Thermal Insulation of Buildings (IIF)

Size: px
Start display at page:

Download "Thermal Insulation of Buildings (IIF)"

Transcription

1 Thermal Insulation of Buildings (IIF)

2 MODERN SOCIETY EXPECTANCE OFFICE / RESIDENCE

3 ENVIRONMENT HEAT IMPACT ON BUILDING High ambient affects roof continuously with heat ingress High ambient heats up at least 2 walls facing afternoon sun Low ambient conditions always affects walls with cold ingress

4 EFFECT OF HEAT FROM ENVIRONMENT Keeps on increasing inside house temperature Inside temperature crosses outside (4-10 PM) Higher humidity & ambient conditions Unbearable oppressive climate inside Situation improves only after mid night Higher Air Conditioning Loads and increased running time of the Compressors Higher Energy cost EFFECT OF COLD Transmission of Cold during evening or during chilly wind environment Inside of house colder than outside

5 WHAT THERMAL INSULATION CAN DO Creates an envelope outside the building Stop heat / cold ingress from outside Maintains at least 8-9 degrees temp. difference Maintains controlled temp. for longer periods Human comfort High Quality of Life 5

6

7 HEAT TRANSFER FROM HIGHER TO LOWER TEMPERATURE

8 WHAT THERMAL INSULATION CAN DO TYPICAL HOT SUMMER ROOF SITUATION DAYTIME AMBIENT TEMP. (DEG.C) WORKING FLOOR TEMP. (DEG.C) INSULATED ROOF WORKING FLOOR TEMP. (DEG.C) 10 AM 12PM PM -2PM PM-4PM PM-6PM Normal building with 150mm RCC, Water Proofed, Brick Wall Insulation : 50-75mm

9 THERMAL INSULATION OF BUILDINGS Buildings world over consume more than 40% of the Energy Generated followed by Industry(32%) and Transportation (28%) So any attempt to save Building Energy Consumption is beneficial 9

10 THERMAL INSULATION OF BUILDINGS Building Energy Consumption Air conditioning - 57 % Lighting - 22% Ventilation Fans - 16% Miscellaneous - 5% Thermal Insulation improves Air conditioning effectivity.

11 THERMAL INSULATION OF BUILDINGS This major energy demand in a building is due to Building Envelope which contributes to 60-75% of heat gain / loss. Insulation of Building envelope (Roof & Wall) is a key factor to reduce heat gain / loss and reduce energy cost. Leed India & GRIHA advocate Building Envelope Insulation. Insulation of Roof & Wall reduces air conditioning load, electricity consumption. High Quality of Life

12 Insulation materials as per ECBC context Fibrous Rigid Flexible* Rockwool Insulation Rigid polyurethane foam Nitrile Rubber Glass wool Insulation Rigid Poly Isocyanurate foam Cross linked polyethylene Sprayed rigid polyurethane foam Expanded polyethylene Extruded polystyrene foam Expanded polystyrene foam Phenolic foam *Flexible Insulation: They are non-fibrous rubber or thermoplastic material in nature which are easily shaped to any design or geometry and predominantly used in HVAC.

13 Scope of Insulation in Buildings Roof Insulation Underdeck Overdeck Wall Insulation External Internal

14 Scope of Insulation in Buildings Source : ECBC User guide

15 Source : ECBC User guide Climate Zone Map of India

16 Climate Zone Description Summer Midday ( High) Mean Temperature ( C) Summe Winter Winter r Night Midday Night (Low) (High) (Low) Diurnal Variation Mean Relative Humidit y Annual Precipitatio n Sky Condition s Places Hot and Dry High Temperature, Low Humidity and rainfall, Intense solar radiation and a generally clear sky, Hot winds during the day and cool winds 40 to 45 at night, Sandy or 20 to 30 5 to 25 0 to to 20 rocky ground with little vegetation, Low underground water table and few sources of surface water Very Low< Low mm/yr 40% Rajasthan, Cloudless Gujarat, skies with Western high solar Madha radiation, Pradesh, causing Central glare. Maharashtr a etc.

17 Climate Zone Description Summer Midday ( High) Mean Temperature ( C) Summe Winter Winter r Night Midday Night (Low) (High) (Low) Diurnal Variation Mean Relative Humidit y Annual Precipitatio n Sky Condition s Places Warm and Humid Temperature is moderately high during day and night, Very high humidity and rainfall, diffused solar radiation if cloud cover is high and intense if 30 to 35 sky is clear, clam to 25 to to to 25 5 to 8 very high winds from prevailing wind directions, abundant vegetation, provision for drainage of water is required. High 70 to 90% High > 1200 mm/yr Overcast (cloud cover ranging between 40 and 80%) causing unpleasan t glare. Kerala, Tamilnadu, Coastal Parts of Orrisa and Andhra pradesh.

18 Climate Zone Temperate Cold (Sunny / Cloudy) Description Summer Midday ( High) Mean Temperature ( C) Summe Winter Winter r Night Midday Night (Low) (High) (Low) Diurnal Variation Moderate Temperature, Moderate humidity and rainfall, Solar Radiation same throughout the year and sky is generally clear, 30 to to to to 18 8 o 13 High winds during summer depending on topography, hilly or high plateau region with abundant vegetation. Summer Temperature and very low in winter, Low humidity in cold/sunny high humidity in cold /cloudy, High solar 17 to 24/20 4 to 11/17 ( -7) to 8 / radiation in cold/sunny and to 30 to 21 4 to 8 low in cold/cloudy, cold winds in winter, very little vegetation in cold/sunny and abundant vegetation in cold/cloudy. ( -14) to 25 to 25/5 0/ (-3) to to 15 4 Mean Relative Humidity High 60 to 85% Low: 10-50%/ High 70-80% Annual Precipitatio n High > 1000 mm/tr Low: < 200mm/yr/ Moderate 1000mm/yr Sky Condition s Mainly clear,occasi onally overcast with dense low clouds insmmer Clear with cloud cover< 50%/ Overcast for most of the year. Places Bangalore, Goa and parts of the Deccan Jammu and Kashmir, Ladakh, Himachal Pradesh, Uttranchal, Sikkam, Arunachal Pradesh

19 Climate Zone Composite Summer Description Midday ( High) This applies when 6 months or more do not fall within any of the above categories, High temperature in summer and cold in winter, Low humidity in summer and high in monsoon, High direct solar radiation in all seasons except monsoon high diffused radiation, Occasional hazy Hot Winds in summer, cold winds in winter and strong wind in monsoons, variable landscape and seasonal vegetation. Mean Temperature ( C) Summe Winter Winter r Night Midday Night (Low) (High) (Low) Diurnal Variation 32 to to to 25 4 to to 22 Mean Relative Humidit y Variable Dry periods = 20-50% Wet Periods = 50-95% Annual Precipitatio n Variable mm/yr during monson reaching 250mm in the wettest month. Sky Condition s Variable Overcast and dull in the monsoon. Places Uttar Pradesh, Haryana, Punjab, Bihar, Jharkhand, Chattisgarh, madhya Pradesh etc,

20 City Climate Zone City Climate Zone Ahmedabad Hot & Dry Kota Hot & Dry Allahabad Composite Kurnool warm& Humid Amritsar Composite Lucknow Composite Aurangabad Hot & Dry Madras warm& Humid Bangalore Temperate Manglore warm& Humid Barmer Hot & Dry Mumbai warm& Humid Belgaum Warm & Humid Nagpur Composite Bhagalpur Warm & Humid Nellore warm& Humid Bhopal Composite New Delhi Composite Bhubaneshwar Warm & Humid Panjim warm& Humid Bikaner Hot & Dry Patna Composite Calcutta Warm & Humid Pune warm& Humid Chitradurga Warm & Humid Raipur Composite Dehradun Composite Rajkot Composite

21 City Climate Zone City Climate Zone Dibrugarh Warm & Humid Ramgundam warm& Humid Gauhati Cold Ranchi Composite Gorakhpur Composite Ratnagiri warm& Humid Gwalior Composite Raxaul warm& Humid Hissar Composite Saharanpur Composite Hyderabad Composite Shillong warm& Humid Imphal Warm & Humid Sholapur Hot & Dry Indore Composite SunderNagar cold Jabalpur Composite Surat Hot & Dry Jagdelpur Warm & Humid Tezpur warm& Humid Jaipur Composite Tirucchirapali warm& Humid Jaisalmer Hot & Dry Trivandrum warm& Humid Jamnagar Warm & Humid Tuticorin warm& Humid Jodhpur Hot & Dry Veraval warm& Humid Jorhat warm& Humid Vishakhapatnam warm& Humid

22 ROOF ASSEMBLY

23 WALL ASSEMBLY

24 BUILDING INSULATION 1. OVERDECK ROOF INSULATION a. Rigid board slab insulation 1. Roof slab should be totally dried and free from all protrusions and depressions and should have proper sloped for free flow of water (1:100). 2. Providing suitable waterproofing over the Sloping screed 3. Providing and laying specified thickness of RIGID FOAM INSULATION SLAB/BOARD of minimum 32-40±2Kg/m3 density.(the Rigid foam Insulation slab/board can be fixed with suitable adhesive like Hot Bitumen or CPRX compound as OPTIONAL) 4. Providing and laying min. 150 gms Geo Textile membrane or 400g polythene sheet over the fixed INSULATION Slab/BOARD, for the protection and as separation layer. 5. Providing and laying over the Polythene sheet/geo-textile membrane in slope gradient min.40mm thick PCC(1:2:4)in chequered 2.5mtr x 2.5mtr panels, reinforced with welded mesh of 75mm x 75mm x1.5mm embedded in between. 6. Sealing all joints between panels with polymerized mastic. 7. Final finish as per specs or engineer in-charge.

25 BUILDING INSULATION

26 BUILDING INSULATION 1. OVERDECK ROOF INSULATION b. Sprayed Rigid Insulation 1. Roof slab should be totally dried and free from all protrusions and depressions and should have proper sloped for free flow of water (1:100). 2. Cleaning the surface properly with wire brushes manually. 3. Providing and applying a coat of Polyurethane primer at entire roof 6-8 Sqm/Ltr. 4. Providing and applying desired thickness of closed cell sprayed rigid PUF insulation foam of 42±2Kg/m3 density conforming to IS Pt.III with Graco/Gusmer machine. to form a monolithic jointless treatment overdeck insulation of desired density of insulation. The sprayed foam adheres instantly to the roof surface and form a composite system. 5. Providing and laying min.120 gsm Geo Textile membrane or 400g polythene sheet over the layed Sprayed foam insulation, for protection and as separation layer. 6. Providing and laying in slope gradient min.40mm thick PCC(1:2:4)in chequered 2.5mtr x2.5mtr panels, reinforced with welded mesh of 75mm x 75mm x1.5mm embedded in between over the Polythene sheet/geo-textile membrane. 7. Sealing all joints between panels with polymerized mastic. 8. Providing suitable waterproofing treatment. 9. Final top finish as per specs or Engineer in-charge.

27 BUILDING INSULATION

28 BUILDING INSULATION UNDERDECK ROOF INSULATION a) Fibrous Insulation 1. Clean the surface thoroughly with wire brush to free it from dust and chippings. 2. Providing and fixing M.S. cleats of suitable to the ceiling at 1mtr x 1/2mtr. C/C with help of dash fasteners. 3. Providing & fixing DESIRED THICKNESS of FIBROUS INSULATION of minimum Kg / m3 density encased in 200g polythene sheet or one side laminated with Al.foil. 4. All joints to be sealed with adhesive tape/aluminium tape and held tightly in position with the help of criss cross GI lacing wire and further installing the same in 24 G x 3/4 hexagonal wire netting. 5. The joints of the wire netting shall be butted and stitched with GI lacing wire. 6. Final finish as per specs or engineer in charge

29 BUILDING INSULATION ROOF UNDERDECK INSULATION WITH FIBROUS INSULATION

30 BUILDING INSULATION UNDERDECK ROOF INSULATION b) Rigid Insulation 1. Drilling & making holes on R.C.C slab at 1mtr X 0.5mtr C/C size panels. 2. Entire R.C.C surface shall be thoroughly cleaned of all dust, dirt and loose particles by wire brushing. 3. Providing and applying a coat of bituminous primer to the bare R.C.C. ceiling and allow it to dry 4. Providing and Applying cold adhesive to the underside of R.C.C. ceiling as well as to one side of surface & sides of each RIGID INSULATION SLAB/BOARD of density minimum 32-36±2Kg/m3 and press it in position & holding it with the help of screws and washers back to the RIGID INSULATION SLAB/BOARD and press it in position with the help of screws and washers inserted inside the rawl plugs. 5. Butt the joints will together symmetrically and joints sealed with 75mm wide aluminum tape. 6. Providing and fixing chicken wire mesh 24G x 3/4 to the GI screw and tightening the same with lacing wire. 7. Final finish as per specification or engineer-in-charge.

31 BUILDING INSULATION

32 BUILDING INSULATION CAVITY WALL INSULATION a) Spray in-situ Insulation 1. Providing hole with drilling machine on the inner wall at 100mm distance from the edges and thereafter at every approx. 600mm c/c in stagger form starting from bottom to top. 2. Providing and filling through these hole with in-situ pouring of closed cell POLYURETHANE FOAM (CFC FREE) IN THE CAVITY WITH GUSMER/GRACO MACHINE CONFORMING TO IS: 13205, DENSITY OF FOAM SHALL BE 40±2KG/M3.The foam adheres instantly to the wall surface on both sides and has a free rise filling the gap/cavity. 3. The pouring/ in-situ Lloydfoam polyurethane foam insulation would start from the bottom and proceeding up. 4. Finally the hole will be plugged with cement mortar or as per specs

33 BUILDING INSULATION

34 BUILDING INSULATION CAVITY WALL INSULATION b) Fibrous Insulation 1. Providing and fixing, DESIRED THICKNESS of FIBROUS INSULATION of minimum 32-96Kg/m3 density encased/wrapped in polythene sheet/bag of 200 gauge, to the wall in staggered form using fasteners one each at corners 100mm away from edges and one at Centre. 2. Providing and holding the fibrous insulation in position with criss cross lacing wire secured with the earlier fixed fasteners. 3. Finally finishing it with another Brick wall duly plastered and finish smooth.

35 BUILDING INSULATION

36 BUILDING INSULATION CAVITY WALL INSULATION c) Rigid Insulation 1. Providing a coat of bitumen or old CPRX compound on inner side of the wall. 2. Providing and fixing, DESIRED THICKNESS of RIGID INSULATION of minimum 32-40Kg/m3 density to the wall in staggered form using fasteners one each at corners 100mm away from edges and one at Centre. 3. Finally finishing it with another Brick wall duly plastered and finish smooth.

37 BUILDING INSULATION

38 BUILDING INSULATION EXTERNAL WALL INSULATION a) Fibrous Insulation Dry stone cladding/spandrel 1. Providing and fixing DESIRED THICKNESS of FIBRIOUS INSULATION of minimum 32-96Kg/m3 density encased/wrapped in polythene sheet/bag of 200G or one side laminated with Al.foil in the existing wall with the help of fasteners provided at one each at the corner 100mm away from the edge and one at center. 2. Providing and holding the fibrous insulation in position with criss cross Gl lacing wire secured with the earlier fixed fastener. 3. Insulation is can be sandwiched between wall & dry stone cladding or Aluminium cladding etc as per specs or engineer-in-charge.

39 BUILDING INSULATION

40 BUILDING INSULATION EXTERNAL WALL INSULATION b) Rigid Insulation 1. Providing a coat of bitumen or old CPRX compound on to the existing smooth wall. 2. Providing and fixing, DESIRED THICKNESS of RIGID INSULATION of minimum 32-36±2Kg/m3 density to the wall in staggered form using fasteners one each at corners 100mm away from edges and one at Centre. 3. Insulation is can be sandwiched between wall & dry stone cladding or Aluminium cladding etc. as per specs or engineer in charge.

41 BUILDING INSULATION

42 BUILDING INSULATION EXTERNAL WALL INSULATION c) Rigid Insulation 1. Providing and patch applying polymerized cementations based adhesive plaster to the back of the RIGID INSULATION of minimum 32-36±2Kg/m3 density & sticking the same to the existing plastered /smooth brick walls and holding it with insulation fasteners one each at corner. 2. Providing and applying cementations base coat of 1-2 mm over the RIGID INSULATION 3. Providing & fixing glass fiber mesh as reinforcement over the base coat followed by polymerized cementations based top coat plaster of 1-2 mm. 4. The top coat can be finally finished with any paint of choice (As per specs).

43 BUILDING INSULATION External Wall Thermal Insulation System

44 BUILDING INSULATION EXTERNAL WALL INSULATION d) Spray Cast in Situ 1. Providing and applying directly SPRAY INSULATION on the clean wall having minimum 40±2Kg/m3 density in multiple passes to achieve the specified thickness. 2. Providing and applying cementations base coat over the sprayed RIGID INSULATION 3. Providing & fixing glass fiber mesh as reinforcement over the base coat followed by polymerized cementations based top coat plaster of 1-2 mm. 4. The top coat can be finally finished with any paint of choice (As per specs)

45 BUILDING INSULATION EXTERNAL WALL INSULATION WITH PU SPRAY

46 BUILDING INSULATION INTERNAL WALL INSULATION Fibrous Insulation 1. Providing and fixing suitable wall GI channel of suitable size and thickness to the brick / RCC walls with dash fasteners. 2. Providing and fixing FIBROUS INSULATION of minimum 32-96Kg/m3 between the channels with the help of fasteners and holding it in place with GI lacing wire. 3. Providing and fixing desired thickness Gypsum/Cement fibre/ply board with drywall screws at 300 mm c/c. ensuring proper jointing and finished to have a flush look which includes filling and finishing the tapered or square edges of boards with jointing compound and joint paper tape. 4. Finally providing two coats of top coat as a primer over the entire surface which can be finished with paint or wall papers or any other texture finish.

47 BUILDING INSULATION INTERNAL WALL INSULATION WITH FIBROUS INSULATION

48 BUILDING INSULATION PARTITION WALL INSULATION Fibrous Insulation 1. Providing internal wall partition framework of GI channel of suitable size and thickness. 2. Providing and fixing FIBROUS INSULATION of minimum 32-96Kg/m3 between the partition framework and holding it in place with GI lacing wire. 3. Providing and fixing on both side Gypsum/Cement fiber/ply board in staggered form with drywall screws at 300 mm c/c. ensuring proper jointing and finished to have a flush look which includes filling and finishing the tapered or square edges of boards with jointing compound and joint paper tape. 4. Finally providing two coats of top coat as a primer over the entire surface which can be finished with paint or wall papers or any other texture finish.

49 BUILDING INSULATION PARTITION WALL INSULATION WITH FIBROUS INSULATION

50 INSULATION OF BUILDINGS Typical Industry Practice Part of civil contract Last item in building construction Usually no approved list of manufacturers & applicator or turnkey Insulation usually not considered a specialized activity Sometimes material purchased and applied by civil masons Not properly stored at site leading to damages Petty contractors does the insulation job, specs. not followed. Job given to water proofing contractors.

51 INSULATION OF BUILDINGS Typical Industry Practice Last minute order finalization Payment issues Financial pressure of civil contractor budget constraint Time pressure to availability and completion Time pressure leads to specs. compromise Work quantity reduced or even short closed contract. Financial loss to insulation vendor Growth of insulation sector hardly any

52 INSULATION OF BUILDINGS Remedial Measures / Corrections Required Insulation to be made mandatory preferably, highlighting benefits Contracts to include approved vendor list Contractors to mention name of vendor while bidding Sufficient time to be provided for job execution Client / authority to ensure no reduction in scope quantity. If contractor do not perform client /authority to get job done directly. Sample testing mandatory from authorized labs. Municipality clearance only after completion of insulation work. We would like to understand International practice.

53

Thermal Insulation of Buildings

Thermal Insulation of Buildings Thermal Insulation of Buildings Profile Lloyd Insulations have been providing turn-key contracting services, to Indian industry for more than 58 years. As a pioneer & market leader for specialized construction

More information

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1 FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING -HR. -HR. APPLICATION THICKNESS PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table /8" WET FILM (/6"

More information

INTERPLANT STANDARD - STEEL INDUSTRY CODE OF PRACTICE FOR THERMAL. Based on IS 7240:1981 (Superseded by IS 14164:2008)

INTERPLANT STANDARD - STEEL INDUSTRY CODE OF PRACTICE FOR THERMAL. Based on IS 7240:1981 (Superseded by IS 14164:2008) INTERPLANT STANDARD - STEEL INDUSTRY IPSS CODE OF PRACTICE FOR THERMAL INSULATION OF COLD SERVICES Based on IS 7240:1981 (Superseded by IS 14164:2008) IPSS:1-06-031-17 (Second Revision) Formerly : IPSS:1-06-031-02

More information

BBA 001 Documents included under the scope of BBA s ISO UKAS accreditation

BBA 001 Documents included under the scope of BBA s ISO UKAS accreditation BBA 001 Documents included under the scope of BBA s ISO 17065 UKAS accreditation Product Standard Building Systems and Kits BBA Technical Specification 001 Ceiling Products BBA Technical Specification

More information

TECHNICAL SPECIFICATION FOR VARIOUS WATERPROOFING TREATMENT

TECHNICAL SPECIFICATION FOR VARIOUS WATERPROOFING TREATMENT TECHNICAL SPECIFICATION FOR VARIOUS WATERPROOFING TREATMENT Detailing Treatment of Movement Joints (Expansion/Contraction/Sliding joints) A. POLYSULPHIDE SEALANT WORK 1. Removing all dust, dirt etc. from

More information

1. Section 04300: Concrete Masonry Units

1. Section 04300: Concrete Masonry Units SECTION 072000 BOARD INSULATION PART 1 GENERAL 1.1 DESCRIPTION A. To be read with Division 1 General Requirements, Conditions of Contract and all associated drawings. B. Work of this section, as indicated

More information

Envelope Optimization

Envelope Optimization Envelope Optimization Approach to Sustainability NBC Chapter 11: section 8 Mili Majumdar Team Ms Mili Majumdar (Convener) Shri Karan Grover Shri Rajan Venkateswaran Rajan Rawal Nimish Patel Editorial help

More information

Annexure A Request to MoEF&CC for issuing Certified Compliance Report

Annexure A Request to MoEF&CC for issuing Certified Compliance Report Expansion of Mahagun Mywoods (Group Housing) by M/s Mahagun India Pvt. Ltd. Annexure A Request to MoEF&CC for issuing Certified Compliance Report PROJECT PROPONENT: M/S MAHAGUN REAL ESTATE PVT. LTD. ENVIRONMENT

More information

About Insulation & R Value - cmhc.ca

About Insulation & R Value - cmhc.ca About Insulation & R Value - cmhc.ca Insulating Your House While previous generations may have been content to live in drafty houses, most people now want comfortable warm houses. A healthy house today

More information

SealArm Tape TPE. Building & Joint Sealants T E C H N I C A L D A T A S H E E T. Uses. Features and Benefits

SealArm Tape TPE. Building & Joint Sealants T E C H N I C A L D A T A S H E E T. Uses. Features and Benefits Product Description is a high performance Joint Tape system for expansion, it can be used for connection joints as well as for cracks, when fixed to the joint, allows irregular and high movement in more

More information

TUV India Private Ltd. Stainless Steel Profile Wires

TUV India Private Ltd. Stainless Steel Profile Wires TUV India Private Ltd. Stainless Steel Profile Wires Green Power THE ONLY COMPANY using 100% green power for manufacturing stainless steel wires & bars Company Profile Srinagar J A M M U A N D K A S H

More information

ThermaSheet. multi-purpose insulated tile backer panels

ThermaSheet. multi-purpose insulated tile backer panels ThermaSheet multi-purpose insulated tile backer panels A CODE PRODUCT DIMENSIONS RTTBB-06-1200 ThermaSheet Tile Backer Board 6mm 1200mm x 600mm RTTBB-10-1200 ThermaSheet Tile Backer Board 10mm 1200mm x

More information

CONCRETE SCREEDS, INTERIOR FLOORING AND WALL COVERINGS. BME Lepel, Adrienn PhD

CONCRETE SCREEDS, INTERIOR FLOORING AND WALL COVERINGS. BME Lepel, Adrienn PhD CONCRETE SCREEDS, INTERIOR FLOORING AND WALL COVERINGS BME Lepel, Adrienn PhD Claddings Place in the sequence of activities 13Constructing roof LB structure (carpentry) 14Roof tiling (waterproofing, battens,

More information

Thermal Control in Buildings by John Straube (updated )

Thermal Control in Buildings by John Straube (updated ) building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Building Science Digest 011 Thermal Control in Buildings 2006-11-02 by John Straube (updated 2011-12-12)

More information

Sample Specification for the application of De Boer Duo HT 4 Slates/F C180 Two-Layer waterproof warm roofing membrane system to concrete.

Sample Specification for the application of De Boer Duo HT 4 Slates/F C180 Two-Layer waterproof warm roofing membrane system to concrete. Sample Specification for the application of De Boer Duo HT 4 Slates/F C180 Two-Layer waterproof warm roofing membrane system to concrete. This system incorporates a vapour barrier and Equus PIR insulation

More information

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079) WET FILM ± 7.5 ± 5 Design No. CEJ 27 P (HI/JS 20-05) Table. CONCRETE FLOOR ASSEMBLY: Max. two-hour rated concrete floor assembly made from either lightweight or normal weight concrete with a density of 00-50 pcf, with a

More information

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/ General conditions. TYPES OF COVERING 115A SINGLE LAYER REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING warm roofing system

More information

A. The work of this section includes, but is not limited to, the following:

A. The work of this section includes, but is not limited to, the following: SECTION 07 14 00 FLUID APPLIED WATERPROOFING SYSTEM PART 1: GENERAL 1.1 RELATED DOCUMENTS A. All of the Contract Documents, including General and Supplementary Conditions and Division 01 General Requirements,

More information

2006 Building Science Press All rights of reproduction in any form reserved.

2006 Building Science Press All rights of reproduction in any form reserved. building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Building Science Digest 011 Thermal Control in Buildings 2006-11-07 by John Straube Abstract: Providing

More information

Thermal Control Layers: Insulation Materials and Systems

Thermal Control Layers: Insulation Materials and Systems Thermal Control Layers: Insulation Materials and Systems All materials and layers in a building assembly have some resistance to heat flow. However, materials with an R-value of about 2/inch or more (k-value

More information

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces. Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces. BRANZ Appraised No. 678 Ref: P3200 Rev 1 February 2016 Page 1 of 5 1.0 PREAMBLE:

More information

roofing ROOFING Design of the base ROOFING DETAILS

roofing ROOFING Design of the base ROOFING DETAILS DETAILS The general arrangement details and the principles to be followed at skirtings, upstands, abutments, verges, gutters and expansion joints are as details illustrated. SELECTION PARAMETERS It is

More information

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Gypsum board screw attached to wood framing and furring members, joint treatment, and accessories. 2. Installation of

More information

MARMOX CONSTRUCTION BOARDS

MARMOX CONSTRUCTION BOARDS Introduction MARMOX CONSTRUCTION BOARDS Marmox Construction Boards provide a quick cost effective solution tile backer with thermal insulating properties. These innovative construction boards are an ideal

More information

Specifications for Insulation Board wall and ceiling applications

Specifications for Insulation Board wall and ceiling applications Specifications for Insulation Board wall and ceiling applications Product Ref: Marmox Multiboard 600mm wide, 1250/2500mm long. 10, 12.5, 20, 30, 40, 50, 60mm thick. Also known as Marmox Board- Pro and

More information

Approaching towards innnovation. An ISO 9001:2015 Certified company

Approaching towards innnovation. An ISO 9001:2015 Certified company Approaching towards innnovation An ISO 9001:2015 Certified company OVER VIEW Trident Steel Building Solutions is an ISO 9001:2015 certified manufacturer of Pre engineered steel buildings and structural

More information

B. Refer to Section : Air Distribution for lined ductwork requirements.

B. Refer to Section : Air Distribution for lined ductwork requirements. SECTION 230700 MECHANICAL INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

A WARM ROOF CONCEPT INCORPORATING A ROOF GARDEN WITH A TWO LAYER DUO LANDSCAPE WATERPROOFING SYSTEM.

A WARM ROOF CONCEPT INCORPORATING A ROOF GARDEN WITH A TWO LAYER DUO LANDSCAPE WATERPROOFING SYSTEM. A WARM ROOF CONCEPT INCORPORATING A ROOF GARDEN WITH A TWO LAYER DUO LANDSCAPE WATERPROOFING SYSTEM. Site name: City/Town: Page 1 of 5 Prepared for: Attention: Specification number: Equus Rep: Dated: PREAMBLE:

More information

CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES

CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES PART 1: SCOPE CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES 1.1 An Approved Celcore Applicator shall furnish all labor, materials and supervision

More information

Self Adhesive EPDM TRAINING MANUAL

Self Adhesive EPDM TRAINING MANUAL Self Adhesive EPDM TRAINING MANUAL Rubber4Roofs Ltd, Unit 4 Kingswood Close Page 1 of 7 Copyright Rubber4Roofs Ltd GeneralHealth&Safety Extreme care must be exercised when working on ladders, roofs, below

More information

An assessment method for residential buildings in Beirut

An assessment method for residential buildings in Beirut An assessment method for residential buildings in Beirut Aram Yeretzian Prime Design - architects daoui building 7th floor - 63 nakkash st. - beirut 2062 4102 lebanon 961 1 398801 / 02 - primedesign@inco.com.lb

More information

PEKAY T570 RUBBERSEAL

PEKAY T570 RUBBERSEAL PEKAY T570 RUBBERSEAL DESCRIPTION Pekay Rubberseal T570 is a rubber-latex modified anionic bitumen emulsion, which dries to a pliable, flexible, waterproof, black coating. It may be used for a variety

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate Colphene BSW Training and Application Guide Colphene BSW Waterproofing Membrane. 1. Prepare substrate Substrate must be structurally sound. Surface must be free of voids, spalled areas, loose aggregate,

More information

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation Recommended Design Considerations and Guide Specifications For Commercial Building Insulation Date of Issue: October 1, 2004 Recommended Design Considerations and Guide Specifications For Commercial Building

More information

PLATON FOUNDATION WRAP

PLATON FOUNDATION WRAP DRAINAGE SOLUTIONS SINCE 1908 PLATON FOUNDATION WRAP RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS DRY ADVANCED TECHNOLOGY EASY INSTALLATION PROVEN PERFORMANCE ARMTEC.COM

More information

BUILT-UP REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING Two layer, EXCEL/SPOT fully adhered waterproofing system

BUILT-UP REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING Two layer, EXCEL/SPOT fully adhered waterproofing system J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/General conditions. TYPES OF COVERING 110A BUILT-UP REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING Two layer, EXCEL/SPOT

More information

Building Enclosure Concept Design Checklist

Building Enclosure Concept Design Checklist Building Enclosure Concept Design Checklist SUPPORT. Support mechanical loads Sufficient strength and stiffness (from structural engineer) CONTROL. Heat Flow Control (Temperature and Energy) avoid thermal

More information

The insulating panel for energy conscious interior renovation. The product. Safe, noticeably better Proved a million times.

The insulating panel for energy conscious interior renovation. The product. Safe, noticeably better Proved a million times. The product Safe, noticeably better Proved a million times The insulating panel for energy conscious interior renovation. Necessary tools: Tips for saving heating costs The heating cost shock due to the

More information

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6 DECEMBER, 2016 Page 1 of 6 1 GENERAL 1.01 RELATED SECTIONS.1 Section 01 33 00 - Submittal Procedures..2 Section 07 21 16 - Batt and Blanket Insulation..3 Section 07 92 10 - Sealants..4 Section 09 91 00

More information

Division 15 INSULATION Section 15100

Division 15 INSULATION Section 15100 Page 1 of 5 SECTION PAGE PART 1 GENERAL 2 1.1 General 2 1.2 References 2 1.3 Work Included 2 1.4 Related Work 2 1.5 Quality Assurance 3 PART 2 PRODUCTS 3 2.1 Description 3 PART 3 EXECUTION 3 3.1 Workmanship

More information

RENOVATE BUILDING 18-C FTFA SECTION GYPSUM BOARD 05/11

RENOVATE BUILDING 18-C FTFA SECTION GYPSUM BOARD 05/11 SECTION 09 29 00 GYPSUM BOARD 05/11 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text

More information

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

LINEAR UP-DOWN AXEONLED SUSPENDED LED LIGHTING

LINEAR UP-DOWN AXEONLED SUSPENDED LED LIGHTING LINEAR SUSPENDED LED LIGHTING AXEONLED STATE-OF-THE-ART SUSPENDED LINEAR LIGHTING FOR CHANGING TIMES Wider and bigger work areas, open office architecture and innovative ceiling systems have become highly

More information

Kronospan. STANDARD EN type OSB 3; EN : class D-s2, d0; EN A1: FORMALDEHYDE CLASS EN EN ISO

Kronospan. STANDARD EN type OSB 3; EN : class D-s2, d0; EN A1: FORMALDEHYDE CLASS EN EN ISO Kronospan OSB 3 Superfinish ECO Superfinish is the most progressive OSB type that is currently available. Superfinish is developed and manufactured entirely in compliance with the current demand of ecological

More information

THERMAL MASS CHAPTER 6. Understanding thermal mass. Seasonal effects of thermal mass

THERMAL MASS CHAPTER 6. Understanding thermal mass. Seasonal effects of thermal mass CHAPTER 6 THERMAL MASS mud brick concrete block brick The contents of this chapter explain the effect of thermal mass and provide guidelines for its location and extent. Summer and winter effects of thermal

More information

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance 1 of 6 5/8/2012 4:19 PM TGIK.R9734 Roofing Systems, Uplift Resistance Page Bottom Roofing Systems, Uplift Resistance See General Information for Roofing Systems, Uplift Resistance KELLY CO-2001 INC 325

More information

ITEM 458 WATERPROOFING FOR STRUCTURES

ITEM 458 WATERPROOFING FOR STRUCTURES ITEM 458 WATERPROOFING FOR STRUCTURES 458.1. Description. This Item shall govern for the furnishing and placing of waterproofing on concrete and steel bridge decks of railroad structures and on other structures

More information

STATE BANK OF INDIA-NUAGAON ADB SCHEDULE OF RATES FOR THE FACE LIFTING OF THE BRANCH BUILDING

STATE BANK OF INDIA-NUAGAON ADB SCHEDULE OF RATES FOR THE FACE LIFTING OF THE BRANCH BUILDING STATE BANK OF INDIA-NUAGAON ADB SCHEDULE OF RATES FOR THE FACE LIFTING OF THE BRANCH BUILDING Sl. No. Description of the Works Unit Quantity Rate Amount 1 DISMANTLING WORKS Surface cleaning of roof by

More information

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

MODIFIED BITUMINOUS SHEET AIR / VAPOUR BARRIERS SELF ADHESIVE

MODIFIED BITUMINOUS SHEET AIR / VAPOUR BARRIERS SELF ADHESIVE Page 1 of 8 MODIFIED BITUMINOUS SHEET AIR / VAPOUR BARRIERS SELF ADHESIVE SOPRASEAL STICK 1100 T FOR A COMPLETE DESCRIPTION OF PRODUCTS AND APPLICABLE STANDARDS, PLEASE REFER TO THE TECHNICAL DATA SHEETS

More information

SHELTER FOR COMPOSITE CLIMATE

SHELTER FOR COMPOSITE CLIMATE SHELTER FOR COMPOSITE CLIMATE Nature of the climate Neither consistently hot and dry, nor warm and humid. Characteristics change from season to season. Significant differences in air temperature, humidity,

More information

LightBUILD Lightweight Cellular Insulating Concrete As a choice for New Roof Decks Construction and Reroofing Applications

LightBUILD Lightweight Cellular Insulating Concrete As a choice for New Roof Decks Construction and Reroofing Applications LightBUILD Lightweight Cellular Insulating Concrete As a choice for New Roof Decks Construction and Reroofing Applications The lightweight insulating concrete roof installation system has a long and proud

More information

THERMAL INSULATION SYSTEM

THERMAL INSULATION SYSTEM opuscolo Kibitherm_EN.FH10 27-06-2007 20:14 Pagina 1 Contents KIBITHERM: a certified system...page 5 Why insulate with KIBITHERM...page 6 KIBITHERM performance features...page 7 How to apply KIBITHERM...page

More information

FIRE STATION 55 June 14, 2010

FIRE STATION 55 June 14, 2010 SECTION 15250 MECHANICAL INSULATION PART 1 - GENERAL 1.01 DESCRIPTION A. Work Includes 1. Insulation of Domestic Water Piping. 2. Pipe Insulation of refrigerant piping. 3. Insulation of ductwork. 4. Aluminum

More information

(Text with EEA relevance) (2017/C 10/02)

(Text with EEA relevance) (2017/C 10/02) C 10/2 EN Official Journal of the European Union 13.1.2017 Commission communication in the framework of the implementation of Regulation (EU) No 305/2011 of the European Parliament and of the Council laying

More information

The new high-performance lining for internal and external applications INSIDE OR OUT YOUR CHOICE

The new high-performance lining for internal and external applications INSIDE OR OUT YOUR CHOICE The new high-performance lining for internal and external applications INSIDE OR OUT YOUR CHOICE Introduction Glasroc X is a high performance building board with a gypsum core containing special additives

More information

Flat roofs. Flat roof design. 2.3 Flat Roofs

Flat roofs. Flat roof design. 2.3 Flat Roofs Flat Roofs Flat roof design Condensation Thermal insulation and the flow of heat and water vapour through a construction are inextricably linked. The position of thermal insulation, vapour control layer

More information

SECTION BUILT-UP BITUMINOUS WATERPROOFING

SECTION BUILT-UP BITUMINOUS WATERPROOFING SECTION 07 12 00 BUILT-UP BITUMINOUS WATERPROOFING SPEC WRITER NOTE: Delete any item or paragraph not applicable in the section and renumber the paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION: This section

More information

DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks.

DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks. DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks. DUCTWRAP AND DUCTSLAB ROCKWOOL Ductwrap and Ductslab provide thermal insulation for air conditioning, warm air and

More information

LIGHT ON THEVERGE TIMELESS. SUBTLE. DISCRETE

LIGHT ON THEVERGE TIMELESS. SUBTLE. DISCRETE LIGHT ON THEVERGE VERGELED TIMELESS. SUBTLE. DISCRETE RIGHT LIGHT FOR CHEERFUL SPACES The 'Right Light' has an enlightening touch on the environment. It goes beyond just illumination to create a warm,

More information

Setting holding down bolts Floor screeds Bedding blocks Stone and bricks In contact with potable water Fine moulding.

Setting holding down bolts Floor screeds Bedding blocks Stone and bricks In contact with potable water Fine moulding. PRODUCT SHEET NATCEM 35 Description NATCEM 35 is a fast setting and fast curing mortar with a rapid strength gain that is resistant to chloride penetration, consisting of a blend of NATCEM Potable Water

More information

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 protecting Membranes 90 System Components.

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 protecting Membranes 90 System Components. 84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 protecting Membranes 90 System Components installation/ SYSTEM COMPONENTS INSTALLATION ADVICE LAPPING and JOINTING

More information

RIW SHEETSEAL GR BENEFITS APPLICATIONS APPLIED TO

RIW SHEETSEAL GR BENEFITS APPLICATIONS APPLIED TO CI/SfB TN6 LI4143 August 2017 RIW SHEETSEAL GR is a cold applied, high density polyethylene film bonded to aluminium foil and coated with a bitumen/rubber self adhesive layer with a removable reinforced

More information

Installation Instructions

Installation Instructions Installation Instructions Roof edge trim profile Series TA-4F multi-piece extruded aluminium profile front face height series TA-4F: 150-200 mm with patented 4F brackets height-adjustable, horizontally

More information

STANDARD SPECIFICATIONS. Followings have been covered in this section. The work is to be carried based on the standard specifications:

STANDARD SPECIFICATIONS. Followings have been covered in this section. The work is to be carried based on the standard specifications: STANDARD SPECIFICATIONS APPENDIX -3 Followings have been covered in this section. The work is to be carried based on the standard specifications: 1) Standard Specifications for Cold Insulation 2) Standard

More information

Ductslab and Ductwrap

Ductslab and Ductwrap CONSTRUCTION TYPE: DUCTS AND TANKS Ductslab and Ductwrap For the thermal insulation of ductwork and water storage tanks ROCKWOOL provide thermal insulation for air conditioning, warm air and extract ducts

More information

BTM BT2K 600. Areas of Use

BTM BT2K 600. Areas of Use BTM BT2K 600 Bitumento BT2K 600 is a solvent-free, two-component, elastic, water-based, fiber reinforced, rubber and cement based bitumen waterproofing material. Areas of Use As water and moisture tight

More information

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/General conditions. A comprehensive waterproofing system comprising two reinforced bituminous membranes fully adhered to thermal

More information

ProGUARD Guide Specification

ProGUARD Guide Specification ProGUARD Guide Specification MANUFACTURER Section: 072100 Insulating Sheathing T.Clear Corporation 3255 Symmes Rd. Hamilton, OH 45015 Phone: 800-544-7398 Phone: 513-870-9246 Fax: 513-870-9606 072113 Cementitious

More information

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent. SECTION 092900 - GYPSUM BOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Standard practice for installing cellulose building insulation

Standard practice for installing cellulose building insulation TECHNICAL BULLETIN Standard practice for installing cellulose building insulation Cellulose insulation can be installed in attics, walls, ceilings, floors, and other building assemblies using a variety

More information

Unit 8 Walls & Partition

Unit 8 Walls & Partition Unit 8 Walls & Partition 1 1 Learning Objectives Briefly explain the functions & functional requirements of walls Differentiate and compare between load bearing and non-load bearing walls Briefly describe

More information

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components. 84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes 90 System Components installation/ SYSTEM COMPONENTS INSTALLATION ADVICE LAPPING and JOINTING

More information

Experimental Study to Evaluate the Performance of Iraqi Passive House in Summer Season

Experimental Study to Evaluate the Performance of Iraqi Passive House in Summer Season Journal of Energy and Power Engineering 9 (2015) 386-392 doi: 10.17265/1934-8975/2015.04.008 D DAVID PUBLISHING Experimental Study to Evaluate the Performance of Iraqi Passive House in Summer Season Ghanim

More information

External Thermal Insulation Composite System Insulation below ground level

External Thermal Insulation Composite System Insulation below ground level Insulation below ground level 1. Concrete wall substrate 2. Aluminium starter base profile 3. Terraco Styrofix (adhesive) 4. Mechanical fastener 5. a. Graphite enhanced polystyrene board b. HD polystyrene

More information

10.1 APPLICATION 1 A. HOT PIPING 1 B. ANTI SWEAT PIPING 1 C. COLD PIPING FINISHES 2

10.1 APPLICATION 1 A. HOT PIPING 1 B. ANTI SWEAT PIPING 1 C. COLD PIPING FINISHES 2 SECTION 10: 10.1 APPLICATION 1 A. HOT PIPING 1 B. ANTI SWEAT PIPING 1 C. COLD PIPING 2 10.2 FINISHES 2 10.3 PIPING FORMAT 3 A. PIPE INSULATION 3 B. PIPE INSULATION 3 C. INSULATION ATTACHMENT 3 D. INSULATION

More information

MONOBASE AAC/ SIDER-PLAST THE ULTIMATE EXTERIOR HARD COAT STUCCO SYSTEM FOR AUTOCLAVED AERATED CONCRETE

MONOBASE AAC/ SIDER-PLAST THE ULTIMATE EXTERIOR HARD COAT STUCCO SYSTEM FOR AUTOCLAVED AERATED CONCRETE SIDER-CRETE, INC. 153 Regur Road Hawkinsville, GA 31036 USA Ph: 478.892.9800 www.sider-crete.com MONOBASE AAC/ SIDER-PLAST THE ULTIMATE EXTERIOR HARD COAT STUCCO SYSTEM FOR AUTOCLAVED AERATED CONCRETE

More information

DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks.

DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks. DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks. DUCTWRAP AND DUCTSLAB ROCKWOOL Ductwrap and Ductslab provide thermal insulation for air conditioning, warm air and

More information

A. National Roofing Contractors Association (NRCA) Roofing and Waterproofing Manual

A. National Roofing Contractors Association (NRCA) Roofing and Waterproofing Manual SECTION 07 22 16 - ROOF AND DECK INSULATION Specifier Note: There are numerous types of roof insulation, some which are installed in multiple-layer roof assemblies. Specifier to verify Project requirements

More information

Technical Data Sheet

Technical Data Sheet Technical Data Sheet ProGUARD Concrete Insulated Sheathing Specifications & Installation Table Of Contents Product Description... pg. 1 Basic Use... pg. 1 Exterior Finishes... pg. 1 Standard Sizes... pg.

More information

INSTALLATION GUIDELINES PRECON

INSTALLATION GUIDELINES PRECON This document has been created as an addendum to our PRECON technical data sheet to provide information regarding the application of PRECON waterproofing/vaporproofing membrane when installed up against

More information

SECTION THERMAL INSULATION

SECTION THERMAL INSULATION Pactiv Building Products 2100 RiverEdge Parkway Suite 175 Atlanta, GA 30328 Toll Free: (800) 241-4402 Web Site: www.green-guard.com SECTION 07210 THERMAL INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS

More information

Sheetseal GR RIW. Sheetseal GR

Sheetseal GR RIW. Sheetseal GR CI/SfB Ln2 April 2009 Sheetseal GR is a cold applied, high density polyethylene film bonded to aluminium foil and coated with a bitumen / rubber self adhesive layer with a removable reinforced silicone

More information

SECTION SELF-ADHERING SHEET MEMBRANE WATERPROOFING

SECTION SELF-ADHERING SHEET MEMBRANE WATERPROOFING SECTION 07 13 26 PART 1 - GENERAL 1.1 SUMMARY A. Scope: 1. Apply waterproofing to: a. Exterior of walls below grade: 1) Waterproofing shall include exterior of walls surrounding elevator pits and sumps.

More information

Glasboard Liners. installation details. Installation Guide for Glasbord Fibreglass Reinforced Plastic (FRP) panels

Glasboard Liners. installation details. Installation Guide for Glasbord Fibreglass Reinforced Plastic (FRP) panels Glasboard Liners installation details Installation Guide for Glasbord Fibreglass Reinforced Plastic (FRP) panels PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION These guidelines are provided

More information

Insulation and Technologies

Insulation and Technologies Interior Design Technology Insulation and Technologies By, Mrs. Noshaba Maryam Chapter Six Building insulation refers broadly to any object in a building used as insulation for any purpose. While the majority

More information

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO SECTION 07220 - ROOF INSULATION PART 1 - GENERAL 1.01 DESCRIPTION A. Work included: The Roofing Contractor will provide all polyisocyanurate insulation and high density wood fiber roof insulation (tapered

More information

SECTION THERMAL INSULATION

SECTION THERMAL INSULATION PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 21 13 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

Advanced technologies for enhancing the building envelope. 3M Building and Construction Market

Advanced technologies for enhancing the building envelope. 3M Building and Construction Market Advanced technologies for enhancing the building envelope 3M Building and Construction Market Controlling air is crucial for the health & energy efficiency of buildings Ensuring you have the right air

More information

Thermal Laminate Board.

Thermal Laminate Board. Thermal Laminate Board www.speedlinedrywall.co.uk The Dry Lining and Thermal Insulation Solution The Dry Lining and Thermal Insulation Solution Around a third of all heat lost within un-insulated or poorly

More information

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS - CHANNELED ADHESIVE

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS - CHANNELED ADHESIVE SECTION 07 24 00 EXTERIOR INSULATION AND FINISH SYSTEMS - CHANNELED ADHESIVE PART 1 GENERAL 1.1 SECTION INCLUDES A. Refer to all drawings and other sections of this specification to determine the type

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 071326 - SELF-ADHERING SHEET WATERPROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Specialities, Assuring Clients of Consistently High Standards Within Record Time Frames.

Specialities, Assuring Clients of Consistently High Standards Within Record Time Frames. GENERAL MAINTENANCE ABOUT US: Al ENAS General Maintenance Est. Is A Dynamic and Progressive Organization That Has Grown to Become One of The Busiest Waterproofing Companies in its Field. Al ENAS Has Been

More information

Caparol System PRO Data sheet

Caparol System PRO Data sheet System features Expanded polystyrene insulation Cost effective solution Excellent detailing options Proven technology Wide variety of colours Reliable protection and crack resistance Proven track record

More information

SOPREMA JARDIN Double Layer Torch-on membrane For water proofing roof gardens and planters

SOPREMA JARDIN Double Layer Torch-on membrane For water proofing roof gardens and planters TECHNICAL DATA Technical data may be updated at any time. It is the users responsibility to check data validity by reference to the website or Nuplex Construction Products MANUAL SECTION ISSUE DATE AUTHORISED

More information

WATERPROOFING OF AN ACCESSIBLE FLAT ROOF WITH A POLYURETHANE LIQUID MEMBRANE AND TILING

WATERPROOFING OF AN ACCESSIBLE FLAT ROOF WITH A POLYURETHANE LIQUID MEMBRANE AND TILING WATERPROOFING OF AN ACCESSIBLE FLAT ROOF WITH A POLYURETHANE LIQUID MEMBRANE AND TILING WATERPROOFING OF AN ACCESSIBLE FLAT ROOF WITH A POLYURETHANE LIQUID MEMBRANE AND TILING 4 5 6 7 3 2 1 1. CONCRETE

More information

Eurothane EuroDeck. Product Guide PIR insulation for Warm Flat Roofs.

Eurothane EuroDeck. Product Guide PIR insulation for Warm Flat Roofs. Eurothane EuroDeck Product Guide PIR insulation for Warm Flat Roofs. Introduction The Company. Driven by a culture of innovation, technical competence and flair, Recticel Insulation Products is dedicated

More information

Civil Engineering Construction Chapter 5

Civil Engineering Construction Chapter 5 Civil Engineering Construction Chapter 5 Introduction to Floor Dr Mohamad Syazli Fathi Department of Civil Engineering UTM RAZAK School of Engineering & Advanced Technology UTM International Campus August

More information

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance UL TGIK.R9734 Roofing Syst. Uplift Resistance * www.2001company.com * 1.800.537.7663 * Page 1 of 6 Page 1 of 6 Page Bottom TGIK.R9734 Roofing Systems, Uplift Resistance Roofing Systems, Uplift Resistance

More information