Hepburn & Associates Independent Chartered Building Surveyors. 66 The Street The Town Kent XX1 2XX BUILDING SURVEY

Size: px
Start display at page:

Download "Hepburn & Associates Independent Chartered Building Surveyors. 66 The Street The Town Kent XX1 2XX BUILDING SURVEY"

Transcription

1 Independent Chartered Building Surveyors 66 The Street The Town Kent XX1 2XX BUILDING SURVEY Mr & Mrs Good Client Present Address The Town Kent XX1 2XX 04 March 2011 Ref: RFH/xxxx/BS Regulated by RICS

2 CONTENTS INTRODUCTION.4 Name and Address of Client 4 Property Address.4 Council Tax Band.4 Date of Inspection.5 Weather.5 Limits of Inspection.5 SITUATION AND DESCRIPTION...6 Property type.6 Accommodation.6 Outbuildings and parking 7 Approximate age.7 Orientation.7 Location and amenities 7 Tenure.7 Summary of construction 8 COMMENTS ON CONSTITUENT ELEMENTS 8 Chimney stacks.8 ROOFS.9 External Areas.9 Roof Space.12 Rainwater Goods.13 WALLS.14 EXTERNAL JOINERY..18 EXTERNAL DECORATIONS..19 CEILINGS, WALLS, PARTITIONS AND FINISHES 20 Ceilings 20 Internal Walls & Partitions 21 CHIMNEY BREASTS, FLUES AND FIREPLACES. 22 FLOORS 23 DAMPNESS 25 INTERNAL JOINERY...26 TIMBER DEFECTS 27 2 of 46

3 INTERNAL DECORATIONS..29 CELLARS AND VAULTS.. 29 THERMAL EFFICIENCY..29 OTHER MATTERS 30 Security 30 Fire Precautions 30 SERVICES 32 Electricity 32 Gas 33 Plumbing and Heating..34 Sanitary Fittings 37 Drainage 37 EXTERNALLY 38 Garages and Outbuildings..38 Site 39 GENERAL 40 Points for your Legal Advisor to Check 40 Roads and Planning 41 CONCLUSIONS 42 PREVENTATIVE MAINTENANCE NOTES. Appendix A DIAGRAM OF A TYPICAL HOUSE. Appendix B PHOTOGRAPHS... Appendix C GLOSSARY OF BUILDING TERMS..Appendix D 3 of 46

4 INTRODUCTION Hepburn & Associates Further to your written instructions of xx January 2011 we have now undertaken a Building Survey of the above property. The report has been prepared in accordance with our Conditions of Engagement and should be regarded as a comment on the overall condition of their property and the quality of its structure and not as an inventory of every single defect. It relates to those parts of the property, which were reasonably and safely accessible at the time of inspection, but you should be aware that defects could subsequently develop. The report should be construed as a comment upon the overall condition of the property and not as an inventory of every single defect, some of which would not significantly affect the value of the property. We had not inspected the building during its recent lifespan and therefore it is not possible for us to comment on the workmanship in areas that are now covered, or otherwise concealed. Your legal advisor should confirm that all necessary statutory approvals have been obtained and the works were supervised and checked for compliance with statutory requirements. Name and Address of Client Mr & Mrs Client Present Address The Village Kent XX1 1XX Property Address Victorian House The Town Kent XX1 2XX Council Tax Band 4 of 46

5 The agent s details do not indicate the tax band. This can be checked and confirmed with the local authority can advise on the level of local taxation. Date of Inspection The property was inspected on Monday xx January Weather The weather over time of inspection was dry but overcast. This follows a relatively settled period of weather. Limits of Inspection The property was unoccupied but with the floor coverings laid in the hall and kitchen areas, and consequently our inspection has been limited in some respects. As will be appreciated, an inspection of areas covered by floor coverings will only be possible once the property has been fully cleared and vacated. You should appreciate that due to the nature of this report as a pre-purchase investigation, we have not been able to inspect woodwork, brickwork or other parts the property or its services, which are covered, unexposed or inaccessible, and we are therefore unable to report that such parts of the property are free from defect. You should be aware that defects could develop or become worse in a property after the date of inspection, particularly if not well maintained. This report is based on the condition of the property at the time of our inspection and no liability can be accepted for any deterioration in its condition after this date. Where defects are described in his report, in many cases their extent can only be fully obtained upon further investigation or by carrying out of repairs. Further investigation of defects may be necessary before costings can be produced. Also is possible that concealed defects may become apparent at this stage. Consequently it is recommended of that, where possible, any further investigation be undertaken before the legal commitment to purchase. The vendors express written consent would be necessary in respect of any further investigation works carried out prior to purchase and allowance should be made for 5 of 46

6 reinstatement works should you not proceed. The report must be read as a whole and although we have stressed certain items which we consider as essential, other items in this report must not be neglected. Any figure of course provided within this report or given verbally is a rough guide only and should not be taken as a firm estimate. It is very strongly advised that competitive estimates be obtained from suitably qualified and experienced builders or specialists in respect for defects or works of repair, as described in this report, prior to agreeing a purchase price and legal commitment to purchase. The carry out of repairs may result in associated rectification works e.g. reinstatement of services. It should be appreciated that there may be other matters of a personal choice which will involve expenditure in the future, such as modernisation of fittings and furnishing. SITUATION AND DESCRIPTION Property type The subject property comprises a Victorian two storey mid terraced house with a two storey rear projection and a single storey outbuilding to the rear. We understand that you are buying the property as an investment, presumably to let the property or for immediate resale following full scale refurbishment. We have therefore indicated areas where improvements can be made at reasonable cost to maximise rental income or improve saleability and therefore resale value. Accommodation The client is assumed to have inspected the accommodation and found it suitable for their purposes. The following is therefore only a brief description: - Ground floor: - Hall, Living Room, Kitchen/Diner, Rear lobby, Bathroom (Bath, WC and shower cubicle. First floor: - Three bedrooms (the third accessed off of the second bedroom). The estate agents sales particulars, including room sizes, have not been checked for accuracy. 6 of 46

7 Outbuildings and parking Hepburn & Associates There is a single storey outbuilding to the rear of the bathroom area which used to form the external WC and fuel store. The dividing partition has been removed. There is no garage the only parking is in the road outside the property. The road is relatively narrow and parking close to the property at peak times, evenings and weekends may be more difficult due to the close proximity of the local shops and amenities. Approximate age We estimate that the property dates from around the turn of the century and is therefore in the region of 110 years of age. Orientation Directions are given as both facing the front elevation and descriptions of the building may be given as left and right. Location and amenities The property is located in an established residential area within easy reach of local amenities. Fuller facilities are available within 5 miles and the property has good access to the M20 and M2 motorways. Tenure We understand that the property is to be sold freehold and with vacant possession available on completion. Your legal advisor should confirm whether this is the case. 7 of 46

8 Summary of construction Hepburn & Associates Walls: The external walls are of traditional nine inch (225mm) solid masonry construction with an external rendered coating of pebble dash render finished in masonry paint decoration. Roof: The roof is of pitched timber construction covered with a replacement covering of concrete interlocking tiles. Windows: Windows have been mainly replaced in basic quality Upvc double glazed units situated directly into brickwork surrounds. COMMENTS ON CONSTITUENT ELEMENTS Chimney stacks Chimney stacks have been inspected from ground level only within the limitations of the site area and ground levels. The stability and condition of chimney stacks, flashings and chimney pots etc., can only be ascertained by close inspection from long extension ladders. Such an inspection may reveal concealed defects, possibly instability. Not all chimney stack elevations could be seen from ground level or relevant vantage points. Chimney stacks can be weakened by storms and are prone to frost attack. Repairs can be necessary periodically as part of normal maintenance. As you will appreciate, the internal condition of chimney stacks and flues cannot be ascertained from an external inspection. Flues should be swept prior to use. There is a chimney stack to the right hand party wall penetrating the ridge shared with the adjoining property. The stack is adequately upright and the brickwork and pointing in fair condition showing only normal weathering. Where the stack penetrates the roof covering an adequate lead flashing has been provided. Whilst there is some evidence of old staining internally below the flashing there is no evidence of recent leakage which indicates that the flashing is in satisfactory functioning order. Proposed repairs to shared chimney stacks should be carried out following consultation with adjoining owners. In buildings of this age chimney stacks did not usually incorporate a damp proof course within the structure where they penetrate the roof covering. As a consequence damp can penetrate downwards through the brickwork if not well maintained making 8 of 46

9 adjoining timbers vulnerable to decay. Good maintenance of the pointing and flashing is therefore essential. The chimney stack to the left hand party wall serves the adjoining property only but again the flashing where it abuts the subject properties roof covering appeared to be in good order and no internal leakage was noted. There would have been a chimney stack to the rear left corner of the rear projection. This has been removed and the roof covering extended over. From what could be seen from the limited view from ground level this appears to have been carried out at the time of recovering of the roof. Internally the remainder of the chimney breast has been removed from the upper bedroom and roof space above. However please see our later comments concerning the rear wall of Bedroom 3 where there is now only a section of single skin brickwork which will be prone to dampness and condensation problems. This chimney breast would have been unlikely to have been taken down to the ground floor room being corbelled out at ceiling level. However within the kitchen no evidence of any remaining chimney breast or infill was visible. This flue would have served a fireplace within the third bedroom and a copper flue from the kitchen (now the bathroom). It is good practice to fit cowls and internal vents to disused flues so as to prevent rain running down the flues. Through ventilation of disused flues is essential otherwise dampness can occur in the chimney breasts. We did note that the flues have the original chimney pots and have not been capped or fitted with cowls. Please see later comments concerning the internal air ventilation to disused flues under the main Chimney Breast heading within the internal aspect of this report. Aerials secured to chimney stacks should be checked periodically from long ladders for evidence of corrosion and weakness. The masonry to which the aerial is secured should be checked. Tall aerials in particular can exert significant stresses in the chimney stack brickwork during high winds. Obviously roof coverings can be damaged should an aerial fall and there is potential for personal injury. ROOFS External Areas 9 of 46

10 Roof slopes have been inspected from ground level only within the limitations of the garden area and height of the building. The condition of any concealed areas can only be ascertained using long builders ladders. Pitched roof coverings have been inspected from ground level only with the aid of binoculars within the limitations of the surrounding area and the height of the buildings. We cannot confirm the condition and freedom from defect of concealed areas invisible from ground level. Inspection of such areas, where they may exist, can only be carried out using long builder s ladders. Only a limited view of the rear apex section was possible from ground level. Inspection of the roof tiles was limited to the exterior because of the bituminous roofing felt laid underneath. Consequently the condition of the underside of the tiles is not known nor can we advise as to the method of fixing. Similarly the condition of the timber battens, which support the tiles, is not known. The surface of the tiles is prone to weathering and verges, ridges etc may need repair periodically. As noted previously the original slated roof covering has been replaced with concrete interlocking single lap tiles probably about years ago judging by the extent of weathering noted. Overall the extent of weathering noted was typical of age and the tiles appear to be in reasonable order with no evidence of significant distortion which can be a problem if the roof structure has not been strengthened to take the increased weight of the concrete tiles over the original slates. It must be appreciated that these tiles are likely to be heavier than the weight of the original roof covering and consequently the loads imposed on the roof framework may well have increased. Such additional loading can result in deflection of the roof framework and increased outward pressure on the upper parts of the external walls. In the case of the subject property we have noted under the following section that the roof structure has been adequately strengthened to take the increased loadings. Roof valleys are susceptible to blockage and deterioration. Leaks can result in timber defects and other damage. Such areas must be checked and overhauled regularly from long extension ladders. The condition of concealed valleys cannot be confirmed from ground level inspection. No external view of the valleys to the abutment of the rear projection roof to the rear roof slope was possible from ground level but internally we did note indications of damp ingress particularly below the internal right valley at lower level. This is likely to indicate that the valley lining in this area may be blocked or defective. We would suggest that as part of your refurbishment of the property that you have your contractor inspect the condition of the valleys and carry out any necessary repairs. 10 of 46

11 Slight moss and algae growth is present on the rear roof slopes. This can impede the run-off of rainwater, block gutters, damage roof coverings and cause water penetration, leading to rot and decay. It may be part of the cause of the problems noted to the valleys discussed above. Removal of moss should be undertaken regularly and consideration given to chemical treatment to prevent re-growth. Regular clearance of gutters is likely to be necessary if blockage and overflow are to be avoided. Mortar joints and coverings to hips, ridges and verges are prone to frost damage and weathering. Such areas can require repair periodically. Bedding of ridge and hip tiling to the rear apex section appears to be in good order. Half round ridge tiles have been provided to weather the joint between the roof covering of the subject and adjoining property, these are particularly prone to frost damage and subsequent leakage due to natural expansion and differential movement. Whilst no significant internal leakage was noted at the time of inspection we did note some minor cracking to the bedding at lower level to the front. This area should also be checked and repaired by your contractor to prevent future problems occurring. The roofing felt underneath the tiles should extend into the gutters at eaves level. Where this is not the case, or where the roofing felt is damaged, water running on top of the felt could cause rot to occur to eaves timbers. Joinery repairs and replacement felt will involve removal and replacement of the lower tiles. Timberwork to roof joinery is prone to rot and decay if the paint decoration or protection is not well maintained every 2 to 3 years. Limited inspection from ground level particularly to the rear outbuilding indicated the joinery in this location to be in fairly poor order and the paint decoration in need of urgent attention. Although the gutters have been replaced it is apparent that the original facia boards may not have been renewed where they have been damaged by the original gutters. It is likely that extensive replacement of timber will be required, and as part of this work the guttering will need to be removed and replaced. Please see later comments under the Rainwater Goods heading. In future they will require general overhaul and redecoration on a cyclic basis every 2-3 years if deterioration is to be avoided. The guttering does conceal areas of the roof joinery, we cannot confirm the condition where hidden. The roof space is unventilated and condensation problems could become apparent to the roof space, particularly on the underside of the roof covering. Consequently it is advised that ventilators be installed in accordance with current Building Regulations as part of the work discussed above. This is also particularly important if you intend to upgrade insulation at ceiling level in the roof space to modern recommendations. 11 of 46

12 The roof covering to the front bay roof is of bituminous felt which is today considered a short life material requiring regular renewal. Externally the felt is clearly old and there does not appear to be an adequate flashing to the abutment to the front wall, although internally there was no evidence of apparent leakage to the internal finishes. Overall this covering has reached the end of its useful life and we would suggest that as part of the roof works discussed you consider having this replaced with a long life material such as slate or plain tiles with a good quality Code 4 lead flashing to the front wall. As part of this work the roof structure should also be checked, insulation and ventilation improved. Roof Space A general inspection of the roof timbers has been made but we have not inspected all surfaces of every length of timber because of the style of construction and restricted access. An internal inspection was carried out via the trap hatch located over the hot water cylinder in the airing cupboard. Stored goods, insulation and any boarding/lining have not been moved limiting inspection. Loose boarding was noted and this requires careful access to prevent damage to the ceilings and possible injury. Boarding should be removed or firmly fixed. Internally we did note that the roof structure is of traditional cut and pitched timber construction and has been adequately strengthened by additional struts onto the spine partitions and a collar between the purlins. Whilst there is the normal minor splits and warping to the timbers typical of age and type, the roof structure is adequately upright and free from significant large scale distortion indicating that it is adequate to carry the increased weight of the concrete tiles. Each and every timber has not been inspected in the manner of a Timber Specialist report. Timbers were inspected on a random basis only. Inspection of the timbers, especially ceiling joists was limited by insulation or loose boarding which has not been moved. Timbers inspected on a random basis where accessible did indicate no evidence of active infestation. We cannot confirm freedom from defects in concealed areas. We would draw your attention to further comments under the Timber Defects heading later within this report. There is a layer of bituminous based under slating felt below the covering. This does hide the condition of the underside of the covering, battens and fixing arrangements. However, the felt where inspected on a random basis was in acceptable order for its age and type. 12 of 46

13 Below the valleys to the rear apex particularly to the internal right hand side we did note evidence of water and damp ingress which indicates problems with the valley linings as discussed under the external aspects. As part of the repair works the condition of the timber below should be checked for any decay which may have occurred in concealed areas. As noted previously the roof space is unventilated and condensation problems could occur, particularly to the underside of the roof covering if insulation levels are to be upgraded, resulting in possible rot and decay to the roof framework. Consequently it is advised that ventilators be installed in accordance with the latest Building Regulations as part of the work to the gutters and facia boards. It is important that insulation is kept clear from the eaves so that the roof space is properly ventilated so as to reduce risks of condensation, which could result in rot and decay. The loft space should be used for storage of lightweight items only. Due to the nature of the bay roof construction there is no accessible roof void. We cannot therefore comment on the construction, the condition of supporting timbers, standards of ventilation or levels of insulation. Timbers in the roof construction can be affected by decay if water penetration occurs due to lack of maintenance of the covering. Deterioration may occur before signs become apparent on visible surfaces. When renewing the covering as part of its limited life, it is advised that the underlying roof construction be checked and insulation/ventilation be upgraded to current expectations. Rainwater Goods Gutters and down pipes were inspected from ground level only. As it was not raining at the time of inspection it is not possible to confirm that the rain water installation his free from blockage, leakage etc., or that it is capable of coping with long periods of heavy rainfall. Rainwater goods must be maintained in a watertight condition otherwise external walls can be damaged and dampness could penetrate internally. Leaking, badly aligned and blocked gutters can cause eaves timbers and rafter feet to rot. Eaves timbers should be overhauled when redecorating, where leaks have occurred some replacement may be necessary. The condition of concealed eaves timbers is not known. Gutters, downpipes and gullies will need clearing out periodically. 13 of 46

14 The original cast iron gutters have been replaced in extruded aluminium ogee sectional items however we are concerned about the standard of installation work and that the original facia boards may not have been replaced. The original gutters would have been prone to leakage at joints and this would have resulted in localised decay. Similarly if the facia boards have not regularly redecorated they may have succumbed to decay. Examination of the gutter to the rear outbuilding certainly indicated poor fixture to the facia board and the view from ground level indicated evidence of leakage at joints to the adjoining properties gutters. We also noted evidence of weed growth and blockage to the rear gutter. Overall the standard of installation of these gutters appears to be poor and further work is required which is likely to involve removal and replacement of the facia boards in affected areas. We would suggest that you allow for a general overhaul of the gutters and facia boards as part of your refurbishment works. This work should also include the introduction of roof space ventilation as discussed previously. The exact method of rainwater disposal is unknown and can only be ascertained by a full test of the drainage system outside the scope of this report. In a property of this age surface water is likely to be connected into the combined foul drainage system to the rear elevation and empties over the pavement to the front via a lateral pipe to the right hand side of the garden. We did note that the lateral section of the pipe remains in the original cast iron and is concealed by paving slabs. This is likely to be heavily rusted and leaking below ground level and may also be partially blocked. As part of the work to the gutters it would be wise to renew this section so that rainwater from the terrace is taken away from the front wall and any risk of potential long term damage to the foundations. WALLS As foundations cannot be inspected without considerable excavation and possible damage to the property we cannot comment on their construction, depth or condition. Adequate insurance cover in respect of damage arising through subsidence, landslip or heave is essential. The depth and construction of foundations can only be confirmed by further opening up work. In a property of this age, it is considered likely that they would be shallow by modern Building Regulation standards. Inspection from ground level indicated no evidence of significant structural cracking, bulging or distortion to the main house, which would indicate that the foundations appear adequate to carry present imposed loads. There was typical slight historic differential movement at the junction between the rear wall of the bathroom and the outbuilding. The foundations to the outbuilding in a building of this age are likely to be 14 of 46

15 relatively shallow and certainly shallower than the back addition. As such slight differential movement can occur at the junction and this is clearly visible to the cracking over the side door and distortion to the opening. However within the limitations of the inspection and lack of access to the adjacent garden, the movement appears to be historic and the structure has settled as a whole. Assuming that this outbuilding is to be used for storage only and not part of an extension of the bathroom then all that would be required is simple metal restraint strapping to the junction and flexible infill to the cracking. As noted previously the external walls are of traditional 9 inch (225mm) solid masonry construction with a pebble dash rendered coating finished in masonry paint decoration. Where walls are of solid construction there is always the risk that dampness could penetrate through the wall from the exterior. Consequently it is important to well maintain the external surfaces of the walls and any facings. It is also important to adequately maintain roofs, together with rainwater goods, defects in which could result in a concentration of water running down the outer face of the wall. This will damage brickwork and allow water to reach the interior. Where solid walls are lined internally it should be appreciated that there is the risk that concealed parts of linings, timber battens especially, could be subject to decay in the event of damp penetration. Similarly, timbers built into solid external wall such as lintels, wall plates, bonding timbers and floor joists are also vulnerable. Damage to such timbers could adversely affect the stability of the buildings structure. Under certain conditions a dry rot outbreak could develop. As such a good level of external maintenance is essential in a house of this age and type. Where walls are rendered, we cannot comment on the condition of the wall behind. The rendered finish may conceal distortions or other defects. Any cracked and defective rendering should be repaired to prevent damp penetration and damage to the wall behind. Where masonry paint decoration is applied this will be subject to environmental deterioration and require cyclic renewal every 3 5 years if appearance is to be maintained. Localised infill and repair may prove necessary as part of preparation work to minor hairline cracking at daywork joints, around window and door openings, and at lower level. Use of good quality breathable masonry paint decoration is recommended to allow natural evaporation of moisture from the solid wall beneath. Non-breathable coatings can cause trapped moisture to cause damage to the render coating and the decoration to have a short life span. The render is taken down to ground level below the damp proof course. It is therefore prone to damp resulting in blown and damaged render at lower level. We would suggest that the render is cut off at DPC level and a bell lip formed a minimum of 6 inches (150mm) above ground level in accordance with current Building Regulations. 15 of 46

16 The external walls have been inspected from ground level from within the site area and other adjacent publically accessible areas. The render to the front elevation and rear wall is in fair condition for age and type with no evidence of significant large scale blown or damaged areas. The masonry paint decoration is weathered and in need of renewal. The render to the rear projection is badly damaged at lower level to the bathroom area due to the noted rising damp problems discussed later in this report. When the damp problems are rectified the external render will need to be replaced to match existing. It is important to properly maintain the junction between the external walls and door and window frames otherwise rain can penetrate causing concealed rot and decay to window frames together with damp staining and damage to plastered reveals. Any cracks or splits should be repaired and a good quality silicone sealant injected. We did note that at some time in the buildings life the stone sill to the kitchen window in the rear wall at ground level has been removed and the render extended over. This arrangement is considered unsuitable and could lead to damp ingress and localised damage to the render and wall below. We would suggest that a new sill is cast in situ to match the originals with a proper rainwater drip to the underside. This will protect the wall and render below from frost and damp damage. Where masonry, plaster or linings conceal support over openings, the type of lintel is not known nor can it be confirmed that lintels actually exist. Similarly we cannot confirm the adequacy or condition of any concealed lintels. In older buildings timber backing lintels are common behind the brick arches and these can be subject to rot and decay without signs being visually apparent. It is very important to well maintain the exterior in this respect. Where there are brick arches over openings, such arches are prone to cracking and defection due to stresses in narrow bands of brickwork. Where this occurs, additional support and repair can be required. In a building of this age it is likely that timber-backing lintels will be provided behind brick arches. The condition of concealed timber lintels is not known but it is most important to well maintain the exterior if decay and beetle attack is to be avoided. Visual inspection did indicate no evidence of significant distortion over openings which would indicate that the concealed support is adequate to carry imposed loads. As there is no access available it is not possible to comment on the construction or condition of the load-bearing beam above the bay window opening. Rainwater penetration can give rise to the development of rot in supporting timbers and careful maintenance is required if such problems are to be avoided. It is important to properly maintain external dressings, adjoining roofs and the walls as any defects could lead to water ingress resulting in damage. When the works are carried out to the bay roof the opportunity should be taken to ascertain the condition of the concealed beam and the bay roof structure. It is not unusual for slight 16 of 46

17 differential movement to occur between the beam and the wall resulting in external cracking, which could permit water ingress. In a building of this age it is likely that only a basic slated damp proof course would have been provided to the external walls of the main section of the house; no such damp course would have been provided to the original kitchen area as this would have been considered a wet area. The position of the DPC is generally concealed by the external render. Therefore, the height and position of the course cannot be confirmed. Slate DPC s are now considered substandard and are prone to cracking and breaking down resulting in isolated rising dampness. It should be considered of limited effectiveness and upgrading is advised. There are some indications that a remedial DPC may have been injected to the front wall and bay area but this is very difficult see due to the pebble dash render and subsequent reapplication of the masonry paint decoration. Normally we would advise you to check that there is an existing and valid guarantee but as this property is understood to be subject to repossession any such documents may have been lost but your legal adviser should check. As noted later under the main Dampness heading there did not appear to be a significant problem of rising damp to the main section but there is serious rising dampness to the bathroom area which will require treatment works. Externally the render has been damaged and requires replacement. Please see later comments. It is important to ensure that earth, paths etc are kept at least 150mm below the level of any damproof course and internal floor levels otherwise bridging could occur resulting in dampness internally. Ground levels to the rear were satisfactory but to the front they could benefit from lowering to the above recommendation. Through ventilation of floor timbers within the sub-floor void at ground level is essential otherwise dampness could accumulate and decay, even dry rot could develop. Air bricks should be kept clear and unobstructed. The sub-floor space may require clearance. No subfloor inspection has been carried out; we cannot confirm the condition of concealed timbers. As is typical, in a house of this age and type, the size and number of airbricks provided is considered insufficient by modern Building Regulation standards. As a precaution the subfloor void and timbers should be inspected and an estimate obtained for additional airbricks and any associated works, including floor timber repairs. Airbricks in the external walls should be ducted though to the sub-floor void. A check should be made to ensure this is the case. As part of your refurbishment works we would suggest that additional airbricks are installed in accordance with modern recommendations together with a precautionary sub floor inspection. 17 of 46

18 EXTERNAL JOINERY Hepburn & Associates Windows and doors have been inspected on a random basis. It has not been practical to inspect all parts of windows and, where applicable, no external inspection has been possible in respect of fixed lights, fanlight, stuck or locked windows above ground level. An inspection of such windows will only be practical from long builder s ladders, outside the scope of normal surveyor s equipment. All softwood joinery is prone to rot and decay within susceptible sill, frame and lower sash members if not well maintained on a cyclic basis every 2 to 3 years. Windows and doors have been inspected on a random basis only. As noted previously the windows have been replaced in double glazed Upvc units directly into brickwork surrounds. These were noted to be of basic quality only fitted with simple furnishings incorporating simple security devices. They appear to have been fitted to a reasonable contract standard but a number of the glazing panels were noted to have failed with internal misting noted. The double glazed units should be hermetically sealed but the effectiveness of the seal is not known. Under certain weather conditions mist or condensation may develop within the panes, if the seal is damaged or incomplete requiring replacement of the glazing panel, which can be expensive. Enquires should be made as to the existence of any transferable guarantee but again this may not be available due to the properties recent history. With regard to any replacement windows installed since January 1 st 2002, we must stress the importance that your legal advisor checks that the contractor who carried out the installation work is a member of FENSA (which is a Local Authority Building Regulation requirement) and that a FENSA Certificate has been issued. Alternatively, all work must have been inspected at the time of installation by the Local Authorities Building Control officer and an appropriate completion certificate issued. If neither can be proven to exist, then we are unable to guarantee the quality of any installation work carried out. We are unable to confirm that the glazing is of tempered or laminated safety glass. This can have significant implications from concerning personal safety. Building Regulations requires the use of safety glass in the vulnerable areas. You should be aware that escape in the event of fire could be extremely difficult from rooms where there is double-glazing with fixed or fan light windows only. If this is of concern, you may wish to give consideration to modifying or replacing windows, particularly to upper levels, as appropriate. It would be advisable to confirm that where security devices are fitted to doors and windows they comply with your insurance company requirements so that you are fully covered by 18 of 46

19 contents insurance. Upgrading where necessary to meet their requirements is strongly recommended in all cases. All entrance doors should be fitted with 5 level mortise locks. We do recommend that security devices be provided to all windows at ground and first floor levels and where in close association with pitched or flat roofed areas. The advice of the local Crime Prevention Officer can be obtained in this respect. The front and rear entrance doors are of similar age and type to the windows and warrant similar comments. The doors have adequate multi-locking arrangements but we did note that the lock and handle to the front door are loose and require attention. Overall the windows and doors are basic but considered serviceable following repair and overhaul work. They are considered acceptable for your intended letting use. The timber work to the outbuilding at the rear of the bathroom is in need of overhaul and repair together with some renewal particularly to the doors and lower parts of the frames. It is clear that the joinery in this area has not been well maintained in the past. Basic repair and redecoration would be wise as part of your refurbishment as any potential tenants or purchasers are likely to want to use this outbuilding for secure storage. Roof joinery requires frequent maintenance and redecoration. Our inspection from ground level was limited and these timbers, particularly where concealed by gutters can require overhaul and repair when attending to renewal of decoration. As discussed under the roof and gutters headings we are concerned that significant renewals of the facia boards will be required when the gutters are attended to. It is possible that filler is now covered by decorations and this may become apparent during preparatory work for redecoration. EXTERNAL DECORATIONS Upvc windows and doors are self coloured and do not require decoration but can benefit from cleaning down, adjustment and lubrication, to maintain appearance and improve performance. The external decorative condition of the remaining timber joinery and to the roof timbers is generally poor and redecoration/overhaul is now required. Repairs and isolated timber renewals may prove necessary to the roof joinery as part of preparation works. We would advise that you obtain estimates from experienced contractors prior to purchase. This should include a suitable contingency sum to cover repairs to any concealed rot and decay. 19 of 46

20 When attending to external protection careful preparation will be essential. Flaking material should be removed and all external joinery overhauled, repairing as necessary. The full extent of any decay will only become apparent when preparatory work is underway. CEILINGS, WALLS, PARTITIONS AND FINISHES Ceilings Ceilings had been inspected from floor level and no opening up work has been undertaken. We cannot comment upon the condition of the structure hidden behind ceilings and the type of material used can only be fully ascertained by further investigation. Original ceilings in a property of this age would be of lath and plaster but may have been subject to replacement or over cladding in plasterboard. Ceilings of lath and plaster are now of some age and it must be appreciated that with ceilings of this type, repairs and replacements can prove necessary at short notice. Such ceilings do therefore have a limited remaining life. Typically they will suffer from cracking and may require localised repair and infill when attending to redecoration. All plasterboard ceilings are prone to shrinkage cracking at board joints and junctions of walls and ceilings. They can require localised infill when attending to renewal of decorations. In the case of the subject property the ceilings to the upper level and front reception room appear to be original but have been covered by artex or other decoration concealing their condition. However from what could be seen from floor level they where in fair condition with only minor hairline cracking noted which will require infill and repair as part of preparation works prior to redecoration. Older artex prior to 1970 s may contain low percentages (5-10%) of asbestos fibre as a binder. Left in place this is not considered a health risk however the presence of such fibres can only be confirmed by a further test by a licensed specialist. Please see later comments under the Hazardous Materials heading. Within the bathroom and kitchen area we are however concerned about the quality of recent works to the ceilings. Within the bathroom area it appears that an attempt has been made to drop the ceiling however this is to a very poor DIY standard and the material used unsatisfactory for its location. As part of your refitting of the bathroom a new ceiling will be required. The original lath and plaster ceiling to the kitchen appears to have been overclad in plasterboard, again to a very poor DIY standard without adequate jointing and finish. We are 20 of 46

21 concerned that the original ceiling may have been in poor condition and loose from the substrate. In view of the apparent poor quality of the work it is considered unlikely that the new ceiling boards will have been properly fixed back onto the floor joists. If the underlying lath and plaster is inadequately bonded to the plaster laths there could be significant danger of collapse. As such we would suggest that your contractor carefully inspect and assess the condition of this ceiling; we suspect that complete replacement may prove to be required if a safe and secure ceiling is to be provided. This would certainly be advised if you intend to let the property as you could be personally liable for the tenant s safety. We are also concerned that the down lighters fitted to the kitchen ceiling have not been installed correctly and that required insulation and ventilation may not have been correctly installed. Please see our further comments under the Services heading regarding the electrical installation. Internal Walls & Partitions Internal walls and partitions had been inspected from floor level; concealed parts would need to be opened up in order to ascertain the materials used and their condition. We cannot comment upon the condition of the structure hidden behind panelling, dry lining and other applied finishes, including where applicable heavy furniture and fittings. Defects may become apparent when wallpaper and other finishes are removed. The internal spine partitions between the front and rear room areas is adequately upright and free from significant distortion which would suggest that it is adequately supported. Door openings are reasonably square for a building of this age and type. We would point out that we have carried out no opening up to confirm adequacy of support, particularly to upper level partitions. The partition within the bathroom area is of poor DIY quality and it is assumed that you will be removing this as part of the refitting of the bathroom. The internal wall plaster within the main section of the property is generally in fair order for the age of the building. Inevitably weak areas do exist in most rooms and with any property of this age repairs and renewals should be expected periodically, particularly when attending to redecoration. Repairs in the vicinity of doors, windows and heat sources are to be expected. Plaster work to the bathroom area is poor as is the quality of the ceramic tiling. It is considered that complete renewal will be required particularly at lower level were the plaster will have become contaminated with ground salts due to the rising dampness issues discussed under the main Dampness heading. 21 of 46

22 The life expectancy of any remaining lath and plaster wall linings must be considered limited, repairs and renewals should be allowed for periodically, especially when redecorating. Areas adjacent to window and door openings are particularly vulnerable. The condition of the concealed timbers, walls and fixings is not known. Dampness can cause decay and even dry rot to develop in concealed areas that may only be revealed by opening up. Good external repair is therefore essential. CHIMNEY BREASTS, FLUES AND FIREPLACES Chimney breasts have been visually inspected from floor level with no opening up carried out. It is strongly advised that flues be cleaned and checked for obstruction prior to use to minimise the risk of hazardous fumes entering the building. We cannot confirm the type, condition or existence of any flue lining. It is strongly advised that flues be cleaned and checked for obstruction prior to use to minimise the risk of hazardous fumes entering the building. We cannot confirm the type and condition of the flue lining. The chimney breasts to the right hand party wall are adequately upright and free from significant distortion which would suggest that they are adequately supported. No evidence of significant leakage or dampness was noted but the flues are open and have not been capped to the top. Where original fireplaces remain these will allow a reasonable degree of ventilation of the disused flues but a ventilation air brick would be wise to the chimney flue rising from the kitchen area. The fireplace within the lounge contains the original gas fired back boiler which as discussed under the Services heading it is assumed that you will be removing as part of upgrading the heating system. When the boiler unit has been removed the flue should also be properly vented. Where fireplace openings are filled in, it is important to allow through flow ventilation to the disused flue. Lack of adequate ventilation can lead to condensation and dampness within the chimney breast causing damage to brickwork and decorations etc. You should be aware that in a property of this age the flues are likely to be unlined or of limited effectiveness. Internal areas tend to deteriorate with age and if regular use is proposed then relining will be necessary. Flues which are used should be swept prior to use and regularly, at least once a year. Prior to use the condition of the flue should be checked by a specialist and if unlined or in poor order it may require relining to suit the proposed appliance. Lack of adequate lining can lead 22 of 46

23 to toxic fumes entering the building with risk of death due to asphyxiation. No evidence of significant leakage or staining was noted to the flue serving the boiler and gas appliance which indicates that there is likely to be an adequate flue liner but this cannot be confirmed without removal. Within the roof space there was noted to be some cracking to the line of the flue serving the fireplace in the kitchen. This would originally have been the main living room and therefore the flue would have been in regular or constant use. Thermal cracking is not unusual but does indicate that that this flue will not be properly sealed; if used smoke would enter the roof space. However the present use of this room means that this flue is no longer used. The brickwork to the corbelled section of the chimney breast although cracked does appear to be sound and free from loose sections. It would however be wise to ask your contractor to repoint and infill these cracks. Within the rear left hand corner of the third bedroom there would originally have been another chimney breast serving the copper flue from the original kitchen below (now the bathroom). As discussed previously the chimney stack and breast below have been removed and the roof extended over at the time of recovering of the roof. The chimney breast would have been corbelled out at ceiling level to the kitchen and not carried to ground level. At first floor level within the rear bedroom the removal of the chimney breast has not been carried out to an acceptable standard. The removal of the front of the breast has left a section of the rear wall which is only of single skin, four and a half inch thickness. This has been formed as a reveal to the corner of the room. The thickness of the wall is considered inadequate as regards thermal insulation and could lead to damp ingress and condensation issues. As noted to the Dampness heading, condensation has clearly been a significant issue within this area. The only acceptable means of rectification of this problem will be for the internal face to be fully bricked up or infilled with blockwork. FLOORS Floor coverings together with furnishings considerably restricted inspection of the floors. We could make a further inspection of the floors once the property has been cleared and vacated, subject to further instruction. Certainly it is advised that the opportunity be taken to ascertain the exact form of construction, the condition of floors and to overhaul as necessary. Localised repairs can be necessary when renewing floor coverings to your own taste. No floor coverings have been lifted and no under floor inspections carried out. 23 of 46

Example Building Condition Survey & Summary Report Address Address Address London

Example Building Condition Survey & Summary Report Address Address Address London Example Building Condition Survey & Summary Report on Address Address Address London Date 2016 Ref. no. London Building Surveyors Ltd, 20 Stanmore Road, London. E11 3BU Tel: 020 8257 5766 Mob: 07854 755

More information

Homebuyers Survey. Final Report. Mr Client. A Home, A Street, A Town. 3rd July 2014

Homebuyers Survey. Final Report. Mr Client. A Home, A Street, A Town. 3rd July 2014 Homebuyers Survey Final Report Mr Client A Home, A Street, A Town 3rd July 2014 Alpine Water Management Ltd Dorset House Regent Park Kingston Road Leatherhead KT22 7PL Tel: 0845 319 9 319 www.alpinedamp.co.uk

More information

REINSTATEMENT VALUATION

REINSTATEMENT VALUATION REINSTATEMENT VALUATION Marylebone, London W1U FOR Mr K Prepared by: INDEPENDENT CHARTERED SURVEYORS Marketing by: CONTENTS INTRODUCTION AND INSTRUCTION SYNOPSIS CONSTRUCTION SUMMARY EXECUTIVE SUMMARY

More information

MAINTENANCE PLAN Wing Village Hall, Morcott Road, Wing, Oakham LE15 8SA

MAINTENANCE PLAN Wing Village Hall, Morcott Road, Wing, Oakham LE15 8SA MAINTENANCE PLAN Roof Covering Roof slates Yearly Maintenance & Finishes 1 1, 8 & 13 Timber fascia and soffit boards Slates in good condition, some have been replaced during routine maintenance of roof.

More information

BUILDING SURVEYOR S INSPECTION REPORT OLD CO-OP BAKERY SUBSTATION - WEST CALDER FOR COMMUNITY DEVELOPMENT TRUST WEST CALDER.

BUILDING SURVEYOR S INSPECTION REPORT OLD CO-OP BAKERY SUBSTATION - WEST CALDER FOR COMMUNITY DEVELOPMENT TRUST WEST CALDER. BUILDING SURVEYOR S INSPECTION REPORT OF OLD CO-OP BAKERY SUBSTATION - WEST CALDER FOR COMMUNITY DEVELOPMENT TRUST WEST CALDER Prepared by SEPTEMBER 2017 Accessibility Statement In accordance with the

More information

SNAGGING REPORT. Plot 19 Snag Close Unfinished Avenue Oxford OX90 1AB. for. Mr T & Mrs N Sample

SNAGGING REPORT. Plot 19 Snag Close Unfinished Avenue Oxford OX90 1AB. for. Mr T & Mrs N Sample SNAGGING REPORT on Plot 19 Snag Close Unfinished Avenue Oxford OX90 1AB for Mr T & Mrs N Sample Prepared By: Marshalls Chartered Surveyors Rochester House The Grange Farm Eynsham Road Oxford OX2 9NH Tel:

More information

Stronsay Orkney KW17 2AT. Stronsay Orkney KW17 2AT. Date of inspection: 10 November Home Report

Stronsay Orkney KW17 2AT. Stronsay Orkney KW17 2AT. Date of inspection: 10 November Home Report JOHN S STOCKAN, BSc FRICS Chartered Surveyor Property address: Customer: Customer address: Holmsgarth Stronsay Orkney KW17 2AT Mr Ian & Mrs Arna Cooper Midgarth Stronsay Orkney KW17 2AT Date of inspection:

More information

TOFT HOUSE, THRESHFIELD Heritage Statement Feature: Window frames in South Elevation - windows 5,6,7,12,13 Description Softwood painted casements with side hung opening lights. Single glazed. Simply constructed

More information

SHS Building Consultants. Ph Job Details. Photograph shows the front elevation of the residence.

SHS Building Consultants. Ph Job Details. Photograph shows the front elevation of the residence. Practical Completion Report Inspection date 1 st January Client Mohit Vir Job Details Address Lot 3349 Limone street Aveley. W.A. Photograph shows the front elevation of the residence. DESCRIPTION OF THE

More information

XXXXXXXXXXX XXXXXXXX XXXXXXXXXXXXX XXXXXXXXXXX. Property address. Client's name. Date of inspection

XXXXXXXXXXX XXXXXXXX XXXXXXXXXXXXX XXXXXXXXXXX. Property address. Client's name. Date of inspection XXXXXXXXXXX XXXXXXXX Client's name XXXXXXXXXXXXX Date of inspection XXXXXXXXXXX 2 A Introduction to the report B About the inspection C Overall opinion and summary of the condition ratings D About the

More information

BUILDING INSPECTION. Mar 16, 2015 PROPERTY ADDRESS Killymoon Drive Hope Island, QLD 4212, Australia. 1 of 44

BUILDING INSPECTION. Mar 16, 2015 PROPERTY ADDRESS Killymoon Drive Hope Island, QLD 4212, Australia. 1 of 44 BUILDING INSPECTION Complies with Australian Standard AS 4349.1-2007 Inspection of Buildings Part 1: Pre-Purchase Inspections of Residential Buildings - Appendix C Mar 16, 2015 PROPERTY ADDRESS 1075 Killymoon

More information

Sample. Sample. Property address. Client s name. Date of inspection 1 st August 2014.

Sample. Sample. Property address. Client s name. Date of inspection 1 st August 2014. Client s name Date of inspection 1 st August 2014. 1 Contents A Introduction to the report B About the inspection C Summary of the condition ratings D About the property E Outside the property F Inside

More information

Survey level two: HomeBuyer report - Survey and Valuation

Survey level two: HomeBuyer report - Survey and Valuation RICS Home Surveys Survey level two: HomeBuyer report - Survey and Valuation Client s name Date of inspection 01/12/16. rics.org rics.org Contents A B C D E F G H I J K L Introduction to the report About

More information

Fireplace. Opening. Old. Opening up an old fireplace is like striking gold in your very own home.

Fireplace. Opening. Old. Opening up an old fireplace is like striking gold in your very own home. Opening up an Opening up an old fireplace is like striking gold in your very own home. In addition to a glowing, warmer, more welcoming living room, you are creating a much healthier and more invigorating

More information

Survey level two: HomeBuyer report - Survey and Valuation

Survey level two: HomeBuyer report - Survey and Valuation RICS Home Surveys Survey level two: HomeBuyer report - Survey and Valuation Client s name Mr A Date of inspection 9 th December 2016 rics.org rics.org Contents A B C D E F G H I J K L Introduction to the

More information

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ 08014 856-467-3626--- FAX 856-467-9260 Application for Certificate of Occupancy for Change of Occupancy Pursuant to Chapter 119 of the Township

More information

Refusal of a code compliance certificate for a building with a brick veneer and monolithic cladding system at 47 San Bernadino Drive, Henderson

Refusal of a code compliance certificate for a building with a brick veneer and monolithic cladding system at 47 San Bernadino Drive, Henderson Refusal of a code compliance certificate for a building with a brick veneer and monolithic cladding system at 47 San Bernadino Drive, Henderson 1. The dispute to be determined 1.1 This is a determination

More information

Healthy Homes Provisions of Lansing, Michigan Ordinances Extracted from by National Center for Healthy Housing

Healthy Homes Provisions of Lansing, Michigan Ordinances Extracted from  by National Center for Healthy Housing TITLE 6. HOUSING CHAPTER 1460. HOUSING AND PREMISES CODE Selected Provisions Related to Healthy Homes 1460.02. Applicability. (h) Historic Buildings. The provisions of this Code shall not be mandatory

More information

SAMPLE. Building Inspection Report. Inspection Date: Thu, 11 Feb 2016 Property Address:

SAMPLE. Building Inspection Report. Inspection Date: Thu, 11 Feb 2016 Property Address: Page 1 Building Inspection Report Inspection Date: Thu, 11 Feb 2016 Property Address: Page 2 Contents Section A Section B Section C Section D Section E Section F The parties Results of inspection - summary

More information

PRACTICAL COMPLETION REPORT

PRACTICAL COMPLETION REPORT PRACTICAL COMPLETION REPORT Report Commissioned By: Sample Practical Completion Report PO Box 355 HELENSVALE QLD 4212 Property Address: Sample Street SAMPLE REPORT QLD 0000 Date of Inspection: 8th July

More information

Storm Damage Assessment Report For: 1234 Example Street., Houston, TX 77002

Storm Damage Assessment Report For: 1234 Example Street., Houston, TX 77002 Storm Damage Assessment Report For: 1234 Example Street., Houston, TX 77002 Prepared For: Miriam Saliba nspection Date: 9/6/2017 Prepared By: Adam Wells TREC License # 21140 105 E Spreading Oaks Ave, Friendswood,

More information

CHAPTER 3: Modern Methods of Construction (MMC)

CHAPTER 3: Modern Methods of Construction (MMC) CONTENTS 3.1.1 INTRODUCTION 3.1.2 SUITABILITY OF SYSTEMS AND COMPONENTS 3.1.3 TYPES OF MODERN METHODS OF CONSTRUCTION (MMC) 3.1.4 SUITABILITY OF SYSTEMS TO MEET WARRANTY REQUIREMENTS 3.1.5 INSULATED CONCRETE

More information

INSPECT DIRECT. Web Page: THIS REPORT IS VALID FOR (6) MONTHS FROM THE DATE OF MOST RECENT INSPECTION.

INSPECT DIRECT. Web Page:  THIS REPORT IS VALID FOR (6) MONTHS FROM THE DATE OF MOST RECENT INSPECTION. INSPECT DIRECT Ph: 1300 133363 THIS REPORT IS VALID FOR (6) MONTHS FROM THE DATE OF MOST RECENT INSPECTION. REPORT ON DOMESTIC BUILDING WORK UNDER SECTION 137B OF THE BUILDING ACT 1993 (OWNER-BUILDER CONSTRUCTION)

More information

PROPERTY REPORT XXXX. Islington London. N1 XXX

PROPERTY REPORT XXXX. Islington London. N1 XXX PROPERTY REPORT Islington London. N1 XXX JOB REFERENCE: FOR Mr X Prepared by: INDEPENDENT CHARTERED SURVEYORS Marketing by: CONTENTS Introduction page 3 Synopsis page 4 Summary of Construction page 7 Executive

More information

PRE-PURCHASE STANDARD BUILDING REPORT

PRE-PURCHASE STANDARD BUILDING REPORT PRE-PURCHASE STANDARD BUILDING REPORT Report number: 1906172 Inspection date: 19 Jun 2017 Property address: Budgewoi Copyright Report Systems Australia Pty Ltd. This document is partly based on Standards

More information

RESIDENTIAL BUILDING SURVEY

RESIDENTIAL BUILDING SURVEY JOB REFERENCE: J????/HBR.RBS/RM//AW RESIDENTIAL BUILDING SURVEY OF A Modern Two Storey detached property in desirable location FOR Mr & Mrs 1930 s house Prepared by: INDEPENDENT CHARTERED SURVEYORS FOR

More information

SCHEDULE OF CONDITION. xxxxxxxxxxxxxxxxx xxxxxxxxxxxxx xxxxxxxxxxxx xxxxxxxxxxxxxxxx Wandsworth xxxxxxxxxxxxx

SCHEDULE OF CONDITION. xxxxxxxxxxxxxxxxx xxxxxxxxxxxxx xxxxxxxxxxxx xxxxxxxxxxxxxxxx Wandsworth xxxxxxxxxxxxx JOB REFERENCE: EX41535/SOC3/MH/MB3 SCHEDULE OF CONDITION xxxxxxxxxxxxxxxxx xxxxxxxxxxxxx xxxxxxxxxxxx xxxxxxxxxxxxxxxx Wandsworth xxxxxxxxxxxxx xxxxxxxxxxxxxxxx FOR xxxxxxxxxxxxxxx Prepared by: xxxxxxxxxxxxxxxxxxxxxxx

More information

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST This list is provided as a guide to help you understand the information that must be contained on the construction drawings. This list is not all-inclusive of all building codes but is used as a general

More information

Surveying the Surveyors

Surveying the Surveyors Abstract This research examines the perceived concern in the public arena about the quality of residential surveys and suggests a high rate of sub standard reporting within residential surveys. The Homebuyer

More information

Building Inspection Report

Building Inspection Report Building Inspection Report Sample Commercial Inspection Report Inspection Date: Prepared For: Prepared By: Professional Property Inspection Consultants 4857 Winterset Drive Columbus, OH 43220 (614) 459-5941

More information

LOOSE FILL ASBESTOS INSULATION

LOOSE FILL ASBESTOS INSULATION The following cards show how some common asbestos-containing materials can look. For more examples visit www.hse.gov.uk/asbestos-gallery LOOSE FILL ASBESTOS INSULATION Found in wall and floor cavities

More information

RESIDENTIAL BUILDING SURVEY

RESIDENTIAL BUILDING SURVEY RESIDENTIAL BUILDING SURVEY Milton Keynes, Buckinghamshire, MK17 FOR Mr N PREPARED BY Marketing at 1stAssociated 1 CONTENTS INTRODUCTION REPORT FORMAT SYNOPSIS EXECUTIVE SUMMARY AND SUMMARY UPON REFLECTION

More information

Rediflow Concrete Gas Flue System

Rediflow Concrete Gas Flue System Rediflow Concrete Gas Flue System Rediflow Concrete Gas Flue System Rediflow the complete gas flue block system Red Bank s range of Rediflow pre-cast concrete gas flue block system manufactured to BS EN

More information

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1% CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE EXAM ID: I1 80 multiple-choice questions 3-1/2-hour time limit Open book 01. GENERAL ADMINISTRATION 6% 0101. Project Administration 1% Verify that

More information

xxxxxxxxxxx, xxxxxx, Farnborough, GU14 xxx

xxxxxxxxxxx, xxxxxx, Farnborough, GU14 xxx JOB REFERENCE: xxx RESIDENTIAL BUILDING SURVEY xxxxxxxxxxx, xxxxxx, Farnborough, GU14 xxx FOR xxxxxxxxxxxxx Prepared by: x INDEPENDENT CHARTERED SURVEYORS Marketing by: xxxxxxxxx CONTENTS INTRODUCTION

More information

Residential Pre-handover Inspection Report

Residential Pre-handover Inspection Report , trading as Melbourne Property Inspections P/L 356 Collins Street MELBOURNE VIC 3000 Phone: (13)0088-6525 Mobile: 0414-184-686 Email: info@melbournepropertyinspectionscomau ABN: 95 477 052 614 Residential

More information

Property Condition Assessment

Property Condition Assessment Property Condition Assessment Pewaukee, WI 53072 Inspection Date: 1/6/15 Prepared For: Report Number: Prepared By: Shamrock Building Inspection Consultants LLC N29 W29951 Shel-Mar Dr. Pewaukee, WI 53072

More information

Corium Brick Rainscreen System Specifications

Corium Brick Rainscreen System Specifications CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated

More information

Inspection details. Subfloor. Subfloor. Before You Buy property inspection

Inspection details. Subfloor. Subfloor. Before You Buy property inspection Before You Buy 254 Richmond Rd, Auckland, 1011, Auckland info@beforeyoubuy.co.nz www.beforeyoubuy.co.nz 29th Sep, 2015 Inspection details Property owner Joe Bloggs Address 36 Bloggs st Date 03 Jul 2015

More information

October 26, 2017 Ref.: Newfoundland & Labrador English School District 95 Elizabeth Avenue St. John s, NL A1B 1R6

October 26, 2017 Ref.: Newfoundland & Labrador English School District 95 Elizabeth Avenue St. John s, NL A1B 1R6 October 26, 2017 Ref.: 351-1 Newfoundland & Labrador English School District 95 Elizabeth Avenue St. John s, NL A1B 1R6 Attention: Mr. Jim Sinnott Director of Facilities & Custodial Management Dear Sir:

More information

About asbestos. About asbestos

About asbestos. About asbestos About asbestos About asbestos Contact customer services on 01225 715 715 About asbestos This leaflet explains what asbestos is, how it is being managed in homes and what you can do to stay safe if it is

More information

Home Inspection Report Report Number: For The Property Located On:

Home Inspection Report Report Number: For The Property Located On: Home Inspection Report Report Number: 416-129 For The Property Located On: Some Place Dr Prepared For Exclusive Use By: John and Jane Doe Report Prepared By: Adam Duncan; License No.: 3533 Inspector Signature:

More information

Hill. Brockma Gill. Kearton. Home Farm. Sheep Wash. Langhorne House. Scale 1:1,250. Date 13/12/11. Brockma Gill East

Hill. Brockma Gill. Kearton. Home Farm. Sheep Wash. Langhorne House. Scale 1:1,250. Date 13/12/11. Brockma Gill East This drawing is the property of Niche Design Architects. Copyright is reserved Hill Low Top Brockma Gill NORTH.. Planning Issue 3 Red line boundary revised to include access. 3.. 05.0. Sheep Wash Kearton

More information

KEVIN BURNS HOMES PRACTICAL COMPLETION REPORT VISUAL BUILDING INSPECTION REPORT

KEVIN BURNS HOMES PRACTICAL COMPLETION REPORT VISUAL BUILDING INSPECTION REPORT KEVIN BURNS HOMES PRACTICAL COMPLETION REPORT VISUAL BUILDING INSPECTION REPORT No. 764 CLIENT: PROPERTY ADDRESS: Jindalee DATE: 25 November 2016 WEATHER: Fine ARRIVAL TIME: 8.15am DEPARTURE TIME: 10.30am

More information

Basement Renovation Guide For Residential Dwellings

Basement Renovation Guide For Residential Dwellings 1 Development Services Department Building Permit & Inspection Services Basement Renovation Guide For Residential Dwellings This document is a guide for home owners and does not cover all possible conditions.

More information

REPORT - on - XXXXXXXXXXX XXXXXXXXXX XXXXXXXX XXXXXXXX - for - XXXXXXXXXX

REPORT - on - XXXXXXXXXXX XXXXXXXXXX XXXXXXXX XXXXXXXX - for - XXXXXXXXXX REPORT - on - XXXXXXXXXXX XXXXXXXXXX XXXXXXXX XXXXXXXX - for - XXXXXXXXXX 1.00 INSTRUCTIONS 1.10 Scope of Instructions In accordance with the attached Terms & Conditions of Engagement dated XXXXXXXXXXX

More information

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017 SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE Amended 28 August 2017 BRANZ Appraisals Technical Assessments of products for building and construction. Sika (NZ) Ltd PO Box 19 192 Avondale Auckland 1746

More information

In Depth Home Inspection LLC Report # Doe STRUCTURAL PESTS & DRY ROT INSPECTION REPORT

In Depth Home Inspection LLC Report # Doe STRUCTURAL PESTS & DRY ROT INSPECTION REPORT ADDRESS OF 123 Main Ave NE DATE OF INSPECTION PROPERTY Salem OR 97301 Feb 1, 2010 INSPECTED Inspection ordered by John and Jane Doe Report sent to John and Jane Doe Owner's Name & Address John and Jane

More information

These installation instructions cover the installation and operation of Jetmaster Inset and Freestanding Barbecues

These installation instructions cover the installation and operation of Jetmaster Inset and Freestanding Barbecues These installation instructions cover the installation and operation of Jetmaster Inset and Freestanding Barbecues ADDRESS Jetmaster Fires Ltd Unit 2, Peacock Trading Estate Goodwood Road Eastleigh Hampshire`

More information

Construction Studies Theory - Higher Level

Construction Studies Theory - Higher Level 2015. M76 Coimisiún na Scrúduithe Stáit State Examinations Commission Leaving Certificate Examination, 2015 Construction Studies Theory - Higher Level (300 marks) Friday, 12 June Afternoon, 2:00 to 5:00

More information

SEI APPENDIX 7.4 LISTED BUILDINGS BACKGROUND DATA

SEI APPENDIX 7.4 LISTED BUILDINGS BACKGROUND DATA SEI APPENDIX 7.4 LISTED BUILDINGS BACKGROUND DATA BLAEN-NANT-DU CWM YR HOB BLAEN-NANT-DU Blaen-nant-du, including attached farm ranges Street Name and Number:, Listed Building Reference: 82989 Grade: II

More information

InterNACHI. Advanced Inspection of Crawlspaces for home inspectors

InterNACHI. Advanced Inspection of Crawlspaces for home inspectors CRAWLSPACE INACCESSIBLE Crawlspace conditions which in the Inspector s opinion posed a personal safety hazard limited examination of the crawlspace to only those home systems and their components visible

More information

Middle Barn, Front Street, Chedzoy, Nr. Bridgwater TA7 8RE

Middle Barn, Front Street, Chedzoy, Nr. Bridgwater TA7 8RE Middle Barn, Front Street, Chedzoy, Nr. Bridgwater TA7 8RE Highly appointed converted stone barn with substantial garden and double garage. Grand entrance hall, substantial 28' lounge/diner, re-fitted

More information

INDICATIVE FEASIBILITY BUDGET (RIBA STAGE 1) for ST JAMES'S CHURCH : WEYBRIDGE SURREY. June 2016

INDICATIVE FEASIBILITY BUDGET (RIBA STAGE 1) for ST JAMES'S CHURCH : WEYBRIDGE SURREY. June 2016 INDICATIVE FEASIBILITY BUDGET (RIBA STAGE 1) for INTERNAL REPAIRS AND REDECORATIONS OF THE CHURCH HALL at ST JAMES'S CHURCH : WEYBRIDGE SURREY June 2016 SAWYER & FISHER (EPSOM) LTD THOMAS FORD & PARTNERS

More information

BARING HEAD s Keepers Houses. Building Inspection Report - BARING HEAD PROJECT

BARING HEAD s Keepers Houses. Building Inspection Report - BARING HEAD PROJECT Building Inspection Report - BARING HEAD s Keepers Houses Inspection Date: 02/12/2010 Prepared for: Greater Wellington Regional Council Department of Conservation Prepared by: HCC Building Team Weather

More information

Conservatory Roof Conversion System. Transform your conservatory into a comfortable living space

Conservatory Roof Conversion System. Transform your conservatory into a comfortable living space Conservatory Roof Conversion System Transform your conservatory into a comfortable living space The market-leading Guardian Warm Roof is a revolutionary step forward in home improvement a high performance,

More information

Cavity Wall Ties. Survey & Repair Summary. Brief History

Cavity Wall Ties. Survey & Repair Summary. Brief History Cavity Wall Ties Survey & Repair Summary Brief History Cavity wall construction has existed since the early nineteenth century and became the norm from the late 1800s to the present day. Principal advantages

More information

ASBESTOS YOUR QUICK GUIDE DON T BE AN EASY TARGET

ASBESTOS YOUR QUICK GUIDE DON T BE AN EASY TARGET EP IDE KE GU IS TH ASBESTOS YOUR QUICK GUIDE DON T BE AN EASY TARGET Asbestos could be in the house or building you are working on right now. Left alone, it isn t dangerous. However, once disturbed, tiny

More information

RESIDENTIAL BUILDING SURVEY

RESIDENTIAL BUILDING SURVEY JOB REFERENCE: xxxxxxxxxx RESIDENTIAL BUILDING SURVEY xxxxxxxx, Walworth, London SE17 xxxxx FOR xxxxxxxxxxx Prepared by: xxxxxxxxxx INDEPENDENT CHARTERED SURVEYORS Marketing by: CONTENTS INTRODUCTION REPORT

More information

Premier Inn, Wilson Street, Middlesbrough, TS1 1AE. Site progress report. February 2017

Premier Inn, Wilson Street, Middlesbrough, TS1 1AE. Site progress report. February 2017 Premier Inn, Wilson Street, Middlesbrough, TS1 1AE Site progress report February 2017 Site set up Currently 4 weeks in to the build the site has been cleared and hoardings have been erected. Welfare cabins

More information

TECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9

TECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9 MARKINGWALLING OF SAFETY GLASS SPANDREL CURTAIN PANELS FORMED TO COLDFROM ROOFS STACKED WINDOW 7.2 /25 January ARRANGEMENTS (First Issue) XXXX EXXON QUESTION Which factors should be taken into account

More information

CABONNE COUNCIL DEVELOPMENT CONTROL PLAN NO. 15 RELOCATABLE AND TRANSPORTABLE HOMES

CABONNE COUNCIL DEVELOPMENT CONTROL PLAN NO. 15 RELOCATABLE AND TRANSPORTABLE HOMES CABONNE COUNCIL DEVELOPMENT CONTROL PLAN NO. 15 RELOCATABLE AND TRANSPORTABLE HOMES As approved by Council at the meeting of 20 June 2005 Came into effect on 14 July 2005 I, G. L. P. Fleming, General Manager,

More information

SCHEDULE OF CONDITION. xxxxxxxxxxxx, xxxxxxxxxxxx, xxxxxxxxxxx, Leeds, LS15 xxx

SCHEDULE OF CONDITION. xxxxxxxxxxxx, xxxxxxxxxxxx, xxxxxxxxxxx, Leeds, LS15 xxx JOB REFERENCE: xxxxxxx SCHEDULE OF CONDITION xxxxxxxxxxxx, xxxxxxxxxxxx, xxxxxxxxxxx, Leeds, LS15 xxx Date xxxxxxxxxxxx FOR Mrs xxxxxxxx Prepared by INDEPENDENT CHARTERED SURVEYORS Marketing by: , xxxxxxxxxxxx,

More information

RELIANCE HOUSE 20 WATER STREET LIVERPOOL L2 8UQ

RELIANCE HOUSE 20 WATER STREET LIVERPOOL L2 8UQ RELIANCE HOUSE 20 WATER STREET LIVERPOOL L2 8UQ EXTENSION & CONVERSION PROJECT TO CREATE 139 APARTMENTS INVESTORS REPORT 01 22 nd NOVEMBER 2017 Prepared By: G.Moody BSc Hons MRICS C.Build E MCABE Ref:

More information

MCMI RIBA MRICS MBIFM FCIOB

MCMI RIBA MRICS MBIFM FCIOB Building Maintenance Brian Wood, DipArch MCMI RIBA MRICS MBIFM FCIOB Department of Real Estate and Construction School of the Built Environment Oxford Brookes University )WILEY-BLACKWELL A John Wiley &

More information

Keep your home. FREE from DAMP, CONDENSATION and MOULD

Keep your home. FREE from DAMP, CONDENSATION and MOULD Keep your home FREE from DAMP, CONDENSATION and MOULD 1 2 This booklet gives some basic information about the different types of dampness that may affect your home. Condensation is probably the biggest

More information

Continuing Certificate of Occupancy Pre-Inspection Checklist

Continuing Certificate of Occupancy Pre-Inspection Checklist Pre-Inspection Checklist INTRODUCTION: This pre-inspection checklist has been produced to assist you in preparing for a Continuing Certificate of Occupancy (CCO) inspection. The inspection criteria and

More information

CHAPTER 7: Superstructure

CHAPTER 7: Superstructure CONTENTS 7.1 EXTERNAL MASONRY WALLS 7.2 STEEL FRAME 7.3 TIMBER FRAME 7.4 WINDOWS AND DOORS 7.5 CHIMNEYS 7.6 BALCONIES 7.7 CLADDING 7.8 ROOF STRUCTURE 7.9 ROOF COVERINGS - TRADITIONAL SLATE AND TILES 7.10

More information

Chapter 2 Understanding The Problem

Chapter 2 Understanding The Problem Chapter 2 Understanding The Problem What Causes Most Of The Problems With Stucco? EIFS was originally intended to seal and insulate the exterior of the home from the elements. Problems occur when poorly

More information

Civil Engineering Construction Chapter 5

Civil Engineering Construction Chapter 5 Civil Engineering Construction Chapter 5 Introduction to Floor Dr Mohamad Syazli Fathi Department of Civil Engineering UTM RAZAK School of Engineering & Advanced Technology UTM International Campus August

More information

5 Garon Terrace Nantymoel Bridgend. CF32 7RH 76,500

5 Garon Terrace Nantymoel Bridgend. CF32 7RH 76,500 5 Garon Terrace Nantymoel Bridgend. CF32 7RH 76,500 THREE BEDROOM MID TERRACE SUPERB VALLEY VIEWS TWO RECEPTION ROOMS KITCHEN/COMBI BOILER TERRACED LAWNED GARDEN VEHICLE/HARDSTANDING/EPC=D Ref: PRA10637

More information

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco

More information

REPAIR RESPONSIBILITY. Who does what and when?

REPAIR RESPONSIBILITY. Who does what and when? REPAIR RESPONSIBILITY Who does what and when? We will maintain our homes to a good state of repair and meet our legal obligations, as well as our customers expectations. The terms of each tenant s tenancy

More information

Warmer Roof. Transforming conservatory roofs. WarmerRoof

Warmer Roof. Transforming conservatory roofs. WarmerRoof Warmer Roof Transforming conservatory roofs WarmerRoof the easy way to transform your conservatory into a room you can use and enjoy all year round WarmerRoof what is the Warmer Roof? a highly insulated,

More information

Determination 2015/048

Determination 2015/048 Determination 2015/048 Regarding the compliance with the Building Code of proposed retrofitted urea formaldehyde foam wall insulation in a 60-year-old weatherboard clad house at 26 Porritt Street, Paeroa

More information

Historic Scodand Board Meeting 26 th April 2007 HSB 08/ 07

Historic Scodand Board Meeting 26 th April 2007 HSB 08/ 07 Historic Scodand Board Meeting 26 th April 2007 HSB 08/ 07 Appendix M - Tabulation of proposed works, by room 24 Tabulation of proposed works, by room. Room Room Name Analysis of significant elements In

More information

RESIDENTIAL BUILDING SURVEY

RESIDENTIAL BUILDING SURVEY JOB REFERENCE: XXXX RESIDENTIAL BUILDING SURVEY XXXX Cambridge. CB4. FOR Mr X Prepared by: INDEPENDENT CHARTERED SURVEYORS Marketing by: CONTENTS INTRODUCTION REPORT FORMAT SYNOPSIS EXECUTIVE SUMMARY SUMMARY

More information

One and Two Family Additions

One and Two Family Additions One and Two Family Additions An addition to a house, duplex, garage, or an accessory structure requires a building permit prior to performing any construction. Building Department & Permit Office Mon-Fri

More information

ROOFS AND ROOFING. Performance, diagnosis, maintenance, repair and the avoidance of defects. H W Harrison, P M Trotman and G K Saunders

ROOFS AND ROOFING. Performance, diagnosis, maintenance, repair and the avoidance of defects. H W Harrison, P M Trotman and G K Saunders BRE Building Elements series ROOFS AND ROOFING Performance, diagnosis, maintenance, repair and the avoidance of defects THIRD EDITION H W Harrison, P M Trotman and G K Saunders BRE Building Elements series

More information

CB04. Outback House. Case Study. Creative Spaces Australia. by Casey Brown Architecture

CB04. Outback House. Case Study. Creative Spaces Australia. by Casey Brown Architecture CB04 Case Study Outback House by Casey Brown Architecture Creative Spaces Australia E : info@creativespacesaustralia.com.au www.creativespacesaustralia.com.au Introduction Inspired by the big sheds of

More information

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products. GypLyner GypLyner Metal framed wall lining system All our systems are covered by SpecSure when using genuine Gyproc and Isover products Linings GypLyner GypLyner is a cost-effective, virtually independent

More information

Papers. Truss rafter roof support: How risk from inherent building defects is being exacerbated by changing climatic conditions

Papers. Truss rafter roof support: How risk from inherent building defects is being exacerbated by changing climatic conditions Papers Truss rafter roof support: How risk from inherent building defects is being exacerbated by changing climatic conditions Received (in revised form): 5th May, 2005 Alan Holmes is a chartered building

More information

Insulation requirements

Insulation requirements Insulation requirements www.tenancy.govt.nz 0800 TENANCY (0800 836 262) First edition, reprinted in 2015 by Ministry of Business, Innovation and Employment PO Box 10-729 Wellington New Zealand This document

More information

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW.

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW. AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW www.stromatech.com AIR BARRIER DESIGN PRINCIPLES Building Regulations Approved Document Parts L1A & L2A currently requires that new buildings have to achieve a

More information

Dunbrik A1 Concrete Flue Liners

Dunbrik A1 Concrete Flue Liners Dunbrik A1 Concrete Flue Liners System Guide Firebelly stove FB2 woodburner in pewter domestic flue & chimney systems Certificate No.FM24104 Benefits of a Chimney A chimney adds appeal to a house A real

More information

Home Condition Report Data model Version 8 - dated 1 st December 2004

Home Condition Report Data model Version 8 - dated 1 st December 2004 Home Condition Report Data model Version 8 - dated 1 st December 2004 This version of the Home Condition Report contains the amendments agreed by the Home Condition Report and Regulations Working Groups,

More information

60 years. of progressive development

60 years. of progressive development Dencroft has been providing a wide range of sectional buildings for over 60 years, making us one of the most experienced designers and manufacturers of quality garages in the UK. Innovation has played

More information

Exhibit A Declaration of Restrictions Development and Design Standards For Ridge Park Estates

Exhibit A Declaration of Restrictions Development and Design Standards For Ridge Park Estates Exhibit A Declaration of Restrictions Development and Design Standards For Ridge Park Estates Spokane County, Washington For All Property Owners The following Development and Design Standards shall be

More information

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS St. Louis County Department of Public Works Division of Code Enforcement HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS This guide is intended to provide the homeowner or contractor with the

More information

SOL UTIONS LIVING SOLUTIONS LIVING SOLUTIONS

SOL UTIONS LIVING SOLUTIONS LIVING SOLUTIONS Buyer s Guide HOMES 1300 985 110 LIVING SUPPORT SOLUTIONS 2 BCDS0868 Contents Just imagine the space you can create 4 More reasons to choose SmartSpace 8 SmartSpace Project Planner 9 Design your SmartSpace

More information

Garage Conversion - Between and Under Joist Applications

Garage Conversion - Between and Under Joist Applications Issue 1, August 2013 CI/SfB (2 -) Rn7 (M2) Garage Conversion - Between and Under Joist Applications Flat Roof Insulation Introduction Celotex is the brand leading manufacturer of PIR insulation boards,

More information

MOLD INSPECTION REPORT Block Home Inspections LLC

MOLD INSPECTION REPORT Block Home Inspections LLC Block Home Inspections LLC David Block - 913-220-7762 MOLD INSPECTION REPORT Block Home Inspections LLC David M. Block Certified Mold Inspector #CMI-06-2024 INSPECTION AGREEMENT Mold screening is intended

More information

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit: TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION 355-7575 Ext. 395 Needed to Obtain Permit: 1. Building Permit Application, and/or residential plumbing permit application, as applicable, to be

More information

Specialists in Acoustic Flooring and House to Flat Conversions

Specialists in Acoustic Flooring and House to Flat Conversions Sound Solution Consultants Ltd Po Box 755 Capel St Mary Ipswich Suffolk IP9 2WF Tel No: 0845 5212096 Fax No: 0845 5212097 Email: mpconsultservice@aol.com Specialists in Acoustic Flooring and House to Flat

More information

HANDOVER REPORT. Property Address: XXXXX XXXXX. Report Number: Inspection Date & Time: XXXXX

HANDOVER REPORT. Property Address: XXXXX XXXXX. Report Number: Inspection Date & Time: XXXXX HANDOVER REPORT Property Address: Report Number: XXXXX XXXXX XXXXX XXXXX Inspection Date & Time: XXXXX Report Systems Australia Pty Ltd & Australian Building Inspection Services Pty Ltd Form: Feb 2011

More information

Section 10. Rendering, Plasterboard & Fibre Cement Sheeting

Section 10. Rendering, Plasterboard & Fibre Cement Sheeting MARKETING PROPERTY-PROJECT SERVICES STD - D905 VOLUME 2 Service Station Construction SPECIFICATION Section 10 Rendering, Plasterboard & Fibre Cement Sheeting Index 10.1 Extent of Work 10.2 Rev 07.8 General

More information

Rooftrim Pre-Course Training Guide

Rooftrim Pre-Course Training Guide Rooftrim Pre-Course Training Guide ML0961 V1 May 13 Contents Section 1 Rooftrim 4 Chapter 1 - Rooftrim Range 4 Chapter 2 - Ancillary Products 6 Chapter 3 - Colour Finishes - PVC-U 7 Chapter 4 - Heritage

More information

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork Insulation CI/SfB (21.9) Rn7 M2 First Issue May 2017 e with retaining clip TW50 STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY 25 mm / 50 mm residual cavity Kingspan Thermawall TW50 Outer

More information

Historic Preservation Commission

Historic Preservation Commission Historic Preservation Commission APPLICATION F CERTIFICATE OF APPROPRIATENESS PROPERTY ADDRESS: DATE: APPLICANT S NAME: APPLICANT S MAILING ADDRESS: CITY:. ZIP: TELEPHONE # HOME/CELL: WK: EMAIL: PROPERTY

More information

Reference Designs for Standard Classroom Upgrade FORMULA BLOCK

Reference Designs for Standard Classroom Upgrade FORMULA BLOCK Reference Designs for Standard Classroom Upgrade FORMULA BLOCK Contents 1 Introduction... 3 1.1 Reference designs... 3 1.2 Benefits... 3 1.3 Interaction with the Designing Quality Learning Spaces (DQLS)...

More information