ETAP PowerStation 4.0

Size: px
Start display at page:

Download "ETAP PowerStation 4.0"

Transcription

1 ETAP PowerStation 4.0 User Guide Copyright 2001 Operation Technology, Inc. All Rights Reserved This manual has copyrights by Operation Technology, Inc. All rights reserved. Under the copyright laws, this manual may not be copied, in whole or in part, without the written consent of Operation Technology, Inc. The Licensee may copy portions of this documentation only for the exclusive use of Licensee. Any reproduction shall include the copyright notice. This exception does not allow copies to be made for other persons or entities, whether or not sold. Under this law, copying includes translating into another language. Certain names and/or logos used in this document may constitute trademarks, service marks, or trade names of Operation Technology, Inc. or other entities. Access, Excel, ODBC, SQL Server, Windows NT, Windows 2000, Windows Me, Windows 98, Windows XP, and Microsoft Word are registered trademarks of Microsoft Corporation. AutoCad is a registered trademark of Autodesk. Oracle is a registered trademark of Oracle Corporation. PowerPlot is a registered trademark of Jackson & Associates. Crystal Reports is a registered trademark of Seagate Software. MATLAB and Simulink are registered trademarks of MathWorks Screen shot(s) reprinted by permission from Microsoft Corporation. Operation Technology, Inc. believes that the information contained herein is accurate as of its publication date, and such information is subject to change without notice. This information is provided as is without warranty of any kind, either expressed or implied, including but not limited to the implied warranties of merchantability, fitness for a particular purpose, or noninfringement. Operation Technology, Inc. assumes no responsibility for errors or omissions in this publication or any other documents referenced in this publication. Operation Technology, Inc. Southern California (949) Sales (949) Fax (949) User Support

2 Chapter 17 Transient Stability Analysis The PowerStation Transient Stability Analysis program is designed to investigate the stability limits of a power system before, during, and after system changes or disturbances. The program models dynamic characteristics of a power system, implements the user-defined events and actions, solves the system network equation and machine differential equations interactively to find out system and machine responses in time domain. From these responses, users can determine the system transient behavior, make stability assessment, find protective device settings, and apply the necessary remedy or enhancement to improve the system stability. This chapter describes different tools to assist you in running transient stability studies. An overview on the basics of transient stability study is also provided. This chapter is organized into 8 sections. The Transient Stability Toolbar section explains how you can launch a transient stability calculation, open and view an output report, select display options, and view plots. The Study Case Editor section explains how to create a new study case, to define parameters for a study case, to create a sequence of switching events and disturbances, to globally define machine dynamical modeling method, to select plot/tabulation devices, etc. The Display Options section explains what options are available for displaying some key system parameters and the output results on the oneline diagram, and how to set them. The Calculation Methods section provides some theoretical backgrounds and quick reference for the fundamentals on transient stability study, which are very helpful for users who do not have extensive experience on running transient stability studies. The Required Data section is a very good reference for you to check if you have prepared all necessary data for transient stability calculations. These data range from the system side, such as bus and branch information, to the machine side, such as machine model and parameters, exciter model and parameters, and governor model and parameters. The Output Reports section explains and demonstrates the format and organization of the transient stability text reports. The One-Line Diagram Displayed Results section explains the available one-line displaying results and provides one example. The Plots section explains what plots for transient stability are available and how to select and view them. Operation Technology, Inc ETAP PowerStation 4.0

3 Toolbar 17.1 Transient Stability Toolbar The Transient Stability Toolbar will appear on the screen when you are in the Transient Stability Study mode. Run Transient Stability Display Options Report Manager Transient Stability Plots Halt Current Calculation Get On-Line Data Get Archived Data Run Transient Stability Select a study case from the Study Case Toolbar. Then click on the Run Transient Stability button to perform a transient stability study. A dialog box will appear to ask you to specify the output report name if the output file name is set to Prompt. When the calculation completes, the transient stability study results will appear on the one-line diagram and are stored in the output report, as well as in the plot file. Display Options Click the Display Options button to customize the one-line diagram annotation options under the transient stability study mode. Also to edit the one-line diagram display for transient stability calculation results. See Display Options for more information. Report Manager Click on Report Manager button to select a format and view transient stability output report. Transient stability analysis reports are current provided in ASCII formats only, which can be accessed from the Report Manager. Operation Technology, Inc ETAP PowerStation 4.0

4 Toolbar You can also select output files from the Output Report list box. This list contains all the output files in the current project folder with the same file extension specified. To change output file extensions, you can click on the List Output Reports button next to the Output Report list box, which will allow you to select a different output file extension. The output reports for transient stability studies have a.tsr extension. PowerStation text output reports can be viewed by any word processor such as Notepad, WordPad, and Microsoft Word. Currently, by default, the output reports are viewed by Notepad. You can change the default viewer in the ETAPS.INI file to the viewer of your preference. Refer to Chapter 1, Product Description, or Chapter 7, Printing & Plotting for more details. Operation Technology, Inc ETAP PowerStation 4.0

5 Toolbar The output reports are 132 characters wide with 66 lines per page. For the correct formatting and pagination of output reports, you MUST modify the default settings of your word processor application. For Notepad, WordPad, and Microsoft Word applications we have recommend settings that are explained in Chapter 7, Printing & Plotting. Transient Stability Plots Click on the Transient Stability Plots button to select and plot the curves of the last plot file. The plot file name is displayed on the Study Case Toolbar. The transient stability plot files have the following extension:.tsp. For more information see Plots section. Halt Current Calculation The Stop Sign button is normally disabled. When a transient stability calculation has been initiated, this button becomes enabled and shows a red stop sign. Clicking on this button will terminate the current calculation. One-line diagram display will not be available if you terminate the calculation before it completes; but the text output report and plots do store the calculation results up to the time instant when you terminate the calculation. Get On-Line Data If the ETAP key installed on your computer has the on-line feature, you can copy the on-line data from the on-line presentation to the current presentation. Get Archived Data If the ETAP key installed on your computer has the on-line feature, you can copy the archived data to the current presentation. Operation Technology, Inc ETAP PowerStation 4.0

6 Study Case Editor 17.2 Study Case Editor The Transient Stability Study Case Editor contains solution control variables, loading conditions, event and action specifications, machine modeling selections and a variety of options for output reports and plots. PowerStation allows you to create and save an unlimited number of study cases. Transient stability calculations are conducted and reported in accordance to the settings of the study case selected in the Study Case Toolbar. You can easily switch between study cases without the trouble of resetting the study case options each time. This feature is designed to organize your study efforts and save you time. As a part of the multi-dimensional database concept of PowerStation, study cases can be used for any combination of the three major system toolbar components, i.e. for any configuration status, one-line diagram presentation, and Base/Revision Data. When you are in the Transient Stability Analysis mode, you can access the Transient Stability Study Case Editor by clicking on the Study Case button on the Transient Stability Toolbar. You can also access this editor from the Project View by clicking on the Transient Stability subfolder under the Study Cases folder. To create a new study case, go to the Project View, right-click on the Transient Stability Study Case folder, and select Create New. The program will then create a new study case, which is a copy of the default study case, and adds it to the Transient Stability Study Case folder. The Transient Stability Study Case Editor consists of four pages: Info Page, Events Page, Dyn Model Page, and Plot Page. Operation Technology, Inc ETAP PowerStation 4.0

7 Study Case Editor Info Page This page is provided for you to specify some general solution parameters and study case information. Study Case ID Study case ID is shown in this entry field. You can rename a study case by simply deleting the old ID and entering a new ID. Study case ID can be up to 12 alphanumeric characters. Use the Navigator button at the bottom of the editor to go from one study case to another. Initial Load Flow In this section you can specify the solution parameters for initial load flow calculation in transient stability analysis. Max Iteration Enter the maximum number of iterations. If the solution has not converged at the specified number of iterations, the program will stop and inform the user. The recommended and default value is Solution Precision Enter the value for the solution precision that is used to check for convergence. This value determines how precise you want the final solution to be. The default (and recommended) value is Accel. Factor Enter the convergence acceleration factor to be used between iterations. Typical values are between 1.2 and 1.7. The default value is Operation Technology, Inc ETAP PowerStation 4.0

8 Study Case Editor Solution Parameters Simulation Time Step This is the integration time step in seconds in transient stability simulation. You should set this number smaller than the smallest time constant in the system so you can see all the exciter and governor responses. Note that the smaller this number is, the more calculations are required, so the calculation time increases. The recommended value is seconds. If you feel you need higher resolution, decrease this number. However, if the integration time step is too small, accumulated round up errors may increase. Plot Time Step This value determines how often PowerStation should record the results of the simulation for plotting. For instance, if you specify 20 steps, PowerStation will plot points at every 20 simulation time step, i.e., for a simulation time step of 0.001, the plot time step will be.02 seconds. The smaller this number is, the smoother your plots will look, but also remember that the plot files on your hard disk may grow quite large. Keep in mind that PowerStation records plot information at this interval throughout the simulation. For example, if you specified a simulation time step of seconds, plot time step of 10, and a total time of 20 seconds, PowerStation will write 20 / (0.001*10)= 2000 points to disk, which may be a very large plot file, depending on the number of machines and buses being plotted. Apply XFMR Phase-Shift Select this option to include transformer phase-shift specified in the transformer editors in both transient stability initial load flow calculation and time simulation calculation. Otherwise transformer phase-shift will be ignored (i.e., 0 degree phase-shift regardless of the transformer winding connections). Initial Loading In the Initial Loading block of the Transient Stability Study Case Editor, you can specify the system initial operating loads by selecting a loading. The initial loading conditions will establish an initial normal operation condition for the transient stability studies. Loading Category Select one of the ten loading categories for this study case. With the selection of any category, PowerStation uses the percent loading of individual motors and other loads as specified for the selected category. Note that you can assign loading to each one of the ten categories in the Nameplate page, Loading page, or Rating page for most load components. Harmonic Filter loading is calculated from its parameters. Operating Load Check this option to operate P and Q as specified in the relevant component editors. Charger Loading Load Category Select this option to use the P and Q specified in the Loading Category section of the Charger Editor for chargers. Operation Technology, Inc ETAP PowerStation 4.0

9 Study Case Editor Operating Load Select this option to use the P and Q as specified in the Operating Load section of the Charger Editor. If this option is selected, a DC load flow calculation is required to run first in order to estimate the charger load. Load Diversity Factor Apply appropriate load diversity factor(s) for transient stability initial load flow calculation. The choices are: None Select None to use the percent loading of each load as entered for the selected Loading Category, i.e., no diversity factor is considered. Bus Maximum When the Bus Maximum option is selected, the loading of all motors and other loads will be multiplied by the maximum diversity factor of the bus, which they are directly connected to. Using this option, you can define the initial loading for transient stability studies with each bus having a different maximum diversity factor. This study option is helpful when the future loading of the electrical system has to be considered and each bus may have a different maximum diversity factor. Bus Minimum When the Bus Minimum option is selected, the loading of all motors and other loads will be multiplied by the bus minimum diversity factor of the bus that they are directly connected to. Using this option, you can define the initial loading for transient stability studies with each bus having a different minimum diversity factor. This study option may be used to see the effect of transformer taps and capacitors (if any) on the system voltages under a minimum (light) loading condition. Global When this option is selected, PowerStation will ask you to enter global diversity factors for constant kva and constant Z loads, respectively. When you select this option, PowerStation will globally multiply all constant kva and constant Z loads of the selected loading category with the entered values. When using this option, you can define the initial loading for transient stability analysis studies with fixed diversity factors for all loads. Note that a constant kva load diversity factor of 125% implies that the constant kva loads of all buses are increased 25% above their values as specified by the selected loading category. This value can be smaller or greater than 100%. Remarks 2nd Line You can enter up to 120 alphanumeric characters in the Remarks box. Information entered in this location will be printed on the second line of the header information in every page of the output report. These remarks can provide specific information and conditions for each study case. Note that the first line of the header information is global for all study cases and is entered in the Project Information Editor. Operation Technology, Inc ETAP PowerStation 4.0

10 Study Case Editor Events Page This page is provided for you to design and store transient stability study scenarios and events. Events In this list, all events are displayed in their time order to give you a clear picture of the event sequence in this study. The active events are marked by '*' and are listed first, followed by those which are inactive. Event ID The Event ID is a unique name with a maximum length of 12 alphanumeric characters. Time This is the time when the associated event occurs. The unit is in second. Add (Event) A new event can be added by clicking on the Add (Event) button and opening the Event Editor. Active Select this option to make an event active. Clicking on the box again will make the event inactive. Only active events will be included in the study. Operation Technology, Inc ETAP PowerStation 4.0

11 Study Case Editor Edit (Event) Click on the Edit (Event) button to open the Event Editor and edit an existing event. You can also double-click on an event in the Event list to activate the Event Editor. Delete (Event) Delete an existing event from the list. Actions Each event can encapsulate a number of actions (system changes or disturbances). When you select an event by highlighting that event in the Event list, the actions associated with that event will be displayed in the Action list. Each action is composed of the information of the Device Type, the Device ID, and an Action. Note that the event ID is displayed on top of the Action list for your reference. Device Type The type of device that is going to take an action. Device ID The ID of the device that is going to take an action. Action The action to be taken by the specified device and the device type. The following is a table showing device types and their associated actions: Device Type Bus Cable Line Impedance Circuit Breaker SPST Switch Fuse Generator Utility Syn. Motor Ind. Motor MOV None Actions Fault / Clear Fault Fault at ¼ /Fault at ½ / Fault at ¾ / Clear Fault Fault at ¼ /Fault at ½ / Fault at ¾ / Clear Fault Fault at ¼ /Fault at ½ / Fault at ¾ / Clear Fault Open / Close Open / Close Open / Close Ref. Machine / Delete / Droop / Isoch / Start / Loss Excitation Ref. Machine / Delete Delete Accelerate / Delete Start Load Flow (no action, print load flow at the event time) Add (Action) A new action can be added by clicking on the Add (Action) button and opening the Action Editor. Select a device type from the Device Type drop-down list. Select the device ID from the Device ID drop-down list. Select an action from the Action drop-down list. Edit (Action) Click on the Edit (Action) button to edit an existing action. You can also double-click on a listed action to bring up the Action Editor. Operation Technology, Inc ETAP PowerStation 4.0

12 Study Case Editor Delete (Action) Delete an existing action. Total Simulation Time The total simulation time for a transient stability study. The unit is in seconds Dyn Model Page This page is provided to globally specify if you want to dynamically model synchronous and induction motors in the system. Motors are subdivided into medium voltage (above 1.0 kv) and low voltage (less than or equal to 1.0kV) synchronous motor and induction machine groups. A machine will be dynamically modeled if you have specified a dynamic model in its editor and you select to globally model that motor group from this page. Note that all synchronous generators are dynamically modeled. Machine Type Syn. Motors, MV The machine group consisting of all synchronous motors, which are medium voltage (rated above 1.0 kv). Operation Technology, Inc ETAP PowerStation 4.0

13 Study Case Editor Syn. Motors, LV The machine group consisting of all synchronous motors that are low voltage (rated less than or equal to 1.0 kv). Ind. Machines, MV The machine group consisting of all induction machines that are medium voltage (above 1.0 kv). Ind. Machines, LV The machine group consisting of all induction machines that are low voltage (rated less than or equal to 1.0 kv). Dynamic Modeling Do Not Model If selected, the corresponding machine group will not be dynamically modeled in the transient stability study for this study case, regardless of dynamic models specified for individual machines. Model Machines Larger or Equal To If selected, machines that are in the corresponding machine group and rated larger than the size specified in the HP/kW field will be dynamically modeled, and machines in the same group that are rated less than the size specified will not be dynamically modeled. Note that for the machine to be dynamically modeled, it should also have a dynamic model specified for it from its editor. HP/kW Specify the size of machines (in HP or kw) for the selected machine group to be dynamically modeled. Starting Load for Accelerating Motors Specify the base for load torque vs. slip models used for accelerating motors. Based on Motor Electrical Rating Load torque vs. slip curve is defined based on the motor electrical rating, i.e., the load torque vs. slip curve will be scaled to reach 100% at the synchronous speed, corresponding to 100% of the motor electrical rating. Based on Motor Mechanical Load Load torque vs. slip curve is defined based on the motor mechanical load, i.e., the load torque vs. slip curve will not be scaled. Generator Start-Up Specify special frequency dependent models for generator start-up studies here. Frequency Dependent Models for Network, Motors, & Generators The network, motors, and generators will be modeled as frequency dependent. This option has to be checked in order to perform the generator start-up study. Operation Technology, Inc ETAP PowerStation 4.0

14 Study Case Editor Plot Page This page is provided for you to select devices to be plotted for viewing transient stability study results. Device Type Select a device type. Syn. Generators The machine group consisting of all synchronous generators. Syn. Motors, MV The machine group consisting of all dynamically modeled synchronous motors, which are rated above 1.0 kv. Syn. Motors, LV The machine group consisting of all dynamically modeled synchronous motors which are rated equal to or less than 1.0 kv. Ind. Machines, MV The machine group consisting of all dynamically modeled induction machines, which are rated above 1.0 kv. Operation Technology, Inc ETAP PowerStation 4.0

15 Study Case Editor Ind. Machines, LV The machine group consisting of all dynamically modeled induction machines which are rated equal to or less than 1.0 kv. Buses The device group consisting of all buses. MOVs The device group consisting of all MOVs with initially open or closed status. Branches The device group, consisting of all different types of branches, with the exception of tie circuit breakers (protective devices). Plot Options Once a machine or device group is selected, all devices in that group will be displayed in the Plot Options list for you to select. Device ID Device IDs for the selected machine or device group, excluding the non-dynamically modeled machines. Plot/Tabulation (column) You can click on this column to select or deselect the plot/tabulation option for a particular device. Once this option is set, an X will show in this column next to the selected device. By selecting this option, information for the selected device will be tabulated at the end of the transient stability output report and stored in the plot file to be plotted. Plot/Tabulation (check box) This provides another way to set the plot/tabulation option for the highlight device. Operation Technology, Inc ETAP PowerStation 4.0

16 Display Options 17.3 Display Options The Transient Stability Analysis Display Options consist of a Results page and three pages for AC, AC- DC, and DC info annotations. Note that the colors and displayed annotations selected for each study are specific to that study Results Page The Results page allows you to define options for one-line diagram calculation results display. These results can be displayed for each plot time step as selected from the Time Slider. The results include bus voltage and frequency, synchronous machine power angle and frequency, induction motor speed, and power flow to machines. The bus and machine data that are displayed on the one-line diagram are the same data, which are stored in the plot file, i.e., to show a bus voltage and frequency on the one-line diagram, you need to request a plot for that bus. Color Select the color for result annotations to be displayed on the one-line diagram. Show Units Select the check boxes under this heading to show units for the displayed results. Bus Display the calculated voltage and frequency of buses selected for plotting. Voltage Bus voltage in kv or in percent of the bus nominal kv. Frequency Bus frequency in hertz or in percent of system frequency. Operation Technology, Inc ETAP PowerStation 4.0

17 Display Options Syn. Machines Display the calculated power angle and frequency of synchronous generators and motors, which are selected for plotting from the Study Case. Power Angle Machine power (rotor) angle in degrees or radians. Frequency Machine frequency in hertz or in percent of system frequency. Ind. Machines Speed Display speed of induction machines (RPM or % Slip), which are selected for plotting from the Study Case. % Slip = (ω s - ω m ) / ω s Machine Flows Specify how the flows will be displayed in (kw+jkvar or MW+jMvar), or (kva or MVA), or Amp. Transient Stability Study Results Displayed on the One-Line Diagram at Time 1.38 Seconds Operation Technology, Inc ETAP PowerStation 4.0

18 Display Options AC Page This page includes options for displaying info annotations for AC elements. Color Select the color for information annotations to be displayed on the one-line diagram. ID Select the check boxes under this heading to display the ID of the AC elements on the one-line diagram. Rating Select the check boxes under this heading to display the ratings of the AC elements on the one-line diagram. Device Type Gen. (Generator) Power Grid (Utility) Motor Load Panel Transformer Branch, Impedance Branch, Reactor Cable / Line Bus Node CB Fuse Relay PT & CT Rating kw / MW MVAsc HP / kw kva / MVA Connection Type (# of Phases - # of Wires) kva / MVA Base MVA Continuous Amps # of Cables - # of Conductor / Cable - Size ka Bracing Bus Bracing (ka) Rated Interrupting (ka) Interrupting (ka) 50/51 for Overcurrent Relays Transformer Rated Turn Ratio kv Select the check boxes under this heading to display the rated or nominal voltages of the selected elements on the one-line diagram. For cables/lines, the kv check box is replaced by the cable/line conductor type on the one-line diagram. button. Click on this button to display the A Select the check boxes under this heading to display the ampere ratings (continuous or full-load ampere) of the selected elements on the one-line diagram. For cables/lines, the Amp check box is replaced by the cable/line length on the one-line diagram. button. Click on this button to display the Operation Technology, Inc ETAP PowerStation 4.0

19 Display Options Z Select the check boxes under this heading to display the rated impedance of the selected AC elements on the one-line diagram. Device Type Impedance Generator Subtransient reactance Xd Power Grid (Utility) Positive Sequence Impedance in % of 100 MVA (R + j X) Motor % LRC Transformer Positive Sequence Impedance (R + j X per unit length) Branch, Impedance Impedance in ohms or % Branch, Reactor Impedance in ohms Cable / Line Positive Sequence Impedance (R + j X in ohms or per unit length) D-Y Select the check boxes under this heading to display the connection types of the selected elements on the one-line diagram. For transformers, the operating tap setting for primary, secondary, and tertiary windings are also displayed. The operating tap setting consists of the fixed taps plus the tap position of the LTC. Composite Motor Click on this check box to display the AC composite motor IDs on the one-line diagram, then select the color in which the IDs will be displayed. Use Default Options Click on this check box to use PowerStation s default display options AC-DC Page This page includes options for displaying info annotations for AC-DC elements and composite networks. Color Select the color for information annotations to be displayed on the one-line diagram. ID Select the check boxes under this heading to display the IDs of the selected AC-DC elements on the oneline diagram. Rating Select the check boxes under this heading to display the ratings of the selected AC-DC elements on the one-line diagram. Device Type Charger Inverter UPS VFD Rating AC kva & DC kw (or MVA / MW) DC kw & AC kva (or MW / MVA) kva HP / kw Operation Technology, Inc ETAP PowerStation 4.0

20 Display Options kv Click on the check boxes under this heading to display the rated or nominal voltages of the selected elements on the one-line diagram. A Click on the check boxes under this heading to display the ampere ratings of the selected elements on the one-line diagram. Device Type Charger Inverter UPS Amp AC FLA & DC FLA DC FLA & AC FLA Input, output, & DC FLA Composite Network Click on this check box to display the composite network IDs on the one-line diagram, then select the color in which the IDs will be displayed. Use Default Options Click on this check box to use PowerStation s default display options DC Page This page includes options for displaying info annotations for DC elements. Color Select the color for information annotations to be displayed on the one-line diagram. ID Select the check boxes to display the IDs of the selected DC elements on the one-line diagram. Rating Select the check boxes to display the ratings of the selected DC elements on the one-line diagram. Device Type Battery Motor Load Elementary Diagram Converter Cable Rating Ampere Hour HP / kw kw / MW kw / MW kw / MW # of Cables - # of Conductor / Cable - Size kv Select the check boxes under this heading to display the rated or nominal voltages of the selected elements on the one-line diagram. For cables, the kv check box is replaced by the button. Click on this button to display the conductor type on the one-line diagram. Operation Technology, Inc ETAP PowerStation 4.0

21 Display Options A Select the check boxes under this heading to display the ampere ratings of the selected elements on the one-line diagram. For cables, the Amp check box is replaced by the button. Click on this button to display the cable length (one way) on the one-line diagram. Z Select the check boxes under this heading to display the impedance values of the cables and impedance branches on the one-line diagram. Composite Motor Click on this check box to display the DC composite motor IDs on the one-line diagram, then select the color in which the IDs will be displayed. Operation Technology, Inc ETAP PowerStation 4.0

22 Calculation Methods 17.4 Calculation Methods Performing the power system transient stability study is a very comprehensive task. It requires knowledge of machine dynamic models, machine control unit models (such as excitation system and automatic voltage regulators, governor and turbine/engine systems, and power system stabilizers), numerical computations, and power system electromechanical equilibrium phenomena. The full discussion on this topic is far beyond the scope of this manual. In this section, we will brief you with some fundamentals and underlying principles on the power system transient stability study, with the focus on applications with PowerStation. Purpose for Performing Transient Stability Study Dynamic performance of a power system is significant in the design and operation of the system. The transient stability study determines the machine power angles and speed deviations, system electrical frequency, real and reactive power flows of the machines, power flows of lines and transformers, as well as the voltage levels of the buses in the system. These system conditions provide indications for system stability assessments. The results are displayed on the one-line diagram, and also can be printed or plotted. For transient stability studies, you should model particular groups of machines in the system that are known to have important influences on the system operation. The total simulation time for each study case should be sufficiently long to obtain a definite stability conclusion. Power System Stability Definition Power system stability is the property of a power system that insures the system remains in electromechanical equilibrium throughout any normal and abnormal operating conditions. Because the power system stability is an electromechanical phenomenon, it is thus defined as the ability of designated synchronous machines in the system to remain in synchronism with one another following disturbances such as fault and fault removal at various locations in the system. It also indicates the ability of induction motors in the system to maintain torque to carry load following these disturbances. Synchronous Machine Rotor Angles Synchronous machines play a decisive role in the power system stability because during and after disturbances their rotor angles will oscillate to cause power flow oscillations in the system. Depending on the level of these oscillations, the electromechanical equilibrium in the system could be destroyed and the instability could occur. Therefore, power system stability is sometimes also referred to as synchronous machine rotor angle stability. The following two equations are often referenced in power system transient stability studies: Torque Equation (Generator Case) where T = mechanical shaft torque P = number of poles φ air = air-gap flux F r = rotor field MMF δ = power (rotor) angle πp T = 8 2 φ air F r sin δ Operation Technology, Inc ETAP PowerStation 4.0

23 Calculation Methods The torque equation defines the relationship between the mechanical shaft torque, the stator voltage, the excitation system, and the rotor angle. Changes in any one of them will cause the rotor angle to readjust itself to a new position. Swing Equation (Generator Case) where M = inertia constant D = damping constant P mech = input mechanical power P elec = output electrical power 2 d δ dδ M + D = 2 dt dt P mech P elec The swing equation shows that the solution of the rotor angle is a function of balance between the mechanical power and the electrical power. Any change in the system that breaks this balance will cause the rotor angle to undergo a transient and reach a new position in an oscillatory manner. This oscillation is usually called the rotor angle swing. Stability Limits There are two types of stability limit for a power system, namely steady-state stability limit and transient stability limit. Steady-State Stability Limit The steady-state stability is defined as the stability of a system under conditions of gradual or small changes in the system. This stability can be either found by the load flow calculation for a steady-state operation, or determined by a transient stability study if there are system changes or disturbances involved. The system is said to be steady-state stable if, following any small and/or gradual disturbances, all synchronous machines reach their steady-state operating condition identical or close to the predisturbance operating conditions. The steady-state stability limit for any synchronous machine is when its rotor angle is less than 90 degrees. Transient Stability Limit Transient or dynamic stability is defined as the stability of a system during and after sudden changes or disturbances in the system, such as short-circuits, loss of generators, sudden changes in load, line tripping, or any other similar impact. The system is said to be transient stable if following a severe disturbance, all synchronous machines reach their steady-state operating condition without prolonged loss of synchronism or going out of step with other machines. Causes of Instability Problems The major causes to industrial power system instability problems include, but are not limited to: Short-circuits Loss of a tie connection to a utility system Loss of a portion of in-plant co-generation (generator rejection) Starting a motor that is large relative to the system generating capacity Switching operations of lines, capacitors, etc. Impact loading (motors and static loads) A sudden large step change of load or generation Operation Technology, Inc ETAP PowerStation 4.0

24 Calculation Methods Consequences of Instability Problems The consequences of power system instability problems usually are very severe and can range from permanent damage on equipment and shutting down processes, all the way to causing a whole area power outage. Some typical consequences are listed below: Area-wide blackout Interruption of loads Low-voltage conditions Damage to equipment Relay and protective device malfunctions Power System Transient Stability Enhancement Depending on the causes of instability problems in a particular system, a number of enhancements can be made to improve the system stability. Typical enhancements include: Improve configuration and system design. Increase synchronizing power Design and selection of rotating equipment use induction motors, increase moment of inertia, reduce transient reactance, improve voltage regulator and exciter characteristics Application of Power System Stabilizers (PSS) Add system protection fast fault clearance, system separation, etc. Add load shedding scheme However, note that each of the above remedies requires careful consideration and we recommend that you re-run all system studies again, because changes brought by those remedies very likely will impact system load flow, short-circuit, and motor starting results. Operation Technology, Inc ETAP PowerStation 4.0

25 Calculation Methods Simulation of Time Events and Actions Transient Stability study is essentially an action driven time-domain simulation. Actions should be specified at different time instants (events). There are two ways to specify events and actions. One way is to use the Event Editor and Action Editor in the Transient Stability Study Case Editor. Another way is to use relay-controlled dynamic actions. When using actions specified in the Transient Stability Study Case Editor, Action List, the exact time instant for the action to take place needs to be given. Type of actions in this category includes all the prescheduled operations such as generator start-up and shutdown, generator control mode change, load addition and rejection, motor acceleration, MOV start and others. When to simulate the system response for existing events, such as a recorded fault in the system, user also can use this type of action, because the recorded fault occurring time and duration are known. To specify this type of actions, user first creates a new event and the event occurring time in the Event Editor of the Transient Stability Study Case Editor, Event page, as shown below. Secondly, user can use the Action Editor in the same page to add as many actions as desired for this event. Operation Technology, Inc ETAP PowerStation 4.0

26 Calculation Methods A complete list of devices in ETAP PowerStation that can be specified with actions and types of these actions is given in section 2.2 Events Page, of this chapter, under subsection Actions. However, in power systems, many actions occur without any pre-acknowledgment, instead, they are controlled by sensors and relays. For instance, a current relay will trip off circuit breakers once the measured current by relay exceeds a pre-set value. In another case, a voltage relay can be used to open or close circuit breakers based on its monitored voltage and comparison with an upper and an lower settings. These types of action do not have a definite time of happening and are solely depending on the system dynamic responses and relay settings. They, therefore, have to be implemented using the second method, i.e., relay controlled actions. To use relay-controlled actions, user need to add a relay and connect it to the one-line diagram via a PT or CT, depending on type of the relay. Next in relay editor, user specifies relay-controlled circuit breaker ID, control settings, time delay, and other data related to relay operations. During the transient stability simulation in time-domain, if a relay setting is met, then its controlled circuit breaker will take an automatic action. This method avoids requesting to give a pre-defined action time and is a true resemblance to power system real operating conditions. Following two pictures give an example of how to use relay-controlled actions. In the first picture, assuming CB2 and/or CB11 are tripped off due to a fault in transformer T2, thus substation Sub2A-N losses power. To make a bus transfer for Sub2A-N to the adjacent bus Sub2B, user can place a voltage relay (27) on bus Sub2A-N to monitor the bus voltage magnitude and close a normally opened tie circuit breaker Tie CB when it is necessary. Operation Technology, Inc ETAP PowerStation 4.0

27 Calculation Methods To do so, user can set the voltage relay to pick up under-voltage at 65% and close Tie CB after 0.1 relay delaying time and what ever the closing cycle by Tie CB itself. Settings for the voltage relay is shown in the second figure down below. Operation Technology, Inc ETAP PowerStation 4.0

28 Required Data 17.5 Required Data To run a transient stability study, you need to provide all the data required for load flow calculation. In addition to that, you need to provide machine dynamic model data, load model data, and any control units, such as exciter and governor data. Required data for transient stability calculations include: Bus Data Bus ID Nominal kv Load Diversity Factor (when Loading option is set to Maximum or Minimum diversity factor) Branch Data 2-Winding and 3-Winding Transformers Transform ID Bus Connections Rated kv and MVA Impedance and tolerance X/R ratio Tap and LTC settings Phase Shift as in Standard Positive or Negative Sequence connections, or Special configurations Cable/Transmission Line Cable or Transmission Line ID Bus Connections Type, size, rated kv, # of conductors per phase, and length Use library data or enter cable's resistance, reactance, and susceptance values Impedance Impedance ID Bus Connections Resistance, reactance, and susceptance values Current-Limiting Reactor Current-Limiting Reactor ID Bus Connections X/R ratio, impedance, and tolerance Protective Device Data Protective Device ID Bus and Branch Connections Status CT/PT Data CT/PT ID Bus or Branch or Source or Load Connections Rating (Ratio) Operation Technology, Inc ETAP PowerStation 4.0

29 Required Data Relay Data Relay ID CT/PT Connections Device, CB ID, Action, Delay, Setting, Unit Power Grid Data Power Grid ID Bus Connections Operating mode (Swing, Voltage Control, or Mvar Control) Nominal kv %V and Angle for Swing mode %V, MW loading, and Mvar limits (Qmax & Qmin) for Voltage Control mode MW and Mvar loading for Mvar Control mode 3-Phase MVAsc and X/R values Synchronous Generator Data Synchronous generator ID Bus Connections Operating mode (Swing, Voltage Control or Mvar Control) Rated kv %V and Vangle for Swing mode of operation %V, MW loading, and Mvar limits (Qmax & Qmin) for Voltage Control mode of operation MW and Mvar loading for Mvar Control mode of operation Rated MVA Model type (None, Equivalent, Transient, or Subtransient) Machine type (Round-Rotor or Salient-Pole) Xd, Xd, Xd, Xq, Xl, X/R, Tdo for Equivalent model Xd, Xd, Xd, Xq, Xq, Xl, X/R, Tdo, Tqo for Transient model Round-Rotor machine type Xd, Xd, Xd, Xq, Xq, Xq, Xl, X/R, Tdo, Tdo, Tqo, Tqo for Subtransient model Round-Rotor machine type Xd, Xd, Xd, Xq (= Xq), Xq, Xl, X/R, Tdo for Transient model Salient-Pole machine type Xd, Xd, Xd, Xq, Xq (= Xq), Xq, Xl, X/R, Tdo, Tdo, Tqo for Subtransient model Salient-Pole machine type S100, S120, H, and Damping Sbreak for Generator Start-up Study Exciter Type and all associated parameters or fixed excitation Governor Type and all associated parameters or no governor action Power System Stabilizer (PSS) Type and all associated parameters or no PSS control Operation Technology, Inc ETAP PowerStation 4.0

30 Required Data Synchronous Motor Data Synchronous motor ID Bus Connections Quantity Rated kw/hp and kv Power factors and efficiencies at 100%, 75%, and 50% loadings Loading Category ID and % Loading Equipment cable data Model type (None, Equivalent, Transient or Subtransient) Machine type (Round-Rotor or Salient-Pole) Xd, Xd, Xd, Xq, Xl, X/R, Tdo for Equivalent model Xd, Xd, Xd, Xq, Xq, Xl, X/R, Tdo for Transient model Round-Rotor machine type Xd, Xd, Xd, Xq, Xq, Xq, Xl, X/R, Tdo, Tdo, Tqo, Tqo for Subtransient model Round-Rotor machine type Xd, Xd, Xd, Xq (= Xq), Xq, Xl, X/R, Tdo for Transient model Salient-Pole machine type Xd, Xd, Xd, Xq, Xq (= Xq), Xq, Xl, X/R, Tdo, Tdo, Tqo for Subtransient model Salient-Pole machine type S100, S120, H and Damping Exciter Type and all associated parameters or fixed excitation H Load model Induction Machine Data Induction machine ID Bus Connections Application type (motor or generator) Quantity Rated kw/hp and kv Power factors and efficiencies at 100%, 75%, and 50% loadings Loading Category ID and % Loading Equipment cable data Model type (None, Single1, Single2, DBL1, or DBL2) Xlr, Xoc, X/R, and Tdo for Single1 model Rs, Xs, Xm, Rr,fl, Rr,lr, Xr,fl, and Xr,lr for Single2 model Rs, Xs, Xm, Rrl, Rr2, Xr1, and Xr2 for DBL1 and DBL2 model H Load model % Start Loading for the First Starting Category (defines the motor start loading percent) Operation Technology, Inc ETAP PowerStation 4.0

31 Required Data MOV Data MOV ID Bus Connection Quantity Initial Status & Associated Demand Factor Rated kw/hp & kv Power Factor & Efficiency Rated Torque Hammer Blow & Micro Switch Flags Locked Rotor (LR), No Load (NL), Normal, & Rated Torque (Rated T) Time Duration Loading Category ID & % Loading Equipment Cable Data % Voltage Limit Static Load Data Static Load ID Bus Connection Quantity Status & Associated Demand Factor Rated kva/mva & kv Power Factor Loading Category ID & % Loading Equipment Cable Data Lumped Load Data Lumped Load ID Bus Connection Status & Associated Demand Factor Rated kva/mva & kv Power Factor % Motor Load & % Static Load Loading Category ID & % Loading Capacitor Data Capacitor ID Bus Connection Status & Associated Demand Factor Rated kv Mvar/Band and # of Bank Loading Category ID & % Loading Equipment Cable Data Operation Technology, Inc ETAP PowerStation 4.0

32 Required Data Harmonic Filter Harmonic Filter ID Filter Type Rated kv & 3-Phase kvar for Capacitors Xl & Q for Reactors R, if applicable Grounding Connection Grounding Type UPS Data UPS ID Bus Connection AC Connections Rated kw/mw & kv AC Input & Output Rated kv Power Factor & Efficiency Loading Category ID & % Loading VFD Data VFD ID Bus Connection VFD is Modeled as a Transparent Device in the Transient Stability Study Charger Data Charger ID Bus Connections Status & Associated Demand Factor AC Ratings Loading Category ID & % Loading Inverter Data Inverter is not Modeled in the Transient Stability Study Operation Technology, Inc ETAP PowerStation 4.0

33 Required Data Study Case Parameters Study Case ID Max. Number of Iterations Solution Precision Acceleration Factor Simulation Time Step Plot Time Step Initial Loading Category Initial Loading Condition (Loading Category, Operating Load) Load Diversity Factor (None, Bus Maximum, Bus Minimum, or Global) Charger Loading Condition (loading Category, Operating Load) Total Simulation Time Events & Actions Dynamic Modeling Information Starting Load Modeling Method Plots/Tabulated Selection Study Case parameters are entered into the Transient Stability Study Case Editor. Operation Technology, Inc ETAP PowerStation 4.0

34 Output Reports 17.6 Output Reports PowerStation provides transient stability study results at all different levels of detail, depending on your requirements. The results are reported in three different formats: a text output report, a one-line view display, and plots Transient Stability Report Manager Click on the View Output File button on the Transient Stability Toolbar to open the Transient Stability Report Manager. The Transient Stability Report Manager provides the format for text and consists of four pages. Complete Page From this page you can select the report format that gives you the complete output report. Currently, only the TextRept format is available. Input Page This page provides the formats for different input data. Currently, the formats in this page are not available for the transient stability study. Result Page This page provides the formats for different calculation results. Currently, the formats in this page are not available for the transient stability study. Summary Page This page provides the formats for different summaries from both input data and calculation results. Currently, the formats in this page are not available for the transient stability study. Operation Technology, Inc ETAP PowerStation 4.0

35 Output Reports Transient Stability Text Report The text output report can be viewed by clicking on the View Output File button in the Study Case Toolbar or from the Transient Stability Report Manager by selecting TextRept and clicking on OK. The transient stability analysis output report consists of several sections, as summarized below. Cover Page This is the first page of the output report. It includes information on the number of different types of buses, the number of different types of branches, the number of different types of machines; system parameters such as initial loading category, frequency, and unit system; solution parameters such as maximum iterations and solution precision; study parameters such as integration time step and plot time step, as well as output and plot file names. DYNAMIC STABILITY ANALYSIS Swing Gen. Load Total Number of Buses: XFRM XFRM3 React. Line Imp. C.B. SPDT Total Number of Branches: Synch. Synch. Ind. Uti- Gen. Motor Motor lity Total Number of Machines: Initial Loading: Design Maximum Number of Iterations: 2000 Solution Precision for the Initial LF: Acceleration Factor for the Initial LF: 1.45 Time Increment for Integration Steps: Sec. Time Increment for Plots: Sec. System Frequency: 60.0 Hz Unit System: English Data Filename: EXAMPLE Bus Input Data This section contains information for all the buses in the system, including bus ID, bus type (swing, generator, or load), nominal voltage, initial voltage magnitude and angle, MW and Mvar generation, Mvar limits, MW and Mvar motor load, MW and Mvar static load, etc. These data are the same as those in load flow output report and thus a sample printout is omitted. Branch Input Data This section contains the information for all branches in the system, including branch ID, R, X, Y, X/R, transformer tap and LTC, and all the related information on branch impedance. Branch connections are also reported. These data are the same as those in load flow output report, thus a sample printout is omitted. Operation Technology, Inc ETAP PowerStation 4.0

36 Output Reports Power Grid, Synchronous Machine Data This section contains the information for all utility equivalent machines, synchronous generators, and the dynamically modeled synchronous motors in the system, including machine ID, connected bus ID, machine type and model type, rated kv and MVA, impedance data, time constants, inertia, damping, and saturation factors. For synchronous motors, it also contains the information on the load model and parameters. Conned Bus Synch. GEN./MTR Rating (base) Machine Impedance ( % ) ============ ====================== =============== ============================================================== Bus ID Machine ID TYP MDL kv MVA Ra Xd" Xd' Xd Xq" Xq' Xq Xl Sub 2B Gen1 GEN Main Bus Utility UTL Sub 2B Syn1 MTR Bus3 Syn4 MTR Synch. GEN./MTR Time Constant (sec) H(sec), D(MWpu/Hz) & Sat. Gen./Loading ====================== ============================== ========================== ============== Machine ID TYP MDL Tdo" Tdo' Tqo" Tqo' H % D S100 S120 MW Mvar Gen1 GEN Syn1 MTR Syn4 MTR Synch. MTR Load Model ====================== ================================================ Machine ID TYP MDL Model ID A0 A1 A2 A Syn1 MTR 4 COMP CENT Syn4 MTR 4 Centr. Comp Exciter/AVR Data This section contains the information for all exciters installed in the system, including the generator ID to which the exciter is installed, exciter type, gains, time constants, and other parameters. Generator Type Time Constants (Sec.) and Parameters ============== ======== ================================================================================================== 1,2,3&1S KA KE KF TR TA TE TF/TF1 TF2/XL VRmax VRmin SEm/KP SE7/KI Efd/VB DC1 &DC2 KA KE KF TA TB TC TE TF TR VRmax VRmin SEmax SE75 Efd DC3 KE KV TE TR TRH VRmax VRmin SEmax SE75 Efd ST1, ST2 KA KC KE/KG KF/KJ KI KP KPreal KPimg TA TB TC TE TF TR & ST3 XL VGmax VImax VImin VRmax VRmin SEmax SE75 Efdmax AC1 &AC4 KA KC KD KE KF TA TB TC TE TF TR VAmax VAmin VImax VImin VRmax VRmin SEmax SE75 Efd AC2 &AC3 KA KB/KR KC KD KE KF KH/KN KL(V) TA TB TC TE TF TR VLR VLV Efdn VAmax VAmin VRmax VRmin SEmax SE75 Efd SR8F KA KF TR TA TB TF1 TF2 VRmax VRmin HPC 840 C D Kpow KQ KE Bmax Bmin Amax Amin VRmax VRmin SEmax SE75 Efd Te T4 TI TD TF Tdsty TP TQ CtlBus AC5A KA KE KF VRmax VRmin SEmax SE75 Efd TA1 TA2 TA3 TE TF1 TF2 TF3 TR JEUM Ar1 Ar2 Ku1 Ku2 Kif Kae Ke Vres Vsup SEm SE7 Efdmax Te Max1 Min1 Max2 Min2 Max3 Min3 Max4 Min4 Max5 Min5 Max6 Min6 Max7 Min7 Av1 Av2 Av3 Av4 Av5 Av6 Av7 Av8 Av9 Av10 Av11 Ai1 Ai2 Ai3 Ai4 Ai5 Ai6 Ai7 Ai8 Ai9 Ai10 Ai11 Ai12 ST1D KA KC KF KVF KVL TA TB TC TD TH TF TR TVL ID VImax VImin VRmax VRmin RC XC VVLR Vdc Rf VHZ Vfb Ifb Vref Gen Operation Technology, Inc ETAP PowerStation 4.0

37 Output Reports Governor/Turbine Data This section contains the information for all governors installed in the system, including generator ID to which the governor is installed, governor type, mode, gains, time constants, and other parameters. Type Operation Limits Time Constants(Sec.) and Parameters ====== ============= ============== ==================================================================== All ST %Droop Mode Pmax Pmin Tsr Tc Tch Trh1 Trh2 Tco Fhp Fvhp Fip GT&GP %Droop Mode Pmax Pmin Tsr Tc Tt Tdrp Ta DT,GTF %Droop Mode Pmax Pmin T1 T2 T3 T4 T5 T6 T7 T8 T9 &STM %Droop Mode Pmax Pmin K1/Kr K2/Kf K3/KD K4/Ff K5 K6 K7 DB UO/VU UC/VL UG8 Mode Pmax Pmin A1 A2 A3 B1 B2 C1 K1 Ad T7 T8 Generator GTH& Ki Mode Max. Min. X Y Z A/a B/b C/c D Kf T.Ctl A.Ctl GTS Tf/R Tcr/S Tcd/T Ttd T Tt Tr 505E Mode P1 I1 SDr1 L1 L2 Ta1 Tm1 Ts Prior Ramp ID HPa HPb HPc HPmax Sa Sb Sc Smax EFmax P2 I2 SDr2 L3 L4 Ta2 Tm2 EP EF 2301A %Droop Mode emax emin Alpha Beta Rho K1 Tao T1 T2 LS GP Pmax Pmin MARS %Droop Mode T1 T2 T3 T5 T6 T7 Ks Kt Ko Ku Kl MaxGv MinGv Maxo Mino Max2 Min2 Max3 Min3 DDEC %Droop Mode Pmax Pmin K1 K2 R1 Ts T1 T2 T3 GHH VLmax VLmin VMmax VMmin VHmax VHmin PLmax PLmin PMmax PMmin PHmax PHmin Kp1 Kp2 Kp3 Kp4 GL GM GH m1 m2 m3 e1 e2 HP MP Pa Pb Pc Pd Pe Pf LFa LFc LFd EX2f LFV1 LFV2 LFV3 LF1 LF2 LF3 FL0 KFL0 FL1 FM0 KFM0 FM1 Tn1 Tn2 Tn3 Tn5 Tn6 TL TM TH Esf1 Esf2 HYDR VO VC1 VC2 Gmax1 Gmax2 Gmin Q GC RP RT TP TG TR Zt Zp1 ft fp1 Tt Tp1 At1 Damp QNL Q2 RPM1 RPM2 RPM3 GBUFF Wref Href m B SGT Mode Pmax Pmin T1 T2 T3 T4 T5 T6 TR K1 K2 K3 Pref PL-A Fuel TP TL TQ TLD TLG TA TC TD TV TPL TPG TC1 TC2 TX1 TX2 TX3 TX4 TX5 KL KI KA KC KT DL JRL1 JRL2 TFLD Tref Plimit GOVBase ============ Gen1 ST1 5.0 Droop PSS Data This section contains the information for all PSS installed in the system, including generator ID to which the PSS is installed, PSS type, and all PSS parameters. Generator Type Time Constants (Sec.) and Parameters ============== ======== ================================================================================================== PSS1A KS VSTmax VSTmin VTmin TDR A1 A2 T1 T2 T3 T4 T5 T6 PSS2A KS1 KS2 KS3 VSTmax VSTmin VTmin TDR Tw1 Tw2 Tw3 Tw4 N M T1 ID T2 T3 T4 T5 T6 T7 T Gen1 PSS1A Operation Technology, Inc ETAP PowerStation 4.0

38 Output Reports Induction Machine Data This section contains the information for all dynamically modeled induction machines in the system, including machine ID, connected bus ID, rated kv and MVA, model type and model parameters, load model and model parameters, inertia, initial MW and Mvar loading, and slip. Conned Bus Ind. Motor Rating (base) Eqiv. Model (%Z & seconds) CKT or Double Cage Models (% impedance) ============ ================ ============== =========================== ================================================ Bus ID Machine ID MDL kv MVA Ra Xlr Xoc Tdo' Rs Xs Xm Rrfl,1 Rrlr,2 Xrfl,1 Xrlr, Bus3 Mtr2 CKT Sub3 Swgr Pump 1 CKT Conned Bus Ind. Motor H(sec) Load Model Normal Loading ============ ============ ====== ================================================ ============================== Bus ID Machine ID H Model ID A0 A1 A2 A3 % Slip MW Mvar % Load Bus3 Mtr a k*** Sub3 Swgr Pump FAN Initial Load Flow Report An initial load flow study is performed to determine all initial settings for machines, exciters/avrs, and governors/turbines with the specified initial loading condition. The initial load flow result is printed for you to inspect the system pre-event operating conditions. The format for the initial load flow report is similar to those of the load flow output report and thus a sample printout is omitted. Load Flow T=*.* This is the load flow report prior to the occurrence of a specified event. Following this section should be a detailed list of actions for the event. Note that for each event, there will be a corresponding pre-event load flow report. The format of this section is similar to those of the load flow output report and thus a sample printout is omitted. Event/Action Data This section lists detailed information on each action included in an event. This section appears right after a load flow report performed before this event and its associated actions occur. Bus / Machine Revision (Modification) ===================================== Bus/Mach ID Existing Type New Type Main Bus Swing Bus Faulted This page indicates bus/machine revisions occurring at simulation time T = seconds. Final Load Flow Report This is the load flow reported for the time at the end of the simulation. Formats of this section are similar to those of the load flow output report and thus a sample printout is omitted. Operation Technology, Inc ETAP PowerStation 4.0

39 Output Reports Tabulated Simulation Result This section tabulates, for each device that is selected for tabulation in the study case, the simulation results as functions of time at the specified plot time step. The type of tabulated results is the same as the plot curves, as defined in Plot Options. Gen. (Gen1 ) Syn. MT (Syn1 ) Syn. MT (Syn4 ) ====== ================================== ================================== ================================== Time Ang. Freq. Mech. Elec. Term. Ang. Freq. Mech. Elec. Term. Ang. Freq. Mech. Elec. Term. (Sec.) (deg) (Hz) (MW) (MW) I (A) (deg) (Hz) (MW) (MW) I (A) (deg) (Hz) (MW) (MW) I (A) TS Action Summary This section lists all the actions in the study, including both specified in the Transient Stability Study Case Editor and those initiated by relay actions. Device Action Time ============ ========== ======== Main Bus Faulted Main Bus Normal Operation Technology, Inc ETAP PowerStation 4.0

40 One-Line Diagram Displayed Results 17.7 One-Line Diagram Displayed Results In addition to the text report, PowerStation displays the transient stability calculation results on the oneline diagram. Transient Stability Time-Slider Once a transient stability study is completed, a Transient Stability Time-Slider, as shown below, will appear next to the Configuration & Mode Toolbar. The slider ranges from zero to the total simulation time. Initially, the reference pointer is at the far left, corresponding to t = 0 seconds. You may click on either end of the ruler to move the pointer one grid at a time, or hold the mouse button down to move the pointer continuously. You may also click on the pointer, hold the mouse button down, and then drag the pointer to the desired position. The time corresponding to the pointer position is also displayed next to the ruler in units of seconds. As you move the pointer along the slider, the displayed results change accordingly, providing you with a quick way to examine the calculation results. The one-line diagram displays are only available for those devices that are selected for plot options. Depending on the device type, different calculation results are displayed as defined below: Buses Voltage bus voltage magnitude in kv or percent Frequency bus frequency in Hz or percent Syn. Generators Power Angle synchronous generator rotor angle in degree or radian Frequency synchronous generator frequency in Hz or percent Efd synchronous generator field voltage in per unit Real and Reactive Power synchronous generator electrical power generation in kw+jkvar or MW+jMvar Apparent Power synchronous generator electrical power generation in kva or MVA Current synchronous generator terminal current in Amp Syn. Motors, MV Power Angle synchronous motor rotor angle in degree or radian Frequency synchronous motor frequency in Hz or percent Voltage synchronous motor terminal voltage in kv or percent Real and Reactive Power induction machine electrical power loading in kw+jkvar or MW+jMvar Apparent Power induction machine electrical power loading in kva or MVA Current induction machine terminal current in Amp Operation Technology, Inc ETAP PowerStation 4.0

41 One-Line Diagram Displayed Results Syn. Motors, LV Power Angle synchronous motor rotor angle in degree or radian Frequency synchronous motor frequency in Hz or percent Voltage synchronous motor terminal voltage in kv or percent Real and Reactive Power induction machine electrical power loading in kw+jkvar or MW+jMvar Apparent Power induction machine electrical power loading in kva or MVA Current induction machine terminal current in Amp Ind. Machines, MV Speed induction machine speed in RPM or percent slip Voltage induction machine terminal voltage in kv or percent Real and Reactive Power induction machine electrical power loading in kw+jkvar or MW+jMvar Apparent Power induction machine electrical power loading in kva or MVA Current induction machine terminal current in Amp Ind. Machines, LV Speed induction machine speed in RPM or percent slip Voltage induction machine terminal voltage in kv or percent Real and Reactive Power induction machine electrical power loading in kw+jkvar or MW+jMvar Apparent Power induction machine electrical power loading in kva or MVA Current induction machine terminal current in Amp MOV Real and Reactive Power mov electrical power loading in kw+jkvar or MW+jMvar Apparent Power mov electrical power loading in kva or MVA Current mov terminal current in Amp The units for the displayed results are defined in the Results Page of the Transient Stability Display Options. The following is a sample of one-line diagram display from the Transient Stability study. Operation Technology, Inc ETAP PowerStation 4.0

42 One-Line Diagram Displayed Results Operation Technology, Inc ETAP PowerStation 4.0

43 Plots 17.8 Plots PowerStation also provides simulation plots for you to examine Transient Stability calculation results in a graphic form. To view the plots, click on the Transient Stability Plots button on the Transient Stability Toolbar. It will bring up a dialog box for the Transient Stability Plot Selection, as shown below, from which you can specify the devices and types of plots to view. Device Type Select a device type for plotting. Device ID From this list, select the devices (up to 16 devices at a time) to be plotted. This list contains the devices that have been selected for plots from the study case editors. Plot Type Check plot type(s) for plot. Different device types have different plot types. Syn. Generators Power Angle synchronous generator power angle in degree Frequency synchronous generator frequency in Hz MWm synchronous generator shaft mechanical power generator in MW MWe synchronous generator electrical power generation in MW Current synchronous generator terminal current in Amp Efd synchronous generator field voltage in per unit Ifd synchronous generator field current in Amp Machine Z synchronous generator terminal impedance in % on machine base Operation Technology, Inc ETAP PowerStation 4.0

44 Plots Syn. Motors, MV (medium voltage motors) Power Angle synchronous motor power angle in degree Frequency synchronous motor frequency in Hz MWm synchronous motor mechanical power in MW MWe synchronous motor electrical power in MW Current synchronous motor terminal current in Amp Voltage synchronous motor connected bus voltage in % of the bus nominal kv Machine Z synchronous motor terminal impedance in % on machine base Syn. Motors, LV (low voltage motors) Power Angle synchronous motor power angle in degree Frequency synchronous motor frequency in Hz MWm synchronous motor mechanical power in MW MWe synchronous motor electrical power in MW Current synchronous motor terminal current in Amp Voltage synchronous motor connected bus voltage in % of the bus nominal kv Machine Z synchronous motor terminal impedance in % on machine base Ind. Machine, MV (medium voltage machines) Slip induction machine slip in % Accel Torque induction machine acceleration power in MW MWm induction machine mechanical power in MW MWe induction machine electrical power in MW Current induction machine terminal current in Amp Voltage induction machine connected bus voltage in % of the bus nominal kv Machine Z induction motor terminal impedance in % on machine base Ind. Machine, LV (low voltage machines) Slip induction machine slip in % Accel Torque induction machine acceleration power in MW MWm induction machine mechanical power in MW MWe induction machine electrical power in MW Current induction machine terminal current in Amp Voltage induction machine connected bus voltage in % of the bus nominal kv Machine Z induction motor terminal impedance in % on machine base Buses Voltage Angle bus voltage angle in degree Frequency bus frequency in % of system frequency MW bus real power loading in MW Mvar bus reactive power loading in Mvar Voltage/Hz bus voltage per Hz in volt/hz Voltage bus voltage magnitude in % of the bus nominal kv Operation Technology, Inc ETAP PowerStation 4.0

45 Plots MOVs Slip MOV slip in percent Acce l Power MOV acceleration power in kvar kvar MOV reactive power loading in kvar kw MOV real power loading in kw Current MOV current in Amp Voltage MOV terminal voltage in % of the connected bus nominal kv base Note that for synchronous motors and induction machines, terminal voltages are also displayed on the one-line diagram. The following is a set of sample plots from the Transient Stability study: Combine Plots Curves for the selected item will be plotted on the same graph. Multiple scales will be used. Operation Technology, Inc ETAP PowerStation 4.0

GARKANE ENERGY COOPERATIVE SMALL GENERATOR QUALIFIED FACILITY INTERCONNECTION APPLICATION

GARKANE ENERGY COOPERATIVE SMALL GENERATOR QUALIFIED FACILITY INTERCONNECTION APPLICATION Designated Contact Person: Mike Avant, Engineering Manager Address (for U.S. Mail Deliveries): Garkane Energy 1802 S Highway 89A Kanab, UT 84741 Telephone Number: (435) 644-5-26 E-Mail Address: mike.avant@garkane.com

More information

Form B GENERATION INTERCONNECTION APPLICATION (Non-Inverter Based Generation and Inverter Based Generation > 25 kw)

Form B GENERATION INTERCONNECTION APPLICATION (Non-Inverter Based Generation and Inverter Based Generation > 25 kw) Form B GENERATION INTERCONNECTION APPLICATION (Non-Inverter Based Generation and Inverter Based Generation > 25 kw) Preface: This Facility Connection Standard applies to any connection to Westar Energy's

More information

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form)

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) Attachment 2 Transmission Provider: Bluestem Electric Cooperative, Inc. Designated Contact Person: Kevin Heptig Address: P.O. Box 5, Wamego, Kansas

More information

Fault Current Contributions from Wind Plants Dean Miller PacifiCorp July 25, 2012

Fault Current Contributions from Wind Plants Dean Miller PacifiCorp July 25, 2012 Fault Current Contributions from Wind Plants Dean Miller PacifiCorp July 25, 2012 1 Presentation Overview Joint Working Group The Issue Structure of the Report Wind Plant Configuration Wind Turbine Generators

More information

Standard Development Timeline

Standard Development Timeline Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard is adopted by the NERC Board of Trustees (Board).

More information

Power Quality Improvement in Distribution System Using Distribution Static Compensator

Power Quality Improvement in Distribution System Using Distribution Static Compensator Power Quality Improvement in Distribution System Using Distribution Static Compensator Jay Kumar Sharma 1, Om Prakash Mahela 2 and Sunil Agarwal 1 1 Department of Electrical Engineering, Apex Institute

More information

TRANSMISSION PLANNING ASSESSMENT METHODOLOGY AND CRITERIA

TRANSMISSION PLANNING ASSESSMENT METHODOLOGY AND CRITERIA TRANSMISSION PLANNING ASSESSMENT METHODOLOGY AND CRITERIA For Compliance with NERC Reliability Standard: TPL-001-4 1/10/2017 Version: 4.2 Table of Contents 1 Revision and Approval History... 2 1.1 Revision

More information

Standard MH-TPL Transmission System Planning Performance Requirements

Standard MH-TPL Transmission System Planning Performance Requirements A. Introduction 1. Title: Transmission System Planning Performance Requirements 2. Number: MH-TPL-001-4 3. Purpose: Establish Transmission system planning performance requirements within the planning horizon

More information

Standard TPL Transmission System Planning Performance Requirements

Standard TPL Transmission System Planning Performance Requirements A. Introduction 1. Title: Transmission System Planning Performance Requirements 2. Number: TPL-001-4 3. Purpose: Establish Transmission system planning performance requirements within the planning horizon

More information

Standard Development Timeline

Standard Development Timeline Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard is adopted by the NERC Board of Trustees (Board).

More information

ISSN Vol.07,Issue.16, November-2015, Pages:

ISSN Vol.07,Issue.16, November-2015, Pages: ISSN 2348 2370 Vol.07,Issue.16, November-2015, Pages:3181-3185 www.ijatir.org Improvement of Power Quality in A Grid Connected Induction Generator Based Wind Farm using Static Compensator K. YOSHMA 1,

More information

Control of a Microgrid in Islanded Mode

Control of a Microgrid in Islanded Mode Faculty of Science & Engineering School of Engineering and Energy Control of a Microgrid in Islanded Mode A thesis submitted in partial fulfillment of the requirements for the degree of Bachelor of Engineering

More information

GUYANA POWER AND LIGHT INC

GUYANA POWER AND LIGHT INC GUYANA POWER AND LIGHT INC The Terms of Reference REQUEST FOR PROPOSALS: CONSULTANCY SERVICES COORDINATING GENERATOR PROTECTION WITH TRANSMISSION PROTECTION AND GENERATOR CONTROLS (GPL-PI-094-2016) November

More information

Interconnection Application

Interconnection Application Interconnection Application Persons interested in applying for the interconnection of a distributed energy resource to the Utility s distribution system through the Fast Track or Study Processes are to

More information

Standard Development Timeline

Standard Development Timeline Standard TPL-001-4 Transmission System Planning Performance Requirements Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be

More information

Transient Stability Analysis of an Industrial Cogeneration System

Transient Stability Analysis of an Industrial Cogeneration System Transient Stability Analysis of an Industrial Cogeneration System Hung-Cheng Chen Shang-Yi Chen Shun-Chung Shih Department of Electrical Engineering, National Chin-Yi University of Technology hcchen@ncut.edu.tw

More information

Connection Study Requirements

Connection Study Requirements Document Release Released: September 20, 2010 The Customer shall comply with all the applicable requirements in this document when performing connection studies to produce the engineering study report.

More information

Effects of Unbalanced Faults on Transient Stability of Cogeneration System

Effects of Unbalanced Faults on Transient Stability of Cogeneration System ffects of Unbalanced Faults on Transient Stability of Cogeneration System WI-NNG CHANG CHIA-HAN HSU Department of lectrical ngineering Chang Gung University 259 Wen-Hwa st Road, Kwei-Shan, Tao-Yuan, Taiwan,

More information

Generation Application Part B: Technical Form

Generation Application Part B: Technical Form Generation Connections Generation Application Part B: Technical Form For all applications with total installed generation capacity greater than 16A per phase (>4). 01 May 2018 How to fill out this application

More information

Information Document Protection System Information ID# R

Information Document Protection System Information ID# R Information Documents are for information purposes only and are intended to provide guidance. In the event of any discrepancy between the Information Document and the related authoritative document(s)

More information

Standard Development Timeline

Standard Development Timeline Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard is adopted by the NERC Board of Trustees (Board).

More information

Facility Interconnection Requirements

Facility Interconnection Requirements Facility Interconnection Effective 1/1/2016 1. Purpose Facility Interconnection Facility Interconnection (FAC-001-2) To avoid adverse impacts on the reliability of the Bulk Electric System (BES), RPU documents

More information

Rochelle Municipal Utilities TRANSMISSION PLANNING CRITERIA. March 21, 2017

Rochelle Municipal Utilities TRANSMISSION PLANNING CRITERIA. March 21, 2017 Rochelle Municipal Utilities TRANSMISSION PLANNING CRITERIA March 21, 2017 Contents 1 Background...3 2 National and Regional Criteria and Guides...4 2.1 2.1 NERC Transmission Planning Standards...4 2.2

More information

FERC Form No. 715 Part 4 TRANSMISSION PLANNING RELIABILITY CRITERIA

FERC Form No. 715 Part 4 TRANSMISSION PLANNING RELIABILITY CRITERIA FERC Form No. 715 Part 4 TRANSMISSION PLANNING RELIABILITY CRITERIA The following information submitted for this Part 4 of FERC Form No. 715 consists of PJM's current Planning Criteria, and each member

More information

PID275 Feasibility Study Report 9.33 MW Distribution Inter-Connection Valentine Substation

PID275 Feasibility Study Report 9.33 MW Distribution Inter-Connection Valentine Substation PID275 Feasibility Study Report 9.33 MW Distribution Inter-Connection Valentine Substation Prepared by: Entergy Services, Inc. T & D Planning 639 Loyola Avenue L-ENT-17A New Orleans, LA 70113 Rev Issue

More information

POTOMAC ELECTRIC POWER COMPANY

POTOMAC ELECTRIC POWER COMPANY POTOMAC ELECTRIC POWER COMPANY FERC Form 715 (Part 4) - Transmission Planning Study Guidelines Transmission Reliability Guidelines 1. General Overview The reliability guidelines used to plan the transmission

More information

What makes a Wind Plant Grid Friendly?

What makes a Wind Plant Grid Friendly? Stable Renewable Plant Voltage and Reactive Power Control NERC ERSTF June 11-12, 2014 Sebastian Achilles Nicholas Miller Einar Larsen Jason MacDowell GE Energy Consulting 1 / Topics Features of modern

More information

Distribution Information Exchange Code

Distribution Information Exchange Code Distribution Information Exchange Code Version 5.1 Approved September 2007 Comments to this document can be forwarded to: The RSA Grid Code Secretariat Attention: Mr. Bernard Magoro Eskom, Transmission

More information

Seminar on African Electrical Interconnection. Module 8 - Interconnected Systems Operating Conditions

Seminar on African Electrical Interconnection. Module 8 - Interconnected Systems Operating Conditions Seminar on African Electrical Interconnection Module 8 - Interconnected Systems Operating Conditions Module 8 - Interconnected Systems Operating Conditions Contents 1) Technical Operating Agreements 2)

More information

A. Introduction 1. Title: Automatic Underfrequency Load Shedding Requirements

A. Introduction 1. Title: Automatic Underfrequency Load Shedding Requirements A. Introduction 1. Title: Automatic Underfrequency Load Shedding Requirements 2. Number: PRC 006 RFC 01 3. Purpose: To establish ReliabilityFirst requirements for automatic Load shedding (UFLS) to support

More information

Connection of generation plant to distribution networks. Guidance on completing the application form

Connection of generation plant to distribution networks. Guidance on completing the application form Connection of generation plant to distribution networks It is possible to connect almost any generation plant to the distribution network and in order for the connection to meet the requirements of a new

More information

Investigation of Impacts of Solar PV on Transmission System Voltage Stability Considering Load Characteristics and Protection

Investigation of Impacts of Solar PV on Transmission System Voltage Stability Considering Load Characteristics and Protection 7th Solar Integration Workshop, 24-25 October 2017, Berlin, Germany Investigation of Impacts of Solar PV on Transmission System Voltage Stability Considering Load Characteristics and Protection Baheej

More information

Steady State Power System Security Analysis with PowerWorld Simulator

Steady State Power System Security Analysis with PowerWorld Simulator Steady State Power System Security Analysis with PowerWorld Simulator S8: Security Analysis for a Generator Interconnection Study 2001 South First Street Champaign, Illinois 61820 +1 (217) 384.6330 support@powerworld.com

More information

MEASUREMENTS AND SIMULATION FOR POWER QUALITY OF A WIND FARM

MEASUREMENTS AND SIMULATION FOR POWER QUALITY OF A WIND FARM Research Article MEASUREMENTS AND SIMULATION FOR POWER QUALITY OF A WIND FARM 1 S.P. Shukla, 2 Sushil Kumar Address for correspondence 1 Department of Electrical Engineering, Bhilai Institute of Technology,

More information

Daniel Feltes Phone: Fax:

Daniel Feltes Phone: Fax: Coordination of Controls of Renewable Power Plants to Meet Steady State and Dynamic Response Requirements for Voltage Control and Reactive Power Supply Dinemayer Silva Phone: 518-395-5169 Fax: 518-346-2777

More information

Reliability Standard Audit Worksheet 1

Reliability Standard Audit Worksheet 1 Reliability Standard Audit Worksheet 1 PER-006-1 Specific Training for Personnel This section to be completed by the Compliance Enforcement Authority. Audit ID: Registered Entity: NCR Number: Compliance

More information

Steady-state and transient voltage stability analysis of a weak distribution system with a remote doubly fed induction generator-based wind farm

Steady-state and transient voltage stability analysis of a weak distribution system with a remote doubly fed induction generator-based wind farm RESEARCH ARTICLE Steady-state and transient voltage stability analysis of a weak distribution system with a remote doubly fed induction generator-based wind farm Amit Kunwar, Ramesh Bansal 2 & Olav Krause

More information

Case Metrics 2015 Summer Base Case Quality Assessment Phase I Powerflow and Dynamics Case Quality Metrics FINAL

Case Metrics 2015 Summer Base Case Quality Assessment Phase I Powerflow and Dynamics Case Quality Metrics FINAL Case s 2015 Summer Base Case Quality Assessment Phase I Powerflow and Dynamics Case Quality s FINAL Introduction Powerflow and dynamics cases are the foundation of virtually all power system studies. Calculations

More information

DISTRIBUTION FEEDER PROTECTION WITH AND WITHOUT PV SYSTEM

DISTRIBUTION FEEDER PROTECTION WITH AND WITHOUT PV SYSTEM DISTRIBUTION FEEDER PROTECTION WITH AND WITHOUT PV SYSTEM 1 PADMAVATHY.P, 2 PARTHASARATHY.S Department of Electrical and Electronics Engineering, Valliammai Engineering College, Anna University, Chennai.

More information

EMTP Modeling of Cogeneration System for Transient Stability Analysis

EMTP Modeling of Cogeneration System for Transient Stability Analysis INTERNATIONAL JOURNAL OF ENERGY, Issue, ol. 6, 0 EMTP Modeling of Cogeneration System for Transient Stability Analysis Wei-Neng Chang, Abstract This paper focuses on the EMTP modeling of a cogeneration

More information

POWER SYSTEM STABILITY GUIDELINES

POWER SYSTEM STABILITY GUIDELINES PREPARED BY: DOCUMENT REF: Planning PSSG-02 VERSION: 1.0 DATE: 25 May 2012 FINAL Final Matt Zema CEO Date 25/ 5 /2012 Version Release History VERSION DATE AUTHOR PEER REVIEW APPROVED COMMENTS 1.0 25/5/12

More information

Problem specification

Problem specification 1 of 6 pages University of Rochester Department of Electrical & Computer Engineering ECE227/427 Take-home Exam due: 4-30-10 You are to work entirely alone on this take-home exam. NO COLLABORATION IS ALLOWED.

More information

Lesson Learned Loss of Wind Turbines due to Transient Voltage Disturbances on the Bulk Transmission System

Lesson Learned Loss of Wind Turbines due to Transient Voltage Disturbances on the Bulk Transmission System Lesson Learned Loss of Wind Turbines due to Transient Voltage Disturbances on the Bulk Transmission System Primary Interest Groups Balancing Authorities (BAs) Transmission Operators (TOPs) Generator Operators

More information

A. Introduction 1. Title: Automatic Underfrequency Load Shedding Requirements

A. Introduction 1. Title: Automatic Underfrequency Load Shedding Requirements A. Introduction 1. Title: Automatic Underfrequency Load Shedding Requirements 2. Number: PRC 006 RFC 01 3. Purpose: To establish ReliabilityFirst requirements for automatic underfrequency Load shedding

More information

ASSOCIATED NERC STANDARD(S): TPL (referred to as TPL-001 in this document) IMPLEMENTATION: In effect when approved.

ASSOCIATED NERC STANDARD(S): TPL (referred to as TPL-001 in this document) IMPLEMENTATION: In effect when approved. ASSOCIATED NERC STANDARD(S): TPL-001-4 (referred to as TPL-001 in this document) IMPLEMENTATION: In effect when approved. Phase in of individual TPL-001 requirements will be based on the effective dates

More information

Refinement of Hydel power by implementing FACTS at Narangwal hydroelectric power plant

Refinement of Hydel power by implementing FACTS at Narangwal hydroelectric power plant International Journal of Electronics Engineering Research. ISSN 0975-6450 Volume 9, Number 8 (2017) pp. 1323-1328 Research India Publications http://www.ripublication.com Refinement of Hydel power by implementing

More information

World Scientific Research Journal (WSRJ) ISSN: Research on Intelligent Microgrid and its Reliable Grid Connection

World Scientific Research Journal (WSRJ) ISSN: Research on Intelligent Microgrid and its Reliable Grid Connection World Scientific Research Journal (WSRJ) ISSN: 2472-3703 www.wsr-j.org Research on Intelligent Microgrid and its Reliable Grid Connection Xin Qiao a, * Department of Electrical Power Engineering, North

More information

Session 9: Photovoltaic System Case Studies And Electric Distribution Planning for DER October 21, 2015 Santiago, Chile

Session 9: Photovoltaic System Case Studies And Electric Distribution Planning for DER October 21, 2015 Santiago, Chile Session 9: Photovoltaic System Case Studies And Electric Distribution Planning for DER October 21, 2015 Santiago, Chile Michael Coddington National Renewable Energy Laboratory Golden, Colorado, U.S.A.

More information

Generator Interconnection Affected System Impact Study. Plains & Eastern Clean Line Final Report

Generator Interconnection Affected System Impact Study. Plains & Eastern Clean Line Final Report Generator Interconnection Affected System Impact Study Plains & Eastern Clean Line Final Report May 19, 2015 MISO 2985 Ames Crossing Eagan Minnesota - 55121 http://www.misoenergy.org Midcontinent Independent

More information

ISSN Vol.09,Issue.04, March-2017, Pages:

ISSN Vol.09,Issue.04, March-2017, Pages: ISSN 2348 2370 Vol.09,Issue.04, March-2017, Pages:0558-0562 www.ijatir.org Simulation Exhibition of 220KW Wind Power Generation with PMSG Using Matlab Simulink K. INDRANI 1, DR. K. RAVI 2, S. SENTHIL 3

More information

Delaware Electric Cooperative Generator Interconnection Application Long Form (For Use with Generators Greater than 100 kw)

Delaware Electric Cooperative Generator Interconnection Application Long Form (For Use with Generators Greater than 100 kw) An applicant (Generator Owner) makes application to to install and operate a generating facility greater than 100 kw interconnected with the utility system. Section 1, Applicant Information Directly Interconnected

More information

Galaxy 300. Operation 05/

Galaxy 300. Operation 05/ Galaxy 300 60 80 kva Operation 05/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred to in this guide

More information

ATTACHMENT P SMALL GENERATOR INTERCONNECTION PROCEDURES (SGIP) (For Generating Facilities No Larger Than 20 MW)

ATTACHMENT P SMALL GENERATOR INTERCONNECTION PROCEDURES (SGIP) (For Generating Facilities No Larger Than 20 MW) ATTACHMENT P SMALL GENERATOR INTERCONNECTION PROCEDURES (SGIP) (For Generating Facilities No Larger Than 20 MW) Section 1 Application 1.1 Applicability 1.1.1 A request to interconnect a certified Small

More information

Distributed Renewable Energy Generation Interconnection Policy

Distributed Renewable Energy Generation Interconnection Policy Distributed Renewable Energy Generation Interconnection Policy Dominica Electricity Services 2010 Version Table of Contents Executive Summary... 2 1. Interconnection Policy... 6 1.1 Introduction... 6 1.2

More information

ReliabilityFirst Regional Criteria 1. Verification and Data Reporting of Generator Gross and Net Reactive Power Capability

ReliabilityFirst Regional Criteria 1. Verification and Data Reporting of Generator Gross and Net Reactive Power Capability ReliabilityFirst Regional Criteria 1 Verification and Data Reporting of Generator Gross and Net Reactive Power Capability 1 A ReliabilityFirst Board of Directors approved good utility practice document

More information

Low SCR Wind Identification and Mitigation. Will Lovelace MIPSYCON 2015 November 11 th, 2015

Low SCR Wind Identification and Mitigation. Will Lovelace MIPSYCON 2015 November 11 th, 2015 Low SCR Wind Identification and Mitigation Will Lovelace MIPSYCON 2015 November 11 th, 2015 System Background - Diagram System Background - Diagram System Background - Description 199.5 MW wind farm on

More information

NERC PLANNING STANDARDS

NERC PLANNING STANDARDS NERC PLANNING STANDARDS North American Electric Reliability Council April 2004 Version of All Planning Standards Terms and Their Definitions As Used in the Analysis (Study) an examination or simulation

More information

Generator Assessment & Roles During A Restoration

Generator Assessment & Roles During A Restoration Generator Assessment & Roles During A Restoration PJM State & Member Training Dept. PJM 2015 Objectives Students will be able to: Identify the process and requirements for operating during system restoration

More information

FACILITY CONNECTION REQUIREMENTS NERC TO-FAC 001-0

FACILITY CONNECTION REQUIREMENTS NERC TO-FAC 001-0 FACILITY CONNECTION REQUIREMENTS NERC TO-FAC 001-0 TABLE OF CONTENTS (NERC TO-FAC-001-0) Facility Connection Requirements Introduction Procedures for Coordinated Joint Studies...1 Procedures for Notification...1

More information

Galaxy 300 and Galaxy 300i

Galaxy 300 and Galaxy 300i Galaxy 300 and Galaxy 300i 10-40 kva 380/400/415 V Operation 07/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries

More information

WIND TURBINES IN WEAK GRIDS CONSTRAINTS AND SOLUTIONS. J O G Tande and K Uhlen. SINTEF Energy Research, Norway SUMMARY

WIND TURBINES IN WEAK GRIDS CONSTRAINTS AND SOLUTIONS. J O G Tande and K Uhlen. SINTEF Energy Research, Norway SUMMARY WIND TURBINES IN WEAK GRIDS CONSTRAINTS AND SOLUTIONS J O G Tande and K Uhlen SINTEF Energy Research, Norway SUMMARY Cost efficient utilisation of the wind energy resource requires wind farms to be located

More information

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists 3,800 116,000 120M Open access books available International authors and editors Downloads Our

More information

Daker DK kva. Parallel installation quick start. Part. LE08927AA-09/15-01 GF

Daker DK kva. Parallel installation quick start. Part. LE08927AA-09/15-01 GF Daker DK 4.5-10 kva Parallel installation quick start Part. LE08927AA-09/15-01 GF Daker DK 4.5-10 kva UK ENGLISH 3 2 Daker DK 4.5-10 kva Index Introduction 2 1 Important Safety Instructions 2 2 Parallel

More information

AMERICAN RENEWABLES GAINESVILLE REGIONAL UTILITIES GAINESVILLE RENEWABLE ENERGY CENTER

AMERICAN RENEWABLES GAINESVILLE REGIONAL UTILITIES GAINESVILLE RENEWABLE ENERGY CENTER AMERICAN RENEWABLES GAINESVILLE REGIONAL UTILITIES --------------------------------------------- GAINESVILLE RENEWABLE ENERGY CENTER OPERATING PROCEDURES Revision 0; September 1, 2012 Revision 1; November

More information

University of Strathclyde Faculty of Engineering

University of Strathclyde Faculty of Engineering University of Strathclyde Faculty of Engineering Energy Systems and the Environment: Part A Examination Monday 19 January 2004 14.00-17.00, M329 Full-time students should attempt FOUR questions, 1 from

More information

SMALL GENERATOR INTERCONNECTION PROCEDURES (SGIP) (For Generating Facilities No Larger Than 20 MW)

SMALL GENERATOR INTERCONNECTION PROCEDURES (SGIP) (For Generating Facilities No Larger Than 20 MW) The revisions to this document take effect August 28, 2006, per FERC Order No. 2006-B issued July 20, 2006, FERC Stats. & Regs. 31,221, which was published in the Federal Register July 27, 2006 (71 FR

More information

BASIC CONCEPTS. Yahia Baghzouz Electrical & Computer Engineering Department

BASIC CONCEPTS. Yahia Baghzouz Electrical & Computer Engineering Department BASIC CONCEPTS Yahia Baghzouz Electrical & Computer Engineering Department INSTANTANEOUS VOLTAGE, CURRENT AND POWER, RMS VALUES AVERAGE (REAL) POWER, REACTIVE POWER, APPARENT POWER, POWER FACTOR INSTANTANEOUS

More information

DISTRIBUTED RENEWABLE ENERGY GENERATION POLICY

DISTRIBUTED RENEWABLE ENERGY GENERATION POLICY DISTRIBUTED RENEWABLE ENERGY GENERATION POLICY Dominica Electricity Services 2016 Version 2.00 DOCUMENT TITLE AND APPROVAL PAGE DOCUMENT NUMBER: 2016/002/D DOCUMENT TITLE: DISTRIBUTED RENEWABLE ENERGY

More information

Transmission Losses Report 2015

Transmission Losses Report 2015 SP Energy Networks October 2015 Transmission Losses Report 2015 1. INTRODUCTION Special condition 2K of SPT s transmission licence requires SPT to publish an annual transmission losses report detailing

More information

AMERICAN RENEWABLES GAINESVILLE REGIONAL UTILITIES GAINESVILLE RENEWABLE ENERGY CENTER

AMERICAN RENEWABLES GAINESVILLE REGIONAL UTILITIES GAINESVILLE RENEWABLE ENERGY CENTER AMERICAN RENEWABLES GAINESVILLE REGIONAL UTILITIES --------------------------------------------- GAINESVILLE RENEWABLE ENERGY CENTER OPERATING PROCEDURES Revision 0; September 1, 2012 Revision 1; November

More information

International ejournals

International ejournals ISSN 2249 5460 Available online at www.internationalejournals.com International ejournals International Journal of Mathematical Sciences, Technology and Humanities 21 (2011) 205 212 ENERGY CONTROL CENTER

More information

Phasor measurement units gain credibility through improved test and calibration standards

Phasor measurement units gain credibility through improved test and calibration standards Phasor measurement units gain credibility through improved test and calibration standards Smart grid; PMU calibration position 1 The North American interconnection, or electric transmission grid, is a

More information

RiskyProject Lite 7. Getting Started Guide. Intaver Institute Inc. Project Risk Management Software.

RiskyProject Lite 7. Getting Started Guide. Intaver Institute Inc. Project Risk Management Software. RiskyProject Lite 7 Project Risk Management Software Getting Started Guide Intaver Institute Inc. www.intaver.com email: info@intaver.com Chapter 1: Introduction to RiskyProject 3 What is RiskyProject?

More information

Impacts of the Decentralized Wind Energy Resources on the Grid

Impacts of the Decentralized Wind Energy Resources on the Grid 21, rue d Artois, F-75008 PARIS CIGRE US National Committee http : //www.cigre.org 2013 Grid of the Future Symposium Impacts of the Decentralized Wind Energy Resources on the Grid Babak Enayati, PhD, Senior

More information

Transmission Planning Standards for the Baltimore Gas & Electric Company Transmission System

Transmission Planning Standards for the Baltimore Gas & Electric Company Transmission System Transmission Planning Standards for the Baltimore Gas & Electric Company Transmission System Prepared By: Transmission Planning Unit Baltimore Gas & Electric Company Table of Contents Page I. Introduction...

More information

Remote AMD Operator Manual

Remote AMD Operator Manual Remote AMD Operator Manual SOFTWARE Remote AMD V1.0.3 User manual (English) Project name: Project: Order / Project NO.: 1-2 Index 1. Introduction ---------------------------------------------------- 1-4

More information

LSA 42.3 Low Voltage Alternators - 4 pole

LSA 42.3 Low Voltage Alternators - 4 pole LSA 42.3 Low Voltage Alternators - 4 pole 2 to 60 kva - 0 Hz / 31. to 7 kva - 60 Hz Electrical and mechanical data Specially adapted to applications The LSA 42.3 alternator is designed to be suitable for

More information

Principles of modeling large wind parks

Principles of modeling large wind parks Doctoral school of energy- and geo-technology January 16 1 006. Kuressaare Estonia Principles of modeling large wind parks Raivo Attikas doctoral student.c. Tallinn University of Technology Department

More information

NZQA registered unit standard version 6 Page 1 of 6

NZQA registered unit standard version 6 Page 1 of 6 Page 1 of 6 Title Operate hydro-electric generating plant on site Level 4 Credits 8 Purpose People credited with this unit standard are able to: demonstrate knowledge of the principles of hydro-electric

More information

Dated: April 16, 2002

Dated: April 16, 2002 Central Hudson Gas & Electric Corporation (CHG&E) Application Process for Distributed Generators of Greater than 300 kva Connected in Parallel with the CHG&E Electrical Delivery System Dated: April 16,

More information

The strongest link. Captive power plant-smelter interface for increased power plant efficiency. Reprint from ABB Review 4/2007

The strongest link. Captive power plant-smelter interface for increased power plant efficiency. Reprint from ABB Review 4/2007 The strongest link Captive power plant-smelter interface for increased power plant efficiency Reprint from ABB Review 4/2007 Power Plant Picture Courtesy by Alstom The strongest link Captive power plant-smelter

More information

Platte River Power Authority. Ten-Year Transmission Plan ( )

Platte River Power Authority. Ten-Year Transmission Plan ( ) Platte River Power Authority Ten-Year Transmission Plan (2015-2024) Prepared by PRPA System Planning December 31, 2014 Table of Contents I. Executive Summary II. III. IV. Scope Assumptions Criteria V.

More information

Electric Power Systems An Overview. Y. Baghzouz Professor of Electrical Engineering University of Nevada, Las Vegas

Electric Power Systems An Overview. Y. Baghzouz Professor of Electrical Engineering University of Nevada, Las Vegas Electric Power Systems An Overview Y. Baghzouz Professor of Electrical Engineering University of Nevada, Las Vegas Overview Power Generation Conventional and renewable power generation Power transmission

More information

J. Electrical Systems 10-2 (2014): Regular paper IMPACT OF INCREASED DISTRIBUTED GENERATION ON FAULT LEVELS AND THE NETWORK EQUIPMENT

J. Electrical Systems 10-2 (2014): Regular paper IMPACT OF INCREASED DISTRIBUTED GENERATION ON FAULT LEVELS AND THE NETWORK EQUIPMENT Yaminidhar Reddy Bhavanam 1 Mohammad Shahrazad 2 J. Electrical Systems 10-2 (2014): 209-222 Regular paper IMPACT OF INCREASED DISTRIBUTED GENERATION ON FAULT LEVELS AND THE NETWORK EQUIPMENT JES Journal

More information

Wind turbine model validation with measurements

Wind turbine model validation with measurements 9 th Deep Sea Offshore Wind R&D Seminar, 19-20 January 2012, Trondheim Wind turbine model validation with measurements - Comparison between measured and simulated responses to voltage dips in the grid

More information

SOFTWARE FOR WINDOWS 2019 PRICE LIST. The Leader in Electrical Engineering Software Chosen by the top 40 Electrical Engineering firms in the world.

SOFTWARE FOR WINDOWS 2019 PRICE LIST. The Leader in Electrical Engineering Software Chosen by the top 40 Electrical Engineering firms in the world. ENGINEERING POWER*TOOLS ELECTRICAL SOFTWARE FOR WINDOWS 2019 PRICE LIST The Leader in Electrical Engineering Software Chosen by the top 40 Electrical Engineering firms in the world. Electrical Engineering

More information

This section applies to the requirements for electrical Inspection, calibration, and testing.

This section applies to the requirements for electrical Inspection, calibration, and testing. Basis of Design This section applies to the requirements for electrical Inspection, calibration, and testing. Design Criteria Edit attached guide specification, as required, to meet the project requirements.

More information

RiskyProject Lite 7. User s Guide. Intaver Institute Inc. Project Risk Management Software.

RiskyProject Lite 7. User s Guide. Intaver Institute Inc. Project Risk Management Software. RiskyProject Lite 7 Project Risk Management Software User s Guide Intaver Institute Inc. www.intaver.com email: info@intaver.com 2 COPYRIGHT Copyright 2017 Intaver Institute. All rights reserved. The information

More information

Integration issues and simulation challenges of high penetration PV

Integration issues and simulation challenges of high penetration PV Integration issues and simulation challenges of high penetration PV March 6, 2014 EnerNex Capabilities Power Systems Modeling Transient Analysis Our preferred tools: EMTP RV, PSCAD Steady State & Quasi

More information

Low Voltage alternators - 4 pole LSA 42.3

Low Voltage alternators - 4 pole LSA 42.3 Low Voltage alternators - 4 pole LSA 42.3 2 to 60 kva - 0 Hz / 31. to 7 kva - 60 Hz Electrical and mechanical data 42en - 12.02 / c SPECIALLY ADAPTED TO APPLICATIONS The LSA 42.3 alternator is designed

More information

ANAFAS is a short-circuit calculation

ANAFAS is a short-circuit calculation ANAFAS Simultaneous Fault Analysis ANAFAS is a short-circuit calculation software that covers a wide range of automated fault simulations. Its output reports are guided by fault points or monitoring points.

More information

Modeling of a Vertical Axis Wind Turbine with Permanent Magnet Synchronous Generator for Nigeria

Modeling of a Vertical Axis Wind Turbine with Permanent Magnet Synchronous Generator for Nigeria International Journal of Engineering and Technology Volume 3 No. 2, February, 2013 Modeling of a Vertical Axis Wind Turbine with Permanent Magnet Synchronous Generator for Nigeria B.O.Omijeh, C. S. Nmom,

More information

WIND ENERGY GENERATION

WIND ENERGY GENERATION WIND ENERGY GENERATION Modelling and Control Olimpo Anaya-Lara, University of Strathclyde, Glasgow, UK Nick Jenkins, Cardiff University, UK Janaka Ekanayake, Cardiff University, UK Phill Cartwright, Rolls-Royce

More information

SYNOPSIS OF THE THESIS. Enhanced Power Quality Management of Grid Connected Wind Farm

SYNOPSIS OF THE THESIS. Enhanced Power Quality Management of Grid Connected Wind Farm SYNOPSIS OF THE THESIS Enhanced Power Quality Management of Grid Connected Wind Farm INTRODUCTION OF THE THESIS Faster depletion of fossil fuels and environmental damage has resulted into increased use

More information

MATL Requirements Facility Interconnection Requirements

MATL Requirements Facility Interconnection Requirements Table of Contents 1. Purpose... 2 2. References... 2 3. Responsibility... 2 4. Interconnection Criteria... 3 4.1 R3.1. & R3.2. Procedures for Coordinated Studies and Notification of New or Materially Modified

More information

Agilent Quality Tool Online Help. Printable Version. Intelligent Test Software Solutions. ITFSS p January 2005

Agilent Quality Tool Online Help. Printable Version. Intelligent Test Software Solutions. ITFSS p January 2005 Agilent Quality Tool Online Help Printable Version Intelligent Test Software Solutions ITFSS 03.10 p 1204 January 2005 Agilent Quality Tool Online Help: Printable Version 1 Copyrights and Notices Agilent

More information

CONTINUOUS POWER-TIE CONFIGURATION

CONTINUOUS POWER-TIE CONFIGURATION POWER AVAILABILITY CONTINUOUS POWER-TIE CONFIGURATION USER MANUAL Series 610 Multi-Module UPS TABLE OF CONTENTS 1.0 SYSTEM DESCRIPTION....................................................1 1.1 Function...................................................................

More information

POWER QUALITY ASPECTS IN A WIND POWER PLANT IMAMHUSEN M PATIL. MASTER OF TECHNOLOGY IN ELECTRICAL ENGINEERING (Computer Controlled Industrial Power)

POWER QUALITY ASPECTS IN A WIND POWER PLANT IMAMHUSEN M PATIL. MASTER OF TECHNOLOGY IN ELECTRICAL ENGINEERING (Computer Controlled Industrial Power) POWER QUALITY ASPECTS IN A WIND POWER PLANT A THESIS Submitted by IMAMHUSEN M PATIL In partial fulfillment for the award of the Degree of MASTER OF TECHNOLOGY IN ELECTRICAL ENGINEERING (Computer Controlled

More information

Adjoint wind turbine modeling with ADAMS, Simulink and PSCAD/EMTDC

Adjoint wind turbine modeling with ADAMS, Simulink and PSCAD/EMTDC NORDIC WIND POWER CONFERENCE, 1- MARCH, 4, CHALMERS UNIVERSITY OF TECHNOLOGY 1 Adjoint wind turbine modeling with ADAMS, Simulink and PSCAD/EMTDC Sanna Uski, Bettina Lemström, Juha Kiviluoma, Simo Rissanen

More information

GATE SOLUTIONS. From ( ) Office : F-126, (Lower Basement), Katwaria Sarai, New Delhi Phone :

GATE SOLUTIONS. From ( ) Office : F-126, (Lower Basement), Katwaria Sarai, New Delhi Phone : GATE SOLUTIONS E L E C T R I C A L E N G I N E E R I N G From (1991-017) Office : F-16, (Lower Basement), Katwaria Sarai, New Delhi-110016 Phone : 011-65064 Mobile : 81309090, 9711853908 E-mail: info@iesmasterpublications.com,

More information