TECHNICAL DESCRIPTION OF UNIT Nos. 12, 22, 32, 42. reconstructed units

Size: px
Start display at page:

Download "TECHNICAL DESCRIPTION OF UNIT Nos. 12, 22, 32, 42. reconstructed units"

Transcription

1 DESCRIPTION material/type/modification status EXTERIOR WINDOWS scuntion windows INTERIOR DOORS entrance door to unit historical replicas - wooden frame, 1x thermal insulated double glazing and 1x simple glazing historical replicas - fire resistant security doors - wooden single door in casing frame doors inside unit casing non-rebated door mm, CPL white HEATING central gas boiler room heater - smooth white WATER MAINS cold water pipes PP pipes of the appropriate size, thermal insulation warm water pipes PP pipes of the appropriate size, thermal insulation SEWAGE sewage pipes PP HT pipes ELECTRICAL MAINS electrical wiring CYKY cable television antenna DVBT/FM and SAT signal wiring, coaxial cable, TV/FM/SAT socket telephone lines UTP cat 5e cables, double SKS outlet data lines cable protective casing + coaxial cables building phone lines video telephone device, cable FLOOR COVERING front hall, bathroom, WC ceramic 200x200 mm tiles living rooms floor with wooden treading layer - rustic oak, "triple board" BATHROOM and WC fittings, water taps Jika Cubito, single-lever tap shower stall: shower tray from cast marble, glass partition walls ceramic 200x200 mm tiles SURFACE TREATMENT plaster stucco cement-lime plaster, paint repaired in 2017 ceilings gypsum board ceiling, paint MEASUREMENT OF ENERGY CONSUMPTION drinking water water meter in unit, remote reading electricity unit electric meter in area of stairwell heat meter in unit, remote reading * The right to change materials, configuration and dates is reserved. Explanation of statuses: TECHNICAL DESCRIPTION OF UNIT Nos. 12, 22, 32, 42 Dalimilova 925/11, Prague 3 - Rezidence U Kronikáře reconstructed units "" - Indicates the delivery or implementation of entirely new structures, elements, wiring, items, etc. as part of the structural modifications of the units and the common parts of the building. The guarantee pursuant to the relevant paragraph of the Purchase Agreement applied to the parts of the units with the designation of "new" with a specification of the year of implementation or acquisition. "original" - indicates the original condition of the specified structure, element, wiring, fittings of the unit, on which no repairs, modifications, or revisions have taken place, there have been no interventions on them of any kind and they can show deviations from current standards or norms. "revision in 2017" - There was only a review on the system, wiring, device or equipment in question in the given year to guarantee its safe functionality. A guarantee pursuant to the relevant paragraph of the Purchase Agreement applies to these parts of the units with the "revision" designation. "repaired in 2017" - repairs guarnateeing the status after the performance of work necessary for the renewal/improvement of the appearance and primarily to ensure the correct functionality. The repairs take place in the form of local or full surface treatment, in the form of the adjustment, addition or exchange or some of the elements. During the repairs the functions or visual or other parameters corresponding to the status of "New" are never reached. Notes to the Technical Description / Standards (Description of selected structures, elements, materials, items and systems) Flat and Common parts of block of flats:

2 Exterior doors and windows - due to external conditions (temperature changes, aging of construction, loading, etc.) there can be an imperceptible deviation of the windows, i.e. "slack", which is exhibited by abutting on the frame, a lack of sealing or difficulty in opening the window. In this case this is considered to be a frequent phenomenon, which is not caused by a product or assembly defect and thus cannot be claimed. In the event that such a phenomenon arises, it is necessary to ensure the adjustment of the window without great delay. The service is a matter of regular maintenance and is performed by the client at its own expense. The functional joints of the original windows may not seal completely, leading to a larger than usual amount of external air leaking into the interior. Interior and entrance doors - if there is "slack" in the doors, the situation and approach is the same as in the case of "Exterior doors and windows" (see above) - the adjustment of the door is provided by the client at its own expense. During the assembly of new doors on the original frames, the door may not sit well on the frame, leading to the more difficult closing or locking of the door. Floor treading layer - In the case of "New" this is only the delivery of floor coverings and not the complete implementation of the floor. Thus the contractor is only responsible for the quality of the assemby and the material of the treading layer. In the case of the original treading layer there may be some sag, some manifestations of noise (creaches, etc.) and/or the imperfect sealing of the joints of the individual flooring elements. Walls, ceilings - in light of the historical character of the building, it is necessary to expect deviations from the parameters prescribed by the current valid norms (ČSN). Primarily the flatness and verticality of the structure, the perpendicularity of the structural joints, etc. may not be maintained. Due to the load the original wooden load-bearing ceiling structures can be bent and can also lead to the uneveness of the floor's treading layer. Acoustics - the fulfilment of acoustic standards cannot be guaranteed for walls between flats and floor structures, the structure or the actual construction of which has not been altered, except for the treading layer. This applies primarily to the damping of impact noise and sound-transmission loss. The guarantee does not apply to the characteristics of the original dividing structures. Underground floors of the block of flats - in light of the historical character of the building and its technical design, it is necessary to point out the possibility of the permeation of moisture through the circumference wall and the floor. Balconies, terraces - for the original structures, where the exchange of the treading layers has not been performed, some places with an insufficient drainage of rain water can be expected. These phenomena are caused primarily by the poor weathered pointing of the horizontal structure. Façade - climatic phenomena (rain, changes of temperatures,...) can lead to the occurrence of microfissures and the disruption of the plaster, primarily in the places under the greatest strain, e.g. the plinths of the circumference wall. Connection of structures on the exterior of the building - Connecting two or more structures can, in time, lead to the creation of smaller or larger cracks in the connections/joints. This phenomenon is caused by the influence of different physical characteristics of the materials and changes in climatic conditions. The creation of joints usually has no effect on the technical characteristics or safety of the use of the building.

3 DESCRIPTION material/type/modification status EXTERIOR WINDOWS EURO windows scuntion windows VÝPLNĚ VNITŘNÍCH OTVORŮ entrance door to unit entrance doors to unit no. 13 wooden windows and balcony doors - thermal insulated double glazing historical replicas - wooden frame, 1x thermal insulated double glazing and 1x simple glazing historical replicas - fire resistant security doors - wooden single door in casing frame historical - fire resistant security doors - wooden double doors in casing frame renovated in 2017 doors inside unit casing non-rebated door mm, CPL white HEATING central gas boiler room heater - smooth white WATER MAINS cold water pipes PP pipes of the appropriate size, thermal insulation warm water pipes PP pipes of the appropriate size, thermal insulation SEWAGE sewage pipes PP HT pipes ELECTRICAL MAINS electrical wiring CYKY cable television antenna DVBT/FM and SAT signal wiring, coaxial cable, TV/FM/SAT socket telephone lines UTP cat 5e cables, double SKS outlet data lines cable protective casing + coaxial cables building phone lines video telephone device, cable FLOOR COVERING front hall, bathroom, WC ceramic 200x200 mm tiles living rooms floor with wooden treading layer - rustic oak, "triple board" BATHROOM and WC fittings, water taps Jika Cubito, single-lever tap shower stall: shower tray from cast marble, glass partition walls ceramic 200x200 mm tiles SURFACE TREATMENT plaster stucco cement-lime plaster, paint repaired in 2017 ceilings gypsum board ceiling, paint MEASUREMENT OF ENERGY CONSUMPTION drinking water water meter in unit, remote reading electricity unit electric meter in area of stairwell heat meter in unit, remote reading BALCONIES TECHNICAL DESCRIPTION OF UNIT Nos. 13, 23, 33, 43 Dalimilova 925/11, Prague 3 - Rezidence U Kronikáře reconstructed units floor, railing ceramic tiling, metal railing balcony fittings electrical outlet, lights * The right to change materials, configuration and dates is reserved. Explanation of statuses: "" - Indicates the delivery or implementation of entirely new structures, elements, wiring, items, etc. as part of the structural modifications of the units and the common parts of the building. The guarantee pursuant to the relevant paragraph of the Purchase Agreement applied to the parts of the units with the designation of "new" with a specification of the year of implementation or acquisition. "original" - indicates the original condition of the specified structure, element, wiring, fittings of the unit, on which no repairs, modifications, or revisions have taken place, there have been no interventions on them of any kind and they can show deviations from current standards or norms. "revision in 2017" - There was only a review on the system, wiring, device or equipment in question in the given year to guarantee its safe functionality. A guarantee pursuant to the relevant paragraph of the Purchase Agreement applies to these parts of the units with the "revision" designation. "repaired in 2017" - repairs guarnateeing the status after the performance of work necessary for the renewal/improvement of the appearance and primarily to ensure the correct functionality The repairs take place in the form of local or full surface treatment in the

4 appearance and primarily to ensure the correct functionality. The repairs take place in the form of local or full surface treatment, in the form of the adjustment, addition or exchange or some of the elements. During the repairs the functions or visual or other parameters corresponding to the status of "New" are never reached. Notes to the Technical Description / Standards (Description of selected structures, elements, materials, items and systems) Flat and Common parts of block of flats: Exterior doors and windows - due to external conditions (temperature changes, aging of construction, loading, etc.) there can be an imperceptible deviation of the windows, i.e. "slack", which is exhibited by abutting on the frame, a lack of sealing or difficulty in opening the window. In this case this is considered to be a frequent phenomenon, which is not caused by a product or assembly defect and thus cannot be claimed. In the event that such a phenomenon arises, it is necessary to ensure the adjustment of the window without great delay. The service is a matter of regular maintenance and is performed by the client at its own expense. The functional joints of the original windows may not seal completely, leading to a larger than usual amount of external air leaking into the interior. Interior and entrance doors - if there is "slack" in the doors, the situation and approach is the same as in the case of "Exterior doors and windows" (see above) - the adjustment of the door is provided by the client at its own expense. During the assembly of new doors on the original frames, the door may not sit well on the frame, leading to the more difficult closing or locking of the door. Floor treading layer - In the case of "New" this is only the delivery of floor coverings and not the complete implementation of the floor. Thus the contractor is only responsible for the quality of the assemby and the material of the treading layer. In the case of the original treading layer there may be some sag, some manifestations of noise (creaches, etc.) and/or the imperfect sealing of the joints of the individual flooring elements. Walls, ceilings - in light of the historical character of the building, it is necessary to expect deviations from the parameters prescribed by the current valid norms (ČSN). Primarily the flatness and verticality of the structure, the perpendicularity of the structural joints, etc. may not be maintained. Due to the load the original wooden load-bearing ceiling structures can be bent and can also lead to the uneveness of the floor's treading layer. Acoustics - the fulfilment of acoustic standards cannot be guaranteed for walls between flats and floor structures, the structure or the actual construction of which has not been altered, except for the treading layer. This applies primarily to the damping of impact noise and sound-transmission loss. The guarantee does not apply to the characteristics of the original dividing structures. Underground floors of the block of flats - in light of the historical character of the building and its technical design, it is necessary to point out the possibility of the permeation of moisture through the circumference wall and the floor. Balconies, terraces - for the original structures, where the exchange of the treading layers has not been performed, some places with an insufficient drainage of rain water can be expected. These phenomena are caused primarily by the poor weathered pointing of the horizontal structure. Façade - climatic phenomena (rain, changes of temperatures,...) can lead to the occurrence of microfissures and the disruption of the plaster, primarily in the places under the greatest strain, e.g. the plinths of the circumference wall. Connection of structures on the exterior of the building - Connecting two or more structures can, in time, lead to the creation of smaller or larger cracks in the connections/joints. This phenomenon is caused by the influence of different physical characteristics of the materials and changes in climatic conditions. The creation of joints usually has no effect on the technical characteristics or safety of the use of the building.

5 TECHNICAL DESCRIPTION OF UNIT Nos. 51 a 52 Dalimilova 925/11, Prague 3 - Rezidence U Kronikáře reconstructed units DESCRIPTION material/type/modification status EXTERIOR WINDOWS atelier windows metal, swivel fields - thermal insulated double glazing skylights wooden swivel windows - thermal insulated double glazing glazed walls set of large metal sliding (lifting) windows, thermal insulated double glazing INTERIOR DOORS entrance door to unit replicas of originals - fire resistant security doors - wooden single door in casing frame doors inside unit casing non-rebated door mm, CPL white HEATING central gas boiler room heater - smooth white, floor convectors WATER MAINS cold water pipes PP pipes of the appropriate size, thermal insulation warm water pipes PP pipes of the appropriate size, thermal insulation SEWAGE sewage pipes PP HT pipes ELECTRICAL MAINS electrical wiring CYKY cable television antenna DVBT/FM and SAT signal wiring, coaxial cable, TV/FM/SAT socket telephone lines UTP cat 5e cables, double SKS outlet data lines cable protective casing + coaxial cables building phone lines video telephone device, cable AIR CONDITIONING multisplit system separate exterior condensation unit for unit, interior wall-mounted cooling unit, smooth white FLOOR COVERING, STAIRS front hall, bathroom, WC ceramic 200x200 mm tiles, including shower stall living rooms floor with wooden treading layer - rustic oak, "one board" storage space Oriented strand boards stairs attic fold-up stairs with a wooden ladder BATHROOM and WC fittings, water taps Laufen Pro S, Laufen City Pro, glass shower partition walls ceramic 200x200 mm tiles SURFACE TREATMENT plaster stucco cement-lime plaster, paint repaired in 2017 ceilings gypsum board, paint; wooden truss elements, paint MEASUREMENT OF ENERGY CONSUMPTION drinking water water meter in unit, remote reading electricity unit electric meter in area of stairwell heat meter in unit, remote reading TERRACE floor, railing ceramic tiling on disks, steel railing on ledge fittings electrical outlet, lights, water pipe * The right to change materials, configuration and dates is reserved. Explanation of statuses: "" - Indicates the delivery or implementation of entirely new structures, elements, wiring, items, etc. as part of the structural modifications of the units and the common parts of the building. The guarantee pursuant to the relevant paragraph of the Purchase Agreement applied to the parts of the units with the designation of "new" with a specification of the year of implementation or acquisition. "original" - indicates the original condition of the specified structure, element, wiring, fittings of the unit, on which no repairs, modifications, or revisions have taken place, there have been no interventions on them of any kind and they can show deviations from current standards or norms.

6 "revision in 2017" - There was only a review on the system, wiring, device or equipment in question in the given year to guarantee its safe functionality. A guarantee pursuant to the relevant paragraph of the Purchase Agreement applies to these parts of the units with the "revision" designation. "repaired in 2017" - repairs guarnateeing the status after the performance of work necessary for the renewal/improvement of the appearance and primarily to ensure the correct functionality. The repairs take place in the form of local or full surface treatment, in the form of the adjustment, addition or exchange or some of the elements. During the repairs the functions or visual or other parameters corresponding to the status of "New" are never reached. Notes to the Technical Description / Standards (Description of selected structures, elements, materials, items and systems) Flat and Common parts of block of flats: Exterior doors and windows - due to external conditions (temperature changes, aging of construction, loading, etc.) there can be an imperceptible deviation of the windows, i.e. "slack", which is exhibited by abutting on the frame, a lack of sealing or difficulty in opening the window. In this case this is considered to be a frequent phenomenon, which is not caused by a product or assembly defect and thus cannot be claimed. In the event that such a phenomenon arises, it is necessary to ensure the adjustment of the window without great delay. The service is a matter of regular maintenance and is performed by the client at its own expense. The functional joints of the original windows may not seal completely, leading to a larger than usual amount of external air leaking into the interior. Interior and entrance doors - if there is "slack" in the doors, the situation and approach is the same as in the case of "Exterior doors and windows" (see above) - the adjustment of the door is provided by the client at its own expense. During the assembly of new doors on the original frames, the door may not sit well on the frame, leading to the more difficult closing or locking of the door. Floor treading layer - In the case of "New" this is only the delivery of floor coverings and not the complete implementation of the floor. Thus the contractor is only responsible for the quality of the assemby and the material of the treading layer. In the case of the original treading layer there may be some sag, some manifestations of noise (creaches, etc.) and/or the imperfect sealing of the joints of the individual flooring elements. Walls, ceilings - in light of the historical character of the building, it is necessary to expect deviations from the parameters prescribed by the current valid norms (ČSN). Primarily the flatness and verticality of the structure, the perpendicularity of the structural joints, etc. may not be maintained. Due to the load the original wooden load-bearing ceiling structures can be bent and can also lead to the uneveness of the floor's treading layer. Acoustics - the fulfilment of acoustic standards cannot be guaranteed for walls between flats and floor structures, the structure or the actual construction of which has not been altered, except for the treading layer. This applies primarily to the damping of impact noise and sound-transmission loss. The guarantee does not apply to the characteristics of the original dividing structures. Underground floors of the block of flats - in light of the historical character of the building and its technical design, it is necessary to point out the possibility of the permeation of moisture through the circumference wall and the floor. Balconies, terraces - for the original structures, where the exchange of the treading layers has not been performed, some places with an insufficient drainage of rain water can be expected. These phenomena are caused primarily by the poor weathered pointing of the horizontal structure. Façade - climatic phenomena (rain, changes of temperatures,...) can lead to the occurrence of microfissures and the disruption of the plaster, primarily in the places under the greatest strain, e.g. the plinths of the circumference wall. Connection of structures on the exterior of the building - Connecting two or more structures can, in time, lead to the creation of smaller or larger cracks in the connections/joints. This phenomenon is caused by the influence of different physical characteristics of the materials and changes in climatic conditions. The creation of joints usually has no effect on the technical characteristics or safety of the use of the building.

RODINNÉ DOMY STODŮLKY. Standards

RODINNÉ DOMY STODŮLKY. Standards RODINNÉ DOMY STODŮLKY Standards BUILDING Floors in residential rooms Entrance hall Kahrs Linnea 3-layer veneer floor, 3-parquet, finished with a moulding, a selection from natural oak and bleached oak

More information

Saraswathi. Floor Plans

Saraswathi. Floor Plans 1 / 15 Saraswathi Saraswathi is situated in a posh yet serene locality in Besant Nagar, a stone s throw away from Elliots Beach. The property covers 3 grounds and houses 8 apartments in a spacious 3 BHK

More information

The Alcalá Residential Development combines the peace and quiet of a residential area with the convenience of living in the city.

The Alcalá Residential Development combines the peace and quiet of a residential area with the convenience of living in the city. Your new life starts here In Parque Almunia, one of the areas in Granada with the most growth, Inmobiliaria Osuna is building a development for you that is unique in its specifications, amenities, location

More information

Residencial Ciudad Jardín - Edificio Magnolia c/ La campanilla,

Residencial Ciudad Jardín - Edificio Magnolia c/ La campanilla, Bet by Ciudad Jardín To delude it is easy. Now to fullfil your desires, also. Located in Ciudad Jardín, Magnolia Building reflects the expansion and the future of a city that advances. Bet by the maximum

More information

Residencial Las Américas - Edificio California C/ Sierra de Gredos,

Residencial Las Américas - Edificio California C/ Sierra de Gredos, Don t you think it s time to change your life? Then, bear this in mind! One more step in the creation of one of the best urban developent conceptions in Almería: Residencial Las Américas. Edificio Californi

More information

TABLE OF CONTENTS Public Safety Building

TABLE OF CONTENTS Public Safety Building DOCUMENT 00 01 10 - TABLE OF CONTENTS VOLUME I DIVISION 00 PROCUREMENT AND CONTRACTING REQUIREMENTS 00 01 10 Table of Contents 00 31 32 Geotechnical Data DIVISION 01 GENERAL REQUIREMENTS 01 10 00 Summary

More information

Franklin Hall Renovation TABLE OF Document Indiana University Bloomington

Franklin Hall Renovation TABLE OF Document Indiana University Bloomington VPS Project No. 2013022.00 Page 1 SPECIFICATIONS VOLUME I INTRODUCTORY INFORMATION Document 000010 - Table of Contents... 6 Document 000011 - Certification and Seals... 2 Document 000012 - Project Directory...

More information

Residencial Vila Park - "Viviendas desde *. Plaza y Trastero Incluido" Avda. Mestral s/n,

Residencial Vila Park - Viviendas desde *. Plaza y Trastero Incluido Avda. Mestral s/n, Experience the Mediterranean Inmobiliaria Osuna offers you a residential complex that matches your needs: Vila Park, where quality and comfort complement each other, hand in hand. Vila Park is a combination

More information

Edificio Puerto Príncipe Pza. de Las Américas,

Edificio Puerto Príncipe Pza. de Las Américas, Having you on board is a real privilege We were thinking of you when we designed the Puerto Príncipe building. Magnificent 3 and 4 bedroomed flats and top-floor flats with large terraces in a private complex

More information

GROUNDS Grading General Grading, slope and drainage: Satisfactory N/A See Notes. Grading and slope at house wall

GROUNDS Grading General Grading, slope and drainage: Satisfactory N/A See Notes. Grading and slope at house wall GROUNDS Grading General Grading, slope and drainage: Satisfactory Grading and slope at house wall Satisfactory (within 5 feet from building) Sidewalk Concrete Brick Flagstone Other Patio stones Driveway

More information

Residencial Estoril Camino de los Neveros,

Residencial Estoril Camino de los Neveros, Exclusive Areas Designed to meet the most demanding requirements, the most contemporary architecture merges with fine traditional elements at the Estoril Residential Development, creating an exclusive

More information

Via Parque Alicante BUILDING SPECIFICATIONS

Via Parque Alicante BUILDING SPECIFICATIONS WE BUILD YOUR HOUSE, SO YOU CAN MAKE IT A HOME Via Parque Alicante BUILDING SPECIFICATIONS f\ acciona Inmobiliaria First impressions do count 01. FAÇADE Facing brick façade to feature two colours, depending

More information

CE410. CE 410 Guidelines to Structural Design Drawings

CE410. CE 410 Guidelines to Structural Design Drawings CE 410 Guidelines to Structural Design Drawings As an essential part of your structural design projects all groups in CE 410 are going to develop their designs in reference to simplified architectural

More information

Quality specifications for my home

Quality specifications for my home Quality specifications for my home by 7 Benefits of a dospuntos home 2 Quality specifications Casa Banderas 01 02 Outside: Before you go in: Façades Your home will have a ceramic brick façade finished

More information

WALNUT CREEK - DETAILS OF TECHNICAL SPECIFICATIONS SPECS FOR VASWANI PORTION. 200 mm solid concrete blocks. Reinforced Cement Concrete - Flat Roof

WALNUT CREEK - DETAILS OF TECHNICAL SPECIFICATIONS SPECS FOR VASWANI PORTION. 200 mm solid concrete blocks. Reinforced Cement Concrete - Flat Roof WALNUT CREEK - DETAILS OF TECHNICAL SPECIFICATIONS DESCRIPTION BASIC STRUCTURE Foundation Super Structure Internal Walls External Walls Roof RCC footing Framed Structure 200 & 100 mm Solid Concrete Blocks

More information

INTERNATIONAL BUSINESS CENTRE. General Specifications for Common and Private Offices areas

INTERNATIONAL BUSINESS CENTRE. General Specifications for Common and Private Offices areas INTERNATIONAL BUSINS CENTRE General Specifications for Common and Private Offices areas KANIKA INTERNATIONAL BUSINS CENTRE GENERAL SPECIFICATIONS FOR COMMON AREAS 1. BUILDING STRUCTURE Concrete Structure:

More information

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT TABLE OF CONTENTS INTRODUCTORY INFORMATION 00 00 10 Title Page 00 00 20 Table of Contents DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT Section 00 02 00 Notice to Bidders

More information

Inclusions FRAMING GARAGE FIXED SITE COSTS & CONNECTIONS EXTERNAL. 90mm pine wall frames with stabilised pine roof trusses

Inclusions FRAMING GARAGE FIXED SITE COSTS & CONNECTIONS EXTERNAL. 90mm pine wall frames with stabilised pine roof trusses Inclusions FRAMING 90mm pine wall frames with stabilised pine roof trusses GARAGE Brick veneer garage including sectional overhead door to front (garage size product specific) Painted fibrous cement sheet

More information

3. Appliances - Free Standing x

3. Appliances - Free Standing x EXHIBIT "B" CARLSBAD CREST HOMES ASSOCIATION, INC. ASSOCIATION/ MAINTENANCE, REP AIR & REPLACEMENT MATRIX The following is a listing of the items within the Development, the maintenance, repair and replacement

More information

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT TABLE OF CONTENTS INTRODUCTORY INFORMATION 00 00 10 Title Page 00 00 20 Table of Contents DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT Section 00 02 00 Notice to Bidders

More information

PROCUREMENT AND CONTRACTING DOCUMENTS GROUP

PROCUREMENT AND CONTRACTING DOCUMENTS GROUP PROCUREMENT AND CONTRACTING DOCUMENTS GROUP DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS 00 11 00 Notice To Bidders 00 21 00 Instructions To Bidders 00 22 00 Supplementary Instructions To Bidders

More information

Waterfront. Floor Plans

Waterfront. Floor Plans Waterfront Spread over 4.33 acres and joined by an additional 4 acres of green belt, Waterfront is an exquisite upscale residential complex overlooking the lake at Kazhipattur Village with 115 high end

More information

QUALITY SPECIFICATIONS - List of materials and fittings

QUALITY SPECIFICATIONS - List of materials and fittings QUALITY SPECIFICATIONS - List of materials and fittings FOUNDATION AND STRUCTURE Foundation of reinforced concrete. Built with Expandable Polystyrene Panels encased in microconcrete with reinforced steel

More information

Building Systems and Design Elements included in SliDeRulE

Building Systems and Design Elements included in SliDeRulE Building Systems and Design Elements included in SliDeRulE No. System Subsystem Design Element 1.1.1 Foundation Deep Foundation Steel H-pile 1.1.2 Foundation Deep Foundation Steel pipe pile 1.1.3 Foundation

More information

SITE AND BUILDING INSPECTION CHECKLIST

SITE AND BUILDING INSPECTION CHECKLIST PARISH BUILDING Page 1 of 6 SITE AND GROUNDS DATE INIT COMMENTS DATE INIT COMMENTS Ramps & Provisions for Handicap Designated parking spaces for Handicap Has soil dropped or heaved Is there standing water

More information

ANNEX A.1 TECHNICAL SPECIFICATIONS. Open Call for Tender. No F/SE/10/05. Provision of Building Inspection, Maintenance, Alteration and Repair services

ANNEX A.1 TECHNICAL SPECIFICATIONS. Open Call for Tender. No F/SE/10/05. Provision of Building Inspection, Maintenance, Alteration and Repair services ANNEX A.1 TECHNICAL SPECIFICATIONS Open Call for Tender No F/SE/10/05 Provision of Building Inspection, Maintenance, Alteration and Repair services Building Inspection, Maintenance, Alteration and Repair

More information

EKATERINI COURT I 48 Kyriacou Matsi Avenue 2409 Egomi, Nicosia,Cyprus. EKATERINI COURT IV, Kantaras Avenue, Strovolos, Nicosia

EKATERINI COURT I 48 Kyriacou Matsi Avenue 2409 Egomi, Nicosia,Cyprus. EKATERINI COURT IV, Kantaras Avenue, Strovolos, Nicosia EKATERINI COURT I 48 Kyriacou Matsi Avenue 2409 Egomi, Nicosia,Cyprus EKATERINI COURT IV, Kantaras Avenue, Strovolos, Nicosia FOUNDATIONS & CONCRETE STRUCTURE Reinforced concrete based on an anti-seismic

More information

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent. SECTION 092900 - GYPSUM BOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

FOREST PLACE 59 UNITS ERF 5586 PARKLANDS

FOREST PLACE 59 UNITS ERF 5586 PARKLANDS ANNEXURE "C" MATERIAL AND FINISHES SPECIFICATION FOREST PLACE 59 UNITS ERF 5586 PARKLANDS 1. FOUNDATIONS AND STRUCTURE Foundation walls are to be built in strict accordance with the municipal building

More information

Appendix J - Custom Uniformat for EDU Migration

Appendix J - Custom Uniformat for EDU Migration Appendix J - Custom Uniformat for EDU Migration Nr. MTC Uniformat for VFA.facility Life (Years) Weight (1-100) Out of Scope Cost Y/N 1 A Substructure 150 N 2 A10 Foundations 150 N 3 A1010 Standard Foundations

More information

BRIEF DESCRIPTION. "L'HORLOGERIE" Rue de Genève FERNEY VOLTAIRE. COLLECTIVE BUILDING 19 apartments for sale

BRIEF DESCRIPTION. L'HORLOGERIE Rue de Genève FERNEY VOLTAIRE. COLLECTIVE BUILDING 19 apartments for sale BRIEF DESCRIPTION "L'HORLOGERIE" Rue de Genève 01 210 FERNEY VOLTAIRE COLLECTIVE BUILDING 19 apartments for sale A BBC (Low Consumption Building) residence. A project with high energy performance. PRESENTATION

More information

SPECIFICATIONS AMOI STELLENBOSCH STANDARD OPTION

SPECIFICATIONS AMOI STELLENBOSCH STANDARD OPTION SPECIFICATIONS AMOI STELLENBOSCH STANDARD OPTION Walls: Exterior: Interior: Roof: Facias: Rain water goods: Windows: Window sills: Door frames: Cement Maxi brick, plastered and painted with one plaster

More information

Customer Specification

Customer Specification Customer Specification Hamilton Gardens, Elgin Plots 55-59, 87, 201-223 & 260-305 Page 1 Walls External walls will be of timber frame construction with external leaf of render block-work, or feature timber

More information

MILT-Pro. Built-in units and control centres for halls

MILT-Pro. Built-in units and control centres for halls MILT-Pro Built-in units and control centres for halls Space The MILT-Pro built-in units provide its design solution offer a large range of applications in commercial, manufacturing and warehouse spaces.

More information

NEW MNIR DESIGN INTERNATIONAL OPEN DESIGN COMPETITION COST PLAN ANALYSIS MNIR REDEVELOPMENT ELEMENTAL COST PLAN

NEW MNIR DESIGN INTERNATIONAL OPEN DESIGN COMPETITION COST PLAN ANALYSIS MNIR REDEVELOPMENT ELEMENTAL COST PLAN NEW MNIR DESIGN INTERNATIONAL OPEN DESIGN COMPETITION COST PLAN ANALYSIS MNIR REDEVELOPMENT ELEMENTAL COST PLAN 1 SUBSTRUCTURE 4 278 780,63 Substructure 1 Item 2 SUPERSTRUCTURE 26 039 623,47 2A Frame 1

More information

BUILDING SPECIFICATIONS

BUILDING SPECIFICATIONS BUILDING SPECIFICATIONS FOUNDATION AND STRUCTURE Foundations using reinforced concrete slabs, according to the data of the geotechnical study, complying with building standard CTE-DB-SE-C. Concrete walls

More information

City of High Point Airport Overlay District Noise Level Reduction Design Standards

City of High Point Airport Overlay District Noise Level Reduction Design Standards City of High Point Airport Overlay District Noise Level Reduction Design Standards Part A. Residential Design Standards for Zone 3 I. NOISE LEVEL REDUCTION (NLR) REQUIREMENT FOR ZONE 3. The City of High

More information

TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS

TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS AIA General Conditions... GC-1 to GC-44 Amendments to General Conditions... AM-1 to AM-2 Supplements to General Conditions... SU-1 to SU-7 00200 Instructions To Bidders... 1 3 00201 Contractor s Bidding

More information

Chapter 4 Test. Directions: Write the correct letter on the blank before each question.

Chapter 4 Test. Directions: Write the correct letter on the blank before each question. Chapter 4 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe the impact of fire on common building materials. 1. Which of the following is the

More information

Foil Back Gypsum Board

Foil Back Gypsum Board BRAND 09 29 00/NGC Foil Back Gypsum Board brand Foil Back Gypsum Board consists of a fire-resistant gypsum core with a heavy, natural finish and 100-percent recycled paper on the face and a strong liner

More information

Schedule of Values Cruise Terminal 2 Expansion

Schedule of Values Cruise Terminal 2 Expansion Schedule of Values The Schedule of Values outlined below is intended to reflect the standard format that would be used in a Contractors Application for Payment. Values reflect materials and labor. General

More information

The House of Bahrain Press Heritage

The House of Bahrain Press Heritage Sustainable Development and Planning II, Vol. 2 1457 The House of Bahrain Press Heritage M. M. Sirriyeh Research and Development Directorate, Ministry of Municipalities and Agriculture Affairs, Manama,

More information

COMMON ERRORS DURING CONSTRUCTION OF NEW BUILDINGS AND EFFECT OF WORKMANSHIP

COMMON ERRORS DURING CONSTRUCTION OF NEW BUILDINGS AND EFFECT OF WORKMANSHIP Harmonization of European Sound Insulation Descriptors and Classification Standards Florence, December 14 th 2010 COMMON ERRORS DURING CONSTRUCTION OF NEW BUILDINGS AND EFFECT OF WORKMANSHIP Patrizio Fausti

More information

NATASA COURT, Kyriacou Matsi Av. & Kykkou Str., Ayios Dometios, Nicosia

NATASA COURT, Kyriacou Matsi Av. & Kykkou Str., Ayios Dometios, Nicosia EKATERINI COURT 48 Kyriacou Matsi Avenue Ριγένης 63Β 2409 Egomi, Nicosia,Cyprus 1010 Λευκωσία NATASA COURT, Kyriacou Matsi Av. & Kykkou Str., Ayios Dometios, Nicosia FOUNDATIONS & CONCRETE STRUCTURE Reinforced

More information

ADDENDUM 2 - JULY 14, 2015

ADDENDUM 2 - JULY 14, 2015 7/9/2015 The Professional(s) of Record above has signed for the following specification sections: DIVISION 1 GENERAL REQUIREMENTS Section 01 10 00 Summary of Work Section 01 25 00 Substitution Procedures

More information

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION Town of Hague Building Inspector: Dale Wagner Home #: 306-225-2265 Cell #: 306-241-4741 Fill all part of the permit application including the date and signature.

More information

FRANKLIN VILLAGE APARTMENTS Building I Franklin Street Morristown, NJ Block: 3901 Lots: 4,5,6

FRANKLIN VILLAGE APARTMENTS Building I Franklin Street Morristown, NJ Block: 3901 Lots: 4,5,6 PROJECT MANUAL for: FRANKLIN VILLAGE APARTMENTS Building I Morristown, NJ 07960 Block: 3901 Lots: 4,5,6 Owner: Atlantic Health Investment Corp. 200 American Road Morris Plains, NJ 07950 Architect NETTA

More information

Watercrest - Sand Hill - Columbia, SC TABLE OF CONTENTS PROCUREMENT AND CONTRACTING REQUIREMENTS

Watercrest - Sand Hill - Columbia, SC TABLE OF CONTENTS PROCUREMENT AND CONTRACTING REQUIREMENTS Watercrest - Sand Hill - Columbia, SC 00 0110-1 TABLE OF CONTENTS DIVISION 00 PROCUREMENT AND CONTRACTING REQUIREMENTS INTRODUCTORY INFORMATION Document 00 0101 Document 00 0110 Project Title Page CONTRACTING

More information

Southington, CT. Project Manager: Ann Micacci, REALTOR Ext WinterberryWoodsLiving.com

Southington, CT. Project Manager: Ann Micacci, REALTOR Ext WinterberryWoodsLiving.com Southington, CT Project Manager: Ann Micacci, REALTOR 203-272-1821 Ext. 327 WinterberryWoodsLiving.com 330 SOUTH MAIN STREET, CHESHIRE, CT 06410 PHONE: 203-272-1821 2620 WHITNEY AVENUE, HAMDEN, CT 06518

More information

Unit 8 Walls & Partition

Unit 8 Walls & Partition Unit 8 Walls & Partition 1 1 Learning Objectives Briefly explain the functions & functional requirements of walls Differentiate and compare between load bearing and non-load bearing walls Briefly describe

More information

Reliance House Investors Report. IR11 September 2018

Reliance House Investors Report. IR11 September 2018 Reliance House Investors Report IR11 September 2018 Extension & Conversion of Reliance House to Create 139 Luxury Apartments The 3 storey extension, refurbishment, adaptation and the sub-division works

More information

ECOCASITA PLUS63. Drawings. Outside elevation example. Ground floor plan example. Page 1 of 27

ECOCASITA PLUS63. Drawings. Outside elevation example. Ground floor plan example. Page 1 of 27 ECOCASITA PLUS63 Drawings Outside elevation example Ground floor plan example Page 1 of 27 House Shell: High quality, environmentally friendly and affordable house made from Skintong. Outside walls: Inner

More information

KEVIN BURNS BUILDING INSPECTIONS REGISTERED BUILDER PRE-PURCHASE VISUAL STRUCTURAL INSPECTION REPORT No. 822

KEVIN BURNS BUILDING INSPECTIONS REGISTERED BUILDER PRE-PURCHASE VISUAL STRUCTURAL INSPECTION REPORT No. 822 KEVIN BURNS BUILDING INSPECTIONS REGISTERED BUILDER 6163 PRE-PURCHASE VISUAL STRUCTURAL INSPECTION REPORT No. 822 CLIENT: Talavera PROPERTY ADDRESS: Mindarie DATE: 20 April 2017 TIME: 9.00am WEATHER: Fine

More information

Arts Center- Building needs

Arts Center- Building needs Arts Center- Building needs Built in 1928 Last renovated in 1986 Priority 1- fascia repair Loose, rotting and missing fascia needs to be replaced to prevent water intrusion. There are seven different pieces

More information

Customer Specification

Customer Specification Customer Specification Dubford, Bridge of Don Houses & self-contained apartments Plots 107-129, 136-140, 226-231, 802-810, 1505-1522, 1607-1610, 1616-1618, 1621-1624, 1707, 1711-1714, 1717 & 1907-1908

More information

Definition of Wall. A continuous, vertical structure Thin relatively to its length and height

Definition of Wall. A continuous, vertical structure Thin relatively to its length and height Walls & Partition Learning Objectives Briefly explain the functions & functional requirements of walls Differentiate and compare between load bearing and non-load bearing walls Briefly describe the characteristics,

More information

TABLE OF CONTENTS Updated 1/2014 SECTION TITLE DATE

TABLE OF CONTENTS Updated 1/2014 SECTION TITLE DATE TABLE OF CONTENTS SECTION TITLE DATE Division 00 Procurement and Contracting Requirements 000101... Project Title Page 000116... CAD Standards 001116... Invitation to Bid 002113... Instructions to Bidders

More information

Type D. Ver. Ver. 6'-11"x 4'-8" Maid. 7'-5"x 4'-0" 6'-6"x 4'-7" Toilet. Kitchen. 5'-0"x 8'-1" 9'-1" X 8'-1" Living 11'-11"x 16'-8" 10'-9"x 12'-6"

Type D. Ver. Ver. 6'-11x 4'-8 Maid. 7'-5x 4'-0 6'-6x 4'-7 Toilet. Kitchen. 5'-0x 8'-1 9'-1 X 8'-1 Living 11'-11x 16'-8 10'-9x 12'-6 R O A D O : 10 A S T y p i c a l F l o o r P l a n ( 2nd to 5th floor) Bed-2 14'-8"x 12'-0" 11'-3"x 12'-6" 9'-0"x 10'-4" 6'-11"x 5'-0" Bed-4 12'-6"x 9'-0" 12'-7"x 10'-1" 4'-6"x 11'-3" 12'-11" X 10'-9"

More information

BELL ASSOCIATES ARCHITECTURE PLANNING

BELL ASSOCIATES ARCHITECTURE PLANNING BELL ASSOCIATES ARCHITECTURE PLANNING Roger Bell dip. arch. tech. Bsc. CAD Rogerstown, Rush, Co. Dublin. Muchgrange, Greenore, Co. Louth E bellassociates@eircom.net T 01-8430267 T 042 938 3865 M 087 2371984

More information

CATAMARAN TOWER - 1 Seef Area Plot 19, 20

CATAMARAN TOWER - 1 Seef Area Plot 19, 20 STATUS REPORT NO 18 [As on September 30, 2017] This report is intended as a status report and covers only the activities completed till date, non-completed works and work-in-progress. A. Project Details

More information

ANNEXURE B SECTION 1

ANNEXURE B SECTION 1 ANNEXURE B SECTION 1 HOUSING SPECIFICATIONS 1. Houses 1.1. Roofs Material: Architect approved concrete tiles @ 17,5 degree pitch on SABS approved underlay Colour: As per Architects. 1.2. Rainwater goods

More information

STARRCO M O D U L A R O F F I C E S Y S T E M S S P A C E S O L U T I O N S F O R T O D A Y A N D T O M O R R O W

STARRCO M O D U L A R O F F I C E S Y S T E M S S P A C E S O L U T I O N S F O R T O D A Y A N D T O M O R R O W STARRCO M O D U L A R O F F I C E S Y S T E M S SPACE SOLUTIONS FOR TODAY W.W. Cannon, Inc. 2653 Brenner Dr. Dallas, TX 75220 Phone: 214-357-2846 Toll Free: 800-442-3061 Fax: 214-357-4576 www.wwcannon.com

More information

DIVISION 05 METALS Commissioning of Metals STRUCTURAL METAL FRAMING Structural Steel Framing

DIVISION 05 METALS Commissioning of Metals STRUCTURAL METAL FRAMING Structural Steel Framing DIVISION 05 METALS 05 00 00 METALS 05 01 00 Maintenance of Metals 05 01 10 Maintenance of Structural Metal Framing 05 10 20 Maintenance of Metal Joists 05 10 30 Maintenance of Metal Decking 05 10 40 Maintenance

More information

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6 DECEMBER, 2016 Page 1 of 6 1 GENERAL 1.01 RELATED SECTIONS.1 Section 01 33 00 - Submittal Procedures..2 Section 07 21 16 - Batt and Blanket Insulation..3 Section 07 92 10 - Sealants..4 Section 09 91 00

More information

Alabama Home Inspections

Alabama Home Inspections Cover Page Property Inspection Report 1000 Sample Dr., Sampletown USA Inspection prepared for: Report Sample Inspection Date: 1/21/2010 Time: 400pm Size: Approx. 2,200sf Weather: Cloudy 62 Inspector: Bobby

More information

RB Homes, Inc. 152 Witherspoon St. Princeton, NJ P: (609) / F: (609)

RB Homes, Inc. 152 Witherspoon St. Princeton, NJ P: (609) / F: (609) STANDARD SPECIFICATIONS FOR 505 EWING STREET PRINCETON, NEW JERSEY EXTERIOR Garage Doors: * One 16 x7 steel insulated, tan door. * Two garage openers, 1 keypad * Steel insulated with embossed panels with

More information

Invitation to Bid. RLS Construction Group requests your firm to submit a quotation on the following project:

Invitation to Bid. RLS Construction Group requests your firm to submit a quotation on the following project: RLS CONSTRUCTION GROUP Phone: 717-502-6680 Fax: 717-502-6681 www.rlscg.com Invitation to Bid RLS Construction Group requests your firm to submit a quotation on the following project: Project: Location:

More information

TABLE OF CONTENTS. Calgary School District No. 19 March Page. Executive Summary. Facility Profile and Summary 1. Section 1 Site Conditions 4

TABLE OF CONTENTS. Calgary School District No. 19 March Page. Executive Summary. Facility Profile and Summary 1. Section 1 Site Conditions 4 TABLE OF CONTENTS Executive Summary Page i Facility Profile and Summary 1 Section 1 Site Conditions 4 Section 2 Building Exterior 7 Section 3 Building Interior 11 Section 4 Mechanical Systems 14 Section

More information

SureHome Inspection Company. Home Inspection. Grant st Street Omaha, NE 68048

SureHome Inspection Company. Home Inspection. Grant st Street Omaha, NE 68048 Home Inspection Grant 7142 21st Street Omaha, NE 68048 Page 1 of 13 Table of Contents Definitions 2 General Information 2 Roof 3 Exterior 4 Grounds 5 Attic 5 Garage 6 Bathroom 6 Interior 7 Kitchen 7 Laundry

More information

4.1.3 Project Manual

4.1.3 Project Manual 4.1.3 Project Manual (*Section requires Filed Sub-Bid) PROCUREMENT AND CONTRACTING REQUIREMENTS GROUP Division 00 Procurement and Contracting Requirements Section 00 01 03 Project Directory Section 01

More information

The Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits

The Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits The Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits 3. Development and Septic Fees 4. Tarion New Home Warranty

More information

Exhibition sectors at BAU

Exhibition sectors at BAU Exhibition sectors at BAU SAVE THE DATE BAU 2019 features materials, technology and systems for commercial and residential construction and interior work for both new-build and modernization and renovation

More information

RB Homes, Inc. 152 Witherspoon St. Princeton, NJ P: (609) / F: (609)

RB Homes, Inc. 152 Witherspoon St. Princeton, NJ P: (609) / F: (609) STANDARD SPECIFICATIONS FOR 73 LEAVITT LANE PRINCETON, NEW JERSEY EXTERIOR Garage Doors: * One 16 x7 steel insulated, tan door. * Two garage openers, 1 keypad. * Steel insulated with embossed panels with

More information

PND Training Hall Conex Building, Kabul ABSTRACT OF COST

PND Training Hall Conex Building, Kabul ABSTRACT OF COST PND Training Hall Conex Building, Kabul ABSTRACT OF COST A Civil Works All work items shall be carried as per drawing, specification and instruction of the Engineer. 1 Sub-structure Works Earthwork in

More information

WEST COAST EXTERIORS GOURMET KITCHENS RELIABLE SECURITY ELEGANT ENSUITES & BATHROOMS SOPHIARESIDENCES.CA

WEST COAST EXTERIORS GOURMET KITCHENS RELIABLE SECURITY ELEGANT ENSUITES & BATHROOMS SOPHIARESIDENCES.CA AFFORDABLE LUXURY & LASTING QUALITY Bold use of West Coast exterior materials, including Western Red Cedar siding; painted, corrugated metal panels; cementitious composite sheathing; and smooth acrylic

More information

SERIES 0 BIDDING REQUIREMENTS AND CONTRACT FORMS

SERIES 0 BIDDING REQUIREMENTS AND CONTRACT FORMS SERIES 0 BIDDING REQUIREMENTS AND CONTRACT FORMS INDIANA UNIVERSITY BIDDING REQUIREMENTS NOTICE TO BIDDERS BID FORM INSTRUCTIONS TO BIDDERS CONTRACTOR S BID FOR PUBLIC WORK - FORM 96 (REVISED 2005) MINORITY,

More information

THE BEST INCLUSIONS ALTI 202

THE BEST INCLUSIONS ALTI 202 THE BEST INCLUSIONS ALTI 202 WHITE LABEL RANGE WHITE LABEL INCLUSIONS PRELIMINARY WORKS Site Survey, soil test, site inspections as required Building Permit application including applicable fee Full set

More information

Gramercy Place Condo Association, Inc.

Gramercy Place Condo Association, Inc. E-Mail to fiona@ymginc.com Print Document Gramercy Place Condo Association, Inc. UNIT MODIFICATION REQUEST Date of Application: Name of Owner (s): Telephone: (Home) ````````````````````````` (Cell) E-Mail

More information

Cheshire, CT. By: A.M. Napolitano, LLC. Project Manager: Carolyne Sakonchick Ext. 323

Cheshire, CT. By: A.M. Napolitano, LLC. Project Manager: Carolyne Sakonchick Ext. 323 Cheshire, CT By: A.M. Napolitano, LLC Project Manager: Carolyne Sakonchick 203-272-1821 Ext. 323 Country Club Acres, Two beautiful homes, to be built on one acre lots, with city water/sewer. Meet the builders

More information

Wallingford, CT. Project Manager: Karen Charest Ext. 233

Wallingford, CT. Project Manager: Karen Charest Ext. 233 Wallingford, CT Project Manager: Karen Charest 203-265-1821 Ext. 233 THE MARTHA 1 MODEL at Simpson Village Martha 1 Model Total The rendering and floor plans substantially represent the model depicted.

More information

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ 08014 856-467-3626--- FAX 856-467-9260 Application for Certificate of Occupancy for Change of Occupancy Pursuant to Chapter 119 of the Township

More information

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free / / Paperport 2000 official estimating report Work Write Up / Specification of Repairs Toll Free 1-877-932-7177 Clients Name. GREAT CLIENT Property Address. NUMBER ONE GOOD ROAD METRO, VA 20000 Primary

More information

FOLDING CONTAINER HOUSE: AMH-4000 SERIES GENERAL AMH-4120 DIMENSIONS AND WEIGHT PICTURES:

FOLDING CONTAINER HOUSE: AMH-4000 SERIES GENERAL AMH-4120 DIMENSIONS AND WEIGHT PICTURES: FOLDING CONTAINER HOUSE: AMH-4000 SERIES GENERAL 1. The standard container for various purposes is suitable for international container transport. It is of appropriate external dimensions and has connections

More information

component was performing its intended function; installation and condition were appropriate for age and use.

component was performing its intended function; installation and condition were appropriate for age and use. April 23, 2012 Dear Home Seller, On April 6, 2012, Cities Inspection Service, Inc. completed a home inspection of the property located at 123 Oak Drive, Somewhere, Minnesota for you. Doug Hastings did

More information

The name RedRock was inspired from the colossal red rocks that are located on site. Red Maple trees with their brilliant red foliage: the highlight

The name RedRock was inspired from the colossal red rocks that are located on site. Red Maple trees with their brilliant red foliage: the highlight FLAGSHIP PROJECT BY The name RedRock was inspired from the colossal red rocks that are located on site. Red Maple trees with their brilliant red foliage: the highlight of his gorgeous scenery. Master

More information

Existing Site Aerial Frederick High School Feasibility Study September 5, 2012

Existing Site Aerial Frederick High School Feasibility Study September 5, 2012 Existing Site Aerial Building Developmental History 1981 1966 1939 1977 1978 1955 1966 Exterior Roof: Most of existing roof has multi ply built up roofing. Some areas have gravel ballast, others have cap

More information

LOOSE FILL ASBESTOS INSULATION

LOOSE FILL ASBESTOS INSULATION The following cards show how some common asbestos-containing materials can look. For more examples visit www.hse.gov.uk/asbestos-gallery LOOSE FILL ASBESTOS INSULATION Found in wall and floor cavities

More information

SPECIFICATION AND FINISHING SCHEDULE

SPECIFICATION AND FINISHING SCHEDULE SPECIFICATION AND FINISHING SCHEDULE 1. PURPOSE OF SPECIFICATION AND FINISHING SCHEDULE... 2 2. SPECIFICATION PRELIMINARIES... 2 3. SPECIFICATIONS... 3 3.1. Siteworks And Excavations... 3 3.2. Availability

More information

Helpsheet 35. Repairs response times. The following is a list of response times for different types of repairs.

Helpsheet 35. Repairs response times. The following is a list of response times for different types of repairs. Helpsheet 35 Repairs response times The following is a list of response times for different types of repairs. Please be aware that any list will miss out some possible repairs. In allocating priorities

More information

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM Form 15 Work Write-Up Owner-Builder Applicant Owner-Builder Co-Applicant Physical Address: City,

More information

Airport Vicinity Acoustic Insulation

Airport Vicinity Acoustic Insulation PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Airport Vicinity Acoustic Insulation By-law No. 6419/94 of the City of Winnipeg to establish minimum acoustic insulation requirements for buildings within

More information

ORDER OF AN EXECUTIVE OFFICER UNFIT FOR HUMAN HABITATION ORDER TO VACATE

ORDER OF AN EXECUTIVE OFFICER UNFIT FOR HUMAN HABITATION ORDER TO VACATE Environmental Public Health ORDER OF AN EXECUTIVE OFFICER UNFIT FOR HUMAN HABITATION ORDER TO VACATE To: And To: RE: Sugin Ao and Kui Zhong Lu the owners All Occupant(s) of the following Housing premises:

More information

The following is a list of response times for different types of repairs.

The following is a list of response times for different types of repairs. Helpsheet 35 Repairs response times The following is a list of response times for different types of repairs. Please be aware that any list will miss out some possible repairs. In allocating priorities

More information

Town of Enfield. Parks & Recreation P.O. Box 699 Enfield NC (252) telephone (252) fax

Town of Enfield. Parks & Recreation P.O. Box 699 Enfield NC (252) telephone (252) fax Town of Enfield Parks & Recreation P.O. Box 699 Enfield NC 27823 (252) 445-3146-telephone (252) 445-1019-fax www.enfieldnc.org Request for Proposals for the Renovation and/or Construction of the Recreation

More information

COMPANY: CERTIFIED HOME INSPECTIONS ADDRESS: 92 NORTH RD. CITY, STATE, ZIP: NUTLEY NJ PHONE:

COMPANY: CERTIFIED HOME INSPECTIONS ADDRESS: 92 NORTH RD. CITY, STATE, ZIP: NUTLEY NJ PHONE: COMPANY: CERTIFIED HOME INSPECTIONS ADDRESS: 92 NORTH RD. CITY, STATE, ZIP: NUTLEY NJ 07110 PHONE: 973-667-3747 New Jersey Home Inspector-Standards of Practice - NJ ADC 13:40-15.16 (a) All home inspectors

More information

Customer Specification

Customer Specification Customer Specification Hamilton Gardens, Elgin Plots 60-62 Page 1 Walls Timber frame construction with external leaf of render block-work. Timber studs with insulation and plasterboard finish internally.

More information

COPYRIGHTED MATERIAL. Contents. 1 Making Buildings 3. 3 Wood Foundations and. Preface to the Sixth Edition xi. Sitework 31

COPYRIGHTED MATERIAL. Contents. 1 Making Buildings 3. 3 Wood Foundations and. Preface to the Sixth Edition xi. Sitework 31 Contents Preface to the Sixth Edition xi 1 Making Buildings 3 Learning to Build 4 Buildings and the Environment 5 The Work of the Design Professional 11 The Work of the Construction Professional 19 Trends

More information

DESIGN & CONSTRUCTION GUIDELINES

DESIGN & CONSTRUCTION GUIDELINES DESIGN & CONSTRUCTION GUIDELINES EDITION: USF FACILITIES MANAGEMENT - DC 5 DCG FACILITIES MANAGEMENT DESIGN & CONSTRUCTION PHONE: (813) 974-2845 4202 E. FOWLER AVENUE, OPM 1000 TAMPA, FLORIDA 33620-7550

More information