Cables for I/O Relay Terminals
|
|
- Maude Daniel
- 6 years ago
- Views:
Transcription
1 s for I/O Relay s XWZ-R Connect I/O Relay s to I/O Units for Programmable Controllers with one touch. for G70V and G7TC I/O Relay s and G70D, G70A, and G70R Relay s. s with loose wires available with or without crimp terminals. s available for programmable controllers from Mitsubishi Electric. Types and Table of Contents Connects to Appearance Description Name Model Wiring diagram Page Number Various devices This is convenient for connecting I/O Relay s to devices equipped with screw terminals. This has loose wires at the device end. s with Loose Wires and Crimp s s with Loose Wires 6 I/O points XWZ-RY C () 6 I/O points XWZ-RA C () Connects a PLC I/O Unit with Fujitsu connectors : to an I/O Relay. (:) 6 I/O points XWZ-R C () Fujitsu connectors Connects a PLC I/O Unit with Fujitsu connectors : to I/O Relay s. Note: The pin layout for PLC I/O Units with points is different for inputs and outputs. (:) 5 input points XWZ-RI C- () output points XWZ-RO C- (5) Connects a PLC I/O Unit with Fujitsu connectors : to I/O Relay s. (:) 8 I/O points XWZ-R C- - 6 (6) MIL connectors Connects a PLC I/O Unit with MIL connectors : to an I/O Relay. Connects a PLC I/O Unit with MIL connectors : to I/O Relay s. (:) (:) (:) 6 input points XWZ-RI C 6 output points XWZ-RO C (8) input points XWR-RI - -D (9) output points XWR-RO - -D 8 (0) 6 input points/ 6 output points XWZ-RM - -D () input points XWZ-RI - -D () 6 input points/ 9 XWZ-RM - -D () 6 output points 7 (7) Mitsubishi Electric PLCs Applicable models: For inputs: AX, ASX, ASX, QX, and QX For outputs: AY, ASY, ASY, QYP, and QYP Connects Mitsubishi Electric PLCs with -point connectors to I/O Relay s through a special cable. Mitsubishi Electric PLC Connecting s (:) input points XWZ-RI C-MN () 0 output points XWZ-RO C-MN (5)
2 XWZ-R Ordering Information Various devices Type Name Appearance length L (mm) Models s with Loose Wires and Crimp s XWZ-RY C 6 I/O points Device end 00 L I/O Relay,000 XWZ-RY00C,500 XWZ-RY50C,000 XWZ-RY00C,000 XWZ-RY00C 5,000 XWZ-RY500C s with Loose Wires XWZ-RA C 6 I/O points 00 L,000 XWZ-RA00C 5,000 XWZ-RA500C,000 XWZ-R00C Fujitsu connectors ( pins) (:) 6 I/O points,500 XWZ-R50C,000 XWZ-R00C XWZ-R C L,000 XWZ-R00C 5,000 XWZ-R500C (A),000 (B) 750 XWZ-RI00C-75 (A),500 (B),50 XWZ-RI50C-5 input points (A) (A),000 (B),750 XWZ-RI00C-75 Fujitsu connectors (0 pins) (:) XWZ-RI C- XWZ-RO C- output points (0) (B) Straight length (without bends) (A),000 (B),750 XWZ-RI00C-75 (A) 5,000 (B),750 XWZ-RI500C-75 (A),000 (B) 750 XWZ-RO00C-75 (A),500 (B),50 XWZ-RO50C-5 (A),000 (B),750 XWZ-RO00C-75 (A),000 (B),750 XWZ-RO00C-75 (A) 5,000 (B),750 XWZ-RO500C-75 (A) (B) (A),500 (B),50 (C),000 XWZ-R50C-5-00 Fujitsu connectors (56 pins) (:) XWZ-R C- - 8 I/O points (70) (0) (A),000 (B),750 (C),500 XWZ-R00C (C) Straight length (without bends) (A),000 (B),750 (C),500 XWZ-R00C MIL connectors (0 pins) (:) XWZ-RI C, XWZ-RO C 6 input points 6 output points L 50 XWZ-RI5C 500 XWZ-RI50C 50 XWZ-RO5C 500 XWZ-RO50C (:) input points output points (A) (A) 500 (B) 50 XWZ-RI50-5-D (A) 750 (B) 500 XWZ-RI75-50-D (A) 500 (B) 50 XWZ-RO50-5-D (A) 750 (B) 500 XWZ-RO75-50-D MIL connectors (0 pins) XWZ-RI - -D XWZ-RO - -D XWZ-RM - -D XWZ-RI - -D XWZ-RM - -D 6 input points/ 6 output points input points 6 input points/ 6 output points (0) (B) Straight length (without bends) (A) 500 (B) 50 XWZ-RM50-5-D (A) 750 (B) 500 XWZ-RM75-50-D (A) 500 (B) 50 XWZ-RI50-5-D (A) 750 (B) 500 XWZ-RI75-50-D (A) 500 (B) 50 XWZ-RM50-5-D (A) 750 (B) 500 XWZ-RM75-50-D
3 XWZ-R Type Name Appearance length L (mm) Models (A),000 (B) 750 XWZ-RI00C-75-MN Mitsubishi Electric PLCs with -point connectors (:) Applicable models: For inputs: AX, ASX, ASX, QX, and QX For outputs: AY, ASY, ASY, QYP, and QYP Mitsubishi Electric PLC Connecting s XWZ-RI C- -MN XWZ-RO C- -MN input points output points Device end (0) (A) I/O Relay (B) Straight length (without bends) (A),500 (B),50 XWZ-RI50C-5-MN (A),000 (B),750 XWZ-RI00C-75-MN (A),000 (B),750 XWZ-RI00C-75-MN (A),000 (B) 750 XWZ-RO00C-75-MN (A),500 (B),50 XWZ-RO50C-5-MN (A),000 (B),750 XWZ-RO00C-75-MN (A),000 (B),750 XWZ-RO00C-75-MN
4 XWZ-R Wiring diagram For various devices () s with Loose Wires and Crimp s (6 I/O points) XWZ-RY C Marker Insulation G70V/G7TC connec- Corresponding Dot Dot CN tube mark color Pin No. No. * color tor pin number* 0 BLUE RED 0 0 BLUE BLACK 0 9 PINK RED 9 9 PINK BLACK 9 8 GREEN RED GREEN BLACK ORANGE RED ORANGE BLACK GRAY RED GRAY BLACK BLUE RED 5 5 BLUE BLACK 5 PINK RED PINK BLACK GREEN RED 5 GREEN BLACK 6 ORANGE RED 7 ORANGE BLACK 8 GRAY RED 9 GRAY BLACK 0 *. Marker tube numbers and the G70V and G7TC connector pin numbers are same. Be careful when using with other models (Relay s). Refer to the datasheet for specific products for details. *. Refer to the datasheets for the G70V and G7TC for the connector pin layouts of I/O Relay s. () s with Loose Wires (6 I/O points) XWZ-RA C Corresponding Insulation CN Pin Dot mark Dot color G70V/G7TC connector pin number* color No. ORANGE BLACK 0 ORANGE RED 9 GRAY BLACK 8 GRAY RED 7 WHITE BLACK 6 WHITE RED 5 YELLOW BLACK YELLOW RED PINK BLACK 5 PINK RED 5 ORANGE BLACK 0 6 ORANGE RED 9 6 GRAY BLACK 8 7 GRAY RED 7 7 WHITE BLACK 6 8 WHITE RED 5 8 YELLOW BLACK 9 YELLOW RED 9 PINK BLACK 0 PINK RED 0 * Refer to the datasheets for the G70V and G7TC for the connector pin layouts of I/O Relay s Loose Wires and Crimp s (fork terminal (.5-)) XGM-00-T UL6 BC0P-SB AWG8(7/0.7) Interface cable ( color: Gray) Note:. The power line capacity is 50 ma max. per I/O point. Also, always check the driver capacity and I/O relay power consumption when using for outputs.. The crimp terminals are labeled with the corresponding connector pin numbers in parentheses. Refer to the Pin No. Tables for marker tube numbers.. Connect terminals 9 and 9 and terminals 0 and 0 together when using the G7TC-OC08.. The wire gauge of the wires in the cable is 8 AWG (7/ 0.7). Loose Wires XG5M-0-N XG5S-0 UL6 BC0P-SB AWG(7/0.0) Interface cable ( color: black) Note:. The wire gauge of the wires in the cable is AWG (7/ 0.0).. Connect terminals 9 and 9 and terminals 0 and 0 together when using the G7TC-OC08.
5 XWZ-R For Fujitsu connectors () (:) (6 I/O points) XWZ-R C CN CN CN A 0 B 9 A 8 B 7 A 6 B 5 A B 5A 5B 6A 0 6B 9 7A 8 7B 7 8A 6 8B 5 9A 9B 0A 0B A B A B A B CN 9 CN CN 0 () (:) ( input points) XWZ-RI C- CN CN CN A B A B A B A --- B --- 5A --- 5B --- 6A B A B A B A --- 9B --- 0A B A B A B A --- B --- A --- B --- 5A B A B A B A --- 8B --- 9A 9B 0A 0B CN (5) (:) ( output points) XWZ-RO C- CN CN CN A B A B A B A --- B --- 5A --- 5B --- 6A B A B A B A --- 9B --- 0A --- 0B --- A B A B A B A --- B --- 5A --- 5B --- 6A B A B A B A --- 9B --- 0A --- 0B --- CN CN FCN-67J0-AU/F * XGM-00-T UL6 BC0P-SB AWG8(7/ 0.7) Interface cable ( color: Gray) 0 A B * The connector is made by Fujitsu Component Ltd. CN CN and CN FCN-67J00-AU/FW * XGM-00-T UL6 BC0P-SB AWG8(7/0.7) Interface cable ( color: Gray) * The connector is made by Fujitsu Component Ltd. 5
6 XWZ-R For Fujitsu connectors (6) (:) (8 I/O points) XWZ-R C- - CN CN CN CN A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A 8B CN FCN-67J056-AU/FW* XGM-00-T UL6 BC0P-SB AWG8(7/0.7) Interface cable ( color: Gray) * The connector is made by Fujitsu Component Ltd. 9 CN CN 0 CN CN, CN, and CN 6
7 XWZ-R For MIL connectors (7) (:) (6 input points) XWZ-RI C CN CN (8) (:) (6 output points) XWZ-RO C CN CN CN CN 9 0 CN and CN XGM-00-T XGM-00-T UL6 BC0P-SB AWG8(7/0.7) Interface cable ( color: Gray) 7
8 XWZ-R For MIL connectors (9) (:) ( input points) XWZ-RI - -D CN CN CN (0) (:) ( output points) XWZ-RO - -D CN CN CN () (:) (6 input points/6 output points) XWZ-RM - -D CN CN CN CN CN mch * (IN mch) * CN m+ch * (OUT mch) * *. For the XWZ-RI/O - -D. *. For the XWZ-RM - -D XGM-00-T XGM-00-T UL6 BC0P-SB AWG8(7/0.7) Interface cable ( color: Gray) CN CN and CN 8
9 XWZ-R For MIL connectors () (:) ( input points) XWZ-RI - -D CN CN CN () (:) (6 input points/6 output points) XWZ-RM - -D CN CN CN CN CN mch * (IN mch) * CN m+ch * (OUT mch) * *. For the XWZ-RI - -D. *. For the XWZ-RM - -D XGM-00-T XGM-00-T UL6 BC0P-SB AWG8(7/0.7) Interface cable ( color: Gray) CN CN and CN 9
10 XWZ-R For Mitsubishi Electric PLCs () Mitsubishi Electric PLC Connecting s (:) ( input points) XWZ-RI C-MN CN CN CN A B --- A B --- A B A B 5A B A B A B A --- 8B --- 9A --- 9B --- 0A B A B A B A B A B A B A --- 6B --- 7A --- 7B --- 8A B A B A B Note: The G70V or G7TC connector pin numbers are not the same as the XWZ-R connector pin numbers. Refer to the datasheet for specific products for details. (5) Mitsubishi Electric PLC Connecting s (:) ( output points) XWZ-RO C-MN CN CN CN A --- B --- A --- B --- A B A B 5A B A B A B A --- 8B --- 9A --- 9B --- 0A B A B A B A B A B A B A --- 6B --- 7A --- 7B --- 8A B A B A B Note: The G70V or G7TC connector pin numbers are not the same as the XWZ-R connector pin numbers. Refer to the datasheet for specific products for details. CN CN CN A B FCN-67J00-AU/FW* XGM-00-T UL6 BC0P-SB AWG8(7/0.7) Interface cable ( color: Gray) * The connector is made by Fujitsu Component Ltd. CN CN and CN 0
11 XWZ-R Ratings and Specifications Rated current A Rated voltage 50 V Contact resistance 0 mω max. (at 0 mv, 00 ma max.) * Insulation resistance 000 MΩ min. (at 500 VDC) * Dielectric strength 500 VAC for min (leakage current: ma max.) Ambient operating temperature 0 to 80 C * These values are for the connectors. Safety Precautions Be sure to read Safety Precautions for All I/O Relay s in the website at: Warning Indications Precautions for Correct Use Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction, or undesirable effects on product performance. Precautions for Correct Use Wiring Do not perform wiring work, remove connectors, or connect connectors while power is being supplied. Electric shock or damage to the device may result. Double-check all wiring before turning ON the power supply. After wiring, route the cable so that force is not applied directly to the connections. Bending Radius of Connecting s To prevent damaging the Connecting s, use the following minimum bending radii as guidelines. Minimum bending radius Wiring diagram No. Model Minimum bending radius (mm) () XWZ-RY C 68 () XWZ-RA C 50 () XWZ-R C 68 () XWZ-RI C- (5) XWZ-RO C- 88 (6) XWZ-R C (7) XWZ-RI C (8) XWZ-RO C 68 (9) XWZ-RI - -D (0) XWZ-RO - -D () XWZ-RM - -D () XWZ-RI - -D 88 () XWZ-RM - -D () XWZ-RI C- -MN (5) XWZ-RO C- -MN Refer to the manuals for the connected PLC for the connections to I/O Units for OMRON PLCs. Series Model Man. No. Manual Name CS CSG-CPU H, CSH-CPU H W9 Programmable Controllers Operation Manual CJ CJH-CPU H-R, CJG/H-CPU H, CJG- CPU P, CJM-CPU, CJG-CPU W9 CJ Series Programmable Controllers Operation Manual CJ CJH-CPU6 -EIP, CJH-CPU6, CJM-CPU W7 CJ-series CJ CPU Unit Hardware User s Manual NJ NJ50- W500 NJ-series CPU Unit Hardware User's Manual NX NX-ID, NX-IA, NX-OD, NX-OC, NX-MD W5 NX-series Digital I/O Units User s Manual
12 MEMO
13 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, IIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGEE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.
14 OMRON Corporation Industrial Automation Company Kyoto, JAPAN Contact: Authorized Distributor: Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, JD Hoofddorp The Netherlands Tel: () /Fax: () OMRON ASIA PACIFIC PTE. LTD. No. 8A Alexandra Road # 05-05/08 (Lobby ), Alexandra Technopark, Singapore 9967 Tel: (65) 685-0/Fax: (65) OMRON ELECTRONICS LLC 895 Greenspoint Parkway, Suite 00 Hoffman Estates, IL 6069 U.S.A. Tel: () /Fax: () OMRON (CHINA) CO., LTD. Room, Bank of China Tower, 00 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 000, China Tel: (86) -507-/Fax: (86) OMRON Corporation 06 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Cat. No. G6-E-0 06 (06)
Cables for I/O Relay Terminals
s for I/O Relay s XWZ-R Connect I/O Relay s to I/O Units for Programmable Controllers with one touch. for G70V and G7TC I/O Relay s, G70D and G70R Relay s, and G70A and P7TF-IS/OS I/O Sockets. s with loose
More informationCables for I/O Relay Terminals
s for I/O Relay s XWZ-R Connect I/O Relay s to I/O Units for Programmable Controllers with one touch. s with s for G70V and G7TC I/O Relay s, G70D and G70R Relay s, and G70A and P7TF-IS/OS I/O Sockets.
More informationS8VM Series Replacement Brackets
Original model Bottom mounting Front mounting Side mounting Original model: S8VM Replacement model: S8FS-G Replacement bracket Model scheduled to be discontinued Recommended replacement model Model Page
More informationKey-type Selector Switches
New Product Key-type Selector Switches ANK Keyed -mm Selector Switches Universal Design. Emphasis on Color Coding, Workability, and Safety. Easy to Use You can connect up to three Blocks in one stage for
More informationE3X-DRT21/SRT21/CIF11
for E3X-DA-N-series Fiber Amplifiers /SRT21/CIF11 CSM SRT21_CIF11_DS_E_3_2 Three New s for Fiber Amplifiers DeviceNet CompoBus/S RS-422 Note: Manufacture of the E3X-DA6-P will be discontinued in March
More informationPS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm)
CSM_PS-_S(R)_-31_DS_E_7_1 Separate s for Water Supply and Drainage Control in Buildings. Small, Lightweight s for Use as Built-in Components. The PS-@S(R) are separate s that allow the s to be withdrawn
More informationZero cross function. DIN track mounting *2. Screw mounting
Solid State Contactors for Heaters Three-phase CSM_Three-phase_DS_E_3_1 Compact, Slim-profile SSRs with Heat Sinks. Solid State Contactors for Three-phase Heaters Reduced Installation Work with DIN Track
More informationMounting Brackets [Refer to Dimensions on page 6.]
Mounting Brackets E-L Slits/Reflectors E-S/E-R CSM_E-L/E-S/E-R_DS_E Mounting Brackets [Refer to Dimensions on page.] Model Fitting materials Count E-L Iron, zinc plating E-L0 Iron, zinc plating E-L Iron,
More informationOmron Robotic Automation Complete automation expertise
Omron Robotic Automation Complete automation expertise 2 Omron Robotic Automation Omron Robot Solution Flexible manufacturing enabled by a seamless integration of Robots and Machine Control Omron s unique
More informationSensors Temperature, Humidity, Light, Barometric pressure, Sound noise, 3-axis acceleration *1, etvoc *2
Sense a variety of environmental information Connects to a network via USB or Bluetooth to enable the sending of measurement data Using OMRON s unique and innovative algorithm, enables highly accurate
More informationE39-R3. Reflectors for photoelectric sensors. Ordering information
Reflectors for photoelectric sensors E39-R The E39-R series of reflectors for photoelectric sensors features a wide range of models with different sizes, shapes, types and materials. The reflectors provide
More informationCOMPLETE FLEXIBLE FEEDING SYSTEM
AnyFeeder Solution COMPLETE FLEXIBLE FEEDING SYSTEM 3 Faster Setup, Rapid Changeovers With intelligent software and fully integrated components, Omron AnyFeeder Solution is designed to help you move faster
More informationRobot Care. Annual Maintenance Agreement for Ensuring the Uptime of the Equipment
Robot Care Annual Maintenance Agreement for Ensuring the Uptime of the Equipment Expert service you can count on Cost-saving flat-rate service package Custom options to meet your specific needs Robot Care
More informationPackaging Machine Control Solutions. An electronic cam brings innovation to your packaging machines
Packaging Machine Control Solutions An electronic cam brings innovation to your packaging machines 2 Packaging Machine Control Solutions Craftsmanship at your finger tips Easily implement an electronic
More information2JCIE-BL. Sense a variety of environmental information. Model Number Structure. Ordering Information. Specifications. Environment Sensor.
Sense a variety of environmental information Includes six sensors, wireless functionality, and built-in battery Adopts Bluetooth low energy beacon technology for simple construction of a 1:n sensor network
More informationAutomation Software. Sysmac Studio. Minimize time to market Reduce installation cost Boost productivity
Automation Software Sysmac Studio Minimize time to market Reduce installation cost Boost productivity Sysmac Studio Your Automation Companion In changing market the customization and multiple variations
More informationOptoLum MegaLine RGBW Luminaire
OptoLum MegaLine RGBW Luminaire Getting Started OptoLum MegaLine RGBW Luminaires offer indoor cove lighting and wall washing in a compact linear form. This guide contains important information on planning,
More informationMobile Robots TRANSFORMING MANUFACTURING AND LOGISTICS
Mobile Robots TRANSFORMING MANUFACTURING AND LOGISTICS 1 Mobile Robots Transforming manufacturing and logistics Modernize Your Workflow Omron mobile robots are Autonomous Intelligent Vehicles (AIVs) designed
More informationOperating pressure Atmospheric pressure 1.96 MPa (See note 2.) 981 kpa (See note 2.) General applications for purified water and wastewater
Electrode Holder BF-@(R)/(T) Complete Lineup for Use in Hightemperature, High-pressure Environments or Where Exposed to Chemicals The BF-1 is ideal for liquids with low specific resistance, such as wastewater.
More informationOriginal instructions JSNY7 Magnetic switch
Original instructions JSNY7 Magnetic switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.jokabsafety.com Read and understand this document Please read and understand this
More informationPush-In Plus Terminal Block Sockets
New Product Push-In Plus Terminal Block Sockets PYF-@@-PU/P2RF-@@-PU Sockets with Push-In Plus Terminal Blocks Reduce Wiring Time for Relays and Timers Wiring time is reduced by 60%* in comparison with
More information3M D Sub Socket 50 Position 8350 Series
M D Sub Socket 50 Position 850 Series IDC compatible Lower insertion/withdrawal force than other 50 position products Available in either open or closed end cover Mounting options include #4-40 UNC or
More informationRL4050LS. Electronic Load Shackle. Installation Guide
RL4050LS Electronic Load Shackle Installation Guide 1 70997 Contents 1. Introduction... 1 2. General Installation of the Load Shackle... 2 3. Load Cell Wiring... 2 4. Load Shackle Specifications... 3 5.
More informationAll Models Unless Indicated Safety Contacts: AC models MA-S2, 36 1 N/C MA-S20, S21 2 N/C DC models MA-S2, 34, 36 1 N/C MA-S20, S21, 35, 36 2 N/C
R Safety Interlock Switches MA-S Series Stainless Steel Magnetically Actuated Safety Interlock Switches and Actuators Stainless steel cases both switch and actuator are housed in stainless steel for applications
More informationPhase-sequence Phase-loss Relay
Phase-sequence Phase-loss Relay K8AK-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Greater resistance to inverter noise. Distinguishes between correct phases, phase sequence,
More information3M Molded Socket for.050 Pitch Cable, Cable Assembly Connector 871 Series
3M Molded Socket.100.100 for.050 Pitch Cable, Cable Assembly Connector 871 Series Part of a complete cable assembly Mates with industry standard 0.025 inch square contacts on.100 inch x.100 inch centers
More informationOrdering Information. Conductive Level Controller 61F-GP-N2. Accessories (Order Separately) Selection Guide for Electrode Holders and Separators
Conductive Level Controller CSM DS_E_1_ Automatic Water Supply and Drainage Control Ideal for level control of any conductive liquid. Compact plug-in controller for single- or two-point control of conductive
More informationP1902 Installation Manual
P1902 Installation Manual Precision Lighting Controller P1902-JRev. 1.0 2010 Profile Systems, LLC 1000 E. 80 th Place Suite 777 South Merrillville, IN 46410 (800) 898-5483 www.profilesystems.com Revision
More information3M Ground Plane Cable.050" 28 AWG Stranded, One Drain, PVC 3476 Series
M Ground Plane Cable.050" 28 AWG Stranded, One Drain, PVC 476 Series 28 AWG wire on.050 inch centers permits mass termination to a broad line of IDC connectors Ground plane construction for increased signal
More information3M Scotchlok Copper Compression Lugs, and Series
Copper Compression s, 30000 and 31000 Series Data Sheet June 2011 Description Copper Compression s are one-piece, seamless copper and are designed to cover a wide range of conductor sizes. They are available
More informationDaniel Orifice Fittings and Meter Tubes
Installation and Operating Instructions P/N 3-9008-002, Rev E November 2017 Daniel Orifice Fittings and Meter Tubes Specific to the Pressure Equipment Directive Flow Lifecycle Services for Daniel products
More informationContents CONTACT INFORMATION... 2
Contents CONTACT INFORMATION... 2 1. Introduction... 3 2. Technical specifications... 4 3. Installation of transponder... 5 4. installation of driver-id selector... 7 5. GUARANTees & Warranties... 8 Contact
More information3M PCB Connector.100 Four Row 3400 Series
PCB Connector.00 Four Row 300 Series Low profile Standard staggered grid Variety of pin lengths and plating options available See Regulatory Information Appendix (RIA) for chemical compliance information
More informationWash Down Duty Non-Contact Sensor
Wash Down Duty Non-Contact Sensor Instruction Manual Models WDDC1-020/040/060/080/100 WDDC2-020/040/060/080/100 WDDV1-020/040/060/080/100 WDDV2-020/040/060/080/100 Table of Contents 1. General Description.....................................
More informationFigure 1 Input power cable (left) and output power cable (right)
TIDA-00282 Cable Assemblies These cable assemblies are intended for use with the C2000-based Automotive Digitally-controlled Boost Power Supply board described in TI Designs TIDA-00282. Figure 1 Input
More informationH8SX/1650 Series E6000H TFP-120 User System Interface Board User s Manual HS1650ECN61H
H8SX/1650 Series E6000H TFP-120 User System Interface Board User s Manual HS1650ECN61H Rev.3.00 2003.10.6 Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum
More information3M Medium-Wall Heat Shrink Tubing IMCSN
3M Medium-Wall Heat Shrink Tubing IMCSN Data Sheet November 2017 Product Description 3M Medium-Wall Heat Shrink Tubing IMCSN is designed to provide reliable performance for electrical splices, connections,
More information5020 SERIES HERMETICALLY SEALED THERMOSTAT PROBE
5020 SERIES HERMETICALLY SEALED THERMOSTAT PROBE Introduction The 5020 series is a single throw, snap-action, hermetically sealed temperature control designed for applications requiring high vibrational
More informationT1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features
INSTRUCTION SHEET T1000 Transformer for Magnetic-Field Susceptibility Testing Features Up to 100 A RMS secondary current Exceeds AF Magnetic Field test requirements of DO 160 Section 19 and Boeing D6-16050-5
More informationThermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N
Thermoelectric Coolers All Models INSTRUCTION MANUAL Rev. G 2016 Pentair Equipment Protection P/N 89072602 89072603 TABLE OF CONTENTS RECEIVING THE THERMOELECTRIC COOLER...3 HANDLING & TESTING THE THERMOELECTRIC
More informationEND TRUCKS WHEEL SIZES: 9", 12", 15" & 18"
OPERATION, SERVICE & PARTS MANUAL STRUCTURAL TUBE ROTATING AXLE WHEEL SIZES: 9", ", 5" & 8" P/N: 5367 REV. AA November 03 ROTATING TOP AXLE RUNNING END ROTATING TRUCK PARTS AXLE BREAKDOWN END TRUCK P/N:
More informationProcess Returns in VOTW
Process Returns in VOTW 1. From the Menu bar, select Other Functions Returns. 2. From the Returns Action list, select one of the following: Add a Claim Request: Request a new return on an Eaton product.
More informationDistributed by: www.jameco.com 1-800-81-4242 The content and copyrights of the attached material are the property of its owner. M Wiremount Socket.100.100 for.050 Pitch Cable 891 Series Preassembled, terminates
More informationThermoelectric Cooler
INSTRUCTION MANUAL Thermoelectric Cooler TE090624020, TE121024020, TE121048020, TE162024020, TE162048020, TE090624010, TE121024010, TE121048010, TE162024010, TE162048010, TE090624011, TE121024011, TE162024011
More informationIron, zinc plating. (with spring and plain washers) Nuts M4 Iron, zinc plating 2
Mounting Brackets E-L/F-L Slits/Reflectors E-S/E-R CSM_E-L_F-L_E-S_E-R_DS_E Mounting Brackets Model Fitting materials Count E-L Iron, zinc plating Accessories Applicable sensor Page (mounting pitch on
More information0.3 A max., fuse externally 0.2 A quick acting Internal Fuse: AC models 2 A fast acting
R Safety Interlock Switches MA Series Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic to satisfy most application
More informationAgilent 16048D Test Leads
Agilent 16048D Test Leads Operation and Service Manual Fourth Edition Agilent Technologies Japan, Ltd. Agilent PN 16048-90031 May 2000 Printed in Japan Notices The information contained in this document
More informationUSER MANUAL MODEL 1019 and 1019S DB-9 Async. Short Range Modem With Transformer Isolation
USER MANUAL MODEL 1019 and 1019S DB-9 Async. Short Range Modem With Transformer Isolation C E R T I F I E D An ISO-9001 Certified Company Part# 07M1019-C Doc# 051021UC Revised 06/03/99 SALES OFFICE (301)
More information3M Round, Shielded/Jacketed, Disc. Wire Cable 26 AWG Solid, Twisted Pair, PVC/PVC 3560 Series
M Round, Shielded/Jacketed, Disc. Wire Cable 26 AWG Solid, Twisted Pair, PVC/PVC 560 Series Twisted pairs reduce crosstalk for balanced drive applications Dual shielding provides 5 db average shielding
More information3M Medium-Wall Heat Shrink Tubing IMCSN
3M Medium-Wall Heat Shrink Tubing IMCSN Data Sheet April 2017 Product Description 3M Medium-Wall Heat Shrink Tubing IMCSN is designed to provide reliable performance for electrical splices, connections,
More information3M Eurosocket Type C (Rows A & C or A, B & C Filled)
DIN 41612 compatible High density (64 & 96 position) Mates with DIN 41612 Type C headers High reliability contact design Can be daisy-chained or end terminated to flat cable Optional strain relief with
More information3M D Sub EMI Junction Shell Metalized Plastic
M D Sub EMI Junction Shell Metalized Plastic Protection from EMI/ESD Easy assembly reduces time and labor to ensure low applied cost Light weight, compact design Strain relief compensates for multiple
More informationPallet Puller. Owner s Manual
Pallet Puller Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result
More informationThe Netherlands Tel: Tel: +1 (678) Tel: Tel: +61 (0)
Contact Information MYLAPS EMEA Office MYLAPS Americas Office Haarlem Atlanta The Netherlands USA Tel: +31 23 529 1893 Tel: +1 (678) 816 4000 E-mail: E-mail: info@mylaps.com info.americas@mylaps.com MYLAPS
More informationAgilent 16034E Test Fixture
Agilent 16034E Test Fixture Operation and Service Manual Third Edition Agilent PN 16034-90041 December 1999 Printed in: Japan Notices The information contained in this document is subject to change without
More information3M Cold Shrink Silicone Rubber Connector Insulators 8440 Series
3M Cold Shrink Silicone Rubber Connector Insulators 8440 Series Data Sheet May 2014 Product Description 3M Cold Shrink Connector Insulators 8440 Series are open-ended, silicone rubber, tubular sleeves.
More informationDaniel TM Ultrasonic Flow Meters
Installation and Operating Instructions Manual Part Number 3-9000-745 Revision F August 2017 Daniel TM Ultrasonic Flow Meters Installation and Operating Instructions Specific to the Pressure Equipment
More information117-Bin Wire Shelf Storage Rack
117-Bin Wire Shelf Storage Rack Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
More informationTL-600 MOBILE PHASE HEATER
TL-600 MOBILE PHASE HEATER INSTRUCTION MANUAL Timberline Instruments, Inc. 1880 S. Flatiron Ct., Unit I Boulder, Colorado 80301 Ph: (303) 440-8779 Fx: (303) 440-8786 info@timberlineinstruments.com www.timberlineinstruments.com
More informationAgilent 16048B Test Leads Operating Note Third Edition Agilent Part No May 2000
Agilent 16048B Test Leads Operating Note Third Edition Agilent Part No. 16048-90012 May 2000 Printed in Japan Notices The information contained in this document is subject to change without notice. This
More informationAgilent 16047D Test Fixture
Agilent 16047D Test Fixture Operation and Service Manual Third Edition Agilent Technologies Japan, Ltd. Agilent PN 16047-90300 May 2000 Printed in Japan Notices The information contained in this document
More information66-Bin Wire Shelf Storage Rack
66-Bin Wire Shelf Storage Rack Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
More informationSignal Follower Card. Instruction Manual Model C
Signal Follower Card Instruction Manual Model C10032-000 Table of Contents General Description... 2 Features... 3 Typical Applications....3 Specifications... 3 Adjustment Procedure... 4 Prints... 5 Standard
More information3M I/O Interconnect System 2.0 mm for IEEE 1394
M I/O Interconnect System 2.0 mm for IEEE 194 Shell Kit for Receptacle E06 Series Complete shell kit for M 2.0 mm I/O Interconnect System for IEEE 194 Wiremount Receptacle (TS-2296) Includes outer body,
More informationPD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER
PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER 4-20 ma input 1 V drop (4 V with Backlight) 3½ Digits LCD, 1" High Loop-Powered Backlight Option HART Protocol Transparent Plastic NEMA 4X, IP65 Enclosure
More information3M Heavy Wall Heat Shrink Tubing ITCSN
3M Heavy Wall Heat Shrink Tubing ITCSN Data Sheet September 2013 Description 3M Heavy Wall Heat Shrink Tubing ITCSN is designed to provide reliable performance for electrical splices, connections, and
More informationPalletPal Low Profile Disc Turntable
OWNER S MANUAL PalletPal Low Profile Disc Turntable Model # Serial # Date placed in Service SOUTHWORTH PRODUCTS CORP P.O. Box 1380 Portland, ME 04104-1380 Telephone: (207) 878-0700 or (800) 743-1000 Fax:
More information3M Pleated Foil Shielded Cable.025" 30 AWG Solid, TPE Primary, PVC Jacket, Low Skew Series
3M Pleated Foil Shielded Cable.025" 30 AWG Solid, TPE Primary, PVC Jacket, Low Skew 93101 Series Skew of less than 100 picoseconds/meter when terminated in unbalanced mode, with even wire signals (excluding
More information5100 SERIES HERMETICALLY SEALED THERMOSTAT PROBE Introduction
5100 SERIES HERMETICALLY SEALED THERMOSTAT PROBE Introduction The 5100 series is a single pole, single throw, snap-action, hermetically sealed temperature control designed for applications requiring high
More informationMake Your SMT Production More Efficient while Achieving Zero Defects NEW. [ Faster ] Compared to the first generation VT-RNS
Inline PCB Inspection System VT-RNSII For Even More Efficient SMT Production Introducing the 2nd Generation RNS Series Make Your SMT Production More Efficient while Achieving Zero Defects PCB Inspection
More information3M Wiremount Socket Position for.050 Pitch Cable 79 Series
3M Wiremount Socket.100.100 64 Position for.050 Pitch Cable 79 Series Standard profile plastic strain relief Mates with 3M headers, plugs, and pin strips for quick connect/disconnect capability Centerbump
More informationISIMET. E Series Enclosure. Custom Assemblies Installation, Maintenance, and Operation Instructions
ISIMET E Series Enclosure Custom Assemblies Installation, Maintenance, and Operation Instructions The Custom Assembled E-Series Enclosures is pre-assembled and pre-wired enclosure intended for use with
More information3M Pin Strip Header 2 mm and 2 mm x 2 mm Straight, Surface Mount 951 Series
3M Pin Strip Header 2 mm and 2 mm x 2 mm Straight, Surface Mount 951 Series High temperature dielectric No lead reflow solder compatible Maximizes use of PC board space End stackable feature Mates with
More information3M Mini D Ribbon (MDR) Connectors.050 Boardmount Through-Hole Right Angle Receptacle - Shielded 102 Series
M Mini D Ribbon (MDR) Connectors.050 Boardmount Through-Hole Right Angle Receptacle - Shielded 102 Series Wiper-on-wiper contact for reliable repetitive plugging Surface mount compatible PCT insulator
More informationModel 3185E DUAL TONE DECODER INSTRUCTION MANUAL
Model 3185E DUAL TONE DECODER INSTRUCTION MANUAL Monroe Electronics 100 Housel Ave Lyndonville NY 14098 phone 585-765-2254 fax 585-765-9330 monroe-electronics.com Printed in USA Copyright Monroe Electronics,
More informationDouble-Drum Forklift Gripper
Double-Drum Forklift Gripper Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
More information3M Link Connector.100" Boardmount, Straight and Right Angle 382 Series
3M Link Connector.100" Boardmount, Straight and Right Angle 382 Series Mates with 3M Wiremount Link Connector 38104 Vertical or right angle configuration Accepts latch mechanism of Wiremount Link Connector
More informationPressure Sensitive Adhesives for HVAC/R, Mechanical and Metal Building Insulation. Tapes, Fasteners & Sealants Product Catalog
Pressure Sensitive Adhesives for HVAC/R, Mechanical and Metal Building Insulation Tapes, Fasteners & Sealants Product Catalog HVAC Fastening Systems PRODUCT DESCRIPTION AVAILABLE SIZES ROLLS/CASE ORDER
More information3M Shielded Compact Ribbon (SCR) Connectors Boardmount Right Angle Plug
M Shielded Compact Ribbon (SCR) Connectors Boardmount Right Angle Plug 61 Series Robust ribbon style contact for reliable, repetitive plugging Body tabs provide lateral support to solder joints and help
More information3M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series
3M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series Wiper-on-wiper contact for reliable repetitive plugging Ultra-low signal skew for high data rate transmission
More information3M Round, Jacketed, Flat Cable.050" 28 AWG Stranded, Mass-Term, PVC/PVC 3759 Series
M Round, Jacketed, Flat Cable.050" 28 AWG Stranded, Mass-Term, PVC/PVC 759 Series Round construction permits easier routing 28 AWG wire on.050 inch centers permits mass termination to broad line of IDC
More informationRSD250 Unwind Dancer Package WEB CONTROL PRODUCTS FORM NO. L B User Manual. MTY (81)
WEB CONTROL PRODUCTS User Manual RSD250 Unwind Dancer Package FORM NO. L-279-B-003 FORM NO. L-279-B-003 In accordance with Nexen s established policy of constant product improvement, the specifications
More informationXBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.
XBDM-HW63 63A Model User & Installation Manual www.xpcc.com 2016. All rights reserved. (Rev 3/02/16) Table of Contents Introduction...3 Product Overview... 3 Installation and Operation...4 Inspection...4
More informationInstallation and Use Instructions for the Big Ass Workbench Manufactured by Mercer Innovation, LLC
Introduction Mercer Innovation, LLC has proudly and domestically manufactured the first in a line of industrial benches and furniture for serious shop use, as described below. Description The Big ASS workbench,
More informationGeneral Safety Information
TM General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationPhysical. Electrical. Environmental. Insulation: Contact: Plating: Shroud: Temperature Rating: -55 C to +85 C
M I/O Interconnect System 2.0 mm for IEEE 194 Right Angle, Horizontal, Through-Hole Plug (Male) E106 Series Robust ribbon style contact for reliable, repetitive plugging Body tabs provide lateral support
More informationN E W. Inline PCB inspection system VT-S VT S500series
N E W Inline PCB inspection system VT-S500-02 VT S500series Market environment Various needs surrounding the surface mount industry Globalized issues in the surface mounting industry Demands from the market
More informationJ1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL
J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL Revision 1.01 1 Introduction...2 1.1 Firmware Revision...2 1.2 Product Features...2 2 Installation...3 2.1 Unpacking the box...3 2.2 Mounting the
More informationInstruction Manual V2.0. Instruction Manual. Laser Diode Drivers Models: LSP-500/1000/1500/-XK-XX
Instruction Manual Laser Diode Drivers Models: LSP-500/1000/1500/-XK-XX This manual contains Operating, Safety, and Maintenance information and subjects to change without notice. Lic engineering 3735 Coffey
More information3M Round Conductor Flat Cable.025" 30 AWG Stranded, PVC 3754 Series
M Round Conductor Flat Cable.025" 0 AWG Stranded, PVC 754 Series Close spacing permits higher signal density PVC insulation provides excellent flexibility 0 AWG stranded on.025 inch spacing allows for
More informationAPC Step-Down Transformer. Models: AP9626, AP9627, and AP9628
User Manual English APC Step-Down Transformer Models: AP9626, AP9627, and AP9628 990-7820F 06/2006 Introduction Introduction The APC step-down transformers are used to convert a higher input voltage (208-200
More informationDUST FREE ACTIVE Total Home Air Purification
DUST FREE ACTIVE Total Home Air Purification Installation & Operation Manual This manual covers the following models: DF ACTIVE 6" - #13070 DF ACTIVE 12" - #13071 GENERAL This device is designed to be
More informationGeneral-Purpose Scale Bases
General-Purpose Scale Bases Models LB30, LB60, PL100, PL150 Instruction Manual Ohaus Corporation 1994, all rights reserved. TABLE OF CONTENTS INTRODUCTION... 3 DESCRIPTION... 3 UNPACKING... 4 INSTALLATION...
More informationDrag Chain Conveyor Installation and Operation Manual
Drag Chain Conveyor Installation and Operation Manual Material Handling Equipment Sales, Incorporated 310 S. Section Line Rd Delaware, OH 43015 Phone: (989) 430-4005 Fax: (740) 363-9004 WARRANTY MATERIAL
More informationMiniature Helium Purifier and Nitrogen Purifier Instruction Manual
Valco Instruments Co. Inc. Miniature Helium Purifier and Nitrogen Purifier Instruction Manual For item numbers: HPM HPM-220 NPM NPM-220 HPM.p65 1/11 Printed in USA Valco Instruments Co. Inc. 800 367 8424
More informationThin Film Platinum RTDs. HRTS Series. Datasheet
Thin Film Platinum RTDs HRTS Series Datasheet Thin Film Platinum RTDs The HRTS Series Thin Film Platinum RTDs (Resistance Temperature Detectors) are designed to measure temperatures from -70 C to 260 C
More information3M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series
M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 659 Series Round construction permits easier routing 28 AWG wire on.050 inch pitch permits mass termination to broad
More informationLionel #213 Lift Bridge Owner s Manual /02
Lionel #213 Lift Bridge Owner s Manual 71-4167-250 11/02 Congratulations! Congratulations on your purchase of the Lionel #213 Lift Bridge! With the help of two counterweights, the center section of track
More informationInstructions and E00 Series Sampling Module Extenders
Instructions 012-1568-00 and 012-1569-00 80E00 Series Sampling Module Extenders 071-0436-01 www.tektronix.com 071043601 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by
More informationINSTALLATION & OPERATION INSTRUCTIONS ICW-3 WINDOW INTERCOM
INSTALLATION & OPERATION INSTRUCTIONS ICW-3 WINDOW INTERCOM 9350-7686-000 Rev. H 08/2004 TRADEMARKS AudioCom is a registered trademark of Telex Communications. Names of other products mentioned herein
More information