Cables for I/O Relay Terminals

Size: px
Start display at page:

Download "Cables for I/O Relay Terminals"

Transcription

1 s for I/O Relay s XWZ-R Connect I/O Relay s to I/O Units for Programmable Controllers with one touch. s with s for G70V and G7TC I/O Relay s, G70D and G70R Relay s, and G70A and P7TF-IS/OS I/O Sockets. s with loose wires available with or without crimp terminals. s available for programmable controllers from Mitsubishi Electric. Types and Table of Contents Connects to Appearance Description Name I/O Classification Typical model Wiring diagram Page Number Connections with terminal blocks of various devices This is convenient for connecting I/O Relay s to devices equipped with screw terminals. This has loose wires at the device end. s with Loose Wires and Crimp s s with Loose Wires 6 I/O points XWZ-RY C () 6 I/O points XWZ-RA C () Connects a PLC I/O Unit, DeviceNet slave or other device with Fujitsu connectors : to an I/O Relay. s with s (:) 6 I/O points XWZ-R C () Fujitsu connectors Connects a PLC I/O Unit, DeviceNet slave, or other device with Fujitsu connectors : to I/O Relay s. s with s (:) 5 input points XWZ-RI C- () output points XWZ-RO C- (5) Connects a PLC I/O Unit, DeviceNet slave, or other device with Fujitsu connectors : to I/O Relay s. s with s (:) 8 I/O points XWZ-R C- - 6 (6) Connects a PLC I/O Unit, De-viceNet slave, or other device with MIL connectors : to an I/O Relay. s with s (:) 6 input points/ 6 output points XWZ-RO C (7) 7 XWZ-RI C (8) MIL connectors Connects a PLC I/O Unit, DeviceNet slave, or other device with MIL connectors : to I/O Relay s. s with s (:) input points/ output points XWZ-RO - -D (9) 8 XWZ-RI - -D (0) XWZ-RI - -D () Connects a DeviceNet slave or other device with MIL connectors : to I/O Relay s. 6 input points/ 6 output points ( I/O points) XWZ-RM - -D () 9 XWZ-RM - -D () Mitsubishi Electric PLCs Applicable models: For inputs: AX, ASX, ASX, QX, and QX For outputs: AY, ASY, ASY, QYP, and QYP Connects Mitsubishi Electric PLCs with -point connectors to I/O Relay s through a special cable. Mitsubishi Electric PLC Connecting s (:) input points XWZ-RI C-MN Note: For combinations of Connections, refer to I/O Relay s and Connected Devices (Cat. No. J7) or to the datasheets for related products. 0 () output points XWZ-RO C-MN (5)

2 XWZ-R Ordering Information Type () Name I/O Classification Appearance length L (mm) Models,000 XWZ-RY00C s with Loose Wires,500 XWZ-RY50C Device end I/O Relay and Crimp s 6 I/O points,000 XWZ-RY00C XWZ-RY C,000 XWZ-RY00C Loose wire connections 00 L 5,000 XWZ-RY500C s with Loose Wires XWZ-RA C 6 I/O points 00 L,000 XWZ-RA00C 5,000 XWZ-RA500C,000 XWZ-R00C Fujitsu connectors ( pins) s with s (:) 6 I/O points,500 XWZ-R50C,000 XWZ-R00C XWZ-R C L,000 XWZ-R00C 5,000 XWZ-R500C (A),000 (B) 750 XWZ-RI00C-75 (A),500 (B),50 XWZ-RI50C-5 input points (A) (A),000 (B),750 XWZ-RI00C-75 Fujitsu connectors (0 pins) s with s (:) XWZ-RI C- XWZ-RO C- output points (0) (B) Straight length (without bends) (A),000 (B),750 XWZ-RI00C-75 (A) 5,000 (B),750 XWZ-RI500C-75 (A),000 (B) 750 XWZ-RO00C-75 (A),500 (B),50 XWZ-RO50C-5 (A),000 (B),750 XWZ-RO00C-75 (A),000 (B),750 XWZ-RO00C-75 (A) 5,000 (B),750 XWZ-RO500C-75 (A) (B) (A),500 (B),50 (C),000 XWZ-R50C-5-00 Fujitsu connectors (56 pins) s with s (:) XWZ-R C- - 8 I/O points (0) (70) (A),000 (B),750 (C),500 XWZ-R00C (C) Straight length (without bends) (A),000 (B),750 (C),500 XWZ-R00C MIL connectors (0 pins) s with s (:) XWZ-RO C XWZ-RI C 6 I/O points L 50 XWZ-RO5C 500 XWZ-RO50C 50 XWZ-RI5C 500 XWZ-RI50C

3 XWZ-R Type () Name I/O Classification Appearance length L (mm) Models (A) 500 (B) 50 XWZ-RO50-5-D MIL connectors (0 pins) Mitsubishi Electric PLCs with -point connectors (:) Applicable models: For inputs: AX, ASX, ASX, QX, and QX For outputs: AY, ASY, ASY, QYP, and QYP s with s (:) XWZ-RO - -D, XWZ-RI - -D, XWZ-RI - -D, XWZ-RM - -D*, XWZ-RM - -D* Mitsubishi Electric PLC Connecting s XWZ-RI C- -MN XWZ-RO C- -MN I/O points 6 inputs and 6 outputs ( I/O points) input points output points Device end Note: For a connector pin assignment diagram and cable color information, refer to the wiring drawings. * These cables are used to connect to slave products for DeviceNet and other networks. (0) (B) Straight length (without bends) (0) I/O Relay (A) (A) (B) Straight length (without bends) (A) 750 (B) 500 XWZ-RO75-50-D (A),000 (B) 750 XWZ-RO00-75-D (A),500 (B),50 XWZ-RO50-5-D (A),000 (B),750 XWZ-RO00-75-D (A),000 (B),750 XWZ-RO00-75-D (A) 5,000 (B),750 XWZ-RO D (A) 500 (B) 50 XWZ-RI50-5-D (A) 750 (B) 500 XWZ-RI75-50-D (A),000 (B) 750 XWZ-RI00-75-D (A),500 (B),50 XWZ-RI50-5-D (A),000 (B),750 XWZ-RI00-75-D (A),000 (B),750 XWZ-RI00-75-D (A) 5,000 (B),750 XWZ-RI D (A) 500 (B) 50 XWZ-RI50-5-D (A) 750 (B) 500 XWZ-RI75-50-D (A) 500 (B) 50 XWZ-RM50-5-D (A) 750 (B) 500 XWZ-RM75-50-D (A),000 (B) 750 XWZ-RM00-75-D (A),500 (B),50 XWZ-RM50-5-D (A),000 (B),750 XWZ-RM00-75-D (A),000 (B),750 XWZ-RM00-75-D (A) 5,000 (B),750 XWZ-RM D (A) 500 (B) 50 XWZ-RM50-5-D (A) 750 (B) 500 XWZ-RM75-50-D (A),000 (B) 750 XWZ-RI00C-75-MN (A),500 (B),50 XWZ-RI50C-5-MN (A),000 (B),750 XWZ-RI00C-75-MN (A),000 (B),750 XWZ-RI00C-75-MN (A),000 (B) 750 XWZ-RO00C-75-MN (A),500 (B),50 XWZ-RO50C-5-MN (A),000 (B),750 XWZ-RO00C-75-MN (A),000 (B),750 XWZ-RO00C-75-MN

4 XWZ-R Wiring diagram For various devices () s with Loose Wires and Crimp s (6 I/O points) XWZ-RY C Marker Insulation G70V/G7TC connec- Corresponding Dot Dot CN tube mark color Pin No. No. * color tor pin number* 0 BLUE RED 0 0 BLUE BLACK 0 9 PINK RED 9 9 PINK BLACK 9 8 GREEN RED GREEN BLACK ORANGE RED ORANGE BLACK GRAY RED GRAY BLACK BLUE RED 5 5 BLUE BLACK 5 PINK RED PINK BLACK GREEN RED 5 GREEN BLACK 6 ORANGE RED 7 ORANGE BLACK 8 GRAY RED 9 GRAY BLACK 0 *. Marker tube numbers and the G70V and G7TC connector pin numbers are same. Be careful when using with other models (Relay s). Refer to the datasheet for specific products for details. *. Refer to the datasheets for the G70V and G7TC for the connector pin layouts of I/O Relay s. () s with Loose Wires (6 I/O points) XWZ-RA C Corresponding Insulation CN Pin Dot mark Dot color G70V/G7TC connector pin number* color No. ORANGE BLACK 0 ORANGE RED 9 GRAY BLACK 8 GRAY RED 7 WHITE BLACK 6 WHITE RED 5 YELLOW BLACK YELLOW RED PINK BLACK 5 PINK RED 5 ORANGE BLACK 0 6 ORANGE RED 9 6 GRAY BLACK 8 7 GRAY RED 7 7 WHITE BLACK 6 8 WHITE RED 5 8 YELLOW BLACK 9 YELLOW RED 9 PINK BLACK 0 PINK RED 0 * Refer to the datasheets for the G70V and G7TC for the connector pin layouts of I/O Relay s Loose Wires and Crimp s (fork terminal (.5-)) XGM-00-T (MIL connector) UL6 BC0P-SB AWG8(7/0.7) Interface cable ( color: Gray) Note:. The power line capacity is 50 ma max. per I/O point. Also, always check the driver capacity and I/O relay power consumption when using for outputs.. The crimp terminals are labeled with the corresponding connector pin numbers in parentheses. Refer to the Pin No. Tables for marker tube numbers.. Connect terminals 9 and 9 and terminals 0 and 0 together when using the G7TC-OC08.. The wire gauge of the wires in the cable is 8 AWG (7/ 0.7). Loose Wires XG5M-0-N XG5S-0 (MIL connector) UL6 BC0P-SB AWG(7/0.0) Interface cable ( color: Black) Note:. The wire gauge of the wires in the cable is AWG (7/0.0).. Connect terminals 9 and 9 and terminals 0 and 0 together when using the G7TC-OC08.

5 XWZ-R For Fujitsu connectors () s with s (:) (6 I/O points) XWZ-R C CN CN CN A 0 B 9 A 8 B 7 A 6 B 5 A B 5A 5B 6A 0 6B 9 7A 8 7B 7 8A 6 8B 5 9A 9B 0A 0B A B A B A B CN 9 CN CN 0 () s with s (:) ( I/O points) XWZ-RI C- CN CN CN A B A B A B A --- B --- 5A --- 5B --- 6A B A B A B A --- 9B --- 0A B A B A B A --- B --- A --- B --- 5A B A B A B A --- 8B --- 9A 9B 0A 0B CN (5) s with s (:) ( I/O points) XWZ-RO C- CN CN CN A B A B A B A --- B --- 5A --- 5B --- 6A B A B A B A --- 9B --- 0A --- 0B --- A B A B A B A --- B --- 5A --- 5B --- 6A B A B A B A --- 9B --- 0A --- 0B --- Tube CN FCN-67J0-AU/F * XGM-00-T (MIL connector) UL6 BC0P-SB AWG8(7/ 0.7) Interface cable ( color: Gray) * The connector is made by Fujitsu Component Ltd. CN A B CN CN and CN FCN-67J00-AU/FW * XGM-00-T (MIL connector) UL6 BC0P-SB AWG8(7/0.7) Interface cable color: Gray Tube color: XWZ-RI@C-@ CN, CN: Red XWZ-RO@C-@ CN, CN: Yellow * The connector is made by Fujitsu Component Ltd. 5

6 XWZ-R For Fujitsu connectors (6) s with s (:) (8 I/O points) XWZ-R C- - CN CN CN CN A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A 8B CN 8 A Tube B CN 8 FCN-67J056-AU/FW* XGM-00-T (MIL connector) UL6 BC0P-SB AWG8(7/0.7) Interface cable color: Gray Tube color: CN, CN, CN: Black CN * The connector is made by Fujitsu Component Ltd. 9 CN 0 CN CN, CN, and CN 6

7 XWZ-R For MIL connectors (7) s with s (:) (6 I/O points) XWZ-RO C CN CN (8) s with s (:) (6 I/O points) XWZ-RI C CN CN CN CN 9 0 CN and CN XGM-00-T (MIL connector) XGM-00-T (MIL connector) UL6 BC0P-SB AWG8(7/0.7) Interface cable ( color: Gray) 7

8 XWZ-R For MIL connectors (9) s with s (:) ( I/O points) XWZ-RO - -D CN CN CN (0) s with s (:) ( I/O points) XWZ-RI - -D CN CN CN () s with s (:) ( I/O points) XWZ-RI - -D CN CN CN CN Tube CN mch * CN m+ch * * For the XWZ-RI/O - -D XGM-00-T (MIL connector) XGM-00-T (MIL connector) UL6 BC0P-SB AWG8(7/0.7) Interface cable color: Gray Tube color: XWZ-RO@-@-D CN, CN: Yellow XWZ-RI@-@-D/D CN, CN: Red 8 CN CN and CN

9 XWZ-R For MIL connectors () s with s (:) (6 input points/6 output points) XWZ-RM - -D CN CN CN () s with s (:) (6 input points/6 output points) XWZ-RM - -D CN CN CN CN Tube CN CN XGM-00-T (MIL connector) XGM-00-T (MIL connector) CN CN and CN UL6 BC0P-SB AWG8(7/0.7) Interface cable color: Gray Tube color: XWZ-RM@-@-D XWZ-RM@-@-D CN: Red, CN: Yellow CN: Yellow, CN: Red 9

10 XWZ-R For Mitsubishi Electric PLCs () Mitsubishi Electric PLC Connecting s (:) ( input points) XWZ-RI C-MN CN CN CN A B --- A B --- A B A B 5A B A B A B A --- 8B --- 9A --- 9B --- 0A B A B A B A B A B A B A --- 6B --- 7A --- 7B --- 8A B A B A B Note: The G70V or G7TC connector pin numbers are not the same as the XWZ-R connector pin numbers. Refer to the datasheet for specific products for details. CN CN Tube (5) Mitsubishi Electric PLC Connecting s (:) ( output points) XWZ-RO C-MN CN CN CN A --- B --- A --- B --- A B A B 5A B A B A B A --- 8B --- 9A --- 9B --- 0A B A B A B A B A B A B A --- 6B --- 7A --- 7B --- 8A B A B A B Note: The G70V or G7TC connector pin numbers are not the same as the XWZ-R connector pin numbers. Refer to the datasheet for specific products for details. CN 0 A B FCN-67J00-AU/FW* XGM-00-T (MIL connector) CN CN and CN UL6 BC0P-SB AWG8(7/0.7) Interface cable color: Gray Tube color: XWZ-RI@C-MN CN, CN: Gray XWZ-RO@C-MN CN, CN: Black * The connector is made by Fujitsu Component Ltd. 0

11 XWZ-R Ratings and Specifications Rated current A Rated voltage 50 V Contact resistance 0 mω max. (at 0 mv, 00 ma max.) * Insulation resistance,000 MΩ min. (at 500 VDC) * Dielectric strength 500 VAC for min (leakage current: ma max.) Ambient operating temperature 0 to 80 C * These values are for the connectors. Safety Precautions Be sure to read Safety Precautions for All I/O Relay s in the website at: Warning Indications Precautions for Correct Use Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction, or undesirable effects on product performance. Precautions for Correct Use Wiring Do not perform wiring work, remove connectors, or connect connectors while power is being supplied. Electric shock or damage to the device may result. Double-check all wiring before turning ON the power supply. After wiring, route the cable so that force is not applied directly to the connections. Bending Radius of Connecting s To prevent damaging the Connecting s, use the following minimum bending radii as guidelines. Minimum bending radius Wiring diagram No. Model Minimum bending radius (mm) () XWZ-RY C 68 () XWZ-RA C 50 () XWZ-R C 68 () XWZ-RI C- (5) XWZ-RO C- 88 (6) XWZ-R C (7) XWZ-RO C (8) XWZ-RI C 68 (9) XWZ-RO - -D (0) XWZ-RI - -D () XWZ-RI - -D () XWZ-RM - -D 88 () XWZ-RM - -D () XWZ-RI C- -MN (5) XWZ-RO C- -MN Refer to the manuals for the connected PLC for the connections to I/O Units for OMRON PLCs. Series Model Man. No. Manual Name CS CSG-CPU H, CSH-CPU H W9 Programmable Controllers Operation Manual CJ CJH-CPU H-R, CJG/H-CPU H, CJG- CPU P, CJM-CPU, CJG-CPU W9 CJ Series Programmable Controllers Operation Manual CJ CJH-CPU6 -EIP, CJH-CPU6, CJM-CPU W7 CJ-series CJ CPU Unit Hardware User s Manual NJ NJ50- W500 NJ-series CPU Unit Hardware User's Manual NX NX-ID, NX-IA, NX-OD, NX-OC, NX-MD W5 NX-series Digital I/O Units User s Manual

12 MEMO

13 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, IIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGEE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.

14 OMRON AUTOMATION AMERICAS HEADQUARTERS Chicago, IL USA OMRON CANADA, I. HEAD OFFICE Toronto, ON, Canada OMRON ELECTRONICS DE MEXICO HEAD OFFICE México DF OMRON ELECTRONICS DE MEXICO SALES OFFICE Apodaca, N.L OMRON ARGENTINA SALES OFFICE Cono Sur OMRON CHILE SALES OFFICE Santiago OTHER OMRON LATIN AMERICA SALES OMRON ELETRÔNICA DO BRASIL LTDA HEAD OFFICE São Paulo, SP, Brasil OMRON EUROPE B.V. Wegalaan 67-69, NL- JD, Hoofddorp, The Netherlands. + (0) Authorized Distributor: Controllers & I/O Machine Automation Controllers (MAC) Motion Controllers Programmable Logic Controllers (PLC) Temperature Controllers Remote I/O Robotics Industrial Robots Mobile Robots Operator Interfaces Human Machine Interface (HMI) Motion & Drives Machine Automation Controllers (MAC) Motion Controllers Servo Systems Frequency Inverters Vision, Measurement & Identification Vision Sensors & Systems Measurement Sensors Auto Identification Systems Sensing Photoelectric Sensors Fiber-Optic Sensors Proximity Sensors Rotary Encoders Ultrasonic Sensors Safety Safety Light Curtains Safety Laser Scanners Programmable Safety Systems Safety Mats and Edges Safety Door Switches Emergency Stop Devices Safety Switches & Operator Controls Safety Monitoring/Force-guided Relays Control Components Power Supplies Timers Counters Programmable Relays Digital Panel Meters Monitoring Products Switches & Relays Limit Switches Pushbutton Switches Electromechanical Relays Solid State Relays Software Programming & Configuration Runtime G6-E-0 0/7 Note: Specifications are subject to change. 07 Omron. All Rights Reserved. Printed in U.S.A. Printed on recycled paper.

Cables for I/O Relay Terminals

Cables for I/O Relay Terminals s for I/O Relay s XWZ-R Connect I/O Relay s to I/O Units for Programmable Controllers with one touch. for G70V and G7TC I/O Relay s and G70D, G70A, and G70R Relay s. s with loose wires available with or

More information

Cables for I/O Relay Terminals

Cables for I/O Relay Terminals s for I/O Relay s XWZ-R Connect I/O Relay s to I/O Units for Programmable Controllers with one touch. for G70V and G7TC I/O Relay s, G70D and G70R Relay s, and G70A and P7TF-IS/OS I/O Sockets. s with loose

More information

E3X-DRT21/SRT21/CIF11

E3X-DRT21/SRT21/CIF11 for E3X-DA-N-series Fiber Amplifiers /SRT21/CIF11 CSM SRT21_CIF11_DS_E_3_2 Three New s for Fiber Amplifiers DeviceNet CompoBus/S RS-422 Note: Manufacture of the E3X-DA6-P will be discontinued in March

More information

S8VM Series Replacement Brackets

S8VM Series Replacement Brackets Original model Bottom mounting Front mounting Side mounting Original model: S8VM Replacement model: S8FS-G Replacement bracket Model scheduled to be discontinued Recommended replacement model Model Page

More information

Key-type Selector Switches

Key-type Selector Switches New Product Key-type Selector Switches ANK Keyed -mm Selector Switches Universal Design. Emphasis on Color Coding, Workability, and Safety. Easy to Use You can connect up to three Blocks in one stage for

More information

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm)

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm) CSM_PS-_S(R)_-31_DS_E_7_1 Separate s for Water Supply and Drainage Control in Buildings. Small, Lightweight s for Use as Built-in Components. The PS-@S(R) are separate s that allow the s to be withdrawn

More information

All Models Unless Indicated Safety Contacts: AC models MA-S2, 36 1 N/C MA-S20, S21 2 N/C DC models MA-S2, 34, 36 1 N/C MA-S20, S21, 35, 36 2 N/C

All Models Unless Indicated Safety Contacts: AC models MA-S2, 36 1 N/C MA-S20, S21 2 N/C DC models MA-S2, 34, 36 1 N/C MA-S20, S21, 35, 36 2 N/C R Safety Interlock Switches MA-S Series Stainless Steel Magnetically Actuated Safety Interlock Switches and Actuators Stainless steel cases both switch and actuator are housed in stainless steel for applications

More information

Mobile Robots TRANSFORMING MANUFACTURING AND LOGISTICS

Mobile Robots TRANSFORMING MANUFACTURING AND LOGISTICS Mobile Robots TRANSFORMING MANUFACTURING AND LOGISTICS 1 Mobile Robots Transforming manufacturing and logistics Modernize Your Workflow Omron mobile robots are Autonomous Intelligent Vehicles (AIVs) designed

More information

Zero cross function. DIN track mounting *2. Screw mounting

Zero cross function. DIN track mounting *2. Screw mounting Solid State Contactors for Heaters Three-phase CSM_Three-phase_DS_E_3_1 Compact, Slim-profile SSRs with Heat Sinks. Solid State Contactors for Three-phase Heaters Reduced Installation Work with DIN Track

More information

0.3 A max., fuse externally 0.2 A quick acting Internal Fuse: AC models 2 A fast acting

0.3 A max., fuse externally 0.2 A quick acting Internal Fuse: AC models 2 A fast acting R Safety Interlock Switches MA Series Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic to satisfy most application

More information

Push-In Plus Terminal Block Sockets

Push-In Plus Terminal Block Sockets New Product Push-In Plus Terminal Block Sockets PYF-@@-PU/P2RF-@@-PU Sockets with Push-In Plus Terminal Blocks Reduce Wiring Time for Relays and Timers Wiring time is reduced by 60%* in comparison with

More information

Phase-sequence Phase-loss Relay

Phase-sequence Phase-loss Relay Phase-sequence Phase-loss Relay K8AK-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Greater resistance to inverter noise. Distinguishes between correct phases, phase sequence,

More information

Mounting Brackets [Refer to Dimensions on page 6.]

Mounting Brackets [Refer to Dimensions on page 6.] Mounting Brackets E-L Slits/Reflectors E-S/E-R CSM_E-L/E-S/E-R_DS_E Mounting Brackets [Refer to Dimensions on page.] Model Fitting materials Count E-L Iron, zinc plating E-L0 Iron, zinc plating E-L Iron,

More information

E39-R3. Reflectors for photoelectric sensors. Ordering information

E39-R3. Reflectors for photoelectric sensors. Ordering information Reflectors for photoelectric sensors E39-R The E39-R series of reflectors for photoelectric sensors features a wide range of models with different sizes, shapes, types and materials. The reflectors provide

More information

Sensors Temperature, Humidity, Light, Barometric pressure, Sound noise, 3-axis acceleration *1, etvoc *2

Sensors Temperature, Humidity, Light, Barometric pressure, Sound noise, 3-axis acceleration *1, etvoc *2 Sense a variety of environmental information Connects to a network via USB or Bluetooth to enable the sending of measurement data Using OMRON s unique and innovative algorithm, enables highly accurate

More information

Ordering Information. Conductive Level Controller 61F-GP-N2. Accessories (Order Separately) Selection Guide for Electrode Holders and Separators

Ordering Information. Conductive Level Controller 61F-GP-N2. Accessories (Order Separately) Selection Guide for Electrode Holders and Separators Conductive Level Controller Cat. No. N43I-E-01 Automatic Water Supply and Drainage Control Ideal for level control of any conductive liquid. Compact plug-in controller for single- or two-point control

More information

2JCIE-BL. Sense a variety of environmental information. Model Number Structure. Ordering Information. Specifications. Environment Sensor.

2JCIE-BL. Sense a variety of environmental information. Model Number Structure. Ordering Information. Specifications. Environment Sensor. Sense a variety of environmental information Includes six sensors, wireless functionality, and built-in battery Adopts Bluetooth low energy beacon technology for simple construction of a 1:n sensor network

More information

Original instructions JSNY7 Magnetic switch

Original instructions JSNY7 Magnetic switch Original instructions JSNY7 Magnetic switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.jokabsafety.com Read and understand this document Please read and understand this

More information

OptoLum MegaLine RGBW Luminaire

OptoLum MegaLine RGBW Luminaire OptoLum MegaLine RGBW Luminaire Getting Started OptoLum MegaLine RGBW Luminaires offer indoor cove lighting and wall washing in a compact linear form. This guide contains important information on planning,

More information

Packaging Machine Control Solutions. An electronic cam brings innovation to your packaging machines

Packaging Machine Control Solutions. An electronic cam brings innovation to your packaging machines Packaging Machine Control Solutions An electronic cam brings innovation to your packaging machines 2 Packaging Machine Control Solutions Craftsmanship at your finger tips Easily implement an electronic

More information

Operating pressure Atmospheric pressure 1.96 MPa (See note 2.) 981 kpa (See note 2.) General applications for purified water and wastewater

Operating pressure Atmospheric pressure 1.96 MPa (See note 2.) 981 kpa (See note 2.) General applications for purified water and wastewater Electrode Holder BF-@(R)/(T) Complete Lineup for Use in Hightemperature, High-pressure Environments or Where Exposed to Chemicals The BF-1 is ideal for liquids with low specific resistance, such as wastewater.

More information

RL4050LS. Electronic Load Shackle. Installation Guide

RL4050LS. Electronic Load Shackle. Installation Guide RL4050LS Electronic Load Shackle Installation Guide 1 70997 Contents 1. Introduction... 1 2. General Installation of the Load Shackle... 2 3. Load Cell Wiring... 2 4. Load Shackle Specifications... 3 5.

More information

3M D Sub Socket 50 Position 8350 Series

3M D Sub Socket 50 Position 8350 Series M D Sub Socket 50 Position 850 Series IDC compatible Lower insertion/withdrawal force than other 50 position products Available in either open or closed end cover Mounting options include #4-40 UNC or

More information

Ordering Information. Conductive Level Controller 61F-GP-N2. Accessories (Order Separately) Selection Guide for Electrode Holders and Separators

Ordering Information. Conductive Level Controller 61F-GP-N2. Accessories (Order Separately) Selection Guide for Electrode Holders and Separators Conductive Level Controller CSM DS_E_1_ Automatic Water Supply and Drainage Control Ideal for level control of any conductive liquid. Compact plug-in controller for single- or two-point control of conductive

More information

3M Molded Socket for.050 Pitch Cable, Cable Assembly Connector 871 Series

3M Molded Socket for.050 Pitch Cable, Cable Assembly Connector 871 Series 3M Molded Socket.100.100 for.050 Pitch Cable, Cable Assembly Connector 871 Series Part of a complete cable assembly Mates with industry standard 0.025 inch square contacts on.100 inch x.100 inch centers

More information

Wash Down Duty Non-Contact Sensor

Wash Down Duty Non-Contact Sensor Wash Down Duty Non-Contact Sensor Instruction Manual Models WDDC1-020/040/060/080/100 WDDC2-020/040/060/080/100 WDDV1-020/040/060/080/100 WDDV2-020/040/060/080/100 Table of Contents 1. General Description.....................................

More information

Iron, zinc plating. (with spring and plain washers) Nuts M4 Iron, zinc plating 2

Iron, zinc plating. (with spring and plain washers) Nuts M4 Iron, zinc plating 2 Mounting Brackets E-L/F-L Slits/Reflectors E-S/E-R CSM_E-L_F-L_E-S_E-R_DS_E Mounting Brackets Model Fitting materials Count E-L Iron, zinc plating Accessories Applicable sensor Page (mounting pitch on

More information

H8SX/1650 Series E6000H TFP-120 User System Interface Board User s Manual HS1650ECN61H

H8SX/1650 Series E6000H TFP-120 User System Interface Board User s Manual HS1650ECN61H H8SX/1650 Series E6000H TFP-120 User System Interface Board User s Manual HS1650ECN61H Rev.3.00 2003.10.6 Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum

More information

Festoon Manual Stretch Wire

Festoon Manual Stretch Wire Festoon Manual Stretch Wire 1 961000.3.0 14.12.16 STRETCHED WIRE FESTOON MANUAL CONDUCTIX INCORPORATED The technical data and images which appear in this manual are for informational purposes only. NO

More information

3M Ground Plane Cable.050" 28 AWG Stranded, One Drain, PVC 3476 Series

3M Ground Plane Cable.050 28 AWG Stranded, One Drain, PVC 3476 Series M Ground Plane Cable.050" 28 AWG Stranded, One Drain, PVC 476 Series 28 AWG wire on.050 inch centers permits mass termination to a broad line of IDC connectors Ground plane construction for increased signal

More information

Pallet Safe: Installation Supplement Rev

Pallet Safe: Installation Supplement Rev Pallet Safe: Installation Supplement Rev. 4-1-13 Smartscan Incorporated, 33083 Eight Mile Road, Livonia MI 48152 Tel: (248)477-2900 Fax: (248) 477-7453 Web: www.smartscaninc.com SMARTSCAN INCORPORATED

More information

Touch Finder. Standard Ethernet Cables (RJ-45 of the FCC regulations) Standard Ethernet Cables (RJ-45 of the FCC regulations)

Touch Finder. Standard Ethernet Cables (RJ-45 of the FCC regulations) Standard Ethernet Cables (RJ-45 of the FCC regulations) Code CSM DS_E_1_1 Read Barcodes or 2D Codes from everything from paper labels to metal, plastic, or glass surfaces. Read direct markings. Stably read codes from moving objects over a wide field of view.

More information

RSD250 Unwind Dancer Package WEB CONTROL PRODUCTS FORM NO. L B User Manual. MTY (81)

RSD250 Unwind Dancer Package WEB CONTROL PRODUCTS FORM NO. L B User Manual. MTY (81) WEB CONTROL PRODUCTS User Manual RSD250 Unwind Dancer Package FORM NO. L-279-B-003 FORM NO. L-279-B-003 In accordance with Nexen s established policy of constant product improvement, the specifications

More information

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved. XBDM-HW63 63A Model User & Installation Manual www.xpcc.com 2016. All rights reserved. (Rev 3/02/16) Table of Contents Introduction...3 Product Overview... 3 Installation and Operation...4 Inspection...4

More information

TL-600 MOBILE PHASE HEATER

TL-600 MOBILE PHASE HEATER TL-600 MOBILE PHASE HEATER INSTRUCTION MANUAL Timberline Instruments, Inc. 1880 S. Flatiron Ct., Unit I Boulder, Colorado 80301 Ph: (303) 440-8779 Fx: (303) 440-8786 info@timberlineinstruments.com www.timberlineinstruments.com

More information

3M Scotchlok Copper Compression Lugs, and Series

3M Scotchlok Copper Compression Lugs, and Series Copper Compression s, 30000 and 31000 Series Data Sheet June 2011 Description Copper Compression s are one-piece, seamless copper and are designed to cover a wide range of conductor sizes. They are available

More information

USER MANUAL MODEL 1019 and 1019S DB-9 Async. Short Range Modem With Transformer Isolation

USER MANUAL MODEL 1019 and 1019S DB-9 Async. Short Range Modem With Transformer Isolation USER MANUAL MODEL 1019 and 1019S DB-9 Async. Short Range Modem With Transformer Isolation C E R T I F I E D An ISO-9001 Certified Company Part# 07M1019-C Doc# 051021UC Revised 06/03/99 SALES OFFICE (301)

More information

Distributed by: www.jameco.com 1-800-81-4242 The content and copyrights of the attached material are the property of its owner. M Wiremount Socket.100.100 for.050 Pitch Cable 891 Series Preassembled, terminates

More information

J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL

J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL Revision 1.01 1 Introduction...2 1.1 Firmware Revision...2 1.2 Product Features...2 2 Installation...3 2.1 Unpacking the box...3 2.2 Mounting the

More information

Agilent 16047D Test Fixture

Agilent 16047D Test Fixture Agilent 16047D Test Fixture Operation and Service Manual Third Edition Agilent Technologies Japan, Ltd. Agilent PN 16047-90300 May 2000 Printed in Japan Notices The information contained in this document

More information

Omron Robotic Automation Complete automation expertise

Omron Robotic Automation Complete automation expertise Omron Robotic Automation Complete automation expertise 2 Omron Robotic Automation Omron Robot Solution Flexible manufacturing enabled by a seamless integration of Robots and Machine Control Omron s unique

More information

Figure 1 Input power cable (left) and output power cable (right)

Figure 1 Input power cable (left) and output power cable (right) TIDA-00282 Cable Assemblies These cable assemblies are intended for use with the C2000-based Automotive Digitally-controlled Boost Power Supply board described in TI Designs TIDA-00282. Figure 1 Input

More information

3M Eurosocket Type C (Rows A & C or A, B & C Filled)

3M Eurosocket Type C (Rows A & C or A, B & C Filled) DIN 41612 compatible High density (64 & 96 position) Mates with DIN 41612 Type C headers High reliability contact design Can be daisy-chained or end terminated to flat cable Optional strain relief with

More information

3M Medium-Wall Heat Shrink Tubing IMCSN

3M Medium-Wall Heat Shrink Tubing IMCSN 3M Medium-Wall Heat Shrink Tubing IMCSN Data Sheet November 2017 Product Description 3M Medium-Wall Heat Shrink Tubing IMCSN is designed to provide reliable performance for electrical splices, connections,

More information

3M Medium-Wall Heat Shrink Tubing IMCSN

3M Medium-Wall Heat Shrink Tubing IMCSN 3M Medium-Wall Heat Shrink Tubing IMCSN Data Sheet April 2017 Product Description 3M Medium-Wall Heat Shrink Tubing IMCSN is designed to provide reliable performance for electrical splices, connections,

More information

3M Round, Shielded/Jacketed, Disc. Wire Cable 26 AWG Solid, Twisted Pair, PVC/PVC 3560 Series

3M Round, Shielded/Jacketed, Disc. Wire Cable 26 AWG Solid, Twisted Pair, PVC/PVC 3560 Series M Round, Shielded/Jacketed, Disc. Wire Cable 26 AWG Solid, Twisted Pair, PVC/PVC 560 Series Twisted pairs reduce crosstalk for balanced drive applications Dual shielding provides 5 db average shielding

More information

Instructions and E00 Series Sampling Module Extenders

Instructions and E00 Series Sampling Module Extenders Instructions 012-1568-00 and 012-1569-00 80E00 Series Sampling Module Extenders 071-0436-01 www.tektronix.com 071043601 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by

More information

Daniel Orifice Fittings and Meter Tubes

Daniel Orifice Fittings and Meter Tubes Installation and Operating Instructions P/N 3-9008-002, Rev E November 2017 Daniel Orifice Fittings and Meter Tubes Specific to the Pressure Equipment Directive Flow Lifecycle Services for Daniel products

More information

3M D Sub EMI Junction Shell Metalized Plastic

3M D Sub EMI Junction Shell Metalized Plastic M D Sub EMI Junction Shell Metalized Plastic Protection from EMI/ESD Easy assembly reduces time and labor to ensure low applied cost Light weight, compact design Strain relief compensates for multiple

More information

P1902 Installation Manual

P1902 Installation Manual P1902 Installation Manual Precision Lighting Controller P1902-JRev. 1.0 2010 Profile Systems, LLC 1000 E. 80 th Place Suite 777 South Merrillville, IN 46410 (800) 898-5483 www.profilesystems.com Revision

More information

NECTOR M Power System Building and Luminaire Power

NECTOR M Power System Building and Luminaire Power Building and Luminaire Power Buildings are alive. They talk. They breath. They have the intelligence to sense and react, anticipate and illuminate. With increased urbanization and a rise in environmental

More information

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features INSTRUCTION SHEET T1000 Transformer for Magnetic-Field Susceptibility Testing Features Up to 100 A RMS secondary current Exceeds AF Magnetic Field test requirements of DO 160 Section 19 and Boeing D6-16050-5

More information

DUST FREE ACTIVE Total Home Air Purification

DUST FREE ACTIVE Total Home Air Purification DUST FREE ACTIVE Total Home Air Purification Installation & Operation Manual This manual covers the following models: DF ACTIVE 6" - #13070 DF ACTIVE 12" - #13071 GENERAL This device is designed to be

More information

END TRUCKS WHEEL SIZES: 9", 12", 15" & 18"

END TRUCKS WHEEL SIZES: 9, 12, 15 & 18 OPERATION, SERVICE & PARTS MANUAL STRUCTURAL TUBE ROTATING AXLE WHEEL SIZES: 9", ", 5" & 8" P/N: 5367 REV. AA November 03 ROTATING TOP AXLE RUNNING END ROTATING TRUCK PARTS AXLE BREAKDOWN END TRUCK P/N:

More information

3M Cold Shrink Silicone Rubber Connector Insulators 8440 Series

3M Cold Shrink Silicone Rubber Connector Insulators 8440 Series 3M Cold Shrink Silicone Rubber Connector Insulators 8440 Series Data Sheet May 2014 Product Description 3M Cold Shrink Connector Insulators 8440 Series are open-ended, silicone rubber, tubular sleeves.

More information

3M Pleated Foil Shielded Cable.025" 30 AWG Solid, TPE Primary, PVC Jacket, Low Skew Series

3M Pleated Foil Shielded Cable.025 30 AWG Solid, TPE Primary, PVC Jacket, Low Skew Series 3M Pleated Foil Shielded Cable.025" 30 AWG Solid, TPE Primary, PVC Jacket, Low Skew 93101 Series Skew of less than 100 picoseconds/meter when terminated in unbalanced mode, with even wire signals (excluding

More information

Instructions for Use Reusable Ablation Catheter Cables

Instructions for Use Reusable Ablation Catheter Cables Processed by Instructions for Use Reusable Ablation Catheter Cables STERILE Explanation of Symbols Federal Law in the USA restricts this device to sale by or on the order of a physician Sterilized by Ethylene

More information

Model 3185E DUAL TONE DECODER INSTRUCTION MANUAL

Model 3185E DUAL TONE DECODER INSTRUCTION MANUAL Model 3185E DUAL TONE DECODER INSTRUCTION MANUAL Monroe Electronics 100 Housel Ave Lyndonville NY 14098 phone 585-765-2254 fax 585-765-9330 monroe-electronics.com Printed in USA Copyright Monroe Electronics,

More information

3M PCB Connector.100 Four Row 3400 Series

3M PCB Connector.100 Four Row 3400 Series PCB Connector.00 Four Row 300 Series Low profile Standard staggered grid Variety of pin lengths and plating options available See Regulatory Information Appendix (RIA) for chemical compliance information

More information

Adjustable Fused Power Supply

Adjustable Fused Power Supply User & Installation Manual EN Adjustable Fused Power Supply 7-20V 3A P010-52 Contact & Product mo-vis BVBA Biebuyckstraat 15 D 9850 Nevele - Belgium Website: www.mo-vis.com E-mail: contact@mo-vis.com Telephone:

More information

Signal Follower Card. Instruction Manual Model C

Signal Follower Card. Instruction Manual Model C Signal Follower Card Instruction Manual Model C10032-000 Table of Contents General Description... 2 Features... 3 Typical Applications....3 Specifications... 3 Adjustment Procedure... 4 Prints... 5 Standard

More information

Agilent 16048D Test Leads

Agilent 16048D Test Leads Agilent 16048D Test Leads Operation and Service Manual Fourth Edition Agilent Technologies Japan, Ltd. Agilent PN 16048-90031 May 2000 Printed in Japan Notices The information contained in this document

More information

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Document No. 1800-56 Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:

More information

Contents CONTACT INFORMATION... 2

Contents CONTACT INFORMATION... 2 Contents CONTACT INFORMATION... 2 1. Introduction... 3 2. Technical specifications... 4 3. Installation of transponder... 5 4. installation of driver-id selector... 7 5. GUARANTees & Warranties... 8 Contact

More information

APC Step-Down Transformer. Models: AP9626, AP9627, and AP9628

APC Step-Down Transformer. Models: AP9626, AP9627, and AP9628 User Manual English APC Step-Down Transformer Models: AP9626, AP9627, and AP9628 990-7820F 06/2006 Introduction Introduction The APC step-down transformers are used to convert a higher input voltage (208-200

More information

Drag Chain Conveyor Installation and Operation Manual

Drag Chain Conveyor Installation and Operation Manual Drag Chain Conveyor Installation and Operation Manual Material Handling Equipment Sales, Incorporated 310 S. Section Line Rd Delaware, OH 43015 Phone: (989) 430-4005 Fax: (740) 363-9004 WARRANTY MATERIAL

More information

3M Eurosocket Type C (Rows A & C, A & B or A, B & C Filled)

3M Eurosocket Type C (Rows A & C, A & B or A, B & C Filled) DIN 41612 compatible High density (64 & 96 position) Mates with DIN 41612 Type C headers High reliability contact design Can be daisy-chained or end terminated to flat cable Optional strain relief with

More information

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER 4-20 ma input 1 V drop (4 V with Backlight) 3½ Digits LCD, 1" High Loop-Powered Backlight Option HART Protocol Transparent Plastic NEMA 4X, IP65 Enclosure

More information

OWNER S MANUAL. Model 845. RFV Dye Marking System /15

OWNER S MANUAL. Model 845. RFV Dye Marking System /15 OWNER S MANUAL Model 845 RFV Dye Marking System 845-15 5/15 HARVEST TEC 845 TABLE OF CONTENTS PAGE INTRODUCTION & TOOLS NEEDED 3 INSTALLATION OF DYE SPAYER TANK ASSEMBLY 4 DYE SPRAYER SYSTEM WIRING DIAGRAMS

More information

Dancer Duty Potentiometer

Dancer Duty Potentiometer Dancer Duty Potentiometer Instruction Manual Model DDP01-K010 Model DDPS1-K010 Model DDP01-K005 Model DDPS1-K005 Model DDP02-K010 Model DDPS2-K010 Model DDP02-K005 Model DDPS2-K005 Table of Contents 1.

More information

3M Round, Jacketed, Flat Cable.050" 28 AWG Stranded, Mass-Term, PVC/PVC 3759 Series

3M Round, Jacketed, Flat Cable.050 28 AWG Stranded, Mass-Term, PVC/PVC 3759 Series M Round, Jacketed, Flat Cable.050" 28 AWG Stranded, Mass-Term, PVC/PVC 759 Series Round construction permits easier routing 28 AWG wire on.050 inch centers permits mass termination to broad line of IDC

More information

3M Wiremount Socket Position for.050 Pitch Cable 79 Series

3M Wiremount Socket Position for.050 Pitch Cable 79 Series 3M Wiremount Socket.100.100 64 Position for.050 Pitch Cable 79 Series Standard profile plastic strain relief Mates with 3M headers, plugs, and pin strips for quick connect/disconnect capability Centerbump

More information

Thin Film Platinum RTDs. HRTS Series. Datasheet

Thin Film Platinum RTDs. HRTS Series. Datasheet Thin Film Platinum RTDs HRTS Series Datasheet Thin Film Platinum RTDs The HRTS Series Thin Film Platinum RTDs (Resistance Temperature Detectors) are designed to measure temperatures from -70 C to 260 C

More information

Daniel TM Ultrasonic Flow Meters

Daniel TM Ultrasonic Flow Meters Installation and Operating Instructions Manual Part Number 3-9000-745 Revision F August 2017 Daniel TM Ultrasonic Flow Meters Installation and Operating Instructions Specific to the Pressure Equipment

More information

5020 SERIES HERMETICALLY SEALED THERMOSTAT PROBE

5020 SERIES HERMETICALLY SEALED THERMOSTAT PROBE 5020 SERIES HERMETICALLY SEALED THERMOSTAT PROBE Introduction The 5020 series is a single throw, snap-action, hermetically sealed temperature control designed for applications requiring high vibrational

More information

Instructions for Use Reusable Electrophysiology Catheter Cables

Instructions for Use Reusable Electrophysiology Catheter Cables Processed by Instructions for Use Reusable Electrophysiology Catheter Cables STERILE Explanation of Symbols Federal Law in the USA restricts this device to sale by or on the order of a physician Sterilized

More information

3M Round Conductor Flat Cable.025" 30 AWG Stranded, PVC 3754 Series

3M Round Conductor Flat Cable.025 30 AWG Stranded, PVC 3754 Series M Round Conductor Flat Cable.025" 0 AWG Stranded, PVC 754 Series Close spacing permits higher signal density PVC insulation provides excellent flexibility 0 AWG stranded on.025 inch spacing allows for

More information

Agilent 16034E Test Fixture

Agilent 16034E Test Fixture Agilent 16034E Test Fixture Operation and Service Manual Third Edition Agilent PN 16034-90041 December 1999 Printed in: Japan Notices The information contained in this document is subject to change without

More information

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N Thermoelectric Coolers All Models INSTRUCTION MANUAL Rev. G 2016 Pentair Equipment Protection P/N 89072602 89072603 TABLE OF CONTENTS RECEIVING THE THERMOELECTRIC COOLER...3 HANDLING & TESTING THE THERMOELECTRIC

More information

SelfCheck System R-Series. Site Planning Guide

SelfCheck System R-Series. Site Planning Guide SelfCheck System R-Series Site Planning Guide Copyright 2006 2007, 3M. All rights reserved. SelfCheck System R-Series Site Planning Guide 78 8129 2082 1 Rev. C 3M, Tattle-Tape, and SelfCheck are trademarks

More information

CMT MANUAL 1.2 TERMS AND CONDITIONS

CMT MANUAL 1.2 TERMS AND CONDITIONS CMT MANUAL 1.2 TERMS AND CONDITIONS TABLE OF CONTENTS INDEMNITY... 3 DOCUMENT INFORMATION... 3 ACKNOWLEDGEMENTS... 3 1.2.1 TERMS AND CONDITIONS OF SALE... 4 1.2.1.1 PRICE... 4 1.2.1.2 OWNERSHIP... 4 1.2.1.3

More information

Process Returns in VOTW

Process Returns in VOTW Process Returns in VOTW 1. From the Menu bar, select Other Functions Returns. 2. From the Returns Action list, select one of the following: Add a Claim Request: Request a new return on an Eaton product.

More information

Thermoelectric Cooler

Thermoelectric Cooler INSTRUCTION MANUAL Thermoelectric Cooler TE090624020, TE121024020, TE121048020, TE162024020, TE162048020, TE090624010, TE121024010, TE121048010, TE162024010, TE162048010, TE090624011, TE121024011, TE162024011

More information

CFL Series User Manual

CFL Series User Manual CFL SERIES Continuous Level Transmitter CFL Series User Manual Quick Start Guide TM Please read this manual carefully before using product CFL Series Sensor Manual Heavy Duty Industrial Level Transmitter

More information

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web:   IMPORTANT!!! 10810 W. LITTLE YORK RD. #130 - HOUSTON, TX 77041-4051 VOICE (713) 973-6905 - FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN

More information

ISIMET. E Series Enclosure. Custom Assemblies Installation, Maintenance, and Operation Instructions

ISIMET. E Series Enclosure. Custom Assemblies Installation, Maintenance, and Operation Instructions ISIMET E Series Enclosure Custom Assemblies Installation, Maintenance, and Operation Instructions The Custom Assembled E-Series Enclosures is pre-assembled and pre-wired enclosure intended for use with

More information

Royal Sovereign RSL 2701 Laminator

Royal Sovereign RSL 2701 Laminator Royal Sovereign RSL 2701 Laminator Instruction Manual Provided By http://www.mybinding.com http://www.mybindingblog.com TABLE OF CONTENTS Introduction -----------------------------------------------------------------------------------

More information

3M Mini D Ribbon (MDR) Connectors.050 Boardmount Through-Hole Right Angle Receptacle - Shielded 102 Series

3M Mini D Ribbon (MDR) Connectors.050 Boardmount Through-Hole Right Angle Receptacle - Shielded 102 Series M Mini D Ribbon (MDR) Connectors.050 Boardmount Through-Hole Right Angle Receptacle - Shielded 102 Series Wiper-on-wiper contact for reliable repetitive plugging Surface mount compatible PCT insulator

More information

3M I/O Interconnect System 2.0 mm for IEEE 1394

3M I/O Interconnect System 2.0 mm for IEEE 1394 M I/O Interconnect System 2.0 mm for IEEE 194 Shell Kit for Receptacle E06 Series Complete shell kit for M 2.0 mm I/O Interconnect System for IEEE 194 Wiremount Receptacle (TS-2296) Includes outer body,

More information

General Safety Information

General Safety Information TM General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2 FALCON ELECTRIC INC. OWNER S MANUAL SG Series Maintenance Bypass Option 1KVA 3KVA MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2 OM48030 Rev. B 01/17/03 FALCON Electric Inc., 5106 Azusa Canyon Road,

More information

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved. For more information, visit www.247technology.com/on-line-ups/c60-standby-ups C60 Standby UPS 800VA Models User & Installation Manual 2015. All rights reserved. (Rev 6/23/15) Table of Contents Package

More information

3M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series

3M Round, Shielded/Jacketed, Flat Cable.050 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 659 Series Round construction permits easier routing 28 AWG wire on.050 inch pitch permits mass termination to broad

More information

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain Installation, Operating and Maintenance Instructions Incognito Series Air Curtain Models: INC10036, INC10042, INC10048, INC10064, INC10072, INC10084, INC10096, INC10108, INC10120, INC10144. READ THIS OWNER

More information

3M Link Connector.100" Boardmount, Straight and Right Angle 382 Series

3M Link Connector.100 Boardmount, Straight and Right Angle 382 Series 3M Link Connector.100" Boardmount, Straight and Right Angle 382 Series Mates with 3M Wiremount Link Connector 38104 Vertical or right angle configuration Accepts latch mechanism of Wiremount Link Connector

More information

3M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series

3M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series 3M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series Wiper-on-wiper contact for reliable repetitive plugging Ultra-low signal skew for high data rate transmission

More information

3M Heavy Wall Heat Shrink Tubing ITCSN

3M Heavy Wall Heat Shrink Tubing ITCSN 3M Heavy Wall Heat Shrink Tubing ITCSN Data Sheet September 2013 Description 3M Heavy Wall Heat Shrink Tubing ITCSN is designed to provide reliable performance for electrical splices, connections, and

More information

PalletPal Low Profile Disc Turntable

PalletPal Low Profile Disc Turntable OWNER S MANUAL PalletPal Low Profile Disc Turntable Model # Serial # Date placed in Service SOUTHWORTH PRODUCTS CORP P.O. Box 1380 Portland, ME 04104-1380 Telephone: (207) 878-0700 or (800) 743-1000 Fax:

More information

Installation Instructions

Installation Instructions Installation Instructions This document should be printed and readily available at the installation site. QDuct is a userfriendly system that will save installation time and labor. Installation videos,

More information

Pallet Puller. Owner s Manual

Pallet Puller. Owner s Manual Pallet Puller Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result

More information