADE SEPARATION DESIGN CRITERIA NORFOLK SOUTHERN CORPORATION UNDERPASS GRADE SEPARATION DESIGN CRITERIA PURPOSE AND SCOPE These criteria modify and supplement the applicable sections of the AREMA Manual of Recommended Practice in connection

More information

Vegetation Management Plan

Vegetation Management Plan Vegetation Management Plan TABLE OF CONTENTS SECTION TITLE PAGE NUMBER 1. INTRODUCTION 2 2. SAFETY 3 3. RELIABILITY 3 4. VEGETATION MANAGEMENT GUIDELINES 4 5. NEW RIGHT OF WAY GUIDELINES 6 6. VEGETATION

More information

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO SECTION 01010 - SCOPE OF WORK PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General provisions of Contract, General Conditions and Technical Specification Sections, apply to this Section. 1.02 PROJECT DESCRIPTION

More information

Pole Attachment and Conduit Usage Guidelines

Pole Attachment and Conduit Usage Guidelines Pole Attachment and Conduit Usage Guidelines Procedures, Guidelines and Requirements Covering the Installation of Communication Cables, Wireless Equipment, Banners and Seasonal Equipment on NES Poles and

More information

Electrical Inspection Site Electrical

Electrical Inspection Site Electrical 0161 Supply & Distribution Conduit, feeders, transformers, etc. Description of the building system: The building is provided with one electrical power service, rated at 208Y/120 volts, three phase, which

More information

UNDERGROUND SERVICES (RESIDENTIAL) SINGLE FAMILY RESIDENTIAL, DUPLEXES, OR TOWNHOUSES

UNDERGROUND SERVICES (RESIDENTIAL) SINGLE FAMILY RESIDENTIAL, DUPLEXES, OR TOWNHOUSES 7.01 GENERAL UNDERGROUND SERVICES (RESIDENTIAL) SINGLE FAMILY RESIDENTIAL, DUPLEXES, OR TOWNHOUSES Also refer to Chapter 3 (Service Entrances), and Chapter 4 (Metering Installation). OPPD will install,

More information

Specifications for Electrical Underground Distribution Systems from Overhead Transformation, Apartments & Condominiums

Specifications for Electrical Underground Distribution Systems from Overhead Transformation, Apartments & Condominiums Specifications for Electrical Underground Distribution Systems from Overhead Transformation, Apartments & Condominiums Specification DDS-3 OH Revision 10, March 2010 ONCOR ELECTRIC DELIVERY COMPANY SPECIFICATIONS

More information

10.0 Storm Sewer Systems

10.0 Storm Sewer Systems October 2003 Chapter 10.0, Storm Sewer Systems Page 1 10.0 Storm Sewer Systems 10.1 Introduction A storm sewer system consists of a system of inlets, pipes, manholes, junctions, cleanouts, outlets, and

More information

Load Transfer Sequencing for Maintenance of Lift Span Bridges

Load Transfer Sequencing for Maintenance of Lift Span Bridges Daniel Fryirs Structural Engineer, BG&E Pty Ltd Sam Millie Bridge Works Manager RMS South West Region James de Burgh Senior Structural Engineer, BG&E Pty Ltd Load Transfer Sequencing for Maintenance of

More information