LSA 42.3 Low Voltage Alternators - 4 pole

Size: px
Start display at page:

Download "LSA 42.3 Low Voltage Alternators - 4 pole"

Transcription

1 LSA 42.3 Low Voltage Alternators - 4 pole 2 to 60 kva - 0 Hz / 31. to 7 kva - 60 Hz Electrical and mechanical data

2 Specially adapted to applications The LSA 42.3 alternator is designed to be suitable for typical generator applications, such as: backup, marine applications, rental, telecommunications, etc. Compliant with international standards The LSA 42.3 alternator conforms to the main international standards and regulations: - IEC 60034, NEMA MG , ISO 28-3, CSA C22.2 n 0-14, UL 1446 (UL 04 on request), marine regulations, etc. It can be integrated into a CE marked generator. The LSA 42.3 is designed, manufactured and marketed in an ISO 01 and ISO environment. Top of the range electrical performance Class H insulation. Standard 12 wire re-connectable winding, 2/3 pitch, type no. 6 Voltage range: - 0 Hz: 2 V V and 3 V - 41 V (440 V) - 60 Hz: 8 V V and 3 V - 4 V High efficiency and motor starting capacity Other voltages are possible with optional adapted windings: - 0 Hz: 440 V (no. 7), 00 V (no. 9), 6 V (n ) - 60 Hz: 3 V and 416 V (no. 8), 600 V (no. 9) R 791 interference suppression conforming to standard EN , EN , EN 011 group 1 class B standard for European zone (CE marking) Reinforced mechanical structure using finite element modelling Compact rigid assembly to better withstand generator vibrations Steel frame Aluminium flanges and shields Two-bearing and single-bearing versions designed to be suitable for commercially-available heat engines Half-key balancing two bearing Permanently greased bearings ( 000h) Direction of rotation : clockwise and anti-clockwise (without derating) Excitation and regulation system suited to the application Excitation system Regulation options Voltage regulator PMG Current transformer for paralleling Mains paralleling 3-phase sensing 3-phase sensing for mains paralleling unbalanced Remote voltage potentiometer R2 Std R438 - Std Std C.T. R726* R731* R734* R40* Option Option Option C.T. R726* R731* R734* DC* Option Option Option C.T. included included contacter factory * Steel terminal box mounting only : Possible mounting Compact and design terminal box Easy access to the AVR (lid) and to the connections 8 way terminal block for reconnecting the voltage Predrilled holes for cable gland Steel terminal box in option Protection system suited to the environment The LSA 42.3 is IP 23 Standard winding protection for clean environments with relative humidity, including indoor marine environments Options: - Filters on air inlet : derating % - Filters on air inlet and air outlet (IP 44) : derating % - Winding protection for harsh environments and relative humidity greater than - Space heaters - Thermal protection for stator windings - Height fixing : H = 22 mm (option) with the order 2 Electric Power Generation

3 General characteristics Insulation class H Excitation system or PMG Winding pitch 2/3 (wdg 6) AVR type R 2 R 438 Number of wires 12 Voltage regulation (*) ± 0. % ± 0. % Protection IP 23 Short-circuit current - 0% (3 IN): s Altitude 00 m Total Harmonic Distortion THD (**) in no-load... : < 2% Overspeed 220 min -1 Total Harmonic Distortion THD (**) on linear load : < 4% Air flow 0.m 3 /s, 0 Hz m 3 /s, 60 Hz Waveform: NEMA = TIF (**) < 0 (*) Steady state. (**) Total harmonic distortion between phases, no-load or on-load (non-distorting). Ratings 0 Hz R.P.M. kva / kw - P.F. = 0.8 Duty/T C Continuous duty/40 C Continuous duty/40 C Stand-by/40 C Stand-by/27 C Class/T K H/12 K F/ K H/10 K H/163 K Phase 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. Y 3V 400V 41V 440V 3V 400V 41V 440V 3V 400V 41V 440V 3V 400V 41V 440V 2V 2V 240V 2V 2V 2V 240V 2V 2V 2V 240V 2V 2V 2V 240V 2V YY 2V 2V 2V 2V 42.3 VS1 kva kw VS2 kva kw VS3 kva kw S4 kva kw S kva kw kva kw kva kw kva kw Ratings 60 Hz - 10 R.P.M. kva / kw - P.F. = 0.8 Duty/T C Continuous duty/40 C Continuous duty/40 C Stand-by/40 C Stand-by/27 C Class/T K H/12 K F/ K H/10 K H/163 K Phase 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. Y 3V 416V 440V 4V 3V 416V 440V 4V 3V 416V 440V 4V 3V 416V 440V 4V 2V 240V 240V 2V 240V 240V 2V 240V 240V 2V 240V 240V YY 8V 2V 240V 8V 2V 240V 8V 2V 240V 8V 2V 240V 42.3 VS1 kva , , ,8 kw , , , VS2 kva , , ,1 kw , , , VS3 kva , , ,1 kw , , , S4 kva , , ,6 kw , , , S kva , , ,4 kw , , , kva , , ,0 kw , , , kva , , ,3 kw , , , kva , , ,9 kw , , ,3 Electric Power Generation 3

4 Efficiencies 400 V - 0 Hz ( P.F.: 0.8) (... P.F.: 1 ) LSA 42.3 VS LSA 42.3 S kva kVA 88.2 LSA 42.3 VS LSA kva kVA LSA 42.3 VS LSA kva kVA LSA 42.3 S LSA kva kVA Reactances (%). Time constants (ms) - Class H / 400 V VS1 VS2 VS3 S4 S Kcc Short-circuit ratio Xd Direct-axis synchro. reactance unsaturated Xq Quadrature-axis synchro. reactance unsaturated T do No-load transient time constant X d Direct-axis transient reactance saturated T d Short-circuit transient time constant X d Direct-axis subtransient reactance saturated T d Subtransient time constant X q Quadrature-axis subtransient reactance saturated Xo Zero sequence reactance unsaturated X2 Negative sequence reactance saturated Ta Armature time constant Other class H/400 V data io (A) No-load excitation current (/) 0./0. 0.2/ / / / / / /0.77 ic (A) On-load excitation current (/) 1.74/ / / / / / / /3.13 uc (V) On-load excitation voltage (/) 29.6/ / / / / /18.8.6/ /21.2 ms Response time ( U = % transient) < 00ms < 00ms < 00ms < 00ms < 00ms < 00ms < 00ms < 00ms kva Start ( U = % cont. or ( U = % trans.) kva Start ( U = % cont. or ( U = % trans.) % Transient U (on-load 4/4) - P.F.: 0.8 LAG % Transient U (on-load 4/4) - P.F.: 0.8 LAG W No-load losses W Heat dissipation Electric Power Generation

5 Transient voltage variation 400V - 0 Hz % 2 Phase loading () VS1 VS2 VS3 S4 S % 2 Phase loading ( & PMG) VS1 VS2 VS3 S4 S kva kva Load shedding () Load shedding ( & PMG) VS1 VS2 VS3 S4 S VS1 VS2 VS3 S4 S Voltage rise Voltage rise kva kva kva at PFØ 0.8 Motor starting () Motor starting ( & PMG) VS1 VS2 VS3 S4 S VS1 VS2 VS3 S4 S 13% kVA 4.8 locked rotor kva at PF Ø kVA locked rotor kva at PF Ø 0.6 1) For a starting P.F. other than 0.6, the starting kva must be multiplied by K = Sine P.F. / 0.8 Calculation example for a different P.F. other than 0.6: Starter motor kva calculated at 0.4 P.F. = 40 kva > Sin P.F. 0.4 = > K = 1.14 > kva corrected = 4.8 kva > Voltage dip corresponding to = 13%. 2) For voltages other than 400V (Y), 2V ( ) at 0 Hz, then kva must be multiplied by (400/U) 2 or (2/U) 2. Electric Power Generation

6 Efficiencies 4 V - 60 Hz ( P.F.: 0.8) (... P.F.: 1 ) LSA 42.3 VS kVA LSA 42.3 VS LSA 42.3 S kva LSA kVA kva LSA 42.3 VS LSA kVA kva LSA 42.3 S LSA kVA kva Reactances (%). Time constants (ms) - Class H / 4 V VS1 VS2 VS3 S4 S Kcc Short-circuit ratio Xd Direct-axis synchro. reactance unsaturated Xq Quadrature-axis synchro. reactance unsaturated T do No-load transient time constant X d Direct-axis transient reactance saturated T d Short-circuit transient time constant X d Direct-axis subtransient reactance saturated T d Subtransient time constant X q Quadrature-axis subtransient reactance saturated Xo Zero sequence reactance unsaturated X2 Negative sequence reactance saturated Ta Armature time constant Other class H/4 V data io (A) No-load excitation current (/) 0./0. 0.2/ / / / / / /0.77 ic (A) On-load excitation current (/) 1.76/ / / / / / / /3.06 uc (V) On-load excitation voltage (/).2/ /19.3/ / / /18.8.9/ /21.1 ms Response time ( U = % transient) < 00ms < 00ms < 00ms < 00ms < 00ms < 00ms < 00ms < 00ms kva Start ( U = % cont. or ( U = % trans.) kva Start ( U = % cont. or ( U = % trans.) % Transient U (on-load 4/4) - P.F.: 0.8 LAG % Transient U (on-load 4/4) - P.F.: 0.8 LAG W No-load losses W Heat dissipation Electric Power Generation

7 Transient voltage variation 4V - 60 Hz Phase loading () Phase loading ( & PMG) % 2 VS1 VS2 VS3 S4 S % 2 VS1 VS2 VS3 S4 S kva kva Load shedding () Load shedding ( & PMG) VS1 VS2 VS3 VS1 VS2 VS3 S4 S S4 S Voltage rise Voltage rise kva kva Motor starting () Motor starting ( & PMG) VS1 VS2 VS3 S4 S VS1 VS2 VS3 S4 S 12% kVA 4.8 locked rotor kva at PF Ø kVA locked rotor kva at PF Ø 0.6 1) For a starting P.F. other than 0.6, the starting kva must be multiplied by K = Sine P.F. / 0.8 Calculation example for a different P.F. other than 0.6: Starter motor kva calculated at 0.4 P.F. = 40 kva > Sin P.F. 0.4 = > K = 1.14 > kva corrected = 4.8 kva > Voltage dip corresponding to = 12%. 2) For voltages other than 4V (Y), 277V ( ), 240V (YY) at 60 Hz, then kva must be multiplied by (4/U) 2 or (277/U) 2 or (240/U) 2. Electric Power Generation 7

8 3-phase short-circuit curves at no load and rated speed (star connection Y) LSA 423 VS LSA 423 VS LSA 423 VS LSA 423 S Influence due to connection Curves shown are for star (Y) connection. For other connections, use the following multiplication factors: - Series delta : current value x Parallel star : current value x 2 8 Electric Power Generation

9 3-phase short-circuit curves at no load and rated speed (star connection Y) 000 LSA 423 S LSA LSA LSA Influence due to short-circuit Curves are based on a three-phase short-circuit. For other types of short-circuit, use the following multiplication factors. 3-phase 2-phase L/L 1-phase L/N Instantaneous (max.) Continuous Maximum duration (/PMG) sec. sec. 2 sec. Electric Power Generation 9

10 Single bearing dimensions LSA S.A.E. 3 L Ø Ø N AH Ø BX LB Ø P Ø N AH Ø BX Xg 3 2 L LB Optional PMG Ø 23 XBG Ø 11 holes equid. over Ø M 4 Access to terminals Cable outlet X Ø Y holes equid. over Ø U 1 Ø 64 Access to AVR H 264 (270.:) +1-3 AIR OUTLET T LA C AIR OUTLET T LA C B INLET Optional H = 22 A2 A1 Dimensions (mm) and weight (kg) H = 1 (Standard) H = 22 (Option) Coupling L LB Xg Masse (kg) C B A1 A2 C B A1 A2 Flange LSA 42.3 VS Flex plate LSA 42.3 VS /2 x x - LSA 42.3 VS x x x LSA 42.3 S x x LSA 42.3 S /2 - x x LSA LSA LSA Flange (mm) Flex plate (mm) S.A.E. P N M XBG T LA S.A.E. BX U X Y AH / / Xr Torsional analysis data Ø 18 Ø 60 Lr Ø 41 Ø Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg), Moment of inertia: J (kgm 2 ): (4J = MD 2 ) Flex plate S.A.E. 7 1/2 Flex plate S.A.E. 8 Flex plate S.A.E. Flex plate S.A.E. 11 1/2 Type Xr Lr M J Xr Lr M J Xr Lr M J Xr Lr M J LSA 42.3 VS LSA 42.3 VS LSA 42.3 VS LSA 42.3 S LSA 42.3 S LSA LSA LSA NOTE : Dimensions are for information only and may be subject to modifications. Contractual 2D drawings can be downloaded from the Leroy- Somer site, 3D drawing files are available upon request. The torsional analysis of the transmission is imperative. All values are available upon request. Electric Power Generation

11 Two bearing dimensions Ø P 1 M16 hole 36 depth Ø N Ø 48 k6 LB 82 Xg AIR OUTLET C 172 L 14 AIR INLET 137 4x2 M holes on Ø M to 4 Access to terminals Access to the AVR Optional PMG Cable outlet Ø M holes to unusable M12 hole 18 depth (270.:) Dimensions (mm) and weight (kg) Type L LB N M P C Xg Weight (kg) LSA 42.3 VS LSA 42.3 VS LSA 42.3 VS LSA 42.3 S LSA 42.3 S LSA LSA LSA Torsional analysis data Xr Ø 48 Ø 0 Ø 60 Lr Ø 41 Ø Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg), Moment of inertia: J (kgm 2 ): (4J = MD 2 ) Type Xr Lr M J LSA 42.3 VS LSA 42.3 VS LSA 42.3 VS LSA 42.3 S LSA 42.3 S LSA LSA LSA NOTE : Dimensions are for information only and may be subject to modifications. Contractual 2D drawings can be downloaded from the Leroy- Somer site, 3D drawing files are available upon request. The torsional analysis of the transmission is imperative. All values are available upon request. Electric Power Generation 11

12 Linkedin.com/company/Leroy-Somer Twitter.com/Leroy_Somer_en Facebook.com/LeroySomer.Nidec.en YouTube.com/LeroySomerOfficiel Nidec 17. The information contained in this brochure is for guidance only and does not form part of any contract. The accuracy cannot be guaranteed as Nidec have an ongoing process of development and reserve the right to change the specification of their products without notice. Moteurs Leroy-Somer SAS. Siège : Bd Marcellin Leroy, CS 01, 1691 Angoulême Cedex 9, France. Capital social : , RCS Angoulême en / j

LSA 51.2 Low Voltage Alternators - 4 pole

LSA 51.2 Low Voltage Alternators - 4 pole LSA 1.2 Low Voltage Alternators - 4 pole 186 to 2 kva - Hz / 223 to 3 kva - 6 Hz Electrical and mechanical data Specially adapted to applications The LSA 1.2 alternator is designed to be suitable for typical

More information

Low Voltage alternators - 4 pole LSA 42.3

Low Voltage alternators - 4 pole LSA 42.3 Low Voltage alternators - 4 pole LSA 42.3 2 to 60 kva - 0 Hz / 31. to 7 kva - 60 Hz Electrical and mechanical data 42en - 12.02 / c SPECIALLY ADAPTED TO APPLICATIONS The LSA 42.3 alternator is designed

More information

LSA 47.2 Low Voltage Alternators - 4 pole

LSA 47.2 Low Voltage Alternators - 4 pole LSA 47.2 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Electrical and mechanical data LSA 47.2-36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Specially adapted to applications The LSA 47.2 alternator is designed to be

More information

Low Voltage Alternators - 4 pole LSA 46.2

Low Voltage Alternators - 4 pole LSA 46.2 LSA 46.2 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz Electrical and mechanical data LSA 46.2-18 to 31 kva - Hz / 228 to 381 kva - 6 Hz Specially adapted to applications The LSA 46.2 alternator is designed

More information

Low Voltage Alternators - 4 pole LSA 46.3

Low Voltage Alternators - 4 pole LSA 46.3 LSA 46.3 180 to 365 kva - 50 Hz / 225 to 435 kva - 60 Hz Electrical and mechanical data Specially adapted to applications The LSA 46.3 alternator is designed to be suitable for typical generator applications,

More information

LSA 53.2 Low Voltage Alternator - 4 pole

LSA 53.2 Low Voltage Alternator - 4 pole LSA 53.2 Low Voltage Alternator - 4 pole 400V - 50 Hz / 480V - 60 Hz Electrical and mechanical data Specially adapted to applications The LSA 53.2 alternators are designed to be suitable for typical generator

More information

3867 en / f. Alternators. LSA Pole Electrical and mechanical data

3867 en / f. Alternators. LSA Pole Electrical and mechanical data 3867 en - 21.4 / f 66... 1 kva - Hz 7... 12 kva - 6 Hz Alternators LSA 49.1-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 49.1 alternator is designed to be suitable for

More information

3867 en / a

3867 en / a 3867 en - 9.24 / a Alternators LSA 49.1-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 49.1 alternator is designed to be suitable for typical generator applications, such

More information

3820 en / c

3820 en / c 38 en -.6 / c Alternators LSA 44.2-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 44.2 alternator is designed to be suitable for typical generator applications, such as:

More information

Alternators single phase dedicated - 4 Pole LSA 43.2 / LSA 44.2

Alternators single phase dedicated - 4 Pole LSA 43.2 / LSA 44.2 Alternators single phase dedicated - 4 Pole LSA 43.2 / LSA 44.2 5 to 135 kva Electrical and mechanical data 3542 en - 12.08 / f LSA 43.2 / 44.2-4 Pole SPECIALLY ADAPTED FOR SINGLE PHASE Dedicated single

More information

3363 en / e

3363 en / e 3363 en - 03.2005 / e alternators 4 Pole range : 5-2700 kva General features and ratings ALTERNATORS Summary Page 1 - RATING DEFINITION... 3 2 - INSULATION CLASS AND TEMPERATURE RISE... 3 3 - DERATING...

More information

LSA Rating Table Low Voltage Alternators - 4 pole

LSA Rating Table Low Voltage Alternators - 4 pole LSA Rating Table Low Voltage Alternators - 10 to 3300 kva - 50 Hz / 12.5 to 3900 kva - 60 Hz General features and ratings Summary 1 - RATING DEFINITION... 3 2 - INSULATION CLASS AND TEMPERATURE RISE...

More information

ALTERNATOR. LSA 36 - single-phase to 11.5 kva

ALTERNATOR. LSA 36 - single-phase to 11.5 kva 3692 en - 2009.07 / f ALTERNATOR LSA 36 - single-phase - 3.5 to 11.5 kva LSA 36 ALTERNATOR Developed using special modelling software to give optimised electrical performance Designed to supply power to

More information

3456 en / c. 1 to 20 MW Land and offshore applications

3456 en / c. 1 to 20 MW Land and offshore applications 3456 en - 12.2005 / c 1 to 20 MW Land and offshore applications POWER ALTERNATORS Generating Progress Gas or steam turbine application There is currently an enormous increase in energy requirements throughout

More information

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form)

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) Attachment 2 Transmission Provider: Bluestem Electric Cooperative, Inc. Designated Contact Person: Kevin Heptig Address: P.O. Box 5, Wamego, Kansas

More information

Environmental Product Declaration FLSES. 3-phase induction motors with cast iron frame

Environmental Product Declaration FLSES. 3-phase induction motors with cast iron frame FLSES 3-phase induction motors with cast iron frame INFORMATION ABOUT THE COMPANY Leroy-Somer is one of the world leaders in electromechanical and electronic drive systems and the world leader in industrial

More information

EC medium pressure axial fans.

EC medium pressure axial fans. EC medium pressure axial fans. The efficient system solution. The engineer s choice GreenTech EC technology in a new dimension. Thanks to these new new axial axial fans, fans, our our highly highly efficient

More information

Form B GENERATION INTERCONNECTION APPLICATION (Non-Inverter Based Generation and Inverter Based Generation > 25 kw)

Form B GENERATION INTERCONNECTION APPLICATION (Non-Inverter Based Generation and Inverter Based Generation > 25 kw) Form B GENERATION INTERCONNECTION APPLICATION (Non-Inverter Based Generation and Inverter Based Generation > 25 kw) Preface: This Facility Connection Standard applies to any connection to Westar Energy's

More information

Environmental Product Declaration PLSES. 3-phase induction ODP motors

Environmental Product Declaration PLSES. 3-phase induction ODP motors PLSES 3-phase induction ODP motors INFORMATION ABOUT THE COMPANY Leroy-Somer is one of the world leaders in electromechanical and electronic drive systems and the world leader in industrial alternators.

More information

Product Environnemental Profile LSES. 3-phase induction motors with aluminium frame

Product Environnemental Profile LSES. 3-phase induction motors with aluminium frame Product Environnemental Profile LSES 3-phase induction motors with aluminium frame INFORMATION ABOUT THE COMPANY Leroy-Somer is one of the world leaders in electromechanical and electronic drive systems

More information

Marine motors. 10/2 Orientation 10/2 Overview 10/3 Benefits 10/3 Application 10/3 Technical specifications 10/5 More information

Marine motors. 10/2 Orientation 10/2 Overview 10/3 Benefits 10/3 Application 10/3 Technical specifications 10/5 More information /2 Orientation /2 Overview /3 Benefits /3 Application /3 Technical specifications /5 More information /6 Type approved standard motors up to frame size 315 L /6 Overview /7 Type approved explosion-proof

More information

EC medium pressure axial fans. The efficient system solution.

EC medium pressure axial fans. The efficient system solution. EC medium pressure axial fans. The efficient system solution. GreenTech EC technology in a new dimension. Thanks to the new axial fans, our highly efficient GreenTech EC technology is now available for

More information

GARKANE ENERGY COOPERATIVE SMALL GENERATOR QUALIFIED FACILITY INTERCONNECTION APPLICATION

GARKANE ENERGY COOPERATIVE SMALL GENERATOR QUALIFIED FACILITY INTERCONNECTION APPLICATION Designated Contact Person: Mike Avant, Engineering Manager Address (for U.S. Mail Deliveries): Garkane Energy 1802 S Highway 89A Kanab, UT 84741 Telephone Number: (435) 644-5-26 E-Mail Address: mike.avant@garkane.com

More information

Interconnection Application

Interconnection Application Interconnection Application Persons interested in applying for the interconnection of a distributed energy resource to the Utility s distribution system through the Fast Track or Study Processes are to

More information

Dated: April 16, 2002

Dated: April 16, 2002 Central Hudson Gas & Electric Corporation (CHG&E) Application Process for Distributed Generators of Greater than 300 kva Connected in Parallel with the CHG&E Electrical Delivery System Dated: April 16,

More information

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches. PRESSURE SWITCHES 8D-LT Electro-mechanical pneumatic pressure switches 8D-LT x Electro-mechanical pneumatic pressure switches Page -0 Page -0-0 8D-LT G/, / NPT or flange Microswitch with gold plated contacts

More information

Generation Application Part B: Technical Form

Generation Application Part B: Technical Form Generation Connections Generation Application Part B: Technical Form For all applications with total installed generation capacity greater than 16A per phase (>4). 01 May 2018 How to fill out this application

More information

Zero cross function. DIN track mounting *2. Screw mounting

Zero cross function. DIN track mounting *2. Screw mounting Solid State Contactors for Heaters Three-phase CSM_Three-phase_DS_E_3_1 Compact, Slim-profile SSRs with Heat Sinks. Solid State Contactors for Three-phase Heaters Reduced Installation Work with DIN Track

More information

SECTION A. NEC Compliance: Comply with NEC as applicable to installation and construction of electrical power/distribution transformers.

SECTION A. NEC Compliance: Comply with NEC as applicable to installation and construction of electrical power/distribution transformers. N 16461 DRY TYPE TRANSFORMERS PART 1 - GENERAL 1.01 WORK INCLUDED: A. Copper-wound transformer optimized for light loading, meeting US Department of Energy proposed Candidate Standard Level (CSL) 3 efficiency,

More information

Unit Coolers SKB. 4 kw 30,5 kw.

Unit Coolers SKB. 4 kw 30,5 kw. Unit Coolers SKB 4 kw 30,5 kw www.friga-bohn.com SKB range unit coolers are suitable for chilling or low temperature storage applications. 24 basic models with capacities ranging from 4 to 30.5 kw. NOMENCLATURE...

More information

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.0 kw -.0 kw PHRT.00 kw -.0 kw 0.0

More information

The company 2 Our vision 3 Our mission 3 Marelli Motori Group of companies 4 Core markets 6 Our commitment to quality 8

The company 2 Our vision 3 Our mission 3 Marelli Motori Group of companies 4 Core markets 6 Our commitment to quality 8 Cogeneration Content Cogeneration Content The company 2 Our vision 3 Our mission 3 Marelli Motori Group of companies 4 Core markets 6 Our commitment to quality 8 Inspired solutions 10 No compromise on

More information

Connection of generation plant to distribution networks. Guidance on completing the application form

Connection of generation plant to distribution networks. Guidance on completing the application form Connection of generation plant to distribution networks It is possible to connect almost any generation plant to the distribution network and in order for the connection to meet the requirements of a new

More information

Power Quality Improvement in Distribution System Using Distribution Static Compensator

Power Quality Improvement in Distribution System Using Distribution Static Compensator Power Quality Improvement in Distribution System Using Distribution Static Compensator Jay Kumar Sharma 1, Om Prakash Mahela 2 and Sunil Agarwal 1 1 Department of Electrical Engineering, Apex Institute

More information

Insulated enclosure, +knockouts, RAL7032, HxWxD=500x375x225mm

Insulated enclosure, +knockouts, RAL7032, HxWxD=500x375x225mm DATASHEET - CI45E-200-RAL7032 Delivery program Insulated enclosure, +knockouts, RAL7032, HxWxD=500x375x225mm Part no. CI45E-200-RAL7032 Catalog No. 090160 EL-Nummer (Norway) 2502339 Dimensions mm Product

More information

3-Position Cylinder Lock Operator Cat. No. 800T-J41A 800 T J41 KC1 A T-XAVs 1 on white

3-Position Cylinder Lock Operator Cat. No. 800T-J41A 800 T J41 KC1 A T-XAVs 1 on white 3-Position Selector Switch Devices, Non-Illuminated (Bul. 800T only) 3-Position Cylinder Lock Operator Cat. No. 800T-J41A 800 T J41 KC1 A a b c d e f a c (cont d) e (cont d) f (cont'd) Protection Rating

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA MATERIALS MANAGEMENT TITLE DRAG LINK CHAIN FEEDERS Phone: +91 431 2574091/2574046

More information

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number PART 1 GENERAL 01 02 03 04 SCOPE Furnish and install Manual Transfer Switches (MTS) and

More information

MATERIAL AND EQUIPMENT STANDARD FOR ROTATING ELECTRICAL MACHINES DIRECT CURRENT MOTORS ORIGINAL EDITION MAY 1993

MATERIAL AND EQUIPMENT STANDARD FOR ROTATING ELECTRICAL MACHINES DIRECT CURRENT MOTORS ORIGINAL EDITION MAY 1993 IPS-M-EL-136 MATERIAL AND EQUIPMENT STANDARD FOR ROTATING ELECTRICAL MACHINES DIRECT CURRENT MOTORS ORIGINAL EDITION MAY 1993 This standard specification is reviewed and updated by the relevant technical

More information

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump Pump Specifications 450 Series 1/2 hp Submersible Sump Pump 450_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. 450-Series Dimensional

More information

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A. FAST POWER FACTOR REGULATOR Computer-14df - xx - 144a INSTRUCTION MANUAL ( M 981 611 / 00A ) (c) CIRCUTOR S.A. -------- POWER FACTOR REGULATOR COMPUTER- 14f --------- Page 2 POWER FACTOR REGULATOR COMPUTER-

More information

Applications. Capacitance Tolerance The last three digits represent significant figures. The first digit specifies the total number of digits.

Applications. Capacitance Tolerance The last three digits represent significant figures. The first digit specifies the total number of digits. AC Line EMI Suppression and RC Networks PMR205 Series Metallized Impregnated Paper, 125 VAC/250 VDC Overview Applications The PMR205 Series is constructed of multilayer metallized paper encapsulated and

More information

Equipment Specifications Low Voltage. Active Harmonic Filter

Equipment Specifications Low Voltage. Active Harmonic Filter Equipment Specifications Low Voltage Active Harmonic Filter 1.0 General Description This section contains the design standards, general equipment type and configuration, components, product description,

More information

www.eaton.eu\busbars Power Xpert XP2 Aluminium Eaton Power Xpert XP2 is a 1000 Volt totally encased, non-ventilated, low impedance sandwich construction. The range is available from 800A - 5000A with multiple

More information

Applications R46 K I P0 M

Applications R46 K I P0 M Overview The R46 Series is constructed of metallized polypropylene film encapsulated with self-extinguishing resin in a box of material that meets the requirements of UL 94 V 0. Applications For worldwide

More information

SECTION GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT

SECTION GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT SECTION 23 05 12 GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. Also delete

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Output

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 00 bar Output

More information

15 15A 20 20A 30 30A 40 40A 60 60A VAC VAC VDC 24VAC VAC. 1 Single-phase. SRH VAC Zero cross turn-on

15 15A 20 20A 30 30A 40 40A 60 60A VAC VAC VDC 24VAC VAC. 1 Single-phase. SRH VAC Zero cross turn-on Features DIN rail mount or panel mount installation Dielectric strength: 4000 VAC High heat dissipation efficiency with ceramic PCB and integrated heatsink, random turn-on models available Input Indicator

More information

SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL SPECIFICATION FOR APPROVAL Customer : Description : EST FAN (Energy Saving Technology Fan) Customer Part No. REV. : Delta Model No. REV. : 02 Sample Issue No. : Sample Issue Date : Nov. 07 2017 PLEASE

More information

MODEL 16ASX T/S - SPECIFICATION

MODEL 16ASX T/S - SPECIFICATION MODEL 16ASX T/S - SPECIFICATION 1.0 General Specifications TM There will be furnished one (1) only Grind Hog Model 16ASX T/S Comminutor as manufactured by G.E.T. Industries, Inc. Rotation shall be in a

More information

nicrom e l e c t r o n i c

nicrom e l e c t r o n i c G E N E R A L High Performance Thick Film Resistors C A T A L O G 3 Nicrom Electronic Via Roncaglia CH - 6883 Novazzano SWITZERLAND Phone : ++4 () 9 68 99 86 Fax : ++4 () 9 68 99 86 info@nicrom-electronic.com

More information

- Zone 1, 2, 21, 22 - Mechanical strength - Reliability over time - Instant, bright illumination

- Zone 1, 2, 21, 22 - Mechanical strength - Reliability over time - Instant, bright illumination SLED Painted aluminium body and cover - Zone 1, 2, 21, 22 - Mechanical strength - Reliability over time - Instant, bright illumination Tempered glass Ex e terminal board housing for fast connection Mounting

More information

15 15A 20 20A 30 30A 40 40A 60 60A. Load voltage(rated) VAC VAC VDC 24VAC VAC

15 15A 20 20A 30 30A 40 40A 60 60A. Load voltage(rated) VAC VAC VDC 24VAC VAC Single phase, Intergrated heatsink type SSR Features Superior di strength : 4,000VAC Improved reliability by maximizing heat protection efficiency with heatsink integrated design and ceramic board Various

More information

MAY-16 REV B2

MAY-16 REV B2 Product Specification 108-20025 06-MAY-16 REV B2 The product described in this document has not been fully tested to ensure conformance to the requirements outlined below. Therefore, TE Connectivity (TE)

More information

Oil & Gas Energy Solutions. Power Generation Expertise for the Oil & Gas Industry

Oil & Gas Energy Solutions. Power Generation Expertise for the Oil & Gas Industry Oil & Gas Energy Solutions Power Generation Epertise for the Oil & Gas Industry www.pssnola.com 1-800-256-4046 Power Solutions for the Oil and Gas Industry Electric Power Generation was built on the eperience

More information

Cannon Trident Connector System

Cannon Trident Connector System These are low installed cost connectors rated for up to 13 A and 250 V ac. They are typically used for circuit board and internal wiring applications. Snap Together connectors facilitate easy assembly

More information

RadiFit EC centrifugal fans. Compact, efficient, easily upgraded.

RadiFit EC centrifugal fans. Compact, efficient, easily upgraded. RadiFit EC centrifugal fans. Compact, efficient, easily upgraded. Fits, saves and makes sense! Our RadiFit range of centrifugal fans with scroll housing and backward curved blades is the new system solution

More information

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011 100 Best Efficiency Point 90 80 70 TDH (ft) 60 50 40 30 20 10 The curve reflects maximum performance characteristics without exceeding full load (Nameplate) horsepower. Operation is recommended near the

More information

G2DT Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10074SSD-1 Section: Performance Data Dated: January, 2011

G2DT Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10074SSD-1 Section: Performance Data Dated: January, 2011 100 Best Efficiency Point 90 80 70 TDH (ft) 60 50 40 30 20 10 The curve reflects maximum performance characteristics without exceeding full load (Nameplate) horsepower. Operation is recommended near the

More information

Applications PME295 R B 3470 M R30 P 295 B E 471 M 440 A. First two digits represent significant figures. Third digit specifies number of zeros.

Applications PME295 R B 3470 M R30 P 295 B E 471 M 440 A. First two digits represent significant figures. Third digit specifies number of zeros. AC Line EMI Suppression and RC Networks PME295 Series Metallized Impregnated Paper, Class Y1, 440 VAC/480 VAC Overview The PME295 Series is constructed of multilayer metallized paper encapsulated and impregnated

More information

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma -wire: 0 0 V others on request

More information

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications MGE Galaxy 5000 40/50/60/80/100/130 kva The recommended power protection for all critical applications 40-130 kva state-of-the-art threephase power protection designed to meet a wide range of requirements

More information

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202-203 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300-301 QUANTITY FOR

More information

STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017

STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017 STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017 CO-GENERTATION POWER PLANT CONCEPT For dimensioning, design

More information

Air Cooler Industry AC-MS Modular Systems

Air Cooler Industry AC-MS Modular Systems Air Cooler Industry AC-MS Modular Systems General The new AC-MS air coolers are specifically designed to meet the needs of electric power generation applications, such as Diesel or gas generators, gas

More information

Condensers & dry coolers ODIN. Excellent energy yield & sound characteristics

Condensers & dry coolers ODIN. Excellent energy yield & sound characteristics Condensers & dry coolers ODIN Excellent energy yield & sound characteristics O jççéä=áåçáå~íáçå `çåíéåíë= page Model indication................................. 2 Eurovent.......................................

More information

DRUM MOTOR 138LS 138.5Ø 0.10kW kW, with steel helical gearbox

DRUM MOTOR 138LS 138.5Ø 0.10kW kW, with steel helical gearbox 8 DRUM MOTOR DRUM MOTOR 18LS 18.5Ø 0.10kW - 1.00kW, with steel helical gearbox Product description The drum motor 18LS is a very fl exible component thanks to the wide range of powers and speeds. Characteristics

More information

Axial Fans - Basic principles. Expertise, performance, innovation

Axial Fans - Basic principles. Expertise, performance, innovation Axial Fans - Basic principles Expertise, performance, innovation Fans Motors Control electronics Appendix 15 The truly space-saving axial fans from ebm-papst are used to exchange hot and cold air in all

More information

Low and Medium Voltage Motor Repair

Low and Medium Voltage Motor Repair Low and Medium Voltage Motor Repair Service Center (Shop) Selection and Evaluation Guide Why do we repair electric motors? To realize the benefit of added running hours without incurring the higher expense

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING

More information

Qualification Test Report VAL-U-LOK* Connectors

Qualification Test Report VAL-U-LOK* Connectors Qualification Test Report VAL-U-LOK* Connectors 501-534 09Apr09 Rev A 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on VAL-U-LOK* Connectors to determine their conformance to the requirements

More information

Product Specification JUL 14 Rev. A1

Product Specification JUL 14 Rev. A1 Industrial SCSI Connector 1. Scope 1.1 Contents This specification covers the requirements for product performance, test methods and quality assurance provisions of SCSI Connector. 2. Applicable Documents

More information

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing Switch Mode Power Supply (15/30/50/100/150/300/600/1,500-W Models) Power Supply Featuring OMRON s Unique, New Function with Compact Body Contributing to Machine Downsizing New undervoltage alarm function

More information

High Current Thermal Fuse

High Current Thermal Fuse High Current Thermal Fuse FEATURES Functioning temperature: F = (235 ± 15) C Holding temperature: H = 160 C Current: 55 A Material categorization: For definitions of compliance please see www.vishay.com/doc?99912

More information

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing Switch Mode Power Supply S8VM (15/30/50/100/150/300/600/1,500-W Models) Power Supply Featuring OMRON s Unique, New Function with Compact Body Contributing to Machine Downsizing New undervoltage alarm function

More information

POWER FACTOR REGULATOR. Computer-12e-xx INSTRUCTION MANUAL ( M / 02A ) (c) CIRCUTOR S.A.

POWER FACTOR REGULATOR. Computer-12e-xx INSTRUCTION MANUAL ( M / 02A ) (c) CIRCUTOR S.A. POWER FACTOR REGULATOR Computer-12e-xx INSTRUCTION MANUAL ( M 981 606 / 02A ) (c) CIRCUTOR S.A. -------- POWER FACTOR REGULATOR COMPUTER- 12e --------- Page 2 POWER FACTOR REGULATOR COMPUTER- 12e 1.- POWER

More information

Generator set data sheet. 410 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating

Generator set data sheet. 410 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating Generator set data sheet Model: Frequency: Fuel type: kw rating: DGDB 60 Hz Diesel 100 Standby 410 Prime Emissions level: EPA Nonroad Tier 1 Exhaust emission data sheet: Exhaust emission compliance sheet:

More information

Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft

Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Generator set data sheet Model: DQKAJ Frequency: 50 Hz Fuel type: Diesel kva rating: 2500 Standby 2000 Prime Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Exhaust emission data sheet:

More information

Bulkhead Feed-throughs

Bulkhead Feed-throughs 38999 series III Bulkhead Feed-throughs Connectors and interconnect systems for harsh environments The company designs, manufactures and markets high performance interconnect solutions for severe environments

More information

DRUM MOTOR 216LS 216.0Ø 0.11kW kW, with steel helical gearbox

DRUM MOTOR 216LS 216.0Ø 0.11kW kW, with steel helical gearbox 5 DRUM MOTOR UNIT HANDLING Product description The drum motor 16LS is able to provide high torques and withstand high radial loads. Characteristics Salt water resistant aluminum bearing housing Induction

More information

Generator set data sheet. 80 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating

Generator set data sheet. 80 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating Generator set data sheet Model: Frequency: Fuel type: kw rating: DGDB 50 Hz Diesel 85 Standby 80 Prime Emissions level: EPA Nonroad Tier 1 Exhaust emission data sheet: Exhaust emission compliance sheet:

More information

Vibranivo Mononivo. Series VN 4000 MN Series. Instruction manual

Vibranivo Mononivo. Series VN 4000 MN Series. Instruction manual Vibranivo Mononivo Series Series VN 4000 MN 4000 Instruction manual 010516 1 UWT GmbH Westendstraße 5 Tel.: +49 (0)831 57123-0 Internet:www.uwt.de D-87488 Betzigau Fax: +49 (0)831 76879 E-Mail: info@uwt.de

More information

Simple operation and a built-in bypass function make the CSX series a pleasure to use with many benefits in a tidy package.

Simple operation and a built-in bypass function make the CSX series a pleasure to use with many benefits in a tidy package. AuCom s CSX soft starters provide greater control over the starting and stopping of three phase motors. There are two product ranges: the CSX for a simple soft start control device, or the CSXi for an

More information

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P W

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P W These PV modules use squared, high-efficiency, polycrystalline silicon cells (the cells are made of several crystals of high purity silicon) to transform the energy of sunlight into electric energy. Each

More information

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60 Solar Innova uses the latest materials to manufacture photovoltaic modules. Our modules are ideal for any application that uses the photoelectric effect as a clean energy source because of its minimal

More information

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma

More information

Applications R46 K I P0 M

Applications R46 K I P0 M Overview The R46 Series is constructed of metallized polypropylene film encapsulated with self-extinguishing resin in a box of material meeting the requirements of UL 94 V 0. Applications For worldwide

More information

ABSORPTION HYBRID FILTER FAR-Q TYPE

ABSORPTION HYBRID FILTER FAR-Q TYPE ABSORPTION HYBRID FILTER FAR-Q TYPE USER MANUAL Code M98206701-03-07A ------ Absorption filter ------ User Manual, M98206701-03-07A ------ Page 1 of 11------ CONTENTS 1.- BASIC INSTRUCTIONS... 2 1.1.-

More information

Metal Composite Type Power Choke Coils

Metal Composite Type Power Choke Coils ETQ-PM Series Inductor Product Guide Metal Composite Type Power Choke Coils AEC-Q200 Compliant For Use In Harsh Environments Vibration Resistance of 10G ~ 30G (5Hz 2kHz) Maximum Operating Temperature of

More information

Introduction of an innovative base isolation system for seismic protection of HV components based on a combination of wire ropes and viscous dampers

Introduction of an innovative base isolation system for seismic protection of HV components based on a combination of wire ropes and viscous dampers Earthquake Resistant Engineering Structures X 147 Introduction of an innovative base isolation system for seismic protection of HV components based on a combination of wire ropes and viscous dampers M.

More information

APPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops.

APPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops. OPERATING LIMITS Flow rates up to : m /h Heads up to :, m Max. operating pressure : bar Max. loop temperature : +8 C Max. circulator temperature: C Max. ambient temperature : + C Water hardness (TH) :

More information

180 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3

180 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3 Generator set data sheet Model: Frequency: Fuel type: kw rating: DGGAE 60 Hz Diesel 200 Standby 180 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3 Exhaust emission data sheet: Exhaust emission

More information

1. MECHANICAL: 2.ELECTRICAL: Dimension of fan shall be shown in the outline styling drawing attached Dimension Motor Four-pole motor.

1. MECHANICAL: 2.ELECTRICAL: Dimension of fan shall be shown in the outline styling drawing attached Dimension Motor Four-pole motor. 1. MECHANICAL: 1-01 Dimension Dimension of fan shall be shown in the outline styling drawing attached. 1-02 Motor Four-pole motor. 1-03 Frame Plastic material UL V-0 1-04 Impeller Plastic material UL V-0

More information

RIELLO 40 N SERIES. One Stage Heavy Oil Burners FIRING RATES HEAVY OIL. N kw N kw

RIELLO 40 N SERIES. One Stage Heavy Oil Burners FIRING RATES HEAVY OIL. N kw N kw One Stage Heavy Oil Burners RIELLO 40 N SERIES The Riello 40 N series of one stage heavy oil burners, is a complete range of products developed to respond to any request for the use of heavy oil in heating

More information

Analysis of kva Savings with PowerPlus under Certain Conditions. Robert N Guenther, Jr. VP- Product Development and Engineering IEEE Fellow

Analysis of kva Savings with PowerPlus under Certain Conditions. Robert N Guenther, Jr. VP- Product Development and Engineering IEEE Fellow Introduction Analysis of kva Savings with PowerPlus under Certain Conditions Robert N Guenther, Jr VP- Product Development and Engineering IEEE Fellow One of the many reasons we designed PowerPlus, our

More information

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION Available range Unit type IH Heat pump IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS

More information

Delaware Electric Cooperative Generator Interconnection Application Long Form (For Use with Generators Greater than 100 kw)

Delaware Electric Cooperative Generator Interconnection Application Long Form (For Use with Generators Greater than 100 kw) An applicant (Generator Owner) makes application to to install and operate a generating facility greater than 100 kw interconnected with the utility system. Section 1, Applicant Information Directly Interconnected

More information

SUPPLY NETWORK ANALYZER CVM-SP SERIES INSTRUCTION MANUAL ( M / 01A

SUPPLY NETWORK ANALYZER CVM-SP SERIES INSTRUCTION MANUAL ( M / 01A SUPPLY NETWORK ANALYZER CVM-SP SERIES INSTRUCTION MANUAL ( M 981 310 / 01A ) (c) CIRCUTOR S.A. ----- CVM-SP & CVM-SP-RS485-C -------- --- Page No. 1 1.- MAIN FEATURES... 2 1.1.- Parameters measured and

More information