Uni-Just & Stak-Cap Pedestal System
|
|
- Stella Powell
- 5 years ago
- Views:
Transcription
1 Tile Tech Pedestal Uni-Just & Stak-Cap Pedestal System Single Model Design PVC Pipe Adjustable Screw Adjustable Self-Leveling Pat. # 8,453,39 & Pat. Pen Stackable HYBRID PEDESTAL SYSTEM - TECHNICAL DETAILS
2 TILE TECH PEDESTAL SYSTEM TABLE OF CONTENTS Toll Free: Fax: COMPONENTS LIST 6. DIAGONAL PERIMETER APPLICATION 4. COMPONENT ASSEMBLY INSTRUCTIONS STAK-CAP PEDESTALS 7. LOW HEIGHT PEDESTAL APPLICATION 5. INSTALLATION INSTRUCTIONS STAK-CAP PEDESTALS 8. DRAIN PEDESTAL APPLICATION 6. COMPONENT ASSEMBLY INSTRUCTIONS UNI-JUST PEDESTALS 9. PERIMETER EDGE RESTRAINT METAL FLASHING AND WOOD FASCIA CONTAINMENT 7. INSTALLATION INSTRUCTIONS UNI-JUST PEDESTALS 20. PERIMETER EDGE RESTRAINT STEP-DOWN AND GREEN ROOF CONTAINMENT 8. BASE SLOPE COMPENSATION 2. STEP-DOWN PEDESTAL APPLICATION 9. UNI-SHIM APPLICATION 22. IPE WOOD TILE APPLICATION 0. PEDESTAL COMBINATION & CONFIGURATION 23. WOOD TILES 20X20 DETAILS. SAMPLE DECK LAYOUT - OVERVIEW 24. WOOD TILES 24X24 DETAILS 2. SAMPLE INITIAL INSTALLATION 25. JOIST DECK PEDESTAL APPLICATION 3. THRESHOLD PEDESTAL APPLICATION 4. RADIUS PEDESTAL APPLICATION 26. WIN-LOC PAVER PAVER LOCK DOWN SYSTEM FOR WIND UPLIFT. 27. HEX-TRAY PAVER SNOW MELT SYSTEM. 5. CORNER PEDESTAL APPLICATION COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 2
3 TILE TECH PEDESTAL SYSTEM COMPLETE PRODUCT LINE & COMPONENTS LIST PRODUCT LINE MODEL NUMBER DESCRIPTION SPACERS /8 & /4 ALLOW FOR /8 SPACING GAP BETWEEN PAVERS FOR DRAINAGE. TABS A PERFORATED FOR EASY REMOVAL. UNI-SHIM - /8 & /6 USED FOR FINE TUNING OF INDIVIDUAL PAVERS. CAN BE USED ON TOP OR BOTTOM OF PEDESTALS. CAN BE STACKED & BROKEN IN TO QUARTERS OR HALVES. STAK-CAP USED OF LOW HEIGHT REQUIREMENTS. ROTATE AND STACK CAPS FOR SLOPE & HEIGHT ADJUSTMENT. CAN ALSO BE USED WITH PVC PIPE TO REACH 6 MAX. UNI-CAP SELF-LEVELING & ADJUSTABLE IN ANY DIRECTION FROM 0% TO 4% SLOPE. ALIGN & LOCK TO UNI- INSERT. UNI-INSERT -75 (3/4 ) UNI-INSERT -50 (-/2 ) UNI-COLLAR USED FOR SCREW HEIGHT ADJUSTABILITY OF PEDES- TAL. SCREWS IN TO UNI-COLLAR. PROVIDES ADDI- TIONAL 3/4 OF HEIGHT ADJUSTMENT IN ADDITION TO PVC PIPE. USED FOR SCREW HEIGHT ADJUSTABILITY OF PEDES- TAL. SCREWS IN TO UNI-COLLAR. PROVIDES ADDI- TIONAL -/2 OF HEIGHT ADJUSTMENT IN ADDITION TO PVC PIPE. USED FOR SCREW HEIGHT ADJUSTABILITY OF PEDES- TAL SYSTEM. COMPRESSION FITS ON TO TOP END OF PVC PIPE. UNI-BASE BASE SLOPE PLATE (BSP) BUFFER PAD USED AS BASE OF PEDESTAL SYSTEM. COMPRESSION FITS ON TO END OF PVC PIPE. CAN ALSO BE USED WITH UNI-INSERT FOR LOW HEIGHT APPLICATIONS. LARGE SURFACE AREA PROVIDE ADDED STABILITY. USED FOR SLOPE COMPENSATION AT BASE OF PEDESTALS. EACH PLATE COMPENSATES FOR /4 PER FOOT (2%) SLOPE AND ADDS 3/8 TO THE OVERALL HEIGHT OF PEDESTAL. MAXIMUM OF FOUR PLATES MAY BE STACKED FOR COMPEN- SATION OF UP TO PER FOOT (0-8%) SLOPE. PROVIDES PROTECTION TO WATERPROOFING MEM- BRANE FROM WEAR AND PROVIDES SLIP RESISTANCE TO PEDESTAL. ATTACHES TO BOTTOM OF BASE. ALIGN PERIMETER NOTCHES WITH CHALK LINES. COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 3
4 STAK-CAP PEDESTAL SYSTEM COMPONENT ASSEMBLY INSTRUCTIONS. HEIGHT ADJUSTMENT FROM /2 TO 2-¼ & SLOPE ADJUSTMENT FROM 0% TO 5% ROTATE PRODUCT CHARACTERISTICS: EACH CAP WILL COMPENSATE FOR UP TO /8 PER FOOT SLOPE (%) & ADD 3/8 TO THE OVERALL HEIGHT OF A PEDESTAL. PVC PIPE SHOULD NOT BE USED. ROTATE ONE CAP RELATIVE TO ANOTHER BY ALIGNING THE ALPHABETS TO CHANGE SLOPE. A & A WILL REACH MAXIMUM SLOPE AND A & E WILL CANCEL SLOPE. A MAXIMUM OF 5 CAPS CAN BE STACKED WITH TOTAL SLOPE OF 5/8 PER FOOT (5%) & WITH TOTAL HEIGHT OF 2-¼ INCLUDING THE USE OF BUFFER PADS. STACK CONFIGURATION CHART: CAP = 5/8 HIGH /8 PER FOOT % MAX 2 CAPS = HIGH /4 PER FOOT 2% MAX (A+A) 3 CAPS = -3/8 HIGH 3/8 PER FOOT 3% MAX (A+A+A) 4 CAPS = -7/8 HIGH /2 PER FOOT 4% MAX (A+A+A+A) 5 CAPS = 2-/4 HIGH 5/8 PER FOOT 5% MAX (A+A+A+A+A) PVC + 2 CAPS = VARIABLE HEIGHT 0% MAX PVC + 3 CAPS = VARIABLE HEIGHT % MAX PVC + 4 CAPS = VARIABLE HEIGHT 2% MAX PVC + 5 CAPS = VARIABLE HEIGHT 3% MAX COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 4
5 STAK-CAP PEDESTAL INSTRUCTIONS INSTALLATION INSTRUCTIONS - /2 to 2-¼ HIGH & 0%-5% SLOPE ROTATE Notch STACK. Chalk grid lines starting from door threshold based on paver size plus /8 gap. 2. Position Buffer Pads on chalk grid lines using the v-notch as a reference point. 3. Using a laser determine final height of pedestals from ½ to 2-¼ high. Consider in calculation the Buffer Pads as /8 thick. Spacer Tabs Laser line Notch Chalk line 4. Assemble by rotating & aligning alphabets of one Stak-Cap with the Stak-Cap bellow it for slope compensation. 5. Complete assembly by snapping on Spacer Tabs in order to provide proper spacing of pavers. Spacer tabs are perforated and can be ripped or cut off. 6. Position pedestal under laser line and align Buffer Pad notch with chalk line. Orient the pedestal assembly so that the top Stak-Cap pair high side points towards decline of slope. Final project grade Level Level Leveling Shims Laser line Deck 7. Adjust final pedestal height by using Uni-Shims whole or in segments at the top of pedestal assembly. 8. Use a spirit level to check level and use additional half or quarter Uni-Shims for fine tuning of individual corners of pavers. 9. For IPE wood insert the lock washer in to the kurf-cut on the corners of wood tiles then insert screw through lock washer and hand tighten. 3. CONTRACTOR S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 5
6 UNI-JUST PEDESTAL SYSTEM COMPONENT ASSEMBLY INSTRUCTIONS. HEIGHT ADJUSTMENT FROM 2-/4 TO 24 & SLOPE ADJUSTMENT FROM 0% TO 4% SPACER TABS - /8 TABS CAN BE BROKEN OFF ALLOW DIFFERENT PAVING CONFIGURATION UNI-CAP SELF-LEVELING & ADJUSTABLE IN ANY DIRECTION FROM 0% TO 4% SLOPE UNI-INSERT - 3/4 & -/2 SCREW ADJUSTMENT FROM 3/4 TO -/2 OF ADDITIONAL HEIGHT UNI-COLLAR SNAPS ON TO END OF 4 ø SDR35 PVC PIPE 4 ø SDR35 PVC PIPE USER SUPPLIED & CUT TO REQUIRED HEIGHT UNI-BASE SNAPS ON TO END OF 4 ø SDR35 PVC PIPE OR CAN BE USED WITH UNI-INSERT BUFFER PAD USED UNDER BASE TO PROVIDE SLIP RESISTANCE, NOISE DAMPENING & MEMBRANE PROTECTION PRODUCT CHARACTERISTICS: ADJUSTABLE HEIGHT FROM 2-/4 TO 24 WITH USE OF 4 ø SDR35 PVC PIPE. SELF-LEVELING CAP AUTOMATICALLY ADJUST SLOPE FROM 0% TO 4%. SCREW ADJUSTABLE WHILE PEDESTALS ARE LOADED FOR FINAL HEIGHT ADJUSTMENT OF -/2 RESISTANT & IMPERVIOUS TO FREEZE-THAW, WATER, MOLD, ACID & ULTRAVIOLET DETERIORATION. RESISTANT TO TEMPERATURES BETWEEN -22 F AND +250 F. LARGE FOOT PRINT SPREADS WEIGHT OVER ROOFING MEMBRANE AND SUBSTRATE BUFFER PADS PROVIDE NOISE DAMPENING, SLIP RESISTANCE AND PROTECTION TO ROOFING MEMBRANE AND SUBSTRATE. MAXIMUM DESIGN CAPACITY OF 2,OOO LBS PER PEDESTAL. COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 6
7 UNI-JUST PEDESTAL INSTRUCTIONS INSTALLATION INSTRUCTIONS /2 to 24 HIGH & 0%-4% SLOPE. Chalk grid lines starting from door threshold based on paver size plus /8 gap. 2. Using a laser determine final height of pedestals. Deduct ¼ for base & cap assembly. Measure & mark PVC pipe to be cut. 3. Cut PVC pipe to required height with a 2 chop saw. Using sand paper remove any burrs from cut ends. Laser line Notch Chalk line 4. Assemble by inserting cut PVC pipe in to Uni-Base and Uni-Collar in to other end of PVC pipe. Screw Uni-Insert in to Uni-Collar minimum of 2 threads. 5. Complete assemble by rotating & aligning Uni-Cap with Uni-Insert. Align & attach Buffer Pad to Uni-Base. 6. Position pedestal under laser line and align Buffer Pad notch with chalk line. Final project grade Final project grade Allen Key Laser line Level Laser line Deck Deck 7. Adjust final pedestal height by using Allen Key from top to screw up or down Uni-Insert. 8. Use a spirit level to level Uni-Cap in any direction. 9. Use Allen Key to fine tune loaded pedestal for a perfect level & height. 3. CONTRACTOR S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 7
8 BASE SLOPE PLATE BASE SLOPE ADJUSTMENT FROM 0 TO (0-8%) PER FOOT SLOPE. STACK AND ROTATE ONE PLATE RELATIVE TO ANOTHER TO COMPENSATE FOR A RANGE OF SLOPES. POINT BOTH FINGER TABS DOWN HILL FOR MAXIMUM SLOPE COMPENSATION. 90 FINGER TABS BUFFER PAD FOR BASE LEVELING, BASE SLOPE PLATES (BSP) CAN BE STACKED UNDER UNI-BASE AND EACH PLATE COMPENSATES FOR /4 PER FOOT (2%) SLOPE AND ADDS 3/8 TO THE OVERALL HEIGHT OF PEDESTAL. A MAXIMUM OF FOUR PLATES MAY BE STACKED BELOW A PEDESTAL IN ORDER TO COMPENSATE FOR UP TO PER FOOT (0-8%) SLOPE. ALWAYS USE A BUFFER PAD UNDER COMPLETE PEDESTAL ASSEMBLY. BASE SLOPE PLATE APPLICATION - SECTION DETAILS UNI-JUST PEDESTALS 2 TO 22 HIGH 0% SLOPE 2% SLOPE x BASE PLATE 4% SLOPE 2 x BASE PLATE 6% SLOPE 3 x BASE PLATE 8% SLOPE 4 x BASE PLATE COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 8
9 UNI-SHIM APPLICATION /8 & /6 RIGID SHIMS USED ON TOP AND UNDER PEDESTAL UNI-SHIM /8 & /6 A UNI-SHIM /8 OR /6 MAY BE PLACED ON TOP OF EACH PEDESTAL. UNIQUE INTERLOCKING FEATURE ALLOWS SHIMS LOCK TO EACH OTHER AND TO PEDESTAL TOPS, NO GLUING REQUIRED. SHIMS MAY BE USED WHOLE OR BROKEN INTO SEGMENTS FOR FINE TUNING & LEVELING. MAY BE CUT INTO SEGMENTS UNI-SHIM TOP OF PEDESTAL UNI-SHIMS MAY BE PLACED ON TOP OF PEDESTALS FOR MINOR LEVELING OF PAVERS WITH THICKNESS VARIATIONS. USE NO MORE THAN 3 SHIMS STACKED PER CORNER. UNI-SHIM UNDER PEDESTAL PLACE UNI-SHIMS, WHOLE OR IN SEGMENTS, UNDER EACH PEDESTAL IN A STAIR STEP FASHION TO COMPENSATE FOR SLOPING SUBSTRATES. USE NO MORE THAN 2 SHIMS, AND ADHERE THEM TO EACH OTHER WITH CONSTRUCTION ADHESIVE. ADHERE W/ POLYURE- THANE CONSTRUCTION ADHESIVE DO NOT ADHERE TO SUBSTRATE COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 9
10 STAK-CAP & UNI-JUST PEDESTALS SAMPLE PEDESTAL CONFIGURATION & COMBINATION COMPENSATION FROM /2 TO 36 HIGH & 0% TO 4% SLOPE SPACER FIXED HEIGHT /8 STAK-CAP HEIGHT 3/8 SLOPE % Max STAK-CAP X2 HEIGHT SLOPE 2% Max STAK-CAP X3 HEIGHT -3/8 SLOPE 3% Max STAK-CAP X4 HEIGHT -7/8 SLOPE 4% Max STAK-CAP X5 HEIGHT 2-¼ SLOPE 5% Max UNI-JUST w/o PVC PIPE HEIGHT 2-¼ TO 3 SLOPE 0% TO 4% UNI-JUST w/ PVC PIPE HEIGHT 3 TO 3-¾ SLOPE 0% TO 4% UNI-JUST w/ PVC PIPE HEIGHT VARIABLE MAX 36 SLOPE 0% TO 4% COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 0
11 SAMPLE DECK LAYOUT OVERVIEW OF PEDESTAL PLACEMENT SEE ENLARGED SECTION PLANS: A DOOR THRESHOLD PEDESTAL PLACEMENT E LOW THRESHOLD PEDESTAL PLACEMENT B RADIUS PERIMETER PEDESTAL PLACEMENT F ROOF DRAIN PEDESTAL PLACEMENT C CORNER PERIMETER PEDESTAL PLACEMENT D DIAGONAL PERIMETER PEDESTAL PLACEMENT HP E A D B F HP LP SLOPE /4 PER RD FOOT LP RD C LP - LOW POINT HP - HIGH POINT RD - ROOF DRAIN COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page
12 2 SAMPLE INITIAL INSTALLATION USING T SHAPED PATTERN MAXIMUM /8 GAP AT PERIMETER HP REMOVE SPACER TABS FROM PERIMETER PEDESTALS AS NECESSARY START PAVER AND PEDESTAL INSTALLATION FROM HIGH POINT OR THRESHOLD USING WHOLE PAVER START PAVER AND PEDESTAL INSTALLATION IN T SHAPED PATTERN LP LP - LOW POINT HP - HIGH POINT RD - ROOF DRAIN DETERMINE CAVITY HEIGHT AT ALL THRESHOLDS, DRAINS AND HIGH POINTS. DEDUCT THE THICKNESS OF THE PAVERS FROM THE MEASURED DISTANCE BETWEEN THE TOP OF THE MEMBRANE AND THE TOP OF THE PAVERS TO DETERMINE THE PEDESTAL HEIGHT NEEDED FOR EACH LOCATION. USE A LASER LEVEL TO MARK THE TOP OF PEDESTAL ELEVATION AROUND THE DECK. PLAN PAVER & PEDESTAL LAYOUT PATTERN BEFORE STARTING, BY MARKING GUIDELINES ON THE ROOF IF NEEDED. USING THE GUIDELINES INSTALL A T SHAPED PORTION OF THE NEW DECK STARTING FROM THE THRESHOLD OR HIGH POINT. PAVERS ON BOTH ROWS OF THE T SHOULD BE ADJUSTED TO THE CORRECT HEIGHT AND LEVELED BEFORE PROCEEDING. INSTALLATION ON ALL SIDES OF THE T CAN THEN PROCEED AT THE SAME TIME. COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 2
13 A THRESHOLD PEDESTAL APPLICATION ENLARGED PLAN VIEW & SECTION DETAILS ENLARGED PLAN VIEW SLOPE DIRECTION UNI-JUST PEDESTAL PERIMETER GAP /8 MAX SLOPE UNI-JUST PEDESTAL VALLEY LINE THRESHOLD PEDESTAL APPLICATION - SECTION DETAILS PERIMETER GAP /8 MAX REMOVE EXTRA SPACER TAB ON PERIMETER PEDESTAL BOTTOM OF THRESHOLD TOP OF PAVER DECK TOP OF PEDESTAL TOP OF WATERPROOFING UNI-JUST PEDESTALS 2 TO 24 HIGH & 0%-4% SLOPE SLOPE TO DRAIN SDR35 PVC ROOF DECK THRESHOLD & PEDESTAL HEIGHT WILL VARIE INSULATION 60psi MIN SELF-LEVELING CAP 0% TO 4% SLOPE COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 3
14 B RADIUS PEDESTAL APPLICATION ENLARGED PLAN VIEW & SECTION DETAILS ENLARGED PLAN VIEW ADHERE EDGE CUT PAVER TO TOP OF PEDESTAL WITH SILICONE ADHESIVE UNI-JUST PEDESTAL REMOVE EXTRA TABS ON PERIMETER PEDESTAL TO SUPPORT PAVER EDGES SLOPE PERIMETER GAP /8 MAX RADIUS PEDESTAL APPLICATION - SECTION DETAILS PERIMETER GAP /8 MAX REMOVE EXTRA SPACER TAB ON PERIMETER PEDESTAL RE-INSERT REMOVED TABS & ADHERE WITH SILICONE UNI-JUST PEDESTAL ADJUSTABLE /2 TO 24 HIGH TOP OF PAVER DECK TOP OF PEDESTAL TOP OF WATERPROOFING SLOPE TO DRAIN ADHERE EDGE CUT PAVERS TO PEDESTAL TOP WITH SILICONE ADHESIVE SELF-LEVELING CAP 0% TO 4% SLOPE ROOF DECK INSULATION 60psi MIN COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 4
15 C CORNER PEDESTAL APPLICATION ENLARGED PLAN VIEW & SECTION DETAILS ENLARGED PLAN VIEW UNI-JUST PEDESTAL ADHERE EDGE CUT PAVER TO TOP OF PEDESTAL WITH SILICONE ADHESIVE REMOVE EXTRA TABS ON PERIMETER PEDESTALS TO SUPPORT PAVER EDGES PERIMETER GAP /8 MAX CORNER PEDESTAL APPLICATION - SECTION DETAILS PERIMETER GAP /8 MAX RE-INSERT REMOVED TABS & ADHERE WITH SILICONE REMOVE EXTRA SPACER TAB ON PERIMETER PEDESTALS UNI-JUST PEDESTALS ADJUSTABLE /2 TO 24 HIGH TOP OF PAVER DECK TOP OF PEDESTAL TOP OF WATERPROOFING SLOPE TO DRAIN ADHERE EDGE CUT PAVERS TO PEDESTAL TOP WITH SILICONE ADHESIVE ROOF DECK SELF-LEVELING CAP 0% TO 4% SLOPE INSULATION 60psi MIN COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 5
16 D DIAGONAL PERIMETER APPLICATION ENLARGED PLAN VIEW & SECTION DETAILS ENLARGED PLAN VIEW UNI-JUST PEDESTAL ADHERE EDGE CUT PAVER TO TOP OF PEDESTAL WITH SILICONE ADHESIVE REMOVE EXTRA TABS ON PERIMETER PEDESTALS TO SUPPORT PAVER EDGES SLOPE PERIMETER GAP /8 MAX DIAGONAL PEDESTAL APPLICATION - SECTION DETAILS PERIMETER GAP /8 MAX REMOVE EXTRA SPACER TAB ON PERIMETER PEDESTALS RE-INSERT REMOVED TABS & ADHERE WITH SILICONE UNI-JUST PEDESTALS ADJUSTABLE /2 TO 24 HIGH TOP OF PAVER DECK TOP OF PEDESTAL TOP OF WATERPROOFING SLOPE TO DRAIN ADHERE EDGE CUT PAVERS TO PEDESTAL TOP WITH SILICONE ADHESIVE SELF-LEVELING CAP 0% TO 4% SLOPE ROOF DECK INSULATION 60psi MIN COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 6
17 E LOW HEIGHT PEDESTAL APPLICATION ENLARGED PLAN VIEW & SECTION DETAILS ENLARGED PLAN VIEW STACK & ROTATE PEDESTAL CAPS TO ADD HEIGHT AND CHANGE SLOPE USE UNI-SHIM FOR FINE TUNING OF INDIVIDUAL PAVERS HP STAK-CAP PEDESTAL SPACER TABS /8 SLOPE PERIMETER GAP /8 MAX STACKABLE CAPS (5 MAX) /2 TO 2-/4 HIGH 0% TO 5% SLOPE B REMOVE EXTRA TABS ON PERIMETER PEDESTALS TO SUPPORT PAVER EDGES B LOW HEIGHT PEDESTAL APPLICATION - SECTION DETAILS REMOVE EXTRA SPACER TAB ON PERIMETER PEDESTALS RE-INSERT REMOVED TABS & ADHERE WITH SILICONE STAK-CAP (5 MAX) /2 TO 2-/4 HIGH 0% TO 5% SLOPE TOP OF PAVER DECK TOP OF PEDESTAL TOP OF WATERPROOFING PERIMETER GAP /8 MAX ROOF DECK SLOPE TO DRAIN USE UNI-SHIM ON TOP OR UNDER PEDESTAL FOR FINE HEIGHT & SLOPE ADJ. INSULATION 60psi MIN 4. CONTRACTOR S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 7
18 F DRAIN PEDESTAL APPLICATION ENLARGED PLAN VIEW & SECTION DETAILS ENLARGED PLAN VIEW UNI-JUST PEDESTALS ADJUSTABLE HEIGHT 2-/4 TO 24 0% TO 4% SLOPE A STAK-CAPS PEDESTALS /2 TO 2-/4 HIGH 0% TO 5% SLOPE 5 UNITS MAX ROOF DRAINS OVER DRAIN PAVERS OR STEEL PLATE (/4 MIN) USE ADDITIONAL PEDESTAL A DRAIN PEDESTAL APPLICATION - SECTION DETAILS OVER DRAIN PAVERS OR STEEL PLATE (/4 MIN) USE ADDITIONAL PEDESTAL CLAULKING ROOF WALL JUNCTURE USE UNI-SHIMS ON TOP OR UNDER PEDESTAL FOR FINE HEIGHT & SLOPE ADJ. STAK-CAPS PEDESTALS /2 TO 2-/4 HIGH UNI-JUST PEDESTALS 2-/4 TO 24 HIGH METAL COUNTERFLASHING WATERPROOF MEMBRANE SLOPE TO DRAIN SLOPE TO DRAIN ROOF DECK 60psi MIN INSULATION ROOF DRAIN COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 8
19 PERIMETER EDGE RESTRAINT OPTIONS METAL FLASHING AND WOOD FASCIA CONTAINMENT DETAILS METAL FLASHING CONTAINMENT TWO PIECE EDGE METAL LEDGER BOARD DECK SCREWS PRE-FINISH METAL 22GA. GALV. METAL FLASHING MUST FULLY CONTAIN PAVER AND TIE BACK INTO BUILDING WALL OR PARA- PET. BOTTOM OF METAL FLASHING CAN BE BENT OR CUT ABOVE SUBSTRATE TO ALLOW WATER TO DRAIN. ROOF DECK WOOD FASCIA CONTAINMENT FASCIA BOARD FLUSH WITH TOP OF PAVER LEDGER BOARD DECK SCREWS FASCIA BOARD MUST FULLY CONTAIN PAVER AND TIE BACK INTO BUILDING WALL OR PARA- PET. BOTTOM OF FASCIA BOARD CAN BE CUT ABOVE SUBSTRATE TO ALLOW WATER TO DRAIN. ROOF DECK COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 9
20 PERIMETER EDGE RESTRAINT OPTIONS STEP-DOWN AND GREEN ROOF CONTAINMENT DETAILS STEP-DOWN CONTAINMENT FASCIA BOARD FLUSH WITH TOP OF PAVER VARIABLE RISER HEIGHT (PER CODE) LEDGER BOARD UNI-JUST PEDESTALS 2-/4 TO 24 HIGH ROOF DECK LEDGER BOARD IS FASTENED TO VERTICAL PVC PIPE OF PEDESTAL WITH DECK SCREWS. THE FASCIA BOARD IS FASTENED TO THE LEDGER BOARD WITH FINISH SCREWS AND FUNCTIONS AS CONTAINMENT TO PREVENT LATERAL MOVEMENT OF PAVERS. GREEN ROOF CONTAINMENT ENGINEERED GREEN ROOF SOIL ROOF DECK FILTER FABRIC L-CHANNEL WITH DRAIN HOLES COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 20
21 2 STEP-DOWN PEDESTAL APPLICATION STEP-DOWN PEDESTAL APPLICATION SECTION DETAILS LEDGER BOARD IS FASTENED TO VERTICAL PVC PIPE OF PEDESTAL WITH DECK SCREWS. THE FASCIA BOARD IS FASTENED TO THE LEDGER BOARD WITH FINISH SCREWS AND FUNCTIONS AS CONTAINMENT TO PREVENT LATERAL MOVEMENT OF PAVERS. FASCIA BOARD FLUSH WITH TOP OF PAVERS LEDGER BOARD VARIABLE RISER HEIGHT (PER CODE) UNI-JUST PEDESTALS 2-/4 TO 24 HIGH ROOF DECK COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 2
22 WOOD TILE & PEDESTAL APPLICATION TRANSITION, ALIGNMENT & LOCK DOWN DETAILS DECK SCREW -/4 LONG LOCK WASHER INSERT THE LOCK WASHER IN TO THE KURF CUT BETWEEN THE UPPER SLAT AND BOTTOM RAIL OF 3 WOOD PAVERS. INSERT THE 4th PAVER IN TO THE 4TH CORNER. ONCE ALL 4 PAVERS ARE TIGHTLY IN PLACE INSERT DECK SCREW (-/4 LONG) THROUGH LOCK WASHER AND HAND TIGHTEN IN TO PEDESTAL TOP UNTIL ALL 4 PAVERS ARE SECURELY FASTENED TO THE PEDES- TAL. DO NOT OVER TIGHTEN. UNI-JUST PEDESTAL IPE WOOD & PAVER TRANSITION AND ALLIGNMENT UNI-SHIM USED FOR INDIVIDUAL WOOD / PAVER ALIGNMENT TILE TECH IPE WOOD COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 22
23 IPE WOOD TILES DETAILS 20 x 20 x -/2 Toll Free: Fax: CROSS MEMBER TOP VIEW 3. CONTRACTOR S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 23
24 IPE WOOD TILES DETAILS 24 x 24 x -5/8 CROSS MEMBER TOP VIEW 3. CONTRACTOR S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 24
25 JOIST DECK & PEDESTAL APPLICATION JOIST DECK INSTALLATION DETAILS & SPANNING CHART JOIST HANGER UNI-SHIM JOIST SPAN JOIST PLATE DECK PLANKS JOIST JOIST HANGER JOIST SPACING PEDESTAL SPACING BEAM SIZE -4x OR 2-2x 2" O.C. JOIST SPACING UNI-JUST PEDESTAL WITH JOIST CAP JOIST SIZE JOIST SPAN BEAM SIZE PEDESTAL SPACING 2x6 0' - 0" 4x6 OR (2) 2x6 24" O.C. 2x8 2x0 3' - 2" 6' - 0" 4x8 OR (2) 2x8 4X0 OR (2) 2x0 24" O.C. 24" O.C. 6" O.C. JOIST SPACING JOIST SIZE JOIST SPAN BEAM SIZE PEDESTAL SPACING 2x6 9' - " 4x6 OR (2) 2x6 24" O.C. NOTE: THIS DIAGRAM AND CHART ARE FOR CONVENIENCE ONLY. COMPATIBILITY OF DECKING MATERIAL AND JOIST SPANNING WILL VARY DEPENDING ON THE TYPE / SIZE OF CONCRETE PAVERS, WOOD OR COMPOSITE MATERIALS BEING USED. ADDITIONALLY CODE REQUIREMENTS VARY PER LOCATION AND IT IS THE INSTALLERS RESPONSIBILITY TO ENSURE DECK MEETS CODE REQUIREMENTS. 2x8 2' - 0" 4x8 OR (2) 2x8 24" O.C. 2x0 5' - 2" 4X0 OR (2) 2x0 24" O.C. 20" O.C. JOIST SPACING JOIST SIZE JOIST SPAN BEAM SIZE PEDESTAL SPACING 2x6 7' - " 4x6 OR (2) 2x6 24" O.C. 2x8 0' - 2" 4x8 OR (2) 2x8 24" O.C. 2x0 2' - 5" 4X0 OR (2) 2x0 24" O.C. COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 25
26 WIND-LOC PAVER & PEDESTAL APPLICATION PAVER LOCK DOWN SYSTEM DETAILS. PLAN AND PROFILE VIEW Toll Free: Fax: WIND-LOC SCREW WIND-LOC PLATE WIND-LOC BASE WIND-LOC PEDESTAL IS MADE OF HIGH IMPACT POLYPRO- PYLENE & ABS AND IS MADE TO LOCK THE PAVER SYSTEM TOGETHER AND PREVENT WIND UPLIFT. POSITION AND LEVEL HYBRID PEDESTAL SYSTEM ON GRID LINES. SET THE WIND-LOC BASE ON TOP OF THE PEDESTAL SYSTEM AND SET WIND-LOC PAVERS ON TO WIND-LOC BASE. BE SURE TO ALIGN RECESS ON BACK SIDE OF PAVER WITH THE DOMES ON THE WIND-LOC BASE. POSITION & ALIGN WIND-LOC PLATE ON TO WIND-LOC PAVERS IN A DIAMOND CONFIGU- RATION. INSTALL WIND-LOC SCREW IN TO WIND-LOC BASE WITH A HEX BIT. TIGHTEN DOWN TO 80 PSI. DO NOT OVER TIGHTEN. WIND-LOC PAVERS Pat. # 8,453,39 & Pat. Pen WIND-LOC - PROFILE VIEW WIND-LOC SCREW WIND-LOC BASE WIND-LOC PLATE Patent Pending WIND-LOC PAVERS UNI-JUST PEDESTAL COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 26
27 HEX-TRAY SNOW MELT SYSTEM Tile Tech Inc. PAVER SNOW MELT SYSTEM DETAILS. PLAN AND PROFILE VIEW National Distribution Toll Free: Tel: Fax: TILE TECH PORCELAIN HEAT TRANSFER PLATE PEX TUBING CHANNELS HEX-TRAY FOAM INSULATION HEX-TRAY SNOW MELT SYSTEM COMPONENTS INCLUDES A HONEYCOMB STRUCTURAL TRAY WITH PEX TUBING CHANNELS, A FOAM INSULATION PANEL, ALUMINUM HEAT TRANSFER PLATE AND USER SUPPLIED ½ PEX TUBING. PRE ASSEMBLE THE FOAM INSULATION PANEL TO THE BACK OR BOTTOM SIDE OF THE HEXTRAY AND SECURE WITH SUPPLIED CORK-SCREW. POSITION AND LEVEL HYBRID PEDESTAL SYSTEM ON TO GRID LINES. PLACE SEMI ASSEMBLED HEX-TRAY ON TO PEDESTAL SYSTEM. LEVEL & SECURE FOUR ADJACENT CORNERS TO PEDESTAL SYSTEM USING HEX-LOCK DISK AND SECURE WITH DECK SCREW (-/4 LONG). POSITION AND ALIGN HEAT TRANSFER PLATE TO TOP OF HEXTRAY. AT TERMINATION POINTS AND WALLS, CUT BACK HEAT TRANSFER PLATE TO EXPOSE THE U SHAPED CHANNELS IN ORDER TO LOOP BACK PEX TUBING. INSTALL PEX TUBING AND TEST FOR LEAKS. INSTALL PORCELAIN PAVERS. Hex-Tray Snow Melt System PEX TUBING CHANNELS HYBRID PEDESTAL SYSTEM Pat. # 8,850,753 & Pat. Pen Patent Pending HEX-TRAY SNOW MELT - PROFILE VIEW TILE TECH PORCELAIN PAVERS PEX TUBING HEAT TRANSFER PLATE HEX-TRAY FOAM INSULATION COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 27
28 Tile Tech Pedestal HP-D 0/5 205 Tile Tech Inc Visit our website at for complete design details and photo gallery MADE IN AMERICA
IPE WOOD DECK TILES National Distribution SPEC - SECTION 07760
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
More informationROOF PAVER SYSTEM National Distribution SPEC - SECTION 07760
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
More informationTile Tech Porce-PaveTM Paving America one step at a time!
Tile Tech Porce-PaveTM Paving America one step at a time! ULTRA-THIN 2 cm LIGHTWEIGHT MANUFACTURER OF PORCELAIN DECK PAVERS 2 T a b l e o f C o n t e n t s Uses & Applications Commercial & Residential
More informationAGA Roof Deck Pavers. AGA Concrete Paver. Technical. Pavers: Hydraulically pressed concrete pavers: 460 tons of pressure.
Cut Sheet AGA Roof Deck Pavers AGA Concrete Paver Overview: AGA Standard sized pavers are manufactured to meet project requirements. Custom: we offer a variety of custom sizes and a mixture of colors and
More informationTile Tech IPÊ-Tile. Paving America one step at a time! MANUFACTURER OF IPÊ WOOD TILES & ADJUSTABLE PEDESTAL SYSTEMS
Tile Tech IPÊ-Tile TM Paving America one step at a time! MANUFACTURER OF IPÊ WOOD TILES & ADJUSTABLE PEDESTAL SYSTEMS 2 T a b l e o f C o n t e n t s Applications Roof Decks Plaza Decks Pool Decks... 3
More informationMbrico Tile Rooftop/Raised Floor Installation Guidelines
Mbrico Tile Rooftop/Raised Floor Installation Guidelines *The following information is the installation guidelines Mbrico recommends when installing the Mbrico Tile Rooftop system. Installation guidelines
More informationSECTION PRECAST CONCRETE PAVERS AND PEDESTAL LOK DOWN SYSTEM
SECTION 07555 PRECAST CONCRETE PAVERS AND PEDESTAL LOK DOWN SYSTEM PART ONE: GENERAL 1.1 SUMMARY A. Concrete paver and pedestal support system with Lok Down devices are to be placed over roofing/waterproofing
More informationHILLSBOROUGH TOWNSHIP CODE ENFORCEMENT
HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT SAMPLE GUIDE FOR RESIDENTIAL DECKS revised 7 16 Call before you dig! 1 800 272 1000 New Jersey One Call. Utility Mark Out. THIS GENERIC GUIDE IS NOT ALL INCLUSIVE
More informationLevel.It L-Series Specification SECTION Plastic Structural Assemblies PART 1 GENERAL
701 Osage Street, Bldg 2, Unit 120 Phone 303-892-0400 Denver, CO 80204 Toll Free 800-333-4234 www.bisonip.com Fax 303-825-5988 The Bison Innovative Products (Bison) Level.It adjustable pedestal has a broad
More informationDETAIL INSTRUCTION No. 1
BEFORE BEGINNING INSTALLATION, PLEASE READ THROUGH ALL INSTRUCTIONS. Uncrate shipment and check against packing list to insure all materials are included before beginning installation. If any discrepencies
More informationSECTION ROOF PEDESTAL PAVER SYSTEM
SECTION 07 76 00 ROOF PEDESTAL PAVER SYSTEM ************************************************************************************************************************ Edit entire master to suit project requirements.
More informationContract18. Vitrified paving FLAT ROOF BALCONY ROOF TERRACE DISPLAY AREA
Contract18 Vitrified paving FLAT ROOF BALCONY ROOF TERRACE DISPLAY AREA Contract 18 Vitrified Paving Installation Methods Installation Method 1 Dry Installation Using Our Range of Paving Support Pads Installation
More information4 EXTREME FOUNDATION PANELS
4 EXTREME FOUNDATION PANELS For House Crawl Space On Concrete Footings 1. The type of soil is a factor in determining foundation construction details such as footing design, backfill, and drainage provisions.
More information2018
2018 www.peygran.com RAISED FLOOR PEDESTALS 37 Raised Floor Pedestals Raised floor Pedestals Peygran Pedestals for external use are a solution for projects in which floating, technical, raised or registrable
More informationI N S T A L L A T I O N
I N S T A L L A T I O N G U I D E mesasupport.com Version 2.3 MESA Support 2019 C O N T E N T S Decking Pedestal Overview 01 Calculating Materials Decking Pedestals 02 Laying Decking Pedestals 04 Using
More informationTypical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading
CONSTRUCTION TIP SHEET 5 w/ 60 lb Live Loading April 1, 2017 This Tip Sheet reflects code requirements of the 2015 International Residential Code (IRC) with Washington State Amendments which update the
More informationSPECIFICATIONS Section Cantilevered Walkway Cover
Part 1: General 1.1 Related Documents SPECIFICATIONS Section 107301 Cantilevered Walkway Cover A. The requirements of Division 1 specifications shall apply to work specified in the section. 1.2 Engineering
More informationCITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO
SECTION 07220 - ROOF INSULATION PART 1 - GENERAL 1.01 DESCRIPTION A. Work included: The Roofing Contractor will provide all polyisocyanurate insulation and high density wood fiber roof insulation (tapered
More informationVersadjust V-Series Specification SECTION Plastic Structural Assemblies PART 1 GENERAL
701 Osage Street, Bldg 2, Unit 120 Phone 303-892-0400 Denver, CO 80204 Toll Free 800-333-4234 www.bisonip.com Fax 303-825-5988 The Bison Innovative Products (Bison) Versadjust (V-Series) adjustable pedestal
More informationVersadjust V-Series Specification SECTION Plastic Structural Assemblies PART 1 GENERAL
701 Osage Street, Bldg 2, Unit 120 Phone 303-892-0400 Denver, CO 80204 Toll Free 800-333-4234 www.bisonip.com Fax 303-825-5988 The Bison Innovative Products (Bison) Versadjust (V-Series) adjustable pedestal
More information10 EXTREME BASEMENT PANELS
10 EXTREME BASEMENT PANELS On Granular Footings 1. The type of soil is a factor in determining foundation construction details such as footing design, backfill, and drainage provisions. Soils are classified
More informationElevations Roof Deck and Tile Systems
Elevations Roof Deck and Tile Systems THE SYSTEM Roof Decks and other poorly ventilated deck applications present a unique set of challenges for a designer and or builder. Iron Woods Elevations Deck Tiles
More informationskydeck usa, LLC pavers. pedestals. green roof SKYJACK Adjustable Pedestal System Taking the P.I.A. out of paver installs
skydeck usa pavers. pedestals. green roof SKYJACK Adjustable Pedestal System Taking the P.I.A. out of paver installs Our 37 years of roofing experience led us to design the simplest, easiest, fastest installing
More informationTypical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading
CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading April 1, 2017 This Tip Sheet reflects code requirements of the 2015 International Residential Code (IRC) with Washington State Amendments which
More informationSpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 )
SpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 ) WARNING - When unpacking SpaVault, DO NOT discard styrofoam pieces, these are not packaging materials. Step 1 Excavation Important:
More informationRoofgard Paving Support System
Roofgard Paving Support System CI/SfB (47) January 2007 Adjustable paving support system for paved and raised deck applications One of a range of Roofgard accessories specially designed to meet the exacting
More informationRoof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208
Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details D-3 Roof Details M-1 Mechanical - Roof Plan M-2 Mechanical - Details Roof Key Plan
More informationCONCRETE TILE PAVERS
Section 32 14 13 CONCRETE TILE PAVERS (1995 MasterFormat Section 02780) Note: This guide specification for the U.S. is for the installation of concrete tile paving units whose thickness are less than the
More informationLight-Metal Roof Edge, Raised
NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED
More informationSECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.
SECTION 10 5300 ALUMINUM WALKWAY COVERS Part 1 General 1.01 Related Documents A. The requirements of Division 1 specifications shall apply to work specified in the section. 1.02 References A. International
More informationBison Innovative Products 1975 W. 13 th Ave. Phone February 2012 P.O. Box Toll Free Denver, CO Fax
Bison Innovative Products 1975 W. 13 th Ave. Phone 303-892-0400 February 2012 P.O. Box 40246 Toll Free 800-333-4234 Denver, CO 80204 Fax 303-825-5988 www.bisonip.com info@bisonip.com SECTION 02870 SITE
More informationNortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1
16 May 2014 Page 1 PART 1 GENERAL 1.1 DESCRIPTION This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories
More informationRADIANT PANEL SYSTEM PLANNING & INSTALLATION. Roth Radiant Heating Systems
RADIANT PANEL SYSTEM PLANNING & INSTALLATION Roth Radiant Heating Systems INTRODUCTION The Roth Radiant Panel System was developed for the wood frame houses of the North American and Scandinavian markets.
More informationShower Tray - Timber Floors
Shower Tray - Timber Floors Assembly information Assembly information The JACKOBOARD shower unit consists of a floor panel and a drainage system. Both components are coordinated with each other and form
More informationExterior System installation instructions
Exterior System installation instructions 11/20/14 WPS ES-400 & 500 INSTALLATION INSTRUCTION. The WPS ES-400 & 500 systems Façade panels are designed for use as an external wall cladding in conjunction
More informationBuilding permits are not required for patios made of concrete or pavers on grade.
DECKS CITY OF BEMIDJI BUILDING DEPARTMENT (218) 759-3573 www.ci.bemidji.mn.us This handout is intended only as a guide and is based in part on the 2007 Minnesota State Building Code, Bemidji City Ordinances
More informationSuper-Compact Ceiling Hanger Model KSCH Patent Pending Ceiling Isolation Theory: Resiliently suspended ceiling systems are designed to minimize floor impact noise and airborne sound transmissions through
More informationInstallation Instructions
Installation Instructions Roof edge trim profile Series TA-4F multi-piece extruded aluminium profile front face height series TA-4F: 150-200 mm with patented 4F brackets height-adjustable, horizontally
More informationZS880 Linear Shower Drain Installation Instructions
Introduction PATENT PENDING The Zurn ZS880 Stainless Steel Linear Shower Drain incorporates a simple approach to bathroom shower design, when compared to traditional point-drain applications. The linear
More informationWEIGHT PER PIECE (LBS.)
PRODUCT DESCRIPTION DATA SHEET 04 73 19-US BASIC USE ProGUARD DP is intended to be installed over sheathing and waterproofing over steel or wood studs or over concrete masonry units or poured concrete
More informationCOUNTY BLOCK. Construction Guidelines on County Block Steps. Special Considerations When Building Steps. Natural Beauty Absolute Strength
Construction Guidelines on County Block Limits of Liability This County Block Installation Guide provides general information about the product, including installation procedures, technical and engineering
More informationSPECIFICATIONS Section Gable Walkway Covers
Part 1: General 1.1 Related Documents SPECIFICATIONS Section 107303 Gable Walkway Covers A. The requirements of Division 1 specifications shall apply to work specified in the section. 1.2 Engineering Design
More informationINSTALLATION CHECKLIST 2 ND EDITION. Fox Blocks Abbott Drive Omaha, NE
Fox Blocks INSTALLATION CHECKLIST ND EDITION Fox Blocks Installation Checklist: ND Edition 6110 Abbott Drive Omaha, NE 6110-69-6 WWW.FOXBLOCKS.COM INSTALLATION CHECKLISTS The Checklists on the following
More informationFreeStyle Linear Drain with Full Mortar Bed Adapter Kit
FreeStyle Linear Drain with Full Mortar Bed Adapter Kit U.S. Patent No. 8,474,068 Patents Pending: Canada & EP Publication No. 2354339 Discard Linear Drain installation instructions and refer to these
More information1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers.
SECTION 071413 HOT FLUID APPLIED RUBBERIZED ASPHALT WATERPROOFING PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels.
More informationDEXERDRY INSTALLATION INSTRUCTIONS - PAGE - 1
DEXERDRY INSTALLATION INSTRUCTIONS - PAGE - 1 Tools and Items Needed Drill/power screwdriver 1/8 drill bit Table saw Circular saw with carbide-tip blade Rubber mallet Chisel or board straightener tool
More informationASHLEY AVE. PARKING GARAGE CHILLER TOWER ROOF REPAIRS
NORTH CHILLER TOWER ROOF R-00 COVER SHEET R-0 ROOF PLAN DRAWING INDEX VICINITY MAP SITE MAP ASHLEY AVE. PARKING GARAGE CHILLER TOWER ROOF REPAIRS 58 ASHLEY AVE. CHARLESTON, SC 90 STATE PROJECT NO. H5-D5
More informationADJUSTABLE PIPING SUPPORT PRODUCT BROCHURE
ADJUSTABLE PIPING SUPPORT PRODUCT BROCHURE OVERVIEW REVOLUTIONARY VERSATILE EFFICIENT The Roof Top Blox is a revolutionary roof top support block system that works with height extension rods, securing
More informationTypical Deck Details. Albemarle County, Virginia. Based on the 2012 Virginia Residential Code
Albemarle County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code The design details in this document apply to residential decks only. Framing requirements are limited to single
More informationRoof Replacement. Notes: T-1 (Title Page) 709 Bull Street Columbia, South Carolina. University of South Carolina. Callcott Social Science
Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details S1.0 Safety Anchor Plan Building 709 Bull Street Columbia, 1 10/13 T-1 (Title Page)
More informationADJUSTABLE PIPING SUPPORT PRODUCT BROCHURE
ADJUSTABLE PIPING SUPPORT PRODUCT BROCHURE OVERVIEW REVOLUTIONARY VERSATILE EFFICIENT The Roof Top Blox is a revolutionary roof top support block system that works with height extension rods, securing
More informationSECTION MANUFACTURED ROOF EXPANSION JOINTS
SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationPV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual
PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual Series 200 UL Introduction Series 200 UL Introduction SnapNrack Series
More informationNRDCA GUIDELINE FOR APPLICATION of CEMENTITIOUS WOOD FIBER ROOF DECK SYSTEMS
NRDCA 600 - GUIDELINE FOR APPLICATION of CEMENTITIOUS WOOD FIBER ROOF DECK SYSTEMS The National Roof Deck Contractors Association (NRDCA) has prepared this document to provide, customers and installers,
More informationDetailed Deck Building
Detailed Deck Building PERMITS REQUIREMENTS. Building permits are required for all decks attached to a structure. Building permits can be obtained from the Building Department by filling out an application
More informationSuggested Materials and Tools:
NOISE CONTROL RESILIENT CEILING WAVE HANGER (Worldwide Patents Pending) INSTALLATION GUIDELINES Suggested Materials and Tools: Kinetics Noise Control CPT resilient tape for perimeter of room 0.875 tall
More information1 PVC or ABS drain with strainer
Patents Pending ProBase II Single-Slope Shower Base and Kit CONTENTS 1. General Information...1 2. Materials...1 3. Planning...2 4. Preparation...3 5. Layout...3 6. Install Base and Shims...4 7. Install
More informationGEOGRID CONNECTION DETAIL OLYMPIA RADIUS UNIT
PLACE TWO STANDARD CONNECTORS IN EACH UNIT AS SHOWN (VERTICAL ORIENTATION) INSERT TWO CONNECTORS PER HORIZONTALLY ORIENTED BLOCK; INSERT ONE CONNECTOR PER VERTICALLY ORIENTED BLOCK SHIM BETWEEN BLOCK COURSES
More informationROOF DETAIL RD-16 CONSTRUCTION DOCUMENTS - PHASE / PENNSYLVANIA HOUSING FINANCE AGENCY/ MAY 22, 2017 MURRAY ASSOCIATES ARCHITECTS, P.C.
3 4" ARRISCRAFT VENEER " NOMINAL AIR SPACE 2" RIGID INSULATION 8" CMU REINFORCED CONCRETE SLAB OVER METAL DECK - REFER TO STRUCTURAL DWGS 20 FIRST FLOOR 343' - 5" CONTINUOUS SEALANT TERMINATION BAR STAINLESS
More informationLeveling Foot RB210. Leg Extender RLT66
Landing for Right & Left Turn R342 ITEMS # 0254049, 0254061, 0254072, 0254076, 0016567, 0254099, 0254110, 0054116, 0254117, 0254126, 0254140, 0254150, 0254156 CUSTOM ACCESS RAMP SYSTEM MODELS # R100, R242,
More informationTremline. Fascia System. Installation Procedures
Tremline Fascia System Installation Procedures 5 TOP CAP MITERED TOP CAPS JOINT PLATE RIGHT-HAND END CAP PREFAB OUTSIDE CORNER 10 FASCIA FASCIA HOLDER 10 FASCIA CLAMPING RING DECK BRACKET SCUPPER PREFAB
More informationPAVING SLABS ON AGGREGATE BED FOR ROOF PLAZA DECKS
SECTION 32 14 13.16 PAVING SLABS ON AGGREGATE BED FOR ROOF PLAZA DECKS (1995 MasterFormat Section 02784) Note: This guide specification for the U.S. is for paving slabs used as ballast and/or paving on
More informationGroundTrac. Installation Manual
APPLICATION: The GroundTrac system is designed with a minimum amount of installed footings at greatly reduced labor. The system integrates with ordinary 1-1/2 schedule #40 galvanized water pipe. This ground
More informationA-ONE Insulated Forms Installation Manual
A-ONE Insulated Forms Installation Manual Rockford, MN www.aoneform.com www.diversifoam.com info@diversifoam.com A-ONE Manual 180426.docx Disclaimer Notice The information in the A-ONE Insulated Forms
More informationPlans created at home centers are acceptable for plan review. These computer designs do not allow homeowners to duplicate conditions at their home.
DECK PLANS BUILDING DEPARTMENT 160 LAKE STREET NORTH BIG LAKE MN 55309 (Main) 763-251-2971 / (Fax) 763-263-0133 www.biglakemn.org This handout is intended only as a guide and is based in part on the 2015
More informationBioPrism Solid Surface
Please read all instructions before installing products. STORAGE & HANDLING: Check for damage that may have occurred during transit. Keep receptor flat on pallet, as it was shipped, until ready to install.
More informationBison Innovative Products 1975 W. 13 th Ave. Phone February 2012 P.O. Box Toll Free Denver, CO Fax
Bison Innovative Products 1975 W. 13 th Ave. Phone 303-892-0400 February 2012 P.O. Box 40246 Toll Free 800-333-4234 Denver, CO 80204 Fax 303-825-5988 www.bisonip.com info@bisonip.com Versadjust V Series
More informationSECTION NON-STRUCTURAL METAL FRAMING
SECTION 09 22 16 PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories
More informationA. Pre-engineered, pre-finished extruded aluminum Pavilions.
10 73 00 SECTION Pavilions PART 1 GENERAL 1.1 SECTION INCLUDES A. Pre-engineered, pre-finished extruded aluminum Pavilions. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and Accessories. B. Section
More informationTypical Deck Details. Shenandoah County, Virginia. Based on the 2012 International Residential Code
Shenandoah County, Virginia Typical Deck Details Based on the 2012 International Residential Code The design details in this document apply to residential decks only. Framing requirements are limited to
More informationInterior Hangers. Application
Application Interior bridge deck hangers are typically fabricated using two heavy duty sheet metal end clips that have been electrically resistance welded to an appropriate sized wire or formed metal connecting
More information** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
Bison Innovative Products 2395 West 4 th Avenue Phone 303-892-0400 May 2015 Denver, CO 80223 Toll Free 800-333-4234 www.bisonip.com Fax 303-825-5988 info@bisonip.com Versadjust V Series Specification SECTION
More informationAXIOM Building Perimeter System Assembly and Installation Instructions
CEILING SYSTEMS AXIOM Building Perimeter System Assembly and Installation Instructions 1 GENERAL 1.1 Description Axiom Building Perimeter Systems (ABPS) is a pre-engineered perimeter solution to accomplish
More informationRevision Date: April 01, Premier Vinyl Enclosure
Premier Vinyl Enclosure www.urbanindustries.com 53 Urban Industries, Inc. 2008 Tools The following tools are recommended for the installation of the Premier Vinyl Enclosure and roof. 1 2 Level 1 4 Level
More informationSECTION ROOF SPECIALTIES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable
More informationSuggested Materials and Tools:
NOISE CONTROL RESILIENT CEILING WAVE HANGER (Worldwide Patents Pending) INSTALLATION GUIDELINES Suggested Materials and Tools: Kinetics Noise Control CPT resilient tape for perimeter of room 0.875 tall
More information(800) (562) A Subsidiary of the International Code Council
ICC-ES Evaluation Report ESR-1479 Issued July 1, 2009 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:
More informationBasic Suspension Systems
CEILING & WALL SYSTEMS Commercial Ceilings and Walls Solutions Guide Installing Armstrong Suspended Ceilings The ceiling system is made up of Armstrong panels which are supported by a suspension system
More informationSilva Cell. Silva Cell Two-Deep Installation Instructions. Helping Trees Live in the Urban Environment
Silva Cell T r e e R o o t G u i d e s Silva Cell Two-Deep Installation Instructions Helping Trees Live in the Urban Environment Silva Cells frames and decks should at no time be cut, drilled into, or
More informationPS 3000 Installation Manual Step-By-Step Procedures C.9. DOOR AND WINDOW OPENINGS C.9.1 PREPARE IN ADVANCE. C.9.2 VBUCK CONSTRUCTION.
C.9. DOOR AND WINDOW OPENINGS Openings for doors and windows are formed with bucks, or frames, which are constructed to the rough opening dimensions required for the doors and windows to be installed.
More informationDMX AG AIR-GAP MEMBRANE. Section Damproofing and Waterproofing
DMX AG AIR-GAP MEMBRANE Section 07 10 00 Damproofing and Waterproofing NOTE TO SPECIFIER: These specifications were current at the time of publication but are subject to change at any time without notice.
More informationROOF BALLAST MATERIALS ARCHITECTURAL CONCRETE PAVING SLABS SRS LEVELING BLOCK SYSTEM INSTALLATION PART GENERAL 1.
07555 - ROOF BALLAST MATERIALS ARCHITECTURAL CONCRETE PAVING SLABS SRS LEVELING BLOCK SYSTEM INSTALLATION PART 1.00 - GENERAL 1.01 SUMMARY: A. The work of this section consists of furnishing and installing
More informationFig. 1 - Standard Clevis Hanger
Revision 10/24/2007 Fig. 1 - Standard Clevis Hanger Component of State of California OSHPD Approved Seismic Restraints System Size Range Size 1/2" thru 36" pipe. Function Recommended for the suspension
More informationSUSPENSION REQUIREMENTS SEE DETAIL B1.2 TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 2" MODULE. SPECIFICATIONS (unless noted otherwise)
1 5 32 " 2" 27 32 " REQUIRED FOR 1 1 4 " 113 32 " 2 21 32 " SEE DETAIL B1.2 CARRIER SPAN VARIES DEPENDING ON DESIGN WIND PRESSURE 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL B1.2 12
More informationFive Stone System. Trench Depth Compactible Rock. Foundation. 57 lbs 41 lbs 31 lbs 47 lbs. Patent Pending. Approximate Weight
Five Stone System Patent Pending Introduction to the Multi-Use, Multi-Stone System The multi-use, multi-stone system has been developed to give a natural stone appearance to a manufactured system. The
More informationTypical Deck Details. Shenandoah County, Virginia. Based on the 2012 Virginia Residential Code
Shenandoah County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code The design details in this document apply to residential decks only. Framing requirements are limited to single
More informationIMPORTANT: Levelness of the walk-in floor is critical. If the floor is not level, vertical panels cannot be aligned properly.
Floor panels INSTALLATION This section is applicable only if your walk-in has a floor. If not, proceed with next section. These are probably the most important panels you will install. To install the floor
More informationUniversity of Colorado Colorado Springs. National Cybersecurity Center Roof Replacement Package CSNA Project Number
ADDENDUM NUMBER 0 TO PROJECT MANUAL AND DRAWINGS August 9, 6 OWNER: ARCHITECT: University of Colorado Colorado Springs CSNA Architects PROJECT: National Cybersecurity Center Roof Replacement Package CSNA
More informationInsulated Concrete Forms (ICFs)
Insulated Concrete Forms (ICFs) Cover of Walls & Ceilings Magazine May 2006 ICFs Getting Attention Cover of Construction Dimensions Magazine June 2006 Table of Contents Construction Dimensions Magazine
More informationHeartland Perma-Column 1841 E 1450 Rd. Lawrence, KS (785)
Perma-Column Installation Instructions Unlike any other concrete post-frame foundation system, Perma-Column Precast Concrete Piers use 10,000 psi concrete and our unique Sturdi-Wall Plus wet-set bracket
More informationINSTALLATION MANUAL for DARVOLEX D (decking) Relief profile D6 lip metal Screw 3.9x32. Smooth profile D51 underlying profile tray Clip PVC
Translation from Bulgarian INSTALLATION MANUAL for DARVOLEX D (decking) Main components Relief profile D6 lip metal Screw 3.9x32 Smooth profile D51 underlying profile tray Clip PVC Options L 35x35 L 35x65
More informationA. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.
SECTION 10530 - EXTRUDED ALUMINUM WALKWAY COVERS PART I - GENERAL.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General, Supplementary, and Special Conditions and Division
More informationRS24-10 Single-Section Skylight System
INSTALLATION INSTRUCTIONS RS24-10 VERSION 1.100316 DATED: 10/03/16 RS24-10 Single-Section Skylight System under/over seam clip double diverter US Patent D750,282 www.rnssales.com sales@rnssales.com 805.375.3980
More informationRack-in-a-BoxTM INSTALLATION MANUAL
INSTALLATION MANUAL TM 1.0 INTRODUCTION 3 2.0 PRODUCT RANGE 4 2.1 Systems 4 2.2 Accessories 4 3.0 PREPARATION FOR INSTALLATION 5 3.1 Applications 5 3.2 Tools for Installation 5 3.3 Additional Materials
More informationAL13. Intro. Vol 2 AL13. architectural panel system. Version 1. patent pending
01 AL13 Intro AL13 architectural panel system Vol 2 Version 1 www.al13.com patent pending CLAD THE WORLDTM 01 System Overview AL13 has changed the game. Our metal panel system is cut to fit and snaps together
More informationArchitectural Wall Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is
More informationAttached are examples of drawings which are intended as a GUIDE ONLY!!
RESIDENTIAL DECKS Building and Zoning Requirements (Revised 5/11/18) PERMIT SUBMITTAL CHECKLIST: Signed completed Building Permit application form. 2 Copies of a Certificate of Survey, drawn to scale indicating
More informationDECK PERMIT APPLICATION
DECK PERMIT APPLICATION APPLICANT S INFORMATION Name: Company Name: Current address: City: State: ZIP Code: Phone: Email: PROPERTY OWNER S INFORMATION Name: Property Address: Phone: E-mail: City: State:
More information