1 STYLE. QUALITY. FUNCTIONALITY Technical catalog of ARPANEL sandwich panels Edition III

2 Production line of ARPANEL sandwich panels

3 Table of contents 1. Introduction 4 2. ARPANEL sandwich panels system A structure of ARPANEL sandwich panels Types of ARPANEL sandwich panels Jointing of sandwich panels and fastening them to the structure Environment and conditions for application of the ARPANEL Profiling of claddings Colors Technical parameters Scope of application of the ARPANEL sandwich panels Thermal insulation Reaction to the fire and fire resistance parameters Acoustic parameters of the ARPANEL sandwich panels Technical details - exemplary solutions Horizontal facade system Vertical facade system Panel roofing system Panel walls system for cooling rooms Resistance tables Transport instructions Basic information on installation of ARPANEL sandwich panels Product guarantee for the ARPANEL sandwich panels with standard cladding Declarations Hygienic certificates 127 Adamietz Sp. z o.o., the manufacturer od the ARPANEL sandwich panels bears no liability for any potential differences between factual parameters and the contents of this catalogue. The manufacturer reserves the right to amend this work without prior notice. 3

4 1. Introduction Adamietz company was established in Since then, we have been continuously improving our competences in operating in the building construction area. The experience obtained on international markets allows us to meet high expectations of our clients. Our company has been at disposal of modern production halls, warehouses and offices of combined surface area reaching 19 km 2 since We act with highest efficiency practically within all fields related to the branch of professional construction services. We are well aware that flexibility and the time of reaction is what differentiates us from the competition. Our field of specialization encompasses realization of various industrial objects, public utility buildings, warehouses, car showrooms or sport and recreational halls, e.g. swimming pools, aquaparks or SPA centers. All our attention is focused on products that meet the highest requirements of our client: investors, designers and users of contemporary industrial, commercial and public utility objects. Bearing in mind our recipients, we started production of insulation sandwich panels in 2013, for construction of roofs and walls of various objects with steel and reinforced concrete structures. The production process was preceded by 3 years of intensive preparations. At that time, we developed and implemented a technology, which allowed to start one of the most modern assembly lines in Europe, producing sandwich panels. We based the technology of ours on experiences of European leaders, specialized in providing technologies for the high-end insulation materials production. This is how the ARPANEL system was developed. ARPANEL is a system that combines current trends in construction and design with expertise and longstanding knowledge of our team. It is a work of the highest class experts. These are not only the sandwich panels. ARPANEL is a complex system, which is a result of our more than 20 years long experience in designing and realizing light panels, additionally supported with deep analysis of European markets and expectations of contemporary recipients. The ARPANEL sandwich panels have been designed with three insulation cores: polyurethane foam PUR, polyisocyanurate foam PIR, MiWo mineral wool. Variety of the ARPANEL offer is appreciated by investors, designers and contractors, who therefore have the freedom to choose a proper solution in roof and walls insulation, regarding their needs as well as the kind and purpose of the object. ARPANEL means style, quality and functionality. 4

5 2. ARPANEL sandwich panels system 5 ARPANEL sandwich panels system

6 2.1 A structure of ARPANEL sandwich panels The APANEL sandwich panels are prefabricated elements composed of two pieces of cladding manufactured from steel sheet (external and internal) and a constructioninsulation core, which is located between them and prepared from rigid polyurethane or polyisocyanurate foam. Core of the panel provides thermal and acoustic insulation. The steel claddings are secured against corrosion, and together with the core, they provide the plate with high mechanical resistance. Claddings of the ARPANEL sandwich panels are manufactured from galvanized steel sheet on both sides, from 0.4 to 0.7 mm thick, covered with organic protective layers, which provide resistance towards factors with various levels of aggressiveness. The sheet cladding in a standard version is covered with a layer of polyester, however in conditions that require a higher level of resistance to corrosion, or when the sandwich layers have contact with food, the sheet may be covered with a layer of PCV, HPS 200, PVDF or HPS prisma. Metal layers of the ARPANEL panel play not only protect from the weather conditions, such as rain or snow, but they also have decorative functions. What is significant is the fact that while having contact with steam, humidity, snow or chemical substances, they fully preserve their qualities. Structural scheme of exemplary ARPANEL sandwich panels The ARPANEL sandwich panels have been designed with three insulation cores, namely: PUR - i.e. a mixture of polyols with foaming qualities, i.e. From polyurethane foam PUR characterized with high insulation parameters and density of about 40 +/- 3 [kg/m 3 ], pursuant to the PN-EN standard; PIR - from polyisocyanurate foam with a chemically modified polyurethane core, which while preserving proper mechanical and thermal-insulation qualities, is characterized with an elevated fire resistance level; MiWo - hard, inflammable rock mineral wool with thickness of 105 [kg/m 3 ] and the arrangement of fibers perpendicular to linings, characterized with a high fire resistance, incomparably higher than the remaining types of the sandwich panels cores. The wool applied in production of the panels is mineral wool consisting of basalt fibers of very high rigidity and mechanical resistance. The main task of the core is to provide acoustic and thermal insulation. The steel claddings, together with core, play a role of a partition protecting against wind, temperature, fire, snow weight and other numerous weather conditions. Wall and roof ARPANEL sandwich panels in steel claddings are a construction material most often applied for construction of industrial, commercial, cubature, office, sport and agricultural buildings, as well as public utility objects. The ARPANEL sandwich panels are applied in various objects, also in construction of partition walls, ceilings and remaining walls. 1. Filling from polyurethane PUR/PIR foam 2. PUR seal, 6 mm thick, installed during the production process 3. Steel claddings 4. Filling from MiWo mineral wool 5. Steel claddings ARPANEL S PUR/PIR polyurethane core panel ARPANEL S MiWo mineral wool core panel external side external side internal side internal side 6 ARPANEL sandwich panels system

7 2.2 Types of ARPANEL sandwich panels Development of industry and competition, together with an increase in ecological requirements pertaining to construction objects, forces investors to apply the most modern construction materials at realization of their investments. Therefore, the claddings in the ARPANEL sandwich panels are characterized with the highest quality. They are prepared from galvanized steel sheets coated with an organic layer, e.g. polyester, which is to provide proper rigidity and bearing capacity, as well as to protect the insulation core. Parameters of the steel claddings are adjusted to requirements of the design very time, and the wide array of colors allows to obtain an extraordinary character of the facade. The experienced ARPANEL team is focused on realization of investment tasks, where apart from economics and energetic efficiency, also style, quality and functionally matter. Numerous investors, who used our company s offer, are already aware of this. The ARPANEL sandwich panels, filled with PUR/PIR and MiWo foam, pose an element of the cutting-edge system of light envelope construction of objects, characterized with perfect technical parameters, which meets the latest technical and ecological requirements, and in case of the panels with PIR core, is characterized with increased resistance against fire. The ARPANEL offer covers not only the sandwich panels. Adamietz company also specializes in complex realization of industrial objects. Our group of companies encompasses, among others, a factory of cold-rolled profiles (including flashings), and of steel structures. Thanks to the strategy of offering complex solutions for industrial construction, adopted at the very beginning, our company, apart from the sandwich panels, provides a wide array of assembling accessories. We believe that only a complex offer provides our customers with all elements necessary for preparation of modern and tight walls and roofs. ARPANEL offer the following sandwich panels: ARPANEL S PUR/PIR wall sandwich panel - a standard fastening system; ARPANEL SU PUR/PIR wall sandwich panel - a hidden fastening system; ARPANEL D PUR/PIR roof sandwich panel; ARPANEL CH PUR/PIR cooling room sandwich panel ARPANEL S MiWo wall sandwich panel - a standard fastening system. 7 ARPANEL sandwich panels system

8 2.2 Types of ARPANEL sandwich panels ARPANEL S PUR/PIR wall sandwich panel - a standard fastening system Fixing screw Steel claddings PUR/PIR core panel width: 1000, 1100, 1150 mm D D = 40, 60, 80, 100 mm 8 ARPANEL sandwich panels system

9 2.2 Types of ARPANEL sandwich panels ARPANEL SU PUR/PIR wall sandwich panel - a hidden fastening system Fixing screw Steel claddings Fastening plate element PUR/PIR core panel width: 1000 mm D D = 60, 80, 100, 120 mm 9 ARPANEL sandwich panels system

10 2.2 Types of ARPANEL sandwich panels ARPANEL D PUR/PIR roof sandwich panel Fixing screw Calotte Steel claddings PUR/PIR core panel width: 1000 mm D D = 40, 60, 80, 100, 120 mm 10 ARPANEL sandwich panels system

11 2.2 Types of ARPANEL sandwich panels ARPANEL CH PUR/PIR cooling room sandwich panel Fixing screw Steel claddings PUR/PIR core panel width: 1000, 1100, 1150 mm D D = 120, 160, 200 mm 11 ARPANEL sandwich panels system

12 2.2 Types of ARPANEL sandwich panels ARPANEL S MiWo wall sandwich panel - a standard fastening system Fixing screw Steel claddings Mineral wool core panel with: 1000, 1100, 1150 D D = 80, 100, 120, 150, 180, 200, 220* mm * Thickness of 220 mm is produced on special order after consultation with the manufacturer 12 ARPANEL sandwich panels system

13 2.3 Jointing of sandwich panels and fastening them to the structure Jointing of ARPANEL S PUR/PIR sandwich panels a standard fastening system seal 4,0 mm sealing tape 3 Jointing of ARPANEL S PUR/PIR sandwich panels - a hidden fastening system fastening pad/ pressure separator Fastening washer/ pressure separator , , ,5 sealing tape ,8 ARPANEL D PUR/PIR sandwich panels jointing ~ 300 sealing tape 13 ARPANEL sandwich panels system

14 2.3 Jointing of sandwich panels and fastening them to the structure Jointing of ARPANEL CH PUR/PIR cooling room sandwich panels sealing tape Jointing of ARPANEL S PUR/PIR sandwich panels - a hidden fastening system ARPANEL sandwich panels system

15 2.4 Environment and conditions for application of the ARPANEL It is crucial to specify the environment, where the panel will be applied, while selecting the desired parameters of the sandwich panels. It is necessary to properly recognize and determine the aggressiveness class of both external (from C2 to C5-M) and internal (from A1 to A6) working environment. All PE 25 coating can be applied for all so called neutral environments, when it comes to locations such as e.g. meat, fish processing plants or fertilizers factories, the designer, after consultations with the user, informs about environmental conditions, which allow to choose proper coatings by the manufacturer of sandwich panels. The table below specifies codification of the environment for ARPANEL sandwich panels together with their localization. Type of corrosion protection SP SP PVDF PVDF+ PUR PVC(P) PVC+F Anti-corrosion classification [DIN ] II III III III III III III Total organic thickness [EN ] Category of resistance to corrosion ** Outside - EN RC3 RC3 RC4 RC5 RC5 - Inside - EN CPI2 CPI3 CPI3 CPI4 CPI5 CPI4 CPI5 Types of internal atmosphere / corrosiveness category EN Rural - standard C2 - *** - Urban and industrial C3 & C4 - *** - 0 < 10 km from the sea C5 - M - - *** - Sea 10 < 20 km from the sea C4 - *** - Heavy industry C5 - I *** - Non-corrosive atmosphere Routine conservation - standard Low humidity Ai1-40 C 25 C 0% - 40%* Type of internal atmosphere / corrosiveness category EN Non-corrosive atmosphere Routine conservation - standard Average humidity Non-corrosive atmosphere Delicate cleaning High humidity Slightly corrosive atmosphere Delicate cleaning Humid (condensation risk) Corrosive atmosphere Intensive cleaning Very humid (high condensation risk) Ai2 0 C 25 C 40% - 60%* Ai3 0 C 25 C 60% - 80%* Ai4 0 C 30 C 60% - 80%* Ai5 0 C 35 C 80% - 90%* Strongly corrosive atmosphere Very intensive cleaning Saturated (continuous condensation risk) Ai6 0 C 40 C 90% - 100%* Temperature resistance ( C) UV (ultraviolet light) resistance category - EN Ruv3 Ruv4 Ruv4 Ruv4 Ruv2 - Flexibility Staining resistance good with exceptions good very good very good with no exceptions - unsuitable * During cleaning, the temperature cannot drop below the condensation point. The detailed information is provided in the table: temperature of the condensation point pertains to particular ambient temperature and relative humidity. In case of cooling, the working temperature needs to remain on the level of 3 C above the condensation point. ** The categories of corrosiveness depend on climate conditions inside and outside the building. Standard external climatic conditions: C1, C2, C3, C4, C5-M i C5-1. Example: C3 external atmosphere - you need to choose steel sheet with RCS or RC4 level of corrosiveness *** Recommended for use 48th parallel north, in the maximal temperature of 70 C 15 ARPANEL sandwich panels system

16 2.5 Profiling of claddings external surface D internal surface Profiling Linear Mikro 14 Mikro 8 Plain External surface TAK TAK TAK TAK Internal surface TAK NIE NIE TAK Linear Linear 14 Mikro 14 Mikro 14 8 Mikro 8 Mikro 8 Plain Roof profile (regarding PUR/PIR panels) Trapezoidal Trapezoidal 16 ARPANEL sandwich panels system

17 2.6 Colors Colors of the ARPANEL sandwich panels are determined in accordance with the RAL color standard. Other colors are available on special request The ARPANEL sandwich panels are manufactured with internal and external claddings, in standard basic colors. If the customer is interested in other colors, it is possible to agree on conditions of the delivery by contacting the ARPANE Customer Service Center, and verifying availability of the color within the market of sheets manufacturers. It is recommended, pursuant to the tables and regardless the choice of panels, to have the sandwich panels in dark color installed only in single-span arrangements. Application of multi-span arrangements may cause the intermediate support to present delicate ripples resulting from higher thermal loads. These ripples are formally permitted by the product standard, however the investor may have some aesthetic reservations, and as a result lodge a complaint. In case of multi-span arrangements, which include panels in dark colors, we do not guarantee plainness of the surface, unless it was agreed with a representative of our company beforehand. However, such an agreement requires a written form. Division into color groups RAL 1015, 1016, 1018, 6019, 7035, 9001, Group 1 - very light colors 9002, 9010 RAL 1002, 1003, 1004, 1014, 1017, 1019, 1021, 1023, 1035, 2000, 2003, 2004, 2008, 2009, Group 2 - light colors 5012, 5024, 6018, 6021, 6033, 7000, 7037, 7040, 9006, 9022 RAL 3000, 3002, 3003, 3005, 3011, 3013, 5002, 5005, 5009, 5010, 5011, 5022, 6000, 6003, Group 3 - dark colors 6005, 6011, 6020, 6029, 7015, 7016, 7022, 7024, 8016,8017, 8023, 9005, 9007 General characteristics of RAL colors RAL - a system of matching colors, based on comparison with templates. This is the manner of determining color of paints for metal, car aerosol lacquers, self-adhering PVC foils used by artists, and in numerous other cases, also of paints mixed by a computer, regardless their manufacturer. The name RAL is an abbreviation of the name of a German institution established in 1920s: Reichsausschuss für Lieferbedingungen. It has been named the German Institute of Quality Assurance and RAL certification (Deutsches Institut für Gütesicherung und Kennzeichnung e.v.) One of the tasks of this institute is to systematize description of colors for industrial and commercial applications. For 75 years, responsibility for the quality of reflecting colors in the templates was borne by a single company, dealing with their production - Muster-Schmidt - established in Berlin in The system was created in 1927 and it originally included 30 colors. Currently, more than 200 are systematized. The system does not correspond with other color models. The colors are determined arbitrary. To differentiate it from other, complex systems of matching colors, it was called RAL CLASSIC. The matching is composed of the term RAL and four digits: RAL 10xx yellow hues, RAL 20xx orange hues, RAL 30xx red and pink hues, RAL 40xx purple and violet hues, RAL 50xx blue hues, RAL 60xx green hues, RAL 70xx grey hues, RAL 80xx brown hues, RAL 90xx white and black hues. Additionally, a more accurate model was created, called RAL DESIGN, which encompasses 1625 colors, and systematizes them regarding the experimentally measured lightness and saturation. NOTE: A table of exemplary RAL colors applied for claddings of sandwich panels can be found on the last page, internal side of the Colors in the RAL DESIGN system are noted with a numerical code, which is composed of a term RAL and seven digits, e.g.: RAL where 210 means the hue, 60 lightness and 30 chroma, which is illustrated in location in space within the CIE LCH hues. (acc. to RALCOL). 17 ARPANEL sandwich panels system

18 2.7 Technical parameters Panel type Panel marking Core thickness Core density Module width Weight Grupa nazwa mm kg/m 3 mm kg/m 2 ARPANEL S / , 1100, ,90 ARPANEL S PUR/PIR wall sandwich panel - a standard fastening ARPANEL S / , 1100, ,70 ARPANEL S / , 1100, ,50 ARPANEL S / , 1100, ,30 ARPANEL SU / ,70 ARPANEL SU PUR/PIR wall sandwich panel - a hidden fastening system ARPANEL SU / ,50 ARPANEL SU / ,30 ARPANEL SU / ,50 ARPANEL D 40/ / ,20 ARPANEL D 60/ / ,00 ARPANEL D PUR/PIR roof sandwich panel ARPANEL D 80/ / ,80 ARPANEL D 100/ / ,60 ARPANEL D 120/ / ,40 ARPANEL CH PUR/PIR Cooling room sandwich panel ARPANEL CH / , 1100, ,10 ARPANEL CH / , 1100, ,70 ARPANEL CH / , 1100, ,30 ARPANEL S MiWo / , 1100, ,6 ARPANEL S MiWo / , 1100, ARPANEL S MiWo wall sandwich panel - a standard fastening system ARPANEL S MiWo / , 1100, ARPANEL S MiWo / , 1100, ,2 ARPANEL S MiWo / , 1100, ,1 ARPANEL S MiWo / , 1100, ,5 ARPANEL S MiWo * 105+/ , 1100, ,5 * Thickness of 220 mm is produced on special order after consultation with the manufacturer 18 ARPANEL sandwich panels system

19 2.7 Technical parameters Production lengths Internal standard color External standard color Metal layer standard Steel panels type m RAL RAL mm/mm Group 2,00-18, , , 9010, 9006, 9007, 7016, 7035, ,50 / 0,50 2,00-18, , ,00-18, , , 9010, 9006, 9007, 7016, 7035, , 9010, 9006, 9007, 7016, 7035, ,50 / 0,50 0,50 / 0,50 ARPANEL S PUR/PIR wall sandwich panel - a standard fastening 2,00-18, , , 9010, 9006, 9007, 7016, 7035, ,50 / 0,50 2,00-18, , , 9010, 9006, 9007, 7016, 7035, ,50 / 0,50 2,00-18, , ,00-18, , , 9010, 9006, 9007, 7016, 7035, , 9010, 9006, 9007, 7016, 7035, ,50 / 0,50 0,50 / 0,50 ARPANEL SU PUR/PIR wall sandwich panel - a hidden fastening system 2,00-18, , , 9010, 9006, 9007, 7016, 7035, ,50 / 0,50 2,00-18, , , 9010, 9006, 9007, 7016, 7035, ,50 / 0,50 2,00-18, , , 9010, 9006, 9007, 7016, 7035, ,50 / 0,50 2,00-18, , , 9010, 9006, 9007, 7016, 7035, ,50 / 0,50 ARPANEL D PUR/PIR roof sandwich panel 2,00-18, , , 9010, 9006, 9007, 7016, 7035, ,50 / 0,50 2,00-18, , , 9010, 9006, 9007, 7016, 7035, ,50 / 0,50 2,00-18, , ,00-18, , ,00-18, , , 9010, 9006, 9007, 7016, 7035, , 9010, 9006, 9007, 7016, 7035, , 9010, 9006, 9007, 7016, 7035, ,50 / 0,50 0,50 / 0,50 0,50 / 0,50 ARPANEL CH PUR/PIR Cooling room sandwich panel 2,00-14, , , 9010, 9006, 9007, 7016, 7035, ,60 / 0,50 2,00-14, , , 9010, 9006, 9007, 7016, 7035, ,60 / 0,50 2,00-14, , , 9010, 9006, 9007, 7016, 7035, ,60 / 0,50 2,00-14, , ,00-14, , , 9010, 9006, 9007, 7016, 7035, , 9010, 9006, 9007, 7016, 7035, ,60 / 0,50 0,60 / 0,50 ARPANEL S MiWo wall sandwich panel - a standard fastening system 2,00-14, , , 9010, 9006, 9007, 7016, 7035, ,60 / 0,50 2,00-14, , , 9010, 9006, 9007, 7016, 7035, ,60 / 0,50 19 ARPANEL sandwich panels system

20 2.8 Scope of application of the ARPANEL sandwich panels In contemporary construction industry, the ARPANEL sandwich panels pose perfect covering for walls and roofs. They are ready-made and comprehensive material for modern architecture and cutting-edge technologies. Colors, design, repeatability and uniformity of the material allow to realize the needs of an investor or an architect perfectly. Prefabrication, transport and repeatable installation enable to minimize the costs of obtaining a completed object. In branches as agriculture, processing, warehousing and manufacturing, the ARPANEL sandwich panels meet necessary standards of endurance, resistance to fire, hygienic and acoustic conditions. The ARPANEL products meet all requirements of national Office of Technical Inspection, supervisory bodies and European standards. Therefore, our product has its place within the group of leaders of European manufacturers of sandwich panels. Exemplary branches and types of investor applying the sandwich panels: warehouses and logistic centers, production halls, fruit-vegetables processing plants and warehouses, meat and fish processing plants, meat and fish refrigerators and freezers, food industry, car factories and showrooms, shopping centers and retail, factories and heavy industry - envelope constructions, renovations an preparation of new light envelope constructions - industry and commerce, garages and pavilions, gyms and sport halls, hangars, civil and military accompanying objects, welfare, office and warehouse units for construction, gas and oil sites, sea and military containers, objects of animals breeding, canopies for car containers, warehouses for cereals, cereal and plant products. Exemplary applications of the ARPANEL S MiWo wall sandwich panels: warehouse and production halls with an elevated fire resistance class, fire partitioning walls, external and internal, noise covers and barriers for objects with elevated noise parameters, civil, military and aircraft hangars and garages, residential and office containers, measurement and research tunnels, factories, warehouses and timber drying facilities, chemical objects housings, sound proof partitions, so-called acoustic. Universal application allows the designers and architects to realize basic and varied objects, meeting all requirements of contemporary construction practice. 20 ARPANEL sandwich panels system

21 2.9 Thermal insulation Polyurethane that creates the core of the ARPANEL sandwich panels, is characterized with very good thermal insulation. The computational coefficient of thermal conduction is W/m*K. The thermal transmission coefficient U is provided in the table below, presenting technical parameters of the panels. The thermal parameters obtained in case of the ARPANEL S MiWo panels meet the necessary requirements of standards with a minimum thickness of the internal core. Value of thermal transmission coefficient of the ARPANEL sandwich panels Scope of application of those sandwich panels was determined as a result of thermal-humidity calculations, with consideration of influence exerted by thermal bridges, and on the basis of requirements included in the Resolution of the Minister of Infrastructure on technical conditions that should be met by buildings and their location. (Official Journal Dz.U. No 75/2002 item 690). The ARPANEL wall sandwich panels are characterized with thermal insulation allowing to apply them in envelope construction of external walls with full structure and with holes, in public utility and industrial buildings with heated rooms, to the temperature t > 16 C. The ARPANEL roof sandwich panels are characterized with thermal insulation allowing to apply them as roof coating over rooms in public utility and industrial buildings, with heated rooms, to the temperature t >16 C. Panel type ARPANEL S PUR/PIR wall sandwich panel* - a standard fastening ARPANEL SU PUR/PIR wall sandwich panel* - a hidden fastening system ARPANEL D PUR/PIR roof sandwich panel* Core thickness Thermal trensmittence mm U 0 = W/(m 2 x K) 40 0, , , , , , , ,19 40/80 0,53 60/100 0,36 80/120 0,27 100/140 0,22 The ARPANEL MiWo panels are characterized with a good level of thermal insulations thanks to a very good thermal conductivity coefficient. It has been achieved thanks to application of proper mineral wool and so-called louver assembly method for the internal core. The louver assembly allows to remove local thermal bridges from the panel, and their application perpendicularly to the linings increased the technical parameters significantly. Additionally, the interlocking contact spot is milled in such a manner that the created gasket-free contact point protects the wall thermally. Hydrophobized fibers are protected from humidity, biological corrosion, and local condensation of water vapor. Sealing mass needs to be applied in the steel profiles of the interlocking system during assembly, which eliminates penetration by air and humidity. The technical parameters of wall panels as a thermal permeation parameter are presented in a table of the Uo coefficient. 120/160 0, ,17 ARPANEL CH PUR/PIR Cooling room 160 0,13 sandwich panel*, **** 200 0, , ,39 ARPANEL S MiWo wall 120 0,32 sandwich panel** - a standard fastening 150 0,26 system 180 0, , *** 0,18 * PUR/PIR thickness -40 +/- 3 kg cladding 0.5 mm / 0.5 mm ** MiWo thickness 105 kg/m 3, cladding 0.6 mm / 0.5 mm *** Thickness of 220 mm is produced on special order after consultation with the manufacturer **** The thermal transmittance coefficient (U d,s ) value was calculated for a temperature of 0 C. The design thermal conductivity value (λ design ) at 0 C is 0,021 W/m*K 21 ARPANEL sandwich panels system

22 2.10 Reaction to the fire and fire resistance parameters The PUR/PIR and MiWo wall and roof sandwich panels were tested in the ITB laboratory as materials to be applied in the construction industry. The wall and roof sandwich panels were tested in the Building Research Institute (ITB) in Warsaw, as materials for application in construction industry. Among others, basic parameters such as resistance to fire and spread of fire were tested and determined. After completion of the type tests, according to the PN-EN 14509, the ITB prepared a Report from Examinations. The table presents a comparison of tested parameters together with the standards which governed classification of the parameters. Fire classification of ARPANEL sandwich panels Panel type Thickness of the core Resistance to fire acc. to name mm PN-B NRO Reaction on fire acc. to Resistance to fire acc. to PN-EN PN-EN PUR PIR MiWo PIR MiWo Resistance to fire acc. to PN-EN ARPANEL S PUR/PIR wall sandwich panel* - a standard fastening ARPANEL SU PUR/PIR wall sandwich panel* - a hidden fastening system 60 NRO 80 NRO B-s3,d0 B-s2,d0 100 NRO EI 30 / E NRO 80 NRO D-s3,d0 100 NRO EI 20 / E NRO EI 30 / E 30 B-s2,d0 40/80 NRO Broof(t1) ARPANEL D PUR/PIR roof sandwich panel* 60/100 NRO Broof(t1) D-s3,d0 B-s2,d0 80/120 NRO Broof(t1) 100/140 NRO Broof(t1) REI 30 / RE /160 NRO Broof(t1) ARPANEL CH PUR/PIR Cooling room sandwich panel* 120 NRO 160 NRO 200 NRO B-s3,d0 B-s2,d0 EI 30 / E NRO El 60 / E NRO EI 60 / E 120 ARPANEL S MiWo wall sandwich panel** - a standard fastening system 120 NRO EI 120 / E NRO 160 NRO 180 NRO 200 NRO A 2 -s1,d0 El 240 / E *** NRO * PUR/PIR thickness -40 +/- 3 kg cladding 0.5 mm / 0.5 mm ** MiWo thickness 105 kg/m 3, cladding 0.6 mm / 0.5 mm *** Thickness of 220 mm is produced on special order after consultation with the manufacturer 22 ARPANEL sandwich panels system

23 2.11 Acoustic parameters of the ARPANEL sandwich panels Acoustic qualities of the ARPANEL sandwich panels were tested in accordance to the PN-EN :1999 standard. The coefficients provided in the tables pose the upper impassable threshold of permitted proper acoustic insulation Rw. The ARPANEL panels, in acoustic respect, may be used for both external envelope construction of the objects as well as internal walls. As acoustic partitions, they can be applied for construction of commercial and exhibition pavilions, as well as technological chambers and tunnels. In arrangements of acoustic protection there is also a need to consider amounts and types of glazings, doorways, location of devices and other fillings of walls and roofs. Acoustic qualities of the ARPANEL sandwich panels Panel type Core thickness Proper acoustic insulation Noise absorption index name mm Rw(C,Ctr) db αw (-3.-4) 0,15 ARPANEL S PUR/PIR wall sandwich panel* - a standard fastening (-3.-4) 0, (-3.-4) 0, (-2.-4) 0, (-3.-4) 0,15 ARPANEL SU PUR/PIR wall sandwich panel* - a hidden fastening system (-3.-4) 0, (-2.-4) 0, (-2;-4) 0,15 40/80 26 (-3.-4) 0,15 ARPANEL D PUR/PIR roof sandwich panel* 60/ (-3.-4) 0,15 80/ (-3.-4) 0,15 100/ (-1,-4) 0,15 120/ (-2,-4) 0,15 ARPANEL CH PUR/PIR Cooling room sandwich panel* (-2.-4) 0, (-2.-4) 0, (-2.-4) 0, (-1,-2) 0, (-1,-3) 0,15 ARPANEL S MiWo wall sandwich panel** - a standard fastening system (-1,-3) 0, (-1,-3) 0, (-1,-3) 0, (-1,-3) 0, *** 31 (-1,-3) 0,15 * PUR/PIR thickness -40 +/- 3 kg cladding 0.5 mm / 0.5 mm ** MiWo thickness 105 kg/m3, cladding 0.6 mm / 0.5 mm *** Thickness of 220 mm is produced on special order after consultation with the manufacturer 23 ARPANEL sandwich panels system

24 24 ARPANEL sandwich panels system

25 3. Technical details - exemplary solutions 25 Technical details - exemplary solutions

26 3.1 Horizontal facade system Horizontal facade system Position Figure 1.1 Drip detail - version Drip detail - version Drip detail version Fastening of panels to the steel structure 1.5 Fastening of panels to the steel column detail - omega profile 1.6 Fastening of panels to the reinforced concrete column detail 1.7 Fastening of panels to the steel column detail - external corner 1.8 Fastening of panels to the steel column detail - internal corner 1.9 Panel connection to concrete wall 1.10 Window detail 1.11 Gate detail 1.12 Doors detail 26 ARPANEL sandwich panels system

27 3.1 Horizontal facade system Horizontal facade system 1.1 Starting detail - version 1 Position Item 1 Construction element 2 ARPANEL S wall panel 3 Drip cap flashing 4 A fixing profile according to the structural design 5 Ground substitute 6 Tight rivet 7 Screw according to the structural design 8 Butyl sealing tape 9 Sealing tape 27 Technical details - exemplary solutions

28 3.1 Horizontal facade system 1.2 Drip detail - version 2 Position Item 1 Construction element 2 ARPANEL SU wall panel 3 Drip cap flashing 4 A fixing profile according to the structural design 5 Thermal insulation 6 Ground substitute 7 Tight rivet 8 Screw according to the structural design 9 Butyl sealing tape 28 Technical details - exemplary solutions

29 3.1 Horizontal facade system Horizontal facade system 1.3 Drip detail version 3 Position Item 1 Steel column according to the structural design 2 ARPANEL S wall panel 3 Drip cap flashing 4 A fixing profile according to the structural design 5 Thermal insulation 6 Ground substitute 7 Tight rivet 8 Sealing tape 29 Technical details - exemplary solutions

30 3.1 Horizontal facade system 1.4 Fastening of panels to the steel structure Position Item 1 Steel column according to the structural design 2 ARPANEL S wall panel 3 Joint flashing 4 Sealing tape 5 Fixing screw 6 Screw 7 Thermal insulation 30 Technical details - exemplary solutions

31 3.1 Horizontal facade system Horizontal facade system 1.5 Fastening of panels to the steel column detail - omega profile Position Item 1 Steel column according to the structural design 2 ARPANEL SU wall panel 3 Joint flashing 4 Sealing tape 5 Fixing screw 6 Tight rivet 7 Thermal insulation 8 Fastening washer/ fastening plate element 31 Technical details - exemplary solutions

32 3.1 Horizontal facade system 1.6 Fastening of panels to the reinforced concrete column detail Position Item 1 Reinforced concrete column according to the structural design 2 ARPANEL S wall panel 3 Joint flashing 4 Sealing tape 5 Fixing screw 6 Screw 7 Thermal insulation 32 Technical details - exemplary solutions

33 3.1 Horizontal facade system Horizontal facade system thermal dilatation in the coating, 20 mm 1.7 Fastening of panels to the steel column detail - external corner Position Item 1 Steel column according to the structural design 2 ARPANEL S wall panel 3 Corner flashing 4 L profile according to the structural design 5 Fixing screw 6 Tight rivet 7 Sealing tape 8 Thermal insulation 33 Technical details - exemplary solutions

34 3.1 Horizontal facade system 1.8 Fastening of panels to the steel column detail - internal corner Position Item 1 Steel column according to the structural design 2 ARPANEL S wall panel 3 Corner flashing 4 L profile according to the structural design 5 Tight rivet 6 Fixing screw 7 Fixing screw 8 Thermal insulation 9 Sealing tape 34 Technical details - exemplary solutions

35 3.1 Horizontal facade system Horizontal facade system 1.9 Panel connection to concrete wall Position Item 1 Construction element 2 ARPANEL S wall panel 3 Masking flashing 4 Individual flashing 5 Fixing screw 6 Tight rivet 7 Screw 8 Thermal insulation 9 Sealing tape 35 Technical details - exemplary solutions

36 3.1 Horizontal facade system Vertical cross-section Horizontal cross-section 1.10 Window detail Position Item 1 Steel beam according to the structural design 2 ARPANEL S wall panel 3 L profile according to the structural design 4 Top drip cap of the hole 5 Masking frame of the drip cap / individual flashing 6 Bottom drip cap of the hole 7 Side masking frame of the hole Position Item 8 Individual flashing 9 Individual flashing 10 Tight rivet 11 Fixing screw 12 Thermal insulation 13 Sealing tape 14 Mounting foam 36 Technical details - exemplary solutions

37 3.1 Horizontal facade system Vertical facade system 1.11 Gate detail Position Item 1 Steel beam according to the structural design 2 ARPANEL S wall panel 3 L profile according to the structural design 4 Z profile according to the structural design 5 Top drip cap of the hole 6 Drip cap flashing 7 Individual flashing 8 Individual flashing 9 Fixing screw 10 Tight rivet 11 Thermal insulation 12 Sealing tape 37 Technical details - exemplary solutions

38 3.1 Horizontal facade system 1.12 Doors detail Position Item 1 Steel beam according to the structural design 2 ARPANEL S wall panel 3 C profile according to the structural design 4 Top drip cap of the hole 5 Individual flashing 6 Individual flashing 7 Individual flashing 8 Fixing screw 9 Tight rivet 10 Thermal insulation 11 Sealing tape 12 Sealing tape 13 Mounting foam 38 Technical details - exemplary solutions

39 3.2 Vertical facade system Vertical facade system Vertical facade system Position Figure 2.1 Panel Connection to construction element 2.2 Starting detail version Starting detail version Attic detail 2.5 Wall and roof panel connection 2.6 Fastening of panels on the flor 2.7 Prolongation of vertical panels 2.8 External corner detail 2.9 Panel connection to the brick wall 2.10 Window detail 2.11 Gate detail 39 Technical details - exemplary solutions

40 3.2 Vertical facade system 2.1 Panel connection to construction element Position Item 1 Steel beam according to the structural design 2 ARPANEL SU wall panel 3 Fastening washer/ fastening plate element 4 Fixing screw 5 Sealing tape 40 Technical details - exemplary solutions

41 3.2 Vertical facade system Vertical facade system 2.2 Starting detail version 1 Position Item 1 ARPANEL SU wall panel 2 L profile according to the structural design 3 L profile according to the structural design 4 Masking flashing 5 Drip cap flashing 6 Fixing screw 7 Tight rivet 8 Screw 9 Screw according to the structural design 10 Butyl sealing tape 11 Butyl sealing tape 12 Fastening washer/ fastening plate element 41 Technical details - exemplary solutions

42 3.2 Vertical facade system 2.3 Starting detail version 2 Position Item 1 ARPANEL SU wall panel 2 L profile according to the structural design 3 Masking flashing 4 Drip cap flashing 5 Fixing screw 6 Tight rivet 7 Screw 8 Screw according to the structural design 9 Butyl sealing tape 10 Sealing tape 11 Fastening washer/ fastening plate element 12 Thermal insulation 42 Technical details - exemplary solutions

43 3.2 Vertical facade system Vertical facade system 2.4 Attic detail Position Item 1 Construction element 2 Construction element 3 ARPANEL SU wall panel 4 ARPANEL roof panel 5 Attic flashing 6 Individual flashing 7 Tight rivet 8 Fixing screw 9 Fixing screw 10 Thermal insulation 11 Sealing tape 12 Fastening washer/ fastening plate element 43 Technical details - exemplary solutions

44 3.2 Vertical facade system 2.5 Wall and roof panel connection Position Item 1 Construction element 2 ARPANEL SU wall panel 3 ARPANEL roof panel 4 Individual flashing 5 Construction element 6 Fixing screw 7 Fixing screw 8 Tight rivet 9 Thermal insulation 10 Fastening washer/ fastening plate element 11 Sealing tape 44 Technical details - exemplary solutions

45 3.2 Vertical facade system Vertical facade system 2.6 Fastening of panels on the flor Position Item 1 ARPANEL wall panel 2 Masking flashing 3 Construction element 4 Tight rivet 5 Fixing screw 6 Screw 7 Screw according to the structural design 8 Impregnated polyurethane seal 45 Technical details - exemplary solutions

46 3.2 Vertical facade system 2.7 Prolongation of vertical panels Position Item 1 Construction element 2 ARPANEL SU wall panel 3 Individual flashing 4 Masking flashing 5 Fixing screw 6 Thermal insulation 7 Sealing tape 8 Fastening washer/ fastening plate element 46 Technical details - exemplary solutions

47 3.2 Vertical facade system Vertical facade system Thermal dilatation in the coating, 20 mm 2.8 External corner detail Position Item 1 Steel column according to the structural design 2 Construction element 3 ARPANEL SU wall panel 4 L profile according to the structural design 5 Corner flashing 6 Fixing screw 7 Fixing screw 8 Tight rivet 9 Sealing tape 10 Thermal insulation 11 Fastening washer/ fastening plate element 47 Technical details - exemplary solutions

48 3.2 Vertical facade system 2.9 Panel connection to bricked walls Position Item 1 Construction element 2 ARPANEL SU wall panel 3 Individual flashing 4 Individual flashing 5 Fixing screw 6 Tight rivet 7 Screw 8 Thermal insulation 9 Sealing tape 10 Fastening washer/ fastening plate element 48 Technical details - exemplary solutions

49 3.2 Vertical facade system Vertical cross-section Horizontal cross-section Vertical facade system 2.10 Window detail Position Item Position Item 1 Steel beam according to the structural design 2 ARPANEL SU wall panel 3 L profile according to the structural design 4 Top drip cap of the hole 5 Drip cap masking frame 6 Bottom drip cap of the hole 7 Side masking frame of the hole 9 Sealing tape 10 Tight rivet 11 Fixing screw 12 Thermal insulation 13 Butyl sealing tape 14 Fastening washer/ fastening plate element 15 Mounting foam 8 Individual flashing 49 Technical details - exemplary solutions

50 3.2 Vertical facade system 2.11 Gate detail Position Item 1 Steel beam according to the structural design 2 ARPANEL SU wall panel 3 L profile according to the structural design 4 Z profile according to the structural design 5 Top drip cap of the hole 6 Drip cap flashing 7 Individual flashing 8 Fixing screw 9 Tight rivet 10 Thermal insulation 11 Sealing tape 12 Fastening washer/ fastening plate element 50 Technical details - exemplary solutions

51 3.2 Panel roofing system Panel roofing system Position Figure 3.1 Roof panel conection 3.2 Roof panel connection to the brick wall 3.3 Ridge detail 3.4 Gutter element detail version Gutter element detail version Snow guard element 3.7 Internal gutter detail 3.8 Skylight detail 3.9 Flange sealing detail 3.10 Dilatation detail 51 Technical details - exemplary solutions

52 3.2 Panel roofing system Cross-section 3.1 Roof panel conection Position Item 1 Construction element 2 ARPANEL D roof panel 3 Fixing screw 4 Self-drilling screw 5 Sealing tape 6 Sealing tape 7 Butyl sealing tape 8 Washer (calotte) 52 Technical details - exemplary solutions

53 3.2 Panel roofing system Bend upwards 3.2 Roof panel connection to the brick wall Position Item 1 Construction element 2 ARPANEL D roof panel 3 Roof slope flashing 4 Closing flashing - profiled 5 Individual flashing 6 Individual flashing 7 Fixing screw 8 Screw 9 Self-drilling screw 10 Tight rivet 11 Sealing tape 12 Profiled seal 13 Butyl sealing mass 14 Thermal insulation 53 Technical details - exemplary solutions

54 3.2 Panel roofing system Bend upwards 3.3 Ridge detail Position Item 1 Construction element 2 ARPANEL D roof panel 3 Top ridge flashing 4 Bottom ridge flashing 5 Closure flashing 6 Individual flashing 7 Tight rivet 8 Self-drilling screw 9 Fixing screw 10 Polyethylene sealing tape 11 Thermal insulation 12 Profiled seal 54 Technical details - exemplary solutions

55 3.2 Panel roofing system 3.4 Gutter element detail version 1 Position Item 1 ARPANEL D roof panel 2 ARPANEL S wall panel 3 Gutter drip cap 4 Individual flashing 5 Masking flashing 6 Individual flashing 7 Self-drilling screw 8 Screw 9 Tight rivet 10 Thermal insulation 11 Guttering according to the discipline design 55 Technical details - exemplary solutions

56 3.2 Panel roofing system 3.5 Gutter element detail version 2 Position Item 1 Roofing according to the architectural design 2 ARPANEL S wall panel 3 Gutter drip cap 4 Individual flashing 5 Individual flashing 6 Individual flashing 7 Screw 8 Self-drilling screw 9 Tight rivet 10 Thermal insulation 11 Guttering according to the discipline design 12 Sealing tape 56 Technical details - exemplary solutions

57 3.2 Panel roofing system 3.6 Snow guard element Position Item 1 Construction element 2 ARPANEL D roof panel 3 Fixing screw 4 Self-drilling screw 5 Sealing tape 6 Snow guard 57 Technical details - exemplary solutions

58 3.2 Panel roofing system 3.7 Internal gutter detail Position Item 1 Construction element 2 Construction element 3 ARPANEL D roof panel 4 ARPANEL SU wall panel 5 Individual flashing 6 Individual flashing 7 Gutter drip cap Position Item 8 Fixing screw 9 Screw 10 Fixing screw 11 Tight rivet (every 300 mm) 12 Internal gutter according to architectural design 13 Butyl sealing tape 14 Membrane 58 Technical details - exemplary solutions

59 3.2 Panel roofing system Bend upwards 3.8 Skylight detail Position Item 1 Construction element 2 ARPANEL D roof panel 3 Skylight steel frame 4 Individual profiled flashing 5 Individual flashing 6 Self-drilling screw 7 Fixing screw 8 Tight rivet 9 Butyl sealing tape 10 Thermal insulation 11 Profiled seal 59 Technical details - exemplary solutions

60 3.2 Panel roofing system 3.9 Flange sealing detail Position Item 1 Construction element 2 ARPANEL D roof panel 3 Fixing screw 4 Screw 5 Sealing flange for roof penetration 6 Sealing lute 60 Technical details - exemplary solutions

61 3.2 Panel roofing system 3.10 Dilatation detail Position Item 1 Construction element 2 ARPANEL roof panel 3 Individual flashing 4 Individual flashing 5 Individual flashing 6 Fixing screw 7 Fixing screw 8 Self-drilling screw 9 Tight rivet 10 Thermal insulation 11 Sealing tape 61 Technical details - exemplary solutions

62 3.4 Panel walls system for cooling rooms Panel walls system for cooling rooms Roof bearing structure Suspended ceiling Structures external sprandel beams Tropic roof/panel Position Figure 4.1 Longitudinal joint of ARPANEL panels 4.2 Cooling room panels fastening details with PCV connectors 4.3 Panels fastening system detail with insulation nuts 4.4 Panels fastening detail to the sprandel beam 4.5 Suspended in the ceiling detail with insulation nuts 4.6 Longitudinal jointing of the wall panels detail 4.7 Jointing of wall and roof panels in the corner detail 4.8 Fastening of wall panels in the corner detail 4.9 Suspension of panels on the ceiling detail with T-profiles 4.10 Suspension of panels on the ceiling detail with Omega profiles 4.11 Jointing the partition wall with the internal wall detail 4.12 Jointing of the external wall with concrete plinth detail 4.13 Jointing of the external wall with PCV plinth detail 4.14 Jointing of the external wall with concrete floor and plinth detail 4.15 Jointing of the partition wall with the ceiling detail 4.16 Jointing of the external wall with the door frame detail 62 Technical details - exemplary solutions

63 3.4 Panel walls system for cooling rooms internal side of the object ARPANEL sandwich panels system 4.1 Longitudinal joint of ARPANEL panels Position Item 1 ARPANEL CH cooling room panel 2 A milled joint in a shape of a female and male flange, removing the linear thermal bridge 3 Sealing mass preventing infiltration of water vapor and air 4 Gap allowing to apply sealing mass that is plastically durable 5 Double-sided shape of the panels joint spot, in a form of a double interlocking system 6 Inclination of the panel s joint surface, facilitating the assembly process 63 Technical details - exemplary solutions

64 3.4 Panel walls system for cooling rooms 4.2 Cooling room panels fastening detail with PCV connectors Position Item 1 ARPANEL CH cooling room panel 2 Panel fastening joint 3 PCV sleeve 4 PCV plug 5 Wall sprandel beam according to the structural design 6 Polyurethane self-adhesive tape 64 Technical details - exemplary solutions

65 3.4 Panel walls system for cooling rooms ARPANEL sandwich panels system 4.3 Panels fastening system detail with insulation nuts Position Item 1 ARPANEL CH cooling room panel 2 Threaded rod 3 PCV insulation nut 4 PCV washer 5 Permanently plastic mass 6 Object s structural element 7 Washer 8 Butyl sealing tape 9 Polyurethane self-adhesive tape 65 Technical details - exemplary solutions

66 3.4 Panel walls system for cooling rooms internal side of the object 4.4 Panels fastening detail to the sprandel beam Position Item 1 ARPANEL CH cooling room panel 2 Sealing mass preventing infiltration of water vapor and air 3 Gap allowing to apply sealing mass that is plastically durable 4 Bearing washer 5 Protective cap 6 Screw 7 Washer 8 Polyamide sleeve 9 Polyurethane self-adhesive tape 10 Wall sprandel beam according to the structural design 66 Technical details - exemplary solutions

67 3.4 Panel walls system for cooling rooms Vertical cross-section Horizontal cross-section ARPANEL sandwich panels system 4.5 Suspended in the ceiling detail with insulation nuts Position Item 1 ARPANEL CH cooling room panel 2 Threaded rod 3 PCV insulation nut 4 PCV washer 5 Permanently plastic mass 6 Washer 7 Nut 8 Polyurethane self-adhesive tape 9 Steel joist according to the structure 67 Technical details - exemplary solutions

68 3.4 Panel walls system for cooling rooms 4.6 Longitudinal jointing of the wall panels detail Position Item 1 ARPANEL CH cooling room panel 2 Masking flashing 3 Tight rivet 4 Mounting polyethylene foam 5 Permanently plastic mass 6 Polyurethane self-adhesive tape 7 Wall sprandel beam according to the structural design 68 Technical details - exemplary solutions

69 3.4 Panel walls system for cooling rooms WARIANT I WARIANT II ARPANEL sandwich panels system 4.7 Jointing of wall and roof panels in the corner detail Position Item 1 ARPANEL CH cooling room panel 2 Mounting polyethylene foam 3 Permanently plastic mass 4 Polyethylene foam 5 External corner flashing 6 Tight rivet 7 PCV fastening profile 8 PCV corner profile 9 Internal corner flashing 69 Technical details - exemplary solutions

70 3.4 Panel walls system for cooling rooms VARIANT II VARIANT I 4.8 Fastening of wall panels in the corner detail Position Item 1 ARPANEL CH cooling room panel 2 Mounting polyethylene foam 3 Permanently plastic mass 4 Polyethylene foam 5 External corner flashing 6 Tight one-sided rivet 7 PCV fastening profile 8 PCV corner profile Position Item 9 Internal corner flashing 10 Threaded rod 11 Washer 12 Nut 13 PCV washer 14 PCV insulation nut 15 Steel beam according to the structural design 16 Column according to the structural design 70 Technical details - exemplary solutions

71 3.4 Panel walls system for cooling rooms ARPANEL sandwich panels system 4.9 Suspension of panels on the ceiling detail with T-profiles Position Item 1 ARPANEL CH cooling room panel 2 Bracket - coupling 3 T profile (TALU 01 aluminum or PUL 01 / PUL 02 polyester) 4 Polyethylene self-adhesive tape 5 Screw 6 Washer 7 Nut 8 Mounting polyurethane foam 9 Permanently plastic mass 71 Technical details - exemplary solutions

72 3.4 Panel walls system for cooling rooms 4.10 Suspension of panels on the ceiling detail with Omega profiles Position Item 1 ARPANEL CH cooling room panel 2 Bracket - coupling 3 T profile (TALU 01 aluminum or PUL 01 / PUL 02 polyester) 4 Polyethylene self-adhesive tape 5 Screw 6 Washer 7 Nut 8 Mounting polyurethane foam 9 Permanently plastic mass 72 Technical details - exemplary solutions

73 3.4 Panel walls system for cooling rooms VARIANT I Cladding removed at the width of a=d - 30 mm VARIANT II VARIANT III ARPANEL sandwich panels system 4.11 Jointing the partition wall with the internal wall detail Position Item 1 ARPANEL CH cooling room panel 2 ARPANEL CH cooling room panel 3 PCV fastening profile 4 Tight rivet 5 PCV corner profile 6 Mounting polyethylene foam 7 Permanently plastic mass 8 Internal corner flashing 9 Internal corner flashing 73 Technical details - exemplary solutions

74 3.4 Panel walls system for cooling rooms the cladding removed at the level of thermal Jointing of the external wall with concrete plinth detail Position Item 1 Concrete panel according to the structural design 2 ARPANEL CH cooling room panel 3 Thermal insulation 4 Humidity insulation, vertical and horizontal 5 Concrete floor according to the structural design 6 Permanently plastic mass 7 PCV corner profile 74 Technical details - exemplary solutions

75 3.4 Panel walls system for cooling rooms the cladding removed at the level of thermal ARPANEL sandwich panels system 4.13 Jointing of the external wall with PCV plinth detail Position Item 1 Concrete panel according to the structural design 2 ARPANEL CH cooling room panel 3 Thermal insulation 4 Humidity insulation, vertical and horizontal 5 Concrete floor according to the structural design 6 PCV plinth 7 Wall support of the buffer 8 Fixing screw 9 Buffer s cover 75 Technical details - exemplary solutions

76 3.4 Panel walls system for cooling rooms min. 150 mm g min. 150 mm the cladding removed at the level of thermal 4.14 Jointing of the external wall with concrete floor and plinth detail Position Item 1 Concrete panel according to the structural design 2 Humidity insulation, vertical and horizontal 3 Thermal insulation 4 ARPANEL CH cooling room panel 5 Cold-rolled profile 6 Anchor to the concrete 7 Self-drilling joint Position Item 8 Concrete plinth according to the structural design 9 External corner flashing 10 Butyl mass 11 Tight one-sided rivet 12 Permanently plastic mass 13 PCV corner profile 14 Concrete floor according to the structural design 76 Technical details - exemplary solutions

77 3.4 Panel walls system for cooling rooms VARIANT I the cladding removed at the level of thermal CEILING ARPANEL sandwich panels system WALL VARIANT II VARIANT III 4.15 Jointing of the partition wall with the ceiling detail Position Item 1 ARPANEL CH cooling room panel 2 ARPANEL CH cooling room panel 3 PCV fastening profile 4 Tight rivet 5 PCV corner profile 6 Mounting polyethylene foam 7 Permanently plastic mass 8 Internal corner flashing 9 Internal corner flashing 77 Technical details - exemplary solutions

78 3.4 Panel walls system for cooling rooms 4.16 Jointing of the external wall with the door frame detail Position Item 1 ARPANEL CH cooling room panel 2 Cooling room doors 3 Mounting polyurethane foam 4 Self-drilling joint 5 Permanently plastic mass 78 Technical details - exemplary solutions

79 4. Resistance tables 79 Resistance tables

80 4. Resistance tables ARPANEL sandwich panels were tested in terms of permitted load by the Institute of Construction Technology (ITB) in Warsaw. Taking into consideration results of the laboratory tests and the assumptions presented below, load tables for the ARPANEL panels have been developed. Obliczenia wykonane przy założeniach: Thickness of external steel cladding with PUR/PIR core Thickness of external steel cladding with MiWo core Thickness of internal steel cladding Modulus of elasticity of claddings PUR/PIR core density MiWo core density 0,5 mm 0,6 mm 0,5 mm 210 GPa 40,0 kg/m 3 105,0 kg/m 3 Claddings density 7850 kg/m 3 Width of extreme support Width of central support (for two- and three-span arrangements) 40 mm 60 mm Creep coefficient (for roof panels) Ф Internal ambient temperature during winter 20 C Internal ambient temperature during summer 25 C External temperature during winter External temperature during winter (tables for ARPANEL CH refrigerating sandwich panels) -20 C -40 C External temperature during summer 1st gr. (very light colors) 55 C External temperature during summer 2 nd gr. (light colors) 65 C External temperature during summer 3 rd gr. (dark colors) 80 C Permitted bending of wall panels L/100 Permissible deflection of roof panels with PUR/PIR core (temporary loads) L/200 Permissible deflection of roof panels with PUR/PIR core (permanent loads) L/100 The load values provided in the tables are maximal wind (thrust and suction) and snow (thrust) load values, for which all conditions of bearing capacity in every adequate loads combinations are met. The values provided for SGU are characteristic, and for SGN computational. 80 Resistance tables

81 4. Resistance tables 1. Maximal values of wind load (thrust and suction) for ARPANEL S PUR/PIR 40 wall sandwich panels, single-span arrangment 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 3,68 3,24 3,98 5,83 3,68 3,24 3,98 5,83 3,68 3,24 3,98 5,83 1,8 2,56 2,25 3,03 4,05 2,56 2,25 3,03 4,05 2,56 2,25 3,03 4,05 2,1 1,88 1,65 2,36 2,98 1,88 1,65 2,36 2,98 1,88 1,65 2,24 2,98 2,4 1,44 1,27 1,86 2,28 1,44 1,27 1,86 2,28 1,44 1,27 1,67 2,28 2,7 1,14 1 1,49 1,8 1,14 1 1,44 1,8 1,14 1 1,26 1,8 3 0,92 0,81 1,21 1,46 0,92 0,81 1,12 1,46 0,92 0,81 0,85 1,46 3,3 0,76 0,67 0,98 1,2 0,76 0,67 0,88 1,2 0,76 0,67 0,55 1,2 3,6 0,58 0,56 0,78 1,01 0,58 0,56 0,69 1,01 0,58 0,56 0,33 1,01 3,9 0,4 0,48 0,63 0,86 0,4 0,48 0,51 0,86 0,4 0,48 0,17 0,86 4,2 0,26 0,41 0,51 0,74 0,26 0,41 0,36 0,74 0,26 0,41 0,06 0,74 4,5 0,16 0,36 0,42 0,65 0,16 0,36 0,25 0,65 0,16 0,36-0,65 4,8 0,08 0,32 0,34 0,57 0,08 0,32 0,17 0,57 0,08 0,32-0,57 5,1 0,03 0,28 0,26 0,5 0,03 0,28 0,1 0,5 0,03 0,28-0,5 5,4-0,25 0,2 0,45-0,25 0,05 0,45-0,25-0,45 5,7-0,22 0,15 0,4-0,22 0,02 0,4-0,22-0,4 6-0,2 0,11 0,36-0,2-0,36-0,2-0,36 6,3-0,18 0,08 0,33-0,18-0,33-0,18-0,33 6,6-0,17 0,05 0,3-0,17-0,3-0,17-0,3 6,9-0,15 0,03 0,28-0,15-0,28-0,15-0,28 7,2-0,14 0,01 0,25-0,14-0,25-0,14-0,25 7,5-0,13-0,23-0,13-0,23-0,13-0,23 7,8-0,12-0,22-0,12-0,22-0,11-0,22 8,1-0,11-0,2-0,11-0,2-0,2-0,2 2. Maximal values of wind load (thrust and suction) for ARPANEL S/SU PUR/PIR 60 wall sandwich panels, single-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 4,8 3,47 9,05 8,79 4,8 3,47 9,05 8,79 4,8 3,47 9,05 8,79 1,8 3,84 2,89 6,89 6,1 3,84 2,89 6,89 6,1 3,84 2,89 6,89 6,1 2,1 2,82 2,48 5,1 4,48 2,82 2,48 5,1 4,48 2,82 2,48 5,1 4,48 2,4 2,16 1,9 3,9 3,43 2,16 1,9 3,9 3,43 2,16 1,9 3,9 3,43 2,7 1,71 1,5 3,08 2,71 1,71 1,5 3,08 2,71 1,71 1,5 3,08 2,71 3 1,38 1,22 2,5 2,2 1,38 1,22 2,5 2,2 1,38 1,22 2,5 2,2 3,3 1,14 1 2,06 1,82 1,14 1 2,06 1,82 1,14 1 2,06 1,82 3,6 0,96 0,84 1,73 1,53 0,96 0,84 1,73 1,53 0,96 0,84 1,68 1,53 3,9 0,82 0,72 1,48 1,3 0,82 0,72 1,48 1,3 0,82 0,72 1,34 1,3 4,2 0,71 0,62 1,27 1,12 0,71 0,62 1,25 1,12 0,71 0,62 1,06 1,12 4,5 0,61 0,54 1,11 0,98 0,61 0,54 1,03 0,98 0,61 0,54 0,79 0,98 4,8 0,54 0,48 0,94 0,86 0,54 0,48 0,85 0,86 0,54 0,48 0,58 0,86 5,1 0,48 0,42 0,79 0,76 0,48 0,42 0,71 0,76 0,48 0,42 0,41 0,76 5,4 0,43 0,38 0,67 0,68 0,43 0,38 0,6 0,68 0,43 0,38 0,29 0,68 5,7 0,38 0,34 0,57 0,61 0,38 0,34 0,48 0,61 0,38 0,34 0,19 0,61 6 0,29 0,3 0,49 0,55 0,29 0,3 0,38 0,55 0,29 0,3 0,11 0,55 6,3 0,22 0,28 0,42 0,5 0,22 0,28 0,3 0,5 0,22 0,28 0,05 0,5 6,6 0,16 0,25 0,36 0,45 0,16 0,25 0,23 0,45 0,16 0,25-0,45 6,9 0,11 0,23 0,31 0,42 0,11 0,23 0,18 0,42 0,11 0,23-0,42 7,2 0,07 0,21 0,27 0,38 0,07 0,21 0,13 0,38 0,07 0,21-0,38 7,5 0,04 0,19 0,22 0,35 0,04 0,19 0,1 0,35 0,04 0,19-0,35 7,8 0,01 0,18 0,18 0,33 0,01 0,18 0,07 0,33 0,01 0,17-0,33 8,1-0,17 0,15 0,3-0,17 0,04 0,3-0,3-0,3 81 Resistance tables MiWo CH D S/SU Resistance tables

82 4. Resistance tables 3. Maximal values of wind load (thrust and suction) for ARPANEL S/SU PUR/PIR 80 wall sandwich panels, single-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 13,27 10,49 8,92 7,85 13,27 10,49 8,92 7,85 13,27 10,49 8,92 7,85 1,8 10,26 8,74 6,2 5,45 10,26 8,74 6,2 5,45 10,26 8,74 6,2 5,45 2,1 7,77 6,84 4,55 4,01 7,77 6,84 4,55 4,01 7,77 6,84 4,55 4,01 2,4 5,95 5,23 3,48 3,07 5,95 5,23 3,48 3,07 5,95 5,23 3,48 3,07 2,7 4,7 4,13 2,75 2,42 4,7 4,13 2,75 2,42 4,7 4,13 2,75 2,42 3 3,81 3,35 2,23 1,96 3,81 3,35 2,23 1,96 3,81 3,35 2,23 1,96 3,3 3,15 2,77 1,84 1,62 3,15 2,77 1,84 1,62 3,15 2,77 1,84 1,62 3,6 2,64 2,33 1,55 1,36 2,64 2,33 1,55 1,36 2,64 2,33 1,55 1,36 3,9 2,25 1,98 1,32 1,16 2,25 1,98 1,32 1,16 2,25 1,98 1,32 1,16 4,2 1,94 1,71 1,14 1 1,94 1,71 1,14 1 1,94 1,71 1,14 1 4,5 1,69 1,49 0,99 0,87 1,69 1,49 0,99 0,87 1,69 1,49 0,99 0,87 4,8 1,49 1,31 0,87 0,77 1,49 1,31 0,87 0,77 1,49 1,31 0,87 0,77 5,1 1,3 1,16 0,77 0,68 1,3 1,16 0,77 0,68 1,3 1,16 0,77 0,68 5,4 1,1 1,03 0,69 0,61 1,1 1,03 0,69 0,61 1,1 1,03 0,69 0,61 5,7 0,94 0,93 0,62 0,54 0,94 0,93 0,62 0,54 0,94 0,93 0,62 0,54 6 0,8 0,84 0,56 0,49 0,8 0,84 0,56 0,49 0,8 0,84 0,56 0,49 6,3 0,69 0,76 0,51 0,45 0,69 0,76 0,51 0,45 0,69 0,76 0,51 0,45 6,6 0,6 0,69 0,46 0,41 0,6 0,69 0,46 0,41 0,6 0,69 0,4 0,41 6,9 0,49 0,63 0,42 0,37 0,49 0,63 0,42 0,37 0,49 0,63 0,31 0,37 7,2 0,4 0,58 0,39 0,34 0,4 0,58 0,39 0,34 0,4 0,58 0,23 0,34 7,5 0,33 0,54 0,36 0,31 0,33 0,54 0,36 0,31 0,33 0,54 0,17 0,31 7,8 0,27 0,5 0,33 0,29 0,27 0,5 0,33 0,29 0,27 0,46 0,12 0,29 8,1 0,22 0,46 0,31 0,27 0,22 0,46 0,29 0,27 0,22 0,27 0,08 0,27 4. Maximal values of wind load (thrust and suction) for ARPANEL S/SU PUR/PIR 100 wall sandwich panels, single-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 14,36 11,28 11,21 9,86 14,36 11,28 11,21 9,86 14,36 11,28 11,21 9,86 1,8 11,97 9,4 7,78 6,85 11,97 9,4 7,78 6,85 11,97 9,4 7,78 6,85 2,1 9,74 8,06 5,71 5,03 9,74 8,06 5,71 5,03 9,74 8,06 5,71 5,03 2,4 7,45 6,56 4,37 3,85 7,45 6,56 4,37 3,85 7,45 6,56 4,37 3,85 2,7 5,89 5,18 3,45 3,04 5,89 5,18 3,45 3,04 5,89 5,18 3,45 3,04 3 4,77 4,2 2,8 2,46 4,77 4,2 2,8 2,46 4,77 4,2 2,8 2,46 3,3 3,94 3,47 2,31 2,04 3,94 3,47 2,31 2,04 3,94 3,47 2,31 2,04 3,6 3,32 2,92 1,94 1,71 3,32 2,92 1,94 1,71 3,32 2,92 1,94 1,71 3,9 2,82 2,48 1,66 1,46 2,82 2,48 1,66 1,46 2,82 2,48 1,66 1,46 4,2 2,44 2,14 1,43 1,26 2,44 2,14 1,43 1,26 2,44 2,14 1,43 1,26 4,5 2,12 1,87 1,24 1,09 2,12 1,87 1,24 1,09 2,12 1,87 1,24 1,09 4,8 1,86 1,64 1,09 0,96 1,86 1,64 1,09 0,96 1,86 1,64 1,09 0,96 5,1 1,65 1,45 0,97 0,85 1,65 1,45 0,97 0,85 1,65 1,45 0,97 0,85 5,4 1,47 1,3 0,86 0,76 1,47 1,3 0,86 0,76 1,47 1,3 0,86 0,76 5,7 1,32 1,16 0,77 0,68 1,32 1,16 0,77 0,68 1,32 1,16 0,77 0,68 6 1,19 1,05 0,7 0,62 1,19 1,05 0,7 0,62 1,19 1,05 0,7 0,62 6,3 1,08 0,95 0,64 0,56 1,08 0,95 0,64 0,56 1,08 0,95 0,64 0,56 6,6 0,99 0,87 0,58 0,51 0,99 0,87 0,58 0,51 0,99 0,87 0,58 0,51 6,9 0,9 0,79 0,53 0,47 0,9 0,79 0,53 0,47 0,9 0,79 0,53 0,47 7,2 0,83 0,73 0,49 0,43 0,83 0,73 0,49 0,43 0,83 0,73 0,49 0,43 7,5 0,76 0,67 0,45 0,39 0,76 0,67 0,45 0,39 0,76 0,67 0,45 0,39 7,8 0,71 0,62 0,41 0,36 0,71 0,62 0,41 0,36 0,71 0,62 0,41 0,36 8,1 0,65 0,58 0,38 0,34 0,65 0,58 0,38 0,34 0,65 0,58 0,38 0,34 82 Resistance tables

83 4. Resistance tables 5. Maximal values of wind load (thrust and suction) for ARPANEL S PUR/PIR 40 wall sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 2,73 2,97 4,24 2,85 2,73 2,97 2,73 2,05 2,73 2,97 2,73 0,85 1,8 2,23 2 3,35 1,34 2,23 2 2,23 0,78 2,23 2 2,22-2,1 1,88 1,38 2,72 0,7 1,88 1,38 1,88 0,29 1,88 1,38 1,87-2,4 1,62 0,91 2,25 0,39 1,62 0,91 1,62 0,08 1,62 0,91 1,61-2,7 1,42 0,61 1,88 0,23 1,42 0,61 1,42-1,42 0,61 1,42-3 1,27 0,43 1,6 0,15 1,27 0,43 1,27-1,27 0,43 1,27-3,3 1,15 0,3 1,36 0,09 1,15 0,3 1,15-1,15 0,3 1,14-3,6 1,04 0,22 1,18 0,06 1,04 0,22 1,05-1,04 0,22 1,04-3,9 0,96 0,16 1,02 0,04 0,96 0,16 0,96-0,96 0,16 0,96-4,2 0,89 0,12 0,89 0,03 0,89 0,12 0,89-0,89 0,12 0,88-4,5 0,78 0,09 0,78 0,02 0,78 0,09 0,78-0,78 0,09 0,78-4,8 0,68 0,07 0,68 0,01 0,68 0,07 0,68-0,68 0,07 0,68-5,1 0,6 0,05 0,6 0,01 0,6 0,05 0,6-0,6 0,05 0,6-5,4 0,54 0,04 0,54-0,54 0,04 0,54-0,54 0,04 0,54-5,7 0,48 0,03 0,48-0,48 0,03 0,48-0,48 0,03 0,47-6 0,43 0,03 0,43-0,43 0,03 0,43-0,43 0,03 0,42-6,3 0,38 0,02 0,38-0,38 0,02 0,38-0,38 0,02 0,37-6,6 0,34 0,02 0,34-0,34 0,02 0,34-0,34 0,02 0,33-6,9 0,31 0,01 0,31-0,31 0,01 0,31-0,31 0,01 0,29-7,2 0,28 0,01 0,28-0,28 0,01 0,28-0,28 0,01 0,26-7,5 0,25 0,01 0,25-0,25 0,01 0,25-0,25 0,01 0,23-7,8 0,22 0,01 0,23-0,22 0,01 0,23-0,22 0,01 0,21-8,1 0,2 0,01 0,21-0,2 0,01 0,21-0,2 0,01 0,19-6. Maximal values of wind load (thrust and suction) for ARPANEL S PUR/PIR 60 wall sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 2,5 4,47 4,22 4,68 2,5 4,47 2,51 3,48 2,5 4,47 0,74 1,68 1,8 2,03 3,02 3,44 2,21 2,03 3,02 2,04 1,37 2,03 3,02 2,02 0,12 2,1 1,71 2,14 2,9 1,16 1,71 2,14 1,71 0,55 1,71 2,14 1,7-2,4 1,47 1,41 2,5 0,66 1,47 1,41 1,48 0,19 1,47 1,41 1,46-2,7 1,29 0,96 2,19 0,39 1,29 0,96 1,29 0,02 1,29 0,96 1,28-3 1,15 0,67 1,96 0,25 1,15 0,67 1,15-1,15 0,67 1,14-3,3 1,04 0,48 1,77 0,16 1,04 0,48 1,04-1,04 0,48 1,03-3,6 0,94 0,35 1,61 0,11 0,94 0,35 0,95-0,94 0,35 0,94-3,9 0,87 0,26 1,48 0,07 0,87 0,26 0,87-0,87 0,26 0,86-4,2 0,8 0,19 1,37 0,05 0,8 0,19 0,8-0,8 0,19 0,79-4,5 0,74 0,14 1,27 0,03 0,74 0,14 0,75-0,74 0,14 0,74-4,8 0,69 0,11 1,19 0,02 0,69 0,11 0,7-0,69 0,11 0,69-5,1 0,65 0,08 1,12 0,02 0,65 0,08 0,66-0,65 0,08 0,65-5,4 0,61 0,07 1,05 0,01 0,61 0,07 0,62-0,61 0,07 0,61-5,7 0,58 0,05 0,99 0,01 0,58 0,05 0,58-0,58 0,05 0,58-6 0,55 0,04 0,94-0,55 0,04 0,55-0,55 0,04 0,55-6,3 0,52 0,03 0,84-0,52 0,03 0,53-0,52 0,03 0,52-6,6 0,5 0,02 0,76-0,5 0,02 0,5-0,5 0,02 0,49-6,9 0,48 0,02 0,68-0,48 0,02 0,48-0,48 0,02 0,47-7,2 0,46 0,02 0,62-0,46 0,02 0,46-0,46 0,02 0,45-7,5 0,44 0,01 0,56-0,44 0,01 0,44-0,44 0,01 0,43-7,8 0,42 0,01 0,51-0,42 0,01 0,42-0,42 0,01 0,42-8,1 0,4 0,01 0,47-0,4 0,01 0,41-0,4 0,01 0,4-83 Resistance tables MiWo CH D S/SU Resistance tables

84 4. Resistance tables 7. Maximal values of wind load (thrust and suction) for ARPANEL S PUR/PIR 80 wall sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 7,91 7,2 13,27 7,65 7,91 7,2 7,92 6,05 7,91 7,2 7,89 3,64 1,8 6,45 5,87 10,83 3,64 6,45 5,87 6,45 2,53 6,45 5,87 6,43 0,86 2,1 5,42 4,95 9,04 1,93 5,42 4,95 5,43 1,11 5,42 4,95 5,4-2,4 4,67 4,28 7,53 1,11 4,67 4,28 4,68 0,49 4,67 4,28 4,65-2,7 4,1 3,69 6,37 0,68 4,1 3,69 4,11 0,18 4,1 3,69 4,08-3 3,65 2,69 5,44 0,43 3,65 2,69 3,66 0,03 3,65 2,69 3,64-3,3 3,29 2,04 4,69 0,29 3,29 2,04 3,3-3,29 2,04 3,28-3,6 3 1,6 4,07 0,2 3 1, ,6 2,98-3,9 2,75 1,29 3,56 0,14 2,75 1,29 2,76-2,75 1,29 2,74-4,2 2,54 1,06 3,13 0,1 2,54 1,06 2,55-2,54 1,06 2,53-4,5 2,36 0,88 2,76 0,07 2,36 0,88 2,37-2,36 0,88 2,35-4,8 2,21 0,75 2,45 0,05 2,21 0,75 2,21-2,21 0,75 2,2-5,1 2,07 0,65 2,18 0,04 2,07 0,65 2,08-2,07 0,65 2,06-5,4 1,94 0,56 1,94 0,03 1,94 0,56 1,94-1,94 0,56 1,94-5,7 1,74 0,49 1,74 0,02 1,74 0,49 1,74-1,74 0,49 1,74-6 1,56 0,44 1,56 0,02 1,56 0,44 1,56-1,56 0,44 1,56-6,3 1,41 0,39 1,41 0,01 1,41 0,39 1,41-1,41 0,39 1,41-6,6 1,27 0,35 1,27 0,01 1,27 0,35 1,27-1,27 0,35 1,27-6,9 1,15 0,32 1,15 0,01 1,15 0,32 1,15-1,15 0,32 1,15-7,2 1,05 0,29 1,05-1,05 0,29 1,05-1,05 0,29 1,05-7,5 0,95 0,26 0,95-0,95 0,26 0,95-0,95 0,26 0,95-7,8 0,87 0,24 0,87-0,87 0,24 0,87-0,87 0,24 0,87-8,1 0,8 0,22 0,8-0,8 0,22 0,8-0,8 0,22 0,8-8. Maximal values of wind load (thrust and suction) for ARPANEL S PUR/PIR 100 wall sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 10,31 8,14 15,96 10,31 10,31 8,14 10,32 9,92 10,31 8,14 10,28 9,34 1,8 8,4 6,62 12,82 7,24 8,4 6,62 8,41 6,89 8,4 6,62 8,38 6,36 2,1 7,06 5,57 10,57 5,38 7,06 5,57 7,07 5,06 7,06 5,57 7,04 4,57 2,4 6,07 4,8 8,89 4,16 6,07 4,8 6,08 3,86 6,07 4,8 6,05 3,43 2,7 5,32 4,23 7,59 3,31 5,32 4,23 5,33 3,05 5,32 4,23 5,3 2,29 3 4,73 3,77 6,55 2,7 4,73 3,77 4,74 2,24 4,73 3,77 4,71 1,49 3,3 4,26 3 5,7 2,05 4,26 3 4,27 1,63 4,26 3 4,24 1,01 3,6 3,87 2,31 5 1,58 3,87 2,31 3,88 1,23 3,87 2,31 3,85 0,71 3,9 3,54 1,84 4,42 1,25 3,54 1,84 3,55 0,96 3,54 1,84 3,53 0,51 4,2 3,27 1,49 3,92 1,02 3,27 1,49 3,28 0,76 3,27 1,49 3,25 0,38 4,5 3,04 1,23 3,49 0,84 3,04 1,23 3,05 0,62 3,04 1,23 3,02 0,28 4,8 2,83 1,04 3,13 0,71 2,83 1,04 2,84 0,51 2,83 1,04 2,82 0,22 5,1 2,66 0,88 2,81 0,6 2,66 0,88 2,66 0,43 2,66 0,88 2,64 0,17 5,4 2,5 0,76 2,53 0,52 2,5 0,76 2,51 0,36 2,5 0,76 2,49 0,13 5,7 2,29 0,67 2,29 0,45 2,29 0,67 2,29 0,31 2,29 0,67 2,29 0,11 6 2,07 0,59 2,07 0,4 2,07 0,59 2,07 0,27 2,07 0,59 2,07 0,09 6,3 1,88 0,52 1,88 0,35 1,88 0,52 1,88 0,24 1,88 0,52 1,88 0,07 6,6 1,71 0,46 1,71 0,32 1,71 0,46 1,71 0,21 1,71 0,46 1,71 0,06 6,9 1,56 0,42 1,56 0,28 1,56 0,42 1,56 0,19 1,56 0,42 1,56 0,05 7,2 1,43 0,38 1,43 0,26 1,43 0,38 1,43 0,17 1,43 0,38 1,43 0,04 7,5 1,31 0,34 1,31 0,23 1,31 0,34 1,31 0,15 1,31 0,34 1,31 0,03 7,8 1,2 0,31 1,2 0,21 1,2 0,31 1,2 0,14 1,2 0,31 1,2 0,03 8,1 1,11 0,29 1,11 0,19 1,11 0,29 1,11 0,13 1,11 0,29 1,11 0,02 84 Resistance tables

85 4. Resistance tables 9. Maximal values of wind load (thrust and suction) for ARPANEL SU PUR/PIR 60 wall sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 2,5 4,47 4,22 9,95 2,5 4,47 2,51 9,61 2,5 4,47 0,74 9,1 1,8 2,03 3,02 3,44 7,1 2,03 3,02 2,04 6,8 2,03 3,02 2,02 6,35 2,1 1,71 2,14 2,9 5,29 1,71 2,14 1,71 4,68 1,71 2,14 1,7 3,76 2,4 1,47 1,41 2,5 3,53 1,47 1,41 1,48 3,06 1,47 1,41 1,46 2,36 2,7 1,29 0,96 2,19 2,51 1,29 0,96 1,29 2,14 1,29 0,96 1,28 1,58 3 1,15 0,67 1,96 1,87 1,15 0,67 1,15 1,57 1,15 0,67 1,14 1,12 3,3 1,04 0,48 1,77 1,45 1,04 0,48 1,04 1,2 1,04 0,48 1,03 0,83 3,6 0,94 0,35 1,61 1,15 0,94 0,35 0,95 0,94 0,94 0,35 0,94 0,63 3,9 0,87 0,26 1,48 0,94 0,87 0,26 0,87 0,76 0,87 0,26 0,86 0,5 4,2 0,8 0,19 1,37 0,78 0,8 0,19 0,8 0,63 0,8 0,19 0,79 0,4 4,5 0,74 0,14 1,27 0,66 0,74 0,14 0,75 0,53 0,74 0,14 0,74 0,33 4,8 0,69 0,11 1,19 0,57 0,69 0,11 0,7 0,45 0,69 0,11 0,69 0,27 5,1 0,65 0,08 1,12 0,49 0,65 0,08 0,66 0,39 0,65 0,08 0,65 0,23 5,4 0,61 0,07 1,05 0,43 0,61 0,07 0,62 0,34 0,61 0,07 0,61 0,2 5,7 0,58 0,05 0,99 0,38 0,58 0,05 0,58 0,3 0,58 0,05 0,58 0,17 6 0,55 0,04 0,94 0,34 0,55 0,04 0,55 0,26 0,55 0,04 0,55 0,15 6,3 0,52 0,03 0,84 0,3 0,52 0,03 0,53 0,23 0,52 0,03 0,52 0,13 6,6 0,5 0,02 0,76 0,27 0,5 0,02 0,5 0,21 0,5 0,02 0,49 0,12 6,9 0,48 0,02 0,68 0,25 0,48 0,02 0,48 0,19 0,48 0,02 0,47 0,11 7,2 0,46 0,02 0,62 0,23 0,46 0,02 0,46 0,17 0,46 0,02 0,45 0,09 7,5 0,44 0,01 0,56 0,21 0,44 0,01 0,44 0,16 0,44 0,01 0,43 0,09 7,8 0,42 0,01 0,51 0,19 0,42 0,01 0,42 0,14 0,42 0,01 0,42 0,08 8,1 0,4 0,01 0,47 0,17 0,4 0,01 0,41 0,13 0,4 0,01 0,4 0, Maximal values of wind load (thrust and suction) for ARPANEL SU PUR/PIR 80 wall sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 7,91 7,2 13,27 7,79 7,91 7,2 7,92 6,19 7,91 7,2 7,89 3,78 1,8 6,45 5,87 10,83 3,72 6,45 5,87 6,45 2,61 6,45 5,87 6,43 0,94 2,1 5,42 4,95 9,04 1,98 5,42 4,95 5,43 1,17 5,42 4,95 5,4-2,4 4,67 4,28 7,53 1,15 4,67 4,28 4,68 0,52 4,67 4,28 4,65-2,7 4,1 3,69 6,37 0,7 4,1 3,69 4,11 0,21 4,1 3,69 4,08-3 3,65 2,69 5,44 0,45 3,65 2,69 3,66 0,05 3,65 2,69 3,64-3,3 3,29 2,04 4,69 0,3 3,29 2,04 3,3-3,29 2,04 3,28-3,6 3 1,6 4,07 0,21 3 1, ,6 2,98-3,9 2,75 1,29 3,56 0,15 2,75 1,29 2,76-2,75 1,29 2,74-4,2 2,54 1,06 3,13 0,11 2,54 1,06 2,55-2,54 1,06 2,53-4,5 2,36 0,88 2,76 0,08 2,36 0,88 2,37-2,36 0,88 2,35-4,8 2,21 0,75 2,45 0,06 2,21 0,75 2,21-2,21 0,75 2,2-5,1 2,07 0,65 2,18 0,04 2,07 0,65 2,08-2,07 0,65 2,06-5,4 1,94 0,56 1,94 0,03 1,94 0,56 1,94-1,94 0,56 1,94-5,7 1,74 0,49 1,74 0,03 1,74 0,49 1,74-1,74 0,49 1,74-6 1,56 0,44 1,56 0,02 1,56 0,44 1,56-1,56 0,44 1,56-6,3 1,41 0,39 1,41 0,02 1,41 0,39 1,41-1,41 0,39 1,41-6,6 1,27 0,35 1,27 0,01 1,27 0,35 1,27-1,27 0,35 1,27-6,9 1,15 0,32 1,15 0,01 1,15 0,32 1,15-1,15 0,32 1,15-7,2 1,05 0,29 1,05 0,01 1,05 0,29 1,05-1,05 0,29 1,05-7,5 0,95 0,26 0,95 0,01 0,95 0,26 0,95-0,95 0,26 0,95-7,8 0,87 0,24 0,87-0,87 0,24 0,87-0,87 0,24 0,87-8,1 0,8 0,22 0,8-0,8 0,22 0,8-0,8 0,22 0,8-85 Resistance tables MiWo CH D S/SU Resistance tables

86 4. Resistance tables 11. Maximal values of wind load (thrust and suction) for ARPANEL SU PUR/PIR 100 wall sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 10,31 8,14 15,96 10,31 10,31 8,14 10,32 9,92 10,31 8,14 10,28 9,34 1,8 8,4 6,62 12,82 7,24 8,4 6,62 8,41 6,89 8,4 6,62 8,38 6,36 2,1 7,06 5,57 10,57 5,38 7,06 5,57 7,07 5,06 7,06 5,57 7,04 4,57 2,4 6,07 3,38 8,89 4,16 6,07 3,38 6,08 3,86 6,07 3,38 6,05 3,43 2,7 5,32 2,13 7,59 3,31 5,32 2,13 5,33 3,05 5,32 2,13 5,3 2,65 3 4,73 1,41 6,55 2,7 4,73 1,41 4,74 2,46 4,73 1,41 4,71 1,93 3,3 4,26 0,97 5,7 2,24 4,26 0,97 4,27 2,03 4,26 0,97 4,24 1,43 3,6 3,87 0,7 5 1,89 3,87 0,7 3,88 1,7 3,87 0,7 3,85 1,07 3,9 3,54 0,51 4,42 1,62 3,54 0,51 3,55 1,44 3,54 0,51 3,53 0,82 4,2 3,27 0,39 3,92 1,4 3,27 0,39 3,28 1,24 3,27 0,39 3,25 0,63 4,5 3,04 0,3 3,49 1,22 3,04 0,3 3,05 1,07 3,04 0,3 3,02 0,49 4,8 2,83 0,23 3,13 1,08 2,83 0,23 2,84 0,9 2,83 0,23 2,82 0,39 5,1 2,66 0,19 2,81 0,94 2,66 0,19 2,66 0,76 2,66 0,19 2,64 0,31 5,4 2,5 0,15 2,53 0,81 2,5 0,15 2,51 0,66 2,5 0,15 2,49 0,25 5,7 2,29 0,12 2,29 0,71 2,29 0,12 2,29 0,57 2,29 0,12 2,29 0,2 6 2,07 0,1 2,07 0,63 2,07 0,1 2,07 0,5 2,07 0,1 2,07 0,17 6,3 1,88 0,09 1,88 0,56 1,88 0,09 1,88 0,45 1,88 0,09 1,88 0,14 6,6 1,71 0,07 1,71 0,5 1,71 0,07 1,71 0,4 1,71 0,07 1,71 0,11 6,9 1,56 0,06 1,56 0,45 1,56 0,06 1,56 0,36 1,56 0,06 1,56 0,09 7,2 1,43 0,05 1,43 0,41 1,43 0,05 1,43 0,32 1,43 0,05 1,43 0,08 7,5 1,31 0,05 1,31 0,37 1,31 0,05 1,31 0,29 1,31 0,05 1,31 0,07 7,8 1,2 0,04 1,2 0,34 1,2 0,04 1,2 0,27 1,2 0,04 1,2 0,05 8,1 1,11 0,04 1,11 0,32 1,11 0,04 1,11 0,25 1,11 0,04 1,11 0, Maximal values of wind load (thrust and suction) for ARPANEL S PUR/PIR 40 wall sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 2,68 2,89 4,28 1,99 2,68 2,89 2,68 1,2 2,68 2,89 2,68-1,8 2,2 1,96 3,37 1,06 2,2 1,96 2,21 0,51 2,2 1,96 2,2-2,1 1,87 1,32 2,72 0,64 1,87 1,32 1,87 0,23 1,87 1,32 1,86-2,4 1,62 0,94 2,23 0,42 1,62 0,94 1,62 0,11 1,62 0,94 1,62-2,7 1,43 0,69 1,86 0,29 1,43 0,69 1,44 0,05 1,43 0,69 1,43-3 1,29 0,53 1,56 0,22 1,29 0,53 1,29 0,02 1,29 0,53 1,28-3,3 1,16 0,42 1,32 0,16 1,16 0,42 1,17-1,16 0,42 1,16-3,6 1,06 0,34 1,12 0,13 1,06 0,34 1,07-1,06 0,34 1,06-3,9 0,96 0,28 0,96 0,1 0,96 0,28 0,96-0,96 0,28 0,96-4,2 0,83 0,24 0,83 0,09 0,83 0,24 0,83-0,83 0,24 0,82-4,5 0,72 0,2 0,72 0,07 0,72 0,2 0,72-0,72 0,2 0,69-4,8 0,63 0,17 0,63 0,06 0,63 0,17 0,63-0,63 0,17 0,59-5,1 0,54 0,15 0,55 0,05 0,54 0,15 0,55-0,54 0,15 0,5-5,4 0,47 0,13 0,48 0,05 0,47 0,13 0,48-0,47 0,13 0,43-5,7 0,4 0,12 0,42 0,04 0,4 0,12 0,42-0,4 0,12 0,37-6 0,35 0,11 0,38 0,04 0,35 0,11 0,37-0,35 0,11 0,32-6,3 0,31 0,1 0,33 0,03 0,31 0,1 0,32-0,31 0,1 0,28-6,6 0,27 0,09 0,3 0,03 0,27 0,09 0,28-0,27 0,09 0,23-6,9 0,23 0,08 0,27 0,03 0,23 0,08 0,25-0,23 0,08 0,19-7,2 0,21 0,07 0,24 0,02 0,21 0,07 0,22-0,21 0,07 0,15-7,5 0,18 0,07 0,21 0,02 0,18 0,07 0,19-0,18 0,07 0,12-7,8 0,16 0,06 0,19 0,02 0,16 0,06 0,17-0,16 0,06 0,1-8,1 0,13 0,06 0,17 0,02 0,13 0,06 0,15-0,13 0,06 0,08-86 Resistance tables

87 4. Resistance tables 13. Maximal values of wind load (thrust and suction) for ARPANEL S PUR/PIR 60 wall sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 2,45 4,35 4,14 3,21 2,45 4,35 2,46 2,01 2,45 4,35 0,76 0,21 1,8 2,01 2,95 3,4 1,7 2,01 2,95 2,01 0,87 2,01 2,95 2-2,1 1,7 2,02 2,88 1,02 1,7 2,02 1,7 0,41 1,7 2,02 1,69-2,4 1,47 1,43 2,5 0,67 1,47 1,43 1,48 0,2 1,47 1,43 1,46-2,7 1,3 1,05 2,21 0,46 1,3 1,05 1,3 0,09 1,3 1,05 1,29-3 1,16 0,81 1,98 0,34 1,16 0,81 1,17 0,04 1,16 0,81 1,15-3,3 1,05 0,64 1,79 0,26 1,05 0,64 1,06 0,01 1,05 0,64 1,04-3,6 0,96 0,51 1,64 0,2 0,96 0,51 0,96-0,96 0,51 0,95-3,9 0,88 0,42 1,51 0,16 0,88 0,42 0,89-0,88 0,42 0,88-4,2 0,82 0,36 1,4 0,13 0,82 0,36 0,82-0,82 0,36 0,81-4,5 0,76 0,3 1,3 0,11 0,76 0,3 0,77-0,76 0,3 0,76-4,8 0,71 0,26 1,22 0,1 0,71 0,26 0,72-0,71 0,26 0,71-5,1 0,67 0,23 1,15 0,08 0,67 0,23 0,67-0,67 0,23 0,66-5,4 0,63 0,2 1,06 0,07 0,63 0,2 0,64-0,63 0,2 0,63-5,7 0,6 0,18 0,94 0,06 0,6 0,18 0,6-0,6 0,18 0,59-6 0,57 0,16 0,83 0,06 0,57 0,16 0,57-0,57 0,16 0,56-6,3 0,54 0,14 0,74 0,05 0,54 0,14 0,54-0,54 0,14 0,54-6,6 0,52 0,13 0,66 0,04 0,52 0,13 0,52-0,52 0,13 0,51-6,9 0,49 0,12 0,6 0,04 0,49 0,12 0,5-0,49 0,12 0,49-7,2 0,47 0,11 0,54 0,04 0,47 0,11 0,47-0,47 0,11 0,47-7,5 0,45 0,1 0,48 0,03 0,45 0,1 0,46-0,45 0,1 0,45-7,8 0,43 0,09 0,44 0,03 0,43 0,09 0,44-0,43 0,09 0,4-8,1 0,39 0,08 0,4 0,03 0,39 0,08 0,4-0,39 0,08 0, Maximal values of wind load (thrust and suction) for ARPANEL S PUR/PIR 80 wall sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 7,74 7,2 12,98 5,05 7,74 7,2 7,75 3,45 7,74 7,2 7,72 1,04 1,8 6,34 5,87 10,65 2,67 6,34 5,87 6,35 1,56 6,34 5,87 6,33-2,1 5,37 4,95 9,03 1,59 5,37 4,95 5,38 0,77 5,37 4,95 5,35-2,4 4,65 4,28 7,54 1,04 4,65 4,28 4,66 0,41 4,65 4,28 4,64-2,7 4,11 3,78 6,33 0,72 4,11 3,78 4,12 0,22 4,11 3,78 4,09-3 3,68 2,92 5,37 0,52 3,68 2,92 3,68 0,12 3,68 2,92 3,66-3,3 3,33 2,32 4,58 0,4 3,33 2,32 3,34 0,07 3,33 2,32 3,31-3,6 3,04 1,89 3,94 0,31 3,04 1,89 3,05 0,03 3,04 1,89 3,03-3,9 2,8 1,58 3,41 0,25 2,8 1,58 2,8 0,01 2,8 1,58 2,79-4,2 2,59 1,33 2,97 0,21 2,59 1,33 2,6-2,59 1,33 2,58-4,5 2,42 1,14 2,59 0,17 2,42 1,14 2,42-2,42 1,14 2,4-4,8 2,26 0,99 2,28 0,15 2,26 0,99 2,27-2,26 0,99 2,25-5,1 2,01 0,87 2,01 0,13 2,01 0,87 2,01-2,01 0,87 2,01-5,4 1,78 0,77 1,78 0,11 1,78 0,77 1,78-1,78 0,77 1,78-5,7 1,58 0,68 1,58 0,1 1,58 0,68 1,58-1,58 0,68 1,58-6 1,41 0,61 1,41 0,08 1,41 0,61 1,41-1,41 0,61 1,41-6,3 1,26 0,55 1,26 0,08 1,26 0,55 1,26-1,26 0,55 1,26-6,6 1,13 0,5 1,13 0,07 1,13 0,5 1,13-1,13 0,5 1,13-6,9 1,01 0,46 1,01 0,06 1,01 0,46 1,01-1,01 0,46 1,01-7,2 0,92 0,42 0,92 0,06 0,92 0,42 0,92-0,92 0,42 0,92-7,5 0,83 0,38 0,83 0,05 0,83 0,38 0,83-0,83 0,38 0,83-7,8 0,75 0,35 0,75 0,05 0,75 0,35 0,75-0,75 0,35 0,75-8,1 0,68 0,33 0,68 0,04 0,68 0,33 0,68-0,68 0,33 0,68-87 Resistance tables MiWo CH D S/SU Resistance tables

88 4. Resistance tables 15. Maximal values of wind load (thrust and suction) for ARPANEL S PUR/PIR 100 wall sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 10,05 8,14 16,09 10,47 10,05 8,14 10,06 9,92 10,05 8,14 10,02 9,09 1,8 8,22 6,62 12,94 7,34 8,22 6,62 8,23 6,88 8,22 6,62 8,2 6,18 2,1 6,94 4,25 10,67 5,43 6,94 4,25 6,95 5,05 6,94 4,25 6,92 4,46 2,4 6,01 2,76 8,95 4,18 6,01 2,76 6,02 3,86 6,01 2,76 5,98 2,96 2,7 5,29 1,91 7,61 3,32 5,29 1,91 5,3 2,96 5,29 1,91 5,27 2,03 3 4,73 1,39 6,54 2,7 4,73 1,39 4,74 2,22 4,73 1,39 4,71 1,47 3,3 4,27 1,05 5,66 2,14 4,27 1,05 4,28 1,72 4,27 1,05 4,25 1,1 3,6 3,9 0,82 4,93 1,73 3,9 0,82 3,91 1,38 3,9 0,82 3,88 0,85 3,9 3,58 0,66 4,32 1,42 3,58 0,66 3,59 1,13 3,58 0,66 3,57 0,68 4,2 3,32 0,54 3,8 1,2 3,32 0,54 3,33 0,94 3,32 0,54 3,3 0,56 4,5 3,09 0,45 3,36 1,02 3,09 0,45 3,1 0,8 3,09 0,45 3,07 0,46 4,8 2,89 0,38 2,98 0,88 2,89 0,38 2,9 0,68 2,89 0,38 2,87 0,39 5,1 2,66 0,33 2,66 0,77 2,66 0,33 2,66 0,59 2,66 0,33 2,66 0,33 5,4 2,37 0,29 2,37 0,68 2,37 0,29 2,37 0,52 2,37 0,29 2,37 0,29 5,7 2,13 0,25 2,13 0,6 2,13 0,25 2,13 0,46 2,13 0,25 2,13 0,25 6 1,91 0,22 1,91 0,54 1,91 0,22 1,91 0,41 1,91 0,22 1,91 0,22 6,3 1,72 0,2 1,72 0,48 1,72 0,2 1,72 0,37 1,72 0,2 1,72 0,2 6,6 1,56 0,18 1,56 0,44 1,56 0,18 1,56 0,33 1,56 0,18 1,56 0,18 6,9 1,41 0,16 1,41 0,4 1,41 0,16 1,41 0,3 1,41 0,16 1,41 0,16 7,2 1,28 0,15 1,28 0,36 1,28 0,15 1,28 0,27 1,28 0,15 1,28 0,14 7,5 1,17 0,13 1,17 0,33 1,17 0,13 1,17 0,25 1,17 0,13 1,17 0,13 7,8 1,07 0,12 1,07 0,31 1,07 0,12 1,07 0,23 1,07 0,12 1,07 0,12 8,1 0,98 0,11 0,98 0,28 0,98 0,11 0,98 0,21 0,98 0,11 0,98 0, Maximal values of wind load (thrust and suction) for ARPANEL S PUR/PIR 60 wall sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 2,45 4,35 4,14 10,21 2,45 4,35 2,46 9,79 2,45 4,35 0,76 9,15 1,8 2,01 2,95 3,4 7,22 2,01 2,95 2,01 6,66 2,01 2,95 2 5,41 2,1 1,7 2,02 2,88 4,98 1,7 2,02 1,7 4,37 1,7 2,02 1,69 3,45 2,4 1,47 1,43 2,5 3,55 1,47 1,43 1,48 3,09 1,47 1,43 1,46 2,38 2,7 1,3 1,05 2,21 2,67 1,3 1,05 1,3 2,3 1,3 1,05 1,29 1,74 3 1,16 0,81 1,98 2,08 1,16 0,81 1,17 1,78 1,16 0,81 1,15 1,33 3,3 1,05 0,64 1,79 1,67 1,05 0,64 1,06 1,42 1,05 0,64 1,04 1,05 3,6 0,96 0,51 1,64 1,37 0,96 0,51 0,96 1,16 0,96 0,51 0,95 0,85 3,9 0,88 0,42 1,51 1,15 0,88 0,42 0,89 0,97 0,88 0,42 0,88 0,7 4,2 0,82 0,36 1,4 0,97 0,82 0,36 0,82 0,82 0,82 0,36 0,81 0,59 4,5 0,76 0,3 1,3 0,84 0,76 0,3 0,77 0,71 0,76 0,3 0,76 0,51 4,8 0,71 0,26 1,22 0,73 0,71 0,26 0,72 0,61 0,71 0,26 0,71 0,44 5,1 0,67 0,23 1,15 0,64 0,67 0,23 0,67 0,54 0,67 0,23 0,66 0,38 5,4 0,63 0,2 1,06 0,57 0,63 0,2 0,64 0,48 0,63 0,2 0,63 0,34 5,7 0,6 0,18 0,94 0,51 0,6 0,18 0,6 0,42 0,6 0,18 0,59 0,3 6 0,57 0,16 0,83 0,45 0,57 0,16 0,57 0,38 0,57 0,16 0,56 0,27 6,3 0,54 0,14 0,74 0,41 0,54 0,14 0,54 0,34 0,54 0,14 0,54 0,24 6,6 0,52 0,13 0,66 0,37 0,52 0,13 0,52 0,31 0,52 0,13 0,51 0,22 6,9 0,49 0,12 0,6 0,34 0,49 0,12 0,5 0,28 0,49 0,12 0,49 0,2 7,2 0,47 0,11 0,54 0,31 0,47 0,11 0,47 0,26 0,47 0,11 0,47 0,18 7,5 0,45 0,1 0,48 0,29 0,45 0,1 0,46 0,24 0,45 0,1 0,45 0,17 7,8 0,43 0,09 0,44 0,26 0,43 0,09 0,44 0,22 0,43 0,09 0,4 0,15 8,1 0,39 0,08 0,4 0,24 0,39 0,08 0,4 0,2 0,39 0,08 0,36 0,14 88 Resistance tables

89 4. Resistance tables 17. Maximal values of wind load (thrust and suction) for ARPANEL S PUR/PIR 80 wall sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 7,74 7,2 12,98 5,16 7,74 7,2 7,75 3,56 7,74 7,2 7,72 1,16 1,8 6,34 5,87 10,65 2,74 6,34 5,87 6,35 1,63 6,34 5,87 6,33-2,1 5,37 4,95 9,03 1,64 5,37 4,95 5,38 0,82 5,37 4,95 5,35-2,4 4,65 4,28 7,54 1,07 4,65 4,28 4,66 0,44 4,65 4,28 4,64-2,7 4,11 3,78 6,33 0,74 4,11 3,78 4,12 0,25 4,11 3,78 4,09-3 3,68 2,92 5,37 0,54 3,68 2,92 3,68 0,14 3,68 2,92 3,66-3,3 3,33 2,32 4,58 0,41 3,33 2,32 3,34 0,08 3,33 2,32 3,31-3,6 3,04 1,89 3,94 0,33 3,04 1,89 3,05 0,05 3,04 1,89 3,03-3,9 2,8 1,58 3,41 0,26 2,8 1,58 2,8 0,02 2,8 1,58 2,79-4,2 2,59 1,33 2,97 0,22 2,59 1,33 2,6 0,01 2,59 1,33 2,58-4,5 2,42 1,14 2,59 0,18 2,42 1,14 2,42-2,42 1,14 2,4-4,8 2,26 0,99 2,28 0,15 2,26 0,99 2,27-2,26 0,99 2,25-5,1 2,01 0,87 2,01 0,13 2,01 0,87 2,01-2,01 0,87 2,01-5,4 1,78 0,77 1,78 0,11 1,78 0,77 1,78-1,78 0,77 1,78-5,7 1,58 0,68 1,58 0,1 1,58 0,68 1,58-1,58 0,68 1,58-6 1,41 0,61 1,41 0,09 1,41 0,61 1,41-1,41 0,61 1,41-6,3 1,26 0,55 1,26 0,08 1,26 0,55 1,26-1,26 0,55 1,26-6,6 1,13 0,5 1,13 0,07 1,13 0,5 1,13-1,13 0,5 1,13-6,9 1,01 0,46 1,01 0,06 1,01 0,46 1,01-1,01 0,46 1,01-7,2 0,92 0,42 0,92 0,06 0,92 0,42 0,92-0,92 0,42 0,92-7,5 0,83 0,38 0,83 0,05 0,83 0,38 0,83-0,83 0,38 0,83-7,8 0,75 0,35 0,75 0,05 0,75 0,35 0,75-0,75 0,35 0,75-8,1 0,68 0,33 0,68 0,05 0,68 0,33 0,68-0,68 0,33 0, Maximal values of wind load (thrust and suction) for ARPANEL S PUR/PIR 100 wall sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 10,05 8,14 16,09 10,47 10,05 8,14 10,06 9,92 10,05 8,14 10,02 9,09 1,8 8,22 6,62 12,94 7,34 8,22 6,62 8,23 6,88 8,22 6,62 8,2 6,18 2,1 6,94 4,25 10,67 5,43 6,94 4,25 6,95 5,05 6,94 4,25 6,92 4,46 2,4 6,01 2,76 8,95 4,18 6,01 2,76 6,02 3,86 6,01 2,76 5,98 3,36 2,7 5,29 1,91 7,61 3,32 5,29 1,91 5,3 3,04 5,29 1,91 5,27 2,51 3 4,73 1,39 6,54 2,7 4,73 1,39 4,74 2,46 4,73 1,39 4,71 1,91 3,3 4,27 1,05 5,66 2,24 4,27 1,05 4,28 2,03 4,27 1,05 4,25 1,5 3,6 3,9 0,82 4,93 1,88 3,9 0,82 3,91 1,7 3,9 0,82 3,88 1,2 3,9 3,58 0,66 4,32 1,61 3,58 0,66 3,59 1,45 3,58 0,66 3,57 0,98 4,2 3,32 0,54 3,8 1,39 3,32 0,54 3,33 1,25 3,32 0,54 3,3 0,82 4,5 3,09 0,45 3,36 1,21 3,09 0,45 3,1 1,09 3,09 0,45 3,07 0,69 4,8 2,89 0,38 2,98 1,07 2,89 0,38 2,9 0,96 2,89 0,38 2,87 0,59 5,1 2,66 0,33 2,66 0,94 2,66 0,33 2,66 0,85 2,66 0,33 2,66 0,51 5,4 2,37 0,29 2,37 0,84 2,37 0,29 2,37 0,75 2,37 0,29 2,37 0,45 5,7 2,13 0,25 2,13 0,76 2,13 0,25 2,13 0,68 2,13 0,25 2,13 0,4 6 1,91 0,22 1,91 0,68 1,91 0,22 1,91 0,61 1,91 0,22 1,91 0,35 6,3 1,72 0,2 1,72 0,62 1,72 0,2 1,72 0,55 1,72 0,2 1,72 0,31 6,6 1,56 0,18 1,56 0,57 1,56 0,18 1,56 0,5 1,56 0,18 1,56 0,28 6,9 1,41 0,16 1,41 0,52 1,41 0,16 1,41 0,46 1,41 0,16 1,41 0,26 7,2 1,28 0,15 1,28 0,48 1,28 0,15 1,28 0,42 1,28 0,15 1,28 0,23 7,5 1,17 0,13 1,17 0,44 1,17 0,13 1,17 0,39 1,17 0,13 1,17 0,21 7,8 1,07 0,12 1,07 0,41 1,07 0,12 1,07 0,36 1,07 0,12 1,07 0,2 8,1 0,98 0,11 0,98 0,38 0,98 0,11 0,98 0,33 0,98 0,11 0,98 0,18 89 Resistance tables MiWo CH D S/SU Resistance tables

90 4. Resistance tables 19. Maximal values of wind load (thrust and suction) and snow load (thrust) for ARPANEL D PUR/PIR 40/80 roof sandwich panels, single-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 4,57 3,99 6,91 6,09 4,57 3,99 6,91 6,09 4,57 3,99 6,91 6,09 1,8 3,15 2,74 4,82 4,26 3,15 2,74 4,82 4,26 3,15 2,74 4,82 4,26 2,1 2,3 1,99 3,57 3,15 2,3 1,99 3,57 3,15 2,3 1,99 3,57 3,15 2,4 1,74 1,5 2,76 2,44 1,74 1,5 2,76 2,44 1,74 1,5 2,76 2,44 2,7 1,36 1,17 2,2 1,95 1,36 1,17 2,2 1,95 1,36 1,17 2,2 1,95 3 1,09 0,93 1,8 1,6 1,09 0,93 1,8 1,6 1,09 0,93 1,8 1,6 3,3 0,89 0,75 1,51 1,34 0,89 0,75 1,51 1,34 0,89 0,75 1,51 1,34 3,6 0,74 0,62 1,28 1,14 0,74 0,62 1,28 1,14 0,74 0,62 1,28 1,14 3,9 0,62 0,52 1,11 0,99 0,62 0,52 1,11 0,99 0,62 0,52 1,11 0,99 4,2 0,53 0,43 0,97 0,87 0,53 0,43 0,97 0,87 0,53 0,43 0,97 0,87 4,5 0,45 0,37 0,86 0,77 0,45 0,37 0,86 0,77 0,45 0,37 0,86 0,77 4,8 0,39 0,31 0,77 0,69 0,39 0,31 0,77 0,69 0,39 0,31 0,77 0,69 5,1 0,34 0,26 0,69 0,62 0,34 0,26 0,69 0,62 0,34 0,26 0,69 0,62 5,4 0,29 0,23 0,63 0,56 0,29 0,23 0,63 0,56 0,29 0,23 0,63 0,56 5,7 0,26 0,19 0,57 0,52 0,26 0,19 0,57 0,52 0,26 0,19 0,55 0,52 6 0,22 0,17 0,53 0,48 0,22 0,17 0,53 0,48 0,22 0,17 0,45 0,48 6,3 0,19 0,14 0,49 0,44 0,19 0,14 0,49 0,44 0,19 0,14 0,37 0,44 6,6 0,1 0,12 0,45 0,41 0,1 0,12 0,45 0,41 0,1 0,12 0,31 0,41 6,9 0,03 0,11 0,42 0,39 0,03 0,11 0,42 0,39 0,03 0,11 0,26 0,39 7,2-0,09-0,36-0,09-0,36-0,09-0,36 7,5-0,08-0,34-0,08-0,34-0,08-0,34 7,8-0,06-0,32-0,06-0,32-0,06-0,32 8,1-0,05-0,31-0,05-0,31-0,05-0, Maximal values of wind load (thrust and suction) and snow load (thrust) for ARPANEL D PUR/PIR 60/100 roof sandwich panels, single-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 5,13 4,49 7,76 6,84 5,13 4,49 7,76 6,84 5,13 4,49 7,76 6,84 1,8 3,54 3,08 5,42 4,78 3,54 3,08 5,42 4,78 3,54 3,08 5,42 4,78 2,1 2,58 2,24 4,01 3,54 2,58 2,24 4,01 3,54 2,58 2,24 4,01 3,54 2,4 1,96 1,69 3,09 2,73 1,96 1,69 3,09 2,73 1,96 1,69 3,09 2,73 2,7 1,53 1,32 2,47 2,18 1,53 1,32 2,47 2,18 1,53 1,32 2,47 2,18 3 1,23 1,05 2,02 1,79 1,23 1,05 2,02 1,79 1,23 1,05 2,02 1,79 3,3 1 0,85 1,69 1,5 1 0,85 1,69 1,5 1 0,85 1,69 1,5 3,6 0,83 0,7 1,44 1,28 0,83 0,7 1,44 1,28 0,83 0,7 1,44 1,28 3,9 0,7 0,58 1,24 1,11 0,7 0,58 1,24 1,11 0,7 0,58 1,24 1,11 4,2 0,59 0,49 1,09 0,97 0,59 0,49 1,09 0,97 0,59 0,49 1,09 0,97 4,5 0,51 0,41 0,96 0,86 0,51 0,41 0,96 0,86 0,51 0,41 0,96 0,86 4,8 0,44 0,35 0,86 0,77 0,44 0,35 0,86 0,77 0,44 0,35 0,86 0,77 5,1 0,38 0,3 0,77 0,69 0,38 0,3 0,77 0,69 0,38 0,3 0,77 0,69 5,4 0,33 0,26 0,7 0,63 0,33 0,26 0,7 0,63 0,33 0,26 0,7 0,63 5,7 0,29 0,22 0,64 0,58 0,29 0,22 0,64 0,58 0,29 0,22 0,64 0,58 6 0,26 0,19 0,59 0,53 0,26 0,19 0,59 0,53 0,26 0,19 0,59 0,53 6,3 0,23 0,17 0,54 0,49 0,23 0,17 0,54 0,49 0,23 0,17 0,54 0,49 6,6 0,2 0,14 0,51 0,46 0,2 0,14 0,51 0,46 0,2 0,14 0,51 0,46 6,9 0,18 0,12 0,47 0,43 0,18 0,12 0,47 0,43 0,18 0,12 0,47 0,43 7,2 0,16 0,1 0,44 0,4 0,16 0,1 0,44 0,4 0,16 0,1 0,44 0,4 7,5 0,14 0,09 0,42 0,38 0,14 0,09 0,42 0,38 0,14 0,09 0,42 0,38 7,8 0,12 0,08 0,39 0,36 0,12 0,08 0,39 0,36 0,12 0,08 0,39 0,36 8,1 0,11 0,06 0,37 0,34 0,11 0,06 0,37 0,34 0,11 0,06 0,37 0,34 90 Resistance tables

91 4. Resistance tables 21. Maximal values of wind load (thrust and suction) and snow load (thrust) for ARPANEL D PUR/PIR 80/120 roof sandwich panels, single-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 8,59 6,71 10,84 9,56 8,59 6,71 10,84 9,56 8,59 6,71 10,84 9,56 1,8 7,15 5,57 7,56 6,67 7,15 5,57 7,56 6,67 7,15 5,57 7,56 6,67 2,1 5,26 4,59 5,58 4,93 5,26 4,59 5,58 4,93 5,26 4,59 5,58 4,93 2,4 4,01 3,49 4,3 3,8 4,01 3,49 4,3 3,8 4,01 3,49 4,3 3,8 2,7 3,15 2,74 3,42 3,03 3,15 2,74 3,42 3,03 3,15 2,74 3,42 3,03 3 2,54 2,2 2,8 2,47 2,54 2,2 2,8 2,47 2,54 2,2 2,8 2,47 3,3 2,09 1,8 2,33 2,07 2,09 1,8 2,33 2,07 2,09 1,8 2,33 2,07 3,6 1,74 1,5 1,98 1,76 1,74 1,5 1,98 1,76 1,74 1,5 1,98 1,76 3,9 1,47 1,26 1,7 1,51 1,47 1,26 1,7 1,51 1,47 1,26 1,7 1,51 4,2 1,26 1,07 1,49 1,32 1,26 1,07 1,49 1,32 1,26 1,07 1,49 1,32 4,5 1,09 0,92 1,31 1,17 1,09 0,92 1,31 1,17 1,09 0,92 1,31 1,17 4,8 0,95 0,8 1,16 1,04 0,95 0,8 1,16 1,04 0,95 0,8 1,16 1,04 5,1 0,83 0,69 1,05 0,93 0,83 0,69 1,05 0,93 0,83 0,69 1,05 0,93 5,4 0,73 0,61 0,95 0,85 0,73 0,61 0,95 0,85 0,73 0,61 0,95 0,85 5,7 0,65 0,54 0,86 0,77 0,65 0,54 0,86 0,77 0,65 0,54 0,86 0,77 6 0,58 0,47 0,79 0,71 0,58 0,47 0,79 0,71 0,58 0,47 0,79 0,71 6,3 0,52 0,42 0,73 0,65 0,52 0,42 0,73 0,65 0,52 0,42 0,73 0,65 6,6 0,47 0,37 0,67 0,61 0,47 0,37 0,67 0,61 0,47 0,37 0,67 0,61 6,9 0,42 0,33 0,63 0,56 0,42 0,33 0,63 0,56 0,42 0,33 0,63 0,56 7,2 0,38 0,3 0,58 0,53 0,38 0,3 0,58 0,53 0,38 0,3 0,58 0,53 7,5 0,34 0,27 0,55 0,5 0,34 0,27 0,55 0,5 0,34 0,27 0,55 0,5 7,8 0,31 0,24 0,52 0,47 0,31 0,24 0,52 0,47 0,31 0,24 0,52 0,47 8,1 0,28 0,21 0,49 0,44 0,28 0,21 0,49 0,44 0,28 0,21 0,49 0, Maximal values of wind load (thrust and suction) and snow load (thrust) for ARPANEL D PUR/PIR 100/140 roof sandwich panels, single-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 8,98 7,01 12,7 11,19 8,98 7,01 12,7 11,19 8,98 7,01 12,7 11,19 1,8 7,47 5,83 8,85 7,8 7,47 5,83 8,85 7,8 7,47 5,83 8,85 7,8 2,1 6,19 4,98 6,53 5,76 6,19 4,98 6,53 5,76 6,19 4,98 6,53 5,76 2,4 4,72 4,12 5,03 4,44 4,72 4,12 5,03 4,44 4,72 4,12 5,03 4,44 2,7 3,71 3,23 4 3,54 3,71 3,23 4 3,54 3,71 3,23 4 3,54 3 2,99 2,6 3,26 2,89 2,99 2,6 3,26 2,89 2,99 2,6 3,26 2,89 3,3 2,46 2,13 2,72 2,41 2,46 2,13 2,72 2,41 2,46 2,13 2,72 2,41 3,6 2,06 1,77 2,31 2,05 2,06 1,77 2,31 2,05 2,06 1,77 2,31 2,05 3,9 1,74 1,49 1,98 1,76 1,74 1,49 1,98 1,76 1,74 1,49 1,98 1,76 4,2 1,49 1,27 1,73 1,54 1,49 1,27 1,73 1,54 1,49 1,27 1,73 1,54 4,5 1,29 1,09 1,52 1,35 1,29 1,09 1,52 1,35 1,29 1,09 1,52 1,35 4,8 1,12 0,95 1,35 1,21 1,12 0,95 1,35 1,21 1,12 0,95 1,35 1,21 5,1 0,98 0,83 1,21 1,08 0,98 0,83 1,21 1,08 0,98 0,83 1,21 1,08 5,4 0,87 0,73 1,1 0,98 0,87 0,73 1,1 0,98 0,87 0,73 1,1 0,98 5,7 0,77 0,64 1 0,89 0,77 0,64 1 0,89 0,77 0,64 1 0,89 6 0,69 0,57 0,91 0,82 0,69 0,57 0,91 0,82 0,69 0,57 0,91 0,82 6,3 0,62 0,51 0,84 0,75 0,62 0,51 0,84 0,75 0,62 0,51 0,84 0,75 6,6 0,56 0,45 0,78 0,7 0,56 0,45 0,78 0,7 0,56 0,45 0,78 0,7 6,9 0,5 0,4 0,72 0,65 0,5 0,4 0,72 0,65 0,5 0,4 0,72 0,65 7,2 0,45 0,36 0,67 0,61 0,45 0,36 0,67 0,61 0,45 0,36 0,67 0,61 7,5 0,41 0,33 0,63 0,57 0,41 0,33 0,63 0,57 0,41 0,33 0,63 0,57 7,8 0,38 0,29 0,59 0,54 0,38 0,29 0,59 0,54 0,38 0,29 0,59 0,54 8,1 0,34 0,26 0,56 0,51 0,34 0,26 0,56 0,51 0,34 0,26 0,56 0,51 91 Resistance tables MiWo CH D S/SU Resistance tables

92 4. Resistance tables 23. Maximal values of wind load (thrust and suction) and snow load (thrust) for ARPANEL D PUR/PIR 120/160 roof sandwich panels, single-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 8,98 7,01 13,55 11,94 8,98 7,01 13,55 11,94 8,98 7,01 13,55 11,94 1,8 7,47 5,82 9,44 8,33 7,47 5,82 9,44 8,33 7,47 5,82 9,44 8,33 2,1 6,39 4,97 6,97 6,15 6,39 4,97 6,97 6,15 6,39 4,97 6,97 6,15 2,4 5,57 4,34 5,36 4,74 5,57 4,34 5,36 4,74 5,57 4,34 5,36 4,74 2,7 4,38 3,82 4,27 3,77 4,38 3,82 4,27 3,77 4,38 3,82 4,27 3,77 3 3,53 3,07 3,48 3,08 3,53 3,07 3,48 3,08 3,53 3,07 3,48 3,08 3,3 2,91 2,52 2,9 2,57 2,91 2,52 2,9 2,57 2,91 2,52 2,9 2,57 3,6 2,43 2,1 2,46 2,18 2,43 2,1 2,46 2,18 2,43 2,1 2,46 2,18 3,9 2,06 1,77 2,12 1,88 2,06 1,77 2,12 1,88 2,06 1,77 2,12 1,88 4,2 1,76 1,51 1,84 1,64 1,76 1,51 1,84 1,64 1,76 1,51 1,84 1,64 4,5 1,52 1,3 1,62 1,44 1,52 1,3 1,62 1,44 1,52 1,3 1,62 1,44 4,8 1,33 1,13 1,44 1,29 1,33 1,13 1,44 1,29 1,33 1,13 1,44 1,29 5,1 1,17 0,99 1,29 1,15 1,17 0,99 1,29 1,15 1,17 0,99 1,29 1,15 5,4 1,03 0,87 1,17 1,04 1,03 0,87 1,17 1,04 1,03 0,87 1,17 1,04 5,7 0,92 0,77 1,06 0,95 0,92 0,77 1,06 0,95 0,92 0,77 1,06 0,95 6 0,82 0,68 0,97 0,87 0,82 0,68 0,97 0,87 0,82 0,68 0,97 0,87 6,3 0,74 0,61 0,9 0,8 0,74 0,61 0,9 0,8 0,74 0,61 0,9 0,8 6,6 0,66 0,54 0,83 0,74 0,66 0,54 0,83 0,74 0,66 0,54 0,83 0,74 6,9 0,6 0,49 0,77 0,69 0,6 0,49 0,77 0,69 0,6 0,49 0,77 0,69 7,2 0,54 0,44 0,72 0,65 0,54 0,44 0,72 0,65 0,54 0,44 0,72 0,65 7,5 0,5 0,4 0,67 0,61 0,5 0,4 0,67 0,61 0,5 0,4 0,67 0,61 7,8 0,45 0,36 0,63 0,57 0,45 0,36 0,63 0,57 0,45 0,36 0,63 0,57 8,1 0,41 0,32 0,59 0,54 0,41 0,32 0,59 0,54 0,41 0,32 0,59 0, Maximal values of wind load (thrust and suction) and snow load (thrust) for ARPANEL D PUR/PIR 40/80 roof sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 3 2,61 4,27 3,56 3 2,61 4,27 3,56 3 2,61 4,27 3,56 1,8 2,27 1,97 3,16 2,54 2,27 1,97 3,16 2,54 2,27 1,81 3,16 2,54 2,1 1,84 1,59 2,49 1,94 1,84 1,59 2,49 1,94 1,84-2,49-2,4 1,55 1,33 2,06 1,54 1,55 0,33 2,06 1,54 1,55-2,06-2,7 1,35-1,77-1,35-1,77-1,35-1,77-3 1,19-1,54-1,19-1, ,3 1,05-1,37-1,05-1, ,6 0,85-1,23-0,85-0, ,9 0,34-1,11-0,34-0, ,2 0,1-0,81-0,1-0, , Resistance tables

93 4. Resistance tables 25. Maximal values of wind load (thrust and suction) and snow load (thrust) for ARPANEL D PUR/PIR 60/100 roof sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 3,15 2,74 4,57 3,86 3,15 2,74 4,57 3,86 3,15 2,74 4,57 3,86 1,8 2,3 1,99 3,29 2,7 2,3 1,99 3,29 2,7 2,3 1,99 3,29 2,7 2,1 1,81 1,56 2,52 2 1,81 1,56 2,52 2 1,81 1,56 2,52 2 2,4 1,49 1,28 2,03 1,54 1,49 1,28 2,03 1,54 1,49-2,03-2,7 1,27 1,09 1,7 0,53 1,27 0,82 1,7 0,53 1,27-1,7-3 1,11-1,46-1,11-1,46-1,11-1,46-3,3 0,99-1,28-0,99-1,28-0,73-1,28-3,6 0,89-1,14-0,89-1, ,9 0,55-1,03-0,55-1, , Maximal values of wind load (thrust and suction) and snow load (thrust) for ARPANEL D PUR/PIR 80/120 roof sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 4,43 3,86 6,31 5,43 4,43 3,86 6,31 5,43 4,43 3,86 6,31 5,43 1,8 3,37 2,93 4,49 3,81 3,37 2,93 4,49 3,81 3,37 2,93 4,49 3,81 2,1 2,8 2,43 3,41 2,83 2,8 2,43 3,41 2,83 2,8 2,35 3,41 2,83 2,4 2,54 2,2 2,72 2,2 2,54 2,1 2,72 2,2 2,54 0,69 2,72 2,2 2,7 2,34 2,02 2,25 1,76 2,34 0,97 2,25 1,76 2,27-2,25-3 2,03 1,47 1,91 1,36 2,03-1,91-1,36-1,91-3,3 1,8 0,75 1,67 0,24 1,8-1,67-0,4-1,67-3,6 1,61-1,48-1,61-1, ,9 1,47-1,33-1,47-1, ,2 1,34-1,21-1,34-1, ,5 1-1, ,8 0,15-1, , Maximal values of wind load (thrust and suction) and snow load (thrust) for ARPANEL D PUR/PIR 100/140 roof sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 6,86 5,35 7,31 6,33 6,86 5,35 7,31 6,33 6,86 5,35 7,31 6,33 1,8 5,08 4,43 5,18 4,43 5,08 4,43 5,18 4,43 5,08 4,43 5,18 4,43 2,1 3,86 3,36 3,9 3,28 3,86 3,36 3,9 3,28 3,86 3,36 3,9 3,28 2,4 3,08 2,67 3,07 2,54 3,08 2,67 3,07 2,54 3,08 2,67 3,07 2,54 2,7 2,56 2,21 2,51 2,03 2,56 2,21 2,51 2,03 2,56 2,21 2,51 2,03 3 2,19 1,89 2,12 1,41 2,19 1,89 2,12 1,41 2,19 1,89 2,12 1,41 3,3 1,92 1,65 1,83 0,52 1,92 1,65 1,83 0,52 1,92 1,65 1,83 0,52 3,6 1,71-1,61-1,71-1,61-1,71-1,61-3,9 1,55-1,44-1,55-1,44-1,55-1,44-4,2 1,41-1,3-1,41-1,3-1,41-1,3-4,5 1,3-1,19-1,3-1,19-1,3-1,19-4, MiWo CH D S/SU 93 Resistance tables Resistance tables

94 4. Resistance tables 28. Maximal values of wind load (thrust and suction) and snow load (thrust) for ARPANEL D PUR/PIR 120/160 roof sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 6,82 5,31 7,75 6,74 6,82 5,31 7,75 6,74 6,82 5,31 7,75 6,74 1,8 5,73 4,46 5,46 4,7 5,73 4,46 5,46 4,7 5,73 4,46 5,46 4,7 2,1 4,42 3,85 4,09 3,47 4,42 3,85 4,09 3,47 4,42 3,85 4,09 3,47 2,4 3,49 3,03 3,2 2,67 3,49 3,03 3,2 2,67 3,49 3,03 3,2 2,67 2,7 2,87 2,48 2,6 2,13 2,87 2,48 2,6 2,13 2,87 2,48 2,6 2,13 3 2,43 2,09 2,17 1,73 2,43 2,09 2,17 1,73 2,43 2,09 2,17 1,73 3,3 2,1 1,81 1,85 1,43 2,1 1,81 1,85 1,43 2,1 1,81 1,85 1,43 3,6 1,86 1,6 1,62 0,66 1,86 1,6 1,62 0,66 1,86 1,6 1,62 0,66 3,9 1,67-1,43-1,67-1,43-1,67-1,43-4,2 1,52-1,28-1,52-1,28-1,52-1,28-4,5 1,39-1,17-1,39-1,17-1,39-1,17-4,8 1,29-1,07-1,29-1,07-1,29-1,07-5,1 1,2-0,99-1,2-0,99-1,2-0,99-5, Maximal values of wind load (thrust and suction) and snow load (thrust) for ARPANEL D PUR/PIR 40/80 roof sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 2,6 2,26 3,08 2,04 2,6 2,15 3,08 2,04 2,6-3,08-1,8 2,3 1,97 2,5 0,8 2,3 0,38 2,5 0,8 2,04-2,5-2,1 2,16-2,18-2,16-2,18-1,21-2,18-2,4 1,89-1,87-1,89-1, ,7 1,62-1,57-1,62-1, ,39-1,35-1,39-1, ,3 0,92-1,19-0,92-0, ,6 0,56-1,06-0,56-0, ,9 0,35-0,96-0,35-0, ,2 0,23-0,86-0,23-0, ,5 0,14-0,74-0,14-0, ,8 0,08-0,64-0,08-0, ,1 0,04-0,56-0,04-0, ,4 0,01-0,5-0,01-0, , Maximal values of wind load (thrust and suction) and snow load (thrust) for ARPANEL D PUR/PIR 60/100 roof sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 2,37 2,05 2,96 2,16 2,37 2,05 2,96 2,16 2,37 1,25 2,96 2,16 1,8 1,96 1,7 2,23 0,96 1,96 0,92 2,23 0,96 1,93-2,23-2,1 1,76-1,81-1,76-1,81-0,94-1,81-2,4 1,64-1,38-1,38-1,38-0,26-1,38-2,7 1, , ,36-0,72-0,7-0, ,3 0,71-0,52-0,5-0, ,6 0,12-0,38-0,12-0, , Resistance tables

95 4. Resistance tables 31. Maximal values of wind load (thrust and suction) and snow load (thrust) for ARPANEL D PUR/PIR 80/120 roof sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 3,7 3,22 4,01 3,17 3,7 3,22 4,01 3,17 3,7 2,94 4,01 3,17 1,8 3,27 2,84 2,98 2,19 3,27 2,16 2,98 2,19 3,27 0,12 2,98 2,19 2,1 2,92 2,19 2,37 1,31 2,92 0,37 2,37 1,31 2,12-2,37-2,4 2,64 1,14 2 0,46 2, , ,7 2,48-1,75-2,48-1, ,39-1,45-2,39-1, ,3 2,2-1,18-2,2-1, ,6 1,97-0,97-1,97-0, ,9 0,8-0, ,2 0,28-0, ,5 0,04-0, , Maximal values of wind load (thrust and suction) and snow load (thrust) for ARPANEL D PUR/PIR 100/140 roof sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 4,74 4,13 4,55 3,7 4,74 4,13 4,55 3,7 4,74 4,13 4,55 3,7 1,8 3,62 3,15 3,31 2,56 3,62 3,15 3,31 2,56 3,62 3,15 3,31 2,56 2,1 3 2,6 2,58 1,86 3 2,6 2,58 1,86 3 2,6 2,58 1,86 2,4 2,63 2,28 2,12 0,51 2,63 2,28 2,12 0,51 2,63 1,64 2,12 0,51 2,7 2,41-1,82-2,41-1,82-2,41-1,82-3 2,27-1,6-2,27-1,6-2,27-1,6-3,3 2,18-1,33-2,18-1,33-2,06-1,33-3,6 2,09-1,08-2,09-1,08-1,7-1,08-3,9 0,1-0,88-0,1-0,88-0,1-0,88-4, Maximal values of wind load (thrust and suction) and snow load (thrust) for ARPANEL D PUR/PIR 120/160 roof sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 5,36 4,68 4,74 3,92 5,36 4,68 4,74 3,92 5,36 4,68 4,74 3,92 1,8 4 3,48 3,4 2,69 4 3,48 3,4 2,69 4 3,48 3,4 2,69 2,1 3,23 2,8 2,6 1,94 3,23 2,8 2,6 1,94 3,23 2,8 2,6 1,94 2,4 2,76 2,39 2,09 1,29 2,76 2,39 2,09 1,29 2,76 2,39 2,09 1,29 2,7 2,47 2,13 1,75 0,33 2,47 2,13 1,75 0,33 2,47 1,43 1,75 0,33 3 2,28-1,51-2,28-1,51-2,28-1,51-3,3 2,16-1,26-2,16-1,26-2,16-1,26-3,6 2,08-0,99-2,08-0,99-2,01-0,99-3,9 2,02-0,77-2,02-0,77-1,67-0,77-4,2 0,98-0,59-0,98-0,59-0,98-0,59-4, S/SU D CH MiWo 95 Resistance tables Resistance tables

96 4. Resistance tables 34. Maximal values of wind load (thrust and suction) for Arpanel CH PUR/PIR 120 sandwich panels, single-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 11,54 8,47 13,55 14,68 11,54 8,47 13,55 14,68 11,54 8,47 13,55 14,68 1,8 9,62 7,05 10,91 10,19 9,62 7,05 10,91 10,19 9,62 7,05 10,91 10,19 2,1 8,25 6,05 8,51 7,49 8,25 6,05 8,51 7,49 8,25 6,05 8,51 7,49 2,4 7,22 5,29 6,52 5,73 7,22 5,29 6,52 5,73 7,22 5,29 6,52 5,73 2,7 6,39 4,7 5,15 4,53 6,39 4,7 5,15 4,53 6,39 4,7 5,15 4,53 3 5,47 4,23 4,17 3,67 5,47 4,23 4,17 3,67 5,47 4,23 4,17 3,67 3,3 4,72 3,85 3,45 3,03 4,72 3,85 3,45 3,03 4,72 3,85 3,45 3,03 3,6 4,1 3,53 2,9 2,55 4,1 3,53 2,9 2,55 4,1 3,53 2,9 2,55 3,9 3,58 3,16 2,47 2,17 3,58 3,16 2,47 2,17 3,58 3,16 2,47 2,17 4,2 3,09 2,72 2,13 1,87 3,09 2,72 2,13 1,87 3,09 2,72 2,13 1,87 4,5 2,69 2,37 1,85 1,63 2,69 2,37 1,85 1,63 2,69 2,37 1,85 1,63 4,8 2,37 2,08 1,63 1,43 2,37 2,08 1,63 1,43 2,37 2,08 1,63 1,43 5,1 2,1 1,85 1,44 1,27 2,1 1,85 1,44 1,27 2,1 1,85 1,44 1,27 5,4 1,87 1,65 1,29 1,13 1,87 1,65 1,29 1,13 1,87 1,65 1,29 1,13 5,7 1,68 1,48 1,16 1,02 1,68 1,48 1,16 1,02 1,68 1,48 1,16 1,02 6 1,52 1,33 1,04 0,92 1,52 1,33 1,04 0,92 1,52 1,33 1,04 0,92 6,3 1,37 1,21 0,95 0,83 1,37 1,21 0,95 0,83 1,37 1,21 0,95 0,83 6,6 1,25 1,1 0,86 0,76 1,25 1,1 0,86 0,76 1,25 1,1 0,86 0,76 6,9 1,12 1,01 0,79 0,69 1,12 1,01 0,79 0,69 1,12 1,01 0,79 0,69 7,2 1 0,93 0,72 0,64 1 0,93 0,72 0,64 1 0,93 0,72 0,64 7,5 0,89 0,85 0,67 0,59 0,89 0,85 0,67 0,59 0,89 0,85 0,67 0,59 7,8 0,8 0,79 0,62 0,54 0,8 0,79 0,62 0,54 0,8 0,73 0,62 0,54 8,1 0,72 0,73 0,57 0,5 0,72 0,73 0,57 0,5 0,72 0,5 0,57 0,5 35. Maximal values of wind load (thrust and suction) for Arpanel CH PUR/PIR 160 sandwich panels, single-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 15,41 11,3 18,48 19,6 15,41 11,3 18,48 19,6 15,41 11,3 18,48 19,6 1,8 12,84 9, ,61 12,84 9, ,61 12,84 9, ,61 2,1 11,01 8,07 11, ,01 8,07 11, ,01 8,07 11, ,4 9,63 7,06 8,7 7,66 9,63 7,06 8,7 7,66 9,63 7,06 8,7 7,66 2,7 8,56 6,28 6,87 6,05 8,56 6,28 6,87 6,05 8,56 6,28 6,87 6,05 3 7,7 5,65 5,57 4,9 7,7 5,65 5,57 4,9 7,7 5,65 5,57 4,9 3,3 6,69 5,14 4,6 4,05 6,69 5,14 4,6 4,05 6,69 5,14 4,6 4,05 3,6 5,62 4,71 3,87 3,4 5,62 4,71 3,87 3,4 5,62 4,71 3,87 3,4 3,9 4,79 4,21 3,29 2,9 4,79 4,21 3,29 2,9 4,79 4,21 3,29 2,9 4,2 4,13 3,63 2,84 2,5 4,13 3,63 2,84 2,5 4,13 3,63 2,84 2,5 4,5 3,6 3,16 2,47 2,18 3,6 3,16 2,47 2,18 3,6 3,16 2,47 2,18 4,8 3,16 2,78 2,17 1,91 3,16 2,78 2,17 1,91 3,16 2,78 2,17 1,91 5,1 2,8 2,46 1,93 1,7 2,8 2,46 1,93 1,7 2,8 2,46 1,93 1,7 5,4 2,5 2,2 1,72 1,51 2,5 2,2 1,72 1,51 2,5 2,2 1,72 1,51 5,7 2,24 1,97 1,54 1,36 2,24 1,97 1,54 1,36 2,24 1,97 1,54 1,36 6 2,02 1,78 1,39 1,22 2,02 1,78 1,39 1,22 2,02 1,78 1,39 1,22 6,3 1,83 1,61 1,26 1,11 1,83 1,61 1,26 1,11 1,83 1,61 1,26 1,11 6,6 1,67 1,47 1,15 1,01 1,67 1,47 1,15 1,01 1,67 1,47 1,15 1,01 6,9 1,53 1,35 1,05 0,93 1,53 1,35 1,05 0,93 1,53 1,35 1,05 0,93 7,2 1,4 1,24 0,97 0,85 1,4 1,24 0,97 0,85 1,4 1,24 0,97 0,85 7,5 1,29 1,14 0,89 0,78 1,29 1,14 0,89 0,78 1,29 1,14 0,89 0,78 7,8 1,2 1,05 0,82 0,72 1,2 1,05 0,82 0,72 1,2 0,98 0,82 0,72 8,1 1,11 0,98 0,76 0,67 1,11 0,98 0,76 0,67 1,11 0,67 0,76 0,67 96 Resistance tables

97 4. Resistance tables 36. Maximal values of wind load (thrust and suction) for Arpanel CH PUR/PIR 200 sandwich panels, single-span arrangement Gr. I: kolory bardzo jasne Gr. II: kolory jasne Gr. III: kolory ciemne L [m] parcie [kpa] ssanie [kpa] parcie [kpa] ssanie [kpa] parcie [kpa] ssanie [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 19,27 14,13 23,7 21,22 19,27 14,13 23,7 21,22 19,27 14,13 23,7 21,22 1,8 16,06 11,78 16,75 14,74 16,06 11,78 16,75 14,74 16,06 11,78 16,75 14,74 2,1 13,77 10,1 12,3 10,83 13,77 10,1 12,3 10,83 13,77 10,1 12,3 10,83 2,4 12,05 8,83 9,42 8,29 12,05 8,83 9,42 8,29 12,05 8,83 9,42 8,29 2,7 10,6 7,85 7,44 6,55 10,6 7,85 7,44 6,55 10,6 7,85 7,44 6,55 3 8,59 7,07 6,03 5,3 8,59 7,07 6,03 5,3 8,59 7,07 6,03 5,3 3,3 7,1 6,25 4,98 4,38 7,1 6,25 4,98 4,38 7,1 6,25 4,98 4,38 3,6 5,97 5,25 4,19 3,68 5,97 5,25 4,19 3,68 5,97 5,25 4,19 3,68 3,9 5,08 4,47 3,57 3,14 5,08 4,47 3,57 3,14 5,08 4,47 3,57 3,14 4,2 4,38 3,86 3,08 2,71 4,38 3,86 3,08 2,71 4,38 3,86 3,08 2,71 4,5 3,82 3,36 2,68 2,36 3,82 3,36 2,68 2,36 3,82 3,36 2,68 2,36 4,8 3,36 2,95 2,35 2,07 3,36 2,95 2,35 2,07 3,36 2,95 2,35 2,07 5,1 2,97 2,62 2,09 1,84 2,97 2,62 2,09 1,84 2,97 2,62 2,09 1,84 5,4 2,65 2,33 1,86 1,64 2,65 2,33 1,86 1,64 2,65 2,33 1,86 1,64 5,7 2,38 2,09 1,67 1,47 2,38 2,09 1,67 1,47 2,38 2,09 1,67 1,47 6 2,15 1,89 1,51 1,33 2,15 1,89 1,51 1,33 2,15 1,89 1,51 1,33 6,3 1,95 1,71 1,37 1,2 1,95 1,71 1,37 1,2 1,95 1,71 1,37 1,2 6,6 1,77 1,56 1,25 1,1 1,77 1,56 1,25 1,1 1,77 1,56 1,25 1,1 6,9 1,62 1,43 1,14 1 1,62 1,43 1,14 1 1,62 1,43 1,14 1 7,2 1,49 1,31 1,05 0,92 1,49 1,31 1,05 0,92 1,49 1,31 1,05 0,92 7,5 1,37 1,21 0,96 0,85 1,37 1,21 0,96 0,85 1,37 1,21 0,96 0,85 7,8 1,27 1,12 0,89 0,78 1,27 1,12 0,89 0,78 1,27 1,04 0,89 0,78 8,1 1,18 1,04 0,83 0,73 1,18 1,04 0,83 0,73 1,18 0,73 0,83 0, Maximal values of wind load (thrust and suction) for Arpanel CH PUR/PIR 120 sandwich panels, single-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 6,46 9,34 10,87 15,38 6,46 9,34 6,47 15,09 6,46 9,34 6,44 14,66 1,8 5,27 7,61 8,9 10,85 5,27 7,61 5,28 10,57 5,27 7,61 5,25 10,16 2,1 4,42 6,39 7,49 8,09 4,42 6,39 4,44 7,83 4,42 6,39 4,4 7,44 2,4 3,8 5,5 6,45 6,29 3,8 5,5 3,81 6,04 3,8 5,5 3,77 5,68 2,7 3,32 4,39 5,65 5,03 3,32 4,39 3,33 4,81 3,32 4,39 3,29 4,47 3 2,94 2,9 5,01 4,13 2,94 2,9 2,95 3,92 2,94 2,9 2,91 3,17 3,3 2,63 1,99 4,5 3,4 2,63 1,99 2,64 2,91 2,63 1,99 2,61 2,16 3,6 2,38 1,42 4,09 2,57 2,38 1,42 2,39 2,15 2,38 1,42 2,36 1,52 3,9 2,17 1,04 3,74 1,99 2,17 1,04 2,19 1,63 2,17 1,04 2,15 1,1 4,2 2 0,78 3,44 1,58 2 0,78 2,01 1,27 2 0,78 1,98 0,81 4,5 1,85 0,59 3,19 1,28 1,85 0,59 1,86 1,02 1,85 0,59 1,83 0,61 4,8 1,72 0,46 2,97 1,06 1,72 0,46 1,73 0,83 1,72 0,46 1,7 0,47 5,1 1,61 0,37 2,78 0,89 1,61 0,37 1,62 0,68 1,61 0,37 1,59 0,37 5,4 1,51 0,29 2,56 0,76 1,51 0,29 1,52 0,57 1,51 0,29 1,49 0,29 5,7 1,42 0,24 2,34 0,65 1,42 0,24 1,43 0,48 1,42 0,24 1,41 0,23 6 1,35 0,2 2,15 0,57 1,35 0,2 1,36 0,41 1,35 0,2 1,33 0,19 6,3 1,28 0,16 1,98 0,5 1,28 0,16 1,29 0,36 1,28 0,16 1,26 0,15 6,6 1,21 0,14 1,82 0,44 1,21 0,14 1,22 0,31 1,21 0,14 1,2 0,13 6,9 1,16 0,12 1,68 0,39 1,16 0,12 1,17 0,28 1,16 0,12 1,14 0,11 7,2 1,11 0,1 1,55 0,35 1,11 0,1 1,11 0,25 1,11 0,1 1,09 0,09 7,5 1,06 0,09 1,44 0,32 1,06 0,09 1,07 0,22 1,06 0,09 1,04 0,07 7,8 1,02 0,07 1,34 0,29 1,02 0,07 1,02 0,2 1,02 0,07 1 0,06 8,1 0,98 0,07 1,24 0,26 0,98 0,07 0,98 0,18 0,98 0,07 0,96 0,05 97 S/SU MiWo CH D Resistance tables Resistance tables

98 4. Resistance tables 38. Maximal values of wind load (thrust and suction) for Arpanel CH PUR/PIR 160 sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 8,71 11,08 14,66 20,34 8,71 11,08 8,72 20,04 8,71 11,08 8,68 19,59 1,8 7,11 9,04 12,02 14,31 7,11 9,04 7,13 14,02 7,11 9,04 7,08 13,59 2,1 5,97 7,61 10,14 10,65 5,97 7,61 5,99 10,38 5,97 7,61 5,94 9,96 2,4 5,13 6,54 8,73 8,26 5,13 6,54 5,15 8 5,13 6,54 5,09 7,61 2,7 4,47 5,73 7,64 6,61 4,47 5,73 4,49 6,37 4,47 5,73 4, ,96 5,09 6,78 5,42 3,96 5,09 3,98 5,19 3,96 5,09 3,92 4,84 3,3 3,54 3,51 6,09 4,53 3,54 3,51 3,56 4,31 3,54 3,51 3,5 3,87 3,6 3,2 2,49 5,52 3,85 3,2 2,49 3,22 3,56 3,2 2,49 3,16 2,72 3,9 2,91 1,82 5,04 3,16 2,91 1,82 2,93 2,68 2,91 1,82 2,88 1,97 4,2 2,68 1,36 4,64 2,49 2,68 1,36 2,69 2,08 2,68 1,36 2,64 1,46 4,5 2,47 1,04 4,29 2 2,47 1,04 2,49 1,64 2,47 1,04 2,44 1,1 4,8 2,29 0,81 3,99 1,64 2,29 0,81 2,31 1,32 2,29 0,81 2,26 0,85 5,1 2,14 0,64 3,73 1,36 2,14 0,64 2,16 1,08 2,14 0,64 2,11 0,66 5,4 2,01 0,51 3,51 1,15 2,01 0,51 2,02 0,9 2,01 0,51 1,97 0,53 5,7 1,89 0,42 3,3 0,98 1,89 0,42 1,91 0,76 1,89 0,42 1,86 0,42 6 1,78 0,34 3,12 0,84 1,78 0,34 1,8 0,64 1,78 0,34 1,75 0,34 6,3 1,69 0,28 2,91 0,74 1,69 0,28 1,7 0,55 1,69 0,28 1,66 0,28 6,6 1,61 0,24 2,7 0,65 1,61 0,24 1,62 0,48 1,61 0,24 1,58 0,23 6,9 1,53 0,2 2,5 0,57 1,53 0,2 1,54 0,42 1,53 0,2 1,5 0,19 7,2 1,46 0,17 2,33 0,51 1,46 0,17 1,47 0,37 1,46 0,17 1,43 0,16 7,5 1,4 0,15 2,17 0,46 1,4 0,15 1,41 0,33 1,4 0,15 1,37 0,14 7,8 1,34 0,13 2,02 0,41 1,34 0,13 1,35 0,29 1,34 0,13 1,31 0,12 8,1 1,28 0,11 1,89 0,37 1,28 0,11 1,3 0,26 1,28 0,11 1,26 0,1 39. Maximal values of wind load (thrust and suction) for Arpanel CH PUR/PIR 200 sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 10,95 10,49 18,46 21,74 10,95 10,49 10,97 21,43 10,95 10,49 10,91 20,97 1,8 8,96 8,83 15,15 15,23 8,96 8,83 8,98 14,93 8,96 8,83 8,91 14,48 2,1 7,53 7,6 12,79 11,29 7,53 7,6 7, ,53 7,6 7,48 10,57 2,4 6,46 6,65 11,02 8,72 6,46 6,65 6,49 8,45 6,46 6,65 6,41 8,04 2,7 5,63 5,91 9,65 6,95 5,63 5,91 5,66 6,69 5,63 5,91 5,58 6,3 3 4,98 5,31 8,56 5,68 4,98 5,31 5,01 5,43 4,98 5,31 4,92 5,06 3,3 4,45 4,82 7,68 4,73 4,45 4,82 4,48 4,5 4,45 4,82 4,4 4,15 3,6 4,02 3,72 6,96 4,01 4,02 3,72 4,04 3,78 4,02 3,72 3,96 3,45 3,9 3,65 2,7 6,35 3,44 3,65 2,7 3,68 3,23 3,65 2,7 3,6 2,92 4,2 3,35 2,01 5,84 2,98 3,35 2,01 3,38 2,79 3,35 2,01 3,3 2,49 4,5 3,09 1,53 5,4 2,61 3,09 1,53 3,11 2,43 3,09 1,53 3,04 2,01 4,8 2,86 1,18 5,02 2,31 2,86 1,18 2,89 2,14 2,86 1,18 2,81 1,57 5,1 2,67 0,93 4,69 2,06 2,67 0,93 2,69 1,76 2,67 0,93 2,62 1,24 5,4 2,5 0,74 4,4 1,77 2,5 0,74 2,52 1,46 2,5 0,74 2,45 1 5,7 2,35 0,6 4,14 1,51 2,35 0,6 2,37 1,23 2,35 0,6 2,3 0,81 6 2,21 0,49 3,91 1,3 2,21 0,49 2,24 1,05 2,21 0,49 2,17 0,67 6,3 2,09 0,4 3,71 1,13 2,09 0,4 2,12 0,9 2,09 0,4 2,05 0,56 6,6 1,99 0,34 3,52 0,99 1,99 0,34 2,01 0,78 1,99 0,34 1,94 0,47 6,9 1,89 0,28 3,36 0,87 1,89 0,28 1,91 0,68 1,89 0,28 1,85 0,4 7,2 1,8 0,24 3,17 0,77 1,8 0,24 1,82 0,6 1,8 0,24 1,76 0,34 7,5 1,72 0,2 2,96 0,69 1,72 0,2 1,74 0,53 1,72 0,2 1,68 0,29 7,8 1,65 0,17 2,77 0,62 1,65 0,17 1,67 0,47 1,65 0,17 1,61 0,25 8,1 1,58 0,15 2,6 0,56 1,58 0,15 1,6 0,43 1,58 0,15 1,54 0,22 98 Resistance tables

99 4. Resistance tables 40. Maximal values of wind load (thrust and suction) for Arpanel CH PUR/PIR 120 sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 6,3 9,34 10,6 15,77 6,3 9,34 6,31 15,3 6,3 9,34 6,27 14,6 1,8 5,13 7,61 8,67 11,13 5,13 7,61 5,14 10,72 5,13 7,61 5,11 10,11 2,1 4,32 6,39 7,31 8,3 4,32 6,39 4,33 7,94 4,32 6,39 4,29 7,4 2,4 3,71 4,78 6,31 6,43 3,71 4,78 3,73 6,11 3,71 4,78 3,69 5,25 2,7 3,26 3,21 5,55 5,13 3,26 3,21 3,27 4,61 3,26 3,21 3,23 3,49 3 2,9 2,27 4,95 3,96 2,9 2,27 2,91 3,36 2,9 2,27 2,87 2,45 3,3 2,61 1,67 4,46 3,04 2,61 1,67 2,62 2,54 2,61 1,67 2,58 1,8 3,6 2,37 1,28 4,06 2,41 2,37 1,28 2,38 1,99 2,37 1,28 2,35 1,36 3,9 2,17 1 3,73 1,95 2,17 1 2,18 1,6 2,17 1 2,15 1,06 4,2 2 0,81 3,45 1,62 2 0,81 2,01 1,31 2 0,81 1,98 0,85 4,5 1,86 0,66 3,21 1,36 1,86 0,66 1,87 1,09 1,86 0,66 1,84 0,69 4,8 1,74 0,55 3 1,16 1,74 0,55 1,75 0,93 1,74 0,55 1,71 0,57 5,1 1,63 0,47 2,75 1 1,63 0,47 1,64 0,8 1,63 0,47 1,61 0,48 5,4 1,53 0,4 2,49 0,88 1,53 0,4 1,54 0,69 1,53 0,4 1,51 0,41 5,7 1,45 0,35 2,26 0,77 1,45 0,35 1,46 0,61 1,45 0,35 1,43 0,36 6 1,37 0,3 2,06 0,69 1,37 0,3 1,38 0,54 1,37 0,3 1,35 0,31 6,3 1,3 0,27 1,89 0,61 1,3 0,27 1,31 0,48 1,3 0,27 1,28 0,27 6,6 1,24 0,24 1,73 0,55 1,24 0,24 1,25 0,43 1,24 0,24 1,22 0,24 6,9 1,18 0,21 1,58 0,5 1,18 0,21 1,19 0,39 1,18 0,21 1,17 0,22 7,2 1,13 0,19 1,46 0,46 1,13 0,19 1,14 0,35 1,13 0,19 1,12 0,19 7,5 1,09 0,17 1,34 0,42 1,09 0,17 1,09 0,32 1,09 0,17 1,07 0,18 7,8 1,04 0,16 1,24 0,38 1,04 0,16 1,05 0,29 1,04 0,16 1,03 0,16 8,1 1 0,14 1,14 0,35 1 0,14 1,01 0,27 1 0,14 0,99 0, Maximal values of wind load (thrust and suction) for Arpanel CH PUR/PIR 160 sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 8,5 11,08 14,32 20,8 8,5 11,08 8,52 20,3 8,5 11,08 8,47 19,54 1,8 6,93 9,04 11,71 14,67 6,93 9,04 6,95 14,22 6,93 9,04 6,89 13,53 2,1 5,82 7,61 9,87 10,93 5,82 7,61 5,84 10,53 5,82 7,61 5,78 9,91 2,4 5 6,54 8,51 8,48 5 6,54 5,02 8,11 5 6,54 4,96 7,56 2,7 4,37 5,23 7,47 6,77 4,37 5,23 4,39 6,44 4,37 5,23 4,34 5,76 3 3,88 3,65 6,65 5,53 3,88 3,65 3,9 5,2 3,88 3,65 3,84 3,99 3,3 3,49 2,66 5,99 4,55 3,49 2,66 3,5 3,89 3,49 2,66 3,45 2,89 3,6 3,16 2,01 5,45 3,56 3,16 2,01 3,18 3 3,16 2,01 3,12 2,16 3,9 2,89 1,56 5 2,86 2,89 1,56 2,91 2,38 2,89 1,56 2,85 1,67 4,2 2,66 1,24 4,61 2,35 2,66 1,24 2,68 1,94 2,66 1,24 2,63 1,32 4,5 2,47 1,01 4,28 1,96 2,47 1,01 2,48 1,6 2,47 1,01 2,43 1,07 4,8 2,3 0,83 4 1,66 2,3 0,83 2,32 1,35 2,3 0,83 2,26 0,88 5,1 2,15 0,7 3,75 1,43 2,15 0,7 2,17 1,15 2,15 0,7 2,12 0,73 5,4 2,02 0,59 3,53 1,24 2,02 0,59 2,04 0,99 2,02 0,59 1,99 0,62 5,7 1,91 0,51 3,33 1,09 1,91 0,51 1,92 0,87 1,91 0,51 1,87 0,53 6 1,8 0,44 3,08 0,96 1,8 0,44 1,82 0,76 1,8 0,44 1,77 0,46 6,3 1,71 0,39 2,83 0,86 1,71 0,39 1,73 0,68 1,71 0,39 1,68 0,4 6,6 1,63 0,35 2,61 0,77 1,63 0,35 1,64 0,6 1,63 0,35 1,6 0,35 6,9 1,55 0,31 2,41 0,69 1,55 0,31 1,57 0,54 1,55 0,31 1,53 0,31 7,2 1,49 0,28 2,23 0,63 1,49 0,28 1,5 0,49 1,49 0,28 1,46 0,28 7,5 1,42 0,25 2,06 0,57 1,42 0,25 1,44 0,45 1,42 0,25 1,4 0,25 7,8 1,37 0,23 1,91 0,53 1,37 0,23 1,38 0,41 1,37 0,23 1,34 0,23 8,1 1,31 0,21 1,77 0,48 1,31 0,21 1,33 0,37 1,31 0,21 1,29 0,21 99 S/SU MiWo CH D Resistance tables Resistance tables

100 4. Resistance tables 42. Maximal values of wind load (thrust and suction) for Arpanel CH PUR/PIR 200 sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 10,71 10,49 18,05 22,08 10,71 10,49 10,73 21,55 10,71 10,49 10,67 20,75 1,8 8,73 8,83 14,78 15,51 8,73 8,83 8,76 15,02 8,73 8,83 8,69 14,29 2,1 7,33 7,6 12,46 11,51 7,33 7,6 7,36 11,07 7,33 7,6 7,28 10,4 2,4 6,29 6,65 10,74 8,89 6,29 6,65 6,32 8,49 6,29 6,65 6,24 7,89 2,7 5,5 5,91 9,42 7,08 5,5 5,91 5,52 6,72 5,5 5,91 5,44 6,18 3 4,87 5,13 8,38 5,78 4,87 5,13 4,9 5,45 4,87 5,13 4,82 4,96 3,3 4,36 3,7 7,54 4,8 4,36 3,7 4,39 4,51 4,36 3,7 4,31 4,07 3,6 3,95 2,75 6,85 4,06 3,95 2,75 3,98 3,79 3,95 2,75 3,9 3,39 3,9 3,61 2,11 6,27 3,47 3,61 2,11 3,63 3,23 3,61 2,11 3,55 2,78 4,2 3,32 1,66 5,78 3,01 3,32 1,66 3,34 2,79 3,32 1,66 3,26 2,2 4,5 3,07 1,34 5,36 2,63 3,07 1,34 3,09 2,43 3,07 1,34 3,02 1,77 4,8 2,85 1,1 5 2,32 2,85 1,1 2,88 2,05 2,85 1,1 2,8 1,46 5,1 2,67 0,91 4,69 2,06 2,67 0,91 2,69 1,74 2,67 0,91 2,62 1,22 5,4 2,5 0,77 4,41 1,81 2,5 0,77 2,53 1,5 2,5 0,77 2,45 1,03 5,7 2,36 0,66 4,16 1,58 2,36 0,66 2,38 1,3 2,36 0,66 2,31 0,88 6 2,23 0,57 3,94 1,39 2,23 0,57 2,25 1,14 2,23 0,57 2,18 0,77 6,3 2,11 0,49 3,74 1,24 2,11 0,49 2,14 1,01 2,11 0,49 2,07 0,67 6,6 2,01 0,43 3,54 1,11 2,01 0,43 2,03 0,9 2,01 0,43 1,96 0,59 6,9 1,91 0,38 3,28 1 1,91 0,38 1,94 0,81 1,91 0,38 1,87 0,52 7,2 1,83 0,34 3,05 0,9 1,83 0,34 1,85 0,73 1,83 0,34 1,79 0,47 7,5 1,75 0,31 2,84 0,82 1,75 0,31 1,77 0,66 1,75 0,31 1,71 0,42 7,8 1,68 0,28 2,64 0,75 1,68 0,28 1,7 0,6 1,68 0,28 1,64 0,38 8,1 1,61 0,25 2,46 0,69 1,61 0,25 1,63 0,55 1,61 0,25 1,57 0, Maximal values of wind load (thrust and suction) for Arpanel CH PUR sandwich panels, internal temperature (T wew ) = -40 C, double-span arrangement 1 st gr.: very light colors CH PUR 120 CH PUR 160 CH PUR 200 L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 11,54 8,47 13,55 14,68 15,41 11,3 18,48 19,6 19,27 14,13 23,7 21,22 1,8 9,62 7,05 10,91 10,19 12,84 9, ,61 16,06 11,78 16,75 14,74 2,1 8,25 6,05 8,51 7,49 11,01 8,07 11, ,77 10,1 12,3 10,83 2,4 7,22 5,29 6,52 5,73 9,63 7,06 8,7 7,66 12,05 8,83 9,42 8,29 2,7 6,39 4,7 5,15 4,53 8,56 6,28 6,87 6,05 10,6 7,85 7,44 6,55 3 5,47 4,23 4,17 3,67 7,7 5,65 5,57 4,9 8,59 7,07 6,03 5,3 3,3 4,72 3,85 3,45 3,03 6,69 5,14 4,6 4,05 7,1 6,25 4,98 4,38 3,6 4,1 3,53 2,9 2,55 5,62 4,71 3,87 3,4 5,97 5,25 4,19 3,68 3,9 3,58 3,16 2,47 2,17 4,79 4,21 3,29 2,9 5,08 4,47 3,57 3,14 4,2 3,09 2,72 2,13 1,87 4,13 3,63 2,84 2,5 4,38 3,86 3,08 2,71 4,5 2,69 2,37 1,85 1,63 3,6 3,16 2,47 2,18 3,82 3,36 2,68 2,36 4,8 2,37 2,08 1,63 1,43 3,16 2,78 2,17 1,91 3,36 2,95 2,35 2,07 5,1 2,1 1,85 1,44 1,27 2,8 2,46 1,93 1,7 2,97 2,62 2,09 1,84 5,4 1,87 1,65 1,29 1,13 2,5 2,2 1,72 1,51 2,65 2,33 1,86 1,64 5,7 1,68 1,48 1,16 1,02 2,24 1,97 1,54 1,36 2,38 2,09 1,67 1,47 6 1,52 1,33 0,98 0,92 2,02 1,78 1,39 1,22 2,15 1,89 1,51 1,33 6,3 1,37 1,21 0,77 0,83 1,83 1,61 1,26 1,11 1,95 1,71 1,37 1,2 6,6 1,25 1,1 0,59 0,76 1,67 1,47 1,15 1,01 1,77 1,56 1,25 1,1 6,9 1,13 1,01 0,45 0,69 1,53 1,35 1,05 0,93 1,62 1,43 1,14 1 7,2 1,03 0,93 0,32 0,64 1,4 1,24 0,97 0,85 1,49 1,31 1,05 0,92 7,5 0,93 0,85 0,22 0,59 1,29 1,14 0,89 0,78 1,37 1,21 0,96 0,85 7,8 0,85 0,79 0,13 0,54 1,2 1,05 0,82 0,72 1,27 1,12 0,89 0,78 8,1 0,78 0,73 0,06 0,5 1,11 0,98 0,76 0,67 1,18 1,04 0,83 0, Resistance tables

101 4. Resistance tables 44. Maximal values of wind load (thrust and suction) for Arpanel CH PUR sandwich panels, internal temperature (T wew ) = -40 C, double-span arrangement 1 st gr.: very light colors CH PUR 120 CH PUR 160 CH PUR 200 L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 6,55 9,83 10,74 13,64 8,83 11,61 14,47 18,53 11, ,21 19,89 1,8 5,36 8,05 8,75 9,19 7,25 9,53 11,81 12,58 9,14 9,3 14,87 13,44 2,1 4,52 6,79 7,34 6,54 6,12 8,05 9,91 9 7,73 8,03 12,49 9,57 2,4 3,9 5,85 6,3 4,5 5,28 6,94 8,5 6,7 6,67 7,05 10,7 7,08 2,7 3,42 5,14 5,5 2,25 4,63 6,09 7,41 5,13 5,85 6,27 9,33 5,39 3 3,04 4,57 4,86 1,07 4,11 5,42 6,55 2,86 5,2 5,64 8,24 4,2 3, ,7 4,87 5,86 1,54 4,67 5,12 7,35 3,07 3, Maximal values of wind load (thrust and suction) for Arpanel CH PUR sandwich panels, internal temperature (T wew ) = -40 C, double-span arrangement 1 st gr.: very light colors CH PUR 120 CH PUR 160 CH PUR 200 L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 6,38 9,83 10,47 12,97 8,62 11,61 14,13 17,77 10, ,81 18,89 1,8 5,23 8,05 8,53 8,66 7,06 9,53 11,51 11,94 8,92 9,3 14,5 12,58 2,1 4,41 6,79 7,16 4,13 5,96 8,05 9,66 8,48 7,53 8,03 12,16 8,85 2,4 3,81 5,85 6,16 1,95 5,15 6,94 8,29 4,37 6,5 7,05 10,43 6,48 2, ,53 6,09 7,24 2,29 5,71 6,27 9,1 4, ,03 5,42 6,42 1, , Maximal values of wind load (thrust and suction) for Arpanel S MiWo 100 sandwich panels, single-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 6,46 5,08 12,8 11,26 6,46 5,08 12,8 11,26 6,46 5,08 12,8 11,26 1,8 5,38 4,23 8,88 7,81 5,38 4,23 8,88 7,81 5,38 4,23 8,88 7,81 2,1 4,62 3,63 6,52 5,74 4,62 3,63 6,52 5,74 4,62 3,63 6,52 5,74 2,4 4,04 3,17 4,99 4,39 4,04 3,17 4,99 4,39 4,04 3,17 4,99 4,39 2,7 3,59 2,82 3,94 3,47 3,59 2,82 3,94 3,47 3,59 2,82 3,94 3,47 3 3,23 2,54 3,19 2,81 3,23 2,54 3,19 2,81 3,23 2,54 3,19 2,81 3,3 2,87 2,31 2,64 2,32 2,87 2,31 2,64 2,32 2,87 2,31 2,64 2,32 3,6 2,41 2,12 2,22 1,95 2,41 2,12 2,22 1,95 2,41 2,12 2,22 1,95 3,9 2,05 1,81 1,89 1,66 2,05 1,81 1,89 1,66 2,05 1,81 1,89 1,66 4,2 1,77 1,56 1,63 1,43 1,77 1,56 1,63 1,43 1,77 1,56 1,63 1,43 4,5 1,54 1,36 1,42 1,25 1,54 1,36 1,42 1,25 1,54 1,36 1,42 1,25 4,8 1,35 1,19 1,25 1,1 1,35 1,19 1,25 1,1 1,35 1,19 1,25 1,1 5,1 1,2 1,06 1,1 0,97 1,2 1,06 1,1 0,97 1,2 1,06 1,1 0,97 5,4 1,07 0,94 0,99 0,87 1,07 0,94 0,99 0,87 1,07 0,94 0,99 0,87 5,7 0,96 0,85 0,88 0,78 0,96 0,85 0,88 0,78 0,96 0,85 0,88 0,78 6 0,87 0,76 0,8 0,7 0,87 0,76 0,8 0,7 0,87 0,76 0,8 0,7 6,3 0,79 0,69 0,73 0,64 0,79 0,69 0,73 0,64 0,79 0,69 0,73 0,64 6,6 0,72 0,63 0,66 0,58 0,72 0,63 0,66 0,58 0,72 0,63 0,66 0,58 6,9 0,66 0,58 0,6 0,53 0,66 0,58 0,6 0,53 0,66 0,58 0,6 0,53 7,2 0,6 0,53 0,56 0,49 0,6 0,53 0,56 0,49 0,6 0,53 0,56 0,49 7,5 0,56 0,49 0,51 0,45 0,56 0,49 0,51 0,45 0,56 0,49 0,51 0,45 7,8 0,51 0,45 0,47 0,42 0,51 0,45 0,47 0,42 0,51 0,45 0,47 0,42 8,1 0,48 0,42 0,44 0,39 0,48 0,42 0,44 0,39 0,48 0,42 0,44 0,39 S/SU MiWo CH D 101 Resistance tables Resistance tables

102 4. Resistance tables 47. Maximal values of wind load (thrust and suction) for Arpanel S MiWo 120 sandwich panels, single-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 6,51 5,11 15,36 13,51 6,51 5,11 15,36 13,51 6,51 5,11 15,36 13,51 1,8 5,42 4,26 10,66 9,38 5,42 4,26 10,66 9,38 5,42 4,26 10,66 9,38 2,1 4,65 3,65 7,83 6,89 4,65 3,65 7,83 6,89 4,65 3,65 7,83 6,89 2,4 4,07 3,2 5,99 5,27 4,07 3,2 5,99 5,27 4,07 3,2 5,99 5,27 2,7 3,62 2,84 4,73 4,16 3,62 2,84 4,73 4,16 3,62 2,84 4,73 4,16 3 3,25 2,56 3,83 3,37 3,25 2,56 3,83 3,37 3,25 2,56 3,83 3,37 3,3 2,96 2,32 3,17 2,79 2,96 2,32 3,17 2,79 2,96 2,32 3,17 2,79 3,6 2,71 2,13 2,66 2,34 2,71 2,13 2,66 2,34 2,71 2,13 2,66 2,34 3,9 2,47 1,97 2,27 2 2,47 1,97 2,27 2 2,47 1,97 2,27 2 4,2 2,13 1,83 1,96 1,72 2,13 1,83 1,96 1,72 2,13 1,83 1,96 1,72 4,5 1,85 1,63 1,7 1,5 1,85 1,63 1,7 1,5 1,85 1,63 1,7 1,5 4,8 1,63 1,43 1,5 1,32 1,63 1,43 1,5 1,32 1,63 1,43 1,5 1,32 5,1 1,44 1,27 1,33 1,17 1,44 1,27 1,33 1,17 1,44 1,27 1,33 1,17 5,4 1,29 1,13 1,18 1,04 1,29 1,13 1,18 1,04 1,29 1,13 1,18 1,04 5,7 1,16 1,02 1,06 0,93 1,16 1,02 1,06 0,93 1,16 1,02 1,06 0,93 6 1,04 0,92 0,96 0,84 1,04 0,92 0,96 0,84 1,04 0,92 0,96 0,84 6,3 0,95 0,83 0,87 0,77 0,95 0,83 0,87 0,77 0,95 0,83 0,87 0,77 6,6 0,86 0,76 0,79 0,7 0,86 0,76 0,79 0,7 0,86 0,76 0,79 0,7 6,9 0,79 0,69 0,72 0,64 0,79 0,69 0,72 0,64 0,79 0,69 0,72 0,64 7,2 0,73 0,64 0,67 0,59 0,73 0,64 0,67 0,59 0,73 0,64 0,67 0,59 7,5 0,67 0,59 0,61 0,54 0,67 0,59 0,61 0,54 0,67 0,59 0,61 0,54 7,8 0,62 0,54 0,57 0,5 0,62 0,54 0,57 0,5 0,62 0,54 0,57 0,5 8,1 0,57 0,5 0,53 0,46 0,57 0,5 0,53 0,46 0,57 0,5 0,53 0, Maximal values of wind load (thrust and suction) for Arpanel S MiWo 150 sandwich panels, single-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 6,51 5,11 17,27 15,19 6,51 5,11 17,27 15,19 6,51 5,11 17,27 15,19 1,8 5,42 4,26 11,98 10,54 5,42 4,26 11,98 10,54 5,42 4,26 11,98 10,54 2,1 4,65 3,65 8,8 7,74 4,65 3,65 8,8 7,74 4,65 3,65 8,8 7,74 2,4 4,07 3,2 6,73 5,92 4,07 3,2 6,73 5,92 4,07 3,2 6,73 5,92 2,7 3,62 2,84 5,32 4,68 3,62 2,84 5,32 4,68 3,62 2,84 5,32 4,68 3 3,25 2,56 4,31 3,79 3,25 2,56 4,31 3,79 3,25 2,56 4,31 3,79 3,3 2,96 2,32 3,56 3,14 2,96 2,32 3,56 3,14 2,96 2,32 3,56 3,14 3,6 2,71 2,13 3 2,64 2,71 2,13 3 2,64 2,71 2,13 3 2,64 3,9 2,36 1,97 2,55 2,24 2,36 1,97 2,55 2,24 2,36 1,97 2,55 2,24 4,2 2,03 1,79 2,2 1,94 2,03 1,79 2,2 1,94 2,03 1,79 2,2 1,94 4,5 1,77 1,56 1,92 1,69 1,77 1,56 1,92 1,69 1,77 1,56 1,92 1,69 4,8 1,56 1,37 1,68 1,48 1,56 1,37 1,68 1,48 1,56 1,37 1,68 1,48 5,1 1,38 1,21 1,49 1,31 1,38 1,21 1,49 1,31 1,38 1,21 1,49 1,31 5,4 1,23 1,08 1,33 1,17 1,23 1,08 1,33 1,17 1,23 1,08 1,33 1,17 5,7 1,1 0,97 1,19 1,05 1,1 0,97 1,19 1,05 1,1 0,97 1,19 1, ,88 1,08 0,95 1 0,88 1,08 0,95 1 0,88 1,08 0,95 6,3 0,91 0,8 0,98 0,86 0,91 0,8 0,98 0,86 0,91 0,8 0,98 0,86 6,6 0,82 0,72 0,89 0,78 0,82 0,72 0,89 0,78 0,82 0,72 0,89 0,78 6,9 0,75 0,66 0,81 0,72 0,75 0,66 0,81 0,72 0,75 0,66 0,81 0,72 7,2 0,69 0,61 0,75 0,66 0,69 0,61 0,75 0,66 0,69 0,61 0,75 0,66 7,5 0,64 0,56 0,69 0,61 0,64 0,56 0,69 0,61 0,64 0,56 0,69 0,61 7,8 0,59 0,52 0,64 0,56 0,59 0,52 0,64 0,56 0,59 0,52 0,64 0,56 8,1 0,55 0,48 0,59 0,52 0,55 0,48 0,59 0,52 0,55 0,48 0,59 0, Resistance tables

103 4. Resistance tables 49. Maximal values of wind load (thrust and suction) for Arpanel S MiWo 220 sandwich panels, single-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 6,51 5,11 18,69 16,45 6,51 5,11 18,69 16,45 6,51 5,11 18,69 16,45 1,8 5,42 4,26 12,97 11,42 5,42 4,26 12,97 11,42 5,42 4,26 12,97 11,42 2,1 4,65 3,65 9,53 8,38 4,65 3,65 9,53 8,38 4,65 3,65 9,53 8,38 2,4 4,07 3,2 7,29 6,41 4,07 3,2 7,29 6,41 4,07 3,2 7,29 6,41 2,7 3,62 2,84 5,76 5,07 3,62 2,84 5,76 5,07 3,62 2,84 5,76 5,07 3 3,25 2,56 4,67 4,11 3,25 2,56 4,67 4,11 3,25 2,56 4,67 4,11 3,3 2,96 2,32 3,86 3,39 2,96 2,32 3,86 3,39 2,96 2,32 3,86 3,39 3,6 2,71 2,13 3,24 2,85 2,71 2,13 3,24 2,85 2,71 2,13 3,24 2,85 3,9 2,5 1,97 2,76 2,43 2,5 1,97 2,76 2,43 2,5 1,97 2,76 2,43 4,2 2,32 1,83 2,38 2,1 2,32 1,83 2,38 2,1 2,32 1,83 2,38 2,1 4,5 2,17 1,7 2,07 1,82 2,17 1,7 2,07 1,82 2,17 1,7 2,07 1,82 4,8 1,91 1,6 1,82 1,6 1,91 1,6 1,82 1,6 1,91 1,6 1,82 1,6 5,1 1,7 1,49 1,61 1,42 1,7 1,49 1,61 1,42 1,7 1,49 1,61 1,42 5,4 1,51 1,33 1,44 1,27 1,51 1,33 1,44 1,27 1,51 1,33 1,44 1,27 5,7 1,36 1,19 1,29 1,14 1,36 1,19 1,29 1,14 1,36 1,19 1,29 1,14 6 1,23 1,08 1,17 1,03 1,23 1,08 1,17 1,03 1,23 1,08 1,17 1,03 6,3 1,11 0,98 1,06 0,93 1,11 0,98 1,06 0,93 1,11 0,98 1,06 0,93 6,6 1,01 0,89 0,96 0,85 1,01 0,89 0,96 0,85 1,01 0,89 0,96 0,85 6,9 0,93 0,82 0,88 0,78 0,93 0,82 0,88 0,78 0,93 0,82 0,88 0,78 7,2 0,85 0,75 0,81 0,71 0,85 0,75 0,81 0,71 0,85 0,75 0,81 0,71 7,5 0,78 0,69 0,75 0,66 0,78 0,69 0,75 0,66 0,78 0,69 0,75 0,66 7,8 0,72 0,64 0,69 0,61 0,72 0,64 0,69 0,61 0,72 0,64 0,69 0,61 8,1 0,67 0,59 0,64 0,56 0,67 0,59 0,64 0,56 0,67 0,59 0,64 0, Maximal values of wind load (thrust and suction) for Arpanel S MiWo 100 sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 4,89 3,79 6,45 5,46 4,86 3,76 6,45 5,46 4,83 3,71 6,45 5,46 1,8 4,11 3,17 4,6 3,78 4,08 3,14 4,6 3,78 4,05 3,08 4,6 3,78 2,1 3,57 2,74 3,51 2,76 3,54 2,7 3,51 2,76 3,5 2,63 3,51 2,76 2,4 3,15 2,33 2,83 2,09 3,14 2,33 2,83 2,09 3,1 2,31 2,83 2,09 2,7 2,66 1,94 2,39 1,41 2,66 1,94 2,39 1,41 2,57 1,94 2,39 1,41 3 2,27 1,64 2,04 0,53 2,24 1,64 2,04 0,53 2,13 1,05 2,04 0,53 3,3 1,96-1,75-1,93-1,75-1,81-1,75-3,6 1,71-1,53-1,69-1,53-1,56-1,53-3,9 1,51-1,16-1,5-1,16-1,37-1,16-4,2 1,35-0,66-1,35-0,66-1,21-0,66-4, S/SU MiWo CH D 103 Resistance tables Resistance tables

104 4. Resistance tables 51. Maximal values of wind load (thrust and suction) for Arpanel S MiWo 120 sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 4,9 3,81 7,66 6,57 4,88 3,79 7,66 6,57 4,86 3,75 7,66 6,57 1,8 4,11 3,18 5,43 4,56 4,09 3,15 5,43 4,56 4,06 3,1 5,43 4,56 2,1 3,55 2,74 4,09 3,34 3,53 2,7 4,09 3,34 3,49 2,65 4,09 3,34 2,4 3,14 2,41 3,24 2,54 3,12 2,37 3,24 2,54 3,08 2,31 3,24 2,54 2,7 2,83 2,09 2,68 1,98 2,81 2,09 2,68 1,98 2,76 2,05 2,68 1,98 3 2,43 1,77 2,29 1,45 2,43 1,77 2,29 1,45 2,43 1,77 2,29 1,45 3,3 2,11 1,52 2,02 0,75 2,11 1,52 2,02 0,75 2,11 1,34 2,02 0,75 3,6 1,84 1,32 1,74 0,06 1,84 1,32 1,74 0,06 1,81 0,39 1,74 0,06 3,9 1,63-1,53-1,63-1,53-1,58-1,53-4,2 1,45-1,31-1,45-1,31-1,39-1,31-4,5 1,31-0,97-1,31-0,97-1,24-0,97-4,8 1,18-0,48-1,18-0,48-1,12-0,48-5, Maximal values of wind load (thrust and suction) for Arpanel S MiWo 150 sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 4,89 3,81 9,78 8,53 4,87 3,79 9,78 8,53 4,85 3,76 9,78 8,53 1,8 4,08 3,17 6,82 5,92 4,07 3,15 6,82 5,92 4,04 3,11 6,82 5,92 2,1 3,52 2,72 5,05 4,34 3,5 2,69 5,05 4,34 3,47 2,65 5,05 4,34 2,4 3,1 2,39 3,9 3,32 3,08 2,35 3,9 3,32 3,04 2,3 3,9 3,32 2,7 2,78 2,13 3,11 2,61 2,76 2,1 3,11 2,61 2,72 2,04 3,11 2,61 3 2,4 1,9 2,56 2,11 2,35 1,89 2,56 2,11 2,26 1,79 2,56 2,11 3,3 2,04 1,64 2,16 1,75 1,98 1,59 2,16 1,75 1,89 1,44 2,16 1,75 3,6 1,75 1,42 1,85 1,46 1,69 1,32 1,85 1,46 1,59 1,03 1,85 1,46 3,9 1,53 1,22 1,6 1,24 1,46 1,11 1,6 1,24 1,36 0,26 1,6 1,24 4,2 1,36 1,06 1,41 0,97 1,29 0,91 1,41 0,97 1,18-1,41-4,5 1,22 0,93 1,26 0,42 1,14 0,39 1,26 0,42 1,03-1,26-4,8 1,1-1,14-1,03-1,14-0,89-1,14-5,1 1,01-1,03-0,93-1,03-0,54-1,03-5,4 0,93-0,94-0,85-0, ,7 0,86-0,87-0,78-0, ,8-0,81-0,73-0, ,3 0,75-0,76-0,68-0, ,6 0,7-0,71-0,63-0, ,9 0,21-0,66-0,21-0, , Resistance tables

105 4. Resistance tables 53. Maximal values of wind load (thrust and suction) for Arpanel S MiWo 220 sandwich panels, double-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 4,88 3,81 10,53 9,22 4,87 3,8 10,53 9,22 4,85 3,77 10,53 9,22 1,8 4,07 3,17 7,32 6,38 4,05 3,15 7,32 6,38 4,04 3,13 7,32 6,38 2,1 3,49 2,71 5,38 4,67 3,48 2,69 5,38 4,67 3,46 2,66 5,38 4,67 2,4 3,06 2,37 4,13 3,55 3,05 2,35 4,13 3,55 3,02 2,31 4,13 3,55 2,7 2,73 2,11 3,27 2,79 2,71 2,08 3,27 2,79 2,69 2,04 3,27 2,79 3 2,47 1,9 2,65 2,24 2,45 1,87 2,65 2,24 2,42 1,83 2,65 2,24 3,3 2,26 1,73 2,21 1,84 2,24 1,7 2,21 1,84 2,21 1,66 2,21 1,84 3,6 2,02 1,6 1,87 1,53 1,97 1,56 1,87 1,53 1,9 1,51 1,87 1,53 3,9 1,74 1,43 1,6 1,28 1,69 1,36 1,6 1,28 1,61 1,24 1,6 1,28 4,2 1,52 1,24 1,38 1,08 1,46 1,16 1,38 1,08 1,39 1,02 1,38 1,08 4,5 1,34 1,08 1,21 0,92 1,29 0,99 1,21 0,92 1,2 0,48 1,21 0,92 4,8 1,2 0,94 1,07 0,76 1,14 0,85 1,07 0,76 1,05-1,07-5,1 1,08 0,83 0,96 0,39 1,02 0,56 0,96 0,39 0,92-0,96-5,4 0,98 0,74 0,86 0,01 0,92 0,18 0,86 0,01 0,82-0,86-5,7 0,89-0,78-0,83-0,78-0,61-0,78-6 0,83-0,72-0,77-0,72-0,41-0,72-6,3 0,77-0,66-0,71-0,66-0,05-0,66-6,6 0,72-0,61-0,65-0, ,9 0,67-0,54-0,6-0, ,2 0,63-0,43-0,54-0, ,5 0,59-0,07-0,44-0, , Maximal values of wind load (thrust and suction) for Arpanel S MiWo 100 sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 4,49 3,41 4,53 3,56 4,44 3,33 4,53 3,56 4,36 3,21 4,53 3,56 1,8 3,74 2,91 3,27 2,43 3,6 2,82 3,27 2,43 3,39 2,52 3,27 2,43 2,1 2,97 2,31 2,53 0,89 2,81 2,07 2,53 0,89 2,57 1,4 2,53 0,89 2,4 2,48-2,07-2,31-2,07-2,04-2,07-2,7 2,17-1,76-1,98-1,76-1,6-1,76-3 1,96-1,16-1,75-1,16-1,08-1,16-3,3 1,77-0,38-1,6-0,38-0,71-0,38-3, Maximal values of wind load (thrust and suction) for Arpanel S MiWo 120 sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 4,45 3,4 5,32 4,31 4,4 3,33 5,32 4,31 4,33 3,23 5,32 4,31 1,8 3,79 2,87 3,81 2,96 3,74 2,79 3,81 2,96 3,66 2,67 3,81 2,96 2,1 3,35 2,5 2,91 2,02 3,21 2,43 2,91 2,02 3,01 2,2 2,91 2,02 2,4 2,74 2,08 2,33 0,72 2,59 1,91 2,33 0,72 2,37 1,23 2,33 0,72 2,7 2,35-1,95-2,18-1,95-1,93-1,95-3 2,08-1,68-1,9-1,68-1,59-1,68-3,3 1,84-1,22-1,71-1,22-1,16-1,22-3,6 1,65-0,67-1,56-0,67-0,8-0,67-3, Resistance tables MiWo CH D S/SU Resistance tables

106 4. Resistance tables 56. Maximal values of wind load (thrust and suction) for Arpanel S MiWo 150 sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 4,39 3,37 5,88 4,98 4,35 3,31 5,88 4,98 4,3 3,23 5,88 4,98 1,8 3,71 2,82 4,15 3,42 3,67 2,76 4,15 3,42 3,6 2,66 4,15 3,42 2,1 2,95 2,4 3,11 2,47 2,84 2,23 3,11 2,47 2,68 1,99 3,11 2,47 2,4 2,34 1,83 2,44 1,85 2,22 1,65 2,44 1,85 2,04 1,18 2,44 1,85 2,7 1,94 1,45 1,99 1,41 1,8 1,17 1,99 1,41 1,6 0,32 1,99 1,41 3 1,65 1,18 1,67 0,84 1,5 0,59 1,67 0,84 1,22-1,67-3,3 1,46 0,84 1,46 0,4 1,3 0,17 1,46 0,4 0,78-1,46-3,6 1,31-1,28-1,13-1,28-0,41-1,28-3,9 1,19-1,1-0,87-1,1-0,1-1,1-4,2 1,1-0,89-0,66-0, ,5 1,03-0,71-0,49-0, ,8 0,93-0,57-0,35-0, ,1 0,83-0,45-0,23-0, ,4 0,65-0,34-0,13-0, ,7 0,17-0,26-0,05-0, ,07-0,22-0,02-0, , Maximal values of wind load (thrust and suction) for Arpanel S MiWo 220 sandwich panels, three-span arrangement 1 st gr.: very light colors 2 nd gr.: light colors 3 rd gr.: dark colors L [m] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] thrust [kpa] suction [kpa] SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN SGU SGN 1,5 4,34 3,36 6,24 5,36 4,32 3,32 6,24 5,36 4,28 3,26 6,24 5,36 1,8 3,63 2,79 4,34 3,66 3,6 2,74 4,34 3,66 3,56 2,67 4,34 3,66 2,1 3,14 2,39 3,19 2,62 3,1 2,34 3,19 2,62 3,05 2,26 3,19 2,62 2,4 2,67 2,1 2,44 1,94 2,58 2,04 2,44 1,94 2,46 1,88 2,44 1,94 2,7 2,14 1,71 1,93 1,47 2,05 1,57 1,93 1,47 1,91 1,36 1,93 1,47 3 1,77 1,37 1,57 1,12 1,67 1,21 1,57 1,12 1,51 0,68 1,57 1,12 3,3 1,52 1,13 1,32 0,72 1,41 0,85 1,32 0,72 1,24 0,14 1,32 0,72 3,6 1,31 0,93 1,11 0,31 1,19 0,43 1,11 0,31 0,94-1,11-3,9 1,15-0,95-1,02-0,95-0,58-0,95-4,2 1,03-0,75-0,87-0,75-0,29-0,75-4,5 0,93-0,54-0,65-0,54-0,04-0,54-4,8 0,85-0,37-0,47-0, ,1 0,77-0,22-0,32-0, ,4 0,66-0,09-0,19-0, , Resistance tables

107 5. Transport instructions 107 Transport instructions

108 5. Transport instructions Sandwich panels packing Transport and delivery The ARPANEL sandwich panels are packed in a horizontal position, placed one on the other, and properly secured. The packaging manner depends on the type and length of the panels. Each package has special protections installed on both sides, securing the panels against damages, and the whole package is wrapped with polyethylene foil, so it does not get dirty during the transport. Standard height of the package should not exceed 1.20m + a cushion about 20 cm, width of 1.17 m, length of 18.5 m, and weights of 4000 kg. The time from the moment of production to receipt of the ARPANEL sandwich panels, in case of PUR/PIR filling, is at least 48 h, while in case of the mineral wool core panels it amounts to 24 h. A basic mean of transport of the ARPANEL sandwich panels are fully operational trucks, without a tilt or with a side curtain, which enables side unloading (from both sides), or top unloading, with proper width of the loading surface, at least 2.5m, and height at least 2.6m. Trucks with a tilt need to be characterized with certain payload weight. There also needs to be a possibility to fasten the packages through transport belts. The trailers need to be clean, they cannot possess any protruding sharp elements. Any potential protruding elements need to be properly secured. Length of the vehicle needs to be adjusted to the length of panels, so the packages lay within the whole length of the trailer. It is allowed to stack up the panels in two layers. The panels may also protrude from the trailer, but only up to 1.5 m. 108 Transport instructions

109 5. Transport instructions The truck driver should fasten the load with transport belts to the trailer, so while the vehicle moves the panels stay at their places (with spaces up to 2m between them). During the transport, the truck driver is obliged to control the load, especially the belts, so they do not deform the panels. The number of packages in one transport depends on the thickness and length of panels, therefore the whole package. Each package loaded on the trailer is separated from the other with Styrofoam or foam separation sheets, creating proper spaces. They enable to lift the packages with a forklift or a sling with textile belts. Responsibility for the manner of transport and protection of the panels placed in the truck is borne by the carrier. Unloading The recipient is obliged to organize the equipment, machines as well as the labor force necessary for the unloading. Before unloading the packages with the ARPANEL sandwich panels, there is a need to verify the technical condition of the package carefully. Special attention should be paid not to damage the panels during unloading. The packages with panels should not be underpropped or spot lifted, as this may damage the cladding of the sandwich panel, which is located in the lowest package. To avoid such situations the load should be distributed on a bigger surface. What is more, one panel should not be pushed against the other one, as they may get scratched. It is forbidden to walk on the packages with sandwich panels, during the process of unloading or storing, because there is a danger of damaging or deforming the cladding. The process of unloading may take place through a forklift with a wide spacing and protected forks, or through a construction crane, lift or bridge crane. It is possible to use a lifting beam and a sling with textile belts for that purpose. Packages that are more than 6 m long and unloaded through a construction crane should be lifted through a sling with textile belts. Special pads are placed between the sling and upper and lower part of the package, which enable spacing of the belts wider than the package. It is forbidden to use steel ropes and chains to lift the panels or packages against the Styrofoam pads. (Fig. 1). Packages that are more than 6 m long should be unloaded through a special lifting beam from top pf the package, the spacing sheet in the bottom part of the package and textile belts. (Fig. 2). fig. 1 fig Transport instructions

110 5. Transport instructions Storage Packages with the ARPANEL sandwich panels should be stored on a construction side, with preserverance of a slight slope of about 2% along the side edge, and on factory-made pads. To avoid dents and impressions on the claddings, it is not permitted to stack up the packages with panels. It is recommended to store the ARPANEL sandwich panels in a regular temperature, in closed and wellventilated rooms. Storage time should not exceed 4 weeks. Storing the packages on the open air is permitted only for a short time, under a condition that they are properly secured against rain, strong wind, snow and impurities. For that purpose, it is recommended to apply a tilt permeable to air, enabling removal of humidity. (Fig. 3). Slope 2% fig Transport instructions

111 6. Basic information on installation of ARPANEL sandwich panels 111 Basic information on installation of ARPANEL sandwich panels

112 6. Basic information on installation of the ARPANEL sandwich panels The ARPANEL sandwich panels - covering materials - are a modern construction solution. They should be assembled and fixed with adequate assembly techniques. In order not to make any mistakes, which could lead to non-aesthetic and improper installation of the ARPANEL sandwich panels, it is necessary to get familiar with several principles and instruction developed during real installation procedures. The applied equipment, stored panels, installation materials, sealing materials require simple but specific parameters. Propositions for solutions result form an analysis of the present problems, which are caused by violence of basic and advanced principles of installation of light constructions prepared from sandwich panels. You need to follow recommendations for each installation stage systematically, especially to verify precision of joints, quality of locks adjustments and additionally, according to instructions, to apply sealing systems listed in the design. Special attention should be paid to strict adjustment of neighboring panels. Any installation deviations of the structure should not exceed the permissible values. Seals along the lengthwise joints need to be installed according the recommendations of ARPANEL (they are placed on the edge of a panel before installing the other one). Structure tightness is secured through application of proper joints with sealing washers and masses sealing the joints and structures in sports exposed to water penetration. Overlaps on joints of internal and external structures should present dimensions required by the manufacturer. You need to protect your eyes while cutting and drilling. The installation process needs to be planned before commencement of works. You need to specify all necessary details, positions and locations of the panels according to the panels list of cuttings. When the ARPANEL sandwich panels are delivered to the construction site, the panel packets should be sorted properly, so the order of installation steps is facilitated, with consideration of their direction, e.g. taking wind and rain into account. In case of facade panels, care for this detail is also connected with visual and aesthetic aspect (you need to observe and avoid mixing the packets, which is reflected in the facade aesthetics). Transporting and moving the ARPANEL sandwich panels during the installation process is possible with consideration of the wind directions, which allows to control their behavior, enabling to adjust them in certain installation areas. Before the end of a work shift, all installed ARPANEL sandwich panels need to be fastened permanently to the bearing structure and elements of the light roofing. Panels that are not installed should be arranged and fastened together in a packet. Installation of the ARPANEL sandwich panels starts with placing the auxiliary scaffolding along the spans, following manufacturer s recommendations and proper legal provisions. All necessary technological operations are carried out from this scaffolding. Regarding the placement direction, you should observe recommendations provided in the detailed design, regarding the manner of sandwich panels installation (perseverance of order, direction of placement and location of locks). 112 Basic information on installation of ARPANEL sandwich panels

113 6. Basic information on installation of the ARPANEL sandwich panels ARPANEL wall panels ARPANEL wall panels with PUR/PIR and MiWo core are most often installed vertically or horizontally. Other solutions - e.g. diagonal - are also encountered, but they pose a serious difficulty in installation and exploitation terms. A corresponding bearing structure is selected for the chosen installation variant, providing secure shifting of deadweight of the panels, later installed roofing and loads impacting the panels (caused by thrust and suction of the wind, together with fluctuations of the temperature). Offers of numerous manufacturers (including ARPANEL), present a tendency to standardize the systems, which allows to choose panels that can be placed on a facade, with differentiation of The fastening manner (visible and hidden joints), and systems of complementary elements (accessories that mask joints of neighboring panels, sealings, fastening systems, auxiliary equipment, etc.). Before installation, each panel is verified in terms of its adjustment to the installation place (correctness of choice of length and width, and the condition of the longitudinal joint in terms of sealing). Vertical installation of the ARPANEL sandwich panels in accordance to the manufacturer s instruction, is carried out in the direction suggested in the design (wind and aesthetics). Having drilled the holes for joints in all overlapping parts of the panels, and in the spots of their fastening to the bearing structure, the protective foil is removed. Installation of wall sandwich panels in a horizontal arrangement Installation of the ARPANEL S sandwich panels Installation of wall sandwich panels in a vertical arrangement Installation of the ARPANEL SU sandwich panels 113 Basic information on installation of ARPANEL sandwich panels

114 6. Basic information on installation of the ARPANEL sandwich panels When one panel have been installed, another one is moved to the lock of that first panel, and pushed towards it (manually or mechanically), until a tight joint on the edges of both panels is achieved. Continuous geodesic control over verticality of the installed panels is recommended. With vertical arrangement of the ARPANEL sandwich panels, before their installation, it is recommended to geodesically lay out modular axis (or edges) on beams of the steel structure, which is advisable when leaving open window, door or gate zones. Horizontal installation of the ARPANEL sandwich panels begins on a ground beam flashing, and lead in certain strips towards the roof. The panels are lifted through the clamps installed at their ends, sackcloth belts, channel bar holders installed at panels ends and equipped with hooks for slings, and through other permitted installation techniques, including suction cups. The panels are arranged subsequently in the installation position (when the controlling lines marking on the bearing structure are helpful). Afterwards, they are fastened to the structure with joints described in the detailed designed by the designer, according to recommendations. Attention is focused on accuracy of the joints, and such spots are secured against penetration of potential gaps by rainwater and humidity, and from corrosion with a special renovation stick in case of very light damages to the surface. A significant element of works is proper installation of gutter, eliminating the risk of curtaining on the facade, and water outflow from the roof. nstallation of the sling (example) L 6 m L > 6 m ½ L ½ L ¼ L ½ L ¼ L Application of a channel bar cover when lifting wall panels L< 6 m wide Application of a channel bar cover when lifting wall panels L > 6 m wide 114 Basic information on installation of ARPANEL sandwich panels

115 6. Basic information on installation of the ARPANEL sandwich panels ARPANEL D PUR/PIR roof panels Construction cranes, elevators and specialist machines with extension arms are used in transporting and moving the panels. Principles of security need to be observed within the working zone of the crane. You need to carry out all the installation works in accordance with general OSH regulations for installation works and roofwork, and apply special equipment and devices protecting against falling from height during the installation process. The unauthorized persons are forbidden to be present within the prohibited zones. It is forbidden to carry out the installation works during excessive wind and strong rain. ARPANEL D PUR/PIR roof sandwich panels are moved manually or through a lifting device to the installation sport, described in the detailed design. Before installing the panels, you need to install the recommended sealing tapes and bottom elements of flashings properly, on surfaces adjacent to panels of the ground structure (in places touching the placed panel). Workers can walk on the panels only after fastening them to the bearing structure, and if the roof slope is insignificant and weather conditions are safe (it is forbidden to walk on wet and ice-covered surfaces, with strong blows of wind). When installing the ARPANEL sandwich panels, you need to specify and prepare communication routes for workers, so coating of the sandwich panels is not trampled or damages. While walking on the installed panels, the shoe soles should be free from sharp, protruding fragments of sheets, stones, caps, screws etc. The best manner to preserve clean environment is to maintain neatness on the roof surfaces (continuous removal of any installation waste with soft broomsticks, and placing it in bags). joint Manner of installation of the ARPANEL sandwich panels, perseverance of the installation order, direction of installation and location of locks is a result of recommendations of the detailed design. When bearing capacity of the roof is high enough, a packet with sandwich panels secured with belts may be placed on it. They are moved by a construction crane characterized by required lifting capacity and sufficient outreach. Afterwards, the steel purling Installation of roof panels roof panel 115 Basic information on installation of ARPANEL sandwich panels

116 6. Basic information on installation of the ARPANEL sandwich panels Manner of fastening the neighboring roof panels (example) Taking panels from the packet Regarding qualities of the ARPANEL D PUR/PIR sandwich roof panels, a minimal angle of depression needs to be maintained during the installation process, so no water remains on the surface, and there is no risk of rainwater penetrating any potential gaps. The water present on the surface can discolor the cladding and trigger corrosion, especially in the joints. Water that reached the insulation layer deteriorates its thermal parameters and may degenerate the roofing (e.g. in low temperatures, water penetrating the lock causes it to freeze, which results in delamination and unsealing of the joint). When a designer does not describe the slope angle of the roof, the most frequent critical values of minimal slopes are 5% in case of plain roof panels (with no skylights), and 7% for roof panels joined lengthwise or with skylights. All flashings need to be prepared according to the design and installation instructions provided by the panels manufacturer, with application of systemic elements. Special attention needs to be paid to accuracy of the joints. All of them require to be secured against penetration of potential gaps by rainwater and humidity, and to be protected against thermal conditions and corrosion. The Contractor and supervisory workers need to oversee and monitor performance of all works connected with installation of a roof drainage system (gutters with proper circumference, adjusted with form, section and installation spot to the slope and surface of the roof, internal ducts, etc.) In this places, special precision should be applied in installation works connected with correctness of sealing against penetration by rainwater, and through eliminating a possibility of water remaining on the surface. Standard arrangement of the panels joints and their fastening Fastening of the ARPANEL PUR/PIR panel to the roof structure 300 self-drilling joint mounting ARPANEL roof panel support it is recommended to use PES tape before installation 116 Basic information on installation of ARPANEL sandwich panels

117 6. Basic information on installation of the ARPANEL sandwich panels Types of cuts of the ARPANEL sandwich panels The roof ARPANEL D PUR/PIR sandwich panels may be manufactured with left or right undercuts, regarding the design needs. If length of the roofing pitch exceeds the maximum product length, the panels may be joined together. The upper panel (covering one) is provided with an undercut in the overlay. Its size is from mm, depending on the needs. The undercut may be also carried out in the lower panel, to embed a gutter strip. In such a case, a standard undercut is 50 mm. On the basis of the so-called free trapezoid location (empty hump), the panels are called left or right, what renders it easier to mark the installation manner. While selecting the undercuts, you need to clearly specify the direction of installation of the panels, what is defined by the determination - left panel and right panel. Joining the panels lengthwise The installation direction considers the directions of potential rains and winds. Joining the panels with length of L > 18 m max 10 Regarding the undercut location, the ARPANEL roof panels are characterized with the following installation directions: Roof panels installed from left to right (empty hump on the left - left undercut; Roof panels installed from right to left (empty hump on the right - right undercut; Ridge rail 5 min 40 min 40 6 Drip cap 7 1. Self-drilling joint 2. Butyl sealing tape 3. Panel fastening joint 4. Roof panel 5. Self-adhesive sealing tape 6. Impregnated polyurethane sealing or installation foam 7. Steel purling, cold-bent, hot rolled, wooden, etc. according to the structural design Ridge rail installation of the panel from the right Right cut mm Drip cap installation of the panel from the left Left cut mm 117 Basic information on installation of ARPANEL sandwich panels

118 6. Basic information on installation of the ARPANEL sandwich panels Determination of the undercut side poses a highly significant element while preparing the list of cuts, as the selected type of the undercut determined the installation direction. When sandwich panels are manufactured with a specified side of undercut, it is practically impossible to change the installation direction, and causes extreme difficulties while installing the panels. Fastening materials ARPANEL sandwich panels Installation of the ARPANEL sandwich panels on the bearing structures takes place through fastening with original, systemic joints and fastening elements, permitted by the panels manufacturer. This pertains to screws and self-drilling or self-tapping screws with washers, through-bolts, calottes, connectors, seals, flashings, etc.). Regarding the type and thickness of the ARPANEL sandwich panel applied in the structure, the applied screws/bolts should correspond with their diameters and lengths, together with other accessories. All of them should be provided with sealing-vulcanizing washers, as a contact of adjacent surfaces to the joined panels. When the object is exposed to an increased level of humidity, and there is some influence of chemical factors, you should apply the recommended stainless steel connectors of identified tensile strength according to proper standards. To improve aesthetic aspects of the installation, especially at joints of the ARPANEL sandwich panels with a visible fastening, there is a need to apply connectors with powder coated heads, in color matching the hue of facade sheets of the sandwich panels, or equipped with plastic caps in the same color as the panel. Manufacturers apply checked solution of the sandwich panels fastening to grounds of various sorts (e.g. to wooden, steel, concrete or cell structures). optimize the drilling performance (self-drilling joints are equipped with an individual blade-drill for every fastening). Therefore, you are able to maintain equal and stable tearing forces, which minimize the risk of deformations of cladding sheets (a system of regulating the depth of required embedding has been applied), and improve resistance of joints against influence of external factors (e.g. waterproof joint). This in turn provides security of the structure, and eliminates any installation clearances (not tightened screws and shifts, which may appear between the sandwich panels and the bearing, which the sandwich panel is fastened to). It is recommended to apply calottes (clamp-shaped socket elements with sealing from the inside, adjusted in sizes to the front and side surfaces of the trapezoid of a sandwich panel) installations of the ARPANEL roof sandwich panels (trapezoidal profiling). These calottes distribute tension force of the screws equally on bigger surfaces, and maintain watertightness of the prepared joints. In majority of cases, they are more effective than traditional washers made from EPDM type sealing masses. Responsibility for the quality of the performed installation works is borne by the contractor and his controllership. Most frequently, the main reason of leaking coatings is the performed installation. To provide the optimal effect, it is recommended to follow instructions of the technical advisor of the manufacturer. Furthermore, it is also advisable to employ specialized teams, familiar with specificity of light structures installation, to install the ARPANEL sandwich panels. To achieve a proper fastening of the ARPANEL sandwich panels to the structure, it is necessary to maintain a perpendicular position of the screw to the faying face during embedding. Therefore, within the installation process, you should apply specialist drill-drivers equipped with guide heads, which enable application of long joints and limit the embedding depth. These elements allow to perform drilling and fastening in a single operation, and with application of a single power tool, which exerts certain influence on quality and time savings, 118 Basic information on installation of ARPANEL sandwich panels

119 6. Basic information on installation of the ARPANEL sandwich panels Adherence of a connection screw to the panel Re-cutting of the ARPANEL sandwich panels and flashings Re-cutting of panels and flashing on a construction site It is recommended to use only sawing machines with fine blades or special circular saws for metal while re-cutting the ARPANEL sandwich panels. These tools may be applied only with accurate guiding systems. Any filings resulting from cutting need to be removed immediately! too weakly (not tightened) It is forbidden to apply angle grinders and other devices, which may generate extensive heat in the cutting zone, for flashings and ARPANEL sandwich panels cutting. It may result with damages to anti-corrosion coatings of steel claddings! Any cutouts in wall and roof elements, prepared before installation of the panels, need to be stiffened properly, as there is a risk of weakening the cross-section! In case of cutting the flashings, you may use only the snips. correct Cutting of panels and flashings need to be performed only on especially adjusted stands (properly secured with e.g. felt). This allows to avoid damages to the panels! Before commencing the works you need to remove any protective foil that secures surface of the panels! It is absolutely forbidden to perform cutting on roofs, scaffolding or working platforms! too strong (overtighened) 119 Basic information on installation of ARPANEL sandwich panels

120 NOTE: We hereby inform that R&D works over our product are being performed on continuous basis. The owner and manufacturer of the ARPANEL sandwich panels reserved a right to change the proposed solutions and modify the product. The propositions presented above do not constitute an offer for a single variant for the expected technical solutions. The designers and subjects that realize the documentation and construction objects, can always consult their propositions for design solutions with our technical advisors. Solutions presented in this technical catalog are of exemplary character, and they need to be consulted with a designer of a given object. ARPANEL bears no responsibility for mistakes resulting from improper application of information included in the technical catalog. 120 Basic information on installation of ARPANEL sandwich panels

121 7. Product guarantee for the ARPANEL sandwich panels with standard cladding 121 Product guarantee for the ARPANEL sandwich panels with standard cladding

122 7. Product guarantee for the ARPANEL sandwich panels with standard cladding The scope of provided guarantees: Subject of the quality guarantee issued by ARPANEL for 3 years is posed by durability of internal and external protective coatings of steel claddings that cover the ARPANEL sandwich panels. Location of the use of the panels is assumed as environment with corrosion category up to C3. Responsibility of the manufacturer within this scope includes only the defects that result from the sold product. The guarantee does not cover: corrosion of damages to the coating and panels, together with their edges, caused by external or mechanical factors, such as deformations, delamination, bends, scratches, abrasion, smudges with paint and grease; results of maintenance actions performed with scratching and denting tools and chemical compounds damaging the organic layer of the cladding, such as acid and alkaline solutions and preparations with chloride ions or hypochlorites, and exploitation thermal loads (temperature exceeding 60 C), present in internal claddings; corrosion caused by incorrect cutting, cutting-out, drilling etc.; use of improper tools and devices, therefore the filings, cuttings and dusts; defects resulting from improper choice and application of products, violating the reference documentation, responsibility for which is borne by persons holding independent technical functions in the construction industry, such as designers, site managers and installation managers; repairs performed by the Purchaser on his own, such as: disassembling, improper re-cutting and making holes. The risk for these works is borne solely by the Purchaser; aging of the coatings in a form of change in color and gloss, which pose a natural process taking place as a result of UV radiation; differences in surfaces and hues of coated sheets, corresponding to the permitted tolerances for hues; damages resulting from force majeure. Conditions for the product guarantee during transport, unloading, storage, assembling and using (including maintenance) the ARPANEL sandwich panels, you need to observe the principles of construction practice and guidelines published in technical catalogs, product charts and official publications on the website installation of the panels on the bearing structure may be carried out only with application of the joints that meet requirements of the designer and mandatory regulations; defects that results from accumulation of sediments, own and foreign corrosion, slag residues, color deposits on the surface - in the environment with chloride ions in increased temperatures, resulting from electric discharges in traction of trams, trains etc., remaining in neighborhood of sandwich panels, both stored and installed; during installation, including cutting, only the manufacturer recommended tools, corresponding to real working conditions, were applied; the protective foil needs to be removed not later than a month after the purchase date, and not later after three months after production by ARPANEL; corrosion of coatings of panels installed in the neighborhood of salty sea water and salty spray, if it was not reported beforehand; dirty surfaces of the sandwich panels need to be cleaned with non-scratching tools, with cleaning solutions of phosphoric acid (e.g. to remove cement stains, mortars, sediments that are hard to wash off), cleaning preparations with phosphates and solutions of 122 Product guarantee for the ARPANEL sandwich panels with standard cladding

123 7. Product guarantee for the ARPANEL sandwich panels with standard cladding detergents, methyl, ethyl, isopropylene alcohol solutions, acetone (e.g. to remove oil and grease stains) permitted by the National Institute of Hygiene, in concentrations recommended by their manufacturers, and the cleaned surface needs to be carefully rinsed with water, but not under pressure. UV radiation cannot be used to disinfect the rooms, with elements covered with PVC(F) coating; Guarantee limitations responsibility of ARPANEL is limited to goods and products applied in Poland and EU, up to the value of the delivered product, and it does not cover damages related to defects other than those related to the defected material, i.e. sandwich panels; the panels were not disassembled, and were fastened to the bearing structure only one time; the guarantee excludes responsibility of ARPANEL for the manufacturer s warranty; the rooms, where the panels are used, need to be well-ventilated, providing proper relative humidity of air, up to 65% (a short-lasting increase of air humidity to 75% is permitted). In case of panels with PVC(F) cladding, the maximal relative humidity is 75% (a short-lasting increase to 85% is permitted); in case of the ARPANEL PUR/PIR roof sandwich panels, the minimal roof slope is 5% for plain panels, with no skylights, and 7% for panel joined lengthwise or with skylights, and the roof should be prepared with the manner providing easy drainage of water along the whole ridge-drip cap line. More than 3 years guarantee without a written consent of ARPANEL, it is impossible to transfer rights of the Purchaser resulting from this guarantee on other persons (assignment right); the guarantee shall be governed and interpreted according to Polish law, and in all matters not settled therein, provisions of the Civil Code shall apply; the Guarantee shall be valid only when the Purchaser makes the whole payment for the delivered goods, without any deductions; the Purchaser shall not be entitled to any rights arising from the warranty, even when the remaining provisions are not effective. in case of a guarantee period exceeding 3 years, the Purchaser - at his own expense - is obliged to control the condition of the panels before the period of 3 years from commencement of the guarantee period lapses, with participation of the ARPANEL representative, which should be confirmed through a written protocol with description of the performed control, signed by both parties, one counterpart for each party. ARPANEL needs to be informed about the date of the control at least 30 beforehand, so its representative may participate. At the basis of its results, ARPANEL may recommend maintenance works, which the Purchaser is obliged to perform at his own expense, within 30 days from communicating the recommendations. Failure to perform the maintenance works recommended by ARPANEL causes the guarantee to become null and void. The guarantee period may be extended to 5 years. 123 Product guarantee for the ARPANEL sandwich panels with standard cladding

124 7. Product guarantee for the ARPANEL sandwich panels with standard cladding Complaint procedure A condition for commencing the complaint process, on the pain of losing rights arising from this guarantee, is constituted by: immediately, not later than 5 days after revealing the defect, submitting the letter of complaint to the ARPANEL office - the address corresponding to the material purchase - as a letter with delivery confirmation. delivery of a copy of a purchase receipt, a confirmation of the final payment for the object and the document of the issued guarantee, provision of free and direct access to the object of complaint to identify the products and correctness of their usage and maintenance; any permits, passes, permissions to move within the construction site remain attributable to the Ordering Party; ARPANEL and the Purchaser decide on reasons of the defects. In case of any doubts, the Parties shall designate a surveyor, who will determine the reasons of such defects. If the Parties fail to reach an agreement related to the choice of a surveyor, this choice shall be made by ARPANEL; Costs of the surveyor s work shall be borne by both Parties, divided into equal halves; any disputes arising from this guarantee shall be settled amicably, according to the positive effect principle. As a last resort, any disputes shall be settled by a court of law, with jurisdiction over ARPANEL - manufacturer of the sandwich panels; if the complaint is recognized as justified, ARPANEL shall be obliged to remove the defect at its own experience (e.g. to repair it if possible), or to deliver a product free from any defects, as soon as possible, but not later than after 21 days from the date of recognizing the complaint as justified. 124 Product guarantee for the ARPANEL sandwich panels with standard cladding

125 8. Declarations 125 Declarations

126 8. Declarations Declarations of performance characteristics of ARPANEL have been issued on the basis of type tests for ARPANEL sandwich panels with PUR/PIR core and ARPANEL sandwich panels with MiWo, performed in the Institute of Construction Technology, according to the requirements of the European standard PN-EN 14509, and on the basis of quality control. They are also available on the website. 126 Declarations

127 9. Hygienic certificates 127 Hygienic certificates

128 9. Hygienic certificates Hygienic certificates for the ARPANEL sandwich panels with the core can be downloaded from the website The hygienic certificates for the sandwich panels with PUR/ PIR and MiWo cores have been issued by the National Public Health Institute - National Hygiene Institute. 128 Hygienic certificates

Product range ROMA INSULATION SYSTEMS. Everything you need to know about ROMA and our products in one document.

Product range ROMA INSULATION SYSTEMS. Everything you need to know about ROMA and our products in one document. ROMA INSULATION SYSTEMS Product range Everything you need know about ROMA and our products in one document.» Individual solutions from ROMA are developed by competent employees who understand the needs

More information

TECHNICAL SOLUTIONS CATALOGUE CONTENTS

TECHNICAL SOLUTIONS CATALOGUE CONTENTS TECHNICAL CATALOGUE GORLICKA S / GORLICKA S GS-PIR TECHNICAL SOLUTIONS CATALOGUE CONTENTS I. GENERAL INFORMATION Introduction 2 About the company 2 About the product 2 Structure of panels 2 Certificates

More information

Hoesch isodach integral Technical information

Hoesch isodach integral Technical information Technical information A company of ThyssenKrupp Steel tk Contents Page General 3 Main dimensions and properties 4 Corrosion protection 5 Thermal protection / Insulating core 5 Fire protection 5 Information

More information

TECHNICAL SOLUTIONS CATALOGUE CONTENTS

TECHNICAL SOLUTIONS CATALOGUE CONTENTS COLDSTORE CATALOGUE GORLICKA CH / GORLICKA CH GS-PIR TECHNICAL SOLUTIONS CATALOGUE CONTENTS I. GENERAL INFORMATION Introduction 2 About the Company 2 About the product 2 Structure of panels 2 Certificates

More information

Insulated Panel System. QuadCore IND. Superior FIRE Protection. Unrivalled THERMAL Efficiency. ENHANCED Environmental Credentials

Insulated Panel System. QuadCore IND. Superior FIRE Protection. Unrivalled THERMAL Efficiency. ENHANCED Environmental Credentials 1 Superior FIRE Protection 2 Unrivalled THERMAL Efficiency 3 ENHANCED Environmental Credentials 4 Longest Performance GUARANTEE Insulated Panel System QuadCore IND Technical Information Projet / Usage

More information

Sandwich panel SPA Product description

Sandwich panel SPA Product description Sandwich panel SPA Product description Ruukki offers a sandwich panel system that combines an attractive appearance with excellent thermal insulation and fire-resistance. The panels are of a lightweight,

More information

Insulated Panel Systems. 1, d0 IND E N 1350

Insulated Panel Systems. 1, d0 IND E N 1350 Insulated Panel Systems DING TO OR 1, d0-1 ACC IND E N 1350 1 Project: TransWest nv, Kampveldstraat 45, 8020 Oostkamp, Belgium Use: Logistical platform with a negative temperature Technical Information

More information

RAW MATERIAL. source: ABCEM

RAW MATERIAL. source: ABCEM METAL TILES RAW MATERIAL Raw Material: steel coated The Brazilian steel industry is today among the largest and most modern in the world, being able to meet the most rigorous specifications of steel, of

More information

Façade System Trimoterm FTV INVISIO

Façade System Trimoterm FTV INVISIO Façade System Trimoterm FTV INVISIO Technical document No. 6/ Version / October 0 CONTENT.0 Technical description of the Facade system with Hidden Fixing - INVISIO []. General []. Panel profile []. Panel

More information

Fire protection, soundproofing and thermal insulation

Fire protection, soundproofing and thermal insulation ROMA INSULATION SYSTEMS Fire protection, soundproofing and thermal insulation Quick-assembly insulating panel, types FP, FV and FP Acoustic 02 ROMA quick-assembly insulating panel, types FP and FP+ Cladding

More information

RUUKKI FORMA DESIGN INSTRUCTION

RUUKKI FORMA DESIGN INSTRUCTION www.ruukki.com RUUKKI FORMA DESIGN INSTRUCTION 1. General Ruukki Forma is a complete façade system in which Ruukki energy panels form an energy efficient base structure and Ruukki cladding products finalize

More information

INSULATED PANELS. Cold Store

INSULATED PANELS. Cold Store INSULATED PANELS Cold Store Table of Contents 0 03 05 06 07 3 5 6 7 9 3 5 7 Introduction Production Technology EIP Panel Benefits Products Material Specifications Applications Dimensions, Weight & Thermal

More information

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Xtratherm Thin-R Thermal Liner (XT/TL Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 4 Xtratherm Thin-R Thermal Liner (XT/TL Grade) PRODUCT DESCRIPTION: This Detail Sheet relates to Xtratherm Thin-R Thermal Liner, as defined in NSAI Agrément Certificate

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV

More information

COMP ONENT CATA LO GUE FOR INDUSTRIAL BUILDINGS

COMP ONENT CATA LO GUE FOR INDUSTRIAL BUILDINGS M a d e f o r b u i l d i n g b u i l t f o r l i v i n g COMP ONENT CATA LO GUE FOR INDUSTRIAL BUILDINGS I M P R i n t KLH Massivholz GmbH Publisher and responsible for the content: KLH Massivholz GmbH

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco

More information

Cold Rooms Kide

Cold Rooms Kide COLD ROOMS Cold Rooms 2 Cold under control KIDE it is a business Group manufacturer of cold-rooms, insulation panels, insulated doors, refrigeration units and drying units, offering integral solutions

More information

Now our house. saves soooo. much energy! T h e N e w G e n e r a t i o n Energy Saving. S y s t e m. The Quality Profile

Now our house. saves soooo. much energy! T h e N e w G e n e r a t i o n Energy Saving. S y s t e m. The Quality Profile Now our house saves soooo much energy! T h e N e w G e n e r a t i o n Energy Saving S y s t e m The Quality Profile based on our new SOFTLINE 82 profile system improve the energy efficiency of just any

More information

Roofing. Sarnafil G EL Felt. Polymeric membrane for roof waterproofing. Product Description

Roofing. Sarnafil G EL Felt. Polymeric membrane for roof waterproofing. Product Description Roofing Product Data Sheet Edition 10.2012 Identification no: 02 09 01 01 341 0 120000 Version no. 06 Sarnafil G 410-12EL Felt Polymeric membrane for roof waterproofing Product Description Sarnafil G 410-12EL

More information

Presentation of prefabricated houses. - Main equipments. - Assembly steps. - Some realisations

Presentation of prefabricated houses. - Main equipments. - Assembly steps. - Some realisations Prefabricated Houses Presentation of prefabricated houses - Employed components - Main equipments - Assembly steps - Some realisations SKA spa via Agosta, 3-36066 Sandrigo (VI) - Italy - Tel. + 39 0444

More information

EasylationWall. External Wall Insulation System. bringing european innovation

EasylationWall. External Wall Insulation System. bringing european innovation EasylationWall External Wall Insulation System bringing european innovation EasylationWall... the new External Wall Insulation System using brick slips for stunning façades. EXTERNAL WALL INSULATION (EWI)

More information

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products. GypLyner GypLyner Metal framed wall lining system All our systems are covered by SpecSure when using genuine Gyproc and Isover products Linings GypLyner GypLyner is a cost-effective, virtually independent

More information

D Side lap. Side lap screw spacing < 500mm factory-installed seals on side lap. Decoupling tape > 60mm

D Side lap. Side lap screw spacing < 500mm factory-installed seals on side lap. Decoupling tape > 60mm 25 Side lap screw spacing < 500mm 333.3 15 42 Decoupling tape > 60mm 3 factory-installed seals on side lap Side lap D 201.1 SECTION VIEWS Type L Ridge profile Type R Ridge flashing FLOOR PLAN > 200 overlap

More information

Kingspan Day-Lite Kapture Data Sheet

Kingspan Day-Lite Kapture Data Sheet Light + Air UK & Republic of Ireland Kingspan Day-Lite Data Sheet KS700DLK, KS1400DLK, KS0DLK 2 Kingspan Day-Lite KS700DLK, KS1400DLK, KS0DLK Application KS700DLK, KS1400DLK, KS0DLK & KS2750DLK rooflights

More information

HOME & BUSINESS IMPROVEMENTS BE CLEVER... BE SAFE... BROCHURE 2017

HOME & BUSINESS IMPROVEMENTS BE CLEVER... BE SAFE...  BROCHURE 2017 HOME & BUSINESS IMPROVEMENTS BE CLEVER... BE SAFE... COMPOSITE STEEL DOORS GERMAN VEKA PVC / ALUMINIUM WINDOWS & DOORS INSULATED SECURITY SHUTTERS GARAGE DOORS RETRACTABLE GRILLES SUN PROTECTION WINDOW

More information

Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description

Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description January, 2009 Sarnafil TS 77-15 Polymeric membrane for roof waterproofing Construction Product Description Uses Characteristics / Advantages Approval / Standards Sarnafil TS 77-15 (thickness 1.5 mm) is

More information

Kingspan Day-Lite Klick

Kingspan Day-Lite Klick Insulated Panel Envelope Systems Roof Wall Façades Lighting Rooftop PV Coldstore Structural Products Cleanrooms UK & Ireland Kingspan Day-Lite Klick Installation Guide Page 2 Accessories Overview Designation

More information

TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED EXTERNAL WALL PANEL TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED EXTERNAL WALL PANEL

TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED EXTERNAL WALL PANEL TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED EXTERNAL WALL PANEL TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED ConquererTM Panel Products Introduction ConquerorTM International Ltd is New Zealand s only manufacturer

More information

Construction. Sarnafil G Felt. Polymeric membrane for roof waterproofing. Product Description

Construction. Sarnafil G Felt. Polymeric membrane for roof waterproofing. Product Description Roofing Product Data Sheet Edition 03.2012 Identification no: 02 09 05 05 215 0 120000/1 Version no. 01 Sarnafil G 410-12 Felt Polymeric membrane for roof waterproofing Construction Product Description

More information

Translation from German (14 pages in all) Translation of the German original version not revised by the Deutsches Institut für Bautechnik

Translation from German (14 pages in all) Translation of the German original version not revised by the Deutsches Institut für Bautechnik Translation from German (14 pages in all) Translation of the German original version not revised by the Deutsches Institut für Bautechnik National Deutsches Institut für Bautechnik 1 Technical ANSTALT

More information

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,

More information

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description Roofing Product Data Sheet Edition 02.2015 Identification no: 02 09 01 01 201 0 120000 Version no. 04 Sarnafil S 327-12EL Polymeric membrane for roof waterproofing Product Description Sarnafil S 327-12EL

More information

The most flexible, reliable, versatile and cost effective roofing material

The most flexible, reliable, versatile and cost effective roofing material The most flexible, reliable, versatile and cost effective roofing material Onduline roofing made easy Onduline is an extremely tough, lightweight, corrugated roofing and wall cladding material manufactured

More information

Roofing. Polymeric sheet for roof waterproofing. Product Description. Tests. Product Data Sheet Edition _1

Roofing. Polymeric sheet for roof waterproofing. Product Description. Tests. Product Data Sheet Edition _1 Product Data Sheet Edition 2014-09_1 Polymeric sheet for roof waterproofing Product Description (thickness 1.5 mm) is a Polyester reinforced, multi-layer, synthetic roof waterproofing sheet based on premium-quality

More information

FACADE PROFILES FOR VERSATILE APPLICATIONS 01/16

FACADE PROFILES FOR VERSATILE APPLICATIONS 01/16 FACADE PROFILES FOR VERSATILE APPLICATIONS 01/16 EDGE FORMATION JOINT STRUCTURE CONNECTION STRUCTURE REVEAL FORMATION ROOF AND FACADE VENTILATION CUSTOM SOLUTIONS PRODUCT RANGE According to item number

More information

World s best-performing glass curtain wall

World s best-performing glass curtain wall World s best-performing glass curtain wall CONTENT Qbiss - Quality Building Innovative Smart Skin 1 Superior Energy Efficiency 2 Ultimate Aesthetics 4 Living and Working Comfort 6 Single Skin for Double

More information

Insulated Panels. Insulated Roof Systems. Kingspan X-dek. KS1000 XD Longspan Roofpanel. Systems. Insurer Approved

Insulated Panels. Insulated Roof Systems. Kingspan X-dek. KS1000 XD Longspan Roofpanel. Systems. Insurer Approved Insulated Panels 02 2010 Insulated Roof Systems Kingspan X-dek KS1000 XD Longspan Roofpanel Insurer Approved Systems X dek TM Frame-to-Frame Long Spanning Insulated Roof Deck X dek TM is an insulated roof

More information

Light steel framing.

Light steel framing. Light steel framing www.be-steel.eu advantages of a light steel framing Light steel framing technology, also known under the name of cold-formed steel structures, is a construction technique that is already

More information

Corium Brick Rainscreen System Specifications

Corium Brick Rainscreen System Specifications CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

For F-1 top side of the panel trapezoidal roll formed sheets TR 40/250 are used, and for F-2 side TR 1.5/66.67.

For F-1 top side of the panel trapezoidal roll formed sheets TR 40/250 are used, and for F-2 side TR 1.5/66.67. CONTENTS. INTERLEMIND KP roof panels - technical description..... Introduction..... Roof panel shape..... Roof panels structure..... Technical data..... Static capacity... 6.6. Fixing elements... 8 -Rafters...

More information

Project s fiche INOV. Frisomat Case study project's fiche INOV

Project s fiche INOV. Frisomat Case study project's fiche INOV Project s fiche INOV Clear Flatro building 49 metres long The Flatro industrial building in Villers-le-Bouillet measures 15 metres by 49 metres and is 6 metres high. The building rests on concrete plinths

More information

ACM. Product Data Sheet

ACM. Product Data Sheet ACM Benchmark Aluminium Composite Material (ACM) façade system, is available in three cassette options and installed on a specifically designed Benchmark. Images above courtesy of Alucobond FAÇADE DATA

More information

Sound-absorbing and sound-insulating barriers

Sound-absorbing and sound-insulating barriers Sound-absorbing and sound-insulating barriers innovative and biocompatible solutions for the environment sound-insulation Sound-absorbing and sound-insulating noise barriers for road and rail traffic are

More information

Aluminum Honeycomb Panel

Aluminum Honeycomb Panel Aluminum Honeycomb Panel ABOUT US Universal Metaltek is one of biggest Indian company established for manufacturing, trading, imports and exports of various types of engineering items having a wide portfolio

More information

Weatherproofing & Sealing Systems

Weatherproofing & Sealing Systems Weatherproofing & Sealing Systems Weather Barrier & Waterproofing Residential & Commercial Structures New Construction, Remodeling & Repair Low Slope Roofing Membranes Roofing Underlayments Window & Door

More information

Technical data sheet Number 04 / updated November 2008

Technical data sheet Number 04 / updated November 2008 Metal ceilings and corrosion protection Information for building designers, installers and system manufacturers Contents 1. General information regarding metal ceilings and corrosion protection 2 2. Technical

More information

mounting systems applications overview

mounting systems applications overview mounting systems applications overview catalogue version January 2015 tritec mounting systems: overview of applications i. pitched roof: roof-top 1. Tiles, shingles and corrugated panels 1.1 TRI-STAND

More information

TOTAL INSULATION ROOFS ROOFS WALLS WALLS FLOORS. Energy efficiency for construction projects Always in harmony with the environment.

TOTAL INSULATION ROOFS ROOFS WALLS WALLS FLOORS. Energy efficiency for construction projects Always in harmony with the environment. TOTAL INSULATION ROOFS ROOFS WALLS WALLS FLOORS Energy efficiency for construction projects Always in harmony with the environment www.prodexcr.com PRODUCT DESCRIPTION: Prodex is a reflective thermal insulation

More information

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 1 Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) PRODUCT DESCRIPTION This Detail Sheet relates to Xtratherm Thin-R Partial Fill Cavity Wall Board, as

More information

Olympia is recognized as one of the industry leaders in providing superior quality, service and durability at low prices.

Olympia is recognized as one of the industry leaders in providing superior quality, service and durability at low prices. 40 Our buildings are manufactured entirely in the United States and include a 40-year limited rust-through perforation warranty on AZ55 Galvalume roof panels. Olympia is recognized as one of the industry

More information

Real Brick Cladding. Iso Klink Pur. Brick Panel System Catalogue

Real Brick Cladding. Iso Klink Pur. Brick Panel System Catalogue Iso Klink Pur Brick Panel System Catalogue 1 BRICK CLADDING PANEL SYSTEM Combination of high performance pur insulation and brick cladding, creating durable and aesthetic system which is quick and easy

More information

CLCF Climate Changer for comfort applications. Next generation air handling performance from Trane

CLCF Climate Changer for comfort applications. Next generation air handling performance from Trane CLCF Climate Changer for comfort applications Next generation air handling performance from Trane Customized performance and maximum comfort at minimum cost For many years Trane has been a global leader

More information

Product Data Sheet. QuadCore Karrier. Applications

Product Data Sheet. QuadCore Karrier. Applications Applications The Quad Karrier system is face fixed, provides the support, thermal and weathering functions to the Benchmark facades. The panel can be laid horizontally or vertically. Suitable for all building

More information

LUX Specifications. Section S - Preformed Steel Siding

LUX Specifications. Section S - Preformed Steel Siding Part 1 General.1 System-1: Installation over building paper or air barrier membrane, on exterior grade gypsum board or exterior grade wood sheathing. 1.2 RELATED SECTIONS.1 Section 01 11 00 Summary of

More information

GREENHOUSE ENGINEERING PREFABRICATED HOUSES

GREENHOUSE ENGINEERING PREFABRICATED HOUSES GREENHOUSE ENGINEERING PREFABRICATED HOUSES WOODEN HOUSES Prefabricated wooden houses are made of wooden bearing structure with mineral wool, with a vapor barrier. On the inside, construction is lining

More information

Technical Guide. PAROC panel solutions

Technical Guide. PAROC panel solutions Technical Guide PAROC panel solutions Panel System.0 INT May 0 PAROC FIRE PROOF PANELS The technical data and recommendations included in this Technical Guide are based on EN 09 Self-supporting double

More information

Thermal Laminate Board.

Thermal Laminate Board. Thermal Laminate Board www.speedlinedrywall.co.uk The Dry Lining and Thermal Insulation Solution The Dry Lining and Thermal Insulation Solution Around a third of all heat lost within un-insulated or poorly

More information

INDUSTRIALIZED CONSTRUCTION BRASILIT FIBER CEMENT BOARD, PANELS AND ACCESSORIES FOR THE EXECUTION OF YOUR CONSTRUCTION

INDUSTRIALIZED CONSTRUCTION BRASILIT FIBER CEMENT BOARD, PANELS AND ACCESSORIES FOR THE EXECUTION OF YOUR CONSTRUCTION INDUSTRIALIZED CONSTRUCTION BRASILIT FIBER CEMENT BOARD, PANELS AND ACCESSORIES FOR THE EXECUTION OF YOUR CONSTRUCTION Make it Easier with Brasilit BRASILIT FIBER CEMENT BOARDS AND PANELS. QUICKNESS AND

More information

ENERGY EFFICIENT BUILDING STRUCTURE. ...more than brick.

ENERGY EFFICIENT BUILDING STRUCTURE. ...more than brick. ENERGY EFFICIENT BUILDING STRUCTURE...more than brick. ABOUT US Our company manufactures and distributes revolutionary products that provide solutions world-wide to the greatest challenges of the construction

More information

Product Data Sheet. Product: Benchmark Wall Liner System

Product Data Sheet. Product: Benchmark Wall Liner System APPLICATION The Benchmark Wall Liner system is to be used as an insulated composite wall panel under site applied fully supported or self-supported aluminium, copper, zinc and stainless steel cladding

More information

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.

More information

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION MANUFACTURED ROOF EXPANSION JOINTS SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS Controlled Environments Controlled Environment Panel System KS1100 CS Overview Kingspan controlled environment panel systems are designed for use within temperature controlled and hygiene safe environments

More information

SEPLUX 40 5PX. Polycarbonate interlocking panel system

SEPLUX 40 5PX. Polycarbonate interlocking panel system CLEARDEK SEPLUX 40 5PX Polycarbonate interlocking panel system commitment Technical Characteristics Multiwall triple-wall panel in co-extruded polycarbonate, UVprotected on one side, with 10 YEARS GUARANTEE

More information

Introducing TJ Insulated Structural Framing Components

Introducing TJ Insulated Structural Framing Components #TJ-9009 SPECIFIER S GUIDE TJ INSULATED HEADERS, RIM BoaRD, AND CORNERS Introducing TJ Insulated Structural Framing Components Helps meet the 2011 Federal Energy Star Homes and 2009 International Energy

More information

Flashings TYPICAL SHAPES AND JOINTS

Flashings TYPICAL SHAPES AND JOINTS CONTENTS PAGE Also available Flashings Rainwater Components Facades & Rainscreen Panels 1-4 5-6 7-10 Bullnoses & other Architectural Features 11-14 Louvres 15-16 Materials 17 Colour Charts 18 Our Premises

More information

Perfect technology with design. Hoesch Sectional door elements

Perfect technology with design. Hoesch Sectional door elements Perfect technology with design Hoesch Sectional door elements hoesch sectional door elements content 2 for more than three decades, thyssenkrupp Bausysteme has been one of the market leaders in cutting-edge

More information

ifix INSTALLATION MANUAL PV flat roof installation system Version

ifix INSTALLATION MANUAL PV flat roof installation system Version ifix PV flat roof installation system INSTALLATION MANUAL Version 2012-09-06 ifix Installation Manual Version 2012-09-06 Seite 1 Table of contents Table of contents... 1 Special characteristics of ifix...

More information

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board Member of Kiwa Nederland B.V. www.eota.eu Sir Winston Churchilllaan 273 NL-2288 EA Rijswijk Postbus 70 NL-2280 AB Rijswijk Tel.: +31 (0)88 998 44 00 Fax: +31 (0)88 998 44 20 E-mail: info@kiwa.nl European

More information

Product Data Sheet. UltraTemp Insulated Panels for Chilled Storage Applications with a Temperature Range of 0 C to +5 C KS1100 CS

Product Data Sheet. UltraTemp Insulated Panels for Chilled Storage Applications with a Temperature Range of 0 C to +5 C KS1100 CS Product Data Sheet UltraTemp Insulated Panels for Chilled Storage Applications with a Temperature Range of 0 C to +5 C Product Data Sheet Applications UltraTemp insulated roof, wall and ceiling panels

More information

SoftWall Partitions and Curtains

SoftWall Partitions and Curtains SoftWall Partitions and Curtains The Ultimate in Cost- Effective Flexibility An Excellent Alternative to Rigid Wall Construction An Excellent Alternative Soper s Softwall Enclosures are easy to install,

More information

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution Insulated Panels North America Universal Barrier Wall Solution 2 Universal Barrier Wall Solution About is a cost effective universal barrier wall alternative solution to traditional multicomponent wall

More information

One and Two Family Additions

One and Two Family Additions One and Two Family Additions An addition to a house, duplex, garage, or an accessory structure requires a building permit prior to performing any construction. Building Department & Permit Office Mon-Fri

More information

OSB.COMFORT INSTALLATION GUIDE * 1 RECOMMENDED USE PANEL COMPOSITION

OSB.COMFORT INSTALLATION GUIDE *  1 RECOMMENDED USE PANEL COMPOSITION STYRO RAIL 07-0 Expanded Polystyrene Rigid Insulation combined to an Oriented Structural Board INSTALLATION GUIDE * 9 mm [8 ] The OSB.Comfort boards manufactured by Styro Rail are composed of type expanded

More information

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1 Louis Armstrong New Orleans International Airport NOAB Project # 8910-01233 PART 1 - GENERAL SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

SECTIONAL GARAGE DOORS

SECTIONAL GARAGE DOORS SECTIONAL GARAGE DOORS 7 1 ULTIMATE LIFESPAN OF DOOR SPRINGS Ultimate service life of springs is guaranteed, this means the door can run up and down up to 25,000 times.this is equivalent to 17 years of

More information

PRODUCT BROCHURE ARCHITECTURAL FABRICATIONS

PRODUCT BROCHURE ARCHITECTURAL FABRICATIONS ARCHITECTURAL FABRICATIONS PRODUCT BROCHURE Feature Beam Anodised Products Rainscreen Panels Fascia Panels & Soffits Ultima Insulated Panels Perforated Panels Cills, Fins & General Pressings Column Covers

More information

PROFILE S6 CORRUGATED SHEETS

PROFILE S6 CORRUGATED SHEETS PROFILE S6 CORRUGATED SHEETS CONTENT 02 04 06 The ideal corrugated sheet exists Why choose PROFILE S6 corrugated sheets Colours 07 Range 08 Accessories 10 Pre-grooved/ mitred corners The ideal corrugated

More information

Sapphire Metal Tile Roofing System

Sapphire Metal Tile Roofing System Sapphire Metal Tile Roofing System Sapphire Metal Tile Roofing Benefits of Sapphire Metal Tile - Beauty and function - Tile Beauty, Steel Strength, Lasts a lifetime - Excellent long term investment - Pays

More information

AKRAPLAST Sistemi S.p.A. - I Novate Milanese (Mi) - via Cascina del Sole, 70 Tel: (+39) Fax: (+39)

AKRAPLAST Sistemi S.p.A. - I Novate Milanese (Mi) - via Cascina del Sole, 70 Tel: (+39) Fax: (+39) The anchorage of the polycarbonate panels is accomplished mainly by locking the polycarbonate clip profile into the steel channel. The particular shape of the panels and the special profile of the steel

More information

European Technical ETA-04/0023 Assessment of 17 October 2017 General Part

European Technical ETA-04/0023 Assessment of 17 October 2017 General Part European Technical Assessment ETA-04/0023 of 17 October 2017 - Original version in German language General Part Technical Assessment Body issuing the European Technical Assessment: Trade name of the construction

More information

SPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide

More information

Industry Standard Terms & Definitions Of The Steel Deck Institute

Industry Standard Terms & Definitions Of The Steel Deck Institute Industry Standard Terms & Definitions Of The Steel Deck Institute A specialized set of jargon to describe common terms used by manufacturers and other professionals associated with the usage of Steel Deck

More information

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer) NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION MASTERFORMAT SECTION 04818 (Mortarless Concrete Brick Veneer) Spec_USA_En_18102005.doc 12/1/2005 Novabrik Page 2 Section 04818 NOVABRIK MORTARLESS

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2218 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 07 00

More information

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS SECTION 07 42 13.26 PART 1 - GENERAL 1.01 SECTION INCLUDES A. Zinc alloy metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.

More information

PORTISO is a company dedicated to the manufacturing of isothermal doors built to satisfy the different needs of any industrial sector.

PORTISO is a company dedicated to the manufacturing of isothermal doors built to satisfy the different needs of any industrial sector. PORTISO is a company dedicated to the manufacturing of isothermal doors built to satisfy the different needs of any industrial sector. We have modern manufacturing facilities in France, UK and Portugal,

More information

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS INTRODUCTION BENCHMARK Wall Liner is an engineered insulated panel system that is ideal for fully supporting single skin metal sheeting such as zinc,

More information

DICTATOR Lift Shaft System

DICTATOR Lift Shaft System DICTATOR Lift Shaft System The Modular Lift Shaft System, also for Retrofitting Certified According to EN 1090 A lift is becoming more and more important for daily life, not only in newly constructed buildings

More information

ITB TECHNICAL APPROVAL AT /2012. XPS extruded polystyrene Panel-Base Products

ITB TECHNICAL APPROVAL AT /2012. XPS extruded polystyrene Panel-Base Products CERTIFIED TRANSLATION FROM POLISH [logo] BUILDING RESEARCH INSTITUTE [ITB] P L 0 0-6 1 1 W A R S Z A WA, u l. F I L T R O WA 1 tel.: (48 22) 825-04-71 ; (48 22) 825-76-55 - fax: (48 22) 825-52-86 T h e

More information

Products PVC-ALU-WOOD

Products PVC-ALU-WOOD ducts PVC-ALU-WOOD Products PVC-ALU-WOOD Products PVC-ALU-WOOD Products PVC-ALU-WOOD Products PVC-ALU-WOOD Products PVC-A Products PVC-ALU-WOOD PVC PROFILES Ideal 4000 02 5 chamber system 70 mm depth Uw

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC. 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1143 Reissued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00 THERMAL

More information

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Part 1 General 1. RELATED SECTIONS 1. Section 07 92 10 Joint Sealing 2. Section 08 71 00 Door Hardware 2. REFERENCES 1. American Society

More information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017 SECTION 10505 - METAL STUDENT LOCKERS PART 1 - GENERAL 1.01 SCOPE OF WORK A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral

More information

MILT-Pro. Built-in units and control centres for halls

MILT-Pro. Built-in units and control centres for halls MILT-Pro Built-in units and control centres for halls Space The MILT-Pro built-in units provide its design solution offer a large range of applications in commercial, manufacturing and warehouse spaces.

More information

60 years. of progressive development

60 years. of progressive development Dencroft has been providing a wide range of sectional buildings for over 60 years, making us one of the most experienced designers and manufacturers of quality garages in the UK. Innovation has played

More information

THERMO SOLUTION. Ceramic Thermal Insulating Coating

THERMO SOLUTION. Ceramic Thermal Insulating Coating THERMO SOLUTION Ceramic Thermal Insulating Coating 2014 What is Thermo Solution? THERMO SOLUTION is an ecologic coating based on ceramic nanospheres exhibiting excellent thermal insulation properties.

More information