Innovations in LFG Wellhead Flow Control and Gas Well Dewatering. David Kaminski QED Environmental Systems Inc. Dexter, MI & San Leandro, CA

Size: px
Start display at page:

Download "Innovations in LFG Wellhead Flow Control and Gas Well Dewatering. David Kaminski QED Environmental Systems Inc. Dexter, MI & San Leandro, CA"

Transcription

1 Innovations in LFG Wellhead Flow Control and Gas Well Dewatering David Kaminski QED Environmental Systems Inc. Dexter, MI & San Leandro, CA

2 The challenge of managing LFG systems Gas collection and control systems are typically viewed as mechanical systems gas wells and wellhead controls, collection system piping and extraction blowers with expectation of how these systems will behave based on engineering practices and experience In fact, they are combined mechanical and biological systems, and the biological component greatly affects how the mechanical system behaves and performs Gas generation & collection rates are affected by barometric pressure, seasonal temps, waste stream, precipitation, etc. Biodegradation of waste surrounding the gas wells can impede gas flow, liquid removal and cause silting and clogging of wells We design to collect gas, but we have to manage liquids in system to get the gas and maintain regulatory compliance

3 LFG System Goals: What are operators trying to achieve? Control odors and maintain compliance with LFG emission regulations (#1 survey response) Avoid NSPS exceedance for Pressure (negative), Temperature (131 F) and Oxygen (5%) (#2 response) Maximize LFG energy content (flow rate and methane concentration) where gas is utilized (#3 response) Maintain steady vacuum across all wells (#4 response) Manage accumulation of leachate/condensate in gas wells & piping (#5 response) Control air leaks at the wellhead, flexible couplings and hoses (#6 response)

4 A new trend in LFG well field management For nearly three decades, LFG collection systems were designed using devices for controlling and measuring the gas flow at each well that weren t ideal for LFG Four years ago, QED saw that our customers needed greater control over their LFG well fields. We designed the first purpose built LFG wellhead - the Quick-Change Orifice Plate wellhead with our Precision Fine-Tune Control Valve, introduced in January This technology shift is driving a change in LFG well field best management practices Adjusting the well for FLOW rather than applied vacuum Using data to guide well tuning rather than a rule-of-thumb Viewing the well field holistically rather than well-by-well

5 Traditional LFG wellhead designs PVC gate valves were designed for controlling liquids, not for regulating gas flow small adjustments in valve opening can result in large changes flow and applied vacuum Pitot tubes and venturis have flow measurement accuracy errors as high as œ20%. Union orifice plates can be difficult to change and are easily broken when stuck. Flexible rubber couplings can t support weight, causing air leaks. There s no access for liquid level measurement, so vacuum is shut off and wells are opened or liquid levels aren t measured at all.

6 Advantages Flow Control Using Gate Valves Lower initial cost than other valve designs Widely available Disadvantages Closed Open Non-rising stem, so operator can t observe valve opening position Plastic threads can strip, plastic handle can break off with age Seals can fail, dirt and grit can get into threads and gate track, and extreme cold and heat can make valve difficult or impossible to adjust or cause the valve stem to shear when excessive force is applied Valve is fully open in just 3-4 turns, flow adjustment isn t linear and is difficult to regulate, especially at low flow rates

7 Traditional Gate Valve

8 Angle Globe Valve for Gas Flow Control Designed to provide variable flow control in compressible fluids (gases) Larger sizes (2 and above) not effective at low flow rates (10-15 CFM) Plastic parts are still susceptible to weathering and failure As with PVC gate valves, operator has no indication of valve position Commercially available 2-inch PVC angle globe valves cost $230 - $290

9 Precision Fine Tune Control Valve Patented flow-tuned valve design provides precise, linear control of flow from fully closed to maximum flow Rising stem design and highly visible metered scale allows observation of valve position setting, making it easy to quickly return to the exact setting if the valve must be closed Rugged stainless steel valve stem and handle make it more durable in harsh outdoor environments

10 Precision Fine Tune Control Valve

11 Case Study South Texas Landfill Well 54 The QED Precision Fine-Tune Valve eliminated wide swings in methane concentration and air leaks into the well, improving the overall gas quality while avoiding NSPS exceedance

12 The Value of Better Flow Control Improved Gas Heat Content Additional Annual Gas 1% Methane Increase Gas Value ($/mmbtu) 1 CFM 5 CFM 10 CFM 25 CFM 50 CFM 100 CFM $1.50 $8 $40 $80 $200 $400 $800 $2.00 $11 $55 $110 $275 $550 $1,100 $2.50 $13 $65 $130 $325 $650 $1,300 $3.00 $16 $80 $160 $400 $800 $1,600 $3.50 $18 $90 $180 $450 $900 $1,800 $4.00 $21 $105 $210 $525 $1,050 $2,100 As little as a 1% increase in methane concentration at a gas value of $2.00/mmBtu in a 50 CFM well can pay for upgraded wellhead and well cap in as little as 12 months Try the latest QED LFG Calculator at

13 Common LFG Flow Measurement Methods Pitot Tubes are intended to fit a wide range of flow rates, but can easily clog with condensate and corrosion, and have poor accuracy at gas flows under 20 CFM (œ5-10% at best, œ20% or greater at worst) Venturis are also a one size fits all device, but create significant pressure drop at high flows (>12 SCFM) and insufficient pressure drop for reliable measurement at flows under 20 SCFM Orifice Plate sizes can be selected to match changes in flow rates, but changing plates in unions can be time consuming, requires shutting off gas flow and breaking pipe connections, and gas techs can t see the plate size without opening the pipe union

14 Pitot Tube Wellhead The static port measures static (low) pressure The impact tube measures flow (high) pressure

15 Pitot Tube Design Requirements (From Dwyer Technical Specifications for Pitot Tube Systems) For accuracy of plus or minus 2%, the duct diameter should be 30 times pitot tube diameter or greater (for 3/16 tube, pipe size should be or greater) 3/16 Typical LFG Pitot tube assembly

16 Pitot Tube Operating Conditions If the impact or static tube becomes clogged, measurement accuracy can be affected. The instrument will give you a reading, but you won t have any indication that it s not accurate. If the gas velocity is low, the differential pressure is very small and hard to measure accurately. Error in the instrument could be greater than the measurement! Pitot tubes don't work very well for very low velocities. Typical LFG flow velocities in 1 3 pipe diameters often fall well below the minimum velocity to maintain œ3% accuracy Meters used to measure LFG flows with Pitot tubes don t meet the needed accuracy to attain accurate measurements: GEM 5000: 1.6 WC (œ4mbar) typical, 6.0 WC (œ15 mbar) max Elkins Envision: œ WC low range

17 Pitot tube wellheads don t generate sufficient pressure drop in many wells to get an accurate measurement with common LFG instruments. In a 2 wellhead, 0.5 WC pressure drop isn t achieved until 40 CFM

18 Typical Wellhead Gas Flow Velocities While LFG wells can achieve flow rates e 100 CFM, they are typically lower, and can easily be below 10 CFM Velocity Too Low Flow velocities in wellhead pipe sizes of 1 to 3 are often too low to get accurate measurements with Pitot tubes Orifice plate wellheads have the advantage of changing orifice sizes to match the gas flow to achieve desired pressure drop for accurate measurement

19 Orifice plate wellheads have the advantage of matching the plate size to achieve the desired pressure drop at any flow rate

20 Performance of Orifice Plates vs Pitot Tubes Values derived using Industrial Flow Calculator for LFG at 100 F, 50/50 mixture of CH4 and CO2 at 20 WC vacuum and 100% humidity. Pitot tube values from manufacturers data.

21 Quick-Change Orifice Plate System Uses proven orifice plate technology for accurate and repeatable flow measurement Plates can be swapped out under vacuum in seconds to achieve desired differential pressure No time wasted shutting down the control valve, breaking pipe connections or rebalancing the well Removable dust cover allows for easy confirmation of plate size, reducing reporting errors

22 The Quick-Change Orifice Plate Wellhead is the only flow measurement device that can be cleaned without shutting down the well, breaking a pipe union or removing the wellhead Simply loosen the Quick-Change collar and slide the plate out to remove condensate build-up. Plate can be quickly wiped clean if desired. Slip the clean plate back into the wellhead and tighten the collar to take an accurate flow measurement

23 NEW Color-Coded Plastic Orifice Plates The new molded orifice plate kits from QED have several advantages over metal or other plastic orifice plates Color coded for easy size identification Orifice diameter is clearly marked in raised type on each plate Strong, glass-filled high-temperature nylon plastic won t break or corrode, and don t get hot like metal plates Lightweight a kit of six plates can be easily carried in you pocket

24 NEW QED Easy Port Wellhead Fittings The new Easy Port molded, positive-seal fittings are easy to open, easy to attach and remove gas meter tubing Won t leak between uses due to weathering or heat Bird proof! Birds can t pull off caps and cause air/gas leaks Strong, glass-filled engineering plastic won t break or corrode Unique barb design - easy connection/removal, positive seal

25 LFG Flex Hose LFG flex hose, made from clear flexible vinyl (PVC), is subject to weathering from UV exposure and the heat from LFG Over time, the hose will discolor or brown, losing flexibility and eventually cracking, causing air leaks into the gas system

26 NEW Solarguard UV-resistant Flex Hose

27 Typical Solarguard Installations

28 What s Next from QED? 2 nd Generation Wellhead Molded Design All major components molded from highstrength, high-temp engineering plastics Two-piece valve design improves serviceability Operating temperatures to 180 F Self-regulating LFG control valve Keeps vacuum or flow at desired set point Uses a solar-powered actuator that wakes up several times each day, makes adjustment if necessary Intended to reduce swings in flow from changes in barometric pressure and system vacuum to maintain compliance and maximize gas extraction for energy use

29 What s next in LFG management? NSPS/EG Proposed August 27, 2015 revisions to the New Source Performance Standards (NSPS) and Environmental Guidelines (EG) will change some aspects of wellfield management and reporting, and may pull more sites under those rules The good news: elimination of monthly PTO reporting, HOVs for T and O2, and the 5/15 compliance cycle; site will still measure but not report T & O, and longer compliance time for P issues The bad news(?): EPA target is to further reduce emissions NMOC emission trigger for GCCS drops from 50 Mg to 34 Mg Surface emission monitoring will add measurement at every penetration in the landfill to current site walk/grid approach Better wellbore seals, gas well dewatering and better wellhead flow control are being encouraged as Best System of Emission Reductions (BSER)

30 Typical Landfill Gas Well Components LFG Wellhead Flow Control Valve Gas Collection Header Pipe Annular Seal Perforated Pipe/Screen Rock or Gravel Backfill

31 Why Manage Landfill Liquids? Leachate Collection & Recirculation Regulatory compliance (maximum head limit against liner) Minimize side slope seeps, ponding and odors Gradient control in unlined landfills to prevent leakage Leachate recirculation to accelerate gas production and treat leachate (reduce BOD/COD) Condensate & Leachate in Gas Wells/Piping Maximize gas flow from wells to increase profits, reduce fugitive emissions and odors Reduce liquid accumulation in piping (low spots, sumps) Maintain steady operation of power generation systems Prevent damage to blowers, generators and flares

32 Leachate Flow in Typical MSW Landfill Gas Header Pipe Flare/ LFGTE Plant Daily Cover Material Leachate Flow Leachate Plant Gas Extraction Wells Waste Cells Monitoring Probes

33 Daily Cover Practices Common practice of using soil as daily cover creates hydraulic barrier to leachate movement Results in lateral movement of leachate and pockets of perched leachate, high liquid levels in gas wells Using alternative daily cover materials can improve leachate collection efficiency, minimize seeps and ponding, reduce liquid accumulation in gas wells and improve gas movement through the waste material Spray-on foam, recycled cardboard or tarps as daily cover allow for better vertical leachate movement and distribution in waste Yard waste can be used as daily cover, breaks down over time and generates additional gas Compost has also been used, very effective at controlling odors

34 PROBLEM: Leachate/condensate accumulate in gas wells, blocking screen openings and reducing gas flow Long-term accumulation can clog the well screen and backfill, leading to permanent reduction in gas flow from the well Leachate recirculation can accelerate leachate buildup in gas wells

35 Liquid in LFG wells and surrounding waste cause gas and liquid to compete for pore spaces in waste and results in high shut-in gas pressure, causing leachate seeps or blow-outs and silt in wells while reducing gas collection rates

36 Gas Flow vs. Liquid Levels in Wells White Areas = High gas flow Blue Areas = Low/no gas flow (Clarke, 2007) LFG Flow, SCFM Blue Areas = High Liquid Levels

37 SOLUTION: Install a dedicated pumping system to dewater the well to increase gas flow and maintain long-term viability of the well Increases the zone of influence around well, reducing LFG emissions, odors and air leaks into system from over pulling, improving gas quality and maintaining regulatory compliance

38 Zone of Influence Leachate accumulation effectively shortens the length of the well intake and reduces the zone of influence in the waste Dewatering the well and surrounding waste can increase the zone of influence with no increase in vacuum, reducing the risk of air infiltration and maintaining gas quality Dillah, McCarron and Panesar, 2004

39 LFG Collection Rate Improvement Gramacho Landfill, Brazil LFG Flow (SCFM) Change in LFG Flow Well Before Pumping* After Pumping SCFM % % % % % % % % % % % TOTAL % * Average of 6-8 flow measurements taken over 30 days (August 2009) Single flow measurement taken after dewatering (October 2009)

40 Gas Well Dewatering - Economics Additional Annual Gas 50% Methane Gas Value ($/mmbtu) 1 CFM 5 CFM 10 CFM 25 CFM 50 CFM $1.50 $394 $1,970 $3,940 $9,850 $19,700 $2.00 $525 $2,625 $5,250 $13,125 $26,250 $2.50 $657 $3,285 $6,570 $16,425 $32,850 $3.00 $788 $3,940 $7,880 $19,700 $39,400 $3.50 $920 $4,600 $9,200 $23,000 $46,000 $4.00 $1,050 $5,250 $10, 500 $26,250 $52,500 As little as 5 CFM additional gas flow per well at $2.50/mmBtu can pay for a $3,300 dewatering pump system in just one year, with additional annual revenue generated thereafter

41 Benefits of LFG Well Dewatering Maximize gas collection rates and zone of influence Increase revenues where gas is utilized Reduce fugitive emissions, odors Maintain regulatory compliance in gas wells Reduce liquid accumulation in collection piping & sumps Maintain steady operation of generators and flares Prevent damage to blowers, engines and flares Increased useful life of LFG wells by reducing clogging and encrustation of well screens and backfill

42 Landfill Pumping is a Challenge More challenging than nearly any other industrial pumping application Elevated temperatures to +180 F accelerates wear, attacks materials High levels of suspended solids can clog pumps and well screens High dissolved solids clogs pumps, discharge piping and headers Foaming potential can reduce flow rate or cause pumps to stall Viscosity greater than water increases energy needed Corrosives and aggressive organics Extreme ph at some sites (< 1.5 ph)

43 Pumps and leachate don t like each other

44 Gas Well Dewatering Challenges No matter what type of pump is used, some degree of maintenance is required The cost of maintenance over time can be the largest percentage of total life cycle cost QED recognizes that pumps in some wells require frequent maintenance, and some will stall/stop even when maintained QED has introduced design enhancements to reduce maintenance, speed cleaning and reduce downtime and stalling

45 AutoPump *AP4+ designed for easier cleaning * Patent Pending Easier disassembly: removing four bolts on bottom inlet allows complete pump disassembly in minutes no turning of the inlet assembly or O-ring hang-up/dragging Easier service: quick-release clip on actuator rod allows quick float removal for easier cleaning. Pump body has a high-polish ID finish to reduce solids build-up and precision bore sizing to improve O-ring fit Increased durability: All metal parts are 304SS or higher for improved corrosion resistance; plastic parts are high-strength & hightemperature engineering plastics (PVDF, PEEK) Increased warranty: 5-year full warranty with no pro-rating in later years

46 AutoPump AP4+ Design Enhancements Wide-Slot Float actuator rod slot is wider and cut through to center to prevent solids lock-up between float and actuator rod Low-Friction Float Coating reduces build-up of solids on float to extend cleaning intervals, speeds cleaning and reduces chance of damaging float during cleaning High-polish 316L SS Center Rod reduces friction, solids adhesion and corrosion Low-Friction Float Guide Plate made from engineering plastic to have lower friction than steel and prevent scratching of center rod Standard Float vs. Wide-Slot Float

47 AutoPump AP4+ Design Improvement New Air Valve Mechanism Design The new captured pin design eliminates need for fasteners, clips or cotter pins at valve stem Improved reliability, easier to service exhaust seat is easier to adjust Now on all AP4+ models!

48 Net result the first low-maintenance air-powered pump: The Ultra lasts up to 10 times longer between cleanings and takes up to 50% less time to clean The Ultra combines all of the design features and rugged reliability of the AutoPump AP4+ in an innovative design that reduces build-up of solids and sticky deposits on the float and center rod Greater reliability in challenging applications Fewer pump pulls for maintenance Cleaning is faster and easier

49 Design Features Non-stick float and electro-polished center rod reduce solids buildup, low-friction engineered plastic guide plates reduce pump stalling All metallic parts are 316-grade SS for greater corrosion resistance and reliability Non-stick, high polish finishes make cleaning easier can be as easy as wipe and rinse

50 Field tests compared the new AutoPump Ultra to existing pumps and reported the following results: Maximum uptime Minimum Downtime Teardown and cleaning took absolutely no effort No soaking required Only needed a water spray to clean Removed residue with some clean water and the swipe of a hand Easier to clean by 50% It s been running for four months and I haven t had to clean it yet!

51 Ultra pump beta test after 1 year 10/20/15

52 Annual Pump Cleaning Savings with AutoPump Ultra Standard Pump AutoPump Ultra Cleaning Frequency Pump Pulls/Year AP Ultra Frequency Pump Pulls/Year Annual Pulls Saved $100/pull $150/pull $200/pull 4 weeks weeks 3 10 $ 1,000 $ 1,500 $ 2,000 2 weeks 26 8 weeks 7 19 $ 1,900 $ 2,850 $ 3,800 2 weeks weeks 3 23 $ 2,300 $ 3,450 $4,600 1 week weeks 3 49 $ 4,900 $ 7,350 $ 9,800 Using the AutoPump AP4 Ultra and reducing your cleaning frequency from monthly to quarterly at $100 per cleaning event saves $800 annually and frees up as much as 16 hours of technician field time

53 Pull puller tool to speed maintenance Designed to guide pump tubing out of the well without kinking and to reduce lifting effort Deep vee roller bolts onto flange or straps to outside of 6 & 8 well casings Currently being field tested at two sites with positive feedback

54

55

56 What s next in air-powered pumps? Buildup of precipitate solids on pumps, piping and wells is the single toughest problem to solve. Approaches have included chemical amendments and alternative designs for well, piping and pumps. One possible solution to increase operating time between maintenance pump pulls is to increase operating clearances on key air-powered pump components.

57 AODD Pumps An Alternate Approach for Challenging LF Pump Applications Air-operated dual diaphragm (AODD) can be an alternative to submersible pumps for applications where chemistry, solids loading or physical limitations exist, such as: LFG wells Condensate sumps Horizontal Gas Collectors Side slope leachate risers QED combines class-leading AODD technology with all-pneumatic control systems designed for landfills

58 AODD Pump Applications Cage frame mount for easy transport and temporary use Dewatering a horizontal gas collector Mounted inside a condensate sump

59 Questions? David Kaminski QED Environmental Systems, Inc. Phone: Kansas contact: Bill Reetz A Better Earth, LLC Tel: Bill@ABetterEarthLLC.com

Engineered Solutions for Landfill Gas Well Field Management

Engineered Solutions for Landfill Gas Well Field Management Engineered Solutions for Landfill Gas Well Field Management December 17, 2013 Brad Peake New Products Manager QED Environmental Systems Inc. Ann Arbor, Michigan - San Leandro, California Copyright QED

More information

Innovative Wellhead Tools for Landfill Gas Management

Innovative Wellhead Tools for Landfill Gas Management Innovative Wellhead Tools for Landfill Gas Management September 27, 2012 Brad Peake New Products Manager QED Environmental Systems Inc. Ann Arbor, Michigan - San Leandro, California Copyright QED Environmental

More information

Managing Landfill Liquids to Maximize Landfill Gas Collection Efficiency

Managing Landfill Liquids to Maximize Landfill Gas Collection Efficiency Managing Landfill Liquids to Maximize Landfill Gas Collection Efficiency David Kaminski QED Environmental Systems Inc. Ann Arbor, Michigan - San Leandro, California Copyright QED Environmental Systems,

More information

Managing Landfill Liquids to Maximize Landfill Gas Collection Efficiency

Managing Landfill Liquids to Maximize Landfill Gas Collection Efficiency Managing Landfill Liquids to Maximize Landfill Gas Collection Efficiency David Kaminski QED Environmental Systems Inc. Ann Arbor, MI/San Leandro, CA Copyright QED Environmental Systems, Inc. 2010; all

More information

Nuts and Bolts Design, Construction and Operation of LFGTE Projects

Nuts and Bolts Design, Construction and Operation of LFGTE Projects Nuts and Bolts Design, Construction and Operation of LFGTE Projects Mississippi LFG Energy Workshop U. S. EPA Landfill Methane Outreach Program April 25, 2002 Regulatory Framework LFG Regulatory Framework

More information

HDPE WATER CONTROL DEVICES

HDPE WATER CONTROL DEVICES HDPE WATER CONTROL DEVICES WHY HDPE? HDPE (high density polyethylene) is an extremely rugged thermoplastic that has been used in the water and wastewater industries for decades. Not to be confused with

More information

Innovations for Improved LFG Collection

Innovations for Improved LFG Collection NW Regional SWANA Symposium Troutdale, Oregon April 30, 2015 Innovations for Improved LFG Collection Jason MacKenzie, Project Manager Engineering & Design Gas Collection Systems Biogas Cleanup Biogas-to-Energy

More information

Overview of Gas Collection and Control Systems. 9, December 2010 Novi Sad, Serbia

Overview of Gas Collection and Control Systems. 9, December 2010 Novi Sad, Serbia Overview of Gas Collection and Control Systems 9, December 2010 Novi Sad, Serbia 1 Overview Objectives of LFG Collection/Control Biogas Recovery Modeling Elements of a LFG collection System 2 Objectives

More information

Innovations for Improved LFG Collection

Innovations for Improved LFG Collection NW Regional SWANA Symposium Troutdale, Oregon April 30, 2015 Innovations for Improved LFG Collection Jason MacKenzie, Project Manager Engineering & Design Gas Collection Systems Biogas Cleanup Biogas-to-Energy

More information

LANDFILL GAS CONTROL SYSTEMS: DESIGN AND CONSTRUCTION CONSIDERATIONS. Mike Bradford, P.E.

LANDFILL GAS CONTROL SYSTEMS: DESIGN AND CONSTRUCTION CONSIDERATIONS. Mike Bradford, P.E. LANDFILL GAS CONTROL SYSTEMS: DESIGN AND CONSTRUCTION CONSIDERATIONS Mike Bradford, P.E. 2 Today s Agenda SOLUTIONS YOU CAN COUNT ON. PEOPLE YOU CAN TRUST. What are we controlling? FOCUS: How do we control

More information

TYPES OF SEWAGE PUMPS. Solids Handling Pumps: Grinder Pumps: Effluent Pumps:

TYPES OF SEWAGE PUMPS. Solids Handling Pumps: Grinder Pumps: Effluent Pumps: Effluent Pumps: Effluent pumps are the pumps most often used in small on-site systems. They are designed to pump effluent, the effluent flowing out of a septic tank. This effluent is relatively clear liquid

More information

A Public-Private Partnership to Advance Recovery and Use of Methane as a Clean Energy Source. Landfill Wellfield and Project Components

A Public-Private Partnership to Advance Recovery and Use of Methane as a Clean Energy Source. Landfill Wellfield and Project Components A Public-Private Partnership to Advance Recovery and Use of Methane as a Clean Energy Source Landfill Wellfield and Project Components Outline Objectives of LFG Collection/Control Elements of a LFG collection

More information

Instructions for 12 IGT system

Instructions for 12 IGT system Instructions for 12 IGT system Step 1: IGT Site Preparation Site Location Several factors must be considered when choosing the site for your new In-Ground Trampoline (IGT) system. Since local soil and

More information

Bioreactor Landfill Design

Bioreactor Landfill Design Bioreactor Landfill Design Timothy Townsend, PhD, PE Department of Environmental Engineering Sciences University of Florida ttown@ufl.edu Bioreactor Landfill Design Modern landfill design entails many

More information

INSTRUCTIONS FOR THE ASSEMBLY AND INSTALLATION OF THE VORTOX LIQUID SAMPLER

INSTRUCTIONS FOR THE ASSEMBLY AND INSTALLATION OF THE VORTOX LIQUID SAMPLER INSTRUCTIONS FOR THE ASSEMBLY AND INSTALLATION OF THE VORTOX LIQUID SAMPLER I. SAMPLER SUSPENDED BY CABLE The Vortox Liquid Sampler is a precision instrument manufactured of stainless steel, easy to install,

More information

Landfill Gas Systems

Landfill Gas Systems Landfill Gas Systems A General Overview ASTSWMO STATE SOLID WASTE MANAGERS CONFERENCE Scottsdale, Arizona September 12-14, 14, 2005 Landfill Gas Management Issues/Objectives Topics to be Covered Reasons

More information

FloMax Air Atomizing Nozzles: High Efficiency Nozzles Offer Tight Control of Drop Size and Spray Coverage, Provide Precise Performance.

FloMax Air Atomizing Nozzles: High Efficiency Nozzles Offer Tight Control of Drop Size and Spray Coverage, Provide Precise Performance. Spray Nozzles Spray Control Spray Analysis Spray Fabrication FloMax Air Atomizing Nozzles: High Efficiency Nozzles Offer Tight Control of Drop Size and Spray Coverage, Provide Precise Performance For Applications

More information

High Temperature Aging Cell Instruction Manual

High Temperature Aging Cell Instruction Manual High Temperature Aging Cell Instruction Manual Part No. 760140001EA Rev. D TABLE OF CONTENTS Section Page Figure 1 General Information... 1 2 Safety Considerations... 3 3 Un-pressurized Testing Procedure...

More information

Severe Service Technology, Inc.

Severe Service Technology, Inc. Severe Service Valves Mining - Minerals - Slurry Pipelines Severe Service Technology, Inc. SST 11000 Stancliff Road, Suite 190 Houston, Texas 77099 Tel: (281) 988-8222 Fax: (281) 988-8294 Since its founding

More information

Husky Process Equipment Contractors Guide

Husky Process Equipment Contractors Guide Contractors Guide Air-Operated Double Diaphragm Pumps Product Selection Key Technical Specifications commercial, industrial, marine, mining & more Introduction Pump Selection Key Graco provide durable

More information

Diffused Aeration Piping Equipment

Diffused Aeration Piping Equipment 1.0 General 1.1. The specifications in this section include all components of the Diffused Aeration System with the exception of the individual diffuser units. Refer to additional specification sections

More information

Automated Landfill Gas Collection Increases Landfill Gas Flow and Quality at Oklahoma City Landfill. White Paper

Automated Landfill Gas Collection Increases Landfill Gas Flow and Quality at Oklahoma City Landfill. White Paper Automated Landfill Gas Collection Increases Landfill Gas Flow and Quality at Oklahoma City Landfill White Paper Bill Bingham VP Business Development, Loci Controls, Inc. Co-authored by: Peter Britton Corporate

More information

Valbart Through Conduit Slab Gate Valve (TCSGV)

Valbart Through Conduit Slab Gate Valve (TCSGV) Valbart Through Conduit Slab Gate Valve (TCSGV) The Oil and Gas Industry s Choice for Liquid and Gas Applications Experience In Motion Flowserve Solutions to Keep You Flowing Flowserve is one of the world

More information

Atlas Copco. ZM Oil-free multistage centrifugal pressure and vacuum blowers

Atlas Copco. ZM Oil-free multistage centrifugal pressure and vacuum blowers Atlas Copco ZM Oil-free multistage centrifugal pressure and vacuum blowers 100-40,000 cfm / 2-24 psi / 5-3,600 hp 3-1160 m 3 /m / 100-1700 mbar / 4-2600 kw A ZM for every application Atlas Copco s ZM oil-free

More information

ID-Series Incline/Decline Conveyors

ID-Series Incline/Decline Conveyors ID-Series Incline/Decline Conveyors your Material Handling Specialist ID-SeriesBrochure_modified:ID Series Brochure.qxd 2/5/2009 11:27 AM Page 2 S pa n T ec h Yo u r Ma t e ri a l H a nd li n g S pe c

More information

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY Section Includes: 1. Pipe and fittings. 2. Drain Basin. 3. De-chlorination tablet feeder. 4. Non-pressure transition couplings.

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S SPECIFICATIONS - DETAILED PROVISIONS Section 11294 - Stainless Steel Sluice Gates C O N T E N T S PART 1 - GENERAL... 1 1.01 SUMMARY... 1 1.02 REFERENCES... 1 1.03 DEFINITIONS... 1 1.04 DESIGN REQUIREMENTS...

More information

Weir Valve Selections

Weir Valve Selections Unlined Metal Excellent Cvs Complete Selection of End Connections ASTM Materials Include: Cast Iron ASTM A-126 Class B Ductile Iron ASTM A-395 Grade 60-40-18 Cast Steel ASTM A-216 Grade WCB 316 Stainless

More information

Flow Meters with Float constructive series AF and BF for liquids and gases with remote flow indication

Flow Meters with Float constructive series AF and BF for liquids and gases with remote flow indication Flow Meters with Float constructive series AF and BF for liquids and gases with remote flow indication - Quality design - High corrosion resistance - Reliable measurement principle - Low weight and small

More information

CROSBY H-SERIES DIRECT SPRING SAFETY VALVES

CROSBY H-SERIES DIRECT SPRING SAFETY VALVES DIRECT SPRING SAFETY VALVES Direct spring safety valves that provide comprehensive overpressure protection for ASME Boiler and Pressure Vessel Code Section I, and Section VIII steam safety applications

More information

/ /

/ / Pump stations Solutions designed for traditional dry pit, flood-proof dry pit and wet pit installation What s your view on efficient fluid handling? Is it a question of being able to turn to a single partner?

More information

INIZIATIVE INDUSTRIALI

INIZIATIVE INDUSTRIALI INIZIATIVE INDUSTRIALI S.p.A. Sarplast is a company located in Santa Luce (Pisa, Italy) which has over 35 years experience in the design, manufacturing and supply of Glass-Fiber Reinforced Plastic (GRP)

More information

ANCHORAGE REGIONAL LANDFILL ANCHORAGE, ALASKA LANDFILL GAS COLLECTION AND CONTROL SYSTEM DESIGN PLAN

ANCHORAGE REGIONAL LANDFILL ANCHORAGE, ALASKA LANDFILL GAS COLLECTION AND CONTROL SYSTEM DESIGN PLAN ANCHORAGE REGIONAL LANDFILL ANCHORAGE, ALASKA LANDFILL GAS COLLECTION AND CONTROL SYSTEM DESIGN PLAN Prepared for Municipality of Anchorage Solid Waste Services September 2004 Prepared by 10300 SW Nimbus

More information

3-DEM and ASGCO FLO-CONTROL

3-DEM and ASGCO FLO-CONTROL 3-DEM and ASGCO FLO-CONTROL 3-DEM TRANSFER POINT DESIGN AND FABRICATION 3-DEM Transfer Point Design The performance of transfer chutes is an essential part to the productivity of the conveyor belt systems

More information

VERIS Accelabar. Superior Flow Measurement Accuracy

VERIS Accelabar. Superior Flow Measurement Accuracy VERIS Superior Flow Measurement Accuracy Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. ...A New Idea in Flow

More information

Glass Care. Frame Cleaning

Glass Care. Frame Cleaning Frame Cleaning Glass Care Keeping your windows and doors clean means more than just the glass. Here are some helpful tips for cleaning your window and door frames effectively without damaging them. Vacuum

More information

Madera County Fairmead Landfill. Landfill Gas Extraction and Control System Improvements

Madera County Fairmead Landfill. Landfill Gas Extraction and Control System Improvements Landfill Gas Extraction and Control System Improvements Introduction Tetra Tech BAS Methane Gas Group A team of methane gas professionals, engineers, technicians and construction staff for all landfill

More information

Stainless Steel Aeration Equipment Specification

Stainless Steel Aeration Equipment Specification Section 15 Stainless Steel Aeration Equipment Specification Part 1 - General 1.01 Description A. Scope of Work 1. Furnish, install and test aeration system including air mains, drop pipes, valves, expansion

More information

Keystone Slurry Control Valves Figure 634

Keystone Slurry Control Valves Figure 634 7 The F634 is a light/medium duty slurry control valve, short body style. For control of liquids, gases and light slurries. F634 037 - Scaling service control valve F634 039 - Slurry control valve Features

More information

PRECISION POLYURETHANES

PRECISION POLYURETHANES Company Profile: We at PRECISION POLYURETHANES manufacture and supply various types of Hi - Performance Cast Polyurethane components and other polyurethane products engineered for multipurpose industrial

More information

Vertical Offset Conveyors

Vertical Offset Conveyors VO-Series VO-SeriesBrochure_modified:VO-SeriesBrochure_modified.qxd 2/5/2009 11:20 AM Page 21 VO-Series Vertical Offset Conveyors your Material Handling Specialist VO-SeriesBrochure_modified:VO-SeriesBrochure_modified.qxd

More information

O I L S I G H T G L A S S E S

O I L S I G H T G L A S S E S O I L S I G H T G L A S S E S Round The Clock Oil Inspection The Esco Oil Sight Glasses are designed for simple installation on most equipment. Constructed of durable acrylic, they withstand most petroleum

More information

Announcing a New Standard in Equipment and Product Protection Powerful Temperature- Compensated NEO FF Series Drawer Magnets*

Announcing a New Standard in Equipment and Product Protection Powerful Temperature- Compensated NEO FF Series Drawer Magnets* Powerful New Magnetic Separators from the Leader in Magnetics Announcing a New Standard in Equipment and Product Protection Powerful Temperature- ompensated NEO Series Drawer Magnets* 4 6 Top Performing

More information

Landfill Operations to Improve Installation of Cap and Gas Collection

Landfill Operations to Improve Installation of Cap and Gas Collection Landfill Operations to Improve Installation of Cap and Gas Collection Mr. Amarjit Riat, P.E. Assistant Director, I-95 Landfill Complex Manager County of Fairfax, Virginia Methane to Markets Partnership

More information

SECTION 1000 ENGINEERING SPECIFICATION: AIR STRIPPER (REMOVABLE TRAY)

SECTION 1000 ENGINEERING SPECIFICATION: AIR STRIPPER (REMOVABLE TRAY) SECTION 1000 ENGINEERING SPECIFICATION: AIR STRIPPER (REMOVABLE TRAY) PART 1 GENERAL 1.1 SCOPE 1.1.1 The manufacturer shall furnish a low profile, multi-tray Air Stripper for removal of volatile organic

More information

Air-Operated Double Diaphragm Pumps

Air-Operated Double Diaphragm Pumps Air-Operated Double Diaphragm Pumps FIRST IN QUALITY Total Quality Management is ingrained in the Iwaki Air brand of Air-Operated Double Diaphragm (AODD) pumps, which are manufactured under stringent ISO

More information

Artificial Lift Technique (VI Semester)

Artificial Lift Technique (VI Semester) Artificial Lift Technique (VI Semester) Q.1. What do you mean by artificial lift technique in Petroleum industry? Answer. Artificial lift is a means of overcoming bottomhole pressure so that a well can

More information

ADJUSTABLE PIPING SUPPORT PRODUCT BROCHURE

ADJUSTABLE PIPING SUPPORT PRODUCT BROCHURE ADJUSTABLE PIPING SUPPORT PRODUCT BROCHURE OVERVIEW REVOLUTIONARY VERSATILE EFFICIENT The Roof Top Blox is a revolutionary roof top support block system that works with height extension rods, securing

More information

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain

More information

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians Data 924-2 7/12/05 EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians Features Complete sample-conditioning

More information

ADJUSTABLE PIPING SUPPORT PRODUCT BROCHURE

ADJUSTABLE PIPING SUPPORT PRODUCT BROCHURE ADJUSTABLE PIPING SUPPORT PRODUCT BROCHURE OVERVIEW REVOLUTIONARY VERSATILE EFFICIENT The Roof Top Blox is a revolutionary roof top support block system that works with height extension rods, securing

More information

- Tensile strength of 50,000 psi per ASTM D-638 or 345 Mpa - Notched Izod impact strength of 35 ft-lb/in per ASTM D-256 or 1868 J/M are achieved.

- Tensile strength of 50,000 psi per ASTM D-638 or 345 Mpa - Notched Izod impact strength of 35 ft-lb/in per ASTM D-256 or 1868 J/M are achieved. PureFlex is a world leading manufacturer of high performance Fluoropolymer and Composite products and technologies. We specialize in the manufacturing of fluid handling and sealing products specifically

More information

SP Standard Profile. Flanged to Duct Install Type THERMAL BREAKS OPPOSED ACTION PARALLEL ACTION. T.A. Morrison & Co. Inc.

SP Standard Profile. Flanged to Duct Install Type THERMAL BREAKS OPPOSED ACTION PARALLEL ACTION.  T.A. Morrison & Co. Inc. 1 SUBMITTAL DATA Series 9000 BF Thermally Insulated Damper with Thermally Broken Frames & Blades SP Standard Profile Flanged to Duct Install Type THERMAL BREAKS OPPOSED frame is 4 (101.6 mm) deep x 1 (25.4

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC PIPES AND TUBES

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC PIPES AND TUBES SECTION 23 20 00 - HVAC PIPES AND TUBES PART 1 - GENERAL 1.1 SUMMARY: A. Section includes pipe and pipe fittings for: heating water, chilled water, steam and steam condensate, condenser water, glycol,

More information

IMI Annual Meeting Steve Young Territory Sales Engineer

IMI Annual Meeting Steve Young Territory Sales Engineer IMI Annual Meeting Steve Young Territory Sales Engineer Steve.Young@Henkel.com 317.832.9264 Mining Process Basic Mining Flow 1) Extraction 2) Crushing 3) Milling 5) Hydrocyclone 8) Filtering 4) Screening

More information

Measuring Air Velocity - presented by Lonnie Glen, Kice Industries 2/28/2018. (and why it is important) Applications for Air

Measuring Air Velocity - presented by Lonnie Glen, Kice Industries 2/28/2018. (and why it is important) Applications for Air (and why it is important) Wednesday, February 28, 2018 Presented by Lonnie Glen, Kice Technical Sales and Quickship Manager Applications for Air Air Activated Processing Grinders Granulators Hammermills

More information

Piedmont Chapter 14, Vibration Institute Meeting December 5, Midlands Technical College West Columbia, SC

Piedmont Chapter 14, Vibration Institute Meeting December 5, Midlands Technical College West Columbia, SC Piedmont Chapter 14, Vibration Institute Meeting December 5, 2008 Midlands Technical College West Columbia, SC Introduction and Timing Jeremiah JB Bacon C.L.S. PetroLiance, LLC Presentation should take

More information

Light Stainless Flexible Liner

Light Stainless Flexible Liner Light Stainless Flexible Liner Dalsin Line light flexible liner is listed for chimney relining and is suitable for wood, pellet, gas, oil, and coal applications. This liner is manufactured using.006 thick

More information

Radon Vent Pipe System. Labeling Performance Indicators

Radon Vent Pipe System. Labeling Performance Indicators Section 6 Radon Vent Pipe Labeling Performance Indicators Radon Vent Pipe System Connected after sub-grade system installed Pipe cannot be trapped Provide space in chases Support at each floor level Discharge

More information

Technical Bulletin No. MK3176. PREPARED: July, 2010

Technical Bulletin No. MK3176. PREPARED: July, 2010 Geoprobe DT45 Dual Tube Sampling System Standard Operating Procedure Technical Bulletin No. MK3176 PREPARED: July, 2010 A. B. C. D. E. A. Assembled outer casing with sample sheath and liner driven to collect

More information

LOCK N SAFE LUMBER SORTER BIN RESTRAINT SYSTEMS. OPERATING & MAINTENANCE MANUAL Version MT. LNS Services A Division of Lexspan LP

LOCK N SAFE LUMBER SORTER BIN RESTRAINT SYSTEMS. OPERATING & MAINTENANCE MANUAL Version MT. LNS Services A Division of Lexspan LP LOCK N SAFE LUMBER SORTER BIN RESTRAINT SYSTEMS OPERATING & MAINTENANCE MANUAL Version 1.5 - MT LNS Services A Division of Lexspan LP 3111 Norland Avenue Burnaby, British Columbia Canada V5B 3A9 Phone:

More information

RADON ABATEMENT FROM THE GROUND UP

RADON ABATEMENT FROM THE GROUND UP RADON ABATEMENT FROM THE GROUND UP The solution for a dry, comfortable, and durable basement! CLOSED-CELL 2018 Demilec, 3315 E. Division St., Arlington, TX 76011 Phone: 817.640.4900 Fax: 817.633.2000 Info@Demilec.com

More information

Making the Right Filter Decisions for Landscape Irrigation

Making the Right Filter Decisions for Landscape Irrigation Making the Right Filter Decisions for Landscape Irrigation Reid Garner, CLIA, CID LAKOS Separators and Filtration Solutions, rgarner@lakos.com Abstract. In today s rapidly changing landscape irrigation

More information

TILE ROOF INSTALLATION MANUAL ADDENDUM

TILE ROOF INSTALLATION MANUAL ADDENDUM Distributed and serviced in the USA by Hot Sun Industries Inc 1440 N. Benson Ave Unit D Upland CA 91786 858-683 0800 e-mail: ken@h2otsun.com web site: http://www.h2otsun.com TILE ROOF INSTALLATION MANUAL

More information

Straightway Valves. Sec 2: Products. Dia-Flo Diaphragm Valves /15

Straightway Valves. Sec 2: Products. Dia-Flo Diaphragm Valves /15 Features and Benefits Ideal for slurry, abrasive and corrosive applications, the Dia-Flo Straightway Diaphragm Valve provides the following benefits: Slurry Applications Due to the streamlined fluidpassage,

More information

Standard-Duty and Heavy-Duty Tube and Pipe Clamps

Standard-Duty and Heavy-Duty Tube and Pipe Clamps Standard-Duty and Heavy-Duty Tube and Pipe Clamps Table Of Contents Evolution of Clamps... 2 Tubing vs. Piping Difference/Comparison... 3 Features/Benefits of Clamps...4-5 Standard-Duty (Light-Duty) Clamps...6-7

More information

CF100 BAND SCREENS REDUCE MAINTENANCE COSTS & DOWNTIME... INCREASE CAPTURE RATIO & EFFICIENCY

CF100 BAND SCREENS REDUCE MAINTENANCE COSTS & DOWNTIME... INCREASE CAPTURE RATIO & EFFICIENCY MUNICIPAL WASTEWATER INLET SCREENS REDUCE MAINTENANCE COSTS & DOWNTIME... INCREASE CAPTURE RATIO & EFFICIENCY Excellent pretreatment for MBR Zero carry over sealing independently proven to remove 90% of

More information

Cast Iron Sluice Gates Rugged Dependability in Demanding Applications

Cast Iron Sluice Gates Rugged Dependability in Demanding Applications Cast Iron Sluice Gates Rugged Dependability in Demanding Applications A Proud Tradition Since 1840, the team at Rodney Hunt has pioneered safe and reliable flow control systems to help communities and

More information

Lab #3 Conservation Equations and the Hydraulic Jump CEE 331 Fall 2004

Lab #3 Conservation Equations and the Hydraulic Jump CEE 331 Fall 2004 CEE 33 Lab 3 Page of 8 Lab #3 Conservation Equations and the Hydraulic Jump CEE 33 Fall 004 Safety The major safety hazard in this laboratory is a shock hazard. Given that you will be working with water

More information

Standard and Low-Flow 100 PLUS Powder Feed Pumps

Standard and Low-Flow 100 PLUS Powder Feed Pumps Instruction Sheet P/N 036G Standard and Low-Flow 00 PLUS Powder Feed Pumps Introduction Standard and low-flow 00 PLUS powder feed pumps are used to pump organic and metallic powder coatings to powder spray

More information

SUMP / EFFLUENT PUMPS ARE SINGLE PHASE WITH PIGGYBACK FLOAT SWITCH. Max. Flow 44. Max. Head 20. Voltage 115

SUMP / EFFLUENT PUMPS ARE SINGLE PHASE WITH PIGGYBACK FLOAT SWITCH. Max. Flow 44. Max. Head 20. Voltage 115 SUMP / EFFLUENT PUMPS ARE SINGLE PHASE WITH PIGGYBACK FLOAT SWITCH PL-CPSE3A 1/3 44 0 1½ NPT EFFLUENT PUMPS ARE SINGLE PHASE WITH PIGGYBACK FLOAT SWITCH PL-CPE4A-1 PL-CPE5A-1 PL-CPEH5A1 PL-CPSTEP51A PL-CPSTEP10A

More information

NEOTECHA NXR PFA LINED BALL VALVES

NEOTECHA NXR PFA LINED BALL VALVES These PFA lined ball valves are used in a wide variety of applications in many industries FEATURES GENERAL APPLICATION The valves are ideally suited for corrosive applications, requiring reliable performance,

More information

Instructions for 12 and 15 IGT systems (12 pictured)

Instructions for 12 and 15 IGT systems (12 pictured) Instructions for 12 and 15 IGT systems (12 pictured) Step 1: IGT Site Preparation Site Location Several factors must be considered when choosing the site for your new In-Ground Trampoline (IGT) system.

More information

The Unique Accelabar Flow Meter

The Unique Accelabar Flow Meter The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.

More information

Glossary Irrigation Terminology

Glossary Irrigation Terminology Glossary Irrigation Terminology ANGLE VALVE A valve configured so its outlet is oriented 90 from its inlet. In irrigation, these valves are generally installed with the inlet at the bottom of the valve.

More information

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION SECTION 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 - GENERAL 1.1 SUMMARY A. This section supplements all sections in this division, including pipe, fittings, valves, and connections for sprinkler

More information

DURA-BLOK Rooftop Supports

DURA-BLOK Rooftop Supports Cooper B-Line s new line of DURA-BLOK products gives you a versatile and long-term solution for all your roof top support needs. Designed with flexibility in mind, Dura-Blok is ideal for roof top support

More information

Stainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities.

Stainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities. Stainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities. Whether it is new construction, renovation or operation,

More information

Production. 33

Production.   33 www.upstreampumping.com 33 A solar injection powered system installed at a wellhead site. Diaphragm Pumps Enhance Chemical Injection Systems During EOR Duncan McFarland, Ferguson Beauregard, & Sudip Sarker,

More information

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE SECTION 13 34 00 METAL SHADE STRUCTURE PART 1 - GENERAL 1.01 STRUCTURE TYPE A. Structure shall be free standing rigid frame and gable roof with slopes as indicated. Structure shall also include foundation,

More information

testo 335 New measurement engineering for monitoring emissions

testo 335 New measurement engineering for monitoring emissions 8 testo 335 New engineering for monitoring emissions How many ppm NO are there really? Knut Hoyer, Head of Product Development Gas How sure can you really be that your analyzer measures exactly what it

More information

This is more than providing you with containers This is a relationship. We re here for you. We built it to last. We mean it. Here s your guarantee.

This is more than providing you with containers This is a relationship. We re here for you. We built it to last. We mean it. Here s your guarantee. This is more than providing you with containers This is a relationship Remcon Plastics has been creating high-quality, durable rotomolded containers for more than 30 years. We value our customers and always

More information

STAR Downhole Tubing (Aliphatic Amine Cured Epoxy - Product Data)

STAR Downhole Tubing (Aliphatic Amine Cured Epoxy - Product Data) STAR Downhole Tubing (Aliphatic Amine Cured Epoxy - Product Data) Product Description Pressure - Up to 4000 psi (27,6 MPa) Resin System - Aliphatic Amine Cured Epoxy Reinforcement - Premium Fiberglass

More information

This presentation covers process steam energy reduction projects supported by the Ameren Illinois ActOnEnergy program.

This presentation covers process steam energy reduction projects supported by the Ameren Illinois ActOnEnergy program. This presentation covers process steam energy reduction projects supported by the Ameren Illinois ActOnEnergy program. 1 2 Before we get started, here are four questions to find out what you already know

More information

AUTOMATIC INDUSTRIAL SAMPLING

AUTOMATIC INDUSTRIAL SAMPLING MATERIAL SAMPLING AUTOMATIC INDUSTRIAL SAMPLING PROVEN & DEPENDABLE AUTOMATIC INDUSTRIAL SAMPLING COLLECTION SYSTEMS With an automated collection system such as the Rotating Indexing Cabinet, you can receive

More information

Product Bulletin 2K-3.2. stamixco. mix it up..

Product Bulletin 2K-3.2. stamixco. mix it up.. stamixco Product Bulletin 2K-3.2 mix it up.. 2-Component Resin Mixing Technology Plastic Disposable & Metal Static Mixers for Mixing Viscous Materials 2 Introduction For more than 40 years, static mixers

More information

Collectors. Water Treatment & Chemical Processing

Collectors. Water Treatment & Chemical Processing Water Treatment & Chemical Processing Collectors Screen Services Specialty screens and equipment for industrial, petrochemical, mining, and water treatment applications Page 2 Collector/Distributors fabricated

More information

INSTRUCTION MANUAL.

INSTRUCTION MANUAL. INSTRUCTION MANUAL www.waterscapesinternational.com TABLE OF CONTENTS Product Specifications Page 2 WATER GARDENS Determining Pond Volume Page 3 Determining Surface Area Page 3 Streambed Construction Page

More information

450 and 550 Series Pressure/Vacuum Relief Valve (ATEX Approved)

450 and 550 Series Pressure/Vacuum Relief Valve (ATEX Approved) Instruction Manual 450 and 550 Series March 2015 450 and 550 Series Pressure/Vacuum Relief Valve (ATEX Approved) Table of Contents Introduction...1 Specifications...2 Principle of Operation...4 Installation...4

More information

INSTALLATION GUIDE. Model #PP2 Pumpout Port Kit For Use with Grease Interceptors Models GB-50, GB-75 and GB-250. Contents

INSTALLATION GUIDE. Model #PP2 Pumpout Port Kit For Use with Grease Interceptors Models GB-50, GB-75 and GB-250. Contents INSTALLATION GUIDE Model #PP2 Pumpout Port Kit For Use with Grease s Models GB-50, GB-75 and GB-250 Contents Special Precautions............................................ 2 Getting to Know the PP2........................................

More information

University of Delaware

University of Delaware University Contact: Energy & Engineering Group (302) 831-1744 SECTION 22 13 00 _SANITARY SEWER PIPING SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Sanitary sewer piping buried 2. Sanitary

More information

YARWAY HANCOCK CONTINUOUS BLOWDOWN GLOBE VALVE SERIES 5505

YARWAY HANCOCK CONTINUOUS BLOWDOWN GLOBE VALVE SERIES 5505 Advanced construction features of this high pressure drop angle globe valve provide quality and long service life. FEATURES GENERAL APPLICATION In addition to continuous blowdown service, the Yarway high

More information

BIO GT Series. Water Treatment Systems for Golf/Turf Maintenance Facilities

BIO GT Series. Water Treatment Systems for Golf/Turf Maintenance Facilities Water Treatment Systems for Golf/Turf Maintenance Facilities SCE Water Treatment Systems provide a better tomorrow by protecting our environment today. A Biological water treatment system can save thousands

More information

Rosemount Annubar Flowmeter Series. The Value of Innovation, Realized

Rosemount Annubar Flowmeter Series. The Value of Innovation, Realized Rosemount Annubar Flowmeter Series The Value of Innovation, Realized Insertion Technology, Simplified. Averaging Pitot Tube (APT) technology reduces the total cost of ownership of the flow measurement

More information

Liner Replacement Instructions:

Liner Replacement Instructions: Liner Replacement Instructions: Before beginning the replacement procedure... Be sure to disconnect electrical service to all of your electrical components of the pool. Use extreme caution when working

More information

sprinkler technology Water Application Solutions for Center Pivot Irrigation Save water, save energy and do a better job of irrigating.

sprinkler technology Water Application Solutions for Center Pivot Irrigation Save water, save energy and do a better job of irrigating. nelson irrigation corporation sprinkler technology Product Update 0308 Water Application Solutions for Center Pivot Irrigation THE VALUE OF A NEW SPRINKLER PACKAGE IS GREATER THAN EVER! New sprinkler technology

More information

Case Study: Parkson DynaSand D2 Filtration and Compliance Jessy Matthew John, The Probst Group

Case Study: Parkson DynaSand D2 Filtration and Compliance Jessy Matthew John, The Probst Group Case Study: Parkson DynaSand D2 Filtration and Compliance Jessy Matthew John, The Probst Group Primarily we will be discussing DynaSand D2 Sand Filters and performance, a method of advanced tertiary filtration.

More information

Flowserve Anchor Darling ½ 2 Small Valve Product Line

Flowserve Anchor Darling ½ 2 Small Valve Product Line Flowserve Anchor Darling ½ 2 Small Valve Product Line Problem Low cost, small-bore valves that have a very high life-cycle cost due to performance problems such as packing and seat leakage. Solution Flowserve

More information

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED Chapter 17 Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.1.1 Applicability The regulations in this chapter apply to any private potable water supply system where plumbing fixtures are

More information

Chemical Injection. Systems and Equipment for Oil and Natural Gas

Chemical Injection. Systems and Equipment for Oil and Natural Gas Chemical Injection Systems and Equipment for Oil and Natural Gas Chemical Injection Product Scope Solar Powered Chemical Injection Systems Electric Chemical Injection Pumps Hazardous Location Pumps Pump

More information