UNDERGROUND CONSTRUCTION MANUAL FIBRE OPTIC CONSTRUCTION

Size: px
Start display at page:

Download "UNDERGROUND CONSTRUCTION MANUAL FIBRE OPTIC CONSTRUCTION"

Transcription

1 UNDERGROUND CONSTRUCTION MANUAL IBRE OPTIC CONSTRUCTION Back to MAIN INDEX Go to SECTION INDEX

2

3

4

5 IBRE OPTIC CABLE UNDERGROUND - CONSTRUCTION CODE OCU36 CABLE CODE OCU2 OCU36 OCU48 CABLE DESCRIPTION = ibre Optic Cable Underground with 2 ibres = ibre Optic Cable Underground with 36 ibres = ibre Optic Cable Underground with 48 ibres I.I. NUMBER A ORIGINAL ISSUE B HARD COPY UNCONTROLLED Ergon Energy Corporation Ltd ABN APPROVED DATE PASSED DRAWN 7/2/05 D. M K. c C.Lindsay UNDERGROUND DISTRIBUTION IBRE OPTIC CONSTRUCTION CONSTRUCTION CODE GUIDE IBRE OPTIC CABLE Dwg ILE: Sh4 B

6

7

8

9 Kerb Kerb Pit Pole Alignment ootpath ootpath Real Property Boundary O/H - O/H JOINTING PIT ON POLE ALIGNMENT UP / O / W / P UP / O / C / P UJ Pit Real Property Boundary U/G TO U/G JOINTING PIT Electricity ootpath Allocation UP / U / U / E UJ Kerb NOTES: ootpath Pit Real Property Boundary ootpath Kerb Electricity ootpath Allocation O/H - O/H JOINTING PIT ON ELECTRICAL ALLOCATION UP / O / W / E UP / O / C / E UJ OUNDATION. Bed the pit in a 00mm min. layer of stabilised sand or stabilised fine crushed rock (20:). Particle size shall not exceed 5mm. 2. Ensure the level of the foundation will leave the top edge of the pit flush with the finished surface after installation. BACKILL. Backfill material shall be a granular material (not clay) suitable for compaction. 2. Material to be compacted using a mechanical rammer. Care to be taken to ensure no distortion to pit. 3. Cable bearers and covers must be installed prior to backfilling. IBRE OPTIC CABLE. A 2 metre length of each cable shall be left coiled in the pit for jointing. 2. Cable left coiled in a pit shall be in a 500mm minimum diameter loop. 3. In a through pit with no cable joints, leave 24 metres of cable coiled in the pit. Pit Real Property Boundary O/H TO U/G JOINTING PIT Electricity ootpath Allocation UP / OU / W / P UP / OU / C / P UP / OU / W / E UP / OU / C / E UJ CONDUIT INSTALLATION. Conduit shall be installed to a depth of cover of 450mm minimum and 550mm maximum from the finished surface level and separated from existing communication conduits by 00mm. Ramp conduit down at pit to inable entry 50 to 00mm from bottom. A ORIGINAL ISSUE B HARD COPY UNCONTROLLED Ergon Energy Corporation Ltd ABN APPROVED DATE PASSED DRAWN 2/5/03 c D. M K. D. Hower UNDERGROUND DISTRIBUTION IBRE OPTIC CABLE CONSTRUCTION PITS AND JOINTS - INSTALLATION DETAILS Dwg ILE: Sh B

10 MATERIAL - PIT CONSTRUCTION ASSY DESCRIPTION Conduit communication 50 dia. (white) Conduit bend communication 90 Pit No. 8 Cable guard 25mm single to conc.pole Cable guard 25mm double to conc. pole Cable guard 25mm to wood pole QTY UP/O UP/O UP/O UP/O UP/OU UP/OU UP/U /W/P /C/P /W/E /C/E /W/E /C/E /U/E MATERIAL - JOINT ENCLOSURE CONSTRUCTION ASSY DESCRIPTION Splicing enclosure 48 fibres Splicing enclosure 36 fibres QTY UJ/36 UJ/48 MATERIAL - METAL CABLE GUARD ASSY DESCRIPTION Guard, Metal (00) to wood pole Guard, metal (00) to concrete pole UP/O UP/O /W/P /C/P UP/O /W/E QTY UP/O /C/E UP/OU /W/E Connector PG 6/50mm Cu main to 6/50mm Cu tap UP/OU /C/E A ORIGINAL ISSUE B HARD COPY UNCONTROLLED DATE APPROVED PASSED Ergon Energy Corporation Ltd DRAWN ABN /5/03 D. M K. c C.Lindsay UNDERGROUND DISTRIBUTION IBRE OPTIC CABLE CONSTRUCTION PITS AND JOINTS - MATERIAL Dwg ILE: Sh 2 B

11 2m Min Refer Note 2 Sheet Conduit Installation Assy Selection 562-, 6, or Joint enclosure Assy or 0 Assy 56-5 OC Compacted Backfill 450mm Min 550mm Max 50 to 00mm 50mm 50 to 00mm Compacted Backfill Joint enclosure Assy or 0 Assy 56-5 Assy Assy Stabilised Sand OC 450mm Min 550mm Max Assy mm Stabilised Sand 50 to 00mm Pit Construction Type UP / OU / W / P UP / OU / C / P UP / O / W / P UP / O / C / P UP / O / W / E UP / O / C / E UP / OU / W / E UP / OU / C / E UP / U / U / E Joint Construction Type UJ A ORIGINAL ISSUE B.08.0 HARD COPY UNCONTROLLED Ergon Energy Corporation Ltd ABN APPROVED DATE PASSED DRAWN 24/8/05 D. M K. c C.Lindsay UNDERGROUND DISTRIBUTION IBRE OPTIC CABLE CONSTRUCTION PITS AND JOINTS Dwg ILE: Sh 3 B

12

13

14 0305 MATERIAL ASSY DESCRIPTION QTY Warning sign A and post U/G fibre optic cable BURIED IBRE OPTIC CABLES IN THIS VICINITY OBTAIN CABLE LOCATION DETAILS LOCATION O SIGNS: Assy Cable warning signs shall be used in areas remote from Electricity ootpath Allocation. e.g. parkland, carparks, easements. Signs shall be located to clearly identify the cable route. Locate a sign at each change of direction and at 00m maximum centres, provided signs are visible, one to the next. Warning signs may be mounted directly on walls where allowable. inished surface line NOTES: 500. Concrete not included in material. Minimum concrete volume = 0.06m 3 Mass concrete footing 2. Concrete shall be grade N To prevent damage to sign when tightening bolts and nuts, compress flanges of grommets to half their normal thickness only. 4. After fixing sign to post, deform thread of bolt to prevent removal of nut by vandals dia UNDERGROUND IBRE OPTIC WARNING SIGNS TYPE A Construction Type UWSP A ORIGINAL ISSUE HARD COPY UNCONTROLLED DATE APPROVED PASSED Ergon Energy Corporation Ltd DRAWN ABN /2/05 D. M K. c C.Lindsay UNDERGROUND DISTRIBUTION IBRE OPTIC CONSTRUCTION UNDERGROUND IBRE OPTIC CABLE WARNING SIGN POST Dwg ILE: Sh

Operational Update. In all cases Ergon Energy assets are to be located on common land within the community title and not within individual lots.

Operational Update. In all cases Ergon Energy assets are to be located on common land within the community title and not within individual lots. Operational Update Community Title Developments Update #1095-25 Nov 2015 Target Audience: ield Crews, Work Group Leaders, Customer Delivery Managers, Line Managers, ield Assessors, Customer Connection

More information

CONSTRUCTION SPECIFICATION FOR GROUNDING

CONSTRUCTION SPECIFICATION FOR GROUNDING ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 609 NOVEMBER 2001 CONSTRUCTION SPECIFICATION FOR GROUNDING TABLE OF CONTENTS 609.01 SCOPE 609.02 REFERENCES 609.03 DEFINITIONS - Not Used 609.04 DESIGN

More information

UNDERGROUND CONSTRUCTION MANUAL PADMOUNTED SUBSTATIONS

UNDERGROUND CONSTRUCTION MANUAL PADMOUNTED SUBSTATIONS UNDERGROUND CONSTRUCTION MANUAL PADMOUNTED SUBSTATIONS Back to MAIN INDEX Go to SECTION INDEX CONSTRUCTION DESCRIPTION DWG CONSTRUCTION DESCRIPTION DWG PM11 Construction code guide - 11kV Padmounted substations

More information

Cable Protection Systems

Cable Protection Systems Cable Protection Systems Installation Guide V.1 2018 GR-WI-601 Page 1 Introduction This guide addresses the acceptable methods and details for the installation of CABLEprotect ducting & troughing systems.

More information

Demarcation Points. Example 1

Demarcation Points. Example 1 Example 1 control of distribution equipment including connection assets, ending at the customer. REVISION 03 14/04/10 Example 2 ROAD The transformer is normally at the property line. If the transformer

More information

Cable Protection Systems

Cable Protection Systems Cable Protection Systems Installation Guide V.1 2018 GR-WI-602 Page 1 Introduction This guide addresses the acceptable methods and details for the installation of ducting & troughing systems. The purpose

More information

Rough-in frame and flush-mount panel installation instructions

Rough-in frame and flush-mount panel installation instructions Welch Allyn, Inc. 3 State Street Road Skaneateles Falls, NY 33 USA Rough-in frame and flush-mount panel installation instructions 726080 DIR 8002869 Ver. A Revised 206- The Welch Allyn In-Floor Scale models

More information

Underground Distribution Construction Manual

Underground Distribution Construction Manual Underground Distribution Construction Manual Section C3 Padmount Transformer Sites Approved by: C Noel ENERGEX Limited 2018 ABN 40 078 849 055 MANUAL 00305 For 200 to 500kVA 11kV433 250V, concrete bored

More information

LIGHTING CONSTRUCTION MANUAL FLOOD LIGHTING

LIGHTING CONSTRUCTION MANUAL FLOOD LIGHTING CONSTRUCTION MNUL LOOD Back to MIN INDEX Go to SECTION INDEX TYPE DESCRIPTION PGE TYPE DESCRIPTION PGE Construction Type Guide - Pedestrian Crossing - Ergon Construction Type Guide - Watchman loodlight

More information

Technical Data Sheet NEC/GRAN/95:01

Technical Data Sheet NEC/GRAN/95:01 Technical Data Sheet NEC/GRAN/95:01 Installation Guidance Notes Granular Surround Note : These guidance notes refer only to the installation of Granular surround underground tanks. These guidance notes

More information

OVERHEAD CONSTRUCTION MANUAL L.V. CONSTRUCTION

OVERHEAD CONSTRUCTION MANUAL L.V. CONSTRUCTION OVERHEAD CONSTRUCTION MANUAL Back to MAIN INDEX Go to SECTION INDEX CONSTRUCTION DWG CONSTRUCTION DWG Construction Code guide - 06/ Pole top LVABC and Open wire Construction Code Guide - 06/2 Normal Bridge

More information

STANDARD DESIGN NOTES 1 / 2

STANDARD DESIGN NOTES 1 / 2 ISIONS STANDARD DESIGN NOTES / 2 N/A ISIONS STANDARD DESIGN NOTES 2 / 2 N/A 2 FENCE AS REQUIRED BY OWNER. SEE DETAIL 8 / DWG. 9 CAP BLOCK LEVEL WEDGE FOR CAP AS REQUIRED FINAL SITE GRADING MATERIAL BY

More information

UNIFORM STANDARD DRAWINGS CLARK COUNTY AREA, NEVADA YEAR 2015 REVISIONS

UNIFORM STANDARD DRAWINGS CLARK COUNTY AREA, NEVADA YEAR 2015 REVISIONS , NEVADA YEAR 2015 REVISIONS SECTION TITLE AND REVISIONS SUMMARY EFFECTIVE DATE 217.S2 "Residential Curb and Gutter, R-Type" - New drawing to accommodate ADA requirements. 223 "Residential Driveway" -

More information

TS 803 DUCTS DUCT INSTALLATION, PROTECTION AND MARKING WITHIN A TRENCH OPEN TRENCH DUCT INSTALLATION PROFILE

TS 803 DUCTS DUCT INSTALLATION, PROTECTION AND MARKING WITHIN A TRENCH OPEN TRENCH DUCT INSTALLATION PROFILE TORONTO TRANSPORTATION March 2012 TS 803 DUCTS TABLE OF CONTENTS 1. DRAWINGS TTD 803.001 TTD 803.010 DUCT INSTALLATION, PROTECTION AND MARKING WITHIN A TRENCH OPEN TRENCH DUCT INSTALLATION PROFILE 2. CONSTRUCTION

More information

General Symbols, Ducts and Cables

General Symbols, Ducts and Cables DIVISION 2000 - ABBREVIATIONS 2009 11 2000.001 0 Abbreviations, General 2009 11 2011.101 0 General Symbols, Ducts and Cables 2009 11 2011.201 0 General Symbols, Maintenance Holes, Junction Boxes, Pads,

More information

General Symbols, Ducts and Cables

General Symbols, Ducts and Cables DIVISION 2000 ABBREVIATIONS 2009 11 2000.001 0 Abbreviations, General 2009 11 2011.101 0 General Symbols, Ducts and Cables 2009 11 2011.201 0 General Symbols, Maintenance Holes, Junction Boxes, Pads, and

More information

General Symbols, Ducts and Cables

General Symbols, Ducts and Cables MUNICIPAL AND COMMON DIVISION 2000 ABBREVIATIONS 2009 11 2000.001 0 Abbreviations, General 2009 11 2011.101 0 General Symbols, Ducts and Cables 2009 11 2011.201 0 General Symbols, Maintenance Holes, Junction

More information

TYPICAL INSTALLATION INSTRUCTIONS

TYPICAL INSTALLATION INSTRUCTIONS TYPICAL INSTALLATION INSTRUCTIONS Environment One Grinder Pump Feature Identification 1. Grinder Pump Basin High density polyethylene (HDPE) 2. Accessway Cover Painted Steel 3. Electrical Quick Disconnect

More information

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11 Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11 Underground Residential Distribution (URD) Index General Discussion... 1-2 Description... 3-7 Drawings (Available

More information

Foundation Specifications for 3.6-/3.7-Meter Earth Station Antennas

Foundation Specifications for 3.6-/3.7-Meter Earth Station Antennas Installation Instructions Foundation Specifications for 3.6-/3.7-Meter Earth Station Antennas Bulletin 37835A Revision E Introduction This document specifies typical foundation characteristics, designs,

More information

30 X 40 POLE BARN 12 HIGH SIDE WALLS 2-12 WIDE X 10 HIGH SECTIONAL GARAGE DOORS OPTIONAL WINDOWS DETAILS INCLUDED

30 X 40 POLE BARN 12 HIGH SIDE WALLS 2-12 WIDE X 10 HIGH SECTIONAL GARAGE DOORS OPTIONAL WINDOWS DETAILS INCLUDED 30 X 40 POLE BARN 12 HIGH SIDE WALLS 2-12 WIDE X 10 HIGH SECTIONAL GARAGE DOORS OPTIONAL WINDOWS DETAILS INCLUDED 3 ENTRY DOOR METAL ROOF METAL SIDING GABLE ROOF, 4/12 PITCH INDEX PAGE DESCRIPTION 1 FRONT

More information

Section 7: Specifications

Section 7: Specifications Section 7: Specifications 29 31 Building Boundary of Clear Area See Note # 1 8' Shrubs 8' Concrete Pad Equipment 8' TRAVELED WAY M Meter Pedestal 8' Curb Protective Vehicle Posts (Bollards) If Required

More information

TS 804 CABLES TABLE OF CONTENTS TRAFFIC SIGNAL EQUIPMENT POLE WIRING DIAGRAM LOCATIONS WITH CENTRE MEDIANS

TS 804 CABLES TABLE OF CONTENTS TRAFFIC SIGNAL EQUIPMENT POLE WIRING DIAGRAM LOCATIONS WITH CENTRE MEDIANS TORONTO TRANSPORTATION January 2012 TS 804 CABLES TABLE OF CONTENTS 1. DRAWINGS TTD 804.001 TTD 804.002 TTD 804.003 TTD 804.005 TTD 804.006 TTD 804.007 TTD 804.010 TTD 804.015 TTD 804.020 TTD 804.025 TTD

More information

Section 2: Underground

Section 2: Underground Section 2: Underground GENERAL INSTALLATION REQUIREMENTS FOR UNDERGROUND FACILITIES Underground electric service and meter location will be established by NHEC upon site visit. In some instances the type,

More information

HITT STREET UNIVERSITY PROJECT #: CP REFER TO CP PLANS FOR ELECTRICAL DUCTBANK IN HITT STREET INSTALL:

HITT STREET UNIVERSITY PROJECT #: CP REFER TO CP PLANS FOR ELECTRICAL DUCTBANK IN HITT STREET INSTALL: N 1133521.33 E 1689742.43 STA: 10+53.07 INSTALL: 2-10" 90 BENDS CONNECT TO MIDDLEBUSH HALL INTERIOR PLANT PLUMBING MIDDLEBUSH HALL HW1 HWS HWR 10+00 FREDRICK APARTMENTS FINE ARTS INSTALL 422 LF 10" HWS

More information

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets. ALLIANT ENERGY CENTER PAVILIONS Project No. 2013 027 SECTION 27 05 28 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

OVERHEAD CONSTRUCTION MANUAL CONSTRUCTION PRACTICES

OVERHEAD CONSTRUCTION MANUAL CONSTRUCTION PRACTICES OVERHEAD CONSTRUCTION MANUAL Back to MAIN INDEX Go to SECTION INDEX CONSTRUCTION DESCRIPTION PAGE CONSTRUCTION DESCRIPTION PAGE Construction code guide - Cables 1120/1 CP Single circuit concrete pole with

More information

UNIVERSITY OF MISSOURI Hydronic Energy Distribution 2016 Q1

UNIVERSITY OF MISSOURI Hydronic Energy Distribution 2016 Q1 GENERAL: The scope of this document is to provide instruction for the installation and testing of chilled water piping installed for the University of Missouri. DESIGN GUIDELINES: 1. Materials 1.1. Pipe

More information

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 616 NOVEMBER 2008 CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT TABLE OF CONTENTS 616.01 SCOPE 616.02 REFERENCES 616.03

More information

Villawood Properties Pty Ltd Lakeview Estate - Stage 2

Villawood Properties Pty Ltd Lakeview Estate - Stage 2 ORIGINAL DRAWINGS (These are the originals only if this text is RED) Pty Ltd Not Yet Approved by Council TATALIA LANE MILGATE LANE INDEX MURRAY RIVER MURRAY RIVER TWENTY FOUR LANE HOLIDAY COTTAGES RICH

More information

WIRING METHODS CHAPTER 38

WIRING METHODS CHAPTER 38 CHAPTER 38 WIRING METHODS SECTION E3801 GENERAL REQUIREMENTS E3801.1 Scope. This chapter covers the wiring methods for services, feeders and branch circuits for electrical power and distribution. E3801.2

More information

ANY SPECIFICATION DRAWINGS OR DATED PRIOR TO SEPTEMBER 2015 WILL NOT BE HONORED.

ANY SPECIFICATION DRAWINGS OR DATED PRIOR TO SEPTEMBER 2015 WILL NOT BE HONORED. November 30, 2015 Dear STEMC Member and Contractors, Over the years, STEMC has made many changes to its member requirements for new services and specifications associated with those requirements. As a

More information

CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION

CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 604 NOVEMBER 2004 CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION TABLE OF CONTENTS 604.01 SCOPE 604.02 REFERENCES 604.03 DEFINITIONS - Not Used

More information

TS 805 POLES TTS CONSTRUCTION SPECIFICATION FOR POLE INSTALLATION TTS MATERIAL SPECIFICATION FOR STEEL POLES BASE MOUNTED

TS 805 POLES TTS CONSTRUCTION SPECIFICATION FOR POLE INSTALLATION TTS MATERIAL SPECIFICATION FOR STEEL POLES BASE MOUNTED TORONTO TRANSPORTATION January 2012 TS 805 POLES TABLE OF CONTENTS 1. DRAWINGS TTD 805.001 POLE HANDHOLE ORIENTATION DETAILS TTD 805.005 WOOD POLE IN EARTH TTD 805.010 BACK GUY MOUNTING DETAILS TTD 805.015

More information

Model AT Modular Linear Anode

Model AT Modular Linear Anode Model AT Modular Linear Anode Typical Applications: Underground and aboveground storage tanks, buried pipelines, marine structures Featuring: Design flexibility - modular design permits multitude of anode

More information

JABIRU AIRCRAFT PTY LTD PROPELLER INSTRUCTION MANUAL

JABIRU AIRCRAFT PTY LTD PROPELLER INSTRUCTION MANUAL JABIRU AIRCRAFT PTY LTD PROPELLER INSTRUCTION MANUAL 1. Approved Installations The following combinations are approved. Airframe Engine Propeller Dia x Pitch Remarks/Limits Jabiru LSA 55/2K KFM 112M 4046092

More information

Please check with your local inspection authority for any additional requirements before installation.

Please check with your local inspection authority for any additional requirements before installation. Specifications for Residential Underground Electric Service Installation This brochure addresses most typical residential underground service installations. Variances for the following specifications must

More information

CONSTRUCTION SPECIFICATION FOR POLE ERECTION

CONSTRUCTION SPECIFICATION FOR POLE ERECTION ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 615 SEPTEMBER 1993 CONSTRUCTION SPECIFICATION FOR POLE ERECTION 615.01 SCOPE 615.02 REFERENCES 615.05 MATERIALS TABLE OF CONTENTS 615.05.01 Concrete.02

More information

Applying for a Kinder Morgan Cochin Canada / UTOPIA Canada Proximity & Crossing Permit. Design and Construction Guidelines

Applying for a Kinder Morgan Cochin Canada / UTOPIA Canada Proximity & Crossing Permit. Design and Construction Guidelines Applying for a Kinder Morgan Cochin Canada / UTOPIA Canada Proximity & Crossing Permit Design and Construction Guidelines A Guide to Applying for a Kinder Morgan Cochin Canada / UTOPIA Canada Proximity

More information

Foundation Specifications

Foundation Specifications Installation Instructions Foundation Specifications for 3.6-/3.7-Meter Earth Station Antennas ulletin 37835A Revision L Introduction This document specifies typical foundation characteristics, designs,

More information

STREET LIGHTING. Springville City Power standard street lights will be installed in accordance with Springville City Power's Line Extension Policy.

STREET LIGHTING. Springville City Power standard street lights will be installed in accordance with Springville City Power's Line Extension Policy. General The following general requirements shall apply to street lights installed in new underground residential subdivisions or developments located within the service area of Springville City Power (within

More information

CONSTRUCTION SPECIFICATION FOR POLE ERECTION

CONSTRUCTION SPECIFICATION FOR POLE ERECTION ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 615 NOVEMBER 2006 CONSTRUCTION SPECIFICATION FOR POLE ERECTION TABLE OF CONTENTS 615.01 SCOPE 615.02 REFERENCES 615.03 DEFINITIONS - Not Used 615.04

More information

SPECIAL SPECIFICATION 6664 Level (3) Communications System

SPECIAL SPECIFICATION 6664 Level (3) Communications System 2004 Specifications CSJ 1200-05-014 SPECIAL SPECIFICATION 6664 Level (3) Communications System 1. Description. A. This Item will govern the installation of all facilities belonging to Level (3) Communications,

More information

Date: 13/04/2015 1:14:38 PM

Date: 13/04/2015 1:14:38 PM Date: 13/04/2015 1:14:38 PM Cad File No: J:\500-Cad-data\Standard_Drawings\Flow Systems\FSI-1000-FS_On-Lot Infrastructure Installation Set Out Details.dwg Date: 25/02/2015 11:18:14 AM Cad File No: J:\500-Cad-data\Standard_Drawings\Flow

More information

Foundation Specifications

Foundation Specifications Installation Instructions Bulletin 237684 Foundation Specifications for 5.6-Meter Ka-Band Earth Station Antennas 1.0 INTRODUCTION 1.1 This document specifies typical foundation characteristics, designs,

More information

SPECIAL SPECIFICATION 6658 Time Warner Communications System

SPECIAL SPECIFICATION 6658 Time Warner Communications System 2004 Specifications CSJ 1200-05-014 1. Description. SPECIAL SPECIFICATION 6658 Time Warner Communications System A. This Item will govern the installation of all facilities belonging to Time Warner Cable

More information

ISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION

ISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION ISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION FIBERGLASS PACKAGE LS SITE PLAN PAGE No. 111 NUMBER: FG-LS-SITE-PLN FIBERGLASS PACKAGE LS PIPING PLAN PAGE No. 112 NUMBER: FG-LS-PIPE-PLN

More information

Telecommunications Infrastructure

Telecommunications Infrastructure Telecommunications Infrastructure Table of Contents Contents 1. INTRODUCTION... 2 2. DUCTING CAPACITY... 3 3. SUB DUCT SIZING... 4 4. DUCTING AND SUB DUCTING CONSTRUCTION AND COLOUR... 5 5. BUILDING ENTRANCE:...

More information

SALEM CITY POWER ELECTRICAL REQUIREMENTS & STANDARDS MANUAL

SALEM CITY POWER ELECTRICAL REQUIREMENTS & STANDARDS MANUAL SALEM CITY POWER DEPARTMENT TABLE OF CONTENTS Section 1 General Requirements Purpose...1.1 Codes and Ordinances...1.1 Changes or Conflicts in Requirements and Guidelines...1.1 Application for Service...1.2

More information

Network Access Chamber Systems

Network Access Chamber Systems Network Access Chamber Systems Installation Guide V.1 2018 GR-WI-599 Page 1 Introduction This guide addresses the acceptable methods and details for installation of STAKKAbox TM access pits together with

More information

Foundation Specifications

Foundation Specifications Installation Instructions Bulletin 237684 Foundation Specifications for 5.6-Meter Ka-Band Earth Station Antennas 1.0 INTRODUCTION 1.1 This document specifies typical foundation characteristics, designs,

More information

CONSTRUCTION SPECIFICATION FOR STEEL BEAM GUIDE RAIL AND CABLE GUIDE RAIL

CONSTRUCTION SPECIFICATION FOR STEEL BEAM GUIDE RAIL AND CABLE GUIDE RAIL ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 552 NOVEMBER 2002 CONSTRUCTION SPECIFICATION FOR STEEL BEAM GUIDE RAIL AND CABLE GUIDE RAIL TABLE OF CONTENTS 552.01 SCOPE 552.02 REFERENCES 552.03

More information

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 602 MARCH 1993 CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER 602.01 SCOPE 602.02 REFERENCES 602.05 MATERIALS TABLE OF CONTENTS

More information

SV24. Submittal Special Precautions Specifications Installation. 12½" (31.8 cm) 12½" (31.8 cm) 12" (30.5 cm) 12" (30.5 cm) 12" (30.

SV24. Submittal Special Precautions Specifications Installation. 12½ (31.8 cm) 12½ (31.8 cm) 12 (30.5 cm) 12 (30.5 cm) 12 (30. Wastewater Sampling Port Technical Data Submittal Special Precautions Specifications Installation 16½" (31.8 (41.9 cm) 8" (20.3 cm) -L -O SUBMITTAL STANDARD: 4" plain end inlet/outlet Highway traffic load

More information

Electric Service Handbook

Electric Service Handbook Electric Service Handbook Revised August 2017 Contact Information Telephone (253): Electrical Inspection Office 502-8277 7:30 am - 4:30 pm Electrical Inspectors Area Map on Website 7:30 am - 8:30 am Automated

More information

City of St. Catharines Standard Drawings JULY Revised July 21, 2017 TES-ENG (SH)

City of St. Catharines Standard Drawings JULY Revised July 21, 2017 TES-ENG (SH) City of St. Catharines Standard Drawings JULY 2017 Revised July 21, 2017 TES-ENG (SH) Roads Dwg No. Revision Standard Sidewalk Detail 110-2001 1 Monolithic Curb-Faced Sidewalk for Concrete Road 110-2002

More information

TILT-UP LIFTING PRODUCTS

TILT-UP LIFTING PRODUCTS TILT-UP LIFTING PRODUCTS 37 Super-Lift www.meadowburke.com 877-518-7665 STRONGBACKS When will they be needed? A. If a panel looks like it would fall over when standing up. The strongback acts as a crutch

More information

[Type text] Heber Light & Power. Developers & Excavators. Electrical Service Requirements Manual

[Type text] Heber Light & Power. Developers & Excavators. Electrical Service Requirements Manual [Type text] Heber Light & Power Developers & Excavators Electrical Service Requirements Manual May 2017 E.1.1 - GENERAL REQUIREMENTS PURPOSE This section was prepared to aid developers, contractors, engineers

More information

DIVISION 1100 TRAFFIC

DIVISION 1100 TRAFFIC SECTION 1102 STREET LIGHTING GENERAL INFORMATION The Idaho State Electrical Board has determined that all street lights are to be provided with an external fuse disconnect, in a junction box between the

More information

Entellus 75 NORTH STREET MERRILL SHERIFF CONSTRUCTION. 181 North 200 West, Suite #4. Bountiful, UT Phone

Entellus 75 NORTH STREET MERRILL SHERIFF CONSTRUCTION. 181 North 200 West, Suite #4. Bountiful, UT Phone Entllus DUMPSTER PAD AND REPLACE WITH NEW BETWEEN THESE TWO POINTS SAWCUT ALONG DEMO LINE REMOVE PARKING SPOTS CURB, GUTTER, ASPHALT AND LANDSCAPING, WITHIN HATCHED AREA FOR NEW ADDITION CURB & GUTTER

More information

SPECIAL REPAIRS TO EXTERNAL SANITARY ARRANGMENTS AND STREET LIGHTS IN ESI DISPENSARY I & II CAMPUS AT PERAMBUR

SPECIAL REPAIRS TO EXTERNAL SANITARY ARRANGMENTS AND STREET LIGHTS IN ESI DISPENSARY I & II CAMPUS AT PERAMBUR SPECIAL REPAIRS TO EXTERNAL SANITARY ARRANGMENTS AND STREET LIGHTS IN ESI DISPENSARY I & II CAMPUS AT PERAMBUR FINANCIAL BID Item DSR Item Description Qty Units No No. Total 1.1.1 Excavating trenches of

More information

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF DUCTS

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF DUCTS ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 603 APRIL 2010 CONSTRUCTION SPECIFICATION FOR INSTALLATION OF DUCTS TABLE OF CONTENTS 603.01 SCOPE 603.02 REFERENCES 603.03 DEFINITIONS 603.04 DESIGN

More information

SECTION GROUNDING AND BONDING

SECTION GROUNDING AND BONDING SECTION 16060 PART 1 GENERAL 1.01 DESCRIPTION A. Section includes requirements for an electrical grounding system, including electrodes, grounding rods, connectors, insulators, equipment grounding and

More information

UNDERGROUND DROP CABLE CONDUIT INSTALLATION AND SPECIFICATION GUIDELINES FOR SINGLE DWELLING RESIDENTIAL APPLICATIONS

UNDERGROUND DROP CABLE CONDUIT INSTALLATION AND SPECIFICATION GUIDELINES FOR SINGLE DWELLING RESIDENTIAL APPLICATIONS UNDERGROUND DROP CABLE CONDUIT INSTALLATION AND SPECIFICATION GUIDELINES FOR SINGLE DWELLING RESIDENTIAL APPLICATIONS 1. SPECIFICATIONS This document details the specifications for the installation of

More information

Specifications for Electrical Underground Residential Distribution Systems

Specifications for Electrical Underground Residential Distribution Systems Specifications for Electrical Underground Residential Distribution Systems Specification DDS-2 Revision 13, February 2010 ONCOR ELECTRIC DELIVERY COMPANY SPECIFICATIONS FOR ELECTRICAL UNDERGROUND RESIDENTIAL

More information

PART 7 COMMUNICATIONS, LIGHTING, TRAFFIC CONTROL, POWER

PART 7 COMMUNICATIONS, LIGHTING, TRAFFIC CONTROL, POWER PART 7 COMMUNICATIONS, LIGHTING, TRAFFIC CONTROL, POWER COMMUNICATIONS LIGHTING Street Lighting Plan 710 Riser... 287 730 Collar for street light pole... 289 731 Pull box... 291 732 Trench for street light

More information

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF DUCTS

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF DUCTS ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.PROV 603 NOVEMBER 2017 (Formerly OPSS 603, November 2015) Note: The PROV published in November 2017 replaces OPSS 603 COMMON, November 2015 with no technical

More information

VPL-3300B Commercial Vertical Platform Lift Technical Specifications

VPL-3300B Commercial Vertical Platform Lift Technical Specifications Page 1 of 5 VPL-3300B Commercial Vertical Platform Lift Technical Specifications MODEL NUMBERS: Unenclosed VPL-3300B Series: Models VPL-3353B and VPL-3375B (DC-powered) 3-Gate VPL-3300B Series: Models

More information

VPL-3200B Residential Vertical Platform Lift Technical Specifications

VPL-3200B Residential Vertical Platform Lift Technical Specifications Page 1 of 5 VPL-3200B Residential Vertical Platform Lift Technical Specifications MODEL NUMBER: VPL-3200B Series: Models VPL-3210B, VPL-3212B and VPL-3214B (DC-powered units) U.S. F.D.A. CLASSIFICATION:

More information

Underground Service Requirements and Instructions

Underground Service Requirements and Instructions This packet includes all FKEC underground service requirements, instructions, procedures and drawings. If you are considering underground power service please review this document in its entirety (3 page

More information

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING TOOLS AND STRUCTURES

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING TOOLS AND STRUCTURES CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING TOOLS AND STRUCTURES SPECIFICATION EO-1181 REVISION 6 May 2010 EFFECTIVE DATE June 1, 2010 GENERAL

More information

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service.

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service. CHAPTER3 Clark Public Utilities Commercial Electric Service Handbook Commercial Underground Services Preparing for the installation The following checklist will assist in preparing a project for the installation

More information

Information Bulletin:

Information Bulletin: Equipment Advisory Adv. No. 2015012 R1 Supersedes: Adv. No. 2015012 R0 Issue Date: April 21, 2015 File: 1649.10 Information Bulletin: Backfill Revision Note Revised text since R0 edition is shown with

More information

Specifications for Residential Underground Electric Service Installation

Specifications for Residential Underground Electric Service Installation Specifications for Residential Underground Electric Service Installation This brochure addresses most typical residential underground service installations. Variances for the following specifications must

More information

CW 3620 INSTALLATION OF UNDERGROUND TRAFFIC SIGNAL SERVICES TABLE OF CONTENTS

CW 3620 INSTALLATION OF UNDERGROUND TRAFFIC SIGNAL SERVICES TABLE OF CONTENTS December 2012 CW 3620 INSTALLATION OF UNDERGROUND TRAFFIC SIGNAL SERVICES TABLE OF CONTENTS 1. DESCRIPTION... 1 1.1 General... 1 1.2 Definitions... 1 1.3 Referenced Standard Constructions Specifications...

More information

WATER 6.1 GUIDELINES

WATER 6.1 GUIDELINES 6-1 6.0 WATER 6.1 GUIDELINES The requirements of the Queensland Water Resources Commission Guidelines for Planning and Design of Urban Water Supply Schemes shall be followed in general. The requirements

More information

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 604 NOVEMBER 2008 CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE TABLE OF CONTENTS 604.01 SCOPE 604.02 REFERENCES 604.03 DEFINITIONS - Not Used

More information

CHAPTER 12 HANDHOLES, PULLING VAULTS, AND JUNCTION BOXES

CHAPTER 12 HANDHOLES, PULLING VAULTS, AND JUNCTION BOXES CHAPTER 12 HANDHOLES, PULLING VAULTS, AND JUNCTION BOXES HANDHOLES, PULLING VAULTS, AND JUNCTION BOXES The standards and requirements for handholes, pulling vaults, and junction boxes are presented in

More information

Cable Protection Systems

Cable Protection Systems Cable Protection Systems Installation Guide V.1 2018 GR-WI-603 Page 1 Introduction This guide addresses the acceptable methods and details for installation of CABLEprotect ducting & troughing systems.

More information

4 EXTREME FOUNDATION PANELS

4 EXTREME FOUNDATION PANELS 4 EXTREME FOUNDATION PANELS For House Crawl Space On Concrete Footings 1. The type of soil is a factor in determining foundation construction details such as footing design, backfill, and drainage provisions.

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES PART 1 DESIGN DIRECTIVES 1.1 GENERAL SECTION 02801 MISCELLANEOUS SITE DETAILS A. This section consists of AutoCAD drawings depicting typical landscape details governing the installation of miscellaneous

More information

PERMANENT PAVEMENT REPAIR NO SCALE

PERMANENT PAVEMENT REPAIR NO SCALE SAWCUT EXISTING PAVEMENT 2" BITUMINOUS CONCRETE SURFACE COURSE, CLASS 2 (MIN) CLEAN EDGE PRIOR TO PAVING AND PAINT WITH LIQUID BITUMEN. INSTALL SEALANT OVER JOINT UPON COMPLETION 2" BITUMINOUS CONCRETE

More information

Engineering Specifications February, 2004 Schedule H to Bylaw 7452, Subdivision Bylaw Page 105 ELECTRICAL DETAILS. base. base. base.

Engineering Specifications February, 2004 Schedule H to Bylaw 7452, Subdivision Bylaw Page 105 ELECTRICAL DETAILS. base. base. base. Schedule H to Bylaw 7452, Subdivision Bylaw Page 105 4.3.7 Electrical Details ELECTRICAL DETAILS MMCD Standard Detail Drawing Saanich Supplemental Specification E1.1 Concrete Base Index E1.2 Type A and

More information

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.PROV 602 NOVEMBER 2017 CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS TABLE OF CONTENTS 602.01 SCOPE 602.02 REFERENCES 602.03 DEFINITIONS

More information

Alberta Bridge Inventory STANDARD BRIDGE & CULVERT COMPONENTS. Standard Bridges. Typical Bridge Components. In Alberta there are about 13,300 bridges.

Alberta Bridge Inventory STANDARD BRIDGE & CULVERT COMPONENTS. Standard Bridges. Typical Bridge Components. In Alberta there are about 13,300 bridges. STANDARD BRIDGE & CULVERT COMPONENTS Alberta Bridge Inventory In Alberta there are about 13,300 bridges. Types of bridges in Alberta: Standard bridges 3521 (26%) Bridge size culverts 8348 (63%) Major bridges

More information

ROAD CLOSURE GATE PLAN ESTIMATED QUANTITIES CONCRETE FOOTINGS FOR S. D. DEPT. OF TRANSPORTATION DECEMBER 1996 ELEVATION CABLE TIE DOWN FOOTING

ROAD CLOSURE GATE PLAN ESTIMATED QUANTITIES CONCRETE FOOTINGS FOR S. D. DEPT. OF TRANSPORTATION DECEMBER 1996 ELEVATION CABLE TIE DOWN FOOTING ADMIN. S 1 1 13 199 POST Anchor Bolts (4 Required) 1 Pole Base Plate Footing PLAN POST Chamfer on Footing ESTIMATED QUANTITIES ITEM UNIT QUANTITY Footing & Eyebolt Class M5 Concrete CU.YD. 0.5 The quantity

More information

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs November 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements....................................

More information

香港電燈有限公司 THE HONGKONG ELECTRIC CO., LTD. ************************************

香港電燈有限公司 THE HONGKONG ELECTRIC CO., LTD. ************************************ Page 1 of 7 Revision Date: 08/2010 香港電燈有限公司 THE HONGKONG ELECTRIC CO., LTD. ************************************ GENERAL PRACTICE ON EXECUTION OF EXCAVATION AND CONSTRUCTION WORK NEAR UNDERGROUND ELECTRICITY

More information

TANZANIA BUREAU OF STANDARDS

TANZANIA BUREAU OF STANDARDS EDC3 (5238) P3 DRAFT TANZANIA STANDARD (Draft for comments only) Mini-Grid Systems Part 4: Low voltage (LV) underground distribution network TANZANIA BUREAU OF STANDARDS TBS 2017 First Edition 2017 Table

More information

Tasman Retaining Wall System

Tasman Retaining Wall System Tasman Retaining Wall System The Tasman Retaining Wall System incorporates purpose made corners and capping units to provide classical reconstructed stone retaining walls for any landscape situation. From

More information

HANDHOLES, PULLING VAULTS AND JUNCTION BOXES

HANDHOLES, PULLING VAULTS AND JUNCTION BOXES Handholes and pulling vaults perform several important functions: Provide drainage for the conduit system so that freezing water does not damage the conduit or wires. Provide a location for bending the

More information

SECTION 67 SERVICE CONNECTION SYSTEM

SECTION 67 SERVICE CONNECTION SYSTEM 2019 - SECTION 67 SERVICE CONNECTION SYSTEM 67.1 GENERAL Building service connections for water and sewer shall be installed in accordance with these Specifications and/or approved Detailed Engineering

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Gas meter clearances and service installation requirements

Gas meter clearances and service installation requirements FEBRUARY 2018 Gas meter clearances and service installation requirements CALL PSE S CUSTOMER CONSTRUCTION SERVICES AT 1-888-321-7779 OR VISIT PSE.COM/CUSTOMERCONSTRUCTION FOR MORE INFORMATION. Builder/owner/developer

More information

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 DESCRIPTION SECTION 28 05 26 GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY SPEC WRITER NOTE: Delete // // if not applicable to project. Also delete any other item or paragraph

More information

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.MUNI 616 APRIL 2018 CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT TABLE OF CONTENTS 616.01 SCOPE 616.02 REFERENCES 616.03 DEFINITIONS

More information

SECTION A1 EXCAVATION AND BACKFILL GENERAL

SECTION A1 EXCAVATION AND BACKFILL GENERAL SECTION A1 EXCAVATION AND BACKFILL GENERAL The work under this section shall include all excavation to such width and depth as shown on the drawings, specified herein, or ordered by the Engineer. Such

More information

Specifications for Electrical Underground Distribution Systems from Overhead Transformation, Apartments & Condominiums

Specifications for Electrical Underground Distribution Systems from Overhead Transformation, Apartments & Condominiums Specifications for Electrical Underground Distribution Systems from Overhead Transformation, Apartments & Condominiums Specification DDS-3 OH Revision 10, March 2010 ONCOR ELECTRIC DELIVERY COMPANY SPECIFICATIONS

More information

SDCS-02 CONSTRUCTION STANDARD FOR

SDCS-02 CONSTRUCTION STANDARD FOR الشركة السعودية للكهرباء DATE: November 2016 CONSTRUCTION STANDARD FOR UNDERGROUND DISTRIBUTION NETWORK This specification is property of SEC and subject to change or modification without any notice الشركة

More information

Performance of Mechanically Stabilized Earth walls over compressible soils

Performance of Mechanically Stabilized Earth walls over compressible soils Performance of Mechanically Stabilized Earth walls over compressible soils R.A. Bloomfield, A.F. Soliman and A. Abraham The Reinforced Earth Company, Vienna, Virginia, USA ABSTRACT: Two projects have recently

More information