B. All materials shall be listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).
|
|
- Marcus Knight
- 5 years ago
- Views:
Transcription
1 16936 STAGE LIGHTING RIGGING (COUNTERWEIGHT) *************************************************************************************************************** SPECIFIER: CSI MasterFormat 2004 number: *************************************************************************************************************** PART 1 GENERAL 1.1 WORK INCLUDED A. Section Includes: Fabrication, furnishing, delivery, labor, and installation of the stage and lighting rigging system, and all incidental or related items necessary to complete the stage lighting rigging work. 1. Work required for this Section: a. Gridiron, head and loft block beams, and all other structural steel and miscellaneous metals not specifically called out as part of this section. b. Galleries, ladders and catwalks. B. All materials shall be listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL). 1.2 RELATED SECTIONS: Mechanical and Electrical General Requirements Stage Curtains and Tracks. 3. Division 16 - Electrical Stage Control and Lighting Equipment Stage Lightig Rigging (Pipe Grid). 1.3 REFERENCES A. American Institute of Steel Construction, Inc. (AISC). B. American Society for Testing and Materials (ASTM), latest publications: 1. A36 Specification for Carbon Structural Steel. 2. A47 Specification for Ferritic Malleable Iron Castings. 3. A48 Specification for Gray Iron Castings. 4. A53 Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless. 1.4 SUBMITTALS A. At the A/E's request, submit for review one representative sample of any device or component required under the contract. 1. The components shall be tagged with the name of the project and be shipped to the address specified by the A/E. Project No. SPECIFICATION GUIDELINES
2 2. After review, ship the component to the project for use as a standard. 3. All charges for these shipments shall be identical with the approved component. 4. No component used as a sample will be allowed to be installed on the project. 5. In the event the submissions are disapproved, the components will be returned to the Contractor who shall immediately make a new submission of component meeting the contract requirements. B. Submit shop drawings, for the A/E's acceptance, of a sufficient size to show necessary detail for each component type. Catalog cuts or scale drawings will not be acceptable. C. Shop drawings shall include, but not be limited to: 1. Manufacturer's dimensioned scale drawings showing in complete detail the fabrication of components including finishes, metal thickness, fabrication methods, support methods, method of installation, and other information to show compliance with the Construction Documents. 2. Submit shop drawings and samples of components for approval before fabrication. Details may vary slightly from those shown on Drawings provided the changes to performance or appearance are not altered. 1.5 QUALITY ASSURANCE A. Materials, equipment, appurtenances, and labor provided under this section shall comply with the highest commercial standard and be as specified and as indicated on Drawings. Parts and components not specifically identified or indicated shall be made of materials appropriate for their use or function and resistant to corrosion and thermal and mechanical stress encountered in the normal application and functioning of the components. B. All cast parts, including die-cast members, shall be of uniform quality, free from blow holes, pores, hard spots, shrinkage defects, cracks or other imperfections that affect strength and appearance, or are indicative of inferior metals or alloys. 1. Exterior surfaces that do not receive a finish coat shall be machined, sanded or similarly treated. 2. All finished castings shall be given a minimum of one coat of baked-on clear methacrylate lacquer unless a painted finish is specified. C. Fixtures and components shall be made according to the NEC and bear the UL label. PART 2 PRODUCTS 2.1 EQUIPMENT A. Rigging System: 1. Paint as required under this section shall be the manufacturer's standard finish and color except as noted. 2. Materials shall comply with the ASTM specifications noted in this Sectionr. 3. Materials shall be new, unused and of the latest design. Refurbished materials are not allowed. 4. To establish minimum standards of safety, the following factors shall be used: Project No. SPECIFICATION GUIDELINES
3 a. Cable and fittings: 8.0 Safety Factor. b. Gearmotors: 1.0 Service Factor. c. Cable bending ratio: Sheave is 30 times diameter of cable. d. Tread pressures: 500 lbs. for cast iron, 1000 lbs. for steel. e. Maximum fleet angle: 1-1/2 degrees. f. Steel: 1/5 of yield. g. Bearings: Two times required at full speed for 2000 hrs. 5. Where dimensions and loading capacities have been omitted from this specification, they are to be according to accepted industry standards and the guidelines in this Section. In no way shall the rigging Contractor be relieved of the primary responsibility to provide a safe, fully functional system. 6. The mechanical fabrication and quality of construction shall incorporate best practices for good fit and finish. There shall not be any burrs or sharp edges to cause a hazard nor shall there be any sharp corners accessible to personnel. 7. Moving parts shall have specified tolerances. Sheaves shall run plumb and true and not scrape housings. 8. Equipment shall be built and installed to facilitate future maintenance and replacement. B. Counterweight System: 1. Pipe Battens: Battens shall be 1-1/2" nominal diameter Schedule 40 pipe in lengths as shown on the Drawings. Joints shall be sleeve spliced with 18 inch long sleeves with 9 inches extending into each pipe and held by two 3/8" hex bolts and lock nuts on each side of the joint. a. Manufacturer: J.R. Clancy No R, 40 ft. long or accepted equivalent. 2. Cable fittings and clips shall conform with wire rope manufacturer's recommendations as to size, number and method of installation. a. Clips shall be drop forged "Crosbys" or malleable as required. b. Pressed sleeve fittings shall be "Nicopress". c. Eyes shall be formed over wire rope thimbles of correct sizes. 3. Lead cables, unless otherwise noted, shall be 1/4" diameter 7 x 19 construction, galvanized aircraft cable with a breaking strength of 7000 pounds. a. Do not use damaged or deformed cables. b. Install wire rope rigging to prevent abrasion of the wire rope against any part of the building construction or other equipment. 4. Trim Chains: a. Trim cables shall be 30 inches long with a snap at one end. b. Chain shall be 2/0, passing link with a 500 pound working load. c. Chains shall be installed on the batten end of each lead line. d. Provide one safety bolt, one nut and two flat washers per trim chain. e. Manufacturer: J.R. Clancy No B trim chains or accepted equivalent. Project No. SPECIFICATION GUIDELINES
4 5. Hand Line: a. Hand lines shall be 3/4" first grade Synthetic rope, free of slivers and foreign materials. b. Manufacturer: J.R. Clancy No SGW, - 3/4" sure grip synthetic rope or accepted equivalent. 6. Counterweight: a. Counterweights shall be 13-3/4" long. b. Each piece shall be free from slab and sharp edges. c. Notch two opposite corners to provide finger holds when loading arbors. d. Provide 80 percent of weight 2 inches thick and 20 percent 1 inch thick for each of balancing. e. Manufacturer: J.R. Clancy B&C Counterweights or accepted equivalent. C. Series Head Block: 1. The diameter sheave shall be made of Class 30 grey iron conforming to ASTM A48, shall have a minimum hub diameter of 3-7/8" and be free of holes and casting flaws. 2. The sheave shall be machine faced and turned with equally pitched grooves for the required number of cables and ropes. a. Groove depths shall be sufficient to encompass fully the cables and ropes. b. Grooves shall be sloped sides (8 degree minimum) and comply with rope and cable manufacturer's standards for groove shape and tolerance. c. The sheave shall be fitted with 1 inch Timken tapered roller bearings, properly sized for the required load and speed. d. The 1 inch diameter machined steel shaft shall be keyed to one side plate to prevent rotation. e. Proper adjustment of the bearing shall be accomplished by means of a fine thread, self-locking nut on the opposite end of the shaft. f. Steel side plates with a minimum thickness of 10 gage shall be shaped to fully protect the sheave and eliminate sharp corners and shall be fillet welded to the base angles. g. Base angles shall be fabricated from 2 inch by 1-1/2" by 1/3" angle with the short leg turned in and notched to clear the cables. h. Each head block shall have at least five spacers, three to be placed to prevent cables from escaping from the sheave grooves. i. Each sheave shall run plumb and true without rubbing its side plates when rotated. 3. Furnish each block with two heavy clips that extend the full block width and have an offset to allow for the flange thickness of the mounting beams. Each clip shall be held rigidly in place by two 3/4" diameter bolts and lock nuts. 4. Manufacturers: J.R. Clancy Series 55 or accepted equivalent with cable groove sand rope groove. D. Series Loft Block: 1. Underhung Loft Block: Project No. SPECIFICATION GUIDELINES
5 a. The 8-1/2" diameter sheave shall be made of Class 30 grey iron conforming to ASTM A48, having a minimum hub diameter of inch and be free of holes and casting flaws. b. The sheave shall be machine faced and turned with the require size rope or cable groove. c. Cable groove depths shall be sufficient to encompass the cable fully and shall have sloped sides. d. Conform rope and cable grooves to rope and cable manufacturer's standards for groove shape and tolerance. e. The sheave shall be fitted with 1/2" diameter ball bearings (1/2" diameter Timken tapered roller bearings), properly sized for the required load and speed. f. The 1/2" diameter steel shaft shall have a dutchman to engage the keyhole in the side plate. g. Accomplish proper adjustment of the bearings shall be accomplished by means of a fine thread, self-locking nut on the opposite end of the shaft. h. The block housing shall have two 10 gage side plates rigidly fastened together with at least three 1/4" bolts and three pipe spacers. i. The housing shall also have a drop forged steel center with a 3/4" threaded end fastened to the side plates by two 5/16" bolts. j. Bolts shall have lock nuts. The center shall be threaded to provide for a 4-inch grip adjustment range for the block mounting. A cut in the side plate shall be made with a 1/2" or 3/4" throat to grip the flange of the mounting beam properly. 2. Fasten the block to the steel beam by means of an angle clip mounted on the threaded end of the center with a 3/4" hex nut. This clip, along with the cuts in the side plates, shall properly grip the lower flange of the beam when the nut is tightened. 3. Manufacturer: J.R.Clancy Series 55 or accepted equivalent with a 1/4" groove. E. Series Mule Block: 1. The 8-1/2" diameter sheave shall be made of Class 30 grey iron conforming to ASTM A48 and free of holes and fasting flaws. 2. The sheave shall be machine-faced and turned with the required size cable groove. 3. Cable groove depths shall be sufficient to encompass fully the cable manufacturer's standards for groove shape and tolerance. 4. The sheave shall be fitted with ball bearings (Timken tapered roller bearings) properly sized for the required load, speed and number of grooves. 5. The steel shaft shall have a dutchman to engage the keyhole in the side plate. 6. Proper adjustment of the bearings shall be accomplished by means of a fine thread, self-locking nut on the opposite end of the shaft. 7. Steel side plates with a minimum thickness of 10 gage shall fully protect the sheave and shall be fillet welded to the base. 8. The base shall be fabricated from two C3/4.1 channels. 9. Each block shall have four spacers placed to prevent cables from escaping the sheave grooves. 10. Each block shall run plumb and true without rubbing its side plates when rotated. 11. The block shall be fastened to the building steel with two full width, 3/4" formed clips with 1/2" bolts and lock nuts. 12. Manufacturer: J.R. Clancy Series 12 or accepted equivalent with five cable grooves for 1/4" diameter cable. Project No. SPECIFICATION GUIDELINES
6 PART 3 EXECUTION 3.1 INSTALLATION A. Hang pipes level (+ 1/8") with the finished stage floor and parallel with the upstage proscenium line (+ 1/4") measured at any point at their length. B. Paint or finish shall be durable flat black except materials at or above grid level, headbeam level and loading rail level. C. Furnish plated or painted turnbuckles, clips, tracks, chains and other items of incidental hardware. D. Comply with ASTM standards noted in Article 1.02 of this section. E. Materials used shall be new, unused and of the latest design. Refurbished materials are not acceptable. F. Burrs, sharp edges or sharp corners are not acceptable. G. Install mule blocks, cable rollers, and guides to provide proper alignment, prevent cable and rope abrasion and to maintain specified fleet angles. H. Shop and field welding shall comply with AISC. Spatter, fissures, craters, or other evidence of poor practice are not acceptable. I. Touch-up finishes disturbed during shipping and installation to match the original finish. J. Cable Terminations, Shackles: Use properly sized and installed Nico-press fittings on all cable terminations. Provide shackles on arbors and other similar terminations for ease of disassembly. END OF SECTION Project No. SPECIFICATION GUIDELINES
SECTION STAGE FIRE CURTAIN AND RIGGING
SECTION 11064 STAGE FIRE CURTAIN AND RIGGING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Fire curtain, rigging, and other necessary components to comply with life safety requirements and any other
More informationRequest for Proposal Spaulding High School Stage Rigging Improvements Rochester School District
Request for Proposal Spaulding High School Stage Rigging Improvements Rochester School District The Rochester School District is seeking proposals for improvements to the stage rigging at the Spaulding
More informationNOTE TO SPECIFYING ARCHITECT REGARDING SECTION STAGE EQUIPMENT (INCLUDING DRAPERY REPLACEMENT AND HARDWARE RENOVATION)
NOTE TO SPECIFYING ARCHITECT REGARDING SECTION 11065 STAGE EQUIPMENT (INCLUDING DRAPERY REPLACEMENT AND HARDWARE RENOVATION) This specification includes the following: 1. Renovation of the existing counterweight
More information1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.
PAGE 051200-1 SECTION 051200 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,
More informationSECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS
SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and
More informationItem 442 Metal for Structures
Item 442 Metal for Structures 1. DESCRIPTION 2. MATERIALS Provide structural steel, high-strength bolts, forgings, steel castings, iron castings, wrought iron, steel pipe and tubing, aluminum castings
More informationCITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS
CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS PART 1 - GENERAL 1.01 SUMMARY A. Section Includes furnishing and installing chain-link fabric fence, gate, and appurtenances. 1.02
More informationSECTION STRUCTURAL METAL FRAMING
SECTION 05100 STRUCTURAL METAL FRAMING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Structural steel framing including lintels, shelf angles, bearing plates, anchor bolts and other items as shown on
More informationSECTION METAL STAIRS
SECTION 05 51 00 METAL STAIRS PART 1 GENERAL 1.1 SUMMARY A. Section includes steel stair frame of structural sections, with closed risers; pan to receive concrete fill stair treads and landings; integral
More informationPreassembled steel stairs with concrete-filled treads.
SECTION 055113 - PART 1 - GENERAL 1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this
More information.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC
05 12 00 STRUCTURAL STEEL FRAMING Page 1 of 3 1 General 1.1 SECTION INCLUDES.1 Structural steel framing and support members 1.2 RELATED SECTIONS.1 Section 05 50 00 Metal Fabrications 1.3 REFERENCES.1 American
More informationStudent Services & Classroom Addition
SECTION 055113 - METAL PAN STAIRS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL)
ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL) 686.1. Description. This Item shall govern for designing, fabricating, furnishing and erecting steel traffic signal pole assemblies of the various types
More information1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.
SECTION 05500- METAL FABRICATIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION ALTERNATING TREAD STEEL STAIRS
SECTION 05 51 33.23 - ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 SCOPE OF WORK Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this
More informationSECTION METAL STAIRS
SECTION 05510 METAL STAIRS PART 1 GENERAL 1.01 SECTION INCLUDES A. Stairs with concrete treads. B. Stairs with metal treads. C. Structural steel stair framing and supports. D. Handrails and guards. 1.02
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING
SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationSECTION MISCELLANEOUS METALS
PART 1 GENERAL 1.1 WORK OF THIS SECTION A. Contractor shall provide all labor, materials, equipment and incidentals as shown, specified and required to furnish and install all miscellaneous metal fabrications
More informationDIVISION 5 - STRUCTURAL STEEL AND IRON WORK
DIVISION 5 - STRUCTURAL STEEL AND IRON WORK SECTION 05100 STRUCTURAL METAL FRAMING PART 1.00 GENERAL 1.01 SCOPE OF WORK A. Work Included: 1. 2. Structural steel complete in place. Steel joists complete
More informationSECTION DECORATIVE METAL RAILINGS
SECTION 05 73 00 DECORATIVE METAL RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES A. Vertical Stainless Steel Cable Railing System. B. Horizontal Stainless Steel Cable Railing System. 1.2 RELATED SECTIONS
More informationSECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION
PAGE 055015-1 SECTION 055015 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,
More informationSECTION TIMBER FLOATS
SECTION 06210 PART 1 - GENERAL 1.01 SUMMARY A. This section covers furnishing and installing the timber float framing for the pile guide area, and all other components not specifically mentioned, necessary
More informationITEM 442 METAL FOR STRUCTURES
ITEM 442 METAL FOR STRUCTURES 442.1. Description. This Item shall govern for all structural steel, high strength bolts, forgings, steel castings, iron castings, wrought iron, bronze, steel pipe and tubing,
More informationPRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB ADPH #B
SECTION 05 5213 - PIPE RAILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSECTION 2 DIVISION 05 METALS
SECTION 2 DIVISION 05 METALS DIVISION 5 - METALS Note: This is a guide for Designers only. Contents shall not be used in lieu of specifications as part of the Designer s Contract Documents. GENERAL DESIGN:
More informationAmerican Metal Specialties, Inc.
American Metal Specialties, Inc. www.cablerailings.com (253) 272-9344 (253) 627-3843 Fax PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 05 73 00 STAINLESS STEEL ORNAMENTAL HANDRAILS AND RAILINGS For best
More informationK. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.
DIVISION 05 METALS 05 12 00 STRUCTURAL STEEL FRAMING PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural steel framing members, support members. 1.2 RELATED REQUIREMENTS A. Section 05 50 00 - Metal Fabrications:
More informationFabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.
SECTION - ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 SCOPE OF WORK Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.
More informationKeuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.
SECTION 05 73 16 {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes. PART 1 GENERAL 1.1 SUMMARY A. Section includes cable railing system, with architectural metal
More informationA. American Society for Testing and Materials (ASTM):
SECTION 05500 METAL FABRICATIONS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 03300 - Cast-In-Place Concrete. 2. 03420 - Precast, Prestress Concrete Sections. 3. 04420 - Concrete Unit Masonry. 4.
More informationSTRUCTURAL STEEL FRAMING
SECTION 05 12 00 - STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 SUMMARY A. Section includes 1. Structural steel framing 2. Structural steel framing required for support and framing of rooftop mechanical
More informationSECTION ALTERNATING TREAD STEEL STAIRS
SECTION 05 51 33.23 - ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 SCOPE OF WORK Fabricate and install carbon steel or stainless steel alternating tread stair assemblies in accordance with the requirements
More informationSECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.
PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 13 34 00 FABRICATED ENGINEERED STRUCTURES A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1
More informationITEM 555 CHAIN LINK FENCING
ITEM 555 AFTER MARCH 1, 2012 CHAIN LINK FENCING 555.1 Description. This item shall govern for furnishing the quantities of chain link fencing and gates as shown on the plans, including all posts, bracing
More informationNOTE TO SPECIFYING ARCHITECT REGARDING SECTION CONTOUR CURTAIN AND MOTOR
NOTE TO SPECIFYING ARCHITECT REGARDING SECTION 11074 CONTOUR CURTAIN AND MOTOR 1. This curtain provides a beautiful scalloping Austrian appearance. 2. Contour curtain rises vertically forming a valance
More informationSECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System
SECTION 13096 RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13096-1 RF MODULAR PAN SYSTEM PART 1 GENERAL 1.1
More informationMETALS Commissioning of Metals Structural Steel Framing Steel Studs... 2
~ 05-1 ~ 05 00 00 Metals 05 00 00 METALS... 2 05 08 00 Commissioning of Metals... 2 05 12 00 Structural Steel Framing... 2 05 12 30 Steel Studs... 2 05 45 00 METAL SUPPORT ASSEMBLIES... 2 05 50 00 METAL
More informationSection 906. STRUCTURAL STEEL
906.01 Section 906. STRUCTURAL STEEL 906.01. General Requirements. Finished rolled shapes must be free from imperfections that affect strength and durability in accordance with ASTM A 6. Rolled shapes
More informationAddendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE
SECTION 13 34 00 METAL SHADE STRUCTURE PART 1 - GENERAL 1.01 STRUCTURE TYPE A. Structure shall be free standing rigid frame and gable roof with slopes as indicated. Structure shall also include foundation,
More informationNOTE TO THE SPECIFYING ARCHITECT REGARDING SECTION STAGE EQUIPMENT (TWO PROSCENIUMS)
NOTE TO THE SPECIFYING ARCHITECT REGARDING SECTION 11064 STAGE EQUIPMENT (TWO PROSCENIUMS) Use this specification for platform stages with a proscenium that opens to the cafeteria and another proscenium
More informationSECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.
SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES A. Handrails and guardrails B. Guardrails for hatches and openings. C. Safety barriers. D. Roof edge protection. 1.2 RELATED SECTIONS
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 055113 - METAL PAN STAIRS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationNORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS
PART 1 GENERAL 1.01 SUMMARY Section 15140 PIPE HANGERS, This Section includes the furnishing and subsequent installation of: A. Pipe and equipment hangers, supports, and associated anchors B. Equipment
More informationSECTION ALUMINUM HANDRAIL SYSTEMS
SECTION 05520 ALUMINUM HANDRAIL SYSTEMS PART 1 - GENERAL 1.01 SUMMARY A. Section includes aluminum handrails and railings. B. Related Work: 1. Section 03300 - Cast-in-Place Concrete C. References: 1. American
More informationSECTION 1043 FENCE MATERIAL
SECTION 1043 FENCE MATERIAL 1043.1 Scope. This specification covers the material required in the construction of chainlink fence and woven wire fence. 1043.2 Basis of Acceptance. The basis of acceptance
More information***************************************************************************************************************
09510 ACOUSTICAL CEILINGS SPECIFIER: CSI MasterFormat 2004 number 09 51 00 PART 1 GENERAL 1.1 SUMMARY A. Related Sections: 1. 09200 - Metal Studs, Lath, Suspension Ceilings, Plaster, and Stucco. 2. 09310
More informationSECTION MISCELLANEOUS METALS THIS SECTION TO BE INCLUDED IN SUB BID FOR SECTION MISCELLANEOUS AND ORNAMENTAL IRON
SECTION 055000 THIS SECTION TO BE INCLUDED IN SUB BID FOR SECTION 050001 MISCELLANEOUS AND ORNAMENTAL IRON PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a
More informationSECTION CHAIN LINK FENCES AND GATES (PARK)
SECTION 02821 CHAIN LINK FENCES AND GATES (PARK) PART I GENERAL 1.1 SECTION INCLUDES A. Installation of chain link fences, and gate units provided by single source including erection accessories, fittings,
More informationCONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT
CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT SPECIFICATION EO-1124 REVISION 3 November 2013 EFFECTIVE DATE November 11,
More informationSECTION 2831 ITEM F-162 CHAIN-LINK FENCES
SECTION 2831 ITEM F-162 CHAIN-LINK FENCES PART 1 - GENERAL 1.1 DESCRIPTION. This item shall consist of furnishing and erecting a chain-link fence in accordance with these specifications and the details
More informationMETAL HANDRAILS AND RAILINGS. A. Properly identified manufacturer's literature, including shop and erection drawings before starting work.
SECTION 05520 METAL HANDRAILS AND RAILINGS PART 1 GENERAL 1.01 SUBMITTALS A. Properly identified manufacturer's literature, including shop and erection drawings before starting work. B. Railing Assemblies
More informationSECTION METAL FABRICATIONS
SECTION 05500 METAL FABRICATIONS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 03300 - Cast-In-Place Concrete. 2. 03420 - Precast, Prestress Concrete Sections. 3. 04420 - Concrete Unit Masonry. 4.
More informationMATERIAL SPECIFICATION FOR FRAMES, GRATES, COVERS, AND GRATINGS
ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.PROV 1850 APRIL 2018 (Formerly OPSS 1850, April 2013) Note: The PROV published in April 2018 replaces OPSS 1850 COMMON, April 2013 with no technical content
More information7. New railings for existing buildings shall be designed to match any existing railings unless there is a compelling reason for change.
Division 05. Metals 05 50 00. Metal Fabrications 05 50 00. Roof - Fall Protection The contractor shall provide a horizontal cable lifeline system on steel posts complying with applicable regulatory requirements.
More informationB. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.
SECTION 10 5113 - METAL LOCKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More informationSECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System
SECTION 05 5200 ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System PART 1 GENERAL 1.01 WORK INCLUDED A. Furnish and/or install stainless steel railings and components. 1.02 REFERENCE
More informationB. Shop Drawings: Include plans, elevations, sections, details, and attachments.
SECTION 055119 - METAL GRATING STAIRS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION ORNAMENTAL ALUMINUM RAILING
SECTION 05730 ORNAMENTAL ALUMINUM RAILING PART 1 GENERAL 1.1 SECTION INCLUDES A. Decorative Wire Rope Railing 1.2 RELATED SECTIONS A. Section 03300 Cast-In-Place Concrete: Placement of sleeves cast in
More information2016 CDM Smith All Rights Reserved July 2016 SECTION COMPOSITE STEEL FLOOR DECK
PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 05 36 00 COMPOSITE STEEL FLOOR DECK A. Furnish all labor, materials, equipment and incidentals required and install composite steel floor deck complete as shown
More informationB. Shop Drawings: Include plans, elevations, sections, details, and attachments to other work.
SECTION 055116 - METAL FLOOR PLATE STAIRS PART 1- GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationJAMISON SOUND DOOR SPECIFICATIONS VERTICAL SLIDING SOUND REDUCTION DOOR - STC 53 POWERED OPERATION
JAMISON SOUND DOOR SPECIFICATIONS VERTICAL SLIDING SOUND REDUCTION DOOR - STC 53 POWERED OPERATION PART 1 - GENERAL 1.1 APPLICABLE PUBLICATIONS: The publications listed below form a part of this specification
More information05510: TAPERED STEEL TROLLEY POLES AND ACCESSORIES
PART 1 GENERAL 1.01 DESCRIPTION A. The Vendor shall fabricate, furnish, test and deliver tapered steel trolley poles, including base plates, reinforced hand holes, anchor bolts, nuts and washers, and accessories
More informationSECTION (05300) - STEEL DECKING
SECTION 05 31 00 (05300) - STEEL DECKING PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Roof Deck 2. Composite Floor Deck 3. Noncomposite Form Deck B. Related Sections: 1.02 SUBMITTALS 1. Section
More informationSECTION PIPE AND TUBE RAILINGS PART 1- GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY 1.3 PERFORMANCE REQUIREMENTS
SECTION 055213- PIPE AND TUBE RAILINGS PART 1- GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR LOW-TENSION CABLE BARRIER. OPR:CT 1 of 5 APPR:JAR:DBP: FHWA:APPR:
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR LOW-TENSION CABLE BARRIER OPR:CT 1 of 5 APPR:JAR:DBP:09-07-11 FHWA:APPR:09-07-11 a. Description. This work consists of furnishing and installing
More informationSECTION ORNAMENTAL ALUMINUM RAILING
SECTION 05730 ORNAMENTAL ALUMINUM RAILING PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Pipe Railing 1.2 RELATED SECTIONS A. Section 03300 Cast-In-Place Concrete: Placement of sleeves cast in concrete.
More informationFOR PROJECTS INITIATED AFTER NOVEMBER 1, 2008 REVISION 7 ITEM 516 INSTALLATION OF FLEX BEAM GUARDRAIL
AFTER NOVEMBER 1, 2008 ITEM 516 INSTALLATION OF FLEX BEAM GUARDRAIL 516.1 Description. This item shall govern for furnishing and placing 10 or 12 gauge galvanized flex beam guardrail, complete with timber
More informationSECTION CHAIN LINK FENCES
SECTION 02 44 40 PART 1 - GENERAL 1.1 DESCRIPTION A. Work included: Provide chain link fence system where shown on the Drawings, as specified herein, and as needed for a complete and proper installation.
More informationSECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 [08 33 13] COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Metal Counter
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-08 39 53 (April 2006) -------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-08315 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationCW 3550 Chain Link and Drift Control Fence TABLE OF CONTENTS
January 2014 SPECIFICATION CW 3550 R3 CW 3550 Chain Link and Drift Control Fence TABLE OF CONTENTS 1. GENERAL CONDITIONS... 1 3. DESCRIPTION... 1 5. MATERIALS... 1 5.1 Drift Control Fence... 1 5.1.1 Approved
More informationBSR E XX DRAFT Rig/ r3. BSR E1.4-2, Entertainment Technology Statically Suspended Rigging Systems.
BSR E1.4-2, Entertainment Technology Statically Suspended Rigging Systems Table of Contents 1 GENERAL... 2 1.1 Scope... 2 1.2 Purpose... 2 1.3 Application... 2 1.4 Alternative materials, design and methods
More informationSECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system.
PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Fusion welded and rackable ornamental steel picket fence system. B. Related sections: 1. Section 03310 Concrete Work for post support. 2. Section 09960
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-08 56 63 (April 2006) --------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-11191 (September 1999) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationSERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651
SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651 PART 1 GENERAL 1.1 DESCRIPTION A. Work Included: 1. Furnish all labor and materials to complete the fabrication of detention windows
More informationNorthpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017
SECTION 055213 - PIPE AND TUBE RAILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationInsulating Cellular Concrete Steel Joists Painting. A. America Society for Testing and Materials (ASTM):
SECTION 05120 STRUCTURAL STEEL PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 03342 - Insulating Cellular Concrete. 2. 05210 - Steel Joists. 3. 09900 - Painting. 1.02 REFERENCES A. America Society
More informationThe Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.
SECTION 05 31 13 STEEL FLOOR DECKING PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including General and Supplementary Conditions and Division 01 - Specification
More information1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures.
BID OPPORTUNITY NO. 253-2011 PAGE 1 OF 7 PART 1 GENERAL 1.1 REFERENCES.1 American Society of Mechanical Engineers (ASME).1 ASME B31.1, Power Piping, B31.3 Process Piping, B31.9 Building Services Piping..2
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT
SECTION 220529 - HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The General Conditions, Special Conditions and Division 1 through Division 22 as set forth in
More informationSECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION
SECTION 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 - GENERAL 1.1 SUMMARY A. This section supplements all sections in this division, including pipe, fittings, valves, and connections for sprinkler
More informationSECTION SUSPENDED MAINTENANCE ANCHORAGE SYSTEM
SECTION 112423 SUSPENDED MAINTENANCE ANCHORAGE SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Suspended Access Anchorage Systems: 1. System design and certification. 2. Fall protection roof anchors. 3.
More informationPRODUCT SPECIFICATIONS PULTRUDED GRATING AND TREADS SECTION PART 1 GENERAL
PRODUCT SPECIFICATIONS PULTRUDED GRATING AND TREADS SECTION 06600 PART 1 GENERAL 1.1 Related Documents A. Drawings and general provisions of Contract, including General and Supplementary Conditions and
More informationProduct Guide Specification
ALGRIP Manufactured by April 2017 104 North Maple Avenue P.O. Box 646 Leola, Pennsylvania 17540 Toll Free 800-345-8170 Fax 717-656-2041 Website www.algrip.com / www.rosstechnology.com E-mail sales@rosstechnology.com
More informationDIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.
PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe and equipment support systems. B. Inserts. 1.02 RELATED SECTIONS A. Section 15890 - Ductwork Supports. 1.03 DEFINITIONS A. Supports: Attachments, hangers,
More informationSUPPORT AND ANCHORS SECTION 15090
SUPPORT AND ANCHORS SECTION 15090 PART 1 GENERAL 1.1 DESCRIPTION OF WORK A. Work included in this Section: Materials, equipment, fabrication, installation and tests in conformity with applicable codes
More informationSECTION STRUCTURAL STEEL FRAMING
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 05 12 00 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // ---// if not applicable to project. Also delete any other item or paragraph
More informationSECTION METAL FLOOR PLATE STAIRS
SECTION 05513 - METAL FLOOR PLATE STAIRS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationCONCRETE STEPS, HANDRAILS, AND SAFETY RAIL
SUDAS Standard Specifications Division 9 - Site Work and Landscaping Section 9080 - Concrete Steps, Handrails, and Safety Rail CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL PART - GENERAL.0 SECTION INCLUDES
More informationSECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT
SECTION 230548 - VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary
More information1. Manufacturer's product lines of railings assembled from standard components.
SECTION 057300- DECORATIVE METAL RAILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementmy Conditions and Division 01 Specification
More informationSECTION COLD-FORMED METAL TRUSSES
SECTION 054400 COLD-FORMED METAL TRUSSES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationPIPE AND TUBE RAILINGS. Evansville Christian High School RELATED DOCUMENTS 1.1
SECTION 055213 - PART 1 - GENERAL 1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this
More informationSECTION CHAIN LINK FENCING
SECTION 02835 - CHAIN LINK FENCING 1.0 GENERAL 1.1 Furnish and install chain link fencing complete in place with gates and accessories as specified herein and as shown on the Contract Drawings. 1.2 Reference
More informationSECTION ROLLER GATES
GENERAL SUMMARY A. The Contractor shall provide all labor, materials, equipment, and incidentals required to furnish and install roller gates, complete and operational with all necessary accessories as
More informationSECTION FLAGPOLES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 10 75 00 SPEC WRITER NOTE: 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph
More informationSECTION NON-STRUCTURAL METAL FRAMING
SECTION 09 22 16 PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories
More informationSECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)
SECTION 13125 ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More information