FOR PRE-INSULATED ALUMINUM DUCTING SYSTEM FOR HVAC INSTALLATIONS

Size: px
Start display at page:

Download "FOR PRE-INSULATED ALUMINUM DUCTING SYSTEM FOR HVAC INSTALLATIONS"

Transcription

1 SUBMITTAL FOR PRE-INSULATED ALUMINUM DUCTING SYSTEM FOR HVAC INSTALLATIONS March 2014

2 PROJECT CONSULTANT ITEM PRE-INSULATED ALUMINUM DUCTING FOR AIR-CONDITIONING DISTRIBUTION MANUFACTURER ALP srl Via Vezze CALCINATE BERGAMO ITALY TEL : FAX : alp@alp.it Website :

3 I N D E X - Introduction - The Product - The Manufacturer - Pre-qualifications 1. Product Description 2. Major Technical Advantages 3. Technical Data Sheets 4. Technical Characteristics and Performances 5. Fabrication Details 6. Installation Details 7. Photo Gallery ALP System Ducts 8. References and Photo Gallery

4 INTRODUCTION This submission is about an innovative, environmental friendly and established technology for PRE-INSULATED ductwork for HVAC installations, fabricated using factory made aluminum / polyurethane sandwich panels and specific accessories as alternative to the ductwork specified in the Project s Technical Specifications. THE PRODUCT The proposed ductwork is fabricated using factory made aluminum / polyurethane sandwich panels and specific accessories. This technology, named ALP SYSTEM, has been developed at the beginning of 80 s and it has been considered a revolutionary innovation in the HVAC field. Fast to fabricate and easy to install, ALP SYSTEM pre-insulated ductwork can be adapted to meet every needs in HVAC installations. ALP SYSTEM pre-insulated ductwork are extremely light weight, about 10 times lighter than steel ducting, offering top performances with very long durability, energy saving, high rated insulation and negligible air leakage, without loosing anything in terms of safety, hygiene and fire resistance. ALP SYSTEM pre-insulated ductwork can be installed either outdoor or indoor providing, when exposed, a fine external finish. With installations in more than 40 countries around the world, in almost all the HVAC sectors, from residential to commercial, from food processing and electronics to pharmaceuticals and hospitals, ALP SYSTEM pre-insulated ductwork are definitively the ideal solutions for any HVAC installation. ALP SYSTEM pre-insulated ductwork comply with the strict national and international standards for these types of products and comply with all the international installation standards, such as ASHRAE, SMACNA, DW, etc.

5 THE MANUFACTURER ALP, established at the beginning of 80 s, is the developer and the manufacturer of ALP SYSTEM, the Aluminium Pre-insulated Ductwork. Over the years, the company has expanded and developed an operational structure that today comprises n. 3 production facilities. ITALY - Headquarters and Production The headquarters and the factory, which cover a surface area of 6500 sq.m., are located in Calcinate-Bergamo, about 40 km east of Milan. The facility includes n. 2 Manufacturing Plants, Warehousing, Sales, Marketing Global Purchasing, AutoCAD Engineering & Design and Training departments. UNITED ARAB EMIRATES - Offices and Production The third manufacturing plant, opened in year 2002, is located at Dubai. The facility includes Warehousing, Sales and Marketing departments. TURKEY - Offices and Production The forth manufacturing plant, opened in year 2010, is located at Sincan Ankara. The facility includes Warehousing, Sales, Marketing and Training departments. ALP is widely represented through qualified engineering and marketing personnel based in defined trade regions all over the globe and acting either as commercial agents, representatives or distributors. ALP is an ISO 9001 and ISO Quality Certified Manufacturer, to ensure a reliable process in meeting the most stringent requirements.

6 PRE - QUALIFICATIONS Numerous projects in more than 40 countries around the world, in various fields, among them: - industrial buildings - food industries - civil buildings - pharma industries - hotels - airports - hospitals - sporting centres - clean rooms - swimming pools (also with salty water) - surgical rooms - theatres Reference list of major worldwide installations (attached to this Submittal) ISO 9001 Quality Certificate for Production ISO 9001 Quality Certificate for Training ISO Quality Certificate for Environmental Management System Conforms to most well known standards (Italy, UK, Germany, France) The product is totally CFC-HCFC-HFC FREE, in line with international environmental norms. Fabrication process is also environmentally friendly and hygienic to worker s health, as there is no fiber dispersion. IMPORTANT The fabrication process of ALP System ducts is also environmentally friendly and hygienic to worker s health, as there is no fibre dispersion.

7 1. Product Description

8 PRODUCT DESCRIPTION ALP System Aluminum Pre-insulated Ductwork Ductwork shall be fabricated using ALP System panels, as follows: Air-conditioned Areas Plant Rooms Exposed to Weather Panel ALP 100RF ALP 200RF ALP 230RF Thickness of panel 21 mm 21 mm 30 mm Thickness of aluminum - inside duct 80 microns 80 microns 80 microns - outside duct 80 microns 200 microns 200 microns Rigidity N mm N mm N mm Finishing of aluminum - inside duct embossed embossed embossed - outside duct embossed embossed embossed All panels shall show embossed ALP logo and the printing of the production date. Ductwork shall be fabricated as per ALP Fabrication Standards, using original ALP materials & accessories as a whole. ALP SYSTEM PANELS General Characteristics Sandwich panels made of a close cell rigid polyurethane foam, thermo-bonded on both sides by aluminum foil. Aluminum foil is lacquered with a 3 g/m protecting epoxy varnish. weatherproof and ultraviolet rays Thermal Insulation Characteristics Thermal insulation characteristics of the panels are the following: - Insulating material : close cell rigid expanded polyurethane foam, CFC-HCFC- HFC FREE - Thermal conductivity: 0,0213 W/mK initial value 0,0226 W/mK - aged value, as per EN Standard - The insulation material is physiologically and chemically inert and insoluble, vermin proof, fungus proof, non metabolizable. - No relevant reduction of insulation, chemical or physical characteristics of the panels shall be measurable when conveying air in the temperature range of 35 C to +110 C.

9 - The vapour barrier is granted by the aluminum foils covering the both faces of the rigid foam. Fire safety The panels shall comply with the following standards: - Class 0 as per British Standards BS 476, Part 6 and Part 7 FABRICATION Ductwork shall be fabricated strictly in accordance with ALP requirements & recommendations, using original ALP materials & accessories as a whole. Wherever possible, the maximum length of the single duct shall be of 4000 mm; this will reduce the possibility of air leakage at the joint and it will reduce the time required for the installation. Wherever necessary, the ductwork shall be reinforced using original ALP internal stiffening system (aluminum stiffening rods + PVC round plates). No relevant modification of insulation, chemical or physical characteristics of the panels to be measurable when conveying air up to the pressure of 2000 Pascal. Wherever necessary, VICAT plastic turning vanes will be installed in large metered elbows. Wherever necessary, inspection doors shall be arranged to allow inspections and cleaning of the ducts. Inspection doors shall be manufactured using the same panels and accessories. The ductwork shall be fabricated by a ductwork fabricator approved by ALP. A valid certificate issued by ALP shall be presented by the ductwork fabricator. INSTALLATION Jointing System - To grant an adequate sealing, ductwork shall be joined by means of original ALP aluminum joint flanges and slide-in channels, with the installation of a plastic foam gasket between the ducts to reduce to minimum the air leakage. Hanging System - Ductwork shall be installed using traditional rods & bars as per ALP SYSTEM specifications or, alternatively, as per the recommendations of the Consultants.

10 2. Major Technical Advantages

11 MAJOR TECHNICAL ADVANTAGES OF ALP SYSTEM DUCTS vs TRADITIONAL SHEET METAL DUCTS ALP SYSTEM allows the fabrication of HVAC ductwork using factory made aluminum / polyurethane sandwich panels and specific accessories. Fast to fabricate and easy to install, ALP SYSTEM pre-insulated ductwork can be adapted to meet every needs in HVAC installations. ALP SYSTEM pre-insulated ductwork are extremely light weight, about 10 times lighter than steel ducting, offering top performances with very long durability, energy saving, high rated insulation and negligible air leakage, without loosing anything in terms of safety, hygiene and fire resistance. ALP SYSTEM pre-insulated ductwork can be installed either outdoor or indoor providing, when exposed, a fine external finish. ALP SYSTEM pre-insulated ductwork can be installed in almost any HVAC sector, from residential to commercial, from food processing and electronics to pharmaceutical industries and hospitals; ALP SYSTEM is definitively the ideal solution for any HVAC installation. ALP SYSTEM pre-insulated ductwork comply with the strict national and international standards for these types of products and comply with all the international installation standards, such as ASHRAE, SMACNA, DW, etc. Compared to the traditional sheet-metal ductwork, ALP System pre-insulated ductwork present many advantages; the major are the following: DUCTWORK Long durability (long life of the installation) The main advantage that has made of ALP System ductwork an innovative and successful product is surely their durability, their long life. Their characteristics of stability and immutability, both physical and dimensional, derive from the unique properties of the insulating foam produced by ALP in combination with the typical properties of the aluminum. ALP System ductwork can grant excellent working performances for more than 20 years. On the contrary, traditional sheet-metal ductwork surely get rusted during the years; indeed, the thin zinc layer that protects the duct against rust gets unavoidably damaged during the fabrication and the installation operations, offering thus a number of starting points to the oxidation process. There is no guarantee at all that sheet-metal ductwork will not get rusted. ALP System can grant it!

12 Best air quality (total absence of rust) The use of aluminum, a well-known non-toxic material with high resistance to corrosion, assures the preservation of the purity of the supplied air. This is the reason why ALP System ductwork can be easily installed in those projects where sheet-metal ductwork is rejected and replaced by Stainless Steel ductwork, i.e. Food Industries, Pharma Industries, Clean Rooms and Hospitals. Lightweight - I ALP System ductwork are extremely light in weight, from 4 up to 10 times lighter than sheet-metal ductwork. Handling and installing ALP System ductwork entails consequently the following advantages: - saving of labour time in fabrication - saving of labour time in installation / erection - saving in transportation - saving in consumption of hangers and supports (thinner and less quantity) - saving in equipment required for high levels installation (no need of heavy equipment) - safer work when installation is done at high levels from ground Lightweight - II (Reduction of loads on structures) Another advantage of ALP System ductwork in relation to its lightness is the considerable reduction of the loads on structures that derives from its use. This characteristic is very important for HVAC installations in those projects, such as pre-engineered steel buildings, tents, etc., where the building structure is light and where the weight of A/C ductwork, usually hanged to the roof structure, is really a critical issue. Best air tightness The special fabrication method of ALP System ductwork grants a totally sealed ductwork; on the contrary, sheet-metal ductwork present longitudinal seams that need to be sealed in order to grant air tightness. Furthermore, the exclusive ALP joint system, carried out by means of patented aluminum profiles and flexible gaskets, grants the installation an excellent air tightness, by reducing to a minimum any possibility of air loss. In case of specific project requirements, especially in laboratories or clean rooms, the ALP System ducts can assure total air tightness thanks to the simple adoption of specific installation procedures. Outdoor application (ductwork already provided with cladding) For installation outdoor, when insulated, metal-sheet ductwork require cladding. ALP System is provided with a built-in cladding granted by the thick aluminum foil covering the insulation foam. This allows the outdoor installation of ALP System ductwork without the need of additional materials and works, then: - saving in materials cost (no cladding is required) - saving in labour cost

13 Resistant to salty atmosphere ALP System is made with aluminum. The use of aluminum, a material with high resistance to corrosion, assures the integrity of the ductwork against the aggressive action of salty atmosphere. This characteristic is very important for those installations close to the sea. Easy selection (just 3 panels to cover any installation requirement) For the fabrication of G.I. ductwork it is necessary to operate a selection of the proper G.I sheet among a number of available sheets with different thicknesses (0,6 or 0,7 or 0,8 or 0,9 or 1,0 or 1,2 mm) also considering the following variables: - size of the duct - operating pressure The high number of possible combinations makes the possibility of mistakes from the Fabricator very high. On the contrary, ALP System can cover any installation requirement with only 3 types of panels for the fabrication of ductwork: - Panel ALP100RF indicated for INDOOR installation Panel thickness: 21 mm Aluminum foil thickness: internal - 80 micron external - 80 micron - Panel ALP200RF indicated for MACHINE ROOM installation Panel thickness: 21 mm Aluminum foil thickness: internal - 80 micron external micron - Panel ALP230RF indicated for OUTDOOR installation Panel thickness: 30 mm Aluminum foil thickness: internal - 80 micron external micron Thanks to this simple diversification, ALP System reduces the possibility of mistakes in fabrication, and the Quality Control, carried out either at the Ductshop or at the Site, becomes extremely simple and fast. Easy to fabricate directly at the site (no need of electric tools) Another great advantage of ALP System is its flexibility. The use of few tools and equipment, which do not require any electric power, for the fabrication of ALP System ductwork gives the Fabricator the possibility to carry out the fabrication of the ductwork directly at the site. This option grants: - more accurate job, thanks to the possibility of immediately verifying the conditions at the site, - faster execution in case some modifications are needed

14 Reduction of transportation costs The possibility of arranging the fabrication of ALP System ductwork directly at the site allows to optimize transportation by conveying flat panels instead of cumbersome fabricated ductwork to the site, granting significant savings in transportation costs. INSULATION In HVAC installations, the insulation of the ductwork is carried out by applying an insulating material outside the ductwork. The most used insulation material in HVAC field is Glasswool. Apart the cost of the material itself, additional works are required to install the insulation outside the ductwork and then to insulate the joint after the installation. On the contrary, in ALP System the insulation is an integral element of the ductwork structure, this is the reason why ALP System is known as the preinsulated ductwork. With this pre-insulated ductwork ALP System has introduced a revolutionary concept in HVAC field. Insulation in ALP System is granted by the polyurethane foam board, expanded with a CFC-HCFC-HFC FREE blowing agent. Talking about insulation the advantages of the ALP System pre-insulated ductwork are the following: Duct already insulated No additional work is required to insulate the duct and to insulate the joints after the installation, then: - reducing labour time in fabrication Best insulation material The insulation value of ALP System panels is definitely better in comparison with the value of any other products traditionally used for the insulation of HVAC ducts. Polyurethane is known to be the best insulating material available in the market. The same insulation value of 50 mm thick glasswool can be easily achieved by about 20 mm of polyurethane foam. Long durability One of the major problems of glasswool is its durability, as the thickness reduces with the passing of time. On the contrary, the rigid polyurethane is extremely stable. The close cells of the rigid polyurethane foam and its particular chemical structure grant stability and insulation performances for a long period of time, i.e. for more than 20 years.

15 Even insulation around the ductwork In ALP System ductwork the insulation turns out to be continuous and steady in all points of the duct, especially on the corners where glasswool is normally squeezed to a minimum thickness, then loosing its insulation properties. Glasswool insulation ALP System Pre-insulated Reduced overall dimensions The small thickness of the ALP System insulation allows the installation of ALP System ductwork directly under the ceiling. This gives the possibility to reduce to a minimum the height of the false ceiling. Excellent moisture resistance The close cell structure of the polyurethane foam grants an excellent resistance to moisture absorption. Furthermore, the thick aluminum foil covering the ALP System panels acts as a vapour barrier. No fiber release (total Indoor Air Quality) Contrary to what happens in glasswool, the polyurethane foam does not release any fiber. The fibers released by the glasswool can contaminate the ambient air, creating health problems to the occupants of the building or damaging/affecting industrial manufacturing processes.

16 3. Technical Data Sheets

17 ALP SYSTEM Aluminum Pre-insulated HVAC Air Ducts Technical Data Sheet ALP SYSTEM Aluminum Pre-insulated ducts, self-supporting, for Heating, Ventilation and Air Conditioning air distribution systems. Advantages Long duration granted by the characteristics of the aluminum foil (absolutely no rust or other type of deteriorations) No fibers release or dispersion Very high thermal insulation Outdoor installation without any additional protection Excellent air tightness Resistant to high pressure of the air (positive and negative) Resistant to salty atmosphere Easy access for maintenance Easy cleaning (water washing, brushing or disinfection) Fabrication ALP SYSTEM air ducts are fabricated using a rigid polyurethane foam board, faced on both side by an aluminum foil. - Panel thickness : 21 mm, 30 mm and 50 mm - Rigid polyurethane foam, closed cells, density 48 kg/m 3, without CFC-HCFC-HFC - Internal facing : Aluminum foil, 80 or 500 micron thickness, treated with 3 g/m² of epoxy varnish as protection against weather agents and UV rays, - External facing : Aluminum foil, 80, 200 or 500 micron thickness, treated with 3 g/m² of epoxy varnish as protection against weather agents and UV rays, Application Realisation of HVAC air distribution systems (Supply, Return, Exhaust, Fresh air) to be installed Indoor and Outdoor, especially in the following projects: - Hospitals and Operating Suites, - Clean Rooms and Pharmaceutical Industry, - Food Industry, - Swimming Pools. Specifications of Use Temperature ( C) Air Velocity (m/sec) Pressure (Pascal) +110 / Fire Rating - British Standard : Class 0 (BS 476 Part 6 & 7) Technical Characteristics Panels Stiffness : Thermal Conductivity : (new panel) (aged panel) EI u > N mm 0,0213 W/(m K) 0,0226 W/(m K) Thermal Resistance : R 0,986 m 2 K/W Water Vapour Transmission : Z 2 hpa)/mg Nominal Pressure* : Positive: Pascal Negative: Pascal (*) Higher Pressures are possible Please contact ALP. Duct Sealing Class Range REF. Typical Application Panel Thickness Aluminum Foil Thickness Pressure (Pascal) Class C ALP100RF Indoor 21 mm 80 m 80 m ALP200RF Machine Rooms 21 mm 200 m 80 m ALP230RF Outdoor 30 mm 200 m 80 m ALP550/500 Heavy Duty 50 mm 0,5 mm 0,5 mm 400 C 1000 B 2000 B Performances reached with a standard fabrication. Better Sealing Class can be reached Please contact ALP. NOTE: All data refers to tests carried out on basic ALP100RF panel

18 Outdoor Installation ALP SYSTEM Aluminum Pre-insulated HVAC Air Ducts Photo Gallery Machine Rooms Indoor Installation Colour Painted Ducts

19 4. Technical Characteristics and Performances

20 TECHNICAL CHARACTERISTICS AND PERFOMANCES - RESUME TABLE - Characteristic Standard Result Mechanical - Panel Stiffness / Rigidity EN N mm - Resistance to high pressure EN Pa in Normal operation Pa in 1 h Over-pressure - Resistance to positive/negative pressure ALP Pa / Pa No breakages or loss of functionality - Air leakage (Positive/Negative Pressure) EN 1507 Class C and B - Air pressure drop inside ductwork Istituto Giordano Negligible - Resistance to high temperature ALP 110 C / 230 F - Resistance to salty atmosphere ISO 9227 No corrosive attack - Sound reduction index EN-ISO R w = 16 db Insulation - Thermal Conductivity EN New panel 0,0213 W/(m K) - Aged 0,0226 W/(m K) 25-year accelerated ageing - Thermal Resistance EN ,986 m 2 K/W - Water vapour transmission EN Resistance Z = Fire Safety - Flammability (British Standards) BS 476 Part 6 & Part 7 Class 0 Health & Environment - Microbial growth EN Resistant to fungine attack - Overall migration (Food Industry) EN and Italy MOH Decree 174/2004 Less than 6,9 mg/dm 2 Copy of the Technical Test Reports and Approvals are available upon request.

21 5. Fabrication Details

22 ALP SYSTEM FABRICATION DETAILS Typical section of ALP System ductwork Aluminum foil (external cladding) Rigid insulation foam Aluminum foil Sealant Note: All internal corners are sealed to avoid air comes in contact with insulating foam

23 ALP SYSTEM FABRICATION DETAILS Corners and Joint Profiles Corners will be installed to grant a perfect square of the ductwork. A) Nylon-glass corners for Standard Joint profile Nylon-glass corners STANDARD Joint profile B) Metal corners for Invisible Joint profile Corners INVISIBLE Joint Profile

24 ALP SYSTEM FABRICATION DETAILS Internal Stiffening System PVC plate Aluminum Rod Cross-fixing device

25 ALP SYSTEM FABRICATION DETAILS Turning Vanes

26 6. Installation Details

27 ALP SYSTEM INSTALLATION DETAILS Jointing System - Standard Standard Joint Flange Plastic Foam Gasket Aluminum Slide-in Channel

28 ALP SYSTEM INSTALLATION DETAILS Jointing System - Invisible Invisible Joint Flange Plastic Foam Gasket Plastic Slide-in Channel Corner Cover

29 ALP SYSTEM INSTALLATION DETAILS Hangers & Supports Supports for Horizontal Ducts DUCT SIZE HANGERS BEARERS SPACING Longer side Drop Rod diam. Angles Channels Max up to mm 25 x 25 x 1,6 40 x 20 x 1, mm 25 x 25 x 1,6 40 x 20 x 1, mm 25 x 25 x 1,6 40 x 20 x 1, mm 25 x 25 x 3,0 40 x 20 x 1, over 3000 Note: all dimensions are in millimetres SPECIAL ANALYSIS REQUIRED Traditional system ALP System self-adhesive duct support

30 7. Photo Gallery ALP System Ducts

31 ALP System Aluminium Pre-insulated HVAC Ducts Photo Gallery

32 ALP System Photo Gallery

33 ALP System Photo Gallery

34 ALP System Photo Gallery

35 ALP System Photo Gallery

36 8. References and Photo Gallery

37 REFERENCES ALP System air ducts have been installed in more than 40 countries around the world and in any possible application, among them: Airports Hotels Commercial Centres Industries Offices High-rise Buildings Hospitals & Operation Suites Pharma Industries Clean Rooms Food Industries Swimming Pools Stadium & Sport Centres A list of projects is available upon request.

38 Italy Reference Photo Gallery GLOBAL ALP System Aluminum Pre-insulated Air Ducts AirportCatania Industry AleniaAeropace HospitalComo ShoppingMallEtnaPolis CentreCommercialCarrefour CathedralSt.Francesco HotelGolfClubHiltonAcaya Industry Fly MilitaryAirportDecimomannu FoodInd.Zanetti AirportNapoli CongressCenterPalarimini BergamoFairground FoodInd.Albertengo OfficeBuildingsTorriGaribaldi

39 France Reference Photo Gallery GLOBAL ALP System Aluminum Pre-insulated Air Ducts AIRBUSSpiritAeroSystem MotorolaAngers BaseAerienneBricy MadeleinBijouSt.YriexLaPerche PX TherapeuticsGrenoble BuffaloGrillNantes MixBuffetRedon LCLRennes MaxiZooNantes UExpressSt.PèreenRetz DOUXPleucadeuc SodeboMontaigu ChateauGrandBarrailSt.Emilion ChateauRougetPomerol ChâteauFonréaudMedoc

40 Ireland Reference Photo Gallery GLOBAL ALP System Aluminum Pre-insulated Air Ducts ConcertHallO 2 ArenaDublin HospitalSt.James sdublin AvivaStadiumDublin DublinConventionCenter DublinGrandCanalTheatre KileenCastleGolfClub Romania CocaColaPloiesti CityParkMallConstanta SwissCapPharmaInd. McDonald srestaurants BCRBankBranches OtopeniIntlAirport ElviraGodeanuTheater ROMTELECOMOffices PrismaCommercialCenterBucharest

41 Poland Reference Photo Gallery GLOBAL ALP System Aluminum Pre-insulated Air Ducts POLROSShoppingMall HYPERNOVASupermarket PTAKShoppingMall BOSCHLodz PKNOrlen POLSATTVStudios CzechRep. ZOFINTheatre MASOPLANAFoodIndustry FARMAKPharmaInd. MOPOSIndustry BRANIKBrewery StirinChateauConferenceCentre Norway BergenBrannStadium TonsbergGildeFoodInd. TromsoSASRadissonHotel

42 Cyprus Reference Photo Gallery GLOBAL ALP System Aluminum Pre-insulated Air Ducts LarnacaInternationalAirport UNILEVERNicosia CyprusBroadcastingTV Germany WeidenClinic Heidelberg ProMinentOffices EisenachHotelTuringenHof OSRAMMunich BMWShowroomEisenach SparkasseWartburgkreis Bulgaria MallofSofia CBASupermarkets Various VolvoCarCenterSofia

43 Slovenia Reference Photo Gallery GLOBAL ALP System Aluminum Pre-insulated Air Ducts PIVKAFoodIndustry GrandHotelMetropole GrandHotelBernardin AvsenikHotel&ConferenceHall HotelZusterna GrandHotelMorjePortoroz

44 Turkey Reference Photo Gallery GLOBAL ALP System Aluminum Pre-insulated Air Ducts HospitalACIBADEMBodrum MostLifeClub Ankara TCDDTurkishStateRailways CocaColaMaksan TuyapExhibitionCentre AKBankVarious OptimumShoppingMallIzmir PlazaHotelIstanbul GalatasarayUniversity VAKKOShowroomVarious McDonald s Various MydonoseShowland TobaccoFactoryIzmir DivanHotelIstanbul Youth&SportMinistry

45 UAE Reference Photo Gallery GLOBAL ALP System Aluminum Pre-insulated Air Ducts MalloftheEmiratesDubai SharjahMegaMall FerrariStoreDubai EmiratesTowerDubai 21 st CenturyTowerDubai AbuDhabiNationalBank MarinaCrownTowerDubai GrosvenorHouseTowerDubai ETISALATTowerDubai LeMeridienHotelFujairah DubaiConventionCentre DubaiKnowledgeVillage

46 Qatar Reference Photo Gallery GLOBAL ALP System Aluminum Pre-insulated Air Ducts GiantStoreDoha AlQassarTower RasLaffanControlRoom Kuwait ChestDiseasHospital MishrefIntlFairground SabahalAhmadUrologyCenter InstituteforJudicial&LegalStudies KuwaitTwinTowers PizzaHutRestaurant

47 Morocco Reference Photo Gallery GLOBAL ALP System Aluminum Pre-insulated Air Ducts OujdaInternationalAirport MoroccoMall Casablanca HotelSofitelCasablanca CaravanseraiHotelMarrakech DecathlonCasablanca CasablancaFacultyofMedicine Algeria DjelfaOphatlmologyClinic OranPiscinePublique NovoNordiskPharmaInd. Libya SHELLLibyaDiversTraining ZuwaraHospital ODACPolyclinicsVarious TawfeekHotel AbuFakhraMosqueBenghazi PrivateVillaTripoli

48 Singapore Reference Photo Gallery GLOBAL ALP System Aluminum Pre-insulated Air Ducts NTUInnovationCentre ShangrilaHotel MarinaSquareShoppingMall Various ALBANIABleuTowers HUNGARY AquaParkZalaegerszeg IRANIsfahanCityCentre KSAJeddahKAUSTUniversity PAKISTAN IslamabadTheCentaurus PAKISTANIslamabadNUST PORTUGALHortaSportCenter SERBIA PharnaInd.HEMOPHARM SLOVENIAM/YSarha

Production Technology

Production Technology Introduction There has been a need to introduce new QUALITY PRODUCTS in the construction & Cold Storage industry in the region for many years. EIP was set up at Dubai Investment Park in the UAE to address

More information

GUIDE SPECIFICATION: DUCT LINER

GUIDE SPECIFICATION: DUCT LINER GUIDE SPECIFICATION: DUCT LINER This specification guide includes thermal & acoustical insulation for ductwork and air handling systems. This section is based on the format recommended by MICA (Midwest

More information

Phenolic Foam (PF) Insulation

Phenolic Foam (PF) Insulation Class O CFC & HCFC Free Phenolic Foam (PF) Insulation The Superior Insulation Foam The Quality Insulation Products for Many Diverse Application Chilled Water Pipe and Duct Insulation Slab Insulation Roof

More information

KINGSPAN KOOLDUCT SYSTEM. Product. Scope. Building Regulations. Appraisal No. 771 [2017]

KINGSPAN KOOLDUCT SYSTEM. Product. Scope. Building Regulations. Appraisal No. 771 [2017] KINGSPAN KOOLDUCT SYSTEM This Appraisal replaces BRANZ Appraisal No 771 (2012) s Technical Assessments of products for building and construction. Product 1.1 The Kingspan KoolDuct System is pre-insulated

More information

Technical Submission Spiralite Pre-insulated Ductwork

Technical Submission Spiralite Pre-insulated Ductwork Technical Submission Spiralite Pre-insulated Ductwork This Spiralite technical submission and performance specification covers air-distribution HVAC ductwork systems and insulation requirements. It is

More information

Knauf Product Brochure. AH-PL-19 May The Knauf KoolDuct. System. High Performance Pre-Insulated Ductwork

Knauf Product Brochure. AH-PL-19 May The Knauf KoolDuct. System. High Performance Pre-Insulated Ductwork Knauf Product Brochure AH-PL-19 May 2007 The Knauf KoolDuct System High Performance Pre-Insulated Ductwork Emphasis is on High Performance With the Knauf KoolDuct System Knauf Insulation presents a revolutionary

More information

Insulated Panels for a Clean World

Insulated Panels for a Clean World Insulated Panels for a Clean World Emirates Industrial Panel (EiP( EiP) Established in Dubai, UAE in 2007 Provides comprehensive insulated panel solutions for industrial and commercial construction market

More information

.1 Thermal insulation for insulated piping and piping accessories affected by construction and new pipe sections as indicated on drawings.

.1 Thermal insulation for insulated piping and piping accessories affected by construction and new pipe sections as indicated on drawings. BID OPPORTUNITY NO. 253-2011 PAGE 1 OF 8 PART 1 GENERAL 1.1 SUMMARY.1 Section Includes: 1.2 REFERENCES.1 Thermal insulation for insulated piping and piping accessories affected by construction and new

More information

HAPRI. About us. What are the environmental benefits of Polyiso insulation?

HAPRI. About us. What are the environmental benefits of Polyiso insulation? INSULATION MATERIALS MANUFACTURING About us HAPRI Insulation Materials Manufacturing is one of the UAE Leading Thermal Insulation Company dealing in Polyurethane/Polyisocyanurate insulation, Pre-Insulated

More information

FLEXIBLE PREINSULATED PIPES

FLEXIBLE PREINSULATED PIPES FLEXIBLE PREINSULATED PIPES Our production site Based in Casalromano, near Mantua, about 100 km from Milan, our plant covering an area of 50,000 square metres [5,000 of which are roofed], we manufacture

More information

1 of 17. PO Box Bellevue Rd, Newark, DE V F

1 of 17. PO Box Bellevue Rd, Newark, DE V F 1 of 17 Raw Material Manufactured from 4 8-foot sheets Fiber-reinforced 1-mil aluminumfaced polyisocyanurate panels 0.032 embossed aluminum Other patterns and stainless steel are available Necessary supplies

More information

ENGINEERED FAÇADE SYSTEM FAÇADE SYSTEMS

ENGINEERED FAÇADE SYSTEM FAÇADE SYSTEMS ENGINEERED FAÇADE SYSTEM FAÇADE SYSTEMS 2 ENGINEERED FAÇADE SYSTEMS The following pages have been designed to make it quick and easy to select and create your complete wall solution. Simply choose our

More information

Insulation TECHNICAL DATA SHEET. Low Energy Low Carbon Buildings. CI/SfB (57.9) In7 (M2) First Issue April 2016

Insulation TECHNICAL DATA SHEET. Low Energy Low Carbon Buildings. CI/SfB (57.9) In7 (M2) First Issue April 2016 Insulation CI/SfB (57.9) In7 (M2) First Issue April 2016 The Kingspan TECHNICAL DATA SHEET System Low Energy Low Carbon Buildings Introduction The Kingspan KoolDuct System is an innovative lightweight

More information

For more information on Kingspan Insulation visit

For more information on Kingspan Insulation visit For further information on the KoolDuct System please telephone the Kingspan Technical Services Department on 01457 861611 (UK) or 042 9795000 (Ireland) The values given against these properties are typical.

More information

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS INTRODUCTION BENCHMARK Wall Liner is an engineered insulated panel system that is ideal for fully supporting single skin metal sheeting such as zinc,

More information

Type II Environmental Declaration according ISO 14021:2001/A1:2011

Type II Environmental Declaration according ISO 14021:2001/A1:2011 Type II Environmental Declaration according ISO 14021:2001/A1:2011 Product: Hunter Douglas Panels Module 200-600mm Product code: 26005 Module 601-900mm Product code: 26025 Module 901-1200mm Product code:

More information

Non-Metallic Ducts made from Insulation Ductboards

Non-Metallic Ducts made from Insulation Ductboards Insulati o n First Issue January 2018 See rear cover for applicable countries Non-Metallic Ducts made from Insulation Ductboards COMPLIANCE WITH EN 13403 Low Energy Low Carbon Buildings Compliance with

More information

Insulated Panels. Insulated Roof Systems. Kingspan X-dek. KS1000 XD Longspan Roofpanel. Systems. Insurer Approved

Insulated Panels. Insulated Roof Systems. Kingspan X-dek. KS1000 XD Longspan Roofpanel. Systems. Insurer Approved Insulated Panels 02 2010 Insulated Roof Systems Kingspan X-dek KS1000 XD Longspan Roofpanel Insurer Approved Systems X dek TM Frame-to-Frame Long Spanning Insulated Roof Deck X dek TM is an insulated roof

More information

Cold Rooms Kide

Cold Rooms Kide COLD ROOMS Cold Rooms 2 Cold under control KIDE it is a business Group manufacturer of cold-rooms, insulation panels, insulated doors, refrigeration units and drying units, offering integral solutions

More information

PRODUCT CATALOGUE PROFLEXR. Thermal Insulation. CFC free HCFC free Zero Ozone Depletion Potential (ODP) Taking care of energy and Environment

PRODUCT CATALOGUE PROFLEXR. Thermal Insulation. CFC free HCFC free Zero Ozone Depletion Potential (ODP) Taking care of energy and Environment PRODUCT CATALOGUE PROFLEXR Thermal Insulation CFC free HCFC free Zero Ozone Depletion Potential (ODP) Taking care of energy and Environment PROFLEX Proflex polyolefin foam thermal insulation for AirConditioning,

More information

Environmental credentials. Energy efficiency and environmental protection with KIMMCO glass mineral wool

Environmental credentials. Energy efficiency and environmental protection with KIMMCO glass mineral wool SAINT-GOBAIN Environmental credentials. Energy efficiency and environmental protection with KIMMCO glass mineral wool More and more specifiers and users are insisting on the use of insulation materials

More information

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Xtratherm Thin-R Thermal Liner (XT/TL Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 4 Xtratherm Thin-R Thermal Liner (XT/TL Grade) PRODUCT DESCRIPTION: This Detail Sheet relates to Xtratherm Thin-R Thermal Liner, as defined in NSAI Agrément Certificate

More information

M I N I C O L D R O O M TECHNICAL SPECIFICATIONS

M I N I C O L D R O O M TECHNICAL SPECIFICATIONS M I N I C O L D R O O M TECHNICAL SPECIFICATIONS Page.1 INTRODUCTION The Isark range, within the ColdKit range of cold rooms, was developed to combine: Aesthetics and quality Ease of transport and assembly

More information

Techna-Duc. Advantages. Features and Benefits. LEED Eligible Product

Techna-Duc. Advantages. Features and Benefits. LEED Eligible Product Techna-Duc Advantages Techna-Duc is shop fabricated and installed with minimal field alterations. Panels are constructed with polyisocyanurate insulation products that do not promote the growth of mold

More information

REFERENCE ARMA-CHEK SILVER

REFERENCE ARMA-CHEK SILVER REFERENCE ARMA-CHEK SILVER LENZING GROUP S LYOCELL FIBRE PLANT www.armacell.com Arma-Chek Silver in the world s largest lyocell plant Austrian Vöcklabruck district is the site of Europe s biggest ever

More information

REFERENCE ARMA-CHEK SILVER

REFERENCE ARMA-CHEK SILVER REFERENCE LENZING GROUP S LYOCELL FIBRE PLANT www.armacell.com Arma-Chek Silver in the world s largest lyocell plant Austrian Vöcklabruck district is the site of Europe s biggest ever Arma-Chek project

More information

Ductslab and Ductwrap

Ductslab and Ductwrap CONSTRUCTION TYPE: DUCTS AND TANKS Ductslab and Ductwrap For the thermal insulation of ductwork and water storage tanks ROCKWOOL provide thermal insulation for air conditioning, warm air and extract ducts

More information

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Xtratherm Thin-R Thermal Liner (XT/TL Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 4 Xtratherm Thin-R Thermal Liner (XT/TL Grade) PRODUCT DESCRIPTION: This Detail Sheet relates to Xtratherm Thin-R Thermal Liner, as defined in NSAI Agrément Certificate

More information

DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks.

DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks. DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks. DUCTWRAP AND DUCTSLAB ROCKWOOL Ductwrap and Ductslab provide thermal insulation for air conditioning, warm air and

More information

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 1 Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) PRODUCT DESCRIPTION This Detail Sheet relates to Xtratherm Thin-R Partial Fill Cavity Wall Board, as

More information

This specification describes the minimum requirements for industrial thermal insulation.

This specification describes the minimum requirements for industrial thermal insulation. 016/09/7 1/7 1.0 PURPOSE This specification describes the minimum requirements for industrial thermal insulation. Read it in conjunction with the applicable insulation and insulation finish specifications

More information

a d v a n c e d e l a s t o m e r i c t h e r m a l a n d a c o u s t i c i n s u l a t i o n m a t e r i a l s

a d v a n c e d e l a s t o m e r i c t h e r m a l a n d a c o u s t i c i n s u l a t i o n m a t e r i a l s a d v a n c e d e l a s t o m e r i c t h e r m a l a n d a c o u s t i c i n s u l a t i o n m a t e r i a l s G E N E R A L O V E RV I E W O F P R O D U C T S A N D S Y S T E M S CFC and HCFC-free insulation

More information

August 2008: Issue 1. Non - Residential New Build Built - up Metal Walls

August 2008: Issue 1. Non - Residential New Build Built - up Metal Walls Non - Residential New Build 4.3.1 Built - up Metal Walls August 2008: Issue 1 Non-residential new build 4.0 Non-residential New Build Built-up Metal Walls Contents Introduction find online page Solution

More information

DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks.

DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks. DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks. DUCTWRAP AND DUCTSLAB ROCKWOOL Ductwrap and Ductslab provide thermal insulation for air conditioning, warm air and

More information

SMART Plus Radiant Panel

SMART Plus Radiant Panel SMART Plus Radiant Panel www.merriott-radiators.com We strive to offer world class manufacturing of bespoke heating solutions in the UK and Ireland. Our unwavering commitment to sustainability and enthusiasm

More information

Gulf Cool Therm Polyurethane (PUR) Insulation

Gulf Cool Therm Polyurethane (PUR) Insulation Gulf Cool Therm Polyurethane (PUR) Insulation Cold Insulation for Oil, Gas and Refinery Industries Cryogenic Insulation Pipe, Slabs and Board Insulation The Quality Insulation Products for Many Diverse

More information

for automatic doors Range of LEAVES

for automatic doors Range of LEAVES Range of LEAVES for automatic doors As key elements of the Automatic Door, leaves are, good reason, essential components for your comfort and safety Thermal and acoustic comfort Property and personal security

More information

Insulation AN INTRODUCTION. Low Energy Low Carbon Buildings. Fourth Issue August 2018

Insulation AN INTRODUCTION. Low Energy Low Carbon Buildings. Fourth Issue August 2018 Insulation Fourth Issue August 2018 The Kingspan AN INTRODUCTION System Low Energy Low Carbon Buildings Introduction Overview Traditionally, HVAC ductwork is constructed from galvanised sheet steel, which

More information

PROJ. NO SECTION HVAC DUCT INSULATION

PROJ. NO SECTION HVAC DUCT INSULATION SECTION 23 07 13 HVAC DUCT INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 07 4243 - PART 1 GENERAL 1.01 SECTION INCLUDES A. Composite wall panel system consisting of aluminum-faced composite panels in a rainscreen application as part of the assembly described below.

More information

KIMMCO RIGID PIPE COVERING (K450 Plus)

KIMMCO RIGID PIPE COVERING (K450 Plus) KIMMCO RIGID PIPE COVERING (K450 Plus) www.kimmco.com Company Profile KIMMCO (Kuwait Insulating Material Manufacturing Co.), a subsidiary of Alghanim Industries, was established in Kuwait in1977. It has

More information

Insulation AN INTRODUCTION. Low Energy Low Carbon Buildings. Third Issue September 2017

Insulation AN INTRODUCTION. Low Energy Low Carbon Buildings. Third Issue September 2017 Insulation Third Issue September 2017 The Kingspan AN INTRODUCTION System Low Energy Low Carbon Buildings Introduction Overview Traditionally, HVAC ductwork is constructed from galvanised sheet steel,

More information

FOR FURTHER INFORMATION ON THE KOOLTHERM RANGE OF PRODUCTS PLEASE TELEPHONE THE KINGSPAN TECHNICAL SERVICES DEPARTMENT (01457)

FOR FURTHER INFORMATION ON THE KOOLTHERM RANGE OF PRODUCTS PLEASE TELEPHONE THE KINGSPAN TECHNICAL SERVICES DEPARTMENT (01457) FOR FURTHER INFORMATION ON THE KOOLTHERM RANGE OF PRODUCTS PLEASE TELEPHONE THE KINGSPAN TECHNICAL SERVICES DEPARTMENT (01457) 861611 INDUSTRIAL INSULATION Kingspan Industrial Insulation Limited PO Box

More information

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Insulation. A4/8 KDINT AW2143 Issue 4 Oct An Introduction

Insulation. A4/8 KDINT AW2143 Issue 4 Oct An Introduction Insulation A4/8 KDINT AW2143 Issue 4 Oct 2016 The Kingspan An Introduction System Introduction Overview The heating, ventilation and air conditioning (HVAC) industry is in the midst of a dynamic era, however

More information

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket.

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket. SECTION 230719 - HVAC PIPING INSULATION PART 1 GENERAL 1.1 SECTION INCLUDES A. Piping insulation. B. Jackets and accessories. 1.2 RELATED REQUIREMENTS A. Section 07813 - Fire Procection, HVAC & Plumbing

More information

TECHNOLOGY IS ON OUR SIDE ECONOMY ABOVE ALL

TECHNOLOGY IS ON OUR SIDE ECONOMY ABOVE ALL WOODEN STRUCTURES TECHNOLOGY IS ON OUR SIDE Spans of up to 150 meters and proven membrane technology have made DUOL well-known far beyond its borders; one of Europe s most modern CNC-controlled production

More information

Addendum 1 Section THERMAL INSULATION FOR PIPING Burrow Avenue Pumping Station Upgrades Page 1 of 5

Addendum 1 Section THERMAL INSULATION FOR PIPING Burrow Avenue Pumping Station Upgrades Page 1 of 5 Burrow Avenue Pumping Station Upgrades Page 1 of 5 Part 1 General 1.1 SUMMARY.1 Section Includes:.1 Thermal insulation for piping and piping accessories in commercial type applications. 1.2 REFERENCES.1

More information

An all-in-one system that combines the advantages of Kingspan KoolDuct with the durability of Techna-Duc, and is suitable for indoor and outdoor

An all-in-one system that combines the advantages of Kingspan KoolDuct with the durability of Techna-Duc, and is suitable for indoor and outdoor An all-in-one system that combines the advantages of Kingspan KoolDuct with the durability of Techna-Duc, and is suitable for indoor and outdoor applications. Description Dual-Tech TM is an all-in-one,

More information

QuadCore Controlled Environment Series Food Processing Datasheet

QuadCore Controlled Environment Series Food Processing Datasheet Insulated Panel Envelope Systems Roof Wall Façades Lighting Rooftop PV Steel Coldstore Cleanrooms UK & Ireland QuadCore Controlled Environment Series Food Processing Datasheet UltraTemp Insulated Panels

More information

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated.

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated. SECTION 23 07 13 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

ACOUSTIC BARRIERS DWX SERIES FOR DUCTWORK

ACOUSTIC BARRIERS DWX SERIES FOR DUCTWORK DWX SERIES ACOUSTIC BARRIERS FOR DUCTWORK A SOFT FLEXIBLE QUILT WITH AN OUTER HEAVY POLYMERIC ACOUSTIC MEMBRANE, OFFERING EXCELLENT DURABILITY AND SOUND INSULATION QUALITIES, THAT CAN BE USED IN A VARIETY

More information

Division 15 INSULATION Section 15100

Division 15 INSULATION Section 15100 Page 1 of 5 SECTION PAGE PART 1 GENERAL 2 1.1 General 2 1.2 References 2 1.3 Work Included 2 1.4 Related Work 2 1.5 Quality Assurance 3 PART 2 PRODUCTS 3 2.1 Description 3 PART 3 EXECUTION 3 3.1 Workmanship

More information

Foamed-in-place insulation Sprayed insulation. Spray Foam Insulation for Residential Building Envelope Insulation

Foamed-in-place insulation Sprayed insulation. Spray Foam Insulation for Residential Building Envelope Insulation 07 21 19 Foamed-in-place insulation 07 21 29 Sprayed insulation Spray Foam Insulation for Residential Building Envelope Insulation PART 1 - GENERAL 1.1 SUMMARY This document discusses the application of

More information

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Linx Industries. Your Source for Lindab Products.

Linx Industries. Your Source for Lindab Products. Linx Industries Your Source for Lindab Products www.li-hvac.com Linx Industries, Inc. is an American-based manufacturing company which develops, manufactures, and markets sheet metal products and system

More information

SECTION DETECTABLE GUIDE TACTILES

SECTION DETECTABLE GUIDE TACTILES SECTION 09655 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for surface applied and recessed detectable guide or directional tactiles (tactiles) for use on the station platforms

More information

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation.

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation. SECTION 15083 HVAC DUCT PROTECTION OVER INSULATION FlexClad This section is based on the products of MFM Building Products Corp., which is located at: 525 Orange St. P. O. Box 340 Coshocton, OH 43812 Toll

More information

Acoustic Louvres. Product and Technical Data

Acoustic Louvres. Product and Technical Data Acoustic Louvres Product and Technical Data INDUSTRIAL & ENVIRONMENTAL NOISE CONTROL SOLUTIONS WORLDWIDE PRODUCT DESCRIPTION Wakefield Acoustics specialises in the design and fabrication of a wide range

More information

PIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D

PIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D PIPEWORK INSULATION 14/10-2014 Page 1 of 10 Pipework Insulation Rev D Contents INTRODUCTION General Scope Surfaces to be Insulated Pumps, Turbines etc Performance Minimum Pipe Insulation Thickness Physical

More information

Insulation engineered to prevent condensation and energy loss

Insulation engineered to prevent condensation and energy loss Insulation engineered to prevent condensation and energy loss Triple security: effective condensation control, FM Approved and excellent fire performance Highly energy efficient to give long-term energy-saving

More information

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System SECTION 13096 RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13096-1 RF MODULAR PAN SYSTEM PART 1 GENERAL 1.1

More information

KingZip IP Standing Seam Insulated Panel KS500/1000 ZIP IP Data Sheet

KingZip IP Standing Seam Insulated Panel KS500/1000 ZIP IP Data Sheet Insulated Panel Systems United Kingdom Standing Seam Insulated Panel Data Sheet Applications The is a unique insulated standing seam roof panel, which give a secret-fix appearance unrivalled in the composite

More information

Knauf Data Sheet AH-DS-5E Friendly Feel. Duct Wrap. with ECOSE Technology

Knauf Data Sheet AH-DS-5E Friendly Feel. Duct Wrap. with ECOSE Technology Knauf Data Sheet AH-DS-5E 07-09 Friendly Feel with ECOSE Technology Duct Wrap For cooling, heating or dual temperature service. Friendly Feel Duct Wrap meets the most stringent IAQ tests GREENGUARD Children

More information

Sliding Door Systems

Sliding Door Systems Sliding Door Systems Standard Sliding System Reference Brand: Sapa Building System Plaisance 24 GENERAL DESCRIPTION Sliding window and door system with a frame depth of 50 mm (two rail version), 97mm (three

More information

EXPERIENCE COUNTS! Specializing in more than just products we put the competitive advantage at your fingertips.

EXPERIENCE COUNTS! Specializing in more than just products we put the competitive advantage at your fingertips. EXPERIENCE COUNTS! Specializing in more than just products we put the competitive advantage at your fingertips. Armaflex is a flexible, closed cell, elastomeric, nitrile rubber, insulation. It is a highly

More information

Tube Insulation. Fiber Free

Tube Insulation. Fiber Free Fiber Free Tube Insulation Fiber-free, flexible, elastomeric pipe insulation for reliable protection against condensation, mold, energy loss and ultraviolet radiation in residential and commercial applications

More information

Insulated Roof & Wall Panels Solutions. Product Data Sheet. X-Dek Multi-Span Insulated Roof Panel KS1000 XD Multi-Span

Insulated Roof & Wall Panels Solutions. Product Data Sheet. X-Dek Multi-Span Insulated Roof Panel KS1000 XD Multi-Span Insulated Roof & Wall Panels Solutions X-Dek Insulated Roof Panel KS1000 XD Dimensions, Weight & Thermal Performance X-Dek 50 X-Dek 70 Core Thickness (mm) 46 66 Overall Thickness (mm) 154 174 U-value (W/m²K)

More information

GUIDE SPECIFICATION: MECHANICAL SYSTEMS

GUIDE SPECIFICATION: MECHANICAL SYSTEMS GUIDE SPECIFICATION: MECHANICAL SYSTEMS This specification guide includes thermal & acoustical insulation for piping, equipment, vessels, and air handling systems. This section is based on the format recommended

More information

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION SECTION 230713 DUCT INSULATION PART 1 GENERAL 1.1 SUMMARY A. Related Sections: 1. 233113 Ductwork and Accessories 1.2 REFERENCES A. American Society for Testing and Materials (ASTM): 1. E84-96a Test Method

More information

4257M METALCRAFT INSULATED PANEL SYSTEMS

4257M METALCRAFT INSULATED PANEL SYSTEMS 4257M METALCRAFT INSULATED PANEL SYSTEMS 1. GENERAL This section relates to the fabrication, supply and installation of prepainted steel clad, insulating panels and cladding system for ambient controlled

More information

Facade panel PICTURA Product Information Sheet

Facade panel PICTURA Product Information Sheet Facade panel PICTURA Product Information Sheet 1 Product range PICTURA fibre cement facade panels are made from: Portland cement Mineral filler Natural organic fibres (cellulose), synthetic organic fibres

More information

sound absorber for challenging environments sound absorber for challenging environments

sound absorber for challenging environments sound absorber for challenging environments R sound absorber for challenging environments sound absorber for challenging environments the sound absorber for challenging environments Reapor was developed to maximise noise energy absorption. Reapor

More information

B C M T e c h n i c a l, L L C A v o n I n d u s t r i a l D r. R o c h e s t e r H i l l s, M I P h o n e : T o l

B C M T e c h n i c a l, L L C A v o n I n d u s t r i a l D r. R o c h e s t e r H i l l s, M I P h o n e : T o l P r o d u c t C a t a l o g w w w. p i p e i n s u l a t i o n. n e t B C M T e c h n i c a l, L L C 2 1 7 5 A v o n I n d u s t r i a l D r. R o c h e s t e r H i l l s, M I 4 8 3 0 9 P h o n e : 2 4

More information

CONSTRUCTIVE ROOFING SOLUTIONS

CONSTRUCTIVE ROOFING SOLUTIONS CONSTRUCTIVE ROOFING SOLUTIONS Farming, Industrial and Housing Applications WITHOUT ASBESTOS FIBER CEMENT 03 Agrotherm Plus 08 Naturtherm Plus 10 Granonda 12 Minionda 13 Underlay 15 Complements and accessories

More information

PlyLok. Product Guide PIR and Plywood Laminate Insulation for Warm Flat Roofs.

PlyLok. Product Guide PIR and Plywood Laminate Insulation for Warm Flat Roofs. PlyLok Product Guide PIR and Plywood Laminate Insulation for Warm Flat Roofs. Introduction The Company. Driven by a culture of innovation, technical competence and flair, Recticel Insulation Products is

More information

SECTION DUCTS PART 1 GENERAL 1.01 SUMMARY

SECTION DUCTS PART 1 GENERAL 1.01 SUMMARY 1 1 1 1 1 1 1 1 0 1 0 1 SECTION 1 DUCTS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Duct Materials.. Insulated flexible ducts.. Single wall spiral round ducts.. Ductwork fabrication.. Duct cleaning.

More information

Palight. Flat Foamed PVC Sheet. Tel: +44 (0) Fax: +44 (0)

Palight. Flat Foamed PVC Sheet. Tel: +44 (0) Fax: +44 (0) Palight Flat Foamed PVC Sheet Content Introduction 2 Main Benefits 2 Palight Product Range 2 Colours 3 Typical Applications 4 Standard Dimensions 8 Flammability 8 Product Masking 8 Typical Physical Properties

More information

FOR FURTHER INFORMATION ON THE NILFLAM RANGE OF PRODUCTS PLEASE TELEPHONE THE KINGSPAN TECHNICAL SERVICES DEPARTMENT (01457)

FOR FURTHER INFORMATION ON THE NILFLAM RANGE OF PRODUCTS PLEASE TELEPHONE THE KINGSPAN TECHNICAL SERVICES DEPARTMENT (01457) FOR FURTHER INFORMATION ON THE NILFLAM RANGE OF PRODUCTS PLEASE TELEPHONE THE KINGSPAN TECHNICAL SERVICES DEPARTMENT (01457) 861611 INDUSTRIAL INSULATION Kingspan Industrial Insulation Limited PO Box 3,

More information

Controlled Environments. Product Data Sheet

Controlled Environments. Product Data Sheet Controlled Environments Product Data Sheet UltraTemp Insulated Panels for Cold Storage Applications with a Temperature Range of -40 C to +0 C Product Data Sheet Applications UltraTemp insulated roof, wall

More information

Capital Projects Group Air Terminal Units Specification

Capital Projects Group Air Terminal Units Specification Capital Projects Group Air Terminal Units Specification Specification 23 36 00 Revision 0 Date: August 2018 Air Terminal Units Specification Specification 23 36 00 Publication Date: August 2018 COPYRIGHT

More information

Mechanically Fasten Duct Sections. Code Reference: 2013 Title 24, Part 6 Standards 120.4(a) Sealed Openings. Drawbands

Mechanically Fasten Duct Sections. Code Reference: 2013 Title 24, Part 6 Standards 120.4(a) Sealed Openings. Drawbands DUCTS - SEALING R-H-DS1 Mechanically Fasten Duct Sections Sections of metal duct should be mechanically fastened together after taping seams with UL 181 duct tape. Use sheet metal screws for rigid duct

More information

outdoor ducts system C C

outdoor ducts system C C C outdoor ducts system C Outdoor ducts: a plant design necessity. The solutions currently offered by designers involve more and more often the development, sometimes even partial, of the air duct system

More information

Coated Aluminium Strip. Aluminium

Coated Aluminium Strip. Aluminium Coated Aluminium Strip Aluminium Coated rolled products from Hydro highly versatile Hydro Aluminium s Business Unit Strip focuses on the production of plain and converted aluminium strip for specially

More information

INSULATION MATERIALS MANUFACTURING

INSULATION MATERIALS MANUFACTURING INSULATION MATERIALS MANUFACTURING PUR/PIR Insulation Foam Board PUR/PIR PrePre-Insulated Duct Panels/Fabricated Ducts PUR/PIR FOAM FOR THERMAL INSULATION (Wall External/Internal, Roof, Cladding, Ceiling,

More information

CLIMAVER ductwork system. Saves valuable space, reduces installation time and is more cost-effective

CLIMAVER ductwork system. Saves valuable space, reduces installation time and is more cost-effective CLIMAVER ductwork system Saves valuable space, reduces installation time and is more cost-effective The CLIMAVER pre-insulated ductwork system solution enables you to meet the thermal, acoustic and fire

More information

JOHNS MANVILLE CONTINUOUS INSULATION WALL SYSTEM MASTER SPECIFICATION June 2014 CSI FORMAT SECTION FOIL-FACED RIGID INSULATION

JOHNS MANVILLE CONTINUOUS INSULATION WALL SYSTEM MASTER SPECIFICATION June 2014 CSI FORMAT SECTION FOIL-FACED RIGID INSULATION CSI FORMAT SECTION PART 1 - GENERAL 1.1 SUMMARY A. Provide foil-faced thermal insulation in exterior wall assemblies, to function as a thermal, moisture, and air barrier wall system. 1.2 RELATED WORK A.

More information

Palopaque. Wall Cladding Solutions. Tel: +44 (0) Fax: +44 (0)

Palopaque. Wall Cladding Solutions. Tel: +44 (0) Fax: +44 (0) Palopaque Wall Cladding Solutions Tel: +44 (0) 191 258 0777 Fax: +44 (0) 191 258 1010 Email: sales@bayplastics.co.uk Tel: +44 (0) 191 258 0777 Fax: +44 (0) 191 258 1010 Email: sales@bayplastics.co.uk Content

More information

K15 Rainscreen Board. Insulation INSULATION FOR USE BEHIND RAINSCREEN CLADDING SYSTEMS

K15 Rainscreen Board. Insulation INSULATION FOR USE BEHIND RAINSCREEN CLADDING SYSTEMS Insulation A4/6 K15 AW2161 Issue 3 Dec 2016 INSULATION FOR USE BEHIND RAINSCREEN CLADDING SYSTEMS Super high performance rigid thermoset phenolic insulation Fibre-free, closed cell insulation core Suitable

More information

METRA. THE ONLY COMPANY TO OFFER A COMPLETE RANGE OF PRODUCTS

METRA. THE ONLY COMPANY TO OFFER A COMPLETE RANGE OF PRODUCTS NC-S 0 STH Certified performances The METRA window or door has not had any seepage of water even with a wind pressure equal to a speed of 96,9 Km/h (0Pa). km/h (0Pa) (0Pa) (00Pa) (0Pa) (00Pa) (0Pa) (00Pa)

More information

Lamit Industries Nailbase Panels General Recommendations

Lamit Industries Nailbase Panels General Recommendations Lamit Industries Nailbase Panels General Recommendations Lamit Industries Nailbase Panels Sizes Lamit Industries Nailbase Panels are made in a variety of sizes; most commonly 4 x 8. Consult Lamit Industries

More information

Revision:C Pipework Insulation Issued:14/11/2012 PIPEWORK INSULATION CU14. 14/11/2012 Page 1 of 10 Pipework Insulation - RevC

Revision:C Pipework Insulation Issued:14/11/2012 PIPEWORK INSULATION CU14. 14/11/2012 Page 1 of 10 Pipework Insulation - RevC PIPEWORK INSULATION CU14 14/11/2012 Page 1 of 10 - RevC Contents INTRODUCTION 5 General 5 Scope 5 Surfaces to be Insulated 5 Pumps, Turbines etc 5 Performance 6 Minimum Pipe Insulation Thickness 6 Physical

More information

Exterior Wall Solutions Building Shell

Exterior Wall Solutions Building Shell A strong, water tight and thermally insulated building shell will ensure the buildings sustainability of usage over time. The Exterior Shell is the most important factor of protection to ensure that the

More information

SECTION AWNINGS

SECTION AWNINGS SECTION 10 73 13 AWNINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Fixed metal awnings. 1.2 DEFINITIONS A. Awning: An architectural projection that provides weather protection,

More information

Textura Façade panel Product information sheet 1

Textura Façade panel Product information sheet 1 Textura Façade panel Product information sheet 1 1 Product range Textura fibre cement facade panels are made from: Portland cement Mineral filler Natural organic fibres (cellulose), synthetic organic fibres

More information

MANUFACTURING DIVISION

MANUFACTURING DIVISION www.rapidcool.ae 1 1 www.rapidcool.ae www.rapidcool.ae 2 ABOUT US Established in 1995 through a small trading office in Dubai, Rapid Cool Group of Companies is a leading supplier of high quality products

More information

SECTION AIR DUCT CLEANING

SECTION AIR DUCT CLEANING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

SOUND BARRIER WALLS. Specializing in Acoustics, Noise & Vibration Control. Phone Fax Penn Street Westfield, IN 46074

SOUND BARRIER WALLS. Specializing in Acoustics, Noise & Vibration Control. Phone Fax Penn Street Westfield, IN 46074 SOUND BARRIER WALLS Specializing in Acoustics, Noise & Vibration Control 129 Penn Street Westfield, IN 46074 Phone Fax 317-774-1911 www.enoisecontrol.com info@enoisecontrol.com Barrier Wall Systems Industrial,

More information