FRANCE. Draft, approved for Phase I 14 September 2008
|
|
- Cory Murphy
- 6 years ago
- Views:
Transcription
1 Monitoring and evaluation of energy certification in practice with focus on central European states ANNEX I Country Reviews Draft, approved for Phase I 14 September 2008 Imprint Federal Ministry of Transport, Building and Urban Affairs (BMVBS) Invalidenstraße Berlin The Federal Office for Building and Regional Planning (BBR) Deichmanns Aue Bonn Carried out by ARGE Energieausweise Mitteleuropa Dr. Roland Kopetzky Ingo Therburg Prof. Dr. Fritz Schmidt National information from Rhônalpénergie-Environnement, France Emmanuel Jeanjean BBR-Online-Publikation Nr.
2 Energy certification in European countries 2 CONTENT 1. NATIONAL HIGHLIGHTS LEGAL FRAMEWORK National distinctions of legislation History of energy related requirements Overview on EPBD implementation Time schedule of implementation METHODOLOGIES New buildings Existing buildings Energy certificates New building Existing buildings Public building National software REQUIREMENTS New buildings Renewables, CHP, district heating/cooling Existing buildings Definition major renovation Energy certificates ENERGY PERFORMANCE CERTIFICATES General description New buildings Existing buildings Public buildings Definition of public buildings Additional aspects On site visit INDEPENDENT EXPERTS Training Accreditation Quality assurance Organisational aspects Number of experts available Transboundary certification DATA COLLECTION Availability and organisation of national data collection Access and use of the collected data EXPERIENCES, EVALUATION, COSTS General availability of experiences with EPBD implementation Existing studies, surveys and evaluations Number of energy performance certificates Effort and costs of energy performance assessment Time and costs Subsidies ACCEPTANCE OF THE ENERGY PERFORMANCE CERTIFICATION PLANS FOR FUTURE DEVELOPMENT Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
3 Energy certification in European countries 3 ANNEX 1... OVERVIEW RELEVANT LEGISLATION Regarding EPC : Regarding EPBD implementation ANNEX 2 EXAMPLE ENERGY CERTIFICATES General description Energy Performance Certificate s models in France Energy certificate building and accommodation for RENT with individual heating Differences for residential buildings for sale : Existing non residential buildings for sale or new non residential buildings: The specificity of EPC for public building certificates : Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
4 Energy certification in European countries 4 1. National Highlights Methodology Requirements Legislation No difference is made between the metered energy consumption and the calculated energy demand in the energy certificates. For building built before 1948 not methodology is defined, the energy certificate is always made from metered energy consumption. The reference values for the energy certification are the same for all building types (primary energy < 50 kwh/m²a class A and > 450 kwh/m²a G ), except: For non residential buildings two more classes are added at the end of the scale (H /I) Public buildings are divided into three buildings categories (permanent occupation, non permanent occupation and others). The range of reference values is from kwh/m²a (permanent), kwh/m²a (non-permanent), kwh/m²a (others). Different law texts and decrees describe the energy certificates calculation mode according the different situation of delivering : sold, rented or public building The indoor air temperature in cooled buildings is restricted to a minimum temperature of 26 C (ref. law) 2. Legal Framework 2.1. National distinctions of legislation Law : the first reference to energy certificates appears in the Program Law for Energy (Loi no du 13 juillet 2005) Decree (Décrets) : 2 decrees explain the principle of the energy certificates Orders (Arrêtés) : most of the text on energy certificates are Guidelines, they develop the calculation, dates of application 2.2. History of energy related requirements France introduced the first thermal regulation for new buildings in 1974 (Thermal Regulation RT). Maximum values for the heat losses (G-value) were determined. This regulation is revised more or less every 5 years. The last one (2005 Thermal regulation, RT 2005) went into effect on 1st September With the last revision, the requirements were changed from the G-values to the maximum consumption (C value). In the past, no requirements for existing buildings existed. Renovations could be carried out even on a worse level than it was before. Due to the EPBD implementation, in May 2007 a new regulation for existing buildings was introduced Overview on EPBD implementation In France, there is a series of legislative texts and regulations. The thermal regulations for existing and new buildings are now listed in the official legal texts. Official tools for their implementation are available (calculation methods for thermal regulation, EPC tools ). Local government bodies of Equipment are in charge with the control of the regulation application. A testing procedure is carried out in this respect (control of several new buildings taken at random). In order to develop future energy performance in new buildings constructions, Tax credits are anticipated. For example, social housing companies can qualify for property tax exoneration if their building reaches a certain performance. For all owners, exemptions can be granted to increase the occupation of the ground in the case of a respect of a performance level (< 50 kwh/m²a). And exemptions can be granted for all property owners in order to increase land use when a certain level of performance is met Time schedule of implementation Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
5 Energy certification in European countries 5 In the last two years France introduced a lot of new laws and the implemented of the energy certification was carried out very quickly. Since beginning of 2008 for all types of buildings, the issuance of EPC/DEC are mandatory. One exception non residential buildings for rent. Requirements on new and existing buildings are (will be) in force Residential building Non Residential building New building Existing building For sale For rent Public building Issuance of energy performance certificates is mandatory since Residential building Non Residential building New building Existing building For sale For rent Public building Methodologies Article 3: Member States shall apply a methodology, at national or regional level, of calculation of the energy performance of buildings 3.1. New buildings RT 2005 (thermal regulation) is applied according to a calculation methodology based on hourly rate. The consumption of reference building consumption is calculated Cref, the project consumption (primary energy) (Cep) must be small than the reference : Cep < Cref. There are also minimum requirements for building components (U-values, lighting, heating system, ventilation system). Order : arrêté du 24 mai 2006 relatif aux caractéristiques thermiques des bâtiments nouveaux et des parties nouvelles de bâtiments 3.2. Existing buildings The introduction of rules for existing buildings is quite recent: decree of 3 may Beforehand there was no energy regulation specifically applicable to existing buildings or buildings under renovation. Two types of regulation is applied : - for big buildings (net area > 1000m2 and refurbishment works amount is bigger than 25% of the value of the building) : special study is required, same approach as thermal regulation for new buildings, - for all others building refurbishment works, values have to be respected for each part of the building (roof insulation, glazing, boiler performance ). Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
6 Energy certification in European countries Energy certificates New building Always asset rating has to be used. Order : Arrêté du 21 septembre 2007 relatif au diagnostic de performance énergétique pour les bâtiments neufs en France métropolitaine This text only says for new building the EPC is calculated from the data contained in thermal study done for the building design Existing buildings Two methodologies for energy performance calculation are applied: Asset and operational rating. In principal both methodologies can be used, exepts the following situation: If the building is constructed before 1948, it can be assumed, that no information regarding building construction is available. Under these conditions U-Values can only be assessed. To avoid the assessment, this buildings has to be calculated on the base on metered energy (operational rating) If only parts of the energy consumption are available and the other parts has to be delivered through tenants. Due to data protection reasons, this buildings has to be calculated on the base of the energy demand calculation (asset rating) See synthesis of the methodologies used in annexe Public building Energy certificates for public buildings are always based on metered energy consumption (operational rating). The mean consumption of the last 3 years is used in this case National software A national software is available for asset rating for existing buildings : 3cl-DPE. Methodologies can be used as long as they respect the regulation specifying the content of the methods (Order of 15th September 2006 relating to Methods and Procedures) 2 other methods have been approved by the Order of 9th November 2006: Comfie-DPE, DEL6-DPE. For new buildings, data providing from Th-CE calculation methodology can be used directly. Comfie-DPE, DEL6-DPE and Th-CE are time based on a hourly rate. When using an asset calculation methodology, the main methodology used is simplified : 3CL DPE. This method has been developed under the responsibility of the ministry. With a detailed description of the building: orientation, position, floors surface, walls, windows, isolation level (thickness and building material properties), nature of equipment (heating, domestic hot water, cooling), type of ventilation default values are used to find out the linked loss of energy and thus to agree on the building primary energy need based on heat or cooling production. Also climate zone and altitude are taken into accounts. 4. Requirements Article 4: Member States shall take the necessary measures to ensure that minimum energy performance requirements for buildings are set, based on the methodology referred to in Article New buildings Article 5: Member States shall take the necessary measures to ensure that new buildings meet the minimum energy performance require-ments referred to in Article 4. Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
7 Energy certification in European countries 7 RT 2005 (thermal regulation) is applied according to a calculation methodology based on hourly rate. RT 2005 is a logical evolution of RT 2000, the EU directive did not introduce anything from this point of view Renewables, CHP, district heating/cooling Article 5: For new buildings with a total useful floor area over m2, Member States shall ensure that the technical, environmental and economic feasibility of alternative systems such as: decentralised energy supply systems based on renewable energy, CHP, district or block heating or cooling, if available, heat pumps, under certain conditions, is considered and is taken into account before construction starts. Since the the 1rst January 2008 for any new building larger than 1000m2 a feasibility study must be realised. This study must contain the economic and technical feasibility of different energy solutions fort he building feeding. The aim if this measure is to encourage renewables and efficient systems. The owner can choose the energy sources he wants guided by this study considering energetic, economic and environmental criteria. Reference texts : decree n March 2007 and 18 December 2007 order Existing buildings Article 6: Member States shall take the necessary measures to ensure that when buildings with a total useful floor area over m2 undergo major renovation, their energy performance is upgraded in order to meet minimum requirements in so far as this is technically, functionally and economically feasible. Since the 1rst April 2008, for renovated building larger than 1000m2 with a renovation works cost higher than 25% of the building value, a feasibility study must be realised. This study must contain the economic and technical feasibility of different energy solutions fort he building feeding. The aim if this measure is to encourage renewables and efficient systems. The owner can choose the energy sources he wants guided by this study considering energetic, economic and environmental criteria. Reference texts : decree n March 2007 and 18 December 2007 order Definition major renovation Major renovation : this is the case when the cost of the renovation works are higher than 25% of the value of the building. Building costs are decided by national order (ex : 20 December 2007, cost for residential : 1287 /m2 ; for non residential : 1100 /m2) Energy certificates New building Residential building Non Residential building Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
8 Energy certification in European countries 8 Existing building Public building 5. Energy performance certificates Article 7/1: Member States shall ensure that, when buildings are constructed, sold or rented out, an energy performance certificate is made available to the owner or by the owner to the prospective buyer or tenant, as the case might be General description The same certificate is used for asset and operational rating. The reference values are also the same for asset and operational rating. In any case the EPC must contain : - building identification, net area - energy sources used and description of the main thermic, energetic and geometric characteristics, a list of the main equipments - by use the annual mean of final energy consumed, if the segmentation is not possible per use it can be done par energy source - by use the annual mean of primary energy consumed, if the segmentation is not possible per use it can be done par energy source - annual costs of energy - representation on two different scales of the total primary energy consumed and the total CO2 emission linked - the part of renewable energy produced on site - specific recommendations for management of the building and his equipments, and recommendations for renovation works leading to a reduction of energy consumption 5.2. New buildings For new buildings asset rating is always used. For new buildings the certificate is calculated from the thermal study of the building integrating (surrequirements) 5.3. Existing buildings EPC are carried out with 2 methods, it depends on the context. The main characteristic is the age of the buildings: if their construction is prior to 1948 then the metered energy consumption (operational rating) is always authorised. The use of calculation methods is compulsory in the following cases: Individual residential houses Flats using central heating Whole Residential building New building For existing tertiary buildings, we always use the metered energy consumption (operational rating) 5.4. Public buildings Energy certificates for public buildings are always based on metered energy consumption (operational rating). Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
9 Energy certification in European countries 9 For public buildings, 3 types of buildings have been defined with different classification threshold : - buildings with intermittent occupation (Education, administration ) - buildings with permanent occupation (hospitals, police station ) - buildings with irregular occupation (Sport centre, theatre, concert hall ) Definition of public buildings Article 7/3 Member States shall take measures to ensure that for buildings with a total useful floor area over m2 occupied by public authorities and by institutions providing public services to a large number of persons and therefore frequently visited by these persons an energy certificate, not older than 10 years, is placed in a prominent place clearly visible to the public. Public buildings submitted to the EPC are buildings : - owned or rented by a public authority, - open to the public, with a minimum capacity of 300 persons, - bigger than 1000m Additional aspects On site visit The site visit is compulsory. However, in the case of residential buildings with central heating, it is possible to visit one flat only and deliver certificates for all the other flats. 6. Independent experts Article 10 Member States shall ensure that the certification of buildings, the drafting of the accompanying recommendations and the inspection of boilers and air-conditioning systems are carried out in an independent manner by qualified and/or accredited experts, whether operating as sole traders or employed by public or private enterprise bodies 6.1. Training Training is not compulsory but it is recommended. Quite a few companies who didn t benefit from training are now promoting them. On the contrary, certification is compulsory and is structured by the Order of 16th October 2006 defining certification criteria of consultants skills delivering the EPC and defining accreditation criteria of certification companies. Training sessions normally take 3 days and cover Theoretical and practical aspects Accreditation The certification is a theoretical and practical exam looking to validate the EPC issuers skills. These skills are: Theoretical: - the typology of constructions and constructive systems, construction products, technical equipments, construction materials and their thermal properties, building thermal characteristics, possibilities for energy improvements, legal and regulations texts on the subject, implementation of renewable energies, some knowledge in legal aspects, building technical and legal terminology. Practical : The candidate can carry out the EPC using an adapted method, can explain the results, can evaluate a building consumption via at least one method. And the candidate is able to propose adapted recommendations, knows how to write reports in French. The certification takes one day. Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
10 Energy certification in European countries Quality assurance The EPC issuer s skills are controlled the second year via an exam comprising the analysis of 10 EPC carried out Organisational aspects Real estate certificates providers were already working on asbestos, lead, on measurement There are the same companies providing energy performance certificates. Thus, their activity has quite developed. Several thermal consulting companies are also able to deliver certificates on whole public buildings or complex buildings. The French Committee of Accreditation (COFRAC) delivers official approval to certification companies to assess and certify EPC providers. COFRAC existed previously, and was commissioned by the government to deliver these accreditations. Certification companies also existed previously and have developed their activity in this context Number of experts available In 2006: 6000 professionals in real estate certifications, in activity Transboundary certification Not available. It seems quite difficult considering the specificities of the application of the European directive in each country or in European regions. 7. Data Collection 7.1. Availability and organisation of national data collection Data collection is planned for public buildings, but is not operational yet. The National Environment and Energy Management Agency (ADEME) should be in charge of this collection Access and use of the collected data 8. Experiences, evaluation, costs 8.1. General availability of experiences with EPBD implementation Not available 8.2. Not available Existing studies, surveys and evaluations 8.3. Number of energy performance certificates In 2008 we can estimate the number of certificates issued between 2.6 and 3 millions Effort and costs of energy performance assessment Time and costs 2 to 3 hours are required. The price is very flexible. Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
11 Energy certification in European countries 11 The average price for flats with individual heating and for individual houses is 200 euros. It depends on the method used, on the surface and the need to visit the site or not as extrapolation is possible for a flat in a residential building and central heating (see above). It can goes up to 500 euros for a large building Subsidies There are no subsidies for EPC issuing, as it is compulsory. However, if it is a voluntary approach by coowners for example, they can have a subsidy to have a complete diagnosis including a performance energy certificate. 9. Acceptance of the energy performance certification Topic of phase 3 (July September 2008) 10. Plans for future development Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
12 Energy certification in European countries 12 Annex 1 Overview relevant legislation 1. Regarding EPC : The general order of the legislation is : Law : the first reference to energy certificates appears in the Program Law for Energy (Loi no du 13 juillet 2005) Decree (Décrets) : 2 decrees explain the principle of the energy certificates Orders (Arrêtés) : most of the text on energy certificates are Guidelines, they develop the calculation, dates of application Decree of 14th Sept 2006 relating to the energy performance certificate and the condition of the gas installation in several buildings (defining the EPC) Order of 15th Sept 2006 relating to the energy performance certificate for existing buildings for sale (clarifying the EPC of buildings for sales Housing and Tertiary sectors) Order of 15th Sept 2006 relating to methods and procedures applicable to the EPC for existing buildings for sale in France Order of 16th October 2006 defining certification criteria of consultants skills delivering the EPC and defining accreditation criteria of certification companies Order of 9th November 2006 giving approval for several calculation methods used for the EPC Order of 3rd May 2007 relating to the EPC for existing buildings proposed for accommodations to let Order of 21st September 2007 relating to EPC for new buildings Order of 7th December 2007 relating to the EPC display in public buildings Order of 18th December 2007 modifying the order dated 15th Sept 2006 relating to EPC for existing buildings for sale (and précising the coefficients CO2/kWh of district heating and cooling networks of France). 2. Regarding EPBD implementation Decree of 19 March 2006 relating to feasibility studies for energy supply, thermal characteristics and energy performance of existing buildings and display of energy performance certificates. Energy supply study for new buildings: 1st January 2008 Energy supply study for renovated buildings over 1000m2 (with major refurbishment):1st April 2008 Obligation of energy performance for renovated buildings over 1000m2 (with major refurbishment): 1st April 2008 Obligation of energy performance for removed equipments or new equipment installed in existing buildings: 1st November 2007 Limiting the use of cooling when the temperature is below 26 C: 1st July 2007 Display of the energy performance certificate in public buildings: 2nd January 2008 Decree of 3 may 2007 relating to thermal characteristic and energy performance of existing buildings. Decree of 18 December 2007 relating to feasibility studies for energy supply for new buildings, for new parts of buildings and for several existing renovated buildings Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
13 Energy certification in European countries 13 Annex 2 Example energy certificates 1. General description The example certificate should lock as follows : 1. Table/overview on your different types of certificates Synthesis of the methodologies used : INDIVIDUAL HOUSES COLLECTIVE BUILDINGS FOR PRINCIPAL DWELLINGS FOR SALE THE OWNER OF THE PROPOSED SALE IS NOT THE OWNER OF THE ENTIRE BUILDING. OR THE OWNER CARRIES OUT A CO-OWNERSHIP GLOBALLY PROPOSED FOR SALE Asset rating Allowed Allowed Operational rating Built before Built after January 1948 January 1948 Collective heating system Not allowed except if an estimation on the entire building is made Individual heating system Built before January 1948 Built after January 1948 Built before January 1948 Built after January 1948 Allowed Allowed Allowed Allowed Allowed Not Allowed Allowed Allowed Not Allowed Allowed Not allowed except in the case of a collective heating system FOR RENT Asset rating Not Allowed Allowed Operational rating INDIVIDUAL HOUSES Built before Built after January 1948 January 1948 Collective heating system Not allowed except if an estimation on the entire building is made COLLECTIVE BUILDINGS FOR PRINCIPAL DWELLINGS THE EPC RELIES ON THE BUILDING CONSUMPTION Individual heating system Built before January 1948 Built after January 1948 THE EPC RELIES ON THE BUILDING ENTIRE CONSUMPTION ALREADY DETERMINATED BY A PREVIOUS EPC Built before January 1948 Built after January 1948 Allowed Allowed Not Allowed Allowed Allowed Not Allowed Allowed Allowed Not Allowed Allowed Not Allowed 2. Description of the differences of you different types of certificates 3. Example of one energy certificate (translated) 4. Only if the differences between the certificates are very significant (for ex. EPC/DEC) than add further certificates Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
14 Energy certification in European countries Energy Performance Certificate s models in France In France, a lot of different certificates have been defined according to different conditions: Type of building, residential, tertiary or public buildings Event linked to the delivery: sold, rented, new or displaying in public buildings. The presentations of all the certificates contain some slight specificities, but are based on the same principle: The model is 4 pages Page 1 : data regarding the building (address, owner, surface...), energy consumption and costs, two scales one for primary energy and one CO2. Page 2 : description of the building elements and heating or cooling equipments, and explanation on the certificate content, Page 3 : recommendations regarding energy management (more or less always the same in every kind of certificates), Page 4 : recommendations regarding works advised (insulation, change of boiler ). Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
15 Energy certification in European countries Energy certificate building and accommodation for RENT with individual heating Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
16 Energy certification in European countries 16 Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
17 Energy certification in European countries 17 Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
18 Energy certification in European countries 18 Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
19 Energy certification in European countries Differences for residential buildings for sale : Page 4 : works recommendations are detailed (new consumption after works, investment for works, pay-back time...) in case of houses or apartments with individual heating system. In case of collective heating system the recommendation are less detailed. In the case of residential buildings for rent, the certificate is the same, but the recommendations are not so detailed as they are for sale. Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
20 Energy certification in European countries Existing non residential buildings for sale or new non residential buildings: The main difference is the number of level on the certificate (9 classes : A to I) instead of 7 A to H. Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
21 Energy certification in European countries 21 In the case of new buildings the first page is detailed by energy uses. Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
22 Energy certification in European countries The specificity of EPC for public building certificates : Two presentation are possible for the first page : Energy consumption by end-uses (if possible) or by type of energy. The classes values are different regarding the type of buildings : 1 Permanent occupation 2 Non permanent occupation 3 Other types Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
23 Energy certification in European countries 23 Annex I Country Review _ doc BBR-Online-Publication Nr. 23/2007
I Prophets energy services
CIBSE LOW CARBON CONSULTANTS REGISTER SESSION 2 EPBD OVERVIEW I Prophets energy services 03012013 Energy Performance Buildings Directive Transposition National Calculation Method Performance Standards
More informationImpact, Compliance and Control of EPBD Legislation in Germany
ASIEPI - Assessment and improvement of the EPBD Impact (for new buildings and building renovation) Impact, Compliance and Control of EPBD Legislation in Germany Hans Erhorn, Heike Erhorn-Kluttig Fraunhofer
More informationTitle of the measure: General description. FRA16 Energy Efficiency Certificates
Title of the measure: FRA16 Energy Efficiency Certificates General description The law n 2005-781 ( programme fixant les orientations de la politique énergétique ) adopted the 13th of July 2005 introduces
More informationBuildings: a huge potential for energy savings in France
Buildings: a huge potential for energy savings in France France s Climate Plan Seminar 20th November 2017 Stéfan Le Dû Sustainable Development Councilor Embassy of France in Japan Ministry of Ecological
More informationBULGARIAN LEGISLATION IN THE FIELD OF ENERGY EFFICIENCY HEAT RETENTION AND ENERGY CERTIFICATION OF NEW AND EXISTING BUILDINGS
BULGARIAN LEGISLATION IN THE FIELD OF ENERGY EFFICIENCY HEAT RETENTION AND ENERGY CERTIFICATION OF NEW AND EXISTING BUILDINGS GOVERNMENTAL POLICY FOR HARMONIZATION of the technical rules and regulations
More informationPilot Project Efficient Homes
Felicitas Kraus, Head of Division International Cooperation Pilot Project Efficient Homes Paris, 02.02.2011 Ownership structure of dena. dena Federal Republic of Germany 50 % KfW Bankengruppe 26 % Represented
More information2. Current status of Implementation of the EPBD I. ENERGY PERFORMANCE REQUIREMENTS
Implementation of the EPBD in Lithuania STATUS IN DECEMBER 2014 1. Introduction The Energy Performance of Buildings Directive (Directive 2010/31/EU EPBD) sets out numerous requirements including the certification
More informationSTATUS IN DECEMBER Current status of Implementation of the EPBD I. ENERGY PERFORMANCE REQUIREMENTS
Implementation of the EPBD in Portugal STATUS IN DECEMBER 2014 1. Introduction The national implementation of the Energy Performance of Buildings Directive (Directive 2010/31/EU EPBD) started in 2007,
More informationUpdate of the Residential and Non-residential Building Stock Renovation Strategy, Slovak Republic
Update of the Residential and Non-residential Building Stock Renovation Strategy, Slovak Republic Bratislava, 24 April 2017 Contents Introduction 3 1. Background and current approach to the renovation
More informationEnergy savings certificates in France Selection of calculation sheets. IEA-DSM Task XXI: Standardisation of Energy Savings Calculation
Energy savings certificates in France Selection of calculation sheets IEA-DSM Task XXI: Standardisation of Energy Savings Calculation March 2010 Household sector Insulation building envelope Internal wall
More informationModule 15. Country Specific Legislation
Module 15 Country Specific Legislation Module 15 Country Specific Legislation On completion of this module learners will be able to: List the main pieces of legislation and standards which affect the energy
More informationThe challenges, dynamics and activities in the building sector and its energy demand in France
The challenges, dynamics and activities in the building sector and its energy demand in France D2.1 of WP2 from Entranze Project Written by: Bruno Lapillonne, Carine Sebi and Nicolas Mairet Enerdata, with
More informationISO INTERNATIONAL STANDARD. Energy performance of buildings Calculation of energy use for space heating and cooling
INTERNATIONAL STANDARD ISO 13790 Second edition 2008-03-01 Energy performance of buildings Calculation of energy use for space heating and cooling Performance énergétique des bâtiments Calcul des besoins
More informationBifluid Geothermal System New Generation
Bifluid Geothermal System New Generation The Geothermal Energy - from the Greek roots geo, meaning earth, and thermos, meaning heat - ie the thermal energy stored in the underground of our planet, and
More informationA households panel for energy efficiency works : a contribution for policy assessement
IPEEC conference, Paris June 2010 A households panel for energy efficiency works : a contribution for policy assessement Dr Didier BOSSEBOEUF (ADEME) Chantal Derkenne (ADEME) Contents Introduction The
More informationAct. on the Promotion of Renewable Energies in the Heat Sector. (Erneuerbare-Energien-Wärmegesetz EEWärmeG)*) of 2008
Act on the Promotion of Renewable Energies in the Heat Sector (Erneuerbare-Energien-Wärmegesetz EEWärmeG)*) of 2008 The Bundestag has adopted the following Act: Contents Part 1 General provisions Article
More informationThe case of France: Energy efficiency policies in the building sector. Title
The case of France: Energy efficiency policies in the building sector Title Near zero energy buildings, lessons learned from overseas experience and Energy Renovation Plan Philippe Guillard, Deputy Director
More informationOverview of national applications of the Nearly Zero- Energy Building (NZEB) definition
Hans Erhorn Heike Erhorn-Kluttig Overview of national applications of the Nearly Zero- Energy Building (NZEB) definition Detailed report April 2015 www.epbd-ca.eu Overv iew of national applications of
More informationEuropean Green Capital Award Frankfurt am Main s application Environmental indicator 12 Energy performance
European Green Capital Award Frankfurt am Main s application Environmental indicator 12 Energy performance Question 1 (max. 1,000 words) Present details of the original and/or most recent Action Plan,
More informationThe challenges, dynamics and activities in the building sector and its energy demand in Italy
The challenges, dynamics and activities in the building sector and its energy demand in Italy D2.1 of WP2 from Entranze Project Written by: Paolo Zangheri, Lorenzo Pagliano end use Efficiency Research
More informationnzeb Germany - Strategy to improve energy efficiency in the German building sector and the leading role of public buildings Dr.-Ing.
BBR Bonn 2011 nzeb Germany - Strategy to improve energy efficiency in the German building sector and the leading role of public buildings Dr.-Ing. Olaf Böttcher - Commissioner for Energy in Federal Buildings
More informationComplying with the Minimum Energy Efficiency Standards (MEES)
Complying with the Minimum Energy Efficiency Standards (MEES) Advantages of using DSM software to calculate the EPC Rating Introduction The Minimum Energy Efficiency Standards (MEES) for commercially rented
More informationRIEEB Regional Impact with Energy Efficient Buildings Introducing the EPBD Results of RIEEB. 24. October 2012 Leipzig
RIEEB Regional Impact with Energy Efficient Buildings Introducing the EPBD Results of RIEEB 24. October 2012 Leipzig The EPBD 24. October 2012 The European Performance of Buildings Directive (EPBD) This
More informationMEMO 27 June District heating and combined heat and power in China
MEMO 27 June 2013 File no. Ref. Ole Odgaard Page 1 District heating and combined heat and power in China District heating has expanded rapidly in Northern China since the beginning of the 1990 s. Residential
More informationThe full length version of this article is availbale at the journal website
The full length version of this article is availbale at the journal website http://www.rehva.eu/en/rehva-european-hvac-journal Energy saving potential by retrofitting residential buildings in Europe Cristina
More informationEnergy Performance Certificate
Energy Performance Certificate 8, Ludlow Road Dwelling type: Semi-detached house GUILDFORD Date of assessment: 0 November 010 GU 7NR Date of certificate: 0 November 010 Reference number: 8897-956-349-1906-4903
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland FLAT 0/1, 27 COVENTRY DRIVE, GLASGOW, G31 3JG Dwelling type: Ground-floor flat Date of assessment: 10 September 2015
More informationABSTRACT: VENTILATION The European Commission, Energy Performance of Buildings Directive, and its Ventilation Implications. Eric Curd.
ABSTRACT: VENTILATION. 2006. The European Commission, Energy Performance of Buildings Directive, and its Ventilation Implications. Eric Curd. Consulting Engineer. UK. This paper considers the ventilation
More informationCzech Republic: Energy Efficienc. Petr Holub 15 October 2009, Tokyo
Czech Republic: Concrete measures Energy Efficienc Renewable Ener Petr Holub 15 October 2009, Tokyo Potential of EE in Czech Republic: which way do we choose 1 400 000 2 000 000 1 200 000 1 800 000 1 600
More informationDeliverable 3.a (Combining former deliverables 3.1; 3.2; 3.5)
City Supporting partner Kortrijk, Belgium VITO Map showing local heating and cooling demand and supply Map indicating the heat demand for space heating per address (highest segment: 16.6 to 1837 MWh/year/address)
More informationEnergy Certification of Buildings, 2009
Austria Belgium Energy Certification Providing Act (2006), approved by Parliament in 24/05/2006, which obligates the vendors and landlords to provide energy certificates for buildings when put up for sale
More informationNATIONAL POLICY FOR ENERGY EFFICIENCY AND RENEWABLE ENERGY SOURCES
REPUBLIC OF BULGARIA MINISTRY OF ECONOMY, ENERGY AND TOURISM NATIONAL POLICY FOR ENERGY EFFICIENCY AND RENEWABLE ENERGY SOURCES Aleksandrina Dimitrova Head of Department Renewable Energy Sources Energy
More informationPolicies and measures on energy saving in the domestic sector in the Netherlands
Policies and measures on energy saving in the domestic sector in the Netherlands Cadence Appendix L drs. M. van Brummelen August 2006 Cadence E 4068 ECOFYS, Postbus 8408, NL-3503 RK Utrecht, Nederland,
More informationBuilding Regulations Part L 2013 For England. Ant Wilson Director/AECOM Fellow Building Engineering AECOM
Building Regulations Part L 2013 For England Ant Wilson Director/AECOM Fellow Building Engineering AECOM 1 st May 2014 2 Building Byelaws Thermal Insulation 3 Bringing in Part L 2002 Working With DETR
More informationGENERAL DIRECTORATE OF ENVIRONMENT, CONSTRUCTION, ENERGY AND ΜINERAL INSPECTORATE. P a g e 1 NORTHERN AND SOUTHERN HELLENIC DIRECTORATE
GENERAL DIRECTORATE OF ENVIRONMENT, CONSTRUCTION, ENERGY AND ΜINERAL INSPECTORATE P a g e 1 NORTHERN AND SOUTHERN HELLENIC DIRECTORATE P a g e 2 Table of Contents Energy Performance of Buildings Certificates
More informationPredicted Energy Assessments and Energy Performance Certificates for new homes Explained
Predicted Energy Assessments and Energy Performance Certificates for new homes Explained A Predicted Energy Assessment and an Energy Performance Certificate are issued on new build dwellings and are part
More informationEPBD implementation in
EPBD implementation in STATUS AT THE END OF 2012 1. Introduction In Germany, the transposition of the recast Energy Performance of Buildings Directive (EPBD) is mainly processed via an amendment of the
More informationEnergy Performance Certificate (EPC)
Energy Performance Certificate (EPC) SMITHY COTTAGE, SCOTTISH BORDERS, KELSO, TD5 8LZ Dwelling type: Detached house Date of assessment: 08 May 2014 Date of certificate: 22 May 2014 Total floor area: 103
More informationEnergy Intelligent Education
International Conference on Energy Efficient Renovation in Residential Building Sector 28-29 June 2010 Energy Intelligent Education By Elsebeth Terkelsen Arch. MAA, Head of Department Aarhus School of
More information(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)
Energy Performance Certificate 12, Andrew Close HALIFAX HX3 9RT Dwelling type: Mid-terrace house Date of assessment: 29 November 2011 Date of certificate: 29 November 2011 Reference number: 8190-0719-7329-6126-5993
More informationD12. Energy and LCC calculations interim report
Executive Agency for Competitiveness and Innovation (EACI) Life-Cycle-Costs in the Planning Process. Constructing Energy Efficient Buildings taking running costs into account Grant Agreement D12 Document
More informationQuantification of carbon emissions from the UK building stock
Quantification of carbon emissions from the UK building stock Paul Davidson Director, Sustainable Energy November 2009 Overview Contribution of buildings to UK carbon emissions Modelling energy use in
More informationAuthors. Towards 2020 OVERVIEW AND OUTCOMES. 1. General information. 2. Objectives
Towards 2020 OVERVIEW AND OUTCOMES 1. General information To support EU Member States (MS) in the task of implementing Directive 2002/91/EC on the Energy Performance of Buildings (EPBD), the Concerted
More informationCOUNTRY REPORT: FRANCE
COUNTRY REPORT: FRANCE Prepared by: CSTB Version 02 Date: 03/09/2010 Address: BP 209 F-06909 Sophia-Antipolis Cedex Tel. : 33 4 93 95 67 00 Fax : 33 4 93 95 64 31 E-mail: dominique.caccavelli@cstb.fr QAiST
More informationEuropean Energy Policy and Standardization Buildings and Building Components
European Energy Policy and Standardization Buildings and Building Components J.J. BLOEM DG JRC http://ec.europa.eu/dgs/jrc Serving society Stimulating innovation Supporting legislation TOWARDS 2030 framework
More informationSUMMER THERMAL COMFORT IN TYPICAL FRENCH RESIDENTIAL BUILDINGS: IMPACT ASSESSMENT OF BUILDING ENVELOPE INSULATION ENHANCEMENT
13th Conference of International Building Simulation Association, Chambéry, France, August 26-28 SUMMER THERMAL COMFORT IN TYPICAL FRENCH RESIDENTIAL BUILDINGS: IMPACT ASSESSMENT OF BUILDING ENVELOPE INSULATION
More informationEnergy Efficiency in Germany Status & Perspectives
Energy Efficiency in Germany Status & Perspectives October 7, 2013 in Bridgeport (USA) Dr. Hartmut Grewe energiewaechter GmbH by order of Energy Efficiency Export Initiative sponsored by the Federal Ministry
More informationEnergy Efficiency in Buildings in the EU and in Japan 13 December 2013
Energy Efficiency in Buildings in the EU and in Japan 13 December 2013 Benefits of Energy Efficiency in Buildings François-Xavier Lienhart Saint-Gobain MAG-Isover When we think about Energy, we think about
More informationMitsubishi Electric Guide to Minimum Energy Efficiency Standards for Non-dwellings. Information Guide 60
Mitsubishi Electric Guide to Minimum Energy Efficiency Standards for Non-dwellings Information Guide 60 Information Guide 60 Mitsubishi Electric Guide to Minimum Energy Efficiency Standards for Non-dwellings
More informationTowards an Energy Efficient European Building Stock
An RICS Status Report on the Implementation of Directive 2002/91 on the Energy (EPBD) in the EU Member States rics.org/eu Towards an Energy Efficient European Building Stock An RICS Status Report on the
More informationKarin Fant (Energimyndigheten, Sweden), Horst Schettler- Köhler (BBR, Germany), Solenn le Guen (DGEC, France) Prepared by CA Working Group
Reporting framework of equivalence according to the Directive 2010/31/EU on Energy Performance of Buildings Article 14 Paragraph 4 & Article 15 Paragraph 4 Prepared by CA Working Group Date 12 June 2014
More informationEnergy Performance Certificate
Energy Performance Certificate Apartment 32 Britannic Park 15 Yew Tree Road Moseley BIRMINGHAM B13 Dwelling type: Mid-floor flat Date of assessment: 28 March 2012 Date of certificate: 28 March 2012 Reference
More informationEnergy Performance Certificate (EPC)
Energy Performance Certificate (EPC) You can use this document to: 1F1, 17 BRYSON ROAD, EDINBURGH, EH11 1ED Dwelling type: Mid-floor flat Date of assessment: 21 October 2013 Date of certificate: 24 October
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland FLAT 0/1, 7 DUDLEY DRIVE, GLASGOW, G12 9SE Dwelling type: Ground-floor flat Date of assessment: 07 November 2016 Date
More informationEnergy Performance Certificate
Energy Performance Certificate 9 Alpha House Dwelling type: Top-floor flat Napier Road Date of assessment: 04 October 010 CROWTHORNE Date of certificate: 04 October 010 RG45 7AU Reference number: 896-5448-109-6806-003
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland FLAT 2, 7 NEW ORCHARDFIELD, EDINBURGH, EH6 5ES Dwelling type: Ground-floor flat Date of assessment: 10 November 2017
More information(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)
Energy Performance Certificate 2, Brackenfield Road BIRMINGHAM B44 9BH Dwelling type: Top-floor flat Date of assessment: 22 November 2011 Date of certificate: 22 November 2011 Reference number: 9394-2832-6293-9529-0565
More informationThermal insulation of buildings and cooling demand
411 Thermal insulation of buildings and cooling demand C. Hamans Rockwool International S.A.,The Netherlands ABSTRACT Thermal insulation in the warm climate can reduce the energy demand for cooling in
More informationMarjana Šijanec Zavrl, Erik Potočar,
Practical Implementation of the Cost- Optimal Regulation for establishing nation Minimum Requirements in Slovenia Marjana Šijanec Zavrl, Marta Skubic, Andraž Rakušček, Henrik Gjerkeš, Building and Civil
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 31 ARTILLERY PARK, HADDINGTON, EH41 3PZ Dwelling type: Semi-detached bungalow Date of assessment: 18 September 2017
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 83 CARRICK KNOWE AVENUE, EDINBURGH, EH12 7DE Dwelling type: Top-floor flat Date of assessment: 06 December 2017 Date
More informationEnergy Efficiency. best in class
Page 1 The impact of Building Automation on Energy Efficiency Siemens with DESIGO and Synco best in class Energy is a major issue for the European Union Primary energy use in Europe Dependency Without
More informationEnergy Performance Certificate (EPC)
Energy Performance Certificate (EPC) You can use this document to: FLAT 16, 11 RUSSELL GARDENS, EDINBURGH, EH12 5PG Dwelling type: Top-floor flat Date of assessment: 08 August 2014 Date of certificate:
More informationNearly zero energy building renovation, the EU-GUGLE project Javier Llorente Yoldi
Nearly zero energy building renovation, the EU-GUGLE project Javier Llorente Yoldi jllorente@cener.com In a nutshell European cities serving as Green Urban Gate towards Leadership in sustainable Energy
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 5 ST SUNNIVA STREET, LERWICK, SHETLAND, ZE1 0HL Dwelling type: End-terrace house Date of assessment: 26 July 2017 Date
More informationImp ementation Case:
ZEMedS: Implementation Implementation Case: ITIS Merloni, Fabriano, Italy General data 3 Name of the School Type of school ITIS MERLONI High School High School Number of students Owner 398 public Location
More informationEnergy Performance Certificate (EPC)
Energy Performance Certificate (EPC) You can use this document to: 13H CATTERMILLS, CROFTAMIE, GLASGOW, G63 0BB Dwelling type: Top-floor flat Date of assessment: 28 November 2014 Date of certificate: 01
More informationPartnership between energy companies and installers How White Certificates can finance energy efficiency for building renovation
Partnership between energy companies and installers How White Certificates can finance energy efficiency for building renovation Financing energy efficiency in private housing Opportunities from energy
More informationEnergy Performance Certificate
Energy Performance Certificate Flat 6 Rugby Court Rugby Road WORTHING West Sussex BN11 4PY Dwelling type: Mid-floor flat Date of assessment: 04 March 2011 Date of certificate: 04 March 2011 Reference number:
More informationEnergy Performance of Buildings Directive and nearly-zero Energy Buildings
Energy Performance of Buildings Directive and nearly-zero Energy Buildings J.J. BLOEM DG JRC http://ec.europa.eu/dgs/jrc Serving society Stimulating innovation Supporting legislation TOWARDS 2030 Framework
More informationItalian Pilot Project
ACER Italian Pilot Project TAVOLI DI LAVORO Efficienza Energetica Edifici Es Collaboration with ACER Tavoli di Lavoro ACER Italian Pilot Project In Collaboration with ACER (Social housing company) - Monitoring
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 12 STATION SQUARE, ST MARYS, ORKNEY, KW17 2SE Dwelling type: Semi-detached bungalow Date of assessment: 08 August 2017
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 14 HIGH STREET, KIRKWALL, KW15 1AZ Dwelling type: Mid-terrace house Date of assessment: 05 June 2017 Date of certificate:
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 1F1, 41 MARCHMONT CRESCENT, EDINBURGH, EH9 1HF Dwelling type: Mid-floor flat Date of assessment: 26 June 2015 Date
More informationThe use of economic instruments to renovate Europe
IEA workshop The use of economic instruments to renovate Europe Bogdan ATANASIU Buildings Performance Institute Europe Bogdan.atanasiu@bpie.eu Summary: Economic instruments to renovate Europe - Main barriers
More informationBuilding & Ductwork Airtightness Standards
Building & Ductwork Airtightness Standards Version 1.02, August 2013 Standard Reference Technical Body Title ICS (International Classification for Standards) Scope Door and Windows EN 12207:1999 Windows
More informationImplementation of buildings energy efficiency : Feedback from a local perspective. A french experience PARIS CLIMATE AGENCY
AVEC VOUS, POUR ÉCONOMISER L ÉNERGIE AU QUOTIDIEN Buildings Energy Efficiency Policies The bumpy road to effective implementation Implementation of buildings energy efficiency : Feedback from a local perspective
More informationThe impact of Building Automation on Energy Efficiency. Siemens with DESIGO and Synco best in class. Siemens AG, plc, All Rights Reserved
The impact of Building Automation on Energy Efficiency Siemens with DESIGO and Synco best in class Page 1 Siemens AG, plc, 2010 2009 All Rights Reserved Energy is a major issue for the European Union Primary
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 47 ELMWOOD AVENUE, INVERNESS, IV2 6HE Dwelling type: Detached house Date of assessment: 29 January 2018 Date of certificate:
More informationEnergy Performance Certificate
Energy Performance Certificate 19 Grosvenor Gardens NEWCASTLE UPON TYNE NE2 1HQ Dwelling type: Top-floor flat Date of assessment: 21 October 2011 Date of certificate: 21 October 2011 Reference number:
More informationOICE/EFCA CONFERENCE 2010 Build-Up and Overview of European Initiatives on Energy Efficiency and Sustainable Construction
OICE/EFCA CONFERENCE 2010 Build-Up and Overview of European Initiatives on Energy Efficiency and Sustainable Construction Roger Hitchin BRE Summary EU Sustainable Development Strategy A brief overview
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 29 HORDALAND, KIRKWALL, KW15 1UN Dwelling type: End-terrace bungalow Date of assessment: 10 January 2018 Date of certificate:
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 2 COURTHILL FARM COTTAGES, KELSO, TD5 7RU Dwelling type: Semi-detached house Date of assessment: 02 March 2017 Date
More informationEnergy Performance Certificate
Energy Performance Certificate, Gladridge Close Dwelling type: Ground-floor flat Earley Date of assessment: 19 January 011 READING Date of certificate: 19 January 011 RG6 7DL Reference number: 8549-609-8750-1351-99
More informationAsset Energy Calculator Guidance
Asset Energy Calculator Guidance Introduction This section has been produced to give BREEAM In-Use assessors further guidance on the workings of the asset energy calculator so it is clear how any improvements
More informationImp ementation Case:
ZEMedS: Implementation Implementation Case: IPCT Bonifazi, Recanati, Italy General data 3 Name of the School Type of school IPCT Recanati High School High School Number of students Owner 277 public Location
More informationMeeting the energy audit requirement of the Energy Efficiency Directive
Meeting the energy audit requirement of the Energy Efficiency Directive & introducing other headline elements of the implementing legislation including CHP provisions Enda Gallagher and Errol Close, Department
More informationconservation of fuel and power
The conservation of fuel and power Approved document Conservation of fuel and power in new dwellings 2013 edition for use in England* main changes in the 2013 edition This approved document, Approved Document
More information(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)
Energy Performance Certificate 18, Coleridge Road Maltby ROTHERHAM S66 7LT Dwelling type: Mid-terrace house Date of assessment: 20 January 2012 Date of certificate: 01 February 2012 Reference number: 0598-2026-6252-9452-2960
More informationVentilation in residential buildings: A comparison of different calculation methodologies in the context of the EPBD
S. Wössner et al, D: Ventilation in residential buildings: A comparison of different calculation... 1 Ventilation in residential buildings: A comparison of different calculation methodologies in the context
More informationQUALICHECK STUDY AUSTRIA - ASSESSMENT OF EPC INPUT DATA BASED ON RECALCULATION AND ON-SITE VALIDATION
Authors Susanne Geissler, Peter Wallisch (OEGNB) Lukas Maul (University of Applied Sciences Technikum Wien) fact sheet #12 2016.6 Technology All technologies Aspect Status on the ground Country Austria
More informationPositive measures to. Winter-Proof Your Home. and reduce energy costs
Positive measures to Winter-Proof Your Home and reduce energy costs With temperatures plummeting and energy prices soaring - it s time to Winter-Proof Your Home At Kingspan Retrofit we know that your home
More information(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)
Energy Performance Certificate Decleigh Mill Lane BRIGG DN20 8NA Dwelling type: Detached house Date of assessment: 22 August 2011 Date of certificate: 22 August 2011 Reference number: 2228-0096-6268-8899-4900
More informationAvailable online at ScienceDirect. Energy Procedia 78 (2015 )
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 78 (215 ) 1859 1864 6th International Building Physics Conference, IBPC 215 An evaluation of distributed solar thermal "net metering"
More informationRES - Status Quo, Potential and Prospects Vasileios Tsolakidis, CRES
RES - Status Quo, Potential and Prospects Vasileios Tsolakidis, CRES 20 June 2017, Thessaloniki Greek energy sector 2 Source: Eurostat (2017) RES targets Directive 2009/28/EC Gross final energy consumption
More informationPANORAMA OF DISTRICT HEATING (and current Market) FRANCE: Heat fund 2016
PANORAMA OF DISTRICT HEATING (and current Market) FRANCE: Heat fund 2016 Rencontre Franco- Danoise 13-14 septembre 2016 Michel Cairey-Remonnay (Coord. Fonds Chaleur) ADEME Activity areas AQA air quality
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 6 PIPERSQUOY TERRACE, KIRKWALL, KW15 1EL Dwelling type: Mid-terrace bungalow Date of assessment: 21 November 2017 Date
More informationPassive Houses Worlswide: International Developments
Passive Houses Worlswide: International Developments Henk Kaan, ECN Energy Research Centre of the Netherlands, P.O. Box 1, 1755 ZG Petten, The Netherlands, Isolda Strom, DHV Building and Industry, P.O.
More informationBuilding Energy Code:
BSA meeting Building Energy Code: Overview in MA Ian Finlayson Deputy Director, Energy Efficiency Division National Model Code Refresher Updates every 3 years open stakeholder process Approx 30% EE savings
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland FLAT 1, 5 O'CONNELL STREET, HAWICK, TD9 9HT Dwelling type: Ground-floor flat Date of assessment: 10 October 2014 Date
More information