Certification of compliance with BS EN ISO 9001: 2015 underlines our commitment to quality and service. ISO 9001

Size: px
Start display at page:

Download "Certification of compliance with BS EN ISO 9001: 2015 underlines our commitment to quality and service. ISO 9001"

Transcription

1 Roof Outlets

2 A privately owned UK company with more than fifty years experience in the industry, Wade is established as a leading manufacturer of quality drainage products. Much of the success of the business is attribu to an on-going commitment to put technology to practical use, to generate fresh ideas, and to guarantee quality assured production. This Technical Handbook presents illustrations and data from a comprehensive range of products which provide choices to enable specifier and users to select roof s that will meet their requirements. Certification of compliance with BS EN ISO 91: 215 underlines our commitment to quality and service. ISO 91

3 Contents Accessories 28 Balcony s 26 Blue roof drainage 29 Brown roof drainage 27 Car park s Considerations when selecting roof s 4 Cold roof Typical installations 9 Medium sump roof s 1 Deep sump roof s 11 Couplings 29 Downspout nozzles 25 Floor gullies 22 Flow rates 3 33 Glossary 35 Green roof drainage 27 Index of Codes 35 Installation guidelines 34 Insulated roof s 29 Inverted roof Typical installations 17 Medium sump roof s Deep sump roof s 2 Linear drainage 21 Materials and Maintenance 5 No fines screed roof 'Inverted Roof' Outfall s 29 Overflow s 29 Parapet s Planting area drainage 27 Roof garden drainage 27 Single ply membrane roof s 26 Threaded pipework adaptors 28 Warm roof Typical installations 12 Medium sump roof s Deep sump roof s

4 CONSIDERATIONS WHEN SELECTING ROOF OUTLETS The purpose of roof s is to provide effective drainage of rainwater. Selection of roof s is usually the responsibility of the specifying engineer conversant with the roof construction, roofing finish, drainage system and designated function such as a garden or parking. Some of the factors that should be considered when selecting roof s are given below. Building regulations/standards Design of flat roof drainage should be in accordance with BS EN , or other national/local regulations. Roof construction Roof s are not multi-purpose, versions are designed for use with specific types of roof construction. The depth of the structural slab, thickness and position of insulation, and the type and position of waterproofing membrane are factors to be considered. Flow rate BS EN uses localised rainfall data in l/s per m 2 and takes into account the usage and design life of the building. The quantity and types of roof to be used in a given application must be related to the roof area and expected volume of rainwater to be drained. Flow rate is the amount of water (litres/sec) a roof will drain at a given head; it is influenced by several factors: grating free area, sump capacity, design of the roof, size, and accessories such as gravel guards and filter baskets. Flow rates of Wade roof s have been established by full scale tests, at various heads of water. Results are shown on Page 31 to 33. Our online Roof catalogue includes a Flow rates and roof calculator enter the Code for a selected roof, and project data, to arrive at the quantity of roof s required. Thermal insulation To prevent condensation in roofs of heated buildings where the relative humidity may be expected to rise above 4%, it may be necessary to install additional insulation around roof bodies. Appearance Whilst of pleasing appearance, gratings are designed to be relatively inconspicuous when installed. For areas where a better class of finish is required, some products are available in nickel bronze made to order. Accessories and variations Standard optional items are readily available, such as filter baskets to intercept debris, gravel guards, bearing pans to spread the load over a large area, and underdeck clamps to secure bodies. Custom made products can be manufactured for non-standard applications. Materials and finishes Strength, corrosion resistance and appearance are important considerations when selecting roof s. Load rating It is essential that roof s withstand expected loads. This Technical Handbook shows the load rating class for each grating or roof assembly, based on BS EN 1253, as follows: H1.5 Unused flat roofs such as felt-and-gravel roofs, gravel fill roofs and similar. K3 Areas without vehicular traffic, such as balconies, terraces and roof gardens. L15 Areas with light vehicular traffic. M125 Areas with vehicular traffic, such as car parks, factories and workshops not including light commercial vehicles or heavy wheel loads. Pipework The type and size of pipework in a given installation is fundamental to the selection of roof s. Wade roof s are not trapped and can be connected to all pipework in general use; certain bodies are for direct connection to pipework, others require the use of threaded pipework adaptors or proprietary couplings. 4

5 MATERIALS AND MAINTENANCE Materials and finish of Wade roof s, described below, are selected to provide lasting performance and to blend with surroundings. The products require the minimum of maintenance, but periodic inspection should be carried out to ensure that roof s are free from gravel, leaves and other debris which could impair the performance of the system. Cast iron parts should be repainted every five years. For complete list of materials, please refer to our website. ABS Used for threaded pipework adaptors Cast aluminium BS EN 176 Used for parapet gratings An alloy chosen for its chemical resistance and durability. Cast iron BS EN 1561 Used for bodies, membrane clamping collars,extensions and threaded pipework adaptors A widely used metal in the drainage industry, its resistance to corrosion permits extended use under extreme conditions. Castings are coated with a high grade lacquer paint, applied by full immersion dip, to provide internal and external surface coverage. Paint will gradually wear off and is replaceable; oxidisation (surface rusting) is a natural process which does not weaken the material. Ductile iron BS EN 1563 and BS EN 1564 Used only for gratings A casting with the ductility of steel, yet with more than twice the tensile strength of. A zinc anti-corrosion coating is applied by sherardizing. Galvanised mild steel Used for adjus bearing pans and raising tubes A cost effective, corrosion resistant material. Gunmetal BS EN 1982 Used for downspout nozzles A cast alloy of a rich, bronze colour. Nickel bronze BS EN 1982 Satin finish Used for gratings A cast alloy which will maintain its lustre when subjected to the abrasive polishing action of traffic. The satin finish produces a fine grain effect which blends well with walls and floors. Note: Avoid covering nickel bronze items with plastic sheeting after installation, as blackening may occur. Polycarbonate Used for domes (supplied as standard) A polycarbonate/abs blend which offers durability, high impact strength and long term resistance to ultraviolet light. PVC Used for body versions for use with PVC single ply membranes This material enables a waterproof joint to be produced on site. Stainless steel austenitic grade 34 Used for gratings, domes, gravel guards, filter baskets and all fastenings A corrosion-resistant metal containing significant amounts of nickel and chromium; AISI grade 34 stainless steel is used as standard, which is sui for general use in and around buildings including most coastal locations. In applications such as swimming pools or having an aggressive atmosphere, grade 316 is recommended and is available on request. An even higher grade may be required for applications in highly corrosive environments including where exposure to seawater may be anticipated. Clean with soap and warm water rinse and wipe dry. Gratings may also be cleaned in certain dishwashers. Under no circumstances treat with metal scouring pads, metal scrapers or wire wool as these will contaminate surfaces leaving rust spots. 5

6 Wade designs and manufactures roof s for use with specific types of roof construction, worldwide. Various Wade roof s are installed in the terminal buildings at Manchester Airport WB2 Series roof for use in a cold roof Variation of a WD Series roof in an inverted roof 6

7 Flat gratings of ductile iron, with sherardized protective coating, are available in different styles and sizes. For use in show areas, certain gratings can be manufactured of nickel bronze WD34 WB324 WB616 WB516 7

8 WF Series parapet s are available with choice of grating, aluminium, stainless steel and nickel bronze; a version is available for use with PVC single ply membranes Balcony s are available with full grating or with cut-out version to accept a downpipe WB Series are installed in the Inma Building, Beirut This Technical Handbook includes ranges of standard products which are generally available ex stock. Custom-made products and accessories can be designed to suit particular applications. To enable our Technical Services Department to advise on product selection please provide the following: section drawing through the roof build up size, material and direction of pipework being connected to any other relevant design considerations. to: tech@wadeint.co.uk or call us on

9 ROOF OUTLETS FOR COLD ROOF WB414 and WB224 A cold roof is constructed such that the waterproofing membrane is at finished level and insulation (if any) is placed below the roof deck. Connections Bodies with spigot are for direct connection to BS 416 pipework, or to other sizes/materials by means of proprietary coupling; versions with threaded are for connection to pipework by means of a threaded pipework adaptor, a range of which is shown on page 28. Typical installations medium sump WB2 Series WB3 Series Secured dome clamping collar Secured flat grating clamping collar Roof deck Roof deck Body Haunching Body Pipework adaptor (select separately) Underdeck clamp (optional) Typical installations deep sump WB5 Series Features All bodies have a generous flange, essential for bonding asphalt or other membrane. All fixings are of stainless steel. Secured flat grating Body Pipework adaptor (select separately) clamping collar Roof deck Underdeck clamp (optional) Load rating The load rating class is shown for each roof ; explanation of classes is given on page 4. Flow rate explanation on page 4 and data on pages Accessories A range of accessories is shown on page 28. 9

10 ROOF OUTLETS FOR COLD ROOF MEDIUM SUMP clamping collar, Secured dome, polycarbonate Vertical threaded dia. Body, Load rating class: K dia. For optional stainless steel dome, add suffix SS to Code. Code Outlet size Weight kg WB222 2" BSP 6.2 WB223 3" BSP 5.2 WB224 4" BSP 4.6 Spigot dia. Horizontal threaded dia 'C' 'B' dia dia. Code Outlet size A B dia. Weight kg WB WB WB 'B' 35 dia. Code Outlet size A B C Weight kg WB232 2" BSP WB233 3" BSP WB234 4" BSP clamping collar, Body, Load rating class: L15 Secured grating, sherardized ductile iron Vertical threaded dia dia. Code Outlet size Weight kg WB322 2" BSP 7.5 WB323 3" BSP 6.5 WB324 4" BSP 5.9 Spigot dia. Horizontal threaded dia. 'C' Outlet spigot conforms to BS 416 'B'dia dia. 98 'B' 35 dia. Code Outlet size A B dia. Weight kg WB WB WB Code Outlet size A B C Weight kg WB332 2" BSP WB333 3" BSP WB334 4" BSP

11 ROOF OUTLETS FOR COLD ROOF DEEP SUMP Vertical threaded 45 dia. 31 dia. Slotted membrane clamping collar, sherardized Secured dome. polycarbonate 11 Body, Load rating class: K3 For optional stainless steel dome, add suffix SS to Code. dia dia. Code Outlet size A Weight kg WB414 4" BSP WB416 6" BSP WB418 2mm* clamping collar, Secured grating, sherardized ductile iron dia. 32 x Body, Load rating class: M125 dia dia. Code Outlet size A Weight kg WB514 4" BSP WB516 6" BSP WB518 2mm* Slotted membrane clamping collar, sherardized Body, Secured grating, sherardized ductile iron dia. 31 dia. 46 Load rating class: L15 dia dia. * Note: 2mm is available only as spigot. Code Outlet size A Weight kg WB614 4" BSP WB616 6" BSP WB618 2mm*

12 ROOF OUTLETS FOR WARM ROOF WC44 A warm roof is constructed such that the waterproofing membrane is above insulation which is laid on the roof deck. Connections Bodies with spigot are for direct connection to BS 416 pipework, or to other sizes/materials by means of proprietary coupling; versions with threaded are for connection to pipework by means of a threaded pipework adaptor, a range of which is shown on page 28. Typical installations Load-bearing applications Non load-bearing applications clamping collar Extension flange Bearing pan (optional) clamping collar Adjus bearing pan Insulation Insulation Roof deck Roof deck Bonded insulation jacket Underdeck clamp (optional) Bonded insulation jacket Raising tube Body Note: Details of bonded insulation jackets is shown on page 29. On site the raising tube can be easily slide-positioned through the bearing pan to suit the insulation thickness. When the required height is achieved, the tube is secured to the bearing pan using the self-tapping screws provided. The bearing pan is designed to be fixed to the deck/slab, so an underdeck clamp is not necessary. Features All bodies have a generous flange, essential for bonding asphalt or other membrane. All fixings are of stainless steel. Load rating The load rating class is shown for each roof ; explanation of classes is shown on page 4. Flow rate explanation on page 4 and data on pages Accessories A range of accessories is shown on page

13 ROOF OUTLETS FOR WARM ROOF MEDIUM SUMP * The items listed below are for use with insulation thicknesses between 8 and 1mm. Greater thicknesses can be accommodated by use of a longer connecting spigot. To specify, state the Code and insulation thickness. clamping collar, Connecting spigot, Body, Load rating class: K3 For optional stainless steel dome, add suffix SS to Code. Secured dome, polycarbonate Extension flange, Extension clamp, with neoprene gasket Vertical threaded * dia dia. Code Outlet size Weight kg WC222 2" BSP 1.9 WC223 3" BSP 9.9 WC224 4" BSP 9.3 Spigot dia. Horizontal threaded dia. 8-1* 7 8-1* 'C' 'B'dia dia. Code Outlet size A B dia. Weight kg WC WC WC 'B' 35 dia. Code Outlet size A B C Weight kg WC232 2" BSP WC233 3" BSP WC234 4" BSP clamping collar, Connecting spigot, Body, Load rating class: L15 Secured grating, sherardized ductile iron Extension flange, Extension clamp,, with neoprene gasket Vertical threaded 8-1* dia dia. Code Outlet size Weight kg WC322 2" BSP 12.2 WC323 3" BSP 11.2 WC324 4" BSP 1.6 Spigot 8-1* dia. Horizontal threaded 8-1* dia. 'C' Outlet spigot conforms to BS 416 'B'dia dia. Code Outlet size A B dia. Weight kg WC WC WC 'B' 35 dia. Code Outlet size A B C Weight kg WC332 2" BSP WC333 3" BSP WC334 4" BSP

14 ROOF OUTLETS FOR WARM ROOF MEDIUM SUMP * The items listed below are for use with insulation thicknesses between 2 and 135mm. Greater thicknesses can be accommodated by use of a longer raising tube. To specify, state the Code and insulation thickness. clamping collar, Secured dome, polycarbonate Raising tube, galvanised mild steel Adjus bearing pan, galvanised mild steel Body, Load rating class: H1.5 For optional stainless steel dome, add suffix SS to Code. Vertical threaded dia. 22 dia. Spigot dia. 22 dia dia. 5 x 5 2 min. 135 max.* 135 'B' dia. 24 dia. 5 x 5 2 min. 135 max.* Code Outlet size Weight kg WC422 2" BSP 9.7 WC423 3" BSP 8.7 WC424 4" BSP 8.1 Code Outlet size A B dia. Weight kg WC WC WC clamping collar, Secured grating, sherardized ductile iron Body, Raising tube, galvanised mild steel Load rating class: H1.5 Adjus bearing pan, galvanised mild steel Vertical threaded dia. 22 dia. 24 dia. 5 x 5 2 min. 135 max.* Spigot dia. 22 dia. 'B' dia. 24 dia. 5 x 5 2 min. 135 max.* Code Outlet size Weight kg WC522 2" BSP 11. WC523 3" BSP 1.1 WC524 4" BSP 9.1 Code Outlet size A B dia. Weight kg WC WC WC

15 ROOF OUTLETS FOR WARM ROOF DEEP SUMP The items listed below are for use with insulation thicknesses between 8 and 115mm. Vertical threaded 45 dia. 31 dia. clamping collar, sherardized Secured dome, polycarbonate 11 Extension clamp,, with neoprene gasket Extension flange, Body, Load rating class: K3 For optional stainless steel dome, add suffix SS to Code. 186 dia dia. Code Outlet size Weight kg WC644 4" BSP 24.1 WC646 6" BSP 21.6 clamping collar, Secured grating, sherardized ductile iron dia. 32 sq Extension clamp,, with neoprene gasket Body, Extension flange, dia dia. Load rating class: M125 Code Outlet size Weight kg WC744 4" BSP 34.5 WC746 6" BSP 32. clamping collar, sherardized. Secured grating, sherardized ductile iron 45 dia. 31 dia. Extension clamp,, with neoprene gasket Extension flange, Body, Load rating class: L dia dia. Code Outlet size Weight kg WC144 4" BSP 25.4 WC146 6" BSP

16 ROOF OUTLETS FOR WARM ROOF DEEP SUMP * The items listed below are for use with insulation thicknesses between 2 and 135mm. Greater thicknesses can be accommodated by use of a longer raising tube. To specify, state the Code and insulation thickness. Vertical threaded clamping collar, sherardized Secured dome, polycarbonate dia. 31 dia. Body, Adjus bearing pan, galvanised mild steel min. 135 max.* dia. 356 dia. 6 x 6 Raising tube, galvanised mild steel For optional stainless steel dome, add suffix SS to Code. Load rating class: H1.5 Code Outlet size A Weight kg WC814 4" BSP WC816 6" BSP WC818 2mm clamping collar, Secured grating, sherardized ductile iron dia. 32 x 32 Body, min. 135 max.* Adjus bearing pan dia. 356 dia. 6 x 6 Raising tube, galvanised mild steel Load rating class: H1.5 Code Outlet size A Weight kg WC914 4" BSP WC916 6" BSP WC918 2mm clamping collar, sherardized Secured grating, sherardized ductile iron 45 dia. 31 dia. Body, Adjus bearing pan, galvanised mild steel min. 135 max.* Table dia. 356 dia. 6 x 6 Raising tube, galvanised mild steel Load rating class: H1.5 Code Outlet size A Weight kg WC1114 4" BSP WC1116 6" BSP WC1118 2mm Note: 2mm is available only as spigot. 16

17 ROOF OUTLETS FOR INVERTED ROOF WD34 Typical installations WB 2 series An inverted roof is constructed such that the waterproofing membrane is above the roof deck and beneath the insulation. Generally, rainwater flows between any paving slabs, through any porous ballast and insulation, onto and along the membrane, to drain away through a roof. Connections Bodies with spigot are for direct connection to BS 416 pipework, or to other sizes/materials by means of proprietary coupling; versions with threaded are for connection to pipework by means of a threaded pipework adaptor, a range of which is shown on page 28. WD 2, 3 and 7 series clamping collar Gravel guard Flat grating Slotted membrane clamping collar Roof finish Insulation Screed Roof finish Insulation Roof deck Roof deck Body Underdeck clamp (Optional) Body Pipework adaptor (Select separately) clamping collar Paving Gravel guard Spacer Spacer Flat grating Paving Slotted membrane clamping collar Insulation Insulation Screed Roof deck Roof deck Body Underdeck clamp (Optional) Body Pipework adaptor (Select separately) WD 5 and 6 series Flat grating Body Slotted membrane clamping collar Roof finish Insulation Roof deck Pipework adaptor (Select separately) Features All bodies have a generous flange, essential for bonding asphalt or other membrane. All fixings are of stainless steel. Load rating The load rating class is shown for each roof ; explanation of classes is given on page 4. Flow rate explanation on page 4 and data on pages Slotted collar In some versions this is used as a raising piece and as a membrane clamping collar, in others it fits into a separate membrane clamp and is, therefore, used only as a raising piece. May be wrapped with a geotextile membrane to prevent ingress. Accessories A range of accessories is shown on page

18 ROOF OUTLETS FOR INVERTED ROOF MEDIUM SUMP Gravel guard, perforated stainless steel Body, Load rating class: K3 For optional stainless steel dome, add suffix SS to Code. Secured dome, polycarbonate clamping collar, Vertical threaded dia dia. Code Outlet size H Weight kg WB222G1 2" BSP WB223G1 3" BSP WB224G1 4" BSP WB222G2 2" BSP WB223G2 3" BSP WB224G2 4" BSP 'H' Note: The domed assemblies on this page include a gravel guard (height of 15 or 2). Other heights can be made to special order advise height. Spigot dia. 'H' Horizontal threaded dia. 'H' 'C' Outlet spigot conforms to BS 416 'B' dia dia. Code Outlet size A B dia. H Weight kg WB22G WB23G WB24G WB22G WB23G WB24G 'B' Code Outlet size A B C H Weight kg WB232G1 2" BSP WB233G1 3" BSP WB234G1 4" BSP WB232G2 2" BSP WB233G2 3" BSP WB234G2 4" BSP Adjus collar, Body, Load rating class: L15 Secured grating, sherardized ductile iron Slotted membrane clamping collar, * To increase height shown, use extensions WG51/WG52 ( page 28) Vertical threaded 78 min. 15 max.* dia dia. Code Outlet size Weight kg WD222 2" BSP 12.7 WD223 3" BSP 11.7 WD224 4" BSP 11.1 Spigot Outlet spigot conforms to BS min. 15 max.* dia. 'B' dia dia. Code Outlet size A B dia. Weight kg WD WD WD Horizontal threaded 78 min. 15 max.* dia. 'B' 'C' Code Outlet size A B C Weight kg WD232 2" BSP WD233 3" BSP WD234 4" BSP

19 ROOF OUTLETS FOR INVERTED ROOF MEDIUM SUMP Adjus collar, Secured grating, sherardized ductile iron Vertical threaded 94 min. 121 max.* 224 x 224 Body, Load rating class: L15 Slotted membrane clamping collar, * To increase height shown, use extensions WG51/WG52 ( page 28) dia. Code Outlet size Weight kg WD322 2" BSP 13.9 WD323 3" BSP 12.9 WD324 4" BSP 12.3 Spigot 94 min. 121 max.* 224 x 224 Horizontal threaded 94 min. 121 max.* 224 x 224 Outlet spigot conforms to BS 'B' dia dia 'B' 'C' Code Outlet size A B dia. Weight kg WD WD WD Code Outlet size A B C Weight kg WD332 2" BSP WD333 3" BSP WD334 4" BSP Spigot Adjus collar Body, Load rating class: K Secured 'Streamline' grating and frame stainless steel Slotted membrane clamping collar, * To increase height shown, use extensions WG51/WG52 ( page 28). For grade 316 grating and frame add suffix M to the Code. 2 x 2 Vertical threaded 86 min. 113 max.* x dia. Code Outlet size Weight kg WD722 2" BSP 12.7 WD723 3" BSP 12.9 WD724 4" BSP 12.3 Horizontal threaded 86 min. 113 max.* 86 min. 113 max.* x 2 'C' 'B' dia dia. Code Outlet size A B dia. Weight kg WD WD WD 'B' Code Outlet size A B C Weight kg WD732 2" BSP WD733 3" BSP WD734 4" BSP

20 ROOF OUTLETS FOR INVERTED ROOF DEEP SUMP Vertical threaded 22 dia. Adjus collar clamping collar, sherardized Body, Secured grating, sherardized ductile iron Slotted collar, 9 min. 117 max.* dia dia. 46 Load rating class: L15 * To increase height shown, use extensions WG51/WG52 ( page 28) Code Outlet size A Weight kg WD514 4" BSP WD516 6" BSP WD518 2mm Adjus collar, clamping collar, sherardized Secured grating, sherardized ductile iron Slotted collar, 16 min. 133 max.* x Body, Load rating class: L15 * To increase height shown, use extensions WG51/WG52 ( page 28) dia dia. Code Outlet size A Weight kg WD614 4" BSP WD616 6" BSP WD618 2mm Adjus collar clamping collar, sherardized Body, Load rating class: K3 Secured 'Streamline' grating and frame stainless steel Slotted collar, * To increase height shown, use extensions WG51/WG52 ( page 28). For grade 316 grating and frame add suffix M to the Code. Note: 2mm is available only as spigot. 98 min. 125 max.* x 2 dia dia. Code Outlet size A Weight kg WD644 4" BSP WD646 6" BSP WD648 2mm

21 LINEAR DRAINAGE For use in roofs and floors, Wade offers a range of stainless steel channel with a choice of gratings of stainless steel, nickel bronze and. Details are included in our Technical Handbook Linear Drainage and on our website. Stainless steel channel with Streamline stainless steel grating. Heavy duty bar grating designed for trolley wheel-loading. Austenitic stainless steel channel and grating meet the high standards of hygiene demanded in today s working environments. Channel profile SVF ensures watertight connection when used with flexible sheet floor covering such as vinyl. SS38AC Mitred Streamline grating (patent no. GB ). A selection of gratings. Technical Handbook Linear Drainage 21

22 FLOOR GULLIES AND ACCESS COVERS Wade manufactures a comprehensive range of floor gullies for use with various floor finishes including ceramic tiles, marble, terrazzo, epoxy resin and sheet floor covering such as vinyl. Gratings are available made of stainless steel, nickel bronze and polished bronze, with choices of size, style and connection type; bodies are available made of stainless steel, and gunmetal. Details are included in our Technical Handbook Floor gullies and access covers and on our website. A selection of floor gullies, access covers and accessories. A Vari-Level floor gully assembly showing optional grating extension and bolt-on funnel. Super Seal access cover in a tiled floor. Stainless steel gully with side inlets in a tiled floor. Watertight trapped drainage in a vinyl covered timber floor. Watertight drainage in a vinyl covered timber floor. Technical Handbook Floor gullies and access covers Sliding access cover on a vinyl covered floor (Patent pending). 22

23 Wade drainage products are installed in and near all kinds of buildings, some examples of which are shown below. A.E.L.T.C.C. Wimbledon. Chep Lap Kok Airport, Hong Kong. Drainage and access in a vinyl floor. A McDonalds Restaurant. The British Library. Asda Store, Runcorn. Drainage beside the Thames. 23

24 PARAPET OUTLETS 2", 3" & 4" OUTLET Wade offers a range of parapet s often used with downspout nozzles as shown on page opposite. A membrane clamping collar, of sheradized ductile iron is supplied with body versions up to 4" (of stainless steel with PVC body versions). This allows the grating to be removed, for maintenance purposes, without disturbing the membrane. WF2 to WF34 WF42 to WF44 Body clamping collar Grating Screed WF72 to WF74 WF15 to WF135 Code Connections Bodies are reversible to provide horizontal or vertical for connection to pipework by means of a threaded pipework adaptor, a range of which is shown on page 28. Flow rate explanation on page 4 and data on pages Options Gravel guard stainless steel To prevent ingress of gravel. Flow rate may be reduced. To specify/order and suffix G (cannot be used with WF72-WF74). Grade 316 (stainless steel grating versions) add suffix M. 24 Outlet size A B kg Material Grating Body WF2 2" BSP Nickel bronze Cast iron WF3 3" BSP Nickel bronze Cast iron WF4 4" BSP Nickel bronze Cast iron WF12 2" BSP Aluminium Cast iron WF13 3" BSP Aluminium Cast iron WF14 4" BSP Aluminium Cast iron WF22 2" BSP Cast iron Cast iron WF23 3" BSP Cast iron Cast iron WF24 4" BSP Cast iron Cast iron WF32 2" BSP Stainless steel Cast iron WF33 3" BSP Stainless steel Cast iron WF34 4" BSP Stainless steel Cast iron WF42 2" BSP Stainless steel 'L' Cast iron WF43 3" BSP Stainless steel 'L' Cast iron WF44 4" BSP Stainless steel 'L' Cast iron WF72 2" BSP Stainless steel Cast iron WF73 3" BSP Stainless steel Cast iron WF74 4" BSP Stainless steel Cast iron WF15 4" BSP Nickel bronze PVC* WF115 4" BSP Aluminium PVC* WF125 4" BSP Cast iron PVC* WF135 4" BSP Stainless steel PVC* * With PVC body for use with single ply membranes, see page 26 for illustration. L denotes shape of stainless steel grating. WF2 WF34 'B' WF42 WF44, WF72 WF74 'B' WF15 WF " BSP

25 PARAPET OUTLETS 6" OUTLET Wade offers a range of parapet s often used with downspout nozzles as shown below. A membrane clamping collar, of stainless steel is supplied with stainless steel grating versions. This allows the grating to be removed, for maintenance purposes, without disturbing the membrane. Versions with aluminum grating use the grating as a membrane clamp. WF46 WF76 WF46, WF WF156 WF166 WF " BSP 64 WF156, WF166, WF Code Connections Bodies are reversible to provide horizontal or vertical for connection to pipework by means of a threaded pipework adaptor, a range of which is shown on page 28. Flow rate Outlet size A B kg Material Grating Body WF46 6" BSP Stainless steel 'L' Cast iron WF76 6" BSP Stainless steel Cast iron WF156 6" BSP Aluminium Cast iron WF166 6" BSP Aluminium Cast iron WF176 6" BSP Aluminium Cast iron L denotes shape of stainless steel grating. explanation on page 4 and data on pages " BSP Options Gravel guard stainless steel To prevent ingress of gravel. Flow rate may be reduced. To specify/order and suffix G. Grade 316 (stainless steel grating versions) add suffix M DOWNSPOUT NOZZLES CAST GUNMETAL Wade offers a range of downspout s with threaded inlet, designed for installation on the outside face of a parapet wall to discharge water to lower levels. Typical installation The illustration shows a downspout nozzle connected to a parapet. Connecting spigots are shown on page 29. To calculate required length in cm, use formula L = (T A), and round up to the nearest cm. 18 dia dia. Downspout nozzle T (cm) Gravel guard (optional) Grating clamping collar Code Outlet size A Weight kg WJ12 2" BSP WJ13 3" BSP WJ14 4" BSP dia dia Connecting spigot Body Code Outlet size A Weight kg WJ22 2" BSP WJ23 3" BSP

26 BALCONY OUTLETS CAST IRON For use on balconies with an asphalt finish, Wade offers balcony s with option of a full grating or with cut-out for a downpipe. 192 x Flow rate explanation on page 4 and data on pages Typical installation The illustration shows a balcony installed with an asphalt finish. The grating is designed to allow a rainwater downpipe from the balcony above to be fitted into the body eliminating spillage onto the walkway. Outlet spigot conforms to BS416 / DIN19522 Code Outlet size Weight kg 111 WF64 1mm 6.2 Load rating class: K3 Rainwater downpipe Grating Cut out accepts downpipe of 116mm dia. max. 192 x Body Outlet spigot conforms to BS416 / DIN19522 Code Outlet size Weight kg WF74 1mm 5.7 Load rating class: K3 111 ROOF OUTLETS FOR USE WITH PVC SINGLE PLY MEMBRANES WC224Z roof with WG12 underdeck clamp and WT13 threaded pipework adaptor, in a warm roof with single ply membrane. Warm and cold roofs By application of a rigid PVC flange at our works, all versions of roof s, with the range of accessories, may be used with PVC single ply membranes. PVC based membranes may be solvent or heat welded directly to the PVC flange on site to produce a watertight seal. To specify/order add suffix Z to the Code. WF15 parapet with connecting spigot and WJ14 downspout nozzle. Parapet s Wade offers a range of parapet s with reversible, PVC body, to provide horizontal or vertical threaded, with grating options. For dimensions and drawings see page 24. Parapet s can be used with downspout nozzles as illustrated on page

27 BROWN ROOF DRAINAGE FOR PLANTING AREAS AND ROOF GARDENS Wade offers a range of products providing drainage of moisture in planting areas and flower boxes, without loss of soil. P81 For applications where a grating is required at the surface, in a paved area, or where access is required; for use with D1-D12 series bodies, shown on page 5B ntcibm of our Floor Gullies and Access Covers Technical Handbook and on our website. Code Weight (min.) kg P81 + length (mm) 4. Load rating class: K3 Gravel Ballast guard length is manufactured to specific requirements: 1mm min. 22 dia. Grating Frame Perforated ballast guard (3 dia. holes) Clamp collar Material Grating ductile iron, sherardized Ballast guard stainless steel Frame/clamp collar, lacquered P91 For applications where the standpipe is concealed by soil; for use with Vari-Level bodies shown in Section 5B of our Floor Gullies and Access Covers Technical Handbook and on our website. Dome is removable for access purposes dia. Removable dome Soil Damp proof membrane Standpipe length is manufactured to specific requirements: 2mm min. 12 dia. Vari-Level body Code Weight (min.) kg P91 + Standpipe length (mm).7 P1 series For applications where all drainage is concealed by soil; versions available to suit asphalt or sheet/brush on membranes. Material Dome copper Standpipe PVC 4" NPSM thread Type 1 Soil Damp proof membrane Type 2 Soil Asphalt membrane dia. Perforated stainless steel dome (3 dia. holes) 138 dia. Slab C2-C5 series body Body shown on pages 5Bntci1/5Bntci2 of our Floor Gullies and Access Covers Technical Handbook and on our website. Slab D1-D12 series body Body shown on pages 5Bntcibm of our Floor Gullies and Access Covers Technical Handbook and on our website. Material: Stainless steel May be wrapped with a geotextile membrane to prevent ingress. Code Installation type Dome free area cm 2 P11 1 Sheet or brush on P12 2 All types (inc. asphalt) kg 27

28 ACCESSORIES Gravel guard Stainless steel For use with domes on all roofs having a deep gravel finish; designed to retain insulation and/or to prevent the ingress of gravel, both in service and when the dome is removed for cleaning. Versions of different height may be made to special order advise required height. Flow rate may be reduced. Underdeck clamp - Stainless steel To secure a body to a roof deck (Cannot be used with horizontal ). For medium sump s Code A B Weight kg WG 'B' 25 For medium sump s Code Height Dia. Weight kg WG WG For deep sump s Code Height Dia. Weight kg WH WH For deep sump s Code A B Weight kg WH Bearing pan Galvanised mild steel To spread the load over a larger area. (Cannot be used with horizontal ) 8.5 Filter basket Stainless steel grade 34 Used to intercept debris. Note: Filter baskets may require regular maintenance and will reduce flow rate by varying extent depending on body selected. Extension Cast iron Used to raise the height of a grating above a body. (Inverted roof only). May be stacked to achieve extra height. For medium sump s For deep sump s For medium sump s For deep sump s For WD2-WD7 series Code Height Weight kg WG21 5 sq. 2.3 Code Height Weight kg WH31 61 sq. 2.9 Code Weight kg WG31.2 Code Compatible with Weight kg WH42 WC7, WC9, WB5.6 Code Height Weight kg WG WG Threaded pipework adaptors A comprehensive range of adaptors, shown in the following, is available to enable bodies with BSP threaded to be connected speedily and effectively to all pipework in general use. To complete the connection a coupling may be required as indicated. Longer adaptors, such as required to pass through a slab, can be made in 1mm increments up to 9mm (except T172 and T174). To specify/order and and length (mm) to Code. On request, adaptors may also be threaded both ends. For details, please contact our Technical Services Department. Body BSP 28 Pipework system Nom. dia. mm Code O.D. mm Threaded pipework adaptor Length mm Material Weight kg Required coupling 2" Cast iron BS T Mild steel, sherardized.5 Proprietary 2" Cast iron BS WT Mild steel, sherardized 1. Proprietary 3" Cast iron BS T Mild steel, sherardized.9 Proprietary 3" Cast iron BS WT Mild steel, sherardized 1.7 Proprietary 4" Cast iron BS T Cast iron 1.2 Proprietary 4" Cast iron BS WT Cast iron 2.5 Proprietary 6" Cast iron BS T Cast iron 1.2 Proprietary 6" Cast iron BS WT Cast iron 4. Proprietary 4" Cast iron BS WT Cast iron 2.6 Proprietary 6" Cast iron BS WT Cast iron 4.1 Proprietary 2" Cast iron BS EN 877 (Ensign+SMU) 5 WT Mild steel, sherardized 1. Proprietary 3" Cast iron BS EN 877 (SMU) 75 WT Mild steel, sherardized 1.2 Proprietary 3" Cast iron BS EN 877 (Ensign) 75 WT Mild steel, sherardized 1.7 Wade T163 4" Cast iron BS EN 877 (Ensign+SMU) 1 WT Cast iron 2.5 Proprietary 6" Cast iron BS EN 877 (Ensign+SMU) 15 WT Cast iron 4. Proprietary 2" Stainless steel BS EN T Plastic (ABS).2 Proprietary 4" Stainless steel BS EN T Plastic (upvc).4 Proprietary 6" Stainless steel BS EN T Plastic (ABS).6 Proprietary 2" Plastic 5 T172* 54* 6 Plastic (ABS).1 None 3" Plastic 82 T Plastic (ABS).2 Proprietary 4" Plastic 11 T174* 11* 126 Plastic (ABS).2 None 6" Plastic 16 T Plastic (ABS).6 Proprietary 4" HDPE 1 T Cast iron 1.2 T151 *Solvent weld socket internal diameters shown Longer adaptors 1mm nominal diameter versions above 6mm length will be made of sheradized mild steel instead of.

29 OUTLETS FOR BLUE ROOF, MISCELLANEOUS OUTLETS AND OPTIONS Vertical overflow Polypropylene and ABS The roof dome is replaced with a corresponding overflow of a diameter to match the roof. Height of overflow pipe to be adjusted as required on site, either by cutting to length or solvent welding an additional section of pipe. Basic heights or different diameters are as below: Dome Stainless steel grade 34 Alternative to standard polycarbonate version. To specify/order add SS to Code of roof. For grade 316 add SSM to Code of roof. Height mm Dia. Overflow upstand 3 2" Socket " Spigot " Socket 1. To specify/order quote Code of selected medium sump roof plus suffix OF eg. WB24OF Horizontal overflow Nickel bronze For horizontal installation, to provide an overflow in a parapet wall. A membrane clamping collar (max. clamped membrane thickness is 6mm) enables removal of the grating for maintenance purposes without disturbing the membrane. also WJ22 downspout nozzle (page 25) and U27 connecting spigot. Frame is sheradized. Code kg Grating mm dia. Outlets kg N " BSP female 1.2 Outfall s Stainless steel grade 34, satin finish top hinged Bonded insulation jacket A factory fitted bonded insulation jacket is used to prevent condensation forming on the underside of a body. To specify/order add suffix K Code of roof. Couplings To connect roof s to pipework made by others. T151 MJ coupling BS 416 to plastic From Connections Connecting spigot Threaded each end to enable connection between products with BSP threaded inlet/ (e.g. parapet and downspout nozzle on pages 24-25). To specify/order quote required Code from below, changing last two digits (xx) to denote required length in cm (max. length 99mm). To T163 MJ coupling 75mm BS 416 to Ensign Coupling Code 1mm BS mm plastic T mm BS mm DIN Ensign T kg Typical installation Code Size Max pipework dia. kg WJ sq WJ sq WJ sq Code Size Material U27xx* 2" BSP Plastic (ABS) U37xx 3" BSP Plastic (ABS) U47xx 4" BSP Plastic (upvc) * Note: Alternative product, use 2 x T172 with standard 5mm plastic pipe cut to length on site. 29

30 FLOW RATES Flow rate testing a WB224 roof Flow rates of Wade roof s have been established by full-scale tests. The values shown in graphs on pages are 75% of such tests. The graphs show, for given heads of water, flow rate (l/s) and area drained (m 2 ) at a rainfall rate of 75mm/h** or.21 l/s per m 2.* * Rainfall rate BS EN l/s per m 2 equates to 75mm/h, as previously recommended in BS6367 (superseded by BS EN :2). BS EN uses rainfall charts which provide more localised data given in l/s per m 2. To calculate the area drained [A] for a specific rainfall rate [R] (l/s per m 2 ) use the following formula. A (m 2 ) =.21 x a (m l/s per m 2 ) R (l/s per m 2 ) (a: area drained, obtained from appropriate graph). ** Rainfall rate BS mm/h has been used as previously recommended in BS 6367 (withdrawn September 2). Area drained [A] at a different rainfall rate [R] can be calculated by using the following formula. A (m 2 ) = 75 x a (m 75mm/h) R (mm/h) (a: area drained, obtained from appropriate graph). For assistance please contact our Technical Services Department. Our website electronic catalogue includes area/rainfall calculators based on the above formulas. Note: Flow rates shown in graphs will be reduced if accessories such as filter baskets or gravel guards are used. Please contact our Technical Services Department for further information. 3

31 FLOW RATES Parapet s Head (mm) " s: Horizontal Flow rate (l/s) 1 A ", 3" and 4" OUTLETS 2" s: Vertical WF2 to WF34 WF42 to WF46 Head (mm) Flow rate (l/s) 1 A Roof area drained (m 2 ) at 75mm/h or.21 l/s per m 2 rainfall 3" s: Horizontal Flow rate (l/s) 1 A WF72 to WF76 WF15 to WF Roof area drained (m 2 ) at 75mm/h or.21 l/s per m 2 rainfall 3" s: Vertical Flow rate (l/s) 1 2 A Head (mm) 3 2 Head (mm) Roof area drained (m 2 ) at 75mm/h or.21 l/s per m 2 rainfall A Roof area drained (m 2 ) at 75mm/h or.21 l/s per m 2 rainfall Head (mm) " s: Horizontal Flow rate (l/s) 1 A " OUTLETS WF156 WF166 Head (mm) " s: Vertical Flow rate (l/s) A Head (mm) Roof area drained (m 2 ) at 75mm/h or.21 l/s per m 2 rainfall 6" s: Horizontal B Head (mm) Roof area drained (m 2 ) at 75mm/h or.21 l/s per m 2 rainfall 6" s: Vertical Flow rate (l/s) Flow rate (l/s) 1 2B D C B C D WF176 C Roof area drained (m 2 ) at 75mm/h or.21 l/s per m 2 rainfall D Roof area drained (m 2 ) at 75mm/h or.21 l/s per m 2 rainfall Balcony s 1mm s: Vertical Flow rate (l/s) 1 2 B A 6 5 WF6 series WF7 series 4 3 Head (mm) Roof area drained (m 2 ) at 75mm/h or.21 l/s per m 2 rainfall A B 31

32 FLOW RATES 5 (Medium sump) 2"/ 5mm Flow rate (l/s) A CD B 12 A WB2/22 WC2/22/4/42 4 Head (mm) Roof area drained (m 2 ) at 75mm/h or.21 l/s per m 2 rainfall B WB3/32 WC3/32/5/52 WD2/22/3/32/7/72 (Medium sump) 3"/ 75mm 5 Flow rate (l/s) B A 5 D C Head (mm) C WB23 WC Roof area drained (m 2 ) at 75mm/h or.21 l/s per m 2 rainfall D WB33 WC33 (Medium sump) 4"/ 1mm 5 Flow rate (l/s) DB C A 12 4 Head (mm) Roof area drained (m 2 ) at 75mm/h or.21 l/s per m 2 rainfall

33 FLOW RATES 5 (Deep sump) 4"/ 1mm Flow rate (l/s) D A B C 12 A WB6 WC1/11 4 Head (mm) Roof area drained (m 2 ) at 75mm/h or.21 l/s per m 2 rainfall B WB4 WC6/8 (Deep sump) 6"/ 15mm 5 4 Flow rate (l/s) D A 12 C B C WB5 WC7/9 Head (mm) Roof area drained (m 2 ) at 75mm/h or.21 l/s per m 2 rainfall D WD5 WD6 WD74 33

34 INSTALLATION GUIDELINES General The design of the layout of roof s should be in accordance with the recommendations given in BS EN 1256:3. Wade roof s should be placed at the roof low points to allow efficient flow of water to the s. Illustrations of typical installations are given in each section of this handbook. Installation instructions are supplied with goods and are available on our website. 1. Check dimensions 2. Fit adaptor, check 3. Install body Prior to installation, check height of components to ensure compatibility with roof build-up, making allowances for the membrane thickness. Where applicable, screw threaded pipework adaptor into body, using a sui sealant to ensure the joint is watertight. Position body in roof deck and ensure is accessible for pipework connection. Install body such that flange is flush or sub-flush with roof deck. Ensure body is fixed securely, either bonded or clamped to the deck if not cast-in. Note: flange level is determined by roof build-up. 4. Dress membrane and clamp 5. Install insulation 6. Fit grating, apply finish Refer to membrane manufacturer s instructions. Prepare flange of body with sui primer and apply membrane, dressing over flange and into sump of body. Position membrane clamping collar and secure to body using fixings supplied. Install any intermediate roof build-up (e.g. insulation) around s. Fit dome/grating using height adjustment where applicable to ensure grating is flush with roof finish. Apply roof finish around grating. 34

35 GLOSSARY AND INDEX Adjus bearing pan Component used with a raising tube on ROOF OUTLETS for WARM ROOF which enables the installer to set the distance between the FLANGE and roof deck at any point between 2 and 135mm. Balcony Design of ROOF OUTLET with a flat GRATING; a version allows a downpipe from the level above, as well as surface water, to pass through. Bearing pan Profiled plate into which a BODY can be located to spread the weight of the body over a larger area of roof. Blue roof Roof design intended to store water. Body Bowl-like part of a ROOF OUTLET, set in the roof, to which the DOME or GRATING is fixed and the pipework connected. Brown roof Roof finished with soil/gravel/rubble. Clamp MEMBRANE CLAMPING COLLAR OR UNDERDECK CLAMP. Cold roof Construction method where the waterproofing MEMBRANE is at finished level and insulation (if any) is placed below the roof deck. Dome Removable, raised GRATING used on ROOF OUTLETS. The vertical slot design resists blockage by debris, leaves etc. Domical grating DOME. Downspout nozzle Decorative spout used to discharge rainwater through a wall to a lower level. Normally used with a PARAPET OUTLET. Extension flange Raises the height of a GRATING above a BODY. Filter basket Removable receptacle fitted within a ROOF OUTLET to intercept debris. Flange Part of a BODY leading to its mouth, over which the waterproofing MEMBRANE is laid. Flow rate Maximum amount of water (I/sec) that can be drained at a given HEAD OF WATER. Frame Support for a GRATING which is connected to a BODY either directly or by means of a MEMBRANE CLAMPING COLLAR. Gargoyle DOWNSPOUT NOZZLE. Grating Removable, exposed component of a ROOF OUTLET with apertures to receive rainwater; generally fitted in a frame. Gravel guard Mesh screen fitted to prevent gravel falling into the ROOF OUTLET when the DOME or GRATING is removed. Parapet version must be removed first to gain access to grating. Green roof Gardens, shrubberies etc. located on a roof. Gully Discharge fitting designed to be installed in a floor. (Please refer to Other Wade Literature on back page). Head of water Height of water above the GRATING, used to determine FLOW RATE. l.d. Internal diameter. Inverted roof Construction method where the waterproofing MEMBRANE is above the roof deck, and below the insulation. Load rating Capability to withstand loads, expressed in classes. ( page 4 for details). Waterproofing material (asphalt, roofing felt, EPDM sheet, PVC etc.) laid on a roof to make it watertight. clamping collar Used to clamp a MEMBRANE to a body. M.J. Mechanical joint. No-fines screed Construction method normally used for roof-top car parks; the screed is porous and allows surface water to drain over the entire area. O.D. Outside diameter. Outlet Part of a BODY through which rainwater is discharged into connecting pipework. Overflow Roof with an upstand to provide drainage when water reaches a specified depth. Parapet A design of ROOF OUTLET allowing drainage horizontally through a parapet wall; can also be used vertically. Raising piece EXTENSION FLANGE. Raising tube ADJUSTABLE BEARING PAN. Roof An assembly generally comprising a BODY and DOME or flat GRATING, which allows the efficient drainage of rainwater from a roof. Single-ply membrane PVC, waterproof, sheet material laid on a flat roof to make it watertight; requires ROOF OUTLETS with Z FLANGE. Spigot BODY with an integral spigot. Sump Part of a BODY between the FLANGE and OUTLET. Threaded BODY in which the OUTLET connection is a BSP thread into which a SPIGOT ADAPTOR can be fitted to allow connection to pipework. Threaded pipework adaptor Converts threaded BODY to a spigot allowing connection to pipework using a proprietary coupling. Two-way PARAPET OUTLET. Underdeck clamp Framework fitted to the underside of a BODY under the roof deck, to hold the body firmly in place; normally used on metal deck roofing in conjunction with a BEARING PAN; may also be fitted on a concrete slab where casting-in is not possible. Warm roof Construction method where the waterproofing MEMBRANE is above insulation which is laid on the roof deck. Z flange PVC collar which is factory fitted to the FLANGE of a BODY to enable jointing on site to a PVC SINGLE PLY MEMBRANE. Code index Code Page N P T U27-U47 29 WB2 1,18 WB3 1 WB WC2,3 13 Code Page WC4,5 14 WC6,7 15 WC8,9 16 WC1 15 WC11 16 WD2 18 WD3 19 WD5-6 2 Code Page WD7 19 WF,1 24,25 WF6,7 26 WG 28 WH 28 WJ1,2 25 WJ3 29 WT 28 35

36 About Wade Visit our website for online versions of our product catalogue, price list, conditions of sale, news, job opportunities, Wade-CAD, Wade-BIM and PDF format technical handbooks. Wade-CAD is for users who require drawings of Wade products; files are in both DXF and AutoCAD DWG format. Wade-BIM is our library of BIM 3D models available for a range of products in Revit format. Other Wade literature Service Product information and technical advice are available from the Wade Technical Services Department at Halstead, Essex, from Wade Technical Consultants located throughout the UK and from selected distributors throughout the world. A computeraided design service is available free of charge for layouts and assemblies of Wade products. Warranty The Company warrants its products to be free from defects in material and workmanship for a period of 12 months from the date of delivery. The Company s obligation under this warranty is limited, at its option, to the repair or replacement, free of charge, or refund of the net invoiced price of any part found to be defective, and which, in the Company s opinion, has not been subject to undue wear and tear, accident, alteration, abuse or misuse. Consequential damages are expressly disclaimed. Technical advice from Wade International Limited, whether verbal, in writing or by way of trials, is given in good faith but without warranty. The application, use and installation of the Company s products are beyond the control of the Company, and the purchaser is solely responsible for ensuring that goods are fit for any particular purpose. In line with the Company s policy of continual research and development, product specifications and availability are subject to change or withdrawal without prior notice. Dimensions In line with general practice all dimensions shown are nominal. Dimensions are generally given in mm (other units are specified). QUALITY BY TRADITION PERFORMANCE BY DESIGN January 218 Wade International Ltd. Third Avenue HALSTEAD Essex CO9 2SX UK Telephone: +44() Facsimile: +44() sales@wadeint.co.uk web site:

CI/SfB. April Roof Outlets

CI/SfB. April Roof Outlets Uniclass EPIC CI/SfB April 24 Roof s Aprivately owned U.K. company with more than forty years experience in the industry, Wade is established as a leading manufacturer of quality drainage products. Much

More information

CI/SfB (52) Floor gullies and access covers

CI/SfB (52) Floor gullies and access covers Uniclass EPIC CI/SfB (52) Floor gullies and access covers Contents Section 1 Introduction 2 Design considerations 3 Installation guidelines 4 Stainless steel gullies 4B Body assemblies 4G Gratings See

More information

S E L E C T I O N A N D I N S T A L L A T I O N G U I D E

S E L E C T I O N A N D I N S T A L L A T I O N G U I D E Uniclass EPIC CI/SfB (52) October 2005 Drainage Products S E L E C T I O N A N D I N S T A L L A T I O N G U I D E Aprivately owned U.K. company with more than forty years experience in the industry, Wade

More information

ROOF DRAINS TABLE OF CONTENTS

ROOF DRAINS TABLE OF CONTENTS Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF

More information

Cast Iron Floor Outlets - Materials Care, Maintenance, Installation & Specifying/Ordering

Cast Iron Floor Outlets - Materials Care, Maintenance, Installation & Specifying/Ordering Cast Iron Floor Outlets - Materials Care, Maintenance, Installation & Specifying/Ordering Materials All Harmer cast iron floor gullies are cast to material grade EN-GJL-00 to BS EN, painted internally

More information

CI/SfB (52) Drainage Systems. frostdrainage.com

CI/SfB (52) Drainage Systems. frostdrainage.com CI/SfB (52) Drainage Systems frostdrainage.com Contents Introduction 3-7 What we do 3 Technical dvice and Support 4 dvantages of Frost Drainage Systems 5 Some UK Projects Some Worldwide Projects 7 Floor

More information

FLOOR AND AREA DRAINS

FLOOR AND AREA DRAINS Pictorial Index Product Recommendations Floor Drain Selection Factors Load Rating Grate Free Area Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations FLOOR AND AREA

More information

Aluminium Roof Outlets - Application Details

Aluminium Roof Outlets - Application Details Harmer AV Vertical Threaded Outlet in Warm Roof Concrete Deck Construction with Asphalt Waterproofing 2 coats of asphalt Isolating membrane Harmer AV Vertical Threaded outlet Rigid insulation ADP Adaptor

More information

ACO Building Drainage Products ACO Cast Iron Floor Drains with Nickel Bronze Tops ACO Cast Iron Cleanouts with Nickel Bronze Tops

ACO Building Drainage Products ACO Cast Iron Floor Drains with Nickel Bronze Tops ACO Cast Iron Cleanouts with Nickel Bronze Tops CO Building Drainage Products CO Cast Iron Floor Drains with Nickel Bronze Tops CO Cast Iron Cleanouts with Nickel Bronze Tops CO. The future of drainage. CO Systems FZE Established in 2006, CO Systems

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1423 - STORM DRAINAGE PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

CI/SfB Oct 12 (52.5) Uniclass L7314

CI/SfB Oct 12 (52.5) Uniclass L7314 CI/SfB Oct 12 (52.5) Uniclass L7314 Bailey Flow-therm Product Selector A RANGE OF QUALITY AND ROBUST RAINWATER OUTLET AND VENTILATION SYSTEMS FOR FLAT ROOFS, MANUFACTURED FROM RIGID POLYURETHANE. Bailey

More information

SECTION DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

SECTION DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing). SECTION 15421 DRAINS AND CLEANOUTS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. Division 7 - Thermal and Moisture Protection. 2. 15410 - Piping (Plumbing). 1.02 SUBMITTALS A. Product Data: Submit

More information

CI/SfB Oct 12 (52.5) Uniclass L7314

CI/SfB Oct 12 (52.5) Uniclass L7314 CI/SfB Oct 12 (52.5) Uniclass L7314 Bailey Flow-therm Product Selector A RANGE OF QUALITY AND ROBUST RAINWATER OUTLET AND VENTILATION SYSTEMS FOR FLAT ROOFS, MANUFACTURED FROM RIGID POLYURETHANE. Bailey

More information

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing). SECTION 15421 DRAINS AND CLEANOUTS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. Division 7 - Thermal and Moisture Protection. 2. 15410 - Piping (Plumbing). 1.02 SUBMITTALS A. Product Data: Submit

More information

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing). SECTION 15421 DRAINS AND CLEANOUTS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. Division 7 - Thermal and Moisture Protection. 2. 15410 - Piping (Plumbing). 1.02 SUBMITTALS A. Product Data: Submit

More information

Elite Rainwater Drainage Outlets from Marley Alutec

Elite Rainwater Drainage Outlets from Marley Alutec Elite Rainwater Drainage Outlets from Marley lutec n Innovative Multi-Purpose Modern Flat Roof & alcony Drainage System ROOF OUTLET SYSTEMS Product guide Compatible with LL waterproofing systems Unrivalled

More information

FUNCTIONAL REQUIREMENTS

FUNCTIONAL REQUIREMENTS FUNCTIONAL REQUIREMENTS FUNCTIONAL REQUIREMENTS 7.6 BALCONIES Workmanship i. All workmanship must be within the tolerances defined in Chapter 1 of this manual. ii. All work is to be carried out by a technically

More information

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions.

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions. SECTION 07710 MANUFACTURED ROOF SPECIALTIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Roof drains for new roofing. B. Roof drains for reroofing. C. Roof drains for retrofitting into existing roof drains.

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping specialties:

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping specialties: SECTION 221423 - STORM DRAINAGE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following storm drainage piping specialties: 1. Backwater valves. 2. Cleanouts. 3. Roof drains.

More information

DRAINS: & , S COMMERCIAL. Drains: Bath, Shower & Commercial

DRAINS: & , S COMMERCIAL. Drains: Bath, Shower & Commercial DRAINS: BATH,, SHOWER &, S COMMERCIAL SHOWER DRAINS GENERAL PURPOSE DRAINS FIT-FLUSH CLEAN-OUTS BATH WASTES BATH WASTES KITS/PARTS/COMPONENTS BATH DRAIN BODIES/ASSEMBLIES BATH DRAIN KITS/PARTS/COMPONENTS

More information

Shower and Floor Gullies SECTION

Shower and Floor Gullies SECTION Shower and Floor Gullies SECTION Shower and Floor Gullies 9 General Information McAlpine has responded to market conditions and customer demand by producing an extensive range of Shower and Floor Gullies

More information

SECTION STORM DRAINAGE PIPING SPECIALTIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS

SECTION STORM DRAINAGE PIPING SPECIALTIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS SECTION 22 14 23 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

MAG-MIFAB. Floor Drains/Grated Outlets Balcony, Roof & Side Drains/Outlets Cleanouts

MAG-MIFAB. Floor Drains/Grated Outlets Balcony, Roof & Side Drains/Outlets Cleanouts MAG-MIFAB Floor Drains/Grated Outlets Balcony, Roof & Side Drains/Outlets Cleanouts Image is for illustrative purposes, not all products available. MAG-MIFAB Floor Drains/Grated Outlets F1100 SERIES Adjustable

More information

Student Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties:

Student Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties: SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Cleanouts. 2. Floor drains. 3. Roof flashing

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties:

Union County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties: SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Cleanouts. 2. Floor drains. 3. Roof flashing

More information

CI/SfB (52) May Linear Drainage

CI/SfB (52) May Linear Drainage Uniclass EPIC CI/SfB (52) May 2007 Linear Drainage Aprivately owned U.K. company with more than forty years experience in the industry, Wade is established as a leading manufacturer of quality drainage

More information

Pluvia Product and Installation Guide

Pluvia Product and Installation Guide Pluvia Product and Installation Guide Valid from 1. April 2013 Siphonic System Elements Guide All Geberit Pluvia rainwater systems in the UK and Ireland are installed by fully trained Approved Installers,

More information

LIT-058 ROOFGUARD-2017 The Uncloggable Roof Drain Dome Go to for the most current product specification sheets.

LIT-058 ROOFGUARD-2017 The Uncloggable Roof Drain Dome Go to  for the most current product specification sheets. www.mifab.com The Uncloggable Roof Drain Dome ROOFGUARD-2017 Go to www.mifab.com for the most current product specification sheets. DESIGNED, ASSEMBLED AND PACKAGED IN THE USA LIT-058 MIFAB, Inc. 1321

More information

Specification Drainage

Specification Drainage Specification Drainage SD0119 Customer Guide Froet Drain Addendum Effective January 1, 2019 Replaces All Previous Price Lists SD0119 FROET ADDENDUM FROET SELL SHEET 3 100C 15" DIAMETER DEEP SUMP DUAL

More information

Sommerhein AB Box 1089 S Lidingö SWEDEN Tel: Fax: website:

Sommerhein AB Box 1089 S Lidingö SWEDEN Tel: Fax: website: Sommerhein AB Box 1089 S-18122 Lidingö SWEDEN Tel: 00 46 8 7653929 Fax: 00 46 8 7310088 e-mail: per@sommerhein.com website: www.sommerhein.com CI/SfB (52) X Agrément Certificate No 95/3179 Designated by

More information

SECTION PLUMBING SPECIALTIES

SECTION PLUMBING SPECIALTIES SECTION 15430 PLUMBING SPECIALTIES PART 1 GENERAL The requirements of the GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS and Division 1, General Requirements, Apply to the work specified in this section.

More information

ACO Building Drainage

ACO Building Drainage Uniclass L7315 Cl/SfB (52.5) April 2017 Drainage Systems Product catalogue ACO DeckLine 125 Galvanised Steel Channel System Our built environment is becoming ever more complex. Applications are becoming

More information

Drain DESIGN & INSTALLATION GUIDE 316L STAINLESS STEEL INDUSTRIAL FLOOR DRAINS & LINEAR DRAINAGE CHANNELS

Drain DESIGN & INSTALLATION GUIDE 316L STAINLESS STEEL INDUSTRIAL FLOOR DRAINS & LINEAR DRAINAGE CHANNELS DESIGN & INSTALLATION GUIDE 316L STAINLESS STEEL INDUSTRIAL FLOOR DRAINS & LINEAR DRAINAGE CHANNELS KEMDRAIN TM STAINLESS INDUSTRIAL FLOOR DRAINS AND LINEAR CHANNELS, OFFERING ALL THE BENEFITS OF 316L

More information

BLÜCHER Channel Linear drainage

BLÜCHER Channel Linear drainage BLÜCHER Channel Linear drainage K E E P I N G U P T H E F L O W S T A I N L E S S S T E E L D R A I N A G E S Y S T E M S 2 SEE BLÜCHER CONTENTS BLÜCHER CHANNEL 4 STANDARD CHANNEL RANGE 6 Standard channels

More information

The Uncloggable Roof Drain Dome LIT-058

The Uncloggable Roof Drain Dome LIT-058 www.mifab.com ROOFGUARD -018 CERTIFIED MANAGEMENT SYSTEM ISO 9001:015 Go to www.mifab.com for the most current product specification sheets. DESIGNED, ASSEMBLED AND PACKAGED IN THE USA The Uncloggable

More information

Aluminium Floor Outlets - Materials Care, Maintenance, Installation & Specifying/Ordering

Aluminium Floor Outlets - Materials Care, Maintenance, Installation & Specifying/Ordering Aluminium Floor Outlets - Materials Care, Maintenance, Installation & Specifying/Ordering Maintenance The bodies of Harmer Floor Drains have a smooth polyester coating which prevents adherence of foreign

More information

roofing ROOFING Design of the base ROOFING DETAILS

roofing ROOFING Design of the base ROOFING DETAILS DETAILS The general arrangement details and the principles to be followed at skirtings, upstands, abutments, verges, gutters and expansion joints are as details illustrated. SELECTION PARAMETERS It is

More information

FLOOR DRAINS GENERAL INFORMATION

FLOOR DRAINS GENERAL INFORMATION FLOOR DRAINS 11 FLOOR DRAINS GENERAL INFORMATION All floor drains and rodding eyes are made from stainless steel V2A (AISI 304) or V4A (AISI 316). The floor drain type depends on the load, amount of drained

More information

component developments Stainless Steel Industrial Floor Drainage

component developments Stainless Steel Industrial Floor Drainage component developments Stainless Steel Industrial Floor Drainage Component Developments What we do We design, manufacture and supply standard, adapted and bespoke stainless steel building products. We

More information

DIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM

DIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM DIVISION 22 PLUMBING PART 1 GENERAL 1.01 DESCRIPTION A. Provide a complete system of soil, waste, and vent piping to fixtures and equipment, including traps, floor drains and cleanouts, extending to a

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15420 DRAINAGE AND VENT SYSTEMS PART 1 DESIGN DIRECTIVES 1.1 DESIGN CRITERIA A. All cleanouts above finished (accessible and non-accessible) ceilings shall be extended to the floor above. B. Do

More information

Light-Metal Roof Edge, Raised

Light-Metal Roof Edge, Raised NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED

More information

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

SECTION PLUMBING SPECIALTIES

SECTION PLUMBING SPECIALTIES PART 1 GENERAL 1.1 SCOPE SECTION 22 20 00 PLUMBING SPECIALTIES A. Work consists of all plumbing work indicated on drawings and specified herein. B. Also included are all fees and permits for installation

More information

1 ½

1 ½ HOW TO SELECT A FLOOR DRAIN Floor and area drains receive liquid from surrounding areas and by the attached piping, convey the liquid to the storm or sanitary drainage system. Floor drains are primarily

More information

DRAFT. Draft Bill of Quantities. Drainage

DRAFT. Draft Bill of Quantities. Drainage Draft Bill of Quantities September 2015 STORM DRAINAGE INFORMATION Measurement notes Drawings used : WYG (80) 140 Rev T1, D-(80) 001 Rev T1, D-(80) 002 Rev T1, D-(80) 003 Rev T1 and D-(80) 004 Rev T1 All

More information

ACO Building Drainage

ACO Building Drainage Uniclass L73144 CI/Sf6 S2 (52.5) November 2011 Drainage Systems ACO Building Drainage Product catalogue and specifiers design guide ACO Building Drainage Watertight Rainwater Outlets for Flat Roofs and

More information

SECTION 13. A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications.

SECTION 13. A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications. SECTION 13 PIPE, TUBE AND PART 1 - GENERAL 1.01 DESCRIPTION A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications. 1.02 QUALITY ASSURANCE

More information

112mm. 117x75mm Polyflow. 130x70mm Ogee 68mm Round 65mm Square. 112mm Half Round 68mm Round. 65mm. Round. 112mm. 117x75mm Polyflow

112mm. 117x75mm Polyflow. 130x70mm Ogee 68mm Round 65mm Square. 112mm Half Round 68mm Round. 65mm. Round. 112mm. 117x75mm Polyflow Gutter and Systems A comprehensive range of fittings accompanies each rainwater profile in Polypipes unrivalled product range, to provide the specifier and installer with a complete roof drainage solution.

More information

Bridge Drainage Systems

Bridge Drainage Systems Bridge Drainage Systems 2 Bridge drains made of cast iron, durable and reliable in use 3 One of the most important preconditions for the perfect functioning of bridge structures is the fast drainage of

More information

Birco. Water Linear Management Drainage Design Guide Birco Introduction Linear Drainage Channel. Grate Drainage System

Birco. Water Linear Management Drainage Design Guide Birco Introduction Linear Drainage Channel. Grate Drainage System Birco Grate Drainage System Robust and durable. Proven and trusted. Low to high capacity. Wide range of channels and gratings. Constant and inbuilt fall channels. Manufactured in accordance with BS EN

More information

Specification Drainage Products. Cleanout Selec on

Specification Drainage Products. Cleanout Selec on Cleanouts Specification Drainage Products Cleanout Selec on Cleanout Selection The common cleanout is an important, but frequently neglected item in the plumbing system. The cleanout provides access to

More information

Drainage. Specification Drainage Products 2013 Catalog and Price List. Effective June 1, watts.ca

Drainage. Specification Drainage Products 2013 Catalog and Price List. Effective June 1, watts.ca Drainage Specification Drainage Products 2013 Catalog and Price List Effective June 1, 2013 watts.ca WATTS Drainage Terms & Conditions FREIGHT TERMS: All shipments are F.O.B. shipping point. Shipments

More information

Agrément Certificate 2011/393

Agrément Certificate 2011/393 Agrément Certificate 2011/393 Copyright Agrément South Africa, August 2011 Subject: Geberit Pluvia Syphonic Roof Drainage System The master copy of this document appears on the website: www.agrement.co.za

More information

FarBo PRODUCT OVERVIEW Rainwater Outlets from Fixfast

FarBo PRODUCT OVERVIEW Rainwater Outlets from Fixfast FarBo PRODUCT OVERVIEW Rainwater Outlets from Fixfast FarBo system Containing and flow control in water management Efficient water management is critical to the longevity of a building. Rainfall onto flat

More information

ACO Marine. ACO Scuppers - ACO Channels ACO Drainage Systems for Shipbuilding and Offshore Installations

ACO Marine. ACO Scuppers - ACO Channels ACO Drainage Systems for Shipbuilding and Offshore Installations ACO Marine ACO Scuppers - ACO Channels ACO Drainage Systems for Shipbuilding and Offshore Installations Basic characteristic Through a consistent and effective product development, ACO Marine has developed

More information

Siphonic. Drain System. Engineered Water Solutions for Today s Building Design Needs

Siphonic. Drain System. Engineered Water Solutions for Today s Building Design Needs Siphonic Drain System Engineered Water Solutions for Today s Building Design Needs Table of Contents History of Siphonic Systems 2 Components of Siphonic Systems 2 Specifics of Siphonics 2 Conventional

More information

External drainage. Roof, yard and car park drains. Drainage by design!

External drainage. Roof, yard and car park drains. Drainage by design! External drainage Roof, yard and car park drains Drainage by design! 2 Dallmer GmbH + Co. KG Roof drains for gravity drainage... 8 Overflow drainage for gravity drainage... 9 Gravity roof drains with fire

More information

Drainage with system SELF structural elements

Drainage with system SELF structural elements Drainage with system SELF structural elements Drainage channels, boot scrapers, yard sumps for the house, yard and garden Contents 04 ANRIN SELF structural elements Material / Application / Properties

More information

G-FIRE GROOVED COUPLINGS

G-FIRE GROOVED COUPLINGS G-FIRE GROOVED COUPLINGS Figure 5 G-FIRE Rigid Page 5 Figure 5 Flexible Page GRINNELL are designed for grooved end pipe and are available in nominal sizes of 25mm (") to 3mm (2") including BS, and ISO

More information

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE SECTION 13 34 00 METAL SHADE STRUCTURE PART 1 - GENERAL 1.01 STRUCTURE TYPE A. Structure shall be free standing rigid frame and gable roof with slopes as indicated. Structure shall also include foundation,

More information

Diffused Aeration Piping Equipment

Diffused Aeration Piping Equipment 1.0 General 1.1. The specifications in this section include all components of the Diffused Aeration System with the exception of the individual diffuser units. Refer to additional specification sections

More information

CONTINUED ON FOLLOWING PAGE

CONTINUED ON FOLLOWING PAGE Date Description of Change Pages / Sections Modified ID 08/05/17 Entire document - mgl PART 1 - INTRODUCTION 1.1 This standard refers to the following plumbing specialties. A. Drains, B. Hydrant and Hose

More information

InoxSabiana 25 Flues. Stainless Steel Double Wall

InoxSabiana 25 Flues. Stainless Steel Double Wall Cert. n 0545/5 Flues Stainless Steel Double Wall Introduction and main constructional characteristics Double Wall, Stainless Steel Flues The is the result of innovative development based on over 0 years

More information

Uniclass L7315. CI/SfB (52.5) X

Uniclass L7315. CI/SfB (52.5) X Uniclass L7315 CI/SfB (52.5) X CAROFLOW Floor Drainage outlets are manufactured to the highest standards to give superb products that combine superior corrosion resistant materials with an aesthetically

More information

SECTION FACILITY STORM DRAINAGE

SECTION FACILITY STORM DRAINAGE PART 1 - GENERAL 1.1 DESCRIPTION SECTION 22 14 00 Storm drainage systems, including piping and all necessary accessories as designated in this section. 1.2 RELATED WORK A. Penetrations in rated enclosures:

More information

AS Interpretation of External Waterproofing as it applies to Melbourne, Class 1 buildings

AS Interpretation of External Waterproofing as it applies to Melbourne, Class 1 buildings AS4654.2 Interpretation of External Waterproofing as it applies to Melbourne, Class 1 buildings Climate Zone: 6 Wind Class: N1 Membrane Types: Liquid Applied Class II and Class III as defined and tested

More information

Drexus Pave Drain. Linear Channel. Water Management. Water Linear Management Drainage Design Guide Drexus Pave Drain Linear Drainage Channel

Drexus Pave Drain. Linear Channel. Water Management. Water Linear Management Drainage Design Guide Drexus Pave Drain Linear Drainage Channel Linear Channel Water Management Linear Channel Drexus Pave Drain Textured Silver Grey Textured Charcoal Textured Buff D400 Yorkstone, Scoutmoor Mid Grey Granite Silver Grey Granite Drexus Pave Drain Concrete

More information

BOURNEMOUTH planter. Street Design Limited Unit 35 Hayhill Industrial Estate Barrow upon Soar Leicestershire LE12 8LD

BOURNEMOUTH planter. Street Design Limited Unit 35 Hayhill Industrial Estate Barrow upon Soar Leicestershire LE12 8LD UK street furniture designers & manufacturers BOURNEMOUTH planter As UK based, designers and manufacturers, Street Design can manufacture and supply the Bournemouth circular all metal planters, to suit

More information

CYCLONE Steel gutters and rainwater system. A steel rainwater system designed to protect in the toughest weather

CYCLONE Steel gutters and rainwater system. A steel rainwater system designed to protect in the toughest weather STEEL AGAINST THE STORM UNICLASS L7314/P414 CI/Sfb (52.5) AUGUST 2015 CYCLONE Steel gutters and rainwater system A steel rainwater system designed to protect in the toughest weather Saint-Gobain PAM UK

More information

A. This Section includes the following sanitary drainage piping specialties:

A. This Section includes the following sanitary drainage piping specialties: Page 221319-1 SECTION 221319 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S SPECIFICATIONS - DETAILED PROVISIONS Section 11294 - Stainless Steel Sluice Gates C O N T E N T S PART 1 - GENERAL... 1 1.01 SUMMARY... 1 1.02 REFERENCES... 1 1.03 DEFINITIONS... 1 1.04 DESIGN REQUIREMENTS...

More information

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only) Outline NBS Specification Protec System to PVC Single Ply (Waterproofing Only) This document is a guide to assist in the production of tender documents only and is not project specific. A site survey is

More information

ARCHITECTURAL SPECIFICATIONS

ARCHITECTURAL SPECIFICATIONS ARCHITECTURAL SPECIFICATIONS I. GENERAL 1. System Description: 1.1 Size The raised access floor system shall consist of 600mm x 600mm x 3mm modular steel cement panels/ cementitious panels / cement filled

More information

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

The syphonic roof drainage system

The syphonic roof drainage system The syphonic roof drainage system P. C. Chang, Mr. Abstract The Geberit Pluvia roof drainage system is based on the ingenious gravity-induced vacuum principle. Consisting of HDPE roof outlets, pipes and

More information

Technische Grundlagen

Technische Grundlagen Technische Grundlagen 47 Technical bases Technical bases for point drainage ACO bath drains are used in areas where there is a demand for functional long-life solutions with high flow volumes combined

More information

Roofgard Paving Support System

Roofgard Paving Support System Roofgard Paving Support System CI/SfB (47) January 2007 Adjustable paving support system for paved and raised deck applications One of a range of Roofgard accessories specially designed to meet the exacting

More information

G U T T E R SY S T E M

G U T T E R SY S T E M GUTTER SYSTEM Why should I buy steel gutters? A guttering system is a roof accessory that is used to quickly discharge hundreds of liters of water during a downpour. The Struga steel guttering system is

More information

Installation instructions. LORO-ATTIKASTAR siphonic drains

Installation instructions. LORO-ATTIKASTAR siphonic drains instructions with clamping flange, for pressure flow for bituminous or plastic roof sealing sheets, according to EN 1253, steel, hot-dip galvanised consist of the drain body and the stainless steel suction

More information

SECTION ALUMINUM HANDRAIL SYSTEMS

SECTION ALUMINUM HANDRAIL SYSTEMS SECTION 05520 ALUMINUM HANDRAIL SYSTEMS PART 1 - GENERAL 1.01 SUMMARY A. Section includes aluminum handrails and railings. B. Related Work: 1. Section 03300 - Cast-in-Place Concrete C. References: 1. American

More information

CI/SfB (52.5) September 2005 Uniclass L7315. ACO EuroCover Stainless steel composite double sealed access covers

CI/SfB (52.5) September 2005 Uniclass L7315. ACO EuroCover Stainless steel composite double sealed access covers CI/SfB (2.) September 200 Uniclass L731 ACO EuroCover Stainless steel composite double sealed access covers ACO Building Drainage ACO Building Drainage Our built environment is becoming ever more complex.

More information

200 Series In-Slab Pool Fittings

200 Series In-Slab Pool Fittings 230 Series nti-vortex Plate 2-2 231 Series Sump 2-3 234 Series Sump 2-4 236 Series Sump 2-5 253 Series Overflow 2-6 255 Series Overflow/Drain 2-7 261 Series Vacuum Fitting 2-8 263 Series Eyeball Fitting

More information

The system: it supports 3 load classes (A15, B125, C250) in compliance with Standard EN 1433

The system: it supports 3 load classes (A15, B125, C250) in compliance with Standard EN 1433 The system: it supports 3 load classes (A15, B125, C250) in compliance with Standard EN 1433 it is made up of a channel - entirely made from HD-PE - which needs no strengthening frame it has a wide usable

More information

.2 Section Waste Management and Disposal

.2 Section Waste Management and Disposal Issued 2006/08/01 Section 15401 Plumbing Specialties and Accessories Page 1 of 10 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal.3

More information

SPRI RD-1 Performance Standard for Retrofit Drains

SPRI RD-1 Performance Standard for Retrofit Drains SPRI RD-1 Performance Standard for Retrofit Drains 1. INTRODUCTION This standard is a reference on retrofit roof drains which are designed for installation in existing drain plumbing on existing roofs.

More information

Canadian Catalogue & Price List

Canadian Catalogue & Price List 2017 DRAINAGE Canadian Catalogue and Price List Canadian Catalogue & Price List Specification Drainage Products Effective October 30, 2017 All prices supersede previous issues, are temporary and subject

More information

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10 CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES 283 Chapter 10 FUNCTIONAL REQUIREMENTS FUNCTIONAL REQUIREMENTS 10.1 PLASTERWORK Workmanship i. All workmanship must be within the tolerances

More information

M-Span Shelving. Distributed by R.J. Cox Engineering

M-Span Shelving. Distributed by R.J. Cox Engineering M-Span Shelving The all new M-Span shelf is designed to be easy to clean and last a lifetime for an affordable price. Made by over moulding a sub frame with Food Grade Polypropylene to produce a strong

More information

FLOOR DRAINS FLOOR DRAINS. SUPER-FLO Features

FLOOR DRAINS FLOOR DRAINS. SUPER-FLO Features SUPER-FLO Features The two-piece Floor Drain bodies which are designed to be combined with any adjustable strainers offered by JOSAM have proven features which make them the easiest and quickest drains

More information

A. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms.

A. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms. SECTION 22 13 00 FACILITY SANITARY SEWERAGE PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

GE Commercial Floor Drains, Wastes & Cleanouts

GE Commercial Floor Drains, Wastes & Cleanouts GE Commercial Floor Drains, Wastes & Cleanouts www.galvinengineering.com.au ISO9001 Lic0133 SAI Global Introduction INDEX INTRODUCTION General Information... 2 Ordering & Specification Details... 3-4 Our

More information

ACO Building Drainage Products

ACO Building Drainage Products ACO Building Drainage Products ACO Building Drainage Product overview brochure Roof and floor drains Stainless steel linear drains Bathroom drainage Threshold drainage Grease separators Stainless steel

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 077200 - ROOF ACCESSORIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES CONTENTS 10.1 PLASTERWORK 10.2 2 ND AND 3 RD FIX FINISHES FUNCTIONAL REQUIREMENT 10.1 Plasterwork Workmanship Design Technical Manual TS-011-09-010412 i. All workmanship must be within defined tolerances

More information

AS The External Waterproofing Membranes Standard

AS The External Waterproofing Membranes Standard AS 4654-2 The External Waterproofing Membranes Standard NOTE This external waterproofing standard contains solutions for problems which have not been addressed in other countries. CONFORMANCE CONDITIONS

More information

Ice Rink Renovation & New Clubhouse

Ice Rink Renovation & New Clubhouse SECTION 22 13 19 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Think Safety, Think Safesite O&M - KEEGUARD

Think Safety, Think Safesite O&M - KEEGUARD Think Safety, Think Safesite O&M - KEEGUARD Safesite Guardrail Systems SAFESITE GUARDRAIL SYSTEMS Safesite s guardrail systems including System 2000 and KeeGuard have been designed specifically to provide

More information

Taking drainage to the next level. FDT VarioGully

Taking drainage to the next level. FDT VarioGully Taking drainage to the next level. FDT VarioGully FDT VarioGully-System Flashing collars for Emergency overflow socket 100 mm Gravel stop / Emergency overflow bitumen Rhepanol fk grey Rhepanol fk black

More information