INSTALLATION INSTRUCTIONS FOR FLUE KIT
|
|
- Sydney Carson
- 5 years ago
- Views:
Transcription
1 INSTLLTION INSTRUCTIONS FOR FLUE KIT VERTICL FLUE TERMINL SSEMBLY Ø 80/5 MM FOR GS CONDENSING PPLINCES: GREENSTR CDi COMBI/SYSTEM/REGULR, GREENSTR Si, GREENSTR i JUNIOR/i SYSTEM, GREENSTR Ri 3x x 4x O UK/IE GB (009/09)
2 CONTENTS CONTENTS Symbols and safety precautions Explanation of symbols Safety precautions installation regulations Use General Standard specifications Examples of installation of vertical flue with roof exit Straight flue without bends Straight flue with two 45 -bends Straight flue with two 90 -bends Mounting Notes on fitting Roof-exit clearances Flat roof Inclined roof Fitting the flue daptor Vertical Flue Terminal ssembly Clamp Fire stop plate (009/09)
3 SYMBOLS ND SFETY PRECUTIONS SYMBOLS ND SFETY PRECUTIONS. EXPLNTION OF SYMBOLS WRNING SYMBOLS Signal words indicate the seriousness of the hazard in terms of the consequences of not following the safety instructions. NOTICE indicates possible damage to property or equipment, but where there is no risk of injury. CUTION indicates possible injury. WRNING indicates possible severe injury. DNGER indicates possible risk to life. IMPORTNT INFORMTION DDITIONL SYMBOLS Symbol B Safety instructions in this document are framed and identified by a warning triangle which is printed on a grey background. Electrical hazards are identified by a lightning symbol surrounded by a warning triangle. Notes contain important information in cases where there is no risk of personal injury or material losses and are identified by the symbol shown on the left. They are bordered by horizontal lines above and below the text. Meaning a list entry Tab. a step in an action sequence a reference to a related part in the document or to other related documents a list entry (second level). SFETY PRECUTIONS IF YOU SMELL GS B Do not smoke or strike matches. B Do not turn electrical switches ON or OFF. B Put out naked flames. B Open doors and windows. B Keep people away from the affected area. B Turn off the control valve at the meter. B Call your gas company. -or- B Call emergency number IF YOU SMELL FUMES FROM THE PPLINCE B Switch off the appliance. B Open windows and doors. B Inform your heating engineer. INSTLLTION INSTRUCTIONS Please read these instructions carefully before starting installation. If you are in any doubt contact Worcester Technical Support. These installation instructions must be read in conjunction with the appliance manual. Please leave these instructions with the user or at the gas meter after installation or servicing. Distance learning and training courses are available from Worcester, Bosch Group. BENCHMRK Please leave these instructions with the completed Benchmark Checklist (or a certificate confirming compliance with IS 83, EIRE only) with the owner after installation or servicing. The Benchmark Checklist can be found in the back two pages of the appliance installation manual (009/09) 3
4 INSTLLTION REGULTIONS FITTING ND MODIFICTIONS Fitting the flue system to the appliance must be carried out by a GS SFE registered, competent person in accordance with these installation instructions and the current Gas Safety Regulations (Installation and Use). Flue systems must not be modified in any way other than as described in the fitting instructions. ny misuse or unauthorised modifications to the appliance, flue or associated components and systems will invalidate the warranty. The manufacturer accepts no liability arising from any such actions, excluding statutory rights. B Position the flue terminal in such a way so that combustion products do not enter the building or cause a nuisance. B Position the flue in such a way so the flue does not cause an obstruction. B Ensure the flue terminal is not obstructed and combustion products can discharge without hindrance. B Fit the flue according to the regulations and standards. SERVICING dvise the user to have the system serviced annually by a GS SFE registered, competent person using approved spares, to help maintain the economy, safety and reliability of the appliance. The service engineer must complete the Service Record on the Benchmark Checklist after each service. INSTLLTION REGULTIONS Current Gas Safety Regulations (Installation and Use): Failure to install flue systems correctly could lead to prosecution. ll flue systems and associated components must be installed by a GS SFE registered, competent person in accordance with the following regulations. Relevant regulations: Gas Safety Regulations 998 (Installation and Use) Building Regulations Building Regulations (Northern Ireland) Building Standards (Scotland) (Consolidation) IS 83 (Eire) IGE Gas Installation in Timber Frame Buildings ny other local requirement The relevant British Standards to be followed, include: BS5440: Flues and ventilation for gas appliances of rated heating not exceeding 70 kw (net): Flues BS5440: Flues and ventilation for gas appliances of rated heating not exceeding 70 kw (net): ir Supply BS7698 Installation of gas fired appliances of rated input up to 70 kw (net) If no specific instruction is given, refer to the British Standard Codes of Practice (009/09)
5 USE 3 USE 3. GENERL The installation of a gas condensing appliance must be in accordance with the relevant British Standard, the relevant Building Regulations and any local rules. The surface temperature of the flue is below 85 C. Therefore the distance from a combustible building material is kept to a minimum of 5 mm. 3. STNDRD SPECIFICTIONS Ø 6 Ø FLUEING TO C 33 : The flue gas accessory is part of CE approval when discharging flue gas according to C 33. For this reason, only the original flue gas accessories may be used. Ø Ø 59 3x 3 ll illustration dimensions are shown in mm unless stated otherwise Ø 5 x 6 4x 7 Fig. Ø O Vertical Flue Terminal ssembly daptor Ø 80/5 mm 3 Screws 4 Securing screw 5 Clamp 6 Fire stop plate 7 Screws and wall plugs (009/09) 5
6 EXMPLES OF INSTLLTION OF VERTICL FLUE WITH ROOF EXIT 4 EXMPLES OF INSTLLTION OF VERTICL FLUE WITH ROOF EXIT 4. STRIGHT FLUE WITHOUT BENDS ppliances GREENSTR 4i/8i JUNIOR GREENSTR 5Si/30Si GREENSTR i/5i/8i/4i SYSTEM GREENSTR Ri/5 Ri/8 Ri/4 Ri GREENSTR 7CDi GREENSTR 30CDi GREENSTR 37CDi GREENSTR 40CDi REGULR GREENSTR 4CDi GREENSTR 30CDi SYSTEM/REGULR Tab. L max 5.0 m 3.0 m 6.0 m 8.5 m 4. STRIGHT FLUE WITH TWO 45 -BENDS ppliances GREENSTR 4i/8i JUNIOR GREENSTR 5Si/30Si GREENSTR i/5i/8i/4i SYSTEM GREENSTR Ri/5 Ri/8 Ri/4 Ri GREENSTR 7CDi GREENSTR 30CDi GREENSTR 37CDi GREENSTR 40CDi REGULR GREENSTR 4CDi GREENSTR 30CDi SYSTEM/REGULR Tab. 3 L max 3.0 m.0 m 4.0 m 6.5 m 645 Ø 35 Ø Ø 35 L Ø 5 L Fig O B 75 B Vertical Flue Terminal ssembly daptor Ø 80/5 mm Extension Fig. 3 Vertical Flue Terminal ssembly daptor Ø 80/5 mm Extension B 45 bend O (009/09)
7 EXMPLES OF INSTLLTION OF VERTICL FLUE WITH ROOF EXIT 4.3 STRIGHT FLUE WITH TWO 90 -BENDS L max GREENSTR 4i/8i JUNIOR GREENSTR 5Si/30Si GREENSTR i/5i/8i/4i SYSTEM GREENSTR Ri/5 Ri/8 Ri/4 Ri.0 m 645 Ø 35 GREENSTR 7CDi GREENSTR 30CDi GREENSTR 37CDi GREENSTR 40CDi REGULR GREENSTR 4CDi GREENSTR 30CDi SYSTEM/REGULR 9.0 m.0 m 4.5 m C 365 Ø 5 L Tab. 4 C 645 Ø O Ø 5 Fig. 5 C L 645 Ø C Ø Fig O L Key to Fig. 4, 5 and 6: Vertical Flue Terminal ssembly daptor Ø 80/5 mm Extension C 90 bend C C O Fig (009/09) 7
8 MOUNTING 5 MOUNTING 5. NOTES ON FITTING The vertical flue ( ) can be extended at any point between the adaptor [] and the flue terminal assembly [] using the flue kits 45 bend, 90 bend or extension. For flue pipe maximum and equivalent lengths with the usage of bends refer to the installation instructions with the appliance. Horizontal flue sections should be fitted with an incline of 3 (= 5, %, 5, cm per meter) in the direction of flow of the flue gases. 5.. INCLINED ROOF B Tab mm, in areas with frequent heavy snow falls 500 mm 60, in areas with frequent heavy snow falls ROOF-EXIT CLERNCES 5.. FLT ROOF Combustible building material Non-combustible building material X 500 mm 500 mm Tab. 5 B X J Fig O Fig (009/09)
9 MOUNTING 5.3 FITTING THE FLUE 5.3. DPTOR B Grease the flue-pipe seal of the adaptor with solventfree grease (e.g. Vaseline). B Unscrew the screws around the flue connection on the air box. B Connect rest of flue ( , 45 bend, 90 bend or extension ) to adaptor [] and secure with screw [4]. CO Fig O B lign adaptor so that the flue testing points are facing forwards. O O B Fix adaptor [] in place using screws [3] of Fig. daptor 4 Securing screw O Fig. 0 daptor 3 Screw (009/09) 9
10 MOUNTING 5.3. VERTICL FLUE TERMINL SSEMBLY B Determine the length L V of the double pipe. B Fit pipes together by twisting and pushing home as far as possible secure with screw. L V Fig. Vertical Flue Terminal ssembly O B Cut off the double pipe at a right angle, deburr the cut edges and clean. B Lightly grease the seals on the sleeves with a solventfree grease (e. g. Vaseline) O Fig. 3 Vertical Flue Terminal ssembly (009/09)
11 MOUNTING CLMP If necessary B Fix the vertical flue terminal assembly with the clamp FIRE STOP PLTE If necessary B Mount the fire stop plate O Fig. 4 Vertical Flue Terminal ssembly 5 Clamp O Fig. 5 Vertical Flue Terminal ssembly 6 Fire stop plate (009/09)
12 CONTCT INFORMTION WORCESTER, BOSCH GROUP: TECHNICL: SERVICE: SPRES: LITERTURE: TRINING: SLES: WEBSITE: worcester-bosch.co.uk Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR4 9SW. Tel Fax Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd. worcester-bosch.co.uk
FLUE KIT INSTALLATION MANUAL
FLUE KIT INSTALLATION MANUAL 7 76 9 55 ROOM SEALED TELESCOPIC FLUE 7 76 9 086 PLUME MANAGEMENT SYSTEM GREENSTAR 60/00 HORIZONTAL FLUE FOR USE WITH WORCESTER GREENSTAR GAS-FIRED APPLIANCES: Greenstar FS
More informationGREENSTAR OILFIT FLUE RS
FLUE KIT INSTALLATION INSTRUCTIONS 7 76 90 06 ROOM SEALED 80/mm STANDARD TELESCOPIC FLUE 7 76 90 06 ROOM SEALED 80/mm SHORT TELESCOPIC FLUE 7 76 90 09 80mm PLUME MANAGEMENT SYSTEM 7 76 90 0 ROOM SEALED
More informationInstallation Instructions
Installation Instructions Flue Gas System Basic Kit GA-K - Chimney Flue Gas System for GB125 Oil Condensing Boiler For trained and certified installers Please read carefully prior to installation. 6 720
More informationBALCONY FLUE OUTLET KIT
BLCONY FLUE OUTLET KIT LOGIC Combi LOGIC + Combi LOGIC Heat LOGIC + Heat LOGIC System LOGIC + System LOGIC Code Combi i-mini When replacing any part on this appliance, use only spare parts that you can
More informationAir flue duct for use with ecotec boilers
For the installer Flue installation instructions Air flue duct for use with ecotec boilers Concentric System Ø 80/5 (Galvanized steel air duct/plastic flue duct) GB Contents Notes on the documentation
More informationLOGIC FLUE & ACCESSORIES GUIDE.
& ACCESSORIES GUIDE. COMBI C COMBI ESP1 + COMBI C SYSTEM S + SYSTEM S HEAT H + HEAT H CODE COMBI ESP1 WWW.IDEALBOILERS.COM This manual is for guidance only and must be read in conjunction with the Installation
More informationSpecification for Flue Options
Specification f Flue Options NOTTINGHM ROD, BELPER, DERBSHIRE DE6 JT TELEPHONE 0870 606 FCSIMILE (077) 8069 www.saunier-duval.co.uk TECHNICL HELPLINE 077 8800 IN RRNT HELPLINE 077 9 C.E. British Gas Service
More informationLOGIC FLUE & ACCESSORIES GUIDE.
& ACCESSORIES GUIDE. COMBI C COMBI ESP1 + COMBI C SYSTEM S + SYSTEM S HEAT H + HEAT H CODE COMBI ESP1 WWW.IDEALBOILERS.COM This manual is for guidance only and must be read in conjunction with the Installation
More informationUL, KUL, WG-KUL, ARK, ARK-1
Installation manual GB/en Non-return dampers Types UL, KUL, WG-KUL, ARK, ARK-1 TROX GmbH Heinrich-Trox-Platz 47504 Neukirchen-Vluyn Germany Phone: +49 (0) 2845 2020 Fax: +49 (0) 2845 202265 E-mail: trox@trox.de
More informationHeat only boiler Potterton Promax HE Plus
Heat only boiler Potterton Promax HE Plus You can rely on Potterton The ultimate in reliability and service With Potterton on your side, you can be sure that you re offering your customers the ultimate
More informationInstallation & User Manual
Desktop UHF Radio Paging System Installation & User Manual Scope Communications UK Ltd, Quantum House, Steamer Quay, Totnes, Devon TQ9 5AL Tel: +44 1803 860700 Fax: +44 1803 863716 Email: sales@scope-uk.com
More informationSlim-Line Heat only boiler. Potterton Promax HE Plus (SL)
Slim-Line Heat only boiler Potterton Promax HE Plus (SL) You can rely on Potterton The ultimate in reliability and service With Potterton on your side, you can be sure that you re offering your customers
More informationInstallation Instructions. PolyPro Double-Wall Flex Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro Flex
Installation Instructions PolyPro Double-Wall Flex Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro Flex A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES
More informationHELIOSTAR 252, 218 HORIZONTAL, FREE INSTALLATION
HELIOSTAR 252, 218 HORIZONTAL, FREE INSTALLATION INSTALLATION INSTRUCTIONS ENERGY AND SANITARY SYSTEMS Installation requirements General requirements The free-standing installation set is to be used for
More informationRinnai Infinity XR26/HD200 Internal Flueing
Flueing Options and Rinnai Flue Kits Available Rinnai have developed two flueing kits to make installation of Rinnai Infinity XR26i/XR26ia and HD200i Internal units as easy as possible. Use the kit options
More informationRediflow Concrete Gas Flue System
Rediflow Concrete Gas Flue System Rediflow Concrete Gas Flue System Rediflow the complete gas flue block system Red Bank s range of Rediflow pre-cast concrete gas flue block system manufactured to BS EN
More informationSorrento Stone Surrounds
Sorrento Stone Surrounds For use with Riva 800, Riva 1050 & Studio 22 Installation and Maintenance Instructions For Use in Great Britain and Republic of Ireland (GB & IE) This product is suitable for use
More informationInstallation instructions
Installation instructions Holetherm Double-walled flue gas discharge system (DW) 2016 All information in this release is subject to misprints. No liability is accepted for the consequences of misprints.
More informationExceptionally strong and flexible Proven durability and long life 20 year warranty CE marked and HETAS approved
Exceptionally strong and flexible Proven durability and long life 20 year warranty CE marked and HETAS approved Chimneys Liners Renewables The trusted name for Multifuel flexible liners for over 30 years
More informationHELIOSTAR 252, 218 VERTICAL, FREE INSTALLATION
HELIOSTAR 252, 218 VERTICAL, FREE INSTALLATION INSTRUCTION MANUAL ENERGY AND SANITARY SYSTEMS Installation requirements General requirements The free-standing installation set is to be used or installing
More informationIndustrial flue gas probes. Instruction manual
Industrial flue gas probes Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 4 2.1. About this document... 4 2.2. Ensure safety... 4 2.3. Protecting the environment...
More informationTested to BS EN and BS EN 1443
Tested to BS EN 1856-2 and BS EN 1443 Introduction Page 2 Midtherm Flue Systems Limited is an independent British manufacturing company producing a wide range of flue and chimney products, along with associated
More informationMETALLIC CHIMNEY LINER SYSTEMS
SINGLE WLL CONSTRUCTION RIGID CHIMNEY LINER METLLIC CHIMNEY LINER SYSTEMS TECHNICL DT ND PRTS SELECTION Models CBI and CBH Commerical/Industrial Stainless Steel Single Wall Construction CONTENTS SECTION...
More informationPE57 HOLT 2 DOUBLE SWING OWNER S MANUAL
PE57 HOLT 2 DOUBLE SWING OWNER S MANUAL - Not suitable for children under 36 months due to small parts, cords and the design of the product. - For children ages 3-12 years and must be used under adult
More informationConergy SolarFamulus II
Conergy SolarFamulus II Installation manual www.conergy.com Table of Contents Table of Contents SolarFamulus II for universal use on flat roofs 1 Introduction 1 1.1 Short description 1 1.2 Intended use
More informationTI/131 TECHNICAL ADVICE ON THE SITING OF CLASS 1 TYPE OIL STORAGE INSTALLATIONS FOR SINGLE FAMILY DWELLINGS
TI/131 TECHNICAL ADVICE ON THE SITING OF CLASS 1 TYPE OIL STORAGE INSTALLATIONS FOR SINGLE FAMILY DWELLINGS Cover Price 10 (ex. VAT and p&p) (Please note this information sheet is available from the OFTEC
More informationSI T T FST
SI 440-600-700-700T-780-780T-900-1100 Freestanding TAPER TOP Open Fire - Wood Burner Installation Instructions Note: FLUE SYSTEMS Casing. Flue System may require to be Doubled Lined to Comply. Ref ASNZS:2918:2001
More informationProtective Capony RTC-16
Protective Capony RTC-16 ASSEMBLY AND OPERATION MANUAL Protective Canopy RTC-16 Assembly and Operation Manual CONTENT: 1 APPLICATION...3 2 OPERATION CONDITIONS...3 3 TECHNICAL SPECIFICATIONS...3 4 DELIVERY
More informationConcentric Vent/Air System Supplement
Concentric Vent/Air System Supplement This document is intended to be used by a qualified heating contractor or service technician. Read all instructions within this document and within the CHAL- LENGER
More informationSflue. Twin Wall Flue TOVE TOVE. Economical twin wall, insulated stainless steel chimney system for wood burning/multi fuel stoves
TOVE Sflue TOVE Sflue Twin Wall Flue Economical twin wall, insulated stainless steel chimney system for wood burning/multi fuel stoves 100% Manufactured in the UK Introduction Sflue chimney system has
More informationFor door closer systems with hydraulic damping (overhead door closers and floor springs)
PRODUCT INFORMATION AND SAFETY ADVICE For door closer systems with hydraulic damping (overhead door closers and floor springs) The following information and safety advice are directed both to product fabricators
More informationRead and understand this manual for safely usage.
Read and understand this manual for safely usage. This manual describes the product of standard specification. Read the other manual for the product of explosion-proof specification. This manual describes
More informationValkFlat East West - Landscape
ValkFlat East West - Landscape Installation manual Use in combination with the Project Report of the ValkPVplanner Version 06 EN Van der Valk Solar Systems Solar Mounting Systems Please Note Table of contents
More informationRL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL
The RL series of burners covers a firing range from 154 to 2700 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation
More informationDuraLiner. Insulated, double-wall masonry relining. UL 1777, ULC S635, and ULC S640.
DuraLiner Insulated, double-wall masonry relining. UL 1777, ULC S635, and ULC S640. Specifications pplications DuraLiner is a high-temperature, insulated double-wall masonry relining system for use with
More informationInstallation Instructions
Installation Instructions SAVE THESE INSTRUCTIONS Please read this entire manual before you install and use your room heater. Failure to follow instructions may result in property damage, bodily injury,
More informationIgnition Switch Replacement for 850/70 Series ipd # , #
PI-359 12/07 Dedicated to improving vehicle fun, safety & performance Installation Instructions Ignition Switch Replacement for 850/70 Series ipd #9447803, #9447804 SUGGESTED TOOLS Torx bit set includes
More informationInstallation instructions
Installation instructions Holetherm Single-walled flue gas discharge system (EW) 2016 All information in this release is subject to misprints. No liability is accepted for the consequences of misprints.
More informationOriginal instructions JSNY7 Magnetic switch
Original instructions JSNY7 Magnetic switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.jokabsafety.com Read and understand this document Please read and understand this
More informationInstallation instruction
Installation instruction Ci51 www.contura.eu 114 CERTIFICATE Declaration of performance according to Regulation (EU) 305/2011 No. Ci51-CPR-150821-SE-2 PRODUCT Product type Type designation Manufacturing
More informationGas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth
28-15/16 (735mm) Model P36D-NG10 P36D-LP10 Fuel Type Natural Gas Propane Gas Fireplaces Minimum Supply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.25 kpa) 3.8 W.C. (0.95 kpa) 1.1
More informationTHE INSTALLING INSTRUCTION FOR CONCEALED TANK
THE INSTLLING INSTRUCTION FOR CONCELED TNK Important remind: 80mm300kgf FFL ccessories List:. Please read through this Instructions carefully prior to installation, and our company shall not be responsible
More informationELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200
ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200 The GRD 4200 is an electronic earthing equipment for tankers during loading and unloading operations of flammable liquids in places with danger of explosion.
More informationTC54. for architects & designers. Dimensions Clearances Venting
for architects & designers TC54 Series D Dimensions Clearances enting IMPORTANT This booklet is intended as a basic specification guide for architects, designers and builders. Please refer to the Instruction
More informationNatural Gas Service Installation and Meter Clearance Requirements
Natural Gas Service Installation and Meter Clearance Requirements Call SJG s new construction line at 1-844-611-5605 for more information. Builder/Owner/Developer Requirements The clearances in this handout
More informationOperating Instructions. Sniffer Probe
Operating Instructions Sniffer Probe BG 5268BE/E (0611) LP 503 LP 505 LP 510 Product Identification In all communications with Pfeiffer Vacuum, please specify the information given on the product nameplate.
More informationSub-construction for Wall-mounted Longlight
modular skylights Sub-construction for Wall-mounted Longlight Subconstruction for Wall-mounted Longlight at 5-40 pitch modular skylights in a wall-mounted longlight solution, can be installed on a sub-construction
More informationBUILDING STRENGTH GUIDELINES FOR HANDLING PRECAST CONCRETE PIPE AND UTILITY PRODUCTS CONCRETE CONSTRUCTION PRODUCTS
BUILDING STRENGTH GUIDELINES FOR HNDLING PRECST CONCRETE PIPE ND UTILITY PRODUCTS CONCRETE CONSTRUCTION PRODUCTS Table of Contents Safety Factors... 1 P50 SL Universal Lifting Eye... 2 Inspection and Maintenance...
More informationTurbocharger / TPL-C Original assembly instructions English
Assembly Instructions Turbocharger / TPL-C Original assembly instructions English This document is valid for the TPL-C series: TPL79-C Purpose The assembly instructions explain how the ABB turbocharger
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS 2190 Dagenais Blvd.West Laval (Quebec) Canada H7L 5X9 Tel. : 514.337.4415 Fax : 514.337.4029 info@burcam.com see us at www.burcam.com VERSION Z MODELS 300500 SUMP PUMPS Your pump
More informationPMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00
PMA 31-G English 1 Information about the documentation 1.1 About this documentation Read this documentation before initial operation or use. This is a prerequisite for safe, trouble-free handling and
More informationPE45 AMAZON MONKEY BARS OWNER'S MANUAL
PE45 AMAZON MONKEY BARS OWNER'S MANUAL WARNING! The disassembled product may contain small parts which pose a choking hazard to children under 3. IMPORTANT: This product may contain sharp points and small
More informationDESIGN DOUBLE PANE BATH SCREEN
DESGN DOUBLE PNE BTH SCREEN DBDSC1060 NSTLLTON NSTRUCTONS MPORTNT - Please read before installation Please read these instructions carefully before starting installation and keep in a safe place for future
More informationDunbrik A1 Concrete Flue Liners
Dunbrik A1 Concrete Flue Liners System Guide Firebelly stove FB2 woodburner in pewter domestic flue & chimney systems Certificate No.FM24104 Benefits of a Chimney A chimney adds appeal to a house A real
More informationFlexdip CYH112. Technical Information. Holder system for water and wastewater assemblies
Technical Information Flexdip CYH112 Holder system for water and wastewater assemblies pplication Water treatment Wastewater treatment Plant design CYH112 is a modular holder system for sensors and assemblies
More informationSEMPEO SQA Unit Code FP3G 04 Forming and assembling electrical cable enclosure and support systems
Forming and assembling electrical cable enclosure and support Overview This standard covers a broad range of basic competences that you need to form and assemble electrical cable enclosure and support
More informationForming and assembling electrical cable enclosure and support systems
Unit 034 Forming and assembling electrical cable Level: 2 Credit value: 13 NDAQ number: 500/9514/6 Unit aim This unit covers the skills and knowledge needed to prove the competences required to form and
More informationINSTALLATION MANUAL M-WRG-S... for surface-mount and flush-mount installation of M-WRG ventilation units VENTI LATI O N TH E RI GH T WAY
INSTALLATION MANUAL V E N T I L AT I O N & H E AT R E C O V E R Y HOME VENTILATION WITH HEAT RECOVERY for surface-mount and flush-mount installation of M-WRG ventilation units Part no. 500-0-0 Week 0/08
More informationELECTRICAL SAFETY INSPECTION REPORT
ELECTRICAL SAFETY INSPECTION REPORT ACTIVE COMPOSITE MILLS LTD. Dewan Idris Road, Zirabo, Ashulia, Savar, Dhaka, Bangladesh Factory List: 1. Active Composite Mills Ltd. Inspected by: Hemlal Report Generated
More informationGAS BOILER SYSTEM COMMISSIONING CHECKLIST
GAS BOILER SYSTEM COMMISSIONING CHECKLIST This Commissioning Checklist is to be completed in full by the competent person who commissioned the boiler as a means of demonstrating compliance with the appropriate
More informationKOMPOZITOR CHIMNEY SYSTEMS FURANFLEX-RWV CHIMNEY LINING SYSTEM
Kompozitor Plastics Development Ltd Széchenyi út 60 Vecsés 2220 Hungary Tel: +36 29 554 600 Fax: +36 29 554 610 e-mail: info@kompozitor.hu website: www.furanflex.com APPROVAL INSPECTION TESTING CERTIFICATION
More information1-300 SERIES Endover Rotator Operator s Manual for Morse End-Over-End Drum Rotators Series
Contents Page Receiving Procedures.................... 1 Warranty............................. 1 Safety Information..................... 1-2 Machine Description................... 3 Operating Instructions....................
More informationEcologix Environmental Systems, LLC
Ecologix Environmental Systems, LLC 120 Ansley Way Roswell, GA 30075 Toll Free: 888-326-2020 Tel: 770.993.8292 Fax: 770.993.8824 Email: info@ecologixsystems.com Web Site: www.ecologixsystems.com D412 Ozone
More informationSub-construction for longlight
modular skylights Sub-construction for longlight Sub-construction for longlight at 5-25 pitch modular skylights installed in a longlight solution are build on a sub-construction made of wood, steel or
More informationR10 RAINWATER DRAINAGE SYSTEMS
R10 RAINWATER DRAINAGE SYSTEMS To be read with Preliminaries/General conditions. GENERAL INFORMATION/REQUIREMENTS 110 GRAVITY RAINWATER DRAINAGE SYSTEM - Rainwater outlets: Proprietary (see clause 365)
More informationmin. 50min. 65min. PIT / P3 / P4 Ø
Flush design Stop switch, IP 65 Equipment consisting of (schematic overview) 2 78 23 Actuator Anti-twist ring 2... 6 Pressure ring = Screw terminal Product can differ from the configuration. Bayonet flange
More informationThese installation instructions cover the installation and operation of Jetmaster Inset and Freestanding Barbecues
These installation instructions cover the installation and operation of Jetmaster Inset and Freestanding Barbecues ADDRESS Jetmaster Fires Ltd Unit 2, Peacock Trading Estate Goodwood Road Eastleigh Hampshire`
More informationNuheat WEATHER-READY ROOF & GUTTER DE - ICING SYSTEM. 13mm Self-Regulating Heating Cable. UV Resistant Polyolefin Outer Jacket
Nuheat WEATHER-READY ROOF & GUTTER DE - ICING SYSTEM 13mm Self-Regulating Heating Cable UV Resistant Polyolefin Outer Jacket Tinned Copper Braid Polyolefin Inner Jacket Fire Resistant Conductive Core 16
More informationSOLO HE A. Compact heat only boiler. Solo installer brochure 8pages.indd 1
Q 9H 8 8 38 D B 88 d, 44 or 7 df 12 ra 0 B d oa R ey kn oc H ff O e at st.e nd m I d co oa. R 47 n s2 to re rn pa ho gs n,t i A at t3 he ni. U ww w SOLO HE A Compact heat only boiler 17/08/2012 17:06 Solo
More informationInstallation, Operation & Maintenance Manual
Original Instructions Installation, Operation & Maintenance Manual Sentry IC Indexing Cabinet Automatic Sampling Accessories S-AS-IOM-00462-2 11-17 Do not install, maintain, or operate this equipment without
More informationEXETER TOWNSHIP HOOD AND DUCT SYSTEMS FOR COMMERCIAL KITCHENS
HOOD AND DUCT SYSTEMS FOR COMMERCIAL KITCHENS POLICY STATEMENT This policy applies to NEW Hood and Duct systems. The Authority Having Jurisdiction will not waive major criteria in the applicable standards
More informationCONTACT INFORMATION. PV System will require a separate Electrical Permit.
SOLAR APPLICATION P. O. Box 72 Mountlake Terrace, WA 98043 Phone 425.744.6267 Fax 425.778.6421 PermitSpecialist@ci.mlt.wa.us www.cityofmlt.com Application # Job Site Address Single-Family Residential Multi-Family
More informationARGOS: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2. PRE-INSTALLATION 3. INSTALLATION 4. OPERATION 5. TESTING. Keep for future use
ARGOS: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2 2. PRE-INSTALLATION 3 3. INSTALLATION 5 4. OPERATION 9 5. TESTING Keep for future use 10 1. TECHNICAL DATA WEIGHT AND DIMENSIONS: Dimensions Firebox W531
More informationPHAROS: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2. PRE-INSTALLATION 3. INSTALLATION 4. OPERATION 5. TESTING. Keep for future use
PHAROS: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2 2. PRE-INSTALLATION 3 3. INSTALLATION 5 4. OPERATION 9 5. TESTING Keep for future use 10 1. TECHNICAL DATA WEIGHT AND DIMENSIONS: Dimensions Firebox W531
More informationValkPitched - Insert
ValkPitched - Insert Installation manual Use in combination with the Project Report of the ValkPVplanner Version 14 EN Van der Valk Solar Systems Solar Mounting Systems Please Note Table of contents This
More informationPIP PCEPA003 Process Analyzer System Field Installation Guidelines
January 2016 Process Control PIP PCEPA003 Process Analyzer System Field Installation Guidelines PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities,
More informationPlease read these instructions before use and retain for future reference
User Manual DPF-830 Please read these instructions before use and retain for future reference 1 CONTENTS 1. Safety Precautions ------------------------------------------------------------------------------3
More informationOPERATION MANUAL. Beam Clamp with Shackle
Beam Clamp with Shackle OPERATION MANUAL This operation manual is intended as an instruction manual for trained personnel who are in charge of installation, maintenance, repair, etc. Before equipment use,
More informationValkFlat East West - Portrait
ValkFlat East West - Portrait Installation manual Use in combination with the Project Report of the ValkPVplanner Version 05 EN Van der Valk Solar Systems Solar Mounting Systems Please Note Table of contents
More informationROOF MOUNT KIT OWNERS MANUAL
ROOF MOUNT KIT OWNERS MANUAL Made in the USA by: Primus Wind Power, Inc. 938 Quail St. Lakewood, CO 80215 Phone: (303) 242-5820 www.primuswindpower.com AIR is a trademark of Primus Wind Power, Inc. ROOF
More informationModular Coldroom Installation Manual
Modular Coldroom Installation Manual May 2005 Disclaimer: The information contained in this installation guide is provided "as is". Bromic Pty Ltd does not warrant the accuracy, adequacy or completeness
More informationHAKA 63/51W, 63/51WI A + Technical data
HAKA 63/51W, 63/51WI A + Operation when directly connected to chimney HAKA 63/51 W HAKA 63/51 WI Tested according to EN 13229 EN 13229 Nominal heat power / Power absorbed to water 14,5 / 10 kw 14,5 / 11,3
More information300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP
www.burcam.com 2190 Dagenais Blvd. West TEL : 514.337.4415 LAVAL (QUEBEC) FAX : 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during
More informationJust a few clicks away from a heating system
Just a few clicks away from a heating system diagnosis. testo 320.The highly efficient flue gas analyzer. testo 320 Efficient measurement with only one instrument. The testo 320 is your reliable partner
More informationMOUNTING SYSTEM FOR PITCHED ROOF WITH TILES. mounting system for pitched roof with tiles for solar panels in landscape setup. Rev
MANUAL EN MOUNTING SYSTEM FOR PITCHED ROOF WITH TILES mounting system for pitched roof with tiles for solar panels in landscape setup ESDEC BV 2016 TABLE OF CONTENT 1. Introduction 1 2. General installation
More informationCaution: FOR YOUR SAFETY
Caution: FOR YOUR SAFETY This Decorative Open Gas Fire is designed and approved for insertion into an existing masonry fireplace and chimney, wall cavity or false chimney provided that the installation
More informationGas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth
P33 Zero Clearance Direct Vent Gas Fireplace P33 WITH THE FLUSH OR BAY FRONT Model P33-NG4 P33-LP4 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) Manifold Pressure
More informationKAZAN: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2 2. PRE-INSTALLATION 3 3. INSTALLATION 6 4. OPERATION TESTING 11. Keep for future use
KAZAN: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2 2. PRE-INSTALLATION 3 3. INSTALLATION 6 4. OPERATION 10 5. TESTING 11 Keep for future use 1. TECHNICAL DATA WEIGHT AND DIMENSIONS: Dimensions Firebox W642
More informationCombustion Laboratory Unit C492
Combustion Laboratory Unit C492 Figure 1: C492 Unit with Optional C492A fitted Purpose built Combustion Chamber, with Instrumentation Designed for Supervised Student Operation Oil or Gas Burners Available
More informationAXIS T91G61 Wall Mount
Installation Guide Legal Considerations Video and audio surveillance can be regulated by laws that vary from country to country. Check the laws in your local region before using this product for surveillance
More informationValkPitched - Clamp. Installation manual. Van der Valk Solar Systems. Use in combination with the Project Report of the ValkPVplanner
ValkPitched - Clamp Installation manual Use in combination with the Project Report of the ValkPVplanner Version 18 EN Van der Valk Solar Systems Solar Mounting Systems Please note Table of contents This
More informationStainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K
T Premium Panel, protection category IP 69K IP 69 K.6 H H H Optionally with or without keyboard housing Resistant to high-pressure cleaning (protection category IP 69K). The seal lies between two surfaces
More informationAPPENDIX "B" November 5, 2002 Page 1 of 6 BOILERSMITH LTD. STACKS AND BREECHING
APPENDIX "B" November 5, 2002 Page 1 of 6 BOILERSMITH LTD. STACKS AND BREECHING NOTE The Stack and Breeching shall be installed in conformance with national, regional and local codes and standards and/or
More informationSEMPEO SQA Unit Code H Carrying out pipe fitting activities
Overview This standard covers a range of basic pipe fitting competences that will prepare you for entry into the engineering or manufacturing sectors, creating a progression between education and employment,
More informationLevel 2 NVQ Certificate in Wall and Floor Tiling (Construction) Qualification Specification
Qualification Specification ProQual 2017 Contents Page Introduction 3 Qualification profile 3 Qualification structure 4 Centre requirements 5 Support for candidates 5 Assessment 6 Internal quality assurance
More informationHANDING-OVER CERTIFICATE - SCAFFOLDING
HANDING-OVER CERTIFICATE - SCAFFOLDING Contractor : Site : Contractor. customername Site. Site name Date : Time : Erected by : Signature : Description of section handed over Job specification. description
More informationPart E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,
Part E Pack Dear Colleague, This is the first 2017 update to the Part E Robust Details Handbook. In this update pack, we have focussed on clarifying the situation on incorporating underfloor heating (UFH)
More informationInstallation, Inspection and Maintenance of Dry Type Transformers
Dry Type TX 1 of 8 Installation, Inspection and Maintenance of Dry Type Page 1 of 8 Dry Type TX 2 of 8 Table Of Contents Page Number 1. General... 3 2. Installation... 3 3. Safety Inspections... 4 4. Safety
More informationGENERAL INSTALLATION GUIDELINES
GENERAL INSTALLATION GUIDELINES VIEW ACTIS HYBRID VIDEOS ON General information HYBRIS is an insulation material generally used for roof, wall, ceiling and suspended timber floor applications. HYBRIS is
More informationFLAMABILITY TESTS FOR ELECTRICAL CABLES
Tests on electric and optical fibre cables under fire conditions Description E 60332-1-2 E 60332-2-2 acc. to IEC 60332-1-2 acc. to IEC 60332-2-2 Tests for flame Tests for flame propagation for a single
More information