1 Installing and Using the HAND-HELD BARCODE SCANNER VITROS 5600 Integrated System VITROS 3600 Immunodiagnostic System VITROS 5,1 FS Chemistry System VITROS 4600 Chemistry System Pub. No.: J55820EN Purpose: IMPORTANT: Install and use the HAND-HELD BARCODE SCANNER to manually scan sample barcodes and configured quality control barcodes when there is no Lab Information System (LIS) or to scan VITROS MicroTip reagent pack barcodes and VITROS MicroWell reagent pack barcodes during a manual load. THE BARCODE SCANNER CANNOT BE USED TO SCAN BARCODES ON SLIDE CARTRIDGES. Materials required: BARCODE SCANNER with CABLES BARCODE SCANNER STAND BARCODE CONFIGURATION SHEET IMPORTANT: WAIT UNTIL ASSAY PROCESSING COMPLETES BEFORE YOU PERFORM THIS PROCEDURE. 1. Shut down the system. 2. Move the KEYBOARD aside, and then feed the 2 SCANNER CABLES up through the hole in the bottom of the TRAY ARM.
2 3. Disconnect the KEYBOARD CABLE, and then connect each end of the KEYBOARD CABLE to the corresponding SCANNER CABLE. 4. Set the KEYBOARD back in place. 5. Restart the system. 6. From the Main Menu, touch Options & Configurations Configure System PSID. 7. When the system displays the Configure PSID Checkdigit dialog box, note which option or combination of options ( Code 39, Codabar, and/or IL 2 of 5 ) are enabled for Checkdigit. 8. Scan the barcode(s) on the CONFIGURATION SHEET that correspond to selected Check Digit options on your system. The CONFIGURATION SHEET has been included with the BARCODE SCANNER packaging and is also presented below. Each pair of barcodes on the sheet is assigned a number and system dialog screenshot as shown below: 2 Installing and Using the HAND-HELD BARCODE SCANNER Pub No.: J55820EN
3 Checkdigit not enabled Checkdigit enabled The numbers on the CONFIGURATION SHEET correspond to the numbers and descriptions in the following table: Code 39 without checkdigit (Scan both barcodes) Codabar without checkdigit (Scan both barcodes) Interleaved 2 of 5 without checkdigit (Scan both barcodes) Code 39 with checkdigit (Scan both barcodes) Codabar with checkdigit (Scan both barcodes) Interleaved 2 of 5 with checkdigit (Scan both barcodes) Note: Scan from top to bottom if using more than one pair of barcodes. Pub No.: J55820EN Installing and Using the HAND-HELD BARCODE SCANNER 3
4 Here are two examples that show how to use the Configure PSID Checkdigit dialog box and the table of numbers and descriptions to determine which barcodes may be scanned: Example 1 The Code 39 checkbox is checked, but the Codabar and "IL 2 of 5 checkboxes are not checked. In this situation, you can scan the following barcodes: 4 Installing and Using the HAND-HELD BARCODE SCANNER Pub No.: J55820EN
5 Example 2 No checkboxes are checked. In this situation, you can scan the following barcodes: Pub No.: J55820EN Installing and Using the HAND-HELD BARCODE SCANNER 5
6 9. Place the SCANNER STAND where the SCANNER CABLE will not interfere with DOORS, COVERS, or normal system operation. Ortho Clinical Diagnostics 100 Indigo Creek Drive Rochester, NY Pub. No.: J55820EN All trademarks are registered to Ortho-Clinical Diagnostics, Inc. Ortho-Clinical Diagnostics, Inc Installing and Using the HAND-HELD BARCODE SCANNER Pub No.: J55820EN
Normalization, Dilution and Transfer Methods for the Maxprep TM Liquid Handler Technical Manual
Normalization, Dilution and Transfer Methods for the Maxprep TM Liquid Handler Technical Manual Instructions for use of Products AS9100, AS9101, AS9200, AS9201 TM530 11/17 Table of Contents 1 Description...2
More informationIn-Lab Training Manual
In-Lab Training Manual UniCel DxC Synchron Access Clinical System Integrated Workstations For In Vitro Diagnostic Use This manual is intended for UniCel DxC 660i UniCel DxC 680i UniCel DxC 860i UniCel
More informationcobas p 512 pre-analytical system Adapting to today s needs. Flexible for tomorrow s demand.
cobas p 512 pre-analytical system Adapting to today s needs. Flexible for tomorrow s demand. Personalized Lab Automation Maximizing testing efficiency and medical value Hospital network At Roche, laboratory
More informationcobas p 512 pre-analytical system Adapting to today s needs. Flexible for tomorrow s demand.
cobas p 512 pre-analytical system Adapting to today s needs. Flexible for tomorrow s demand. Personalized Lab Automation Maximizing Testing Efficiency and Medical Value At Roche, laboratory automated solutions
More informationFULLY AUTOMATED ENZYME IMMUNOASSAY ANALYZER AUTOMATED IMMUNOASSAY ANALYZER. Advanced Immunoassay Testing TOSOH BIOSCIENCE
FULLY AUTOMATED ENZYME IMMUNOASSAY ANALYZER AUTOMATED IMMUNOASSAY ANALYZER Advanced Immunoassay Testing TOSOH BIOSCIENCE Soar Through Your Immunoassay Testing Challenges Throughput of 200 results per hour
More informationAdvanced Immunoassay Testing
Symmetry in Diagnostics FULLY AUTOMATED ENZYME IMMUNOASSAY ANALYZER Advanced Immunoassay Testing TOSOH BIOSCIENCE www.tosohbioscience.us High Powered and Flexible Immunoassay Testing Throughput of 200
More informationBio-Rad Laboratories BIOPLEX 2200 SYSTEM. BioPlex 2200 System. Workflow: Redefined
BioPlex 2200 System Workflow: Redefined Workflow: Redefined Leveraging the power of multiplex testing, the BioPlex 2200 system brings flexible workflow solutions to your laboratory. Disease Focused Multiplex
More informationcobas p 612 pre-analytical system Adapting to today s needs. Flexible for tomorrow s demand.
cobas p 612 pre-analytical system Adapting to today s needs. Flexible for tomorrow s demand. Personalized Lab Automation Maximizing Testing Efficiency and Medical Value At Roche, laboratory automated solutions
More informationINSTRUCTIONS FOR USE
INSTRUCTIONS FOR USE VITROS Chemistry Products Fe Slides Fe 151 5808 192 4547 Caution: Rx ONLY Intended Use For in vitro diagnostic use only. VITROS Chemistry Products Fe Slides quantitatively measure
More informationMagister C24 BECAUSE SMALL IS OUR CHALLENGE! The world s first small fully automated blood group analyser RESEARCH DIAGNOSTICS PHARMACEUTICALS
Magister C24 The world s first small fully automated blood group analyser BECAUSE SMALL IS OUR CHALLENGE! RESEARCH DIAGNOSTICS PHARMACEUTICALS For labs with low throughput Magister C24 is specifically
More informationPathology Solution IVD US. Philips IntelliSite HER2/neu IHC Digital Manual Read
Pathology Solution IVD US Philips IntelliSite HER2/neu IHC Digital Manual Read Multisite configuration Role based User access control Single worklist view across the sites Real-time Collaboration & Sharing
More informationTrue Walkaway Automated Urinalysis, Chemistry to Microscopy The CLINITEK AUWi System Answers for life.
www.siemens.com/diagnostics True Walkaway Automated Urinalysis, Chemistry to Microscopy The CLINITEK AUWi System Answers for life. Can I achieve true unattended urinalysis testing in my laboratory? With
More informationBARCODE SCANNER PA-BR-001
BARCODE SCANNER PA-BR-001 Users Menu Book BROTHER INDUSTRIES, LTD. Ver.0 I Editing and publishing notices Brother Industries, Ltd. reserves the right to modify, without notice, materials and specifications
More informationWhat it takes to make a new state of the art diagnostics platform for Point of Care use.
What it takes to make a new state of the art diagnostics platform for Point of Care use. 31.10.2006 Axis-Shield plc 450 employees Turnover 58 million Profit before tax 1,9 million R&D spend 7,4 million
More informationAriol. Clinical IHC and FISH Breast Marker Analysis Quality. Efficiency. Confidence.
Ariol Clinical IHC and FISH Breast Marker Analysis Quality. Efficiency. Confidence. 3 Behind every breast slide in your laboratory is a woman waiting for life changing answers With over 1.25 million women
More informationUsing the Commonwealth Bank EFTPOS terminal with QuickPOS
Q U I C K P O S S U P P L E M E N T Using the Commonwealth Bank EFTPOS terminal with QuickPOS This special supplement shows you how to set up and use QuickPOS with the Commonwealth Bank s EFTPOS terminal.
More informationBioPlex 2200 System. Like no other. The first and only fully-automated, random access, multiplex testing platform. Bio-Rad Laboratories
Bio-Rad Laboratories BIOPLEX 2200 SYSTEM BioPlex 2200 System Like no other. The first and only fully-automated, random access, multiplex testing platform Bio-Rad Laboratories BIOPLEX 2200 SYSTEM Fully
More informationMobile Hand Held Devices
Using the Mobile Hand Held Device in Connected and Disconnected Modes When using the Connected Mode all changes in erportal are real time. If using the Disconnected Mode and before removing the device
More informationScanning Devices Label Counting Table Operations Manual
Scanning Devices Label Counting Table Operations Manual This document describes the functions performed by counting table components and suggests procedures for setting up and operating the counting table.
More informationLUC UOU Examples Talk Track
LUC UOU Examples Talk Track (Slide 1): Welcome to the AHRMM Learning UDI Community. This presentation is intended to provide more information on potential use cases for the Unit of Use (also known as the
More informationDAC / Fanuc Robotic Screw Insertion Work Cell
10949 Crystal Falls Parkway Leander, TX 78641 Phone: (512) 528-9501 Fax: (512) 528-9429 DAC / Fanuc Robotic Screw Insertion Work Cell Project Overview: This machine is designed for any customer that requires
More informationINSTRUCTIONS FOR USE
VITROS Chemistry Products Slides 847 9396 847 8034 Rx ONLY Intended Use For in vitro diagnostic use only. VITROS Slides quantitatively measure creatine kinase () activity in serum and plasma using VITROS
More informationSelectra ProM. Delivering trouble free results laboratories can trust. CLINICAL SYSTEMS About ELITechGroup Clinical Systems...
About ELITechGroup Clinical Systems... SPECIFICATIONS THROUGHPUT Typically 180 tests / hour; Up to 266 ISE tests / hour. Measuring temperature 37 C, REAGENT Refrigerated reagent rotor controlled with Peltier
More informationStreamline workflow for higher productivity and patient throughput. DirectView. Classic CR System
Streamline workflow for higher productivity and patient throughput. DirectView Classic CR System DirectView Classic CR System Improve your workflow and boost productivity with compact, single-cassette
More informationTosoh Result Integrity Multi-Tasking Efficiency
AUTOMATED ENZYME IMMUNOASSAY ANALYZER Tosoh Result Integrity Multi-Tasking Efficiency TOSOH BIOSCIENCE www.tosohbioscience.us Four Configurations Provide Expansion Capabilities Features: First result in
More informationcobas 8100 automated workflow series 3-D intelligence in lab automation
3-D intelligence in lab automation Personalized Lab Automation Maximizing Testing Efficiency and Medical Value Hospital network Commercial laboratories Independent hospitals At Roche, laboratory automated
More informationMaxwell RSC Blood DNA Kit
TECHNICAL MANUAL Maxwell RSC Blood DNA Kit Instructions for Use of Product AS1400 Caution: Handle cartridges with care; seal edges may be sharp. Revised 1/15 TM419 Maxwell RSC Blood DNA Kit All technical
More informationMD20xx Laser Barcode Scanner
MD20xx Laser Barcode Scanner User Manual Version: MD20xx_UM_EN_V1.1.3 Notice Ensure that the optional DC adapter works at +5V, especially for the RS-232 interface cable. Make sure you carefully read the
More informationCompleting the performance picture.
Completing the performance picture. AU5800 Clinical Chemistry Systems Blood Banking Centrifugation Chemistry Flow Cytometry Hematology Hemostasis Immunoassay Information Systems Lab Automation Molecular
More informationVERSANT kpcr Molecular System
VERSANT kpcr Molecular System Application Guide Addendum Running Dynamic Assay Protocols Using the VERSANT kpcr Molecular System SMN: 10814065 Rev. C Copyrights No part of this work covered by the copyrights
More informationPSC Cover 8/27/99 1:45 PM Page 1. Informatics, Inc th Street Plano, TX LASER PROGRAMMING GUIDE
PSC 31301 Cover 8/27/99 1:45 PM Page 1 Laser Programming Guide Laser Programming Guide Informatics, Inc. 1400 10th Street Plano, TX 75074 www.waspbarcode.com LASER PROGRAMMING GUIDE Informatics, Inc. 1400
More informationHandheld Laser Scanner
Handheld Laser Scanner PROGRAMMING GUIDE PSC Scanning, Inc. 959 Terry Street Eugene, Oregon 97402-9120 Telephone: (541) 683-5700 Toll Free: (800) 547-2507 Telefax: (541) 686-1702 www.pscnet.com PSC and
More informationcobas 8100 automated workflow series 3-D intelligence in lab automation
3-D intelligence in lab automation Personalized Lab Automation Maximizing Testing Efficiency and Medical Value Hospital network At Roche, laboratory automated solutions deliver the quality and reliability
More informationSmart Check System Model 888 Smart Sorter Model 773 and Model 775 Sort Bin Model 777
Smart Check System Model 888 Smart Sorter Model 773 and Model 775 Sort Bin Model 777 Staff Guide 3M Library Systems 3M Center, Building 225-4N-14 St. Paul, MN 55144 1000 1 800 328 0067 www.3m.com/library
More informationmeddispense Automated Dispensing Series Medication and Inventory Management that s easy-to-use, easy-to-afford, not easy to be without.
meddispense Automated Dispensing Series Medication and Inventory Management that s easy-to-use, easy-to-afford, not easy to be without. TouchPoint Medical s automated dispensing systems streamline inventory
More informationHamilton Microlab STAR Reference Guide
Hamilton Microlab STAR Reference Guide Revision History 1 Introduction 2 ML STAR Components 3 System Software 7 Safety Precautions 8 Perform A Run 10 Deck Layout and Icon Legend 12 Maintenance 14 Troubleshooting
More informationMEDICATION AND INVENTORY MANAGEMENT
MEDICATION AND INVENTORY MANAGEMENT THE COMPANY The Global Medics Group is a young dynamic company servicing the Australasian market with unique and niche products to the four Key market segments - Aged
More informationHuman DNA Alu Amplification by Polymerase Chain Reaction (PCR)* Laboratory Procedure
Human DNA Alu Amplification by Polymerase Chain Reaction (PCR)* Laboratory Procedure *Polymerase Chain Reaction is covered by patents owned by Hoffmann-La Roche, Inc. This experiment was adapted from Laboratory
More informationListing with FBA Tutorial Part 2: FBA Shipment
Listing with FBA Tutorial Part 2: FBA Shipment Contents Chapter 1: Upload items as FBA to Amazon...1 Chapter 2: Create FBA Shipment Work Flow...1 Chapter 3: DYMO Printer...7 Chapter 1: Upload items as
More informationBest Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31)
Best Selection for Your Business Electronic Pricing Scale User s Manual (Model: TP-31) CATALOG 1. Foreword... 2 1.1. Introductions... 2 1.2. Main functions and features... 2 1.3. Specification... 2 1.4.
More informationTable of Contents.
Quick Start Guide Table of Contents Equipment Setup and Break-Down 1 2 Processing a Sale 3 Payment Types 3 Tax Change 3 Scanning Items 4 Price Checks 4 Voids/Returns 4 Reprints 4 Gift Certificates 5 All
More informationSpectraLink 8400 Series Wireless Telephone Barcode Administration Guide
SpectraLink 8400 Series Wireless Telephone Barcode Administration Guide September 2012 1725-36973-001 Rev. A SpectraLink 8400 Series Barcode Administration Guide Trademark Information POLYCOM, the Polycom
More informationcobas p 501/701 post-analytical units Automated storage and retrieval for maximum efficiency and safety
cobas p 501/701 post-analytical units Automated storage and retrieval for maximum efficiency and safety Personalized Lab Automation Maximizing Testing Efficiency and Medical Value At Roche, laboratory
More informationcobas p 501/701 post-analytical units Automated storage and retrieval for maximum efficiency and safety
cobas p 501/701 post-analytical units Automated storage and retrieval for maximum efficiency and safety Personalized Lab Automation Maximizing Testing Efficiency and Medical Value Hospital network Commercial
More informationAttestation Sample. This document shows you what to expect when you attest for 2014 using the 2011 Edition of Chiro QuickCharts.
Attestation Sample dbc DB Consultants, Inc. This document shows you what to expect when you attest for 2014 using the 2011 Edition of Chiro QuickCharts. The data contained herein is fictitious. Do NOT
More informationCISPro Live User Instructions
1 CISPro Live User Instructions University of Pennsylvania Contents I. LOG-IN INSTRUCTIONS:... 2 II. OVERVIEW OF ENTERING YOUR INVENTORY... 3 III.SEARCHING FOR A MATERIAL... 4 IV.SELECTING A MATERIAL...
More informationAU680 Chemistry Analyzer In-Lab Training Manual
AU680 Chemistry Analyzer In-Lab Training Manual AU680 In-Lab Training Manual Page 1 of 152 AU680 In-Lab Training Manual Page 2 of 152 AU680 Chemistry Analyzer WARNINGS AND PRECAUTIONS Read all product
More informationIntegrated Library Systems: An introduction. Ontario Library Service-North First Nation Technology Summit. Doris Rankin March 20, 2013
Integrated Library Systems: An introduction Ontario Library Service-North First Nation Technology Summit Doris Rankin March 20, 2013 What is an ILS? specialized suite of modules manages the day-to-day
More informationSIMMS. Barcoding Manual. Table of Contents. Generating and Printing Barcodes. Items. Barcodes Module. Generating and Printing Barcodes.
201-31234 Wheel Avenue, Abbotsford, BC V2T 6G9 Tel: 604-504-7936 Fax: 604-504-7976 Website: www.kcsi.ca Email: sales@kcsi.ca SIMMS Inventory Management System Barcoding Manual Table of Contents Barcodes
More informationExpert workflow management cobas p 612 pre-analytical system. Professional management of laboratory processes
Expert workflow management cobas p 612 pre-analytical system Professional management of laboratory processes Expert workflow management Concept Professional management of processes in diagnostic laboratories
More informationSahara Pro Advanced colorant performance
Sahara Pro Advanced colorant performance Sahara Pro The next generation of colorant performance. The state-of-the-art Sahara Pro delivers everything you need to increase productivity and save time and
More informationMini Scanner New Purchase Order... 3
Mini Scanner New Purchase Order Mini Scanner New Purchase Order... 3 Mini Scanner Dialog Box... 4 Create Purchase Order... 5 Acknowledgement... 6 Acknowledging a Purchase Order... 6 Creating a Service
More informationQC 1D Series : QC510X, 511X QC620X, 621X QC630X, 631X QC710X, 711X QC720X, 721X QC7506, User Guide
QC 1D Series : QC510X, 511X QC620X, 621X QC630X, 631X QC710X, 711X QC720X, 721X QC7506, 7516 User Guide Revision History Version Description Date V1.0.0 Initial release. June 23, 2015 Table of Contents
More informationDigital Slide Sharing and Consultative Strategies and Tactics Pathology Informatics 2011 October 6, 2011
Digital Slide Sharing and Consultative Strategies and Tactics Pathology Informatics 2011 October 6, 2011 Walter H. Henricks, M.D. Cleveland Clinic Digital Slide-based Second Opinion Consult Service Subspecialty
More informationPower Express In-Lab Training Manual Reference Key. Chapter 7 In-Lab Training Competency Exercise
Power Express In-Lab Training Manual Reference Key Chapter 7 In-Lab Training Competency Exercise The competency exercise should be completed by the end of the in-lab training session. All materials supplied
More informationImplementation of Template Driven Clinical Analyses, Plate Manager, and Clinical Protocol Manager to Replace In-House Custom Clinical Systems
Implementation of Template Driven Clinical Analyses, Plate Manager, and Clinical Protocol Manager to Replace In-House Custom Clinical Systems LabWare LIMS v6 Project Francesco DePierro Asc. Director, Research
More informationBN II The power of choice
BN II The power of choice BN II The intelligent system for The BN II, with more than 1500 instruments sold so far, is one of the latest additions to the successful range of BN systems. This third generation
More informationNote: The taller 100 x 13 mm tube is not designed to run on the ACL TOP. Plasma after centrifugation of these tubes must be placed in sample cups.
Created Revised Reviewed Approved Lupus Insensitive aptt on the ACL TOP HEM 4.15.1 7/13/2012 4/11/2013 4/11/2013 4/11/2013 I. PRINCIPLE The activated partial thromboplastin time is a global screening procedure
More informationSUBJECT: System Software Patch Provides Support for Fast SYBR Green Master Mix and RNA-to-C T
User Bulletin Applied Biosystems StepOne and StepOnePlus Real-Time PCR Systems March 2008 SUBJECT: System Software Patch Provides Support for Fast SYBR Green Master Mix and RNA-to-C T In This User Bulletin
More informationI. VersaCall Modules Data Input & Machine Interface Module Machine Interface Modules Receives Inputs Directly from CNC Machine Wired
Caterpillar Torreon Mexico VersaCall Data Input - Capturing OEE Information CNC Machines I. VersaCall Modules Data Input & s Receives Inputs Directly from CNC Machine Wired Linked w/serial Cable Data Input
More informationBLISTER PACK DISPENSING MACHINE
BLISTER PACK DISPENSING MACHINE ABOUT US Founded in 1967 by Sir Graeme Douglas, Douglas Pharmaceuticals Ltd is one of the fastest growing pharmaceutical companies in Oceania. Outstanding customer service
More informationRelative Quantification (Mono-Color) Unknown samples (purified total RNA, mrna or cdna or genomic DNA)
The LightCycler 480 System Short Guide Topic: Purpose: Assay Principle: Detection Format: Result: Relative Quantification (Mono-Color) Describes how to set up and perform mono-color Relative Quantification
More informationQuick Guide. CSN950 MultiHead Dimensioner _v2d_MAN_QG_CSN950MH_EN
Quick Guide CSN950 MultiHead Dimensioner File: 20160406_v2d_MAN_QG_CSN950MH_EN CSN950 MultiHead Quick Guide Table of Contents 1. Safety Instructions... 2 Safety and General Precautions... 2 2. Specifications
More informationApplied Biosystems QuantStudio 12K Flex Real- Time PCR System: OpenArray Plate
QUICK REFERENCE Applied Biosystems QuantStudio 12K Flex Real- Time PCR System: OpenArray Plate Pub. Part no. 4478673 Rev. A Rev. Date June 2012 In this guide WARNING! GENERAL SAFETY. Using this product
More informationSpectralink PIVOT 8744 Smartphone. Barcode Administration Guide
Spectralink PIVOT 8744 Smartphone Barcode Administration Guide 721-0044-000 Rev: B February 2017 Copyright Notice 2016-2017 Spectralink Corporation All rights reserved. Spectralink TM, the Spectralink
More informationAn Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+
An Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+ LAB ADV COMP 8 From Advanced Chemistry with Vernier, Vernier Software & Technology, 2004 INTRODUCTION A titration, as you recall, is a
More informationQuick Reference Instructions
PROFILE -V Quick Reference Instructions Reader System Before performing the test, refer to the PROFILE -V MEDTOXScan Drugs of Abuse Test System Insert and MEDTOXScan User Manual for complete operating
More informationTissue Microarray Catalog
Tissue Microarray Catalog 2012 2013 The most complete tissue microarray product line you can choose from Manual TMA Kits Semi-Automatic Tissue Arrayer Fully Automated Tissue Microarray Builder 1 EZ-TMA
More informationOnline Ordering System. Order and Inventory Management Training Manual v4.2
Online Ordering System Order and Inventory Management Training Manual v4.2 Online Ordering System Logging In to BloodHub: Production/Live environment oneblood.bloodhub.com Validation/Training environment
More informationADAPTIVE BIOTECHNOLOGIES DIAGNOSTIC PORTAL: ACCOUNT LOGIN
ADAPTIVE BIOTECHNOLOGIES DIAGNOSTIC PORTAL: ACCOUNT LOGIN 1. Create an account. To set up your account for our online order entry and reporting system, please go to: https://diagnostics.adaptivebiotech.com/account/login.
More informationXerox Nuvera Xerox Production Stacker Operator Manual
Software Version 11.6 October 2012 702P00782 Xerox Nuvera Xerox Production Stacker Xerox Nuvera 100/120/144/157 EA Production System Xerox Nuvera 100/120/144 MX Production System Xerox Nuvera 200/288/314
More informationBlister Dispensary Machine
Blister Dispensary Machine This is what you have been asking for - a safe, fast, accurate and reliable dispensing machine that is easy to run and feels like a hard-working member of your team. Alpaca makes
More informationExpert workflow management cobas p 512 pre-analytical system Professional management of laboratory processes
Expert workflow management cobas p 512 pre-analytical system Professional management of laboratory processes COBAS, COBAS INTEGRA, COBAS E, COBAS P, MODULAR PRE-ANALYTICS EVO, ELECSYS and LIFE NEEDS ANSWERS
More informationCMC Challenges for cell therapy manufacturing
CMC Challenges for cell therapy manufacturing ISCT Annual Meeting May 2010 Ian Fitzpatrick The Premise In the absence of absolute product characterization.. Successful clinical trials demonstrate that:
More informationThe Advantages of Automatic Quality Control (AQC) for Blood Gas Testing QC
Siemens Healthcare Diagnostics, the leading clinical diagnostics company, is committed to providing clinicians with the vital information they need for the accurate diagnosis, treatment and monitoring
More informationINNOVANCE DTI Assay Delivering the Reliability Your Lab Needs to Confidently Test for Dabigatran
Eva-Maria Landmann Marketing Manager Hemostasis INNOVANCE DTI Assay Delivering the Reliability Your Lab Needs to Confidently Test for Dabigatran INNOVANCE DTI Assay* Introduction Clinical Information Dabigatran
More informationNox DoD. User Guide. Version 3.0.x. Nox for DoD User Guide! Page 1
Nox DoD User Guide Version 3.0.x Nox for DoD User Guide! Page 1 Contents Overview! 3 Shipment Manager -- Nox Administrator Roles! 3 Floor Manager / Packaging -- Nox User Roles! 4 Helpful Notes! 5 Creating
More informationGE Healthcare Life Sciences. Biacore T200. Instrument Handbook
GE Healthcare Life Sciences Biacore T200 Instrument Handbook Contents 1 Introduction 1.1 Biacore T200 system... 5 1.2 The Instrument Handbook... 6 1.3 Associated documentation... 6 2 Important user information
More informationApplied Biosystems 7900HT Fast Real-Time PCR System. Performing Fast Gene Quantitation with 384-Well Plates DRAFT
User Bulletin Applied Biosystems 7900HT Fast Real-Time PCR System October 3, 2005 SUBJECT: Performing Fast Gene Quantitation with 384-Well Plates In This User Bulletin System Overview System Requirements
More informationRevolutionary Tabletop Automation. Prescription Validation, Counting and Filling System
TM 9420 Revolutionary Tabletop Automation Prescription Validation, Counting and Filling System TM 9420 The next generation pharmacy automation system Eyecon continues to become the preferred choice of
More informationInstructions for Use for In Vitro Diagnostic Use
Instructions for Use for In Vitro Diagnostic Use P/N B14255E February 2015 EC REP Beckman Coulter Ireland, Inc. Mervue Business Park, Mervue, Galway, Ireland (353 91 774068) Printed in U.S.A. 2015 Beckman
More informationAutomating Traceability for the Meat and Seafood Industries
Automating Traceability for the Meat and Seafood Industries What s all the buzz about Traceability for Meat and Seafood? Regulations from the FDA, NOAA, Homeland Security in the US, international regulations,
More informationCARESTREAM DIRECTVIEW Max CR System
CARESTREAM DIRECTVIEW Max CR System Boost CR productivity with a workflow leader. Maximize throughput, productivity, and patient satisfaction with the CARESTREAM DIRECTVIEW Max CR System. A next generation
More informationBarkeep Instructions for the Escali SmartConnect Scale
Barkeep Instructions for the Escali SmartConnect Scale These instructions are for users of the Escali SmartConnect Kitchen Scale purchased from barkeepapp.com. Users of any other digital scales and/or
More informationLaboratory Management for Clinical and Research NGS Labs
Laboratory Management for Clinical and Research NGS Labs Introduction Few can argue that Next Generation Sequencing is having a major impact on genomics research. The progress in this field exceeds even
More informationPaper Store. Version
Paper Store Version 1.1 2000-06-30 3Tec automation GmbH - Wilhelmstr. 8 - D-32602 Vlotho Tel. +49 5733-960009 - Fax +49 5733 960007 E-Mail info@3tec.de - Sparkasse Bielefeld - BLZ 480 501 61 - Konto-Nr.
More informationRobinson Manufacturing Company, Inc. College Concepts, LLC. Vendor Shipment Management System (VSMS)
Robinson Manufacturing Company, Inc. College Concepts, LLC. Vendor Shipment Management System (VSMS) http://lansa.robinsonmfg.com/vsms User Documentation 03-10-2017 1 Contents Introduction Key Features...
More informationHR3290 CS Marlin. Wireless 2D Barcode Scanner User Guide
HR3290 CS Marlin Wireless 2D Barcode Scanner User Guide Disclaimer 2016-2017 Fujian Newland Auto-ID Tech. Co., Ltd. All rights reserved. Please read through the manual carefully before using the product
More informationThermo Scientific Sorvall BIOS 16 Centrifuge. performance simplified. at every turn
Thermo Scientific Sorvall BIOS 16 Centrifuge performance simplified at every turn Thermo Scientific Sorvall BIOS 16 Centrifuge Performance simplified at every turn Introducing the NEW! Thermo Scientific
More informationSRI. Your competitive edge. Omega. World-class label finishing
Omega SRI Your competitive edge World-class label finishing Omega SRI The latest generation of label finishing Ergonomic design Whilst designing the SRI we put special emphasis on user friendliness, including
More informationELISA STAR Standard Solutions
ELISA STAR Standard Solutions Fully automated ELISA processor Bench Top Compact solution for automated ELISA processing The new ELISA STAR bench top instrument is a fully automated ELISA processor which
More informationOPTIDOSE Traceable Polymer System OPTIDOSE Test Kits
OPTIDOSE Traceable Polymer System OPTIDOSE Test Kits Ever since polymers have been used as dispersants in cooling water treatment systems, there has been a need for a method of testing the polymer concentration.
More informationPFBH room 341 Steris Autoclave Operation
University of California San Diego Dept. of Bioengineering Standard Operating Procedure SOP000026 V0.5 PFBH room 341 Steris Autoclave Operation Issuing Office: Dept. of Bioengineering, JSOE Responsible
More informationINTRODUCING OUR SELF SERVICE SOLUTION FOR DOCUMENT SCANNING & DEPOSIT
INTRODUCING OUR SELF SERVICE SOLUTION FOR DOCUMENT SCANNING & DEPOSIT SELF SERVICE DOCUMENT SCANNING & DEPOSIT Meet our revolutionary solution for self service document submission, scanning & deposit,
More informationMobile Inventory Management
Mobile Inventory Management 1 Table of Contents Mobile Inventory Management... 2 Overview... 3 Features... 4 Intuitive Design... 5 Functions... 6 Business Applications... 7 2 Mobile Inventory Management
More informationTiger Controls Engineering, Installation and Assembly
Tiger Controls Engineering, Installation and Assembly Lab Equipment, Work Stations and Shelving for NC Division of Air Quality Control 2008: Tiger Controls can install lab equipment. This order was for
More information