Ordering Information. Conductive Level Controller 61F-GP-N2. Accessories (Order Separately) Selection Guide for Electrode Holders and Separators

Size: px
Start display at page:

Download "Ordering Information. Conductive Level Controller 61F-GP-N2. Accessories (Order Separately) Selection Guide for Electrode Holders and Separators"

Transcription

1 Conductive Level Controller CSM DS_E_1_ Automatic Water Supply and Drainage Control Ideal for level control of any conductive liquid. Compact plug-in controller for single- or two-point control of conductive liquid level. 4/110/10/0/30/40 VAC operation possible. Easy installation on DIN rail. Low voltage (AC) electrodes. Full surge protection. 0 VAC 0 VAC Ordering Information Compact plug-in conductive level controller When placing your order, be sure to specify the desired operating voltage. Example: 10 VAC Rated supply voltage Accessories (Order Separately) Selection Guide for Electrode Holders and Separators Electrode Holders Applications Electrode Separators For city water and other general-use electrodes. Easy-to-replace separate versions facilitate maintenance of electrodes. When mounting space is limited. Special 3-pole holder of small size and light weight. Ideal for soft drink vendors, etc., where only limited space is available. For low specific liquids. Used for sewage, sea water, etc., having a low specific resistance. In sewage use, electrode holders must be installed 10 to 0 cm apart from one another. For acids, alkalis and sea water, electrode holders may be as much as 1 meter apart to operate properly. When resistance to high pressure is required. Ideal for use in tanks where temperature or pressure inside the tank is high, e.g. 50 C Mounting style Flange Screw Flange Screw Insulator material Phenol resin Phenol resin Ceramics Fluorine Resin Max. temperature 70 C (without water drips 150 C (without water drips or vapour on 50 C (without water or vapour on the surface of the surface of the electrode holder) the electrode holder) drips or vapour on the surface of the electrode holder) No. of electrodes BF-1 BS-1 3 PS-3S PS No. of electrodes Model 1 F P 3 F P 1

2 Selection Guide for Electrodes, Connecting and Lock Nuts Applicable liquids Material Models for individual electrode assembly components Electrode (1m long) Connecting nut Lock nut Model Indication mark Model Inscription Model Inscription Purified city water, industrial water, sewage Purified city water, industrial water, sewage, dilute alkaline solution SUS-304 (AISI-304) SUS316 (AISI-316) F03-01-SUS304 1 line F03-0-SUS F03-03-SUS F03-01-SUS316 lines F03-0-SUS316 6 F03-03-SUS316 6 Application Example Level control in tanks, reservoirs, sewage plants, underground wells, mixing plants etc. Level control for element protection in pipes, channels, and irrigation systems. Flow detection in pipes, channels, and irrigation systems. Ice bank control in cold drink dispensers, ice makers, water chillers, bulk milk tanks, etc. Dispensing of liquids by volume. Indication of liquid buildup due to filter blockages. Pollution/foul water detection for rivers, drains, etc. Alarm control warning of abnormal or dangerously high or low levels. Specifications Supply voltage Operating voltage range Interelectrode voltage * Power consumption Operate resistance Release resistance Response time Control output Insulation resistance *Secondary voltage of transformer 4, 110, 10, 0, 30, 40 VAC; 50/60 Hz 85% to 110% of rated voltage 8 VAC Approx. 3. VA Approx. 4 KΩ min. Between electrode and E3 Approx. 15 KΩ max. Between electrode E and E3 Operate: 80 ms max., Release: 160 ms max. 10 A, 50 VAC (at 40 C) 3 A, 50 VAC (at 55 C) 100 MΩ max. (at 500 VDC) between power terminals and electrode terminals, and between electrode terminals and contact terminals Dielectric strength,000 VAC, 50/60 Hz for 1 min., between power terminals and electrode terminals, and between electrode terminals and contact terminals Ambient temperature Operating: 10 C to 55 C Ambient humidity Operating: 45% to 85% Life expectancy Mechanical: 10,000,000 operations min. Weight Approx. 190 g

3 Connections Automatic Water Supply and Drainage Control 1. Water supply Connect electromagnetic switch coil terminal A to Tb. The pump stops when the water level reaches and starts when the water level drops below E.. Drainage Connect the electromagnetic switch coil terminal A to Ta. The pump starts when the water level reaches and stops when the water level drops below E. Note: 1. The diagram shows the connections for water supply. When draining, change the connection Tb to Ta.. The earth terminal must be grounded. Power source R S T 0 or 40 VAC MCCB Tc S 6 Ta S1 Tb 7 E3 E 1 8 Electromagnetic switch A Earth M P Stop Start E Tank E3 Reservoir Operation The conductive type level controller consists of a plug-in controller connected to a set of stainless steel probes. These are cut to length and inserted vertically into the liquid. A low voltage is applied between these probes and the earth probe (or tank, if it is electrically conductive). The water provides a current between the earth probe and the high-level probe. The output relay in the controller is energized when the water level reaches the high-level probe and de-energized when the water level falls below it. For two-point control a low-level probe is used as well. In this case the relay does not de-energize until the water level falls below the low-level probe. Using the low-level probe allows a wide differential between switching a pump on and off, and can avoid excessive pump operation during tank emptying or filling. If this differential is not required, the low-level probe need not be connected. Dimensions Note: All units are in millimeters unless otherwise indicated F- GP-N PF083A 3

4 Electrode Holders PS-3S PF parallel thread 9-dia. rubber (effective dia.: ) bushing (inner) 80 9 PS-3S/-3SR PS-4S/-4SR PS-5S/-5SR 34 dia. E E3 E E3 E E3 E4 E Mounting Holes Screw Holes Used with coupling Used with mounting bracket PF 65 dia. hole PS PF1/ Parallel thread 11-dia. Mounting Holes Dust preventive rubber cap (optional) BF-1 BS-1(S) φ4 Rubber 6 Electrode packing SUS dia. M3 3 l* * Standard holder construction includes three integral 300 mm length electrodes. However, a type having 1,000 mm length electrodes is available on request dia. BS-1 Terminal bolt SUS01 (M6) Nut (M6) Terminal bolt SUS304 (M4) P= (49) 7 Cast iron Two M5 x 5 mounting screws 0-dia Width across flats: 0 M18 P=1.5 Two M4 P=0.7 PF1/ 6-dia. hole 48 Two, 6-dia. holes 4-dia. BS-1S BS-1S1 BS-1S Terminal bolt SUS304 (M4) P=0.7 Nut (iron) Width across flats: 0 M18 P=1.5 Two, M4 P=0.7 M18 P=1.5 (fine screw thread) 4 dia M18 P=1.5 (fine screw thread) 4

5 Electrode Separators F P (for Single Pole) F P (for Three Poles) 6.5-dia. Three 7-dia. 8-dia. 41-dia. Precautions How to Mount Electrodes Connecting Electrodes to Electrode Holders Electrode holder Connecting One Electrode to Another Electrode Connecting nut Clamp screw 3. Tighten the electrode with the two clamp screws. Lock nut Spring washer Connecting nut. Fully fit the electrode into the connecting nut attached to the electrode holder. 1. Spin a lock nut and a spring washer onto the electrode. Spring washer Spring washer 3. Tighten the electrode with the two clamp screws. 4. Secure the connecting nut by tightening the lock nut and spring washer. 4. Secure the connecting nut by tightening the lock nut and spring washer. Lock nut Electrode. Fully fit the electrode into the connecting nut attached to the electrode holder. 1. Spin a lock nut and a spring washer onto the electrode. Application When using electrodes in sea water or sewage, provide a sufficient interval (normally 1 m) between the electrodes. If the sufficient interval cannot be provided, employ a low-sensitivity type Floatless Level Controller. When taping one of the electrodes to prevent it from contacting the other electrodes in water, do not tape the electrode entirely but leave at least 100 mm of its end uncovered. When the required length of the electrode is more than 1 m, use a separator at each joint of two electrodes so as to prevent the electrodes from contacting one another. (NOTE: Avoid use of the separators in dust-containing liquids.) Usually, electrodes are used in a set of three: long, medium, and short. Connect the short electrode to, the medium electrode to E, and the long electrode to E3. Make E3 at least 50 mm longer than E. Electrodes are in actual contact with the liquid. Standard electrodes are made of stainless steel and usable in purified water, sea water, sewage, acid (except acetic acid, sulfuric acid, etc.) and alkaline liquids, although they may corrode depending upon the temperature and working conditions. Note that the Conductive Level Controller is capable of controlling liquids with specific resistances of up to 30 kω-cm when the controller employs a type PS-3S electrode holder with the electrode(s) submerged to a depth of 30 mm max. Kind of water Specific resistance Applicable type City water 5 to 10 kω-cm General-purpose type Well water to 5 kω-cm General-purpose type Industrial water 5 to 15 kω-cm General-purpose type Rainwater 15 to 5 kω-cm General-purpose type Sea water 0.03 kω-cm Low-sensitivity type Sewage 0.5 to kω-cm Low-sensitivity type Distilled water 100 kω-cm or less High-sensitivity type Over 100 kω-cm Consult OMRON E E3 50 mm min. 1 m 1 m 5

6 Safety Precautions!WARNING Do not touch the terminals while power is being supplied. Doing so may possibly result in electric shock. Make sure that the terminal cover is installed before using the product.!caution Do not attempt to disassemble, repair, or modify the product. Doing so may occasionally result in minor or moderate injury due to electric shock. Check the application and power supply. Power supply (AC 0 V, AC 30 V) consists of other specifications. If the power voltage is not AC 00 V or AC 100 V, follow the instructions described on the device. Firmly ground the earth terminal No.4. Make sure that electrode probes in the liquid do not come in contact one another as it may cause malfunction. Use separator when connecting. Tighten nuts for electrode probe(s) firmly. Prevent flotage from attaching to electrode. This device is not available when the resistance is too high and is not conductive such as oil. Precautions for Safe Use 1. Precautions for the environment Use and preserve within the proper temperature and humidity described in the specifications. Temperature of surroundings for preservation (including during transportation) and use: 10 to 55 C, humidity: 45 to 85%. Do not install, among others, near heat devices such as coils or other devices having coils, etc. Avoid preserving (including during transportation) and using in a humid place, in a corrosive gas environment, outdoors and in a place which receives direct sunlight. Preserve and use without exposing to danger of explosion, flammable dust, gas and vapor, excessive dust, and saline spray or droplets. Avoid preserving (including during transportation) and using in a place which is vulnerable to flooding or oil spillage. Avoid preserving (including during transportation) and using in a place where vibrations and impacts are strong. Similarly, avoid using next to a high-capacity contactor which may impacts at operation. Doing so causes malfunctions such as chattering, etc. Do not install the product near devices generating strong high-frequency waves or surges. When using a noise filter, check the voltage and current and install it as close to the product as possible.. Cautions for Use Read the instruction manual and catalog before operating and maintaining the product. Fit socket(s) and DIN rail(s) so that the screws are tight. If the screws are not tight, DIN rail(s), socket(s), the product and cable(s) may lead to come off. Be sure to fit socket(s) to DIN rail(s) without fail. Use metal strengthener(s) to maintain a firm connection between the product and socket(s). Read the instructions manual and catalog before the operation and maintenance of the product. When fitting crimping terminal(s) to terminal screw(s), use a tightening torque of between 0.45 and 0.6 N m Use power supply of appropriate specifications to provide control source(s), inputs, etc., and to wire cables. [Recommended cable to wire between the model 61F and electrode(s) when using three-core cabtire cable(s) of completely insulated 600 V 0.75 mm VCT: 50 m max.] Do not put power line(s), high-voltage cable(s) and wire(s) of electrode circuit(s) in the same duct nor wire closely. Doing so causes malfunctions by getting vulnerable to induction noise. Shorten the distance for wiring between the model 61F and electrode holders as much as possible. Long distance for wiring may causes malfunctions because stray capacitance may influence operation, or abnormal surges or noise may run through electrode circuit(s). Be sure to ground common electrode terminal(s). Doing so can reduce some effects of noise. Use the product within the noted supply voltage and rated load. Before using, recheck the application, wiring, power supply, etc. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by To convert grams into ounces, multiply by In the interest of product improvement, specifications are subject to change without notice. 6

7 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 01 All Right Reserved.

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm)

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm) CSM_PS-_S(R)_-31_DS_E_7_1 Separate s for Water Supply and Drainage Control in Buildings. Small, Lightweight s for Use as Built-in Components. The PS-@S(R) are separate s that allow the s to be withdrawn

More information

Ordering Information. Conductive Level Controller 61F-GP-N2. Accessories (Order Separately) Selection Guide for Electrode Holders and Separators

Ordering Information. Conductive Level Controller 61F-GP-N2. Accessories (Order Separately) Selection Guide for Electrode Holders and Separators Conductive Level Controller Cat. No. N43I-E-01 Automatic Water Supply and Drainage Control Ideal for level control of any conductive liquid. Compact plug-in controller for single- or two-point control

More information

Key-type Selector Switches

Key-type Selector Switches New Product Key-type Selector Switches ANK Keyed -mm Selector Switches Universal Design. Emphasis on Color Coding, Workability, and Safety. Easy to Use You can connect up to three Blocks in one stage for

More information

Original instructions JSNY7 Magnetic switch

Original instructions JSNY7 Magnetic switch Original instructions JSNY7 Magnetic switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.jokabsafety.com Read and understand this document Please read and understand this

More information

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches Switch-Tek Sump Float Level Switches LV41 & LV42 Series Manual LV41 Series Shown LV42 Series Shown Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA 90720 p 562.598.3015 f 562.431.8507 w flowline.com

More information

Read and understand this manual for safely usage.

Read and understand this manual for safely usage. Read and understand this manual for safely usage. This manual describes the product of standard specification. Read the other manual for the product of explosion-proof specification. This manual describes

More information

Industrial flue gas probes. Instruction manual

Industrial flue gas probes. Instruction manual Industrial flue gas probes Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 4 2.1. About this document... 4 2.2. Ensure safety... 4 2.3. Protecting the environment...

More information

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing Switch Mode Power Supply S8VM (15/30/50/100/150/300/600/1,500-W Models) Power Supply Featuring OMRON s Unique, New Function with Compact Body Contributing to Machine Downsizing New undervoltage alarm function

More information

Cables for I/O Relay Terminals

Cables for I/O Relay Terminals s for I/O Relay s XWZ-R Connect I/O Relay s to I/O Units for Programmable Controllers with one touch. for G70V and G7TC I/O Relay s and G70D, G70A, and G70R Relay s. s with loose wires available with or

More information

Agilent 16047D Test Fixture

Agilent 16047D Test Fixture Agilent 16047D Test Fixture Operation and Service Manual Third Edition Agilent Technologies Japan, Ltd. Agilent PN 16047-90300 May 2000 Printed in Japan Notices The information contained in this document

More information

Drag Chain Conveyor Installation and Operation Manual

Drag Chain Conveyor Installation and Operation Manual Drag Chain Conveyor Installation and Operation Manual Material Handling Equipment Sales, Incorporated 310 S. Section Line Rd Delaware, OH 43015 Phone: (989) 430-4005 Fax: (740) 363-9004 WARRANTY MATERIAL

More information

Agilent 16034E Test Fixture

Agilent 16034E Test Fixture Agilent 16034E Test Fixture Operation and Service Manual Third Edition Agilent PN 16034-90041 December 1999 Printed in: Japan Notices The information contained in this document is subject to change without

More information

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Document No. 1800-56 Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:

More information

HRO-50 Water Purifier

HRO-50 Water Purifier HRO-50 Water Purifier Product Installation & Operation Manual Honeywell Environmental & Combustion Controls (Tianjin) Co., Ltd. Content Important Notes P2 Product Functions P3-P5 Installation Instructions

More information

Phase-sequence Phase-loss Relay

Phase-sequence Phase-loss Relay Phase-sequence Phase-loss Relay K8AK-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Greater resistance to inverter noise. Distinguishes between correct phases, phase sequence,

More information

YINGLI SOLAR TWINMAX MODULES Installation and User Manual

YINGLI SOLAR TWINMAX MODULES Installation and User Manual YINGLI SOLAR TWINMAX MODULES Installation and User Manual Revision Date Aug 3rd, 2016 Applicable for IEC certified products This manual applies to photovoltaic TwinMAX modules ( TwinMAX modules, also commonly

More information

2-finger angular gripper SGB 32-50

2-finger angular gripper SGB 32-50 www.comoso.com Translation of the original manual 2-finger angular gripper SGB 32-50 Assembly and Operating Manual Superior Clamping and Gripping Imprint www.comoso.com Imprint Copyright: This manual remains

More information

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved. For more information, visit www.247technology.com/on-line-ups/c60-standby-ups C60 Standby UPS 800VA Models User & Installation Manual 2015. All rights reserved. (Rev 6/23/15) Table of Contents Package

More information

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS Rev. 1.5 1.10.13 Toll free (800) 288-6000 or www.hubbell-wiring.com P a g e 0 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING- When using

More information

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO Capacitive level meters CLM 36 Capacitive level meters Riels CLM are designed for continuous level measurement of liquids, powders and bulk-solid

More information

Conergy SolarFamulus II

Conergy SolarFamulus II Conergy SolarFamulus II Installation manual www.conergy.com Table of Contents Table of Contents SolarFamulus II for universal use on flat roofs 1 Introduction 1 1.1 Short description 1 1.2 Intended use

More information

Protective Capony RTC-16

Protective Capony RTC-16 Protective Capony RTC-16 ASSEMBLY AND OPERATION MANUAL Protective Canopy RTC-16 Assembly and Operation Manual CONTENT: 1 APPLICATION...3 2 OPERATION CONDITIONS...3 3 TECHNICAL SPECIFICATIONS...3 4 DELIVERY

More information

LAHAINA. Lahaina Showerspa Model #1030 Installation Instructions

LAHAINA. Lahaina Showerspa Model #1030 Installation Instructions LAHAINA Lahaina Showerspa Model #1030 Installation Instructions Lahaina ShowerSpa Model #1030 Please Read The Following Instructions COMPLETELY Before Beginning! Our goal is to ensure your installation

More information

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com MODEL : PHM-12 ARC WELD GUN PART NO. : PHM-12 (PHM-12-RS) SERIAL NO. : PLEASE READ THIS OPERATION AND MAINTENANCE MANUAL CAREFULLY BEFORE USING YOUR NEW CUTLASS STUD WELDER. COPYRIGHT CFI 2009 email: sales@

More information

INSTALLATION PROCEDURE

INSTALLATION PROCEDURE INSTALLATION PROCEDURE VOLU-probe/1, /3, /4 for Round Ducts INSPECTION & HANDLING. VOLU-probes should be carefully inspected for damage prior to installation. Report damage to your Freight Department,

More information

Sulfur tolerant chip resistors

Sulfur tolerant chip resistors Sulfur tolerant chip resistors TRR series Datasheet Features 1)Special construction prevents sulfur gas penetration, significantly increasing reliability. 2)ROHM resistors have obtained ISO91 / ISO / TS16949

More information

SELECTION GUIDE Appearance Sensing distance Operation Mode Connector Shape example (M8) Outer diameter (Ferrous material only) Wiring Output Output no

SELECTION GUIDE Appearance Sensing distance Operation Mode Connector Shape example (M8) Outer diameter (Ferrous material only) Wiring Output Output no Stainless Steel Sensing Face Proximity Switch Model FL7S The FL7S is a proximity switch having a stainless steel sensing face and housing, and is specially designed for welding applications on the automobile

More information

Guide book AS 300 G. Waste water filtration unit. Im Geer 20, D Isselburg. Description / Type-No.: AS 300 G Type 523

Guide book AS 300 G. Waste water filtration unit. Im Geer 20, D Isselburg. Description / Type-No.: AS 300 G Type 523 Waste water filtration unit Manufacturer: deconta GmbH Im Geer 20, D - 46419 Isselburg Description / Type-No.: Type 523 Table of contents on Page 1 Introduction 3 2 Basic safety advice 4 2.1 Intended use

More information

Installation Instructions/Operation and Maintenance Manual. Models PLG-60 PLG-72. PS DOORS Contact Information. Website psdoors.

Installation Instructions/Operation and Maintenance Manual. Models PLG-60 PLG-72. PS DOORS Contact Information. Website psdoors. Rev. 091416 Pallet Gate Installation Instructions/Operation and Maintenance Manual Models PLG-60 PLG-72 Table of Contents Product Information...2 Installation Instructions...3 Operation...6 Inspection

More information

Three-sided barrier compliant to DIN EN ISO Depending on location, design also as wind protection. Clear height (DH) Three-sided barrier

Three-sided barrier compliant to DIN EN ISO Depending on location, design also as wind protection. Clear height (DH) Three-sided barrier of 5 Page Car SingleVario 06 Stack Parker 06 50 for vehicle up to 5.00 m = 6 long (50 for vehicle up to 5.0 m 7 long) Depending on location, design also as wind protection. Product Data CONFORMITY 06/06/G63

More information

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02 Installation plan Tumble dryer PT 8807 EL (Electrically heated) 38.15 en - US Mat. NR. 09 883 210 / 02 U.S.A. Miele, Inc. National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: Fax: 800-991-9380

More information

2-Finger-Parallel-Gripper RH

2-Finger-Parallel-Gripper RH Translation of the original manual 2-Finger-Parallel-Gripper RH 901-940 Assembly and Operating Manual Superior Clamping and Gripping Imprint Imprint Copyright: This manual remains the copyrighted property

More information

Wash Down Duty Non-Contact Sensor

Wash Down Duty Non-Contact Sensor Wash Down Duty Non-Contact Sensor Instruction Manual Models WDDC1-020/040/060/080/100 WDDC2-020/040/060/080/100 WDDV1-020/040/060/080/100 WDDV2-020/040/060/080/100 Table of Contents 1. General Description.....................................

More information

INSTALLATION PROCEDURE

INSTALLATION PROCEDURE INSTALLATION PROCEDURE VOLU-probe/1SS for Round Ducts WARRANTY Air Monitor Corporation (hereinafter referred to as "Seller") warrants that at the time of shipment, products sold pursuant to this contract

More information

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200 ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200 The GRD 4200 is an electronic earthing equipment for tankers during loading and unloading operations of flammable liquids in places with danger of explosion.

More information

Operating Instructions

Operating Instructions Operating Instructions A-2600 SERIES AWWA SWING CHECK VALVE 500 West Eldorado Street Decatur, Illinois 62522 www.muellercompany.com! WARNING! 1. Read and follow all pertinent instructions carefully. Proper

More information

Quick Installation Guide. MVC-PTZ-23X Indoor/Outdoor 23 PTZ Speed Dome Camera

Quick Installation Guide. MVC-PTZ-23X Indoor/Outdoor 23 PTZ Speed Dome Camera MVC-PTZ-23X Indoor/Outdoor 23 PTZ Speed Dome Camera Quick Installation Guide 5101 NW 21st Ave, Suite 210 Fort Lauderdale, FL 33309 www.mace.com (877) 585-6223 Table of Contents 1 QUICK INSTALLATION SPEED

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

INSTALLATION MANUAL Accordion Gangplank Model No. FBL-1000

INSTALLATION MANUAL Accordion Gangplank Model No. FBL-1000 INSTALLATION MANUAL Accordion Gangplank Model No. FBL-1000 PLEASE READ THE ENTIRE CONTENTS OF THIS MANUAL PRIOR TO INSTALLATION AND USE OF THE ACCORDION GANGPLANK. BY PROCEEDING, YOU AGREE THAT YOU FULLY

More information

NARROW PITCH (0.4mm) CONNECTORS P4S SERIES

NARROW PITCH (0.4mm) CONNECTORS P4S SERIES FOR BOARD-TO-BOARD AND BOARD-TO-FPC CONNECTION AXT3, 4 NARROW PITCH (0.4mm) CONNECTORS P4S SERIES NEW 2. Strong resistance to adverse environments! Utilizes construction for high contact reliability. 1)

More information

LOAD RAMP 1000 LB. CAPACITY

LOAD RAMP 1000 LB. CAPACITY LOAD RAMP 1000 LB. CAPACITY 55424 ASSEMBLY AND OPERATING INSTRUCTIONS Safely roll Dirt Bikes and more into your Pickup! 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com

More information

FW66 FORESTRY WINCH FW66. Owner s Manual 19/02/2016

FW66 FORESTRY WINCH FW66. Owner s Manual 19/02/2016 FW66 FORESTRY WINCH FW66 19/02/2016 Owner s Manual TABLE OF CONTENTS INTRODUCTION ---------------------------------------------------------------------------------- 2 INTENDED USE -----------------------------------------------------------------------------------

More information

HIGH SEAL ULF Live Loaded Packing System

HIGH SEAL ULF Live Loaded Packing System Instruction Manual HIGH-SEAL Live-Loaded Packing HIGH SEAL ULF Live Loaded Packing System Contents Introduction... 1 Scope of Manual... 1 Description... 2 Spring Selection... 3 Installation... 3 Parts

More information

Installation, Operation & Maintenance Manual

Installation, Operation & Maintenance Manual Original Instructions Installation, Operation & Maintenance Manual Sentry IC Indexing Cabinet Automatic Sampling Accessories S-AS-IOM-00462-2 11-17 Do not install, maintain, or operate this equipment without

More information

Applications R41 3 I M1 M

Applications R41 3 I M1 M R41, Class Y2, 300 VAC, 110 C (Automotive Grade) Overview The R41 is constructed of metallized polypropylene film encapsulated with self-extinguishing resin in a box of material meeting the requirements

More information

Thermocouple for Flue Gas Temperature Measurements,

Thermocouple for Flue Gas Temperature Measurements, Electrical Temperature Measurement Thermocouples for Flue Gas Temperature Measurements Model TC81 with Thermowell Model TW81 WIKA Data Sheet TE 65.81 Applications Blast furnaces, air heaters Red-heat and

More information

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL Before installation these instructions must be fully read and understood 2010B 3500B 2020B The VAREC Vapor Control Inc. 2010B/2020B/3500B Series pressure and/or vacuum relief valves have not been tested

More information

MICRO-INVERTER PIGRID W MICRO GRID TIED INVERTER 208, 220, 230, 240VAC

MICRO-INVERTER PIGRID W MICRO GRID TIED INVERTER 208, 220, 230, 240VAC MICRO-INVERTER PIGRID250 250W MICRO GRID TIED INVERTER 208, 220, 230, 240V TECHNICAL MANUAL CONTENTS INTRODUCTION ------------------------------------------------------------------------------ 3 SAFETY

More information

Reference Only. Spec. No. JENF243E-0002Q-01 P1 / 8

Reference Only. Spec. No. JENF243E-0002Q-01 P1 / 8 Spec. No. JENF243E-0002Q-01 P1 / 8 Chip EMIFIL LC Combined Type for Large Current NFE31PT 1E9 Reference Specification 1. Scope This reference specification applies to Chip EMIFIL LC Combined Type for Large

More information

Vehicle Restraint Installation Manual

Vehicle Restraint Installation Manual Vehicle Restraint Installation Manual VBR-300 Dok-Lok Hydraulic Vehicle Restraint VBR-300M Dok-Lok Manual Vehicle Restraint VBR-300ALP Dok-Lok Manual Vehicle Restraint With Automatic Light Package MADE

More information

General Guidelines. Tools Required. Instructions for Part # SC500-AF. Safety

General Guidelines. Tools Required. Instructions for Part # SC500-AF. Safety Instructions for Part # SC500-AF General Guidelines It is the user s responsibility to read and follow all instructions. Keep these instructions with the product at all times and review before each use.

More information

Molokai ShowerSpa Model #1006

Molokai ShowerSpa Model #1006 Molokai ShowerSpa Model #1006 Please Read The Following Instructions COMPLETELY Before Beginning! Our goal is to ensure your installation goes smoothly and safely. Please read these instructions carefully

More information

CM-v-3 module. GSM/GPRS/EDGE communication module for MT880 meters. Technical description

CM-v-3 module. GSM/GPRS/EDGE communication module for MT880 meters. Technical description GSM/GPRS/EDGE communication module for MT880 meters Document code: EAD 028.890.101 Version: V1.01 Language: English Date: 06.03.2015 COPYRIGHT 2011 ISKRAEMECO d.d., Merjenje in upravljanje energije. All

More information

RN142S PIN Diodes Outline V R 60 V SOD-523 EMD2 SC-79

RN142S PIN Diodes Outline V R 60 V SOD-523 EMD2 SC-79 RN142S PIN Diodes Outline V R 60 V SOD-523 EMD2 SC-79 Data sheet I F 100 ma C t 0.45 pf rf 3.0 Ω Feature High reliability Small mold type Low rf Low capacitance Inner Circuit Application Packaging Specification

More information

INSTALLATION PROCEDURE

INSTALLATION PROCEDURE INSTALLATION PROCEDURE ELECTRA-flo/FI INSPECTION & HANDLING. The ELECTRA-flo/FI should be carefully inspected for damage prior to installation. Report damage to your Freight Department, or contact delivery

More information

SECTION INFLUENT EQUALIZATION TANK PUMPS

SECTION INFLUENT EQUALIZATION TANK PUMPS PART 1 GENERAL 1.01 SCOPE OF WORK A. The Contractor shall furnish and install all materials, labor and equipment to put into service the Influent Equalization Pumps in accordance with the Contract Drawings

More information

Cables for I/O Relay Terminals

Cables for I/O Relay Terminals s for I/O Relay s XWZ-R Connect I/O Relay s to I/O Units for Programmable Controllers with one touch. s with s for G70V and G7TC I/O Relay s, G70D and G70R Relay s, and G70A and P7TF-IS/OS I/O Sockets.

More information

Universal Tilting TV Mount 32" to 60" Installation Instructions

Universal Tilting TV Mount 32 to 60 Installation Instructions Universal Tilting TV Mount 32" to 60" Installation Instructions Tiltable LCD / TFT TV Wall Mount Material: 2.0mm Cold Rolled Steel Plate TV size: 32" - 60" Tilt angle: 0-15 degrees Max load capacity: 165

More information

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System.  January 2012 Version MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SCP Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description

More information

2016 V1 SERAPHIM ECLIPSE PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG

2016 V1 SERAPHIM ECLIPSE PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG 016 V1 SERAPHIM ECLIPSE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG ROAD NO. 1-. TELEPHONE: +86-519-8877608 FAX: +86-519-88786181 MAILBOX: info@seraphim-energy.com

More information

DISSTON WELDING PRODUCTS TIG/MMA-160/180/200/250D. Welding Machines

DISSTON WELDING PRODUCTS TIG/MMA-160/180/200/250D. Welding Machines DISSTON WELDING PRODUCTS TIG/MMA-160/180/200/250D Welding Machines FOR SAFE OPERATION: Keep the work area clean. Cluttered work areas invite injuries (indoor and outdoor). Consider the work environment.

More information

2.6± ±0.1. Taping specifications (Unit : mm) 4.0± ±0.05 φ1.55± ± ±0.1 φ1.0± Duty 0.5

2.6± ±0.1. Taping specifications (Unit : mm) 4.0± ±0.05 φ1.55± ± ±0.1 φ1.0± Duty 0.5 Rectifying Diode RR264M-400 Datasheet Series Dimensions (Unit : mm) Land size figure (Unit : mm) General Rectifying Application General rectification Features ) Small power mold type (PMDU) 2) High reliability

More information

BakeMax Dough Mini Moulder BMMDM02

BakeMax Dough Mini Moulder BMMDM02 BakeMax Dough Mini Moulder BMMDM02 2 Instruction Manual 1. Preface ------------------------------------------- P2 2. Machine Introduction -------------------------------- P2 3. Machine Specification and

More information

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

Model # 800SM-PS3. 8/3/2016 Page 1 of 8 Model # 800SM-PS3 8/3/2016 Page 1 of 8 /3/2016 Page 2 of 8 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

DRYWALL DOLLY 900 LB. CAPACITY

DRYWALL DOLLY 900 LB. CAPACITY DRYWALL DOLLY 900 LB. CAPACITY 94883 ASSEMBLY & OPERATING INSTRUCTIONS Due to continuing improvement, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo,

More information

Tourmaster 3-Step Riser

Tourmaster 3-Step Riser Assembly Manual Tourmaster 3-Step Riser Note: Shade variations may be present from step to step due to the nap of the carpet. contents Safety Precautions.................................. Warranty..........................................

More information

VI PARTS LIST. , ELECTRIC FRYER PARTS LIST ITEM DESCRIPTION MODELS PART # 10x x24

VI PARTS LIST. , ELECTRIC FRYER PARTS LIST ITEM DESCRIPTION MODELS PART # 10x x24 VI PARTS LIST ORDERING PARTS Parts may be ordered by part number by calling Keating at 1-800-KEATING or your service company. You may also order online at Keating s part store, www.keatingofchicago.com.

More information

4 rotary milling table

4 rotary milling table 4 rotary milling table Model 97208 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from

More information

AHP WELDS USER MANUAL

AHP WELDS USER MANUAL AHP WELDS USER MANUAL Alpha-TIG200X (version III) Contents 1. Safety... 2 2. About your AlphaTig 200X... 3 3. Parameters... 4 4. Panel Index... 5 5. Setup Instructions... 6 6. Operating Instructions...

More information

YOUR SPLASH PAD RESOURCE

YOUR SPLASH PAD RESOURCE 1 Index Permits & Inspections Material List Warnings Splash Pad Types Pre-Site Grading Plumbing Schematic Pressure Testing Concrete Preparation and Pour Housing/Nozzle Installation Above Ground Water Feature

More information

Thermocouples. Operating and Maintenance Manual English. Thermocouples

Thermocouples. Operating and Maintenance Manual English. Thermocouples Thermocouples Operating and Maintenance Manual English Seite 1 / 8 Operating and Maintenance Manual Thermocouples Table of Contents 1 General Information 3 2 Functionality 4 2.1 Thermo Lines and Compensating

More information

G M R H T B F A

G M R H T B F A High power low ohmic chip shunt resistors GMR series Features 1)High power (3W to 5W ) 2)High heat dissipation 3)Excellent TCR characterristics 4)Low ohmic (5mΩ to 220mΩ) Products list Part No. Size (mm)

More information

DJ Switch 10F V2 ORDERCODE 50365

DJ Switch 10F V2 ORDERCODE 50365 DJ Switch 10F V2 ORDERCODE 5035 Congratulations! You have bought a great, innovative product from Showtec. The Showtec DJ Switch brings excitement to any venue. Whether you want simple plug-&-play action

More information

EMD59. Datasheet. Complex Digital Transistors (Bias Resistor Built-in Transistors)

EMD59. Datasheet. Complex Digital Transistors (Bias Resistor Built-in Transistors) EMD59 Complex Digital Transistors (Bias Resistor Built-in Transistors) Datasheet loutline Parameter Value SOT-563 V CC 50V SC-107C I C(MAX.) 100mA R 1 10kΩ R 2 47kΩ EMT6

More information

Installation Instructions

Installation Instructions Installation Instructions AquaSnap 010-055 Chilled Water Storage Tank 50/60 Hz Part No: -900---001; -900---009; -900---010 CONTENTS INTRODUCTION.................................. 1 SAFETY CONSIDERATIONS......................

More information

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols. VIGO INDUSTRIES INSTALLATION GUIDE FOR STANDING SHOWER CABIN (MODEL VG06062) SAFETY PRECAUTIONS This Installation Guide uses the following symbols to indicate important information. Always observe the

More information

High power chip resistors < Wide terminal type > LTR series

High power chip resistors < Wide terminal type > LTR series High power chip resistors < Wide terminal type > LTR series Features 1)High joint reliability with long side terminations. 2)Highest power ratings in their class. 3)Guaranteed anti-surge characteristic

More information

Features SCL-DPDT SCL-DPDT-C1 SCL-DPDT-V SCL-DPDT-S SCL-D-DPDT SCL-D-DPDT-C1 SCL-D-DPDT-V SCL-D-DPDT-S

Features SCL-DPDT SCL-DPDT-C1 SCL-DPDT-V SCL-DPDT-S SCL-D-DPDT SCL-D-DPDT-C1 SCL-D-DPDT-V SCL-D-DPDT-S Type List Terminal style Quick terminal Contact form Designation Features A general purpose Power Relay. Contact rating up to 12A 250VAC (). Epoxy sealed type and flux free. Quick connect terminal or PCB

More information

RESD1CANFH Transient Voltage Suppressor (AEC-Q101 qualified) Data sheet

RESD1CANFH Transient Voltage Suppressor (AEC-Q101 qualified) Data sheet RESD1CANFH Transient Voltage Suppressor (AEC-Q101 qualified) Data sheet V RWM 24 V P PP 350 W V CL 44 V Outline Features Small mold type High reliability Inner Circuit Application Packaging Specification

More information

Precision Thick Film Chip Resistors ERJ G: 0201 ERJ R: 0402, 0603, 0805 ERJ E : 0603, 0805, 1206, 1210, 1812, 2010, 2512

Precision Thick Film Chip Resistors ERJ G: 0201 ERJ R: 0402, 0603, 0805 ERJ E : 0603, 0805, 1206, 1210, 1812, 2010, 2512 Precision Thick Film Chip esistors J G: J : 4, 6, 5 J : 6, 5, 6,,,, 5 Type: J G J,, 6 J, 6,, 4,, T n Features l Small size and lightweight For PCB size reduction and lightweight products l High reliability

More information

Loading Arm Installation, Maintenance & Safety Manual

Loading Arm Installation, Maintenance & Safety Manual Loading Arm Installation, Maintenance & Safety Manual Version Loading Arm Hot Line: 1-800-547-9393 Dear OPW Customer: Thank you for selecting OPW Engineered Systems, Inc. ("OPW"), and giving us the opportunity

More information

2SD1980 V CEO 100V I C 2A R 1 R kΩ 300Ω. Datasheet. Power Transistor (100V, 2A)

2SD1980 V CEO 100V I C 2A R 1 R kΩ 300Ω. Datasheet. Power Transistor (100V, 2A) 2SD1980 Power Transistor (100V, 2A) Datasheet loutline Parameter Value V CEO 100V TO-252 SC-63 I C 2A R 1 R 2 3.5kΩ 300Ω CPT lfeatures 1)Darlington connection for high DC current again. 2)Built-in resistor

More information

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES The manufacturer guarantees only English text. Available on our web site:

More information

Applications R49 A N B1 M

Applications R49 A N B1 M R49, Class X1, 330 VAC, 110 C Overview The R49 is constructed of metallized polypropylene film encapsulated with self-extinguishing resin in a box of material meeting the requirements of UL 94 V 0. Applications

More information

DTC143XCA. Datasheet. NPN 100mA 50V Digital Transistor (Bias Resistor Built-in Transistor)

DTC143XCA. Datasheet. NPN 100mA 50V Digital Transistor (Bias Resistor Built-in Transistor) DTC143XCA NPN 100mA 50V Digital Transistor (Bias Resistor Built-in Transistor) Datasheet loutline Parameter Value SOT-23 V CC 50V I C(MAX.) 100mA R 1 4.7kΩ R 2 10kΩ (SST3) lfeatures 1) Built-In Biasing

More information

ROOF MOUNT KIT OWNERS MANUAL

ROOF MOUNT KIT OWNERS MANUAL ROOF MOUNT KIT OWNERS MANUAL Made in the USA by: Primus Wind Power, Inc. 938 Quail St. Lakewood, CO 80215 Phone: (303) 242-5820 www.primuswindpower.com AIR is a trademark of Primus Wind Power, Inc. ROOF

More information

Schottky Barrier Diode RBQ30TB45BHZ

Schottky Barrier Diode RBQ30TB45BHZ Schottky Barrier Diode RBQ3TB45BHZ AEC-Q Qualified Application Dimensions (Unit : mm) Structure Switching power supply Features ) Power Mold Type () (3) Cathode Anode 2) High reliability 3) Low I R Construction

More information

READ AND SAVE THESE INSTRUCTIONS SEISMIC. Cer tification Option. Installation Manual

READ AND SAVE THESE INSTRUCTIONS SEISMIC. Cer tification Option. Installation Manual READ AND SAVE THESE INSTRUCTIONS SEISMIC Cer tification Option Installation Manual Warnings and cautions Indicates a hazardous situation that could result in death or serious injury if instructions are

More information

Reference Only. Spec. No. JENF243E-0003Q-01 P 1 / 8. Chip EMIFIL LC Combined Type for Large Current NFE61PT 1H9 Reference Specification

Reference Only. Spec. No. JENF243E-0003Q-01 P 1 / 8. Chip EMIFIL LC Combined Type for Large Current NFE61PT 1H9 Reference Specification Spec. No. JENF243E-0003Q-01 P 1 / 8 Chip EMIFIL LC Combined Type for Large Current NFE61PT 1H9 Reference Specification 1. Scope This reference specification applies to Chip EMIFIL LC Combined Type for

More information

RSD250 Unwind Dancer Package WEB CONTROL PRODUCTS FORM NO. L B User Manual. MTY (81)

RSD250 Unwind Dancer Package WEB CONTROL PRODUCTS FORM NO. L B User Manual. MTY (81) WEB CONTROL PRODUCTS User Manual RSD250 Unwind Dancer Package FORM NO. L-279-B-003 FORM NO. L-279-B-003 In accordance with Nexen s established policy of constant product improvement, the specifications

More information

Reference Only. Spec. No. JENF243D-0006K-01 P 1/ 8

Reference Only. Spec. No. JENF243D-0006K-01 P 1/ 8 Spec. No. JENF243D-0006K-01 P 1/ 8 Chip EMIFIL LC Combined Monolithic NFL21SP X1C Reference Specification 1. Scope This reference specification applies to Chip EMIFIL LC Combined Monolithic Type NFL21S

More information

Applications R46 K I P0 M

Applications R46 K I P0 M Overview The R46 Series is constructed of metallized polypropylene film encapsulated with self-extinguishing resin in a box of material meeting the requirements of UL 94 V 0. Applications For worldwide

More information

HotSwap MBP Maintenance Bypass

HotSwap MBP Maintenance Bypass ENGLISH HotSwap MBP Maintenance Bypass MBP6K208 MBPK208 Installation and user manual Copyright 202 EATON All rights reserved. Service and suort: Call your local service representative SAFETY INSTRUCTIONS

More information

Reference Only. 2.Part Numbering (ex) NF Z 5B BW 2R9 L N 1 0 L

Reference Only. 2.Part Numbering (ex) NF Z 5B BW 2R9 L N 1 0 L SpecNo.JENF243J-0011A-01 P1/10 CHIP NOISE FILTER NFZ5BBW LN10 REFERENCE SPECIFICATION 1.Scope This reference specification applies to NFZ5BBW_LN10L Series, Chip Noise Filter. 2.Part Numbering (ex) NF Z

More information

No.JEMCP B a)equivalent Circuit 5.Rated value MURATA PART NO. NFM2CC0UH3D NFM2CC02RH3D (3) Nominal Capacitance Capacitance Tolerance

No.JEMCP B a)equivalent Circuit 5.Rated value MURATA PART NO. NFM2CC0UH3D NFM2CC02RH3D (3) Nominal Capacitance Capacitance Tolerance No.JEMCP0-00863B CHIP EMIFIL CHIP 3-TERMINAL CAPACITOR FOR GENERAL NFM2CC Series Reference Sheet.Scope 2.Reference PART No. List 2 3 4 5 6 7 8 3.MURATA Part NO. System (Ex.) This product specification

More information

VISE MOUNTED. Model 97359

VISE MOUNTED. Model 97359 VISE MOUNTED Small English wheel Model 97359 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly

More information

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED Chapter 17 Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.1.1 Applicability The regulations in this chapter apply to any private potable water supply system where plumbing fixtures are

More information

24 Portable Saw Mill OWNER S MANUAL

24 Portable Saw Mill OWNER S MANUAL 24 Portable Saw Mill OWNER S MANUAL WARNING: Carefully read and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

Series Sump and Sewage Systems

Series Sump and Sewage Systems Series 000 Sump and Sewage Systems file no: 0. date: may 17, 13 supersedes: 0. date: march 29, 13 Series 000 Sump Series 0 & 2 Armstrong offers a complete range of high performance, easily maintained Column

More information

FTW 175 Wireless Monitoring System Reference Manual Part Number

FTW 175 Wireless Monitoring System Reference Manual Part Number FTW 175 Wireless Monitoring System Reference Manual Part Number 7911751 SERIAL NUMBER Flash Technology, 332 Nichol Mill Lane, Franklin, TN 37067 www.spx.com/en/flash-technology (615) 261-2000 Front Matter

More information